Air conditioner Daikin FTXR-E Ururu Sarara Technical Data

Air Conditioning
Technical Data
Wall mounted unit
EEDEN13-100
FTXR-E
• Indoor Unit • Wall mounted unit • FTXR-E
TABLE OF CONTENTS
FTXR-E
1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Options
4
............................................................... 5
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Dimensional Drawings
5
..................................................... 7
Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Piping Diagrams
7
............................................... 6
Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Centre of Gravity
6
..................................................... 8
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Wiring Diagrams - Single Phase
8
3
4
.................................... 9
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Split - Sky Air • Indoor Unit
10
11
1
• Indoor Unit • Wall mounted unit • FTXR-E
1
ket Sti n uU - o mr tE o - i ol R l dl X pnaT •ISFW
•
Features
URURU humidification: maintains a comfortable humidity level
without any separate water supply
•
Good design award: unique evaluation criterion for industrial design
in Japan
SARARA dehumidification: maintains a comfortable and fresh indoor
environment by removing moisture from the air without lowering the
temperature
•
Whisper quiet operation: down to 23dBA sound pressure level
•
Online controller (optional): control your indoor unit from any location
via smartphone, laptop, pc, tablet or touch screen
•
Other features: moisturizing operation mode, breeze cooling air flow,
comfort sleep operation, mould shock operation
1
•
Powerful ventilation refreshes the room within 2 hours
1
•
Powerful air purification increases indoor air quality with Daikin Flash
Streamer technology
5 steps
2
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXR-E
2
Specifications
2-1 Technical Specifications
Power input - 50Hz
FTXR28E
FTXR42E
FTXR50E
0.035
0.040
0.035
0.040
Cooling
Nom.
kW
0.030
Heating
Nom.
kW
0.030
Casing
Colour
White
Dimensions
Unit
Height/Width/Depth
Packed unit
Height/Width/Depth
mm
305/890/209
1
mm
378/956/280
kg
14
2
Weight
Unit
Packed unit
kg
18
Heat exchanger
Length
mm
700
mm
1.2 / 1.6
Rows
Quantity
2/1
Fin pitch
Stages
Quantity
20 / 12
Tube type
ø6.35 Hi-XU
Fin
Fan
Type
Multi slit fin
Type
Cross flow fan (with saw edge)
Air flow rate
Cooling
Heating
High
m³/min
11.1
12.4
cfm
392
438
470
Nom.
m³/min
11.1
12.4
13.3
cfm
392
438
470
Low
m³/min
6.5
6.8
7.3
Silent operation
cfm
m³/min
230
5.7
240
6.0
258
6.5
cfm
201
212
230
m³/min
12.4
12.9
14.0
cfm
438
456
494
Nom.
m³/min
9.8
10.2
11.1
cfm
346
360
392
Low
m³/min
7.3
7.7
8.3
cfm
258
272
239
Sound pressure level
m³/min
6.5
6.8
7.3
cfm
230
240
258
Model
KFD-280-57-8A
Speed
Sound power level
Steps
5 + silent, + auto
Cooling
High/Medium/Low/
Silent operation
rpm
1,190/990/790/720
1,300/1,060/820/750
1,380/1,120/860/790
Heating
High/Medium/Low/
Silent operation
rpm
1,300/1,080/860/790
1,340/1,110/890/820
1,440/1,190/950/860
Output
High
W
Cooling
Nom.
dBA
55
57
59
Heating
Nom.
dBA
57
58
60
Cooling
High/Nom./Low/Silent operation
dBA
39/33/26/23
42/35/27/24
44/37/29/26
Heating
Super high/High/Nom./Low/Silent dBA
operation
-/41/35/28/25
-/42/36/29/26
-/44/38/31/28
Refrigerant
Type
Piping connections
Heat insulation
57
R-410A
Both liquid and gas pipes
Temperature control
Microcomputer control
Air direction control
Right, Left, Horizontal, Downward
Air filter
13.3
High
Silent operation
Fan motor
3
Type
Removable / washable / mildew proof
Standard Accessories : Batteries; Quantity : 2;
Standard Accessories : Deodorising filter for streamer; Quantity : 1;
Standard Accessories : Installation manual; Quantity : 1;
Standard Accessories : Fixing screw for indoor unit; Quantity : 2;
Standard Accessories : Titanium apatite photocatalytic air purification filter; Quantity : 1;
Standard Accessories : Air Supply filter frame; Quantity : 1;
Standard Accessories : Air supply filter; Quantity : 1;
Standard Accessories : Fixing screw for drain hose; Quantity : 1;
Standard Accessories : Remote control holder; Quantity : 1;
Standard Accessories : Infrared remote control (ARC447A1); Quantity : 1;
Standard Accessories : Operation manual; Quantity : 1;
• Split - Sky Air • Indoor Unit
3
• Indoor Unit • Wall mounted unit • FTXR-E
2
Specifications
2-2 Electrical Specifications
Power supply
FTXR28E
Name
2
Current
1~
Frequency
Hz
50
Voltage
V
220-240
Nominal running
Cooling
current (RLA) - 50Hz Heating
A
0.14
0.16
0.19
A
0.14
0.16
0.19
Wiring connections - 50Hz For power supply
Remark
3 for power supply, 4 for interunit wiring (Earth wire included)
Notes
(1) SL: The silent fan level of the air flow rate setting
(2) When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.
4
FTXR50E
V1
Phase
1
FTXR42E
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXR-E
3
Options
3-1
Options
3
1
3
• Split - Sky Air • Indoor Unit
5
• Indoor Unit • Wall mounted unit • FTXR-E
4
Dimensional drawings
4-1
Dimensional Drawings
1
4
6
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXR-E
5
Centre of gravity
5-1
Centre of Gravity
3
1
5
• Split - Sky Air • Indoor Unit
7
• Indoor Unit • Wall mounted unit • FTXR-E
6
Piping diagrams
6-1
Piping Diagrams
1
6
8
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXR-E
7
Wiring diagrams
7-1
Wiring Diagrams - Single Phase
3
∼
1
7
∼
∼
• Split - Sky Air • Indoor Unit
9
• Indoor Unit • Wall mounted unit • FTXR-E
8
Sound data
8-1
Sound Pressure Spectrum - Cooling
1
8
10
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXR-E
8
Sound data
8-2
Sound Pressure Spectrum - Heating
3
1
8
• Split - Sky Air • Indoor Unit
11
BARCODE
Daikin products are distributed by:
EEDEN13-100 • 02/13 • Copyright Daikin
The present publication supersedes EEDEN12-100
The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.
has compiled the content of this leaflet to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products
and services presented therein. Specifications are subject to change
without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.