General Manual

General Manual

FXM 11.20A.xx.xx0, FXM 11.30A.xx.xx0, FXM 11.40A.xx.xx0, FXM 12.20A.xx.xx0, FXM 12.30A.xx.xx0, FXM 12.40A.xx.xx0, FXM 13.20A.xx.xx0, FXM 13.30A.xx.xx0, FXM 13.40A.xx.xx0, FXM 14.20A.xx.xx0, FXM 14.30A.xx.xx0, FXM 14.40A.xx.xx0, FXM 31.20A.xx.xx0, FXM 31.30A.xx.xx0, FXM 31.40A.xx.xx0, FXM 32.20A.xx.xx0, FXM 32.30A.xx.xx0, FXM 32.40A.xx.xx0, FXM 33.20A.xx.xx0, FXM 33.30A.xx.xx0, FXM 33.40A.xx.xx0, FXM 34.20A.xx.xx0, FXM 34.30A.xx.xx0, FXM 34.40A.xx.xx0, FXM 53.12A.xx.xx0, FXM 53.20A.xx.xx0, FXM 53.30A.xx.xx0, FXM 53.40A.xx.xx0, FXM 54.12A.xx.xx0, FXM 54.20A.xx.xx0, FXM 54.30A.xx.xx0, FXM 54.40A.xx.xx0, FXM 55.12A.xx.xx0, FXM 55.20A.xx.xx0, FXM 55.30A.xx.xx0, FXM 55.40A.xx.xx0 are synchronous servo motors with permanent magnets ideal for control of feed and positioning axes on machines. These motors are suitable for use with Fagor servo drives and offer high positioning accuracy and reliability.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Fagor FXM Series Synchronous Motors General Manual | Manualzz

SERVO-DRIVESYSTEM

General Manual

Ver. 0002 (ing)

Title

Type of documentation

Internal code

Model

Version

Software

Electronic document

Servo-Drive System

Description, Installation and setup of motors and digital drives.

04754001

MAN REGUL (IN)

0002

Version 04.01

D_DDS.pdf

Headquarters FAGOR AUTOMATION S.COOP.

Bº San Andrés s/n, Apdo. 144

E-20500 ARRASATE-MONDRAGON www.fagorautomation.mcc.es

[email protected]

Service Dept. Telephone 34-943-771118

The information described in this manual may be subject to changes due to technical modifications.FAGOR AUTOMATION, S. Coop. reserves the right to change the contents of this manual without prior notice.

Evolution Version

9702

9707

9802

9810

9904

0002 items

First version

PS-65, RM-15, CM-60, APS24, AXD3.., y SPD3..

PowerPro 110A, new motors FXM.

Compact 8,25, 50,75, DDS PROGRAM MOD.

Software 02.xx:

Halt signal via digital input.

Range expansion, (C axis)

SERCOS interface. (connection and parameters)

Software 03.xx:

Sincoder feedback (E1). Motor identification at the encoder. Description of the

XPS. Emergency ramps. Current filter. Sercos interface (servo system adjustment). Expansion of parameters for gear ratios. Communications with the

PLC. Overload detection. Spindles at low rpm.

Software 03.03:

New fanned motors FXM.

New SPM 180M motor.

New products (Mains voltage 460 Vac).

Full motor identification.

Description and installation of the XPS.

New drive AXD/SPD 1.35.

EMK. filters.

Drive off delay time, GP9.

SPMxx.1 Motors Absolut encoder A1

Improved AXD/SPD 1.15.

Digital I/O boards.

Software 04.01:

PS-25B

Resistences ER.

Current filter.

Position Loop:

Feedforward, Homing, Backlash compensation,

Following error control, Modulo Format.

Direct feedback.

RELATED DOCUMENTATION

Fagor Motors and Drives

Ordering Handbook

Servo Drive System

Code: 04754001

This is your document.

Sistema de Regulación

Code: 04754000

Fagor Motion Control

Code: 04xxxxxx

Fagor Motion Control

Code: 04xxxxxx

Fagor Modular Drives and

Motors Quick Reference

Code: 14460010

Fagor Compact Drives and

Motors Quick Reference

Code: 14460012

General Index

pg.

SM.

SM.1

SM.2

SM.3

SM.4

SM.5

SM.5.1

SM.5.2

SM.5.2.1

SM.5.2.2

SM.6

SM.7

SM.8

SM.9

FXM SERIES SYNCHRONOUS MOTORS ........................................................... SM - 1

GENERAL CHARACTERISTICS .................................................................................... SM - 2

ELECTRICAL CHARACTERISTICS ................................................................................ SM - 3

DIMENSIONS .............................................................................................................. SM - 7

BRAKE CHARACTERISTICS ....................................................................................... SM - 12

CONNECTORS ........................................................................................................... SM - 12

POWER AND BRAKE CONNECTOR ......................................................................... SM - 12

FEEDBACK CONNECTOR ........................................................................................ SM - 13

ENCODER FEEDBACK CONNECTOR ..................................................................... SM - 13

RESOLVER FEEDBACK CONNECTOR .................................................................... SM - 14

INSTALLATION AND MOUNTING CONDITIONS ............................................................. SM - 15

RADIAL AND AXIAL LOADS ........................................................................................ SM - 15

IDENTIFICATION BOARD ............................................................................................ SM - 16

REGISTRATION NUMBERS FOR FXM MOTORS .......................................................... SM - 16

AM.

AM.1

AM.2

AM.3

AM.4

AM.5

AM.6

AM.7

AM.8

AM.8.1

AM.8.2

AM.8.3

AM.9

AM.9.1

AM.9.2

AM.9.3

AM.10

AM.10.1

AM.10.2

AM.10.3

AM.10.4

AM.10.5

AM.11

AM.12

AM.13

AM.13.1

AM.14

AM.15

SPM ASYNCHRONOUS MOTORS ........................................................................ AM - 1

GENERAL CHARACTERISTICS .................................................................................... AM - 1

ELECTRICAL CHARACTERISTICS ............................................................................... AM - 2

FAN CHARACTERISTICS ............................................................................................. AM - 3

BRAKE CHARACTERISTICS (OPTIONAL) ..................................................................... AM - 4

CHARACTERISTICS OF THE ROLLER BEARINGS ........................................................ AM - 4

POWER AND TORQUE CHARACTERISTICS ................................................................. AM - 5

DIMENSIONS ............................................................................................................. AM - 12

CONNECTORS ........................................................................................................... AM - 22

POWER AND BRAKE CONNECTION ......................................................................... AM - 22

FEEDBACK CONNECTION. ENCODER ..................................................................... AM - 23

FAN CONNECTION ................................................................................................... AM - 23

INSTALLING RECOMMENDATIONS ............................................................................. AM - 24

VENTILATION ........................................................................................................... AM - 25

MOUNTING OPTIONS ............................................................................................... AM - 25

AMBIENT CONDITIONS ............................................................................................ AM - 26

COUPLING ................................................................................................................. AM - 26

DIRECT COUPLING .................................................................................................. AM - 26

COUPLING THROUGH TRANSMISSION PULLEYS ..................................................... AM - 26

COUPLING THROUGH GEAR BOXES ....................................................................... AM - 27

BALANCING ............................................................................................................. AM - 27

MOUNTING THE GEAR BOXES ................................................................................. AM - 27

RADIAL AND AXIAL LOADS ........................................................................................ AM - 27

BEARINGS ................................................................................................................ AM - 28

MAINTENANCE INTERVALS ....................................................................................... AM - 29

BEARING REPLACEMENT ....................................................................................... AM - 29

IDENTIFICATION BOARD ............................................................................................ AM - 30

REGISTRATION NUMBERS FOR SPM MOTORS .......................................................... AM - 30

EM.

EM.1

EM.1.1

EM.1.2

EM.1.3

EM.1.3.1

EM.1.3.2

EM.1.3.3

EM.1.3.4

ELECTRONIC MODULES ...................................................................................... EM - 1

POWER SUPPLY MODULE ......................................................................................... EM - 5

GENERAL CHARACTERISTICS OF THE NON-REGENERATIVE POWER SUPPLIES ..... EM - 6

GENERAL CHARACTERISTICS OF THE REGENERATIVE POWER SUPPLIES ............. EM - 8

POWER SUPPLY CONNECTORS .............................................................................. EM - 9

POWER CONNECTORS OF THE POWER SUPPLIES .............................................. EM - 11

X1 CONNECTOR, INTERNAL BUS ........................................................................... EM - 14

X2 CONNECTOR, CONTROL ................................................................................... EM - 14

CONNECTORS X3, X4, X5, X6 (XPS AND PS-25B) ..................................................... EM - 16

EM.2 MODULAR DRIVE (AXES AND SPINDLE) ................................................................... EM - 17

EM.2.1 GENERAL CHARACTERISTICS, MODULAR DRIVES .................................................. EM - 17

EM.2.1.1 AXIS AND SPINDLE DRIVES ................................................................................... EM - 17

EM.2.2 DERATING OF THE MODULAR DRIVES ..................................................................... EM - 18

EM.2.3 CONNECTORS OF THE MODULAR DRIVE ................................................................ EM - 20

EM.2.3.1 POWER CONNECTORS ......................................................................................... EM - 21

EM.3 COMPACT DRIVE (AXES AND SPINDLE) ..................................................................... EM - 22

EM.3.1 GENERAL CHARACTERISTICS ................................................................................ EM - 22

EM.3.2 DERATING, COMPACT DRIVES ................................................................................. EM - 22

EM.3.3 CONNECTORS OF THE COMPACT DRIVE ................................................................. EM - 24

EM.3.3.1 POWER CONNECTORS ......................................................................................... EM - 25

EM.3.3.2 CONNECTOR X1 ..................................................................................................... EM - 27

EM.4 ASPECTS COMMON TO BOTH MODULAR AND COMPACT ......................................... EM - 28

EM.4.1 STATUS DISPLAY ..................................................................................................... EM - 28

EM.4.2 SERCOS CONNECTION ............................................................................................ EM - 29

EM.4.3 CONNECTOR X2, CONTROL ..................................................................................... EM - 30

EM.4.3.1 SPEED ENABLE, DRIVE ENABLE ......................................................................... EM - 32

EM.4.4 CONNECTOR X3 ....................................................................................................... EM - 34

EM.4.4.1 X3, ENCODER SIMULATOR ..................................................................................... EM - 34

EM.4.4.2 X3, DIRECT FEEDBACK .......................................................................................... EM - 35

EM.4.5 CONNECTOR X4, FEEDBACK ................................................................................... EM - 36

EM.4.6 CONNECTOR X5, SERIAL LINE ................................................................................. EM - 37

EM.4.7 CONNECTORS AT SL1 AND SL2 ............................................................................... EM - 38

EM.4.7.1 A1 CARD ........................................................................................................... EM - 38

EM.4.7.2 CARDS 8DI-16DO AND 16DI-8DO ...................................................................... EM - 42

EM.4.7.3 NUMBERING OF THE PLC RESOURCES ON THE CARDS .................................. EM - 44

EM.4.8 INTERNAL CONFIGURATION ..................................................................................... EM - 45

EM.5 MAINS FILTER, EMK .................................................................................................. EM - 46

EM.6 CHOKE FOR AN "XPS" POWER SUPPLY ................................................................... EM - 47

EM.7 RESISTOR MODULES: RM-15, ER. ............................................................................ EM - 48

EM.8 CAPACITOR MODULE, CM-60 ..................................................................................... EM - 50

EM.9 AUXILIARY POWER SUPPLY MODULE, APS 24 .......................................................... EM - 50

EM.9.1 APS 24 CONNECTORS ............................................................................................. EM - 51

EM.10 PROGRAMMING MODULE, DDS PROG MODULE ....................................................... EM - 52

EM.11 FAGOR CABLES ........................................................................................................ EM - 53

EM.12 DIMENSIONS ............................................................................................................. EM - 54

EM.13 MODULE IDENTIFICATION. ......................................................................................... EM - 57

IN. INSTALLATION ........................................................................................................... IN - 1

IN.1 SECURING ALL THE ELEMENTS ................................................................................... IN - 2

IN.1.1 PLACEMENT OF THE SERVO DRIVE SYSTEM ............................................................ IN - 2

IN.2 INTER-MODULAR CONNECTION .................................................................................... IN - 4

IN.2.1 POWER BUS CONNECTION ........................................................................................ IN - 4

IN.2.2 GROUND CONNECTION .............................................................................................. IN - 5

IN.2.3 INTERNAL BUS CONNECTION ..................................................................................... IN - 5

IN.2.4 CONNECTION TO THE EXTERNAL BALLAST RESISTOR ............................................... IN - 6

IN.3 POWER LINE CONNECTION .......................................................................................... IN - 8

IN.3.1 CABLING OF THE SYSTEM TO MAINS ......................................................................... IN - 8

IN.3.1.1 MAINS FILTER, EMK. ................................................................................................ IN - 8

IN.3.1.2 FUSES. .................................................................................................................... IN - 9

IN.3.1.3 TRANSFORMER OR AUTOTRANSFORMER. ............................................................. IN - 10

IN.3.1.4 LINE INDUCTANCE ................................................................................................... IN - 10

IN.3.1.5 SECTION OF THE CABLES FOR MAINS CONNECTION. ............................................. IN - 11

IN.3.1.6 MECHANICAL CHARACTERISTICS OF THE CONNECTORS ....................................... IN - 12

IN.3.2 MOTOR/DRIVE CONNECTION ..................................................................................... IN - 13

IN.3.2.1 GUIDE FOR SELECTING THE POWER CABLES OF THE MOTORS ............................ IN - 14

IN.3.3 GROUND CONNECTION ............................................................................................. IN - 17

IN.4 CONNECTING THE MOTOR FEEDBACK TO THE DRIVER .............................................. IN - 18

IN.4.1 EEC ENCODER CONNECTION .................................................................................... IN - 18

I N.4.2

IN.5

IN.6

IN.7

IN.7.1

IN.7.2

IN.7.3

IN.7.4

IN.7.4

IN.7.5

IN.8

IN.9

REC RESOLVER CONNECTION .................................................................................. IN - 18

BRAKE CONTROL ........................................................................................................ IN - 19

CONTROL POWER SUPPLY FOR THE MODULES ......................................................... IN - 20

CONTROL AND COMMUNICATION SIGNALS ................................................................. IN - 22

ENCODER SIMULATION CONNECTION, SEC .............................................................. IN - 22

DIRECT FEEDBACK CONNECTION ............................................................................. IN - 22

ANALOG VELOCITY COMMAND ................................................................................. IN - 23

DIGITAL OUTPUTS ..................................................................................................... IN - 23

SERCOS CONNECTION ............................................................................................. IN - 24

SERIAL LINE CONNECTION ........................................................................................ IN - 25

CONNECTIONS ............................................................................................................ IN - 27

ELECTRICAL CABINET DRAWINGS .............................................................................. IN - 30

GSU.

GSU.1

GSU.2

GSU.3

GSU.4

GSU.5

GSU.6

GSU.7

GSU.8

GSU.9

GSU.10

GSU.11

GSU.12

COMMON SETUP ....................................................................................................SU - 1

MODULE POWER-UP .................................................................................................. SU - 1

DATA STORAGE STRUCTURE ...................................................................................... SU - 2

WINDDSSETUP ........................................................................................................... SU - 3

ACCESS LEVELS ........................................................................................................ SU - 4

PARAMETER EDITING ................................................................................................. SU - 5

SAVE INTO FLASH MEMORY ....................................................................................... SU - 6

INITIALIZATION PROCESS ............................................................................................ SU - 7

TRANSFERRING PARAMETER TABLES ........................................................................ SU - 8

MOTOR IDENTIFICATION .............................................................................................. SU - 9

POSITION OR VELOCITY DRIVE ................................................................................. SU - 13

ADJUSTMENT OF THE ENCODER OFFSET ................................................................ SU - 15

CURRENT FILTER ADJUSTMENT ................................................................................ SU - 16

SSU.

SSU.1

SSU.2

SSU.3

SSU.3.1

SSU.3.2

SSU.3.3

SSU.3.4

SSU.4

SSU.5

SSU.5.1

SSU.5.2

SSU.5.3

SSU.5.3.1

SSU.5.3.2

SSU.5.3.3

SSU.5.4

VELOCITY DRIVE SETUP .......................................................................................SU - 1

ADJUSTMENT OF THE OFFSET OF THE ANALOG SIGNAL ........................................... SU - 1

VOLTS-SPEED OF THE ANALOG VOLTAGE ................................................................. SU - 2

PARAMETERS FOR THE ENCODER SIMULATOR .......................................................... SU - 3

NUMBER OF PULSES ................................................................................................ SU - 3

MARKER PULSE (HOME I0 ) POSITION ...................................................................... SU - 3

COUNTING DIRECTION ............................................................................................... SU - 4

PIN-OUT OF THE ENCODER SIMULATOR CONNECTOR .............................................. SU - 4

ANALOG OUTPUTS ...................................................................................................... SU - 5

VELOCITY LOOP SETTING ........................................................................................... SU - 7

VELOCITY COMMAND GENERATOR .......................................................................... SU - 7

SPEED-PI ADJUSTMENT ........................................................................................... SU - 8

VELOCITY COMMAND FILTERS ................................................................................ SU - 11

EMERGENCY ACCELERATION LIMIT ...................................................................... SU - 12

RAMP GENERATION .............................................................................................. SU - 12

JERK LIMIT ............................................................................................................ SU - 13

REMOVAL OF THE INTERNAL COMMAND ............................................................... SU - 14

PSU.

PSU.1

PSU.2

PSU.3

PSU.4

PSU.5

PSU.5.1

PSU.5.2

PSU.5.3

PSU.6

PSU.7

PSU.8

PSU.9

POSITION DRIVE SETUP ........................................................................................SU - 1

POSITION LOOP .......................................................................................................... SU - 1

DIRECT FEEDBACK ..................................................................................................... SU - 3

PROPORTIONAL CONTROL .......................................................................................... SU - 4

VELOCITY FEEDFORWARD ......................................................................................... SU - 5

HOME SEARCH ........................................................................................................... SU - 6

INCREMENTAL FEEDBACK ........................................................................................ SU - 6

LINEAR FEEDBACK WITH DISTANCE-CODED REFERENCE MARKS ......................... SU - 10

ABSOLUTE FEEDBACK ........................................................................................... SU - 12

BALLSCREW BACKLASH COMPENSATION ................................................................ SU - 12

FOLLOWING ERROR MONITORING ............................................................................ SU - 13

MODULE FORMAT ..................................................................................................... SU - 14

STARTUP SUMMARY ................................................................................................. SU - 15

AP.

AP.3.2

AP.3.2.1

AP.3.2.2

AP.3.2.3

AP.3.3

AP.4

AP.4.1

AP.4.2

AP.4.3

AP.5

AP.6

AP.7

AP.8

AP.9

AP.1

AP.1.1

AP.1.1.1

AP.1.1.1.1

AP.1.1.1.2

AP.1.1.2

AP.1.1.2.1

AP.1.1.2.2

AP.1.1.2.3

AP.1.2

AP.1.3

AP.2

AP.3

AP.3.1

AP.3.1.1

AP.3.1.2

APPLICATIONS ......................................................................................................... AP - 1

SERCOS CONNECTION WITH THE 8050/55 CNC ........................................................... AP - 1

CONSIDERATIONS AT THE 8050/55 CNC ..................................................................... AP - 2

IDENTIFICATION AND OPERATION MODE ................................................................. AP - 2

8050/55 IN "0" MODE (EXTERNAL FEEDBACK) .................................................... AP - 3

8050/55 CNC IN "1" MODE (MOTOR'S OWN FEEDBACK) ..................................... AP - 3

OTHER 8050/55 CNC PARAMETERS ......................................................................... AP - 4

ON AXIS DRIVES ................................................................................................. AP - 5

ON SPINDLE DRIVES IN OPEN LOOP. ................................................................. AP - 6

ON SPINDLE DRIVES IN CLOSED LOOP, M19 OR RIGID TAPPING. ....................... AP - 7

CONSIDERATIONS AT THE DRIVES .......................................................................... AP - 10

CONTROL SIGNALS PLC8050/55 - DRIVE .................................................................. AP - 11

CONNECTION WITH THE FAGOR 8070 CNC ................................................................ AP - 14

PARAMETER SET AND GEAR RATIOS ....................................................................... AP - 15

PARAMETER SET .................................................................................................... AP - 17

SET CHANGE THROUGH DIGITAL INPUTS .............................................................. AP - 17

SET CHANGE THROUGH SERCOS INTERFACE ...................................................... AP - 19

GEAR RATIOS .......................................................................................................... AP - 20

CHANGE OF GEAR RATIO THROUGH SERCOS INTERFACE .................................. AP - 21

EXAMPLE OF A PLC PROGRAM FOR A GEAR CHANGE AT THE MAIN SPINDLE ..... AP - 22

EXAMPLE OF A PLC PROGRAM FOR A PARAMETER SET CHANGE ...................... AP - 25

SETS AND GEAR RATIOS AT THE DDSSETUP MONITOR .......................................... AP - 28

VARIABLE MONITORING ............................................................................................ AP - 29

PROGRAMMING MODULE AS MONITOR .................................................................. AP - 29

DIGITAL ELECTRICAL SIGNALS FOR PLC OR MANOEUVER ..................................... AP - 30

ANALOG OUTPUTS FOR THE "DIAL" ........................................................................ AP - 31

HANDLING OF INTERNAL VARIABLES VIA SERCOS ................................................... AP - 32

SPINDLE MOTORS AT LOW RPM ............................................................................... AP - 34

HALT FUNCTION ........................................................................................................ AP - 35

MOTOR STOP DUE TO TORQUE OVERLOAD ............................................................. AP - 36

FLUX REDUCTION WITHOUT LOAD ............................................................................. AP - 37

DS.

DS.1

DS.1.1

DS.1.2

DS.1.3

DS.1.4

DS.2

DS.2.1

DS.2.1.1

DS.2.1.2

DS.2.2

DS.2.3

DS.2.4

DS.3

DS.4

DS.5

DESIGN ......................................................................................................................DS - 1

AXIS MOTOR AND SERVO DRIVE SELECTION ............................................................. DS - 1

FIRST MOTOR PRE-SELECTION ................................................................................. DS - 1

SECOND MOTOR PRE-SELECTION ........................................................................... DS - 3

THIRD MOTOR PRE-SELECTION ................................................................................. DS - 4

DRIVE SELECTION ..................................................................................................... DS - 5

SPINDLE MOTOR AND SERVO DRIVE .......................................................................... DS - 6

POWER DEMANDED FROM A MOTOR FOR A PARTICULAR LOAD ............................. DS - 6

POWER REQUIRED BY THE LOAD ........................................................................... DS - 7

POWER NEEDED FOR THE ACC / DEC OF THE SPINDLE MOTOR ............................ DS - 9

CALCULATION OF ACCELERATION AND BRAKING TIME ........................................... DS - 11

CALCULATION OF POWER WITH INTERMITTENT LOAD ............................................ DS - 11

DRIVE SELECTION ................................................................................................... DS - 11

POWER SUPPLY SELECTION .................................................................................... DS - 12

CM-60 SELECTION GUIDE .......................................................................................... DS - 16

BALLAST RESISTOR SELECTION GUIDE .................................................................... DS - 16

APPENDIX:

PARAMETERS, VARIABLES & COMMANDS ....................................................... APPENDIX A

LIST OF ERRORS, WARNINGS AND TROUBLESHOOTING .................................. APPENDIX B

FAGOR PRODUCTS REFERENCES .................................................................... APPENDIX C

COMPATIBILITY .................................................................................................. APPENDIX D

PROTECTIONS ON DRIVES AND MOTORS ......................................................... APPENDIX E

DECLARATION OF CONFORMITY

Manufacturer:

Fagor Automation, S. Coop.

Barrio de San Andrés s/n, C.P. 20500, Mondragón -Guipúzcoa- (SPAIN)

We hereby declare, under our responsibility that the product:

FAGOR Servo Drive System

Consisting of the following modules and accessories:

Power Supplies: XPS-25, XPS-65, PS-25A, PS-25B, PS-65A y APS 24

Modular Drives: AXD/SPD 1.08, 1.15, 1.25, 1.35, 2.50, 2.75, 3.100, 3.150

Compact Drives: ACD/SCD 1.08, 1.15, 1.25, 2.50, 2.75

Accessory Modules: RM-15, ER, CM-60, CHOKES y DDS PROG MODULE

Power Supply Filter: EMK 3040, EMK 3120

Motors: Brushless AC Fagor FMX, AXM and Spindle Asynchronous Fagor SPM mentioned on this declaration, with the basic requirements of the European Directives 73/23/CE on Low Voltage

(Basic Safety Regulation, Machinery Electrical Equipment EN60204-1:95) and 89/

336/CE on Electromagnetic Compatibility (EN 61800-3:1996, Specific Regulation on Electromagnetic Compatibility for Servo Drive Systems).

In Mondragon, February 15, 2000

WARRANTY TERMS

INITIAL WARRANTY

All products manufactured or marketed by FAGOR carry a 12-month warranty for the end user.

In order to prevent the possibility of having the time period from the time a product leaves our warehouse until the end user actually receives it run against this 12-month warranty, the OEM or distributor must communicate to FAGOR the destination, identification and installation date of the machine by filling out the Warranty Form that comes with each product.

The starting date of the warranty for the user will be the one appearing as the installation date of the machine on the Warranty Form.

This system ensures the 12-month warranty period for the user.

FAGOR offers a 12-month period for the OEM or distributor for selling and installing the product. This means that the warranty starting date may be up to one year after the product has left our warehouse so long as the warranty control sheet has been sent back to us. This translates into the extension of warranty period to two years since the product left our warehouse. If this sheet has not been sent to us, the warranty period ends

15 months from when the product left our warehouse.

FAGOR is committed to repairing or replacing its products from the time when the first such product was launched up to 8 years after such product has disappeared from the product catalog.

It is entirely up to FAGOR to determine whether a repair is to be considered under warranty.

EXCLUDING CLAUSES

The repair will take place at our facilities. Therefore, all shipping expenses as well as travelling expenses incurred by technical personnel are NOT under warranty even when the unit is under warranty.

This warranty will be applied so long as the equipment has been installed according to the instructions, it has not been mistreated or damaged by accident or negligence and has been handled by personnel authorized by FAGOR.

If once the service call or repair has been completed, the cause of the failure is not to be blamed the

FAGOR product, the customer must cover all generated expenses according to current fees.

No other implicit or explicit warranty is covered and FAGOR AUTOMATION shall not be held responsible, under any circumstances, of the damage which could be originated.

SERVICE CONTRACTS

Service and Maintenance Contracts are available for the customer within the warranty period as well as outside of it.

SM. FXM SERIES SYNCHRONOUS MOTORS

FXM series Fagor synchronous servo motors are AC Brushless, with permanent magnets.

These motors are designed to work with Fagor servo drives.

They are ideal to control feed and positioning axes in machine-tool applications as well as on material handling applications, textile machinery, printing, robotics, etc. and in any application requiring great positioning accuracy.

These motors have been manufactured in accordance with the European regulations

EN 60204-1 and EN 60034 as instructed by the European directive 89/392/CE on machine safety.

The major advantages of this type of motor are its smooth torque output, a high torque density, has no brushes, high reliability and low maintenance. These are essential in many applications like feeders, punch presses, etc.

Its main disadvantage is cost associated with the permanent magnets.

Only the stator of these three-phase servomotors heat up and, therefore, this heat can be easily dissipated via the armature. With this, if the customer so demands, they can reach a protection level of IP65, thus being immune to liquids and dirt. Its normal protection level is

IP64.

The system incorporates a temperature sensor for monitoring the internal temperature. They also carry a feedback encoder or resolver and can have an optional electromechanical brake.

The fan-cooled option of this motor range means a 50% increase in their features.

Synchronous Motors Ver. 0002 SM - 1

SM.1

GENERAL CHARACTERISTICS

Standard characteristics of FXM motors:

Excitation

Temperature sensor

Shaft end

Mounting

Mounting method

Mechanical tolerances

Balancing

Roller bearings' life

Noise

Vibration resistance

Electrical Insulation

Isolating resistance

Dielectric Strength

Degree of Protection

Storage temperature

Permited ambient temperature

Permited ambient humidity

Fan

Brake

Feedback

Permanent rare earth magnets (SmCo)

Thermistor

Cylindrical with keyway. (Option: with no keyway)

Face flange

B5-V1-V3 (as recommended by IEC-34-3-72)

Normal class (IEC-72/1971)

Class N (Class R optional) (DIN 45665)

(balanced with the whole key)

20,000 hours

DIN 45635

Withstands 1G along the shaft and 3G sideways (G = 10 m/s² ).

Class F (155°C) (311°F)

500 Vdc, 10 MOhms or greater

1500 Vac, one minute

Overall: IP64 standard, IP54 with fan

Axis: IP64 standard, IP65 with oil seal

From -20°C to +80°C (-4°F / 176°F)

From 0°C to +40°C (32°F / 74°F)

From 20% to 80% (non condensing)

Optional on models: FXM5 and FXM7.

Supply voltage: 220 Vac - 50/60 Hz

Consumption: 40 W - 0.25 Amp

Optional on all models.

See section on "Brake characteristics"

Sine-wave Encoder or Resolver

The F class isolation on the motor maintain the dielectric properties as long as the work temperature stays below 155°C (311°F).

SM - 2 Synchronous Motors

Ver. 0002

SM.2

ELECTRICAL CHARACTERISTICS

Torque/speed characteristic of synchronous motors:

Par -Nm-

Mp -Par de pico

del motor-

-Par de pico limitado

por el Regulador-

Mo -Par a rotor parado-

2

Límite de desmagnetización

Limitación por tensión

Limitación debida a la máxima corriente ofrecida por el Regulador.

