Agilent Technologies | U1231A | Specifications | Agilent Technologies U1231A Specifications

Agilent Handheld Tools
For Electronic, Electrical and
Industrial Process Testing
• Digital multimeters
• Digital oscilloscopes
• Clamp meters
• LCR meters
• Multifunction calibrator meter • Capacitance meters
Digital Multimeters
From electronics troubleshooting to installation and maintenance of machinery, Agilent handheld digital multimeters are designed to withstand
the harsh working conditions and improve safety. Each DMM is compatible with the U1177A Infrared (IR)-to-Bluetooth® adapter which offers
wireless remote connectivity solution. Our range of handheld DMMs are also equipped with smart features to help you quickly detect problems
and obtain accurate measurements.
Recommended
for
Model no.
Installation and
maintenance
of machinery,
electrical systems
Electrical, HVAC
and utilities
Electronics troubleshooting
Industrial
U1231A
U1232A
U1233A
U1241B
U1242B
U1251B
U1252B
U1253B
U1271A
U1272A
U1273A
U1273AX
Display
resolution
(counts)
6,000
6,000
6,000
10,000
10,000
50,000
50,000
50,000
30,000
30,000
30,000
30,000
Dual display
N/A
N/A
N/A
N/A
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Analog
bar-graph
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Back-light
Yes
Yes
Yes
Yes
Yes
OLED display
Yes
Yes
AC
bandwidth
1 kHz
1 kHz
1 kHz
2 kHz
2 kHz
30 kHz
100 kHz
100 kHz
20 kHz
100 kHz
100 kHz
100 kHz
True RMS
AC
AC
AC
AC
AC
AC
AC + DC
AC + DC
AC
AC + DC
AC + DC
AC + DC
Auto/manual
ranging
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
600 mV to
600 V
600 Ω to
60 MΩ
99.99 Hz
to
99.99 kHz
1000 nF to
10 mF
600 mV to
600 V
60 µA to
10 A
600 Ω to
60 MΩ
99.99 Hz
to
99.99 kHz
1000 nF to
10 mF
600 mV to
600 V
60 µA to
10 A
600 Ω to
60 MΩ
99.99 Hz
to
99.99 kHz
1000 nF to
10 mF
1 V to
1000 V
1 mA to
10 A
1 kΩ to
100 MΩ
100 Hz
to
1000 kHz
1 uF to
10 mF
Temperature:
Type, range
N/A
N/A
K: –40 to
1372 °C
K: –40 to
1000 °C
1 V to
1000 V
1 mA to
10 A
1 kΩ to
100 MΩ
100 Hz
to
1000 kHz
1 uF to
10 mF
K: –40 to
1000 °C
J: –40 to
1000 °C
Continuity with
beeper
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Diode test
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Display
Yes
Yes
(two intensity (two intensity
levels)
levels)
OLED display OLED display
Basic features
Measurements
Voltage
AC/DC: Range
Current
AC/DC: Range
Resistance:
Range
Frequency:
Range
Capacitance:
Range
N/A
50 mV to
50 mV to
50 mV to 300 mV to 30 mV to
1000 V
1000 V
1000 V
1000 V
1000 V
500 µA to 500 µA to 500 µA to 300 µA to 300 µA to
10 A
10 A
10 A
10 A
10 A
500 Ω to
500 Ω to
500 Ω to
300 Ω to 30 Ω to 300
500 MΩ
500 MΩ
500 MΩ
100 MΩ
MΩ
99.999 Hz 99.999 Hz 99.999 Hz 99.999 Hz 99.999 Hz
to
to
to
to
to
999.99 kHz 999.99 kHz 999.99 kHz 999.99 kHz 999.99 kHz
10 nF to
10 nF to
10 nF to
10 nF to
10 nF to
100 mF
100 mF
100 mF
10 mF
10 mF
K: –200 to K: –200 to
K: –200 to
K: –200 to
1372 °C
1372 °C
K: –200 to
1372 °C
1372 °C
J: –210 to J: –210 to
1372 °C
J: –210 to
1200 °C
1200 °C
1200 °C
30 mV to
30 mV to
1000 V
1000 V
300 µA to 300 µA to
10 A
10 A
30 Ω to
30 Ω to
300 MΩ
300 MΩ
99.999 Hz 99.999 Hz
to
to
999.99 kHz 999.99 kHz
10 nF to
10 nF to
10 mF
10 mF
K: –200 to K: –200 to
1372 °C
1372 °C
J: –210 to J: –210 to
1200 °C
1200 °C
Data management
Min/max
recording
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Display hold
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Peak hold
Yes
Yes
Yes
N/A
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Manual
datalogging
N/A
N/A
N/A
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Null
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
IR-USB/
Bluetooth
N/A
N/A
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Connectivity
% scale of
4-20 mA
2
Digital Multimeters Continued
Model no.
Installation and
maintenance
of machinery,
electrical systems
Electrical, HVAC
and utilities
Recommended
for
U1242B
Electronics troubleshooting
U1251B
U1252B
U1253B
Industrial
U1231A
U1232A
U1233A
U1241B
U1271A
U1272A
U1273A
U1273AX
–10 to
55 °C, 0%
to 80% RH
2000 m
–10 to
55 °C, 0%
to 80% RH
2000 m
–10 to
55 °C, 0%
to 80% RH
2000 m
Measurement
category
CAT III
600 V
CAT III
600 V
CAT III
600 V
–10 to
–10 to
–20 to
–20 to
–20 to
–20 to
–20 to
55 °C, 0 to 55 °C, 0 to 55 °C, 0 to 55 °C, 0 to 55 °C, 0 to 55 °C, 0 to 55 °C, 0 to
80% RH
80% RH
80% RH
80% RH
80% RH
80% RH
80% RH
2000 m
2000 m
2000 m
2000 m
2000 m
3000 m
3000 m
CAT III
CAT III
CAT III 1000 CAT III 1000 CAT III 1000 CAT III 1000 CAT III 1000
1000 V/
1000 V/
V/CAT IV
V/ CAT IV V/ CAT IV
V/CAT IV
V/CAT IV
CAT IV
CAT IV
600 V
600 V
600 V
600 V
600 V
600 V
600 V
–20 to
55 °C, 0 to
80% RH
3000 m
CAT III
1000 V/
CAT IV
600 V
–40 to
55 °C, 0 to
80% RH
3000 m
CAT III
1000 V/
CAT IV
600 V
Battery type
(included)
4 x AAA
alkaline
4 x AAA
alkaline
4 x AAA
alkaline
4 x AAA
alkaline
4 x AAA
alkaline
9V
7.2 V
(rechargeable)
4 x AAA
alkaline
4 x AAA
lithium
Battery life
500 hours
500 hours
500 hours
300 hours
300 hours
72 hours
Dimensions
(H x W x D)
169.0 x
86.0 x
52.0 mm
169.0 x
86.0 x
52.0 mm
169.0 x
86.0 x
52.0 mm
193.8 x
92.2 x
58.0 mm
193.8 x
92.2 x
58.0 mm
203.5 x
94.4 x
59.0 mm
Built-in
flashlight,
continuity
alert with
flashing
backlight,
ZLow
Built-in
flashlight,
Built-in
non-contact
flashlight,
voltage
continuity
detector
alert with with Vsense,
flashing
continuity
backlight,
alert with
ZLow
flashing
backlight,
ZLow
N/A
20 MHz
frequency
counter, programmable
square wave
generator
General
Operating
temperature
Altitude
Advanced
functions
Switch
counter
Switch
counter, harmonic ratio,
dual and
differential
temperature
mesurements
7.2 V
(rechargeable)
4 x AAA
alkaline
36 hours
8 hours
300 hours
203.5 x
94.4 x
59.0 mm
203.5 x
94.4 x
59.0 mm
207.0 x
92.0 x
59.0 mm
4 x AAA
alkaline
300 hours 30-60 hours 50-100 hours
207.0 x
92.0 x
59.0 mm
207.0 x
92.0 x
59.0 mm
Organic
LED display,
Low pass
Low pass
Low pass
Low pass
20 MHz
filter, low
filter, low
filter, low
filter, AC
frequency
impedance impedance impedance
and/or DC
counter, promode, offset mode, offset mode, offset
voltage
grammable
compensa- compensa- compensacheck
square wave
tion
tion
tion
generator
U1177A Infrared (IR)-to-Bluetooth Adapter
Monitoring multiple measurements simultaneously and wirelessly is now made possible
with the U1177A Infrared (IR)-to-Bluetooth adapter. To achieve this, simply install the free
software on your Android smart phone or tablet, and connect it to any Agilent
handheld digital multimeter (HH DMM) that is attached to a U1177A. With this, you
not only get real-time measurement monitoring and data logging, both apply to Android
devices and PCs as well.
Features
• Compatible with Agilent U1210 series handheld clamp meters
and other handheld digital multimeters such as the U1230
series, U1240 series, U1250 series and U1270 series.
• Monitor up to 3 multimeter measurements at the same time
with Agilent Mobile Meter software
• Perform data logging with Agilent Mobile Logger software
Agilent U1177A
Infrared (IR)-to-Bluetooth adapter
Web link
www.agilent.com/find/U1177A
Bluetooth and the Bluetooth logo are registered trademarks owned by
Bluetooth SIG, Inc., U.S.A. and licensed to Agilent Technologies, Inc.
Agilent wireless remote connectivity solution
3
207.0 x
92.0 x
59.0 mm
Clamp Meters
Our clamp meters are designed to address the toughest electrical challenges without compromising on safety. Certified with safety ratings
and equipped with a wealth of features – you are now ready to make measurements with more confidence.
Recommended for
Installation and maintenance of power
distribution and supplies
Commercial or residential electrical
installation and maintenance
U1211A
U1212A
U1213A
U1191A
U1192A
U1193A
U1194A
4,000
4,000
4,000
6,000
6,000
6,000
6,000
Yes
Yes
Yes
No
No
No
No
Analog bar-graph
Yes
Yes
Yes
No
No
No
No
Back-light
Yes
Yes
Yes
Yes
Yes
Yes
Yes
AC bandwidth
400 Hz
400 Hz
2 kHz
500 Hz
500 Hz
500 Hz
500 Hz
RMS Method
True RMS AC
AC
AC + DC
Average
responding
Average
responding
True RMS
True RMS
Yes
Yes
Yes
400 to 1000 V
400 to 1000 V
4 V to 1000 V
Model no.
