Motherboard Z9PE-D8 WS E8726 Revised Edition V4 October 2013 Copyright © 2013 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”). Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing. ASUS PROVIDES THIS MANUAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL OR PRODUCT. SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ASUS. ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners’ benefit, without intent to infringe. ii Contents Notices........................................................................................................ viii Federal Communications Commission Statement........................... viii Canadian Department of Communications Statement..................... viii REACH viii Safety information....................................................................................... ix Electrical safety..................................................................................ix Operation safety.................................................................................ix About this guide........................................................................................... x How this guide is organized................................................................x Where to find more information...........................................................x Conventions used in this guide..........................................................xi Typography........................................................................................xi Z9PE-D8 WS specifications summary...................................................... xii Chapter 1: Product introduction 1.1 Welcome!....................................................................................... 1-3 1.3 Serial number label....................................................................... 1-4 1.2 1.4 Package contents.......................................................................... 1-3 Special features............................................................................. 1-4 1.4.1 1.4.2 Chapter 2: 2.1 2.2 2.4 2.5 Innovative ASUS features................................................ 1-6 Hardware information Before you proceed...................................................................... 2-3 Motherboard overview.................................................................. 2-4 2.2.1 Placement direction......................................................... 2-4 2.2.3 Motherboard layout.......................................................... 2-5 2.2.2 2.3 Product highlights............................................................ 1-4 2.2.4 Screw holes..................................................................... 2-4 Layout contents................................................................ 2-6 Central Processing Unit (CPU).................................................... 2-8 2.3.1 Installing the CPU............................................................ 2-8 2.4.1 Overview........................................................................ 2-13 System memory.......................................................................... 2-13 2.4.2 Memory Configurations.................................................. 2-13 Expansion slots........................................................................... 2-16 2.5.1 Installing an expansion card.......................................... 2-16 iii Contents 2.5.2 Configuring an expansion card...................................... 2-16 2.5.4 PCI Express x16 slot (x16 link)...................................... 2-18 2.5.3 2.5.5 2.6 2.7 2.8 2.9 2.5.6 Jumpers....................................................................................... 2-26 Connectors.................................................................................. 2-29 2.9.1 3.2.1 Using the OS shut down function..................................... 3-4 Using the dual function power switch............................... 3-4 BIOS setup 4.1.1 ASUS CrashFree BIOS 3................................................. 4-3 4.1.3 BUPDATER . ................................................................... 4-5 ASUS EZ Flash 2 . .......................................................... 4-4 BIOS setup program..................................................................... 4-7 4.2.1 BIOS menu screen........................................................... 4-8 4.2.3 Menu items...................................................................... 4-9 4.2.2 4.2.4 4.2.5 4.2.6 4.2.7 4.2.8 4.2.9 Menu bar.......................................................................... 4-8 Submenu items................................................................ 4-9 Navigation keys................................................................ 4-9 General help.................................................................... 4-9 Configuration fields.......................................................... 4-9 Pop-up window................................................................ 4-9 Scroll bar.......................................................................... 4-9 Main menu................................................................................... 4-10 4.3.1 4.3.2 iv Powering up Managing and updating your BIOS............................................. 4-3 4.1.2 4.3 Internal connectors........................................................ 2-31 Powering off the computer........................................................... 3-4 Chapter 4: 4.2 Rear panel connectors................................................... 2-29 Starting up for the first time......................................................... 3-3 3.2.2 4.1 Installing the ASMB6 management board...................... 2-19 Onboard LEDs............................................................................. 2-21 Chapter 3: 3.2 PCI Express x16 slot (x8 link)........................................ 2-18 Onboard Switches....................................................................... 2-20 2.9.2 3.1 Interrupt assignments.................................................... 2-17 System Date.................................................................. 4-10 System Time.................................................................. 4-10 Contents 4.4 Ai Tweaker menu......................................................................... 4-11 4.5 Advanced menu.......................................................................... 4-15 4.4.1 DRAM Timing Control ................................................... 4-13 4.5.1 CPU Configuration......................................................... 4-15 4.5.3 Chipset Configuration.................................................... 4-20 4.5.2 4.5.4 4.5.5 4.5.6 4.5.7 4.5.8 4.5.9 4.5.10 4.5.11 4.5.12 4.5.13 4.5.14 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.5.15 PCH SATA Configuration............................................... 4-26 PCH SCU Configuration................................................ 4-27 PCI Subsystem Settings................................................ 4-28 USB Configuration......................................................... 4-31 ACPI Settings................................................................. 4-33 WHEA Configuration...................................................... 4-33 APM setting.................................................................... 4-34 Serial Port Console Redirection..................................... 4-35 Onboard LAN Configuration........................................... 4-37 Marvell SATA Configuration........................................... 4-38 Onboard Devices Configuration..................................... 4-39 Runtime Error Logging................................................... 4-40 Server Management menu......................................................... 4-41 4.6.1 4.6.2 System Event Log.......................................................... 4-42 BMC network configuration............................................ 4-43 Event Logs menu........................................................................ 4-44 4.7.1 Change Smbios Event Log Settings.............................. 4-45 Boot menu................................................................................... 4-47 Monitor menu.............................................................................. 4-50 Security menu............................................................................. 4-52 Tool menu.................................................................................... 4-53 Exit menu..................................................................................... 4-54 Chapter 5: 5.1 CPU Power Management Configuration........................ 4-18 RAID configuration Setting up RAID............................................................................. 5-3 5.1.1 RAID definitions............................................................... 5-3 5.1.3 Setting the RAID item in BIOS......................................... 5-4 5.1.2 5.1.4 Installing hard disk drives................................................. 5-4 RAID configuration utilities............................................... 5-4 5.2LSI Software RAID Configuration Utility .................................... 5-5 Contents 5.2.1 Creating a RAID set......................................................... 5-6 5.2.3 Initializing the virtual drives............................................ 5-13 5.2.2 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 Adding or viewing a RAID configuration........................ 5-12 Rebuilding failed drives.................................................. 5-17 Checking the drives for data consistency...................... 5-19 Deleting a RAID configuration........................................ 5-22 Selecting the boot drive from a RAID set....................... 5-23 Enabling WriteCache..................................................... 5-24 5.3Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM Utility...................................................................... 5-25 5.3.1 Creating a RAID set....................................................... 5-27 5.3.3 Deleting a RAID set....................................................... 5-30 5.3.2 5.3.4 5.3.5 5.3.6 5.3.7 Creating a Recovery set................................................ 5-28 Resetting disks to Non-RAID......................................... 5-31 Exiting the Intel® Rapid Storage Technology utility......... 5-31 Rebuilding the RAID...................................................... 5-32 Setting the Boot array in the BIOS Setup Utility............. 5-34 5.4Intel Rapid Storage Technology enterprise Utility (Windows)5-35 ® 5.4.1 Creating a RAID set....................................................... 5-36 5.4.3 Delete volume................................................................ 5-39 5.4.2 5.5 5.4.4 Preferences.................................................................... 5-40 Marvell RAID utility..................................................................... 5-41 5.5.1 5.5.2 Chapter 6: 6.1 Change Volume Type..................................................... 5-38 Create a RAID Array...................................................... 5-41 Delete an existing RAID Array....................................... 5-43 Driver installation RAID driver installation................................................................ 6-3 6.1.1 6.1.2 Creating a RAID driver disk............................................. 6-3 Installing the RAID controller driver................................. 6-5 6.2Intel Chipset Device Software installation.............................. 6-14 ® 6.3Intel@ Network Connections Software installation.................. 6-16 6.4 Audio driver installation............................................................. 6-19 installation................................................................................... 6-21 6.5Intel® C600 Series Chipset SCU SATA RAID Drivers 6.6 vi Marvell Magni installation.......................................................... 6-22 6.7Intel® Rapid Storage Technology enterprise 3.0 installation.. 6-23 6.8Marvell Storage Utility installation............................................ 6-26 6.9Asmedia ASM104x USB 3.0 Host Controller Driver installation................................................................................... 6-30 6.11 VGA driver installation............................................................... 6-36 6.10Intel® WG82574L Gigabit Adapters Driver installation............. 6-33 6.12Management applications and utilities installation................. 6-39 6.12.1 Running the support DVD.............................................. 6-39 6.12.3 Utilities menu................................................................. 6-40 6.12.2 Drivers menu.................................................................. 6-39 6.12.4 Make disk menu............................................................. 6-40 6.12.5 Contact information........................................................ 6-40 Chapter 7: 7.1 Multiple GPU technology support AMD® CrossFireX™ technology.................................................. 7-3 7.1.1 Requirements................................................................... 7-3 7.1.3 Installing two CrossFireX™ graphics cards..................... 7-4 7.1.5 Enabling the AMD® CrossFireX™ technology.................. 7-5 7.1.2 Before you begin.............................................................. 7-3 7.1.4 7.2 Installing the device drivers.............................................. 7-5 NVIDIA® SLI™ technology............................................................ 7-7 7.2.1 Requirements................................................................... 7-7 7.2.3 Installing three SLI-ready graphics cards......................... 7-8 7.2.2 Installing two SLI-ready graphics cards........................... 7-7 7.2.4 Installing four SLI-ready graphics cards........................... 7-9 7.2.5 7.3 7.2.6 Enabling the NVIDIA® SLI™ technology........................ 7-10 NVIDIA CUDA™ technology..................................................... 7-13 7.3.1 7.3.2 Appendix: A.1 Installing the device drivers............................................ 7-10 ® Requirements................................................................. 7-13 Installing CUDA-ready graphics cards........................... 7-13 Reference information Z9PE-D8 WS block diagram.........................................................A-3 vii Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • • This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturer’s instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. • • Increase the separation between the equipment and receiver. Consult the dealer or an experienced radio/TV technician for help. The use of shielded cables for connection of the monitor to the graphics card is required to assure compliance with FCC regulations. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. Canadian Department of Communications Statement This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. This class B digital apparatus complies with Canadian ICES-003. REACH Complying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we publish the chemical substances in our products at ASUS REACH website at http://csr.asus.com/english/REACH.htm. viii Safety information Electrical safety • • • • • • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding or removing devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device. Before connecting or removing signal cables from the motherboard, ensure that all power cables are unplugged. Seek professional assistance before using an adapter or extension cord. These devices could interrupt the grounding circuit. Make sure that your power supply is set to the correct voltage in your area. If you are not sure about the voltage of the electrical outlet you are using, contact your local power company. If the power supply is broken, do not try to fix it by yourself. Contact a qualified service technician or your retailer. Operation safety • • • • • • Before installing the motherboard and adding devices on it, carefully read all the manuals that came with the package. Before using the product, make sure all cables are correctly connected and the power cables are not damaged. If you detect any damage, contact your dealer immediately. To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry. Avoid dust, humidity, and temperature extremes. Do not place the product in any area where it may become wet. Place the product on a stable surface. If you encounter technical problems with the product, contact a qualified service technician or your retailer. DO NOT throw the motherboard in municipal waste. This product has been designed to enable proper reuse of parts and recycling. This symbol of the crossed out wheeled bin indicates that the product (electrical and electronic equipment) should not be placed in municipal waste. Check local regulations for disposal of electronic products. DO NOT throw the mercury-containing button cell battery in municipal waste. This symbol of the crossed out wheeled bin indicates that the battery should not be placed in municipal waste. ix About this guide This user guide contains the information you need when installing and configuring the motherboard. How this guide is organized This user guide contains the following parts: • • • • • • • Chapter 1: Product introduction This chapter describes the features of the motherboard and the new technologies it supports. Chapter 2: Hardware information This chapter lists the hardware setup procedures that you have to perform when installing system components. It includes description of the switches, jumpers, and connectors on the motherboard. Chapter 3: Powering up This chapter describes the power up sequence and ways of shutting down the system. Chapter 4: BIOS setup This chapter tells how to change system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided. Chapter 5: RAID configuration This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities. Chapter 6: Driver installation This chapter provides instructions for installing the necessary drivers for different system components. Appendix: Reference information This appendix includes additional information that you may refer to when configuring the motherboard. Where to find more information Refer to the following sources for additional information and for product and software updates. 1. 2. ASUS websites The ASUS website provides updated information on ASUS hardware and software products. Refer to the ASUS contact information. Optional documentation Your product package may include optional documentation, such as warranty flyers, that may have been added by your dealer. These documents are not part of the standard package. Conventions used in this guide To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task. Typography Bold text Italics Indicates a menu or an item to select. Used to emphasize a word or a phrase. <Key> Keys enclosed in the less-than and greaterthan sign means that you must press the enclosed key. Example: <Enter> means that you must press the Enter or Return key. <Key1+Key2+Key3> If you must press two or more keys simultaneously, the key names are linked with a plus sign (+). Example: <Ctrl+Alt+Del> Command Means that you must type the command exactly as shown, then supply the required item or value enclosed in brackets. Example: At the DOS prompt, type the command line: format A:/S xi Z9PE-D8 WS specifications summary CPU Chipset Memory Dual Intel® Socket 2011 for Xeon® processor E5-2600 product family Supports Intel® Turbo Boost Technology 2.0 QPI 6.4/7.2/8.0 GTs *Refer to www.asus.com for CPU support list Intel® C602 Express Chipset 8 x DIMM, Max. 256GB DDR3 1600/1333/1066/800 MHz, Registered Memory; Max. 64GB, DDR3 2133(O.C.)/ 2000(O.C.)/1866(O.C.)/1600/1333/1066 MHz, ECC, Non-ECC, un-buffered Memory Quad channel memory architecture Expansion slots *Refer to www.asus.com for the memory QVL (Qualified Vendors Lists). 4 x PCIe 3.0 x16 slots (Dual@x16/x16; Quad@x8/x8/x8/ x8) 2 x PCIe 3.0 x16 slots (@x16 speed) 1 x PCIe 3.0 x16 slot (@x8 speed) VGA Output Multi-GPU support Storage LAN Audio * This motherboard is ready to support PCIe 3.0 SPEC. Functions will be available when using PCIe 3.0-compliant devices. Please refer to www.asus.com for updated details. ASpeed AST2300 16MB VGA port (with bracket) Supports VGA with max. resolution 1920 x 1200@60Hz Supports NVIDIA® 4-Way SLI™ Technology Supports AMD® Quad-GPU CrossFireX™ Technology Intel® C602 Chipset: - 2 x SATA 6Gb/s ports with RAID 0,1,5 and 10 support (for Windows only) (AHCI) - 4 x SATA 3Gb/s ports with RAID 0,1,5 and 10 support (for Windows only) (AHCI) - 4 x SATA 3Gb/s ports with RAID 0,1,5 and 10 support (for Windows only) (SCU) Marvell® 9230 SATA controller: - 4 x SATA 6Gb/s ports (RAID 0, 1, 10 for Windows only) 2*Intel® 82574L Gigabit LAN controller Realtek® ALC 898 8-channel High Definition Audio CODEC - Supports 192kHz/ 24bit BD Lossless Sound - DTS Surround Sensation UltraPC II - Supports Jack-Detection, Multi-Streaming, and Front Panel Jack-Retasking - Optical S/PDIF Out port at back I/O (continues on next page) xii Z9PE-D8 WS specifications summary USB ASUS Unique Features Workstation Unique Features Back Panel I/O Ports ASMedia USB 3.0 controllers - 2 x USB 3.0/2.0 ports at mid-board for front panel support - 2 x USB 3.0/2.0 ports at back panel Intel®C602 Chipset - 12 x USB 2.0/1.1 ports (6 ports at mid-board, 6 ports at back panel) CPU Power - Digital 7+1 Phase Power Design DRAM Power - Digital 2 Phase Power Design ASUS Exclusive Features - ASUS SSD Caching - Front Panel USB 3.0 Support ASUS Quiet Thermal Solution - ASUS Fanless Design: Heat pipe solution ASUS Q-Design - ASUS Q-Code - ASUS Q-Shield - ASUS Q-Slot - ASUS Q-DIMM ASUS EZ DIY - ASUS CrashFree BIOS 3 - ASUS EZ Flash 2 - ASUS MyLogo 2 - Multi-language BIOS - 7 PCIe x 16 slots - Quick Gate:2 vertical USB 2.0 on board - ASWM Enterprise - ASMB6-iKVM Remote Management Tool 2 x USB 3.0/2.0 ports (blue) 6 x USB 2.0/1.1 ports 1 x PS/2 KB port 2 x LAN (RJ45) ports (2 x Intel® LAN) 1 x Optical S/PDIF Out port 8-channel Audio I/O (continues on next page) xiii Z9PE-D8 WS specifications summary Internal I/O Connectors BIOS Features Manageability Accessories Support DVD Form Factors 1 x USB 3.0/2.0 connector support additional 2 USB ports (19-pin) 2 x USB 2.0/1/1 connectors support additional 4 USB ports 2 x USB 2.0/1.1 type A vertical ports 6 x SATA 6Gb/s connectors 8 x SATA 3Gb/s connectors 2 x CPU Fan connector (4-pin) 6 x Chassis Fan connectors (4-pin) 2 x IEEE1394a headers 2 x Serial Port headers 1 x RAID key header 1 x ASMB6-iKVM connector 1 x VGA connector 1 x Front panel audio connector(AAFP) 1 x AUX panel header 1 x SMBus headers 1 x S/PDIF Out header 1 x Clear CMOS header 1 x 24-pin EATX Power connector 2 x 8-pin EATX 12V Power connectors 1 x 4-pin EZ_PLUG Power connector(s) 1 x System Panel 1 x PWR button 1 x Reset button 64 Mb Flash ROM, UEFI BIOS, PnP, DMI2.0, WfM2.0, SM BIOS 2.6, ACPI 2.0a, Multi-language BIOS, ASUS EZ Flash 2, ASUS CrashFree BIOS 3 WfM 2.0, DMI 2.0, WOL by PME, WOR by PME, PXE 6 x Serial ATA 6Gb/s cables 8 x Serial ATA 3Gb/s cables 1 x ASUS 4-Way SLI bridge connector 1 x ASUS 3-Way SLI bridge connector 1 x ASUS SLI bridge connector 1 x 2-port USB2.0 + 1394 bracket 2 x COM port bracket I/O Shield User’s manual Drivers ASUS Utilities ASUS Update EEB Form Factor, 12”x 13” *Refer to ASUS Server AVL for latest update. **Specifications are subject to change without notice. xiv This chapter describes the motherboard features and the new technologies it supports. 1 Product introduction Chapter summary 1 1.1 Welcome!....................................................................................... 1-3 1.3 Serial number label....................................................................... 1-4 1.2 1.4 Package contents.......................................................................... 1-3 Special features............................................................................. 1-4 ASUS Z9PE-D8 WS 1.1 Welcome! Thank you for buying an ASUS® Z9PE-D8 WS motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of ASUS quality motherboards! Before you start installing the motherboard, and hardware devices on it, check the items in your package with the list below. 1.2 Package contents Check your motherboard package for the following items. Z9PE-D8 WS Cables I/O Modules Accessories SATA DOM cable SATA 6G cable SATA 3G cable COM port cable 2-port USB 2.0+1394a IO shield Standard Gift Box Pack 1 6 8 2 1 1 Standard Bulk Pack -----1 2-Way SLI Bridge connector 1 -- 3-Way SLI Bridge connector 1 -- 4-Wat SLI Bridge connector 1 -- 2 1 2 1 Application CD Support CD Documentation User Guide Packing Qty. 1 or 3pcs per carton 5pcs per carton If any of the above items is damaged or missing, contact your retailer. ASUS Z9PE-D8 WS 1-3 1.3 Serial number label Before requesting support from the ASUS Technical Support team, you must take note of the motherboard's serial number containing 12 characters xxS1xxxxxxxx shown as the figure below. With the correct serial number of the product, ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems. Z9PE-D8 WS xxS1xxxxxxxx 1.4 Special features 1.4.1 Product highlights Made in Taiwan 合格 Latest Processor Technology The motherboard supports the latest Intel Xeon® processor E5-2600 product family in LGA 2011 package with integrated memory controller to support 4 channel (4DIMM per CPU) DDR3 memory. Intel Xeon® processor E5-2600 product family supports Intel QuickPath Interconnect (QPI) with a system bus of up to 8.0GT/s. Optimized Intel® Turbo Boost Technology Optimized Intel® Turbo Boost Technology further optimizes the processor’s performance and automatically allows it to run faster than the marked frequency if it is operating below power, temperature, and current limits. Intel® Hyper Threading The thread-level parallelism on each processor makes more efficient use of the processor resources, higher processing throughout, and improved performance on today's multi-threaded software. Intel® EM64T The motherboard supports Intel® processors with the Intel® EM64T (Extended Memory 64 Technology). The Intel® EM64T feature allows your computer to run on 64-bit operating systems and access larger amounts of system memory for faster and more efficient computing. 