Security Brands 16-T1 Ascent T1 Quick Start Guide
PDF
Download
Document
Advertisement
Advertisement
1 of 4 Q U I C K S TA R T G U I D E Model 16-T1 1 Carefully unpack box and make sure you have all items shown here. (Screwdriver not shown) Ascent Unit 12-V AC/DC Adapter (PS-12DC1) Key Carriage Bolt ( 4x ) What’s what? Important components labeled Unit shown with front panel fully open. Internal wiring not shown for clarity. Hex Nut ( 4x ) Antenna Cables r I M PO R TA NT ! Ascent WILL NOT WORK until the activation process is COMPLETE! Follow the Activation Guide or call Summit Control at (972) 474-6422 to activate your unit. S T OP ! Power Terminals This is a cellular accessory for a gate/door, so an uninterrupted cellular connection CANNOT BE GUARANTEED. For wiring to compatible AC/DC power source An emergency egress or primary entry mechanism SHOULD ALWAYS BE USED (transmitter, fire box, mechanical release). SIM Card Consult with your dealer, distributor, and/or system designer for more information. Relay Status LEDs W A R NING! AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH! Relay is active when lit. 2 Unlock and open front panel of unit for wiring and setup. ALWAYS CHECK that the GATE PATH IS CLEAR BEFORE OPERATING! Connection Terminals For wiring to all external devices including gate operator or door opener REVERSING or other SAFETY DEVICES SHOULD ALWAYS BE USED! C A U TIO N ! Please use all four screws when mounting unit to pedestal. Leave “hockey puck” antenna in place, even if using extension. Seal any holes or gaps created in unit enclosure. Failure to follow instructions can damage unit! Continued on next page... 2 of 4 Q U I C K S TA R T G U I D E 3 Connect wires Model 16-T1 Ascent Connection Terminals Feed wires through back of unit and connect as shown using included screwdriver. STATUS DIGITAL INPUTS EVENT RELAY B RELAY A J5 J4 Gate Operator / Door Opener 12–24 VAC/DC POWER Excessive force can damage unit. J7 12–24 VAC/DC J8 J9 J6 Before going forward, double check wiring and ensure unit has power! For additional wiring options, see Page 3. © 2021 Security Brands, Inc. All rights reserved. 4 12-V AC/DC Adapter (Model PS-12DC1 included) The GROUND terminal is optional unless required by local code(s). If using, please connect to earth ground or equivalent. Close and lock front panel. Relay B can be wired to a second device in the same manner. Consult gate operator or door opener manual for exact connections. Terminals vary widely across manufacturers and models. CLOSE STOP OPEN COM REVERSE LOOP COM FREE EXIT COM RADIO COM NEG. (–) POS. (+) N/C COM N/O N/C COM N/O GND N/O GND #2 OR Third-Party 12–24-VAC/DC Power Source S T OP ! GND If plugging into duplex outlet, remove screw from outlet plate, and secure with included screw. + – #1 OPEN NEG. (–) POS. (+) J3 CLOSE Ascent Power Terminals GND POWER Additional wiring diagrams can be found on Page 3. C A U TIO N ! If you will not be using the 12-V AC/DC adapter, please go to Page 4 and follow the procedure, Using a Third-Party Power Source. Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage unit! N INSTALLATION COMPLETE! Now follow the Activation Guide to create an account and begin using Ascent. QSG-16T1-EN Rev. G (3/2021) 3 of 4 Q U I C K S TA R T G U I D E N/O Connected as shown in Step 3 Optional wire splices Connected as shown in Step 3 N/C Close Limit Switch N/O COM N/C Open Limit Switch N/O COM Gate Operator N/C J4 COM J5 J6 N/O RELAY A N/C RELAY B COM J9 GND J8 N/O YOU MUST USE A DRY CONTACT! OPEN Gate Status Check WILL NOT WORK with a decoder! J7 DIGITAL INPUTS EVENT GND STATUS #2 Exceeding 3 V can damage unit! r I M P OR T AN T! N/C N/O GND N/O COM J4 N/O J5 N/C RELAY A COM RELAY B J6 GND J9 #2 GND #1 J8 CLOSE GND OPEN J7 DIGITAL INPUTS EVENT Ascent Connection Terminals #1 Ascent Connection Terminals Wiring for accessories such as a request-to-exit device GND The Status Terminals are designed for low voltage (3 V or less). Check the voltage on your status wires before connecting. If it is above 3 V, you will need to contact Technical Support. B Event Input CLOSE Wiring to enable Gate Status Check CAU T I ON ! GND A Status Check STATUS Model 16-T1 Request-to-Exit (if equipped with limit switches) (58-RTE-P is shown) 4 of 4 Q U I C K S TA R T G U I D E Model 16-T1 IM P OR T ANT ! r Using a Third-Party Power Source (Optional) Connect wires to unit as shown in If you would like to use a third-party power source, such as solar, verify that it conforms to the following specs: Input Current Draw 12–24 VAC/DC no more than 10% beyond this range less than 260 mA @ 12 VDC less than 160 mA @ 24 VDC 3a Step 3. Connect wires to your power source, 3b making sure you connect positive to C A U TIO N ! Double check that you’ve wired from positive on Ascent to positive on your power source and negative on Ascent to negative on your power source. Reverse polarity can damage unit! positive and negative to negative. r IM P O RTA N T! We recommend mounting Ascent inside the gate operator or other weatherproof enclosure when possible. If mounting inside a metal enclosure, the 4G LTE Antenna Extension Kit (p/n 16-ANTX-1) should be purchased and installed. Failure to do so may result in no signal! ? NEED HELP © 2021 Security Brands, Inc. All rights reserved. Call (972) 474-6422 Email [email protected] We are available Mon–Fri / 8am–5pm Central QSG-16T1-EN Rev. G (3/2021) ">

Public link updated
The public link to your chat has been updated.
Advertisement