Display
Display resolution (counts)
Dual display
Basic features
Auto/manual ranging
Auto ranging only Auto ranging only Auto ranging only Auto ranging only
Measurements
Voltage AC/DC: Range
Current AC/DC: Range
ACI: 40 to 1000 A
600 V
40 to
1000 A
40 to
1000 A
ACI: 400 A
60 to 600 V
60 to 600 V
ACI: 60 to
400 A
ACI: 60 to
600 A
60 to 600 V
ACI: 60 µA to
600 A
DCI: 60 µA to
600 A
Resistance: Range
400 Ω to 4 kΩ
400 Ω to 4 kΩ
400 Ω to 40 MΩ
600 Ω to 6 kΩ
600 Ω to 60 kΩ
600 Ω to 60 kΩ
600 Ω to 60 kΩ
Frequency: Range
99.99 Hz to
999.9 kHz
99.99 Hz to
999.9 kHz
99.99 Hz to
999.9 kHz
N/A
99.99 Hz to
99.99 kHz
99.99 Hz to
99.99 kHz
99.99 Hz to
99.99 kHz
400 to 4000 μF
400 to 4000 µF
4 to 4000 µF
N/A
600 μF to 6 mF
600 μF to 6 mF
600 μF to 6 mF
Temperature: Type, range
N/A
K: –200 to
1372 °C
K: –200 to
1372 °C
N/A
N/A
N/A
K-type: –40 to
1200 °C
Continuity with beeper
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Diode test
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Min/max recording
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Display hold
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Peak hold
Yes
Yes
Yes
N/A
N/A
N/A
N/A
Capacitance: Range
Data management
Null
Connectivity
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Bluetooth
Bluetooth
Bluetooth
N/A
N/A
N/A
N/A
–10 to 50 °C,
0 to 80% RH
CAT III 1000 V /
CAT IV 600 V
–10 to 50 °C,
0 to 80% RH
CAT III 1000 V /
CAT IV 600 V
–10 to 50 °C,
0 to 80% RH
CAT III 1000 V /
CAT IV 600 V
–10 to 50 °C,
0 to 80% RH
CAT III 600 V /
CAT IV 300 V
–10 to 50 °C,
0 to 80% RH
CAT III 600 V /
CAT IV 300 V
–10 to 50 °C,
0 to 80% RH
CAT III 600 V /
CAT IV 300 V
–10 to 50 °C,
0 to 80% RH
CAT III 600 V /
CAT IV 300 V
General
Operating temperature
Measurement category
Battery type (included)
9V
9V
9V
1.5 V
1.5 V
1.5 V
1.5 V
Battery life
60 hours
60 hours
60 hours
200 hours
200 hours
200 hours
200 hours
Dimensions (H x W x D)
273.0 x
106.0 x
43.0 mm
273.0 x
106.0 x
43.0 mm
273.0 x
106.0 x
43.0 mm
225.0 x
77.1 x
38.6 mm
225.0 x
77.1 x
38.6 mm
238.0 x
77.1 x
38.6 mm
238.0 x
77.1 x
38.6 mm
52 mm / 2 "
52 mm / 2 "
52 mm / 2 "
31 mm
31 mm
37 mm
37 mm
Wire separator,
Auto power off
Wire separator,
built-in flashlight,
Vsense,
Auto power off
Wire separator,
built-in flashlight,
Vsense,
Auto power off
Wire separator,
built-in flashlight,
Vsense,
Auto power off
Clamp opening
Advanced functions
Auto power off
Auto power off
Auto power off
4
Oscilloscopes
Our handheld scopes are designed to be used across a wide range of applications and troubleshooting tasks. Each model come with
different specifications to tailor to your needs, and are safety certified for safer measurements.
Model No.
U1602B
U1604B
U1610A
20 MHz
40 MHz
5 mV/div to 20 mV/div: ± 5% full scale
50 mV/div to 100 V/div: ± 3% full scale
100 MHz
U1620A
Vertical System: Scope Channels
Bandwidth (-3 dB)
DC vertical gain accuracy
200 MHz
±2% of full scale
Full scale is equivalent to 8 div
Acquisition: Scope Channels
Maximum sample rate
Single Channel Operation
Dual Channel Operation
Vertical resolution
Maximum recording length
Single Channel Operation
Dual Channel Operation
200 MSa/s interleave
100 MSa/s each channel
8-bits
1 GSa/s interleave
2 GSa/s interleave
500 MSa/s each channel
1 GSa/s each channel
8-bits
125 Kpts
125 Kpts
120 Kpts interleave
60 Kpts each channel
2 Mpts interleave
1 Mpts each channel
<17.5 ns
<8.8 ns
3.50 ns typical
1.75 ns typical
Vertical System: Scope Channels
Rise time
Maximum input
Bandwith limit
Channel-to-channel isolation
Probe attentuation factors
CAT III 300 Vrms (up to 400 Hz) from terminal
to ground
N/A
N/A
1x, 10x, 100x
CAT III 600 V (with 10:1 probe)
CAT III 300 V (direct)
10 KHz and 20 MHz (selectable)
Yes, CAT III 600 V
1x, 10x, 100x
50 ns to 50 s/div
10 ns to 50 s/div
Main, XY, roll
5 ns/div to 50 s/div
2 ns/div to 50 s/div
Main, zoom, XY, roll
Channel 1 and Channel 2
Auto, normal, single
Edge, Pattern, Pulse Width, Video
Peak-to-peak, maximum, minimum, amplitude, top,
base, +overshoot, –overshoot, preshoot, RMS, mean
and one cycle mean, Frequency, period, +width, –
width, and +duty cycle and –duty cycle on any channel.
Rise time, fall time, delay and phase shift
Channel 1, Channel 2, External
Normal, Single, Auto
Edge, Glitch, TV, Nth Edge, CAN, LIN
Delay, duty cycle (+/–), fall/rise time, frequency, period,
phase shift, T-max,
T-min, width (+/–), amplitude, average, base, crest, cycle
mean, maximum,
minimum, overshoot, peak-to-peak, preshoot, standard
deviation, top,
Vrms (AC/DC), active/apparent/reactive power, power
factor
CH1 + CH2, CH1 – CH2, CH2 – CH1, CH1 × CH2, CH1/
CH2, CH2/CH1, d/dt (CH1),
d/dt (CH2), ∫(CH1)dt, ∫(CH2)dt, FFT
Horizontal System
Range
Modes
Trigger system
Sources
Modes
Types
Auto measurements
Waveform math functions
CH1 + CH2, CH1 – CH2, CH2 – CH1
Digital Multimeter measurement
Voltage AC/DC range
Resistance range
Capacitance range
Diode range
Temperature range
Frequency
AC Current range
600 mV to 600 V
600 Ω to 60 MΩ
60 nF to 300 uF
1V
600 °C
N/A
60 A
1000 mV to 1000 V
1000 Ω to 100 MΩ
1000 nF to 10 mF
1V
–50 to 1000 °C
100 Hz to 1000 KHz
N/A
6,000 counts
Beeper < 60 W in 600 W range
Yes
10,000 counts
Continuous beep when resistance <10 Ω
Yes
Measurement characteristic
Resolution
Continuity
Datalogger
5
Oscilloscopes Continued
Model No.
U1602B
U1604B
U1610A
U1620A
General
Display
Resolution
IP rating
4.5" diagonal color
5.7" VGA TFT Color LCD (sunlight viewable)
320 x 240 pixels
640 x 480 pixels
N/A
IP41
Save/Recall
Up to 10 setups and traces
10 setups and waveforms can be saved and recalled internally
Battery type
Ni-MH rechargeable battery pack 7.2 V
Li-Ion rechargeable battery pack, 10.8 V
Battery life
I/O
Dimension (H x W x D)
Weight
UI language
Advanced functions
4 hours
3 hours
USB 2.0 full speed client
USB 2.0 full speed host/client port
241 x 138 x 66 mm
183 x 270 x 65 mm
1.5 kg
<2.5 kg
10 selectable languages
10 selectable languages
CSTN LCD screen
3 viewing modes (indoor, outdoor, night-vision),
VGA TFT LCD screen, dual windows zoom
U1230 Series – Handheld Digital Multimeters
Whether it is dark, noisy or even dangerous, the U1230 Series Handheld digital
multimeter keeps you equipped with features that anticipate worst-case scenarios.
The ergonomic shaped handheld allows you to single-handedly illuminate the test
area with a built-in flashlight while selecting measurement functions using the
rotary dial. Vsense performs non-contact voltage detection while continuity
detection is made easy with the audible beeper alert and flashing backlight
display. With the U1230 Series, you work better in the conditions you are in.
Features
•
•
•
•
•
•
Built-in LED flashlight to illuminate test area
Flashing backlight as additional visual alert during continuity tests in noisy areas
Vsense performs non-contact voltage detection
Data logging capability (stores up to 10 readings)
IR-to-USB connectivity to transfer data to PC for record
Bluetooth wireless connectivity (optional U1177A Infrared (IR)-to-Bluetooth Adapter required)
Applications with U1230 Series Handheld Digital Multimeters
In an electrical or industrial work setting,
making measurements during power
failures or in a poorly lit environment can be
a common occurrence.
Working in a dark environment can be
cumbersome; you may need to carry
multiple test tools- and a flashlight. This
is why the U1230 Series is well-designed
with a set of features that enable electricians to work better in these environments.
The U1230 Series now comes with a
built-in flashlight, allowing electricians to
single-handedly illuminate the test area
while troubleshooting circuits in cramped
or dark areas. The flashlight is also easily
activated with a one push button, allowing
measurements and troubleshooting tasks to
be performed more efficiently.
The U1230 Series also performs continuity
test with a unique combination of beeper
alert and flashing backlight display. The
flashing backlight display serves as an
additional visual alert to the electrician,
when performing measurement in a noisy or
dim place. Both of these alerts occur simultaneously making them hard-to-miss, thus
6
allowing continuity tests to be
performed quicker and easier.
Performing electrical measurements in
a poorly lit or noisy environment can be
potentially hazardous. The U1233A handheld digital multimeter comes with Vsense
which performs non-contact
detection of live voltages. With Vsense,
electricians can now perform their tasks
more safely by avoiding hot or live voltages.
Upon the detection of live voltages, it
simultaneously produces a unique combination of two alerts; audible beep alert and
blinking LED light.
Specifications of the U1230 Series Digital Multimeters
U1231A
U1232A
U1233A
6,000
Yes
Yes
Yes
45 Hz to 1 kHz
Yes
6,000
Yes
Yes
Yes
45 Hz to 1 kHz
Yes
6,000
Yes
Yes
Yes
45 Hz to 1 kHz
Yes
600 mV to 600 V
0.5% + 2 cnts
600 mV to 600 V
1.0% + 3 cnts
45 Hz to 1 kHz
600 mV to 600 V
0.5% + 2 cnts
600 mV to 600 V
1.0% + 3 cnts
45 Hz to 1 kHz
60 µA to 10 A
1.0% + 2 cnts
600 mV to 600 V
0.5% + 2 cnts
600 mV to 600 V
1.0% + 3 cnts
45 Hz to 1 kHz
60 µA to 10 A
1.0% + 2 cnts
N/A
60 µA to 10 A
1.5% + 3 cnts
45 to 500 Hz
60 µA to 10 A
1.5% + 3 cnts
45 to 500 Hz
600 Ω to 60 MΩ
0.9% + 3 cnts
600 Ω to 60 MΩ
0.9% + 3 cnts
600 Ω to 60 MΩ
0.9% + 3 cnts
99.99 Hz to 99.99 kHz
0.1% + 2 cnts
99.99 Hz to 99.99 kHz
0.1% + 2 cnts
99.99 Hz to 99.99 kHz
0.1% + 2 cnts
1000 nF to 10 mF
1.9% + 2 cnts
1000 nF to 10 mF
1.9% + 2 cnts
1000 nF to 10 mF
1.9% + 2 cnts
N/A
N/A
–40 to 1372 °C
1% + 1 °C
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
IR-USB/Bluetooth
N/A
Yes
Yes
Yes
N/A
Yes
IR-USB/Bluetooth
N/A
Yes
Yes
Yes
N/A
Yes
IR-USB/Bluetooth
N/A
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
Yes
Yes
Yes
IP 42
CAT III 600 V
IP 42
CAT III 600 V
IP 42
CAT III 600 V
Yes
Yes
Yes
Yes
Yes
Yes
Basic features
Display resolution
Auto/manual ranging
Analog bar graph
Backlight
AC bandwidth
True RMS
Measurements
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Frequency
Capacitance
Temperature
Range
Accuracy
Range
Accuracy
Bandwidth
Range
Accuracy
Range
Accuracy
Bandwidth
Range
Accuracy
Range
Accuracy
Range
Accuracy
Range
Accuracy
Diode test
N/A
Data management
Min/max recording
Trigger hold
Auto hold
Manual datalogging
Null
Connectivity
% scale of 4-20 mA
Special features
Built-in flashlight
Beep + backlight alert for continuity
Vsense for non-contact voltage
detection
ZLOW- low impedance mode
Safety and regulatory
IP rating
Over-voltage safety protection
EN/IEC 610101-1:2001
compliance
CSA C22.2 No. 61010-1:2004
compliance
represents key specifications/feature
7
Specifications of the U1230 Series Digital Multimeters Continued
U1231A
U1232A
U1233A
–10 to 55 °C, 0% to 80% RH
4 x 1.5 V Alkaline battery
500 hours
3 years
169 × 86 × 52 mm
–10 to 55 °C, 0% to 80% RH
4 x 1.5 V Alkaline battery
500 hours
3 years
169 × 86 × 52 mm
–10 to 55 °C, 0% to 80% RH
4 x 1.5 V Alkaline battery
500 hours
3 years
169 × 86 × 52 mm
General
Operating temperature
Battery (included)
Battery life
Warranty
Dimensions (H x W x D)
Web link
www.agilent.com/find/U1230DMM
For complete specifications, please refer to data sheet 5990-7550EN
How to?