1-4 Chapter 1: Product introduction DDR3 memory support The motherboard supports the 4-channel DDR3 memory that features data transfer rates of DDR3 1600 / 1333 / 1066 MHz to boost the system’s performance, and to meet the higher bandwidth requirements of server and workstation applications. The 4-channel DDR3 architecture also manages traffic with bandwidth of up to 52GB/s, and reduces voltage thus reducing power usage and heat generation. Also, the motherboard supports LR-DIMM (Load reduced DIMM) which uses a specially designed buffer to reduce the data load to a single load and can increase overall server system memory capacity. PCI Express® 3.0 PCI Express® 3.0 (PCIe 3.0) is the PCI Express bus standard that provides twice the performance and speed of PCIe 2.0. It provides an optimal graphics performance, unprecedented data speed, and seamless transition with its complete backward compatibility to PCIe 1.0/2.0 devices. Intel® 82574L Gigabit LAN Solution This motherboard features the built-in dual server class Intel® Gigabit LAN ports, which helps reduce CPU usage, thus increasing throughput to achieve highly-reliable network connections, outstanding performance, and better support for diverse operating systems. Intel® 82574L chipset is VMware-certified to support the virtualization technology. Enhanced Intel SpeedStep Technology (EIST) The Enhanced Intel SpeedStep Technology (EIST) intelligently manages the CPU resources by automatically adjusting the CPU voltage and core frequency depending on the CPU loading and system speed or power requirement. Serial ATA II technology The motherboard supports the Serial ATA II 3 Gb/s technology through the Serial ATA interface and Intel® C602 chipset. The Serial ATA II specification provides twice the bandwidth of the current Serial ATA products with a host of new features, including Native Command Queuing (NCQ), Power Management (PM) Implementation Algorithm, and Hot Swap. Serial ATA allows thinner, more flexible cables with lower pin count and reduced voltage requirements. ASUS Z9PE-D8 WS 1-5 Serial ATA III technology The motherboard supports the Serial ATA III technology through the Serial ATA interface and Intel® C602 chipset, delivering up to 6Gb/s data transfer rates. Additionally, get enhanced scalability, faster data retrieval, double the bandwidth of current bus systems. Extra SATA 6.0 Gb/s Support The Intel® C602 Express Chipset natively supports the next-generation Serial ATA (SATA) interface, delivering up to 6.0 Gb/s data transfer. ASUS provides extra SATA 6.0 Gb/s ports with enhanced scalability, faster data retrieval, and double the bandwidth of current bus systems. Complete USB 3.0 Integration ASUS facilitates strategic USB 3.0 accessibility for both the front and rear panel – 4USB 3.0 ports in total. Experience the latest plug & play connectivity at speeds up to 10 times faster than USB 2.0. The Z9PE-D8 WS affords greater convenience to high speed connectivity. Temperature, fan, and voltage monitoring The CPU temperature is monitored to prevent overheating and damage. The system fan rotations per minute (RPM) is monitored for timely failure detection. The chip monitors the voltage levels to ensure stable supply of current for critical components. 1.4.2 Innovative ASUS features ASUS Fan Speed control technology The ASUS Fan Speed control technology smartly adjusts the fan speeds according to the system loading to ensure quiet, cool, and efficient operation. Best graphics performance for 4-way NVIDIA® GeForce® SLI™ Native second generation PCI-Expressx16 4-way SLI™ offers the fastest and most reliable graphics performance ever. It's ideal for professional use in mechanical, architectural, interior design, aeronautics, audio and video design applications. Additionally, this ample graphics power can easily run even the most demanding PC games in full detail for enhanced entertainment. Quick Gate Quick Gate is a vertical USB connector on the motherboard, allowing you to install USB devices directly with no messy cables. This stops important data storage devices from breaking off unexpectedly. Z9PE-D8 WS with this unique design provides a convenient and safe way to install data and applications on your PC. 1-6 Chapter 1: Product introduction ASUS SSD Caching SSD caching from ASUS is easier than ever. At 3X faster, this feature boosts system performance by using an installed SSD with no capacity limitations as a cache for frequently accessed data. Harness a combination of SSD-like performance and response and hard drive capacity with just one click, no rebooting needed and instant activation for complete ease of use. ASUS Z9PE-D8 WS 1-7 1-8 Chapter 1: Product introduction This chapter lists the hardware setup procedures that you have to perform when installing system components. It includes description of the jumpers and connectors on the motherboard. Chapter 2: 2 Hardware information Chapter summary 2 2.1 Before you proceed...................................................................... 2-3 2.3 Central Processing Unit (CPU).................................................... 2-8 2.2 2.4 2.5 2.6 2.7 2.8 2.9 Motherboard overview.................................................................. 2-4 System memory.......................................................................... 2-13 Expansion slots........................................................................... 2-16 Onboard Switches....................................................................... 2-20 Onboard LEDs............................................................................. 2-21 Jumpers....................................................................................... 2-26 Connectors.................................................................................. 2-29 ASUS Z9PE-D8 WS 2.1 Before you proceed Take note of the following precautions before you install motherboard components or change any motherboard settings. • Unplug the power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity. • Hold components by the edges to avoid touching the ICs on them. • Whenever you uninstall any component, place it on a grounded antistatic pad or in the bag that came with the component. • Before you install or remove any component, ensure that the power supply is switched off or the power cord is detached from the power supply. Failure to do so may cause severe damage to the motherboard, peripherals, and/or components. ASUS Z9PE-D8 WS 2-3 2.2 Motherboard overview Before you install the motherboard, study the configuration of your chassis to ensure that the motherboard fits into it. To optimize the motherboard features, we highly recommend that you install it in an EEB compliant chassis. Ensure to unplug the chassis power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage motherboard components! 2.2.1 Placement direction When installing the motherboard, ensure that you place it into the chassis in the correct orientation. The edge with external ports goes to the rear part of the chassis as indicated in the image below. 2.2.2 Screw holes Place ten (10) screws into the holes indicated by circles to secure the motherboard to the chassis. DO NOT overtighten the screws! Doing so can damage the motherboard. Place this side towards the rear of the chassis 2-4 Chapter 2: Hardware information 2.2.3 Motherboard layout Z9PE-D8 WS ASUS Z9PE-D8 WS 2-5 2.2.4 Layout contents Slots/Socket Page 2. 2-13 1. CPU sockets 3. PCI Express x8 / PCI Express x16 slots 2-8 DDR3 sockets 2-16 Onboard Switches 1. Power-on Switch Page 2. Reset Switch 2-20 2-20 Onboard LEDs 1. DIMM Error LED (ERR_DIMM) Page 2. Baseboard Management Controller LED (BMC_LED1) 3. Q-Code LED (LED1_LED2) 2-21 2-22 Jumpers 2-6 2-21 Page 1. Clear RTC RAM (CLRTC1) 2-26 2. VGA controller setting (DIAG_VIEW1) 2-27 3. SMBUS connection setting (TESLA_M_SW) 2-27 4. LSI MegaRAID or Intel RSTe selection jumper (3-pin RAID_SEL1) 2-28 5. ME firmware force recovery setting (3-pin ME_RCVR1) 2-28 Rear panel connectors Page 1. PS/2 mouse and keyboard port 2-29 2. LAN 2 (RJ-45) port 2-29 3. LAN 1 (RJ-45) port 2-29 4. USB 2.0 ports 5 and 6 2-29 5. Optical S/PDIF Out port 2-29 6. USB 2.0 ports 3 and 4 2-29 7. USB 2.0 ports 1 and 2 2-29 8. USB 3.0 ports 1 and 2 2-29 9. Audio I/O ports 2-29 Chapter 2: Hardware information Internal connectors Page 1. 2-31 Hard disk activity LED connector (4-pin HDLED1) 2.USB connectors (10-1 pin USB78, USB910; A-Type USB12/11) 3. USB connectors (USB3_34) 4.CPU, front and rear fan connectors (4-pin CPU_FAN1-2, FRNT_FAN1–4, REAR_FAN1-2) 5. Power supply SMBus Connector (PSUSMB1) 6. Serial port connectors (10-1 pin COM1/COM2) 7.Serial ATA 6.0/3.0 Gb/s connectors (7-pin SATA6G_1-2 [blue]; 7-pin SATA3G_3-6 [black]) 2-31 2-32 2-32 2-33 2-33 2-34 8. Marvell Serial ATA 6.0 Gb/s connectors (7-pin SATA6G_E1/E2/E3/E4 [gray]) 2-35 9. Serial ATA SCU connectors (7-pin SATA_SCU1-4 [black]) 2-36 10.EATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1/ EATX12V2) 11. System panel connector (20-1 pin PANEL1) 12. Auxiliary panel connector (20-2 pin AUX_PANEL1) 13. Digital audio connector (4-1 pin SPDIF_OUT) 14. IEEE 1394a port connectors (10-1 pin IE1394_1/2) 15. VGA connector (VGA_HDR1) 16. Front panel audio connector (10-1 pin AAFP) 17. ASMB6 header (ASMB6) ASUS Z9PE-D8 WS 2-36 2-37 2-38 2-39 2-39 2-40 2-40 2-41 2-7 2.3 Central Processing Unit (CPU) The motherboard comes with a surface mount LGA2011 socket designed for the Intel® Xeon E5-2600 family processor. 2.3.1 • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS will shoulder the cost of repair only if the damage is shipment/transit-related. • Keep the cap after installing the motherboard. ASUS will process Return Merchandise Authorization (RMA) requests only if the motherboard comes with the cap on the LGA2011 socket. • The product warranty does not cover damage to the socket contacts resulting from incorrect CPU installation/removal, or misplacement/loss/ incorrect removal of the PnP cap. Installing the CPU To install a CPU: 1. Locate the CPU socket on the motherboard. Before installing the CPU, ensure that the socket box is facing toward you and the load lever is on your left. 2-8 Chapter 2: Hardware information 2. Press the left load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab. To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU. 3. Slightly lift the load lever in the direction of the arrow. 4. Press the right load lever with your thumb (C), then move it to the right (D) until it is released from the retention tab. Lift the load lever in the direction of the arrow (E). A B Load lever E C D ASUS Z9PE-D8 WS 2-9 5. Push the left load lever (F) to lift the load plate (G). F G 6. Position the CPU over the socket, ensuring that the triangle mark is on the top‑right corner of the socket. Triangle mark The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU! 7. Remove the PnP cap (H) from the CPU socket and close the load plate (I). I H 2-10 Chapter 2: Hardware information 8. Push down the right load lever (J), ensuring that the edge of the load plate is fixed by the lever (K). K J 9. Insert the right load lever under the retention tab. 10. Push down the left load lever (L), and then insert the lever under the retention tab (M). ASUS Z9PE-D8 WS L M 2-11 11. Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with, ensuring that it is spread in an even thin layer. Some heatsinks come with preapplied thermal paste. If so, skip this step. The Thermal Interface Material is toxic and inedible. DO NOT eat it. If it gets into your eyes or touches your skin, wash it off immediately, and seek professional medical help. 12. Connect the CPU fan cable to the connector on the motherboard labeled CPU_FAN1 / CPU_FAN2. DO NOT forget to connect the CPU fan connector! Hardware monitoring errors can occur if you fail to plug this connector. 2-12 Chapter 2: Hardware information 2.4 System memory 2.4.1 Overview The motherboard comes with eight (four DIMM per CPU) Double Data Rate 3 (DDR3) Dual Inline Memory Modules (DIMM) sockets. A DDR3 module has the same physical dimensions as a DDR2 DIMM but is notched differently to prevent installation on a DDR2 DIMM socket. DDR3 modules are developed for better performance with less power consumption. The figure illustrates the location of the DDR3 DIMM sockets: 2.4.2 Memory Configurations You may install 1GB, 2GB, 4GB, 8GB, 16GB and 32GB* RDIMMs or 1GB, 2GB, 4GB and 8GB* with ECC/Non-ECC UDIMMs or 8GB, 16GB and 32GB* LR-DIMMs into the DIMM sockets using the memory configurations in this section. 1 CPU Configuration (must on CPU1) DIMM_A1 DIMM_B1 DIMM_C1 DIMM_D1 X 1 DIMMs X X 2 DIMMs X X X X 4 DIMMs • *Refer to ASUS Server AVL for latest update. • Install the DIMMs starting from slot A1 (CPU1) and E1 (CPU2). • Always install DIMMs with the same CAS latency. For optimum compatibility, it is recommended that you obtain memory modules from the same vendor. ASUS Z9PE-D8 WS 2-13 2 CPU Configuration DIMM_A1 DIMM_B1 DIMM_C1 DIMM_D1 X 1 DIMMs X 2 DIMMs X X 4 DIMMs X X X X 8 DIMMs 2 CPU Configuration DIMM_E1 DIMM_F1 DIMM_G1 DIMM_H1 1 DIMMs X 2 DIMMs X X 4 DIMMs X X X X 8 DIMMs 2-14 Chapter 2: Hardware information 2.4.3 1. 2. Installing a DIMM on a single clip DIMM socket Unlock a DIMM socket by pressing the retaining clip outward. DIMM notch Align a DIMM on the socket such that the notch on the DIMM matches the DIMM slot key on the socket. 1 2 DIMM slot key Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction. DO NOT force a DIMM into a socket in the wrong direction to avoid damaging the DIMM. 3. Hold the DIMM by both of its ends, then insert the DIMM vertically into the socket. Apply force to both ends of the DIMM simultaneously until the retaining clip snaps back into place, and the DIMM cannot be pushed in any further to ensure proper sitting of the DIMM. 3 Locked Retaining Clip Always insert the DIMM into the socket VERTICALLY to prevent DIMM notch damage. • To install two or more DIMMs, refer to the user guide bundled in the motherboard package. • Refer to the user guide for qualified vendor lists of the memory modules. Removing a DIMM from a single clip DIMM socket 1. 2. Press the retaining clip outward to unlock the DIMM. Remove the DIMM from the socket. 2 1 Support the DIMM lightly with your fingers when pressing the retaining clips. The DIMM might get damaged when it flips out with extra force. ASUS Z9PE-D8 WS 2-15 2.5 Expansion slots In the future, you may need to install expansion cards. The following subsections describe the slots and the expansion cards that they support. Ensure to unplug the power cord before adding or removing expansion cards. Failure to do so may cause you physical injury and damage motherboard components. 2.5.1 Installing an expansion card To install an expansion card: 1. 2. 3. 4. 5. 6. Before installing the expansion card, read the documentation that came with it and make the necessary hardware settings for the card. Remove the system unit cover (if your motherboard is already installed in a chassis). Remove the bracket opposite the slot that you intend to use. Keep the screw for later use. Align the card connector with the slot and press firmly until the card is completely seated on the slot. Secure the card to the chassis with the screw you removed earlier. Replace the system cover. 2.5.2 Configuring an expansion card After installing the expansion card, configure it by adjusting the software settings. 1. 2. 3. Turn on the system and change the necessary BIOS settings, if any. See Chapter 4 for information on BIOS setup. Assign an IRQ to the card. Refer to the tables on the next page. Install the software drivers for the expansion card. When using PCI cards on shared slots, ensure that the drivers support “Share IRQ” or that the cards do not need IRQ assignments. Otherwise, conflicts will arise between the two PCI groups, making the system unstable and the card inoperable. 2-16 Chapter 2: Hardware information 2.5.3 Interrupt assignments Standard Interrupt assignments IRQ Priority Standard function 1 2 Keyboard Controller 0 2 3* 4* 5* 6 7* 8 9* 10* 11* 12* 13 14* 15* 1 - 11 12 13 14 15 3 4 5 6 7 8 9 10 System Timer Programmable Interrupt Communications Port (COM2) Communications Port (COM1) -- Floppy Disk Controller -- System CMOS/Real Time Clock ACPI Mode when used IRQ Holder for PCI Steering IRQ Holder for PCI Steering PS/2 Compatible Mouse Port Numeric Data Processor Primary IDE Channel Secondary IDE Channel * These IRQs are usually available for ISA or PCI devices. ASUS Z9PE-D8 WS 2-17 2.5.4 PCI Express x16 slot (x16 link) The onboard PCIE 1 and 3 provide one x16 Gen3 link to CPU1 (Auto switch to x8 link if PCIE 2 and 4 are occupied); The onboard PCIE 5 and 7 provide one x16 Gen3 link to CPU2. These slots support VGA cards and various server class high performance add-on cards. 2.5.5 PCI Express x16 slot (x8 link) The onboard PCIE 6 provides one x8 Gen3 link to CPU2; The onboard PCIE 2 and 4 provide one x8 Gen3 link to CPU1. These slot support VGA Cards and various server class high performance add-on cards. PCIE 1 1 x PCI-E x 16 (Gen3 x16/ x8 link) PCIE 3 1 x PCI-E x 16 (Gen3 x16/ x8 link) PCIE 2 PCIE 4 PCIE 5 PCIE 6 PCIE 7 2-18 1 x PCI-E x 16 (Gen3 x8 link) 1 x PCI-E x 16 (Gen3 x8 link) 1 x PCI-E x 16 (Gen3 x16 link) 1 x PCI-E x 16 (Gen3 x8 link) 1 x PCI-E x 16 (Gen3 x16 link) Chapter 2: Hardware information 2.5.6 Installing the ASMB6 management board Follow the steps below to install an optional ASMB management board on your motherboard. 1. Locate the ASMB6 header on the motherboard. 2. Orient and press the ASMB6 management card in place ASUS Z9PE-D8 WS 2-19 2.6 Onboard Switches Onboard switches allow you to fine-tune performance when working on a bare or open-case system. This is ideal for overclockers and gamers who continually change settings to enhance system performance. 1. 2. 2-20 Power-on switch The motherboard comes with a power-on switch that allows you to power up or wake up the system. The switch also lights up when the system is plugged to a power source indicating that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component. The illustration below shows the location of the onboard poweron switch. Reset switch Press the reset switch to reboot the system. Chapter 2: Hardware information 2.7 1. Onboard LEDs DIMM Error LED (ERR_DIMM) These LEDs light up to indicate an error in its nearby DIMM. Enabled only with ASMB6-i KVM on-board. 2. Baseboard Management Controller LED (BMC_LED1) The BMC LED works with the ASUS ASMB6 management device and indicates its initiation status. When the PSU is plugged and the system is OFF, ASUS ASMB6 management device starts system initiation for about one (1) minute. The BMC LED blinks after system initiation finishes. ASUS Z9PE-D8 WS 2-21 3. Q-Code LEDs The Q-Code LED design provides you the 2-digit display, allowing you to know the system status. Refer to the Q-code table below for details. Q-Code table Code 00 01 02 03 04 06 07 08 09 0A 0B 0C – 0D 0E 0F 10 11 – 14 15 – 18 19 – 1C 2B – 2F 30 2-22 Description Not used Power on. Reset type detection (soft/hard). AP initialization before microcode loading System Agent initialization before microcode loading PCH initialization before microcode loading Microcode loading AP initialization after microcode loading System Agent initialization after microcode loading PCH initialization after microcode loading Initialization after microcode loading Cache initialization Reserved for future AMI SEC error codes Microcode not found Microcode not loaded PEI Core is started Pre-memory CPU initialization is started Pre-memory System Agent initialization is started Pre-memory PCH initialization is started Memory initialization Reserved for ASL (see ASL Status Codes section below) Chapter 2: Hardware information Q-Code table (continued) Code 31 32 – 36 37 – 3A 3B – 3E 4F 50 – 53 54 55 56 57 58 59 5A 5B 5C – 5F E0 E1 E2 E3 E4 – E7 E8 E9 EA EB EC – EF F0 F1 F2 F3 F4 F5 – F7 F8 F9 FA FB – FF 60 61 62 Description Memory Installed CPU post-memory initialization Post-Memory System Agent initialization is started Post-Memory PCH initialization is started DXE IPL is started Memory initialization error. Invalid memory type or incompatible memory speed Unspecified memory initialization error Memory not installed Invalid CPU type or Speed CPU mismatch CPU self test failed or possible CPU cache error CPU micro-code is not found or micro-code update is failed Internal CPU error Reset PPI is not available Reserved for future AMI error codes S3 Resume is stared (S3 Resume PPI is called by the DXE IPL) S3 Boot Script execution Video repost OS S3 wake vector call Reserved for future AMI progress codes S3 Resume Failed S3 Resume PPI not Found S3 Resume Boot Script Error S3 OS Wake Error Reserved for future AMI error codes Recovery condition triggered by firmware (Auto recovery) Recovery condition triggered by user (Forced recovery) Recovery process started Recovery firmware image is found Recovery firmware image is loaded Reserved for future AMI progress codes Recovery PPI is not available Recovery capsule is not found Invalid recovery capsule Reserved for future AMI error codes DXE Core is started NVRAM initialization Installation of the PCH Runtime Services ASUS Z9PE-D8 WS 2-23 Q-Code table (continued) Code 63 – 67 68 69 6A 6B – 6F 70 71 72 73 – 77 78 79 7A – 7F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E – 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB 2-24 Description CPU DXE initialization is started PCI host bridge initialization System Agent DXE initialization is started System Agent DXE SMM initialization is started System Agent DXE initialization (System Agent module specific) PCH DXE initialization is started PCH DXE SMM initialization is started PCH devices initialization PCH DXE Initialization (PCH module specific) ACPI module initialization CSM initialization Reserved for future AMI DXE codes Boot Device Selection (BDS) phase is started Driver connecting is started PCI Bus initialization is started PCI Bus Hot Plug Controller Initialization PCI Bus Enumeration PCI Bus Request Resources PCI Bus Assign Resources Console Output devices connect Console input devices connect Super IO Initialization USB initialization is started USB Reset USB Detect USB Enable Reserved for future AMI codes IDE initialization is started IDE Reset IDE Detect IDE Enable SCSI initialization is started SCSI Reset SCSI Detect SCSI Enable Setup Verifying Password Start of Setup Reserved for ASL (see ASL Status Codes section below) Setup Input Wait Chapter 2: Hardware information Q-Code table (continued) Code AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8– BF D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC Description Reserved for ASL (see ASL Status Codes section below) Ready To Boot event Legacy Boot event Exit Boot Services event Runtime Set Virtual Address MAP Begin Runtime Set Virtual Address MAP End Legacy Option ROM Initialization System Reset USB hot plug PCI bus hot plug Clean-up of NVRAM Configuration Reset (reset of NVRAM settings) Reserved for future AMI codes CPU initialization error System Agent initialization error PCH initialization error Some of the Architectural Protocols are not available PCI resource allocation error. Out of Resources No Space for Legacy Option ROM No Console Output Devices are found No Console Input Devices are found Invalid password Error loading Boot Option (LoadImage returned error) Boot Option is failed (StartImage returned error) Flash update is failed Reset protocol is not available ACPI/ASL Checkpoints Code 0x01 0x02 0x03 0x04 0x05 0x10 0x20 0x30 0x40 0xAC 0xAA Description System is entering S1 sleep state System is entering S2 sleep state System is entering S3 sleep state System is entering S4 sleep state System is entering S5 sleep state System is waking up from the S1 sleep state System is waking up from the S2 sleep state System is waking up from the S3 sleep state System is waking up from the S4 sleep state System has transitioned into ACPI mode. Interrupt controller is in PIC mode. System has transitioned into ACPI mode. Interrupt controller is in APIC mode. ASUS Z9PE-D8 WS 2-25 2.8 1. Jumpers Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. Turn OFF the computer and unplug the power cord. 2. Move the jumper cap from pins 1–2 (default) to pins 2–3. Keep the cap on pins 2–3 for about 5–10 seconds, then move the cap back to pins 1–2. 3. Plug the power cord and turn ON the computer. 4. Hold down the <Del> key during the boot process and enter BIOS setup to re-enter data. Except when clearing the RTC RAM, never remove the cap on CLRTC jumper default position. Removing the cap will cause system boot failure! If the steps above do not help, remove the onboard battery and move the jumper again to clear the CMOS RTC RAM data. After the CMOS clearance, reinstall the battery. 2-26 Chapter 2: Hardware information 2. VGA controller setting (DIAG_VIEW1) This jumper allows you to enable o disable the onboard VGA controller. Set to pins 1-2 to activate the VGA feature. 3��������������������������������������� . SMBUS connection setting (TESLA_M_SW) This jumper allows you to select the connection to BMC or PCH for PCIE 1/3/5/7 SMBUS. ASUS Z9PE-D8 WS 2-27 4. LSI MegaRAID or Intel RSTe selection jumper (3-pin RAID_SEL1) This jumper allows you to select the PCH SATA RAID mode to use LSI MegaRAID software or Intel® Rapid Storage Technology enterprise 3.0 RAID. Place the jumper caps over pins 1–2 if you want to use the LSI MegaRAID software RAID Utility (default); otherwise, place the jumper caps to pins 2–3 to use the Intel® Rapid Storage Technology Enterprise Option ROM Utility. 