Powerware 5125 UPS family
Features
Protects connected equipment
from common power anomalies
including surges, sags, brownouts,
and over-voltage
Provides more real wattage in less
space with a .9 power factor—
protecting more equipment and
leaving more room for expansion.
Available in two-in-one form factor
(1000-3000 VA) and rackmount
(5000/6000 VA) products
Offers the choice of rackmount
or tower installation—space-saving
2U packaging for 1000-3000 VA,
3U for 5000/6000 VA models—
including batteries
Increases battery life through
Powerware 5125 tower model
1000 to 2200 VA
Powerware 5125 two-in-one
form factor 1000 to 3000 VA
Introducing the expanded
Powerware 5125 family of UPSs
The Powerware® 5125 family of uninterruptible
power systems (UPSs) resolves the five primary
problems with incoming utility power—outages,
sags, surges, brownouts, and over-voltage conditions—and supplies clean, conditioned power to
all connected equipment. It also offers varying
Powerware 5125 rackmount
5000 to 6000 VA
Snapshot
Power Rating: 1000-2200 VA tower models
1000-3000 VA - two-in-one models
(rackmount and tower)
5000-6000 VA rackmount models
Voltage:
200, 208, 220, 230, 240 Vac
Frequency:
50/60 Hz (auto-sensing)
Configuration: tower, two-in-one form factor
or rackmount
microprocessor-controlled
degrees of protection from other problems, such
Advanced Battery Management
as line noise, frequency variation, harmonics, and
Up to 6000 VA of UPS power is packed into three
switching transients.
units (3U) of rack space—a mere 5.25" high,
®
(ABM ) technology
Enables prioritized shutdown of
non-essential equipment during
outages to maximize backup time
for critical devices
Increases uptime with hot-swappable
batteries and electronics, without
interrupting power to connected
including batteries. This space-saving 3U design is
Incorporating more than 40 years of UPS design
experience, Powerware 5125 UPSs deliver power
protection for PC/workstation clusters, enterprise
networking systems, server farms, and data
with a complete suite of power
management software and connectivity options
Provides a two-year limited warranty
with next business day replacement,
you can buy. That means more rack space is
available for other critical equipment, such as
servers, disk arrays, and extra batteries.
center systems—anywhere continuous, clean
power must be provided in a compact package at
In addition to occupying less rack space than
an affordable price.
competing alternatives, Powerware 5125 UPSs
systems (2400–6000 VA models)
Ensures data and system integrity
one of the most power-dense 5000-6000 VA UPSs
deliver significantly more wattage—more power
This proven family of UPSs—which already
included models for 1000-3000 VA—has been
expanded with new 5000 VA and 6000 VA models
that offer space-saving designs and innovative
features at competitive prices to deliver greater
to protected equipment for the same utility
dollar. The new Powerware 5125 5000 VA and
6000 VA models power 30 percent more servers
in 40 percent less space compared to the leading
competitive offering.
return from your IT investment.
The difference is a .9 power factor—a measure of
10-year pro-rated warranty, and
Power more servers in less space
$25,000 load protection guarantee;
Powerware 5125 models in the 1000-3000 VA
optional Gold Plans available (US
range only occupy 2U. For maximum deployment
and Canada*)
flexibility, the standard chassis (available in beach
gray or black) can be deployed as a tower unit or
in a rack.
apparent power versus real power. By delivering
more real output power, the Powerware 5125 can
actually power more servers than another UPS of
equivalent VA rating. This feature applies to twoin-one and rackmount models.
