Airwell GC 30 DCI Service manual
Airwell GC 30 DCI is a powerful and efficient R410A outdoor unit designed for use with SX DCI indoor units. With its high COP and low noise levels, it's an excellent choice for residential and commercial applications. The GC 30 DCI is easy to install and service, and it comes with a variety of features that make it a great value for the price. Whether you're looking to cool or heat your home or business, the Airwell GC 30 DCI is a great option.
PDF
Download
Document
Advertisement
Advertisement
SX DCI Series Indoor Units Outdoor Units SX 9 DCI GC 9 DCI SX 12 DCI GC 12 DCI SX 18 DCI GC 18 DCI SX 24 DCI GC 24 DCI SX 30 DCI GC 30 DCI REFRIGERANT R410A SM SX DCI 1-A.3 GB HEAT PUMP AUGUST – 2008 CONTENT LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE PAGES Note: Changes in the pages are indicated by a “Revision#” in the footer of each effected page (when none indicates no changes in the relevant page). All pages in the following list represent effected/ non effected pages divided by chapters. Dates of issue for original and changed pages are: Original ....... 0 ........ April 2006 Total number of pages in this publication is 88 consisting of the following: Page No. Revision No. # Page No. Revision No. # Page No. Revision No. # Title .......................3 A ...........................3 i .............................3 1-1 - 1-3 ................3 2-1 - 2-5 ................3 3-1 ........................3 4-1 - 4-2 ................3 5-1 - 5-24 ..............3 6-1 - 6-5 ................3 7-1 ........................3 8-1 - 8-3 ................3 9-1 ........................3 10-1 ......................3 11-1-11-7...............3 12-1-12-20 ............3 13-1-13-11 ............3 14-1 ......................3 • Zero in this column indicates an original page. *Due to constant improvements please note that the data on this service manual can be modified with out notice. **Photos are not contractual A CONTENT SM SX DCI 1-A.3 GB TABLE OF CONTENTS Table of Contents 1. INTRODUCTION ...................................................................................................1-1 2. PRODUCT DATA SHEET ......................................................................................2-1 3. RATING CONDITIONS ..........................................................................................3-1 4. OUTLINE DIMENSIONS........................................................................................4-1 5. PERFORMANCE DATA & PRESSURE CURVES ................................................5-1 6. SOUND LEVEL CHARACTERISTICS ...................................................................6-1 7. ELECTRICAL DATA ...............................................................................................7-1 8. WIRING DIAGRAMS .............................................................................................8-1 9. REFRIGERATION DIAGRAMS .............................................................................9-1 10. TUBING CONNECTIONS ......................................................................................10-1 11. CONTROL SYSTEM ..............................................................................................11-1 12. TROUBLESHOOTING ...........................................................................................12-1 13. EXPLODED VIEWS AND SPARE PARTS LISTS ..................................................13-1 14. APPENDIX A..........................................................................................................14-1 SM SX DCI 1-A.3 GB i INTRODUCTION 1. INTRODUCTION 1.1 General The SX split ceiling mounted range comprise RC (heat pump) models, as follows: ● Heat Pump 1.2 SX 9, SX 12, SX 18, SX 24, SX 30. Main Features The SX series benefits from the most advanced technological innovations, namely: ● DC Inverter Technology R410A models. ● High COP. ● Low indoor and outdoor noise levels. ● Microprocessor control. ● Infrared remote control with LED. ● Easy access to the interconnecting tubing and wiring connections, main control panel can slide out for service . ● Automatic treated air sweep (by definition in NPR). ● Fresh Air & Distribution treated air to adjacent room. ● Indoor centrifugal fan. ● Easy installation and service. 1.3 Indoor Unit The indoor unit is a floor/ ceiling mounted, and can be easily fitted to many types of residential and commercials applications. It includes: ● Coil with hydrophilic aluminum fins. ● Motorized flaps (two step motors) ● Advanced electronic control box assembly (DCI storm) ● Mounting plate 1.4 Filtration The SX series presents several types assembly (DCI storm). ● Easily accessible, and re-usable pre-filters (mesh). SM SX DCI 1-A.3 GB CONTENT 1-1 INTRODUCTION 1.5 Control The microprocessor indoor controller, and an infrared remote control, supplied as standard, providing complete operating function and programming. For further details please refer to the Operation Manual, Appendix A. 1.6 Outdoor Unit The SX outdoor units can be installed as floor or wall mounted units by using a wall supporting bracket. The metal sheets are protected by anti- corrosion paint work allowing long life resistance. All outdoor units are pre-charged. For further information please refer to the Product Data Sheet, Chapter 2. It includes : ● Compressor mounted in a soundproofed compartment : Single Rotary – for SX 9 DCI and SX 12 DCI. Scroll – for SX 18 DCI. Twin Rotary – for SX 24 DCI and SX 30 DCI. ● Axial fan. ● Outdoor coil with hydrophilic louver fins for RC units. ● Outlet air fan grill. ● Service valves” flare” type connection. ● Interconnecting wiring terminal block. 1.7 Tubing Connections Flare type interconnecting tubing to be produced on site. For further details please refer to the Installation Manual, Chapter 10tttvv. 1.8 Accessories RCW Wall Mounted Remove Control The RCW remote control is mounted on the wall, and controls the unit either as an infrared remote control or as a wired controller.The wired controller can control up to 10 indoor units with the same program settings and adjustment. For further details please refer to the Technical Service Manual 1.9 Inbox Documentation Each unit is supplied with its own installation and operation manuals. 1-2 CONTENT SM SX DCI 1-A.3 GB INTRODUCTION 1.10 Matching Table 1.10.1 R410A INDOOR UNITS OUTDOOR UNITS MODEL REFRIGER. SX 9 SX 12 SX 18 GC 9-12-18 R410A √ √ √ GC 24-30 R410A SX 24 SX 30 √ √ The above table lists outdoor units and SX DCI indoor units which can be matched together. In addition the listed outdoor units can be matched with other types of indoor units such as cassettes and wall mounted. For further information please refer to the relevant Service Manual. SM SX DCI 1-A.3 GB CONTENT 1-3 PRODUCT DATA SHEET 2. PRODUCT DATA SHEET 2.1 SX 9 DCI R410A Model Indoor Unit SX 9 DCI Model Outdoor Unit GC 9 DCI Installation Method of Pipe Characteristics Units Btu/hr kW kW W/W Capacity (1) OUTDOOR INDOOR Power input (1) EER (Cooling) or COP(Heating) (1) Energy efficiency class Power supply Rated current Starting current Circuit breaker rating Fan type & quantity Fan speeds Air flow (2) External static pressure Sound power level (3) Sound pressure level (4) Moisture removal Condenstate drain tube I.D Dimensions Weight Package dimensions Package weight Units per pallet Units stacking Refrigerant control Compressor type,model Fan type & quantity Fan speeds Air flow Sound power level Sound pressure level (4) Dimensions Weight Package dimensions Packaged weight Units per pallet Stacking height Refrigerant type Refrigerant chargless distance Additional charge per 1 meter Connections between units Operation control type Heating elements (Option) Others (1) (2) (3) (4) V/Ph/Hz A A A H/M/L H/M/L Min-Max H/M/L H/M/L RPM m3/hr Pa dB(A) dB(A) l/hr Mm Mm Kg Mm Kg Units Units WxDxH WxDxH H/L H/L H/L H/L WxDxH RPM m3/hr dB(A) dB(A) Mm Kg Mm Kg Units Units WxDxH Liquid line Suction line Max.tubing length Max.height difference kg/m g/m In.(mm) In.(mm) m. m. Flared Cooling Heating 8530(4780~12280) 10920(5120~15350) 2.5(1.4-3.6) 3.2(1.5~4.5) 0.62(0.42-1.1) 0.93(0.4~1.6) 4.03 3.41 A B 220-240V/Single/50Hz 2.7 4.1 10.5 35 Centrifugal x 2 760/670/500 400/350/300 0 50/49/47 39/37/35 1 16 820*190*630 21 890*280*710 25 14units per pallet 7 levels EEV Single Rotary,DC Inverter,Panasonic 5RS102XAB Propeller(direct) x 1 830 1780 61 51 795*290*610 38 945*395*655 42 9 3 levels R410A 1.10kg/7.5m No Need 1/4"(6.35) 3/8"(9.53) Max.20 Max.10 Remote control kW Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511. Airflow in ducted units; at nominal external static pressure. Sound power in ducted units is measured at air discharge. Sound pressure level measured at 1 meter distance from unit. SM SX DCI 1-A.3 GB CONTENT 2-1 PRODUCT DATA SHEET 2.2 SX 12 DCI R410A Model Indoor Unit SX 12 DCI Model Outdoor Unit GC 12 DCI Installation Method of Pipe Characteristics Flared Capacity (1) Power input (1) EER (Cooling) or COP(Heating) (1) Energy efficiency class Units Cooling Heating Btu/hr 11940(5120~15010) 14330(5120~17060) kW 3.5(1.5-4.4) 4.2(1.5~5.0) kW 0.98(0.46-1.3) 1.31(0.35~1.58) W/W 3.57 3.21 A Power supply V/Ph/Hz Rated current A Starting current A Circuit breaker rating A INDOOR Fan type & quantity C 220-240V/Single/50Hz 4.3 5.7 10.5 35 Centrifugal x 2 Fan speeds H/M/L RPM 830/760/500 Air flow (2) External static pressure H/M/L m3/hr 450/400/300 Min-Max Pa 0 Sound power level (3) H/M/L dB(A) 56/53/51 Sound pressure level (4) Moisture removal H/M/L dB(A) 45/41/38 l/hr 1.5 Condenstate drain tube I.D Dimensions Mm 16 WxDxH Mm 820*190*630 Kg 22 WxDxH Mm 890*280*710 Weight Package dimensions Package weight kg 26 Units per pallet units 14units per pallet Units stacking units 7 levels Refrigerant control EEV Compressor type,model Single Rotary,DC Inverter,Panasonic 5RS102XAB OUTDOOR Fan type & quantity Propeller(direct) x 1 Fan speeds H/L RPM 830 Air flow H/L m3/hr 1780 Sound power level H/L dB(A) 62 Sound pressure level (4) Dimensions H/L dB(A) 52 WxDxH mm 795*290*610 Weight Package dimensions WxDxH Packaged weight kg 38.5 mm 945*395*655 kg 42.5 Units per pallet Units 9 Stacking height units 3 levels kg/m 1.20kg/7.5m Refrigerant type R410A Refrigerant chargless distance Additional charge per 1 meter Connections between units g/m No Need Liquid line In.(mm) 1/4"(6.35) Suction line In.