5����������������������������������������������������� . ME firmware force recovery setting (3-pin ME_RCVR1) This jumper allows you to force Intel Management Engine (ME) boot from recovery mode when ME become corrupted. 2-28 Chapter 2: Hardware information 2.9 Connectors 2.9.1 Rear panel connectors ASUS Z9PE-D8 WS 2-29 1. 2. 3. 4. 5. PS/2 mouse and keyboard port. This port is for a PS/2 mouse and keyboard. LAN 2 (RJ-45) port. This port allows Gigabit connection to a Local Area Network (LAN) through a network hub. Refer to the table below for the LAN port LED indications. LAN 1 (RJ-45) port. This port allows Gigabit connection to a Local Area Network (LAN) through a network hub. Refer to the table below for the LAN port LED indications. USB 2.0 ports 5 and 6. These two 4-pin Universal Serial Bus (USB) ports are available for connecting USB 2.0 devices. Optical S/PDIF Out port. 6. USB 2.0 ports 3 and 4. 7. USB 2.0 ports 1 and 2. 9. Audio I/O ports. 8. USB 3.0 ports 1 and 2. These Universal Serial Bus (USB) ports are available for connecting USB 3.0 devices. LAN port LED indications Activity/Link LED Speed LED OFF OFF Status Description Green Linked Blinking 2-30 No link Data activity ACT/LINK SPEED LED LED Status Description Orange 100 Mbps connection Green 10 Mbps connection 1 Gbps connection LAN port Chapter 2: Hardware information 2.9.2 1. 2. Internal connectors Hard disk activity LED connector (4-pin HDLED1) This LED connector is for the storage add-on card cable connected to the SATA or SAS add-on card. The read or write activities of any device connected to the SATA or SAS add-on card causes the front panel LED to light up. USB connectors (10-1 pin USB78, USB910; A-Type USB12/11) These connectors are for USB 2.0 ports. Connect the USB module cables to connectors USB78 and USB910, then install the modules to a slot opening at the back of the system chassis. These USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed. ASUS Z9PE-D8 WS 2-31 3. 4. USB connectors (USB3_34) This connector is for USB 3.0 ports. Connect the USB module cable to connector USB3_34. CPU, front and rear fan connectors (4-pin CPU_FAN1-2, FRNT_FAN1–4, REAR_FAN1-2) The fan connectors support cooling fans. Connect the fan cables to the fan connectors on the motherboard, ensuring that the black wire of each cable matches the ground pin of the connector. 2-32 • DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components. • These are not jumpers! DO NOT place jumper caps on the fan connectors! • All fans feature the ASUS Fan Speed Control technology. Chapter 2: Hardware information 5. 6. Power supply SMBus Connector (PSUSMB1) This connector supplies power for low-speed system management communications. Serial port connectors (10-1 pin COM1/COM2) These connectors are for the serial (COM) ports. Connect the serial port module cable to one of these connectors, then install the module to a slot opening at the back of the system chassis. ASUS Z9PE-D8 WS 2-33 7. Serial ATA 6.0/3.0 Gb/s connectors (7-pin SATA6G_1-2 [blue]; 7-pin SATA3G_3-6 [black]) These connectors connect to Serial ATA 6.0Gb/s or 3.0 Gb/s hard disk drives and optical disc drives via Serial ATA 6.0Gb/s or 3.0 Gb/s signal cables. 2-34 Chapter 2: Hardware information 8. Marvell® Serial ATA 6.0 Gb/s connectors (7-pin SATA6G_E1/E2/E3/E4 [gray]) These connectors connect to Serial ATA 6.0 Gb/s hard disk drives via Serial ATA 6.0 Gb/s signal cables. • • For high performance of ASUS SSD Caching, please connect one HDD and one SSD to Marvell® SATA6G_E1/E2/E3/E4 connectors. For SSD Caching setup, you can use more than one SSD and only one HDD. • You cannot use ASUS SSD Caching and Marvell® RAID at the same time. • For regular usage, the SATA6G_E1/E2/E3/E4 connectors are recommended for data drivers. • You must install Windows® XP Service Pack 3 or later versions before using Serial ATA hard disk drives. • Press <Ctrl> + <M> during POST to enter the Marvell® RAID utility to create or delete a RAID configuration. • If you want to install a Windows operating system to a RAID configuration created using the Marvell® SATA controller, you have to create a RAID driver disk using the motherboard support DVD and load the driver during OS installation. For 32/64bit Windows XP OS, load first the Marvell ® shared library driver, and then load Marvell® 92xx SATA Controller Driver. For Windows Vista / Windows 7 OS, load only the Marvell® 92xx SATA Controller Driver. ASUS Z9PE-D8 WS 2-35 9. Serial ATA SCU connectors (7-pin SATA_SCU1-4 [black]) These connectors connect to Serial ATA 3.0 Gb/s hard disk drives and optical disc drives via Serial ATA 3.0 Gb/s signal cables. 10. EATX power connectors (24-pin EATXPWR1, 8-pin EATX12V1/EATX12V2) These connectors are for an EATX power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. 2-36 • DO NOT forget to connect the 24+8+8-pin power plugs; otherwise, the system will not boot up. • Use of a PSU with a higher power output is recommended when configuring a system with more power-consuming devices. The system may become unstable or may not boot up if the power is inadequate. • This motherboard supports EATX2.0 PSU or later version. • Ensure that your power supply unit (PSU) can provide at least the minimum power required by your system. Chapter 2: Hardware information 11. System panel connector (20-1 pin PANEL1) This connector supports several chassis-mounted functions. 1) System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. 2)������������������������ Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED. The message LED is controlled by Hardware monitor to indicate an abnormal event occurance. 3) System warning speaker (4-pin SPEAKER) This 4-pin connector is for the chassis-mounted system warning speaker. The speaker allows you to hear system beeps and warnings. 4) Hard disk drive activity LED (2-pin HDDLED) This 2-pin connector is for the HDD Activity LED. Connect the HDD Activity LED cable to this connector. The HDD LED lights up or flashes when data is read from or written to the HDD. 5) Power button/soft-off button (2-pin PWRSW) This connector is for the system power button. Pressing the power button turns the system on or puts the system in sleep or soft-off mode depending on the BIOS settings. Pressing the power switch for more than four seconds while the system is ON turns the system OFF. 6) Reset button (2-pin RESET) This 2-pin connector is for the chassis-mounted reset button for system reboot without turning off the system power. ASUS Z9PE-D8 WS 2-37 12. Auxiliary panel connector (20-2 pin AUX_PANEL1) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. (1) Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable. (2) LAN activity LED (2-pin LAN12_LED) These leads are for Gigabit LAN activity LEDs on the front panel. (3) Chassis intrusion (4-1 pin CHASSIS) These leads are for the intrusion detection feature for chassis with intrusion sensor or microswitch. When you remove any chassis component, the sensor triggers and sends a high-level signal to these leads to record a chassis intrusion event. The default setting is short CASEOPEN and GND pin by jumper cap to disable the function. (4) Locator LED (2-pin LOCATORLED1 and 2-pin LOCATORLED2) These leads are for the locator LED1 and LED2 on the front panel. Connect the Locator LED cables to these 2-pin connector. The LEDs will light up when the Locator button is pressed. (5) Locator Button/Swich (2-pin LOCATORBTN) These leads are for the locator button on the front panel. This button queries the state of the system locator. 2-38 Chapter 2: Hardware information 13. Digital audio connector �������������������� (4-1 pin SPDIF_OUT) This connector is for an additional Sony/Philips Digital Interface (S/PDIF) port(s). Connect the S/PDIF Out module cable to this connector, then install the module to a slot opening at the back of the system chassis. The S/PDIF module is purchased separately. 14. IEEE 1394a port connectors (10-1 pin IE1394_1/2) These connectors are for IEEE 1394a port. Connect the IEEE 1394a module cable to this connector, then install the module to a slot opening at the back of the system chassis. Never connect a USB cable to the IEEE 1394a connector. Doing so will damage the motherboard! The IEEE 1394a module is purchased separately. ASUS Z9PE-D8 WS 2-39 15. VGA connector (VGA_HDR1) This connector supports the VGA High Dynamic-Range interface. 16. Front panel audio connector (10-1 pin AAFP) This connector is for a chassis-mounted front panel audio I/O module that supports either HD Audio or legacy AC`97 audio standard. Connect one end of the front panel audio I/O module cable to this connector. 2-40 • We recommend that you connect a high-definition front panel audio module to this connector to avail of the motherboard’s high-definition audio capability. • If you want to connect a high-definition front panel audio module to this connector, set the Front Panel Type item in the BIOS setup to [HD]; if you want to connect an AC'97 front panel audio module to this connector, set the item to [AC97]. By default, this connector is set to [HD]. Chapter 2: Hardware information 17. ASMB6 header (ASMB6) This connector supports the ASUS Server Management Board 6 series. ASUS Z9PE-D8 WS 2-41 2-42 Chapter 2: Hardware information This chapter describes the power up sequence, and ways of shutting down the system. Chapter 3: 3 Powering up Chapter summary 3.1 3.2 3 Starting up for the first time......................................................... 3-3 Powering off the computer........................................................... 3-4 ASUS Z9PE-D8 WS 3.1 Starting up for the first time 1. After making all the connections, replace the system case cover. 2. Ensure that all switches are off. 3. Connect the power cord to the power connector at the back of the system chassis. 4. Connect the power to a power outlet that is equipped with a surge protector. 5. Turn on the devices in the following order: b. External storage devices (starting with the last device on the chain) 6. 7. a. Monitor c. System power After applying power, the system power LED on the system front panel case lights up. For systems with ATX power supplies, the system LED lights up when you press the ATX power button. If your monitor complies with “green” standards or if it has a “power standby” feature, the monitor LED may light up or switch between orange and green after the system LED turns on. The system then runs the power-on self-test or POST. While the tests are running, the BIOS beeps or additional messages appear on the screen. If you do not see anything within 30 seconds from the time you turned on the power, the system may have failed a power-on test. Check the jumper settings and connections or call your retailer for assistance. At power on, hold down the <Del> key to enter the BIOS Setup. Follow the instructions in Chapter 4. ASUS Z9PE-D8 WS 3-3 3.2 Powering off the computer 3.2.1 Using the OS shut down function If you are using Windows® 2008 Server: 1. Click the Start button, move the cursor to the triangle on the right of Log off, and then click Shut Down. 2. From the Shutdown Event Tracker, select the option that best describes why you want to shut down the computer. 3. Tick Planned. 4. If necessary, key in comments. 5. Click OK. 3.2.2 Using the dual function power switch While the system is ON, press the power switch for less than four seconds to put the system to sleep mode or to soft-off mode, depending on the BIOS setting. 3-4 Chapter 3: Powering up This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided. Chapter 4: 4 BIOS setup Chapter summary 4 4.1 Managing and updating your BIOS............................................. 4-3 4.3 Main menu................................................................................... 4-10 4.2 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 BIOS setup program..................................................................... 4-7 Ai Tweaker menu......................................................................... 4-11 Advanced menu.......................................................................... 4-15 Server Management menu......................................................... 4-41 Event Logs menu........................................................................ 4-44 Boot menu................................................................................... 4-47 Monitor menu.............................................................................. 4-50 Security menu............................................................................. 4-52 Tool menu.................................................................................... 4-53 Exit menu..................................................................................... 4-54 ASUS Z9PE-D8 WS 4.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. 2. 3. ASUS CrashFree BIOS 3 : Allows you to recover the BIOS using a bootable USB flash disk drive when the BIOS file fails or gets corrupted. ASUS EZ Flash 2 : Allows you to update the BIOS using a USB flash disk. BUPDATER utility : Allows you to update the BIOS in DOS mode using a bootable USB flash disk drive. Save a copy of the original motherboard BIOS file to a bootable USB flash disk drive in case you need to restore the BIOS in the future. Copy the original motherboard BIOS using the BUPDATER utility. 4.1.1 ASUS CrashFree BIOS 3 The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process. You can update a corrupted BIOS file using a USB flash drive that contains the updated BIOS file. Prepare a USB flash drive containing the updated motherboard BIOS before using this utility. Recovering the BIOS from a USB flash drive To recover the BIOS from a USB flash drive: 1. 2. Insert the USB flash drive containing the original or new BIOS file to the USB port. The utility will automatically recover the BIOS. It resets the system when the BIOS recovery is finished. DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause system boot failure! The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the ASUS website at www.asus.com to download the latest BIOS file. ASUS Z9PE-D8 WS 4-3 4.1.2 ASUS EZ Flash 2 ASUS EZ Flash 2 feature allows you to update the BIOS without using a DOS‑based utility. Before you start using this utility, download the latest BIOS from the ASUS website at www.asus.com. To update the BIOS using EZ Flash 2: 1. 2. Insert the USB flash disk that contains the latest BIOS file to the USB port. Enter the BIOS setup program. Go to the Tool menu to select ASUS EZ Flash 2 Utility and press <Enter> to enable it. Exit ASUSTek EZ Flash 2 Utility V01.04 Flash Info MODEL: Z9PE-D8 WS VER: 0208 DATE: 10/19/2011 File Path:\ Drive Info fs0:\ Folder Info 12/09/10 10:23p 4194304 Z9PE-D8 WS.ROM File Info MODEL: VER: DATE: Help Info [Enter] Select or Load 3. 4. 5. 6. 4-4 [Tab] Switch [Up/Down/PageUp/PageDown/Home/End] Move [Esc] Exit [F2] Backup Press <Tab> to switch to the Drive Info field. Press the Up/Down arrow keys to find the USB flash disk that contains the latest BIOS, and then press <Enter>. Press <Tab> to switch to the Folder Info field. Press the Up/Down arrow keys to find the BIOS file, and then press <Enter> to perform the BIOS update process. Reboot the system when the update process is done. Chapter 4: BIOS setup • This function can support devices such as a USB flash disk with FAT 32/16 format and single partition only. • DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! Ensure to load the BIOS default settings to ensure system compatibility and stability. Press <F5> and select Yes to load the BIOS default settings. 4.1.3 BUPDATER The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown. The BUPDATER utility allows you to update the BIOS file in DOS environment using a bootable USB flash disk drive with the updated BIOS file. Updating the BIOS file To update the BIOS file using BUPDATER : 1. 2. 3. Visit the ASUS website at www.asus.com and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable USB flash disk drive. Copy the BUPDATER utility (BUPDATER.exe) from the ASUS support website at support.asus.com to the bootable USB flash disk drive you created earlier. Boot the system in DOS mode, then at the prompt, type: BUPDATER /i[filename].ROM where [filename] is the latest or the original BIOS file on the bootable USB flash disk drive, then press <Enter>. A:\>BUPDATER /i[file name].ROM ASUS Z9PE-D8 WS 4-5 The utility verifies the file, then starts updating the BIOS file. ASUSTek BIOS Update for DOS V1.06 (09/08/04) FLASH TYPE: MXIC 25L1605A Current ROM BOARD: Z9PE-D8 WS VER: 0203 DATE: 08/24/2011 Update ROM BOARD: Z9PE-D8 WS VER: 0206 DATE: 09/30/2011 PATH: WARNING! Do not turn off power during flash BIOS Note Writing BIOS: DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure! 5. The utility returns to the DOS prompt after the BIOS update process is completed. Reboot the system from the hard disk drive. The BIOS update is finished! Please restart your system. C:\> 4-6 Chapter 4: BIOS setup 4.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 4.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future. For example, you can enable the security password feature or change the power management settings. This requires you to reconfigure your system using the BIOS Setup program so that the computer can recognize these changes and record them in the CMOS RAM of the firmware chip. The firmware chip on the motherboard stores the Setup utility. When you start up the computer, the system provides you with the opportunity to run this program. Press <Del> during the Power-On Self-Test (POST) to enter the Setup utility; otherwise, POST continues with its test routines. If you wish to enter Setup after POST, restart the system by pressing <Ctrl+Alt+Delete>, or by pressing the reset button on the system chassis. You can also restart by turning the system off and then back on. Do this last option only if the first two failed. The Setup program is designed to make it as easy to use as possible. Being a menu-driven program, it lets you scroll through the various sub-menus and make your selections from the available options using the navigation keys. • The default BIOS settings for this motherboard apply for most conditions to ensure optimum performance. If the system becomes unstable after changing any BIOS settings, load the default settings to ensure system compatibility and stability. Press <F5> and select Yes to load the BIOS default settings. • The BIOS setup screens shown in this section are for reference purposes only, and may not exactly match what you see on your screen. • Visit the ASUS website (www.asus.com) to download the latest BIOS file for this motherboard. ASUS Z9PE-D8 WS 4-7 4.2.1 BIOS menu screen Menu items Main Menu bar Configuration fields General help Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.4.1 UEFI 2.1; PI 0.9 0208 x64 12/14/2011 System Date System Time [Wed 10/19/2011] [15:07:28] Access Level Administrator Memory Information Total Memory 1024 MB (DDR3) Processor CPU Speed Count: 2000 MHz 2 Exit Set the Date, Use Tab to switch between Data elements. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Navigation keys 4.2.2 Menu bar The menu bar on top of the screen has the following main items: Main Ai Tweaker Advanced For changing the basic system configuration For changing the Ai Tweaker settings For changing the advanced system settings Server Mgmt For changing the server management settings Boot For changing the system boot configuration Event Logs For changing the event log settings MonitorFor displaying the system temperature, power status, and changing the fan settings Security For changing the security settings Exit For selecting the exit options Tool For configuring options for special functions To select an item on the menu bar, press the right or left arrow key on the keyboard until the desired item is highlighted. 4-8 Chapter 4: BIOS setup 4.2.3 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Event Logs, Advanced, Monitor, Boot, Tool, and Exit) on the menu bar have their respective menu items. 4.2.4 Submenu items A solid triangle before each item on any menu screen means that the item has a submenu. To display the submenu, select the item and press <Enter>. 4.2.5 Navigation keys At the bottom right corner of a menu screen are the navigation keys for the BIOS setup program. Use the navigation keys to select items in the menu and change the settings. 4.2.6 General help At the top right corner of the menu screen is a brief description of the selected item. 4.2.7 Configuration fields These fields show the values for the menu items. If an item is user-configurable, you can change the value of the field opposite the item. You cannot select an item that is not user-configurable. A configurable field is enclosed in brackets, and is highlighted when selected. To change the value of a field, select it and press <Enter> to display a list of options. 4.2.8 Pop-up window Select a menu item and press <Enter> to display a pop-up window with the configuration options for that item. 4.2.9 Scroll bar A scroll bar appears on the right side of a menu screen when there are items that do not fit on the screen. Press the Up/Down arrow keys or <Page Up> /<Page Down> keys to display the other items on the screen. ASUS Z9PE-D8 WS 4-9 4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears. The Main menu provides you an overview of the basic system information, and allows you to set the system date, time, language, and security settings. The Server Management tab and menu appear only when you install ASMB card on the motherboard. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit BIOS Information BIOS Vendor Core Version Compliancy BIOS Version Build Date American Megatrends 4.6.4.1 UEFI 2.1; PI 0.9 0208 x64 12/14/2011 System Date System Time [Wed 10/19/2011] [15:07:28] Access Level Administrator Memory Information Total Memory 1024 MB (DDR3) Processor CPU Speed Count: 2000 MHz 2 Set the Date, Use Tab to switch between Data elements. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. 4.3.1 System Date [Day xx/xx/xxxx] 4.3.2 System Time [xx:xx:xx] Allows you to set the system date. Allows you to set the system time. 4-10 Chapter 4: BIOS setup 4.4 Ai Tweaker menu The Ai Tweaker menu items allow you to configure overclocking-related items. Be cautious when changing the settings of the Ai Tweaker menu items. Incorrect field values can cause the system to malfunction. The configuration options for this section vary depending on the CPU and DIMM model you installed on the motherboard. Main Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Target CPU Turbo-Mode Speed : 2500MHz Ai Overclock Tuner [Auto] CPU Ratio [Auto] DRAM Timing Control CPU1 Voltage [Auto] VCORE_CPU1 +0.930 V CPU1 VSA Voltage [Auto] VSA_CPU1 +0.896 V CPU2 Voltage [Auto] VCORE_CPU2 +0.928 V CPU2 VSA Voltage [Auto] VSA_CPU2 +0.884 V DRAM Voltage (CHA, CHB) [Auto] +VDDQ_AB_CPU1 +1.474 V DRAM Voltage (CHC, CHD) [Auto] +VDDQ_CD_CPU1 +1.476 V DRAM Voltage (CHE, CHF) [Auto] +VDDQ_EF_CPU2 +1.474 V DRAM Voltage (CHG, CHH) [Auto] +VDDQ_GH_CPU2 +1.476 V Clock Spread Spectrum [Disabled] Min=0.800V Max=1.520V Standard=By CPU Increment=0.005V =/-:Raise/Reduce →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Ai Overclock Tuner [Auto] Allows you to select the CPU overclocking options to achieve the desired CPU internal frequency. Select any of these preset overclocking configuration options: [Auto] [Manual] Loads the optimal settings for the system. Allows you to individually set overclocking parameters. BCLK Frequency [XXX] Allows you to adjust the CPU and VGA frequency to enhance the system performance. Set Ai Overclock Tuner to [Manual] to show BCLK Frequency. Use the <+> and <-> keys to adjust the value. You can also key in the desired value using the numeric keypad. The values range from 80.0MHz to 300.0MHz. ASUS Z9PE-D8 WS 4-11 CPU Ratio [Auto] This item allows users adjust the maximum non-turbo CPU ratio. Use the <+> and <-> keys to adjust the value. The ����������������������������������������������� values range from 12 to 57 with 1 interval. CPU1 Voltage [Auto] Use the <+> and <-> keys to adjust the value. The �������������������������������� values range from 0.800V to 1.520V with 0.005V interval. CPU1 VSA Voltage [Auto] Use the <+> and <-> keys to adjust the value. The �������������������������������� values range from 0.800V to 1.520V with 0.005V interval. CPU2 Voltage [Auto] Use the <+> and <-> keys to adjust the value. The �������������������������������� values range from 0.800V to 1.520V with 0.005V interval. CPU2 VSA Voltage [Auto] Use the <+> and <-> keys to adjust the value. The �������������������������������� values range from 0.800V to 1.520V with 0.005V interval. DRAM Voltage (CHA, CHB) [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������� values range from 1.20V to 1.52V with 0.005V interval. DRAM Voltage (CHC, CHD) [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������� values range from 1.20V to 1.52V with 0.005V interval. DRAM Voltage (CHE, CHF) [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������� values range from 1.20V to 1.52V with 0.005V interval. DRAM Voltage (CHG, CHH) [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������� values range from 1.20V to 1.52V with 0.005V interval. Clock Spread Spectrum [Disabled] [Disabled]Enhances BCLK overclocking ability. [Enabled] For [EMI] control. 