Schools Network Foundation Deployment Guide

Schools Network Foundation Deployment Guide
Schools Network Foundation Deployment
Guide
Last Updated: October 18, 2009
Schools Network Foundation Deployment Guide
SBA
Building Unified Schools Network Infrastructure 1
Hierarchical Network Design with Collapsed Core
District Office Network Design 1
EtherChannel 2
Resilient Distributed System 2
Access-Layer Edge Services 3
Access-Layer Design 3
School Site Design 4
School Collapsed Core Design 4
School Access-Layer Design 4
Device Resiliency
1
Deploying Schools Foundation Services 4
Implementing EtherChannel in School Network 4
EtherChannel Load Balancing 5
Implementing Dynamic Routing 6
Designing End-to-End EIGRP Routing Domain 6
Deploying A Multi-Layer Access Network 9
Spanning-Tree in Multilayer Network 9
Other STP Toolkit Consideration 10
Access Network Design Options 10
Implementing Layer 2 Trunk 11
Unidirectional Link Detection 12
Deploying a Routed-Access Network 13
Implementing EIGRP Routing in Access-Distribution Block
Building EIGRP Network Boundary 14
EIGRP Adjacency Protection 16
Tuning EIGRP Protocol Timers 16
Building a Resilient Network 16
Redundant Hardware Components 17
Redundant Power System 17
Redundant Network Connectivity 17
Redundant Control-Plane 18
Operational Resiliency Strategy 19
Deploying Resiliency in the Schools Network
Network Resiliency 19
19
20
WAN Design 24
Service Deployed in the Design 24
Bandwidth Capacity Planning 25
IP Address Aggregation 26
Routing for WAN Connections 26
WAN QoS Design 27
WAN QoS Policy at School Site 28
Core Distribution Integration 28
Large School Design 29
Core/Distribution Virtual Interfaces 29
Example Port Channel Configuration 29
Example Catalyst 4500Modular Switch Port Channel Configuration
Example 2960 Port Channel Configuration 29
WLC Connection 30
NAC CAS Connection 30
Core/Distribution NAC CAS Configuration 30
SRST Connection 30
Sample Configuration 30
WAN Connection 30
WAN Port Sample Configuration-Core/Distribution 30
13
Small School Design 31
Core/Distribution Virtual Interfaces 31
Example Port Channel Configuration 31
WLC Connection 31
Example Catalyst 3750 Stack Port Channel Configuration
NAC CAS Connection 32
Core/Distribution NAC CAS Configuration 32
SRST Connection 32
WAN Connection 33
District Office Design 33
Metro Ethernet Connection Configuration
ASA Connection 35
Services Block Connection 35
33
32
29
Schools Network Foundation Deployment Guide
Core/Distribution Virtual Interfaces
WLC Connection 37
NAC CAS Connection 37
SRST Connection 37
NTP
38
SBA
36
Schools Design Principles and Foundational Technologies
• Single Fabric—Multi Services
• Differentiated Services
• Layer 2 and Layer 3 Access
This document provides design guidance to build a highly resilient, manageable and
cost-effective school network which provides a solid in foundation for seamless
integration and operation of applications and network services. The network has been
specifically designed to meet the challenges of the education environment.
This document consist of three major section:
• Schools Network Infrastructure
• Core Distribution Integration
• District Office Integration
The first section focuses upon the networking technology that is the foundation of the
SRA, such as Layer 2 Networking, IP Routing, and QoS. The following two section
specifically address the integration of core components into the the foundation, for
example the connection of components such as ISR Routers, Wireless LAN Controllers,
and Services Blocks to the network.
Hierarchical Network Design with Collapsed Core
A three-tier heirarchical design maximizes performance, network availability, and the
ability to scale the network design. Most school campus' do not grow significantly larger
over time, and most school campus' are small enough to be well served by a two-tier
hierarchical design, where the Core and Distribution layers are collapsed into one layer.
The primary motivation for the collapsed core design is reducing network cost, while
maintaining most of the benefits of the three-tier hierarchical model.
Deploying a collapsed core network results in the Distribution layer and Core layer
functions being implemented in a single device. The collapsed Core/Distribution device
must provide:
• High speed physical and logical paths connecting to the network
• Layer-2 aggregation and demarcation point
• Define routing and network access policies
• Intelligent network services—QoS, Network virtualization, etc.
Note If the District Office or a School Campus has multiple buildings, and is expected
to grow over time, then implementing the three-tier hierarchical model is a better
choice.
Figure 1 illustrates a sample network diagram for a single building school district office.
Figure 1
Collapsed Core School District Office Network Design
Access
Building Unified Schools Network Infrastructure
Cisco has many years of experience developing high performance, highly available, multi
service networks. The key to developing a robust design is applying a proven
methodology. The following design principles were applied to develop the School SRA
network architecture:
• Hierarchy
• Modularity
• Resiliency
• Flexibility
The Unified Schools Network is designed to be highly available, and cost effective, while
delivering capabilities necessary to enable advanced services, such as IP telephony,
video, security, wireless LANs. The network design includes the following key features;
• Heirarchichal design with collapsed Core
• Quality of Service to enure real time data (telephony, video) are given higher priority
• Application of Resilient design principles
• Multicast
• Routed Access
• Redundancy
Floor 6 –
Social Science and Health
Internet
Floor 5 –
Arts and Technology
Floor 4 –
History and Geography
Floor 3 –
Library and Communication Center
Floor 2 –
Administration and Data Center
WAN
Distribution/
Core
PSTN
227531
This document describes the Schools Service Ready Architecture network design, which
is a well designed and tested network architecture that is flexible, and cost effective to
support a wide range of educational services. Key features of the Schools SRA include:
• High Availability
SBA
District Office Network Design
If the District Office has multiple buildings, or the District Office site is expected to grow
significantly over time; then implementing the 3 tier hierarchical model is a good choice.
For smaller District Office sites which are unlikely to grow significantly, the collapsed core
model is more cost effective. The School Service Ready Architecture utilizes the
collapsed core network design in the District Office.
Schools Design Principles and Foundational Technologies
SBA
The Collapsed Core network may be deployed with redundant core/distibution router, or
consolidated core/distribution router. See Figure 2.
Collapsed core district office school network models
Campus Deployment Design – 1
Internet
WAN
PSTN
Campus Deployment Design – 2
Internet
WAN
PSTN
Figure 3
Optimized control and forwarding paths with EtherChannel
Control-Plane
Internet
Distribution/Core
PSTN
Internet
WAN
PSTN
Distribution/Core
Access
227532
Access
WAN
Forwarding-Path
The redundant design is more complex, since all of the core/distribution functions must
be implemented on two routers in a complimentary fashion. To learn more about the
redundant designs, refer to High Availability School Recovery Analysis Design Guide
http://www.cisco.com/en/US/docs/solutions/Enterprise/Campus/HA_recovery_DG/ca
mpusRecovery.html
The School SRA District Office is designed with a consolidated core/distribution router to
maximize performance, while keeping costs affordable. With this design, the default
behavior of layer-2 and layer-3 nework control protocols is to create a redundant view
between two systems. The core router builds a ECMP routing topology which results in
symetric forwarding paths beyond the District Office.
Default layer-2 configuration eliminates the need for FHRP,. This simplifies the network
operation, since there is no need to configure or tune FHRP protocols. Since this design
employs point-to-point links between the collapsed core and peer devices, the solution
is to tune the network to enable a single control plane, to improve forwarding efficienty and
resource utilization. The recommendation is to aggregate all physical ports into a single
logical channel-group. This logical aggregated Ethernet bundle interface is known as
EtherChannel .
EtherChannel
EtherChannel provides inverse-multiplexing of multiple ports into a single logical port to
a single neighbor. This technique increases bandwidth, link efficiency, and resiliency.
EtherChannel technology operates on the MAC layer. Upper layer protocols require a
single instance to operate over the logical interface. EtherChannel provides efficient
network operation and graceful recovery to higher layer protocols during bundle port
failure and restoration.
Single Layer 3
IGP adjacency
STP Primary
Root
STP Primary
Root
Single Layer 3
IGP adjacency
Single Layer 2
STP operation
VLAN
10
VLAN
20
VLAN
30
Layer 2 Trunk Port
Layer 3 Rounded Port
Standby Firewall Port
VLAN
10
VLAN
20
Bi-directional Traffic Port
VLAN
30
227537
Figure 2
EtherChannel helps improve the overall network stability and availability. Failure of
individual physical link will cause network topology recomputation, restoration, and may
be rerouted. Such process requires CPU interruption that could impact the overall
application performance. EtherChannel significantly simplifies the network response to
a individual link failure. If an individual link in EtherChannel fails, the interface will not
trigger any network topology changes. All underlying hardware changes remain
transparent to higher-layer protocols, thus minimizing impact to network and application
performance, and improving network convergence. Figure 3 illustrates how enabling
EtherChannel in Layer-2 and Layer-3 network simplifies control-plane and
forwarding-plane.
Resilient Distributed System
The consolidated core/distribution layer may become a single-point-of-failure (SPOF) in
the network. A software upgrade or a route-processor failure may cause network outage
for minutes.
The school SRA uses the Cisco Catalyst 4500 with next-generation Supervisor-6E in the
consolidated core/distribution layer. It is choosen for it's price performance, and the high
availability features within the device. The Cisco Catalyst 4500 switch supports
redundant supervisor engines and provides Stateful Switchover (SSO) and Non-Stop
Forwarding (NSF) capabilities. SSO ensures the L2 and L3 protocol state-machines and
network forwarding entries on the standby supervisor engine are maintained, and can
quickly assume control-plane responsibilities and gracefully restore the control-plane in
the event of a primary supervisor failure. While the control-plane is gracefully recovering,
the NSF function continues to switch traffic in hardware.
Schools Design Principles and Foundational Technologies
SBA
Access-Layer Edge Services
Table 1
The access layer is the first tier or edge of the network. It is the layer where end devices
(PCs, printers, cameras, etc.) attach to the school network. It is also the layer where devices
that extend the network out one more level are attached; IP phones and wireless access
points (APs) are examples of devices that extend the connectivity out from the access
switch. The wide variety of devices that can connect and the various services and
dynamic configuration mechanisms required, make the access layer the most
feature-rich layer of the school network. Figure 4 illustrates a district office network
deployment with various types of trusted and untrusted endpoints. .
Service Requirements
Service Features
Energy Efficient Services
Power over Ethernet, EnergyWise, Energy efficient systems
Management Services
Auto-SmartPort Macro, Cisco Network Assistant
Figure 4
Access-Layer Trust Boundary and Network Control Services
Access-layer Services and Capabilities
The access layer provides the intelligent demarcation between the network infrastructure
and the computing devices that use the infrastructure. It provides network edge security,
QoS, and policy trust boundary. It is the first point of negotiation between the network
infrastructure and the end devices seeking access to the network.
Design details, explaining how to select the features needed for a given deployment, and
how to implement the features is provided in Schools Access Layer Features chapter,
Core
Access-Layer Design
School SRA is designed with 2 to 4 uplink ports for each access switch, providing
link-failure protection, the Schools SRA Acces Network supports a Hybrid Access Layer
of either a flat, segmented and/or Layer 3 as required by the school. (these Access layer
options are discussed in more detail later in this document) .
Distribution/Core
For mission critical endpoints, School SRA employs the Cisco StackWise or StackWise
Plus solution in the access. It is designed to physically stack and interconnect multiple
Layer-2 or Layer-3 switches using special cables. Stacking multiple switches into a logical
ring creates a single unified and resilient access-layer network topology. The Cisco
Catalyst 2975 StackWise can be deployed in Layer-2 network domain and the Cisco
Catalyst 3750-E StackWise or StackWise Plus is deployed for routed access
implementations. See Figure 5.
Network
Control
Services
Access
Trust
Boundary
Figure 5
Resilient, Scalable and Efficient Access-Layer Network Design
IP
Wired/Wireless
Trusted/Untrusted
Endpoints
227538
Core
Table 1
Distribution/Core
Access-layer Services and Capabilities
Service Requirements
Service Features
Discovery and Configuration
Services
802.1AF, CDP, LLDP, LLDP-MED
Integrated Security Services
IBNS (802.1X), CISF – Port-Security, DHCP Snooping, DAI and IPSG
Network Identity and Access
802.1X, MAB, Web-Auth
Application Recognition Services
QoS marking, policing, queueing, deep packet inspection NBAR
Intelligent Network Control Services PVST+, Rapid PVST+, EIGRP, OSPF, DTP, PAgP/LACP, UDLD, FlexLink,
Portfast, UplinkFast, BackboneFast, LoopGuard, BPDUGuard, Port
Security, RootGuard
Link Protection –
Resilient Logical Link
Access
Distributed Layer 2 EtherChannel Uplink
Cross-StackWise Ring link
Node Protection –
Catalyst 3750-E/2975
StackWise Ring
227540
Table 3 examples of the types of services and capabilities that need to be defined and
supported in the access layer of the network.
Schools Design Principles and Foundational Technologies
SBA
School Site Design
The School Service Ready Architecture includes two school site designs. One for larger
schools, and another for medium to smaller schools. The typical school site is a single
building with a limited popluation which makes the collapsed core network design a
suitable choice.
School Collapsed Core Design
The key criteria to consider when designing a school network are the network size,
bandwidth capacity and high-availability requirements. The School Service Ready
Architecture includes two models; one for smaller schools, and another for larger schools.
Both designs offer high capacity, performance and availability. illustrates the two school
network design models. See Figure 6.
Figure 6
Collapsed core school network models
School Campus Design Model – 1
WAN
School Campus Design Model – 2
PSTN
WAN
forwarding. If the master switch fails, another switch will quickly assume the control plane
'master' function. This results in a cost effective, high performance, scalable solution, with
built in resliiency.
• Performance —Provides wire-rate network connection to access switches
• Scalable—May deploy up to 9 switches in a stack to aggregate a reasonble number
of access switches
• High Availability—Stack provides a virtual switch, with distributed control plane,
delivering subsecond system failure recovery times
The Cisco 3750-E StackWise Plus delivers high performance routing and switching
capability and robust IOS feature support. The control-plane and forwarding paths
functions for the Cisco 3750-E StackWise Plus in the collapsed core network design
remain the same. For more information about the Cisco 3750-E StackWise architecture,
refer to the following URL:
http://www.cisco.com/en/US/partner/prod/collateral/switches/ps5718/ps5023/prod_w
hite_paper09186a00801b096a_ps7077_Products_White_Paper.html
School Access-Layer Design
PSTN
The Access-layer network design at the school site is the same as at the district office.
The same devices are available, and the same design choices may be deployed to
achieve a high performance, secure and resilient access layer. To simplify the overall
system design, and network operations, it is recommended to use consistent design and
platform selections in the access-layer role, at the district office and school sites. This will
allow a common configuration template and simplify operations and troubleshooting
procedures.
Cisco
Catalyst
4500-E
Distribution/Core
Cisco Catalyst
3750-E
Stackwise
Distribution/Core
Deploying Schools Foundation Services
The two-tier hierarchical design delivers a reliable and resilient, scalable, and
manageable foundation network design. This subsection provides design and
deployment guidelines for the school core layer, and access-distribution block.
Access
Access
VLAN
10
VLAN
20
Layer 2 Trunk Port
Layer 3 Rounded Port
VLAN
30
VLAN
30
Implementing EtherChannel in School Network
Layer 2 Trunk Port
Layer 3 Rounded Port
227541
VLAN
10
VLAN
20
The Access - Distribution block, as described in the "School Network Design" section on
page 20, uses a combination of Layer-2 and Layer-3 switching to provide a balance of
policy and access controls, availability, and flexibility in subnet allocation and VLAN
usage. Deployment guidelines are provided to implement multi-layer, and routed access
designs in the access-distribution block.
Design Model-1 is for a larger school site. The network design is the same as the District
Office network design, with the same performance capabilities, scalability options, and
high availability features.
Design Model-2 is for a medium to small school site. The primary difference is the use of
the Cisco Catalyst 3750-E Stack Wise Plus switch in the collapsed core/distribution layer.
The 3750-E Stack Wise Plus deploys up to nine 3750-E switches in a ring topology as a
single virtual switch. Each chassis replicates the control functions, and provides packet
Etherchannel is used throughout the network design, and the implementation guidelines
are the same for multi-layer, and routed-access models, and in the WAN edge design. As
recommended in the "EtherChannel Fundamentals" section on page 14, there should be
single logical point-to-point EtherChannel deployed between collapsed core and
access-layer. The EtherChannel configuration on each end of the link in the
access-distribution block must be consistent to prevent a link bundling problem.
EtherChannels use link bundling protocols to dynamically bundle physical interfaces into
a logical interface.
The following are the benefits of building EtherChannel in dynamic mode:
• Ensure link aggregation parameters consistency and compatibility between
switches.
Schools Design Principles and Foundational Technologies
• Ensure compliance with aggregation requirements.
• Dynamically react to runtime changes and failures on local and remote Etherchannel
systems
• Detect and remove unidirectional links and multi-drop connections from the
Etherchannel bundle.
EtherChannels can be deployed in dynamic or static modes. Both EtherChannel modes
can coexist in a single system; however, the protocols (PagP, LACP) can not interoperate
with each other.
• Cisco proprietary link aggregation-Cisco's implementation of Port Aggregation
group Protocol (PAgP) is supported on all the Cisco Catalyst platforms. The PAgP
protocol is not supported when the Cisco Catalyst 2975 or 3750 Series switches are
deployed in StackWise mode.
• EEE 802.3ad link aggregation-Link Aggregation Control Protocol (LACP) is based on
IEEE 802.3ad specification to operate in vendor-independent network environment.
LACP link bundling protocol is developed with same goal as Cisco's PAgP. Cisco
Catalyst switches in StackWise mode must use LACP to dynamically bundle.
See Figure 7.