1

Mn -Par nominal-

Velocidad -rpm-

nN

-Velocidad nominal-

1 Work area for permanent duty cycle (S1). Limited by the motor stall torque and the torque at rated speed.

2 Work area for intermittent duty cycle. The maximum torque to be provided by the motor is limited by the magnetic properties of the rotor and the maximum winding voltage.

The following pages show the characteristics tables for each FXM motor.

The drive recommended to govern each motor will provide the rated current necessary for the motor to give its rated torque and it will limit its peak current to keep the motor inside the intermittent duty cycle area.

Synchronous Motors Ver. 0002 SM - 3

NON-VENTILATED

MOTORS

FXM11.20A.xx.xx0

FXM11.30A.xx.xx0

FXM11.40A.xx.xx0

FXM12.20A.xx.xx0

FXM12.30A.xx.xx0

FXM12.40A.xx.xx0

FXM13.20A.xx.xx0

FXM13.30A.xx.xx0

FXM13.40A.xx.xx0

FXM14.20A.xx.xx0

FXM14.30A.xx.xx0

FXM14.40A.xx.xx0

FXM31.20A.xx.xx0

FXM31.30A.xx.xx0

FXM31.40A.xx.xx0

FXM32.20A.xx.xx0

FXM32.30A.xx.xx0

FXM32.40A.xx.xx0

FXM33.20A.xx.xx0

FXM33.30A.xx.xx0

FXM33.40A.xx.xx0

FXM34.20A.xx.xx0

FXM34.30A.xx.xx0

FXM34.40A.xx.xx0

FXM53.12A.xx.xx0

FXM53.20A.xx.xx0

FXM53.30A.xx.xx0

FXM53.40A.xx.xx0

FXM54.12A.xx.xx0

FXM54.20A.xx.xx0

FXM54.30A.xx.xx0

FXM54.40A.xx.xx0

FXM55.12A.xx.xx0

FXM55.20A.xx.xx0

FXM55.30A.xx.xx0

FXM55.40A.xx.xx0

Peak Torque (Nm) for 0.5 seconds.

Mo Mp n

N

-Nm-Nm-rpm-

Io Imax Pow

-A-A-kW-

KT

Nm/A tac

-ms-

L R J

-mHr- Ohms Kg.cm2

P

-Kg-

1.08

-Nm-

1.15

-Nm-

1.25

-Nm-

1.35

-Nm-

2.50

-Nm-

2.75

-Nm-

3.100

-Nm-

3,150

-Nm-

0,65

0,65

0,65

1,3

1,3

1,3

1,9

3,3

3,3

2000

3000

3,3 4000

6,5 2000

6,5 3000

6,5 4000

9,5 2000

1,9

1,9

9,5 3000

9,5 4000

2,6 13,0 2000

2,6 13,0 3000

0,3

0,4

0,5

0,5

0,8

1,0

0,8

1,1

1,5

1,0

1,6

2,6 13,0 4000

2,0 10,0 2000

2,0 10,0 3000

2,0 10,0 4000

3,9 19,5 2000

3,9 19,5 3000

3,9 19,5 4000

5,8 29,0 2000

5,8 29,0 3000

5,8 29,0 4000

7,9 39,5 2000

7,9 39,5 3000

2,0 10,0

0,8

1,1

1,5

1,5

2,3

3,1

2,3

4,0

5,5

7,5

7,5

11,5

15,5

11,5

3,5 17,5

4,6 23,0

3,1 15,5

4,7 23,5

7,9 39,5 4000

10,0 50,0 1200

10,0 50,0 2000

10,0 50,0 3000

10,0 50,0 4000

13,6 68,0 1200

13,6 68,0 2000

6,2 31,0

2,4 12,0

4,0 20,0

6,0 30,0

8,0 40,0

3,2 16,0

5,5 27,5

13,6 68,0 3000 8,1 40,5

13,6 68,0 4000 10,2 51,0

17,0 85,0 1200

17,0 85,0 2000

4,0

6,8

20,0

34,0

17,0 85,0 3000 10,2 51,0

17,0 85,0 4000 13,3 66,5

1,3

2,0

2,5

2,5

4,0

5,0

4,0

5,5

7,5

5,0

8,0

1,2

1,6

1,2

1,8

2,4

1,7

2,5

1,1

0,4

0,6

0,8

0,8

4,3

5,7

2,1

3,6

5,3

7,1

3,3

1,3

2,1

3,1

4,2

1,7

2,8

0,1

0,2

0,3

0,3

0,4

0,5

0,4

0,6

0,8

0,5

0,8

2,6 11,6 213,0 104,0

1,6 17,4 115,0 56,0

1,3 23,2 67,0 32,7

2,6 9,3 134,0 43,4

1,6 14,0 83,0 27,0

1,3 18,7 54,0 17,7

2,4 10,8 125,0 33,6

1,7 16,2 56,0 15,0

1,3 21,6 31,0 8,4

2,6 9,7 75,0 18,0

1,6 14,5 42,0 10,0

1,3 19,3 25,0

2,5 9,4 133,0

6,0

37,0

1,8 14,1 59,0 16,4

1,3 18,8 43,0 11,9

2,6 7,9 85,0 15,7

1,7 11,9 35,0

1,3 15,9 22,0

2,5 7,6 53,0

1,7 11,4 29,0

1,3 15,2 16,0

2,5 7,4 44,0

1,7 11,1 22,0

1,3 14,8 13,0

4,2 5,8 88,0

1,8

10,7

2,5 9,6 34,0 4,2

1,7 14,4 16,0

1,3 19,3 9,0

4,3 6,8 65,0

2,5 11,4 26,0

1,9

1,1

7,0

2,8

1,7 17,1 12,0

1,3 22,8 6,5

4,3 6,6 51,0

2,5 11,1 20,0

1,7 16,6 9,0

1,3 22,2 5,0

1,3

0,7

5,0

2,0

0,9

0,5

6,5

4,0

8,1

4,5

2,5

6,0

3,0

1,8

1,8

1,8

2,9

2,9

2,9

4,9

4,9

4,9

6,0

6,0

3,3

3,3

3,3

4,3

4,3

4,3

6,5

6,5

6,4

6,4

6,4

9,5

9,5

9,5

7,6 13,0

3,3

3,3

3,3

6,5

7,6 13,0

7,6 10,4 13,0

5,5 10,0

5,5 10,0

5,5 10,0

7,5 19,5

6,0

4,5

4,5

4,5

7,4

7,4

7,4

7,5 13,6 19,5

7,5 10,1 18,9 19,5

10,5

10,5

10,5

9,6 20,2 29,0

9,6

9,6

13,3 24,9 29,0

18,9 29,0

14,0 11,5 20,4 38,2 39,5

14,0 11,5 25,2 39,5

14,0 11,5 19,1 31,9 39,5

23,0 15,8 33,3 50,0

23,0 15,8 20,0 37,5 50,0

23,0 15,8 25,0 41,7 50,0

23,0 15,8 31,3 43,8 50,0

37,0 17,8 34,0 63,8 68,0

37,0 17,8 37,1 61,8 68,0

37,0 17,8

37,0 17,8

45,0 20,0

42,0 58,8 68,0

33,3 46,7 66,7 68,0

45,0 20,0 34,0 63,8 85,0

45,0 20,0 37,5 62,5 85,0

45,0 20,0 41,7 58,3 83,3 85,0

44,7 63,9 85,0

In bold, the combinations where the drive automatically limits its peak current to avoid damaging the motor.

Peak Torque (Nm) for 0.5 seconds.

NON-VENTILATED

MOTORS

FXM73.12A.xx.xx0

FXM73.20A.xx.xx0

FXM73.30A.xx.xx0

FXM73.40A.xx.xx0

FXM74.12A.xx.xx0

FXM74.20A.xx.xx0

FXM74.30A.xx.xx0

FXM74.40A.xx.xx0

FXM75.12A.xx.xx0

FXM75.20A.xx.xx0

FXM75.30A.xx.xx0

FXM75.40A.xx.xx0

*

FXM76.12A.xx.xx0

FXM76.20A.xx.xx0

FXM76.30A.xx.xx0

FXM76.40A.xx.xx0

*

FXM77.12A.xx.xx0

FXM77.20A.xx.xx0

FXM77.30A.xx.xx0

*

FXM77.40A.xx.xx0

*

FXM78.12A.xx.xx0

FXM78.20A.xx.xx0

FXM78.30A.xx.xx0

*

FXM78.40A.xx.xx0

*

(*)

Mo

19,5

Mp n

N

-Nm-Nm-rpm-

97,5 1200

19,5 97,5 2000

Io

-A-

Imax

-A-kWNm/A -ms-mHr- Ohms Kg.cm2

-Kg-Nm-Nm-Nm-Nm-Nm-Nm-Nm-Nm-

4,7 23,5

7,8 39,0

19,5 97,5 3000 11,3 56,5

19,5 97,5 4000 15,4 77,0

26,0 130,0 1200 6,2 31,0

Pow

2,5

4,1

6,1

8,2

3,3

KT

4,1

2,5

1,7

1,3

4,2 tac

11,9

19,8

29,6

39,5

11,6

L

58,0

22,0

10,0

6,0

44,0

R

4,8

1,8

0,8

0,5

3,1

J

92,0

92,0

92,0

92,0

120,0

P 1.08

1.15

1.25

1.35

2.50

2.75

3.100

3,150

29,0

29,0

29,0

29,0

31,6

62,2

62,9

97,5

62,5

43,1

104,8

87,5

60,4

44,3

130,0

97,5

86,3

63,3

97,5

95,0 97,5

26,0 130,0 2000 10,4 52,0

26,0 130,0 3000 15,4 77,0

5,4

8,2

26,0 130,0 4000 20,6 103,0 10,9

32,0 160,0 1200 7,7 38,5 4,0

32,0 160,0 2000 12,9 64,5 6,7

32,0 160,0 3000 19,3 96,5 10,1

32,0 160,0 4000 25,3 126,5 13,4

39,0 195,0 1200 9,3 46,5 4,9

39,0 195,0 2000 15,4 77,0 8,2

39,0 195,0 3000 22,6 113,0 12,3

39,0 195,0 4000 31,0 155,0 16,3

45,0 225,0 1200 10,9 54,5 5,7

45,0 225,0 2000 17,3 86,5 9,4

45,0 225,0 3000 26,5 132,5 14,1

45,0 225,0 4000 35,7 178,5 18,8

52,0 260,0 1200 12,5 62,5 6,5

52,0 260,0 2000 20,6 103,0 10,9

52,0 260,0 3000 31,0 155,0 16,3

52,0 260,0 4000 41,2 206,0 21,8

2,5 19,3 16,0

1,7 29,0 8,0

1,3 38,6 4,0

4,2 12,6 34,0

2,5 20,9 13,0

1,7 31,4 6,0

1,3 41,9 3,0

4,2 12,2 29,0

2,5 20,3 12,0

1,7 30,4 5,0

1,3 40,6 3,0

4,1 13,0 25,0

2,6 21,6 10,0

1,7 32,4

1,3 43,2

4,0

3,0

4,2 13,0 23,0

2,5 21,7

1,7 32,6

1,3 43,5

8,0

4,0

2,0

1,2 120,0 31,6

0,6 120,0 31,6

0,3 120,0 31,6

2,2 160,0 36,0

0,8 160,0 36,0

0,4 160,0 36,0

0,2 160,0 36,0

1,8 189,0 40,0

0,7 189,0 40,0

0,3 189,0 40,0

0,2 189,0 40,0

1,5 232,0 43,0

0,6 232,0 43,0

0,3 232,0 43,0

0,1 232,0 43,0

1,3 270,0 47,0

0,4 270,0 47,0

0,2 270,0 47,0

0,1 270,0 47,0

62,5 87,5 125,0 130,0

59,1 84,4 126,6 130,0

63,1 94,7 126,2 130,0

103,9 145,5 160,0

86,8 124,0 160,0

82,9 124,4 160,0

94,9 126,5 160,0

104,8 146,8 195,0

88,6 126,6 189,9 195,0

86,3 129,4 172,6 195,0

94,4 125,8 188,7

103,2 144,5 206,4 225,0

91,0 130,1 195,1 225,0

127,4 169,8 225,0

94,5 126,1 189,1

104,0 145,6 208,0 260,0

126,2 189,3 252,4 260,0

125,8 167,7 251,6

126,2 189,3

Motors with a power "base" which need to be connected via MC 46 type socket. All the others with MC 23.

In bold, the combinations where the drive automatically limits its peak current to avoid damaging the motor.

Mo, Io: Stall torque, with Io current permitted without time limit

Mp, Imax: Peak torque and maximum current

Very important: Imax must never be exceeded, because it would demagnetize the rotor.

n

N:

Pow:

KT: t ac:

Rated (nominal) turning speed.

Rated Power = Mo • n / 9550

N

Torque constant. Torque generated depending on the supplied current.

Acceleration time of the motor from 0 rpm up to its rated speed at its maximum torque.

L, R:

J:

Winding inductance and resistance between phases.

R otor inertia.

P: Weight.

Metric

Conversion table to mm

Kg·m 2

Nm

°C

Kw

÷ 25.4

÷ 0.113

÷ 0.113

x 1.8

+ 32

÷ 0.746

Imperial inch lb·in·sec 2 lb·in

°F

HP

Peak Torque (Nm) for 0.5 seconds.

VENTILATED

MOTORS

FXM53.12A.xx.xx1

FXM53.20A.xx.xx1

FXM53.30A.xx.xx1

FXM53.40A.xx.xx1

FXM54.12A.xx.xx1

FXM54.20A.xx.xx1

FXM54.30A.xx.xx1

FXM54.40A.xx.xx1

FXM55.12A.xx.xx1

FXM55.20A.xx.xx1

FXM55.30A.xx.xx1

FXM55.40A.xx.xx1

FXM73.12A.xx.xx1

FXM73.20A.xx.xx1

FXM73.30A.xx.xx1

FXM73.40A.xx.xx1

*

FXM74.12A.xx.xx1

FXM74.20A.xx.xx1

FXM74.30A.xx.xx1

*

FXM74.40A.xx.xx1

*

FXM75.12A.xx.xx1

FXM75.20A.xx.xx1

FXM75.30A.xx.xx1

*

FXM75.40A.xx.xx1

*

FXM76.12A.xx.xx1

FXM76.20A.xx.xx1

*

FXM76.30A.xx.xx1

*

FXM76.40A.xx.xx1

**

FXM77.12A.xx.xx1

FXM77.20A.xx.xx1

*

FXM77.30A.xx.xx1

*

FXM77.40A.xx.xx1

**

FXM78.12A.xx.xx1

FXM78.20A.xx.xx1

*

FXM78.30A.xx.xx1

**

FXM78.40A.xx.xx1

**

Mo Mp n N

-Nm-Nm-rpm-

15,0 50,0 1200

15,0 50,0 2000

15,0 50,0 3000

Io Imax Pow

-A-A-kW-

KT

Nm/A tac

-ms-

L R J

-mHr- Ohms Kg.cm2

P

-Kg-

1.08

-Nm-

1.15

-Nm-

1.25

-Nm-

1.35

-Nm-

2.50

-Nm-

2.75

-Nm-

3.100

-Nm-

3,150

-Nm-

3,6

6,0

9,0

12,0

20,0

30,0

15,0 50,0 4000 12,0 40,0

20,4 68,0 1200

20,4 68,0 2000

4,8 16,0

8,3 27,5

20,4 68,0 3000 12,2 40,5

1,9

3,1

4,7

6,3

2,6

4,3

6,4

4,2

2,5

5,8

9,6

88,0

34,0

1,7 14,4 16,0

1,3 19,3

4,3 6,8

9,0

65,0

2,5 11,4 26,0

1,7 17,1 12,0

10,7

4,2

1,9

1,1

7,0

2,8

1,3

23,0 20,0 33,3 50,0

23,0 20,0 37,5 50,0

23,0 20,0

23,0 20,0

37,0 22,0

37,0 22,0

37,0 22,0

63,8

41,7 50,0

31,3 43,8 50,0

68,0

61,8 68,0

42,0 58,8 68,0

20,4 68,0 4000 15,3 51,0

25,5 85,0 1200 6,0 20,0

25,5 85,0 2000 10,2 34,0

25,5 85,0 3000 15,3 51,0

8,5

3,2

5,3

8,0

25,5 85,0 4000 20,0 66,5 10,7

29,3 97,5 1200 7,1 23,5 3,7

29,3 97,5 2000 11,7 39,0 6,1

29,3 97,5 3000 17,0 56,5 9,2

29,3 97,5 4000 23,1 77,0 12,3

39,0 130,0 1200 9,3 31,0 4,9

39,0 130,0 2000 15,6 52,0 8,2

39,0 130,0 3000 23,1 77,0 12,3

39,0 130,0 4000 30,9 103,0 16,3

48,0 160,0 1200 11,6 38,5 6,0

48,0 160,0 2000 19,4 64,5 10,1

48,0 160,0 3000 29,0 96,5 15,1

48,0 160,0 4000 38,0 126,5 20,1

58,5 195,0 1200 14,0 46,5 7,4

58,5 195,0 2000 23,1 77,0 12,3

58,5 195,0 3000 33,9 113,0 18,4

58,5 195,0 4000 46,5 155,0 24,5

67,5 225,0 1200 16,4 54,5 8,5

67,5 225,0 2000 26,0 86,5 14,1

67,5 225,0 3000 39,8 132,5 21,2

67,5 225,0 4000 53,6 178,5 28,3

78,0 260,0 1200 18,8 62,5 9,8

78,0 260,0 2000 30,9 103,0 16,3

78,0 260,0 3000 46,5 155,0 24,5

78,0 260,0 4000 61,8 206,0 32,7

1,3 22,8 6,5

4,3 6,6 51,0

2,5 11,1 20,0

1,7 16,6 9,0

1,3 22,2 5,0

4,1 11,9 58,0

2,5 19,8 22,0

1,7 29,6 10,0

1,3 39,5 6,0

4,2 11,6 44,0

2,5 19,3 16,0

1,7 29,0

1,3 38,6

8,0

4,0

4,2 12,6 34,0

2,5 20,9 13,0

1,7 31,4

1,3 41,9

6,0

3,0

4,2 12,2 29,0

2,5 20,3 12,0

1,7 30,4 5,0

1,3 40,6 3,0

4,1 13,0 25,0

2,6 21,6 10,0

1,7 32,4 4,0

1,3 43,2 3,0

4,2 13,0 23,0

2,5 21,7 8,0

1,7 32,6

1,3 43,5

4,0

2,0

0,7

5,0

2,0

0,9

0,5

4,8

1,8

0,8

37,0 22,0

45,0 24,2

45,0 24,2

45,0 24,2

45,0 24,2

92,0 33,2

92,0 33,2

92,0 33,2

0,5 92,0 33,2

3,1 120,0 35,8

1,2 120,0 35,8

0,6 120,0 35,8

0,3 120,0 35,8

2,2 160,0 40,2

0,8 160,0 40,2

0,4 160,0 40,2

0,2 160,0 40,2

1,8 189,0 44,2

0,7 189,0 44,2

0,3 189,0 44,2

0,2 189,0 44,2

1,5 232,0 47,2

0,6 232,0 47,2

0,3 232,0 47,2

0,1 232,0 47,2

1,3 270,0 51,2

0,4 270,0 51,2

0,2 270,0 51,2

0,1 270,0 51,2

46,7 66,7 68,0

63,8 85,0

62,5 85,0

58,3 83,3 85,0

63,9 85,0

62,2 97,5

62,5 87,5 97,5

60,4 86,3 97,5

63,3 95,0 97,5

104,8 130,0

87,5 125,0 130,0

84,4 126,6 130,0

94,7 126,2 130,0

103,9 145,5 160,0

124,0 160,0

124,4 160,0

126,5 160,0

146,8 195,0

126,6 189,9 195,0

129,4 172,6 195,0

125,8 188,7

144,5 206,4 225,0

195,1 225,0

169,8 225,0

189,1

208,0 260,0

189,3 252,4 260,0

167,7 251,6

189,3

(*)

(**)

Motors with a power "base" which need to be connected via MC 46 type socket.

Motors with a power "base" which need to be connected via MC 80 type socket. All the others with MC 23.

In bold, the combinations where the drive automatically limits its peak current to avoid damaging the motor.

SM.3

DIMENSIONS

Synchronous Motors Ver. 0002 SM - 7

SM - 8 Synchronous Motors

Ver. 0002

Synchronous Motors Ver. 0002 SM - 9

Detail on the internal thread of the shaft.

Detail on power and feedback connectors for FXM motors.

- Power connector for motors with a rated current smaller than 23 Amp. Feedback connector via Resolver ROC 9.

- Power connector for motors with a rated current greater than 23 Amp. Feedback connector via Encoder EOC 12.

- Power connector for motors with a rated current greater than 46 Amp.

- Power connector for optional fan on FXM5 and FXM7 motors

SM - 10 Synchronous Motors

Ver. 0002

Synchronous Motors Ver. 0002 SM - 11

SM.4

BRAKE CHARACTERISTICS

FXM motors have a brake that acts by friction against the shaft. It is used to hold the motor. It

MUST NOT be used to stop the motor when it is turning.

Motor Type

FXM 1

FXM 3

FXM 5

FXM 7

Torque

Nm (in.lb)

2.5 (22.12)

5 (44.25)

12 (106.2)

40 (354)

Maximum

RPM rpm

10000

8000

6000

3600

Power

W (HP)

12 (0.016)

16 (0.021)

18 (0.024)

35 (0.047)

On/Off

Delay ms

7/5

15/7

30/13

100/30

Unlocking voltage margin

Vdc

22 - 26

Inertia

Kg.cm

2 (lb.in

2 )

0,38 (0.13)

1,06 (0.36)

3,6 (1.23)

31,8 (10.86)

Weight

Kg (lbf)

0,3 (0.66)

0,6 (1.32)

1.1 (2.42)

3.5 (7.71)

The brake MUST NEVER exceed its maximum turning speed.

Voltages between 22 and 26 volts release the shaft. Watch that no voltage over 26 V is applied. That would prevent the shaft from turning.

When installing the motor, verify that the brake releases the shaft completely before turning it for the first time.

SM.5

CONNECTORS

SM.5.1

POWER AND BRAKE CONNECTOR

It is a straight male socket connector. It ensures a sealing standard IP65.

There are three different models, for currents up to 23 Amps, 46 Amps or 80 Amps detailed on the previous page. The socket connector of the motors will be connected to straight terminal strips called MC 23, MC 46 and MC 80, or AMC 23 and AMC 46 if they are angled.

Fagor supplies them separately (not with the motor) and upon request.

Only certain motor models carry 46 Amp and 80 Amp connectors. See characteristics tables on the previous pages.

Make sure that the U, V, W and Ground terminals of the Drive are connected to the U1, V1,

W1 and Ground terminals of the Motor respectively.

Otherwise, the motor will not run properly.

SM - 12 Synchronous Motors

Ver. 0002

SM.5.2

FEEDBACK CONNECTOR

Depending on the type of feedback integrated into the motor (encoder or resolver) the connector will be either a 12-pin or a 9-pin.

SM.5.2.1

ENCODER FEEDBACK CONNECTOR

It is a 12-pin male Conney type connector which meets the IP65 sealing standard. The various encoder types available use this connector.

The cable necessary to connect this connector with the drive module is the one referred to as

EEC. Chapter IN describes this cable in detail.

Connector and signals

(front view)

Θ

is the angular rotor position.

ENCODER

1

9

8

2

3

10

11

12

4 5

6

7 REFCOS

REFSIN

2.5V

1V

Θ

Pin

1

2

8

9

6

7

3

4

5

10

12

Signal

REFCOS

+ 485

TEMP

TEMP

SIN

REFSIN

- 485

COS

CHASSIS

0 V

+ 8 Vdc

Function

Reference level for the cosine signal 2.5 Vdc

RS 485 type serial line transmission signal

Thermistor

1 Vpp sinusoidal signal generated by the Encoder.

Reference level for the sine signal 2.5 Vdc

RS 485 type serial line transmission signal

1 Vpp cosinusoidal signal generated by the Encoder.

Metallic housing of the Encoder

Ground

Power for the encoder

Synchronous Motors Ver. 0002 SM - 13

SM.5.2.2

RESOLVER FEEDBACK CONNECTOR

It is a 9-pin male Conney type connector which meets the IP65 sealing standard.

Connector and signals

(front view):

RESOLVER

2

3

1

4

9

5

8

6

7

Pin

1

2

3

4

5

6

7

8

9

Signal

S1

S3

S4

S2

R1

R2

TEMP

TEMP

CHASSIS

Function

Cosinewave signal provided by the Resolver.

Sinewave signal provided by the Resolver.

Sinewave signal for the excitation of the rotating transformer primary.

Thermistor

Resolver body

The cable necessary to connect this connector with the drive module is the one referred to as

REC. IN chapter describes this cable in detail.

The figure shows the typical excitation and output signals of a resolver as well as its equivalent circuit.

SM - 14

E

S1-S3

= K.E

R1-R2.

E

S4-S2

= K.E

R1-R2

Cos

Θ

.Sin

Θ

Resolver Structure

Θ

is the rotating angle of the rotor

Synchronous Motors

Ver. 0002

SM.6

INSTALLATION AND MOUNTING CONDITIONS

Before installing it onto the machine, the anti-rust paint should be removed from the rotor shaft and the flange.

The motor admits the B5, V1 and

V3 mounting methods.

The ambient conditions recommended for the motor are the ones indicated in the general characteristics bearing in mind that:

B5 V1 V3

It must always be in a dry and clean place.

Mounted so it is easily inspected, cleaned and maintained.

Free of corrosive atmosphere and / or explosive gasses or liquids.

If the motor is going to be continuously exposed to oil splashes, it should be protected with a guard.

SM.7

RADIAL AND AXIAL LOADS

The misalignment between the motor and the machine causes vibrations on the shaft and decreases the life span of the roller bearings and couplings.

Please follow these advises in order to avoid those problems:

Use flexible couplings for direct coupling.

Avoid radial and axial loads on the motor shaft which exceed the values in the table below:

Note: For radial and axial loads combined, decrease the value of the permitted radial force Fr to 70% of the table value.

Motor Type

FXM1

FXM3

FXM5

FXM7

Axial Force Fa

105 Nw (23.6 lbf)

138 Nw (31 lbf)

157 Nw (35.3 lbf)

336 Nw (75.5 lbf)

Radial Force Fr

500 Nw (112.4 lbf)

660 Nw (148.3 lbf)

745 Nw (167.4 lbf)

1590 Nw (357.4 lbf)

Distance A

15 mm (0.59")

20 mm (0.78")

25 mm (0.98")

29 mm (1.14")

Fa

Fr

A

When installing pulleys or gears for transmission, avoid hitting the shaft.

Use some tool that is supported in the threaded hole on the shaft to insert the pulley or the gear.

Synchronous Motors Ver. 0002 SM - 15

SM.8

IDENTIFICATION BOARD

Example:

Fagor Automation S. Coop.

(Spain)

AC BRUSHLESS SERVOMOTOR

Type FXM 32.20A.R0.000

Mo 3.9 Nm

Mmax 19.5 Nm

Io 1.5 Amp

Imax 7.5 Amp

BRAKE 24 VDC / 20W

Ver.: 00 SN F170000.01

Nominal Speed: 2000 rpm

B.E.M.F.: 320 v

IP64 W: 12 kg

Iso.cl F

Bal.cl N

SM.9

REGISTRATION NUMBERS FOR FXM MOTORS

Many of the Drive's Software parameters are directly related to the characteristics of the motor it governs. For the Fagor motors in this manual, the software knows the values that must be assigned to those parameters.

Motors equipped with Encoder (sales reference E0, E1 and A0) have their reference stored in their electronic memory, so the drive parameter setting is done

automatically. See the GSU chapter. In a manual setting, one must "tell" the drive which motor is going to govern.

Sales reference coding for synchronous motors.

AXIS MOTORS, FXM Example: FXM 34.30A . E1 . 0 0 0

FAGOR AXIS MOTOR

SIZE

LENGTH

MAXIMUM

SPEED

1, 3, 5, 7

WINDING

12 1200 rpm 20 2000 rpm

30 3000 rpm 40 4000 rpm

A 380 Vac

FEEDBACK TYPE E0 Encoder Sincos TM

(Except for FXM1 type)

E1 Encoder Sincoder TM

A0 Encoder Absoluto Sincos TM

(Except for FXM1 type)

R0 Resolver Tamagawa TM

FLANGE AND

SHAFT

0 With Keyway (Siemens TM 1FT5)

1 Without Keyway

BRAKE OPTION 0 Without brake

1 With standard brake (24 Vdc)

VENTILATION 0 Without Fan

1 With Fan (220 Vac)

SM - 16 Synchronous Motors

Ver. 0002

AM. SPM ASYNCHRONOUS MOTORS

Fagor asynchronous motors, also called induction motors, are designed to work on machinetool spindles.

SPM motors are asynchronous "squirrel cage" motors and are especially designed to work with Fagor drives.

To control the axes of a machine, the

FXM servomotors must be used. They are described in the SM chapter of this manual.

There is a wide range of motors available: from 2.2 Kw to 37 Kw in S1.

The particular characteristics of each motor are described on the following pages.

These motors have been manufactured in compliance with the EN 60204-1 and EN 60034

standards as instructed by the European Directive 89/392/CE on machine safety.

AM.1

GENERAL CHARACTERISTICS

The Class F isolation on the motor maintains its dielectric properties as long as the work temperature is kept below 155°C (311°F).

Motor type.

Thermal protection

Balancing

Mounting

Gear box

Noise

Electrical Insulation

Protection

Storage temperature

Maximum ambient temperature

Maximum ambient humidity

Altitude

Axial fan

Induction. Squirrel cage

Thermistor: klixon N.C. (250 V - 2.5 A)

Degree S -ISO2373-, (SR degree, upon request)

(with the key mounted on the shaft)

IM 2001 B3/B5, (optionally V1/V5, V3/V6)

Special flange (optional)

Meets IEC 34-9 standard class F (155°C) (311°F)

IP 54

Between -20°C and +80°C (-4°F / 176°F)

Between 0°C and +40°C (32°F / 74°F)

Between 20% and 80% (non condensing)

1000 m. (3280 ft) over sea level.

Standard on all models.

Independent power supply.

Brake

Feedback

Optional for all models. 220Vac

Sinewave encoder

Asynchronous Motors Ver. 0002 AM - 1

AM.2

ELECTRICAL CHARACTERISTICS

Electric characteristics table of the new SPMxxx.xx.xxxxx.1 motors:

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

90L

2,2

3,3

14

21

SPM SPM SPM SPM SPM SPM

90P 100LBE 112ME 112LE 112XE 132L

3

4

4

6

5,5

8

7,5

11

11

16

15

22

19

25

25,5

38

35

50

47,7

70

70

101

95,5

140

7,78

11,7

1500

9000

10,13

13,5

1500

9000

13,6

20,4

1500

9000

18,6

27

1500

7500

- - - 9000

0,0035 0,0044 0,0061 0,011

19,2 23,8 35,3 45

24

34,5

1500

7500

9000

0,014

53

33,9

49,3

1500

7500

9000

0,022

70

47,7

70

1500

7500

9000

0,062

108

(*) Maximum speed when special bearings are used. Optional.

Small motors reach 9000 rpm with their roller bearings.

56,2

79

1500

7500

9000

0,07

119

SPM SPM SPM

132X 132XL 160M

18,5

26

22

28

22

33

118

165

140

178

140

210

62,3

79,3

1500

7500

9000

0,07

119

65,5

98,3

1500

7000

9000

0,13

158

Metric mm

Kg·m 2

Nm

°C

Kw

Conversion table to

÷ 25.4

÷ 0.113

÷ 0.113

x 1.8

+ 32

÷ 0.746

Imperial inch lb·in·sec 2 lb·in

°F

HP

SPMxxx.xx.xxxxx.0 motors differ from these only on the values of their current:

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

90L

2,2

3,3

14

21

6,4

9,5

1500

9000

SPM SPM SPM SPM SPM

90P 100LBE 112ME 112LE 112XE 132L

3

4

19

25

8,26

11

1500

9000

4

6

25,5

38

11,1

16,7

1500

9000

5,5

8

35

50

15

21,7

1500

7500

- - - 9000

0,0035 0,0044 0,0061 0,011

19,2 23,8 35,3 45

7,5

11

47,7

70

19,7

28,3

1500

7500

9000

0,014

53

11

16

70

101

28,8

40,3

1500

7500

9000

0,022

70

SPM

9000

0,062

108

15

22

95,5

140

39

57,2

1500

7500

SPM SPM SPM

132X 132XL 160M

18,5

26

118

165

46

67

1500

7500

9000

0,07

119

22

28

140

178

51

64,9

1500

7500

9000

0,07

119

9000

0,13

158

22

33

140

210

53,6

77,3

1500

7000

(*) Maximum speed when special bearings are used. Optional.

Small motors reach 9000 rpm with their roller bearings.

(**) The maximum power in S6-40% will be 43.3 kW (SPM 160L) and 45 kW (SPM 180MA) with SPM3.150 drives.

SPM SPM

160L 180MA

30 37

45 (**) 55 (**)

191

286

235

350

76

114

1500

6300

87

129

1500

6500

9000

0,17

196

9000

0,34

260

AM.3

FAN CHARACTERISTICS

Power supply

Voltage (frequency)

Current

Power

V (Hz)

A

W

SPM

90L

0.3

40

SPM SPM SPM SPM SPM SPM

90P 100LBE 112ME 112LE 112XE 132L single-phase

220 (50/60)

0.36

80

SPM SPM SPM

132X 132XL 160M

SPM SPM

160L 180MA

0.6

130 115

0.55

120

AM.4

BRAKE CHARACTERISTICS (OPTIONAL)

Power supply

Power

Continuous torque

Inertia

SPM

90L

W

Nm

Kg.m2

16

10

0.00011

SPM SPM SPM SPM SPM SPM

90P 100LBE 112ME 112LE 112XE 132L

22

30

0.0003

220

25

50

0.00057

SPM SPM

132X 132XL

29

150

0.0023

SPM

160M

SPM

160L

SPM

180MA

Upon request

AM.5

CHARACTERISTICS OF THE ROLLER BEARINGS

Drive end

Non-drive end

Radial load -Fr-

-X- distance

Axial load

N mm

N

SPM

90L

SPM SPM SPM SPM SPM SPM

90P 100LBE 112ME 112LE 112XE 132L

6205 Z 6206 Z 6207 Z

6205 Z 6205 Z 6205 Z

800

25

900 1300

40

400 450 800

1600

1000

6209 Z

6205 Z

40

1800

1100

SPM SPM

132X 132XL

6209 Z

6209 Z

1800

55

1100

SPM

160M

6310 Z

6309 Z

2300

55

1400

SPM

160L

SPM

180MA

6311 Z

6311 Z

3700

55

2300

This table refers to the motor bearings for horizontal mounting B3/B5. It is not valid for other types of mounting.

The graph shows how the radial force permitted on the axis decreases as the turning speed increases. The illustration on the right shows the radial force applied onto the axis (Fr) and distance to the roller bearings.

B3/B5

AM.6

POWER AND TORQUE CHARACTERISTICS

The following sections show the electrical and mechanical characteristics of power and torque for each SPM motor.

The Power-Speed curves are shown for the S1 and S6 cycles at 40%.

Over the curves for each motor, the powers that may be reached with the various Fagor

Drives are also indicated. This is very useful for selecting the right drive for each motor and application.

Very important: It is assumed that the drive system is powered at 380 Vac from Mains.

The following graphics indicate how the temperature and the altitude over sea level affect the properties of the SPM motors. They also indicate the meaning of duty cycles S1 and S6 according to international standards.

POWER/AMBIENT

CHARACTERISTIC

DUTY CYCLES

According to the

IEC 34-1

110

100

90

80

70

60

50

S1 Cycle

N (thermal equilibrium)

40°

50°

60°

4000 1000 2000 altitude a.s.l. (m)

3000

S6-40% Cycle

10 min

N V N/V=4/6

Θ max

Θ max

N: Rated

V: Without Load

Asynchronous Motors Ver. 0002 AM - 5

SPM 90L

SPM 90P

AM - 6

4

3

2

1

6

5

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 90L .1

1.25 Drive

S6-40%

S1

1.15 Drive kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

90L

2,2

3,3

14

21

7,78

11,7

1500

9000

- -

0,0035

19,2

1000 2000 4000 speed (rpm)

6000 8000

1.25 Drive

S6-40%

1.15 Drive

S1

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 90P .1

4

3

2

1

6

5

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

90P

3

4

19

25

10,13

13,5

1500

9000

- -

0,0044

23,8

1.25 Drive

S6-40%

1.15 Drive

S1

Asynchronous Motors Ver. 0002

SPM 100LBE

SPM 112ME

Asynchronous Motors Ver. 0002

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 100LBE .1

7

6

5

9

8

4

3

2

1

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

100LBE

4

6

25,5

38

13,6

20,4

1500

9000

- -

0,0061

35,3

1.35 Drive

S6-40%

1.25 Drive

S1

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 112ME .1

6

4

2

10

8

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

112ME

5,5

8

35

50

18,6

27

1500

7500

9000

0,011

45

1.35 Drive

S6-40%

1.25 Drive

S1

AM - 7

SPM 112LE

SPM 112XE

AM - 8

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 112LE .1

14

12

10

8

6

4

2

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

112LE

7,5

11

47,7

70

24

34,5

1500

7500

9000

0,014

53

2.50 Drive

S6-40%

1.35 Drive

S1

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 112XE .1

18

16

14

12

10

8

6

4

2

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

112XE

11

16

70

101

33,9

49,3

1500

7500

9000

0,022

70

2.75 Drive

S6-40%

2.50 Drive

S1

Asynchronous Motors Ver. 0002

SPM 132L

SPM 132X

Asynchronous Motors Ver. 0002

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 132L .1

30

25

20

15

10

5

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

132L

15

22

95,5

140

47,7

70

1500

7500

9000

0,062

108

3.100 Drive

S6-40%

2.75 Drive

S1

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 132X .1

30

25

20

15

10

5

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

132X

18,5

26

118

165

56,2

79

1500

7500

9000

0,07

119

3.100 Drive

S6-40%

S1

AM - 9

SPM 132XL

SPM 160M

AM - 10

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 132XL .1

kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

132XL

22

28

140

178

62,3

79,3

1500

7500

9000

0,07

119

20

10

40

30

1000 2000 4000 speed (rpm)

6000 8000

3.150 Drive

3.100 Drive

S6-40%

S1

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 160M .1

35

30

25

20

15

10

5

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

160M

22

33

140

210

65,5

98,3

1500

7000

9000

0,13

158

3.150 Drive

S6-40%

3.100 Drive

S1

Asynchronous Motors Ver. 0002

SPM160L

SPM180MA

Asynchronous Motors Ver. 0002

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 160L .0

50

40

30

20

10

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

160L

30

45

191

286

76

114

1500

6300

9000

0,17

196

S6-40%

3.150 Drive

3.100 Drive

S1

Rated power S1

Rated power S6-40%

Rated Torque S1

Rated Torque S6-40%

Rated current S1

Rated current S6-40%

Rated speed

Maximum speed

Maximum speed (*)

Inertia

Weight

SPM 180MA .0

60

50

40

30

20

10

1000 2000 4000 speed (rpm)

6000 8000 kW kW

Nm

Nm

Arms

Arms rpm rpm rpm

Kg·m2

Kg

SPM

180MA

37

55

235

350

87

129

1500

6500

9000

0,34

260

S6-40%

3.150 Drive

S1

AM - 11

AM.7

DIMENSIONS

.15)

.3)

80 (3

160 (6

.54) 90 (3

200

.87)

(7

165

(6

.49)

.12) 130 (5 ø

.68) 17.5 (0

.5) 89 (3

.69) 43 (1

AM - 12 Asynchronous Motors Ver. 0002

.5) 89 (3

.15)

.3)

80 (3

160 (6

.54) 90 (3

200

.87)

(7

165

(6

.49)

.12) 130 (5 ø

.68) 17.5 (0

Asynchronous Motors Ver. 0002 AM - 13

AM - 14

.41) 10.5 (0

.94)

7)

100 (3

261 (10.2

.94) 100 (3

250

(9

.84)

.46)

215

(8

.08) ø 180 (7

.5) 89 (3

.4) 61 (2

Asynchronous Motors Ver. 0002

.5) 89 (3

.4) 61 (2

.41)

2)

112 (4

285 (11.2

.41) 112 (4

250

.84)

(9

215

(8

.46)

.08) 180 (7

Asynchronous Motors Ver. 0002 AM - 15

.5) 89 (3

.4) 61 (2

.41)

2)

112 (4

285 (11.2

.41) 112 (4

250

.84)

(9

215

(8

.46)

.08) 180 (7

AM - 16 Asynchronous Motors Ver. 0002

.5) 89 (3

.41)

2)

112 (4

285 (11.2

.41) 112 (4

250

.84)

(9

215

(8

.46)

.08) 180 (7

Asynchronous Motors Ver. 0002 AM - 17

.5) 89 (3

.11) 206 (8

338 (13.3)

.19) 132 (5

265

(10.43)

300

(11.81)

.05) 230 (9

ø

AM - 18 Asynchronous Motors Ver. 0002

.5) 89 (3

9.07) 230.5 (

.37) 15 390.5 (

.3) 160 (6

300

(11.81)

350 (13.78)

.84) 250 (9

1/2" G

Asynchronous Motors Ver. 0002 AM - 19

.5) 89 (3

9.07) 230.5 (

.37) 15 390.5 (

.3) 160 (6

300

(11.81)

350 (13.78)

.84) 250 (9

1/2" G

AM - 20 Asynchronous Motors Ver. 0002

) 100(3.94

.08) 180 (7

) 465 (18.3

350

.08) 180 (7

400

(15.75)

1) 300 (11.8

S 1/2" GA

.5) 89 (3

Asynchronous Motors Ver. 0002 AM - 21

AM.8

CONNECTORS

1 2

3

2

3

1

Terminal box for power and brake (option) connection.

Encoder feedback connector

Terminal box or connector for the fan (the

1

,

2

,

3

, name is not printed on the motor)

AM.8.1

POWER AND BRAKE CONNECTION

It is done through an internal terminal box.

* Power terminals.

* Internal thermal switch contacts (Klixon 150°C (302°F)).

* Brake contacts as an option.

There is internal thermal switch as a protection against overtemperature. It is a normally closed contact that opens when the temperature exceeds 150°C (302°F). It has no polarity and withstands up to 250V/2.5A. This contact should be included in the Emergency chain.

Make sure that the U, V, W and Ground terminals of the Drive Module are connected

to the U1, V1, W1 and Ground terminals of the Motor respectively. Otherwise, the motor would not work properly.

For further information about the characteristics of the power supply cables for the asynchronous motors as well as the selection criteria, see chapter IN.

To control the brake a single-phase mains (220 Vac) connection is needed.

The brake must be released when applying these 220 Vac. That way, in case of a power outage, the motor will be braked.

The windings of the motor have a star connection (as shown here) and it cannot be changed for any reason because it would make it run improperly.

Star

Connection

AM - 22 Asynchronous Motors Ver. 0002

AM.8.2

FEEDBACK CONNECTION. ENCODER

It is done through a 12-pin male Conney connector which assures a sealing degree of IP65.

The various available encoder models use this connector.

The cable required to connect this connector with drive module is the one referred to as EEC.

Chapter IN describes this cable in detail.

Connector and signals (front view).

Θ

is the angular rotor position.

ENCODER

1

9

8

2

3

10

11

12

4 5

6

7 REFCOS

REFSIN

2.5V

1V

Θ

Pin

1

2

7

8

9

10

12

5

6

3

4

Signal

REFCOS

+ 485

TEMP

TEMP

SIN

REFSIN

- 485

COS

CHASSIS

0 V

+ 8 Vdc

Function

Reference level for the cosine signal 2.5 Vdc

RS 485 type serial line transmission signal

Thermistor

1 Vpp sinusoidal signal generated by the Encoder.

Reference level for the sine signal 2.5 Vdc

RS 485 type serial line transmission signal

1 Vpp cosinusoidal signal generated by the Encoder.

Metallic housing of the Encoder

Ground

Power for the encoder

AM.8.3

FAN CONNECTION

The fan is always supplied with 220Vac. On most motors, it is carried out through a terminal box. Only SPM90 motors use a connector that is provided with the motor (maximum cable section, 2.5 mm 2 ).

A previous section describes the characteristics of the fans.

Asynchronous Motors Ver. 0002 AM - 23

AM.9

INSTALLING RECOMMENDATIONS

The motor should be installed in a clean, dry and well ventilated place.

It should be easily accessible for inspection and maintenance.

There must be a gap between the armature of the motor and the structure of the machine

NEVER SMALLER than 5 mm in order to avoid electromagnetic interference and transmission of vibration.

Make sure that air circulates around the motor.

Provide an unobstructed air entry and output for the fan.

AM - 24 Asynchronous Motors Ver. 0002

AM.9.1

VENTILATION

SPM series motors carry an electric fan that generates a constant air flow regardless of the motor speed. That way, proper cooling is assured for any working condition. The motors can run at their rated current or peak current at low speeds without losing their specifications.

The electric fan must be turned on before powering the motor and must never be stopped while the machine is on.

Important:

Make sure that the air taken in by the fan is always fresh, clean and dry. For motors installed inside the structure of another machine and/or protected by panels or other type of covers, it is absolutely essential that the air comes in from the atmosphere through the corresponding conduit and channel system and that it is sent back out through the ventilation openings. The fresh air intake and the hot air outlet must be as far apart from each other as possible. In any case, make sure that the hot air (going out) and the fresh air (coming in) are not mixed.

AM.9.2

MOUNTING OPTIONS

These motors may be supplied as to be mounted horizontally B3/B5 (feet/flange) or vertically types: V1/V5 or V3/V6. The motor nomenclature indicates the mounting type. See appendix C.

The motor must be fitted onto a flat, solid and sturdy surface. If the motor suffers excessive vibrations, it is often due to the weakness of the base supporting it.

When foot-mounted, the supports are located on the base of the motor itself and its dimensions and supports are standard. The motor must be mounted onto a perfectly flat surface in order to avoid deforming and breaking the protections which could cause contact between the rotor and the stator. If necessary, step up the motor support until perfectly flat and uniform motor mounting is achieved. Any element used to step it up must be made of the proper material and not smaller, in dimensions, than the motor foot itself.

Secure the motor with the right size bolts, nuts and self-locking washers. Make sure that the tools used to secure the motor do not interfere with its operation or damage it.

B3/B5 V1/V5 V3/V6

Asynchronous Motors Ver. 0002 AM - 25

AM.9.3

AMBIENT CONDITIONS

Before mounting it onto the machine, the anti-rust paint should be removed from the rotor shaft and the flange.

The environmental conditions recommended for the motor are the ones indicated in the general characteristics bearing in mind that:

· It must be located in a clean and dry place.

· Easily accessible for inspection, cleaning and maintenance.

· Free of corrosive ambient and explosive gasses or fluids.

· If the motor is going to be exposed to oil splashes, it should be cover with a guard.

When installing it in difficult areas due to dust, water, too much humidity, vapor, smokes, oil, solvents, etc. a motor meeting a higher sealing standard may be ordered.

None of the motors described in this manual can be installed in places with any risk of explosion.

AM.10 COUPLING

The circular motion of the motor can be transmitted to the machine through direct coupling or by using pulleys or gear boxes.

AM.10.1 DIRECT COUPLING

Use a joint which does not transmit axial loads to the roller bearings and does not compensate for alignment errors between the transmission shafts. In the case of direct coupling (linked shafts) be extra careful in order to guarantee the alignment between the motor shaft and the pulled axis and between the coupling flanges. Any vibration or irregular rotation will indicate poor alignment which will result in poor performance and shorter life-span of the bearings.

AM.10.2 COUPLING THROUGH TRANSMISSION PULLEYS

Install the motor with shaft perfectly parallel and aligned with the pulley shaft in order to avoid axial loads on the supports. The tension of the pulleys must be enough to avoid slippage when the motor is working at full load, but it must never exceed the maximum load described in this manual. Too much tension on the pulleys may wear out the bearings faster and even break the shafts.

Regarding the peripheral speed of the pulleys, transmitted power, diameter ratios of the pulleys, etc. Refer to the technical data supplied by the manufacturer. Always use balanced pulleys.

AM - 26 Asynchronous Motors Ver. 0002

AM.10.3 COUPLING THROUGH GEAR BOXES

Refer to the "direct coupling" section and to any information provided by the manufacturer of the gear boxes.

AM.10.4 BALANCING

The rotor is dynamically balanced with the key inserted in the keyway. It is an "S" degree balancing and, upon request, an "SR" degree can be obtained. It is important that the pulley, half-joint or rack be dynamically balanced (without the key) before inserting them in the transmission shaft. Any vibration while the motor is running indicates an unbalanced gear box and must be corrected.

AM.10.5 MOUNTING THE GEAR BOXES

Upon request, the motor may carry a special flange for mounting gear boxes.

The joints, pulleys, pinions, etc. must always be adjusted very accurately and with the right tools. Never use a hammer since it can damage the bearings and accessories, especially those of the feedback device.

Before manipulating the gear box, remove the anti-rust paint from the motor shaft by using alcohol or the proper solvent (the solvent must not get into the bearings). Do not use sandpaper or any other abrasive element to remove the paint.

Lubricate the end of the shaft and the keyway before inserting the transmission and assemble it by following the manufacturer's instructions.

AM.11 RADIAL AND AXIAL LOADS

A poor alignment between the motor and the machine increases the vibrations on the shaft and reduces the life-span of the bearings and couplings.

In order to avoid these problems, follow these advises::

· Use flexible couplings when the coupling is direct.

· Avoid radial and axial loads onto the motor shaft, making sure that they do not exceed the values indicated in the table at the beginning of the chapter.

Note: For combined axial and radial loads, decrease the value of the allowed radial force to

70%.

When installing pulleys or gears for transmission, avoid hitting the shaft.

Use some tool supported in the threaded hole of the shaft to insert the pulley or the gear.

Asynchronous Motors Ver. 0002 AM - 27

AM.12 BEARINGS

The special bearings are the ball-bearing type, suitable for high speeds and lubricated with special greases resistant to high rotation and temperature conditions.

The maximum theoretical life of the bearings is calculated in about 20,000 hours of continuous operation at 1500 rpm approx. For higher average rotation speeds, the life of the bearings varies as follows:

30 - 50% of n max .

50 - 60% of n max .

– about 16,000 hours

– about 12,000 hours

60 - 70% of n max .

– about 8,000 hours

The data and the operating hours are calculated for normal operating conditions, without vibrations and with temperatures within the limits imposed by the bearing manufacturers.

The speed n max

is to intended as the maximum limit of rotation and not as continuous operating speed, which is limited to about 70% of n max

.

Notes:

On the non drive side, a rigid radial ball bearing is always installed.

For coupling with a pulley, the radial load acting on the shaft can be calculated using the following formula:

Fr

=

.

⋅ 6 ⋅ ±

Pp

Fr = Radial load in [N]

Nn = Nominal speed in [rpm]

Pp = Weight of pulley in [N]

Pn = Nominal power in [kW]

D = Diameter of pulley in [mm]

K = 1 - 1.5 for cog belts

2 - 2.5 for V-belts

3 - 4 for flat belts

Caution: It is advisable, at the first start up of the motor, to carry out the breaking-in of the bearings. Increase progressively the velocity of the motor from 0 to about 70% of n max in about

20 min. Never operate the motor at the maximum speed for long periods of time.

Watch the temperature and possible abnormal noises.

During the first minutes of operation, a higher than normal noise can be heard, due to the non uniform distribution of the grease inside the bearing. The noise should return back to normal at the end of the break-in.

As for special bearings (high speed for spindles), the break-in operation is a must.

During the break-in, the fan must be in operation. Clamp securely the key before starting the motor.

Any gasket or seal rings installed as protection for the bearing can be removed only if not deemed necessary to the purpose (particularly clean environment, additional external mechanical protections). By doing so, the friction and the operating temperature will decrease.

AM - 28 Asynchronous Motors Ver. 0002

AM.13 MAINTENANCE INTERVALS

First inspection: in normal cases and after about 500 hours of operation, at any rate within a year from start-up date. Check that the plate data are followed and there are no vibrations, noises, high temperatures or structural damages to the motor and accessories.

Re-lubing of bearings:

Fagor recomends the lube oil from KLUBER (ISOFLEX LDS 18 SPECIAL A).

Depending on the type of bearing, dimensions, average speed and operating and temperature conditions. From a minimum of about 1000 hours to a maximum of 8000 hours. At any rate within 3 years.

a) Re-lube the bearings by putting in new grease of the same type or compatible with the existing one.

b) Do not exceed the quantity of grease which could cause high temperatures and contamination of the motor windings. The following formula can be used to establish the quantity of grease to be put in:

Gp = D * B * 0,005

Gp = quantity of grease to be put in [gr]

D = external bearing diameter [mm]

B = bearing height [mm]

Replacement of the bearings: at the most, after 20000 hours of operation a) Replace the bearings following the instructions indicated in the next paragraph.

b) The type and name of the bearing is indicated in the manual.

AM.13.1 BEARING REPLACEMENT

1) Extract the rotor from the stator paying the utmost attention not to damage the windings.

2) Position the rotor on a stable support and block it in order to prevent its rotation or accidental fall.

3) Extract the bearing using a specific extractor inserting a copper or aluminum plate between the shaft and the extractor’s pin in order not to damage the shaft or the thread, if any.

4) Do not exert any pressure on the encoder/resolver shaft. Use a bushing if necessary.

5) Replace the bearing with others of the same type and dimension (pay attention to the complete denomination indicated on the bearing).

6) In order to assemble the new bearings, use the specific tool or assemble it by warming it up (max 100 ºC).

7) The use of a hammer is specifically forbidden.

8) Lube the non shielded bearings and proceed with the motor assembly. (For the grease quantity to be put in and the type, please see the bearing manufacturer catalog).

9) At the end of the operation proceed to the break-in of the bearings, if necessary.

Asynchronous Motors Ver. 0002 AM - 29

AM.14 IDENTIFICATION BOARD

The identification plate of each motor has the shape shown in the next figure.

3 Phase

Fagor Automation

S. Coop. (Spain)

AC Induction Motor

Type SPM 112LE.E1.00000.1 Rel. C SN 96L 1078 Year 1999

S1

Pn 7.5 kW

In 24 A

S6

P 11 kW

I 34.5 A

Vn 330 Vac

Nm 47.7 Nm

Slip 55 rpm

Hz 50

Conn.

IP 54

Speed Nn/Nmax 1500/7500 rpm

Magnetizing current 11.4 A

Resistance (ph/ph) 0.44

Inductance (ph/ph) 5.3 mH

W 53 kg

M V1/V5

I. cl F

B. cl S

Transducter type Stegman

Brake type

Electric Fan type R2E190 Ph1 V 220 A 0.35 Hz 50/60 IP54

AM.15 REGISTRATION NUMBERS FOR SPM MOTORS

Many of the Drive's Software parameters are directly related to the characteristics of the motor it governs; see appendix A. For the Fagor motors in this manual, the software knows the values that must be assigned to those parameters.

Motors equipped with Encoder (sales reference E0, E1) have their reference stored in their electronic memory so the parameter setting at the drive is done automatically.

See the GSU chapter. In a manual setting, the drive must be "told" which motor is going to govern.

Appendix C shows the codes of this reference for asynchronous motors. These identifiers

(motorid) are followed by the version release identifier (Rel) in all cases.

For example: SPM112LE.E1.00000.1-C

AM - 30 Asynchronous Motors Ver. 0002

EM. ELECTRONIC MODULES

The Fagor Servo-Drive System has a modular stackable design.

It is connected directly to a three-phase mains of 50/60 Hz with a rated voltage between

380Vac-15% and 460Vac+10%. It supplies the motors with three-phase 380 Vac and variable frequency to control its speed.

Depending on the user's needs, it may consists of the following elements:

Power Supply Module.

Regenerative Power Supply

Modular Drive

Compact Drive

PS. Module in charge of converting the alternating current of mains into dc voltage for the drives.

XPS. Power Supply with the possibility to return energy to Mains.

AXD, SPD. They are fully digital modules which can govern a synchronous and an asynchronous motor respectively.

ACD, SCD. Autonomous modules for governing a synchronous and asynchronous motor respectively

Auxiliary Power Supply Module.

APS 24. Module in charge of supplying 24 Vdc to the control circuits of the rest of the modules.

Capacitor Module.

Resistor Module.

CM-60. Increases the capability of the Bus and it serves as a temporary energy buffer.

RM-15, ER. To facilitate a great energy dissipation while braking.

Programming Module.

DDS PROG MODULE. Connected to the drive module through the serial line, it allows displaying and programming its internal parameters. It has an internal nonvolatile memory and the possibility to send and receive parameter tables.

Mains Filter EMK. Additional module to protect mains and the Drive System against mutual disturbances. Optional although absolutely necessary for complying with the European Directive on

Electromagnetic Compatibility 89/336/CE or the international standard CEI/IEC 1800-3.

The following illustrations show all these elements: Power Supplies, Modular Drives in three possible sizes, Compact Drives, Programming Module, Auxiliary Power Supply, Capacitor and

Resistor Modules as well as the Mains Filters.

This system has been manufactured in accordance with the EN 60204-1 standard in compliance with European Directive 73/12/CE on Low Voltage.

Electronic Modules Ver. 0002 EM - 1

EM - 2 Electronic Modules Ver. 0002

Electronic Modules Ver. 0002 EM - 3

EM - 4 Electronic Modules Ver. 0002

EM.1

POWER SUPPLY MODULE

They are directly connected to 380-460 Vac, 50/60 Hz Mains and provide a dc voltage output of about 600 Vdc depending on Mains power. This voltage supplies to the Drive Modules through what we call Power Bus.

These Power Supplies also handle the energy excess accumulated at the Power Bus usually due to motor braking.

We call them Non-regenerative Power Supplies when this excess of energy is dissipated as heat on certain electrical resistors.

We call them Regenerative Power supplies when this excess of energy is returned to Mains.

This option reduces the consumption of the electrical signal without generating additional heat.

Non-regenerative Power Supplies

They are the ones referred to as PS-25A, PS-25B and PS-65A, and provide 25 and 65 kilowatts to the Drives respectively. They admit a voltage range between 380 Vac to 460 Vac.

The previous PS-25 and PS-65 only admitted 380 Vac. See appendix D.

Regenerative Power supplies

They are the ones referred to as XPS-25 and XPS-65, (25 and 65 kilowatts) and they can return 16 and 41 kilowatts respectively in a continuous fashion.

They admit a voltage range between 380 Vac and 460 Vac.

When energy regeneration is activated, the "REGEN" lamp turns on.

The module also has a little Ballast Circuit for dissipating energy in an emergency. That is, when there is no Mains voltage and the overvoltage alarm goes off.

These modules also offer an Auxiliary 24 Vdc Power Supply for the control circuits of the Drive modules.