(mm) 3/8"(9.53) m. Max.20 Max.tubing length Max.height difference m. Operation control type Heating elements (Option) Others (1) (2) (3) (4) Max.10 Remote control kW Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511. Airflow in ducted units; at nominal external static pressure. Sound power in ducted units is measured at air discharge. Sound pressure level measured at 1 meter distance from unit. 2-2 CONTENT SM SX DCI 1-A.3 GB PRODUCT DATA SHEET 2.3 SX 18 DCI R410A Model Indoor Unit SX 18 DCI Model Outdoor Unit GC 18 DCI Installation Method of Pipe Characteristics Flared Capacity (1) Power input (1) EER (Cooling) or COP(Heating) (1) Energy efficiency class Units Cooling Heating Btu/hr 17000(5120-20460) 20460(5120-24550) kW 5.0(1.5-6.0) 5.8(1.5~7.2) kW 1.65(0.5-2.1) 1.69(0.45-2.1) W/W 3.03 3.43 B B Power supply V/Ph/Hz Rated current A Starting current A Circuit breaker rating A 220-240V/Single/50Hz 7.2 35 INDOOR Fan type & quantity Centrifugal x 2 Fan speeds H/M/L RPM 1050/950/700 Air flow (2) External static pressure H/M/L m3/hr 870/750/600 Min-Max Pa 0 Sound power level (3) H/M/L dB(A) 65/60/56 Sound pressure level (4) Moisture removal H/M/L dB(A) 51/48/45 Condenstate drain tube I.D Dimensions WxDxH Weight Package dimensions WxDxH l/hr 2 mm 16 mm 1200*190*630 kg 30 mm 1270*280*710 Package weight kg 35 Units per pallet units 7units per pallet Units stacking units 7 levels Refrigerant control EEV Compressor type,model Scroll compressor 5CS130XCC03 Fan type & quantity Propeller(direct) x 1 Fan speeds H/L RPM 920 Air flow H/L m3/hr 2160 Sound power level Sound pressure level Dimensions OUTDOOR 7.7 10.5 H/L dB(A) 63 H/L dB(A) 53 WxDxH mm 795*290*610 (4) Weight Package dimensions WxDxH Packaged weight kg 39 mm 945*395*655 kg 43 Units per pallet Units 9 Stacking height units 3 levels kg/m 1.50kg/7.5m Refrigerant type R410A Refrigerant chargless distance Additional charge per 1 meter Connections between units g/m No Need Liquid line In.(mm) 1/4"(6.35) Suction line In.(mm) 1/2"(12.7) Max.tubing length m. Max.30 Max.height difference m. Max.10 Operation control type Heating elements (Option) Remote control kW Others (1) (2) (3) (4) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511. Airflow in ducted units; at nominal external static pressure. Sound power in ducted units is measured at air discharge. Sound pressure level measured at 1 meter distance from unit. SM SX DCI 1-A.3 GB CONTENT 2-3 PRODUCT DATA SHEET 2.4 SX 24 DCI R410A Model Indoor Unit SX 24 DCI Model Outdoor Unit GC 24 DCI Installation Method of Pipe Characteristics H/M/L H/M/L Min-Max H/M/L RPM m3/hr Pa dB(A) Flared Cooling Heating 23200(5120~25590) 25910(5110-30000) 6.80(1.50-7.60) 7.60(1.60~8.60) 2.25(0.50-2.68) 2.05(05~2.30) 3.02 3.61 B A 220-240V/Single/50Hz 10.1 9.6 15 45 Centrifugal x 2 1300/1200/1050 1020/930/760 0 67/64/60 H/M/L dB(A) 56/53/49 l/hr mm 2.5 16 mm kg mm kg units units 1200x630x190 32 1270x710x280 36 7 7 Units Btu/hr kW kW W/W Capacity (1) Power input (1) EER (Cooling) or COP(Heating) Energy efficiency class Power supply Rated current Starting current Circuit breaker rating Fan type & quantity Fan speeds (1) Air flow (2) External static pressure INDOOR Sound power level (3) Sound pressure level (4) Moisture removal Condenstate drain tube I.D OUTDOOR Dimensions Weight Package dimensions Packaged weight Units per pallet Stacking height WxHxD WxHxD Refrigerant control Compressor type,model Fan type & quantity Fan speeds Air flow Sound power level H/L H/L H/L RPM m3/hr dB(A) EEV Two Rotary,Mitsubishi TNB220F Propeller(direct) x 1 850 3600 66 Sound pressure level (4) H/L dB(A) 56 WxHxD mm kg mm kg Units units 950*340*835 65.5 1087x477x910 70 2 2 levels R410A 2.4/7.5 No Need 3/8”(9.53) 5/8”(15.88) Max.30 Max.15 Remote control Dimensions Weight Package dimensions Packaged weight Units per pallet Stacking height Refrigerant type Refrigerant chargless distance Additional charge per 1 meter Connections between units Operation control type Heating elements (Option) Others (1) (2) (3) (4) V/Ph/Hz A A A WxHxD Liquid line Suction line Max.tubing length Max.height difference kg/m g/m In.(mm) In.(mm) m. m. kW Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511. Airflow in ducted units; at nominal external static pressure. Sound power in ducted units is measured at air discharge. Sound pressure level measured at 1 meter distance from unit. 2-4 CONTENT SM SX DCI 1-A.3 GB PRODUCT DATA SHEET 2.5 SX 30 DCI R410A Model Indoor Unit SX 30 DCI Model Outdoor Unit GC 30 DCI Installation Method of Pipe Characteristics Flared Units Cooling Heating Btu/hr 25570(6820-32390) 30000(5110-35800) kW 7.5(1.6-8.6) 8.4(1.8-9.8) Capacity (1) (1) OUTDOOR INDOOR Power input EER (Cooling) or COP(Heating) (1) Energy efficiency class Power supply Rated current Starting current Circuit breaker rating Fan type & quantity Fan speeds H/M/L H/M/L Air flow (2) External static pressure Min-Max H/M/L Sound power level (3) H/M/L Sound pressure level (4) Moisture removal Condenstate drain tube I.D Dimensions WxHxD Weight Package dimensions WxHxD Packaged weight Units per pallet Stacking height Refrigerant control Compressor type,model Fan type & quantity Fan speeds H/L Air flow H/L Sound power level H/L H/L Sound pressure level (4) Dimensions WxHxD Weight Package dimensions WxHxD Packaged weight Units per pallet Stacking height Refrigerant type Refrigerant chargless distance Additional charge per 1 meter Liquid line Suction line Connections between units Max.tubing length Max.height difference Operation control type Heating elements (Option) kW W/W V/Ph/Hz A A A RPM m3/hr Pa dB(A) dB(A) l/hr mm mm kg mm kg units units RPM m3/hr dB(A) dB(A) mm kg mm kg Units units kg/m g/m In.(mm) In.(mm) m. m. 2.49(0.5-3.1) 2.46(0.5-2.8) 3.01 3.41 B B 220-240V/Single/50Hz 11.3 11.0 15 45 Centrifugal x 2 1300/1200/1050 1020/930/760 0 67/64/60 56/53/49 2.9 16 1200x630x190 32 1270x710x280 36 7 7 EEV Two Rotary,Mitsubishi TNB220F Propeller(direct) x 1 850 3600 66 56 950*340*835 66 1087x477x910 70 2 2 levels R410A 2.75/7.5 No Need 3/8”(9.53) 5/8”(15.88) Max.30 Max.15 Remote control kW Others (1) (2) (3) (4) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511. Airflow in ducted units; at nominal external static pressure. Sound power in ducted units is measured at air discharge. Sound pressure level measured at 1 meter distance from unit. SM SX DCI 1-A.3 GB CONTENT 2-5 RATING CONDITIONS 3. RATING CONDITIONS Standard conditions in accordance with ISO 5151, ISO 13253 (for ducted units) and EN 14511. Cooling: Indoor: 27oC DB 19oC WB Outdoor: 35 oC DB Heating: Indoor: 20oC DB Outdoor: 7oC DB 6oC WB 3.1 Operating Limits R410A Indoor Cooling Heating Voltage SM SX DCI 1-A.3 GB Outdoor Upper limit 32oC DB 23oC WB 46oC DB Lower limit 21oC DB 15oC WB -10oC DB Upper limit 27oC DB 24oC DB 18oC WB Lower limit 10oC DB -15oC DB -16oC WB 1PH 198 – 264 V 3PH N/A CONTENT 3-1 OUTLINE DIMENSIONS 4. OUTLINE DIMENSIONS 4.1 Indoor Unit: SX 9, 12 DCI 4.2 Indoor Unit: SX 18, 24, 30 DCI SM SX DCI 1-A.3 GB CONTENT 4-1 OUTLINE DIMENSIONS 4.3 Outdoor Unit: GC 9, 12, 18 DCI 4.4 Outdoor Unit: GC 24, 30 DCI 4-2 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5. PERFORMANCE DATA 5,1 SX 9 DCI 5.1.1 Cooling Capacity (kW) – Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB/WB TEMPERATURE [oC] OU COIL ENTERING AIR DB TEMPERATURE [oC] DATA TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI TC SC PI -10 - 20 (protection range) 25 30 35 40 46 22/15 24/17 27/19 29/21 32/23 2.42 2.09 0.49 2.30 2.04 0.54 2.18 1.98 0.60 2.07 1.93 0.66 1.93 1.87 0.73 80 - 110 % of nominal 80 - 105 % of nominal 25 - 50 % of nominal 2.57 2.73 2.89 2.13 2.18 2.22 0.50 0.51 0.52 2.46 2.62 2.77 2.08 2.12 2.17 0.56 0.55 0.57 2.34 2.66 2.50 2.03 2.07 2.11 0.62 0.61 0.63 2.23 2.54 2.38 1.97 2.02 2.06 0.67 0.68 0.69 2.09 2.24 2.40 1.91 1.95 2.00 0.74 0.75 0.75 3.05 2.26 0.52 2.93 2.21 0.58 2.82 2.16 0.64 2.70 2.10 0.70 2.56 2.04 0.76 LEGEND TC SC PI WB DB ID OU 5.1.2 – – – – – – – Total Cooling Capacity, kW Sensible Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Cooling Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ratio 1.10 1.00 0.90 0.80 0.70 0.60 0.50 20 25 30 35 40 45 Outdoor Temperature [ºC] SM SX DCI 1-A.3 GB CONTENT 5-1 PERFORMANCE DATA & PRESSURE CURVES 5.1.3 Heating Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB TEMPERATURE [oC] OU COIL ENTERING AIR DB/WB TEMPERATURE [oC] -15/-16 -10/-12 -7/-8 -1/-2 2/1 7/6 10/9 15/12 15-24 (Protection Range) DATA 15 20 25 TC PI TC PI TC PI TC PI TC 2.04 0.56 2.27 0.67 2.44 0.76 2.53 0.80 2.58 1.75 0.67 1.98 0.79 2.16 0.87 2.24 0.92 2.30 PI 0.83 1.89 0.61 2.12 0.73 2.30 0.82 2.38 0.86 2.44 0.89 TC PI TC PI TC PI TC PI 3.34 0.87 3.53 0.93 3.71 0.98 3.20 0.93 3.06 0.99 3.24 1.04 3.43 1.09 0.94 3.38 0.98 3.57 1.03 85 - 105 % of nominal 80 - 120 % of nominal LEGEND TC PI WB DB ID OU 5.1.4 – – – – – – Total Heating Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Heating Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ration 1.10 1.00 0.90 0.80 0.70 0.60 0.50 -15 -10 -5 0 5 10 15 Outdoor WB Temperature [deg C] 5-2 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.1.5 Model: SX 9 DCI Cooling – Test Mode Suction Pressure Vs.Outdoor Temp. Suction Pressure [kPa] 1400 Indoor DB/WB 1300 1200 1100 22/15 1000 24/17 900 27/19 800 29/21 700 32/23 600 500 10 15 20 25 30 35 40 45 Outdoor DB Temperature[ºC ] Discharge Pressure [kPa] Discharge Pressure Vs. Outdoor Temp. 4000 3750 3500 3250 3000 2750 2500 2250 2000 1750 1500 1250 1000 Indoor DB/WB 22/15 24/17 27/19 29/21 32/23 10 15 20 25 30 35 40 45 Outdoor DB Temperature[ºC ] SM SX DCI 1-A.3 GB CONTENT 5-3 PERFORMANCE DATA & PRESSURE CURVES 5.1.6 Heating – Test Mode Suction Pressure [kPa] Suction Pressure Vs.Outdoor Temp. 1300 1200 1100 1000 900 800 700 600 500 400 300 200 -15 15 20 25 -10 -5 0 5 10 15 Outdoor WB Temperature [ºC] Discharge Pressure [kPa] Discharge Pressure Vs. Outdoor Temp. 4000 3750 3500 3250 3000 2750 2500 2250 2000 1750 1500 1250 1000 -15 Indoor DB 15 20 25 -10 -5 0 5 10 15 Outdoor WB Temperature [ºC] 5-4 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.2 SX 12 DCI 5.2.1 Cooling Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB/WB TEMPERATURE [oC] OU COIL ENTERING AIR DB TEMPERATURE [oC] 22/15 DATA -10 - 20 (protection range) 25 30 35 40 46 24/17 27/19 29/21 32/23 TC SC PI TC SC PI TC SC 3.38 2.65 0.77 3.22 2.58 PI 0.86 80 - 110 % of nominal 80 - 105 % of nominal 25 - 50 % of nominal 3.60 3.83 4.05 2.70 2.75 2.81 0.78 0.80 0.81 3.44 3.66 3.88 2.63 2.69 2.74 0.89 0.88 0.90 TC 3.06 3.28 3.50 3.72 SC 2.51 2.57 2.62 2.67 2.73 PI 0.95 0.97 0.98 0.99 1.01 TC 2.89 3.12 3.56 3.78 SC PI TC SC PI 2.45 1.04 2.70 2.37 1.15 2.50 1.06 2.92 2.42 1.16 3.34 2.55 1.07 3.14 2.47 1.18 2.61 1.08 3.36 2.53 1.19 2.66 1.10 3.58 2.58 1.21 4.27 2.86 0.83 4.11 2.79 0.92 3.94 LEGEND TC SC PI WB DB ID OU 5.2.2 – – – – – – – Total Cooling Capacity, kW Sensible Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factor Cooling Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ratio 1.10 1.00 0.90 0.80 0.70 0.60 