HSEUreg10001 DIN Rail

Add to my manuals
5 Pages

advertisement

HSEUreg10001        DIN Rail | Manualzz
HSEUreg10001
DIN Rail
Made in Germany
1008W Programmable DC Power Supply
Short Specification:
•
•
•
•
•
•
•
•
•
•
Metal housing
90% efficiency
-25°C...+60°C full output power
Natural convection
Galvanic insulated
Continuous short circuit protected
Overload (OVP) & low voltage protected
Soft start & auto-recovery
Hold up time >30ms
No base load required
•
•
•
•
•
•
•
•
•
•
Analogue interface 0-10Vdc/0-20mA/4-20mA(option)
External shutdown
Sense control
Series & parallel operation
DIN Rail 35mm & wall mount
Screw terminals AWG20...AWG6
High reliability, shock & vibration proof
24 hours burn in test
EMI/EMS EN61000-6-2,3, EN55022 class B
IEC(EN)60950-1 in accordance to cUL60950/16950
Available outputs: 0…18V, 0…30V, 0…50V, 0...90V, 0...130V, 0...180V, 0...240V
In accordance with IEC60950-1
Camtec Systemelektronik GmbH – Gewerbestraße 30 – D-76327 Pfinztal – Germany
p.1/5 02.12G
Phone 0049(721)46596-0 - Fax 0049(721)46596-77 – www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
AC Input
AC Input Rating
Rated DC Voltage
90..132Vac / 184..265Vac , 47…63Hz , 250…375Vdc
115Vac<16.8A 230Vac<9.0A 250Vdc<5.0A 375Vdc<3.3A
0...15V
0...30V
0...50V
0...90V
0...130V
0...180V
0...240V
Overvoltage Protection
18Vdc
35Vdc
59Vdc
105Vdc
150Vdc
210Vdc
280Vdc
Rated DC Current
50A
33A
20A
11.2A
7.8A
5.6A
4.2A
Power Boost -25...+60°C <1min.
55A
36.3A
22A
12.3A
8.6A
6.1A
4.6A
Max. DC Current +70°C
37.5A
24.8A
15A
8.4A
5.9A
4.2A
3.2A
Ripple Peak 230Vac 20MHz
50mVpp
50mVpp
100mVpp
200mVpp
250mVpp
300mVpp
400mVpp
Sense function
Compensation 2V per lead load, protective electrical separation ≤60Vdc
Remote Shutdown
protective electrical separation ≤60Vdc
Analogue Interface
see table, 4-20mA available option, protective electrical separation ≤60Vdc, work.res.=500Ω
Pmax
1000W continuous
Derating
Accurancy
Latency Interface
Load regulation
Response Load Change
Base Load
Efficiency 230Vac
Short Circuit Protection
Idling-proof
Temperature Control
Hold Up Time
Inrush Current
Softstart
Cooling
Ambient Operating Temp.
Ambient Storage Temp.
Environment
EMI
EMS
Safety
Safety class 1(A)
Isolation Path
Input / Output
Meantime By Failure (MTBF)
Dimensions (HxWxD)
Weight
Screw Terminals (In/Out)
+60°C...+70°C 2.5%/ °C
< ± 1.5%
t.b.d.
