1 of 6
Q U I C K S TA R T G U I D E
1
Model 16-M4
Unpack box and make sure you have all items shown here.
(Screwdriver not shown.)
STO P
This is a cellular accessory for a gate or door.
An uninterrupted cellular connection
CANNOT BE GUARANTEED!
An emergency egress or primary entry
mechanism SHOULD ALWAYS BE USED!
(transmitter, fire box, mechanical release)
Consult with your dealer, distributor, and/or
system designer for more information.
12-V AC/DC Adapter
(PS-12DC2)
Key
2
Ascent Unit
WARN I N G
Carriage Bolt
( 4x )
r
Unlock and open front door of unit for
mounting, wiring, and setup.
Hex Nut
( 4x )
IM P O R TA N T
r
AUTOMATIC GATES CAN CAUSE SERIOUS
INJURY OR DEATH!
This Ascent unit WILL NOT WORK until the
activation process is COMPLETE!
ALWAYS CHECK THAT THE GATE PATH IS
CLEAR BEFORE OPERATING!
Follow the included Activation Guide to get
this unit activated.
REVERSING OR OTHER SAFETY DEVICES
SHOULD ALWAYS BE USED!
If you need help or have any questions, please
contact Summit Control at (972) 474-6422.
Continued on next page...
2 of 6
Q U I C K S TA R T G U I D E
Mount unit to pedestal using included
mounting hardware.
(This step may be completed later.)
3
Model 16-M4
What’s what?
All important components labeled
Ascent Camera
For automatic and on-demand
photo capture
SIM Card
r
IMPO R T A NT
r
We recommend mounting the unit on a
gooseneck pedestal using the included
mounting hardware.
If using alternate mounting, the
4G LTE Antenna Extension Kit
(Model 16-ANTX-1)
should be purchased and installed.
Failure to do so may result in NO SIGNAL!
C AUT I O N
Use all four carriage bolts when mounting
the unit to a pedestal.
Leave the “hockey puck” antenna in place
even if using an antenna extension.
Wiegand Device Terminals
For wiring to Wiegand devices
See Page 6
Antenna Jacks
Antenna extension kits
connect here
Status and Event Terminals
For enabling gate status and
connecting request-to-exit devices
See Pages 4 and 5
Relay Status LEDs
Relay is active when lit
Power and Relay Terminals
For wiring to power and
gate operator or door opener
See Page 3
Seal all openings created in the enclosure.
Failure to follow these instructions can
damage the unit!
© 2020 Security Brands, Inc. All rights reserved.
Inside of front door shown.
Wiring/cabling not shown for clarity.
QSG-16M4-EN
Rev. B (12/2020)
3 of 6
Q U I C K S TA R T G U I D E
Connect wires
Feed wires through back of unit,
and connect as shown using
included screwdriver.
Ascent Power and Relay Terminals
Do not exceed 24 VAC/DC! Failure to choose a
compatible power source can damage the unit!
Gate Operator / Door Opener
DIGITAL INPUTS
CLOSE
STOP
OPEN
COM
REVERSE LOOP
COM
FREE EXIT
COM
RADIO
COM
POWER (+)
GND
J12
#3
GND
J9
#2
GND
J8
N/C
COM
N/O
J5
N/C
J4
COM
J3
N/O
RELAY B
NEG. (–)
RELAY A
POS. (+)
POWER
#1
12–24 VAC/DC
If the included 12-V AC/DC adapter will not be
used, please go to Page 5 and follow the
procedure, Using a Third-Party Power Source.
If installing a postal lock, go to
securitybrandsinc.com/resources/
Excessive force can damage unit!
CA U TI O N
Additional wiring diagrams can
be found on Pages 4–6.
POWER (–)
4
Model 16-M4
Relay B can be wired to a second device in the same manner.
Consult gate/door opener
manual for exact connections.
+ –
Terminals vary widely across
manufacturers and models.
OR
Third-Party 12–24-VAC/DC
Power Source
The GROUND terminal is optional
unless required by local code(s).
If using, please connect to earth
ground or equivalent.
12-V AC/DC Adapter
(Model PS-12DC2 included)
If plugging into duplex outlet,
remove screw from outlet plate,
and secure with included screw.
4 of 6
Q U I C K S TA R T G U I D E
Ascent Status and Event Terminals
Make sure the gate path is clear before
completing Step 5!
0
1
2
Adding and deleting codes is done through
Summit Control and NOT from keypad on unit!
EVENT
J7
J13
J6
CA U TI O N
The Status Terminals are designed
for low voltage (3 V or less). Check
the voltage on your status wires
before connecting. If it is above 3 V,
please contact Technical Support.
Exceeding 3 V can damage the unit!
r I MP O RTA NT r
Optional
wire
splices
GND
N/O
Gate Status Check WILL NOT WORK
with a decoder!
Key in temporary code 2012 on
keypad and confirm gate opens. If it
does, close and lock front door of unit.
2
GATE 2
OPEN
5
GATE 1
CLOSE
For connecting accessories not mentioned,
please contact Technical Support.
Wiring to enable Gate Status Check
GND
Wiring diagrams for connecting to accessory
devices can be found on Pages 4–6.
A Status Check
OPEN
Before going forward, double check all
wiring and make sure the unit has power!
CLOSE
GND
S T OP
Model 16-M4
N/C
YOU MUST USE A DRY CONTACT!
Close Limit Switch
N/O
COM
N
N/C
INS T A L L A T I O N C O M P L E T E !
Now follow the Activation Guide to create an
account and begin using Ascent.
© 2020 Security Brands, Inc. All rights reserved.
Open Limit Switch
N/O
COM
Gate Operator
(if equipped with limit switches)
QSG-16M4-EN
Rev. B (12/2020)
5 of 6
Q U I C K S TA R T G U I D E
Model 16-M4
Using a Third-Party
Power Source (Optional)
B Event Input
Wiring for accessories such as a request-to-exit device
Ascent Status and Event Terminals
GATE 1
GATE 2
EVENT
I MP O RTA NT
r
r
Verify your power source is compatible with
the unit’s electrical specifications below.
Not intended for solar applications!
J7
J13
J6
Input
12–24 VAC/DC
no more than 10% beyond this range
less than 690 mA @ 12 VDC
less than 420 mA @ 24 VDC
GND
N/O
CLOSE
GND
OPEN
CLOSE
GND
OPEN
Current Draw
4a
Connect wires to unit as shown in
Step 4.
4b
Connect wires to your power source,
making sure you connect positive to
positive and negative to negative.
Request-to-Exit Device
(58-RTE-P is shown)
CA U TI O N
Double check that you have wired from
positive on the Ascent unit to positive on your
power source and negative on the Ascent unit
to negative on your power source.
Reverse polarity can damage the unit!
6 of 6
Q U I C K S TA R T G U I D E
Model 16-M4
C Wiegand Device
Wiring for a Wiegand device such as a card reader
Ascent Wiegand Device Terminals
DOOR/READER A
+12V
LED 2
J18
DATA 0
GND
J19
DATA 0
DATA 1
GND
J16
+12V
LED 1
LED 2
LED 1
LED 2
DATA 1
DATA 0
GND
J15
WIEGAND 2
LED 1
WIEGAND 1
WIEGAND OUTPUTS
+12V
DOOR/READER B
DATA 1
Wiegand Device
CA U TI O N
Disconnect power to the Ascent unit
before connecting Wiegand devices.
Failure to disconnect power can
damage the unit!
Call (972) 474-6422
Email [email protected]
We are available Mon–Fri / 8am–5pm Central
© 2020 Security Brands, Inc. All rights reserved.
QSG-16M4-EN