Figure 7
Implementing EtherChannel in District Office School Network
WAN
SBA
cr24-4507-DO(config-if)#
cr24-4507-DO(config-if)#interface Port-channel11
cr24-4507-DO(config-if)# description Connected to cr24-2960-DO
cr24-4507-DO(config-if)# switchport
cr24-4507-DO(config-if)#
cr24-4507-DO(config-if)#interface Port-channel16
cr24-4507-DO(config-if)# description Connected to cr25-3750s-DO
cr24-4507-DO(config-if)# switchport
cr24-4507-DO(config-if)#
cr24-4507-DO(config-if)#interface range Gig 3/3 , Gig 4/3
cr24-4507-DO(config-if-range)# description Connected to cr24-3750ME-DO
cr24-4507-DO(config-if-range)# channel-protocol pagp
cr24-4507-DO(config-if-range)# channel-group 1 mode desirable
cr24-4507-DO(config-if-range)#
cr24-4507-DO(config-if-range)#interface range Gig 1/1 , Gig 2/1
cr24-4507-DO(config-if-range)# description Connected to cr24-2960-DO
cr24-4507-DO(config-if-range)# channel-protocol pagp
cr24-4507-DO(config-if-range)# channel-group 11 mode desirable
cr24-4507-DO(config-if-range)#
cr24-4507-DO(config-if-range)#interface range Gig 1/6 , Gig 2/6
cr24-4507-DO(config-if-range)#description Connected to cr26-3750s-DO
cr24-4507-DO(config-if-range)# channel-protocol lacp
cr24-4507-DO(config-if-range)# channel-group 16 mode active
Enabling EtherChannel on each switch endpoint will automatically form a logical
connection and can be verified using following CLI command:
PSTN
cr24-4507-DO#show etherchannel summary | inc Po
cr24-3750ME-do
cr26-2851-do
Group
Port-channel
1
Po1(RU)
Protocol
PAgP
Ports
Gi3/3(P)
Gi4/3(P)
11
Po11(SU)
PAgP
Gi1/1(P)
Gi2/1(P)
16
Po16(SU)
LACP
Gi1/6(P)
Gi2/6(P)
EtherChannel Load Balancing
EtherChannel load-sharing is based on a polymorphic algorithm. On per protocol basis,
load sharing is done based on source XOR destination address or port from Layer 2 to 4
header and ports. For higher granularity and optimal utilization of each member-link port,
an EtherChannel can intelligently load-share egress traffic using different algorithms.
cr24-4507-DO
Distribution/Core
Access
cr24-2960-do
cr25-3750s-do
L2 EtherChannel
L3 EtherChannel
227542
cr24-3560r-do
The following sample configuration shows how to build Layer-2 and Layer-3 EtherChannel
configuration and bundling physical ports into appropriate logical EtherChannel-group:
cr24-4507-DO#config t
Enter configuration commands, one per line. End with CNTL/Z.
cr24-4507-DO(config)#interface Port-channel1
cr24-4507-DO(config-if)# description Connected to cr24-3750ME-DO
EtherChannel load-balancing mechanisms function on a per-system basis. By default,
EtherChannel will use the hash computation algorithm. The network administrator can
globally configure the load balancing mechanism. In Cisco Catalyst platforms,
EtherChannel load balancing is performed in hardware and it cannot perform
per-packet-based load balancing among different member links within EtherChannel.
Bandwidth utilization of each member-link may not be equal in default load balancing
mode. The Ether Channel load balancing method should be changed to source and
destination IP address based throughout the district office and school network Tuning the
load-balancing to source-and-destination IP address allows for statistically-superior
load-distribution. When loads are balanced in this manner, packets belonging to a single
flow will retain their packet order. See Figure 8.
Schools Design Principles and Foundational Technologies
Figure 8
Efficient address allocation - hierarchical addressing enables efficient use of address
space, since groups are contiguous.
EtherChannel Load-Balance Method
WAN
SBA
• Improves routing efficienty—Using contiguous ip addresses enables efficient route
summarization. Route summarization simplifies the routing database, and
computations during topology changes. This reduces the nework bandwidth used
by the routing protocol, and improves routing protocol performance by reducing
network convergence time.
• Improves system performance—Hierarchical, contiguous ip addressing reduces
router memory usage by eliminating dis-contiguous and non-summarized route
entries. It saves on CPU cycles needed to compute the routing database during
topology changes. This contributes to a more stable routing network, and simplifies
the task of network operations and management.
PSTN
Edge
Cisco IOS supports many Interior Gateway Protocols (IGP), including EIGRP and OSPF,
either of which are suitable for large network deployments. While OSPF is capable of
greater scale, it is also more complex, and hence more difficult to configure, operate and
manage. The Schools Service Ready Architecture is designed and validated using EIGRP,
since it is a stable, high performance, efficient protocol, which is simple to implement and
manage. The same design principles apply whether using EIGRP or OSPF.
Distribution/Core
Designing End-to-End EIGRP Routing Domain
227543
Access
The following output provides sample configuration guideline for changing the default
port-channel load-balance setting to source-destination-ip based. Aside from Layer-2 or
Layer-3 EtherChannel mode, similar configuration must be applied on each system in the
access-distribution block and WAN edge.
cr24-4507-DO(config)#port-channel load-balance src-dst-ip
cr24-4507-DO#show etherchannel load-balance
EtherChannel Load-Balancing Configuration:
src-dst-ip
EtherChannel Load-Balancing Addresses Used Per-Protocol:
Non-IP: Source XOR Destination MAC address
IPv4: Source XOR Destination IP address
IPv6: Source XOR Destination IP address
Implementing Dynamic Routing
This section provides implementation and best practice guidelines for deploying the
core-layer in both the district office and school site. Proper design of the core network
layer ensures reachability, transparency and availability. This section focuses on building
a unicast routing topology.
Enabling routing in the school network is a simple task. However, the network physical
layout must be carefully planned and designed to ensure flexible, stable and efficient
routing. Developing a hierarchical network addressing scheme enables a stable, efficient
and scalable design.
EIGRP is a balanced hybrid routing protocol that builds neighbor adjacency and a flat
routing topology on a per-autonomous-system (AS) basis. The LAN/WAN infrastructure of
School Service Ready Architecture should be deployed in a single EIGRP AS to prevent
route redistribution, loops, and other problems that may occur due to misconfiguration.
See Figure 9.
Schools Design Principles and Foundational Technologies
Figure 9
End-to-End EIGRP Routing Design in School Architecture
GRP AS – 100
School
SBA
cr24-4507-DO(config-if)# description Connected to cr24_ASA_Inside_Port
cr24-4507-DO(config-if)# ip address 10.125.33.9 255.255.255.0
EIGRP AS – 100
cr24-4507-DO(config)#router eigrp 100
cr24-4507-DO(config-router)# no auto-summary
cr24-4507-DO(config-router)# eigrp router-id 10.125.100.1
cr24-4507-DO(config-router)# network 10.125.0.0 0.0.255.255
cr24-4507-DO#show ip eigrp neighbor port-channel 13
EIGRP-IPv4:(100) neighbors for process 100
H
Address
Interface
Hold Uptime
(sec)
1
10.125.33.10Vl200111d00h
1
200 0 171
0
10.125.32.7Po2161d02h
1
200 0 304
2
10.125.32.5Po1141d02h
2
200 0 25038
EIGRP AS – 100
WAN
SRTT
RTO
(ms)
Q Seq
Cnt Num
PSTN
EIGRP Adjacency Protection
District Office
7544
EIGRP AS – 100
Implementing EIGRP Routing
Implementing summarization in the EIGRP routing process automatically enables EIGRP
routing process on each interface that is summarized. By default, the router transmits and
accept EIGRP hello messages from remote device to form an adjacency on all EIGRP
enabled interfaces. This behavior needs to be modified to ensure a secure, efficient and
stable routing design.
• System efficiency—There is no need to send EIGRP hellos on an interface where
there is no trusted EIGRP neighbor. In a large network, sending EIGRP hello
messages periodically to such interfaces consumes unnecessary CPU resource.
EIGRP route processing should only be enabled on interfaces where trusted network
devices are connected. All other interfaces can be suppressed in passive mode. The
following configuration shows how to automatically disable EIGRP processing on all
the Layer 3 interfaces and only enable on the trusted interface. This design principle
must be applied on each EIGRP router, including distribution and core routers:
The district office is the central hub in the network. Each school site is connected to the
district office over the WAN infrastructure. The district office network includes the Internet
gateway and provides access to the central data-center. Since both the school sites, and
district office networks use the collapsed core design, the routing configuration of the
core routers is the same..
cr24-4507-DO(config)#router eigrp 100
cr24-4507-DO(config-router)# network 10.125.0.0 0.0.255.255
cr24-4507-DO(config-router)# passive-interface default
cr24-4507-DO(config-router)# no passive-interface Port-channel1
cr24-4507-DO(config-router)# no passive-interface Port-channel2
cr24-4507-DO(config-router)# no passive-interface Vlan200
The following is a sample configuration to enable EIGRP routing process at the edge of the
district office collapsed core network. EIGRP is enabled in the school site network with
the same configuration:
cr24-3560r-DO#show ip eigrp interface
EIGRP-IPv4:(100) interfaces for process 100
cr24-4507-DO(config)#interface Loopback0
cr24-4507-DO(config-if)# ip address 10.125.100.1 255.255.255.255
cr24-4507-DO(config-if)#interface Port-channel1
cr24-4507-DO(config-if)# description Connected to cr24-3750ME-DO
cr24-4507-DO(config-if)#no switchport
cr24-4507-DO(config-if)# ip address 10.125.32.4 255.255.255.254
cr24-4507-DO(config-if)#interface Port-channel2
cr24-4507-DO(config-if)# description Connected to cr24-2851-DO
cr24-4507-DO(config-if)#no switchport
cr24-4507-DO(config-if)# ip address 10.125.32.6 255.255.255.254
cr24-4507-DO(config)#interface Vlan200
Xmit
Interface
Vl2001
Po1 1
Po2 1
Peers
0/0 1
0/0 2
0/0 4
Un/Reliable
0/1
50
0/1
50
0/1
50
Queue
SRTT
Mean
Pacing Time
Multicast Pending
Un/Reliable
Flow Timer Routes
0
0
0
cr24-4507-DO#show ip protocols | inc Passive|Vlan
Passive Interface(s):
Vlan1
Vlan101
Vlan102
Vlan103
Vlan104
Schools Design Principles and Foundational Technologies
SBA
• Network Security—Sending unnecessary EIGRP Hello messages opens a security
vulnerability in two ways. An attacker can detect EIGRP operation and send flood of
EIGRP hello messages to destabilize the network. Or an attacker could establish a
"fake" EIGRP adjacency and advertise a best metric default-route into the network to
black hole and compromise all critical traffic. Each EIGRP system should implement
MD5 authentication, and each EIGRP neighbor should validate MD5 authentication is
enabled on adjacent systems . This provides a secure method of transmitting and
receiving routing information between devices in the network. Following is a sample
configuration to enable EIGRP neighbor authentication using MD5:
– -Distribution
Route Aggregator and Summary Route Advertisement Direction
Aggregator
Aggregator
cr24-4507-DO(config-keychain)# key 1
cr24-4507-DO(config-keychain-key)#
Figure 10
WAN
key-string <password>
cr24-4507-DO(config)#interface Port-channel1
cr24-4507-DO(config-if)# description Connected to cr24-3750ME-DO
Aggregator
cr24-4507-DO(config-if)# ip authentication mode eigrp 100 md5
cr24-4507-DO(config-if)# ip authentication key-chain eigrp 100
eigrp-key
Aggregator
– WAN Aggregation
cr24-3750ME-DO(config)#key chain eigrp-key
cr24-3750ME -DO(config-keychain)# key 1
key-string <password>
cr24-3750ME -DO(config)#interface Port-channel1
cr24-3750ME -DO(config-if)# description Connected to cr24-4507-DO
cr24-3750ME -DO(config-if)# ip authentication mode eigrp 100 md5
cr24-3750ME -DO(config-if)# ip authentication key-chain eigrp 100
eigrp-key
• System Stability—As mentioned in Table 8, EIGRP allows network adminstrator to
summarize multiple individual and contiguous networks into a single summarized
network before advertising to neighbors. Route summarization improves
performance, stability, and convergence times, and it makes the network easier to
manage operate and troubleshoot. EIGRP provides the flexibility to summarize at any
point in the network. Proper design requires determining which routers will serve as
Aggregators,and advertise summarized network information to peers. Routers which
connect multiple access devices, or connect to the WAN edge should be made
Aggregators. Figure 17 provides an example Schools SRA network with route
aggregator devices identified with the direction of route summarization illustrated.
227545
cr24-3750ME -DO(config-keychain-key)#
The following sample configuration shows EIGRP route summarization. In this example,
the entire access-layer network is summarized into a single classless network and
advertised to the WAN edge, the ASA firewall and the PSTN gateway.
• Distribution
cr24-4507-DO(config)#interface Port-channel1
cr24-4507-DO(config-if)# description Connected to cr24-3750ME-DO
cr24-4507-DO(config-if)# ip summary-address eigrp 100 10.125.0.0 255.255.0.0
cr24-4507-DO(config-if)#interface Port-channel2
cr24-4507-DO(config-if)# description Connected to cr24-2851-DO
cr24-4507-DO(config-if)# ip summary-address eigrp 100 10.125.0.0 255.255.0.0
cr24-4507-DO(config-if)#interface Vlan200
cr24-4507-DO(config-if)# description Connected to cr24_ASA_Inside_Port
cr24-4507-DO(config-if)# ip summary-address eigrp 100 10.125.0.0 255.255.0.0
cr24-4507-DO#show ip protocols | inc Address|10.125.0.0
Address Family Protocol EIGRP-IPv4:(100)
Address Summarization:
10.125.0.0/16 for Port-channel1, Vlan200, Port-channel2
• WAN Aggregation
Verifying district office EIGRP summarized route status at WAN aggregation layer as
follows:
cr24-3750ME-DO#show ip route 10.125.0.0 255.255.0.0
Routing entry for 10.125.0.0/16
Schools Design Principles and Foundational Technologies
Tuning EIGRP Protocol Timers
EIGRP uses Hello messages to form adjacencies and determine if neighbors are alive.
EIGRP adjacency is declared down if it fails to receive Hello messages within the Hold
down timer interval. All the prefixes discovered from a dead neighbor are removed from
the routing table. By default, EIGRP transmits a Hello message every 5 seconds to notify
neighbors that it is still alive. The EIGRP hold-down timer gets reset each time the router
receives a EIGRP Hello message. Default EIGRP adjacency Hold-down timer is 15
seconds.
Lowering EIGRP hello and hold-down timer intervals improves network convergence
times (ie time to detect and respond to an outage). For Schools SRA design it is
recommended to use the default EIGRP Hello and Hold timer values for the following
reasons:
• EtherChannel Benefits—EIGRP operates over the Layer-3 EtherChannel. In the event
of a single member-link failure condition, layer 2 will respond more quickly than the
routing protocol, and switchover traffic from the impacted link to an alternate member
link. EIGRP routing is not impacted by individual link member and no change in the
routing table is required. Thus reducing the EIGRP timers will not result in quicker
convergence, and may adversely impact system stability.
• High-Availability—The Cisco Catalyst 4500, 37xx (non-Stack Wise) and 35xx series
Layer 3 switches support Stateful-Switch Over (SSO) which enables a backup
supervisor to gracefully assume the active role while maintaining adjacency with
neighbors, during a supervisor failure condition. The backup supervisor requires
sufficient time to detect a failure and initiate graceful recovery with neighbors.
Implementing aggressive timers may abruptly terminate adjacency and cause
network outage before a stateful switch over is accomplished. Thus, default EIGRP
Hello and Hold timers are recommended on Cisco Catalyst 4500, 37xx
(non-Stackwise) and 35xx Series Layer-3 platforms.
Over the years, the STP protocols have evolved into the following versions:
• Per-VLAN Spanning Tree Plus (PVST+)—Provides a separate 802.1D STP for each
active VLAN in the network.
• EEE 802.1w-Rapid PVST+—Provides an instance of RSTP (802.1w) per VLAN. It is
easy to implement, proven in large scale networks that support up to 3000 logical
ports and greatly improves network restoration time.
• IEEE 802.1s MST—Provides up to 16 instances of RSTP (802.1w) and combines many
VLANS with the same physical and logical topology into a common RSTP instance.
Following is the example configuration to enable STP protocol in multi-layer network:
Distribution
cr24-4507-DO(config)#spanning-tree mode rapid-pvst
cr24-4507-DO#show spanning-tree summary | inc mode
Switch is in rapid-pvst mode
Access-Layer Switch
cr24-2960-DO(config)#spanning-tree mode rapid-pvst
Default STP parameters optimize the network for packet forwarding. Best practice design
includes hardening STP parameters in the access and distribution switch to protect
against STP misconfiguration, or malicious user by deploying spanning-tree toolkit in the
access-distribution block. See Figure 18.
Figure 11
Figure 18Hardening Spanning-Tree Toolkit in Multi-Layer Network
Spanning-Tree
Root Switch
Distribution/Core
Root-Guard
Deploying A Multi-Layer Access Network
Multilayer design is one of the two access-distribution block designs included in the
Schools Service Ready Architecture. This section provides implementation and best
practices guidelines the multi-layer design. The deployment and configuration
guidelines for the multi-layer access-distribution block are the same for both district
office and school site networks.
Access
BPDU-Guard
Edge-Port
Layer 2 Trunk Port
227546
Known via "eigrp 100", distance 90, metric 1792, type internal
Redistributing via eigrp 100
Last update from 10.125.32.4 on Port-channel1, 1d04h ago
Routing Descriptor Blocks:
* 10.125.32.4, from 10.125.32.4, 1d04h ago, via Port-channel1
Route metric is 1792, traffic share count is 1
Total delay is 20 microseconds, minimum bandwidth is 2000000 Kbit
Reliability 255/255, minimum MTU 1500 bytes
Loading 1/255, Hops 1
SBA
Spanning-Tree in Multilayer Network
Spanning Tree (STP) is a Layer-2 protocol that prevents logical loops in switched networks
with redundant links. The Schochool SRA design uses Etherchannel (point-to-point
logical Layer-2 bundle) connection between access-layer and distribution switch which
inherently simplifies the STP topology and operation. In this design, the STP operation is
done on a logical port, therefore, it will be assigned automatically in forwarding state.