< ± 0.2% 0-100%
<1ms 10-100%, 100-10%
None
90% typical
Continuous
Yes
Yes, thermal shutdown with auto recovery (+70°C, metering distance 10mm)
> 30ms 230Vac
< 162A (230Vac)
100ms typical
Controlled fan (manufacturer EBM-Papst)
- 25°C…+70°C
- 40°C…+85°C
Humidity 95% non-condensing @ 25°C, climate class . 3k3, pollution rate II
EN55022 class B
EN61000-6-2,3
cUL60950, EN60950-1
VDE0805, VDE0100
> 8mm
Galvanic insulated
400000h (IEC61709)
130x200x114,5mm
3000g
AWG20...AWG6 , 0.5...16mm² (76A @ 40°C)
Interface
Progamme [V]
Progamme [A]
Progamme [A]
Shutdown
Sensing
¹) option
0...10Vdc
0...20mA
4...20mA ¹)
external
2V lead load
Ordering Information:
Output
Type (DIN-Rail standard)
Part Number
Option
Part Number
0...18V
HSEUreg10001.18T
304.1053.001CA
220.1002.001CA
0...30V
HSEUreg10001.30T
304.1053.002CA
Backplate kit
(wallmount)
0...50V
HSEUreg10001.50T
304.1053.003CA
HSEUreg10001.90T
304.1053.004CA
ADTW201
DC-repeater
304.1090.001CA
0...90V
0...130V
HSEUreg10001.130T
304.1053.005CA
4..20mA option
0...180V
HSEUreg10001.180T
304.1053.006CA
Ad 420 to the type number example:
HSEUreg04801.15T420
0...240V
HSEUreg10001.240T
304.1053.007CA
Screw terminal plug
3520037 2pol. LS5,08 (package=10pcs)
Camtec Systemelektronik GmbH – Gewerbestraße 30 – D-76327 Pfinztal – Germany
p.2/5 02.12G
Phone 0049(721)46596-0 - Fax 0049(721)46596-77 – www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
P
I
D
C
O
N
T
R
O
L
C
O
N
V
E
R
T
E
R
C
T
F
I
L
T
E
R
1 = transient filter
2 = rectifier
3 = inrush limiter NTC
4 = load capacitor
5 = transformer
6 = storage throttle
1) Active Transient Filter
2) Rectifier
3) Inrush Current Limiter
4) Load Capacitor
5) Power Transformer
6) Storage Choke
Technical Description
The HSEUreg-Series is a programmable switch mode power supply. Engineered and manufactured in by CAMTEC in Germany, it is designed
for challenging applications like railway, drives, test-stands and machine-building. The HSEUreg provides a low Ripple-Noise, good LoadRegulation and high efficiency >90% (typ. @ 230Vac). High-end long life capacitors guarantee Hold-up-Time and extended lifetime of the
power supply. Our HSEUreg-design starts complex loads easily. The internal control manages illegal operating conditions to prevent your
system from failures. All HSEUreg power supplies are idling-proof and short circuit protected. Supply units of the same type and output
voltage feature parallel or series operation.
The HSEUreg also features active high input transients with suppressor diodes, X2-capacitors and varistors. The design rules set value on
extended interference immunity and safety. The PSU is engineered in accordance to EN60950-1 and EMC-compatibility to EN55022 class B.
Series Connection (fig.1)
Parallel Connection (fig.2)
Series Connection (fig.1)
To increase output voltage equal HSEUreg can be
connected in series. The control I/O should be galvanic
insulated in the series mode. If not the minus main output
is connected to the control I/O. Use our external option
Isolating Transformer ADTW201 being validated with the
HSEUreg. Be aware of safety norms if your target output
voltage exceeds safety voltage.
Parallel Connection (fig.2)
To increase the output power up to 3 HSEUreg can be
parallel connected. Advise using busbars to connect
HSEUreg in parallel. Always use identical length and
identical cross sections to the busbar.
ADTW201 Isolating Transformer (option)
The isolating transformer is used to galvanic isolate
impressed current. The device is self powered. The input
to output ratio is 1:1.
Technical Information ADTW201 external DC-Repeater
Input (Ie)
Voltage drop (Uw)
Max. apparent ohmic resistance (Ra)
Input Impedance (R)
Barrier Frequency (Fa)
Output
Ripple / Noise
Linear Failure
Transient oscillation current
Latency
Isolation Voltage Input/output
Operation Temperature
Temperature Drift
Weight
Ordering Information
0…20mA, 4…20mA (max. 50mA)
Uw>1.5V (Ie=20mA)
500R @ Ie=20mA
R=Ra+Uw/IE
Fa=5kHz (-3dB) with Ra=500R @ Ie=20mA
1:1
>0,5% with 20mA and Ra=500R
>0,03% / 100R
35uA
150us 0..20mA, Ra=500R, 10…90%
500V
0…50°C
Approx. 15ppm/K
21g
Part No: 304.1090.001CA
Camtec Systemelektronik GmbH – Gewerbestraße 30 – D-76327 Pfinztal – Germany
p.3/5 02.12G
Phone 0049(721)46596-0 - Fax 0049(721)46596-77 – www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Coating Option
We offer the USEUIreg-series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature
changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic
resin. It is procured with a robotics varnishing machine.
Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0
Ordering Information: ad extension C to the complete type number: HSEUreg10001.180TC or HSEUreg10001T420C
Test
Type Test
Factory Test
Field Test
a)
b)
c)
d)
Time
60s
5s
2s
A
2500Vac
2000Vac
2000Vac
B
3000Vac
2000Vac
2000Vac
C
500Vdc
500Vdc
500Vdc
D
500Vdc
500Vdc
500Vdc
Type test and factory tests are
conducted by the manufacturer.
Do not repeat the test in field.
Field test rules:
Use approriate test equipment which apply the voltage with a slow ramp
Connect L1 and N together, as well as all output poles
Use only AC test-voltages with 50/60Hz. The output voltages is floating and has
no ohmic reference to ground.
If testing output voltages are ≥60Vdc remain to security directives.
Use only isolated screw drivers to adjust output voltages.
Terminal Connects:
DC Mains Outputs
DC + voltage
DC + voltage
DC - voltage
DC - voltage
AC Main Input
GND common
N - wire
L - wire
Inputs/Outputs
Ureg
= programmable voltage input
Ureg
= programmable current input
SD
= shut down input
Sense
= Sensing (compensation: 2V)
Mechanics & Installation of the HSEUreg
Stable metal/aluminium housing IP20. To allow adequate convection, a free air space of 50mm (top/bottom) and 5mm (sidewalls) is
required; for active devices 15mm space from the sidewalls. For free air convection it is necessary to install the HSEUreg horizontal. You
can use the DIN-Rail installation (equiped standard) with our patented 35mm DIN-Rail bracket according to EN60275. It is easy to
mount/dismount while snaping it onto the 35mm DIN-Rail - any tools necessary. A wallmount backplate (option) is availble, too
Backplate Option
Camtec Systemelektronik GmbH – Gewerbestraße 30 – D-76327 Pfinztal – Germany
p.4/5 02.12G
Phone 0049(721)46596-0 - Fax 0049(721)46596-77 – www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Safety Instructions: Please read all warnings and advices carefully before installing or operating the HSEUreg. Retain this operation manual always
ready to hand.The HSEUreg must be installed by specialist staff only.
Installation:
1.)
2.)
3.)
4.)
The HSEUreg is designed for systems fulfilling the safety norms of
dangerous voltages/energy and fire prevention
Installation is restricted to specialists only, make sure that the AC
wire system is free of voltage
Opening the HSEUreg, making any modifications to it, dismounting
any screws from it, operating the HSEUreg out of specification
and/or using it in appropriate area will unevitably result in loosing
manufactureres guarantee; we decline taking any responsibility for
risk of demages caused to someones health or to any installed
system.
Attention: The HSEUreg has an internal input fuse. It is necessary to
wire an automatic circuit braker to the line. We suggest to use a
16A-type with B-characteristic. It is verboten to operate the
HSEUreg without protective earth wired. It essential to install a line
switch before the HSEUreg.
Warnings:
Disregard these warnings can cause fire, electic shock, serious
accident and death.
1.
2.
3.
4.
5.
6.
7.
Never operate the HSEUreg without Protective Earth
Conductor
Before connecting the HSEUreg to the AC wire system
make all wires free of voltage and assure accidently
switch on
Allow neat and professionel cabeling
Never open nor try to repair the HSEUreg by yourself.
Inside are dangerous voltages that can cause electric
shock hazard.
Avoid metal pieces or other conductive material to fall into
the HSEUreg
Do not operate the HSEUreg under damp or wet
conditions
It is verboten to operate the HSEUreg under Ex conditions
or in Ex-Area
All parameters base on 5 minutes run-in @ full load / 25°C / 230Vac 50/60Hz, as otherwise stated.
Camtec Systemelektronik GmbH – Gewerbestraße 30 – D-76327 Pfinztal – Germany
p.5/5 02.12G
Phone 0049(721)46596-0 - Fax 0049(721)46596-77 – www.camtec-gmbh.com - [email protected]
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement