364834-YTG-C-0708
DESCRIPTION
The 13 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be custom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal
applications to provide a complete system. Electric Heaters
are available, if required. Add-on coils are available for use
with upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
TECHNICAL GUIDE
Single Phase Units:
5-year limited parts warranty.
10-year limited compressor warranty.
SPLIT-SYSTEM
AIR CONDITIONERS
FEATURES
13 SEER – R-410A
MODELS:
YCJD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
LISTED
ISO 9001
Certified Quality
Management System
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
• QUALITY CONDENSER COILS - The coil is constructed
of aluminum microchannel tubing and enhanced aluminum
fins for increased efficiency and corrosion protection.
• PROTECTED COMPRESSOR - The compressor is internally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This
is accomplished by the simultaneous operation of high
pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions
occur. A liquid line filter-drier further protects the compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connections. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
• EASY SERVICE ACCESS - Fully exposed refrigerant connections, and a single panel covering the electrical controls make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
364834-YTG-C-0708
Physical and Electrical Data
YCJD18
S41S1(H)
MODEL
YCJD24
S41S1(H)
YCJD30
S41S1(H)
Unit Supply Voltage
Normal Voltage Range
2
Min. Overcurrent Device Amps 3
Compressor Type
10.0
12.4
14.7
17.9
21.5
21.1
34.3
15
20
25
30
35
35
60
15
15
15
20
25
25
35
Rotary
Recip
Recip
Recip
Recip
Recip
Scroll
7.6
9.3
10.6
13.1
16.0
15.7
26.2
Locked Rotor
40.0
43.0
54.0
74
84
84
150
No
No
No
No
No
No
No
1.5
Rated Load
0.5
0.8
1.4
1.5
1.5
1.5
17.5
17.5
17.5
22
22
22
24
Rated HP
1/12
1/8
1/4
1/4
1/4
1/4
1/4
Nominal RPM
1100
1075
1100
850
850
850
850
Nominal CFM
1400
1950
2050
3200
2950
2950
3600
Face Area Sq. Ft.
9.60
9.60
9.60
13.07
14.16
14.16
18.68
Fan Diameter Inches
Coil
YCJD60
S41S1
Rated Load
Crankcase Heater
Fan Motor
YCJD48
S41S1(H)
187 to 252
Max. Overcurrent Device Amps
Fan Motor Amps
YCJD42
S41S1(H)
208-230V, 1φ, 60Hz
1
Minimum Circuit Ampacity
Compressor Amps
YCJD36
S41S1(H)
Rows Deep
1
1
1
1
1
1
1
Fin / Inches
23
23
23
23
23
23
23
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
5/8
3/4
3/4
3/4
7/8
7/8
7/8
3-3
3 - 13
3 - 14
4-9
4-5
4-9
5-6
Charge Per Foot, Oz.
0.58
0.62
0.62
0.62
0.67
0.67
0.67
Operating Weight Lbs.
97
129
131
145
173
173
195
Unit Charge (Lbs. - Oz.)
4
Models with “H” on the end of the model number have a factory installed start kits.
1. Rated in accordance with ARI Standard 110, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15
feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.
C
Unit
Model
A
B
2
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A1
B
C
18
28
23-1/2
23-1/2
24
28
23-1/2
23-1/2
30
28
23-1/2
23-1/2
36
28
29
29
42
30
29
29
48
30
29
29
60
32
33-5/8
33-5/8
Liquid
Vapor
3/4”
3/8”
7/8”
1. Including Fan Guard.
Johnson Controls Unitary Products
364834-YTG-C-0708
Additional R-410A Charge / Orifice Size for Various Matched Systems
Outdoor Unit
Required Orifice or TXV 1,2
Factory Charge, lbs-oz
YCJD18
S41S1(H)
YCJD24
S41S1(H)
YCJD30
S41S1(H)
YCJD36
S41S1(H)
YCJD42
S41S1(H)
YCJD48
S41S1(H)
YCJD60
S41S1
0.048 / 902
0.055 / 902
0.061 / 907
0.065 / 903
0.075 / 903
0.073 / 904
0.087 / 905
3-3
3 - 13
3 - 14
4-9
4-5
4-9
5-6
48 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
48 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
–
55 + 4
61 + 0
–
–
–
–
–
902 + 4
907 + 0
–
–
–
–
–
55 + 4
61 + 0
–
–
–
–
–
902 + 4
907 + 0
–
–
–
–
–
55 + 4
61 + 0
–
–
–
–
–
902 + 4
907 + 0
–
–
–
–
–
55 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
55 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
55 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
55 + 4
61 + 2
65 + 0
–
–
–
–
902 + 4
907 + 2
903 + 0
–
–
–
–
55 + 4
61 + 2
65 + 0
75 + 0
–
–
–
902 + 4
907 + 2
903 + 0
903 + 0
–
–
–
55 + 4
61 + 2
65 + 0
75 + 0
–
–
Indoor Coil3,4
FC/MC/PC/UC18A3X
FC/MC/PC/UC18B3X
FC/MC/PC32A3X
FC/MC/PC35B3X
FC/MC/PC35C3X
FC/MC/PC/UC36A3X
FC/MC/PC/UC36B3X
FC/MC/PC/UC36C3X
FC/MC/PC37A3X
FC/MC/PC43B3X
FC/MC/PC43C3X
FC/MC/PC/UC48C3X
FC/MC/PC/UC48D3X
FC/MC/PC/UC60D3X
FC/MC62D3X
HC18A3X
HC30A3X
HC36B3X
HC42C3X
HC60D3X
AHP18B3X
AHP30B3X
AHP36C3X
AHP42C3X
Additional Charge, Oz
–
902 + 4
907 + 2
903 + 0
903 + 0
–
–
–
–
–
65 + 8
75 + 2
73 + 4
–
–
–
–
903 + 8
903 + 2
904 + 4
–
–
–
–
65 + 8
75 + 2
73 + 4
–
–
–
–
903 + 8
903 + 2
904 + 4
–
–
–
–
–
–
73 + 0
87 + 0
905 + 0
–
–
–
–
–
904 + 0
–
–
–
–
–
–
87 + 4
–
–
–
–
–
–
905 + 4
48 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
–
55 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
55 + 4
61 + 0
–
–
–
–
–
902 + 4
907 + 0
–
–
–
–
–
55 + 4
61 + 2
65 + 0
75 + 0
–
–
–
902 + 4
907 + 2
903 + 0
903 + 0
–
–
–
–
–
–
–
–
87 + 0
–
–
–
–
–
–
905 + 0
48 + 0
–
–
–
–
–
–
902 + 0
–
–
–
–
–
–
–
55 + 4
61 + 0
–
–
–
–
–
902 + 4
907 + 0
–
–
–
–
–
–
61 + 2
65 + 0
–
–
–
–
–
907 + 2
903 + 0
–
–
–
–
–
–
65 + 0
75 + 0
–
–
–
–
–
903 + 0
903 + 0
–
–
Johnson Controls Unitary Products
3
Preview Limit Reached! To view more of this manual,
please visit:
http://freemanualdownload.com/York-YCJD18-free-man
ual-download