25 kW

RM-15

Internal

Ballast

1.5 kW

520 W

PS-25A or

PS-25B

Power

25 kW

16 kW

XPS-25

Power

65 kW

2xRM-15

Internal

Ballast

3 kW

600 W

PS-65A Power

65 kW

41 kW

XPS-65

Power

Electronic Modules Ver. 0002 EM - 5

EM.1.1

GENERAL CHARACTERISTICS OF THE NON-

REGENERATIVE POWER SUPPLIES

Power supply (Vmains)

Mains power consumption

Maximum connection cable section

PS-25A Module PS-65A Module

Three-phase 50/60 Hz, with a voltage range between 380Vac -15%. and 460Vac +10% (**)

38 Amp -RMS-

4 mm 2

100 Amp -RMS-

50 mm 2

Power bus voltage VBUS

NOM

Rated (peak) output current (*)

Rated (peak) output power

Power for the module control circuit

Consumption of the module control circuit itself

Internal Ballast resistance (Power (*))

Energy pulse to be dissipated

Ballast circuit On/Off

Minimum external Ballast resistance

Filter capacity

Energy stored in the capacitors

Maximum "System OK" contact voltage

Maximum "System OK" contact current

540 Vdc / 650 Vdc

45 Amp (135 Amp, 1 sec)

25 kW (75 kW, 1 sec)

24 Vdc (between 21 Vdc and 28 Vdc)

1 Amp at 24 Volts (24 watts)

18 Ohms (520 W)

18 kWs (0.6 sec)

705 microF, 900 Vdc

120 Amp (360 Amp, 1 sec)

0.5 · C · V 2

65 Kw (195 kW, 1 sec)

125 Vac, 150 Vdc

2 Amp

9 Ohms (600 W)

36 kWs (0.6 sec)

768 Vdc / 760 Vdc (712 Vdc / 704 Vdc (***))

18 Ohms 9 Ohms

750 microF, 900 Vdc

Module width

Module weight

Power dissipated at maximum load

Ambient temperature (*)

Storage temperature

Humidity

Maximum altitude without loss of features

Operating vibration

Shipping vibration

Sealing

Protections

(*) See derating curves in case of high temperatures

(**) Previous power supplies PS-xx only admitted Vmains of 380 Vac

(***) When the module is set for Vmains = 380 Vac

77 mm (3.03 inches)

6.8 Kg (15 lbs)

117 mm (4.61 inches)

9.9 Kg (22 lbs)

160 W

5°C / 45°C. (41°F / 113°F)

275 W

-20°C / 60°C (-4°F / 140°F) less than 95% (non-condensing at 45°C / 113°F)

1000 meters (3281 ft) above sea level

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP2x

Over-voltage, heat-sink temperature, hardware error, Ballast overload

EM - 6

IMPORTANT NOTE: PS-25A and PS-65A power supplies admit a mains voltage of up to 460 Vac. The rest of their characteristics, connectors and so forth of previous PS-25 and PS-65 are identical.

See appendix D for compatibility with the drives.

Electronic Modules Ver. 0002

Power supply (Vmains)

Mains power consumption

Maximum connection cable section

PS-25B Module

Three-phase 50/60 Hz, with a voltage range between 380Vac -15%. and 460Vac +10% (**)

38 Amp -RMS-

10 mm 2

Power bus voltage VBUS

NOM

Rated (peak) output current (*)

Rated (peak) output power

Internal Ballast resistance (Power (*))

Energy pulse to be dissipated

Ballast circuit On/Off

Minimum external Ballast resistance

Filter capacity

Energy stored in the capacitors

540 Vdc / 650 Vdc

45 Amp (135 Amp, 1 sec)

25 kW (75 kW, 1 sec)

18 Ohms (400 W)

35 kWs (1 sec)

768 Vdc / 760 Vdc (712 Vdc / 704 Vdc (***))

18 Ohms

705 microF, 900 Vdc

0.5 · C · V 2

Maximum "System OK" contact voltage

Maximum "System OK" contact current

125 Vac, 150 Vdc

2 Amp

Module width

Module weight

Power dissipated at maximum load

Ambient temperature (*)

Storage temperature

Humidity

Maximum altitude without loss of features

Operating vibration

Shipping vibration

Sealing

Protections

(*) See derating curves in case of high temperatures

(**) Previous power supplies PS-xx only admitted Vmains of 380 Vac

(***) When the module is set for Vmains = 380 Vac

77 mm (3.03 inches)

6 Kg (13.2 lbs)

180 W

5°C / 45°C. (41°F / 113°F)

-20°C / 60°C (-4°F / 140°F) less than 95% (non-condensing at 45°C / 113°F)

1000 meters (3281 ft) above sea level

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP2x

Over-voltage, heat-sink temperature, hardware error, Ballast overload

Output voltage , maximum current

Input voltage

Mains consumption

Maximum inrush current

Bus consumption

Bus maximum voltage

24 Vdc (5%), 10 Amp

380 Vac (-15%) - 460 Vac (+10%); 50/60 Hz

0.75 Amp (380 Vac) 0.63 Amp (460 Vac)

23.9 Amp (460 Vac)

0.5 Amp (540 Vdc) 0.44 Amp (650 Vdc)

790 Vdc

IMPORTANT NOTE: The PS-25B model power supply admits a Mains voltage of up to 460 Vac.

See appendix D to know about compatibility with the drives.

Electronic Modules Ver. 0002 EM - 7

EM.1.2

GENERAL CHARACTERISTICS OF THE REGENERATIVE

POWER SUPPLIES

Power supply (Vmains)

Mains power consumption

Maximum connection cable section

Voltage of the Power Bus. VBUS

NOM

Rated (peak) output current (*)

Rated (peak) output power

Regenerating circuit on/off voltage

Rated regenerated current (returned to mains) (*)

Rated regenerative power (returned to mains)

Related Choke

Choke-Drive Cable (max. length: 2 m (80 inches))

Output voltage of the Auxiliary Power Supply

Maximum current supplied

Mains consumption for 24 Vdc generation

Internal Ballast resistance (Power (*))

Energy pulse that could be dissipated

Ballast circuit On/Off voltage

Minimum external Ballast resistance

Filter capacity

Energy stored in the capacitors

Maximum "System OK" contact voltage

Maximum "System OK" contact current

Module width

Module weight

Power dissipated at maximum load

Ambient temperature (*)

Storage temperature

Humidity

Maximum altitude without loss of features

Operating vibration

Shipping vibration

Sealing

Protections

(*) See derating curves in case of high temperatures

(***) When the module is set for Vmains = 380 Vac

XPS-25 Module XPS-65 Module

Three-phase 50/60 Hz, with a voltage range between 380Vac -15%. and 460Vac +10%

38 Amp -RMS100 Amp -RMS-

16 mm 2 50 mm 2

540 Vdc / 650 Vdc

45 Amp (100 Amp, 1 sec)

25 kW (55 kW, 1 sec)

120 Amp (120 Amp, 1 sec)

65 kW (108 kW, 1 sec)

Vmains x 1.414 + 30V

25 Amp -RMS62 Amp -RMS-

16 kW

CHOKE XPS-25

16 mm 2

41 kW

CHOKE XPS-65

50 mm 2

24 Vdc ± 5%

8 Amps at 24 Volts (192 watts)

0.75 Amp (380 Vac) 0.63 Amp (460 Vac)

18 Ohms (520 W) 9 Ohms (1800 W)

18 kWs (0.6 sec) 50 kWs (1 sec)

765 Vdc / 755 Vdc (616 Vdc / 608 Vdc (***))

18 Ohms

1175 microF, 900 Vdc

0.5 · C · V 2

9 Ohms

2115 microF, 900 Vdc

125 Vac, 150 Vdc

2 Amp

194 mm (7.64 inches) 234 mm (9.21 inches)

14 Kg (31 lbs)

180 W

19 Kg (42 lbs)

5°C / 45°C. (41°F / 113°F)

350 W

-20°C / 60°C (-4°F / 140°F) less than 95% (non-condensing at 45°C / 113°F)

1000 meters (3281 ft) above sea level

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP20

Overvoltage, Overcurrent, ambient temperature, hardware error.

EM - 8 Electronic Modules Ver. 0002

EM.1.3

POWER SUPPLY CONNECTORS

1. Power connectors for Mains.

2. Power connectors for the external Ballast resistor.

3. Ground connector for the cable hose from Mains and intermodular Chassis connections.

4. Lamps indicating the status of the Main Power Supply.

“FAULT”. When blinking, it indicates that one or several Mains phases are missing.

“FAULT” on, it indicates an error specified at the display of the drives.

"BALLAST" it comes on when the energy dissipating Ballast circuit is activated.

“DC BUS ON” comes on when the module offers all its power at the Bus.

And at the XPS:

“REGEN” comes on when the module is working in Energy Regenerating mode.

5. Power Bus supplying power to the Drive modules through metal bars.

6. Connectors for the inductance needed on XPS models.

7. Lamps indicating the status of the Auxiliary Power Supply and reset button.

"RESET" initializes the Auxiliary 24 Vdc Power Supply after an overvoltage error.

“OVER VOLTAGE” indicates an overvoltage error at the 24 Vdc output.

“OVER CURRENT” indicates and overcurrent error at the 24 Vdc output.

“ON”, it comes on when the 24 Vdc is available.

X1 Connector intermodular communications. Internal Bus.

X2 Connector providing access to the basic control signals.

X3 Input connector supplying to the internal Auxiliary Power Supply from Mains.

X4, X5 and X6 Output connectors of the Auxiliary Power Supply offering 24 Vdc.

Metric mm

Kg·m 2

Nm

°C

Kw

Conversion table to

÷ 25.4

÷ 0.113

÷ 0.113

x 1.8

+ 32

÷ 0.746

Imperial inch lb·in·sec 2 lb·in

°F

HP

Electronic Modules Ver. 0002 EM - 9

EM - 10 Electronic Modules Ver. 0002

EM.1.3.1

POWER CONNECTORS OF THE POWER SUPPLIES

Terminal strip for connection to Mains.

From Mains

R S T

N

RST phases may be connected in any sequence.

Ready Made Cable

MPC-4x...(mm 2 )

The phases may be connected in any sequence.

The ground connection of the cable shields is made from the vertical plate next to the terminal strip.

L1 L2 L3

Gap between terminals (mm)

Max. tightening torque (Nm)

Maximum Section (mm2)

PS-25A PS-25B XPS-25 PS-65A

XPS-65

8.1

1

4

10,16

1,5

10

12.1

2

16

18.8

7

50

The equipment must be protected with fuses on the three-phase line L1, L2 and

L3 as instructed on the chapter IN.

Terminal strip for the external Ballast Resistor.

The drive is supplied from factory with a wire jumper between terminals "Ri" and "L+". This configures the Power Supply to work with its internal Ballast resistor.

If the internal resistor cannot handle enough power, it could be set up to work with an external resistor. The following diagram shows the configuration for an external resistor.

Gap between terminals (mm)

Max. tightening torque (Nm)

Maximum Section (mm2)

PS-25A

XPS-25

XPS-65

8.1

1

4

PS-25B

PS-65A

10.16

1.5/1.7

10

Configuration for internal resistor

Configuration for external resistor

Ri Re L+ Ri Re L+

C

ONTROL

Electronic Modules Ver. 0002

C

ONTROL

EM - 11

If this jumper between "Ri" and "L+" is eliminated and no external resistor is connected, error

215 or 304 will be issued. In the case of the PS-25B module, the Power bus will not be loaded.

The power supply carries a protection against over-temperatures which triggers error 301 when reaching 105°C (221°F).

The power being dissipated by these resistors depends on the ambient temperature according to the following derating curves.

600

520

Internal Ballast

Power (W)

PS-25A

XPS-25

Internal Ballast

Power (W)

PS-25B

400

280

35 (95) 45 (113) °C (°F)

900

600

35 (95) 45 (113) °C (°F)

Internal Ballast

Power (W)

PS-65A

15 (59) 45 (113) °C (°F)

Regenerative power supplies (XPS) also have a small Ballast Circuit for dissipating energy in case of an emergency. This emergency is issued when there is no connection to Mains and the Ballast circuit activating value is exceeded (see general characteristics table).

The performance of the Ballast resistor of the XPS-65 does not suffer at high temperatures.

Connection terminals for the Power Bus

At the bottom of the module, covered by screwed on lid, there are the connection terminals for the Power Bus. This Bus supplies a DC voltage of about 600 Vdc (when the Mains voltage is

380 Vac) for the drive modules.

Two plates are supplied with each module to join the terminals of the adjacent modules. The fastening torque at these terminals must be between 2.3 and 2.8 Nm.

Fagor Power Supplies have a Soft Start for charging this Power Bus.

The Soft start begins when two necessary and sufficient conditions are met:

· No errors at the modules connected to that Power Supply through the internal bus (X1).

· Presence of the three phases at the input of the Power Supply module.

EM - 12 Electronic Modules Ver. 0002

In the case of the PS-25B power supply, it will be enough to have all three phases of Mains

The start process begins when the "FAULT" lamp stops blinking and it is over, the "DC BUS

ON" lamp comes on.

Before handling these leads, proceed in the following order:

1st Stop the motors.

2nd Disconnect the Mains voltage at the electrical cabinet.

3rd Wait, before handling these leads.

The Power Supply module needs time to decrease the voltage of the Power Bus down to safe values (< 60Vdc). The green "DC BUS

ON" light off does NOT mean that it is safe to handle the Power

Bus. The discharge time is about 4 minutes depending on the number of elements connected.

The Power Buses of different Power Supply Modules MUST NEVER be connected in parallel.

Inductive filter -Choke- connection terminals. (only at XPS)

The XPS-25 and XPS-65 power supplies offer the connection terminals labeled CH1 and CH2 at the bottom of the module for connecting the inductive filter. See attached table.

This inductance is a must to filter the current circulating from the Power Bus to Mains.

Fagor supplies the CHOKE XPS-25 and

CHOKE XPS-65 for this application.

Use cables with the maximum section allowed (16 and 50 mm 2 ) and shorter than 2 meters (6 feet). They do not have to be shielded.

C H O K E

X P S 2 5

C H O K E

X P S 6 5

M a x .

t i g h t e n i n g t o r q u e

M a x i m u m c a b l e s e c t i o n

2 N m

1 6 m m 2

7 N m

5 0 m m 2

The inductance is an absolute must for the operation of a regenerative power supply.

Installing a Filter with an inductance other than the one recommended in the general characteristics table may cause severe damage to the unit.

Electronic Modules Ver. 0002 EM - 13

EM.1.3.2

X1 CONNECTOR, INTERNAL BUS

Interconnects all the elements of the Servo Drive System. All the modules powered with the same Power Supply must be connected to this Bus and it is required to run it. The Bus must not be disconnected while the system is running.

A ribbon cable is provided with each module (Power Supply or Drive) for this connection.

When using two Power Supply modules within the same Servo system, each group must carry its own internal Bus.

EM.1.3.3

X2 CONNECTOR, CONTROL

This connector is used to control the power supply module.

The internal circuits of the nonregenerative Power Supplies PS-xxA require an external 24 Vdc supply. That's why their X2 connector has three more terminals. An 1.25 Amp fuse protects the internal circuits.

X2

1

7

(Phoenix,

5.08mm)

1

2

3

4

5

6

7

PS-25B

XPS-25

XPS-65

X2

Error Reset

GND

System

Speed Enable

System O. K.

X2

1

(Phoenix,

5.08mm)

10

PS-25A

PS-65A

1

2

3

4

5

6

7

8

9

10

X2

Error Reset

GND

System

Speed Enable

System O. K.

0 Vdc

+24 Vdc

3

4

5

6

7

1

2

8

9

10

Error Reset

Not connected

GND

Not connected

System Speed Enable

System Ok

System Ok

CHASSIS

0 Vdc

+24 Vdc

System Error Reset Input (24 Vdc) (4.5 - 7 mA)

0 Volts Reference for digital inputs

Error Reset (1) and System Speed Enable (5)

General System Speed Enable (24 Vdc (4.5 - 7 mA))

Contact indicating module estatus

(Opens when fault) Limit: 1 Amp at 24 Vdc

Chassis connection (only on PS-xxA models)

Voltage for Control circuits (only on PS-xxA models) between 21 and 28 Vdc (maximum consumption: 1 Amp)

EM - 14 Electronic Modules Ver. 0002

Procedure to turn on the Power Supply module:

1. At the PS-xxA models.

Supply 24 Vdc to the control circuits of the module through connector X2 (pins 9 and 10).

1. At the XPS and PS-25B.

Apply power to the Auxiliary Power Supply from Mains through connector X3 (pins 2 and

3). These will power the control circuits of the module and provide 24 Vdc at connectors

X4, X5 and X6.

2. The Power Supply module will check the system status.

If not OK, it will turn on the red "FAULT" lamp.

If the status is OK, the "System OK" contact will close (pins 6 and 7).

This contact will stay closed while the control circuits stay under power and while no errors come up at any of the system modules.

3. Apply power to the Power Supply from Mains through the power connectors on top of the module. The soft start will begin and the red "FAULT" lamp will turn off.

4. After 4 seconds, the green “DC BUS ON” lamp will turn on indicating that the DC voltage is now available at the "Power Bus".

If an error occurs at the Power Supply module or at any Drive module it supplies to, the system will act as follows:

The green “DC BUS ON” light will go off.

The red "FAULT" light will stay on if the error is at the power supply.

The "FAULT" light will blink if the error is at some drive.

It will eliminate the voltage supply to the Power Bus (it does not eliminate the capacitors' charge).

With the Error Reset input (pin 1), it is possible to eliminate the errors at the drives constituting the system (See appendix B, resettable errors) and it acts as follows:

It will normally be at 0V. When activated (24V), the errors existing in the memory of each one of the system modules will be deleted.

If the cause of the error persists, the corresponding module will show it again. If the error is serious, it can only be eliminated by powering the unit down and back up.

The System Speed Enable input (pin 5) is related to the "Speed Enable" input of the drive modules.

"System Speed Enable", must normally be at 24 Vdc.

If the "System Speed Enable" pin is set to 0 Vdc, all servo drives connected to the power supply through the same internal Bus will brake their motors at maximum torque and once stopped or the limit time (programmable by parameter GP3) has elapsed, the motor torque is removed.

The consumption of each input is between 4.5 and 7 mA.

Electronic Modules Ver. 0002 EM - 15

EM.1.3.4

CONNECTORS X3, X4, X5, X6 (XPS AND PS-25B)

All four connectors belong to the Auxiliary Power Supply.

X3 receives power from Mains. It admits between 380 Vac and 460 Vac.

This power supply generates 24 Vdc to feed the control circuits of the module itself.

Also, up to 8 Amps of dc voltage are supplied through X4, X5 and X6 . These three connectors are identical and offer greater connecting flexibility.

1

3

(Phoenix,

7.62 mm)

1

3

(Phoenix,

5.08 mm)

X4 X5 X6

1

2

3

1

2

3

PS-25B

XPS-25

XPS-65

X3

380 - 460 Vac

+24 Vdc

0 Vdc

Very important:

In case of micro-surges or total loss of Mains power, this module guarantees stable and maintained 24 Vdc while the emergency braking of the motor. This is a MUST for the machine to comply with the CE seal.

EM - 16 Electronic Modules Ver. 0002

EM.2

MODULAR DRIVE (AXES AND SPINDLE)

There are modular drives specific for controlling axes (synchronous motors) and the spindle

(asynchronous motors).

This chapter is common to both models because their external characteristics: dimensions, connectors, etc. are the same.

EM.2.1

GENERAL CHARACTERISTICS, MODULAR DRIVES

EM.2.1.1

AXIS AND SPINDLE DRIVES

Rated current (Amp)

Maximum peak current (500ms) in cycles longer than 10 seconds

Imax

AXD

1.08

4

AXD

1.15

Axis Drive (Synchronous Motors)

AXD

1.25

AXD

1.35

AXD

2.50

AXD

2.75

AXD

3.100

AXD

3.150

7,5 12,5 17.5

25 37,5 50 75

8 15 25 35 50 75 100 150

Power voltage input

Power to control circuits

Consumption of these circuits (24Vdc)

Speed feedback

Controling method

Communication

Interface

Status display

Protections

Speed range with analog input

Current bandwidth

Speed bandwidth

Ambient temperature

Storage temperature

Sealing grade

Maximum humidity

Weight kg (lbs)

456 - 800 Vdc

24 Vdc (between 21Vdc and 28 Vdc)

0.9 Amps 1.25 Amps

Encoder / Resolver

PWM, sinewave AC, Vector Control

Serial line

2 Amps

Standard analog or digital via Sercos

7 - segment display

Over-voltage, Overcurrent, overspeed, heat sink temperature, ambient temperature, motor temperature, hardware error, overload, etc. See appendix E.

1:8192

800 Hz

100 Hz (Depends on the motor/drive set)

5°C / 45°C. (41°F / 113°F)

From 40°C (104°F) on, see Derating tables

-20°C / +60°C (-4°F / +140°F)

IP2x

Less than 95% (non condensing at 45°C / 113°F)

6 (13.3) 10 (22.2) 18,5 (41.1)

5,6

SPD

1.08

10,6 19,6 28.5

35,4 53 80 106

SPD

1.15

SPD

1.25

SPD

1.35

SPD

2.50

SPD

2.75

SPD

3.100

Spindle Drive (Asynchronous Motors)

SPD

3.150

Electronic Modules Ver. 0002 EM - 17

EM.2.2

DERATING OF THE MODULAR DRIVES

The following graphs show the maximum rms current in continuous duty cycle that the various

Drive modules can provide depending on ambient temperature.

Axis drives:

For a maximum time period of 0.5 seconds, and always in cycles longer than 10 seconds, they may output twice the current.

The AXD 1.08 and AXD 1.15 models, maintain their best characteristics, indicated in the previous table, throughout the full temperature range, between 5 and 55°C (41 ºF and 131 ºF).

12.5

12

10.2

Current

S1 (Amp)

AXD 1.25

17.5

17

Current

S1 (Amp)

AXD 1.35

25

22

35 (95) 40 (104) 55 (131) °C (°F)

Current

S1 (Amp)

AXD 2.50

37.5

29.5

25

Current

S1 (Amp)

50 (122) 55 (131) °C (°F)

AXD 2.75

50

45

Current

S1 (Amp)

40 (104) 55 (131) °C (°F)

AXD 3.100

75

68.5

20 (68) 40 (104) 55 (131) °C (°F)

Current

S1 (Amp)

AXD 3.150

45 (113) 55 (131) °C (°F) 45 (113) 55 (131) °C (°F)

EM - 18 Electronic Modules Ver. 0002

Spindle drives:

The drive can output the indicated current in any duty cycle.

Models SPD 1.08, SPD 1.15, SPD 1.25, SPD 2.50 and SPD 3.100, maintain their best characteristics, indicated in the previous table, throughout the full temperature range, between

5 and 55°C (41ºF and 131 ºF).

53

43

Current

S1 (Amp)

SPD 2.75

35 (95) 55 (131) °C (°F)

28.5

27.6

Current

S1 (Amp)

SPD 1.35

106

92

Current

S1 (Amp)

50 (122) 55 (131) °C (°F)

SPD 3.150

40 (104) 55 (131) °C (°F)

Electronic Modules Ver. 0002 EM - 19

EM.2.3

CONNECTORS OF THE MODULAR DRIVE

The next figure shows the elements appearing on the front plate of the modular drive:

1) Power connectors for motor connection.

2) 2.5 Amp (F) / 250V Fast fuse.

To protect the internal control circuits.

3) Sercos Interface connectors.

4) Status Display. Shows status information for the drive itself or the relevant code when there is an error.

5) Power connectors at the bottom to power the Drive module.

X1) Connector for module interconnection through the internal BUS.

A connector is supplied with each module for connecting it to the BUS. This connection is described in detail in the section corresponding to the power supply.

If during system setup or maintenance, any module is constantly generating an error, the whole system is completely disabled. To temporarily ignore this error, disconnect the internal bus of that module and keep the other ones connected.

X2) Connector for the basic control signals.

X3) Connector with two possible uses:

- as output of the Encoder simulator.

- as input of a second feedback for the position loop.

X4) Motor speed feedback connector.

X5) Serial line connector.

SL1)

SL2)

Slot for cards: A1, 16DI-8DO and 8DI-16DO.

Slot for cards: 16DI-8DO and 8DI-16DO.

EM - 20 Electronic Modules Ver. 0002

EM.2.3.1

POWER CONNECTORS

The upper connectors are for connecting the motor.

The ground connection of the cable shields is made from the vertical plate next to the connectors.

The bottom connectors correspond to the power bus input. The drive needs

456-800Vdc which can vary depending on the Mains voltage and the load. The power supply module is in charge supplying this voltage.

2 plates are supplied with each module for this connection and another one for connecting the chassis with each other.

Gap between terminals (mm)

Max. tightening torque (Nm)

Maximum Section (mm2)

AXD/SPD AXD/SPD AXD/SPD AXD2 AXD3.100 AXD3.150

1.08/15 1.25

1.35

SPD2 SPD3.100 SPD3.150

7.5

0.6

2.5

7.5

0.6

4

8.1

1

4

10.1

1.7

10

15.1

7

25

18.8

7

50

When connecting the drive module and its corresponding motor, connect terminal "U" of the drive module with the terminal corresponding to the

"U" phase of the motor as well as terminals "V-V", "W-W" and "Ground-

Ground".

Otherwise, it might not perform properly.

The cable must have a metal shield which must be connected to the ground terminal of the drive and NOT to that of the motor in order to comply with EEC directives.

Before handling these terminals, proceed as follows:

1st Disconnect the Mains voltage at the electrical cabinet.

2nd Wait, before handling these terminals

The power supply module takes about 4 minutes (depending on the number of elements connected) to bring the power bus voltage down to safe values (< 60Vdc). The green “DC BUS ON” light off does NOT mean that we can handle the power bus.

Electronic Modules Ver. 0002 EM - 21

EM.3

COMPACT DRIVE (AXES AND SPINDLE)

The Fagor Compact Drive has its own power supply and it can be connected directly to Mains.

Its behavior, functionality and parameters are the same as those of the Modular Drive.

EM.3.1

GENERAL CHARACTERISTICS

See the table on the next page,

EM.3.2

DERATING, COMPACT DRIVES

The following graphs show the maximum rms current in continuous duty cycle offered by the various compact drives depending on ambient temperature.

Fagor ACD 2.75 compact drives for synchronous motors offer an rms current of up to 34.7

Amps and Fagor SCD 2.75 compact drives for asynchronous motors 53 Amps.

Models ACD 1.08, SCD 1.08, SCD 1.15, SCD 1.25 and SCD 2.50, maintain their best characteristics, indicated in the previous table, in the full range of temperatures between 5 °C and 55 °C (between 41 °F and 131 °F).

Axis Compact Drives:

They can supply twice as much current for a maximum of 0.5 seconds and always in cycles longer than 10 seconds.

Spindle Compact Drives:

The compact drive can supply the indicated current in any duty cycle.

Current

S1 (Amp)

ACD 1.15

7.5

6.7

45 (113) 55 (131) °C (°F)

12.5

11.4

Current

S1 (Amp)

ACD 1.25

45 (113) 55 (131) °C (°F)

25

24

Current

S1 (Amp)

ACD 2.50

50 (122) 55 (131) °C (°F)

34.7

31.3

27.8

Current

S1 (Amp)

ACD 2.75

35 (95) 45 (113) 55 (131) °C (°F)

53

47.9

Current

S1 (Amp)

SCD 2.75

45 (113) 55 (131) °C (°F)

EM - 22 Electronic Modules Ver. 0002

Rated current (Amp)

Maximum peak current for 500ms in cycles longer than 10 seconds.

Maximum current in any duty (Note 3)

Power supply

Internal power bus voltage.

Filter capacity

Energy stored in the capacitors.

Internal Ballast resistor

-Ohms- (Power -W-)

Energy pulse that can be dissipated. -kWs-

(Pulse duration -sec-)

Ballast circuit ON/OFF

Minimum external Ballast Res. -Ohms-

Feedback

Control method

Communications

Interface

Status display

Speed range with analog input

Current bandwidth

Velocity bandwidth

Protections

ACD

1.08

Axis Compact Drive

(Note 1)

ACD

1.15

ACD

1.25

ACD

2.50

ACD

2.75

4 7,5 12,5 25 37,5

Spindle Compact Drive

(Note 2)

SCD

1.08

SCD

1.15

SCD

1.25

SCD

2.50

SCD

2.75

8 15 25 50 75

330

82

(60)

1

(0.45)

5,6 10,6 17,7 35,4

Three-phase mains 50/60 Hz, with a voltage range between 380Vac -15%. and 460Vac + 10%

µ

F, 800 Vdc

41

(120)

2

(0.4)

23

(210)

3.6

(0.45)

12

(240)

12

(0.7)

540-650- Vdc

705

µ

F,

800 Vdc

330

µ

F, 800 Vdc

0.5 · C · V 2

8.2

(240)

12

(0.5)

82

(60)

1

(0.45)

764 Vdc / 756 Vdc

41

(120)

2

(0.4)

23

(210)

3.6

(0.45)

705

800 Vdc

12

(240)

12

(0.7)

µ

53

F,

8.2

(240)

12

(0.5)

82 41 23 12 8.2

82 41 23 12 8.2

Encoder /Resolver Encoder

PWM, sinewave AC, Vector Control

Serial line to connect to a PC or to the Programming Module

Standard analog, or digital via SERCOS

7 - segment display

1:8192

800 Hz

100 Hz (Depends on the motor/drive combination)

Overvoltage, Overcurrent, overspeed, heat-sink temperature, ambient temperature, motor temperature, Ballast temperature, Hardware error, overload.

See appendix E.

Notes:

1.- Drives for synchronous motors 2.- Drives for asynchronous motors

3.- This current must be equal to or greater than that of the corresponding spindle motor in S6.