The following is the configuration deploys spanning-tree toolkit in the access-distribution
block:
Schools Design Principles and Foundational Technologies
SBA
Distribution
cr24-4507-DO(config)#spanning-tree vlan 1-4094 root primary
cr24-4507-DO(config)#interface range Gig 1/1 - 2 , Gig 2/1 - 2
Multi-Layer – Flat Network
Distribution/Core
cr24-4507-DO(config)#spanning-tree guard root
VLAN
10
Admin
cr26-2975-DO(config)#interface GigabitEthernet1/0/1
cr26-2975-DO(config-if)#description CONNECTED TO UNTRUSTED-PC
VLAN
10
Library
VLAN
10
Arts
227547
Access
Access
cr26-2975-DO(config-if)#spanning-tree bpduguard enable
A flat multi-layer network deployment introduces the following challenges:
Other STP Toolkit Consideration
When the access-distribution block multi-layer design is deployed using the
recommended best practices, it automatically minimizes the need for deploying the
following additional spanning-tree toolkit technologies:
• UplinkFast—UplinkFast feature improves the network convergence time by providing
direct access to the root switch link failure. UplinkFast is not necessary in this design,
because there is no alternate STP path and RSTP protocol natively includes rapid
recovery mechanism.
• BackBone Fast—BackboneFast provides rapid convergence from indirect Layer-2
link failures in a redundant distribution switch configuration. This is feature is not
necessary for the same reason as stated for UplinkFast.
• LoopGuard—LoopGuard protects Layer-2 networks from loops that occur due to any
malfunction that prevents normal BPDU forwarding. A STP loop is created when a
blocking port in a redundant topology erroneously transitions to the forwarding state.
This usually happens because one of the ports in a physically redundant topology
(not necessarily the blocking port) stopped receiving BPDUs. Because there is single
point-to-point STP forwarding port in this design, enabling Loopguard does not
provide any additional benefit. UDLD protocol must be implemented to prevent STP
loop that may occur in the network due to network malfunction, mis-wiring, etc.
Access Network Design Options
VLAN assignment can have a significant impact on network performance and stability.
There are three basic ways to assign VLANs within the access-distribution block.
• Scalability—Spanning the same VLAN in different access-layer switches will create
a large Layer-2 broadcast domain that dynamically discovers and populates MAC
address entries for endpoints that may not need to communicate. In a large network,
this may become a scalability issue (ie memory required to hold large CAM table)
• Performance—In a large network, spanning a large number of broadcast domains
will impact the performance of all network devices in the access-distribution block,
because the switch will have to process many more broadcast packets such as ARP
• Security—The flat muli layer design widens the fault domain which increases
possible attacks to a larger number of users.The number of users is not necessarily
due to the number switches spanned and applications during DoS or viruses attack.
Segmented Logical Network Design
Best practice design includes identifying meainingful groups within the user community,
and assigning a unique VLAN to each group. These groups may be departments, user
groups, or any other logical grouping of users. Enabling a unique VLAN for each group will
segment the network and build a logical network structure. .All network communication
between groups will pass through the routing and forwarding policies defined at the
distribution layer. See Figure 13.
Figure 13
Multi-Layer Segmented Network Design
Multi-Layer – Segmented Network
Distribution/Core
Flat Logical Network Design
Figure 12
Multi-Layer Flat Network Design
Access
VLAN
10
Admin
VLAN
20
Library
VLAN
30
Arts
227548
Spanning a single VLAN across multiple access-layer switches is much simpler with a
single collapsed core-distribution device versus a design with redundant distribution
devices. The flat multi-layer design has a single VLAN across multiple access devices, as
shown in Figure 12.
Schools Design Principles and Foundational Technologies
A Segmented VLAN design is the solution to the challenges described in the flat network
design. VLAN segmentation improves the scalability, performance, and security of the
network.
Hybrid Logical Network Design
The Segmented logical network design improves scalability, performance and security,
and addresses the challenges of a flat network design. In real world deployments, there is
usually a need for some users or applications to communicate with all users (eg system
administrator). The Hybrid network design is the segmented design, with the addition of
a exceptional VLAN which spans the entire access-distribution block. See Figure 14.
Figure 14
Multi-Layer Hybrid Network Design
SBA
cr24-4507-DO(config-vlan)#name cr24-3560-Library-Dept
cr24-4507-DO(config-vlan)#vlan 30
cr24-4507-DO(config-vlan)#name cr24-2960-Arts-Dept
• Access
Set VTP domain name and change the mode to the transparent mode as follows:
cr24-3750-DO(config)#vtp domain District-Office
cr24-3750-DO(config)#vtp mode transparent
cr24-3750-DO(config)#vlan 10
Multi-Layer – Hybrid Network
cr24-3750-DO(config-vlan)#name cr24-3750-Admin-Dept
Implementing Layer 2 Trunk
In a typical network design, a single access switch will have more than one VLAN, for
example a Data VLAN and a Voice VLAN. The network connection between Distribution
and Access device is a trunk. VLAN's tag their traffic to maintain separation between
VLANS across the trunk. By default on Cisco Catalyst switches, the native VLAN on each
layer 2 trunk port is VLAN 1, and cannot be disabled or removed from VLAN database.
The native VLAN remains active on all access switches layer 2 ports.
Distribution/Core
Access
Library
VLAN
20
Arts
VLAN
30
VLAN 900
227549
Admin
VLAN
10
Cisco recommends the segmented VLAN network design and optionally hybrid network
for centralized users or applications that requires distributed function across the
access-layer network.
Following are the sample VLAN configuration steps in the access and the distribution
layer switches:
• Distribution
VLAN Trunking Protocol (VTP) is a Cisco proprietary Layer -messaging protocol that
manages the addition, deletion, and renaming of VLANs on a network-wide basis.
Cisco's VTP simplifies administration in a switched network. VTP can be configured
in three modes: server, client, and transparent. Set the VTP domain name and change
the mode to the transparent mode as follows:
cr24-4507-DO(config)#vtp domain District-Office
cr24-4507-DO(config)#vtp mode transparent
cr24-4507-DO(config)#vlan 10
cr24-4507-DO(config-vlan)#name cr24-3750-Admin-Dept
cr24-4507-DO(config-vlan)#vlan 20
There are two choices for encapsulating the tagged VLAN traffic on the trunk: IEEE 802.1Q
or Cisco ISL. It is recommended to implement trunk encapsulation in static mode instead
of negotiating mode, to improve the rapid link bring-up performance. Not all Cisco
Catalyst platforms support ISL encapsulation; therefore IEEE 802.1Q is recommended,
and validated in the access and distribution switches.
Enabling the layer-2 trunk on a port-channel, automatically enables communication for all
of the active VLANs between the access and distribution. This means an access-switch
which has implemented, for example, VLANs 10 to 15, will receive flood traffic destined for
VLANs 20 to 25, which are implemented on another access switch.. RPVST +, using logical
ports, operates on a per-VLAN basis to load balance traffic. In a large network, it is
important to limit traffic on layer 2 trunk ports to only the assigned VLANS, to ensure
efficient and secure network performance. Allowing only assigned VLANs on a trunk port
automatically filters rest.
The default native VLAN must be properly configured to avoid several security risks Attack, worm and virus or data theft.. Any malicious traffic originated in VLAN 1 will span
across the access-layer network. With a VLAN-hopping attack it is possible to attack a
system which does not reside in VLAN 1. Best practice to mitigate this security risk is to
implement a unused and unique VLAN ID as a native VLAN on the Layer-2 trunk between
the access and distribution switch. For example, configure VLAN 802 in the access-switch
and in the distribution switch. Then change the default native VLAN setting in both the
switches. Thereafter, VLAN 802 must not be used anywhere for any purpose in the same
access-distribution block.
Following is the configuration example to implement Layer-2 trunk, filter VLAN list and
configure the native-VLAN to prevent attacks on port channel interface. When the
following configurations are applied on port-channel interface (i.e., Port-Channel 11), they
are automatically inherited on each bundled member-link (i.e., Gig1/1 and Gig2/1):
Schools Design Principles and Foundational Technologies
SBA
Distribution
cr24-4507-DO(config)#vlan 802
cr24-4507-DO(config-vlan)#name Admin-Hopping-VLAN
cr24-4507-DO(config)#interface Port-channel 11
cr24-4507-DO(config-if)# description Connected to cr24-3750-DO
cr24-4507-DO(config-if)# switchport
cr24-4507-DO(config-if)# switchport mode trunk
cr24-4507-DO(config-if)# switchport trunk allowed vlan 101-110,900
cr24-4507-DO(config-if)# switchport trunk native vlan 802
cr24-4507-DO#show interface port-channel 11 trunk
auto-negotiation and UDLD are enabled, Layer 1 and Layer 2 detection works together to
prevent physical and logical unidirectional connections and the malfunctioning of other
protocols.
Copper media ports use Ethernet link pulse as a link monitoring tool and are not
susceptible to unidirectional link problems. Because one-way communication is possible
in fiber-optic environments, mismatched transmit/receive pairs can cause a link up/up
condition even though bidirectional upper-layer protocol communication has not been
established. When such physical connection errors occur, it can cause loops or traffic
black holes. UDLD functions transparently on Layer 2 or Layer 3 physical ports. UDLD
operates in one of two modes:
• Normal mode—If bidirectional UDLD protocol state information times out; it is
assumed there is no-fault in the network, and no further action is taken. The port state
for UDLD is marked as undetermined. The port behaves according to its STP state.
• Aggressive mode—If bidirectionalUDLD protocol state information times out,, UDLD
will attempt to reestablish the state of the port, if it detects the link on the port is
operational. Failure to reestablish communication with UDLD neighbor will force the
port into the err-disable state. That must be manually recovered by user or the switch
can be configured for auto recovery within specified interval of time.
Port
Mode
Encapsulation
Status
Native vlan
Po11
on
802.1q
trunking
802
Port
Vlans allowed on trunk
Po11
101-110,900
Port
Vlans allowed and active in management domain
cr24-4507-DO(config)#interface range Gig 1/2 , Gig 2/2
Po11
101-110,900
cr24-4507-DO(config-int)#udld port
Port
Vlans in spanning tree forwarding state and not pruned
cr24-4507-DO#show udld neighbor
Po11
101-110,900
PortDevice Name
Following is the configuration example to implement UDLD protocol:
Distribution
------
Access-switch
Device ID
----------------
Gi1/2
FOC1318Y06V
Gi2/2
FOC1318Y06J
Port IDNeighbor State
------------ -------- --------------
1
Gi1/0/49Bidirectional
1
Gi3/0/49Bidirectional
cr24-3750-DO(config)#vlan 802
cr24-3750-DO(config-vlan)#name Admin-Hopping-VLAN
Access
cr24-3750-DO(config)#interface Port-channel 1
cr24-3750-DO(config-if)# description Connected to cr24-4507-DO
cr26-2975-DO(config)#interface Gig 1/0/49 , Gig 3/0/49
cr24-3750-DO(config-if)# switchport
cr26-2975-DO(config-if)#description Connected to cr24-4507-DO
cr24-3750-DO(config-if)# switchport mode trunk
cr26-2975-DO(config-if)#udld port
cr24-3750-DO(config-if)# switchport trunk allowed vlan 101-110,900
cr24-3750-DO(config-if)# switchport trunk native vlan 802
cr26-2975-DO#show udld neighbor
PortDevice Name
Device ID
Port IDNeighbor State
Unidirectional Link Detection
------
UDLD is a Layer 2 protocol that works with the Layer 1 features to determine the physical
status of a link. At Layer 1, auto-negotiation takes care of physical signaling and fault
detection. UDLD performs tasks that auto-negotiation cannot perform, such as detecting
the identity of neighbors and shutting down misconnected ports. When both
Gi1/0/49 FOX1216G8LT
1
Gi1/2
Bidirectional
Gi3/0/49 FOX1216G8LT
1
Gi2/2
Bidirectional
----------------
------------ -------- --------------
Schools Design Principles and Foundational Technologies
SBA
Deploying a Routed-Access Network
Figure 16
Forwarding entry development in multi-tier network
This section provides implementation and best practices guidelines to deploy
routed-access in the access-distribution block. The routed access design moves the
boundary between Layer 2 and Layer 3 from the distribution layer to the access layer as
shown in Figure 15.
Control Function in Multi-Layer and Routed-Access Network Design
Distribution/Core
Distribution/Core
MAC
ARP
Route
Routing
Route
Routing
Layer 3
Distribution/Core
Layer 3
Distribution/Core
Access
Access
MAC
Admin
VLAN
10
STP
Routing
Arts
VLAN
30
Multi-Layer Network
Layer 2
Access
Library
VLAN
20
MAC
ARP
Route
Admin
VLAN
10
Library
VLAN
20
Arts
VLAN
30
Routed-Access Network
Access
Layer 2
Library
VLAN
20
Arts
VLAN
30
Multi-Layer Network
Admin
VLAN
10
Library
VLAN
20
Arts
VLAN
30
Routed-Access Network
227550
Admin
VLAN
10
Routing in the access-layer simplifies configuration, optimizes distribution performance,
and improves end-to-end troubleshooting tools. Implementing routing in the access-layer
replaces Layer-2 trunk configuration with single point-to-point Layer-3 interface in
distributon layer. Placing Layer-3 function one tier down on access-switches, changes the
multilayer network topology and forwarding path. Implementing Layer-3 function in the
access-switch does not require a physical or logical link reconfiguration; the same
EtherChannel in access-distribution block can be used.
At the network edge, Layer-3 access-switches provides an IP gateway and become the
Layer-2 demarcation point to locally connected endpoints that could be logically
segmented into multiple VLANs. Following are the benefits of implementing
routed-access in the access-distribution block:
• Eliminates the need to implement STP and the STP toolkit in the distribution layer. As
a best practice, STP toolkit must be hardened at the access-layer.
• Shrinks the Layer-2 fault domain, which minimizes the number of endpoints affected
by a DoS/DDoS attack.
• Improves Layer-3 uplink bandwidth efficiency by suppressing Layer-2 broadcasts at
the access edge port
• Improves performance by reducing resource utilization in collapsed
core-distribution layer. In a large multilayer network, the aggregation layer may
consume more CPU cycles due to the large number of MAC and ARP discovery and
processing and storing required for each end-station. Routed-access reduces the
load of this layer 2 processing and storage in the distribution layer, by moving the load
to Layer-3 access-switches. Figure 16 illustrates where Layer-2 and Layer-3
forwarding entry processing and storage takes plance when access-distribution
block is implemented as multi-layer versus routed-access network.
227551
Figure 15
While the routed access design is appropriate for many school networks it is not suitable
for all environments. Routed access does not allow a VLAN to span multiple access
switches. Refer to following URL for detailed design guidance for the routed access
distribution block design:
http://www.cisco.com/en/US/docs/solutions/Enterprise/Campus/routed-ex.html
Implementing EIGRP Routing in Access-Distribution Block
The School Service Ready Architecture uses EIGRP routing protocol, and all the devices
in the LAN and WAN sub-networks are deployed in a single AS. This subsection focuses
on implementing EIGRP in the access-distribution block. All the deployment and
configuration guidelines in this section are the same for deploying in the district office or
school site network.
Following is the example configuration to enable basic EIGRP routing in the distribution
layer and in the access layer:
Distribution
cr24-4507-DO(config)#interface Port-channel13
cr24-4507-DO(config-if)# description Connected to cr24-3560r-DO
cr24-4507-DO(config-if)#no switchport
cr24-4507-DO(config-if)# ip address 10.125.32.0 255.255.255.254
cr24-4507-DO(config)#router eigrp 100
cr24-4507-DO(config-router)# no auto-summary
cr24-4507-DO(config-router)# eigrp router-id 10.125.100.1
cr24-4507-DO(config-router)# network 10.125.0.0 0.0.255.255
cr24-4507-DO#show ip eigrp neighbor port-channel 13
EIGRP-IPv4:(100) neighbors for process 100
H
Address
Interface
Hold Uptime
SRTT
(sec)
(ms)
3
10.125.32.1
Po13
14 00:02:14
2
RTO
Q
Seq
Cnt Num
200
0 385
Schools Design Principles and Foundational Technologies
SBA
Access
Figure 17
EIGRP Query Path with and without Stub Implementation
EIGRP Query Path without Stub
cr24-3560r-DO(config)#interface Loopback0
cr24-3560r-DO(config-if)# ip address 10.125.100.4 255.255.255.255
cr24-3560r-DO(config-if)#
cr24-3560r-DO(config-if)#interface Port-channel1
cr24-3560r-DO(config-if)# description Connected to cr24-4507-DO
cr24-3560r-DO(config-if)# no switchport
cr24-3560r-DO(config-if)# ip address 10.125.32.1 255.255.255.254
10.100.1.0/24
EIGRP Query Path with Stub
10.100.1.0/24
cr24-3560r-DO(config)#ip routing
cr24-3560r-DO(config)#router eigrp 100
cr24-3560r-DO(config-router)# no auto-summary
cr24-3560r-DO(config-router)# eigrp router-id 10.125.100.4
cr24-3560r-DO(config-router)# network 10.125.0.0 0.0.255.255
EIRGP
Stub
Q
Admin
VLAN
10
Seq
Cnt Num
200
0
Library
VLAN
20
Arts
VLAN
30
Admin
VLAN
10
Routed-Access Network
Library
VLAN
20
Arts
VLAN
30
Routed-Access Network
227552
cr24-3560r-DO#show ip eigrp neighbor port-channel 1
EIGRP-IPv4:(100) neighbors for process 100
H
Address
Interface
Hold
Uptime
SRTT
RTO
(sec)
(ms)
0
10.125.32.0
Po1
13
00:10:00
1
176
Building EIGRP Network Boundary
EIGRP stub router in Layer-3 access-switch can announce routes to a distribution-layer
router with great flexibility.