Line-interactive design shields systems from
Add battery modules for even more backup
silent threats
capacity
The line-interactive 5125-series UPSs regulate voltage
Up to four Extended Battery Modules can be added
by boosting input utility voltage up or moderating it
to provide additional battery backup capacity as
down as necessary before allowing it to pass to the
necessary. Batteries are hot-swappable and can be
protected equipment.
replaced at any time without interrupting UPS
And if input voltage varies as much as 20 percent
operation and load protection.
over nominal voltage or 30 percent under—which
Extended Battery Modules are available in three
can easily happen when running on generator
forms: tower models, 2U and 3U rackmount models,
power—the Powerware 5125 accepts this inconsistent
designed to install tightly in tandem with the UPS for
voltage and delivers clean, consistent output.
a clean look that enhances the appearance of the
Unlike typical line-interactive systems, Powerware
5125 UPSs do not switch back and forth to battery
power to accomplish this (which would shorten
battery life and increase battery replacement costs),
and do not send disruptive voltage spikes when
boosting power up to specification.
M®
data center while saving precious space.
Powerware 5125 Battery Runtime Chart (minutes full/half load)
Load VA
Internal
Tower models
1000
5/14
1500
6/17
2200
5/14
Two-in-one (rackmount and tower)
1000
7/19
1500
5/13
2400
7/19
3000
5/15
Rackmount models
5000
7/19
6000
5/15
1 EBM
2 EBMs
3 EBMs
4 EBMs
25/60
33/79
26/60
models
33/68
23/57
35/73
25/61
55/170
63/146
55/170
83/199
92/174
81/198
109/228
120/201
106/224
58/120
49/161
60/124
49/103
82/166
73/172
85/177
69/146
105/214
96/205
110/229
90/190
24/61
19/49
46/106
36/85
67/156
53/125
89/210
71/168
* Up to 4 EBMs can be connected to all models. EBM run times include internal batteries.
Run time chart provides typical information. Battery run times are approximate and may vary
with equipment, configuration, battery age, temperature, etc.
Load Segments feature maximizes battery backup
for critical systems
Data based on tests performed by an independent
battery manufacturer.
Using Powerware LanSafe power management
software, you can independently control "Load
Segments," which are groups of receptacles on the
Extend battery life with Advanced Battery
rear panel of the Powerware 5125 UPS. This feature
Management (ABM®) technology
enables you to manage scheduled shutdowns and
Most UPS manufacturers in the market today offer
sequential startups of protected loads. During a
batteries that are constantly ‘trickle-charged’—a
power outage, you could shut down power to non-
process that degrades the battery’s internal chemical
critical devices (Load Segment 2),
composition, reducing potential battery service life by
thereby extending battery backup time
as much as 50 percent. In contrast, Powerware ABM
available for critical devices (Load
technology uses sophisticated sensing circuitry and an
Segment 1). When the Load Segments
innovative three-stage charging technique that
feature is used with Powerware connec-
increases the useful service life of UPS batteries while
tivity cards, users can remotely re-boot
optimizing battery recharge time.
locked-up network equipment. Simply
The Powerware 5125 provides up to 60 days’ notice
connect to the interface card over the
of the end of useful battery service life, to allow
network, and toggle the password-
ample time to hot-swap batteries without ever having
protected Load Segment controller to
to shut down connected equipment.
get your network back online.
Load Segment 1
with critical
equipment
Powerware 5125 tower
model 1000 to 2200 VA
Load Segment 2
with less critical
equipment
Hot-swappable battery modules when batteries reach the end of their
Connectivity options offer maximum flexibility
useful life, replace battery modules
without powering down connected
Connectivity options are available to suit nearly any communication
equipment (available on all models)
requirement. The standard unit is equipped with a RS-232 serial
communications port and a built-in USB port (5000 and 6000 VA models)
to interface with power management software. You can customize your
UPS by adding any of the following X-slot interface options for other types
Hot-swappable electronic
modules - replace electronics modules without shutting
down connected equipment
(available on 2400 VA to
6000 VA models)
of communications:
ConnectUPS Web/SNMP Interface Card
enables direct control and monitoring in
SNMP-based networks, plus the ability to
monitor UPS status and meters through a
Powerware 5000/6000 VA rackmount model
Web browser (includes built-in switch hub)
Multi-server Card enables up to six serially
Easily service the UPS without interrupting power
to protected systems
LEDs on the front panel of the Powerware 5125
indicate the presence of alarm conditions, battery
utilization, bad or low batteries, site wiring faults, and
incoming utility power, as well as current load levels
relative to UPS capacity.
connected devices of mixed operating systems to be independently managed and
controlled by a single UPS
Relay Interface Card provides dry-contact
interface between the UPS and any relayconnected device, including the IBM®
eServer® iSeries (AS/400) and a variety of
industrial applications
When batteries reach the end of their useful life, or
electronics modules require service, replacement is
easy. With simple access through the front panel,
users can install new battery and electronics modules
without ever powering down connected servers or
removing the unit from the rack.