Power for Internal circuits (24 Vdc)

Input voltage (X1 connector)

Mains consumption

Bus consumption

Maximum voltage at the Bus

Output voltage, maximum current

Between 380Vac (-15%) and 460Vac (+10%); 50/60Hz

160 mA (380 Vac), 130 mA (460 Vac)

112 mA (540 Vdc), 92 mA (650 Vdc)

780 Vdc

24 Vdc (5%), 110 miliAmp. (X2 connector, pins 1 and 2)

Ambient conditions

Ambient temperature

Storage temperature

Maximum humidity

Vibration while running

Vibration while shipping

Sealing

Weight. Kg (lbs)

5°C / 45°C. (41°F / 113°F)

From 40°C (104°F) See Derating tables

-20°C / +60°C (-4°F / +140°F)

Less than 95% (non condensing at 45°C / 113°F)

10..60 Hz, 0.1..5 G, 2 hr

8.3 (18.4)

60..300 Hz, 5 G, 2 hr

IP2x

13.2 (29.3) 8.3 (18.4) 13.2 (29.3)

Electronic Modules Ver. 0002 EM - 23

EM.3.3

CONNECTORS OF THE COMPACT DRIVE

The next diagram shows the elements appearing on the front plate of the Compact Drive:

1) Power connectors for motor and mains connection. Access to the power bus.

2) Fuses to protect the internal control circuit.

Two 1 Amp (T) / 500V slow fuses on the power supply lines.

3) Sercos Interface connectors.

4) Status Display. Shows the status information of the drive itself or the corresponding error code.

5) Compact Drive Status Leds. Activation of the Ballast circuit, presence of power at the

Bus and 24 Vdc available.

X1) Connector for the internal 24 Vdc power supply (two-phase 380-460 Vac).

X2) Connector for the basic control signals.

X3) Connector with two possible uses:

- as output of the Encoder simulator.

- as input of the second feedback for the position loop.

X4) Connector for the motor speed feedback. Encoder or Resolver.

X5) Serial line connector

SL1) Slot for cards: A1, 16DI-8DO and 8DI-16DO.

SL2) Slot for cards: 16DI-8DO and 8DI-16DO.

DDS PROG MODULE) Accessory for adjusting and monitoring the system, it can be mounted into the compact drive. Available upon request.

EM - 24 Electronic Modules Ver. 0002

EM.3.3.1

POWER CONNECTORS

They are used for connecting the compact drive to mains (L1, L2, L3) and to the motor (U, V, W). They also have the necessary terminals for connecting an external Ballast resistor.

For the ACD1... and SCD1... type drives, this same upper connector gives access to the Power Bus (L+, L-).

The ground connection of the cable shields is made from the vertical plate next to these connectors.

The ACD2... and SCD2... provide the Bus via the lower connector like modular drives.

2 plates are provided with each module to make this connection and another one for connecting the chassis to each other.

Gap between terminals (mm)

Max. tightening torque (Nm)

Maximum Section (mm2)

ACD1

SCD1

8.1

1

4

ACD2

SCD2 power

12.1

2

16

ACD2

SCD2 ballast

10.16

1.6

10

The equipment must be protected with fuses on the three-phase supply lines L1, L2 and L3.

Follow the instructions on the installation chapter (IN).

When connecting an external Ballast Resistor to the Compact Module, check that the ohmage of the resistor is equal to than that of the internal

Ballast Resistor. See the characteristics table and the IN chapter of the installation manual. Therefore, the RM-15 MUST NOT be used with the

Compact drives.

When connecting the drive module with its corresponding motor, connect

Terminal "U" of the drive module with the corresponding "U" phase of the motor, same as terminals "V-V", "W-W" and "Ground-Ground".

Otherwise, it will not run properly. The cable hose must have a metallic shield which must be connected to the drive's ground terminal and not to that of the motor in order to comply with CE directives.

Electronic Modules Ver. 0002 EM - 25

Before handling these terminals proceed as follows:

1st Disconnect the Mains voltage at the electrical cabinet.

2nd Wait before handling these terminals

The module needs time to bring the voltage at the power bus down to safe values (< 60Vdc). The fact that the green “DC BUS ON” light is off does not mean that it is safe to handle the power bus.

The discharge time depends on the number of elements connected to this

Bus and it is approximately 4 minutes..

Terminals Ri, Re, L+ are used for configuring the Ballast circuit which dissipates the energy generated when braking the motors.

By short-circuiting the terminals (Ri, L+), the system is configured so as to work with the internal resistor of the compact drive module. Up to 45 °C (113 °F), this internal resistor dissipates the power indicated in the previous characteristics table. It also incorporates a protection against overtemperature which issues an error 301 when reaching

105 °C (221 °F).

By removing this jumper (Ri, L+) an external resistor may be connected between Re and L+ which will then dissipate the energy.

See the drawing on the next page.

The following graphs show the power derating of the compact drives:

80

60

Internal

Ballast

Power (W)

ACD/SCD 1.08

160

120

Internal

Ballast

Power (W)

ACD/SCD 1.15

15 (59)

267

200

Internal

Ballast

Power (W)

45 (113) °C (°F)

ACD/SCD 1.25

15 (59) 45 (113) °C (°F)

320

240

Internal

Ballast

Power (W)

ACD/SCD 2.50

ACD/SCD 2.75

15 (59) 45 (113) °C (°F) 15 (59) 45 (113) °C (°F)

EM - 26 Electronic Modules Ver. 0002

Configuration for internal resistor

Ri Re L+

Configuration for external resistor

Ri Re L+

C

ONTROL

C

ONTROL

EM.3.3.2

CONNECTOR X1

Compact Drives internally generate the 24Vdc necessary for the internal circuits.

In regular operation, this voltage is obtained from the Power Bus and from mains when starting up the system.

The mains energy necessary for start-up is supplied via this three-prong Phoenix connector.

The start-up process needs an internal module test prior to supplying power to the upper terminals. Therefore, bear in mind the following warning:

Power from this internal power supply, through this connector X1, must be the very first thing to do before any other electrical manoeuvre.

Current from mains phases to these lines L1 and L2 must be obtained from a point before the contactor providing the three-phase power to the upper connectors of the Compact Drive. See sample schematic of an electrical cabinet on chapter IN.

The Module is protected by 1 Amp fuses one per phase.

Electronic Modules Ver. 0002 EM - 27

EM.4

ASPECTS COMMON TO BOTH MODULAR AND COMPACT

EM.4.1

STATUS DISPLAY

During the module start up, in order to check that all the display segments are operating correctly, this display shows the following information:

First, the display is seen completely off, and then it shows numbers 1, 2, 3 and 4 corresponding to the four initializing stages and, then, it will turn back off.

Then, the version of the software used by the module is shown. First, the letter "r" is shown

(indicating the -release- version) followed by the version number (digit by digit).

When the drive is active and the axis is being governed, the display will show a zero with a blinking dot. While loading parameters, the display only shows the middle segment.

Lastly, if there are any error messages or warnings, the display shows them as indicated by these two examples. The period resets the error and warning display.

Error "501" has occurred.

Error "300", and warning "1".

See Appendix B for the meanings of errors and warnings

The system will not start running until all the errors detected at the drive have been eliminated.

To eliminate these errors, their cause has to have disappeared and, then, an "Error Reset" must be carried out. This Reset may be carried out via X2(1) of the power supply module, or pin X2(3) of the Compact Drive.

There are errors indicated as "Non-resettable" in appendix B and they cannot be removed by this method. Those non-resettable errors can only be removed by turning the unit off and back on provided their cause has been previously eliminated.

EM - 28 Electronic Modules Ver. 0002

EM.4.2

SERCOS CONNECTION

The IEC 1491 SERCOS interface is an international standard for digital communications between CNCs and servo drives of CNC machines.

The Sercos communications ring integrates several functions.

It carries the velocity command from the CNC to the drive in digital format with greater accuracy and immunity against outside disturbances. It carries the feedback signal from the

Drive to the CNC. It communicates the errors and manages the basic control signals of the

Drive (Enables). It allows setting, monitoring and diagnosis of the parameters from the CNC with simple and standard procedures.

All this drastically reduces the hardware required at the Drive, thus, making it more reliable.

Its open and standard structure provides compatibility between CNCs and servo systems from different manufacturers on the same machine.

Electronic Modules Ver. 0002 EM - 29

EM.4.3

CONNECTOR X2, CONTROL

Modular drive:

When the control circuit is supplied with 24 Vdc (pins 7 and 8) the drive runs an internal test. If the system is OK, it closes the module status contacts (pins 4 and 5 "Drive OK). This contact stays closed while the drive is supplied with 24 Vdc and it runs properly. To govern a motor, the drives also needs energy at the Power Bus.

The maximum internal consumption of the 24 Vdc supply input is 2 Amp for the bigger

Drives. The internal circuits are protected by a 2.5Amp fuse.

See the characteristics table of the previous sections.

With the “Drive Enable” and “Speed Enable” inputs (pins 2 and 3) together with the velocity command, it is possible to govern the motor. The consumption of these control signals is between 4.5 and 7 mA. A later graph shows the behavior of the Drive depending on the “Drive

Enable” and “Speed Enable” inputs

EM - 30

1

4

5

2

3

6

7

8

GND

Drive Enable

Speed Enable

Drive Ok

Drive Ok

CHASSIS

0 Vdc (in)

+ 24 Vdc (in)

Control signals

Supply input for the control circuit.

Reference "0V" for control signals.

Through-the-motor current enable (24Vdc)

Drive Speed Enable (24Vdc)

Module status contact (it opens in case of failure)

Limit: 1 Amp at 24 Vdc.

Chassis connection.

Reference "0V".

Positive voltage input (21 Vdc ... 28 Vdc).

Electronic Modules Ver. 0002

Compact Drive

Integrates specific functions of the Power Supply and modular Drives.

Specific of the Power Supply: With the Error Reset input (pin 3), it is possible to remove the errors at the compact drive (see appendix D, resettable errors). When activated, (24V) those errors are eliminated. If the cause of the error persists, the "status display" will show the error again. But if it is a major error, it can only be eliminated by powering the unit off and back on. Pins 1 and 2 offer a 24 Vdc output for the user. The maximum output current is 100 mA.

Specific of the modular Drive: control signals. The “Drive Enable” and “Speed Enable” inputs

(pins 4 and 5) together with the velocity command govern the motor. The consumption of these control signals is between 4.5 and 7 mA. The following page describes the behavior of the drive depending on these control signals.

The “Drive OK” contact (pins 6 and 7) will stay closed as long as the compact drive runs properly.

New: The “Prog Out” contact (pins 8 and 9) is a user programmable output by means of the drive's internal parameter OP5 -F00291-. Its value may be forced with variable

OV5 -F00292-.

Electronic Modules Ver. 0002

1

2

7

8

9

10

5

6

3

4

+ 24 Vdc (out)

0 Vdc (out)

Error Reset

Drive Enable

Speed Enable

Drive Ok

Drive Ok

Prog Out

Prog Out

CHASSIS

Internal

Power

Supply output

Positive Voltage Output. (24 Vdc, 100 mA)

"0 V" Reference.

System Error Reset input. (24Vdc) (4.5-7mA)

Motor current enable. (24Vdc)

Control

Signals

Drive Speed Enable. (24Vdc)

Module Status Contact (it opens in case of failure)

Limit: 1 Amp at 24 Vdc.

Programmable internal contact Limit: 1 Amp at 24 Vdc.

Chassis connection.

EM - 31

EM.4.3.1

SPEED ENABLE, DRIVE ENABLE

Normal operation mode.

1. Activate inputs “Drive Enable” and “Speed Enable”

They may be activated in any order. Before doing so, the "Soft Start" process (smoothly reaching the power bus voltage) must be over. The torque at the motor will only be available when Drive_Enable is active and there is voltage at the Power Bus. The motor speed will be controlled by a velocity command when Speed_Enable function is active.

Attention: For activating the Speed_Enable function, the system MUST request it in three different ways: electrical signal at connector X2, variable BV7 -F00203- and variable

DRENA of the PLC when using the Sercos interface. It could be deactivated through any of them.

2. The motor will respond to all analog command variations only while both inputs (“Drive

Enable” and “Speed Enable”) are at 24 Vdc. If any of them is deactivated, the following will happen:

EM - 32

GP3

No torque

No torque

Proper braking < GP3 time

Braking time < GP3 time time

With to rque

Braking time > GP3

Trigger Error-4

No torque time tiempo tiempo time time time

Electronic Modules Ver. 0002

Deactivation of the Drive Enable input

The “Drive Enable” input (pin 2) controls the Current Loop by hardware.

When it is powered with 24 Vdc, the Current Loop is enabled and the drive can work.

If the "Drive Enable" input is set to 0 Vdc, the power circuit turns off and the motor loses its torque. In this situation the motor is no longer governed and will turn freely “stopping by friction”.

Deactivation of the "Speed Enable" function

When Speed_Enable is set to 0 Vdc, the "internal velocity command" switches to 0 rpm and:

Case 1: The Torque is kept active by braking the motor. When it stops, variable

SV5 -S00331- is activated. The motor has stopped in a time period shorter than the one indicated by parameter GP3 -F00702-. The torque is canceled and the rotor is free.

Case 2: The Torque is kept active by braking the motor. The motor does not stop in a time period shorter than the one indicated by parameter GP3 -F00702-. Error-4 is issued, the torque is canceled and the rotor is free. The motor stops when its inertia runs out

(by friction).

GP3 and SV5 -S00331- are internal parameters and may be consulted in Appendix A.

Safety standards (EN-60204-1) require the drive module to have a software independent input in order to always assure that the motor will stop.

The "Drive Enable" input, using only hardware, can cancel the Power

Circuit leaving it deactivated.. This allows stopping even when the software fails.

In case of mains failure, the control circuit and its signals must maintain their 24 Vdc while the motors are braking.

On the Modular Drive, the 24 Vdc for supply and "Drive_Enable" activation must be provided by a power supply that can maintain it during that time.

The Power Supply PS-25B, the Auxiliary Power Supply APS 24 and the

Regenerative Power Supplies XPS meet this condition.

In the case of the Compact Drive, the 24 Vdc at pins 1 and 2 meets this requirement and are appropriate for managing the control signals.

Electronic Modules Ver. 0002 EM - 33

EM.4.4

CONNECTOR X3

This connector offers two possible configurations:

- encoder simulator

- second feedback

EM.4.4.1

X3, ENCODER SIMULATOR

For the simulator, X3 is a high density 15-pin SUB-D type male connector whose pins are galvanically isolated from the rest of the drive.

It outputs square differential TTL pulses simulating those of an encoder that would be mounted on the motor shaft.

The number of pulses per turn and the position of the reference mark "I

0

" are programmable.

The parameter that set up the characteristics of this simulated encoder are:

EP1 -F00500-, EP2 -F00501-, EP3 -F00502- and EC1 -F00503-.

The setting procedure is described in the SSU chapter and the parameters in appendix A.

The connection cable for this encoder simulator is supplied with the name of SEC and it comes with a length of up to 25 meters.

90° PHASE-SHIFT

V

A

V

B

Io t

V

OH

> 2.5 V

V

OL

< 0.5 V

I

SURCE

< 20 mA

I

SINK

< 20 mA

EM - 34 Electronic Modules Ver. 0002

EM.4.4.2

X3, DIRECT FEEDBACK

For direct feedback, X3 is a high density 15-pin SUB-D type female connector

This connector admits three different types of feedback signals (see diagram below):

- Square TTL signals

- Square differential TTL signals (double-ended)

- 1Vpp sinewave signals

It admits the following frequencies:

- 1 MHz with square signals

- 200 KHz with sinewave signals.

The input impedance for sinewave signals is 120 Ohms.

Software involved:

Parameters AP1 -S32-, GP10 -F719-, PP115 -S115- and NP117 -S117- identify different aspects of the direct feedback. The gear ratio between the motor and the ballscrew is indicated by NP121 -S121-, NP122 -S122- and NP123 -S123-.

90° PHASE-SHIFT

V

A

V

B

I

0

V

A

V

B

I

0

90° PHASE-SHIFT t

V

OH

> 2.5 V

V

OL

< 0.5 V t

V

A

, V

B

: 0.6 - 1.2 Vpp

V

I0

: 0.5 Vpp

Electronic Modules Ver. 0002 EM - 35

EM.4.5

CONNECTOR X4, FEEDBACK

Connector X4 receives the signals coming from the feedback at the motor shaft.

The feedback on Fagor motors may be through a sinusoidal encoder or a resolver. In either case, the signals must be taken to different pins using the connection cables EEC and REC respectively.

Fagor supplies these cables with lengths of up to 25 meters.

X4 is high density 26-pin Sub-D type female connector.

General parameter GP2 -F00701- determines the type of sensor that the rotor has. The parameter group "R" sets the features of the sensor.

EM - 36 Electronic Modules Ver. 0002

EM.4.6

CONNECTOR X5, SERIAL LINE

To set the configuration parameters and adjust the Drive module, it must be connected to a

PC, or the Programming Module "DDS PROG MODULE".

This connection is made via connector X5.

It is a 9-pin Sub-D type male connector for serial line communications.

It also offers the 5Vdc supply for the Programming Module.

1

2

3

4

R x D

T x D

+ 5 V

N

R

T r

S o u t e c a n c p p o n e i s m l y n e v e i t o d d u c t a t a t p t e d a a u t

5

6

G N D Z e r o v o l t s R e f e r e n c e

N o t c o n n e c t e d

R e s e r v e d * 7

8

9

N o t

R e c s o n e r n e v e c t d * e d

C h a s s i s C h a s s i s C a b l e s h i e l d

* R e s e r v e d p i n s m u s n ' t b e c o n n e c t e d t o a n y t h i n g .

Electronic Modules Ver. 0002 EM - 37

EM.4.7

CONNECTORS AT SL1 AND SL2

EM.4.7.1

A1 card

The A1 card must always be in SL1.

X6, digital inputs and outputs

It offers four digital inputs and four digital outputs, all of them fully programmable.

The digital inputs are optocoupled and referred to a common point (pin 5).

The digital outputs are contact type and also optocoupled.

Each input and output is associated with a parameter as shown in the diagram.

The operator may assign internal boolean type variables to these parameters (for example:

SV3 -S00332-, SV5 -S00331-, TV10 -S00333-, etc.) in order to indicate the system status through electrical contacts. These variables are set by means of the monitoring program for

PC or through the DDS PROG MODULE.

(A1 Board)

1

(Phoenix,

3.5 mm)

1

13

1

A1

Pin

1

2

8

9

10

11

12

13

3

4

5

6

7

IN 1

IN 2

IN 3

IN 4

REF-IN

(IP10 -F00901-)

(IP11 -F00902-)

(IP12 -F00903-)

(IP13 -F00904-)

OUT 1 (OP10 -F01404-)

OUT 2 (OP11 -F01405-)

OUT 3 (OP12 -F01406-)

OUT 4 (OP13 -F01407-)

EM - 38

Digital Inputs Characteristics:

Nominal voltage (maximum) 24 Vdc (36 Vdc)

Turn-on/off Input voltage

Typical consumption (maximum)

18 Vdc / 5 Vdc

5 mA (7 mA)

Digital Outputs Characteristics:

Maximum voltage 250 Volts

Maximum load current (peak)

Maximum internal resistance

Galvanic isolation voltage

150 mA (500 mA)

24 Ohms

3750 Volts (1 min)

Electronic Modules Ver. 0002

X7, analog inputs and outputs

It offers two inputs and two outputs, all of them fully programmable.

Each input and output is associated with certain parameters as indicated in the drawing.

It offers a ±15V power supply for easily generating the command.

(Phoenix,

3.5 mm)

1

P2

P1

(A1 Board)

1

1

A1

IV2

-F00906-

IP1

-F00900-

IV1

-F00905-

-15Vdc

+15Vdc

OP2 -F01401-

OP4 -F01403-

OP1 -F01400-

OP3 -F01402-

Pin

4

5

6

7

8

9

1

2

3

10

11

Chassis

Analog Input 2 (-)

Analog Input 2 (+)

Analog Input 1 (-)

Analog Input 1 (+)

-15Vdc

+15Vdc

OUT2 (-)

OUT2 (+)

OUT1 (-)

OUT1 (+)

11

3

4

1

2

5

6

7

8

9

10

11

Chassis

Analog input 2 (-)

Analog input 2 (+)

Analog input 1 (-)

Analog input 1 (+)

- 15Vdc output for adjustment (User)

+15Vdc output for adjustment (User)

Reference for Analog output 2 (-)

Analog output 2 (+)

Reference for Analog output 1 (-)

Analog output 1 (+)

Electronic Modules Ver. 0002 EM - 39

Analog input 1 (pins 4 and 5)

It is the usual input for the velocity command (±10Vdc) generated by the CNC.

The initial offset adjustment is made through parameter SP30 -F01603-.

Later adjustments may be made with potentiometer P1.

Analog input 2 (pins 2 and 3)

This is an input for an auxiliary command.

The initial offset adjustment is made through parameter SP31 -F01604-.

Later adjustments may be made with potentiometer P2.

Variables IV1 -F00905- AnalogInput1 and IV2 -F00906- AnalogInput2 register the value of these analog inputs at all times. Parameter IP1 -F00900- selects which of these inputs is considered by the drive as its velocity command.

Parameter SP20 -F00031- and SP21 -F00081- set the relationship between the voltage applied at the input and the velocity command it corresponds to. See chapter SSU.

Analog Inputs Characteristics:

Resolution

Input voltage range

Continuous mode

Input Overvoltage

Transients

With respect to GND

Input Impedance

Between both inputs

Voltage in common mode

1.22 mV

±10 Vdc

80 Vdc

250 Vdc

40 KOhms

80 KOhms

20 Vdc

EM - 40 Electronic Modules Ver. 0002

Dip-Switches.

The status of the Dip-Switch (DS1, DS2) MUST NOT be changed by the operator.

Adjustment outputs (pins 6 and 7)

With these outputs and a potentiometer, the user can obtain a variable analog voltage for adjusting the servo system during setup. The voltage, with no load, at these pins is ±15

Vdc.

The figure below shows the electrical circuit necessary to obtain the reference voltage.

The table next to it shows the resistor values recommended for a Vref voltage range of about ±10 Vdc.

±10 Volt Range

Rext => R'

1 KOhms => 0 Ohms

5 KOhms

10 KOhms

=>

=>

820 Ohms

1.8 KOhms

20 KOhms => 3.3 KOhms

Vref

R'

Rext

R'

GND

X7

1

4

5

DRIVE

6

-15 Vdc

7

8

10

+15 Vdc

Analog outputs (pins 8-9 and 10-11)

These outputs provide the status of the two internal system variables with an analog value. They are especially designed to be connected to an oscilloscope and facilitate system setup or to continuously monitor those internal variables.

Note: If the output current is high, the voltage range may decrease.

The parameters controlling these analog outputs are OP1 -F01400-, OP2 -F01401-,

OP3 -F01402- and OP4 -F01403-. The internal variables (speed reference, Actual speed, torque, etc.) that can be associated with each one of the outputs are set by means of the monitor program for PC-Windows supplied by Fagor: "DDS-SETUP". See chapter SSU.

Analog Outputs Characteristics

Resolution 4.88 mV

Voltage range

Maximum current

Impedance (respect to GND)

±10 Vdc

±15 mA

112 Ohms

Electronic Modules Ver. 0002 EM - 41

EM.4.7.2

Cards 8DI-16DO and 16DI-8DO

These cards may be located in SL1 and/or SL2.

• 8I-16O offers to the user eight digital inputs and sixteen outputs.

• 16I-8O offers to the user sixteen digital inputs and eight outputs.

X8, X11, X12, digital inputs

They offer eight fully programmable digital inputs.

The digital inputs are optocoupled and referred to a common point (pin 1) and they admit digital signals at 5 Vdc or at 24 Vdc. The four least significant bits of parameter

IP5 -F00909- DigitalInputsVoltage determine this configuration for the input voltage.

Each input is associated with a PLC resource.

(Phoenix,

3.5 mm)

1

(8DI-16DO Board)

1

(16DI-8DO Board)

1

1

8DI-16D0

1

9

1

16DI-8D0

1

Pin

3

4

5

6

1

2

7

8

9

EM - 42

Digital inputs characteristics.

Configuration:

Rated voltage (maximum)

Turn-on/off Input voltage

Typical consumption (maximum)

5 V

5 Vdc (40 Vdc)

2.6 Vdc / 1.4 Vdc

3 mA (5 mA)

24 V

24 Vdc (40 Vdc)

12 Vdc / 6 Vdc

5 mA (7 mA)

Electronic Modules Ver. 0002

X9, X10, X13, digital outputs.

They offer eight fully programmable digital outputs.

These outputs are optocoupled and of the contact type referred to a common point (pin 1).

Each output is associated with a PLC resource.

(Phoenix,

3.5 mm)

1

(8DI-16DO Board)

1

(16DI-8DO Board)

1

1

8DI-16D0

1

9

1

16DI-8D0

1

Pin

3

4

5

6

7

8

9

1

2

Digital outputs characteristics:

Maximum voltage 250 Volts

Maximum load current

Current selflimitation

150 mA

200 mA

Maximum internal resistance

Galvanic isolation voltage

20 Ohms

3750 Volts (1 min)

Electronic Modules Ver. 0002 EM - 43

EM.4.7.3

Numbering of the PLC resources on the cards

Inserting the cards in slots SL1 and SL2 permits all the possible combinations except for two

A1 type cards.

At the PLC, the input/output resources can be named according to their location in SL1 and/or

SL2:

• The card inserted in slot SL1 numbers the pins from I1 and O1 on.

• The card inserted in slot SL2 numbers the pins from I17 and O17 on.

• The resources are numbered from top to bottom.

Drive Module (example)

SL2 SL1

X11

1

9

1

I25

I27

X12

I29

I31

9

16DI-8DO

1

O17

X13

O19

O21

O23

9

I17

I19

I21

I23

I26

I28

I30

I32

O18

O20

O22

O24

I18

I20

I22

I24

X8

1

I7

9

8DI-16DO

1

O1

I1

I3

I5

X9

O3

O5

O7

9

1

X10

9

I2

I4

I6

I8

O9

O10

O11

O12

O13

O14

O15

O16

O2

O4

O6

O8

1

I17

I19

I21

X8

X9

X10

I23

9

8DI-16DO

1

O17

O19

O21

O23

9

1

O25

O27

O29

O31

9

O18

O20

O22

O24

O26

O28

O30

O32

I18

I20

I22

I24

Drive Module (example)

SL2 SL1

1

X6

13

P2

P1

A1

I1

I3

I2

I4

O1

O2

O3

O4

1

X7

11

EM - 44 Electronic Modules Ver. 0002

EM.4.8

INTERNAL CONFIGURATION

The following graphic is the internal diagram of the drive consisting of four basic blocks which are: Position loop, Velocity loop, Current loop and Rotor Sensor processing.

Electronic Modules Ver. 0002 EM - 45

EM.5

MAINS FILTER, EMK

In order to comply with European Directive 89/336/CE on Electromagnetic Compatibility, a Mains Filter EMK must be mounted between mains and the Drive system (modular or compact).

It softens the conducted disturbances emitted by the Drive (within the levels specified by the

European norm), and it also makes it immune to fast transients or voltage pulses.

Rated voltage

Rated current

Aproximated weight

Rated leaking current

Maximum leaking current

Power loss

EMK 3040 EMK 3120

480 Vac (50/60 Hz)

40 Amps 120 Amps

2.3 Kg (5 lbs) 11 Kg (24.2 lbs)

0.5 mA

27 mA

30 W

0.75 mA

130 mA

45 W

Characteristics of the connection terminals.

Gap between terminals (mm)

Max. tightening torque (Nm)

Maximum Section (mm2)

EMK 3040 EMK 3120

10.1

15.1

1.7

10

7

25

The last section of this chapter describes the mechanical dimensions.

The filter must be placed near the Drive system. IN chapter describes the installation rules that must be strictly followed.

EM - 46 Electronic Modules Ver. 0002

EM.6

CHOKE FOR AN "XPS" POWER SUPPLY

When returning power to Mains, the impedance of Mains for the outgoing current is very low.

Thus, the up ramps of this current must be limited with a choke.

This choke is installed in the circuit in series with the returning line from the power bus to mains. To do this, it must be connected to the bottom power terminals of the XPS.

The internal switching mechanism of the XPS generates a regenerative current to Mains which is filtered by this choke.

Fagor supplies the chokes that the XPS power supplies necessarily come with.

The following table shows the characteristics of these chokes.

The last section of this chapter describes the mechanical dimensions.

Inductance (10kHz)

Rated current

Peak current

Max. section cable

Operating ambient temperature

Storage temperature-

Relative humidity

Operating vibration

Shipping vibration

Sealing

Weight

CHOKE XPS-25

0.35 mH

50 Amp

100 Amp

10 mm 2

CHOKE XPS-65

0.35 mH

120 Amp

150 Amp

50 mm

5°C - 45°C (41°F - 113°F)

2

-25°C - 60°C (-13°F - 140°F)

80% max.

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP20

8 Kg (17.6 lbs) 23 Kg (50.6 lbs)

The use of these Chokes IS A MUST for the proper operation of the XPS regenerative power supplies.

The length of the cable joining the choke with the power supply must never exceed 2 meters.

Electronic Modules Ver. 0002 EM - 47

EM.7

RESISTOR MODULES: RM-15, ER.

These modules are designed for dissipating the energy excess at the Power Bus when requiring a Ballast resistor with greater power than can be dissipated inside the Power Supply module. They do not need an external power supply.

Stackable module RM-15.

The module can be mounted on either side and it has a safety thermal switch. Next, the general characteristics of the module are described, its derating graph and the power connector data.

The last section of this chapter shows the module dimensions.