EIGRP creates and maintains a single flat routing network topology between EIGRP peers.
Building a single routing domain enables complete network visibility and reach ability
between all of the elements within the network.(access, distribution, core, data center,
WAN, etc )
In a tiered design, the access layer always has a single physical or logical forwarding path
to the distribution layer. The access switch will build a forwarding topology pointing to
same distribution switch as a single Layer-3 next-hop. Since the distribution switch
provides a gateway function to the access switch, the routing design can be optimized
with the following two techniques to improve performance and network convergence in
the access-distribution block:
• Deploy Layer 3 access-switch in EIGRP stub mode
EIGRP stub router can be deployed to announce routes dynamically discovered or
statically configured. Best practice design is to deploy EIGRP stub router to announce
locally learned routes to aggregation layer.
• Summarize network view to Layer-3 access-switch for intelligent routing function
Deploy Layer 3 Access-Switch in EIGRP Stub Mode
The Layer-3 access switch can be deployed to announce itself as a stub router that acts
as a non-transit router and does not connect any other Layer-3 stub or non-stub routers.
Announcing itself as a non-transit stub Layer-3 router is one way to notify the distribution
router that it should not include the Layer-3 access switch in the EIGRP topology
recomputation process. This optimized recomputation process will prevent unnecessary
EIGRP network queries, which reduces network traffic, and simplifies the route
computation. As illustrated in Figure 17, implementing EIGRP stub function in the access
switches, greatly reduces the number of EIGRP network queries.
Following is the example configuration to enable EIGRP stub routing in the Layer-3
access-switch, no configuration changes are required in distribution system:
Access
cr24-3560r-DO(config)#router eigrp 100
cr24-3560r-DO(config-router)#eigrp stub connected
cr24-3560r-DO#show eigrp protocols detailed
Address Family Protocol EIGRP-IPv4:(100)
EIGRP metric weight K1=1, K2=0, K3=1, K4=0, K5=0
EIGRP maximum hopcount 100
EIGRP maximum metric variance 1
EIGRP NSF-aware route hold timer is 240
EIGRP stub, connected
Topologies : 0(base)
Distribution
cr24-4507-DO#show ip eigrp neighbors detail port-channel 13
EIGRP-IPv4:(100) neighbors for process 100
H
Address
Interface
Hold Uptime
SRTT
(sec)
(ms)
1
10.125.32.1
Po13
13 00:19:19
16
Version 12.2/3.0, Retrans: 0, Retries: 0, Prefixes: 11
Topology-ids from peer - 0
Stub Peer Advertising ( CONNECTED ) Routes
Suppressing queries
RTO
Q Seq
Cnt Num
200 0 410
Schools Design Principles and Foundational Technologies
Enabling the EIGRP stub function on the access switch does not change the distribution
router behavior of forwarding the full EIGRP topology table. The Distribution router must
be configured to advertise summarized routes that do not compromise end-to-end reach
ability, and help access switches maintain minimal routing information. In a network with a
well designed IP addressing scheme, the aggregation system can advertise summarized
routes in a classless address configuration, that reduce individual network
advertisements, improve network scalability and network convergence. The,distribution
router must have full network topology information to ensure efficient reachability paths.
Hence it is recommended to summarize at the distribution router, and not summarize at
the access-layer.
Route summarization must be implemented on the distribution layer of district office and
each school site network. This includes devices such as the WAN aggregation in the
district office. The distribution router must advertise the following summarized network
information to Layer 3 access-switch:
Figure 18
End-to-End Routed-Access Network
10.127.0.0/21
10.125.0.0/16
10.126.0.0/16
10.127.0.0/16
0.0.0.0/0
School
• Default Network—When Layer 3 access-switch receives unknown destination traffic
from the edge that does not match any of the above mentioned summarized
networks, then it is sent to the distribution router to make a forwarding decision. The
distribution router performs a forwarding table lookup and may forward to
appropriate path or black hole the traffic. In a typical school environment, a default
route is announced by an Internet edge system, to forward all internet traffic.
Distribution router must propagate this default route to the Layer 3 access-switch.
Figure 18 illustrates a summarized EIGRP network advertisement, by route aggregation
system, that provides end-to-end internal and external network reachability.
10.125.0.0/16
10.126.0.0/16
10.127.0.0/16
0.0.0.0/0
Internet
WAN
School
10.126.0.0/16
0.0.0.0/0
• Local Network—Distribution router can be implemented in hybrid
access-distribution configuration that interconnects several multi-layer or
routed-access enabled access-layer switches. Independent of route origination
source (connected or dynamic route) and network size within the access-distribution
block, the distribution router in district office and school site network must advertise
a single, concise and summarized Layer 3 network to each Layer 3 access-switch
and to core devices.
• Remote Network—Summarized network will be propagated dynamically across the
network. Single summarization of all remote networks may be advertised to local
Layer 3 access-switchs, since it improves bandwidth efficiency. During a network
outage, Layer 3 access-switch may drop traffic at the network edge instead of
transmitting it to the distribution router to black hole traffic.
• WAN Network—Announcing a single summarized WAN network provides flexibility
to troubleshoot and verify network availability.
10.127.112.0/21
District Office
10.125.0.0/16
10.126.0.0/16
10.127.0.0/16
0.0.0.0/0
10.125.0.0/16
227553
Summarizing the Routed Networks
SBA
Following is configuration example to deploy summarized and filtered Layer-3 network
information to Layer-3 access-switch.
Distribution
interface Port-channel13
description Connected to cr24-3560r-DO
dampening
ip address 10.125.32.0 255.255.255.254
ip authentication mode eigrp 100 md5
ip authentication key-chain eigrp 100 eigrp-key
ip summary-address eigrp 100 10.125.0.0 255.255.0.0 5
load-interval 30
carrier-delay msec 0
!
!configure ACL and route-map to allow summarized route advertisement to Layer 3
accessswitch
!
access-list 1 permit 0.0.0.0
access-list 1 permit 10.126.0.0
access-list 1 permit 10.127.0.0
access-list 1 permit 10.125.0.0
!
route-map EIGRP_STUB_ROUTES permit 10
match ip address 1
!
Schools Design Principles and Foundational Technologies
SBA
• Network Security—EIGRP adjacency between distribution and Layer-3
access-switch must be secured. Following is the example configuration to enable
EIGRP neighbor authentication using MD5:
router eigrp 100
distribute-list route-map EIGRP_STUB_ROUTES out Port-channel13
cr24-4507-DO#show ip protocols | inc Outgoing|filtered
Outgoing update filter list for all interfaces is not set
Port-channel13 filtered by
Distribution
cr24-4507-DO(config)#key chain eigrp-key
cr24-4507-DO(config-keychain)# key 1
cr24-4507-DO(config-keychain-key)#
key-string <password>
Access
cr24-3560r-DO#show ip route eigrp
10.0.0.0/8 is variably subnetted, 15 subnets, 4 masks
D
10.126.0.0/16 [90/3328] via 10.125.32.0, 01:37:21, Port-channel1
D
10.127.0.0/16 [90/3584] via 10.125.32.0, 01:37:21, Port-channel1
D
10.125.0.0/16 [90/1792] via 10.125.32.0, 01:34:29, Port-channel1
D*EX 0.0.0.0/0 [170/515072] via 10.125.32.0, 00:03:15, Port-channel1
cr24-3560r-DO#
EIGRP Adjacency Protection
EIGRP adjacency protection guidelines discussed earlier for the core network, apply
equally to routed access in the access-distribution block. ,The two challenges, system
efficiency, and network security also apply equally to the routed access design, and the
same solution is applied.
• System efficiency—EIGRP hello transmission must be blocked on an interface
where there are no trusted EIGRP neighbors, to reduce CPU utilization and prevent
network attacks. EIGRP routing process should only be enabled on interfaces where
trusted school devices are connected. All other interfaces can be suppressed in
passive mode.
Following is the example configuration on Layer-3 access-switch that advertises
networks enabled on SVI interfaces; however, keeps them in passive mode and
explicitly allows EIGRP function on uplink port-channel to distribution router. Same
configuration principle must be applied on each EIGRP router including distribution
and core routers:
cr24-3560r-DO(config)#router eigrp 100
cr24-3560r-DO(config-router)# network 10.125.0.0 0.0.255.255
cr24-3560r-DO(config-router)# passive-interface default
cr24-3560r-DO(config-router)# no passive-interface Port-channel1
cr24-3560r-DO#show ip eigrp interface
EIGRP-IPv4:(100) interfaces for process 100
Xmit
Pending
Interface
Po1
Peers
1
Queue
Un/Reliable
0/0
SRTT
1
Mean
Un/Reliable
0/1
cr24-3560r-DO#show ip protocols | inc Passive|Vlan
Passive Interface(s):
Vlan1
Vlan11
Vlan12
Vlan13
Vlan14
Pacing Time
Multicast
Flow Timer
50
Routes
0
cr24-4507-DO(config)#interface Port-channel13
cr24-4507-DO(config-if)# description Connected to cr24-3560r-DO
cr24-4507-DO(config-if)# ip authentication mode eigrp 100 md5
cr24-4507-DO(config-if)# ip authentication key-chain eigrp 100 eigrp-key
Access
cr24-3560r-DO(config)#key chain eigrp-key
cr24-3560r-DO(config-keychain)# key 1
cr24-3560r-DO(config-keychain-key)#
key-string <password>
cr24-3560r-DO(config)#interface Port-channel1
cr24-3560r-DO(config-if)# description Connected to cr24-4507-DO
cr24-3560r-DO(config-if)# ip authentication mode eigrp 100 md5
cr24-3560r-DO(config-if)# ip authentication key-chain eigrp 100 eigrp-key
Tuning EIGRP Protocol Timers
EIGRP protocol functions the same in routed-access as it does in the core network. It is
highly recommended to retain default EIGRP hello and hold timers on distribution and
Layer 3 access-switch and rely on EtherChannel and SSO-based recovery mechanisms,
that offers sub-second network convergence, during individual link or supervisor failure
scenarios.
Building a Resilient Network
The Schools Service Ready Architecture is a high performance, resilient and scalable
network design. A network outage may be caused by the system, human error, or natural
disaster. The Schools SRA is designed to minimize the impact of a failure regardless of
the cause. Network outages may be either Planned or Unplanned.
• Planned Outage—Planned network outage occurs when a portion of the network is
taken out of service as part of a scheduled event (e.g., a software upgrade).
• Unplanned Outage—Any unscheduled network outage is considered an unplanned
outage. Such outages may be caused by internal faults in the network, or devices
due to hardware or software malfunctions.
The network is designed to recover from most un planned outages in less than a second
(milliseconds). In many situations, the user will not even notice the outage occurred. If the
outage lasts longer (several seconds), then the user will notice the lack of application
responsiveness. The network is designed to minimize the overall impact of a unplanned
network outage, and gracefully adjust and recover from many outage conditions.
Figure 19 shows an example of a real-time VoIP application and user impact depending
on duration of outage event.
Schools Design Principles and Foundational Technologies
SBA
50
The high availability framework is based upon the three resiliency categories described
in the previous section. Figure 21 shows which technologies are implemented to achieve
each category of resiliency.
45
Figure 21
Figure 19
VoIP User Impact for minor and major network outage
High-Availability Categories and Technologies
40
Resilient
Goal
35
30
Network Service Availability
25
20
Data Lose (Seconds)
15
Resilient
Strategies
Network
Resiliency
Device
Resiliency
Operational
Resiliency
10
5
0
User Hangs Up
Phone Reset*
EtherChannel
Resilient
Technologies
NSF/SSO
UDLD
ISSU
Stack Wise
IP Event Dampening
Several techniques are used to make the network design more resilient. Deploying
redundant devices and redundant connections between devices, enables the network to
recover from fault conditions. Identifying critical versus non-critical applications, and
network resources optimizes cost performance, by focusing on the most important
elements of the network design. The resiliency of a system design (see Figure 20) is often
catagorized as follows:
Redundant Hardware Components
• Network Resiliency—Provides redundancy during physical link outages (e.g., fiber
cut, bad transceivers, incorrect cabling, etc).
Redundant hardware implementations vary between fixed configuration and modular
Cisco Catalyst switches. Selective deployment of redundant hardware is an important
element of the Schools SRA design which delivers device resiliency.
• Device Resiliency—Protects network during device outage triggered by hardware or
software (e.g. software crash, non-responsive supervisor, etc).
Redundant Power System
• Operational Resiliency—Capabilities which provide network availability even during
planned network outage conditions (e.g., ISSU features which enable software
upgrades while device is operating).
Figure 20
Resiliency Deployment Strategy
Network Resiliency
Device Resiliency
Distribution/Core
Data
Center
Network Resiliency
Device Resiliency
Operational Resiliency
227571
Minimal Impact
to Voice
227569
No Impact
Redundant power supplies protect the device from power outage or power supply failure.
Protecting the power is not only important for the network device, but also the endpoints
that rely on power delivery over the Ethernet network. Redundant power supplies are
deployed differently depending on the switch type:
• Modular Switch—Dual power supplies can be deployed in the modular switching
platforms like the Cisco Catalyst 4500-E. By default, the Cisco Catalyst 4500 power
supply operates in 1+1 redundant mode (both power supplies are active).
• Fixed configuration switch—Fixed configuration switches are deployed with internal
power supplies and they may also use Cisco RPS 2300 external power supply. A
single Cisco RPS 2300 power supply has modular power supplies and fans to deliver
power to multiple switches. Deploying internal and external power-supplies provides
a redundant power solution for fixed configuration switches.
Redundant Network Connectivity
Network Resiliency
Device Resiliency
Network Resiliency
227570
Access
Redundant network connections protect the system from failure due to cable or
transceiver faults. Redundant network connections attached to a single fixed
configuration switch or network module in the Cisco Catalyst 4500 switch do not protect
against internal device hardware or software fault.
Schools Design Principles and Foundational Technologies
SBA
Best practice design is to deploy redundant network modules within the Catalyst 4500
switch and the Cisco 3750-E StackWise Plus solution in the small school site collapsed
core network. Deploying the 3750-E StackWise Plus in critical access-layer switches in
the data center network and in the district office is also best practice. Connecting
redundant paths to different hardware elements provides both network and device
resiliency. See Figure 22.
Cisco Stack Wise Switching Architecture
Member
Switch – 1
Master
Switch – 2
Redundant Network Connectivity
Stack Ring
Redundant StackWise Plus Switch
Single Logical Switch
Stack Ring
Distribution/Core
Distribution/Core
Redundant
Line Cards
Diversed
Fiber Paths
Since Cisco StackWise enables up to 9 switches to appear as one logical switch, it has
centralized management and control functions. Most layer 2 and layer 3 functions are
centrally performed, however layer 2 topology development is distributed, ie each switch
performs the function independently. Table 2 lists network protocol functions and
identifies which are centralized and which are distributed.
Diversed
Fiber Paths
Redundant
Switch
227572
Access
Access
Redundant
Switch
Member
Switch – 3
227573
Figure 22
Figure 23
Table 2
Cisco StackWise Centralized and Distributed Control-Plane
Redundant Control-Plane
The processing software operation is different in standalone or StackWise fixed
configuration switches, and on a supervisor module of a modular switch. Network
communication and forwarding operations can be disrupted when the processing unit
fails, causing a network outage. Network recovery techniques vary based on the different
platforms.
The standalone and non-stackable fixed configuration switches like the Cisco Catalyst
2960 or 3560-E feature power redundancy and network resiliency support; however they
do not protect against a processing unit failure. During a processing unit failure event, all
endpoints attached to the switch are impacted and network recovery time is
undeterministic.
Device resiliency in Cisco StackWise and modular switching platforms provides 1+1
redundancy with enterprise-class high availability and deterministic network recovery
time.
Cisco StackWise
Cisco Catalyst 2975 and Catalyst 3750-E switches can be deployed in StackWise mode
using a special stack cable. Up to nine switches can be integrated into a single stack that
delivers distributed forwarding architecture and unified single control and management
plane. Device level redundancy in StackWise mode is achieved via stacking multiple
switches using the Cisco StackWise technology. One switch from the stack is selected
automatically to serve as the master, which manages the centralized control-plane
process. Cisco StackWise solution provides 1:N redundancy. In the event of a active
master-switch outage, a new master is selected automatically. See Figure 23.
Protocols
Layer 2 Protocols
Layer 3 Protocols
Function
MAC Table
Distributed
Spanning-Tree Protocol
Distributed
CDP
Centralized
VLAN Database
Centralized
EtherChannel - LACP
Centralized
Layer 3 Management
Centralized
Layer 3 Routing
Centralized
Cisco StackWise solution offers network and device resiliency with distributed
forwarding. In the event of a master switch outage, Non Stop Forwarding (NSF) enables
packet forwarding to continue based on current state information, while a new master
switch is selected. New master switch selection is accomplished in the range of 700 to
1000 milliseconds; the amount of time to reestablish the control-plane and develop
distributed forwarding will vary depending on the size and complexity of the network.
Following is a best practice to reduce Layer-3 disruption in the event of a master switch
outage: Determine the master switch with the higher switch priority, and isolate the uplink
Layer-3 EtherChannel bundle path by using physical ports from member switches (i.e.
don't use the master switches ports for Etherchannel uplinks). With NSF capabilities
enabled, this design decreases network downtime during a master-switch outage.
Schools Design Principles and Foundational Technologies
SBA
An understanding of SSO and StackWise components and failover events associated
with NSF provides significant insight in designing a network that enables supervisor
redundancy. The following subsection uses the above concepts and principles to identify
the design parameters, and applies them to develop a best-practice hierarchical network
with the highest availability.
Deploying Resiliency in the Schools Network
Cisco Modular Switch
Network Resiliency
The Cisco Catalyst 4500 modular switch supports redundant supervisors, and Stateful
Switch Over (SSO). When deployed along with NSF, the 4500 provides a enterprise-class
highly available system with network and device resiliency.