4-12 Chapter 4: BIOS setup 4.4.1 DRAM Timing Control Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Ai Tweaker Primary Timings DRAM CAS# Latency DRAM CAS# Latency 9 DRAM RAS# to CAS# Delay DRAM RAS# to CAS# Delay 9 DRAM RAS# PRE Time DRAM RAS# PRE Time 9 DRAM RAS# ACT Time DRAM RAS# ACT Time 24 DRAM COMMAND Mode DRAM COMMAND Mode 1 Secondary Timings DRAM RAS# to RAS# Delay DRAM RAS# to RAS# Delay 4 DRAM REF Cycle Time DRAM REF Cycle Time 74 DRAM WRITE Recovery Time DRAM WRITE Recovery Time 10 DRAM READ to PRE Time DRAM READ to PRE Time 5 DRAM FOUR ACT WIN Time DRAM FOUR ACT WIN Time 20 DRAM WRITE to READ Delay DRAM WRITE to READ Delay 5 DRAM Write Latency DRAM Write Latency 7 [Auto] [Auto] [Auto] Min=0.800V Max=1.520V Standard=By CPU Increment=0.005V =/-:Raise/Reduce [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] [Auto] →←: S e l e c t S c r e e n ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit [Auto] [Auto] Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Use the scroll to view items. Primary Timings DRAM CAS# Latency [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 3 to 15 with 1 interval. DRAM RAS# to CAS# Delay [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 4 to 15 with 1 interval. DRAM RAS# PRE Time [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 4 to 15 with 1 interval. ASUS Z9PE-D8 WS 4-13 DRAM RAS# ACT Time [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 4 to 40 with 1 interval. DRAM COMMAND Mode [Auto] Use the <+> and <-> keys to adjust the value. The ����������������������������� values range from 1 to 3 with 1 interval. Secondary Timings DRAM RAS# to RAS# Delay [Auto] Use the <+> and <-> keys to adjust the value. The ����������������������������� values range from 4 to 7 with 1 interval. DRAM REF Cycle Time [Auto] Use the <+> and <-> keys to adjust the value. The ���������������������������� values range from 48 to 511 with 1 interval. DRAM WRITE Recovery Time [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 5 to 31 with 1 interval. DRAM READ to PRE Time [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 4 to 15 with 1 interval. DRAM FOUR ACT WIN Time [Auto] Use the <+> and <-> keys to adjust the value. The ���������������������������� values range from 16 to 63 with 1 interval. DRAM WRITE to READ Delay [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 4 to 15 with 1 interval. DRAM WRITE Latency [Auto] Use the <+> and <-> keys to adjust the value. The ������������������������������ values range from 1 to 15 with 1 interval. 4-14 Chapter 4: BIOS setup 4.5 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Main Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit CPU Configuration Parameters CPU Configuration CPU Power Management Configuration Chipset Configuration PCH SATA Configuration PCH SCU SAS Configuration PCI Subsystem Setting USB Configuration ACPI Settings WHEA Configuration APM Serial Port Console Redirection Onboard LAN Configuration ME Subsystem Marvell SATA Configuration Legacy Devices Configuration Runtime Error Logging →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. 4.5.1 CPU Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced CPU Confguration Socket specific CPU Information Socket 1 CPU Information Socket 2 CPU Information CPU Speed 2000 MHz 64-bit Supported Hyper Threading Active Processor Cores Limit CPUID Maximum Execute Disable Bit Server Class Hardware Prefetcher Adjacent Cache Line Prefetch DCU Streamer Prefetcher DCU IP Pretetcher Intel Virtualization Technology Local APIC Mode [Enabled] [All] [Disabled] [Enabled] [Custom] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Auto] →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. ASUS Z9PE-D8 WS 4-15 Socket 1 CPU Information Enter to view socket specific CPU Information. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Socket 1 CPU Information Intel(R) Xeon(R) CPU E5-2660 0 @ 2.20GHz CPU Signature Microcode Patch Max CPU Speed Min CPU Speed Processor Cores Intel HT Technology Intel VT-X Technology 206d6 613 2200 MHz 1200 MHz 6 Supported Supported L1 L1 L2 L3 32kB x8 32kB x8 256kB x8 20480 kB Data Cache Code Cache Cache Cache →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Socket 2 CPU Information Enter to view socket specific CPU Information. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Socket 2 CPU Information Intel(R) Xeon(R) CPU E5-2660 0 @ 2.20GHz CPU Signature Microcode Patch Max CPU Speed Min CPU Speed Processor Cores Intel HT Technology Intel VT-X Technology 206d6 613 2200 MHz 1200 MHz 8 Supported Supported L1 L1 L2 L3 32 kB x 8 32 kB x 8 256 kB x 8 20480 kB Data Cache Code Cache Cache Cache →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. 4-16 Chapter 4: BIOS setup Hyper Threading [Enabled] This item allows you to enable/disable the Intel Hyper-Threading Technology function. Enable for Windows XP and Linux or disable for other OS. When disabled, only one thread per activated core is enabled. Configuration options: [Disabled] [Enabled] Active Processor Cores [All] This item sets the number of cores to enable in each processor package. Configuration options: [All] [1] [2] [3] [4] [5] [6] [7] Limit CPUID Maximum [Disabled] Setting this item to [Enabled] allows legacy operating system to boot even without support for CPUs with extended CPUID functions. Configuration options: [Disabled] [Enabled] Execute Disable Bit [Enabled] XP can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS (Windows Server 2003 SP1, Windows XP SP2, SuSE Linux 9.2, Redhat Enterprise 3 Update 3). Configuration options: [Disabled] [Enabled] Server Class [Custom] Use Intel recommended prefetch settings. Configuration options: [Enterprise] [High Performance(HPC)] [Custom] You can only customize the items below when you enable the Server Class to [Custom]. Hardware Prefetcher [Enabled] This item allows you to turn on/off the mid level cache(L2) streamer prefetcher.Configuration options: [Disabled] [Enabled] Adjacent Cache Line Prefetch [Enabled] This item allows you to turn on/off prefetching of adjacent cache lines. Configuration options: [Disabled] [Enabled] DCU Streamer Prefetcher [Enabled] This item allows you to enable/disable prefetching of next L1 data line based upon multiple loads in same cache line. Configuration options: [Disabled] [Enabled] DCU IP Prefetcher [Enabled] This item allows you to enable/disable prefetching of next L1 line based upon sequential load history. Configuration options: [Disabled] [Enabled] ASUS Z9PE-D8 WS 4-17 Intel Virtualization Technology [Enabled] When this item is enabled, VMM can utilize the additional hardware capabilities provided by Vanderpool Technology. Configuration options: [Disabled] [Enabled] Local APIC Mode [Auto] Allows you to enable one or both the Advanced Programmable Interrupt Controllers (APIC) with APIC ID values greater than 254. Configuration options: [Auto] [xAPIC] []x2APIC] 4.5.2 CPU Power Management Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced CPU Power Management Confguration Power Technology [Custom] Enhanced Intel SpeedStep Technolog [Enabled] Turbo Mode [Enabled] P-STATE Coordination [HW_ALL] CPU C3 Report [Disabled] CPU C6 Report [Enabled] CPU C7 Report [Disabled] Package C State limit [C6] Energy Performance [Balanced Performance] Factory long duration power limit 95 Watts Long Duration Power Limit 0 Factory long duration maintained 1000 ms Long Duration Maintained 0 Recommended short duration power1 1.2 * Long Duration Short Duration Power Limit 0 Enable the power management features →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Power Technology [Custom] This item allows you to enable power management features. Configuration options: [Disable] [Energy Efficient] [Custom] You can only customize the items below when you enable the Power Technology to [Custom]. Enhanced Intel SpeedStep Technology [Enabled] Enable Intel SpeedStep for allowing the system operation system to dynamically adjust processor voltage and cores frequency to result in decreased average power consumption and decreased average heat production. Configuration options: [Disabled] [Enabled] 4-18 Chapter 4: BIOS setup Turbo Mode [Enabled] This item automatically allows processor cores to run faster than the base operating frequency if it’s operating below power, current, and temperature specification limit. Configuration options: [Disabled] [Enabled] P-STATE Coordination [HW_ALL] This item allows you to change P-STATE Coordination type. Configuration options: [HW_ALL] [SW_ALL] [SW_ANY] CPU C3 Report [Disabled] This item allows you to enable/disable CPU C3(ACPI C2) report. Configuration options: [Disabled] [Enabled] CPU C6 Report [Enabled] This item allows you to enable/disable CPU C6(ACPI C3) report. Configuration options: [Disabled] [Enabled] CPU C7 Report [Disabled] This item allows you to enable/disable CPU C7(ACPI C3) report. Configuration options: [Disabled] [Enabled] Package C State limit [C6] This item allows you to set package C State limit. Configuration options: [C0] [C2] [C6] [C7] [No Limit] Energy Performance [Balanced Performance] This item allows you to optimize between performance and power savings. Configuration options: [Performance] [Balanced Performance] [Balanced Energy] [Energy Efficient] Factory long duration power limit Long Duration Power Limit 95Watts 0 Factory long duration maintained Long Duration Maintained 1000 ms 0 Allows you to set long duration power limit in watts. Use the <+> and <-> keys to adjust the value. Allows you to set time window which the long duration power is maintained. Use the <+> and <-> keys to adjust the value. Recommended short duration power1 1.2 * Long Duration Short Duration Power Limit 0 Allows you to set short duration power limit in watts. Use the <+> and <-> keys to adjust the value. ASUS Z9PE-D8 WS 4-19 4.5.3 Chipset Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced QPI Configuration Memory Configuration CPU II0 Bridge Configuration PCH Configuration Intel(R) VT for Directed I/O Configuration QPI Configuration Page QPI Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Current QPI Link Speed Current QPI Link Freq Isoc QPI Link Speed Mode QPI Link Frequency Select QPI Link0s QPI Link0p QPI Link1 Fast 7.2 GT/s [Enabled] [Fast] [Auto] [Disabled] [Disabled] [Enabled] Enable/Disable Isoc Isoc [Enabled] Configuration options: [Disabled] [Enabled] QPI Link Speed Mode [Fast] This item allows you to select the QPI link speed as either the fast mode or slow mode. Configuration options: [Slow] [Fast] QPI Link Frequency Select [Auto] This item allows for selecting the QPI link frequency Configuration options: [Auto] [6.4 GT/s] [7.2 GT/s (Fast Mode Only)] [8.0 GT/s (Fast Mode Only)] QPI Link0s [Disabled] Configuration options: [Disabled] [Enabled] QPI Link0p [Disabled] Configuration options: [Disabled] [Enabled] QPI Link1 [Enabled] Configuration options: [Disabled] [Enabled] 4-20 Chapter 4: BIOS setup Memory Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Compatibility RID Memory Configuration [Enabled] Total Memory Current Memory Mode Currently Memory Speed Mirroring Sparing Memory Mode Numa DDR Speed Channel Interleaving Rank Interleaving Patrol Scrub Demand Scrub Data Scrambling Device Tagging Thermal Throttling Enable High Temp. Allow 2x Refresh Altitude Memory HOT sensor support DIMM Information 16384 MB (DDR3) Independent 1333 MHz Not Possible Not Possible [Independent] [Enabled] [Auto] [Auto] [Auto] [Disabled] [Enabled] [Enabled] [Disabled] [CLTT] [Disabled] [Enabled] [300 M] [Enabled] Support for Compatibility Revision ID(CRID) Functionality mentioned in Sandybridge bios spec →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Compatibility RID [Enabled] Supports compatibility revision ID (CRID) functionality mentioned in Sandybridge BIOS spec. Configuration options: [Enabled] [Disabled] Memory Mode [Independent] Select the mode for memory initializaton. Configuration options: [Independent] Numa [Enalbled] Allows you to disable or enable Non Uniform Memory Access. Configuration options: [Enabled] [Disabled] DDR Speed [Auto] This item allows you to configure force DDR speed. Configuration options: [Auto] [Force DDR3 800] [Force DDR3 1066] [Force DDR3 1333] [Force DDR3 1600] [Force DDR3 1866] [Force DDR3 2133] [Force DDR3 2400] [Force DDR3 2666] Channel Interleaving [Auto] Select different channel interleaving setting. Configuration options: [Auto] [1 Way] [2 Way] [3 Way] [4 Way] ASUS Z9PE-D8 WS 4-21 Rank Interleaving [Auto] Select different rank interleaving setting. Configuration options: [Auto] [1 Way] [2 Way] [4 Way] [8 Way] Patrol Scrub [Disabled] This item allows you to enable/disable Patrol Scrub. Configuration options: [Disabled] [Enabled] Demand Scrub [Enabled] This item allows you to enable/disable Demand Scrubbing Feature. Configuration options: [Enabled] [Disabled] Data Scrambling [Enabled] This item allows you to enable/disable Data Scrambling. Configuration options: [Enabled] [Disabled] Device Tagging [Disabled] This item allows you to enable/disable Device Tagging. Configuration options: [Enabled] [Disabled] Thermal Throttling [CLTT] Configuration options: [Disabled] [OLTT] [CLTT] Enable High Temp. [Disabled] This item allows you to enable/disable high temperature mode. Configuration options: [Disabled] [Enabled] Allow 2x Refresh [Enabled] This item allows you to enable/disable refreshing function. Configuration options: [Disabled] [Enabled] Altitude [300 M] Shows system altitude above the sea level in meters. Configuration options: [Auto] [300 M] [900 M] [1500 M] [3000 M] Memory Hot sensor support [Enabled] Configuration options: [Disabled] [Enabled] 4-22 Chapter 4: BIOS setup DIMM Information Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced CPU1 DIMM Information DIMM_A1 Present 8192 MB(Indep DIMM_B1 Not Present DIMM_C1 Not Present DIMM_D1 Not Present CPU2 DIMM Information DIMM_E1 Not Present DIMM_F1 Not Present DIMM_G1 Present 8192 MB Inde[ DIMM_H1 Not Present CPU IIO Bridge Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel(R) I/OAT DCA Support VGA Priority TargetVGA [Disabled] [Enabled] [Offboard] VGA From CPU Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Intel(R) I/OAT [Disabled] This item allows you to enable/disable Intel I/O accelaration technology. Configuration options: [Disabled] [Enabled] DCA Support [Enabled] This item allows you to enable/disable direct cache access support. Configuration options: [Disabled] [Enabled] ASUS Z9PE-D8 WS 4-23 VGA Priority [offboard] This item allows you to decide the priority between onboard and 1st offboard video device found. Configuration options: [Onboard] [Offboard] PCH Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Name Stepping SB Chipset Configuration PCH Compatibility RID Support for PCH Compatibility Patsburg 06 (C1 Stepping) Revision ID(CRID) Functionality. [Disabled] Deep Sx SCU devices Onboard SATA RAID Oprom [Disabled] [Enabled] [Enabled] Audio Configuration Azalia HD Audio [Enabled] High Precision Event Timer Configuration High Precision Timer [Enabled] →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. PCH Compatibility RID [Disabled] This item allows support for PCH compatibility. Configuration options: [Disabled] [Enabled] Deep Sx [Disabled] Configuration options: [Disabled] [Enabled in S5 (Battery)] [Enabled in S5] [Enabled in S4 and S5 (Battery)] [Enabled in S4 and S5] Mobile platforms support deep S4/S5 in DC only and desktop platforms support deep S4/S5 in AC only. SCU devices [Enabled] This item allows you to enable/disable Patsburg SCU devices. Configuration options: [Enabled] [Disabled] Onboard SATA RAID Oprom [Enabled] This item allows you to enable/disable onboard SATA RAID option rom if Launch Storage Oprom is enabled. Configuration options: [Disabled] [Enabled] 4-24 Chapter 4: BIOS setup Audio Configuration Azalia HD Audio [Enabled] This item allows you to enable/disable Azalia HD Audio. Configuration options: [Disabled] [Enabled] High Precision Event Timer Configuration High Precision Timer [Enabled] This item allows you to enable/disable High Precision Event Timer. Configuration options: [Disabled] [Enabled] Intel(R) VT for Directed I/O Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Intel(R) VT-d [Enabled] Enables or Disables BIOS ACPI Auto Configuration. Intel(R) VT-d [Disabled] This item allows you to enable or disable Intel VT-d. Configuration options: [Enabled] [Disabled] The following item appears only when you set Intel(R) VT-d to [Enabled]. Coherency Support [Disabled] This item allows you to enable/disable VT-d Engine Coherency support. Configuration options: [Disabled] [Enabled] ATS Support [Disabled] This item allows you to enable/disable VT-d Engine address translation services (ATS) support. Configuration options: [Disabled] [Enabled] ASUS Z9PE-D8 WS 4-25 4.5.4 PCH SATA Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced SATA SATA SATA SATA SATA SATA Port1 Port2 Port3 Port4 Port5 Port6 ST3500320AS(500GB) Not Present Not Present Not Present ASUS DRW ATAPI Not Present SATA Mode S.M.A.R.T. Status Check (1)IDE Mode. (2)AHCI Mode. (3)RAID Mode. [AHCI Mode] [Enabled] Aggressive Link Power Management[Enabled] Port1 Port2 Port3 Port4 Port5 Port6 Staggered Staggered Staggered Staggered Staggered Staggered Spin-up Spin-up Spin-up Spin-up Spin-up Spin-up [Disabled] [Disabled] [Disabled] [Disabled] [Disabled] [Disabled] →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. SATA Mode [AHCI Mode] This item allows you to set the SATA configuration. Configuration options: [Disabled] [IDE Mode] [AHCI Mode] [RAID Mode] • If you want to use the Serial ATA hard disk drives as Parallel ATA physical storage devices, set this item to [IDE Mode]. • If you want the Serial ATA hard disk drives to use the Advanced Host Controller Interface (AHCI), keep the default setting [AHCI Mode]. The AHCI allows the onboard storage driver to enable advanced Serial ATA features that increases storage performance on random workloads by allowing the drive to internally optimize the order of commands. • If you want to create RAID sets with LSI MegaRAID utility, or Intel® Rapid Storage Technology Enterprise from the Serial ATA hard disk drives, set this item to [RAID Mode]. AHCI Mode Allows you to enable the Aggressive Link Power Management and support Staggered Spin-up. S.M.A.R.T. Status Check [Enabled] S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) is a monitor system. When hard disk read/write errors occur, this feature allows the hard disk to report warning messages during the POST. Configuration options: [Enabled] [Disabled] 4-26 Chapter 4: BIOS setup Aggressive Link Power Management [Enabled] Configuration options: [Enabled] [Disabled] Port 1-6 Staggered Spin-up [Disabled] Configuration options: [Enabled] [Disabled] IDE Mode Allows you to to enable or disable the SATA controllers. Serial-ATA Controller 0 [Enhanced] This item appears only when you set the SATA Mode item to [IDE Mode]. Set to [Enhanced] to support two SATA 6.0 Gb/s and two SATA 3.0 Gb/s devices. Set to [Compatible] when using Windows 98/NT/2000/MS-DOS. Up to four SATA devices are supported under these operating systems. Configuration options: [Disabled] [Enhanced] [Compatible] Serial-ATA Controller 1 [Enhanced] This item appears only when you set the SATA Mode item to [IDE Mode]. Set to [Enhanced] to support two SATA 3.0 Gb/s devices. Configuration options: [Disabled] [Enhanced] S.M.A.R.T. Status Check [Enabled] S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) is a monitor system. When read/write of your hard disk errors occur, this feature allows the hard disk to report warning messages during the POST. Configuration options: [Enabled] [Disabled] 4.5.5 PCH SCU Configuration This menu automatically detects and displays Device 1-4. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Device1 Device2 Device3 Device4 Not Not Not Not Present Present Present Present →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. ASUS Z9PE-D8 WS 4-27 4.5.6 PCI Subsystem Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced PCI Bus Driver Version PCI Option ROM Handling PCI ROM Priority V 2.05.00 [EFI Compatible ROM] In case of multiple Option ROMs (Legacy and EFI Compatible), specifies what PCI option ROM to lanuch. PCI Common Settings PCI Latency Timer VGA Palette Snoop PERR# Generation SERR# Generation Load RT32 Image [32 PCI Bus Clocks] [Disabled] [Disabled] [Disabled] [Enabled] PCI Express Settings PCIE Slot Option Rom Configuration →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. PCI ROM Priority [EFI Compatible ROM] This item specifies which PCI option ROM to launch between multiple option ROMs (Legacy and EFI Compatible). Configuration options: [Legacy ROM] [EFI Compatible ROM] PCI Latency Timer [32 PCI Bus Clocks] This item configures the value to be programmed into PCI Latency Timer Register. Configuration options: [32 PCI Bus Clocks] [64 PCI Bus Clocks] [96 PCI Bus Clocks] [128 PCI Bus Clocks] [160 PCI Bus Clocks] [192 PCI Bus Clocks] [224 PCI Bus Clocks] [248 PCI Bus Clocks] VGA Palette Snoop [Disabled] This item enables or disables VGA pallette register snooping. Configuration options: [Disabled] [Enabled] PERR# Generation [Disabled] This item enables or disables PCI device to generate PERR#. Configuration options: [Disabled] [Enabled] SERR# Generation [Disabled] This item enables or disables PCI device to generate SERR#. Configuration options: [Disabled] [Enabled] 4-28 Chapter 4: BIOS setup PCI Express Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced PCI Express Link Register Settings ASPM Support [Disabled] WARNING: Enabling ASPM may cause some PCI-E device to fail Enables or Disables PCI Express Device Relaxed Ordering. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. ASPM Support [Disabled] This item allows you to set the ASPM level. Configuration options: [Disabled] [Auto] [Force L0s] [Force L0s] [Auto] [Disabled] ASUS Z9PE-D8 WS Force all links to L0s state. BIOS auto configure. Disabled ASPM. 4-29 PCIE Slot Option ROM Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Legacy OpROM Support Launch Storage OpROM [Enabled] PCIE1 PCIE2 PCIE3 PCIE4 PCIE5 PCIE6 PCIE7 [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] Option Option Option Option Option Option Option Rom Rom Rom Rom Rom Rom Rom Enable or Disable Boot Option for Legacy Mass Storage Devices with Option ROM. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Launch Storage OpROM [Enabled] This item allows you to enable or disable boot option for Legacy Mass Storage devices with Option ROM. Configuration options: [Disabled] [Enabled] PCIE1 Option Rom [Enabled] Configuration options: [Disabled] [Enabled] PCIE2 Option Rom [Enabled] Configuration options: [Disabled] [Enabled] PCIE3 Option Rom [Enabled] Configuration options: [Disabled] [Enabled] PCIE4 Option Rom [Enabled] Configuration options: [Disabled] [Enabled] PCIE5 Option Rom [Enabled] Configuration options: [Disabled] [Enabled] PCIE6 Option Rom [Enabled] Configuration options: [Disabled] [Enabled] PCIE7 Option Rom [Enabled] Configuration options: [Disabled] [Enabled] 4-30 Chapter 4: BIOS setup 4.5.7 USB Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced USB Configuration USB Devices: 2 Hubs Legacy USB Support USB3.0 Support XHCI Hand-off EHCI Hand-off [Enabled] [Enabled] [Enabled] [Disabled] USB Hardware Delays and Time-outs USB transfer time-out Device reset time-out Device power-up delay [20 sec] [20 sec] [Auto] USB Ports Configuration Enabled Legacy USB support. AUTO option disables legacy support if no USB devices are connected. DISABLE option will keep USB devices available only for EFI applications. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Legacy USB Support [Enabled] This item enables or disables Legacy USB device support. Configuration options: [Enabled] [Disabled] [Auto] USB3.0 Support [Enabled] This item enables or disables USB3.0 (XHCI) Controller support. Configuration options: [Disabled] [Enabled] XHCI Hand-off [Enabled] This is a workaround for OSes without XHCI ownership change should be claimed by XHCI driver. Configuration options: [Disabled] [Enabled] EHCI Hand-off [Disabled] This is a workaround for OSes without EHCI ownership change should be claimed by EHCI driver. Configuration options: [Disabled] [Enabled] USB Hardware Delays and Time-outs USB transfer time-out [20 sec] This item sets the time-out value for control, bulk, and interrupt transfer. Configuration options: [1 sec] [5 sec] [10 sec] [20 sec] Device reset time-out [20 sec] USB mass storage device Start Unit command time-out. Configuration options: [10 sec] [20 sec] [30 sec] [40 sec] ASUS Z9PE-D8 WS 4-31 Device power-up delay [Auto] This item sets the maximum time the device will take before it properly reports itself to the Host Controller. ‘Auto’ uses default values: for a Root port, it is 100ms; for a Hub port, the delay is taken from Hub descriptor. Configuration options: [Manual] [Auto] Device power-up delay in seconds [X] This item appears only when you set the Device power-up delay item to [Manual]. Use the <+> and <-> keys to adjust the value. The values range from 1 to 40 with a one-second interval. USB Ports Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced EHCI Controller 1 EHCI Controller 2 [Enabled] [Enabled] USB USB USB USB USB USB USB USB USB USB USB USB USB USB [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] [Enabled] Port Port Port Port Port Port Port Port Port Port Port Port Port Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Enable/Disable USB 2.0 (EHCI) Support. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. EHCI Controller 1/2 [Enabled] This item allows you to enable or disable USB 2.0 (EHCI) Support. If we disable the EHCI Controller in BIOS > South Bridge > USB configuration, the USB device will all disable in OS. Configuration options: [Disabled] [Enabled] USB Port 1/14 [Enabled] These items allow you to enable or disable USB ports 1 to 14. Configuration options: [Disabled] [Enabled] 4-32 Chapter 4: BIOS setup 4.5.8 ACPI Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced ACPI Settings Enable ACPI Auto Configuration [Disabled] Enables or Disables BIOS ACPI Auto Configuration. Enable Hibernation [Enabled] ACPI Sleep State [S3 (Suspend to RAM)] Lock Legacy Resources [Disabled] Enable ACPI Auto Configuration [Disabled] Allows you to enable or disable BIOS ACPI Auto Configuration. Configuration options: [Disabled] [Enabled] The following item appears only when you set Enabled ACPI Auto Configuration to [Disabled]. Enable Hibernation [Enabled] Enables or disables system ability to Hibernate (0S/S4 sleep state). This option may be not effective with some OS. Configuration options: [Disabled] [Enabled] ACPI Sleep State [S3 (Suspend to RAM)] Allows you to set the ACPI Sleep State. Configuration options: [Suspend Disabled] [S1 (CPU Stop Clock)] [S3 (Suspend to RAM)] Lock Legacy Resources [Disabled] Allows to enable or disable Lock Legacy Resources. Configuration options: [Disabled] [Enabled] 4.5.9 WHEA Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced WHEA Support [Enabled] Enable or disable Windows Hardware Error Architecture. WHEA Support [Enabled] Allows you to enable or disable the Windows Hardware Error Architecture support. Configuration options: [Disabled] [Enabled] ASUS Z9PE-D8 WS 4-33 4.5.10 APM setting Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Restrore Power On Power On Power On Power On Power On AC By By By By By Power Loss PS/2 Keyboard PS/2 Mouse PCIE Ring RTC [Last State] [Disabled] [Disabled] [Disabled] [Disabled] [Disabled] Specify what state to go to when power is re-applied after a power failure (G3 state). Restore AC Power Loss [Last State] When set to [Power Off], the system goes into off state after an AC power loss. When set to [Power On], the system will reboot after an AC power loss. When set to [Last State], the system goes into either off or on state, whatever the system state was before the AC power loss. Configuration options: [Power Off] [Power On] [Last State] Power On By PS/2 Keyboard [Disabled] [Disabled]Disables the PS/2 Keyboard from generating a wake event. [Enabled]Enables the PS/2 Keyboard to generate a wake event. Power On By PS/2 Mouse [Disabled] [Disabled]Disables the PS/2 Mouse from generating a wake event. [Enabled]Enables the PS/2 Mouse to generate a wake event. Power On By PCIE [Disabled] [Disabled]Disables the PCIE devices from generating a wake event. [Enabled]Enables the PCIE devices to generate a wake event. Power On By Ring [Disabled] [Disabled]Disables the Ring devices from generating a wake event. [Enabled]Enables the Ring devices to generate a wake event. Power On By RTC [Disabled] [Disabled]Disables RTC from generating a wake event. [Enabled]When set to [Enabled], the items RTC Alarm Date (Days) and Hour/Minute/Second will become user-configurable with set values. 4-34 Chapter 4: BIOS setup 4.5.11 Serial Port Console Redirection Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced COM1 Console Redirection Console Redirection Settings [Disabled] COM2 Console Redirection Console Redirection Settings [Enabled] Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Console Redirection Settings Console Redirection Enable or Disable. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. COM1 Console Redirection [Disabled] This item enables or disables the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Console Redirection to [Enabled]. Console Redirection Settings This item becomes configurable only when you enable the Console Redirection item. The settings specify how the host computer and the remote computer (which the user is using) will exchange data. Both computers should have the same or compatible settings. Terminal Type [VT-UTF8] Allows you to set the terminal type. [VT100] ASCII char set [VT100+] Extends VT100 to support color, function keys, etc. [VT-UTF8]Uses UTF8 encoding to map Unicode chars onto 1 or more bytes [ANSI] Extended ASCII char set Bits per second [57600] Selects serial port transmission speed. The speed must be matched on the other side. Long or noisy lines may require lower speeds. Configuration options: [9600] [19200] [38400] [57600] [115200] ASUS Z9PE-D8 WS 4-35 Data Bits [8] Configuration options: [7] [8] Parity [None] A parity bit can be sent with the data bits to detect some transmission errors. [Mark] and [Space] parity do not allow for error detection. [None] No parity bit [Even] Parity bit is 0 if the num of 1’s in the data bits is even [Odd] Parity bit is 0 if num of 1’s in the data bits is odd [Mark] Parity bit is always 1 [Space] Parity bit is always 0 Stop Bits [1] Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.) The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit. Configuration options: [1] [2] Flow Control [VT100] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port. Configuration options: [VT100] [Hardware RTS/CTS] [Software Xon/Xoff] Recorder Mode [Disabled] With this mode enabled, only text will be sent. This is to capture Terminal data. Configuration options: [Disabled] [Enabled] Recorder 100x31 [Disabled] This item allows you to enable or disable extended terminal resolution. Configuration options: [Disabled] [Enabled] Legacy OS Redirction Resolution [80x24] This item configures the number of rows and columns supported on legacy OS. Configuration options: [80x24] [80x25] COM2 Console Redirection [Disabled] Enables or disables the console redirection feature. Configuration options: [Disabled] [Enabled] Console Redirection Settings Please refer to the description of the Console Redirection Settings item under COM1 for details. 4-36 Chapter 4: BIOS setup Serial Port for Out-of-Band Management/ Windows Emergency Management Services (EMS) Console Redirection [Disabled] Enables or disables the console redirection feature. Configuration options: [Disabled] [Enabled] The following item appears only when you set Console Redirection to [Enabled]. Console Redirection Settings Out-of-Band Mgmt Port [COM1] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port. Configuration options: [COM1] [COM2] Terminal Type [VT-UTF8] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port. Configuration options: [VT100] [VT100+] [VT-UTF8] [ANSI] Bits per second [115200] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port. Configuration options: [9600] [19200] [57600] [115200] Flow Control [VT100] Microsoft Windows Emergency Management Services (EMS) allow for remote management of a Windows Server OS through a serial port. Configuration options: [VT100] [Hardware RTS/CTS] [Software Xon/Xoff] 4.5.12 Onboard LAN Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Onboard LAN Configuration INTEL W82574L OpROM1 INTEL W82574L OpROM2 [PXE] [PXE] Launch INTEL W82574L OpROM INTEL W82574L OpROM1 [PXE] This item launched INTEL W82574L OpROM1. Configuration options: [Disabled] [PXE] [iSCSI] INTEL W82574L OpROM2 [PXE] This item launched INTEL W82574L OpROM2. Configuration options: [Disabled] [PXE] [iSCSI] ASUS Z9PE-D8 WS 4-37 4.5.13 Marvell SATA Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Marvell SATA Configuration Marvell Storage Controller Marvell Storage OPROM [Enabled] [Enabled] Marvell Storage Controller [Enabled] Configuration options: [Disabled] [Enabled] Marvell Storage OPROM [Enabled] Configuration options: [Disabled] [Enabled] 4-38 Chapter 4: BIOS setup 4.5.14 Onboard Devices Configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Serial Port 1 Configuration Serial Port 2 Configuration VIA 1394 Controller [Enabled] Asmedia USB 3.0 Controller [Enabled] Asmedia USB 3.0 Battery Charging S [Enabled] Set Parameters of serial Port 1(COM1). Serial Port1/2 Configuration This item allows you to set parameters of serial ports 1 and 2. Serial Port [Enabled] This item allows you to enable or disable the Serial Port. Configuration options: [Disabled] [Enabled] Device Mode [Standard Serial Port Mode] This item allows you to change the serial port mode. Configuration options: [Standard Serial Port Mode] VIA 1394 Controller [Enabled] This item allows you to enable or disable VIA 1394. Configuration options: [Disabled] [Enabled] Asmedia USB 3.0 Controller [Enabled] This item allows you to enable or disable Asmedia USB 3.0. Configuration options: [Disabled] [Enabled] Asmedia USB 3.0 Battery Charging S [Enabled] This item allows you to enable or disable Asmedia USB 3.0 Battery Charging S. Configuration options: [Disabled] [Enabled] ASUS Z9PE-D8 WS 4-39 4.5.15 Runtime Error Logging Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Advanced Runtime Error Logging Support [Disabled] Runtime Error Logging Support [Disabled] This item allows you to enable or disable Runtime Error Logging Support. Configuration options: [Disabled] [Enabled] The following item appears only when you set Runtime Error Logging Support to [Enabled]. PCI Error Logging Support [Disabled] This item allows you to enable or disable PCI Error Logging. Configuration options: [Disabled] [Enabled]. 4-40 Chapter 4: BIOS setup 4.6 Server Management menu The Server Management menu displays the server management status, and allows you to change the settings. The Server Management menu appears only when you install ASMB card on the motherboard. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Main Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool BMC Firmware Version: O/S Watchdog Timer O/S Wtd Timer Timeout O/S Wtd Timer Policy [Disabled] [10 minutes] [Reset] System Event Log BMC network configuration Exit If enabled, starts a BIOS timer which can only be shut off by Intel Management Software after the OS loads. Helps determine that the OS successfully loaded or follows the O/S Boot Watchdog Timer policy. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. O/S Watchdog Timer [Disabled] If enabled, starts a BIOS timer which can only be shut off by Intel Management Software after the OS loads. Helps determine that the OS sucessfully loaded or follows the O/S Boot Watchdog TImer Policy. Configuration options: [Enabled] [Disabled] O/S Wtd Timer Timeout [10 minutes] Allows to configure the length of the O/S Boot Watchdog Timer. Not available if O/S Boot Watchdog Timer is disabled. Configuration options: [5 minutes] [10 minutes] [15 minutes] [20 minutes] O/S Wtd Timer Policy [Reset] Allows to configure how the system should respond if the OS Boot Watchdog Timer expires. Not available if O/S Boot Watchdog Timer is disabled. Configuration options: [Do Nothing] [Reset] [Power Down] ASUS Z9PE-D8 WS 4-41 4.6.1 System Event Log Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt Enabling/Disabling Options SEL Components [Disabled] Erasing Settings Erase SEL When SEL is Full [No] [Do Nothing] Note: All values changed here do not take effect until computer is restarted. Change this to enable or disable all features of system Event Logging during boot. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. SEL Components [Disabled] Allows you to enable or disable all features of system Event Logging during boot. Configuration options: [Disabled] [Enabled] • The following items appears only when you set SEL Components to [Enabled]. • All values changed here do not take effect until computer is restarted. Erase SEL [No] Allows to choose options for erasing SEL. Configuration options: [No] [Yes, On next reset] [Yes, On every reset] When SEL is Full [Do Nothing] Allows to choose options for reactions to a full SEL. Configuration options: [Do Nothing] [Erase Immediately] 4-42 Chapter 4: BIOS setup 4.6.2 BMC network configuration Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Server Mgmt BMC network configuration Lan1 Lan1 Lan1 Lan1 Lan1 Lan1 IP Address in BMC: Subnet Mask in BMC: Gateway Address in BMC: MAC Address in BMC: Address Source in BMC: Configuration Address source 000.000.000.000 000.000.000.000 000.000.000.000 00.00.00.00.00.00 DHCP Mode Select to configure LAN channel parameters statically or dynamically(by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase [Previous State] →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Configuration Address source [Previous State] Select to configure LAN channel parameters statically or dynamically(by BIOS or BMC). Unspecified option will not modify any BMC network parameters during BIOS phase. Configuration options: [Previous State] [Static Mode] [DHCP Mode] The following items appears only when you set Configuration Address source to [Static Mode]. Station IP address [0.0.0.0] Allows to input Station IP address. Subnet mask [0.0.0.0] Allows to input Subnet mask. Gateway IP address [0.0.0.0] Allows to input Gateway IP address. ASUS Z9PE-D8 WS 4-43 4.7 Event Logs menu The Event Logs allows you to change or view the event log settings. The Event Logs menu appears when the ASMB card is not installed on the motherboard. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Event Logs Change Smbios Event Log Settings View System Event Log View System Event Log Press <Enter> to change the Smbios Log configuration. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. All values changed here do not take effect until computer is restarted. Change Smbios Event Log Settings Press <Enter> to change the Smbios Event Log configuration. For more information on this configuration, refer to 4.7.1 Change Smbios Event Log Settings. View Smbios Event Log Press <Enter> to view all smbios event logs. View System Event Log Press <Enter> to view all system event logs. 4-44 Chapter 4: BIOS setup 4.7.1 Change Smbios Event Log Settings Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Event Logs Enabling/Disabling Options Smbios Event Log [Enabled] Erasing Settings Erase Event Log When Log is Full [No] [Do Nothing] Smbios Event Log Standard Settings Log System Boot Event [Disabled] MECI 1 METW 60 Custom Option Log OEM Codes [Enabled] Convert OEM Codes [Disabled] Note: All values changed here do not take effect until computer is restarted. Change this to enable or disable all features of Smbios Event Logging during boot. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. All values changed here do not take effect until computer is restarted. Enabling/Disabling Options Smbios Event Log [Enabled] Change this to enable or disable all features of Smbios Event Logging during boot. Configuration options: [Disabled] [Enabled] Erasing Settings Erase Event Log [No] Choose options for erasing Smbios Event Log. Erasing is done prior to any logging activation during reset. Configuration options: [No] [Yes, Next reset] [Yes, Every reset] When Log is Full [Do Nothing] This item allows you to choose options for reactions to a full Smbios Event Log. Configuration options: [Do Nothing] [Erase Immediately] Smbios Event Log Standard Settings Log System Boot Event [Disabled] This item allows you to choose options to enable/disable logging of System boot event. Configuration options: [Enabled] [Disabled] ASUS Z9PE-D8 WS 4-45 MECI [1] This item allows you to set Mutiple Event Count Increment (MECI). The number of occurrences of a duplicate event that must pass before the multiplt-event counter associated with the log entry is updated, specified as a numeric value in the range 1 to 255. METW [60] This item allows you to set Mutiple Event Time Windows (METW). The number of minutes which must pass between duplicate log entries which utilize a multipleevent counter. The value ranges from 0 to 99 minutes. Custom Options Log OEM Codes [Enabled] This item allows you to enable or disable the logging of EFI Status Codes as OEM Codes (if not already converted to legacy). Configuration options: [Disabled] [Enabled] Convert OEM Codes [Disabled] This item allows you to enable or disable the converting of EFI Status Codes to Standard Smbios Types (Not all may be translated). Configuration options: [Disabled] [Enabled] 4-46 Chapter 4: BIOS setup 4.8 Boot menu The Boot menu items allow you to change the system boot options. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Main Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Boot Configuration Setup Prompt Timeout Bootup NumLock State 1 [On] Full Screen Logo [Enabled] CSM16 Module Version 07.67 GateA20 Active Option ROM Messages Interrupt 19 Capture Boot Device Seeking UEFI Boot [Upon Request] [Force BIOS] [Enabled] [Endless PXE] [Disabled] Boot Option Priorities Boot Option #1 Boot Option #2 [AMI Virtual CDROMO...] [IBA GE Slot 0600 v...] CD/DVD ROM Drive BBS Priorities Hard Drive BBS Priorities Network Device BBS Priorities Exit Number of seconds to wait for setup activation key. 65535(0xFFFF) means indefinite waiting. →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Setup Prompt Timeout [xx] Use the <+> and <-> keys to adjust the number of seconds to wait for setup activation key. Bootup NumLock State [On] This item allows you to select the power-on state for the NumLock. Configuration options: [Off] [On] Full Screen Logo [Enabled] This item allows you to enable or disable the full screen logo display feature. Configuration options: [Disabled] [Enabled] 1. Set Full Screen Logo to [Enabled] to use the ASUS MyLogo2™ feature. 2. Set Full Screen Logo to [Disabled] to select the desired Post Report waiting time from 1~10 sec. Post Report [5 sec] Allows you to select a desired post report waiting time. This item only appears when you set the Full Screen Logo to [Disabled]. Configuration options: [1 sec] - [10 sec] [Until Press ESC ASUS Z9PE-D8 WS 4-47 CSM16 Module Version GateA20 Active [Upon Request] [Upon Request] GA20 can be disabled using BIOS services. [Always] D o not allow disable GA20; this optionis useful when any RT code is executed above 1MB. Option ROM Messages [Force BIOS] Allows you to set the display mode for Options ROM. Configuration options: [Force BIOS] [Keep Current] Interrupt 19 Capture [Enabled] Allows Option ROMs to trap interrupt 19. Configuration options: [Disabled] [Enabled] Boot Device Seeking [Endless PXE] [Endless PXE] Continuous seek remote boot image until boot image found or user abort (press Ctrl+Alt+Del). [Normal] Seek remote boot image once then stop. UEFI Boot [Disabled] Enables or disables UEFI Boot. Configuration options: [Disabled] [Enabled] Boot Option Priorities These items specify the boot device priority sequence from the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system. • To select the boot device during system startup, press <F8> when ASUS Logo appears. • To access Windows OS in Safe Mode, please press <F8> after POST. Boot Option #1/#2/#3/#4 [IBA GE Slot 0600 v...] Configuration options: [SATA P2: ASUS ...] [SATA P3: WDC WD80...] [AMI Virtual CDROM...] [IBA GE Slot 0600 v...] These items appear only when you connect SATA ODD or hard drive to the SATA ports. CD/DVD ROM Drive BBS Priorities Hard Drive BBS Priorities Network Device BBS Priorities These settings allow you to set the booting order of the SATA devices. 4-48 Chapter 4: BIOS setup Setup Mode [EZ Mode] [Advanced Mode] Sets Advanced Mode as the default screen for entering the BIOS setup program. [EZ Mode] Sets EZ Mode as the default screen for entering the BIOS setup program. Boot Option Priorities These items specify the boot device priority sequence from the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system. Select [Disabled] to disallow this function. • • To select the boot device during system startup, press <F8> when ASUS Logo appears. To access Windows OS in Safe Mode, press <F8> after POST. Boot Override These items displays the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system. Click an item to start booting from the selected device. ASUS Z9PE-D8 WS 4-49 4.9 Monitor menu The Monitor menu displays the system temperature/power status, and allows you to change the fan settings. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Main Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit CPU1 Temperature CPU2 Temperature TR1 Temperature TR2 Temperature CPU FAN1 Speed CPU FAN2 Speed FRNT FAN1 Speed FRNT FAN2 Speed FRNT FAN3 Speed FRNT FAN4 Speed REAR FAN1 Speed REAR FAN2 Speed +VTT_CPU VCORE_CPU1 VCORE_CPU2 VSA_CPU1 VSA_CPU2 +VDDQ_AB_CPU1 +VDDQ_CD_CPU1 +VDDQ_EF_CPU2 +VDDQ_GH_CPU2 +5VSB +5V +12V +3.3V 90.0ºC/194.0ºF 90.0ºC/194.0ºF 18.0ºC/64.4ºF 6.0ºC/42.8ºF 3658 RPM 3678 RPM N/A N/A N/A N/A N/A N/A +1.026 V +0.996 V +0.996 V +0.898 V +0.912 V +1.510 V +1.526 V +1.474 V +1.474 V +4.921 V +4.966 V +11.592 V +3.264 V VBAT +3.3VSB +3.168 V +3.234 V FAN Speed Control →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit [Generic Mode] Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Use the scroll to view items. CPU 1/2; TR1 1/2 Temperature ������������� [xxxºC/xxxºF] The onboard hardware monitor automatically detects and displays the CPU and motherboard component temperatures. Select Ignore if you do not wish to display the detected temperatures. CPU FAN1/2 Speed; FRNT FAN1–4 Speed; REAR FAN1/2 Speed [xxxx RPM] or [Ignore] / [N/A] The onboard hardware monitor automatically detects and displays the speed of CPU fans, front fans, and rear fan in rotations per minute (RPM). If the fan is not connected to the motherboard, the field shows N/A. 4-50 Chapter 4: BIOS setup +VTT_CPU Voltage, VCORE1/2 Voltage, VSA_CPU1/2 +VDDQ_AB_ CPU1 Voltage, +VDDQ_CD_CPU1 Voltage, +VDDQ_EF_CPU2 Voltage, +VDDQ_GH_CPU2 Voltage, +5VSB Voltage, +5V Voltage, +12V Voltage, +3.3V Voltage, VBAT Voltage, +3.3VSB Voltage The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators. FAN Speed Control [Generic Mode] This item allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for more efficient system operation. Configuration options: [Generic Mode] [High Speed Mode] [Full Speed Mode] ASUS Z9PE-D8 WS 4-51 4.10 Security menu The Security menu items allow you to change the system security settings. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Main Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Password Description If ONLY the Administrator's password is set, then this only limits access to Setup and is only asked for when entering Setup If ONLY the User's password is set, then this is a power on password and must be entered to boot or enter Setup. In Setup the User will have Administrator rights The password length must br in the following range: Minimum length 3 Maximum length 20 Set Setup Administrator Password Administrator Password User Password If you have forgotten your BIOS password, erase the CMOS Real Time Clock (RTC) RAM to clear the BIOS password. See section 2.6 Jumpers for information on how to erase the RTC RAM. Administrator Password If you have set an administrator password, we recommend that you enter the administrator password for accessing the system. Otherwise, you might be able to see or change only selected fields in the BIOS setup program. To set an administrator password: 1. 2. 3. Select the Administrator Password item and press <Enter>. From the Create New Password box, key in a password, then press <Enter>. Confirm the password when prompted. To change an administrator password: 1. 2. 3. 4. Select the Administrator Password item and press <Enter>. From the Enter Current Password box, key in the current password, then press <Enter>. From the Create New Password box, key in a new password, then press <Enter>. Confirm the password when prompted. To clear the administrator password, follow the same steps as in changing an administrator password, but press <Enter> when prompted to create/confirm the password. 4-52 Chapter 4: BIOS setup User Password If you have set a user password, you must enter the user password for accessing the system. To set a user password: 1. 2. 3. Select the User Password item and press <Enter>. From the Create New Password box, key in a password, then press <Enter>. Confirm the password when prompted. To change a user password: 1. 2. 3. 4. Select the User Password item and press <Enter>. From the Enter Current Password box, key in the current password, then press <Enter>. From the Create New Password box, key in a new password, then press <Enter>. Confirm the password when prompted. To clear the user password, follow the same steps as in changing a user password, but press <Enter> when prompted to create/confirm the password. 4.11 Tool menu The Tool menu items allow you to configure options for special functions. Select an item then press <Enter> to display the submenu. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Main Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit ASUS EZ Flash 2 Utility Be used to update BIOS ASUS EZ Flash 2 Utility This item allows you to run ASUS EZ Flash BIOS ROM Utility when you press <Enter>. Check section 4.1.2 ASUS EZ Flash 2 Utility for details. ASUS Z9PE-D8 WS 4-53 4.12 Exit menu The Exit menu items allow you to save or discard your changes to the BIOS items. Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc. Main Ai Tweaker Advanced Server Mgmt Event Logs Boot Monitor Security Tool Exit Discard Changes & Exit Save Changes & Reset Discard Changes & Reset Exit system setup without saving any changes. Restore Defaults Boot Override IBA GE Slot 0600 v1376 IBA GE Slot 0700 v1376 AMI Virtual CDROM0 1.00 Launch EFI Shell from filesystem device →←: Select Screen ↑↓: Select Item Enter: Select Item +/-: Change Opt. F1: General Help F2: Previous Values F5: Optimized Defaults F10: Save & Exit ESC: Exit Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc. Pressing <Esc> does not immediately exit this menu. Select one of the options from this menu or <F10> from the legend bar to exit. Discard Changes & Exit This option allows you to exit the Setup program without saving your changes. When you select this option or if you press <Esc>, a confirmation window appears. Select Yes to discard changes and exit. Save Changes & Reset Once you are finished making your selections, choose this option from the Exit menu to ensure the values you selected are saved. When you select this option or if you press <F10>, a confirmation window appears. Select Yes to save changes and exit. Discard Changes & Reset This option allows you to reset the Setup program without saving your changes. When you select this option, a confirmation window appears. Select Yes to discard changes and reset. Restore Defaults This option allows you to restore/load defaults values for all the setup options. When you select this option, a confirmation window appears. Select Yes to load optimized defaults. Boot Override These items displays the available devices. The device items that appears on the screen depends on the number of devices installed in the system. Click an item to start booting from the selected device. 4-54 Chapter 4: BIOS setup This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities. 5 RAID configuration Chapter summary 5 5.1 Setting up RAID............................................................................. 5-3 5.3 Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM Utility...................................................................... 