The PS-65A and XPS-65 must be connected to two RM-15 modules in parallel. The PS-25A, PS-25B and XPS-25 must be connected to a single

RM-15 module.

The Compact Drives must never be connected to an only RM-15.

Resistance

RMS Power

Peak Energy

RM-15

18 Ohms

1480 Watios

72 kWs (1.2 sec)

Operating ambient temperature 5°C - 45°C (41°F - 113°F) (*)

Thermal switch Klixon NC, 140°C (284°F)

Storage temperature

Relative Humidity

Running vibration

Shipping vibration

-20°C - 60°C (-4°F - 140°F)

95% non condensing at 45°C (113°F)

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

Sealing

Weight

IP2x

4.6 Kg (10.12 lbs)

(*) It may reach 55°C (131°F) but with a 15W/°C reduction

in dissipated power.

1400

1050

Ballast

Power (W)

RM-15

25 (77) 45 (113)

Temp.

°C (°F)

Gap between terminals (mm)

Max. tightening torque (Nm)

Maximum Section (mm2)

RM-15 Power

8.1

1

4

EM - 48 Electronic Modules Ver. 0002

Independent resistors ER.

They are electrical resistors which may also be applied to the Compact Drives.

Here below may be found the general characteristics of these three models.

The last section of this chapter indicates their dimensions:

Resistance

RMS Power

Peak Energy

ER-43/350

43 Ohms

300 Watts

50 kWs (1 sec)

ER-24/750

24 Ohms

650 Watts

100 kWs (1 sec)

ER-18/1100

18 Ohms

950 Watts

150 kWs (1 sec)

Operating ambient temperature

Storage temperature

Relative Humidity

Running vibration

Shipping vibration

Sealing

Weight

5°C - 45°C (41°F - 113°F)

-20°C - 60°C (-4°F - 140°F)

95% non condensing at 45°C (113°F)

460 gr (1.01 lbs)

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP55

920 gr (2.02 lbs) 1250 gr (2.75 lbs)

The rms power data is given for the following conditions: The resistor is mounted vertically, with the connection cables at the bottom and separated at least 10 cm from the closest surface.

The resistor surface may sometimes reach 375 °C (707 °F).

Ohmage.

The following table indicates how to combine resistors RM-15 and ER to obtain the Ohm value required for each Power Supply and compact module.

PS-25x, XPS-25

PS-65A, XPS-65

SCD/ACD 1.15

SCD/ACD 1.25

SCD/ACD 2.50

SCD/ACD 2.75

18 Ohms

9 Ohms

41 Ohms

24 Ohms

12 Ohms

9 Ohms

1.5 kW

950 W

3 kW

1.9 kW

300 W

650 W

1.3 kW

3 kW

1.9 kW

RM-15

ER-18/1100

RM-15 // RM-15

ER-18/1100 // ER-18/1100

ER-43/350

ER-24/750

ER-24/750 // ER-24/750

RM-15 // RM-15

ER-18/1100 // ER-18/1100

Electronic Modules Ver. 0002 EM - 49

EM.8

CAPACITOR MODULE, CM-60

This module stores the energy returned while the motors are braking. Also, in systems sporadically demanding great peak currents from the power bus, it is recommended to install the capacitor module improving the capacity of the bus itself.

This module is connected in parallel to the power bus. Energy wise, it is more efficient than the Resistor module.

Two plates are provided with each module for connecting it to the

Power Bus.

The last section of this chapter shows the module dimensions.

Capacity

Maximum Bus voltage

CM-60

4 mF

797 Vdc

Operating ambient temperature

Storage temperature-

Relative humidity

Operating vibration

Shipping vibration

Sealing

Weight

5°C - 45°C (41°F - 113°F)

-20°C a 60°C (-4°F - 140°F)

95% non condensating at 45°C (113°F)

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP2x

8.6 Kg (18.92 lbf)

EM.9

AUXILIARY POWER SUPPLY MODULE, APS 24

The purpose of this module is to generate the 24 Vdc needed by the power supply and drive modules to power the control circuits. This voltage is supplied through three identical connectors connected in parallel.

The APS 24 includes protections against overcurrent and overvoltage both at the input and at the output.

Using this Power Supply makes no sense in the case of Compact drives or XPS Power Supplies, since they already offer these features.

The last section of this chapter shows the module dimensions.

Metric

Conversion table to mm

Kg·m 2

Nm

°C

Kw

÷ 25.4

÷ 0.113

÷ 0.113

x 1.8

+ 32

÷ 0.746

Imperial inch lb·in·sec 2 lb·in

°F

HP

Output voltage, maximum current

Input voltage

-Singlephase-

Mains consumption

Maximum inrush current

Bus consumption

Maximum Bus voltage

Operating temperature

Storage temperature

Relative humidity

Operating vibration

Shipping vibration

Sealing

Weight

APS 24

24 Vdc (5%), 10 Amp.

380Vac (-15%) - 460Vac (+10%)

50/60Hz

0.75 Amp (380 Vac)

0.63 Amp (460 Vac)

23.9 Amp (460 Vac)

0.5 Amp (540 Vdc)

0.44 Amp (650 Vdc)

790 Vdc

5°C - 45°C (41°F - 113°F)

-20°C - 60°C (-4°F - 140°F)

95% non condensing at 45°C (113°F)

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP2x

4.3 Kg (9.46 lbf)

EM - 50 Electronic Modules Ver. 0002

Very important: In case of microsurges or total mains power outage, this module guarantees the stability of the 24 Vdc for as long as the emergency stop of the motors lasts. This is an absolute must in order to comply with the "CE" requirement for the machine.

This auxiliary power supply has three LEDs to indicate the operating status.

- Red led1: Output overvoltage. The power supply has exceeded 28 Vdc and it is not working.

- Red led2: Output overcurrent. The power supply has exceeded 10 Amps and its output voltage is less than 24 Vdc.

- Green Led: Running OK.

When the power supply quits working due to overvoltage, the module has push-button for system reset.

The last section of this chapter shows the module dimensions.

This APS 24 power supply is to be used to supply to the electrical control circuits and signals to run the drive.

It MUST NEVER be used for the brake of a motor.

The brake may generate voltage peaks that could damage the module.

EM.9.1

APS 24 CONNECTORS

Electronic Modules Ver. 0002 EM - 51

EM.10 PROGRAMMING MODULE, DDS PROG MODULE

The Programming Module is a small portable unit that could replace a PC for setting the parameters and monitoring the system.

It is connected to the Drive module via the serial communications line. It can transfer parameter tables, edit them when setting them, execute commands, monitor internal variables and save that parameter table in its internal nonvolatile memory.

It can also be connected to a PC for transferring parameter tables.

Its electrical installation is limited to the connection of that serial communications line since it receives the 5Vdc supply through it.

It may be built into any of the compact modules ACD or SCD. It can be mounted inside the electrical cabinet onto (32mm) or (35mm) type metallic rails.

It can be shown on the outside of the enclosure using a front adapter supplied by Fagor and described in the last section of this chapter.

The last section of this chapter shows the module dimensions.

Electrical connections:

EM - 52

Operating ambient temperature

Storage temperature

Relative humidity

Operating vibration

Shipping vibration

Sealing

Weight

5°C - 45°C

(41°F - 113°F)

-25°C - 60°C

(-13°F - 140°F)

80% max

10..60 Hz, 0.1..5 G, 2 hr

60..300 Hz, 5 G, 2 hr

IP4x (IP5x front panel)

150 gr (0.330 lbs)

Electronic Modules Ver. 0002

EM.11 FAGOR CABLES

Power cables:

Fagor supplies the cables for transferring electrical power to the motors via three phases with a ground wire. Other cables include two thinner wires used to govern the brake on synchronous motors or for the connection of the thermal switch on the asynchronous motors.

The Fagor cables with their references and mechanical characteristics are:

Reference

MPC - 4 x 1.5

MPC - 4 x 2.5

MPC - 4 x 4

MPC - 4 x 6

MPC - 4 x 10

MPC - 4 x 16

MPC - 4 x 1.5 + (2 x 1)

MPC - 4 x 2.5+ (2 x 1)

MPC - 4 x 4 + (2 x 1)

MPC - 4 x 6 + (2 x 1)

MPC - 4 x 10 + (2 x 1)

MPC - 4 x 35 + (2 x 1)

Motor Power Cable Section

4 x 1,5 mm 2

4 x 2,5 mm 2

4 x 4 mm 2

4 x 6 mm 2

4 x 10 mm 2

4 x 16 mm 2

4 x 1,5 mm 2 + ( 2 x 1 mm 2 )

4 x 2,5 mm 2 + ( 2 x 1 mm 2 )

4 x 4 mm 2 + ( 2 x 1 mm 2 )

4 x 6 mm 2 + ( 2 x 1 mm 2 )

4 x 10 mm 2 + ( 2 x 1 mm 2 )

4 x 16 mm 2 + ( 2 x 1.5 mm 2 )

4 x 25 mm 2 + ( 2 x 1 mm 2 )

4 x 35 mm 2 + ( 2 x 1 mm 2 )

Type:

Flexibility:

Covering:

Temperature:

Work voltage:

Feedback cables:

Several cables are available to the user for connecting encoders, resolvers or encoder simulator boards. Their maximum length is

25 meters (82 ft.). Check this table:

For Sercos connection:

Fagor Automation supplies the fiber optic cables for Sercos communications between the

Group of Drives and the CNC in lengths ranging from 1 to 7 meters.

The cables between drives come with the connectors for each module.

Shielded (EMC compatible)

Great. Especially suited for cable carrying chains with a minimum bending radius of 10 times its diameter.

PUR. Polyurethane immune to the chemical agents used in

Machine Tools.

Working: From -5°C to +70°C (From 23°F to 158°F)

Storage: From -40°C to +90°C (From -40°F to 194°F)

U

0

/U 300 / 500 Volts

Length

1m (3.2ft)

3m (9.8ft)

5m (16.4ft)

10m (32.8ft)

15m (49.2ft)

20m (65.6ft)

25m (82ft)

FEEDBACK CABLES

Reference

Encoder Resolver

EEC-5

EEC-10

EEC-15

EEC-20

EEC-25

REC-5

REC-10

REC-15

REC-20

REC-25

Encoder

Simulation

SEC-1

SEC-3

SEC-5

SEC-10

SEC-15

SEC-20

SERCOS FIBER OPTIC

Length

1m (3.2ft)

Reference

SFO-1

2m (6.4ft)

3m (9.8ft)

5m (16.4ft)

7m (22.4ft)

SFO-2

SFO-3

SFO-5

SFO-7

Electronic Modules Ver. 0002 EM - 53

EM.12 DIMENSIONS

When making the electrical cabinet, also take into account the necessary room for the connectors and their cables. The one for the top power connectors may be up to 45 mm high mm (inches).

EM - 54 Electronic Modules Ver. 0002

Electronic Modules Ver. 0002 EM - 55

EM - 56 Electronic Modules Ver. 0002

EM.13 MODULE IDENTIFICATION.

Each electronic module is identified by its "characteristics plate". It indicates the model and its main technical characteristics.

Versions plate.

Characteristics plate.

The "versions plate" shows the hardware and software versions of the equipment. For example, the IGBT board mounted in this module has version 01A (IGB); the software version is 03.02.

These two plates fully identify the module and must be referred to when repairing or replacing these units. They also help solve compatibility problems between versions.

The drive is also labeled on its package.

Electronic Modules Ver. 0002 EM - 57

User notes:

EM - 58 Electronic Modules Ver. 0002

IN.

INSTALLATION

Follow these steps for a complete system installation:

Prepare the supports for the module in the electrical cabinet.

Unpack and mount all the system modules in the electrical cabinet.

Mount the Mains filter in the cabinet.

Electrical interconnection of the Drive system:

- Power Bus bars at the bottom of each module.

- Ground bars at the top and connection of the assembly to the Ground connection.

- Internal bus between the modules powered by the same Power Supply and the power supply itself.

- Connection to the External Ballast resistor RM-15 or ER if applicable.

Supply voltage. Connection with motors and the CNC:

- Cable hose from mains to the Drive system through the Filter.

- Power cable hose from each Motor to each Drive.

- Feedback cables from each Motor to each Drive.

- Circuit for the control of the Brake.

- Power for the 24Vdc auxiliary power supply from mains (APS 24, XPS or PS-25B).

- Power the control circuits of each drive module with 24 Vdc.

Control and communication signals:

- Encoder simulation cables from each Drive to the CNC if applicable.

- Analog velocity command voltages from the CNC to each Drive.

- Connection of the control signals of the modules, inputs and outputs.

- Sercos connection.

- Identify each system drive with a rotary switch.

- Connect the Modules and the CNC through the fiber optic.

Adjust the modules through the serial line.

In order for the Fagor Servo System to meet the European Directive on

Electromagnetic Compatibility 89/336/CE, the modules installation rules must be strictly followed regarding:

- The mounting of the Filter to Mains

- Electrical installation of the power stage

. Wiring to mains

. Power connection motor-drive

Installation Ver. 0002 IN - 1

IN.1

SECURING ALL THE ELEMENTS

1.- Prepare the fixtures in the electrical cabinet. See the EM chapter -dimensions-.

2.- Unpack the system motors and modules

3.- Mount each of the motors on the machine

4.- Install all the modules making up the Servo-Drive System in the electrical cabinet

IN.1.1

PLACEMENT OF THE SERVO DRIVE SYSTEM

Ambient conditions:

Never install the Servo-Drive System in places where there are corrosive gases.

Always install it well away from areas with unfavorable atmospheric conditions, avoiding exposure to oil, water, hot air, high humidity, excessive dust or metal particles.

Especially:

When installing the RM-15 outside the electrical cabinet, it must be done away from water, coolant, chips, etc. since the module only guarantees a sealing protection of IP2x.

The sealing degree of the ER resistors is: IP55.

It is entirely up to the installer to take care of these matters.

Mechanical conditions:

The Drive system must be mounted vertically in the electrical cabinet. To secure it, use the holes and slots made for that purpose.

Vibrations should be avoided. If necessary use securing means made of a material which absorbs or minimizes vibrations.

To facilitate heat removal, the equipment should be installed so as to leave at least 80 mm

(3.15 inches) above and below it. See figure.

Important:

Mount the Drive Module of greater power next to the Power Supply module and use the same criteria for the rest of the Drive

Modules.

>80 mm (3.15")

IN - 2

Air

>80 mm (3.15")

Installation Ver. 0002

Climate conditions:

Watch that temperature in the electrical cabinet is always kept under 55°C (131°F). Never install the Servo-Drive System beside a heat source.

The modules themselves generate heat. The following table shows the power dissipated by each one of them. These are data to be borne in mind when deciding whether the electrical cabinet needs external cooling or not.

External Ballast resistors RM-15 and ER should be mounted outside the electrical cabinet because they are power dissipating elements which generate a lot of heat. They must be installed away from splashes of water, coolant, metal chips, etc.

When applying external cooling to the system, make sure that water condensation does not fall on the equipment.

Module

PS-25A

PS-65A

PS-25B

XPS-25

XPS-65

AXD 1.08

AXD 1.15

AXD 1.25

AXD 1.35

AXD 2.50

AXD 2.75

AXD 3.100

AXD 3.150

SPD 1.08

SPD 1.15

SPD 1.25

SPD 1.35

SPD 2.50

SPD 2.75

SPD 3.100

SPD 3.150

Dissipated power

160 W

275 W

180 W

180 W

350 W

65 W

110 W

180 W

208 W

335 W

430 W

680 W

1200 W

70 W

135 W

200 W

296 W

385 W

570 W

830 W

1260 W

(*) It depends on how often the protection

Ballast circuit is activated.

Module

APS 24

CM-60

RM-15

ER

ACD 1.08

ACD 1.15

ACD 1.25

ACD 2.50

ACD 2.75

SCD 1.08

SCD 1.15

SCD 1.25

SCD 2.50

SCD 2.75

EMK 3040

EMK 3120

Dissipated power

60 W

0 W

(*)

(*)

92 W

172 W

220 W

415 W

575 W

98 W

173 W

238 W

485 W

677 W

30 W

45 W

Installation Ver. 0002 IN - 3

IN.2

INTER-MODULAR CONNECTION

IN.2.1

POWER BUS CONNECTION

Use 2 of the 3 plates and the washers and nuts supplied with each module to make the connection of the Power bus (lower part of the module). All the modules must be tightly joined to each other guaranteeing a good electrical contact. The tightening torque must be between 2.3 and 2.8 Nm. These plates are identical and no particular order or direction has to be observed.

The Power Supply module must provide the power needed by all the drives connected to it. If the power required by the group of motors exceeds the maximum that a single power supply can provide, two power supplies must be used assigning to each one the supply of a separate group of drives.

System (A) System (B)

The Power Buses of different Power Supply Modules must NEVER be connected in parallel.

Always make separate groups, connecting each Power Supply to a different group of drives.

IN - 4 Installation Ver. 0002

IN.2.2

GROUND CONNECTION

Use the 3rd plate and the washers and nuts supplied with each module for making the ground connection. The tightening torque must be between 2.3 and 2.8 Nm.

Important: Run a grounding cable as short as possible and with a section of 6 mm 2 or larger from one end to the main ground point of the machine.

IN.2.3

INTERNAL BUS CONNECTION

Connect connectors X1 using the cables supplied with each module as shown below.

If the machine uses two separate servo drive systems (each one with its own power supply), they must have two separate internal buses.

Installation Ver. 0002 IN - 5

IN.2.4

CONNECTION TO THE EXTERNAL BALLAST RESISTOR

If the energy to be dissipated when braking the motors is too high, an external ballast resistor must be installed. The Fagor modules "RM-15" and "ER" are designed for this purpose. See the section on Resistor Modules: RM-15, ER" of the chapter EM.

To know whether this module is necessary or not on your machine, refer to the relevant section of the DS chapter.

Electrical configurations and Ohm value.

Configuration for internal resistor

Configuration for external resistor

Ri Re L+ Ri Re L+

C

ONTROL

C

ONTROL

PS-25x, XPS-25

PS-65A, XPS-65

SCD/ACD 1.15

SCD/ACD 1.25

SCD/ACD 2.50

SCD/ACD 2.75

18 Ohms

9 Ohms

41 Ohms

24 Ohms

12 Ohms

9 Ohms

1.5 kW

950 W

3 kW

1.9 kW

300 W

650 W

1.3 kW

3 kW

1.9 kW

RM-15

ER-18/1100

RM-15 // RM-15

ER-18/1100 // ER-18/1100

ER-43/350

ER-24/750

ER-24/750 // ER-24/750

RM-15 // RM-15

ER-18/1100 // ER-18/1100

The Ohm value of the external Ballast resistor must be the same as that of the internal resistor of that module.

NEVER connect an external resistor in parallel with the internal Ballast resistor. It may cause severe damage to the system.

Compact Drives MUST NEVER be connected to the RM-15 module.

IN - 6 Installation Ver. 0002

Heat dissipation.

Ballast resistors can generate a great deal of heat. Optionally, a PAPST 614 type fan may also be installed for better dissipation.

The figure and table below show the temperatures reached in the gap above the module and the fan effect.

5

10 cm

3.93"

3

6

2

4

30 cm

11.8"

65 cm

25.6"

1

Above the RM-15 and ER the air temperature may reach 120°C (248°F).

Therefore, it should be mounted away from the rest of the modules or even outside the electrical cabinet, always vertically and away from cables and other temperature sensitive material.

Warning: The RM-15 module guarantees a sealing degree of IP2x.

The ER guarantees a degree of IP55.

Installation Ver. 0002 IN - 7

IN.3

POWER LINE CONNECTION

IN.3.1

CABLING OF THE SYSTEM TO MAINS

Possible safety elements and adaptation to mains.

Some mandatory protection elements must be inserted on the lines going from Mains to the servo drive system. Other elements may be optional.

The diagram shows which these possibilities are and how to connect them.

After the main switch Q1, there is a transformer or autotransformer. It adapts the mains to the 380-460 Vac range.

Some chokes in line may help smooth the mains interferences.

Then, the filter for electromagnetic interference.

And the fuses MUST BE installed before the power switch.

IN.3.1.1

MAINS FILTER, EMK.

In order for the Fagor Servo drive system to meet the European Directive on

Electromagnetic Compatibility 89/336/CE the EMK Mains filter, must also be installed.

To install it, it must be properly connected to ground and the wires connecting to the power supply module must be as short as possible. See the figure for ground connection.

In the following table is shown the appropriate filter for each module.

If we choose not to install the mains filter

"EMK", a choke should be inserted on each line instead, a transformer or an autotransformer that minimizes mains disturbances.

These solution do not assure compliance with the afore mentioned CE directive.

Module

PS-25x, XPS-25

PS-65A, XPS-65

ACD/SCD 1.xx

ACD/SCD 2.xx

Filter

EMK 3040

EMK 3120

EMK 3040

EMK 3120

IN - 8 Installation Ver. 0002

IN.3.1.2

FUSES.

To protect the Servo Drive system, fuses must be included on the lines coming from Mains.

The fuses are selected according to the characteristics indicated in the first table. The second table offers a group of fuses from different manufacturers which be used.

Installation Ver. 0002 IN - 9

IN.3.1.3

TRANSFORMER OR AUTOTRANSFORMER.

If the Mains voltage has to be adapted to the system levels, an isolating transformer or autotransformer must be used. This element will help reduce the mains harmonics, although it does not assure compliance with the CE directive.

When having a mains perfectly referenced to ground, autotransformers may be used to adapt to the mains voltages.

However, when having a mains not referenced to ground, an isolating transformer must be used because dangerous overvoltage could appear on some phases with respect to ground which could damage the equipment. In this case, the secondary must have a star connection with its middle point connected to ground to the mains neuter line.

On systems with XPS power supplies, the transformer must have a very low impedance which could be negligeable as compared to the inductive value of the CHOKE XPS-xx.

IN.3.1.4

LINE INDUCTANCE

Line Inductance means including chokes on each of the three power lines. Its function is to reduce the harmonics generated in mains. The recommended value is given by the formula below. To simplify the choice, we could consider optimum the values given in the table.

L

=

2

V

π

⋅ f

I r m s

L (mHr)

I rms (A)

PS-25A

PS-25B

1

40

PS-65A

0.4

100

ACD/SCD

1.08/15

5

11

ACD/SCD

1.25

3

18

ACD/SCD

2.50

1.5

36

ACD/SCD

2.75

1

53

If the "Power Pro" filter has not been installed, the Line Inductance is recommended in order to minimize disturbances, although is warned that this does not guarantee CE marking compliance.

No Line Inductances must be installed in line with XPS power supplies since they would interfere with their regenerating function.

IN - 10 Installation Ver. 0002

IN.3.1.5

SECTION OF THE CABLES FOR MAINS CONNECTION.

The table on the right gathers the regulation applicable to typical installations of Drive Systems.

Determines the maximum current in continuous duty cycle, admitted by three-phase conductors in PVC hoses and installed on the machines through conduits and channels.

The ambient temperature considered is 40 °C (94 °F).

At any rate, the section of the mains connection cables must be equal to or greater than that of the cables used to connect any motor.

Section

(mm 2 )

1.5

2.5

16

25

35

4

6

10

Max Current

(Amp RMS)

12.2

16.5

53

67

83

23

29

40

To determine the cables needed to connect the Power Supply to Mains, proceed as indicated in the DS chapter.

This is the cable selection offered by Fagor: Reference number of cables x section (mm 2 )

MPC - 4 x 1.5

MPC - 4 x 2.5

MPC - 4 x 4

MPC - 4 x 6

MPC - 4 x 10

MPC - 4 x 16

MPC - 4 x 1.5 + (2 x 1)

MPC - 4 x 2.5 + (2 x 1)

MPC - 4 x 4 + (2 x 1)

MPC - 4 x 6 + (2 x 1)

MPC - 4 x 10 + (2 x 1)

MPC - 4 x 16 + (2 x 1.5)

MPC - 4 x 25 + (2 x 1)

MPC - 4 x 35 + (2 x 1)

Installation Ver. 0002 IN - 11

IN.3.1.6

MECHANICAL CHARACTERISTICS OF THE CONNECTORS

Module

AXD 1.08/15, SPD 1.08/15

AXD 1.25, SPD 1.25,

SCD 1.08/15/25, ACD 1.08/15/25

PS-25A, AXD 1.35, SPD 1.35

EMK 3040, AXD 2.50/75, SPD 2.50/75

PS-65A (ballast), XPS-65 (ballast)

ACD 2.50/75 (ballast), SCD 2.50/75 (ballast)

PS-25B

XPS-25

ACD 2.50/75 (power), SCD 2.50/75 (power)

EMK 3120, AXD 3.100, SPD 3.100

AXD 3.150, SPD 3.150

PS-65A (power), XPS-65 (power)

Gap between terminals (mm)

7.5

Max. tightening torque (Nm))

0.6

Maximum

Section (mm 2 )

2.5

7.5

8.1

0.6

1

4

4

10.1

10.1

12.1

15.1

18.8

1.7

7

7

1.5

2

10

25

50

10

16

IN - 12 Installation Ver. 0002

IN.3.2

MOTOR/DRIVE CONNECTION

When connecting the Drive module with its corresponding motor, connect terminal "U" of the drive module with the terminal corresponding to the

"U" phase of the motor.

Same as terminals "V-V", "W-W" and "Ground-Ground".

In order for the system to comply with the European Directive on

Electromagnetic Compatibility, the hose grouping all four cables U-V-W-

Ground must be shielded and must be connected only at the drive end as shown on the diagrams. These conditions are a must.

U

V

W

DRIVE

+24 Vdc

FXM MOTOR

F

E

A U

B V

C W

D

-

+

3

M

Holding Brake

(Option)

Ready Made Cables

MPC-4x...(mm 2 )+2x1

MPC-4x...(mm 2 )

MC 23, MC 46 or MC 80 socket

A

B

E D

F

C

MC 23 or

MC 46 socket.

DRIVE

N.C. Thermal

Switch (150°C)

U

V

W

Ready Made Cable

MPC-4x...(mm 2 )+2x1

Ready Made Cable

MPC-4x...(mm 2 )

Installation Ver. 0002

SPM MOTOR

U1

V1

W1

3

M

Star

Connection

IN - 13

IN.3.2.1

GUIDE FOR SELECTING THE POWER CABLES OF THE MOTORS

The following tables serve as guides for selecting the power cables of the synchronous motors (FXM) and of the asynchronous motors (SPM).

They show the right cable section for each motor.

They meet the European directive and the mechanical compatibility with the drive and motor connectors.

(A) In these cases, do not use the angled socket -AMC- .

(O) In order to meet regulations on current density, these cables must not be run in channels.

FXM11.20A.xx.xx0

FXM11.30A.xx.xx0

FXM11.40A.xx.xx0

FXM12.20A.xx.xx0

FXM12.30A.xx.xx0

FXM12.40A.xx.xx0

FXM13.20A.xx.xx0

FXM13.30A.xx.xx0

FXM13.40A.xx.xx0

FXM14.20A.xx.xx0

FXM14.30A.xx.xx0

FXM14.40A.xx.xx0

FXM31.20A.xx.xx0

FXM31.30A.xx.xx0

FXM31.40A.xx.xx0

FXM32.20A.xx.xx0

FXM32.30A.xx.xx0

FXM32.40A.xx.xx0

FXM33.20A.xx.xx0

FXM33.30A.xx.xx0

FXM33.40A.xx.xx0

FXM34.20A.xx.xx0

FXM34.30A.xx.xx0

FXM34.40A.xx.xx0

FXM53.12A.xx.xx0

FXM53.20A.xx.xx0

FXM53.30A.xx.xx0

FXM53.40A.xx.xx0

FXM54.12A.xx.xx0

FXM54.20A.xx.xx0

2,4

4,0

6,0

8,0

3,2

5,5

3,1

2,3

3,5

4,6

3,1

0,8

1,1

1,5

1,5

2,3

4,7

6,2

0,8

1,0

0,8

1,1

1,5

0,3

0,4

0,5

0,5

1,0

1,6

2,0

Best Option

FXM54.30A.xx.xx0

FXM54.40A.xx.xx0

FXM55.12A.xx.xx0

FXM55.20A.xx.xx0

FXM55.30A.xx.xx0

FXM55.40A.xx.xx0

FXM73.12A.xx.xx0

FXM73.20A.xx.xx0

FXM73.30A.xx.xx0

FXM73.40A.xx.xx0

FXM74.12A.xx.xx0

FXM74.20A.xx.xx0

FXM74.30A.xx.xx0

FXM74.40A.xx.xx0

FXM75.12A.xx.xx0

FXM75.20A.xx.xx0

FXM75.30A.xx.xx0

FXM75.40A.xx.xx0 (*)

FXM76.12A.xx.xx0

FXM76.20A.xx.xx0

FXM76.30A.xx.xx0

FXM76.40A.xx.xx0 (*)

FXM77.12A.xx.xx0

FXM77.20A.xx.xx0

FXM77.30A.xx.xx0 (*)

FXM77.40A.xx.xx0 (*)

FXM78.12A.xx.xx0

FXM78.20A.xx.xx0

FXM78.30A.xx.xx0 (*)

FXM78.40A.xx.xx0 (*)

(*) MC 46

17,3

26,5

35,7

12,5

20,6

31,0

41,2

12,9

19,3

25,3

9,3

15,4

22,6

31,0

10,9

11,3

15,4

6,2

10,4

15,4

20,6

7,7

8,1

10,2

4,0

6,8

10,2

13,3

4,7

7,8

A

A

A

A

A

Valid Options

O

IN - 14 Installation Ver. 0002

Installation Ver. 0002

FXM53.12A.xx.xx1

FXM53.20A.xx.xx1

FXM53.30A.xx.xx1

FXM53.40A.xx.xx1

FXM54.12A.xx.xx1

FXM54.20A.xx.xx1

FXM54.30A.xx.xx1

FXM54.40A.xx.xx1

FXM55.12A.xx.xx1

FXM55.20A.xx.xx1

FXM55.30A.xx.xx1

FXM55.40A.xx.xx1

FXM73.12A.xx.xx1

FXM73.20A.xx.xx1

FXM73.30A.xx.xx1

FXM73.40A.xx.xx1 (*)

FXM74.12A.xx.xx1

FXM74.20A.xx.xx1

FXM74.30A.xx.xx1 (*)

FXM74.40A.xx.xx1 (*)

FXM75.12A.xx.xx1

FXM75.20A.xx.xx1

FXM75.30A.xx.xx1 (*)

FXM75.40A.xx.xx1 (*)

FXM76.12A.xx.xx1

FXM76.20A.xx.xx1 (*)

FXM76.30A.xx.xx1 (*)

FXM76.40A.xx.xx1 (**)

FXM77.12A.xx.xx1

FXM77.20A.xx.xx1 (*)

FXM77.30A.xx.xx1 (*)

FXM77.40A.xx.xx1 (**)

FXM78.12A.xx.xx1

FXM78.20A.xx.xx1 (*)

FXM78.30A.xx.xx1 (**)

FXM78.40A.xx.xx1 (**)

(*) MC 46 (**) MC 80

15,3

20,0

7,1

11,7

17,0

23,1

9,3

15,6

23,1

3,6

6,0

9,0

12,0

4,8

8,3

12,2

15,3

6,0

10,2

39,8

53,6

18,8

30,9

46,5

61,8

30,9

11,6

19,4

29,0

38,0

14,0

23,1

33,9

46,5

16,4

26,0

A

A

A

A

Best Option Valid Options

(A) In these cases, do not use angled sockets

-AMC- .