Select a Handheld DMM that is Right for You
http://cp.literature.agilent.com/litweb/pdf/5990-5197EN.pdf
Think Safety When Selecting a Handheld Multimeter
http://cp.literature.agilent.com/litweb/pdf/5990-4578EN.pdf
U1240 Series - Handheld Digital Multimeters
Installation and maintenance of machinery, electrical systems and more often
require numerous quick checks and fixes, sometimes under hazardous conditions.
Whether you need to quickly inspect power supplies for harmonics, detect glitches
in switch systems or monitor differential temperature, the U1240 Series of handheld
digital multimeters (DMMs) is up to the task. With all you need in one portable
instrument, you can travel light and finish the day’s work with ease. Plus, you’ll be
glad to know it’s easy to own one, even with the DMM’s rich capabilities.
Features
•
•
•
•
•
•
Low micro-amp and high Mega-ohm ranges
Switch/Relay counter for glitch detection
Harmonic ratio measurement in AC supplies
Dual and differential temperature measurements
Data logging to instrument on the go
Bluetooth® wireless connectivity
(optional U1177A Infrared (IR)-to-Bluetooth Adapter required)
Applications with U1240 Series Handheld Digital Multimeters
Harmonic ratio measurement for maintenance of facilities, motors, generators
and transformers
Fundamental
Any periodic waveform other than an
absolutely pure sine wave has some
amount of harmonic content. If these
unwanted multiples of the fundamental
frequency become too large, they have
unwanted side effects: overheating
that shortens the lifespan of motors,
generators and transformers; premature
tripping of circuit breakers; and blown fuses.
Resultant waveform
rd
th
3 Harmonic
5 Harmonic
When harmonics are present, the shape of an original sinusoidal
waveform becomes distorted, producing a non-zero harmonic ratio.
8
Regular maintenance with an accurate,
dependable DMM ensures early detection of harmonics in the AC supply. One of
the quickest ways to detect and gauge the
percentage of distortion due to harmonics
is to measure the harmonic ratio of the
incoming AC voltage.
Harmonic ratio
The U1240 Series offers a fast one-button
check with its harmonic ratio function.
The ratio percentage helps you decide if
further analysis of the power source is
necessary with an oscilloscope or a
spectrum analyzer.
Vrms
–
Vavg
Vrms
Vrms
Measuring circuit
x 100%
Vavg
RMS-calculating
converter calculates Multiplies rectified
average by 1.1
heating value
Response to
sine wave
Correct
Correct
Response to
square wave
Correct
10% high
Response to
distorted wave
Correct
Up to 50% low
Switch counter for detection of glitches on switch and relay systems
Careful maintenance of the switches
and relays used in facilities and
machinery helps ensure that they’re
operating as expected in their OPEN or
CLOSED settings. You can check their
performance with just one button using
the U1240 Series’ switch counter function.
This function detects intermittent OPEN or
CLOSED occurrences across relay/switch
contacts in the reversed setting. The total
count indicates the extent of relay/switch
faults and determines if further troubleshooting is necessary.
9
Dual and differential temperature for efficient testing of HVAC systems
Whether you’re installing, maintaining or
troubleshooting heating, ventilation and
air-conditioning (HVAC) systems in cars,
offices, factories, stores or homes,
temperature measurements are crucial.
For example, to ensure boiler temperature
meets safety requirements, you’d have to
measure boiler and air temperature
simultaneously to get accurate real-time
readings. With a faulty air conditioning
system, viewing the temperature difference between warm return air and cool
supply air helps reveal the cooling behavior
of the evaporator with respect to time.
With the U1240 Series, you need just one
instrument for convenient, efficient dual
and differential temperature measurements.
Compressor
Solar collector
Condenser
Condenser fan
Warm air out
Ambient (outside) air in
To taps
Controller
Tank
Pump
Warm return air in
Cool supply
air out
Boiler
Evaporator blower
Evaporator
Cold water feed
Metering
device
Expansion valve
Air-conditioning system
Solar heating system
Specifications of the U1240 Series Digital Multimeters
U1241B
U1242B
10,000
Yes
Dual-intensity
10,000
Yes
Dual-intensity
AC
0.09%
Yes
AC
0.09%
Yes
1000 V
10 A (down to microamps)
100 MΩ
200 kHz
0.1 nF to 10 mF
1000 °C, K-type thermocouple
Yes
Yes
Yes
N/A
Yes
1000 V
10 A (down to microamps)
100 MΩ
200 kHz
0.1 nF to 10 mF
1000 °C, K-type thermocouple, T1/T2/T1-T2
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
N/A
Yes
Yes
Yes
IR-USB/Bluetooth
100 manual, 200 interval points
Display
Counts
Analog bar graph
Backlight
Back features
True RMS
Basic DCV accuracy
Auto/manual ranging
Measurements
Voltage AC/DC
Current AC/DC
Resistance
Frequency
Capacitance
Temperature
Continuity with beeper
Diode test
4-20 mA % scale
Harmonic ratio
Switch counter
Data management
Min/Max/Avg recording
Data hold
Null
Connectivity
Data logging
represents key specifications/features
10
Specifications of the U1240 Series Digital Multimeters Continued
U1241B
U1242B
CAT III 1000 V/CAT IV 600 V
CAT III 1000 V/CAT IV 600 V
Yes
Yes
Yes
Yes
–10 to 55 °C
4 x AAA
300 hours
3 years
193.8 x 92.2 x 58.0 mm
–10 to 55 °C
4 x AAA
300 hours
3 years
193.8 x 92.2 x 58.0 mm
Safety and regulatory
Over-voltage safety protection
EN/IEC 61010-1:2001
compliance
CSA C22.2 No. 61010-1:2004
compliance
General
Operating temperature
Battery (included)
Battery life
Warranty
Dimensions (H x W x D)
represents key specifications/features
For complete specifications, please refer to data sheet 5989-7040EN
Web link
www.agilent.com/find/handhelddmm
How to ?
Detect Harmonics in AC signals
http://cp.literature.agilent.com/litweb/pdf/5989-7687EN.pdf
Select a Handheld DMM that is Right for You
http://cp.literature.agilent.com/litweb/pdf/5990-5197EN.pdf
U1250 Series - Handheld Digital Multimeters
The process of isolating faults is always unpredictable—so it’s good to be equipped
with a versatile DMM that simplifies analysis, accelerates glitch detection and
makes it easier to probe hard-to-reach points. The U1250 Series gets even better
with the U1253B DMM and its razor-sharp OLED display: You’ll get crystal-clear
readings indoors, even in dark, off-angle situations. Optimize electronics troubleshooting with the accuracy, capabilities, and accessories you need to get started
in no time.
Features
•
•
•
•
•
•
•
High contrast ratio of 2000:1 and wide viewing angle of 160°*
50,000 counts high resolution and up to 0.025% low error rate
Built-in square-wave generator and frequency counter
Includes all essential accessories for electronics troubleshooting
Smoothing function to stabilize erratic readings*
Data logging to instrument and PC
Bluetooth wireless connectivity (optional U1177A Infrared (IR)-to-Bluetooth Adapter required)
* with U1253B
A testament to innovation
and credibility, 2006
Best Value Portable
Test Equipment, 2006
General-purpose instruments
category, 2009
11
Category Winner, EC&M Product
of the Year competition, 2009
Applications with the U1250 Series Handheld Digital Multimeters
Automated data logging to PC for long, continuous measurements
Qualification and troubleshooting of a
device-under-test (DUT) often require
long periods of testing, over either different temperatures or parameter settings. A
common test would be voltage measurements at room, hot and cold temperatures. In such cases, it’s more convenient
and efficient to automate recording of
measurements while you perform other
tasks that are at hand. It’s even better if
you can record as many data points as
required without worrying about the storage capacity of the measuring equipment.
Whatever your measurements, the U1250
Series lets you make easy automated data
logging with virtually unlimited saves
to PC—so you can be assured that faults
are recorded dependably and analyzed
sooner.
Event logging setup in minutes—with bundled GUI data-logging software
Connect the optional U1173A IR-USB cable to your
U1250 Series DMM and PC
Open up the GUI data-logging interface
Click on
Click on
and then
to start data logging
Data viewable in both graphical and tabular formats
What others say
“I can view rapidly changing readings easily with the U1252A’s speedy update rate. Its stable voltage/current/resistance readings
offer accurate results, particularly for microvolt measurements of load cells.”
James G. DuPuy, Service Engineer, Brechbuler Scales Inc. manufacturer of industrial weighing systems and scales
12
Built-in square-wave generator for designing and troubleshooting motor drivers
In the motor-driver circuit shown, a
signal from the pulse-width modulation
(PWM) inverter drives the motor and is
fed back to the speed controller circuit.
In design and troubleshooting applications, these pulses are generated
externally—usually with a function
generator or pulse generator—and
injected into the circuit to simulate
actual pulses from the inverter.
PWM
inverter
Vdc
Rotor flux
reference
With the U1250 Series, you can easily
configure the square-wave output of
the U1252B to generate simple PWM
signals—conveniently in one portable,
lightweight instrument.
Motor
Speed
sensor
Current
controllers
ids
calculation
dq
abc
iqs
calculation
calculation
Torque
reference
Rotor flux
calculation
dq
abc
Speed
controller
Speed reference
What others say
“We used square-wave output from the DMM for operational checks of digital circuits around an FPGA to verify the power source of a satellite tracking
device and the reception signal from GPS. The U1252A makes our job easier by providing multiple measurements and very accurate results.”
Hashiguchi, Engineer, ELM Inc., Japan – developer of satellite tracking and other system devices
Specifications of the U1250 Series Digital Multimeters
U1251B
U1252B
U1253B
N/A
Yes
50,000 (both displays)
Yes
Yes
N/A
Yes
50,000 (both displays)
Yes
Yes
Yes
Yes
50,000 (both displays)
Yes
N/A
AC
0.03%
Yes
AC+DC
0.025%
Yes
AC+DC
0.025%
Yes
Display
Organic LED
Dual display
Counts
Analog bar graph
Backlight
Basic features
True RMS
Basic DCV accuracy
Auto/Manual ranging
Measurements
Voltage AC/DC
Current AC/DC
Resistance
Frequency
Capacitance
Temperature
Continuity with beeper
Diode test
4-20 mA % scale
dB
Frequency counter
Smoothing function
1000 V
10 A
50 MΩ
1 MHz
0.001 nF to 100 mF
1372 °C, K-type thermocouple
Yes
Yes
Yes
Yes
N/A
N/A
1000 V
10 A
500 MΩ
20 MHz
0.001 nF to 100 mF
1372 °C, J/K-type thermocouple
Yes
Yes
Yes
Yes
Yes
N/A
represents key specifications/features
13
1000 V
10 A
500 MΩ
20 MHz
0.001 nF to 100 mF
1372 °C, J/K-type thermocouple
Yes
Yes
Yes
Yes
Yes
Yes
Specifications of the U1250 Series Digital Multimeters Continued
U1251B
U1252B
U1253B
N/A
0.5 Hz to 4.8 kHz,
selectable Hz and %
0.5 Hz to 4.8 kHz,
selectable Hz and %
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
Internal: 100 manual,
200 interval points
To PC: virtually unlimited
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
Internal: 100 manual,
200 interval points
To PC: virtually unlimited
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
Internal: 100 manual,
1000 interval points
To PC: virtually unlimited
CAT III 1000 V/CAT IV 600 V
Yes
CAT III 1000 V/CAT IV 600 V
Yes
CAT III 1000 V/CAT IV 600 V
Yes
Yes
Yes
Yes
–20 to 50 °C
Alkaline 9 V
72 hours
IR-USB
3 years
203.5 x 94.4 x 59.0 mm
–20 to 50 °C
7.2 V Ni-MH rechargeable
36 hours
IR-USB
3 years
203.5 x 94.4 x 59.0 mm
–20 to 50 °C
7.2 V Ni-MH rechargeable
8 hours
IR-USB
3 years
203.5 x 94.4 x 59.0 mm
Signal generation
Square-wave generator
Data management
Min/Max/Avg recording
Peak recording
Data hold
Null
Connectivity
Data logging
(requires IR-to-USB cable
U1173A for connection to PC)
Safety and regulatory
Over-voltage safety protection
EN/IEC 61010-1:2001
compliance
CSA C22.2 No. 61010-1:2004
compliance
General
Operating temperature
Battery (included)
Battery life
I/O
Warranty
Dimensions (H x W x D)
represents key specifications/features
For complete specifications, please refer to data sheet 5989-5509EN
Web link
www.agilent.com/find/handhelddmm
How to ?