0.50 20 25 30 35 40 45 Outdoor Temperature [ºC] SM SX DCI 1-A.3 GB CONTENT 5-5 PERFORMANCE DATA & PRESSURE CURVES 5.2.3 Heating Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB TEMPERATURE [oC] OU COIL ENTERING AIR DB/WB TEMPERATURE [oC] -15/-16 -10/-12 -7/-8 -1/-2 2/1 7/6 10/9 15/12 15-24 (Protection Range) DATA 15 20 25 TC PI TC PI TC PI TC PI TC 2.67 0.79 2.98 0.95 3.20 1.07 3.32 1.13 3.39 2.49 0.87 2.79 1.03 3.02 1.15 3.13 1.21 3.20 1.25 2.30 0.95 2.60 1.11 2.83 1.23 2.94 1.29 3.02 4.20 1.31 4.01 1.39 4.26 1.46 4.50 1.54 PI 1.17 TC PI TC PI TC PI TC PI 4.39 1.23 4.63 1.30 4.87 1.38 1.33 4.44 1.38 4.68 1.46 85 - 105 % of nominal 80 - 120 % of nominal LEGEND TC PI WB DB ID OU 5.2.4 – – – – – – Total Heating Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Heating Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ration 1.10 1.00 0.90 0.80 0.70 0.60 0.50 -15 -10 -5 0 5 10 15 Outdoor WB Temperature [deg C] 5-6 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.2.5 Model: SX 12 DCI Cooling – Test Mode Suction Pressure VS.Outdoor Temp. Suction Pressure [kPa] 1400 Indoor DB/WB 1300 22/15 1200 24/17 1100 27/19 1000 29/21 900 32/23 800 700 600 500 10 15 20 25 30 35 40 45 Outdoor DB Temperature[ºC ] Discharge Pressure [kPa] Discharge Pressure VS. Outdoor Temp. 4000 3750 3500 3250 3000 2750 2500 2250 2000 1750 1500 1250 1000 Indoor DB/WB 22/15 24/17 27/19 29/21 32/23 10 15 20 25 30 35 40 45 Outdoor DB Temperature[ºC ] SM SX DCI 1-A.3 GB CONTENT 5-7 PERFORMANCE DATA & PRESSURE CURVES 5.2.6 Heating – Test Mode Suction Pressure VS.Outdoor Temp. 1300 Suction Pressure [kPa] 1200 1100 1000 900 800 15 700 20 600 25 500 400 300 200 -15 -10 -5 0 5 10 15 Outdoor WB Temperature [ºC] Discharge Pressure [kPa] Discharge Pressure VS. Outdoor Temp. 4000 3750 3500 3250 3000 2750 Indoor DB 15 2500 2250 2000 1750 1500 1250 1000 -15 20 25 -10 -5 0 5 10 15 Outdoor WB Temperature [ºC] 5-8 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES Capacity Correction Factor Due to Tubing Length 5.3.1 SX 9, 12 DCI :Cooling Capacity Ratio 5.3 1.01 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.91 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Tubing Length [m ] 5.3.2 Heating Capacity Ratio 1.02 1.00 0.98 0.96 0.94 0.92 0.90 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Tubing Length [m ] SM SX DCI 1-A.3 GB CONTENT 5-9 PERFORMANCE DATA & PRESSURE CURVES 5.4 SX18 DCI 5.4.1 Cooling Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB/WB TEMPERATURE [oC] OU COIL ENTERING AIR DB TEMPERATURE [oC] 22/15 24/17 29/21 32/23 TC SC PI TC SC PI TC SC PI 4.93 3.35 1.25 4.67 3.22 1.42 80 - 110 % of nominal 80 - 105 % of nominal 25 - 50 % of nominal 5.22 5.51 5.80 3.40 3.45 3.50 1.28 1.30 1.33 4.96 5.25 5.54 3.27 3.32 3.37 1.48 1.45 1.50 6.09 3.55 1.36 5.83 3.42 1.53 TC 4.42 4.71 5.00 5.29 5.58 SC 3.09 3.14 3.24 3.29 PI 1.59 1.62 3.19 1.65 1.68 1.71 TC SC PI TC SC PI 4.17 2.96 1.77 3.86 2.80 1.98 4.46 3.01 1.80 4.15 2.85 2.00 4.75 3.06 1.82 4.44 2.90 2.03 5.04 3.11 1.85 4.73 2.95 2.06 5.33 3.16 1.88 5.02 3.00 2.09 DATA -10 - 20 (protection range) 25 30 35 40 46 27/19 LEGEND TC SC PI WB DB ID OU 5.4.2 – – – – – – – Total Cooling Capacity, kW Sensible Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Cooling Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ratio 1.10 1.00 0.90 0.80 0.70 0.60 0.50 20 25 30 35 40 45 Outdoor Temperature [ºC] 5-10 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.4.3 Heating Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB TEMPERATURE [oC] OU COIL ENTERING AIR DB/WB TEMPERATURE [oC] -15/-16 -10/-12 -7/-8 -1/-2 2/1 7/6 10/9 15/12 15-24 (Protection Range) DATA 15 20 25 TC PI TC PI TC PI TC PI TC 2.64 1.18 3.48 1.34 4.12 1.45 4.43 1.51 4.65 1.88 1.35 2.72 1.50 3.36 1.62 3.67 1.68 3.89 PI 1.55 2.26 1.27 3.10 1.42 3.74 1.54 4.05 1.59 4.27 1.63 TC PI TC PI TC PI TC PI 6.18 1.61 6.50 1.64 6.82 1.67 5.80 1.69 5.42 1.77 5.74 1.81 6.06 1.84 1.72 6.12 1.72 6.44 1.75 85 - 105 % of nominal 80 - 120 % of nominal LEGEND TC PI WB DB ID OU 5.4.4 – – – – – – Total Heating Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Heating Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ration 1.10 1.00 0.90 0.80 0.70 0.60 0.50 -15 -10 -5 0 5 10 15 Outdoor WB Temperature [deg C] SM SX DCI 1-A.3 GB CONTENT 5-11 PERFORMANCE DATA & PRESSURE CURVES 5.4.5 Model: SX 18 DCI Cooling – Test Mode Suction Pressure VS.Outdoor Temp. Suction Pressure [kPa] 1400 Indoor DB/WB 1300 1200 1100 22/15 1000 24/17 27/19 900 29/21 800 32/23 700 600 500 10 15 20 25 30 35 40 45 Outdoor DB Temperature[ºC ] Discharge Pressure [kPa] Discharge Pressure VS. Outdoor Temp. 4250 4000 3750 3500 3250 3000 2750 2500 2250 2000 1750 1500 1250 1000 Indoor DB/WB 22/15 24/17 27/19 29/21 32/23 10 15 20 25 30 35 40 45 Outdoor DB Temperature[ºC ] 5-12 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.4.6 Heating – Test Mode Suction Pressure VS.Outdoor Temp. Suction Pressure [kPa] 1100 1000 900 15 800 20 700 25 600 500 400 300 200 -15 -10 -5 0 5 10 15 Outdoor WB Temperature [ºC] Discharge Pressure [kPa] Discharge Pressure VS. Outdoor Temp. 4000 3750 3500 3250 3000 2750 2500 2250 2000 1750 1500 1250 1000 -15 Indoor DB 15 20 25 -10 -5 0 5 10 15 Outdoor WB Temperature [ºC] SM SX DCI 1-A.3 GB CONTENT 5-13 PERFORMANCE DATA & PRESSURE CURVES 5.5 Capacity Correction Factor Due to Tubing Length 5.5.1 SX 18 DCI :Cooling 1.01 Capacity ratio 0.99 0.97 0.95 0.93 0.91 0.89 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Tubing length(m ) Heating Capacity ratio 5.5.2 1.02 1.00 0.98 0.96 0.94 0.92 0.90 0.88 0.86 0.84 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Tubing Length(m ) 5-14 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.6 SX 24 DCI 5.6.1 Cooling Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB/WB TEMPERATURE [oC] OU COIL ENTERING AIR DB TEMPERATURE [oC] 22/15 24/17 29/21 32/23 TC SC PI TC SC PI TC SC PI 6.70 5.36 1.70 6.35 5.15 1.94 80 - 110 % of nominal 80 - 105 % of nominal 25 - 50 % of nominal 7.09 7.49 7.88 5.44 5.52 5.60 1.74 1.78 1.82 6.75 7.14 7.54 5.23 5.31 5.39 2.01 1.98 2.05 8.28 5.68 1.85 7.93 5.47 2.09 TC 6.01 6.41 6.80 7.19 7.59 SC 4.94 5.02 5.18 5.26 PI 2.17 2.21 5.10 2.25 2.29 2.33 TC SC PI TC SC PI 5.67 4.73 2.41 5.26 4.48 2.69 6.06 4.81 2.45 5.65 4.56 2.73 6.46 4.89 2.49 6.04 4.64 2.77 6.85 4.97 2.52 6.44 4.72 2.81 7.25 5.05 2.56 6.83 4.80 2.85 DATA -10 - 20 (protection range) 25 30 35 40 46 27/19 LEGEND TC SC PI WB DB ID OU 5.6.2 – – – – – – – Total Cooling Capacity, kW Sensible Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Cooling Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ratio 1.10 1.00 0.90 0.80 0.70 0.60 0.50 20 25 30 35 40 45 Outdoor Temperature [ºC] SM SX DCI 1-A.3 GB CONTENT 5-15 PERFORMANCE DATA & PRESSURE CURVES 5.6.3 Heating Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB TEMPERATURE [oC] OU COIL ENTERING AIR DB/WB TEMPERATURE [oC] -15/-16 -10/-12 -7/-8 -1/-2 2/1 7/6 10/9 15/12 15-24 (Protection Range) DATA 15 20 25 TC PI TC PI TC PI TC PI TC 3.46 1.48 4.57 1.67 5.40 1.81 5.81 1.88 6.09 2.46 1.69 3.57 1.88 4.40 2.02 4.81 2.10 5.09 PI 1.93 2.96 1.58 4.07 1.77 4.90 1.92 5.31 1.99 5.59 2.04 TC PI TC PI TC PI TC PI 8.10 2.00 8.52 2.04 8.94 2.08 7.60 2.11 7.10 2.22 7.52 2.25 7.94 2.29 2.14 8.02 2.15 8.44 2.19 85 - 105 % of nominal 80 - 120 % of nominal LEGEND TC PI WB DB ID OU 5.6.4 – – – – – – Total Heating Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Heating Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ration 1.10 1.00 0.90 0.80 0.70 0.60 0.50 -15 -10 -5 0 5 10 15 Outdoor WB Temperature [deg C] 5-16 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.6.5 Model: SX 24 DCI Cooling – Test Mode Suction Pressure [kPa] Suction Pressure Vs. Outdoor Temp. 1000 960 920 880 840 800 760 720 680 640 600 Indoor DB/WB 22/15 24/17 27/19 29/21 32/23 10 15 20 25 30 35 40 45 O Outdoor DB Temperature[ C] Discharge Pressure [kPa] Discharge Pressure Vs. Temp. 3900 3700 3500 3300 3100 2900 2700 2500 2300 2100 1900 1700 1500 Indoor DB/WB 22/15 24/17 27/19 29/21 32/23 10 15 20 25 30 35 40 45 O Outdoor DB Temperature[ C] SM SX DCI 1-A.3 GB CONTENT 5-17 PERFORMANCE DATA & PRESSURE CURVES 5.6.6 Heating – Test Mode Suction Pressure Vs. Outdoor Temp. Suction Pressure [kPa] 1050 950 850 Indoor DB 750 15 650 550 20 450 25 350 250 -15 -10 -5 0 5 10 15 O Outdoor WB Temperature[ C] Discharge Pressure [kPa] Discharge Pressure Vs. Outdoor Temp. 3700 3500 3300 3100 2900 2700 2500 2300 2100 1900 1700 Indoor DB 15 20 25 -15 5-18 -10 -5 0 5 O Outdoor WB Temperature[ C] CONTENT 10 15 SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.7 Capacity Correction Factor Due to Tubing Length 5.7.1 SX 24 DCI :Cooling 1.01 0.99 Capacity Ratio 0.97 0.95 0.93 0.91 0.89 0.87 0.85 5 Heating Tube Length(m) 5.7.2 6 7 7.5 10 15 20 25 30 Tube Length [m]) 5 6 7 7.5 10 15 20 20 25 25 Heating 1.05 Capacity Ratio 1.00 0.95 0.90 0.85 0.80 0.75 0.70 5 SM SX DCI 1-A.3 GB 6 7 7.5 10 15 Tube Length [m] CONTENT 30 5-19 PERFORMANCE DATA & PRESSURE CURVES 5.8 SX 30 DCI 5.8.1 Cooling Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB/WB TEMPERATURE [oC] OU COIL ENTERING AIR DB TEMPERATURE [oC] 22/15 24/17 29/21 32/23 TC SC PI TC SC PI TC SC PI 7.39 5.72 1.88 7.01 5.49 2.14 80 - 110 % of nominal 80 - 105 % of nominal 25 - 50 % of nominal 7.82 8.26 8.69 5.80 5.88 5.97 1.92 1.97 2.01 7.44 7.88 8.31 5.58 5.66 5.75 2.23 2.19 2.27 9.13 6.05 2.05 8.75 5.83 2.31 TC 6.63 7.07 7.50 7.94 8.37 SC 5.27 5.35 5.52 5.61 PI 2.41 2.45 5.44 2.49 2.53 2.57 TC SC PI TC SC PI 6.25 5.05 2.67 5.80 4.78 2.98 6.69 5.13 2.71 6.23 4.86 3.02 7.12 5.22 2.75 6.67 4.95 3.07 7.56 5.30 2.79 7.10 5.03 3.11 7.99 5.39 2.84 7.54 5.12 3.15 DATA -10 - 20 (protection range) 25 30 35 40 46 27/19 LEGEND TC SC PI WB DB ID OU 5.8.2 – – – – – – – Total Cooling Capacity, kW Sensible Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Cooling Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ratio 1.10 1.00 0.90 0.80 0.70 0.60 0.50 20 25 30 35 40 45 Outdoor Temperature [ºC] 5-20 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.8.3 Heating Capacity (kW) - Run Mode 230[V] : Indoor Fan at High Speed. ID COIL ENTERING AIR DB TEMPERATURE [oC] OU COIL ENTERING AIR DB/WB TEMPERATURE [oC] DATA 15 20 25 TC PI TC PI TC PI TC PI TC 3.96 1.78 5.23 2.02 6.18 2.19 6.65 2.28 6.97 2.82 2.04 4.09 2.27 5.04 2.44 5.51 2.53 5.83 PI 2.34 3.39 1.91 4.66 2.14 5.61 2.32 6.08 2.40 6.40 2.46 TC PI TC PI TC PI TC PI 9.27 8.70 2.55 2.42 9.75 9.18 2.47 2.60 10.23 9.66 2.52 2.64 85 - 105 % of nominal 80 - 120 % of nominal 8.13 2.68 8.61 2.72 9.09 2.77 -15/-16 -10/-12 -7/-8 -1/-2 2/1 7/6 10/9 15/12 15-24 (Protection Range) 2.59 LEGEND TC PI WB DB ID OU 5.8.4 – – – – – – Total Heating Capacity, kW Power Input, kW Wet Bulb Temp., (oC) Dry