IN - 15

SPM 90L xx.1

SPM 90P xx.1

SPM 100LBE xx.1

SPM 112ME xx.1

SPM 112LE xx.1

SPM 112XE xx.1

SPM 132L xx.1

SPM 132X xx.1

SPM 132XL xx.1

SPM 160M xx.1

SPM 160L xx.0

SPM 180MA xx.0

7,8

10,1

13,8

18,6

24,0

33,9

47,7

56,2

62,3

65,5

76,0

87,0

Best Option Valid Options

IN - 16 Installation Ver. 0002

IN.3.3

GROUND CONNECTION

The ground connections of the drives (screwed-on plates) must go to a single point and from there to the ground terminal of the electrical cabinet. When applying a 10A current between this ground point and any of these points, the voltage drop must not exceed 1 Volt.

When not having a separate ground point, join the plates to the terminal of the Power Supply module which, in turn, will be connected to Mains Ground.

CE directive.

In order to ensure compliance with the European Directive on

Electromagnetic Compatibility 89/336/CE, It is a must to:

- power the system through mains filter EMK

- secure the Filter onto a metallic support with a good contact on its whole base, good ground connection and as close to the Power Supply as possible.

- Make all the Ground connections indicated on the next figure with a cable having a section equal to or greater than the three-phase power supply and at least 6 mm 2 .

- always use shielded cables for three-phase motor connections.

Installation Ver. 0002 IN - 17

IN.4

CONNECTING THE MOTOR FEEDBACK TO THE DRIVER

Use the cable with connectors supplied by Fagor to lead the motor feedback to connector X4 of the Drive module. The motor feedback can be one of two types: encoder or resolver.

IN.4.1

EEC ENCODER CONNECTION

(HD,

Sub-D,

M26)

Front View

19

26

1

9

Signal Pin

COS

REFCOS

SIN

REFSIN

+485

-485

GND

+8V

1

10

2

11

19

20

25

23

TEMP

TEMP

CHASSIS

21

22

26 to DRIVE -X4-

Ready Made Cable EEC 5/10/15/20/25

(Length in meters; including connectors)

Cable 4x2x0,14 + 2x0,5

Green

Yellow

Blue

Pink

Grey

Brown

Black

Red

White

Purple

Twisted pair. Overall shield.

Metallic shield connected to CHASSIS pin

- at the Drive end and at the Motor end -

Pin

5

6

2

8

1

7

10

12

3

4

9

E0C 12

Front View

7

8

12

9

10

1

2

6

5

11

4

3 to MOTOR

IN.4.2

REC RESOLVER CONNECTION

Front View

19

(HD,

Sub-D,

M26)

1

Signal

S1

S3

S4

S2

R1

R2

Pin

8

17

9

18

7

16

Ready Made Cable REC 5/10/15/20/25

(Length in meters; including connectors)

Cable 4x2x0,25

Red

Black

Blue

Black

Green

Black

26

9

TEMP

TEMP

CHASSIS

21

22

26 to DRIVE -X4-

White

Black

Shielded by pairs of cables, and overall shield.

All shields interconnected and connected to the same CHASSIS pin.

- only at the Drive end -

7

8

Pin

3

4

5

6

1

2

R0C 9

Front View

8

7

6

5

9

1

2

3

4 to MOTOR

IN - 18 Installation Ver. 0002

IN.5

BRAKE CONTROL

To govern the mechanical brake optionally incorporated on some motors, they have to be supplied with:

- 24 Vdc, for FXM -axis motors-

- 220 Vac for SPM -spindle motors-.

The consumption power of the brakes is indicated on chapters SM and AM.

A simple transformer-rectifier circuit like the one below should be enough to power the FXM motor brake.

220 Vac

220/24

+

-

24 Vdc

Ready Made Cables

MPC-4x...(mm 2 )+2x1

A

B

E

D

F

C

MC 23 or

MC 46 socket.

F

E

MC 23, MC-46 or MC 80 socket

-

+

Holding Brake

(Option)

24V Released

0V Holding

FXM MOTOR

220 Vac

220 Vac

50 Hz

SPM MOTOR

Holding Brake

(Option)

220Vac Released

0V Holding

Applying the indicated voltages releases the motor shaft.

When installing the motor, verify that the brake fully releases the shaft before turning it for the first time.

The 24 Vdc generated by modules like the PS-25B, APS 24 or XPS, or that being generated by another power supply handles the control signals of the drive MUST NEVER be used to also control these brakes.

These brakes generate voltage peaks that can damage the drive.

On the FXM, watch that no voltage over 26 V is applied which would prevent the shaft from turning.

Installation Ver. 0002 IN - 19

IN.6

CONTROL POWER SUPPLY FOR THE MODULES

The internal circuits of all electronic modules need 24 Vdc.

The PS-25A and PS-65A power supply modules and modular Drives must be supplied with this voltage through their X2 connector.

These modules have stabilizing system for the supplied voltage.

The maximum consumption of each module is: PS Power Supply .... 1 Amp.

Modular Drive ............2 Amps.

Important:

The 24 Vdc voltage supply is essential for the system to run.

The APS 24 auxiliary power supply offers these 24 Vdc and 10 Amp.

Regenerative power supplies XPS-25 and XPS-65 and the PS-25B power supply are selfsupplied and they also offer 8 Amps of these 24Vdc.

Compact Drives are self-supplied and offer up to 110 mA of these 24 Vdc.

Important:

All these 24 Vdc power supplies assure the presence of this voltage as long as the motor braking lasts due to mains power outage.

This is a must for obtaining the "CE seal" for the machine.

These 24 Vdc can also be used in the circuit of the electrical cabinet, but

NEVER to activate the brake of a motor.

Connection of the APS power supply.

Mains

L1

L2

APS 24

X1

1

3

(Phoenix,

7.62 mm)

X2

1

X3 X4

3

(Phoenix,

5.08 mm)

PS

X2

1

0 Vdc

+24 Vdc

9

10

(Phoenix,

5.08mm)

X2

1

DRIVES......

X2

1

7

8

(Phoenix,

5.08mm)

7

8

(Phoenix,

5.08mm)

IN - 20 Installation Ver. 0002

Connection of the PS-25B and XPS power supplies

Mains

L1

L2

XPS

PS-25B

X3

1

3

(Phoenix,

7.62 mm)

X4

1

X5 X6

3

(Phoenix,

5.08 mm)

X2

1

DRIVES......

X2

1

0 Vdc

+24 Vdc

7

8

(Phoenix,

5.08mm)

7

8

(Phoenix,

5.08mm)

Installation Ver. 0002 IN - 21

IN.7

CONTROL AND COMMUNICATION SIGNALS

Connect the encoder simulator signal to the CNC.

If the Drive is going to work with analog interface, take the ±10 Vdc velocity command from the

CNC.

When working with Sercos interface, identify the Drives and connect them with each other.

IN.7.1

ENCODER SIMULATION CONNECTION, SEC

Depending on the type of motor feedback, the drive generates a set of signals that simulate the TTL signals of an encoder mounted onto the rotor of the motor.

Take these signals from the Drive to the CNC with the SEC cable.

9

(Sub-D,

M15)

Front View

15

1

8

Signal

A

/A

B

/B

Io

/Io

AL

/AL

GND

CHASSIS to CNC

Pin

1

2

5

6

3

4

7

8

11

Ready Made Cable SEC 1/3/5/10/15/20

(Length in meters; including connectors)

Cable 4x2x0,14 + 2x0,5

Green

Yellow

Blue

Pink

Grey

Brown

White

Purple

Black

Twisted pair. Overall shield.

Metallic shield connected to CHASSIS pin

- at the CNC end and at the Drive end -

Pin

1

2

3

4

5

6

7

8

11

15

11

(HD,

Sub-D,

F15)

Front View

5

1 to DRIVE -X3-

IN.7.2

DIRECT FEEDBACK CONNECTION

When using the drive as a positioning drive (with the 8070 CNC or independently -Motion

Control-).

Take these signals from the feedback to the drive.

Front View

2

1

4

9

5

8

6

7

Signal

+5Vdc

GND

A

/A

B

/B

Io

/Io

Pin

5

6

7

8

9

1

2

4 to Feedback

Sensor

Fagor Sensor Cable EC-PD 1/3/6/9/12

(Length in meters; including connectors)

Cable 4x2x0,14

Brown

White

Green

Yellow

Blue

Red

Grey

Pink

Twisted pair. Overall shield.

Metallic shield connected to Chassis pin

- at the Sensor end and at the Drive end -

Pin

1

2

3

9

11

4

5

6

11

15

(HD,

Sub-D,

M15)

Front View

1

5

15 to DRIVE -X3-

IN - 22 Installation Ver. 0002

IN.7.3

ANALOG VELOCITY COMMAND

Take the analog velocity command from the CNC to the Drive.

Connector X7 of the drive has two analog inputs. By means of an internal parameter

IP1 -F00900-, it is possible to select which one the drive has to attend to.

F00900 = 1 Main input (Analog Input 1, pins 4/5 of X7)

F00900 = 2 Auxiliary input (Analog Input 2, pins 2/3 of X7)

The connector offers ±15 Vdc to easily generate the velocity command with a potentiometer.

X8 connector

CNC8055 Fagor

Analog Input 2

Analog Input 1

-15vdc

+15vdc

(-)

(+)

(-)

(+)

3

4

5

6

7

1

2

8

9

10

11

DRIVE

11

(Phoenix,

3.5mm)

Front view

1

IN.7.4

DIGITAL OUTPUTS

When the drive digital outputs are connected to inductive loads, we must protect the optocoupler with circuits such as the ones shown here:

DC

1N4000

Vbr=2.4Vdc

IF=Load

(1 Ohm)

R ~1 Ohm

C

0.1-1mF 250V

AC/DC

AC/DC

R ~1 Ohm

C

0.1-1mF 250V

Installation Ver. 0002 IN - 23

IN.7.4

SERCOS CONNECTION

Identification.

Distinguish each Drive by means of the 16-position rotary switch (Node_Select) with sequential numbers starting from One. After any change at the Node_Select switch, the module has to be reset for the change is assumed.

Important:

Give to the SERCOSIS parameters of the CNC the same id numbers as the ones assigned by means of the Node_Select switch. See drawing.

If the same motor is to be used as "C" axis and "spindle", the two CNC tables must have the same value for the SERCOSID parameter.

If the Zero identifier is assigned to a Drive, that module will be ignored, even when the ring stays closed for all purpose for the rest of the elements. That drive may receive the velocity command in an analog way and can be adjusted through the serial line.

Important:

For example, a system with four drives identified as 1,2,3,4. If we wish to ignore the second one, we must renumber some of the other ones so they are sequential. The easiest way would be: 1,0,3,2.

Remember that the SERCOSID parameters of the CNC can also be modified the same way.

Interconnection.

Connect in the Sercos ring all the drives that will be governed by the CNC.

Connect, with each fiber optic line, an OUT terminal with another IN terminal. See drawing.

Each Drive comes with a fiber optic line to connect it to the adjacent module. Fagor provides the other necessary fiber optic lines upon request.

If the machine has two separate servo drive systems (each with its own power supply) and a single CNC, the same ring must interconnect all the drives of the machine.

IN - 24 Installation Ver. 0002

IN.7.5

SERIAL LINE CONNECTION

To transfer the parameter table and set up the system, the drive must be connected to a PC-

compatible computer or with the Programming Module "DDS PROG MODULE" through a serial line.

The metal shield must be soldered to the hood of the connector at the Drive end. The pins labeled as "Reserved" in the drawings MUST NOT be connected anywhere by the operator.

Serial line to a PC.

If the PC has more than one serial port, it must be selected by means of the setup window of the communication program WinDDSSetup. See the GSU chapter

The "serial port" of the PC may be accessible through either a 9-pin or a 25-pin SUB-D type connector.

9

6

(Sub-D,

F9)

Front View

5

1

Signal

FG

RxD

TxD

DTR

DSR

CTS

GND

CHASSIS

Pin

1

2

3

4

6

8

5 to DRIVE -X5-

9

6

(Sub-D,

F9)

Front View

5

1

Signal

FG

RxD

TxD

DTR

DSR

CTS

GND

CHASSIS

Pin

1

2

3

4

6

8

5

Overall shield.

Metallic shield connected to CHASSIS pin

- only at the Drive end -

Pin Signal

1

2

3

4

6

8

5

FG

RxD

TxD

DTR

DSR

CTS

GND

9

6

(Sub-D,

F9)

Front View

5

1 to PC

Pin

1

2

3

20

6

5

7

Signal

FG

RxD

TxD

DTR

DSR

CTS

GND

25

14

(Sub-D,

F25)

Front View

13

1

Installation Ver. 0002 IN - 25

Serial line to DDS PROG MODULE.

The line labeled as +5V is only required when using the Programming Module "DDS PROG

MODULE".

When mounting the Programming Module away from the drive, the screw located next to the connector should be connected to a Chassis pin.

9

6

(Sub-D,

F9)

Front View

5

1

Signal

FG

RxD

TxD

+ 5Vdc

GND

CHASSIS

Pin

3

4

6

8

5

1

2 to DRIVE -X5-

Overall shield.

Metallic shield connected to CHASSIS pin

- only at the Drive end -

Pin Signal

3

4

6

8

5

1

2

FG

RxD

TxD

+ 5Vdc

GND

9

6

(Sub-D,

F9)

Front View

5

1 to DDS PROG MODULE

IN - 26 Installation Ver. 0002

IN.8

CONNECTIONS

Connection of an SPD module with an SPM spindle motor and encoder feedback.

OUT

IN

GND

DRIVE ENABLE

SPEED ENABLE

DR O.K.

0 V

+24 Vdc

IN-1

IN-2

IN-3

IN-4

OUT-1

OUT-2

OUT-3

OUT-4

Analog Input 2

Analog Input 1

(-)

(+)

-15vdc

+15vdc

Analog Output 2

Analog Output 1

(-)

(+)

(-)

(+)

(-)

(+)

DC Power Bus

Internal Bus

Wire-Ribbon

Cable

Modular Digital Spindle Drive

SPD 2.50-SI-1

Ready Made Cable to NC

SEC 1/3/5/10/15/20

(Length in meters; including connectors)

1

4

NODE

SELECT

OUT

IN

X1

11

15

X3

1

5

(HD,

Sub-D,

M15)

Encoder

Simulator

(Option)

Io

/Io

Reserv.

Reserv.

A

/A

B

/B

0 V

X3

7

8

5

6

3

4

1

2

11

Green

Yellow

Blue

Pink

Grey

Brown

White

Purple

Black

(Sub-D, M15)

7

8

5

6

3

4

1

2

11

15

9

8

1

X1

1

9

2

10

(HD, Sub-D, F15)

10

3

4

5

6

7

8

X2

1

2

2.5 Amp

(F) Fuse

X2

1

8

(Phoenix,

5.08mm)

26

19

X4

(HD,

Sub-D,

F26)

9

1

COS

REFCOS

SIN

REFSIN

+485

-485

GND

+8V

TEMP

TEMP

21

22

26

1

10

2

11

19

20

25

23

X4

Ready Made Cable

EEC 5/10/15/20/25

(Length in meters; including connectors)

Green

Yellow

Blue

Pink

Grey

Brown

Black

Red

White

Purple

E0C 12

3

4

9

8

X2

6

2

7

1

5

10

12

Front View

2

3

9

1

1012

11

4 5

8

7

6

PTC

A1 Board

X6

7

8

9

10

11

12

13

1

2

3

4

5

6

L+

IP10

IP11

IP12

IP13

OP10

OP11

OP12

OP13

X6

1

13

P2

P1

1

(HD, Sub-D, M26)

U

V

W

220 Vac

50 Hz

N.C. Thermal

Switch (150°C)

X7

8

9

10

11

1

2

3

4

5

6

7

OV2

OV1

-15v

+15v

P2

IV2

P1

IV1

OP2

OP4

OP1

OP3

X7

11

Ready Made Cables

MPC-4x...+2x1

6

9

X5

1

5

Serial Line

Interface

Board

X5

RxD

TxD

+5V

GND

2

3

4

5

MPC-4x...

220 Vac

50 Hz

Wire necessary only when using the Programming

Module.

L-

(Sub-D, F9)

X3

X1

U1

V1

W1

Electric Fan

3

M

4

5

2

3

RxD

TxD

+5V

GND

(Sub-D, F9)

6

9

Star

Connection

Spindle Motor

SPM...E...

PC-Computer or

Programming Module

1

5

Installation Ver. 0002 IN - 27

Connecting an AXD module with an FXM servomotor and resolver feedback.

Ready Made Cable

REC 5/10/15/20/25

(Length in meters; including connectors)

X4

26

9

S1

S3

S4

S2

R1

R2

8

17

9

18

7

16

19 1

(HD,

Sub-D,

F26)

TEMP

TEMP

21

22

26

Red

Black

Blue

Black

Green

Black

White

Black

R0C 9

7

8

5

6

3

4

1

2

X2 X2

Front View

2

1

3

4

9

8

7

5

6

PTC

U

V

W

X4

(HD, Sub-D, M26)

MPC-4x...(mm 2 )+2x1

Ready Made Cables MPC-4x...(mm 2 )

MC-23 or MC-46 socket

+24 Vdc

E

D

C

F

B

A

X1

MC-23 or

MC-46 base.

Holding Brake

(Option)

F

X1

E

A U

B V

C W

3

M

D

Electric

Fan

1

2

3

1

Axis Motor

FXM...R0...

3

2

IN - 28 Installation Ver. 0002

Connection of an SCD module with a spindle motor SPM and encoder feedback.

+24 Vdc

0 V.

110 mA máx

ERROR RESET

DRIVE ENABLE

SPEED ENABLE

DR. O.K.

PROG. OUT

Analog Input 2

(-)

(+)

Analog Input 1

(-)

(+)

-15vdc

+15vdc

Analog Output 2

Analog Output 1

(-)

(+)

(-)

(+)

MPC-4x...

OUT

IN

L1

L2

IN-1

IN-2

IN-3

IN-4

OUT-1

OUT-2

OUT-3

OUT-4

Must be greater than

Internal Ballast Resistor.

External Ballast

Digital Spindle Compact Drive

SCD 2.50 ...

Ready Made Cable to CNC

SEC 1/3/5/10/15/20

(Length in meters; including connectors)

4

NODE

SELECT

OUT

IN

11

15

X3

1

5

(HD,

Sub-D,

M15)

Encoder

Simulator

(Option)

Io

/Io

Reserv.

Reserv.

A

/A

B

/B

0 V

U

V

W

X3

7

8

5

6

11

3

4

1

2

Green

Yellow

Blue

Pink

Grey

Brown

White

Purple

Black

X1

1

2

3

X2

1

2

3

4

5

6

7

8

9

10

X1

1

1 Amp

(T) Fuses

A1 Board

X6

7

8

9

10

11

12

13

1

2

3

4

5

6

3

(Phoenix,

7.62 mm)

(HD, Sub-D, F15)

X4

Internal use.

OP5

X2

1

X4

26

19

(HD,

Sub-D,

F26)

9

1

COS

REFCOS

SIN

REFSIN

+485

-485

GND

+8V

TEMP

TEMP

10

1

10

2

11

19

20

25

23

21

22

26

(HD, Sub-D, M26)

Ready Made Cable

EEC 5/10/15/20/25

(Length in meters; including connectors)

Green

Yellow

Blue

Pink

Grey

Brown

Black

Red

White

Purple

220 Vac

50 Hz

IP10

IP11

IP12

IP13

OP10

OP11

OP12

OP13

X6

1

13

N.C. Thermal

Switch (150°C)

P2

P1

X7

8

9

10

11

1

2

3

4

5

6

7

OV2

OV1

-15v

+15v

P2

IV2

P1

IV1

OP2

OP4

OP1

OP3

X7

1

11

Ready Made Cables

MPC-4x...+2x1

MPC-4x...

220 Vac

50 Hz

Wire necessary only when using the Programming

Module.

L1

L2

L3

Ri

Re

L+

6

X5

1

Serial Line

Interface

Board

X5

RxD

TxD

+5V

GND

4

5

2

3

9

5 (Sub-D, F9)

(Sub-D, M15)

X3

X1

E0C 12

3

4

9

8

1

5

6

2

7

10

12

X2

7

8

5

6

11

3

4

1

2

15

9

U1

V1

W1 3

M

4

5

2

3

RxD

TxD

+5V

GND

(Sub-D, F9)

6

9

Front View

2

3

1

9

1012

11

4 5

8

7

6

PTC

8

1

Electric Fan

Star

Connection

Spindle Motor

SPM...E...

PC-Computer or

Programming Module

1

5

Installation Ver. 0002 IN - 29

IN.9

ELECTRICAL CABINET DRAWINGS

Let us first see which is the system power-up procedure.

The internal control circuits of each Power supply module, Drive or compact drive must be supplied with 24Vdc.

Compact modules, XPS power supplies and the PS-25B power supply do not need an external 24 Vdc power supply. These modules need two-phase 380-460 Vac.

Each module verifies its hardware and internal configuration.

If the status is correct, the DRO.OK contacts are closed.

If all the drives are OK, the Power Supply closes its "System OK" contact.

We supply mains power to the Power Supply module.

The Power Supply "loads" the Power Bus with a "Soft Start".

We activate the Drive_Enable control input of each Drive.

We activate the Speed_Enable control input of each Drive and the System_Speed_Enable input of the Power Supply.

The motor is now ready to follow the velocity command given by the CNC.

The following diagrams for power and control circuits in the electrical cabinet are only orientative for the technician designing the machine and they may be further completed or simplified at will according to each application.

Next, we offer a brief description of the function of each part of the circuit.

When turning the main switch on (Q1), the 24 V power supply powers the control circuit of each module. These circuits perform an internal test of the module. If there is no errors, the corresponding Driver_OK contact closes and this status is communicated to the Power

Supply module via the internal bus. If all the modules associated with a Power supply are "OK" and the latter does not detect any errors in its own module, it closes the System_OK contact.

In the case of the compact modules as well as the XPS and PS-25B power supplies, the closing of Q1 must take two phases to connector X1 without the need for external fuses.

Emergency line. The D1 relay confirms that the system is mechanically and electrically in working condition and it will be activated by the System_OK contact of the Power Supply. D1 will be deactivated if an emergency occurs at the CNC, if the operator presses the E-stop button (mushroom), if the SPM motor overheats or if any axis of the machine hits the end-oftravel (limit) switch. A normally open push-button is included in parallel with the limit switches in order to be able to take apart the axes of the machine.

We are now ready to turn on the system by pushing the ON button which activates contactor

K1. By pushing OFF, power can be removed.

Error Reset. Should any module have errors, its Driver_OK and the System_OK would be open, D1 deactivated, and the Power Supply could not be powered up. Some of these errors may be eliminated by applying 24 Vdc to the Error_Reset pin of the Power Supply. The errors are reset by means of the contact associated with the ON button. This may cause the

Driver_OK and System_OK contacts to close activating D1 and, while ON is pressed, activate K1.

IN - 30 Installation Ver. 0002

This circuit configuration joins the error reset and the system power-up in a single pushbutton.

Activating D2 activates the relay D3 which in turn confirms the Drive_Enables of all drive modules. The green and red lamps indicate that there is or not motor torque (Drive_Enable).

When activating the System_Speed_Enable signal of the power supply, the D2 contact is executed.

Now, the CNC may enable each axis (CNC_Enable) and confirm the Speed_Enable signal to each drive by means of D4, D5, D6 and D7. Remember that a drive will only respond to an external velocity command when the Drive_Enable, Speed_Enable and

System_Speed_Enable signals are active (24 Vdc).

Stop. When D1 is deactivated on the emergency line or the OFF button is pressed, K1 is deactivated and the power supply loses its three-phase power. The System_Speed_Enable signal drops and, with zero velocity command, the motors try to stop.

To obtain a controlled stop, with torque:

- the drives' control circuits must be under power and

- the Drive_Enable signal must remain active while braking the motor.

These two points are obtained:

- using a 24Vdc power supply that maintains those 24Vdc by using the energy returned by the motor to the power bus. The auxiliary power supply APS 24, as well as the internal power supplies of the XPS, PS-25B, and compact modules meet this condition. (24 Vdc

(*) on the diagrams)

- delaying the cancelling of D3 and using a maintained 24Vdc voltage to activate the

Drive_Enable pin shown with an asterisk (*) on the diagram.

When opening Q1, the braking must also be controlled.

Controlling the brake. In some applications, the Z axis on a milling machine, a electromechanical brake is used over the rotor in order to lock it.

The brake holds the rotor when it loses voltage at its terminals. Therefore, when the machine is down, the brake locks the Z axis so it does not drop. The reaction time of a brake may be anywhere from 200 ms to several seconds.

While the brake is locking the motor, the motor must be kept with torque. To do this, the drive has parameter GP9 -S00207- DriveOffDelayTime. This GP9 indicates how long the drive will maintain its torque active after stopping the motor (speed ~ 0) . GP9 -S00207- is given in milliseconds. By assigning to GP9 a value slightly larger than the brake holding time, one assures that the axis does not drop in emergency stops.

When powering the machine up, the brake must not be released until the system assumes control of that axis. This can also be controlled by means of internal variable

TV100 -F01702- TorqueStatus.

Installation Ver. 0002 IN - 31

RM-15, (or ER)

RESISTOR

MODULE

N.C. Thermal

Switch (RM-15)

Ri

Re

L+

PS-xxA.

POWER

SUPPLY

L1

L2

L3

3x380-460 Vac

L1

L2

L3

X1

Drive Module of greater power next to the

Power Supply.

SPD

SPINDLE

DRIVE

Internal

Bus

Power

Bus

L1

L2

2x380-460 Vac

X1

1

2

3

U

V

W

U

V

W

U

V

W

U

V

W

S

AXD

X

AXIS

DRIVE

AXD

Y

AXIS

DRIVE

X1

X

X1

Y

X1

AXD

Z

AXIS

DRIVE

Z

X1

L1

L2

APS 24. AUXILIARY

POWER SUPPLY

1

X1

3

(Phoenix,

7.62 mm)

CM-60.

CAPACITOR

MODULE

+24 Vdc

1

X2

10

(Phoenix,

5.08mm)

9

10

5

6

7

8

1

3

X2

X2

1

8

(Phoenix,

5.08mm)

2.5 Amp

(F) Fuse

1

2

3

4

5

6

7

8

X2

X2

1

8

(Phoenix,

5.08mm) 2.5 Amp

(F) Fuse

6

7

8

4

5

1

2

3

X2

X2

1

8

(Phoenix,

5.08mm) 2.5 Amp

(F) Fuse

3

4

5

6

7

8

1

2

X2

X2

1

8

(Phoenix,

5.08mm) 2.5 Amp

(F) Fuse

6

7

8

3

4

5

1

2

X2

X2 X3 X4

1

3

(Phoenix,

5.08 mm)

1

2

3

X2

ON

Gnd

Error Reset

System Speed Enable

SYSTEM

OK

D2

+24 Vdc

Chassis

+24 Vdc

Gnd

Drive Enable

Speed Enable

DR.S

OK

D7

Gnd

Drive Enable

Speed Enable

DR.X

OK

Gnd

Drive Enable

Speed Enable

DR.Y

OK

+24 Vdc (*)

D4

D5

Gnd

Drive Enable

Speed Enable

DR.Z

OK

D3

D6

+24 Vdc

+24 Vdc

+24 Vdc

Gnd Chassis

Modular system with PS-xxA.

IN - 32 Installation Ver. 0002

Modular system with PS-xxA

Installation Ver. 0002 IN - 33

IN - 34

L1

L2

L3

3x380-460 Vac

L1

L2

2x380-460 Vac

CHOKE XPS-xx

(Only with XPS)

10 mm 2 (XPS-25)

50 mm 2 (XPS-65)

Ri

Re

L+

XPS-xx or

PS-25B

POWER

SUPPLY

L1

L2

L3

1

2

3

X3

L1

L2

X1

Internal

Bus

CH1 CH2

(Only in XPS)

Power

Bus

1

X2

7

(Phoenix,

5.08mm)

X4 X5 X6

1

3

(Phoenix,

5.08 mm)

1

2

3

1

3

5

6

7

8

X2

X4

U

V

W

SPD

SPINDLE

DRIVE

S

Drive Module of greater power next to the

Power Supply.