Get the Best Out of the U1250 Series Handheld DMM
http://cp.literature.agilent.com/litweb/pdf/5989-7937EN.pdf
Think Safety When Selecting a Handheld Multimeter
http://cp.literature.agilent.com/litweb/pdf/5990-4578EN.pdf
Select a Handheld DMM That is Right for You
http://cp.literature.agilent.com/litweb/pdf/5990-5197EN.pdf
14
U1270 Series – Handheld Digital Multimeters
The U1273AX, the latest addition to the U1270 series is capable of operating down to -40°C in temperature. Even in extremely
cold conditions, the U1273AX handheld DMM delivers immediate and accurate results—no warm-up time required.
All models are ergonomically-built providing useful functions such as ZLOW,
which eliminates stray voltages, and Smart Ohm that minimizes false readings from residual voltage induced by leakage current. All of this is designed
into a case that fulfills the needs of today's industrial handheld users.
Features
• OLED display with 2000:1 contrast ratio and 160 degree viewing angle 1,2
• 30,000 counts resolution
• Measure up to 1000 V AC and DC
• Measure up to 10 A (20 A for 30 s)
• Resistance, diode test, temperature, capacitance
• Low Impedance mode 1,2,3 and Low Pass Filter
• −40 to 55 °C operating temperature 2
• Up to 3000 m operating altitude
• Water and dust resistance (IP 54)
• CAT III 1000 V / CAT IV 600 V safety rating
• Bluetooth wireless connectivity with optional U1177A Bluetooth
1. U1273A
2. U1273AX
3. U1272A
Applications with U1270 Series Handheld Digital Multimeters
Key functions
Low Pass Filter (LPF)
In alternating current (AC) electric motor
related applications such as the temperature control system in chiller rooms or conveyor drives, the efficiency of the motor is
very important to reduce operating costs
and improve productivity. Therefore, technicians need to perform routine servicing
and repairs on the motors and variablefrequency drive (VFD). The VFD is especially important as it controls the rotational
speed of the electric motor by regulating
the frequency of the electrical power supplied to the motor.
Sometimes, a maintenance check on the
motor and VFD reveals that the actual
output voltage and frequency from the
VFD differs from the readings on the VFD
display. This shows that the VFD might be
faulty and may therefore need replacement or repair. The difference in voltage
readings could also be contributed by
harmonics produced by the output of the
VFD. This problem must be addressed
quickly because if this situation prolongs,
the motor may overheat and eventually
fail, causing downtime.
It is difficult to identify the root cause of
this error using a typical wide bandwidth
handheld digital multimeter (DMM).
A handheld multimeter with a built-in
low pass filter would help technicians
to quickly determine if the problem is
contributed by unwanted high frequency
components generated by the VFD. The
Agilent U1270 Series handheld DMMs
offer a 1 kHz low pass filter to provide
accurate VFD output measurement.
This function eliminates unwanted high
frequency noise signals and components
generated by the VFD. Therefore, a
technician would be able to reduce
troubleshooting time and ultimately
reduce system downtime.
Comparison of voltage output from industrial motor VFD without and with
Low Pass Filter functionality.
15
Smart Ω
Low impedance mode (ZLOW)
Electrical conduit is commonly found in
buildings, from manufacturing plants to
residential homes. It provides enclosed
conductors protection from moisture,
chemical vapors and impact. The use
of electrical conduit simplifies wiring
changes as existing conductors can be
withdrawn and new conductors installed
with little disruption along the path of the
conduit.
Although convenient and safe, unused
wires can sometimes run parallel with
energized wiring. This may induce
capacitive coupling between these wires,
causing an undesirable transfer of energy
from the energized wiring to the unused
wiring. This complicates installation or
maintenance of electrical wiring as voltage may be detected on the unused wiring. This is known as ‘stray voltage’. This
causes complications for technicians, who
would have to spend time troubleshooting
or isolating wires in order to determine
the source of the voltage.
Multimeters with a low impedance mode
are able to identify the presence of stray
voltages in non-energized wiring. The
low impedance mode eliminates false
readings by providing a load to the circuit
during voltage testing.
The Agilent U1272A/U1273A are dual
impedance digital multimeters, offering
both high and low impedance modes. The
DMM’s high impedance function can be
used in most electrical measurements in
the industrial environment because it will
not load the circuit under test. Switching
to the low impedance mode allows the
U1272A/U1273A to perform accurate
measurements on circuits that may contain stray voltages. This eliminates the
need of an additional low impedance
multimeter, such as a solenoid tester. If
this mode is used when real voltage is
present, the Agilent U1272A/U1273A has
a built-in positive temperature coefficient
(PTC) thermistor as an overcurrent protection element.
In integrated circuit (IC) manufacturing
plants, ground continuity measurements
on workstations are important to ensure
that electrostatic discharge (ESD) is minimized. As electronic components become
further miniaturized, these components
are more sensitive to ESD. In order to
maintain a workstation, the common
ground point for continuity to earth or
electrical ground should be checked
periodically.
During this continuity check, leakage
current may be found flowing through
the common ground conductor to earth
ground. This leakage current causes
inaccurate ground continuity measurement.
The Agilent U1272A/U1273A handheld
digital multimeters (DMM) allow you to
read the leakage current with its Smart
Ω function. With the U1272A/U1273A's
dual display and 30 Ohms range, you can
obtain accurate resistance measurement
and read leakage current simultaneously.
Specifications of the U1270 Series Digital Multimeters
Di
U1271A
U1272A
U1273A
U1273AX
30,000
LCD
Yes
Yes
Yes
20 kHz
AC
30,000
LCD
Yes
Yes
Yes
100 kHz
AC + DC
30,000
OLED
Yes
Yes
Yes
100 kHz
AC + DC
30,000
OLED
Yes
Yes
Yes
100 kHz
AC + DC
300 mV to 1000 V
0.05% + 2 cnts
300 mV to 1000 V
0.7% + 20 cnts
45 Hz to 20 kHz
300 µA to 10 A
0.2% + 5 cnts
300 µA to 10 A
0.9% + 25 cnts
45 Hz to 2 kHz
300 Ω to 100 MΩ
0.2 % + 5 cnts
99.999 Hz to 999.99 kHz
0.005% + 5 cnts
30 mV to 1000 V
0.05% + 2 cnts
30 mV to 1000 V
0.6% + 20 cnts
45 Hz to 100 kHz
300 µA to 10 A
0.2% + 5 cnts
300 µA to 10 A
0.6% + 25 cnts
45 Hz to 2 kHz
30 Ω to 300 MΩ
0.2% + 5 cnts
99.999 Hz to 999.99 kHz
0.005% + 5 cnts
30 mV to 1000 V
0.05% + 2 cnts
30 mV to 1000 V
0.6% + 20 cnts
45 Hz to 100 kHz
300 µA to 10 A
0.2% + 5 cnts
300 µA to 10 A
0.6% + 25 cnts
45 Hz to 2 kHz
30 Ω to 300 MΩ
0.2% + 5 cnts
99.999 Hz to 999.99 kHz
0.005% + 5 cnts
30 mV to 1000 V
0.05% + 2 cnts
30 mV to 1000 V
0.6% + 20 cnts
45 Hz to 100 kHz
300 µA to 10 A
0.2% + 5 cnts
300 µA to 10 A
0.6% + 25 cnts
45 Hz to 2 kHz
30 Ω to 300 MΩ
0.2% + 5 cnts
99.999 Hz to 999.99 kHz
0.005% + 5 cnts
Basic features
Display resolution
Display type
Auto/manual ranging
Analog bar graph
Backlight
AC bandwidth
True RMS
Measurements
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Frequency
Range
Accuracy
Range
Accuracy
Bandwidth
Range
Accuracy
Range
Accuracy
Bandwidth
Range
Accuracy
Range
Accuracy
16
Specifications of the U1270 Series Digital Multimeters Continued
Di
U1271A
U1272A
U1273A
U1273AX
10 nF to 10 mF
1% + 2 cnts
K: –200 to 1372 °C
1% + 1 °C
Yes
Yes
10 nF to 10 mF
1% + 2 cnts
K: –200 to 1372 °C
J: –210 to 1200 °C
1% + 1 °C
Yes
Yes
10 nF to 10 mF
1% + 2 cnts
K: –200 to 1372 °C
J: –210 to 1200 °C
1% + 1 °C
Yes
Yes
10 nF to 10 mF
1% + 2 cnts
K: –200 to 1372 °C
J: –210 to 1200 °C
1% + 1 °C
Yes
Yes
Yes
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
Yes
Yes
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
Yes
Yes
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
Yes
Yes
Yes
Yes
Yes
Yes
IR-USB/Bluetooth
Yes
—
Yes
Yes
N/A
N/A
Yes
—
Yes
Yes
Yes
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
Yes
Yes
Yes
N/A
CAT III 1000 V, CAT IV 600 V
Yes
Yes
CAT III 1000 V, CAT IV 600 V
Yes
Yes
CAT III 1000 V, CAT IV 600 V
Yes
Yes
CAT III 1000 V, CAT IV 600 V
Yes
Yes
–20 to 55 °C, 0 to 80% RH
3000 m
4 x AAA alkaline
300 hours
3 years
207.0 x 92.0 x 59.0 mm
–20 to 55 °C, 0 to 80% RH
3000 m
4 x AAA alkaline
300 hours
3 years
207.0 x 92.0 x 59.0 mm
–20 to 55 °C, 0 to 80% RH
3000 m
4 x AAA alkaline
30-60 hours
3 years
207.0 x 92.0 x 59.0 mm
–40 to 55 °C, 0 to 80% RH
3000 m
4 x AAA lithium
50-100 hours
3 years
207.0 x 92.0 x 59.0 mm
Measurements Continued
Range
Accuracy
Range
Accuracy
Capacitance
Temperature
Continuity with beeper
Diode test
Data management
Min/max recording
Display hold
Peak hold
Manual datalogging
Null
Connectivity
% scale of 4-20 mA
Special features
OLED display
Beep + visual alert
Low pass filter (LPF)
ZLOW - low impedance mode
Smart Ω
Qik-V
Safety and regulatory
Over-voltage safety protection
EN/IEC 61010-1:2001 compliance
CSA C22.2 No. 61010-1:2004 compliance
General
Operating temperature
Altitude
Battery (included)
Battery life
Warranty
Dimensions (H x W x D)
represents key specifications/feature
For complete specifications, please refer to data sheet 5990-6425EN
Web link
www.agilent.com/find/handhelddmm
www.agilent.com/find/U1273AX
http://wireless.agilent.com/videos/u1270/index.html
How to?