Bulb Temp., (oC) Indoor Outdoor Capacity Correction Factors Heating Capacity Ratio Vs. Outdoor Temperature 1.20 Capacity Ration 1.10 1.00 0.90 0.80 0.70 0.60 0.50 -15 -10 -5 0 5 10 15 Outdoor WB Temperature [deg C] SM SX DCI 1-A.3 GB CONTENT 5-21 PERFORMANCE DATA & PRESSURE CURVES 5.8.5 Model: SX 30 DCI Cooling – Test Mode Suction Pressure [kPa] Suction Pressure Vs. Outdoor Temp. 1000 960 920 880 840 800 760 720 680 640 600 Indoor DB/WB 22/15 24/17 27/19 29/21 32/23 10 15 20 25 30 35 40 45 O Outdoor DB Temperature[ C] Discharge Pressure [kPa] Discharge Pressure Vs.Outdoor Temp. 3900 3700 3500 3300 3100 2900 2700 2500 2300 2100 1900 1700 1500 Indoor DB/WB 22/15 24/17 27/19 29/21 32/23 10 15 20 25 30 35 40 45 O Outdoor DB Temperature[ C] 5-22 CONTENT SM SX DCI 1-A.3 GB PERFORMANCE DATA & PRESSURE CURVES 5.8.6 Heating – Test Mode Suction Pressure [kPa] Suction Pressure Vs.Outdoor Temp. 1150 1050 950 850 750 650 550 450 350 250 Indoor DB 15 20 25 -15 -10 -5 0 5 10 15 Outdoor WB Temperature[OC] Discharge Pressure [kPa] Discharge Pressure Vs.Outdoor Temp. 3850 3600 3350 3100 2850 2600 2350 2100 1850 1600 Indoor DB 15 20 25 -15 -10 -5 0 5 10 15 O Outdoor WB Temperature[ C] SM SX DCI 1-A.3 GB CONTENT 5-23 PERFORMANCE DATA & PRESSURE CURVES 5.9 Capacity Correction Factor Due to Tubing Length 5.9.1 SX 80 DCI :Cooling 1.01 1.00 Capacity Ratio 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 Heating 5 Tube Length(m) Capacity Ratio 5.9.2 6 5 1.00 7 6 1.00 7.5 10 15 7.5 10 15 7 7.5 10 Tube length [m] 1.00 1.00 0.981 20 25 15 0.943 20 0.904 20 25 30 25 0.865 Heating 1.05 Capacity Ratio 1.00 0.95 0.90 0.85 0.80 5 6 7 30 Tube Length [m] 5-24 CONTENT SM SX DCI 1-A.3 GB SOUND LEVEL CHARACTERISTICS 6. SOUND LEVEL CHARACTERISTICS 6.1 Sound Pressure Level Unit 1m Wall Mic. Ground Figure 1 6.2 Soud Pressure Level Spectrum (Measured as Figure 1) SX 9 FAN SPEED SX 12 LINE HI ME LO SM SX DCI 1-A.3 GB CONTENT 6-1 SOUND LEVEL CHARACTERISTICS SX 18 SX 24 SX 30 FAN SPEED LINE HI ME LO 6-2 CONTENT SM SX DCI 1-A.3 GB SOUND LEVEL CHARACTERISTICS 6.3 Outdoor units Unit 1m Mic. Ground Figure 2 6.4 Sound Pressure Level Spectrum (Measured as Figure 2) GC 9 DCI Cooling GC 9 DCI Heating GC 12 DCI Cooling GC 12 DCI Heating SM SX DCI 1-A.3 GB CONTENT 6-3 SOUND LEVEL CHARACTERISTICS FAN SPEED GC 18 DCI Cooling GC 18 DCI Heating GC 24 DCI Cooling GC 24 DCI Heating LINE HI ME LO 6-4 CONTENT SM SX DCI 1-A.3 GB SOUND LEVEL CHARACTERISTICS GC 30 DCI Cooling FAN SPEED GC 30 DCI Heating LINE HI ME LO SM SX DCI 1-A.3 GB CONTENT 6-5 ELECTRICAL DATA 7. ELECTRICAL DATA 7.1 Single Phase Units MODEL SX 9 DCI SX 12 DCI SX 18 DCI SX 24 DCI SX 30 DCI To indoor To indoor To indoor To outdoor To outdoor Power Supply 1PH-230V50Hz 1PH-230V50Hz 1PH-230V50Hz 1PH-230V50Hz 1PH-230V50Hz Max Current, A 10 10 12 14 15 Inrush Current A 35 35 35 45 45 Starting Current A 10.5 10.5 10.5 10.5 10.5 Circuit Breaker A 16 16 20 20 20 Power Supply Wiring No.X Cross Section mm2 3 x 1.5 mm2 3 x 1.5 mm2 3 x 2.5 mm2 3 x 2.5 mm2 3 x 2.5 mm2 Interconnecting Cable No.X Cross Section mm2 4 x 1.5 mm2 4 x 1.5 mm2 4 x 2.5 mm2 4 x 2.5 mm2 4 x 2.5 mm2 NOTE Power wiring cord should comply with local lows and electrical regulations requirements. SM SX DCI 1-A.3 GB CONTENT 7-1 B la c k Red B ro w n U V W W h it e P1 4 P4 1 2 P1 1 2 1 2 3 4 5 6 P16 P17 P18 P21 P22 P2 1 2 OAT P19 1 2 CONTENT Blue R ed Black L-F N-F COM NCOM L N COM E AR TH E AR TH FUSE Brown Red Y/G magnetic ring N/3 L/4 C/5 B lu e Brown Red Y/G POWE R SU PPL Y Blue Brown Red Y/G SX 9, 12, 18 DCI / GC 9, 12, 18 DCI EEV 8.1 Y/G P6 1 2 3 4 WIRING DIAGRAMS EMI f i l t er PCB 1 2 3 4 5 6 EARTH L N COM N-COM megatool P8 1 2 D i sp l ay 8. Y/G P7 6 5 4 3 2 1 J P9 P1 2 P10 P20 1 2 OCT CTT SUCT Outdoor unit controller PCB P3 P9 P11 P13 heater V dc Red Ba s e B la c k Choke coil B lu e OFAN EARTH V cc V sp O ra n g e Reverse valve B lu e SM SX DCI 1-A.3 GB Y e llo w COMP FG OUTDOOR UNIT CIRCUIT DIAGRAM WIRING DIAGRAMS 8-1 WIRING DIAGRAMS 8.2 8-2 Indoor Unit: SX 24, 30 DCI CONTENT SM SX DCI 1-A.3 GB WIRING DIAGRAMS 8.3 Outdoor Unit: GC 24, 30 DCI SM SX DCI 1-A.3 GB CONTENT 8-3 REFRIGERATION DIAGRAMS 9. REFRIGERATION DIAGRAMS 9.1 SX 9, 12, 18, 24, 30 DCI Cooling Mode EEV Heating Mode EEV SM SX DCI 1-A.3 GB CONTENT 9-1 TUBING CONNECTIONS 10. TUBING CONNECTIONS TUBE (Inch) ¼” ⅜” ½” ⅝” ¾” 11-13 13-20 11-13 40-45 13-20 11-13 60-65 18-25 11-13 70-75 18-25 11-13 80-85 40-50 11-13 TORQUE (Nm) Flare Nuts Valve Cap Service Port Cap 1. 2. 3. 4. 5. 6. 7. 8. Valve Protection Cap-end Refrigerant Valve Port (use Allen wrench to open/close) Valve Protection Cap Refrigerant Valve Service Port Cap Flare Nut Unit Back Side Copper Tube When the outdoor unit is installed above the indoor unit an oil trap is required every 5m along the suction line at the lowest point of the riser. Incase the indoor unit is installed above the outdoor, no trap is required. SM SX DCI 1-A.3 GB CONTENT 10-1 TROUBLESHOOTING 11. TROUBLESHOOTING WARNING!!! When Power Up – the whole outdoor unit controller, including the wiring, is under HIGH VOLTAGE!!! Never open the Outdoor unit before turning off the Power!!! When turned off, the system is still charged (400V)!!! It takes about 3 Min. to discharge the system. Touching the controller before discharging may cause an electrical shock!!! For safe handling of the controller please refer to section 11.6 below. 11.1 General DCI Single Split System failures and Corrective Actions PROBABLE CAUSE No SYMPTOM 1 Power supply indicator (Red LED) does not light up. No power supply Check power supply. If power supply is OK, check display and display wiring. if OK, replace controller. 2 Unit does not respond to remote control message Remote control message not reached the indoor unit Check remote control batteries, if batteries are OK, check display and display wiring, if OK, replace display PCB. If still not OK replace controller. 3 Unit responds to remote control message but Operate indicator (Green LED) does not light up Problem with display PCB Replace display PCB. If still not OK replace controller. Unit in heat mode and coil is still not warm. Change to cool mode and check. Problem with PCB or capacitor Change to high speed and Check power supply to motor is higher than 130VAC (for triack controlled motor) or higher than 220VAC for fixed speed motors, if OK replace capacitor, if not OK replace controller 5 Indoor fan works when unit is OFF, and indoor fan speed is not changed by remote control command. PCB problem Replace controller 6 Compressor does not start Electronics control problem or protection Perform diagnostics (See 11.3), and follow the actions described. 7 Compressor stops during operation and Green LED remains on Electronic control or power supply problem Perform diagnostics (See 11.3), and follow the actions described. 4 Indoor fan does not start (louvers are opened and Green LED does light up) SM SX DCI 1-A.3 GB CONTENT CORRECTIVE ACTION 11-1 TROUBLESHOOTING No SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION 8 Compressor is on but outdoor fan does not work Problem with outdoor electronics or outdoor fan Check outdoor fan motor according to the procedure in section 11.5.3 , if not OK replace controller 9 Unit works in wrong mode (cool instead of heat or heat instead of cool) Electronics or power connection to RV Check RV power connections, if OK, Check RV operation with direct 230VAC power supply, if OK, Replace outdoor controller. 10 All components are operating properly but no cooling or no heating Refrigerant leak Check refrigeration system. 11 Compressor is over heated and unit does not generate capacity EEV problem Check EEV 12 Units goes into protections and compressor is stopped with no clear reason Control problem or refrigeration system problem Perform diagnostics (See 11.3), and follow the actions described. 13 Compressor motor generating noise and suction occurs Phase order to compressor is wrong Check compressor phase order. 14 Water leakage from indoor unit Indoor unit drainage tube is blocked Check and open drainage tube. 15 Freezing of outdoor unit in heat mode and outdoor unit base is blocked with ice 16 Unit operates with wrong fan speeds or wrong frequency 11.2 is no Connect base heater. Wrong jumper settings Perform diagnostics (See 11.3), and check if units is operating by EEPROM parameters. Checking the refrigeration system Checking system pressures and other thermodynamic measures should be done when system is in Test Mode (in Test mode, system operates in fixed settings). The performance curves given in this manual are given for unit performance in test mode when high indoor fan speed is selected. Entering test mode: Set unit to Cool/16 degrees/High indoor fan speed, or Heat/30 degrees/High indoor fan speed, and enter diagnostics. 11.3 Judgment by Indoor/Outdoor Unit Diagnostics Enter diagnostics mode - press for five seconds Mode button in any operation mode. Acknowledgment is by 3 short beeps and lights of COOL and HEAT LED’s. Then, every short pressing of Mode button will scroll between Indoor and Outdoor unit diagnostic modes by the acknowledgment of 3 short beeps and lighting of COOL and HEAT LED’s. During the Outdoor unit diagnostics all four Indoor LED’s (STBY, Operate, Filter and Timer) are blinking. When Indoor diagnostics is displayed, all four LED’s (STBY, Operate, Filter and Timer) are ON. 11-2 CONTENT SM SX DCI 1-A.3 GB TROUBLESHOOTING When system enters diagnostics mode, only one fault code is shown. Order of priority is from the lower to the higher number. Diagnostics is continuously ON as long as power is ON. The current system operation mode will not be changed. If no fault occurred in the system, no fault code will be displayed during normal operation mode. The last fault code will be displayed even if the system has recovered from that fault. The last fault will be deleted from the EEPROM after the system has exit diagnostics mode. In diagnostics mode, system fault / status will be indicated by blinking of Heat & Cool LEDs. The coding method will be as follows: Heat LED will blink 5 times in 5 seconds, and then will be shut off for the next 5 seconds. Cool LED will blink during the same 5 seconds according to the following Indoor / Outdoor unit tables: Note: 0 – OFF, 1-ON 11.3.1 Indoor Unit Diagnostics ● Alarm Output The Alarm Output dry contact will be on (closed), when a predefined set faults occur. The fault set is defined under diagnostics section. The alarm output will be off (open), when the predefined fault is cleared. The indoor alarm outputs are defined according to the following table: No Problem AO 5 4 3 2 1 1 ICT is disconnected Yes 0 0 0 0 1 2 ICT is shorted Yes 0 0 0 1 0 3 RAT is disconnected Yes 0 0 0 1 1 4 RAT is shorted Yes 0 0 1 0 0 5 Reserved (for MSMP used as RGT fault) No 0 0 1 0 1 ICTE shorted/disconnected (when enabled) Yes 0 0 1 1 0 Undefined IDU family/model Yes 0 0 1 1 1 8 No Communication Yes 0 1 0 0 0 9 No Encoder No 0 1 0 0 1 10 Reserved No 0 1 0 1 0 11 Outdoor Unit Fault No 0 1 0 1 1 … Reserved No 17 Defrost protection No 1 0 0 0 1 18 Deicing Protection No 1 0 0 1 0 19 Outdoor Unit Protection No 1 0 0 1 1 20 Indoor Coil HP Protection No 1 0 1 0 0 21 Overflow Protection Yes 1 0 1 0 1 22 Reserved No 24 EEPROM Not Updated No 1 1 0 0 0 25 Bad EEPROM No 1 1 0 0 1 26 Bad Communication No 1 1 0 1 0 27 Using EEPROM data No 1 1 0 1 1 *6 *7 SM SX DCI 1-A.3 GB CONTENT 11-3 TROUBLESHOOTING No Problem AO 5 4 3 2 1 28 Model A No 1 1 1 0 0 29 Model B No 1 1 1 0 1 30 Model C No 1 1 1 1 0 31 Model D No 1 1 1 1 1 * CN / LSN Units only 11.3.2 Indoor Unit Diagnostics and Corrective Actions No. Fault Probable Cause Corrective Action 1 Sensor failures of all types Check sensor connections or replace sensor 2 Communication mismatch Indoor and Outdoor controllers are with different versions Replace Indoor controller 3 No Communication Communication or grounding wiring is not good. Check Indoor to Outdoor wiring and grounding 4 No Encoder Indoor electronics or motor Check motor wiring, if ok, replace motor, if still not ok, replace Indoor controller. 