SSO is a Cisco IOS service used to synchronize critical forwarding and protocol state
information between redundant supervisors configured in a single chassis. With SSO
enabled, one supervisor in the system assumes the role of active and the other supervisor
becomes the hot-standby. Each is ready to backup the other, thus providing 1:1 hot
redundancy to protect from a control-plane outage. Since both supervisors are active, the
system benefits by using the physical ports from both supervisors during normal
operation.. SSO synchronizes system services such as DHCP snooping, Switched Port
Analyzer (SPAN), security access control lists (ACLs), and QoS policies so ensure the
switch provides the same level of protection and service after a supervisor failover event.
NSF enables packets to continue to be forwarded using existing routing table information,
during switchover. NSF also provides graceful restart to the routing protocol such that
during the failover, the routing protocol remains aware of the change and does not react
by resetting its adjacency. If the routing protocol were to react to the failure event, and
alter routing path information, the effectiveness of stateful switch over would be
diminished.
Many of the design features of the Schools Service Ready Architecture which were
described in 'Deploying School Foundation Services' section earlier, contribute to the
network high availability capabilities. This section focuses on how to implement
additional features which complete the Schools SRA high availablity design.
Etherchannel and UDLD are two design features which are included in the network
foundation services, which contribute to network resiliency.
Implementing IP Event Dampening
Poor signaling or a loose connection may cause continuous port-flap (port alternates
between active state and inactive state).. A single interface flapping can impact the
stability and availability of the network. Route summarization is one technique which
mitigates the impact of a flapping port. Summarization isolates the fault domain with a new
metric announcement by the aggregator and thereby hides the local networks fault within
the domain.
A best practice to mitigate local network domain instability due to port-flap, is
implementing IP Event Dampening on all layer 3 interfaces. Each time the Layer-3
interface flaps the IP dampening tracks and records the flap event. Upon multiple flaps, a
logical penalty is assigned to the port and suppresses link status notification to IP routing
until the port becomes stable. IP event dampening is a local function and does not have
a signaling mechanism to communicate with a remote system. It can be implemented on
each individual physical or logical Layer-3 interface: physical ports, SVI or port-channels.
Following is a example configuration to implement IP Event Damenping
Operational Resiliency Strategy
Designing the network to recover from unplanned outages is important. It is also
important to consider how to minimize the disruption caused by planned outages. These
planned outages can be due to standard operational processes, configuration changes,
software and hardware upgrades, etc.
The same redundant components which mitigate the impact of unplanned outages can
also be used to minimize the disruption caused by planned outages.. The ability to
upgrade individual devices without taking them out of service is enabled by having
internal component redundancy (such as with power supplies, and supervisors)
complemented with the system software capabilities. Two primary mechanisms exist to
upgrade software in a live network:
• Full-image In-Service Software Upgrade (ISSU) on the Cisco Catalyst 4500
leverages dual supervisors to allow for a full, in-place Cisco IOS upgrade. This
leverages the NSF/SSO capabilities of the switch and provides for less than 200
msec of traffic loss during a full Cisco IOS upgrade.
• Network and device level redundancy, along with the necessary software control
mechanisms, guarantee controlled and fast recovery of all data flows following a fault
condition, and provide the ability to manage the fault tolerant infrastructure during
planned outage events. .
Distribution/Core
cr24-4507-DO(config)#int range Port1 , Gig5/6 , Gig6/6 , Vlan 101 - 110
cr24-4507-DO(config-if-range)#dampening
cr24-4507-DO#show interface dampening | be Port
Port-channel1 Connected to cr24-3750ME-DO
Flaps Penalty
Supp ReuseTm
HalfL ReuseV
SuppV
0
0
FALSE
0
5
1000
16000
0
MaxSTm
2000
MaxP Restart
20
The following output illustrates how the IP event dampening keeps track of port flaps and
makes a decision to notify IP routing process based on interface suppression status:
cr24-4507-DO#debug dampening interface
cr24-4507-DO#show logging | inc EvD|IF-EvD
12:32:03.274: EvD(GigabitEthernet5/6): charge penalty 1000, new accum. penalty
1000, flap count 2
12:32:03.274: EvD(GigabitEthernet5/6): accum. penalty 1000, not suppressed
12:32:03.274: IF-EvD(GigabitEthernet5/6): update IP Routing state to DOWN,
interface is not suppressed
cr24-4507-DO#show interface dampening | be 5/6
Flaps Penalty
Supp ReuseTm
HalfL ReuseV
SuppV
MaxSTm
MaxP Restart
Schools Design Principles and Foundational Technologies
2
16000
0
FALSE
0
0
5
1000
SBA
2000
Catalyst 4500-Redundant Internal Power Supply
20
In a multilayer access-distribution design, the Layer-2 and Layer-3 demarcation is at the
collapsed core-distribution device. IP event dampening is enabled on per-logical VLAN
(SVI) interface basis on the collapsed core device. IP event dampening becomes more
effective when each access-layer switch is deployed with a unique set of Layer-2 VLANs.
Assigning unique VLANs on each access-layer switch also helps IP event dampening to
isolate the problem and prevent network faults triggered in a multilayer network. The
following output illustrates how IP event dampening keeps track of individual logical VLAN
networks associated to same Layer-2 physical trunk ports. When a Layer-2 trunk port
flaps, the state of SVI also flaps, and forces dampening to track and penalize unstable
interfaces:
The Cisco Catalyst 4500 provides power to internal hardware components and external
devices like IP phones. All the power is provided by the internal power supply.
Dual-power supplies in the Catalyst 4500 can operate in one of two different modes:
• Redundant Mode—By default, Catalyst 4500 power supply operates in redundant
mode offering 1+1 redundant option. The system determines power capacity and
number of power supplies required based on the power required for all internal and
external power components. Both power supplies must have sufficient power to
support all the installed modules and operate in 1+1 redundant mode.
cr24-4507-DO(config)#power redundancy-mode redundant
cr24-4507-DO#show power supplies
Power supplies needed by system
12:58:41.332: EvD(Vlan101): charge penalty 1000, new accum. penalty 2627, flap
count 3
12:58:41.332: EvD(Vlan101): accum. penalty 2627, now suppressed with a reuse
intervals of 7
12:58:41.332: IF-EvD(Vlan101): update IP Routing state to DOWN, interface is
suppressed
cr24-4507-DO#show interface dampening
Vlan101 Connected to cr24_2960_Dept_1_VLAN
Flaps Penalty
Supp ReuseTm
HalfL ReuseV
SuppV
3
71
FALSE
0
5
1000
16000
0
MaxSTm
2000
:1
Power supplies currently available :2
MaxP Restart
20
• Combined Mode—If the system power requirement exceeds the capacity of a single
power supply, then both power supplies can be combined to increase the capacity.
In this mode, the power system does not provide 1+1 power redundancy. The
following global configuration will enable power supplies to operate in combined
mode:
cr24-4507-DO(config)#power redundancy-mode combined
cr24-4507-DO#show power supplies
Device Resiliency
Power supplies needed by system:2
As described earlier, redundant hardware is an important technique for achieveing device
resiliency. The Schools SRA network design applies hardware redundancy considering
the cost / performance tradeoffs.
Power supplies currently available:2
Implementing Redundant Power Supply
Redundant power supplies can prevent a system outage due to power outage, power
supply or fan hardware failure. All Cisco Catalyst switching platforms supports robust 1+1
redundant power capabilities that can be deployed with internal or external power source
management. See Figure 24.
Figure 24
Redundant Dual
Power Supply
cr36-3750s-ss100#show env rps
Cisco 2300 RPS
Redundant
External
Power Supply
Member
Master
Catalyst 3750-E
Member
227579
RPS Cable
Catalyst 4500
Cisco Redundant Power Supply (RPS) 2300 provides up to 6 RPS ports to provide backup
power to critical access-layer switches in the school network. Additional power resiliency
can be added by deploying dual-power supply to backup to two devices simultaneously.
The Cisco RPS 2300 can be provisioned through the Cisco 3750-E or 3560-E Series
switches using the enable mode CLI:
cr36-3750s-ss100#power rps <switch id> name CiscoRPS
cr36-3750s-ss100#power rps <switch id> port <rps port id> active
Cisco Catalyst Internal and External Power Redundancy Option
Redundant
Internal
Power Supply
Catalyst 29xx and 3xxx - Redundant External Power Supply with RPS
SW StatusRPS NameRPS Serial# RPS Port#HN'
---- -------- ------------ --------------------‡ ?
1
ActiveCiscoRPSFDO1246SG3L1`
2
ActiveCiscoRPSFDO1246SG3L3
3
ActiveCiscoRPSFDO1246SG3L5
RPS Name: CiscoRPS
State: Activexs
PID: PWR-RPS2300
Serial#: FDO1246SG3L
Fan: Good
Schools Design Principles and Foundational Technologies
Temperature: Green
RPS Power Supply A: Present
PID
: C3K-PWR-1150WAC
Serial#
: DTM124000XX
System Power : Good
PoE Power: Good
Watts
: 300/800 (System/PoE)
Redundant RPS
RPS Power Supply B: PresentPower Supply
PID
: C3K-PWR-1150WAC
Serial#
: DTM124000WW
System Power: Good
PoE Power
: Good
Watts
: 300/800 (System/PoE)
DCOut State
Connected Priority BackingUp WillBackup Portname
SW#
-------- -------------------- --------- -------------- ------------------------------1 Active Yes
6
NoYes
cr36-3750s-SS100
1
2 Active Yes
6
NoYes
<>
<>
3 Active Yes
6
NoYes
cr36-3750s_SS100
2
4 Active Yes
6
NoYes
<>
<>
5 Active Yes
6
NoYes
cr36-3750s_SS100
3
6 Active Yes
6
NoYes
<>
<>
Implementing Redundant Control Plane System
The collapsed core device in the district office and school sites (Catalyst 4500 or 3750-E
StackWise) is deployed with redundant supervisor, or StackWise Plus to enable graceful
recovery from switch hardware outage. Any access-switch which is deemed critical may
be deployed as StackWise Plus to improve device resiliency. The implementation for
each switch is different, and is discussed separately in the sections which follows
SBA
Master Switch Election
The centralized control-plane and management plane is managed by the master switch in
the stack. By default, the master switch selection within the ring is performed dynamically
by negotiating several parameters and capabilities between each switch within the stack.
Each StackWise-capable switch is by default configured with priority 1.
cr26-3750r-DO#show switch
Switch/Stack Mac Address : 0023.eb7b.e580
H/W
Switch# Role
Mac AddressPriority
Current
Version
State
---------------------------------------------------------------------------------------* 1 Member0023.eb7b.e580
1
0
2Master 0026.5284.ec80
3Member0025.eb7b.e680
Ready
1
0
1
Ready
0
Ready
As described in previous section, the Cisco StackWise architecture is not SSO-capable.
This means all the centralized Layer-3 functions must be reestablished with the neighbor
switch during a master-switch outage. To minimize the control-plane impact and improve
network convergence the Layer 3 up links should be diverse, originating from member
switches, instead of the master switch. The default switch priority must be increased
manually after identifying the master switch and switch number. The new switch priority
becomes effective after switch reset.
cr26-3750r-DO(config)#switch 2 priority 15
Changing the Switch Priority of Switch Number 2 to 15
cr26-3750r-DO#show switch
Switch/Stack Mac Address : 0026.5284.ec80
H/W
Current
Resilient Cisco StackWise
Switch# Role
Cisco Catalyst 2975 supports StackWise, and is used when a resilient layer-2 access
switch is required. Cisco Catalyst 3750-E supports StackWise, and is used when a
resilient layer 2 or layer 3 access switch is required. Cisco 3750-E StackWise Plus is
deployed for the collapsed core in the small school site network.
StackWise switch provisioning is done dynamically by the StackWise protocol. Cisco IOS
automatically adjusts the interface addressing and its associated configuration based on
the number of provisioned switches in the stack.
----------------------------------------------------------------------------------------
cr26-2975-DO#show run | inc provision
switch 1 provision ws-c2975gs-48ps-l
switch 2 provision ws-c2975gs-48ps-l
switch 3 provision ws-c2975gs-48ps-l
Mac AddressPriority
1Member0023.eb7b.e580
1
* 2 Master 0026.5284.ec80
3Member0025.eb7b.e680
Version
State
0
15
Ready
0
1
0
Ready
Ready
StackWise Layer-3 MAC Management
To provide a single unified logical network view in the network, the MAC addresses of
Layer-3 interfaces on the StackWise (physical, logicl, SVI's, port channel) are derived from
the Ethernet MAC address pool of the master switch in the stack. All the Layer-3
communication from the StackWise switch to the endpoints (like IP phone, PC, servers
and core network system) is based on the MAC address pool of the master switch.
cr26-3750r-DO#show switch
Switch/Stack Mac Address : 0026.5284.ec80
H/W
Switch# Role
Mac AddressPriority
Version
Current
State
Schools Design Principles and Foundational Technologies
SBA
---------------------------------------------------------------------------------------1Member0023.eb7b.e580
1
* 2 Master 0026.5284.ec80
0
15
3Member0025.eb7b.e680
Ready
0
1
Ready
0
.
.
1
3Member0025.eb7b.e680
0
15
1
Ready
0
0
Ready
Ready
Non-Stop Forwarding (NSF)
.
Base ethernet MAC Address
.
1Member0023.eb7b.e580
* 2 Master 0026.5284.ec80
Ready
cr26-3750r-DO#show version
.
-----------------------------------------------------------------------------------------
: 00:26:52:84:EC:80
.
After a master-switch outage, the new master switch in the stack assigns new MAC
addresses to all Layer-3 interfaces, from the local MAC address pool. Once the new MAC
address is assigned, it will force the switch to generate a gratuitous ARP in the network to
make sure no other system is using the same MAC address. The default timer to retain the
MAC address from the failed master switch is four minutes. While the new MAC address
is not assigned on Layer-3 interface and not being propagated and updated in the
network, the traffic will blackhole in the network.
The Cisco Catalyst 3750-E switch in StackWise mode is not SSO-capable. When the
master switch fails, the new master switch is required to reform the Layer-3 adjacencies
with the neighbors in the network. The forwarding architecture in StackWise switch is
designed to provide non-stop forwarding during the master switch outage using NSF
technology. Each 3750-E switch in the stack maintains distributed Layer-3 FIB from the old
master switch and continues to forward upstream traffic, until they are updated by the new
master in the stack ring
To enable NSF capability, explicit configuration must be enabled under the routing
process. NSF-aware feature is enabled by default on all Layer-3 Ethernet switches to
function in helper mode to perform graceful recovery during NSF-capable Cisco 3750-E
master switch outage. NSF-capable system can also operate in NSF aware role:
cr26-3750r-DO#reload slot 2
NSF Capable Layer-3 Switch
Proceed with reload? [confirm]
Switch 2 reloading...
cr36-3750s-SS100(config)#router eigrp 100
cr26-3750r-DO#show switch
cr36-3750s-SS100(config-router)#nsf
Switch/Stack Mac Address : 0023.eb7b.e580
H/W
Switch# Role
Mac AddressPriority
Current
Version
State
---------------------------------------------------------------------------------------* 1 Master 0023.eb7b.e580
2Member000.0000.0000
3Member0025.eb7b.e680
1
1
0
Ready
1
1
Removed
1
Ready
To prevent this network instability, the old MAC address assignments on Layer-3
interfaces can be retained even after the master switch fails. The new active master switch
can continue to use the MAC addresses assigned by the old master switch, which
prevents ARP and routing outages in the network. The default stack-mac timer settings
must be changed in Cisco Catalyst 2975 and 3750-E StackWise switch mode using the
global configuration CLI mode as shown below:
cr26-3750r-DO#show switch
Switch/Stack Mac Address : 0026.5284.ec80
Mac persistency wait time: Indefinite
H/W
Mac AddressPriority
Version
*** IP Routing is NSF aware ***
EIGRP NSF-aware route hold timer is 240
EIGRP NSF enabled
NSF signal timer is 20s
NSF converge timer is 120s
NSF-Aware Layer-3 Switch
cr24-3560r-DO#show ip protocols | inc NSF
*** IP Routing is NSF aware ***
EIGRP NSF-aware route hold timer is 240
NSF Timers
cr26-3750r-DO(config)#stack-mac persistent timer 0
Switch# Role
cr36-3750s-SS100#show ip protocols | inc NSF
Current
State
As depicted in the above show commands, the default NSF-aware system hold timer is
240 seconds. Lowering the timer value may abruptly terminate graceful recovery, causing
network instability.. Best practice is to use the default NSF hold timer, unless it is observed
that NSF recovery takes longer than 240 seconds.
600 seconds after a graceful-recovery starts on a NSF-aware system , NSF clears the
route stale marking and resumes using the synchronized routing database.
! NSF Aware received graceful-restart message from new master switch
Schools Design Principles and Foundational Technologies
11:56:15.365: %DUAL-5-NBRCHANGE: EIGRP-IPv4:(100) 100: Neighbor 10.125.32.3
(Port-channel15) is resync: peer graceful-restart
11:56:15.365: EIGRP: NSF: AS100, NSF or GR initiated by 10.125.32.3 at 00:00:00, flags 0x4
! NSF route hold timer expires and searches and removes all stale route entries
received graceful-restart message from new master switch
12:00:15.392: EIGRP: NSF: AS100. route hold timer expiry
12:00:15.392: DUAL: Search for outdated routes from 10.125.32.3
SBA
and BGP routing protocols, while the NSF-capable feature is supported only on
supervisors IV, V, and V-10G. NSF/SSO on Catalyst 4500 requires a minimum boot ROM
version and must be the same on both supervisors.
For additional details on hardware requirements, refer to the Release Notes at the
following URL:
http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/12.2/53SG/configuration/
NSFwSSO.html#wp1135767
cr24-4507-DO(config)#redundancy
cr24-4507-DO(config-red)# mode sso
cr24-4507-DO(config-red)# main-cpu
Resilient Cisco Catalyst 4500
A modular switching platform like the Cisco Catalyst 4500 is fully NSF/SSO-capable,
providing 1+1 control plane redundancy. In the Catalyst 4500, all the intelligent Layer-2
and Layer-3 functions are performed centrally on the supervisor module. Deploying
redundant supervisor in SSO mode in same system will allow the primary supervisor to
fully synchronize the adjacencies, forwarding, configuration, counters, and more
information on redundant hot-standby supervisor.