Test for Stray Voltage Using the U1272A
http://cp.literature.agilent.com/litweb/pdf/5990-6517EN.pdf
Ground Resistance Measurement with Smart Ohm
http://cp.literature.agilent.com/litweb/pdf/5990-7323EN.pdf
17
U1190 Series – Clamp Meters
Agilent’s U1190 Series clamp meters are packed with a wealth of
features to help you work more efficiently and more safely. Housed in
robust cases, each model comes with an innovative wire separator that
helps you isolate and measure individual wires in a bundle. The built-in
LED flashlight illuminates your test area and Vsense performs non-contact
voltage detection. The clamp meters are also certified with both CAT III
600 V and CAT IV 300 V ratings to cover wider measurement categories.
Features
•
•
•
•
•
Unique wire separator to separate wires from a bundle
Vsense to perform non-contact voltage detection1
Built-in LED flashlight to illuminate test area1
Current measurement up to 600 A2
Digital multimeter (DMM) with Resistance, Capacitance1,
DCV, ACV, DCμA3, ACμA3, Continuity and Diode test measurements
• CAT III 600 V / CAT IV 300 V safety ratings
1. Only for U1192A, U1193A and U1194A
2. Only for U1193A and U1194A
3. Only for U1194A
CAT III 600 V
CAT IV 300 V
Application with U1190 Series Clamp Meters
Convenient and affordable clamp meters – for electricians in commercial or
residential electrical installation and maintenance
Basic current measurement is an essential
task for electricians working in commercial or residential electrical installation
and maintenance. These electricians need
an affordable yet versatile tool to help
them conveniently install and troubleshoot
various applications such as wire installation at distribution transformers, panel
circuit controller, or even troubleshooting
electrical motor.
The U1190 Series clamp meters comes
with an innovative ‘wire separator’
design that enables electricians to easily
clamp on a targeted wire. Designed with
a pointed tip, the wire separator allows
users to isolate an individual wire from
a bundle. In this way, the user does not
have to manually use his hands to isolate
the targeted wire for current measurements, hence eliminating the risk of
getting into contact with live wires. All
models also come with basic digital multimeter functions for electricians that need
quick access to basic voltage, resistance,
capacitance, continuity, diode and frequency tests.
Integrated with a LED flashlight, the
U1190 Series clamp meters allow electricians to illuminate the test area while
clamping on the wire. The built-in LED
flashlight enables electricians to work
safer even in dark or poorly lit environ18
The built-in flashlight illuminates
test area
ments. Each clamp meter is certified with
CAT III 600 V / CAT IV 300 V safety rating
to cover wider measurement categories.
Specifications of the U1190 Series Clamp Meters
Di
Basic features
U1191A
U1192A
U1193A
U1194A
6,000
Average Responding
6,000
Average Responding
6,000
True RMS
6,000
True RMS
600 V
600 V
N/A
N/A
400 A
N/A
600 Ω to 6 kΩ
N/A
1.5 V
600 Ω
N/A
N/A
60 to 600 V
60 to 600 V
N/A
N/A
40 to 600 A
N/A
600 Ω to 60 kΩ
600 µF to 6 mF
1.5 V
600 Ω
N/A
99.99 Hz to 99.99 kHz
60 to 600 V
60 to 600 V
N/A
N/A
60 to 600 A
N/A
600 Ω to 60 kΩ
600 µF to 6 mF
1.5 V
600 Ω
N/A
99.99 Hz to 99.99 kHz
60 to 600 V
60 to 600 V
60 to 600 A
60 to 600 µA
60 to 600 A
60 to 600 µA
600 Ω to 60 kΩ
600 µF to 6 mF
1.5 V
600 Ω
K-type: –40 °C to 1200 °C
99.99 Hz to 99.99 kHz
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Backlight
Auto power OFF
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Wire separator
Yes
Yes
Yes
Yes
Built-in flashlight
Vsense
No
No
Yes
Yes
Yes
Yes
Yes
Yes
CAT III 600 V /
CAT IV 300 V
CAT III 600 V /
CAT IV 300 V
CAT III 600 V /
CAT IV 300 V
CAT III 600 V /
CAT IV 300 V
Yes
Yes
Yes
Yes
–10 to 50 °C,
0 to 80% RH
1.5 V
200 hours
3 years
225.0 x 77.1 x 38.6 mm
31 mm
27 mm
–10 to 50 °C,
0 to 80% RH
1.5 V
200 hours
3 years
225.0 x 77.1 x 38.6 mm
31 mm
27 mm
–10 to 50 °C,
0 to 80% RH
1.5 V
200 hours
3 years
238.0 x 77.1 x 38.6 mm
37 mm
35 mm
–10 to 50 °C,
0 to 80% RH
1.5 V
200 hours
3 years
238.0 x 77.1 x 38.6 mm
37 mm
35 mm
Counts
RMS method
Measurement range
DC voltage
AC voltage
DC A current
DC µA current
AC current
AC µA current
Resistance
Capacitance
Diode
Continuity
Temperature
Frequency
Data management
Data hold
Null
MAX/MIN/AVG
Auto/Range
Other features
Safety and regulatory
Over-voltage safety protection
EN/IEC 61010-1, CE,
CSA compliance
General
Operating temperature
Battery (included)
Battery life
Warranty
Dimensions (H x W x D)
Clamp opening
Clamping diameter
represents key specifications/features
For complete specifications, please refer to data sheet 5990-8646EN
Web link
www.agilent.com/find/clampmeter
www.agilent.com/find/U1190clamp
19
U1210 Series – Handheld Clamp Meters
Measurements of electrical distribution cables can be challenging and
risky. For cables up to two inches in diameter, the Agilent U1210 Series
handheld clamp meters enable high-current measurements without
breaking the circuit. Unlike most clamp meters, they also include DMM
capabilities—resistance, capacitance, frequency and temperature—to
simplify troubleshooting during installation and maintenance. Best of all,
they provide an extra layer of protection with CAT IV 600 V and CAT III
1000 V safety ratings.
Features
• Large clamp opening of 52 mm or 2 "
• High measurement capability of up to 1000 A for AC, DC or AC+DC
• CAT III 1000 V/CAT IV 600 V safety rating
• Includes full-featured DMM with resistance, capacitance, frequency
and temperature functions
• High resolution measurements - measure current as low as 0.01 A
• Peak hold capability
• Bluetooth wireless connectivity (optional U1177A Infrared (IR)-to-Bluetooth Adapter required)
Applications with U1210 series Handheld Clamp Meters
Smooth sailing current
measurements even in a distance
Making current measurements can
be strenuously demanding due to its
complexity and high current involved.
Electrical distribution rooms being typically situated at different areas further complicates maintenance and troubleshooting.
This is due to the need for electricians to
commute back and forth in order to cross
check measurement results.
Now you can make high current measurements in a safer and more convinient
manner by adding the new Bluetooth
capability to your existing U1210 series
handheld clamp meters. The U1177A
Infrared-to-Bluetooth adapter allows
you to easily monitor measurements and
log data up 10-metres range across all
Android platform devices. Simplify your
day to day task with a value added device
for maximum efficiency and productivity in
all sorts of hard-to-reach environments.
20
Large jaw opening and high-current measurement capability for installation and maintenance of high-current distribution systems and cables
Current measurements at power distribution sites can be challenging as cables are
usually large as they contain high current
sources. The need of current measurement methods that are safe and easy add
complexity to the task of acquiring accurate
current data. Conventionally, a current
conductor has to be disconnected to allow
probe insertion and this is not only hazardous when high currents are involved, but
not convenient as well.
With a two-inch (52 mm) jaw opening,
the U1210 Series handheld clamp meters
simplify current measurements for thick
cables, without breaking the circuit. The
clamp meters provide the ability to handle
big currents, with current measurement
capability of up to 1000 A (AC, DC,
AC+DC). This series also enables high
resolution measurements, with the ability
to measure currents as low as 0.01 A. You
are able to measure in-rush current as well
with the clamp meters’ peak hold feature.
The U1210 Series clamp meters offer
dual-ranging mode – manual and auto,
min/max recording capability and large
dual display for additional accessibility
when it comes to data collection
or analysis.
Each clamp meter provides an extra layer
of protection with CAT IV 600 V and CAT
III 1000 V safety ratings. When performing
a measurement with the multimeter, test
probes with 4-mm tips (which is bundled
with each clamp meter) can be used to
further prevent dangerous arc flash if the
tips are inadvertently shorted together
during probing.
4-mm-tip probes
21
Full-featured digital multimeter functions – make more than just current measurements
The U1210 Series clamp meters are
versatile handheld test tools that combine
a current clamp with a digital multimeter
(DMM).
The U1210 Series provides basic
functions of a multimeter with wide
measurement ranges to cater for a broad
range of applications: ACA, DCV, ACV,
OHM, audible continuity, capacitance,
diode and frequency tests.
These meters also provide auto-ranging
capability, built-in peak hold for in-rush
current measurement, temperature and
capacitance measurement capability,
large backlight display and one-hand
operation.
Specifications of the U1210 Series Clamp Meters
U1211A
U1212A
U1213A
Yes
4000
12 segments
Yes
Yes
Yes
4000
12 segments
Yes
Yes
Yes
4000
12 segments
Yes
Yes
AC
Yes
AC/DC
Yes
AC+DC
Yes
0.1 - 1000 V (0.5%)
0.1 - 1000 V (1.0%)
N/A
0.1 - 1000 A (1.0%)
4 kΩ (0.5%)
0.1 - 4000 µF (2.0%)
Yes
N/A
Yes
N/A
0.1 - 1000 V (0.5%)
0.1 - 1000 V (1.0%)
0.01 - 1000 A (1.5%)
0.1 - 1000 A (2.0%)
4 kΩ (0.5%)
0.1 - 4000 µF (2.0%)
Yes
K-type (–200 to 1372 °C)
Yes
N/A
1 mV - 1000 V (0.2%)
1 mV - 1000 V (1.0%)
0.01 - 1000 A (1.5%)
0.01 - 1000 A (2.0%)
40 MΩ (0.3%)
1 - 4000 µF (1.0%)
Yes
K-type (–200 to 1372 °C)
Yes
Yes
Display
Dual display
Counts
Bar-graph
Backlit
Auto power OFF
Basic features
True RMS
Auto/manual ranging
Measurements
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Diode
Temperature
Frequency
Duty cycle
Accuracy information shown in brackets is the best accuracy throughout the range.
represents key specifications/features
22
Specifications of the U1210 Series Clamp Meters Continued
U1211A
U1212A
U1213A
Yes
Yes
Yes
Yes
Bluetooth
Yes
Yes
Yes
Yes
Bluetooth
Yes
Yes
Yes
Yes
Bluetooth
CAT III 1000 V/CAT IV 600 V
CAT III 1000 V/CAT IV 600 V
CAT III 1000 V/CAT IV 600 V
Yes
Yes
Yes
Yes
Yes
Yes
–10 to 50 °C
2"
Alkaline 9 V
60 hours
3 years
273.0 x 106.0 x 43.0 mm
–10 to 50 °C
2"
Alkaline 9 V
60 hours
3 years
260.0 x 106.0 x 43.0 mm
–10 to 50 °C
2"
Alkaline 9 V
60 hours
3 years
260.0 x 106.0 x 43.0 mm
Data management
Data hold
Null
MAX/MIN/AVG
Peak hold
Connectivity
Safety and regulatory
Over-voltage safety
protection
EN/IEC 61010-1:2001
compliance
CSA C22.2 No. 61010-1:2004
compliance
General
Operating temperature
Clamp opening
Battery (included)
Battery life
Warranty
Dimensions (H x W x D)
represents key specifications/features
For complete specifications, please refer to data sheet 5990-3459EN
Web link
www.agilent.com/find/clampmeter
How to ?
Troubleshoot Three-Phase AC Motors with U1210 Series Handheld Clamp Meters
http://cp.literature.agilent.com/litweb/pdf/5990-5192EN.pdf
23
Digital Oscilloscopes
U1600 Series - Handheld Digital Oscilloscopes
A scope with a color waveform display. A DMM for basic measurements.
A data logger to record DMM readings to a PC. All three capabilities are
in one instrument—the U1600 Series of handheld digital oscilloscopes.
Designed to address the portability needs of various installation and
maintenance applications, these scopes enable clear waveform viewing,
easy waveform analysis and quick isolation of signal glitches. With
high-performance features loaded into one robust package, mobile
troubleshooting is a breeze.