5 Outdoor Unit Fault Outdoor controller problem Switch to Outdoor diagnostics. 6 EEPROM Not Updated System is using ROM parameters and not EEPROM parameters No action, unless special parameters are required for unit operation. 7 Bad EEPROM 8 Bad Communication Communication quality is low reliability 9 Using EEPROM data No problem. System is using EEPRRRROM parameters No action, unless special parameters are required for unit operation. Check Indoor to Outdoor wiring and grounding 11.3.3 Outdoor Unit Diagnostics The outdoor alarm outputs are defined in the following way: No Problem AO 5 4 3 2 1 1 OCT is disconnected Yes 0 0 0 0 1 2 OCT is shorted Yes 0 0 0 1 0 3 CTT is disconnected Yes 0 0 0 1 1 4 CTT is shorted Yes 0 0 1 0 0 5 HST is disconnected (when enabled) Yes 0 0 1 0 1 6 HST is shorted (when enabled) Yes 0 0 1 1 0 7 OAT is disconnected (when enabled) Yes 0 0 1 1 1 8 OAT is shorted (when enabled) Yes 0 1 0 0 0 9 OMT is disconnected (DCI72 / 72Z / 80) Yes 0 1 0 0 1 11-4 CONTENT SM SX DCI 1-A.3 GB TROUBLESHOOTING No Problem AO 5 4 3 2 1 10 OMT is shorted (DCI72 / 72Z / 80) Yes 0 1 0 1 0 11 IPM Fault Yes 0 1 0 1 1 12 Bad EEPROM No 0 1 1 0 0 13 DC under voltage Yes 0 1 1 0 1 14 DC over voltage Yes 0 1 1 1 0 15 AC under voltage Yes 0 1 1 1 1 16 Mismatch IDU & ODU models (*SW 35V14 and above) Yes 1 0 0 0 0 17 No Communication Yes 1 0 0 0 1 18 Reserved No 1 0 0 1 0 20 Heat sink Over Heating No 1 0 1 0 0 21 Deicing No 1 0 1 0 1 22 Compressor Over Heating No 1 0 1 1 0 23 Compressor Over Current No 1 0 1 1 1 24 No OFAN Feedback No 1 1 0 0 0 25 OFAN locked Yes 1 1 0 0 1 26 Compressor Lock Yes 1 1 0 1 0 27 Bad Communication No 1 1 0 1 1 28 Missing ODU configuration (*SW 35V14 and above) Yes 1 1 1 0 0 29 Undefined ODU Model (*SW 35V14 and above) Yes 1 1 1 0 1 30 For future use No 1 1 1 1 0 31 Operation condition is exceeded (*SW 35V14 and above) Yes 1 1 1 1 1 *Alarm Output - is on SW 35V14 and above. There is no alarm on SW 35V12 and below/ 11.3.4 Outdoor Unit Diagnostics and Corrective Actions No. Fault 1 Sensors failures of all types Check sensors connections or replace sensors. 2 IPM Fault Check all wiring and jumper settings, if OK, replace electronics. 3 Bad EEPROM 4 DC under/over Voltage 5 AC under Voltage 6 Indoor / Outdoor unit Communication mismatch Indoor and Outdoor controllers are with different versions Replace Indoor controller No Communication Communication or grounding wiring is not good. Check Indoor to Outdoor wiring and grounding 7 SM SX DCI 1-A.3 GB Probable Cause Electronics HW problem Corrective Action No action, unless special parameters are required for unit operation. Electronics HW problem Check outdoor unit power supply voltage Check outdoor unit power supply voltage CONTENT 11-5 TROUBLESHOOTING No. Fault 8 Compressor Lock 9 Bad Communication 11.4 Probable Cause Corrective Action Switch unit to STBY and restart If still not ok check compressor (11.5.4) If comp is ok replace OU controller If compressor is not ok replace compressor Communication quality is low reliability Check Indoor to Outdoor wiring and grounding Judgment by MegaTool MegaTool is a special tool to monitor the system states. Using MegaTool requires: • • • A computer with RS232C port. • • Setup MegaTool software: copy the software to the computer. • Run the software and choose the COM port, you can monitor the A/C system state in monitor tab. A connection wire for MegaTool. A special MegaTool software. Use MegaTool according to following procedure: Connect RS232C port in computer with MegaTool port in Indoor/Outdoor unit controller by the connection wire. 11.5 Simple procedures for checking the Main Parts 11.5.1 Checking Mains Voltage. Confirm that the Mains voltage is between 198 and 264 VAC. If Mains voltage is out of this range, abnormal operation of the system is expected. If in range check the Power (Circuit) Breaker and look for broken or loosed cable lugs or wiring mistake(s). 11.5.2 Checking Power Input. If Indoor unit power LED is unlighted, power down the system and check the fuse of the Indoor unit. If the fuse is OK replace the Indoor unit controller. If the fuse has blown, replace the fuse and power up again. Checking Power Input procedure for the Outdoor unit is the same as with the Indoor unit. 11.5.3 Checking the Outdoor Fan Motor. Enter Test Mode (where the OFAN speed is high) Check the voltage between lead wires according to the normal value as following: • • • 11-6 Between red wire and black wire: 310VDC +/- 20V Between orange wire and black wire: 15VDC +/- 1V Between yellow wire and black wire: 2-6VDC CONTENT SM SX DCI 1-A.3 GB TROUBLESHOOTING 11.5.4 Checking the Compressor. The compressor is brushless permanence magnetic DC motor. Three coil resistance is same. Check the resistance between three poles. The normal value should be below 0.5 ohm (TBD). 11.5.5 Checking the Reverse Valve (RV). Running in heating mode, check the voltage between two pins of reverse valve connector, normal voltage is 220VAC. 11.5.6 Checking the electrical expansion valve (EEV). The EEV has two parts, drive part and valve. The drive part is a step motor; it is ringed on the valve. Check the drive voltage (12VDC). When Outdoor unit is power on, EEV shall run and have click and vibration. 11.6 Precaution, Advise and Notice Items 11.6.1 High voltage in Outdoor unit controller. Whole controller, including the wires that are connected to the Outdoor unit controller may have the potential hazard voltage when power is on. Touching the Outdoor unit controller may cause an electrical shock. Advise: Don’t touch the naked lead wire and don’t insert finger, conductor or anything else into the controller when power is on. 11.6.2 Charged Capacitors Three large-capacity electrolytic capacitors are used in the Outdoor unit controller. Therefore, charging voltage (380VDC) remains after power down. Discharging takes about four minutes after power is off. Touching the Outdoor unit controller before discharging may cause an electrical shock. 11.6.3 w Additional advises • • When disassemble the controller or the front panel, turn off the power supply. • There are sharp fringes and sting on shell. Use gloves when disassemble the A/C units. When connecting or disconnecting the connectors on the PCB, hold the whole housing, don’t pull the wire. SM SX DCI 1-A.3 GB CONTENT 11-7 CONTROL SYSTEM 12. CONTROL SYSTEM 12.1 General Functions and Operating Rules The DCI software is fully parametric. All the model dependent parameters are shown in Blue color and with Italic style [parameter]. The parameters values are given in the last section of this control logic chapter of the service manual. 12.1.1 System Operation Concept The control function is divided between indoor and outdoor unit controllers. Indoor unit is the system ‘Master’, requesting the outdoor unit for cooling/heating capacity supply. The outdoor unit is the system ‘Slave’ and it must supply the required capacity unless it enters into a protection mode avoiding it from supplying the requested capacity. The capacity request is transferred via indoor to outdoor communication, and is represented by aparameter called ‘NLOAD’. NLOAD is an integer number with values between 0 and 127, and it represents the heat or cool load felt by the indoor unit. 12.1.2 Compressor Frequency Control 12.1.2.1 NLOAD setting The NLOAD setting is done by the indoor unit controller, based on a PI control scheme. The actual NLOAD to be sent to the outdoor unit controller is based on the preliminary LOADcalculation, the indoor fan speed, and the power shedding function. NLOAD limits as a function of indoor fan speed: Indoor Fan Speed Maximum NLOAD Cooling Maximum NLOAD Heating Indoor Fan Speed Low Medium High Turbo Auto Maxium NLOAD Cooling Maxium NLOAD Heating MaxNLOADIF1C MaxNLOADIF2C MaxNLOADIF3C MaxNLOADIF4C MaxNLOADIF5C MaxNLOADIF1H MaxNLOADIF2H MaxNLOADIF3H MaxNLOADIF4H MaxNLOADIF5H NLOAD limits as a function of power shedding: Mode Cooling Heating 12.1.3 Power Shedding OFF No limit No limit Power Shedding ON Nominal Cooling Nominal heating Target Frequency Setting 12.1.3.1 Target Frequency Setting for DCI 50/60/72Z The compressor target frequency is a function of the NLOAD number sent from the indoor controller and the outdoor air temperature. Basic Target Frequency Setting: NLOAD 127 10<NLOAD<127 10 0 SM SX DCI 1-A.3 GB Target Frequency Maximum Frequency Interpolated value between minimum and maximum frequency Minimum frequency Compressor is stopped CONTENT 12-1 CONTROL SYSTEM Target frequency limits as a function of outdoor air temperature (OAT): OAT Range Cooling Mode limits OAT < 6 Heating Mode limits No limit 6 ≤ OAT < 15 MaxFreqAsOAT1H MaxFreqAsOATC 15 ≤ OAT < 28 28≤ OAT MaxFreqAsOAT2H No limit 12.1.3.2 Target Frequency Setting for DCI 72/80 The compressor Target Speed is calculated according to the following formula: ODUNload T arg et Speed load max MinSpeed , MaxSpeed 127 MiniSpeed, MaxSpeed are defined as following: When the unit is in the cool mode, MiniSpeedC = 15Hz, MaxSpeed = 75Hz When the unit is in the heat mode, MiniSpeedH = 20Hz, MaxSpeed = 95Hz ODU NLOAD is caculated according to the IDU NLoad: 3 * IDUNLOAD ODU NLOAD min , 127 ODUCode OAT ≤-5 ≤-5 12.1.4 ODUCodeC 3 3.8 ODUCodeC 3 3 IDUNLOAD Refer to sect.112.1.2.1 Frequency Changes Control When the unit is running normally , the compressor frequency change rate is 1 Hz/sec. 12.1.5 Compressor Starting Control 12.1.5.1 Compressor starting control for DCI50/60/72Zzz Step3 Step2 Step1 1 Minute 12-2 1 Minute Time Min 10 Minutes CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM 12.1.5.2 Compressor starting control for DCI72/80 Step 1 Whenever the compressor starts up, after it has been off for more than 45 minutes, the compressor frequency cannot go below Step1RPS for 3 continuous minutes (this rule comes to ensure oil return to the compressor). Step 2 The compressor speed cannot go above Step2RPS once after each compressor start up for 3 continuous minutes (this rule comes to prevent oil exit from the compressor after its start up). Step 3 The speed cannot go higher than Step3RPS unless it was operating for more than 1 continuous minutes between Step3RPS – 5 and Step3RPS . After passing above Step3RPS, this rule is re-applied when passing below Step3RPS-5. 