The Cisco Catalyst 4500 ports are independent of the supervisor state. Because of this
hardware design, during a supervisor switchover, the ports connected to the failed
supervisor do not go down. Because paths and ports are not down, hardware keeps
forwarding the packet to a valid next-hop while supervisor switchover is occurring.
The configuration and implementation guidelines for implementing NSF/SSO on the
Cisco Catalyst 4500 are the same for district office and school site network designs.
Increasing Supervisor Uplink Port Availability
There are restrictions on which supervisor uplink ports can be actively configured.
Multiple ports can be simultaneously active on the supervisor. However Cisco IOS
Release 12.2(25)SG or later is required for concurrent use of both 10G and 1G. The
Schools SRA uses the 1G interface to connect to the Cisco 3750-MetroE WAN
aggregation switch. To use 10G port in 1G mode with redundancy, the following
configuration must be applied on collapsed core Catalyst 4500 switch:
cr24-4507-DO(config-r-mc)# auto-sync standard
cr24-4507-DO#show module | inc Chassis | 6-E | SSO
Chassis Type : WS-C4507R-E
3
6 Sup 6-E 10GE (X2), 1000BaseX (SFP)
JAE1132SXQ3
WS-X45-SUP6-E
4
6 Sup 6-E 10GE (X2), 1000BaseX (SFP)
JAE1132SXRQ
WS-X45-SUP6-E
3
Active Supervisor
SSOActive
4
Standby Supervisor
SSOStandby hot
The active supervisor dynamically detects the secondary supervisor installed in the
same chassis and initiates several SSO dependency configuration checks. If the SSO
dependency check fails, then the standby supervisor falls back into RPR mode. For
example, IOS release mismatch between two supervisors may not allow SSO to
synchronize.
If the SSO dependency configuration checks successfully pass, then SSO
communication between both supervisors goes through several synchronization states
before it transitions to hot-standby state as illustrated in the following output:
cr24-4507-DO(config)#hw-module uplink mode shared-backplane
cr24-4507-DO(config)#hw-module module 3 port-group 1 select gigabitethernet
cr24-4507-DO#show redundancy states
cr24-4507-DO(config)#hw-module module 4 port-group 1 select gigabitethernet
peer state = 8
my state = 13 -ACTIVE
-STANDBY HOT
. . .
cr24-4507-DO#show hw-module uplink
Active uplink mode configuration is Shared-backplane
Redundancy Mode (Operational) = Stateful Switchover
Redundancy Mode (Configured)
= Stateful Switchover
Redundancy State
= Stateful Switchover
Stateful Switchover (SSO)
Maintenance Mode = Disabled
SSO redundancy mode in the Cisco Catalyst 4500 supervisor is turned on by default
starting with Cisco IOS Release 12.2(20)EWA. To provide 1+1 redundancy, all the technical
specifications between active and standby supervisor must be identical. Also note that
the Cisco Catalyst 4507R and 4510R are the only models that support supervisor
redundancy. SSO is supported on all supervisors running IOS except Sup II-Plus-TS. The
NSF-awareness feature is supported by all the supervisors supporting EIGRP, OSPF, IS-IS,
Manual Swact = enabled
Communications = Up
. . .
Schools Design Principles and Foundational Technologies
All the state-machines and dynamic information of SSO-capable protocols are
automatically synchronized to the standby supervisor module. The hot-standby
supervisor takes over the ownership of control-plane process if the active supervisor
suffers an outage or is removed from the chassis.
Non-Stop Forwarding (NSF)
The IOS based NSF implementation in Cisco Catalyst 4500 is identical to Cisco 3750-E
StackWise-based architecture. If the active supervisor fails or is removed, the standby
supervisor detects the outage and transitions into the active supervisor role to take over
control-plane ownership, within milliseconds. The new supervisor immediately initializes
graceful routing recovery with NSF-aware Layer-3 routers, while it continues to forward
traffic based on pre-switchover hardware FIB information.
SBA
Service Deployed in the Design
Schools SRA design uses an E-line Metro Ethernet with point-to-point service to connect
school sites to the district office. Each school site has a 100 Mbps Metro point-to-point
connection to the service provider Network. As mentioned in the previous section, each
circuit is represented by a VLAN using dot1q trunk. Figure 25 illustrates how this is
implemented.
Figure 25
EVPN Service Used in School WAN Architecture
Virtual Circuit
Point-To-Point
NSF-Capable Layer 3 Switch
School Site 1
cr24-4507-DO(config)#router eigrp 100
cr24-4507-DO (config-router)#nsf
cr24-4507-DO#show ip protocols | inc NSF
*** IP Routing is NSF aware ***
Main School District
Service
Provider
School Site 2
EIGRP NSF-aware route hold timer is 240
EIGRP NSF enabled
NSF converge timer is 120s
School Site 3
NSF Aware Layer 3 Switch
227582
NSF signal timer is 20s
Following is a sample configuration of the WAN interface at the district office:
interface GigabitEthernet1/1/1
cr24-3560r-DO#show ip protocols | inc NSF
*** IP Routing is NSF aware ***
EIGRP NSF-aware route hold timer is 240
description Connected to SP-MPLS-Core-cr24-6500-1
switchport trunk native vlan 801
switchport trunk allowed vlan 501-550
switchport mode trunk
logging event trunk-status
WAN Design
load-interval 30
In the Schools Service Ready Architecture, the school sites are connected to the district
office over Wide Area Network (WAN) links. This section discusses how to design and
deploy the WAN for Schools SRA. The primary components of WAN architecture are as
follows:
carrier-delay msec 0
priority-queue out
mls qos trust dscp
spanning-tree portfast trunk
• WAN technology
• Bandwidth capacity planning
spanning-tree bpdufilter enable
• WAN IP addressing structure
• Routing
service-policy output School-1to50-Parent-Policy-Map
• QoS
The Schools SRA design uses Metro Ethernet service as the WAN transport between
school sites, and the district office.
spanning-tree guard root
hold-queue 2000 in
hold-queue 2000 out
In the above configuration, the link is carrying 50 VLANs, which are connected to 50
school sites.
Schools Design Principles and Foundational Technologies
Planning sufficient bandwidth capacity is a critical component of the overall WAN design.
Application performance depends largely on guaranteed level of bandwidth at school
sites and the district office. This section discusses the general WAN bandwidth capacity
planning steps, and how this has been implemented in the School SRA.
The School district muct purchase the MetroE service from the local Service Provider.
The amount of bandwidth capacity at each school, and at the district office must be
sufficient to meet the anticipated network load, and some margin for peak usage, and to
allow future growth. The bandwidth is shared based on the four-class QoS model, for
optimal service delivery. Logical bandwidth assignment to each circuit must be
symmetric at the school and at the district office. A mismatch in bandwidth capacity will
force traffic drop in the SP core due to in-consistent bandwidth SLAs.
The WAN bandwidth capacity may vary between school sites, but the design principles
and implementation (bandwidth sharing, routing, QoS, multicast ) are the same.
Note The district office WAN router is an aggregator that logically connects to multiple
schools over a single media. The School SRA district office WAN device is the
Cisco 3750ME. The media type connecting to the Metro WAN MUST be GigE,
since the 3750ME does not negotiate to lower speeds.
Calculating the optimum guaranteed bandwidth required at the district office is done by
considering the following factors:
• Number of school sites.
• Bandwidth required at each location.
• Platform scalability limits, mainly, at district office.
To describe how much bandwidth is required at each school site, we use two terms, CIR,
Interface speed.
• CIR—Committed bandwidth that is guaranteed from the service provider, based on
the logical connection.
• Interface speed—The interface speed is actual Ethernet handoff, which is 1Gbps for
both school sites and district office.
For example, let us consider a scenario where there are three school sites, and one district
office. The CIR required at each school site is 100Mbps, and since there are three school
sites, the district office needs three virtual circuits each having a CIR of 100Mbs, which
also means that the aggregate bandwidth at district office is 300Mbps. Figure 26
illustrates this point.
Figure 26
Bandwidth Capacity Panning for Three School Sites
Interface Speed: 1000Mbps
CIR Bandwidth: 100Mbps
Interface Speed: 1000Mbps
CIR Bandwidth for each site: 100Mbps
Aggregate Bandwidth Capacity: 300Mbps
School Site 1
Service
Provider
Main School District
School Site 2
School Site 3
227584
Bandwidth Capacity Planning
SBA
Similarly, if the CIR required at each school site is 100Mbps, and if there are 100 school
sites, then the bandwidth required at district office is 10Gbps. To support an aggregate
CIR bandwidth of 10Gbps at the district office, we need to think about scalability limits on
the WAN aggregation box.
If the aggregated logical connection speed to the schools exceed the media capacity on
3750-ME, which is the WAN aggregator for our design, then there are two design options:
1. .Migrate to Modular a switching platform (such as Catalyst 6500) - Migrating to a
modular switching platform in the WAN aggregation tier enables higher bandwidth
capacityy,and may reduce operational and management complexities.
2. Deploy another 3750-ME -Deploying another 3750-ME is the simplest way to scale
the WAN capacity. Deploying another set of 3750-ME does not change any WAN
design principles, and except for VLAN and IP address, all the configurations can be
replicated to the secondary system.
Implementation
This section describes how the WAN is implemented in the Schools SRA reference
design, which was validated in the lab..
• The district office has dual WAN connections, and each connection is 1Gbps.
• On each WAN connection there are 50 Virtual circuits, each with CIR of 20Mbps.
• The school sites have 1Gbps connection, and CIR value of 20Mbs on each circuit.
Figure 27 shows how this design is validated with 100 school sites.
Schools Design Principles and Foundational Technologies
Figure 27
SBA
Bandwidth Capacity Planning for 100 School Sites
load-interval 30
hold-queue 2000 in
hold-queue 2000 out
Routing for WAN Connections
School Site 1
This section discusses how to implement routing on the WAN interfaces. The key
consideration when designing the routing protocol is summariztion.
Summarization on network boundaries is very important to design as it prevents
unnecessary routing updates to flow across the WAN interface, when there is a link-state
change in the network. For example, let us consider a school district where there are
subnets in the following range:
Interface Speed: 1000Mbps
CIR Bandwidth: 20Mbps
Interface Speed: 1000Mbps
CIR Bandwidth for each site: 20Mbps
Aggregate Bandwidth Capacity: 1000Mbps
Main School District
School Site 50
10.127.0.0/26
Service
Provider
10.127.0.64/26
10.127.0.128/26
Interface Speed: 1000Mbps
CIR Bandwidth for each site: 20Mbps
Aggregate Bandwidth Capacity: 1000Mbps
School Site 11
.
.
.
10.127.7.64/26
School Site 100
227585
Interface Speed: 1000Mbps
CIR Bandwidth: 20Mbps
IP Address Aggregation
This section describes how to aggregate IP address space at the school sites, and the
district office on the WAN interface.
Since the above subnets belong to a particular school district, they could be summarized
as 10.127.0.0/21. The following configuration shows how to perform summarization on the
WAN interface, which is Vlan501 in this example:
School Site:
interface Vlan501
description Connected to cr24-3750ME-DO
As explained in the previous section, all the school sites are connected to the district
office using point-to-point links, which means that every school site should be on a
different IP subnet. It is common for customers to deploy using /30 subnet for each school
site. This uses up to 4 addresses for each subnet. Best practice recommendation is to use
/31 subnets. This approach only uses two addresses in each link. The following
configurations show how to deploy this at a school site or district office:
dampening
School Site:
ip authentication key-chain eigrp 100 eigrp-key
interface Vlan501
description Connected to cr24-3750ME-DO
dampening
ip address 10.126.0.1 255.255.255.254
no ip redirects
no ip unreachables
ip authentication mode eigrp 100 md5
ip authentication key-chain eigrp 100 eigrp-key
ip pim sparse-mode
ip summary-address eigrp 100 10.127.0.0 255.255.248.0 5
load-interval 30
District Office:
interface Vlan501
description Connected to cr35-4507-SS1
dampening
ip address 10.126.0.0 255.255.255.254
no ip redirects
no ip unreachables
ip authentication mode eigrp 100 md5
ip authentication key-chain eigrp 100 eigrp-key
ip pim sparse-mode
ip summary-address eigrp 100 10.124.0.0 255.252.0.0 5
ip address 10.126.0.1 255.255.255.254
no ip redirects
no ip unreachables
ip authentication mode eigrp 100 md5
ip pim sparse-mode
ip summary-address eigrp 100 10.127.0.0 255.255.248.0 5
load-interval 30
District Site:
interface Vlan501
description Connected to cr35-4507-SS1
dampening
ip address 10.126.0.0 255.255.255.254
no ip redirects
no ip unreachables
ip authentication mode eigrp 100 md5
ip authentication key-chain eigrp 100 eigrp-key
ip pim sparse-mode
ip summary-address eigrp 100 10.124.0.0 255.252.0.0 5
load-interval 30
hold-queue 2000 in
hold-queue 2000 out
Schools Design Principles and Foundational Technologies
SBA
WAN QoS Design
Figure 29
QoS design is particularly important when using Ethernet as the WAN, since the router or
switch on the WAN edge might believe they have complete line rate available to transmit.
If the WAN device transmits at full line rate into the WAN, the Service Provider network will
drop packets exceeding the CIR (ie the committed rate agreed to with Service Provider).
Figure 28 shows what may happen without a proper QoS design.
Policing at Service provider due to lack of proper QoS at district office, and school sites
GE Speed Interface
to SP MetroE
VLAN 502
Remote School Site 1
1
ow
Inbound Policing
fic
Fl
Traffic Flow
Service
Provider
Main School District
fic
Fl
ow
227586
Table 3 shows how these classes are defined.
School Site 3
Proper QoS policies implemented at the district office and school site will prevent packets
from being dropped at service provider network.
WAN QoS Policy at District Office
The district office has several point to point circuits; one connecting to each school site.
The QoS policy at the district office has the following objectives:
• The aggregate traffic going out to the school site does not exceed the school site CIR
(20Mbps for the lab testbed).
• All the traffic going out is put into four classes.
To accomplish the above objectives, Hierarchical Class Based Weighted Fair Queuing
(HCBWFQ) is implemented. To learn more about HCBWFQ, refer to Ethernet Access for
Next Generation Metro and Wide Area Networks Design Guide at the following URL:
http://www.cisco.com/en/US/docs/solutions/Enterprise/WAN_and_MAN/Ethernet_Acc
ess_for_NG_MAN_WAN_V3.1_external.html
Implementing HCWFQ, requires two policies:
• Parent policy that defines the aggregate shape rate
• Child policy that enables queuing within the shaped rate.
Figure 29 shows the representation of hierarchical policy.
1
2
Child Policy: Per-VLAN Queueing
Queue-1 – Real-time Class (PQ) – 30% of Per-VLAN BW
Queue-2 – Gold Class (CBWFQ) – 5% of Per-VLAN BW
Queue-3 – Silver Class (CBWFQ) – 30% of Per-VLAN BW
Queue-4 – Best-Effort (WFQ/WRED) – 35% of Per-VLAN BW
School Site 2
af
Parent Policy:
Per-VLAN Sub-rate
Traffic Shaping to
Remote School Site 2
School Site 1
Traffic Flow
Tr
VLAN 501
Remote School Site 2
Parent Policy:
Per-VLAN Sub-rate
Traffic Shaping to
Remote School Site 1
af
Tr
1
Parent Policy: Per-Port aggregated Traffic Shape
from District School to all remote School Sites
227587
Figure 28
Hierarchical policy implementation at District Ofice
Table 3
Class Definitions
Class
Queuing type
Bandwidth Allocation
REAL_TIME
LLQ
30%
GOLD
CBWFQ
5%
SILVER
CBWFQ
30%
DEFAULT
CBWFQ
35%
Following is the configuration of the QoS policy at the district office. This configuration is
for one VLAN:
class-map match-all School_Site1
school site
description cr2-4507-SS1
match vlan 501
This class map would match the traffic going to a
policy-map School-Child-Policy-Map
This is child policy
class REAL_TIME
priority
police cir percent 30 conform-action set-cos-transmit 5 exceed-action drop
violate-action drop
class GOLD
bandwidth percent 5
set cos 3
class SILVER
bandwidth percent 30
set cos 2
class class-default
bandwidth percent 35
set cos 0
!
Following is the configuration of the parent policy;, which shapes to 20Mbps for each
school site in this example:
Policy Map School-1to50-Parent-Policy-Map
This is parent policy map
Schools Design Principles and Foundational Technologies
Class School_Site1
shape average 20000000 (bits/sec)
service-policy School-Child-Policy-Map
SBA
switchport trunk native vlan 801
This is child policy map
switchport trunk allowed vlan 501
switchport mode trunk
logging event link-status
After defining the policies, they are applied to WAN interfaces. The following example
shows the configuration of Metro switch on its WAN interface:
interface GigabitEthernet1/1/1
description Connected to SP-MPLS-Core-cr24-6500-1
switchport trunk native vlan 801
switchport trunk allowed vlan 501-550
switchport mode trunk
logging event trunk-status
load-interval 30
carrier-delay msec 0
priority-queue out
mls qos trust dscp
spanning-tree portfast trunk
spanning-tree bpdufilter enable
spanning-tree guard root
max-reserved-bandwidth 100
service-policy output School-1to50-Parent-Policy-Map
hold-queue 2000 in
hold-queue 2000 out
load-interval 30
carrier-delay msec 0
qos trust dscp
udld port disable
tx-queue 1
bandwidth 1 mbps
tx-queue 2
bandwidth 7 mbps
tx-queue 3
bandwidth 6 mbps
priority high
tx-queue 4
The policy-map
bandwidth 6 mbps
no cdp enable
spanning-tree portfast trunk
After completing the QoS policy at district office, we need to define the QoS policy at
school sites.
spanning-tree bpdufilter enable
spanning-tree guard root
service-policy output WAN-EGRESS-PARENT
WAN QoS Policy at School Site
The objectives at the school sites are similar to the one at the district office, which is:
• Ensure that 20Mbps is the maximum aggregate traffic leaving the WAN device,
• Ingress traffic is queued in four classes.