Features
•
•
•
•
•
•
Built-in DMM and data logger
Large 4.5 " color display
200 MSa/s high sampling rate and deep memory
Built-in Quick Help, available in multiple languages
Data logging to instrument and PC
Convenient data download to USB flash drive*
No. 1 Product of the Year
as voted by readers—2006
* with Option 001
Applications with the U1600 Series Handheld Digital Oscilloscopes
Fast sampling, deep memory—so you won’t miss a glitch
Whether a machine is down for repair
or maintenance, returning it to service
as quickly as possible is crucial. With the
U1600 Series, you can carry a scope to
the problem knowing you can make measurements without an AC outlet.
One common fault in the printed circuit
board assembly (PCA) of such machines
is glitches caused by factors ranging from
component wear-and-tear to an unclean
power source. Effectively capturing these
glitches requires a scope with a high
sampling rate and deep memory.
The U1600 Series provides 20 MHz
24
and 40 MHz bandwidths with up to
200 MSa/s real-time sampling rate. With
its deep memory, you can zoom in on a
particular segment of a signal to view
even the most subtle details. The scopes
also offer advanced triggering types such
as edge, pulse width, pattern and video to
assist in quick isolation of critical events.
Advanced FFT and waveform math follow wherever you go
Time is especially precious on the manufacturing line. When a test system fails,
quick troubleshooting and analysis is
needed to get the line running again as
soon as possible.
The portable, lightweight U1600 Series
is more convenient than conventional
benchtop oscilloscopes. Its small form
adds versatility when measuring hardto-reach points in the test system, and
its large color LCD display enables clear
viewing of waveforms.
Analysis of complex waveforms is easy
with the U1600 Series’ dual waveform
math (DWM) and fast Fourier transform
(FFT) functions. The FFT function provides
a frequency-domain view of measurements in four windowing techniques:
Rectangular, Hanning, Hamming and
Blackman-Harris.
An FFT of the upper waveform reveals three spectral lines
that represent the carrier frequency and its sidebands, enabling
informative analysis of amplitude-modulated signals.
Although the sine-wave signal seems flawless in the time
domain, doing an FFT reveals the presence of harmonic
distortion, which is seen as integer-multiple spectral
components in the frequency domain.
25
Specifications of the U1600 Series Digital Oscilloscopes
U1602B
U1604B
4.5” color LCD
6000
4.5” color LCD
6000
2
DC to 20 MHz
2
DC to 40 MHz
200 MSa/s interleave
100 MSa/s each channel
200 MSa/s interleave
100 MSa/s each channel
125 Kpts
125 Kpts
Yes
Yes
Yes
N/A
Up to 22 measurements
AC, DC, GND
1 MΩ I I < 20 pF
50 ns to 50 s/div
2 ns
< 17.5 ns
Edge, Pattern, Pulse width, Video
Auto, Normal, Single
Up to 10 setups and traces
Yes
Rectangular, Hamming, Hanning, Blackman-Harris
Up to 22 measurements
AC, DC, GND
1 MΩ I I < 20 pF
10 ns to 50 s/div
400 ps
< 8.8 ns
Edge, Pattern, Pulse width, Video
Auto, Normal, Single
Up to 10 setups and traces
AC+DC
600 V
600 A
60 MΩ
0.01 nF to 300 µF
6000 °C, K-type thermocouple
Yes
Yes
AC+DC
600 V
600 A
60 MΩ
0.01 nF to 300 µF
6000 °C, K-type thermocouple
Yes
Yes
Yes
Yes
Display
General
Counts (DMM function)
Scope
Channels
Bandwidth (–3 dB)
Maximum sampling rate
Single Channel Operation
Dual Channel Operation
Maximum recording length
Single Channel Operation
Dual Channel Operation
Cursor and zoom
functions
Waveform math
FFT
Automatic measurements
Coupling
Input impedance
Range
Resolution
Rise time
Trigger types
Trigger modes
Internal scope storage
DMM
True RMS
Voltage AC/DC
Current AC/DC
Resistance
Capacitance
Temperature
Continuity with beeper
Diode test
Data logger
Min/Max/Avg recording
Data logging
(requires bundled USB 2.0
full-speed cable for
connection to PC
Time span
Internal: 250 points
To PC: virtually unlimited
Internal: 250 points
To PC: virtually unlimited
150 seconds to 20 days (auto range)
represents key specifications/features
26
150 seconds to 20 days (auto range)
Specifications of the U1600 Series Digital Oscilloscopes Continued
U1602B
U1604B
CAT III 300 V
CAT III 300 V
Yes
Yes
Yes
Yes
Safety and regulatory
Over-voltage safety
protection
EN/IEC 61010-1:2001
compliance
CSA C22.2 No. 610101:2004 compliance
General
Operating temperature
Battery (included)
Battery life
I/O
•
Warranty
Dimensions (H x W x D)
0 to 50 °C
Rechargeable Ni-MH
4 hours
• USB 2.0 full-speed client for data transfers to PC
USB 2.0 full-speed host for data transfers to USB flash drive
(Option 001)
3 years
241.0 x 138.0 x 66.0 mm
•
0 to 50 °C
Rechargeable Ni-MH
4 hours
• USB 2.0 full-speed client for data transfers to PC
USB 2.0 full-speed host for data transfers to USB flash drive
(Option 001)
3 years
241.0 x 138.0 x 66.0 mm
For complete specifications, please refer to data sheet 5989-5576EN
Web link
www.agilent.com/find/handheldscope
How to ?
Perform Metal Scrap Sorting Machine Installation with U1600A Series
http://cp.literature.agilent.com/litweb/pdf/5989-9786EN.pdf
U1610A/U1620A- Handheld Digital Oscilloscopes
Agilent's U1610A/U1620A is the world’s first handheld
oscilloscope with a VGA display. With a bandwidth
of 100/200 MHz, the handheld oscilloscope offers a
floating measurement capability with two CAT III 600
V isolated channels. With up to 2 GSa/s sampling rate
and 2 Mpts memory depth, it captures more waveforms
from signals such as pulse width modulated circuit,
in-rush, transient, and motor start up sequences. The
benchtop-like display and dual window zoom function
allow you to easily identify problem areas and zoom in
for more detailed analysis. Now, you can view signals
in detail and detect glitches easily.
NEW
Features
•
•
•
•
•
•
•
100/200 MHz bandwidth with two isolated channels
5.7 " VGA TFT LCD display with 3 selectable viewing modes (indoor, outdoor and night vision)
Up to 2 Mpts memory depth and 2 GSa/s sampling rate allows detailed analysis of captured glitches
10,000-count resolution on DMM display
Channel-to-channel isolation with CAT III 600 V safety ratings
Data logging capability and USB connectivity
Up to 10 selectable languages on the User Interface (UI)
27
Applications with the U1610A/U1620A Handheld Digital Oscilloscope
View even the most subtle details- with fast sampling rate and deep memory
A good oscilloscope must be accompanied with fast sampling rate and
deep memory depth, because these
two go hand-in-hand. With deep
memory of 2Mpts and sampling rate
of 2 GSa/s, non-repeating signals can
be captured over a wider time base,
allowing you to zoom into specific
areas of interest. What’s more, its
dual window zoom feature display
allows you to work more productively
by simultaneously viewing signals
captured over a period of time and
zooming into the most subtle details.
Other features include advanced
triggering types such as edge, pulse
width, CAN and video to assist in
quick isolation of critical events.
Three viewing modes for optimized viewing under all lighting conditions
Viewing waveforms in clarity is
important, especially for an oscilloscope which is a visual tool.
This is why our U1610A/U1620A
oscilloscope comes with a 5.7 " VGA
TFT LCD display that enables clear
viewing of measurements on-site and
on the field. With the option of up to
three viewing modes, users can now
view signals under all lighting condi-
tions, including in indoor, outdoor or
dark environments. All three viewing
modes have predefined contrast levels for customized lighting conditions
and optimized battery life.
Indoor mode
Outdoor mode
Night vision mode
The indoor mode has high contrast
and brightness levels to clearly distinguish waveforms under the indoor
light environment. Furthermore, the
TFT LCD technology enables the
screen to be viewed across wide
viewing angles for more efficient
troubleshooting task.
When performing field work in an
outdoor environment, users can
easily switch to this viewing mode
via a set of accessible soft keys. This
mode works in an anti-glare mechanism; it filters out excessive sunlight,
hence reducing the risk of misreading
or misinterpreting measurements
under broad day light.
The night vision mode is tailored to
be viewable under subdued lighting
by enabling high contrast of the
screen background against waveforms. By switching into this mode,
the screen automatically adjust with
proper colour correction, making the
waveforms
viewable.
This mode is
useful when
measuring
high speed
signals,
particularly in
non-repetitive
signals.
Specifications of the U1610A/U1620A Digital Oscilloscope
U1610A
U1620A
5.7 ” colour VGA TFT LCD
10,000
5.7 ” colour VGA TFT LCD
10,000
2
100 MHz
2
200 MHz
1 GSa/s interleave
500 MSa/s each channel
2 GSa/s interleave
1 GSa/s each channel
120 Kpts interleave
60 Kpts each channel
Yes
2 Mpts interleave
1 Mpts each channel
Yes
Display
General
Counts (DMM function)
Scope
Channels
Bandwidth
Maximum sampling rate
Single Channel Operation
Dual Channel Operation
Maximum recording length
Single Channel Operation
Dual Channel Operation
Cursor and Zoom functions
represents key specifications/features
28
Specifications of the U1610A/U1620A Digital Oscilloscope Continued
U1610A
U1620A
CH1 + CH2, CH1 – CH2, CH2 – CH1, CH1 × CH2,
CH1/CH2, CH2/CH1, d/dt (CH1), d/dt (CH2), ∫(CH1)
dt, ∫(CH2)dt, FFT
Yes
Up to 24 measurements
DC, AC
1 MΩ ± 1% ≈ 22 pF ± 3 Pf
5 ns/div to 50 s/div
8-bits
3.50 ns typical
Edge, Glitch, TV, Nth Edge, CAN, LIN
Normal, Single, Auto
10 setups and waveforms can be saved and recalled
internally
CH1 + CH2, CH1 – CH2, CH2 – CH1, CH1 × CH2,
CH1/CH2, CH2/CH1, d/dt (CH1), d/dt (CH2), ∫(CH1)
dt, ∫(CH2)dt, FFT
Yes
Up to 24 measurements
DC, AC
1 MΩ ± 1% ≈ 22 pF ± 3 Pf
2 ns/div to 50 s/div
8-bits
1.75 ns typical
Edge, Glitch, TV, Nth Edge, CAN, LIN
Normal, Single, Auto
10 setups and waveforms can be saved and recalled
internally
Yes
1000.0 mV to 1000.0 V
40 A/400 A 1
1000.00 Ω to 100.00 MΩ
1000.0 nF to 10.000 mF
–40 to 1000 °C
Yes
1V
Yes
1000.0 mV to 1000.0 V
40 A/400 A 1
1000.00 Ω to 100.00 MΩ
1000.0 nF to 10.000 mF
–40 to 1000 °C
Yes
1V
Scope Continued
Waveform math
FFT
Automatic measurements
Coupling
Input impedance
Range
Resolution
Rise time
Trigger types
Trigger modes
Internal scope storage
DMM
True RMS
Voltage AC/DC
Current AC/DC
Resistance
Capacitance
Temperature
Continuity with beeper
Diode test
Data logger
Min/Max/Avg recording
Data logging (requires bundled USB 2.0 full-speed
cable for connection to PC)
Time span
Yes
Yes
Yes
Yes
8 days
8 days
CAT III 600 V 2
Yes
Yes
IP 41
CAT III 600 V 2
Yes
Yes
IP 41
0 to 50 °C (with battery only)
0 to 40 °C (with power adapter)
Yes
<2.5 kgs
3 hours
USB 2.0 full speed host/client port
3 years
183 x 270 x 65 mm
0 to 50 °C (with battery only)
0 to 40 °C (with power adapter)
Yes
<2.5 kgs
3 hours
USB 2.0 full speed host/client port
3 years
183 x 270 x 65 mm
Yes
10 selectable languages
Yes
10 selectable languages
Safety and Regulatory
Over-voltage safety protection
EN/IEC 61010-1:2001 compliance
CSA C22.2 No. 61010-1:2004 compliance
IP rating
General
Operating temperature
Battery (included)
Weight
Battery life
I/O
Warranty
Dimensions (H x W x D)
Special features
Indoor, outdoor, night vision mode
UI language
1
Use U1583B for current measurement
2
10:1 probe for CAT III 600 V
represents key specifications/features
For complete specifications, please refer to data sheet 5990-9523EN
Web Link
www.agilent.com/find/U1600
29
Multi-function Calibrator/Meter
U1401B – Handheld Multi-function Calibrator/Meter
More often than not, the calibration of process control parts requires simultaneous
measurements with a DMM. Carry two tools in one—and calibrate while you measure—
with the Agilent U1401B handheld multi-function calibrator/meter. Now you can travel
light, whether you’re doing calibration for validation, troubleshooting, or service and
maintenance. Slip the robust U1401B in its sturdy carrying case and you’re ready to go.