12.1.6 Minimum On and Off Time 3 minutes 12.1.7 Indoor Fan Control 8 Indoor fan speeds are determined for each model. 4 speeds for cool/dry/fan modes and 4 speeds for heat mode. When user sets the indoor fan speed to a fixed speed (Low/ Medium/ High), unit will operate constantly at set speed. When Auto Fan is selected, indoor unit controller can operate in all speeds. The actual speed is set according to the cool/heat load. 12.1.7.1 Turbo Speed The Turbo speed is activated during the first 30 minutes of unit operation when auto fan speed is selected and under the following conditions: Difference between set point and actual room temperature is bigger then 3 degrees. Room temperature > 22 for cooling, or < 25 for heating. 12.1.8 Outdoor Fan Control 12.1.8.1 Outdoor Fan Control for DCI50/60 7 outdoor fan speeds are determined for each model. 3 speeds for cool and dry modes, and 3 speeds for heat mode, and a very low speed. Outdoor fan speed is a function of compressor frequency and outdoor air temperature (OAT). 4 routines for fan control are determined. The control routine selection depends on operation mode, compressor speed, outdoor air temperature (OAT) and heat sink temperature (HST). Routine Conditions B Heating with OAT < 15°C or Cooling with OAT > 20°C, or Faulty OAT Cooling with 20°C > OAT > 7°C C Cooling with 7°C > OAT D Heating with OAT > 15°C A SM SX DCI 1-A.3 GB CONTENT 12-3 CONTROL SYSTEM OFAN Speed Compressor Target Frequency Routin A Routin B Routin C Routin D Freq=0 OFF OFF OFF OFF 10 ≤ Freq < OFLowFreq Low Low VL Low OFLowFreq ≤ Freq< OFMedFreq Medium Low VL Low OFMedFreq≤ Freq High Low Low Medium When compressor is switched to OFF and the heat sink temperature is above 55 degrees, the outdoor fan will remain ON in low speed for up to 3 minutes. OFAN State at Cool Mode HST Change To Higher OFAN Cool state (*1) 3 Degrees A 3 Degrees B 50 C 7 20 OAT 45 Change To lower OFAN Cool state Note: Periorities A>B>C (*1) If State C, change to B If State B, change to A 12.1.8.2 Outdoor Fan Control for GC 24, 30 DCI OFAN operates between any speed OFMinRPM to OFMaxRPM. The fan speed is also related to protections and OMT value. * For DCI 72Z, in heating mode the OFAN speed is related to OCT. 12.1.9 EEV (Electronic Expansion Vavle) Control 12.1.9.1 EEV Control for GC 9, 12, 18 DCI EEV opening is defined as EEV = EEVOL + EEVCV EEVOL is the initial EEV opening as a function of the compressor frequency, operation mode, unit model and capacity. EEVCV is a correction value for the EEV opening that is based on the compressor temperature. During the first 5 minutes of compressor operation EEVCV = 0. Once the first 5 minutes are over, the correction value is calculated as follow: EEVCV(n) = EEVCV(n-1) + EEVCTT EEVCTT is the correction based on the compressor temperature. A target compressor temperature is set depending on frequency and outdoor air temperature, and the actual compressor temperature is compared to the target temperature to set the required correction to the EEV opening. 12-4 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM 12.1.9.2 EEV Control for DCI72/72Z/80 The target EEV value is the sum of open loop value (OL) and a result of the accumulative correction values (CV). EEV EEVOL EEVCV The EEV intial value(OL) is defined as follow: EEVOL= EEVBaseOpenLoop + EEVOpenLoopCpctyCrct + EEVTubeCompnst Basic EEV open loop Open Loop correction EEV tube Length compensation Mode 72/80 72/80 72/80 COOL 220 25 0 HEAT 170 30 0 *For DCI72Z The initial EEVOL is defined in accordance to the compressor frequency EEVCV is a correction value for the EEV opening that is based on the compressor temperature, During the first 6 minutes after SB the correction is not calculated. After that the correction value is updated every 30 seconds. 12.1.10 RV(Reversing Valve) Control Reversing valve is on in heat mode. Switching of RV state is done only after compressor is off for over 3 minutes. 12.1.11 Ioniser Control Ioniser is on when unit is on ,AND indoor fan is on ,AND Ioniser power switch (on Ioniser) is on. 12.1.12 Base Heater Control The base heater will be working only when RV is “ON” according to the following graph: Base Heater OFF ON 0 2 OAT When OAT is faulty the base heater will be “ON” continuously in HEAT mode. 12.2 Fan Mode In high/ medium/ low indoor fan user setting, unit will operate fan in selected speed. In AutoFan user setting, fan speed will be adjusted automatically according to the differencebetween actual room temperature and user set point temperature. SM SX DCI 1-A.3 GB CONTENT 12-5 CONTROL SYSTEM 12.3 Cool Mode NLOAD is calculated according to the difference between actual room temperature and user set point temperature by PI control. In high/ medium/ low indoor fan user setting, unit will operate fan in selected speed. In AutoFan user setting, fan speed will be adjusted automatically according to the calculated NLOAD. 12.4 Heat Mode NLOAD is calculated according to the difference between actual room temperature and user set point temperature by PI control. In high/ medium/ low indoor fan user setting, unit will operate fan in selected speed. In AutoFan user setting, fan speed will be adjusted automatically according to the calculated NLOAD. 12.4.1 Temperature Compensation In wall mounted, ducted, and cassette models, 3 degrees are reduced from room temperature reading (except when in I-Feel mode), to compensate for temperature difference between high and low areas in the heated room, and for coil heat radiation on room thermistor. The temperature compensation can be enabled/disabled by shortening of J2 on the indoor unit Controller Model J2 Shorted J2 Opened Wall mounted Cassette Compensation Disabled Compensation Enabled Compensation Enabled Compensation Disabled Ducted Floor/Ceiling Compensation Enabled Compensation Disabled Compensation Disabled Compensation Enabled 12.4.2 Indoor Fan Control in Heating Mode Indoor fan speed depends on the indoor coil temperature: 12.5 Auto Cool/Heat Mode When in auto cool heat mode unit will automatically select between cool and heat mode according to the difference between actual room temperature and user set point temperature (.T). Unit will switch from cool to heat when compressor is off for 3 minutes, and .T < -3. Unit will switch from heat to cool when compressor is off for 5 minutes, and .T < -3. 12-6 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM 12.6 Dry Mode As long as room temperature is higher then the set point, indoor fan will work in low speed and compressor will work between 0 and MaxNLOADIF1C Hz. When the room temperature is lower than the set point, compressor will be switched OFF and indoor fan will cycle 3 minutes OFF, 1 minute ON. 12.7 Protections There are 5 protection codes. Normal (Norm) – unit operate normally. Stop Rise (SR) – compressor frequency can not be raised but does not have to be decreased. HzDown1 (D1) – Compressor frequency is reduced by 2 to 5 Hz per minute. HzDown2 (D2) – Compressor frequency is reduced by 5 to 10 Hz per minute. Stop Compressor (SC) – Compressor is stopped. 12.7.1 Indoor Coil Defrost Protection ICT Trend ICT Fast Increasing Increasing No Change Decreasing Fast ICT< -2 -2 ≤ ICT<0 0 ≤ ICT < 2 2 ≤ ICT< 4 4 ≤ ICT < 6 6 ≤ ICT ≤ 8 ICT> 8 SC D1 SR SR Norm Norm SC D1 SR SR Norm Norm SC D2 D1 SR SR Norm Norm SC D2 D2 D1 SR SR SC D2 D2 D2 D1 SR 12.7.2 Indoor Coil Overheating Protection 12.7.2.1 Indoor Coil Overheating Protection For 50/60/72Z ICT Trend ICT Fast Decreasing Decreasing No Change Increasing Fast Increasing ICT >62 60 ≤ ICT < 62 55≤ ICT <60 52≤ ICT < 55 48≤ ICT < 52 45≤ ICT ≤ 48 ICT <45 SC D1 SR SR Norm Norm SC D1 SR SR Norm Norm SC D2 D1 SR SR Norm Norm SC D2 D2 D1 SR SR SC D2 D2 D2 D1 SR SM SX DCI 1-A.3 GB CONTENT 12-7 CONTROL SYSTEM 12.7.2.2 Indoor Coil Overheating Protection For 72/80 ICT Trend ICT <-2 -2 -1,0,1 2 >2 ICT >62 SC SC SC SC SC 60 ≤ ICT < 62 D1 D1 D2 D2 D2 58≤ ICT <60 SR SR D1 D2 D2 56≤ ICT < 58 SR SR SR D1 D2 54≤ ICT < 56 Norm Norm SR SR D1 52≤ ICT ≤ 54 Norm Norm Norm SR SR ICT <52 12.7.3 Norm Compressor Overheating Protection 12.7.3.1 Compressor Overheating Protection for DCI50/60/72Z Compressor temperature can be in one of 5 control zones (4 in protection, and 1 normal),according to the following chart. CTT 105 102 98 94 Stop-Compressor P3 P2 P1 Normal Control Status Compressor Temperature Increases Else P1 Normal Stop Rise P2 HzDown 1 Stop Rise P3 HzDown 2 HzDown 1 Stop Compressor Stop Compressor 12-8 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM 12.7.3.2 Compressor Overheating Protection for DCI72/80 CTT Trend CTT Fast Decreasing Decreasing No Change Increasing Fast Increasing CTT >105 100≤ CTT < 105 95≤CTT <100 SC SC SC SC SC D1 D1 D2 D2 D2 SR SR D1 D2 D2 93≤CTT < 100 85≤CTT < 95 SR SR SR D1 D1 90≤CTT ≤ 93 80≤CTT ≤ 85 Norm Norm Norm SR SR CTT <90 CTT <80 Cool Heat CTT >105 100≤ CTT < 105 98≤CTT <100 12.7.4 Norm Compressor Over Current Protection Only For DCI50/60/72Z CCR Stop-Compresor CCROC4 HzDown2 CCROC3 HzDown1 CCROC2 Stop-Rise CCROC1 Normal 12.7.5 Heat Sink Overheating Protection 12.7.5.1 Heat Sink Overheating Protection For DCI50/60/72Z HST Trend HST Fast Decreasing Decreasing No Change Increasing Fast Increasing HST ≥ 90 SC SC SC SC SC 85 ≤ HST < 90 D1 D1 D2 D2 D2 82 ≤ HST < 85 SR SR D1 D2 D2 80≤ HST< 82 SR SR SR D1 D1 78 ≤ HST ≤ 80 Norm Norm Norm SR SR HST < 78 SM SX DCI 1-A.3 GB Norm CONTENT 12-9 CONTROL SYSTEM 12.7.5.2 Heat Sink Overheating Protection For DCI72/80 Delta HST HST <-2 -2 -1,0,1 2 >2 HST≥ 81 SC SC SC SC SC 79 ≤ HST < 81 D1 D1 D2 D2 D2 75 ≤ HST < 79 SR SR D1 D2 D2 73≤ HST< 75 SR SR SR D1 D1 71 ≤ HST ≤ 73 Norm Norm Norm SR SR HST < 71 12.7.6 Norm System Over Power Protection Only For DCI72/80 Delta PWR Power < -2000 [-2000,0) 0 (0,2000] > 2000 PWR ≥ 2900 SC SC SC SC SC 3300≤PWR < 3500 2750≤PWR < 2900 D1 D1 D2 D2 D2 3100 ≤PWR < 3300 2600≤PWR < 2750 SR SR D1 D2 D2 3000≤PWR < 3100 2450≤PWR < 2600 2300 ≤PWR ≤ 2450 PWR < 2300 SR SR SR D1 D1 Norm Norm Norm SR SR PWR1 PWR ≥ 3500 2950 ≤PWR ≤ 3000 PWR < 2950 PWR2 Norm There are two sets of OVRPWR values, the selection of the values are set according to the state of the Power-Shed input. Power-Shed input open Set values 1 Power-Shed input sort Set values 2 12.7.7 Outdoor Coil Deicing Protection 12.7.7.1 Outdoor coil Deicing Protection For DCI50/60/72Z ► Entering Deicing Conditions Deicing operation will start when either one of the following conditions exist: Case 1: OCT < OAT – 8 AND TLD > DI Case 2: OCT < OAT – 12 AND TLD > 30 minutes. Case 3: OCT is Invalid AND TLD > DI Case 4: Unit is just switched to STBY AND OCT < OAT – 8 Case 5: NLOAD = 0 AND OCT < OAT -8 Case 6: OCT<-19 AND TLD>60 minutes All this condition will exist during 10 seconds OCT – Outdoor Coil Temperature OAT – Outdoor Air Temperature TLD – Time from Last Deicing DI – Deicing Interval (Time Interval Between Two Deicing) Deicing interval time when compressor is first started in heat mode, is 10 minutes if OCT < -2, and is 40 minutes in other cases. Deicing interval time is changed (increased/ decreased in 10 minutes steps) as a function of deicing time. If deicing time is shorter then former deicing time, the deicing interval time will be increased. If deicing time is longer then former deicing time, the deicing interval time will be decreased. 