INSTALLATION GUIDE
AXIS Electrical Safety Kit A 120 V AC
ENGLISH
AXIS Electrical Safety Kit B 230 V AC
FRANÇAIS
DEUTSCH
ITALIANO
ESPAÑOL
Electrical Safety: Low Voltage Directive
(LVD)
Europe This equipment complies with
the Low Voltage Directive 2006/95/EC.
Safety
For safety information regarding the
components of this kit, see Technical
Specifications, on page 15.
Equipment Modifications
This equipment must be installed and used in
strict accordance with the instructions given in
the user documentation. This equipment
contains no user-serviceable components.
Unauthorized equipment changes or
modifications will invalidate all applicable
regulatory certifications and approvals.
Liability
Every care has been taken in the preparation of
this document. Please inform your local Axis
office of any inaccuracies or omissions. Axis
Communications AB cannot be held responsible
for any technical or typographical errors and
reserves the right to make changes to the
product and documentation without prior
notice. Axis Communications AB makes no
warranty of any kind with regard to the material
contained within this document, including, but
not limited to, the implied warranties of
merchantability and fitness for a particular
purpose. Axis Communications AB shall not be
liable nor responsible for incidental or
consequential damages in connection with the
furnishing, performance or use of this material.
This product is only to be used for its intended
purpose.
RoHS
This product complies with both the
European RoHS directive, 2002/95/EC,
and the Chinese RoHS regulations, ACPEIP.
WEEE Directive
The European Union has enacted a
Directive 2002/96/EC on Waste
Electrical and Electronic Equipment
(WEEE Directive). This directive is applicable in
the European Union member states. The WEEE
marking on this product (see right) or its
documentation indicates that the product must
not be disposed of together with household
waste. To prevent possible harm to human
health and/or the environment, the product
must be disposed of in an approved and
environmentally safe recycling process. For
further information on how to dispose of this
product correctly, contact the product supplier,
or the local authority responsible for waste
disposal in your area. Business users should
contact the product supplier for information on
how to dispose of this product correctly. This
product should not be mixed with other
commercial waste. For more information, visit
www.axis.com/techsup/.
Support
Should you require any technical assistance,
please contact your Axis reseller. If your
questions cannot be answered immediately, your
reseller will forward your queries through the
appropriate channels to ensure a rapid response.
If you are connected to the Internet, you can:
• download user documentation and firmware
updates
• find answers to problems in the FAQ database.
Search by product, category, phrases.
• report problems to Axis support by logging in
to your private support area.
Safeguards
Please read through this Installation Guide carefully before installing the
Axis product. Keep the Installation Guide for further reference.
•
•
•
•
•
•
•
•
This Axis product shall be used in compliance with local laws
and regulations.
The Axis product should be installed by a trained professional.
Observe relevant national and local regulations for the installation.
Transportation
•
When transporting the Axis product, use the original packaging
or equivalent to prevent damage to the product.
ENGLISH
•
Store the Axis product in a dry and ventilated environment.
Avoid exposing the Axis product to vibration, shocks or heavy
pressure. Do not install the product on unstable brackets,
unstable or vibrating surfaces or walls, since this could cause
damage to the product.
Only use applicable tools when installing the Axis product;
excessive force could cause damage to the product.
Do not use chemicals, caustic agents, or aerosol cleaners. Use a
damp cloth for cleaning.
Use only accessories that comply with technical specification of
the product. These can be provided by Axis or a third party.
Use only spare parts provided by or recommended by Axis.
Do not attempt to repair the product by yourself, contact Axis
or your Axis reseller for service matters.
AXIS Electrical Safety Kit A/B
Page 5
AXIS Electrical Safety Kit A/B
Installation Guide
This Installation Guide provides instructions for installing AXIS Electrical
Safety Kit A 120 V AC and AXIS Electrical Safety Kit B 230 V AC in AXIS
T98A-VE Surveillance Cabinet Series.
Installation steps
1.
2.
3.
4.
Check the package contents against the list below.
Hardware overview on page 6.
Connection diagram on page 7.
Install the devices on page 9.
• Install the door switch on page 12.