Environmental Monitoring Probe (EMP)
works with the ConnectUPS Web/SNMP
card, remotely monitoring temperature,
humidity, and the status of two
contacts/sensors, such as smoke detector
and open-door detector
The key is an internal automatic bypass feature
(available on 2400 VA–6000 VA models) that allows
the UPS to continuously provide power to critical
equipment while you’re working on the system. Even
if you pull out the electronics, the UPS keeps doing
its job.
Powerware 5125 6000 VA
rackmount hardwired model
ConnectUPS-X
EMP
Web/SNMP card
Using Powerware’s innovative power management
software, you can securely monitor UPS and battery
performance over your LAN or the Web, establish
prioritized shutdown of network devices and
client/server applications, test all networked UPS
systems from one node, analyze trends and network
conditions, and stay informed of potential power
problems by pager and email.
Gain a new level of confidence
The culmination of 40 years of R&D excellence, the
Powerware 5125 2U and 3U rackmount models
Power management software unifies and
newly expanded Powerware 5125 UPS family delivers
confidence—confidence that your organization’s critical
centralizes UPS management
Every Powerware 5125 UPS comes with a CD that
includes multimedia demonstrations, product data
sheets, and the following power management
electronics are protected by reliable and effective lineinteractive protection, and confidence that Powerware
will be there with you for the long term with warranty
coverage and expert technical support.
software:
Free LanSafe power man-
Powerware offers a comprehensive, two-year limited
agement software for net-
warranty covering parts and labor. For warranty
work shutdown
service on your Powerware 5125, we will ship a
replacement unit via overnight express.
30-day trial version of
Powerware PowerVision®
For added confidence, your Powerware 5125 UPS is
UPS performance analysis
also covered by a 10-year pro-rated warranty and
and monitoring software
$25,000 load protection guarantee.
Powerware LanSafe power management software
gives you control and visibility over all your UPS
systems, using an intuitive, graphical interface and
SNMP (Simple Network Management Protocol).
To find out more, visit our Web site at
www.powerware.com, or contact us at
1-800-356-5794.
Powerware Recommends
Software
Connectivity
> Expansion Chassis
> Powerware
> Connectivity cards:
LanSafe power
ConnectUPS Web/SNMP/xHub
management software
USB
ensures data integrity;
Relay
free updates available
Modbus
Multiserver
Service
> Gold Plan
> Gold Plan Plus
Enhance your power
system maintenance
coverage with Gold Plan
or Gold Plan Plus service
System Solutions
> Extended
Battery
Modules
> Power
Distribution
Units
*See the Two-year Limited Warranty, the ten-year Pro-rated Warranty, and the Load Protection Guarantee for Powerware 5125 Products for details.
Powerware® 5125 Model Selection Guide
Model
Number1
Power Rating Input/Output
(VA/Watt)
Voltage (VAC)2
Input
Connection
Output
Receptacles4
Dimensions
HxWxD (in/mm)
Weight
(lb/kg)
Part Number/
UPC Code
5-15P,
6 ft line cord
5-15P,
6 ft line cord
5-20P,
6 ft line cord
(6) 5-15R
9.45 x 6.38 x 15.79/
240 x 162 x 401
9.84 x 6.38 x 18.39/
250 x 162 x 467
9.84 x 8.07 x 19.41/
250 x 205 x 493
34.3/15.6
05146629-5501/
790341032937
05146632-5501/
790341032968
05146635-5501/
790341032999
Tower Models (North America)
PW 5125 1000
1000/700
120
PW 5125 1500
1440/1050
120
PW 5125 2200
1920/1600
120
PW 5125 2200b
2080/1600
208
IEC-320-15A,
inlet3
(9) IEC-320-10A (C13)
9.84 x 8.07 x 19.41/
250 x 205 x 493
68.3/31.0
05146636-5501/
790341033002
IEC-320-10A,
Inlet3
IEC-320-10A,
Inlet3
IEC-320-10A,
Inlet3
(6) IEC-320-10A (C13)
9.45 x 6.38 x 15.79/
240 x 162 x 401
9.84 x 6.38 x 18.39/
250 x 162 x 467
9.84 x 8.07 x 19.41/
250 x 205 x 493
34.3/15.6
05146630-5501/
790341032944
790341032975/
790341032975
05146637-5501/
790341033019
(6) 5-15R
(6) 5-15R,
(2) 5-20R
50.7/23.0
68.3/31.0
Tower Models (International)
PW 5125 1000i
1000/700
230
PW 5125 1500i
1500/1050
230
PW 5125 2200i
2200/1600
230
(6) IEC-320-10A (C13)
(9) IEC-320-10A (C13)
50.7/23.0
68.3/31.0
5
Two-in-One (Rackmount and Tower) Form Factor Models (North America)
PW 5125 1000 RM
1000/900
120
PW 5125 1500 RM
1440/1340
120
PW 5125 2400 RM
2400/2250
120
PW 5125 3000 RM
2880/2700
120
5-15P,
6 ft line cord
5-15P,
6 ft line cord
L5-30P,
(12’ attached)
L5-30P,
(12’ attached)
(6) 5-15R
3.5 x 17.0 x 19.4/
89 x 432 x 494
3.5 x 17.0 x 19.4/
89 x 432 x 494
3.5 x 19.0 x 24.5/
89 x 483 x 623
3.5 x 19.0 x 24.5/
89 x 483 x 623
(6) 5-15R
(1) L5-30R,
(6) 5-15R
(1) L5-30R,
(6) 5-15R
61.0/27.67
61.0/27.67
89.0/40.40
89.0/40.40
05146666-5501/
790341033033
05146669-5501/
790341033064
05147564-5501/
790341035310
05147152-5501/
790341035273
Two-in-One (Rackmount and Tower) Form Factor Models5 (International)
PW 5125 1000i RM
1000/900
230
PW 5125 1500i RM
1500/1340
230
PW 5125 2400i RM
2400/2250
230
PW 5125 3000g RM
3000/2700
200-240
PW 5125 3000e RM
3000/2700
230
3000/2700
230
PW 5125 3000i RM
Rackmount Models Only
IEC-320-10A,
Inlet3
IEC-320-10A,
Inlet3
IEC-309 16A P,
(12’ attached)
IEC-320-16A,
receptacle
IEC-320-16A,
receptacle
IEC-309 16A P
(12’attached)
(6) IEC-320-10A (C13)
(6) IEC-320-10A (C13)
(1)
(9)
(1)
(9)
(1)
(9)
(1)
(9)
IEC-320-16A
IEC-320-10A
IEC-320-16A
IEC-320-10A
IEC-320-16A
IEC-320-10A
IEC-320-16A
IEC-320-10A
(C19)
(C13)
(C19)
(C13)
(C19)
(C13)
(C19)
(C13)
3.5 x 17.0 x 19.4/
89 x 432 x 494