5-25 5.5 Marvell RAID utility..................................................................... 5-41 5.2LSI Software RAID Configuration Utility .................................... 5-5 5.4 Intel® Rapid Storage Technology enterprise Utility (Windows).................................................................................... 5-35 ASUS Z9PE-D8 WS 5.1 Setting up RAID The motherboard supports the following SATA RAID solutions: • • • LSI MegaRAID software RAID Configuration Utility with RAID 0, RAID 1, and RAID 10 support (for both Linux and Windows OS). Intel Rapid Storage Technology enterprise SCU / SATA Option ROM Utility with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS only). Marvell RAID Utility with RAID 0, RAID 1, and RAID 10 support. 5.1.1 RAID definitions RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup. RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive. RAID 1E (Enhanced RAID 1) has a striped layout with each stripe unit having a secondary (or alternate) copy stored on a different disk. You can use three or more hard disk drives for this configuration. RAID 10 is data striping and data mirroring combined without parity (redundancy data) having to be calculated and written. With the RAID 10 configuration you get all the benefits of both RAID 0 and RAID 1 configurations. Use four new hard disk drives or use an existing drive and three new drives for this setup. RAID 5 stripes both data and parity information across three or more hard disk drives. Among the advantages of RAID 5 configuration include better HDD performance, fault tolerance, and higher storage capacity. The RAID 5 configuration is best suited for transaction processing, relational database applications, enterprise resource planning, and other business systems. Use a minimum of three identical hard disk drives for this setup. • If you want to boot the system from a hard disk drive included in a created RAID set, copy first the RAID driver from the support DVD to a floppy disk before you install an operating system to the selected hard disk drive. • Please refer to chapter 2 for how to select the RAID configuration utility. Move the jumper to choose between LSI MegaRAID and Intel® Rapid RAID. ASUS Z9PE-D8 WS 5-3 5.1.2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array. To install the SATA hard disks for RAID configuration: 1. 2. 3. Install the SATA hard disks into the drive bays following the instructions in the system user guide. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard. Connect a SATA power cable to the power connector on each drive. 5.1.3 Setting the RAID item in BIOS You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA hard disk drives attached to the SATA connectors supported by Intel® C602 chipset. To do this: 1. Enter the BIOS Setup during POST. 3. Set SATA Mode to [RAID Mode] 2. 4. Go to the Advanced Menu > PCH SATA Configuration, then press <Enter>. Press <F10> to save your changes and exit the BIOS Setup. Refer to Chapter 4 for details on entering and navigating through the BIOS Setup. 5.1.4 RAID configuration utilities Depending on the RAID connectors that you use, you can create a RAID set using the utilities embedded in each RAID controller. For example, use the LSI Logic Embedded SATA RAID Setup Utility or the Intel® Rapid Storage Technology if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the Intel® C602 chipset. Refer to the succeeding section for details on how to use the RAID configuration utility. 5-4 Chapter 5: RAID configuration 5.2LSI Software RAID Configuration Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the LSI MegaRAID software RAID configuration utility: 1. 2. Turn on the system after installing all the SATA hard disk drives. During POST, the LSI MegaRAID software RAID configuration utility automatically detects the installed SATA hard disk drives and displays any existing RAID set(s). Press <Ctrl> + <M> to enter the utility. LSI MegaRAID Software RAID BIOS Version A.10 09231523R LSI SATA RAID Found at PCI Bus No:00 Dev No:1F Device present at Port 0 ST3160812AS 152114MB Device present at Port 1 ST3160812AS 152114MB Device present at Port 2 ST3160812AS 152114MB Device present at Port 3 ST3160812AS 152114MB Press Ctrl-M or Enter to run LSI Software RAID Setup Utility. 3. • The LSI MegaRAID software RAID configuration utility automatically configures to RAID 1 when the SATA to RAID Mode is enabled. • The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference. • When you create RAID sets with the LSI MegaRAID software RAID configuration utility, the boot priority of the SATA optical drive has to be manually adjusted. Otherwise, the system will not boot from the connected SATA ODD. The utility main window appears. Use the arrow keys to select an option from the Management Menu and then press <Enter>. Refer to the Management Menu descriptions on the next page. At the bottom of the screen is the legend box. The keys on the legend box allow you to navigate through the setup menu options or execute commands. The keys on the legend box vary according to the menu level. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Configure VD(s) Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option ASUS Z9PE-D8 WS 5-5 Menu Description Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command. This menu also allows you to view, add, or clear RAID configurations or select the boot drive Initialize Allows you to initialize the virtual drives of a created RAID set Objects Allows you to initialize virtual drives or change the virtual drive parameters Rebuild Allows you to rebuild failed drives Check Consistency Allows you to check the data consistency of the virtual drives of a created RAID set 5.2.1 Creating a RAID set The LSI Software RAID Configuration Utility allows you to create a RAID 0, RAID 1, or RAID 10 set using two types of configurations: Easy and New. In Easy Configuration, the virtual drive parameters are set automatically. In New Configuration, you manually set the virtual drive parameters. Using Easy Configuration To create a RAID set using the Easy Configuration option: 1. From the Management Menu, select Configure > Easy Configuration, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration New Configuration Management Menu View/Add Configuration Configure Clear Configuration Initialize Select Boot Drive Objects Rebuild Check Consistency Defines Physical Arrays. An Array Will Automatically Become A VD Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 5-6 Chapter 5: RAID configuration 2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Use the up/down arrow keys to select the drives you want to include in the RAID set, and then press <Space>. When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Easy Configuration - ARRAY SELECTION MENU Management Menu Configure Initialize Objects Rebuild Check Consistency PORT # 0 ONLIN A00-00 1 ONLIN A00-01 2 READY 3 READY Port # 2 DISK 74.74GB HDS728080PLA380 05.01C05 SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Virtual Drives,F4-HSP 3. 4. • The information of the selected hard disk drive displays at the bottom of the screen. • You need at least two identical hard disk drives when creating a RAID 1 set. • You need at least four identical hard disk drives when creating a RAID 10 set. Select all the drives required for the RAID set, and then press <F10> to configure array setting. Press <Space> to select the configurable array. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Easy Configuration - ARRAY SELECTION MENU Select Configurable Array(s) PORT # A-0 0 DNLIN A00-00 SPAN-1 1 DNLIN A00-01 Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit ASUS Z9PE-D8 WS 5-7 5. Press <F10> again, the virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.580GB PORT 2 # Configure 0 DNLIN A00-00 Initialize Objects 1 DNLIN A00-01 Rebuild Check Consistency Virtual Drive 0 RAID = 1 Units= MB Size = 152146MB DWC = Off RA = On Accept SPAN = NO 64 KB ONLINE Choose RAID Level For This VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 6. 7. Select RAID from the Virtual Drive sub-menu, and then press <Enter>. Select the RAID level from the menu, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.580GB PORT 2 # 64 KB Configure 0 DNLIN A00-00 Initialize Objects 1 DNLIN A00-01 Rebuild Check Consistency Virtual Drive 0 RAID Level RAID = 1 RAID 0 Units= MB RAID 1 Size = 152146MB DWC = Off RA = On Accept SPAN = NO ONLINE Choose RAID Level For This VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 5-8 Chapter 5: RAID configuration 8. 9. Select Units from the Virtual Drive sub-menu, and then press <Enter>. Select the units for virtual drive size from the menu, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.580GB PORT 2 # 64 KB ONLINE Configure 0 DNLIN A00-00 Initialize Objects 1 DNLIN A00-01 Rebuild Select Units For VD Size Check Consistency MB Virtual Drive 0 GB RAID = 1 TB Units= MB Size = 152146MB DWC = Off RA = On Accept SPAN = NO Select Units For VD Size Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 10. When creating a RAID 1 or a RAID 10 set, select DWC from the Virtual Drive menu, and then press <Enter>. When creating a RAID 0 set, proceed to step 12. 11. Select On to enable the Disk Write Cache setting, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOSVirtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.580GB PORT 2 # 64 KB Configure 0 DNLIN A00-00 Initialize Objects 1 DNLIN A00-01Change DWC Rebuild Off Check Consistency On Virtual Drive 0 RAID = 1 Units= MB Size = 152146MB DWC = Off RA = On Accept SPAN = NO ONLINE Disk Write Cache Setting Of VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option Enabling DWC can improve the performance, but with the risk of data loss. ASUS Z9PE-D8 WS 5-9 12. When finished setting the selected virtual drive configuration, select Accept from the menu, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.580GB PORT 2 # Configure 0 DNLIN A00-00 Initialize Objects 1 DNLIN A00-01 Rebuild Check Consistency Virtual Drive 0 RAID = 1 Units= MB Size = 152146MB DWC = Off RA = On Accept SPAN = NO 64 KB ONLINE Accept This VD Configuration And Go To Next VD Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit 13. Follow step 2 to 12 to configure additional virtual drives. 14. Press <Esc> to finish RAID configuration. When prompted to save configuration, select Yes from the menu, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Configuration Menu Save Configuration? Easy Configuration Yes New Management Menu Configuration No View/Add Configuration Configure Clear Configuration Initialize Virtual Drive(s) Configured Boot Drive Objects LD Select RAID Size #Stripes StripSz Status Rebuild Check Consistency 0 1 148.580GB 2 64 KB ONLINE Select Yes Or No Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 5-10 Chapter 5: RAID configuration Using New Configuration When a RAID set already exists, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration. To create a RAID set using the New Configuration option 1. From the Management Menu, select Configure > New Configuration, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration New Configuration Management Menu View/Add Configuration Configure Clear Configuration Initialize Select Boot Drive Objects Rebuild Check Consistency Clear Existing Configuration And Start A New Configuration Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 2. Follow step 2 to 9 of the previous section: Using Easy Configuration. 4. Key-in the desired virtual drive size, and then press <Enter>. 3. Select Size from the Virtual Drive menu, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Virtual VersionDrive(s) A.10.09231523R Configured LD RAID Size #Stripes StripSzMENU Status Easy Configuration - ARRAY SELECTION Management 0 Menu 1 148.580GB PORT 2 # Configure 0 DNLIN A00-00 Initialize Objects 1 DNLIN A00-01 Rebuild Check Consistency Enter VD Size: 152146_ Virtual Drive 0 RAID = 1 Units= MB Size = 152146MB DWC = Off RA = On Accept SPAN = NO 64 KB ONLINE Enter VD Size: Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option 5. Follow step 10 to 14 of the previous section: Using Easy Configuration to create the RAID set. ASUS Z9PE-D8 WS 5-11 5.2.2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, select Configure > View/Add Configuration, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration New Configuration Management Menu View/Add Configuration Configure Clear Configuration Initialize Select Boot Drive Objects Rebuild Check Consistency View/Add to The Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drive(s) you want to include in the RAID set, then press <Space>. When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R View/Add Configuration - ARRAY SELECTION MENU Management Menu Configure Initialize Objects Rebuild Check Consistency Port # 2 DISK PORT # 0 ONLIN A00-00 1 ONLIN A00-01 2 READY 3 READY 77247MB HDS728080PLA380 PF20A60A SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Virtual Drives,F4-HSP The information of the selected hard disk drive displays at the bottom of the screen. 3. 5-12 Follow step 3 to 12 of section 5.2.1 Creating a RAID set: Using Easy Configuration to add a new RAID set. Chapter 5: RAID configuration 5.2.3 Initializing the virtual drives After creating the RAID set(s), you must initialize the virtual drives. You may initialize the virtual drives of a RAID set(s) using the Initialize or Objects command on the Management Menu. Using the Initialize command To initialize the virtual drive using the Initialize command 1. From the Management Menu, select Initialize, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Initialize VD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The screen displays the available RAID set(s) and prompts you to select the virtual drive to initialize. Use the arrow keys to select the virtual drive from the Virtual Drive selection, and then press <Space>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD RAID 0 1 Virtual Drive(s) Configured Size #Stripes StripSz 148.580GB 2 64 KB Status ONLINE Virtual Drives Virtual Drive 0 Select VD SPACE-(De)Select, F10-Initialize ASUS Z9PE-D8 WS 5-13 3. Press <F10> to start initialization. When prompted, select Yes from the Initialize? dialog box, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD RAID 0 1 Virtual Drive(s) Configured Size #Stripes StripSz 148.580GB 2 Status 64 KB ONLINE Initialize? Yes No Virtual Drives Virtual Drive 0 Init Will Destroy Data On Selected VD(s) SPACE-(De)Select, F10-Initialize Initializing a virtual drive erases all data on the drive. 4. A progress bar appears on screen. If desired, press <Esc> to abort initialization. When initialization is completed, press <Esc>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Virtual Drive(s) Configured Management Menu LD RAID Size #Stripes StripSz Configure 0 Init10Of VD 154494MB 4 64 KB Is In Process Initialize Objects VD 0 Initialization Complete. Press Esc.. Rebuild Check Consistency Status ONLINE ¦ 100% Completed Virtual Drives Virtual Drive 0 SPACE-(De)Select, F10-Initialize 5-14 Chapter 5: RAID configuration Using the Objects command To initialize the virtual drives using the Objects command 1. From the Management Menu, select Objects > Virtual Drive, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. Select the virtual drive to initialize from the Virtual Drives sub‑menu, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Select VD Press ENTER To Select A VD, <Del> To Delete A VD ASUS Z9PE-D8 WS 5-15 3. Select Initialize from the pop-up menu, and then press <Enter> to start initialization. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Check Consistency View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4. When prompted, press the <Space> to select Yes from the Initialize? dialog box, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Initialize? Check Consistency Yes View/Update Parameters No Init Will Destroy Data On Selected VD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 5. 5-16 A progress bar appears on screen. If desired, press <Esc> to abort initialization. When initialization is completed, press <Esc>. Chapter 5: RAID configuration 5.2.4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu. To rebuild a failed hard disk drive 1. From the Management Menu, select Rebuild, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The PHYSICAL DRIVES SELECTION MENU displays the available drives connected to the SATA ports. Select the drive you want to rebuild, and then press <Space>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu Configure Initialize Objects Rebuild Check Consistency Port # 1 DISK PORT # 0 ONLIN A00-00 1 FAIL A00-01 77247MB HDS728080PLA380 PF20A60A SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives ASUS Z9PE-D8 WS 5-17 3. After selecting the drive to rebuild, press <F10>. When prompted, press <Y> to rebuild the drive. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # Configure 0 ONLIN A00-00 Initialize Objects 1 RBLD A00-01 Rebuild Check Consistency Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)? Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives 4. 5-18 When rebuild is complete, press any key to continue. Chapter 5: RAID configuration 5.2.5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set. Using the Check Consistency Command To check data consistency using the Check Consistency command 1. From the Management Menu, select Check Consistency, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency CC Of VD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. The screen displays the available RAID set(s) and prompts you to select the virtual drive to check. Press <Space> to select the virtual drive from the Virtual Drive sub-menu, and then press <F10>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD RAID 0 1 Virtual Drive(s) Configured Size #Stripes StripSz 148.580GB 2 64 KB Status ONLINE Virtual Drives Virtual Drive 0 Select VD SPACE-(De)Select, ASUS Z9PE-D8 WS F10-Check Consistency 5-19 3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Management Menu Configure Initialize Objects Rebuild Check Consistency LD 0 Virtual Drive(s) Configured RAID Size #Stripes StripSz 10 154494MB 4 64 KB Yes No Status ONLINE Consistency Check? Virtual Drives Virtual Drive 0 Select VD SPACE-(De)Select, F10-Check Consistency A progress bar appears on screen. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Virtual Drive(s) Configured Management Menu LD RAID Size #Stripes StripSz Configure 0 10 154494MB 64 KB CC Under Process 4 Initialize Objects VD 0 Consistency Check. Press Esc to Abort. Rebuild Check Consistency Status ONLINE ¦ 85 % Completed Virtual Drives Virtual Drive 0 The Data On The Drives Is Inconsistency. Repair Done! SPACE-(De)Select, 4. 5-20 F10-Check Consistency While checking the disk consistency, press <Esc> to display the following options. • Stop - Stops the consistency check. The utility stores the percentage of disk checked, and when you restart checking, it continues from the last percentage completed rather than from zero percent. • Continue- Continues the consistency check. • Abort 5. When checking is complete, press any key to continue. - Aborts the consistency check. When you restart checking, it continues from zero percent. Chapter 5: RAID configuration Using the Objects command To check data consistency using the Objects command 1. 2. 3. 4. 5. From the Management Menu, select Objects, and then select Virtual Drive from the sub-menu. Use the arrow keys to select the virtual drive you want to check, and then press <Enter>. Select Check Consistency from the pop-up menu, and then press <Enter>. When prompted, use the arrow keys to select Yes from the dialog box to check the drive. When checking is complete, press any key to continue. ASUS Z9PE-D8 WS 5-21 5.2.6 Deleting a RAID configuration To delete a RAID configuration 1. From the Management Menu, select Configure > Clear Configuration, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration New Configuration Management Menu View/Add Configuration Configure Clear Configuration Initialize Select Boot Drive Objects Rebuild Check Consistency Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. When prompted, use the arrow keys to select Yes from the Clear Configuration? dialog box, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration New Configuration Management Menu Clear Configuration? View/Add Configuration Configure Yes Clear Configuration Initialize No Drive Select Boot Objects Rebuild Check Consistency Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 3. 5-22 The utility clears all the current array(s). Press any key to continue. Chapter 5: RAID configuration 5.2.7 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. See section 5.2.1 Creating a RAID set: Using New Configuration for details. To select the boot drive from a RAID set 1. From the Management Menu, select Configure > Select Boot Drive, and then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Configuration Menu Easy Configuration New Configuration Management Menu View/Add Configuration Configure Clear Configuration Initialize Select Boot Drive Objects Rebuild Check Consistency Select A Boot VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2. When prompted, use the arrow keys to select the bootable virtual drive from the list, then press <Enter>. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Bootable VDs(1):Current Boot VD(0) Configuration BootMenu Drive 0 Easy Configuration New Configuration Management Menu View/Add Configuration Configure Clear Configuration Initialize Select Boot Drive Objects Rebuild Check Consistency Select A Boot VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 3. The virtual drive is selected as boot drive. Press any key to continue. ASUS Z9PE-D8 WS 5-23 5.2.8 Enabling WriteCache You may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. The WriteCache function is recommended for RAID 1 and RAID 10 sets. To enable WriteCache 1. 2. From the Management Menu, select Objects > Adapter, select an existing adapter, and then press <Enter> to display the adapter properties. Select Disk WC, and then press <Enter> to turn on the option. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Adapter 0 Rebuild Rate = 30 ObjectsChk Const Rate = 30 Management Menu Adapter FGI Rate = 30 Configure Virtual Drive BGI Rate = 30 Initialize Physical DriveDisk WC = Off Objects Read Ahead = On Rebuild Bios State = Enable Check Consistency Cont On Error = Yes Fast Init = Enable Auto Rebuild = On Auto Resume = Enable Disk Coercion = 1GB Factory Default Disk Write Cache - Off(Write Through) or On(Write Back) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 3. 4. From the Management Menu, select Objects > Virtual Drive, select an existing adapter and press <Enter>. Select View/Update Parameters and press <Enter> to display the adapter properties. Select Disk WC, and then press <Enter> to turn on the option. LSI Software RAID Configuration Utility Ver C.05 Sep 17, 2010 BIOS Version A.10.09231523R Virtual Drive RAID = 0 Objects Size = 148.580GB Management Menu Adapter Stripe Size = 64KB Configure Virtual Drive #Stripes = 2 Initialize Physical Drive State = OPTIMAL Objects Spans = 1 Rebuild Disk WC = On Check Consistency Read Ahead = On Disk Write Cache Setting of VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 5. 5-24 When finished, press any key to continue. Chapter 5: RAID configuration 5.3Intel® Rapid Storage Technology enterprise SCU/SATA Option ROM Utility The Intel® Rapid Storage Technology enterprise SCU / SATA Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. You can create RAID mode by use of onboard AHCI SATA ports. To use onboard SATA ports: 1. Install all the Serial ATA hard disk drives. 2. Turning on the system. During POST, press,Del. to enter BIOS. Go to Advanced Menu > PCH SATA Configuration > SATA Mode, then press <Enter>. 3. Set SATA Mode to RAID Mode and save, then reboot system. 4. During POST, press <Ctrl+I> to display the utility main menu. To use SCU SATA ports: 1. 2. 3. 4. Install all the SATA hard disk drives. Turning on the system. During POST, press <Del> to enter BIOS. Go to Advanced Menu > PCH SCU SATA Configuration, then press <Enter>. Confirm all the SATA hard disk drives you installed are correctly displayed, then reboot system. During POST, press <Ctrl+I> to display the utility main menu. ASUS Z9PE-D8 WS 5-25 To enter the Intel® Rapid Storage Technology enterprise SCU Option ROM utility: 1. Install all the Serial ATA hard disk drives. 3. During POST, press <Ctrl+I> to display the utility main menu. 2. Turn on the system. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Exit [ DISK/VOLUME INFORMATION ] RAID Volumes: None defined. Physical Disks: ID Drive Model 0 ST3300656SS 1 ST3300656SS 2 ST3300656SS 3 ST3300656SS [↑↓]-Select Serial # HWAS0000991753TR 37VN00009846RAJ1 397600009846UEDY GWC50000991756G6 [ESC]-Exit Size Type/Status(Vol ID) 279.3GB Non-RAID Disk 279.3GB Non-RAID Disk 279.3GB Non-RAID Disk 279.3GB Non-RAID Disk [ENTER]-Select Menu The navigation keys at the bottom of the screen allow you to move through the menus and select the menu options. The RAID BIOS setup screens shown in this section are for reference only and may not exactly match the items on your screen. The utility supports maximum four hard disk drives for RAID configuration. 5-26 Chapter 5: RAID configuration 5.3.1 Creating a RAID set To create a RAID set 1. From the utility main menu, select 1. Create RAID Volume and press <Enter>. The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Volume0 RAID0(Stripe) Select Disks 128KB 0.0 GB Create Volume [ HELP ] Enter a unique volume name that has no special characters and is 16 characters or less. [↑↓]Change 2. 3. 