12-10 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM Deicing Operation Procedure ► OCT 12 0 T h re s h o ld COMP ON T1 T2 DT m a x. 1 2 m in u te s D e ic e F re q C h R V RV HEAT COOL O FAN T1 T3 T3 ON OFF EEV E E V D e ic e rO p e n Any T1=60 secondes;T2=36 secondes;T3=6 secondes 12.7.7.2 Outdoor coil Deicing Protection For DCI72/80 Entering Deicing Conditions Deicing operation will start when either one of the following conditions exist: Case 1: OCT < OAT – 8 AND TLD > DI Case 2: OCT < OAT – 12 AND TLD > 30 minutes. Case 3: OCT is Invalid AND TLD > DI Case 4: Unit is just switched to STBY AND OCT < OAT – 8 Case 5: NLOAD = 0 AND OCT < OAT - 8 Case 6: OAT is invalid AND OCT< 8 AND TLD > DI AND Compressor ON Time > 15 minutes All this condition will exist during 400 seconds OCT – Outdoor Coil Temperature OAT – Outdoor Air Temperature TLD – Time from Last Deicing DI – Deicing Interval (Time Interval between Two Deicing) Deicing interval time when compressor is first started in heat mode, is 10 minutes if OCT < -2, and is 40 minutes in other cases. Deicing interval time is changed (increased/ decreased in 10 minutes steps) as a function of deicing time. If deicing time is shorter then former deicing time, the deicing interval time will be increased. If deicing time is longer then former deicing time, the deicing interval time will be decreased. ► SM SX DCI 1-A.3 GB CONTENT 12-11 CONTROL SYSTEM Deicing Operation Procedure ► OCT 12 0 Threshold COMP ON T1 T2 T1 max. 12 minutes DT HEAT RV T3 COOL OFAN T3 ON OFF EEVDeicerOpen EEV Any T1=50 secondes;T2=36 secondes;T3=6 secondes 12.7.8 Condensate Water Over Flow Protection Each of the pins P1, P2, P3 can have two options: 1 – When it is shorted with P4 0 – When it is not shorted to P4 ► Water Level Protection-1 level P1 P2 P3 Level Don’t care Don’t care 1 Normal Don’t care Don’t care 0 Overflow (*) 1- Pin P1, P2, or P3 is connected to P4. 0- Pin P1, P2 or P3 is not connected to P4. 12-12 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM Overflow when unit is ON Overflow Water Level Overflow when unit is OFF Normal ON OPER LED OFF BLINK ANY NLOAD NLOAD is forced to 0 0 ON PUMP OFF 8 min 12.8 8 min 8 min Indoor Unit Dry Contact Indoor unit Dry contact has two alternative functions that are selected by J9. Function Contact=open Contact=short J9=open Presence Detector Connection No limit Force to STBY J9=short Power Shedding Function No limit Limit NLOAD 12.9 Operating the Unit from Mode Button Forced operation allows to start, stop and operate in Cooling or Heating, in pre-set temperature according to the following table: Forced operation Mode Pre-set Temperature Cooling 20°C Heating 28°C SM SX DCI 1-A.3 GB CONTENT 12-13 CONTROL SYSTEM 12.10 On Unit Controls and Indicators 12.10.1 Indoor Unit controller Controls and Indicatiors for All Models Except for Floor/Ceiling model During OFF, Fan, Cool, Heat, Dry, and Auto modes (for operation in other modes, see at the relevant spec paragraph): STAND BY INDICATOR 1. Lights up when the Air Conditioner is connected to power and ready to receive the R/C commands OPERATION INDICATOR 1. Lights up during operation. 2. Blinks for 300 msec., to announce that a R/C infrared signal has been received and stored. 3. Blinks continuously during protections (according to the relevant spec section). TIMER INDICATOR Lights up during Timer and Sleep operation. FILTER INDICATOR Lights up when Air Filter needs to be cleaned. COOLING INDICATOR Lights up when system is switched to Cool Mode by using the Mode Switch on the unit. HEATING INDICATOR Lights up when system is switched Heat Mode by using the Mode Switch on the unit. Mode SWITCH (COOL/HEAT/OFF) Every short pressing , the next operation mode is selected, in this order : SB → Cool Mode → Heat Mode → SB → … In long pressing system enters diagnostic mode. For short pressing: RESET / FILTER SWITCH When Filter LED is on - turn off the FILTER INDICATOR after a clean filter has been reinstalled. When Filter LED is off – enable/disable the buzzer announcer, if selected. In long pressing system enters set up mode (if in SB). 12.10.2 Outdoor Unit controller Indicatiors Unit has three LED’s. SB LED is ON when power is ON (230 VAC, even when no communication). STATUS LED is ON when COMP is ON, and Blinks according to diagnostics mode definitions when either fault or protection occurs. FAULT LED Blinks according to diagnostics mode definitions when either fault or protection occurs. 12-14 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM 12.11 Test Mode 12.11.1 Entering Test Mode System can enter Test mode in two ways: Automatically when the following conditions exists for 30 minutes continuously: Mode = Cool, Set point = 16, Room temperature = 27(+1/−2), Outdoor temperature = 35(+2/-1) Or Mode = Heat, Set point = 30, Room temperature = 20±1, Outdoor temperature = 7±(+1/-2) Manually when entering diagnostics with the following settings: Mode = Cool, Set point = 16 Mode = Heat, Set point = 30 12.11.2 Unit Operation in Test Mode In test mode, the unit will operate in fixed settings according to the indoor fan speed setting: Indoor FAN Speed Setting Unit Setting Low Minimum Capacity Setting Turbo Auto Nominal Capacity Setting Maximum Capacity Setting During test mode, protections are disabled, except for stop compressor status. 12.12 SW Parameters 12.12.1 Indoor Units SW Parameters Model dependent parametes - KN Cap .Group NomLoadC NomLoadH MaxNLOADIF1C MaxNLOADIF2C MaxNLOADIF3C MaxNLOADIF4C MaxNLOADIF5C MinRTC MaxNLOADRTC MaxNLOADIF1H MaxNLOADIF2H MaxNLOADIF3H MaxNLOADIF4H MaxNLOADIF5H MaxNLOADRTH MaxRTH MaxNLOADPSC MaxNLOADPSH SM SX DCI 1-A.3 GB A (KN-60) 3 81 77 55 70 127 127 127 20 127 127 127 127 127 127 127 27 81 77 B (KN-72) 4 61 59 44 50 120 127 127 20 127 127 127 127 127 127 127 27 61 59 C (KN-80) 4 67 67 85 102 120 127 127 20 127 127 127 127 127 127 127 27 67 67 CONTENT 12-15 CONTROL SYSTEM Model dependent parameters - DNG Unit A (DNG50) B (DNG60) C (DNG72) D (DNG80) 3 62 74 22 28 30 32 40 50 63 120 127 127 20 127 127 127 127 127 127 127 27 62 74 3 77 80 22 28 30 32 40 50 63 120 127 127 20 127 127 127 127 127 127 127 27 77 80 4 57 55 22 28 30 32 40 63 85 115 127 127 20 127 127 127 127 127 127 127 27 57 55 4 60 63 22 28 30 32 40 78 100 127 127 127 20 127 127 127 127 127 127 127 27 60 63 Cap .Group NomLoadC NomLoadH ICTSTSpeed ICTVLSpeed ICTLSpeed ICTHSpeed ICTTSpeed MaxNLOADIF1C MaxNLOADIF2C MaxNLOADIF3C MaxNLOADIF4C MaxNLOADIF5C MinRTC MaxNLOADRTC MaxNLOADIF1H MaxNLOADIF2H MaxNLOADIF3H MaxNLOADIF4H MaxNLOADIF5H MaxNLOADRTH MaxRTH MaxNLOADPSC MaxNLOADPSH Model dependent parameters - WNG (WNG) Wall Mounted Models Parameter name 25 35 50 60 72 80 NLOAD limits as a function of selected indoor fan speed MaxNLOADIF1C 40 40 45 50 53 68 MaxNLOADIF2C 53 53 62 85 75 90 MaxNLOADIF3C 120 120 120 120 105 120 MaxNLOADIF4C 127 127 127 127 127 127 MaxNLOADIF5C 127 127 127 127 127 127 Indoor Fan speeds IFVLOWC 700 700 700 800 850 850 IFLOWC 800 800 900 1000 1000 1000 IFMEDC 900 950 1050 1100 1150 1150 IFHIGHC 1050 1100 1200 1250 1350 1300 IFTURBOC 1150 1200 1250 1300 1400 1350 IFVLOWH 700 700 700 800 900 900 IFLOWH 800 850 900 950 1050 1050 IFMEDH 950 1000 1100 1150 1200 1200 IFHIGHH 1100 1150 1250 1250 1350 1300 IFTURBOH 1200 1250 1300 1300 1400 1350 12-16 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM Model dependent parameters - SX A (SX 18) B (SX 24) C (SX 30) Cap .Group 3 NomLoadC 68 NomLoadH 77 MaxNLOADIF1C 40 MaxNLOADIF2C 60 MaxNLOADIF3C 90 MaxNLOADIF4C 90 MaxNLOADIF5C 90 MinRTC 20 MaxNLOADRTC 127 MaxNLOADIF1H 127 MaxNLOADIF2H 127 MaxNLOADIF3H 127 MaxNLOADIF4H 127 MaxNLOADIF5H 127 MaxNLOADRTH 127 MaxRTH 27 MaxNLOADPSC 68 MaxNLOADPSH 77 4 60 60 127 127 127 127 127 20 127 127 127 127 127 127 127 27 60 60 4 63 67 127 127 127 127 127 20 127 127 127 127 127 127 127 27 63 67 Unit SM SX DCI 1-A.3 GB CONTENT 12-17 CONTROL SYSTEM 12.12.2 Outdoor Units SW Parameters: Model dependent parameters for DCI50/60 # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 12-18 Name MinFreqC MaxFreqC MinFreqH MaxFreqH NormAccel NormDecel Step1Freq Step2Freq Step3Freq OFVL OFLOWC OFMEDC OFMAXC OFLOWH OFMEDH OFMAXH OFANTESTMODEC OFANTESTMODEH OFDelTestMode CTTOH1 CTTOH2 CTTOH3 CTTOH4 CCROC1 CCROC2 CCROC3 CCROC4 DEICT1 DEICT2 DEICT3 ProtFreqLimit EEVDecierOpen OptimDeicFreq EEVMinOperOpenC EEVMaxOperOpenC EEVMinOperOpenH EEVMaxOperOpenH EEVNormRate EEVHighRate EEVMaxOpen OFLowFreqC OFMedFreqC OFLowFreqH OFMedFreqH HeaterDisableFlag DeiceFreqChRV OATRefC SUCT Enable HST Enable OAT Enable OATRefH MinTargCTTC MaxTargCTTC MinTargCTTH MaxTargCTTH DST DSTF OATLimitC OATLimit1H OATLimit2H MaxFreqAsOATC MaxFreqAsOAT1H MaxFreqAsOAT2H Single DCI-50 Single DCI 60 20 85 20 95 1 1 60 70 90 20 60 76 92 60 83 100 92 100 28 94 98 102 105 10 10.5 10.8 11.2 60 36 6 60 100 90 50 380 50 380 33 12 500 40 70 40 86 0 0 35 0 1 1 7 30 95 40 95 8 12 28 6 15 64 85 60 20 95 26 94 1 1 60 70 90 20 55 70 79 55 70 79 83 83 28 94 98 102 105 11.4 11.8 12.2 12.6 60 36 6 60 180 90 80 380 60 300 33 12 500 35 55 40 60 0 0 35 0 1 1 7 30 90 45 90 8 12 28 6 15 85 80 60 CONTENT SM SX DCI 1-A.3 GB CONTROL SYSTEM Model dependent parameters for DCI72Z No. Name Single DCI-72Z 1 MinFreqC 15 2 MaxFreqC 