The school site implementation is different from the district office (due to lack of HCBWFQ
support). The following configuration shows how to implement the Qos policy without
HCBWFQ.
The first step is to queue the ingress traffic in the four queues. Table 4 shows the queues,
and the bandwidth allocated for each.
The above configuration ensures that each class of traffic is queued as per the table
shown above. However, the "bandwidth" would only ensure the minimum amount of
bandwidth available. It does not control the upper threshold, which needs to be 20Mbps
in our example. Therefore, to make sure that the traffic on the egress interface does not
exceed 20Mps, we have a WAN-EGRESS-PARENT policy that polices the traffic to
20Mbps. Following is the configuration of the WAN egress policy:
cr35-4507-SS1#show policy-map WAN-EGRESS-PARENT
Policy Map WAN-EGRESS-PARENT
Class class-default
Table 4
police 20 mbps 1000 byte conform-action transmit exceed-action drop
Queuing Ingress Traffic
service-policy WAN-EGRESS-CHILD
Class
Queuing Type
Bandwidth Allocation
REAL_TIME
Per-class
6mbps
GOLD
Per-class
1mbps
SILVER
Per-class
7mpbs
DEFAULT
Per-class
6mbps
Following is the configuration of egress interface on the school-site:
interface GigabitEthernet1/1
description Connected to MetroE-Core-cr25-6500-1
switchport trunk encapsulation dot1q
cr35-4507-SS1#
Core Distribution Integration
The core/distribution component of the schools SRA is a key element in delivering a
resilient network, while providing a network configuration that is easy to manage and to
deploy. This chapter discusses both core/distribution models for the school sites, the
Cisco Catalyst 3750 stack model and the Cisco Catalyst 4500 modular switch model. This
chapter summarizes different connection types to the core/distribution models, and the
key features of those connections.
Schools Design Principles and Foundational Technologies
SBA
Large School Design
no ip redirects
The basic modular switch School topology is shown in Figure 30. This design is based
upon a collapsed core/distribution mode, and a Layer-2 access distribution model. In this
type of design all of the IP subnets are defined on the Catalyst 4500 modular switch, and
access to these subnets is controlled by the VLANs that are trunked to the switches.
no ip unreachables
If desired a Layer-3 access switch model may be implemented, the physical topology
does not change, and centrality of EtherChannel to the design does not change. The
simplicity of the network design not only allows Layer-2 or Layer-3 access layers, it also
allows a hybrid deployment. This allows the majority of clients on the switch use Layer-3
access features, but a group of legacy client are able to continue to use a Layer-2 network.
This can be useful when migrating from clients that do not use IP, or rely heavily upon
locally broadcast information to learn about services or devices on the network.
The Catalyst 4500 modular core provides resilient connections to the access LAN
switches, local server switch, WLC, and SRST Router through EtherChannel. The NAC
CAS appliance does not support EtherChannel, and the two connections are used to
connect to the trusted and untrusted interfaces of the appliance.
The WAN connection to the Catalyst 4500 modular is a single connection
!
Figure 30
The following are examples of the port channel configuration on core/distribution Catalyst
4500 modular switch and an example access switch. A similar configuration would be
applied to each access switch connection with the same or different VLANs as required.
From an IP routing or services level there is no requirement to span the same VLAN to
multiple switches, but if there is a requirement to support legacy protocols such as
AppleTalk at the school these AppleTalk VLANs can be easily spanned to different access
switches as required
Stacked Switch School Schematic
WAN
CAS
load-interval 30
…
interface Vlan110
description Connected to cr35_2960_Dept_10_VLAN
dampening
ip address 10.127.2.65 255.255.255.192
ip helper-address 10.125.31.2
no ip redirects
no ip unreachables
ip pim sparse-mode
load-interval 30
Example Port Channel Configuration
Example Catalyst 4500Modular Switch Port Channel Configuration
SRST
PSTN
ip pim sparse-mode
interface Port-channel11
V
description Connected to cr35-2960-SS1
WLC
switchport
switchport trunk encapsulation dot1q
Access
Switch
Access
Switch
switchport trunk native vlan 802
switchport trunk allowed vlan 101-110
227525
Server
Switch
Core/Distribution Virtual Interfaces
switchport mode trunk
logging event link-status
load-interval 30
carrier-delay msec 0
The following is an example configuration of the switch virtual interfaces (SVIs) configured
on the core/distribution Catalyst 4500modular switch. This SVIs are trunked to the access
switches as required, and access to the VLANs are controlled by the switchport trunk
allowed vlan command applied on the port channels. The same basic configuration is
used for the server switch
qos trust dscp
Example 2960 Port Channel Configuration
interface Port-channel1
.
description Connected to cr35-4507-SS1
interface Vlan101
switchport trunk native vlan 802
description Connected to cr35_2960_Dept_1_VLAN
switchport trunk allowed vlan 101-110,201
dampening
switchport mode trunk
ip address 10.127.0.1 255.255.255.192
ip arp inspection trust
ip helper-address 10.125.31.2
load-interval 30
Schools Design Principles and Foundational Technologies
carrier-delay msec 0
SBA
SRST Connection
hold-queue 2000 in
hold-queue 2000 out
ip dhcp snooping trust
WLC Connection
The WLC Connection to the core/distribution stack is fundamentally the same as an
access switch connection, with different VLANs, and the exception of using a different
QoS trust mode, where the CoS values from the WLC, are trusted. The following is an
example Catalyst 4500modular switch Port Channel configuration:
Interface Port-channel12
description Connected to WLC-SS2
switchport trunk encapsulation dot1q
switchport trunk native vlan 802
switchport trunk allowed vlan 111-120
switchport mode trunk
load-interval 30
carrier-delay msec 0
ip dhcp snooping trust
NAC CAS Connection
The NAC CAS connection to the core/distribution switch. This is not an EtherChannel
connection, but two switch ports are consumed. The two ports consist of a untrusted port
for connecting client VLANs to the CAS prior to them completing the NAC process, and a
trusted port that connects the NAS to the client VLANs used once clients have
successfully completed the NAC process. The two, trusted and untrusted, ports are
required even if OOB NAC is used, as the CAS requires access to the trusted VLANs
during the NAC process. The following is an example of the configuration.
Core/Distribution NAC CAS Configuration
interface GigabitEthernet1/0/4
description NAC Trusted Eth0
switchport trunk encapsulation dot1q
Sample Configuration
The SRST connection to the core/distribution is another EtherChannel connection. The
differences between the SRST connection and the access switch connections are that a
trunk connection is not required, and that the SRST interfaces are router interfaces,
requiring a slightly different connection. The following is an example of the configuration.
interface Port-channel3 
description to isr for simulated PSTN
GW for school2 
switchport access vlan 303 
switchport mode access 
interface GigabitEthernet2/0/20 
switchport access vlan 303 
switchport mode access 
mls qos trust dscp 
channel-group 3 mode on 
end 

interface GigabitEthernet3/0/20 
switchport access vlan 303 
switchport mode access 
mls qos trust dscp 
channel-group 3 mode on 
end 
WAN Connection
The WAN connection is a single port connection from the core/distribution switch, and
therefore there is no EtherChannel. The key component in the WAN connection
configuration is the QoS implementation, that provides traffic shaping and limiting on this
interface to ensure that the voice and video are given appropriate priority, but do not
starve other applications of the throughput. An example of the WAN connection
configuration is shown below.
WAN Port Sample Configuration-Core/Distribution
switchport trunk allowed vlan 48,57,62
switchport mode trunk
spanning-tree portfast trunk
!
…!
interface GigabitEthernet1/0/8
description NAC Untrusted Eth1
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 61,248,257
switchport mode trunk
spanning-tree portfast trunk
interface Port-channel3 
description port-channel to 4500 
…
! 
interface GigabitEthernet0/0 
description
$ETH-LAN$$ETH-SW-LAUNCH$$INTF-INFO-GE 0/0$ 
no ip address 
duplex auto 
speed auto 
media-type rj45 
no keepalive 
channel-group 3 
! 
interface GigabitEthernet0/1 
no ip address 
duplex auto 
speed auto 
media-type rj45 
no keepalive 
channel-group 3 
interface GigabitEthernet3/0/52
description Connected to MetroE-Core
switchport trunk encapsulation dot1q
switchport trunk native vlan 801
switchport trunk allowed vlan 650
switchport mode trunk
load-interval 30
carrier-delay msec 0
srr-queue bandwidth shape 35 15 25 25
srr-queue bandwidth limit 10
priority-queue out
mls qos trust dscp
no cdp enable
spanning-tree portfast trunk
spanning-tree bpdufilter enable
hold-queue 2000 in
hold-queue 2000 out
Schools Design Principles and Foundational Technologies
SBA
Core/Distribution Virtual Interfaces
interface Vlan650
dampening
ip address 10.126.1.99 255.255.255.254
no ip redirects
no ip unreachables
ip pim sparse-mode
ip authentication mode eigrp 100 md5
ip authentication key-chain eigrp 100 eigrp-key
ip summary-address eigrp 100 10.127.112.0 255.255.248.0 5
load-interval 30
hold-queue 2000 in
hold-queue 2000 out
Example Port Channel Configuration
The following example shows an example of the port channel configuration on
core/distribution Catalyst 3750 stack and an example access switch. A similar
configuration would be applied to each access switch connection with the same or
different VLANs as required. From an IP routing or services level there is no requirement
to span the same VLAN to multiple switches, but if there is a requirement to support
legacy protocols such as AppleTalk at the school these AppleTalk VLANs can be easily
spanned to different access switches as required.
Small School Design
The basic stacked switch school topology is shown in Figure 2.This design is based upon
a collapsed core/distribution mode, and a Layer-2 access distribution model. In this type
of design, all of the IP subnets are defined on the Catalyst 3750 stacked switch, and
access to these subnets is controlled by the VLANs that are trunked to the switches.
The Catalyst 3750 stackwise core provides resilient connections to the access LAN
switches, local server switch, WLC, and SRST router through EtherChannel. The NAC
Appliance does not support EtherChannel, and the two connections are used to connect
to the trusted and untrusted interfaces of the CAS.
The WAN connection to the Catalyst 3750 stack is a single Ethernet connection
Figure 31
Stacked Switch School Schematic
WAN
CAS
SRST
V
WLC
Server
Switch
Access
Switch
Access
Switch
227526
PSTN
Below is an example configuration of the SVIs configured on the core/distribution Catalyst
3750 stack. These SVIs are trunked to the access switches as required, and access to the
VLANs are controlled by the switchport trunk allowed vlan command applied on the port
channels. The same basic configuration is used for the server switch.
Example Catalyst 3750 Stack Port Channel
Configuration
Example 2960 Port Channel Configuration
Interface Port-channel11 
description Connected to 2960-SS2 
switchport trunk encapsulation dot1q 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
load-interval 30 
carrier-delay msec 0 
ip dhcp snooping trust
Interface Port-channel1 
description Connected to 3750-Core-SS2 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
ip dhcp snooping trust
interface GigabitEthernet1/0/49 
description Connected to 2960-SS2 
switchport trunk encapsulation dot1q 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
load-interval 30 
carrier-delay msec 0 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
channel-group 11 mode active 
spanning-tree guard root 
ip dhcp snooping trust 
! 
interface GigabitEthernet3/0/49 
description Connected to 2960-SS2 
switchport trunk encapsulation dot1q 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
load-interval 30 
carrier-delay msec 0 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
channel-group 11 mode active 

spanning-tree guard root 
ip dhcp snooping trust
interface GigabitEthernet0/1 
description Connected to 3750-Core-SS2 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol lacp 
channel-group 1 mode active 
ip dhcp snooping trust 
! 
interface GigabitEthernet0/2 
description Connected to 3750-Core-SS2 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol lacp 
channel-group 1 mode active 
ip dhcp snooping trust
WLC Connection
The WLC connection to the core/distribution stack is fundamentally the same as an
access switch connection, with different VLANs, and the exception of using a different
QoS trust mode, where the CoS values from the WLC, are trusted. The following is an
example of the configuration.
Schools Design Principles and Foundational Technologies
Example Catalyst 3750 Stack Port Channel Configuration
Interface Port-channel12
SBA
successfully completed the NAC process. The two, trusted and untrusted, ports are
required even if OOB NAC is used, as the CAS requires access to the trusted VLANs
during the NAC process. The following is an example of the configuration.
description Connected to 2960-SS2
switchport trunk encapsulation dot1q
Core/Distribution NAC CAS Configuration
switchport trunk native vlan 802
switchport trunk allowed vlan 111-120
interface GigabitEthernet1/0/4
description NAC Trusted Eth0
switchport mode trunk
switchport trunk encapsulation dot1q
load-interval 30
switchport trunk allowed vlan 48,57,62
carrier-delay msec 0
switchport mode trunk
ip dhcp snooping trust
spanning-tree portfast trunk
interface GigabitEthernet1/0/48
description Connected to WLC-SS2
switchport trunk encapsulation dot1q
switchport trunk native vlan 802
switchport trunk allowed vlan 110-120
switchport mode trunk
load-interval 30
carrier-delay msec 0
srr-queue bandwidth share 1 30 35 5
!
!
interface GigabitEthernet1/0/8
description NAC Untrusted Eth1
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 61,248,257
switchport mode trunk
spanning-tree portfast trunk
SRST Connection
priority-queue out
udld port
mls qos trust coschannel-group 11 mode active
The SRST connection to the core/distribution is another EtherChannel connection. The
differences between the SRST connection and the access switch connections are that a
trunk connection is not required, and that the SRST interfaces are router interfaces,
requiring a slightly different connection. The following is an example of the configuration.
spanning-tree guard root
!
interface GigabitEthernet3/0/48
description Connected to WLC-SS2
switchport trunk encapsulation dot1q
switchport trunk native vlan 802
switchport trunk allowed vlan 110-110,
switchport mode trunk
load-interval 30
carrier-delay msec 0
srr-queue bandwidth share 1 30 35 5
priority-queue out
udld port
mls qos trust coschannel-group 11 mode active
spanning-tree guard root
NAC CAS Connection
The NAC CAS connection to the core/distribution switch. This is not an EtherChannel
connection, but two switch ports are consumed. The two ports consist of a untrusted port
for connecting client VLANs to the CAS prior to them completing the NAC process, and a
trusted port that connects the NAS to the client VLANs used once clients have
interface Port-channel3 
description to isr for simulated PSTN GW
for school1 
switchport access vlan 303 
switchport mode access 
interface GigabitEthernet2/0/20 
switchport access vlan 303 
switchport mode access 
mls qos trust dscp 
channel-group 3 mode on 
end 

interface GigabitEthernet3/0/20 
switchport access vlan 303 
switchport mode access 
mls qos trust dscp 
channel-group 3 mode on 
end 
interface Port-channel3 
description port-channel to core stack 
ip address 10.40.63.9 255.255.255.252 
hold-queue 150 in 
! 
interface GigabitEthernet0/0 
description
$ETH-LAN$$ETH-SW-LAUNCH$$INTF-INFO-GE 0/0$ 
no ip address 
duplex auto 
speed auto 
media-type rj45 
no keepalive 
channel-group 3 
! 
interface GigabitEthernet0/1 
no ip address 
duplex auto 
speed auto 
media-type rj45 
no keepalive 
channel-group 3 
Schools Design Principles and Foundational Technologies
SBA
WAN Connection
District Office Design
The WAN connection is a single port connection from the core/distribution switch, and
therefore there is no EtherChannel. The key component in the WAN connection
configuration is the QoS implementation, that provides traffic shaping and limiting on this
interface to ensure that the Voice and Video are given appropriate priority, but do not
starve other applications of the throughput. An example of the WAN connection
configuration is shown below.
The school district office network provides the infrastructure that both severs the users
local to the school headquarters and that supports the centralized services used across
all the school sites. This chapter discusses the key aspects of the network design of the
school district office, including core/distribution models, Internet connectivity and
services block.
Compared to the previously discussed school site design, there are four main differences
in the district office design:
• The use of the Supervisor 6—The Supervisor 6 supports hierarchical QoS.
interface GigabitEthernet3/0/52
description Connected to MetroE-Core
switchport trunk encapsulation dot1q
switchport trunk native vlan 801
switchport trunk allowed vlan 650
switchport mode trunk
• The Metro Ethernet Switch Connection—The aggregation and QoS policy
enforcement point for the Metro Ethernet WAN connection to the schools
• The Services Block Switch Connection—The district office "mini-Data Center" for the
management and services servers for the district and the schools
priority-queue out
• The ASA Firewall Connection-The firewall connection to the Internet
District Office Partial Schematic shows a schematic of the district office network. Aside
from providing core/distribution services to the access switches, the Cisco Catalyst 4500
modular switch in the district office connects the school WAN to the district office, the
services such as Internet access and the Services Block of the SRA.
mls qos trust dscp
Figure 32
load-interval 30
carrier-delay msec 0
srr-queue bandwidth shape 35 15 25 25
srr-queue bandwidth limit 10
District Office Partial Schematic
no cdp enable
spanning-tree portfast trunk
spanning-tree bpdufilter enable
WAN
hold-queue 2000 in
hold-queue 2000 out
interface Vlan650
ME
dampening
Metro
Ethernet
Switch
SRST
ip address 10.126.1.99 255.255.255.254
CAS
no ip redirects
SRST
V
no ip unreachables
ip pim sparse-mode
ip authentication mode eigrp 100 md5
Internet
ip authentication key-chain eigrp 100 eigrp-key
ip summary-address eigrp 100 10.127.112.0 255.255.248.0 5
load-interval 30
WLC
ASA
Firewall
hold-queue 2000 out
Access
Switch
Access
Switch
Services Block
Switch
227527
hold-queue 2000 in
Metro Ethernet Connection Configuration
Port-Channel Configuration on the Core/Distribution Catalyst 4500 Modular Switch and
the Catalyst 3750Metro Ethernet Sw shows an example of the port-channel configuration
on the core/distribution Catalyst 4500 modular switch and the Catalyst 3750 Metro
Ethernet switch. This is a Layer-3 connection where both the core/distribution switch and
the Metro Ethernet switch are part of the same EIGRP AS. The most significant difference
Schools Design Principles and Foundational Technologies
in this configuration from the School design using the Catalyst 4500 modular switch is the
QoS configuration on the Catalyst 4500 interface; this is primarily due to the district office
using hierarchical QoS features of a Supervisor 6 module, rather than the Supervisor 5
used in the School SRA.