4. [TAB]-Next [ESC]-Previous Menu [ENTER]-Select Enter a name for the RAID set and press <Enter>. When the RAID Level item is selected, press the up/down arrow key to select a RAID level to create, and then press <Enter>. When the Disks item is selected, press <Enter> to select the hard disk drives you want to include in the RAID set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model ST3300656SS ST3300656SS ST3300656SS ST3300656SS Serial # HWAS0000991753TR 37VN00009846RAJ1 397600009846UEDY GWC50000991756G6 Size 279.3GB 279.3GB 279.3GB 279.3GB Status Non-RAID Non-RAID Non-RAID Non-RAID Disk Disk Disk Disk Select 2 to 6 disks to use in creating the volume. [↑↓]-Prev/Next [SPACE]-SelectDisk [ENTER]-Done 5. Use the up/down arrow key to select a drive, and then press <Space> to select. A small triangle marks the selected drive. Press <Enter> after completing your selection. ASUS Z9PE-D8 WS 5-27 6. Use the up/down arrow keys to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press <Enter>. The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. 8. When the Capacity item is selected, enter the RAID volume capacity that you want and press <Enter>. The default value indicates the maximum allowed capacity. When the Create Volume item is selected, press <Enter>. The following warning message appears. WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N): 9. Press <Y> to create the RAID volume and return to the main menu, or <N> to go back to the CREATE VOLUME menu. 5.3.2 Creating a Recovery set To create a recovery set: 1. From the utility main menu, select 1. Create RAID Volume and press <Enter>. The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Sync: Volume0 RAID0(Stripe) Select Disks 128KB 0.0 GB N/A Create Volume [ HELP ] Enter a unique volume name that has no special characters and is 16 characters or less. [↑↓]Change 5-28 [TAB]-Next [ESC]-Previous Menu [ENTER]-Select Chapter 5: RAID configuration 2. 3. 4. Enter a name for the recovery set and press <Enter>. When the RAID Level item is selected, press the up/down arrow keys to select Recovery, and then press <Enter>. When the Disks item is selected, press <Enter> to select the hard disk drives you want to include in the recovery set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model ST3300656SS ST3300656SS ST3300656SS ST3300656SS Serial # HWAS0000991753TR 37VN00009846RAJ1 397600009846UEDY GWC50000991756G6 Size 279.3GB 279.3GB 279.3GB 279.3GB Status Non-RAID Non-RAID Non-RAID Non-RAID Disk Disk Disk Disk Select 1 Master and 1 Recovery disk to create volume. [[↑↓]-Prev/Next [TAB]-(M)aster [SPACE]-(R)ecovery [ENTER]-Done 5. 6. 7. Use the up/down arrow keys to select a drive, press <TAB> to select a Master disk, and then press <SPACE> to select a Recovery disk. A small triangle marks the selected drive. Press <Enter> after completing your selection. When the Sync item is selected, use the up/down arrow keys to select a sync option that you want and press <Enter>. When the Create Volume item is selected, press <Enter>. The following warning message appears. WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N): 8. Press <Y> to create the recovery set and return to the main menu, or <N> to go back to the CREATE VOLUME menu. If a recovery set is created, you cannot add more RAID sets even when you have more non-RAID disks installed in your system. ASUS Z9PE-D8 WS 5-29 5.3.3 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set: 1. From the utility main menu, select 2. Delete RAID Volume and press <Enter>. The following screen appears. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.0GB Status Normal Bootable Yes [ HELP ] Deleting a volume will reset the disks to non-RAID. WARNING: ALL DISK DATA WILL BE DELETED. (This does not apply to Recovery volumes) [↑↓]-Select 2. [ESC]-Previous Menu [DEL]-Delete Volume Use the up/down arrow keys to select the RAID set you want to delete, and then press <Del>. The following warning message appears. [ DELETE VOLUME VERIFICATION ] ALL DATA IN THE VOLUME WILL BE LOST! (This does not apply to Recovery volumes) Are you sure you want to delete volume “Volume0”? (Y/N): 3. 5-30 Press <Y> to delete the RAID set and return to the utility main menu, or press <N> to return to the DELETE VOLUME menu. Chapter 5: RAID configuration 5.3.4 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive: 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press <Enter>. The following screen appears. [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk. WARNING: Resetting a disk causes all data on the disk to be lost. (This does not apply to Recovery volumes) Port Drive Model 0 ST3300656SS 1 ST3300656SS Serial # HWAS0000991753TR 37VN00009846RAJ1 Size 279.3GB 279.3GB Status Member Disk Member Disk Select the disks that should be reset. [↑↓]-Previous/Next 2. 3. 4. [SPACE]-Selects [ENTER]-Selection Complete Use the up/down arrow keys to select the RAID set drive(s) you want to reset, and then press <Space> to select. Press <Enter> to reset the RAID set drive(s). A confirmation message appears. Press <Y> to reset the drive(s) or press <N> to return to the utility main menu. 5.3.5 Exiting the Intel® Rapid Storage Technology utility To exit the utility: 1. From the utility main menu, select 4. Exit, and then press <Enter>. The following warning message appears. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. Press <Y> to exit or press <N> to return to the utility main menu. ASUS Z9PE-D8 WS 5-31 5.3.6 Rebuilding the RAID This option is only for the RAID 1 set. Rebuilding the RAID with other non-RAID disk If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array with other installed non-RAID disks. To rebuild the RAID with other non-RAID disk: 1. 2. At the prompt, press <Ctrl> + <I> to enter the Intel Rapid Storage Technology option ROM utility. If there is a non-RAID SATA Hard Disk available, the utility will prompt to rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select the destination disk or press <ESC> to exit. [ DEGRADED VOLUME DETECTED ] "Degraded" volume and disk available for rebuilding detected. Selecting a disk initiates a rebuild. Rebuild completes in the operating system. Select the port of destination disk for rebuilding (ESC to exit): Port Drive Model Serial # Size X XXXXXXXXXXX XXXXXXXX XX.XGB [↑↓]-Previous/Next [ENTER]-Select [ESC]-Exit Select a destination disk with the same size as the original hard disk. 5-32 Chapter 5: RAID configuration 3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.0.0.1104 Copyright(C) 2003-11 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Exit [ DISK/VOLUME INFORMATION ] RAID Volumes: ID Name 0 Volume0 Physical Devices: Port Drive Model 1 ST3160812AS 2 ST3160812AS 5. 6. 7. Strip N/A Serial # 9LS0F4HL 3LS0JYL8 Size 149.0GB Size 149.0GB 149.0GB * = Data is Encrypted Status Bootable Rebuild Yes Type/Status(Vol ID) Member Disk(0) Member Disk(0) Volumes with “Rebuild” status will be rebuilt within the operating system. [↑↓]-Select 4. Level RAID1(Mirror) [ESC]-Exit [ENTER]-Select Menu Exit Intel Rapid Storage Technology and reboot the system. Under Microsoft® Windows OS, select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or click the Intel Rapid Storage Technology tray icon to load the Intel Rapid Storage Manager utility. From the View menu, select Advanced Mode to display the details of the Intel Rapid Storage Console. From the Volumes view option, select RAID volume to view the rebuilding status. When finished, the status is changed to “Normal”. Rebuilding the RAID with a new hard disk If any of the SATA hard disk drives included in the RAID array failed, the system displays the status of the RAID volume as “Degraded” during POST. You may replace the disk drive and rebuild the RAID array. To rebuild the RAID with a new hard disk: 1. Remove the failed SATA hard disk and install a new SATA hard disk of the same specification into the same SATA Port. Select a destination disk with the same size as the original hard disk. 2. Reboot the system and then follow the steps in section Rebuilding the RAID with other non-RAID disk. ASUS Z9PE-D8 WS 5-33 5.3.7 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID using the Intel® Rapid Storage Technology. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. 2. 3. 4. 5. 5-34 Reboot the system and press <Del> to enter the BIOS setup utility during POST. Go to the Boot menu and select the boot option priority. Use up/down arrow keys to select the boot priority and press <Enter>. See section 4.7 Boot menu for details. From the Exit menu, select Save Changes & Exit, then press <Enter>. When the confirmation window appears, select Yes, then press <Enter>. Chapter 5: RAID configuration 5.4Intel® Rapid Storage Technology enterprise Utility (Windows) The Intel® Rapid Storage Technology enterprise utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 1+0), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. Before you using Intel® Rapid Storage Technology enterprise utility, you need to change BIOS setting first: 1. 2. 3. 4. Enter the BIOS Setup during POST. Go to the Advanced Menu > Chipset Configuration > PCH Configuration> Onboard SATA Oprom, then press <Enter>. Set Onboard SATA Oprom to [Enabled]. Press <F10> to save your changes and exit the BIOS Setup. You need to manually install the Intel® Rapid Storage Technology enterprise utility on a Windows® operating system. Please refer to the installation instructions in Chapter 6. To enter the Intel® Rapid Storage Technology enterprise utility under Windows operating system: 1. 2. Turn on the system to windows desktop. Click the Intel® Rapid Storage Technology enterprise icon to display the main menu. Your storage system is configured for data protection, increased performance and optimal data storage capacity. You can further optimize your storage system by creating additional volumes. You can click Rescan to re-scan any attached hard disks. ASUS Z9PE-D8 WS 5-35 5.4.1 Creating a RAID set To create a RAID set 1. From the utility main menu, select Create Volume and select volume type. 3. Enter a name for the RAID set, then select the array disks. 5. Then click Next. 2. 4. 5-36 Then click Next. Select Volume Size tab, you can drag the bar to decide the volume size. • If you hard disk with existing data and you don’t want to keep data from one of the selected disks, choose NO in next column (If displayed). • If you want to Enable volume write-back cache or Initialize volume, you can click Advanced tab to slelect. Chapter 5: RAID configuration 6. Confirm volume creation, than click Create Volume to continue. This process could take a while depending on the number and size of the disks. You can contuine using other applications during this time. When display Volume Ceation Complete message, you can click OK to finish. You still need to partition your new volume using Windows Disk Management before adding any data. When you are finished, you will see the following screen in Volumes field and you can change related items in the Volume Properties field. ASUS Z9PE-D8 WS 5-37 5.4.2 Change Volume Type When you are finished to create a RAID set, you can view or change related items in the Volume Properties field. According to the following steps to change the type in Volume Properties: 1. Click the SAS array items you want to change in Volumes field. 3. You can change the Name, Select the new volume type, and Select additional disks to include in the new volume if needed. 2 4. From the Volume Properties field, select Type:RAID 1 Change type. Then select the Data stripe size for the RAID array (for RAID 0, 10 and 5 only), and then click OK. The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 5-38 Chapter 5: RAID configuration 5.4.3 Delete volume Take caution when deleting a volume. You will lose all data on the hard disk drives.Back up data before continuing. To delete a volume: 1. From the utility main menu, select the volume (exp. Volume_0000) in Volumes field you want to delete. 2. Then select Delete volume in Volume Properties field. The following screen appears. 3. Click Yes to delete the volume and return to the utility main menu, or click No to return to the main menu. ASUS Z9PE-D8 WS 5-39 5.4.4 Preferences System Preferences Allow you set to show the notification area icon and show system information, warning, or errors here. E-Mail Preferences Allow you set to sent e-mail of the following events: Storage system information Storage system warnings Storage system errors 5-40 Chapter 5: RAID configuration 5.5 Marvell RAID utility The onboard Marvell SATA 6.0 Gb/s controller allows you to create a RAID 0, RAID 1 or RAID 10 array using two SATA hard disk drives. Refer to Chapter 2 of your system user manual for the exact location of the Marvell SATA 6.0 Gb/s connector. To enter the Marvell utility, press <Ctrl> + <M> during POST. All exisiting data on the hard disk drives will be erased when creating or deleting a RAID array. Ensure that you have back up all your data in your hard disk drives before making any change to the drive status. Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Topology HBA 0: Marvell 0 ├ Virtual Disks └ Free Physical Disks ├ PD 0: ST3160812AS └ PD 8: ST3160812AS Information Vendor ID : Device ID : Revision ID : BIOS Version : Firmware Version: PCIe Speed Rate : Configure SATA as: ▶ Help Marvell RAID on chip controller. ENTER: Operation F10: Exit/Save 5.5.1 1. 2. 1B4B 9130 B1 1.0.0.1028 2.2.0.1105 5.0Gbps AHCI Mode ▶ ESC: Return Create a RAID Array Move the selection bar to HBA 0: Marvell 0 and press <Enter>. Select Configuration Wizard and press <Enter>. Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Configure->Select free disks HBA 0: Marvell 0 Port ID ├ Virtual Disks PD ID └ Free Physical Disks Type * ├ PD 0: ST3160812AS Status └ PD 8: ST3160812AS Size Feature Support Current Speed Model Serial FW Version : : : : : : : : : : 0 0 SATA PD Unconfigured 152626MB MCQ 3G 48Bits 3G ST3160812AS 9LS0F4HL 3.AAE ▶ ▶ Help Use space bar to select the free disks to be used in the array. ENTER: Operation SPACE: Select F10: Exit/Save ESC: Return 3. Press <Space> to select the hard drives to be included in the RAID array. An asterisk (*) appears in front of the selected hard drive. After selecting all the drives needed for the RAID array, press <Enter> to continue. ASUS Z9PE-D8 WS 5-41 Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Configure->Select free disksCreate Virtual Disk HBA 0: Marvell 0 RAID Level : RAID 0 ├ Virtual Disks Max Size(MB) : 305253 └ Free Physical Disks Stripe Size : 64KB * ├ PD 0: ST3160812AS Gigabyte Rounding : 1G * └ PD 8: ST3160812AS Quick Init : Yes Name : Default Threshold(%) : 90 Next ▶ Help ▶ Virtual disk configurations. ENTER: Select F10: Exit/Save 4. 5. ESC: Return Use the up or down arrow key to move the selection bar and press <Enter> to configure further RAID settings. RAID Level: Select a RAID Level. Configuration options: [RAID 0] [RAID 1] [RAID 10] [HyperDuo] Stripe Size: Specifies the size of single data block on the virtual disk. In general, a larger stripe size is recommended for applications requiring large data transfers such as audio, video, and graphics. A smaller stripe size is better for applications with content in much smaller size, such as e-mails and documents. Configuration options: [32K] [64K] Gigabyte Rounding: In the event of a single physical disk failure in a RAID 1 virtual disk, Gigabyte Rounding allows the replacement physical disk to be of a size slightly smaller than the existing physical disk. The capacity of the rebuilt virtual disk equals to the size of the smaller physical disk included in the RAID 1 array. The configuration options represent the tolerance value of drive capacity difference. Configuration options: [None] [1G] [10G] Name: Enter a name with 1–10 letters (no special characters) for the RAID array. Move the selection bar to Next and press <Enter>. The following warning message appears: Create Virtual Disk Do you want to create this virtual disk ? Yes 5-42 No Press <Y> to create the RAID array, or press <N> to cancel. The new RAID array appears under Virtual Disks, as shown in the image below. Chapter 5: RAID configuration Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Information Topology HBA 0: Marvell 0 ├ Virtual Disks │ └ VD 0: New_VD │ ├ PD 0: ST3160812AS │ └ PD 8: ST3160812AS └ Free Physical Disks Vendor ID : Device ID : Revision ID : BIOS Version : Firmware Version: PCIe Speed Rate : Configure SATA as: ▶ Help ▶ Marvell RAID on chip controller. ENTER: Operation F10: Exit/Save 6. 1B4B 9130 B1 1.0.0.1028 2.2.0.1105 5.0Gbps AHCI Mode ESC: Return Press <F10>. The following warning message appears: Exit Do you want to exit from Marvell BIOS Setup? Yes Press <Y> to save the RAID setting and exit the Marvell RAID utility. 5.5.2 1. No Delete an existing RAID Array Select the RAID array to delete and press <Enter>. Select Delete and press <Enter>. Marvell BIOS Setup (c) 2011 Marvell Technology Group Ltd. Topology Information HBA 0: Marvell 0 ID ├ Virtual Disks Name │ └ VD 0: New_VD Status [Delete]Stripte Size │ ├ PD 0: ST3160812AS │ └ PD 8: ST3160812AS RAID Mode └ Free Physical Disks Size BGA Status Number of PDs Members ▶ Help Delete the selected virtual disk. ENTER: Operation F10: Exit/Save ASUS Z9PE-D8 WS : : : : : : : : : 0 New_VD Functional 64K RAID0 304128MB N/A 2 0 8 ▶ ESC: Return 5-43 2. The following warning message appears: Delete Virtual Disk Do you want to delete this virtual disk ? Yes No Press <Y> to delete the selected RAID array. The following warning message appears: Delete MBR Do you want to delete MBR from this virtual disk ? Yes No Press <Y> to delete the Master Boot Record (MBR) from the selected RAID array. 3. Press <F10>. The following warning message appears: Exit Do you want to exit from Marvell BIOS Setup? Yes 5-44 No Press <Y> to save the RAID setting and exit the Marvell RAID utility. Chapter 5: RAID configuration This chapter provides the instructions for installing the necessary drivers for different system components. Chapter 6: 6 Driver installation Chapter summary 6.1 6 RAID driver installation................................................................ 6-3 6.2Intel® Chipset Device Software installation.............................. 6-14 6.3Intel@ Network Connections Software installation.................. 6-16 6.4 Audio driver installation............................................................. 6-19 6.6 Marvell Magni installation.......................................................... 6-22 6.5 Intel® C600 Series Chipset SCU SATA RAID Drivers installation................................................................................... 6-21 6.7Intel® Rapid Storage Technology enterprise 3.0 installation.. 6-23 6.8Marvell Storage Utility installation............................................ 6-26 6.9 Asmedia ASM104x USB 3.0 Host Controller Driver installation................................................................................... 6-30 6.11 VGA driver installation............................................................... 6-36 6.10Intel® WG82574L Gigabit Adapters Driver installation............. 6-33 6.12Management applications and utilities installation................. 6-39 ASUS Z9PE-D8 WS 6.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides the instructions on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk The system does not include a floppy drive. You have to use a USB floppy drive when creating a SATA RAID driver disk. If you have created RAID sets with the LSI Software RAID configuration utility, the boot priority of the SATA optical disk drive has to be manually adjusted. Otherwise, the system will not boot from the connected SATA ODD. A floppy disk with the RAID driver is required when installing Windows® XP / Server 2003 or Linux operating system on a hard disk drive that is included in a RAID set. You can create a RAID driver disk in DOS (using the Makedisk application in the support DVD). To create a RAID driver disk in DOS environment 1. Place the motherboard support DVD in the optical drive. 3. Select the optical drive as the first boot priority to boot from the support DVD. Save your changes, and then exit the BIOS Setup. 2. 4. Restart the computer, and then enter the BIOS Setup. Restart the computer. The Makedisk menu appears. Create Driver Diskette Menu C60x INTEL RAID Driver Write DMI FreeDOS command prompt 5. Use the arrow keys to select the type of RAID driver disk you want to create and press <Enter> to enter the sub-menu. C60x INTEL RAID Driver Windows Windows Windows Windows Back Exit ASUS Z9PE-D8 WS 32 64 32 64 C600 bit bit bit bit INTEL RAID Driver (AHCI / AHCI RAID) (AHCI / AHCI RAID) (SCU RAID) (SCU RAID) 6-3 LSI 2008 SAS2 Driver LSI 2008 SAS2 Driver Windows XP 32 bit Windows XP 64 bit Windows Server 2003 32 bit Windows Server 2003 64 bit Windows Vista 32 bit Windows Vista 64 bit Windows Server 2008 32 bit Windows Server 2008 64 bit Windows 7 32 bit Windows 7 64 bit Windows Server 2008 R2 64 bit RHEL 4 UP7 32 bit RHEL 4 UP7 64 bit RHEL 4 UP8 32 bit RHEL 4 UP8 64 bit Back Exit 6. 7. 8. Locate the RAID driver and place a blank, high-density floppy disk to the floppy disk drive. Press <Enter>. Follow screen instructions to create the driver disk. To create a RAID driver disk in Windows® environment: 1. Start Windows®. 2. Place the motherboard support DVD into the optical drive. 3. Go to the Make disk menu, and then select the type of RAID driver disk you want to create. 4. Insert a floppy disk into the USB floppy disk drive. 5. Follow succeeding screen instructions to complete the process. Write-protect the floppy disk to avoid computer virus infection. To create a RAID driver disk in Red Hat® Enterprise Linux server environment: 1. 2. Insert a blank formatted high-density floppy disk to the USB floppy disk drive. Type dd if=XXX.img of=/dev/fd0 to decompress the file into the floppy disk from the following path in the support DVD: For LSI MegaRAID Driver \Drivers\C60x LSI RAID\Driver\makedisk\Linux 3. Eject the floppy disk. 6-4 Chapter 6: Driver installation 6.1.2 Installing the RAID controller driver For Windows® Server 2008 OS installation To install the RAID controller driver when installing Windows® Server 2008 OS 1. 2. 3. Boot the computer using the Windows® Server 2008 OS installation disc. Follow the screen instructions to start installing Windows Server 2008. When prompted to choose a type of installation, click Custom (advanced). Click Load Driver. ASUS Z9PE-D8 WS 6-5 4. A message appears, reminding you to insert the installation media containing the driver of the RAID controller driver. If you have only one optical drive installed in your system, eject the Windows OS installation disc and replace with the motherboard Support DVD into the optical drive. Click Browse to continue. 5. Locate the driver in the corresponding folder of the Support DVD, and then click OK to continue. 6. 6-6 Select the RAID controller driver you need from the list and click Next. 7. When the system finishes loading the RAID driver, replace the motherboard Support DVD with the Windows Server installation disc. Select the drive to install Windows and click Next. 8. Setup then proceeds with the OS installation. Follow screen instructions to continue. Chapter 6: Driver installation For Red Hat® Enterprise Linux OS 5.6 To install the LSI MegaRAID controller driver when installing�������� Red Hat® Enterprise OS: 1. 2. Boot the system from the Red Hat® OS installation CD. At the boot:, type linux dd noprobe=ata1 noprobe=ata2..., then press <Enter>. The number of ata varies with the hard disk drive number you have when building a RAID set. For example, if you want to build a RAID set with 6 hard disk drives, type command line: linux dd noprobe=ata1 noprobe=ata2 noprobe=ata3 noprobe=ata4 noprobe=ata5 noprobe=ata6. - To install or upgrade in graphical mode, press the <ENTER> key. - To install or upgrade in text mode, type: linux text <ENTER>. - Use the function keys listed below for more information. [F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue] boot: linux dd noprobe=ata1 noprobe=ata2 3. Select Yes using the <Tab> key when asked if you have the driver disk, then press <Enter>. Main Menu Do you have a driver disk? Yes 4. No Insert the Red Hat® Enterprise RAID driver disk to the USB floppy disk drive, select OK, then press <Enter>. Insert Driver Disk Insert your driver disk into /dev/fd0 and press “OK” to continue. OK Back The drivers for the RAID card are installed to the system. ASUS Z9PE-D8 WS 6-7 5. When asked if you will load additional RAID controller drivers, select No, then press <Enter>. More Driver Disks? Do you wish to load any more driver disks? Yes 6. No Follow the onscreen instructions to finish the OS installation. 7. When the installation is completed, DO NOT click Reboot. Press <Ctrl> + <Alt> + <F2> to switch to the command-line interface from graphic user interface. 8. Type the following commands when using a Legacy floppy. mkdir /mnt/driver mount /dev/fd0 /mnt/driver cd /mnt/driver sh replace_ahci.sh reboot For Red Hat® Enterprise Linux OS 6.1 To install the LSI MegaRAID controller driver when installing�������� Red Hat® Enterprise OS: 1. 2. 6-8 Boot the system from the Red Hat® OS installation CD. Press <Tab> to edit options. Chapter 6: Driver installation 3. Enter the following command at the boot: Linux dd blacklist=isci blacklist=ahci nodmraid, then press <ENTER>. 4. Select Yes using the <Tab> key when asked if you have the driver disk, then press <Enter>. Main Menu Do you have a driver disk? Yes ASUS Z9PE-D8 WS No 6-9 5. You have multiple devices which could serve as source for a driver disk. Choose one you like to use and select OK, then press <Enter>. Driver Disk Source You have multiple devices which could serve as source for a driver disk. Which would you like to use? sdc sdd sdb sr0 OK 6. Cancel Insert the Red Hat® Enterprise RAID driver disk to the USB floppy disk drive, select OK, then press <Enter>. Insert Driver Disk Insert your driver disk into /dev/sdb and press “OK” to continue. OK Back The drivers for the RAID card are installed to the system. 7. When asked if you will load additional RAID controller drivers, select No, then press <Enter>. More Driver Disks? Do you wish to load any more driver disks? Yes 8. 6-10 No Follow the onscreen instructions to finish the OS installation. Chapter 6: Driver installation Preparing the Linux Driver Ensure that there is another computer with a Linux-based OS to create the RAID driver. When creating the RAID driver, you may refer to the examples below which uses a 64bit SUSE Linux system to create a 64bit RAID driver for SUSE11 sp1. 