Features
•
•
•
•
•
50,000-count resolution on dual display
Simultaneous source and measure capabilities
Bipolar voltage and current, square-wave, auto scan and ramp outputs
Full-span DMM measurement and recording functions
Built-in charging capability
Applications with the U1401B Multi-Function Calibrator/Meter
Simultaneous source and measure with just one tool
Commonly used in today’s process control systems are signal conditioners and
loop-powered isolators. These typically
involve high-accuracy signals and demand
periodic calibration to ensure optimum
performance.
Calibration requires sourcing a known
signal into the device and measuring its
output. For instance, calibration of a
loop-powered isolator with 4-20 mA
input/output range involves accurately
simulating a known mA signal into the
isolator and measuring its corresponding
mA output to ensure that it is performing
well within its specifications. Being wellequipped means you need to carry both a
calibrator and digital multimeter (DMM)
as you go about your calibration tasks.
Loop-powered isolator
Zero
In
30
Span
Out
Not so with the U1401B calibrator/meter.
One tool equips you with both sourcing
and measuring capabilities so you no longer need to carry a separate DMM when
you’re away from the bench.
DMM
Built-in pulse signal generator for calibrating flow meter systems
U1401B
Flow meters output pulses with frequencalibrator/meter simulates
cies that are proportional to the rate of
electrical signal generated
by the flow meter
flow of liquid that passes through its bladed
turbine rotor. These pulses are then fed
Adjustable
to a signal conditioner. Calibration of
frequency,
amplitude, duty
the signal conditioner requires injecting
cycle and
known pulse signals into it and checking
pulse width
that the resulting output is what it should be.
Right on site and with the U1401B in
hand, you can conveniently simulate the
flow meter’s output pulses into the signal
conditioner, without needing a separate
function generator.
Signal conditioner converts frequency input
to the equivalent 4-20 mA current output
4-20 mA
Signal
conditioner
Pulses are fed to the
signal conditioner
Magnetic pickup coil
generates electrical pulses
Rotation in
proportion to
rate of flow
Bladed turbine rotor
Liquid
flow
Flow tube
Specifications of the U1401B Multi-function Calibrator/Meter
U1401B
Display
Dual display
Counts
Backlight
Yes
50,000
Yes
Source
Voltage
Current
Square-wave
Auto scan and ramp
Simultaneous operation with MEASURE function
± 15 V
± 25 mA
0.5 Hz to 4.8 kHz, selectable Hz and %
Yes
Yes
Measure
True RMS
Basic DCV accuracy
Auto/Manual ranging
Voltage AC/DC
Current AC/DC
Resistance
Frequency
Temperature
Continuity with beeper
Diode test
4-20 mA, 0 to 20 mA % scale
Simultaneous operation with SOURCE function
AC+DC
0.03% + 5 counts
Yes
250 V
500 mA
50 MΩ
200 kHz
1372 °C, K-type thermocouple
Yes
Yes
Yes
Yes
represents key specifications/features
31
Turbine
flow
meter
Specifications of the U1401B Multi-function Calibrator/Meter Continued
U1401B
Data management
Min/Max/Avg recording
Peak recording
Data hold
Data logging to PC
(requires IR-to-USB cable U5481A for connection to PC)
Yes
Yes
Yes
Yes
Safety and regulatory
Over-voltage safety protection
EN/IEC 61010-1:2001 compliance
CSA C22.2 No. 61010-1:2004 compliance
CAT II 150 V
Yes
Yes
General
Operating temperature
Battery (included)
Battery life
I/O
Warranty
Dimensions (H x W x D)
0 to 40 °C
9.6 V Ni-MH rechargeable
80 hours
IR-USB
3 years
192.0 x 90.0 x 54.0 mm
represents key specifications/features
For complete specifications, please refer to data sheet 5990-3459EN
Web link
www.agilent.com/find/handheld-calibrator-meter
How to ?
Easily Perform Process Control Calibration U1401A
http://cp.literature.agilent.com/litweb/pdf/5990-3932EN.pdf
Capacitance/LCR meters
U1700 Series – Handheld Capacitance/LCR meters
Agilent’s U1730C Series handheld LCR meters allow you to measure at
frequencies as high as 100 kHz—a capability typically found only in
benchtop meters. Get measurements done faster using the one-touch
automatic identification function button which displays component type
and more detailed component analysis such as Z, ESR, and DCR. Ideal for
testing on the go, these LCR meters operate on a battery that lasts up to
16 hours. With the U1730C Series that is built for your convenience, you
can perform quick and basic LCR measurements at an affordable price.
Features
•
•
•
•
•
•
•
20,000 counts resolution
0.2% basic accuracy
Wide LCR ranges with three to five selectable test frequencies (up to 100 kHz for U1733C)
Auto identification (Ai) automatically determines and displays component type and measurements
Detailed component analysis with DCR, ESR, Z, D, Q, and θ functions
Battery life of 16 hours/AC-powered
IR-to-USB connectivity for data logging to PC
32
Applications with the U1700 Series Capacitance/LCR Meters
The U1730C Series handheld is a LCR meter
with a wide range of test frequencies of up
to 100 kHz. It also covers wide measurement parameters including Z, L, C, R,
DCR, ESR as well as D, Q, and Θ for
more detailed component analysis. These
features make the U1730C Series ideal
both in component evaluations on the
production line and for fundamental
impedance testing.
SMD tweezer for testing
surface-mount devices
The optional U1782B SMD tweezer
enables easy testing of surface-mount
devices. The tweezer comes with three
shrouded banana plugs and an extended
reach of 770 mm. The U1700 Series
guard terminal provides your measurements with better noise immunity and
accurate readings.
Tolerance and compare modes for quick component sorting
On the manufacturing floor, components
may come in large batches for quick
sorting to pre-defined specifications.
Tolerance mode in the U1700 Series
lets you zap through sorting of incoming
capacitors, inductors or resistors to 1%,
5%, 10% or 20% tolerance of the
specified reference value.
Additionally, compare mode in the
U1701B capacitance meter allows easy
memory save/recall of up to 25 High/
Low limit settings for convenient Pass/
Fail screening of capacitors. This means
speedier testing due to reduced set-up
time and risk of manual input errors.
Tolerance mode of 1%, 5%, 10% and 20%
are available in capacitance and LCR models.
Compare mode in the U1701B reduces test set-up time for capacitor sorting.
33
Specifications of the U1700 Series Capacitance/LCR Meters
U1701B
U1731C
U1732C
U1733C
Display
Dual display
Yes
Yes
Yes
Yes
11,000
20,000
20,000
20,000
Yes
N/A
Yes
Yes
1000 pF to 199.99 mF
N/A
N/A
N/A
N/A
N/A
1%, 5%, 10%, 20%
25 sets of non-volatile
High/Low limit settings
200 pF to 20 mF
200 µH to 2000 H
2 Ω to 200 MΩ
Yes
Yes
Yes
1%, 5%, 10%, 20%
20 pF to 20 mF
20 µH to 2000 H
2 Ω to 200 MΩ
Yes
Yes
Yes
1%, 5%, 10%, 20%
20 pF to 20 mF
20 µH to 2000 H
2 Ω to 200 MΩ
Yes
Yes
Yes
1%, 5%, 10%, 20%
N/A
N/A
N/A
DC charge/discharge
100 Hz, 120 Hz, 1 kHz
100 Hz, 120 Hz,
1 kHz, 10 kHz
100 Hz, 120 Hz,
1 kHz, 10 kHz, 100 kHz
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0 to 50 °C
Alkaline 9 V
AC power adapter and cord
available as option
80 hours
IR-to-USB
3 years
184 x 87 x 41 mm
–10 to 55 °C, 0 to 80% R.H.
–10 to 55 °C, 0 to 80% R.H.
–10 to 55 °C, 0 to 80% R.H.
Yes
Yes
Yes
16 hours
IR-to-USB
3 years
184 x 87 x 41 mm
16 hours
IR-to-USB
3 years
184 x 87 x 41 mm
16 hours
IR-to-USB
3 years
184 x 87 x 41 mm
Counts
Backlight
Measurements
Capacitance
Inductance
Resistance
Dissipation factor (DF)
Quality factor (QF)
Phase angle (θ) measurement
Tolerance mode
Compare mode
Test method/frequency
Data management
Min/Max/Avg recording
Data hold
Data logging to PC
(requires IR-to-USB cable U5481A
for connection to PC)
Safety and regulatory
EN/IEC 61010-1:2001
compliance
General
Operating temperature
Battery (included)
Battery life
I/O
Warranty
Dimensions (H x W x D)
represents key specifications/features
For complete specifications, please refer to data sheet 5990-7778EN
Web link
www.agilent.com/find/handheldlcr
34
Accessories Compatibility Chart
Handheld
clamp meters
Ordering
number
Handheld
scopes
Handheld DMMs
Hand- Handheld
held calibrator/
meter
scopes
Description
U1211A/
12A/
13A
U1191A/
92A/
93A/
94A
U1231A/
32A/
33A
U1241B U1242B U1251B
U1252B
U1253B U1271A U1272A U1273A U1273AX
U1602B/ U1610/
04B
20A
U1401B
Handheld
capacitance/
LCR meters
U1701B/
U1731C/
32C/33C
Kits
U1161A
U1168A
U1180A
U1580A
Extended test
lead kit
Standard test
lead kit
Thermocopule
adapter+lead kit
DMM terminal
test lead set
×
×
×
×
×
×
×
×
×
×
×
×
×
Probes/leads/clamp
U1162A
Alligator clips
U1163A
SMT grabbers
×
×
U1164A
Fine-tip test
probes
×
U1169A
Test probe leads
×
U1176A
Probe clip light
U1177A
Infrared
(IR)-to-Bluetooth
Adapter
×
×
×
×
×
×
×
U1583B
AC current clamp
×
×
U1781A
Alligator clip
leads
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1782B
SMD tweezer
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U5402A
Yellow test lead
for mA
simulation
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Probes/adapters/leads for temperature measurement
U1179A
IR connectivity
bracket
U1181A
Immersion
temperature
probe
U1182A
U1183A
U1184A
U1185A
U1186A
U1586B
Industrial surface
temperature
probe
Air temperature
probe
Temperature
probe
adapter
J-type
thermocouple
and adapter
K-type
thermocouple
and adapter
×
×
×
(For
U1212A/
13A only)
(For
U1194A
only)
(For U1233A
only)
×
×
×
(For
U1212A/
13A only)
(For
U1194A
only)
(For U1233A
only)
×
×
×
(For
U1212A/
13A only)
(For
U1194A
only)
(For U1233A
only)
×
×
×
(For
U1212A/
13A only)
(For
U1194A
only)
(For U1233A
only)
×
×
×
(For
U1212A/
13A only)
(For
U1194A
only)
(For U1233A
only)
×
×
Temperature
module
= Compatible
×
(For U1233A
only)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
= Not Compatible
35
×
×
×
×
×
×
×
×
×
Accessories Compatibility Chart Continued
Handheld
clamp meters
Ordering
number
Handheld DMMs
Handheld Handheld
scopes
scopes
Handheld
calibrator/
meter
Handheld
capacitance/
LCR meters
U1602B/
04B
U1401B
U1701B/
U1731C/
32C/33C
Description
U1211A/
12A/
13A
U1191A/
U1231A/
92A/
32A/
93A/
33A
94A
U1241B
U1242B
U1251B
U1252B
U1253B
U1271A
U1272A
U1273A U1273AX
U1610/
20A
Probes/clips for scope-only functions
U1554A
Hook clip for
probe tip
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1560A
Scope probe x 1
CAT III 300 V
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1561A
Scope probe x 10
CAT III 600 V
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1562A
Scope probe x 100
CAT III 600 V
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Carrying case/hanging kit
U1171A
Magnetic
hanging kit
×
×
×
×
×
×
U1172A
Transit case
(aluminium-clad)
×
×
×
×
×
×
U1174A
Soft carrying case
×
×
U1175A
Soft carrying case
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1178A
Soft carrying case
×
U1590A
Soft carrying case
(PVC leather)
×
×
×
×
×
×
×
×
×
×
×
×
U1591A
Soft carrying case
×
×
×
×
×
×
×
×
×
×
×
×
×
U5491A
Carrying case (PVC
leather)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Power/cables
U1170A
Battery charger
adapter
U1173A
IR-to-USB cable
U1570A
AC power adapter
and cord
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1571A
Ni-MH battery
pack
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1572A
Li Ion battery pack
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1573A
Desktop charger &
Li Ion battery pack
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1574A
AC/DC adapter
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1575A
Desktop charger
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1577A
USB 2.0 cable
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U1780A
AC power adapter
and cord
×
×
×
×
×
×
×
×
×
×
×
×
×
×
U5481A
IR-to-USB cable
×
×
×
×
×
×
×
×
×
×
×
×
×
×
= Compatible
×
×
= Not Compatible
36
×
Optional Accessories
U1161A Extended Test Lead Kit
U1175A Carrying case
• Extended test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (4-mm tips):
CAT III 1000 V, CAT IV 600 V, 15 A
• Medium-sized alligator clips:
CAT III 1000 V, CAT IV 600 V, 15 A
• 4-mm banana plugs: CAT II 600 V, 10 A
U1162A Alligator clips
• One pair of insulated alligator clips (red and black).