3.5 x 17.0 x 19.4/
89 x 432 x 494
3.5 x 19.0 x 24.5/
89 x 483 x 623
3.5 x 19.0 x 24.5/
89 x 483 x 623
3.5 x 19.0 x 24.5/
89 x 483 x 623
3.5 x 19.0 x 24.5/
89 x 483 x 623
61.0/27.67
5.25 x 17.50 x 26.0/
133 x 445 x 661
5.25 x 17.50 x 26.0/
133 x 445 x 661
5.25 x 17.50 x 26.0/
133 x 445 x 661
161/73
61.0/27.67
89.0/40.40
89.0/40.40
89.0/40.40
89.0/40.40
05146667-5501/
790341033040
05146670-5501/
790341033071
05147565-5501/
790341035327
05147155-5501/
790341035297
05147641-5501/
790341035921
05147154-5501/
790341035280
6
PW 5125 5000 RM
5000/4500
200/208, 220,
230, 240
L6-30P
L6-30R on short cord,
(2) L6-20 (4) C13
HW, (4)C19, (4)C13
PW 5125 6000 RM HW
6000/5400
200-240
HW (terminal block)
PW 5125 6000i RM
6000/5400
220, 230, 240
IEC309-32A
IEC309-32A on short
cord, (4)C19, (4)C13
161/73
161/73
103003611-5501/
790341043414
103003610-5501/
790341043582
103003612-5501/
790341043421
Optional Extended Battery Modules (EBMs)
For use with PW 5125 24 V EBM
1000 VA tower models only
For use with PW 5125 48 V EBM
1500/2200 VA tower models only
For use with PW 5125 48 V EBM RM
1000/1500 VA RM models only
For use with PW 5125 120 RM
2400/3000 VA RM models only
For use with PW 5125
240 EBM (beach grey)
5000/6000 VA RM models only
For use with PW 5125
240 EBM (black)
5000/6000 VA RM models only
9.84 x 6.38 x 18.66/
250 x 162 x 474
9.84 x 6.38 x 18.66/
250 x 162 x 474
3.5 x 17.0 x 19.4/
89 x 432 x 494
3.5 x 19.0 x 24.5/
89 x 483 x 622
59.5/27.0
05146638-5501/
790341033088
05146639-5501/
790341033095
05147148-5501/
790341033101
05147156-5501/
790341035303
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5.25 x 17.50 x 24.75/
133 x 445 x 629
169/76
103003387-5501/
790341041007
N/A
N/A
N/A
N/A
5.25 x 17.50 x 24.75/
133 x 445 x 629
169/76
103003387-6501/
790341041014
59.5/27.0
65.0/29.5
121.0/54.9
1. 50/60 automatic frequency selection. 2. 120 V models are 110 V, 120 V, 127 V user-selectable. 230 V models are 220 V, 230 V, 240 V user-selectable. 208 V models are 208 V, 220 V, 230 V, 240 V userselectable. 3. Includes (2) each IEC interconnect cables. 4. 1000-1500 VA models are divided into (2) Load Segments (receptacle groups). 2200-3000VA models are divided into (3) Load Segments (receptacle groups). 5000/6000VA models are divided into (2) Load Segments. 5. Unit fits into standard 19-inch racks. Mounting kits are sold separately. 6. 5000/6000 VA models ship with both black and beige
front panel bezels; models include rail kits and mounting hardware; factory installed ConnectUPS Web/SNMP/xHub card available by inserting -5507 for -5501.