1. Copy the image file into the Linux system. 2. 3. Example: megasr-15.00.0120.2012-1-sles11-ga-x86_64.img Create a folder. Example: image Mount the image file into the image folder using this command format: mount -o loop [image file name] image Example: mount -o loop megasr-15-15.00.0120.2012-1-sles11ga-x86__64.img image 4. Copy the contents of the image directory, labeled as 01, into a FAT32 USB drive. 5. Rename the 01 folder to CD Image. ASUS Z9PE-D8 WS 6-11 Installing SUSE 11 Linux OS To install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS: 1. Boot the system from the SUSE OS installation CD. 3. Press <F6>, then select Yes from the menu. Press <Enter>. 2. 6-12 Use the arrow keys to select Installation from the Boot Options menu. Chapter 6: Driver installation 4. Use the USB drive to provide the third-party driver during the OS installation. Type the command brokenmodules=ahci in Boot Options field, and press <Enter>. 5. When below screen appears, select the USB floppy disk drive (sda) as the driver update medium. Select OK, then press <Enter>. Please choose the Driver Update medium. sda: USB Floppy other device OK 6. Back Select Back and follow the onscreen instructions to finish the installation. ASUS Z9PE-D8 WS 6-13 6.2Intel® Chipset Device Software installation This section provides the instructions on how to install the Intel® chipset device software on the system. You need to manually install the Intel® chipset device software on a Windows operating system. To install the Intel® chipset device software: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 6-14 3. Click the item Intel Chipset Device Software from the menu. 4. The Intel(R) Chipset Device Software window appears. Click Next to start installation. Chapter 6: Driver installation 5. Select Yes to accept the terms of the License Agreement and continue the process. 6. Read the Readme File Information and press Next to continue the installation. 7. Toggle Yes, I want to restart the computer npw and click Finish to complete the setup process. ASUS Z9PE-D8 WS 6-15 6.3Intel@ Network Connections Software installation This section provides the instructions on how to install the Intel® Network Connections Software on the system. You need to manually install the Intel® Network Connections Software on a Windows® operating system. To install the Intel® Network Connections Software: 1. 2. 6-16 Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. • Windows® automatically detects the LAN controllers and displays a New Hardware Found window. Click Cancel to close this window. • If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Doubleclick the ASSETUP.EXE to run the DVD. 3. Click the Intel® Network Connections Software to begin installation. 4. Click Install Drivers and Software option to begin installation. Chapter 6: Driver installation 4. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 5. Toggle I accept the terms in the license agreement and click Next to continue. 6. Click the Intel(R) PROSet for Windows Device Manager box, and then click Next to start the installation. ASUS Z9PE-D8 WS 6-17 6-18 7. Follow the screen instructions to complete installation. 8. When finished, press Finish to continue. Chapter 6: Driver installation 6.4 Audio driver installation This section provides the instructions on how to install the ASUS MIO Audio card/ Realtek High Definition Audio driver. You need to manually install the ASUS MIO Audio card/ Realtek High Definition Audio driver on a Windows® operating system. To install the ASUS MIO Audio card/ Realtek High Definition Audio driver: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 3. Click the ASUS MIO Audio card/ Realtek High Definition Audio to begin installation. 4. When the Realtek High Definition Audio Driver installation wizard appears, click Yes to start the installation. ASUS Z9PE-D8 WS 6-19 5. 6-20 When the installation completes, click Yes, I want to restart my computer now to restart your computer before using the program. Chapter 6: Driver installation 6.5Intel® C600 Series Chipset SCU SATA RAID Drivers installation This section provides the instructions on how to install the Intel® C600 Series Chipset SCU SATA RAID Drivers on the system. You need to manually install the Intel® C600 Series Chipset SCU SATA RAID Drivers on a Windows operating system. To install the drivers: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 3. Click the item Intel® C600 Series Chipset SCU SATA RAID Drivers from the menu, and then follow the onscreen instructions to complete the installation. ASUS Z9PE-D8 WS 6-21 6.6 Marvell Magni installation This section provides the instructions on how to install the Marvell Magni software on the system. You need to manually install the Marvell Magni software on a Windows operating system. To install the Marvell Magni driver: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 3. 6-22 Click the item Marvell Magni software from the menu, and then follow the onscreen instructions to complete the installation. Chapter 6: Driver installation 6.7Intel® Rapid Storage Technology enterprise 3.0 installation This section provides the instructions on how to install the Intel® Rapid Storage Technology enterprise 3.0 on the system. You need to manually install the Intel® Rapid Storage Technology enterprise 3.0 utility on a Windows® operating system. To install the Intel® Rapid Storage Technology enterprise 3.0 utility: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 3. Click the Intel® Rapid Storage Technology enterprise 3.0 to begin installation. 4. When the Welcome to the Setup Program appears, click Next to start the installation. ASUS Z9PE-D8 WS 6-23 6-24 5. Read the Warning message and click Next to continue. 6. Read the License Agreement and click Yes to continue. 7. Read the Readme File Information and click Next to continue. Chapter 6: Driver installation 8. After completing the installation, click Next to complete the setup process. 9. Select Yes, I want to restart my computer now and click Finish to restart your computer before using the program. ASUS Z9PE-D8 WS 6-25 6.8Marvell Storage Utility installation This section provides the instructions on how to install Marvell Storage Utility Driver. To install the Marvell Storage Utility on a Windows® OS: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file AUTORUN.EXE and double-click the AUTORUN.EXE and follow step 4 to run the installation. 6-26 3. Click Marvell Storage Utility. 4. When the Marvell Storage Utility installation wizard appears, click Next to start the installation. Chapter 6: Driver installation 5. Click I accept the terms in the license agreement and then click Next to continue. 6. Select the programs you want to install and click Next to continue. ASUS Z9PE-D8 WS 6-27 6-28 7. Choose the destination folder to install and click Install to start the installation. 8. The programs you selected are being installed. Chapter 6: Driver installation 9. Click Finish to complete the installation. ASUS Z9PE-D8 WS 6-29 6.9Asmedia ASM104x USB 3.0 Host Controller Driver installation This section provides the instructions on how to install Asmedia ASM104x USB 3.0 Host Controller Driver. To install the Asmedia ASM104x USB 3.0 Host Controller Driver on a Windows® OS: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file AUTORUN.EXE and double-click the AUTORUN. EXE and follow step 4 to run the installation. 3. 6-30 Click Asmedia ASM104x USB 3.0 Host Controller Driver. Chapter 6: Driver installation 4. When the Asmedia ASM104x USB 3.0 Host Controller Driver installation wizard appears, click Next to start the installation. 5. Click I accept the terms in the license agreement and then click Next to continue. ASUS Z9PE-D8 WS 6-31 6. 6-32 Click Finish to complete the installation and exit the wizard. Chapter 6: Driver installation 6.10Intel® WG82574L Gigabit Adapters Driver installation This section provides the instructions on how to install the Intel® WG82574L Gigabit Adapters Driver. To install the Intel® WG82574L Gigabit Adapters Driver on a Windows® OS: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file AUTORUN.EXE and double-click the AUTORUN.EXE and follow step 4 to run the installation. 3. Click Intel® WG82574L Gigabit Adapters Driver. 4. When the Intel® WG82574L Gigabit Adapters Driver installation wizard appears, click Next to start the installation. ASUS Z9PE-D8 WS 6-33 6-34 5. Click Modify to change custom setup and then click Next to continue. 6. Select the programs you want to install and click Next to continue. Chapter 6: Driver installation 7. Click Install to begin installation. 8. Click Finish to complete the installation. ASUS Z9PE-D8 WS 6-35 6.11 VGA driver installation This section provides the instructions on how to install the ASPEED Video Graphics Adapter (VGA) driver. • ASPEED SDT2300 Display Driver will only appear if you use the onboard VGA chipset. • You need to manually install the ASPEED VGA driver on a Windows® operating system. To install the ASPEED VGA driver: 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 6-36 3. Click the ASPEED AST2300 Display Driver to begin installation. 4. When the ASPEED Graphics installation wizard appears, click Next to start the installation. Chapter 6: Driver installation 5. Toggle I accept the terms in the license agreement and click Next to continue. 6. Enter the user information and click Next to continue. 7. Select a setup type and click Next to continue. ASUS Z9PE-D8 WS 6-37 6-38 8. Click Install to start driver installation. 9. When the installation completes, click Finish to restart your computer before using the program. Chapter 6: Driver installation 6.12Management applications and utilities installation The support DVD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 6.12.1 Running the support DVD Place the support DVD to the optical drive. The DVD automatically displays the Drivers menu if Autorun is enabled in your computer. If Autorun is NOT enabled in your computer, browse the contents of the support DVD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the support DVD. 6.12.2 Drivers menu The Drivers menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices. The screen display and driver options vary under different operating system versions. ASUS Z9PE-D8 WS 6-39 6.12.3 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install. 6.12.4 Make disk menu The Make disk menu contains items to create the Intel RAID driver disks. 6.12.5 Contact information Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide. 6-40 Chapter 6: Driver installation This chapter describes how to install and configure multiple AMD® CrossFireX™/ NVIDIA® SLI™ graphics cards and NVIDIA® CUDA technology. Chapter 7: 7 Multiple GPU technology support Chapter summary 7 7.1 AMD® CrossFireX™ technology.................................................. 7-3 7.3 NVIDIA® CUDA™ technology..................................................... 7-13 7.2 NVIDIA® SLI™ technology............................................................ 7-7 ASUS Z9PE-D8 WS 7.1��� AMD® CrossFireX™� ���������� technology The motherboard supports the AMD® CrossFireX™ technology that allows you to install multi-graphics processing units (GPU) graphics cards. Follow the installation procedures in this section. 7.1.1 • • • Requirements In Dual CrossFireX mode, you should have two identical CrossFireX-ready graphics cards or one CrossFireX-ready dual-GPU graphics card that are AMD® certified. Ensure that your graphics card driver supports the AMD CrossFireX technology. Download the latest driver from the AMD website (www.amd. com). Ensure that your power supply unit (PSU) can provide at least the minimum power required by your system. �������������������������� See Chapter 2 for details. 7.1.2 • We recommend that you install additional chassis fans for better thermal environment. • Visit the AMD Game website (http://game.amd.com) for the latest certified graphics card and the supported 3D application list. Before you begin For AMD CrossFireX to work properly, you have to uninstall all existing graphics card drivers before installing AMD CrossFireX graphics cards to your system. To uninstall existing graphics card drivers: 1. Close all current applications. For Windows 7, go to Control Panel > Programs > Programs and Features. 2. 3. 4. 5. For Windows XP, go to Control Panel > Add/Remove Programs. Select your current graphics card driver/s. For Windows XP, select Add/Remove. For Windows 7, select Uninstall. Turn off your computer. ASUS Z9PE-D8 WS 7-3 7.1.3����������������������������������������� Installing two CrossFireX™��������������� graphics cards The following pictures are for reference only. The graphics cards and the motherboard layout may vary with models, but the installation steps remain the same. 1. 2. 3. 4. Prepare two CrossFireX-ready graphics cards. Insert the two graphics card into the PCIEX16 slots. If your motherboard has more than two PCIEX16 slots, refer to Chapter 2 in this user manual for the locations of the PCIEX16 slots recommended for multi-graphics card installation. Ensure that the cards are properly seated on the slots. Align and firmly insert the CrossFireX bridge connector to the goldfingers on each graphics card. Ensure that the connector is firmly in place. CrossFireX bridge (bundled with graphics cards) Goldfingers 5. Connect two independent auxiliary power sources from the power supply to the two graphics cards separately. 6. 7-4 Connect a VGA or a DVI cable to the graphics card. Chapter 7: Multiple GPU technology support 7.1.4 Installing the device drivers Refer to the documentation that came with your graphics card package to install the device drivers. Ensure that your PCI Express graphics card driver supports the AMD® CrossFireX™ technology. Download the latest driver from the AMD website (www.amd.com). 7.1.5 Enabling the AMD® CrossFireX™ technology After installing your graphics cards and the device drivers, enable the CrossFireX™ feature through the AMD Catalyst™ Control Center in Windows environment. Launching the AMD VISION Engine Control Center To launch the AMD VISION Engine Control Center: 1. Right-click on the Windows® desktop and select AMD VISION Engine Control Center. You can also right-click the AMD icon in the Windows notificAMDon area and select Vision Engine Control Center. 2. The VISION Engine Control Center Setup Assistant appears when the system detects the existance of multi-graphics cards. Click Go to continue to the VISION Engine Control Center Advanced View window. ASUS Z9PE-D8 WS 7-5 Enabling Dual CrossFireX technology 1. 2. 3. 4. 7-6 3 In the Catalyst Control Center window, click Graphics Settings > Performance > AMD CrossFireXTM Configuration. From the Graphics Adapter list, select the graphics card to act as the display GPU. Select Enable CrossFireXTM. 2 3 1 4 Click Apply, and then click OK to exit the window. Chapter 7: Multiple GPU technology support 7.2 NVIDIA® SLI™ technology The motherboard supports the NVIDIA® SLI™ (Scalable Link Interface) technology that allows you to install multi-graphics processing units (GPU) graphics cards. Follow the installation procedures in this section. 7.2.1 • • • • Requirements In Dual SLI mode, you should have two identical SLI-ready graphics cards that are NVIDIA® certified. In Triple SLI mode, you should have three identical SLI-ready graphics cards that are NVIDIA® certified. Ensure that your graphics card driver supports the NVIDIA SLI technology. Download the latest driver from the NVIDIA website (www.nvidia.com). Ensure that your power supply unit (PSU) can provide at least the minimum power required by your system. 7.2.2 • We recommend that you install additional chassis fans for better thermal environment. • Visit the NVIDIA zone website (http://www.nzone.com) for the latest certified graphics card and supported 3D application list. Installing two SLI-ready graphics cards The following pictures are for reference only. The graphics cards and the motherboard layout may vary with models, but the installation steps remain the same. 1. Prepare two SLI-ready graphics cards. 2. 3. Insert the two graphics card into the PCIEX16 slots. If your motherboard has more than two PCIEX16 slots, refer to Chapter 2 in this user manual for the locations of the PCIEX16 slots recommended for multi-graphics card installation. Ensure that the cards are properly seated on the slots. ASUS Z9PE-D8 WS 7-7 4. Align and firmly insert the SLI bridge connector to the goldfingers on each graphics card. Ensure that the connector is firmly in place. 5. Connect two independent auxiliary power sources from the power supply to the two graphics cards separately. 6. Connect a VGA or a DVI cable to the graphics card. SLI bridge Goldfingers 7.2.3 Installing three SLI-ready graphics cards 1. Prepare three SLI-ready graphics cards. 2. 3. 4. Insert the three graphics card into the PCIEX16 slots. If your motherboard has more than two PCIEX16 slots, refer to Chapter 2 in this user manual for the locations of the PCIEX16 slots recommended for multi-graphics card installation. Ensure that the cards are properly seated on the slots. Align and firmly insert the 3Way SLI bridge connector to the goldfingers on each graphics card. Ensure that the connector is firmly in place. 5. Connect three independent auxiliary power sources from the power supply to the three graphics cards separately. 6. 7-8 Connect a VGA or a DVI cable to the graphics card. 3-Way SLI bridge Chapter 7: Multiple GPU technology support 7.2.4 Installing four SLI-ready graphics cards 1. Prepare four SLI-ready graphics cards. 2. 3. 4. Insert the four graphics card into the PCIEX16 slots. If your motherboard has more than two PCIEX16 slots, refer to Chapter 2 in this user manual for the locations of the PCIEX16 slots recommended for multi-graphics card installation. Ensure that the cards are properly seated on the slots. Align and firmly insert the 4-Way SLI bridge connector to the goldfingers on each graphics card. Ensure that the connector is firmly in place. 5. Connect four independent auxiliary power sources from the power supply to the four graphics cards separately. 6. Connect a VGA or a DVI cable to the graphics card. 4-Way SLI bridge ASUS Z9PE-D8 WS 7-9 7.2.5 Installing the device drivers Refer to the documentation that came with your graphics card package to install the device drivers. 7.2.6 • Ensure that your PCI Express graphics card driver supports the NVIDIA® SLI™ technology. Download the latest driver from the NVIDIA website at www.nvidia.com. • If you are using a Triple SLI system, ensure to install the NVIDIA® 3-way SLI driver under Windows® Vista™. The NVIDIA 3-way SLI technology is supported by Windows® Vista™ only. Enabling the NVIDIA® SLI™ technology After installing your graphics cards and the device drivers, enable the SLI feature in NVIDIA® Control Panel under the Windows® 7™ operating system. Launching the NVIDIA Control Panel You can launch the NVIDIA Control Panel by the following two methods. A. 7-10 Right click on the empty space of the Windows® desktop and select NVIDIA Control Panel. The NVIDIA Control Panel window appears (See Step B5). Chapter 7: Multiple GPU technology support B1. If you cannot see the NVIDIA Control Panel item in step (A), select Personalize. B2. From the Personalization window, select Display Settings. B3. From the Display Settings dialog box, click Advanced Settings. ASUS Z9PE-D8 WS 7-11 B4. Select the NVIDIA GeForce tab, and then click Start the NVIDIA Control Panel. B5. The NVIDIA Control Panel window appears. Enabling SLI settings From the NVIDIA Control Panel window, select Set SLI Configuration. Click Enable SLI and set the display for viewing SLI rendered content. When done, click Apply. 7-12 Chapter 7: Multiple GPU technology support 7.3 NVIDIA® CUDA™ technology The motherboard supports the NVIDIA® CUDA™ technology and up to 4 NVIDIA® Telsa™ computing processor cards, providing the optimum multi purpose computing performance. Follow the installation procedures in this section. 7.3.1 • • Requirements 32/64-bit Microsoft® Windows XP/ Vista/ Linux RHEL5.X/ Open SuSE11.X OS The requirements of memory and power supply vary with the Telsa cards you installed. 7.3.2 • We recommend that you install additional chassis fans for better thermal environment. • The installation steps might be a little different with the Telsa cards you selected and the VGA output functions. Visit http://www.nvidia.com for more details if needed. • Visit the NVIDIA CUDA Zone website at http://www.nvidia.com/object/ cuda_home.html for the latest driver, list of CUDA-certified graphics card and supported 3D application list. Installing CUDA-ready graphics cards The following pictures are for reference only. The graphics cards and the motherboard layout may vary with models, but the general installation steps remain the same. 1. Insert four Tesla computing processor card(s) into the PCIe x16_1, PCIe x16_2, PCIe x16_3, and PCIe x16_4 slot. Ensure that the cards are properly seated on the slot. ASUS Z9PE-D8 WS 7-13 2. 3. Connect either one 8-pin power connector or two 6-pin power connectors from the power supply to the Quadro graphics card and Tesla computing processor card(s). Connect a display cable to the graphics card. SLI bridge Goldfingers 4. 5. Refer to the documentation that came with your graphics card package to install the device drivers. To verify graphics card driver installation, right-click My Computer and select Properties from the menu. Click the Hardware tab, and then click Device Manager. Click the “+” sign before Display adapters, and the installed graphics card and computing processor card(s) should appear. The screen differs based on the components you installed. 7-14 Chapter 7: Multiple GPU technology support This appendix includes additional information that you may refer to when configuring the motherboard. Appendix: A Reference information Appendix summary A.1 A Z9PE-D8 WS block diagram.........................................................A-3 ASUS Z9PE-D8 WS A.1 Z9PE-D8 WS block diagram ASUS Z9PE-D8 WS A-3 A-4 Appendix A: Reference information ASUS contact information ASUSTeK COMPUTER INC. (Taiwan) Address Telephone Fax E-mail Web site Technical Support Telephone Online Support 15 Li-Te Road, Peitou, Taipei, Taiwan 11259 +886-2-2894-3447 +886-2-2890-7798 [email protected] http://www.asus.com.tw +886-2-2894-3447 (0800-093-456) http://support.asus.com/techserv/techserv.aspx ASUSTeK COMPUTER INC. (China) Address Telephone Fax Web site Technical Support Telephone Online Support No.508, Chundong Road, Xinzhuang Industrial Zone, Minhang District, Shanghai, China. +86-21-5442-1616 +86-21-5442-0099 http://www.asus.com.cn +86-21-3407-4610 (800-820-6655) http://support.asus.com/techserv/techserv.aspx ASUS COMPUTER INTERNATIONAL (America) Address 800 Corporate Way, Fremont, CA 94539, USA Fax +1-510-608-4555 Web site http://usa.asus.com Technical Support Support fax +1-812-284-0883 General support +1-812-282-2787 Online support http://support.asus.com/techserv/techserv.aspx ASUS COMPUTER GmbH (Germany and Austria) Address Fax Web site Online contact Harkort Str. 21-23, D-40880 Ratingen, Germany +49-2102-959911 http://www.asus.de http://www.asus.de/sales Technical Support Telephone +49-1805-010923* Support Fax +49-2102-959911 Online support http://support.asus.com/techserv/techserv.aspx * EUR 0.14/minute from a German fixed landline; EUR 0.42/minute from a mobile phone. (510)739-3777/(510)608-4555 800 Corporate Way, Fremont, CA 94539. Asus Computer International Date : Signature : Representative Person’s Name : Feb. 03, 2011 Steve Chang / President This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Supplementary Information: FCC Part 15, Subpart E, Intentional Radiators FCC Part 15, Subpart C, Intentional Radiators FCC Part 15, Subpart B, Unintentional Radiators Model Number : Z9PE-D8 WS Conforms to the following specifications: Product Name : Motherboard hereby declares that the product Phone/Fax No: Address: Responsible Party Name: Per FCC Part 2 Section 2. 1077(a) DECLARATION OF CONFORMITY Ver. 110101 Manufacturer: HARKORT STR. 21-23, 40880 RATINGEN Address, City: Model name : EN 62301:2005 Declaration Date: Feb. 03, 2012 Year to begin affixing CE marking:2012 CE marking EN 62301:2005 Regulation (EC) No. 642/2009 Signature : __________ Position : CEO Name : Jerry Shen (EC conformity marking) EN 62301:2005 Regulation (EC) No. 278/2009 EN 60065:2002 / A12:2011 Regulation (EC) No. 1275/2008 2009/125/EC-ErP Directive EN 60065:2002+A1:2006+A11:2008 EN 60950-1 / A12:2011 EN 301 489-1 V1.8.1(2008-04) EN 301 489-3 V1.4.1(2002-08) EN 301 489-4 V1.3.1(2002-08) EN 301 489-7 V1.3.1(2005-11) EN 301 489-9 V1.4.1(2007-11) EN 301 489-17 V2.1.1(2009-05) EN 301 489-24 V1.4.1(2007-09) EN 302 326-2 V1.2.2(2007-06) EN 302 326-3 V1.3.1(2007-09) EN 301 357-2 V1.3.1(2006-05) EN 302 623 V1.1.1(2009-01) EN 55024:2010 EN 61000-3-3:2008 EN 55020:2007 EN 60950-1 / A11:2009 2006/95/EC-LVD Directive EN 300 328 V1.7.1(2006-10) EN 300 440-1 V1.4.1(2008-05) EN 300 440-2 V1.2.1(2008-03) EN 301 511 V9.0.2(2003-03) EN 301 908-1 V3.2.1(2007-05) EN 301 908-2 V3.2.1(2007-05) EN 301 893 V1.4.1(2005-03) EN 302 544-2 V1.1.1(2009-01) EN 50360:2001 EN 50371:2002 EN 50385:2002 1999/5/EC-R &TTE Directive EN 55022:2010 EN 61000-3-2:2006+A1:2009+A2:2009 EN 55013:2001+A1:2003+A2:2006 conform with the essential requirements of the following directives: 2004/108/EC-EMC Directive Motherboard Z9PE-D8 WS Product name : declare the following apparatus: Ver. 111121 ASUS COMPUTER GmbH Authorized representative in Europe: GERMANY TAIWAN Country: Country: No. 150, LI-TE RD., PEITOU, TAIPEI 112, TAIWAN R.O.C. Address, City: ASUSTek COMPUTER INC. EC Declaration of Conformity We, the undersigned,
advertisement
Key Features
- Intel LGA 2011 (Socket R) Intel® Xeon®
- PC SSI EEB 7.1 channels
- DDR3-SDRAM Non-ECC Maximum internal memory: 64 GB
- 4-Way SLI, Quad-GPU CrossFireX
- BIOS type: UEFI 64 Mbit ACPI version: 2.0a
- Gigabit Ethernet