Recommended for use with Agilent standard test leads.
• Rated CAT III 1000 V, CAT IV 600 V, 15 A
• Ideal for the U1210 series handheld clamp meters
• Dimension (H x W x D): 290 x 120 x 85 mm
U1176A LED Probe Clip Light
• 3 " in length
• To be clipped onto test probes to increase visibility
• Comes with one AAA battery
U1177A Infrared (IR)-to-Bluetooth Adapter
U1163A SMT grabbers
• One pair of SMT grabbers (red and black). Recommended
for use with Agilent standard test leads.
• Rated CAT II 300 V, 3 A
• Dimension (H x W x D): 71 x 39 x 37 mm
• Operated by two 1.5 V AAA batteries
• Compatible with U1210 Series Clamp Meters and
all handheld DMMs
U1164A Fine-tip test probes
U1178A Soft carrying case
• One pair of fine-tip test probes (red and black).
Recommended for use with Agilent standard test leads.
• Rated CAT II 300 V, 3 A
• Ideal for the U1190 series handheld clamp meters
• Dimensions (H x W x D): 245 x 120 x 50 mm
U1179A IR connectivity bracket
U1168A Standard test lead kit
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (19-mm tips): CAT II 1000 V, 15 A
• Test probe (4-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A
(highly recommended for CAT IV environment)
• Alligator Clips: CAT III 1000 V, CAT IV 600 V, 15 A
• Fine tip test probes: CAT II 300 V, 3 A
• SMT grabber: CAT II 300 V, 3 A
• Mini grabber (black only): CAT II 300 V, 3 A
U1169A Test probe leads
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (19-mm tips): CAT II 1000 V, 15 A
• Test probe (4-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A
(highly recommended for CAT IV environment)
• Compatible only with the U1240 Series handheld digital
multimeters
• Enables wireless remote connectivity when paired with
the U1177A or to a PC with U1173A
U1180A Thermocouple adapter/lead kit
Includes thermocouple adapter, thermocouple bead J-type
and thermocouple bead K-type.
• T/C adapter J/K-type
• T/C bead J-type: –20 to 200 °C
• T/C bead K-type: –20 to 200 °C
U1181A Immersion temperature probe
•
•
•
•
U1170A Battery charger adapter
• Includes AC power cord based on country
• For use with U1252A/U1253A DMMs
Type-K T/C for use in oil and other liquids
Measurement range: –50 to 700 ºC
Includes adapter U1184A for connection to DMM
Requires module U1186A for connection to scope
U1182A Industrial surface temperature probe
U1171A Magnetic hanging kit
•
•
•
•
• For use with handheld DMMs
Type-K T/C for use on still surfaces
Measurement range: –50 to 400 ºC
Includes adapter U1184A for connection to DMM
Requires module U1186A for connection to scope
U1173A IR-to-USB cable
U1183A Air temperature probe
• For remote control and data logging to PC
• Max. baud rate: 19,200 bits per second
• Compatible with all Agilent HH DMMs
•
•
•
•
U1174A Soft carrying case
The convenient way to carry your DMM and essential
accessories
• Dimension (H x W x D): 9 x 5 x 3”
37
Type-K T/C for use in air and non-caustic gas
Measurement range: –50 to 800 ºC
Includes adapter U1184A for connection to DMM
Requires module U1186A for connection to scope
Optional Accessories
U1184A Temperature probe adapter
U1575A Desktop charger
• Mini-connector-to-banana-plug adapter for use
with DMM
• 2-output 3 A battery charger
• Dimension (H x W x D): 2.30 x 4.89 x 6.89 inches
• For use with U1610A/20A handheld oscilloscope
U1577A – USB 2.0 Cable
(Type-A Plug to Type-A Plug)
U1185A J-type thermocouple and adapter
• T/C adapter J/K-type
• T/C bead J-type: –20 to 200 °C
• For remote control and data logging to PC
U1186A K-type thermocouple and adapter
U1580A DMM terminal test lead set
• T/C adapter J/K-type
• T/C bead K-type: –20 to 200 °C
• Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
• Test probe (4-mm tips): CAT III 1000 V, CAT IV 600 V, 15 A
• Alligator clips: CAT III 1000 V, CAT IV 600 V, 15 A
U1554A Hook clip for probe tip
• Rated CAT II 1000 V, CAT III 600 V
U1583B AC current clamp
U1560A – Scope probe x1 CAT III 300 V
• Dual range: 40 A and 400 A
• Rated CAT III 600 V
• BNC-to-banana-plug adapter provided for use with
handheld DMMs and oscilloscopes
• Include ground alligator clip and hook clip, rated CAT
III 300 V
U1586B Temperature module
• Measures –50 ~ 1000 °C
• K-type bead probe provided for use with DMMs
U1561A – Scope probe x10 CAT III 600 V
• Include ground alligator clip and hook clip, rated CAT
III 600 V
U1590A Soft carrying case
• Dimension (H x W x D): 9.6 x 13.0 x 4.5”
• PVC leather material
• Ideal for the U1602/04B handheld oscilloscope
U1562A – Scope probe x100 CAT III 600 V
• Include ground alligator clip and hook clip, rated CAT
III 600 V
U1591A Soft carrying case
• Dimension (H x W x D): 12.6 x 15.7 x 3.9"
• Soft carrying case with backpack and shoulder strap
• Ideal for the U1610/20A handheld oscilloscope
U1570A AC power adapter
• Includes AC power cord based on country
• For use with U1602/04B handheld
oscilloscopes
U1731P Combo Kit
• 4500 mA, 7.2 V
• For use with U1602/04B handheld oscilloscopes
Includes one U1731C handheld and four accessories:
• U5491A soft carrying case
• U5481A IR-USB cable
• U1780A AC adapter
• U1782B SMD tweezer
U1572A Li Ion battery pack
U1732P Combo Kit
• 4800mAh, 10.8V
• Compatible with U1610A/20A handheld oscilloscope
Includes one U1732C handheld and four accessories:
• U5491A soft carrying case
• U5481A IR-USB cable
• U1780A AC adapter
• U1782B SMD tweezer
U1571A Ni-MH battery pack
U1573A Desktop charger & Li Ion
battery pack
• 4,800 mAh, 10.8 V
• For use with U1610A/20A handheld oscilloscope
U1733P Combo Kit
Includes one U1733C handheld and four accessories:
• U5491A soft carrying case
• U5481A IR-USB cable
• U1780A AC adapter
• U1782B SMD tweezer
U1574A – AC/DC adapter
• Include AC power cord based on country
• For use with U1610A/20A handheld oscilloscope
38
Optional Accessories Continued
U1780A AC power adapter
• Includes AC power cord based on country
• For use with U1700 series handheld capacitance/
LCR meters
U1781A Alligator clip leads
• For use with handheld capacitance and LCR meters
U1782B SMD tweezer
• Measurement Accuracy for Capacitance (Tweezers Open)
<0.7pF, Resistance (Tweezers Short) <0.5Ω, Inductance
(Tweezers Short) <1.2µH
• Guard ends to be connected to guard terminals of meter
for better noise immunity
U5402A Yellow test lead for mA simulation
• For use with handheld multi-function calibrator/meter
U5481A IR-to-USB cable
• For remote control and data logging to PC
• Max. baud rate: 19,200 bits per second
• For use with U1700 series handheld capacitance/LCR meters
and U1401A multi-function calibrator/meter
U5491A Carrying case
• Dimension (H x W x D): 8.9 x 12.2 x 3.1”
• PVC leather material
• Ideal for handheld multi-function calibrator/meter or
instruments of similar size
39
www.agilent.com
www.agilent.com/find/goorange
For other technical literature, promotion information and online product
demos, visit us at:
www.agilent.com/find/clampmeter
www.agilent.com/find/handheldlcr
www.agilent.com/find/handhelddmm
www.agilent.com/find/handheldscope
www.agilent.com/find/handheld-calibrator-meter
myAgilent
myAgilent
www.agilent.com/find/myagilent
A personalized view into the information
most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for
Instrumentation and Test (AXIe) is
an open standard that extends the
AdvancedTCA for general purpose
and semiconductor test. Agilent
is a founding member of the AXIe
consortium.
www.lxistandard.org
LAN eXtensions for Instruments puts
the power of Ethernet and the Web
inside your test systems. Agilent
is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation
(PXI) modular instrumentation
delivers a rugged, PC-based highperformance measurement and
automation system.
Agilent Advantage Services is committed
to your success throughout your equipment’s lifetime. To keep you competitive,
we continually invest in tools and
processes that speed up calibration and
repair and reduce your cost of ownership.
You can also use Infoline Web Services
to manage equipment and services more
effectively. By sharing our measurement
and service expertise, we help you create
the products that change our world.
www.agilent.com/find/advantageservices
www.agilent.com/quality
For more information on Agilent
Technologies’ products, applications or
services, please contact your local Agilent
office. The complete list is available at:
www.agilent.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
(11) 4197 3600
01800 5064 800
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 375 8100
Europe & Middle East
Belgium
32 (0) 2 404 93 40
Denmark
45 45 80 12 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125 €/minute
Germany
Ireland
Israel
Italy
Netherlands
Spain
Sweden
United Kingdom
49 (0) 7031 464 6333
1890 924 204
972-3-9288-504/544
39 02 92 60 8484
31 (0) 20 547 2111
34 (91) 631 3300
0200-88 22 55
44 (0) 118 927 6201
For other unlisted countries:
www.agilent.com/find/contactus
Agilent Channel Partners
Revised: October 11, 2012
www.agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s
measurement expertise and product
breadth, combined with channel
partner convenience.
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2012
Published in USA, November 6, 2012
5989-7340EN
Download PDF