70 3 MinFreqH 15 4 MaxFreqH 90 7 Step1Freq 35 8 Step2Freq 55 9 Step3Freq 90 10 OFMinRPM 8 11 OFMaxRPM 90 12 NightRPM 65 13 OFNNoiseMaxRPM 78 14 CTTOH1 90 15 CTTOH2 95 16 CTTOH3 100 17 CTTOH4 105 18 CCROC1 12.5 19 CCROC2 13.3 20 CCROC3 14.1 21 CCROC4 14.9 22 ProtFreqLimit 60 23 EEVMinOperOpenC 50 24 EEVMaxOperOpenC 480 25 EEVMinOperOpenH 50 26 EEVMaxOperOpenH 480 27 HeaterDisableFlag 0 28 HST Enable 1 29 OATLimitC 24 30 OATLimit1H 6 31 OATLimit2H 15 32 MaxFreqAsOATC 60 33 MaxFreqAsOAT1H 85 34 MaxFreqAsOAT2H 75 35 NormAccel 1 36 NormDecel 1 SM SX DCI 1-A.3 GB CONTENT 12-19 CONTROL SYSTEM Model dependent parameters for DCI72/80 Compressor Parameters Value MinOFFTime 3 MinOnTime 3 MaxCTT1 90 MaxCTT2 90 MinSpeedAsCTT1 26 MinSpeedAsCTT2 26 MaxSpeedC 75 MaxSpeedH 95 Step1RPS 40 Step2RPS 60 Step3RPS 75 NormAcc (sec/RPS) 1 NormDec (sec/RPS) 1 Down1(Sec/RPS) 12 Down2 (Sec/RPS) 7 DeiceAcc (Sec/RPS) 0.2 DeiceDec (Sec/RPS) 0.5 EEV Parameters Value NormEEVRate 30 EEVCompOFFOpen 200 EEVCompOFFTime 60 EEVMaxOpen 500 EEVMinOperOpenC 60 EEVMaxOperOpenC 500 EEVMinOperOpenH 70 EEVMaxOperOpenH 500 EEVMinOperOpenHInIDU 60 EEVMaxOperOpenHInIDU 140 EEVIDUOFFOpen 130 EEVMoveSteps 20 EEVTConstC 30 EEVTConstH 30 BlncTimTrnsStC 1 BlncTimStdyStC 1 BlncTimTrnsStH 1 BlncTimStdyStH 1 CompOffTimToTrnsSt 20 12-20 CONTENT SM SX DCI 1-A.3 GB EXPLODED VIEWS AND SPARE PARTS LISTS 13. EXPLODED VIEWS AND SPARE PARTS LISTS 13.1 Indoor Unit: SX 9, 12 DCI SM SX DCI 1-A.3 GB CONTENT 13-1 EXPLODED VIEWS AND SPARE PARTS LISTS 13.2 Indoor Unit: SX 9, 12 DCI No Part No Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 307979 382334 452731900 373247 455000600 323425 293321 452987400 4520158 4521029 372341 373245 221555 307981 484001 4525333 373244 371257 370281 375209-01 375209-05 375209-16 375209-17 4521827 4521831 372338 372339 263034 436665 391508 234213 391725 4521070 438413 438082 452935900 311036 Back panel Base panel EPS Evap. Assy SX25/35 Fan frame Capacitor SX25/35 Motor support Centrifugal fan Transformer for SX25/35 Motor SX25/35 Spring clip Fan cover Left panel Filter Front panel Air inlet assy Motor connect wire for SX25/35 Right panel Vertical louver Air outlet AIRWELL Display panel WESPER Display panel ELECTRA Display panel JOHNSON Display panel GORENJEN Display panel FAGOR Display panel Horizontal louver front Horizontal louver back Swing motor Stop motor Connect wire Display Power cord without plug Power cord (European plug) Room sensor Coil sensor DCI STORM Storm panel 20 21 22 23 24 25 26 27 28 29 30 13-2 CONTENT Qty 1 1 1 1 1 1 2 1 1 2 2 1 2 1 1 1 1 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SM SX DCI 1-A.3 GB EXPLODED VIEWS AND SPARE PARTS LISTS 13.3 Indoor Unit: SX 18, 24, 30 DCI SM SX DCI 1-A.3 GB CONTENT 13-3 EXPLODED VIEWS AND SPARE PARTS LISTS 13.4 Indoor Unit: SX 18 DCI No Part No Description 1 307980 Back panel 1 2 382333 Base panel EPS 1 3 4527244 Evap. Assy SX18 1 4 373246 Fan frame 1 5 455000604 Capacitor SX18 1 6 453206900 Transformer 1 7 323422 Motor support 1 8 293322 Centrifugal fan 2 9 4520931 Motor Assy SX18,24 1 10 4521029 Spring clip 2 11 4525333 Motor connect wire 1 12 372340 Fan cover 2 13 373245 Left panel 1 14 221554 Filter 2 15 307982 Front panel 1 16 484002 Air inlet assy 1 17 373244 Right panel 1 18 371257 Vertical louver 12 19 370280 Air outlet 1 20 375209-16 ELECTRA 372336 Horizontal louver front 1 372337 Horizontal louver back 1 22 263034 Swing motor 1 23 436665 Step motor 1 24 391508 Connect wire 1 25 234213 Display 1 26 391726 Power cord 3x2.5 1 27 438082 Coil sensor 1 28 438413 Room sensor 1 29 452935900 DCI storm 1 30 311036 Storm panel 1 21 13-4 Display panel CONTENT Qty 1 SM SX DCI 1-A.3 GB EXPLODED VIEWS AND SPARE PARTS LISTS 13.5 Indoor Unit: SX 24, 30 DCI No. Part No. Description Qty 1 484002 Grille 1 2 221554 Air Filter 2 3 373244 Right panel 1 4 307982 Frame Asy 1 5 371071-72 Display panel 1 6 470680004 Evaporator Assy 1 7 370280 Air Outlet Assy 1 8 285032 Draining Hose 1 9 372336 Horizontal louver front 1 9 372337 Horizontal louver back 1 10 371255 Vert. Louver 12 11 372340 Fan cover 1 12 293322 Fan 1 13 307980 Back panel 1 14 466236 Installation Plate 1 15 382333 Base panel EPS 1 16 466100005 Motor 1 17 323422 Motor support 1 18 436665 Step Motor 1 18 263034 Swing motor 1 20 455000603 Capacitor 1 21 234213 Display 1 22 373246 Fan frame 1 23 452935900 DCI storm 1 24 438082 Thermistor indoor coil 1 25 438413 Thermistor 1 26 311036 Storm panel 1 27 391508 DConnect wire 1 29 436609R Remote control 1 30 373245 Left panel 1 33 4521029 Spring clip 1 SM SX DCI 1-A.3 GB CONTENT 13-5 EXPLODED VIEWS AND SPARE PARTS LISTS 20 21 22 23 24 25 26 27 29 28 30 40 13-6 42 41 38 37 36 35 1 2 3 4 34 5 6 7 8 9 33 32 39 Outdoor Unit: GC 9, 12 DCI 31 13.6 CONTENT SM SX DCI 1-A.3 GB EXPLODED VIEWS AND SPARE PARTS LISTS 13.7 Outdoor Unit: GC 9, 12 DCI No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Part No. 433218 4526340 433223 4526476 4527092 433215 4523060 4526299 4526403 4524177 4524176 4526224 4526396 4526223 4526968 4526222 4526300 4526220 4526219 204107 4519188 433229 4522509 4526367 4526393 4518952 4518951 4526221 4526204 4526775 4526774 4526776 4526969 4526828 4526827 4519606 433228 4526368 4526298 4519614 4526480 4519300 433225 4519607 SM SX DCI 1-A.3 GB Description Front panel A Air inlet ring-420 Painting insulation plate Axial fan OD=401 DC motor for DCI25/35 Motor support Base painting Assy. Partition Outdoor DC inverter controller (English) Gas valve (R410A) Liquid valve(R410A) EMI fliter board 901-098-00 Chock Assy. 167-021-01 AC-IN connected wire Earthing wire for DCI Fuse connecting wire Therminal sheet Fuse stand JEF-511B(EHK P/N:150-038-00) Fuse 65TS(15A,230)150-031-00 Cable clip nylon 4 poles terminal block Value cover 4-Way valve coil 4-way valve welding Assy. (DCI25) 4-way valve welding Assy. (DCI35) 4-way valve (DCI25) 4-way valve (DCI35) Compressor wire DC Inverter compressor Assy. 5RS102XAB Compressor top thermistor(CTT) Outside air thermistor(OAT) Outside coil thermistor(OCT) Suction coil thermistor(SUCT) EEV Coil (CAN-MD 12FKS-1 White) Electronic expansion value (CAMB20YGFKS-1) Right side panel Back side net Condenser soldering assy Bridge Painting top cover Gasket for axial fan Nut M5 L Handle Left side panel painting plate CONTENT Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 13-7 EXPLODED VIEWS AND SPARE PARTS LISTS 13.8 13-8 Outdoor Unit: GC 18 DCI CONTENT SM SX DCI 1-A.3 GB EXPLODED VIEWS AND SPARE PARTS LISTS 13.9 Outdoor Unit: GC 18 DCI No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Part No. 433218 4526340 433223 4526476 4526475 4526457 4527363 4526459 4526203 4524595 4524176 4526224 4526396 4526223 4526968 4526222 4526300 4526220 4526533 204107 4519188 433229 4522509 4527327 4518952 4526221 4523446 4526775 4526774 4526776 4526969 4526215 4526216 4519606 433228 4526459 4526298 4519614 4526480 4519300 433225 4519607 SM SX DCI 1-A.3 GB Description Front panel A Air inlet ring-420 Painting insulation plate Axial fan OD=401 DC motor for DCI 50 Motor support Base painting Assy. Partition Outdoor DC inverter controller (English) Gas valve (R410A) Liquid valve(R410A) EMI fliter board 901-098-00 Chock Assy. 167-021-01 AC-IN connected wire Earthing wire for DCI Fuse connecting wire Therminal sheet Fuse stand JEF-511B(EHK P/N:150-038-00) Fuse 65TS(20A,230)150-031-00 Cable clip nylon 4 poles terminal block Value cover 4-Way valve coil 4-way valve welding Assy. 4-way valve Compressor wire DC Inverter compressor Assy. 5CS130XCC03 Compressor top thermistor(CTT) Outside air thermistor(OAT) Outside coil thermistor(OCT) Suction coil thermistor(SUCT) Electronic expansion valve ZDPF(L)-1.6C-01-RK for R410A EEV COIL QA(L)12-HR-01A-RK Right side panel Back side net Condenser soldering assy Bridge Painting top cover Gasket for axial fan Nut M5 L Handle Left side panel painting plate CONTENT Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 13-9 EXPLODED VIEWS AND SPARE PARTS LISTS 13.10 13-10 Outdoor Unit: GC 24, 30 DCI CONTENT SM SX DCI 1-A.3 GB EXPLODED VIEWS AND SPARE PARTS LISTS 13.11 Outdoor Unit: GC 24, 30 DCI No. Part No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 465100000 4523652 4523758 452960400 461600002 452956700 4526522 452855600 4522601 4523653 452966200 452956500 452677601 452809900 452803300 452783600 452783200 453256100 4526080 4526513 4526514 4523654 4522602 4518950 467300005 204107 467420003 453138800 4526215 4526216 462300002 453175500 453083800 453256000 452809700 453170000 452888500 464250004 4526968 4526774 4523657 4522600 SM SX DCI 1-A.3 GB Description Outlet grid PAINTED LEFT CABINET ASSY Nut M8 left OUTDOOR FAN 4-Way Valve Assy. 4-way valve coil Four-Way Valve R410A DC Resin Motor(EHD80A90EC/SIC-71FW-F170-1) Right Handle Painted Right Cabinet Assy. Compressor Top Thermistor(CTT) Suction Thermistor(SUCT) Outdoor Coil Thermistor(OCT) Base Plate Painting Assy. Compressor Assy. TNB220FLBM1 Oil Separator Assy. Liquid-Gas Separator Support Painting Assy./Gas-Liquid Separator Valve Plate Paint Assy. Low Press Valve R410A High Press Valve R410A Painted Right Back Cabinet Assy. Valve Cover Filter Drier BFK-053S Display Assy.(optional) Cable clip Nylon 7 Poles Terminal Block Terminal Plate Electronic Expansion Valve ZDPF(L)-1.6C-01-RK EEV COIL QA(L)12-MD-02 Condenser Assy. Guard Net Painting Assy. OAT Support Choke Assy. Partition Plate Controller Motor Support Controller Connect Plate Grounding wire with magnetic ring Outdoor Air Thermistor(OAT) Painted Top Cover Assy. Left Handle CONTENT Unit 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 13-11 APPENDIX A APPENDIX A INSTALLATION AND OPERATION MANUAL ► OPERATION MANUAL SX 9, 12, 18, 24, 30 DCI ► INSTALLATION MANUAL SX 9, 12, 18, 24, 30 DCI SM SX DCI 1-A.3 GB CONTENT 14-1 ">
Advertisement
Key Features
- High COP for energy efficiency
- Low indoor and outdoor noise levels
- Microprocessor control for precise temperature control
- Infrared remote control with LED for easy operation
- Automatic treated air sweep for even cooling or heating
- Fresh Air & Distribution treated air to adjacent room
- Indoor centrifugal fan for powerful airflow
- Easy installation and service
Frequently Answers and Questions
What type of refrigerant does the Airwell GC 30 DCI use?
The Airwell GC 30 DCI uses R410A refrigerant.
What is the COP of the Airwell GC 30 DCI?
The COP of the Airwell GC 30 DCI is high, which means it is very energy efficient.
How many indoor units can be connected to the Airwell GC 30 DCI?
The Airwell GC 30 DCI can be connected to multiple indoor units, depending on the model of the indoor units.
What is the warranty on the Airwell GC 30 DCI?
The warranty on the Airwell GC 30 DCI varies depending on the country of purchase.