Available Options
Order Number
05141562-0021
05146726-5501
05146871-5501
05146875-5501
05146447-5502
05146508-5501
1018460
103002974-5501
103002510-5501
103003637-5501
05146519-001
05146401-5501
Description
4-post rackmount kit (1000-3000 VA rackmount models) fits 19-inch racks
2-post rack mount kit (1000-3000 VA rackmount models) fits 19-inch racks
3-Slot seismic mounting kit (1000/1500 rackmount models only)
5-Slot seismic mounting kit (1000/1500 rackmount models only)
Multi-server card
USB card
Relay card
ConnectUPS Web/SNMP card
Modbus card
Environmental Monitoring Probe (EMP)
Powerpass Distribution Module (1000/1500 rackmount models only)
Power Distribution Unit 250 VA 0U form factor. Side cabinet mount (5000/6000 VA)
Technical Specifications1
Electrical Input
Nominal Voltage2
1000–2200 VA
2400–3000 VA
5000/6000 VA
120, 208 and 230 Vac2
120, 208 and 230 Vac2
200/208, 220, 230 and 240 Vac2
Input Voltage Ranges (for
low voltage: 77-152 V
user-selectable voltages)
high voltage: 154-288 V
Operating Frequency
160-288
50/60 Hz, auto-sensing
Frequency Range
46-54 hz for 50 hz; 56-64 hz for 60 hz
Electrical Output
On Utility Voltage Regulation
-10% to +6% of nominal
On Battery Voltage Regulation
±5% RMS
Voltage Wave Shape (on battery)
sine wave
Output Protection
short circuit protection
Battery
Battery Type
sealed, lead-acid; maintenance free
Battery Runtime
see Battery Run Time table
Battery Replacement
hot-swappable internal batteries and external batteries modules
Recharge Time
<3 hours to 90% usable capacity
Start-On-Battery
allows start of UPS without utility input
General
Electrical Power Module Replcmnt
no
yes, hot-swap
Diagnostics
UPS Bypass
no bypass
internal bypass
Transfer Time
4ms typical, 6ms max
Dimensions and Weights
Overload (normal operation)
yes, hot-swap
full system self-test on power up
see Model Selection Guide
110% overload, shutdown after 3 minutes
150% overload, shut down 10 cycles
100-102 % indefinite, 103-112% 2 minutes and
> 112% 12 line cycles
Communications
User Interface
front control panel
Audible Alarms
for various UPS alarm conditions, including: on battery, low battery, overload, UPS fault
Network Transient Protector
UL 497 A, in/out jacks RJ45 (high voltage models
network protection) & RJ11 (low voltage models modem protection)
REPO Port
No
meets NEC code 645-11 intent and UL requirements
Communication Ports
see Communications Slot
native USB and serial port
Communication Slot
RS-232 single serial module (standard)
options available, see options chart
Web/SNMPxHub card factory
installed; other options also available
Cable
6-foot communications cable included
Power Management Software
Powerware Software Suite CD-ROM (bundled with UPS)
Environmental
Safety Certifications
EMC Compliance
UL; cUL; NOM; C-Tick; CE marking
FCC Part 15, EN50091-2, Class A
for 2.2 KVA and RM; Class B for 1000
and 1500 VA tower models
UL; cUL; NOM; C-Tick; CE marking
TUV/VDE, GS
FCC Part 15, EN50091-2, Class A
Operating Temperature
0 to 40ºC (32 to 104ºF)
10°C to 40°C
Storage Temperature
-15 to 50ºC (5 to 122ºF)
-25°C to 55°C
Relative Humidity
0% to 95% non-condensing
Lightning & Surge Protection
ANSI/IEEE C62.41 (IEEE 587), IEC61000-4-5
Surge Energy Rating
Audible Noise
high-energy 6500 A peak
less than 40 dBA typical
Altitude
less than 45 dBA typical
3000m (10,000 ft) without derating
1. Specifications are subject to change without notice due to continuing product improvement programs. 2. See Model Selection Guide for user-selectable voltages.
Powerware®, ABM® technology and PowerVision® are registered trademarks of Powerware Corporation©2004. IBM® and eServer® are trademarks of IBM Corporation.
Powerware
WORLDWIDE HEADQUARTERS
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
or 919.872.3020
www.powerware.com
CANADA
Ontario: 416.798.0112
5125FXA
Revision 06/04
Reprint 06/04
EUROPE/MIDDLE EAST/AFRICA
Denmark: 45.3686.7910
Finland: 358.94.52.661
France: 33.1.6012.7400
Germany: 49.7841.666.0
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
ASIA PACIFIC
Australia/NZ: 61.2.9878.5000
China: 86.21.6361.5599
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.2649.9414 to 18
Singapore/SEA: 65.6829.8888
LATIN AMERICA
Argentina: 54.11.4343.6323
Brazil: 55.11.3616.8500
México: 52.55.9171.7777
Download PDF