Package contents
Item
Models/variants/notes
Circuit breaker/
Fuse
MCB fuse 4 A
Terminal block
Terminal block – ground (green/yellow) (2x)
Terminal block – feed-through (blue)
Surge protector
Surge protector Class_2
Door switch
Door switch with mounting screw
Cable
Door switch cable with cable clip
Printed
Materials
AXIS Electrical Safety Kit A/B Installation Guide
(this document)
ENGLISH
The purpose of this kit is to provide surge protection, a fuse and an
alarm-door switch to detect intrusion or vandalism of the cabinet.
Page 6
AXIS Electrical Safety Kit A/B
Hardware Overview
1
2
3
4
5
6
7
1
2
3
4
5
6
7
MCB fuse 4 A (Circuit breaker)
Surge protector 4 A
Terminal block – feed-through (blue)
Terminal block – ground (green/yellow)
Terminal block – ground (green/yellow)
Door switch
Door switch cable
In this document PE, Protective Earth, and Ground are referred to as
ground.
AXIS Electrical Safety Kit A/B
Page 7
Connection Diagram
DOOR SWITCH
CIRCUIT BREAKER/
FUSE 4 A
5
1
L1
N
N1
INCOMING
MAINS VOLTAGE
L
2
N
SURGE PROTECTOR
230 V AC
or
120 V AC
3
TO
POWER
SUPPLIES
PE
EXTERNAL PROTECTIVE
BONDING WIRE
1
2
3
4
5
MCB fuse 4 A (circuit breaker) L
Incoming mains voltage
N
Surge protector
PE
To power supplies
Door switch
•
4
PE1
TT - TNS - TNC - IT
Line
Neutral
Protective earth (ground)
Ground
If an external protective bonding wire is used it is recommended to have a miminum area of 6 mm2 (AWG 10) for indoor
•
•
use and a minimum area of 10 mm2 (AWG 8) for outdoor use.
The circuitry shall be connected to an external double pole circuit breaker in the building installation.
The door switch shall only be used for signal voltage (SELV) and
shall not be connected to the mains voltage or power supply.
ENGLISH
L
Page 8
•
•
AXIS Electrical Safety Kit A/B
Check the surge protector after lightning strikes and replace if
required. See Replace the Surge Protector, on page 14.
An additional fuse may be required in regions with severe lightning strikes. To prevent unwanted triggering of the fuse, a
higher rated fuse may replace the 4 A MCB fuse, following local
regulations. In this case, put the 4 A MCB fuse after the surge
protector.
AXIS Electrical Safety Kit A/B
Page 9
Install the Devices
•
•
•
1.
2.
3.
4.
Keep the wires short but do not stretch them. Short wires give
better surge protection than long wires.
• The ground wire should be as short as possible and have as
large cross section as possible. Attach the ground wire to a
suitable grounding point, for example an earth stake.
Snap on the fuse, surge protector and terminal blocks on the DIN
rail. See Hardware Overview, on page 6 and the examples on
page 10. Make sure that the positions correspond to the slots in the
device cover.
See the User Guide provided with the surveillance cabinet for more
information about the device cover.
Connect the devices according to the connection diagram. See
page 7. Use a cable of minimum 2.5 mm2 (AWG 14) for incoming
mains voltage.
Secure the cables. Use 2.8 Nm (25 lb-in) torque for the screw
terminals.
Attach the device cover to the cabinet base according to the
instructions provided with the surveillance cabinet.
ENGLISH
The electrical connections and conduit installations shall be
made by a certified electrician and in compliance with local
regulations.
Risk of electric shock. The mains supply shall be disconnected
during installation.
Page 10
AXIS Electrical Safety Kit A/B
Example: AXIS Electrical Safety Kit A 120 V AC
1 2 3 4 5
L
PE
1
0
4A
N
6
1
2
3
4
5
6
7
8
9
L
N
7 8 9
Circuit breaker
Surge protector
Terminal block – feed-through (blue)
Terminal block – ground (green/yellow)
Terminal block – ground (green/yellow)
Line connection
Neutral connection
Ground connection
External ground connection
AXIS Electrical Safety Kit A/B
Page 11
Example: AXIS Electrical Safety Kit B 230 V AC
1 2 3 4 5
L
N
PE
6
1
2
3
4
5
6
7
8
9
L
N
7 8 9
Circuit breaker
Surge protector
Terminal block – feed-through (blue)
Terminal block – ground (green/yellow)
Terminal block – ground (green/yellow)
Line connection
Neutral connection
Ground connection
External ground connection
ENGLISH
1
0
4A
Install the Door Switch
The door switch included with the electrical safety kit can be connected
to the I/O port on a camera or an I/O device. See the camera’s
Installation Guide and User Manual for information about connecting
and configuring the camera’s I/O port.