Table 5
Port-Channel Configuration on the Core/Distribution Catalyst 4500 Modular Switch
and the Catalyst 3750Metro Ethernet Switch
Example Catalyst 4500 Modular Switch
Configuration
Example Catalyst 3750ME Switch
Configuraiton
interface Port-channel1 
description Connected to 3750ME-DO 
dampening 
ip address 10.125.32.4 255.255.255.254 
ip authentication mode eigrp 100 md5 
ip authentication key-chain eigrp 100
eigrp-key 
ip pim dr-priority 100 
ip pim sparse-mode 
ip summary-address eigrp 100 10.125.0.0
255.255.0.0 5 
logging event link-status 
load-interval 30 
carrier-delay msec 0 
service-policy output PQ-POLICER
interface Port-channel1 
description Connected to 4507-DO 
no switchport 
dampening 
ip address 10.125.32.5 255.255.255.254 
ip authentication mode eigrp 100 md5 
ip authentication key-chain eigrp 100
eigrp-key 
ip pim sparse-mode 
ip summary-address eigrp 100 10.127.0.0
255.255.0.0 5 
ip summary-address eigrp 100 10.126.0.0
255.255.0.0 5 
logging event bundle-status 
load-interval 30 
carrier-delay msec 0 
hold-queue 2000 in 
hold-queue 2000 out
SBA
Table 5
Port-Channel Configuration on the Core/Distribution Catalyst 4500 Modular Switch
and the Catalyst 3750Metro Ethernet Switch (continued)
Example Catalyst 4500 Modular Switch
Configuration
Example Catalyst 3750ME Switch
Configuraiton
interface GigabitEthernet3/3 
no switchport 
no ip address 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 1 mode desirable 
service-policy output EGRESS-POLICY 
! 
interface GigabitEthernet4/3 
no switchport 
no ip address 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 1 mode desirable 
service-policy output EGRESS-POLICY
interface GigabitEthernet1/0/1 
description Connected to cr24-4507-DO 
no switchport 
no ip address 
logging event bundle-status 
load-interval 30 
carrier-delay msec 0 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol pagp 
channel-group 1 mode desirable 
! 
interface GigabitEthernet1/0/2 
description Connected to cr24-4507-DO 
no switchport 
no ip address 
logging event bundle-status 
load-interval 30 
carrier-delay msec 0 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol pagp 
channel-group 1 mode desirable
policy-map PQ-POLICER 
class PRIORITY-QUEUE 
police cir 300000000 
conform-action transmit 
exceed-action drop policy-map
EGRESS-POLICY 
class PRIORITY-QUEUE 
priority 
class CONTROL-MGMT-QUEUE 
bandwidth remaining percent 10 
class MULTIMEDIA-CONFERENCING-QUEUE 
bandwidth remaining percent 10 
class MULTIMEDIA-STREAMING-QUEUE 
bandwidth remaining percent 10 
class TRANSACTIONAL-DATA-QUEUE 
bandwidth remaining percent 10 
dbl 
class BULK-DATA-QUEUE 
bandwidth remaining percent 4 
dbl 
class SCAVENGER-QUEUE 
bandwidth remaining percent 1 
class class-default 
bandwidth remaining percent 25 
dbl
Schools Design Principles and Foundational Technologies
SBA
ASA Connection
Services Block Connection
The ASA firewall connection to the Catalyst 4500 modular switch is fundamentally
different from the other network device connections to this switch-it uses the redundant
interface feature of the ASA. The ASA redundant interface is a logical interface that pairs
two physical interfaces, called active and standby interfaces. Under normal operation, the
active interface is the only one passing traffic. The active interface uses the IP address
defined at the redundant interface, and the MAC address of the first physical interface
associated with the redundant interface. When the active interface fails, the standby
interface becomes active and starts passing traffic. The same IP address and MAC
address are maintained so that traffic is not disrupted. See Table 6.
The Services Block supports the centralized servers and services for the district. The
Cisco Catalyst 4500 modular switch connection to the Services Block switch uses
EtherChannel, but in this case the connection between the switches is a Layer-3
connection, allowing the services block switch to keep its VLANs from stack is
fundamentally the same as an access switch connection, with different VLANs.
Table 7 provides sample configurations for the Cisco 4500 modular switch and the
Services Block switch.
Table 6
Example 4500 Modular Switch
Configuration
Example Services Block Switch
Configuration
interface Port-channel17 
description Connected to cr26-3750DC-DO 
switchport 
switchport trunk native vlan 806 
switchport trunk allowed vlan 141-150,900 
switchport mode trunk 
logging event link-status 
load-interval 30 
carrier-delay msec 0 
service-policy output PQ-POLICER
interface Port-channel1 
description Connected to cr24-4507-DO 
switchport trunk encapsulation dot1q 
switchport trunk native vlan 806 
switchport trunk allowed vlan 141-150,900 
switchport mode trunk 
logging event bundle-status 
load-interval 30 
carrier-delay msec 0 
hold-queue 2000 in 
hold-queue 2000 out
interface GigabitEthernet1/1 
description Connected to cr24-2960-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
logging event link-status 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 11 mode desirable 
spanning-tree guard root 
service-policy output EGRESS-POLICY 

! 

interface GigabitEthernet2/1 
description Connected to cr24-2960-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
logging event link-status 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 11 mode desirable 
spanning-tree guard root 
service-policy output EGRESS-POLICY
interface GigabitEthernet0/1 
description Connected to cr24-4507-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan
101-110,201,900 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol pagp 
channel-group 1 mode desirable 
hold-queue 2000 in 
hold-queue 2000 out 
ip dhcp snooping trust 
! 
interface GigabitEthernet0/2 
description Connected to cr24-4507-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan
101-110,201,900 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol pagp 
channel-group 1 mode desirable 
hold-queue 2000 in 
hold-queue 2000 out 
ip dhcp snooping trust
ASA Connection Configuration
Example Catalyst 4500 Modular
Switch Configuration
interface GigabitEthernet4/4 
description backup link to
cr26-asa5520-DO
switchport access vlan 200
switchport mode access
switchport block unicast
load-interval 30
spanning-tree portfast
spanning-tree bpduguard enable
service-policy output EGRESS-POLICY 
! 
interface GigabitEthernet5/3 
description Connected to
cr26-asa5520-DO
switchport access vlan 200
switchport mode access
switchport block unicast
load-interval 30
media-type rj45
spanning-tree portfast
spanning-tree bpduguard enable
service-policy output EGRESS-POLICY 
!
interface Vlan200 
description cr24_4507_FW_Inside 
ip address 10.125.33.9 255.255.255.0 
ip authentication mode eigrp 100 md5 
ip authentication key-chain eigrp 100
eigrp-key 
ip pim sparse-mode 
ip summary-address eigrp 100
10.125.0.0 255.255.0.0 5 
logging event link-status 
load-interval 30 
carrier-delay msec 0
Example ASA Interface Configuration
interface GigabitEthernet0/0 
description Connected to cr24-4507-DO 
no nameif 
no security-level 
no ip address 
! 
interface GigabitEthernet0/1 
description backup to cr24-4507-DO 
no nameif 
no security-level 
no ip address 
! 
! Defines logical redundant interface associated
with physical interfaces. Configures IP and
logical interface parameters. 
interface Redundant1 
description Connected to cr24-4507-DO 
member-interface GigabitEthernet0/0 
member-interface GigabitEthernet0/1 
nameif inside 
security-level 100 
ip address 10.125.33.10 255.255.255.0 
authentication key eigrp 100 <removed> key-id 1 
authentication mode eigrp 100 md5 
Table 7
Service Block Configuration
Schools Design Principles and Foundational Technologies
SBA
Core/Distribution Virtual Interfaces
The following is an example configuration of the Switch Virtual Interfaces configured on
the core/distribution Catalyst 4500 modular switch. This SVIs are trunked to the access
switches as required, and access to the VLANs are controlled by the switchport trunk
allowed vlan command applied on the port channels. The same basic configuration is
used for the Server Switch
interface Vlan101
description Connected to cr24_2960_Dept_1_VLAN
dampening
ip address 10.125.1.1 255.255.255.128
ip helper-address 10.125.31.2
no ip redirects
no ip unreachables
ip pim sparse-mode
load-interval 30
!
...
interface Vlan110
description Connected to cr24_2960_Dept_10_VLAN
dampening
ip address 10.125.5.129 255.255.255.128
ip helper-address 10.125.31.2
no ip redirects
no ip unreachables
ip pim sparse-mode
load-interval 30
Table 8 provides examples of the port-channel configuration on core/distribution Catalyst
4500 modular switch and an access switch. A similar configuration would be applied to
each access switch connection with the same or different VLANs as required. From an IP
routing or services level there is no requirement to span the same VLAN to multiple
switches, but if there is a requirement to support legacy protocols such as AppleTalk at the
school these AppleTalk VLANs can be easily spanned to different access switches as
required.
Table 8
Core/Distribution Virtual Interfaces
Example 4500 Modular switch Port Channel
Configuration
Example 2960 Port Channel
Configuration
Example 4500 Modular switch Port Channel
Example 2960 Port Channel
Configuration
Configuration
interface Port-channel11 
description Connected to cr24-2960-DO 
switchport 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
logging event link-status 
load-interval 30 
carrier-delay msec 0 
service-policy output PQ-POLICER
interface Port-channel1 
description Connected to cr24-4507-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan
101-110,201,900 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
carrier-delay msec 0 
hold-queue 2000 in 
hold-queue 2000 out 
ip dhcp snooping trust
interface GigabitEthernet1/1 
description Connected to cr24-2960-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
logging event link-status 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 11 mode desirable 
spanning-tree guard root 
service-policy output EGRESS-POLICY 

interface GigabitEthernet2/1 
description Connected to cr24-2960-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan 101-110,900 
switchport mode trunk 
logging event link-status 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 11 mode desirable 
spanning-tree guard root 
service-policy output EGRESS-POLICY 
interface GigabitEthernet0/1 
description Connected to cr24-4507-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan
101-110,201,900 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol pagp 
channel-group 1 mode desirable 
hold-queue 2000 in 
hold-queue 2000 out 
ip dhcp snooping trust 
! 
interface GigabitEthernet0/2 
description Connected to cr24-4507-DO 
switchport trunk native vlan 802 
switchport trunk allowed vlan
101-110,201,900 
switchport mode trunk 
ip arp inspection trust 
load-interval 30 
srr-queue bandwidth share 1 30 35 5 
priority-queue out 
udld port 
mls qos trust dscp 
channel-protocol pagp 
channel-group 1 mode desirable 
hold-queue 2000 in 
hold-queue 2000 out 
ip dhcp snooping trust
Schools Design Principles and Foundational Technologies
SBA
WLC Connection
NAC CAS Connection
The WLC Connection to the Core/Distribution Stack is fundamentally the same as an
Access Switch connection, with different VLANs, and the exception of using a different
QoS trust mode, where the CoS values from the WLC, are trusted. The following is an
example of the configuration.
The NAC CAS connection to the core/distribution switch. This is not an EtherChannel
connection, but two switch ports are consumed. The two ports consist of a untrusted port
for connecting client VLANs to the CAS prior to them completing the NAC process, and a
trusted port that connects the NAS to the client VLANs used once clients have
successfully completed the NAC process. The two, trusted and untrusted, ports are
required even if OOB NAC is used, as the CAS requires access to the trusted VLANs
during the NAC process. The following is an example of the configuration
Interface Port-channel12
description Connected to WLC-SS2
switchport trunk encapsulation dot1q
switchport trunk native vlan 802
switchport trunk allowed vlan 111-120
.
interface GigabitEthernet 3/9
description NAC Trusted Eth0
switchport mode trunk
switchport trunk encapsulation dot1q
load-interval 30
switchport trunk allowed vlan 48,57,62
carrier-delay msec 0
switchport mode trunk
ip dhcp snooping trust
spanning-tree portfast trunk
interface GigabitEthernet1/0/48
description Connected to WLC-SS2
switchport trunk encapsulation dot1q
switchport trunk native vlan 802
switchport trunk allowed vlan 110-120
switchport mode trunk
load-interval 30
carrier-delay msec 0
!
interface GigabitEthernet 4/9
description NAC Untrusted Eth1
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 61,248,257
switchport mode trunk
spanning-tree portfast trunk
SRST Connection
srr-queue bandwidth share 1 30 35 5
priority-queue out
udld port
mls qos trust coschannel-group 11 mode active
spanning-tree guard root
!
interface GigabitEthernet3/0/48
The SRST connection to the core/distribution is another EtherChannel connection. The
differences between the SRST connection and the access switch connections are that a
trunk connection is not required, and that the SRST interfaces are router interfaces,
requiring a slightly different connection. Table 9 provides an example of the configuration.
Table 9
SRST Connection
description Connected to WLC-SS2
Core/Distribution
ISR Routers
switchport trunk encapsulation dot1q
interface Port-channel1 
description Connected to ISR …!

interface GigabitEthernet3/10 
no switchport 
no ip address 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 1 mode desirable 
service-policy output EGRESS-POLICY 
! 
interface GigabitEthernet4/10 
no switchport 
no ip address 
load-interval 30 
carrier-delay msec 0 
udld port 
channel-protocol pagp 
channel-group 1 mode desirable 
service-policy output EGRESS-POLICY
interface Port-channel3 
description port-channel to 4500 …
! 
interface GigabitEthernet0/0 
description
$ETH-LAN$$ETH-SW-LAUNCH$$INTF-INFO-GE 0/0$ 
no ip address 
duplex auto 
speed auto 
media-type rj45 
no keepalive 
channel-group 3 
! 
interface GigabitEthernet0/1 
no ip address 
duplex auto 
speed auto 
media-type rj45 
no keepalive 
channel-group 3
switchport trunk native vlan 802
switchport trunk allowed vlan 110-110,
switchport mode trunk
load-interval 30
carrier-delay msec 0
srr-queue bandwidth share 1 30 35 5
priority-queue out
udld port
mls qos trust coschannel-group 11 mode active
spanning-tree guard root
Schools Design Principles and Foundational Technologies
Figure 33
NTP School District Hierarchy
The use of Network Time Protocol (NTP) to synchronize the clocks of network devices is a
well established best practice, is fundamental for the analysis of logs/events and security,
but might not warrant a mention in a design guide that is focused upon introducing new
designs and practices to support new services in the network.
Given that a number of key components (for example, CUWN and Cisco NAC) of the
Schools SRA rely upon or benefit from time synchronization, it was decided to include a
short discussion on Time Synchronization as part of the Schools SRA.
The preferred mechanism for time synchronization in the network is NTP (other systems
may use their own time synchronization mechanism) and this network NTP discussion is
not proposed as a the design to synchronize all devices (hosts) in the network, its goal is
synchronization of the network components of the Schools SRA. At the same time,
whatever alternative times synchronization systems used in other parts of the network
need to have agreement on the time, and should have a common time source at the
beginning of their timing hierarchy. This will allow sufficient synchronization between
hosts and network devices for the solutions deployed in the SRA.
The Schools SRA network has a hierarchy based upon the district office, as hub, and the
schools as spokes. The NTP hierarchy should be the same, with the highest stratum NTP
server located at the district office serving as the time reference for the district network. In
order to spread the load, a hierarchy of NTP servers is used. The district office NTP server
acting as the server for the district office network devices, and for the NTP server at each
school, and the NTP Server for each school will act as the NTP server for network devices
in that school.
The preferred network device to act as the NTP server in the schools SRA is the ISR router
at each site. The ISR is the preferred device as routers have a greater CPU capacity than
switches used in the Schools SRA due to many of the general purpose task that a router
may be required it perform in CPU, compared to switches that have been more optimized
to perform their more limited number of tasks in ASIC.
Figure 33 shows a schematic of the NTP hierarchy in the school district.
For more information about NTP, refer to the Network Time Protocol: Best Practices White
Paper at the following URL:
http://www.cisco.com/en/US/tech/tk869/tk769/technologies_white_paper09186a0080
117070.shtml
CAS
School 1
NTP
V
WLC
SRST
District Office
ME
Metro
Ethernet
Switch
NTP
Server
Switch
CAS
Access
Switch
Access
Switch
V
SRST
MAN
Internet
ASA
Firewall
Access
Switch
WLC
Distribution
Switch
Access
Switch
Services Block
Switch
School 2
CAS
NTP
V
WLC
SRST
Server
Switch
Access
Switch
Access
Switch
227528
NTP
SBA
When creating the NTP configuration care should be taken to protect the NTP system.
The NTP associations should be limited, and controlled by an access list, to protect
against DoS attacks. The NTP system should also use NTP authentication, where possible,
to protected against spoofing attacks.
DO-ISR NTP
School1-ISR
access-list 99 permit x.x.x.x 0.0.0.255 
access-list 99 permit y.y.y.y 0.0.0.255 
ntp authentication-key 2 md5 Riewoldt 
ntp authenticate 
ntp source Port-channel3 
ntp max-associations 150 
ntp server a.a.a.a 
ntp access-group serve-only 99 
access-list 98 permit z.z.z.z 0.0.0.255 
ntp authentication-key 2 md5 Riewoldt 
ntp trusted-key 2 
ntp clock-period 17179685 
ntp max-associations 150 
ntp server <DO-ISR> key 2 
ntp access-group serve-only 98 
Schools Design Principles and Foundational Technologies
SBA