1.
Connect either of the connectors on the door switch cable to the
common terminal on the door switch.
Connect the other connector on the door switch cable to either of
the terminals on the door switch, depending on the desired function
of the switch.
Put the door switch in the slot on the cabinet door and secure it
with the supplied screw.
2.
3.
7
2
3
4
1
6
5
Example image: AXIS T98A15-VE/T98A18-VE
1
2
3
4
Door switch cable
Common terminal
Terminal (NO)
Terminal (NC)
4
5
6
Screw
Cabinet door
Actuator
AXIS Electrical Safety Kit A/B
4.
5.
6.
Page 13
If connecting to the I/O port on a camera, route the door switch
cable through a cable gasket and attach the cable gasket to one of
the cable holes in the cabinet door.
Secure the cable to the door using the supplied cable clip.
Connect the door switch cable to the I/O port on the camera or the
I/O device.
7.
Close the cabinet and make sure the switch is activated when the
door is closed and released when the door is opened. If necessary
bend the actuator.
ENGLISH
See the camera’s Installation Guide and User Manual for
information about connecting and configuring the camera’s I/O
port.
Page 14
AXIS Electrical Safety Kit A/B
Replace the Surge Protector
The surge protector gets worn out by surges. The window on the surge
protector shows the status of the device.
1.
When the entire window is red, pull out the module and replace it.
alarm
res
on
alarm
res
on
AXIS Electrical Safety Kit A/B
Page 15
Technical Specifications
General
Item
Specifications
General
Environment
In a casing for indoor or outdoor use
Pollution
Degree
2
Approvals
EN61058
UL1054
Operating
conditions
-40 ºC to +85 ºC (-40 ºF to 185 ºF)
Humidity 15 – 100% RH
Approvals
UL1059
CSA C22.2 No. 158
EN 60947-1
EN 60947-7-1
Door switch
Terminal
blocks
ENGLISH
Function/group
Page 16
AXIS Electrical Safety Kit A/B
AXIS Electrical Safety Kit A 120 V AC
Function/group
Item
Specifications
Circuit
breaker/fuse
Rated current
4A at 30°C (86°F)
Operating
voltage
Max 277 V AC
Rated
frequencey
50/60 Hz
Rated short10 kA
circuit capacity
Surge
protective
device
Tripping curve
K
Approvals
IEC/EN 60947-2
UL 489
CSA 22.2 No. 5
Operating
conditions
-40 ºC to +75 ºC (-40 ºF to 167 ºF)
Humidity 15 – 100% RH
Class
2
Nominal
voltage
120 V AC
Max discharge
current Imax
(8/20)
40 kA
Approvals
IEC 61643-1 Ed2
UL 1449 Ed3
Operating
conditions
-40 ºC to +80 ºC (-40 ºF to 176 ºF)
Humidity 15 – 100% RH
AXIS Electrical Safety Kit A/B
Page 17
AXIS Electrical Safety Kit B 230 V AC
Item
Specifications
Circuit
breaker/fuse
Rated current
4A at 30°C (86°F)
Operating
voltage
Max 253 V AC
Rated
frequencey
50/60 Hz
Rated short6 kA
circuit capacity
Surge
protective
device
Tripping curve
C
Approvals
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
CSA 22.2 No. 235
Operating
conditions
-40 ºC to +75 ºC (-40 ºF to 167 ºF)
Humidity 15 – 100% RH
Class
2
Nominal
voltage
230 V AC
Max discharge
current Imax
(8/20)
40 kA
Approvals
IEC 61643-1
EN 61643-11
Operating
conditions
-40 ºC to +80 ºC (-40 ºF to 176 ºF)
Humidity 15 – 100% RH
ENGLISH
Function/group
Page 18
AXIS Electrical Safety Kit A/B
Warranty
For information about Axis’ product warranty and thereto related
information, see www.axis.com/warranty
Installation Guide
AXIS Electrical Safety Kit A/B
© Axis Communications AB, 2012
Ver.2.10
Printed: October 2012
Part No. 48993
Download PDF

advertising