X1

AXD

X

AXIS

DRIVE

U

V

W

X

X1

U

V

W

U

V

W

AXD

Y

AXIS

DRIVE

Y

X1

AXD

Z

AXIS

DRIVE

Z

X1

ON

Gnd

Error Reset

System Speed Enable

SYSTEM

OK

D2

+24 Vdc

+24 Vdc (*)

+24 Vdc

X2

1

8

(Phoenix,

5.08mm)

2.5 Amp

(F) Fuse

1

2

3

4

5

6

7

8

X2

Chassis

Gnd

Drive Enable

Speed Enable

DR.S

OK

D3

D7

+24 Vdc

+24 Vdc

X2

1

8

(Phoenix,

5.08mm)

2.5 Amp

(F) Fuse

1

2

3

4

5

6

7

8

X2

Gnd

Drive Enable

Speed Enable

DR.X

OK

D4

+24 Vdc

X2

1

8

(Phoenix,

5.08mm) 2.5 Amp

(F) Fuse

4

5

6

7

8

1

2

3

X2

Gnd

Drive Enable

Speed Enable

DR.Y

OK

D5

+24 Vdc

X2

1

8

(Phoenix,

5.08mm) 2.5 Amp

(F) Fuse

6

7

8

3

4

5

1

2

X2

Gnd

Drive Enable

Speed Enable

DR.Z

OK

D6

Gnd

Modular system with

XPS or PS-25B.

Installation Ver. 0002

In this schematics, the cancelation of K1 is being delayed so the motor braking is done by returning energy to mains.

Modular system with

XPS or PS-25B.

Installation Ver. 0002 IN - 35

Ri

Re

L+

COMPACT

DRIVE

MODULE

L1

L2

L3

3x380-460 Vac

L1

L2

L3

L1

L2

2x380-460 Vac

X1

1

2

3

L1

L2

2

OUT IN

Ri

Re

L+

X

1

X2

COMPACT

DRIVE

MODULE

10

(Phoenix,

5.08mm)

1

2

3

4

5

9

10

6

7

8

X2

+24 Vdc (*)

Gnd

ON

D3

Error Reset

Drive Enable

Speed Enable

DR.X

OK

Chassis

+24 Vdc

D4

+24 Vdc

L1

L2

L3

3x380-460 Vac

L1

L2

L3

L1

L2

2x380-460 Vac

X1

1

2

3

L1

L2

1

OUT IN

Z 1

X2

10

(Phoenix,

5.08mm)

6

7

8

9

10

3

4

5

1

2

X2

+24 Vdc (*)

Gnd

D3

Error Reset

Drive Enable

Speed Enable

DR.Z

OK

Chassis

D6

+24 Vdc

IN OUT

FAGOR

CNC

Compact modules do not have the System_Speed_Enable signals.

In this schematics, in spite of having Sercos interface, electrical signals are used to activate the enables.

IN - 36

Compact system with Sercos

Installation Ver. 0002

Compact system with Sercos

Installation Ver. 0002 IN - 37

CHOKE XPS-xx

10 mm 2 (XPS-25)

50 mm 2 (XPS-65)

Ri

Re

L+

L1

L2

L3

3x380-460 Vac

L1

L2

2x380-460 Vac

X3

1

2

3

L1

L2

L3

L1

L2

XPS-xx

REGENERATIVE

POWER

SUPPLY

CH1 CH2

X1

Internal

Bus

AXD

X

AXIS

DRIVE

U

V

W

X

X1

3

OUT IN

Power

Bus

OUT2

U

V

W

AXD

Z

AXIS

DRIVE

X6

8

9

OUT2

Z

2

OUT IN

X1

L1

L2

L3

3x380-460 Vac

X1

L1

L2

L3

L1

L2

2x380-460 Vac

1

2

3

L1

L2

1

OUT IN

COMPACT

DRIVE

MODULE

S

+24 Vdc +24 Vdc

2.5 Amp

(F) Fuse

3

4

5

6

7

8

1

2

X2

2.5 Amp

(F) Fuse

3

4

5

6

7

8

1

2

X2

7

8

5

6

1

3

X2

1

2

3

X4

ON

Gnd

Error Reset

D2

System Speed Enable

SYSTEM

OK

+24 Vdc (*)

Chassis

Gnd

Drive Enable

Speed Enable

DR.X

OK

D3

Gnd

Drive Enable

Speed Enable

DR.Z

OK

Gnd +24 Vdc

3

4

5

6

9

10

7

8

1

2

X2

Gnd

ON

D3

Error Reset

Drive Enable

Speed Enable

DR.S

OK

Chassis

IN OUT

FAGOR

CNC

Mixed system with Sercos

IN - 38 Installation Ver. 0002

Brake connection

Mixed system with Sercos

Installation Ver. 0002 IN - 39

User notes:

IN - 40 Installation Ver. 0002

GSU. COMMON SETUP

This chapter describes some of the steps of the adjustment process for the drive module

DDS. It only considers the ones that are common to the "Velocity drive" and "Position drive" applications. The specific steps of each application are described in the following SSU and

PSU chapters.

GSU.1 MODULE POWER-UP

When powering up the DDS module or doing a Reset, various messages appear on the seven-segment display:

1.- Initializing stages: values 1, 2, 3 and 4 are shown.

2.- Software version, after the "r" with the identifying digits.

3.- Error listing.

4.- Warning list.

5.- Return to step 3.

Phases shown on the 7-segment display (04.01 version) DDS

PHASE 1 PHASE 2

PHASE 3 PHASE 4

Common Setup Ver. 0002 GSU - 1

GSU.2 DATA STORAGE STRUCTURE

Both the PC and the Programming module as well as the Drive itself have nonvolatile memory: the hard disk and the Flash memories respectively. These systems keep the stored data even when power is removed.

Also, the Drive has another two memory areas used for its internal operation and communications: Internal memory and RAM memory. The diagram below shows the interconnection between all of them.

PC or

PROGRAMMING MODULE

DDS Drive

Flash Memory

Non

Volatile

PC

RAM Memory

Disk

Flash Memory PROG. MOD.

Internal Memory

Very important:

The operation of the Drive depends on the data stored in its internal memory.

GSU - 2 Common Setup Ver. 0002

GSU.3 WINDDSSETUP

With the Fagor program WinDDSSetup (Windows based) it is possible to set up the Drive through the serial line.

To install this program at the PC, execute setup.exe which comes in Floppy Disk number 1 of the DDS-SETUP.

Important:

The minimum PC hardware requirements for the proper operation of the

WinDDSsetup are:

486 microprocessor at 66 MHz and 16 Mb of RAM.

It may also be adjusted from the portable Programming Module "DDS PROG MODULE" although with fewer choices than those offered by the PC program.

Common Setup Ver. 0002 GSU - 3

GSU.4 ACCESS LEVELS

A parameter table determines the operation of the Drive depending on the motor it governs and on the desired behavior.

All these parameters, variables and commands of the Drive are organized by access levels.

These levels are: 1.- USER level.

2.- OEM level.

3.- FAGOR level

To access each parameter, the drive must be set up at the access level required by that parameter. See appendix A.

The access to each level requires a password.

To change the access level from the WinDDSSetup program, execute the "Access Level" option on the "SetUp" menu. The bottom of the screen shows the currently active level.

The USER level is the basic level. On power up, the Drive access this level by default, thus not requiring password.

At USER level, it is possible to access a group of parameters that slightly modify the behavior of the Drive depending on the application developed.

(Free access).

The OEM level is an intermediate access level. Appendix A describes which variables, parameters and commands may be accessed from this level.

At OEM level, it is possible to access a large group of parameters depending on the motor being connected which set how the electronics of the Drive is adapted to that particular motor and to the particular application being developed. (Access restricted to the Fagor Servo Drive System installer).

The FAGOR level allows full access to all system variables, parameters and commands.

At Fagor level, it is possible to access a group of parameters depending on the electronics of the drive and that are factory sets. (Access restricted to the manufacturing process and technicians from Fagor Automation).

GSU - 4 Common Setup Ver. 0002

GSU.5 PARAMETER EDITING

Regarding the editing of parameters, the following warning must borne in mind:

Important:

The editing of parameters with WinDDSSetup or with the portable Programming

Module affects all the data stored in the drive's RAM memory.

Edit

PC RAM Memory

Internal Memory

Only the modification of certain parameters (CP30 -F00308-, SP1 -S00100-,

SP2 -S00101-, SP4 -S00211-, SP5 -S00212-, SP30 -F01603-, SP31 -F01604-,

OP1 -F01400-, OP2 -F01401-, OP3 -F01402- and OP4 -F01403-) also affects the data stored in internal memory.

These parameters may be changed On-Line.

In order for the changes made in RAM memory to have an effect on the Drive's behavior, they must be Saved into Flash memory and the Drive module must be Reset.

See the following sections of this chapter.

Common Setup Ver. 0002 GSU - 5

GSU.6 SAVE INTO FLASH MEMORY

In order for the values given to the parameters during setup stay as a permanent Drive configuration, they must be transferred into the Flash memory.

1st.The Drive must be connected to power.

2nd.Save the parameters

To do this, execute the command to save into Flash.

• At the WinDDSSetup, press the button

• With the command ParametersToFlash of the portable programming module.

When it is done saving, the Status Display will display the OK message or the errors (if any). Then, it requests whether the Drive is to be Reset or not.

RAM to Flash

PC

Flash Memory

Non

Volatile

RAM Memory

3rd.Then, the Drive should be Reset.

GSU - 6 Common Setup Ver. 0002

GSU.7 INITIALIZATION PROCESS

Turning the Drive causes it to Reset. This reset may also be caused by the user:

• By means of the push-button located on top of the drive module.

• With the SoftReset command of the portable programmable module.

• At the WinDDSSetup program using the [GV11] Soft Reset command. See figure.

This Reset has the following effect:

• The Status Display shows the initialization sequence.

• The data stored in the Flash memory (parameters and variables defining its configuration) go into RAM memory, and from it into the internal memory.

• The data is cross-checked and verified.

• Any detected errors are indicated on the display of the face plate.

Error Reset.

If the system detects any errors, their cause must be removed and then, an "Error Reset" must be done.

Electrically, through pin X2(1) of the Power Supply (pin X2(3) at the Compact).

• Executing the command: [DC1] Reset Errors at the WinDDSSetup program.

There are errors considered as "non-resettable", See Appendix B.

These errors can only be eliminated by a Reset of the Drive.

Reset

PC

Flash Memory

Non

Volatile

RAM Memory

Internal Memory

Common Setup Ver. 0002 GSU - 7

GSU.8 TRANSFERRING PARAMETER TABLES

From the Flash of the Drive to the hard disk of the PC:

• at the WinDDSSetup program, press it is used to save the configuration of a drive

From the hard disk of the PC to the Flash of the drive:

• at the WinDDSSetup program, press it is used to copy a known configuration into a new Drive.

Disk

PC

Flash Memory

Non

Volatile

RAM Memory

From RAM of the Drive to the hard disk of the PC:

• at the WinDDSSetup program, press

Warning: This operation saves into the PC the parameter table stored in RAM of the drive, which cannot coincide with the data stored in the Flash of the drive.

• at the portable module, execute the command: "Parameters\Save DDS->PM"

Disk

PC RAM Memory

GSU - 8 Common Setup Ver. 0002

GSU.9 MOTOR IDENTIFICATION

Each motor appearing in this manual requires a specific configuration of the drive software.

This software contains a table with the right parameter data for each of these motors.

Appendix A shows which parameters are related to the motor.

In order to set the right values in these motor-related parameters, one must communicate to the drive which motor it is going to govern.

At the WinDDSSetup program, select the editing of M parameters.

At the OEM access, click on the button to select the motor.

Common Setup Ver. 0002 GSU - 9

The motor selection window will be similar to one of these:

Motor with Encoder feedback.

Motor with Resolver feedback.

When the Motor uses Encoder feedback:

The new Fagor motors equipped with Encoder feedback (ref. E0, E1 or A0) store the motor sales reference in the encoder's permanent memory.

Software version 03.03 and later are capable of reading this reference and executing an automatic motor identification process. This way, the motor selection window only offers the possibility to choose between the motor currently connected and a "user motor".

This automatic process does not include the adjustment of the PI which must be done by the user.

When the motor uses Resolver feedback:

Fagor Motors equipped with Resolver feedback (ref. R0) do not have auto-identification.

One must inform the drive module of which motor is connected to it. The selection window offers the full range of motors. If the connected motor is, for example, the FXM32 of 2000 rpm, select FXM322 in this window.

Important: The selection of the motor using these selection windows modifies the

MP1 -S00141- MotorType. Assigning a particular reference to parameter

MP1 -S00141- means that all the motor parameters (shown in Appendix A with an M) take a fixed value that cannot be changed.

GSU - 10 Common Setup Ver. 0002

Motor identification and initialization.

The motor may be identified through the initialization button .

Selection and initialization window:

The motor selection using this procedure sets the motor parameters and also sets the rest of the parameters of the drive to their default values.

Within the group of parameters expanded in Sets and Reductions, this initialization only affects those belonging to set and reduction Zero. Set 0 and Reduction 0 are left as the only useful ones.

This identification process + initialization is the starting point recommended for the first start-up of a servo system.

Automatic identification process on motors with Encoder feedback.

When connecting the EEC feedback cable for the first time, the Drive reads the reference stored on the encoder, identifies the motor and initializes the parameters.

After this automatic setup, modifying parameter MP1 -S00141- MotorType will have no effect on the drive.

Only when they are given a "user motor" value (a name starting with zero) its motor parameters may be changed.

The voltage supply loss of the drive or disconnecting the EEC feedback cable will have no effect on the parameter values. Only when the drive detects a different motor connected to it, will it start a new automatic setup process.

Common Setup Ver. 0002 GSU - 11

User motor.

When installing a non-Fagor motor (user motor) or to get access to certain "motor parameters", MP1 -S00141- MotorType must be loaded with a value starting with "0", for example, 0supermotor.

The drive software only admits one user motor. To keep the parameter tables of several

"user motors", the various parameter transferring functions must be used. See the previous section on "transferring parameter tables".

Save to Flash.

Remember that after any of the identification processes described earlier, the motor reference is stored in RAM memory of the drive and it still has no effect on how it runs. Therefore:

After the adjustment by any of the previous methods, it is necessary to Save the parameter table into Flash Memory.

On power-up or after a Reset, the system will check that the value given to

MP1 -S00141- MotorType (manually or automatically) is correct. In other words, that the motor and the drive are compatible with each other. The error codes will identify the mistake made.

GSU - 12 Common Setup Ver. 0002

GSU.10 POSITION OR VELOCITY DRIVE

After identifying the motor other adjustments are necessary.

The drive, with the CNC and the feedback, is ready to work with different configurations.

Parameter AP1 -S32- configures the drive to work with each of these configurations.

Velocity drive (see SSU chapter) a) Velocity drive with encoder simulator.

Motor

CNC

CNC

Position

Loop

Drive

S32 = xxx010

Encoder

Simulator

Velocity

Loop

Current

Loop

Motor Feedback

Input

M

S b) Velocity drive with direct feedback.

CNC

CNC

Position

Loop

Drive

S32 = xxx010

Velocity

Loop

Current

Loop

Motor Feedback

Input

Motor

M

S

Direct

Feedback

Common Setup Ver. 0002 GSU - 13

Position drive (see PSU drive) c) Position drive without direct feedback.

CNC Drive

CNC

Position

Loop

S32 = xxx011

Velocity

Loop

Current

Loop

Motor Feedback

Input

Motor

M

S d) Position drive with direct feedback.

CNC Drive

CNC

Position

Loop

S32 = xxx100

Velocity

Loop

Current

Loop

Motor Feedback

Input

Motor

M

S

Direct

Feedback

Resume the setup as indicated in the following chapters SSU and PSU for the "Velocity Drive" and "Position Drive" respectively.

GSU - 14 Common Setup Ver. 0002

GSU.11 ADJUSTMENT OF THE ENCODER OFFSET

After adjusting the control loops, the motor might make a high-pitch noise due to some misadjustment in the generation of feedback signals. To solve this problem, the offsets and the gains used by the drive software to handle the feedback signals must be adjusted.

Circle adjustment.

It is the process that adjusts the processing of the feedback signals so the Sine and

Cosine signals (RV1 -F01506-, RV2 -F01507-) are mathematically correct. In other words, they have to make a perfect circle.

Adjustment procedure:

- Make the motor turn very slowly, at about 5 to 10 rpm.

- Set variable RV8 -F01519- to "1". This will start the automatic adjustment.

- Monitor this variable RV8 -F01519- .

- When RV8 -F01519- recovers its default value (0), the adjustment will be concluded.

This procedure, which may last up to 2 minutes, modifies the values of

RP1 -F01500-, RP2 -F01501-, RP3 -F01502- and RP4 -F01503-, eliminating the noise and improving the control over the motor.

Once this procedure is completed, Save to Flash and do a Reset .

Rotor Sensor

H V 2-X 3 B o ard Id

R P 3 -F 15 02R P 1 -F 15 00-

Feedback

SineOffset

Feedback

SineGain

X4 (DDS)

From Motor

Sensor

G P 2 -F 70 1-

1: Resolver

G P 2 =0

G P 2 =1

G P 2 =2

Sensor

Evaluation

R P 4 -F 15 0 3R P 2 -F 15 01-

Feedback

CosineOffset

Feedback

CosineGain

R V 1 -F 15 0 6-

R V 2 -F 15 0 7-

Sensor

Position

R P 5 -F 15 0 4FeedbackResolver

RhoCorrection

Position

Speed

Encoder

R V 3 -F 15 0 8Feedback

RhoCorrection

S V 2 -S 40 -

VelocityFeedback

To Speed Loop

Common Setup Ver. 0002 GSU - 15

GSU.12 CURRENT FILTER ADJUSTMENT

The current loop parameters are factory set for each drive and each motor. Almost all of them require a Fagor access level to be edited.

Current loop diagram:

+24V

Drive Enable

X2(2)

Current Loop

0V

From

Speed

Loop

C P 2 0

-F 3 0 7 -

Current

Limit

Low-Pass

Filter

C P 3 0 -F 3 0 8 -

C P 3 1 -F 3 1 2 -

Current-PI

CV3 -F311-

3 2

CV1

-F309-

CV2

-F310-

PWM Enable

GP1 -F700-

PWMFrequency

GP3 -F602-

StoppingTimeout

U

V

W

H V1 -S 110- D riveP eakC urrent

CurrentUOffset

CV10 -F305-

CurrentVOffset

CV11 -F306-

3

M

Encoder or

Resolver

Motor

MP1

MP2

..

MP14

SP11

SP12

CP1

CP2

CP3

FP1

FP2

FP20

FP21

FP30

..

FP38

Synchronous Motor

Adapter- Current-PI

C P 1

0 .5 *C P 1

C P 2

K p

T i

C P 1 -S 1 0 6 - C u rre n tP ro p o rtio n a lG a in

C P 2 -S 1 0 7 - C u rre n tIn te g ra lT im e

Speed

Asynchronous Motor

Adapter-Current-PID

C P 4 *C P 1

C P 2

T i

C P 5 *C P 2

C P 1

K p

Speed

C P 6 C P 7

C P 4 -F 3 0 1 - C u rre n tA d a p ta tio n P ro p o rtio n a lG a in

C P 5 -F 3 0 2 - C u rre n tA d a p ta tio n In te g ra lT im e

C P 6 -F 3 0 3 - C u rre n tA d a p ta tio n L o w e rL im it

C P 7 -F 3 0 4 - C u rre n tA d a p ta tio n U p p e rL im it

GSU - 16 Common Setup Ver. 0002

Parameters CP20 -F00307- and CP30 -F00308- can be modified at the OEM access level.

Current command limit CP20 -F00307-

It is a parameter that is factory set to the value that protects the motor and the drive against overcurrent.

- On servo systems with an FXM motor, CP20 takes the smaller of the values given by the peak current of the drive and that of the motor.

- On systems with an SPM motor, it takes the value of the maximum current of the drive. On applications requiring lots of power when threading, the value of CP20 may be up to 15% higher than the maximum current of the drive.

Current command filter, CP30 -F00308- and CP31 -F00312-

Some FXM motors generate a high-pitch noise that may be eliminated using a lowpassing filter for the current command.

This filter is not applicable to systems using SPM motors.

This filter may be configured by giving its natural frequency and the damping factor.

Break frequency:

Giving to CP30 -F00308- CurrentFilter1TimeConstant a value between 0 and 8, sets the break frequency of this filter.

Current Command Filter:

Fc

Low Pass Filter

Frecuency

Common Setup Ver. 0002 GSU - 17

User notes:

GSU - 18 Common Setup Ver. 0002

SSU. VELOCITY DRIVE SETUP

This chapter describes the setup procedure for DDS drive module when used as "Velocity

Drive". The necessary steps for the application as "Position Drive" are described in the next

PSU chapter.

SSU.1 ADJUSTMENT OF THE OFFSET OF THE ANALOG SIGNAL

Power the Drive on. The next step is to eliminate the possible offset of the analog command.

When using Sercos interface, this section is not applicable.

Send 0V command to the drive. Monitor the motor speed at the CNC or by "watching" the

SV2 -S00040-. Assign values to the offset parameter SP30 -F01603-, (with the opposite sign of SV2 -S00040-) until the motor stops completely. But, careful, this way, only the drive's offset is eliminated, the CNC may have another offset. Now adjust the CNC offset.

To adjust the offset of the whole control loop, get the CNC in dro mode but with the

“Drive_Enable” and “Speed_Enable” active, give values to SP30 -F01603- until the motor stops. Another procedure may be to set a position for the axis with the CNC and adjust

SP30 -F01603- until the following error is symmetrical (same in both directions).

After having determined the proper value, the result has to be Saved into Flash memory and the unit must be Reset. Procedure explained in the GSU chapter.

Apart from this adjustment mechanism, there is a potentiometer (See drawing, P1) designed so the user can correct the slight drifts suffered by the electrical components with time.

Same for Analog input 2 with SP31 -F01604- and P2.

X6

X7

1

13

P2

P1

1

11

Analog Input 2

X7(3)

X7(2)

P 2

S P 3 1

-F 0 1 6 0 4 -

IP 1

-F 0 0 9 0 0 -

IP1=2

IP 1 = 1

IV 2 -F 0 0 9 0 6 -

IV 1 -F 0 0 9 0 5 -

S P 3 0

-F 0 1 6 0 3 -

P 1

X7(5)

X7(4)

Analog Input 1

Velocity Drive Setup Ver. 0002 SSU - 1

SSU.2 VOLTS-SPEED OF THE ANALOG VOLTAGE

On equipment having an analog interface and on spindle drives with Sercos interface, one must indicate the relationship between the analog voltage and the velocity command.

There are three parameters to set this voltage-speed relationship.

SP20 -F00031- and SP21 -F00081- establish the voltage/speed ratio of the velocity command.

SP21 -F00081- is allocated the maximum speed to be supplied by the motor in our application. And SP20 -F00031- is allocated the analog voltage to be applied for that maximum speed. The hardware limits SP20 -F00031- to 10000 millivolts (10 Volts).

SP10 -S0091- sets the maximum velocity command effective at the drive. Its value is given by the characteristics of the motor and those of the machine.

The drive's software does not allow SP10 -S0091- values greater than 10% over the rated

(nominal) motor speed. If the instantaneous speed of the motor exceeds the SP10 value over

12%, Overspeed error 200 will be issued.

Example:

If the application requires a speed of 4000 rpm. when applying an analog voltage of 9.5 V, and the motor has a nominal speed of 4000 rpm, the values for these parameters could be:

SP20=9500 millivolts

SP21=4000 rpm

SP10=4200 rpm

SP10, SP20, SP21: mV

10000

SP20

Avoid setting parameters

SP21 -F00081- and SP10 -S0091to similar values in order to allow instantaneous speed values greater than the

SP21 -F00081- values.

The modification of these parameters has no on-line effect.

They stay in the drive's RAM memory. To make them effective, they have to saved into Flash memory and the equipment must be re-initialized.

500

0

0/

SP2

1

RATI

O SP2

SP21

1000 2000 3000 4000

SP10

SP10 x 1.12

rpm

X7(5)

V (+)

V (-)

X7(4)

Volts/Rev Ratio

S P 2 0 - V o lts

S P 2 1 - R e v .

If SV2>(SP10*1.12) then Error 200

Velocity

Feedback

S V 2

S P 1 0

Velocity

Limit

S V 7

Velocity

Command

Final

PI

SSU - 2 Velocity Drive Setup Ver. 0002

SSU.3 PARAMETERS FOR THE ENCODER SIMULATOR

The Drive can generate a simulated incremental Encoder output with differential TTL signal from the signal of the motor feedback.

They are square signals A and B, their inverted signals /A and /B, and reference marks Io and

/Io.

This is an optional feature.

The Encoder simulator is programmable by means of the following parameters:

EP1 -F00500- Number of pulses per turn.

EP2 -F00501- The point where the reference marker pulse is generated I

0

,

EP3 -F00502- Counting direction.

SSU.3.1

NUMBER OF PULSES

The number of pulses must be programmed before starting up the motor using parameter EP1 -F00500-.

SSU.3.2

MARKER PULSE (HOME I

0

) POSITION

It is the location of the reference mark. The inverted marker pulse signal ( /I

0

) is also available.

The home position may be set by following any of these two different procedures:

1stOrient the rotor shaft to the desired home position.

Then, execute the command EC1 -F00503-.

2ndMove the marker pulse point by means of parameter EP2 -F00501-.

For example: if EP1 -F00500- is 1250 and we wish to move the current marker pulse position 58°, we must load parameter EP2 -F00501- with a value of 1250*58/360 which is approximately equal to 200.

The range for this parameter varies from 1 to the value assigned to parameter

EP1 -F00500- although it is recommended to reset it to "1". If a home value greater the number of pulses defined by EP1 -F00500- is indicated, the initialization process will generate error 500.

Example

EP1 -F500-

EP2 -F501-

= 1250

= 20 0

EP3 -F502= 0

Rotor

1125

1000

1250

125

Io

250

875

750

625

500

375

Velocity Drive Setup Ver. 0002 SSU - 3

SSU.3.3

COUNTING DIRECTION

For the turning direction of the diagram below (clockwise), the encoder simulator generates the A signal 90° ahead of the B signal when parameter EP3 -F00502- has its default value

EP3 = 0.

If EP3 = 1, the simulator will generate the B signal 90° ahead of the A signal for the same turning direction of the motor.

Obviously, the opposite turning direction (counterclockwise) inverts the order of the signals.

A

B

Io

EP3 = 0

90° PHASE-SHIFT

CLOCKWISE TURN t

A

B

Io

EP3 = 1

90° PHASE-SHIFT t

SSU.3.4

PIN-OUT OF THE ENCODER SIMULATOR CONNECTOR

Drive connector X3 is the one outputting the signals generated by the encoder simulator.

Encoder Simulator

X3(1)

X3(2)

X3(3)

X3(4)

X3(5)

X3(6)

A

A

B

B

Io

Io

X3(11)

GND

H V2-X3 Board Id

EP1 -F500-

EncoderSimulatorPulsesPerTurn

EP2 -F501-

EncoderSimulatorI0Position

EP3 -F502-

EncoderSimulatorDirection

SSU - 4 Velocity Drive Setup Ver. 0002

SSU.4 ANALOG OUTPUTS

The DDS module has two analog outputs at connector X7 between pins 10 and 11 (channel 1) and pins 8 and 9 (channel 2) which can be programmed for displaying the various internal variable of the drive. Anyway, the most common ones are:

1.- Velocity loop

3.- Rotor sensor

5.- Function generator.

2.- Torque parameters

4.- Encoder simulator

The variables are selected by means of parameters OP1 -F01400- and OP2 -F01401-.

OP3 -F01403- and OP4 -F01404- set the values of these variables corresponding to an analog output voltage of 10 Vdc. The modification of these variables has an immediate effect

(on line). To keep the values of these parameters, they have to be saved into Flash memory.

1

X6

13

P2

P1

1

X7

11

X7(11)

X7(10)

±10 Volts

max.

X7(9)

X7(8)

Physical Analog Outputs

OV1 -F01408-

DA1Value Channel 1

Ref

D/A

OP1 -F01400- DA1IDN

OP3 -F01402-

DA1ValuePer10Volts

OV2 -F01409-

DA2Value

Ref

D/A

Channel 2

OP2 -F01401- DA2IDN

OP4 -F01403-

DA2ValuePer10Volts

Variable examples for OP1 and OP2

SV2 -S00040- VelocityFeedback

SV7 -F01612- VelocityCommandFinal

TV1 -S00080- TorqueCommand

TV2 -S00084- TorqueFeedback

CV3 -F00311- CurrentFeedback

.... and more

Analog outputs as adjustment tools.

With an oscilloscope connected to these analog outputs, it is possible to monitor those internal variables of the Drive and check overshooting, stabilizing times, accelerations, system stability, etc.

For example, to display the torque and instant speed signals:

OP1=SV2 Actual speed via channel 1, pins 10/11 of connector X7

OP2=TV2 Actual torque via channel 2, pins 8/9 of connector X7

OP3=100 (100 rpm / 10 volts)

OP4=1 (1 deciNm / 10 volts)

Velocity Drive Setup Ver. 0002 SSU - 5

The figure shows a possible look of the oscilloscope screen and its interpretation depending on the gains set.

During the setup process, it is common practice to monitor the velocity command

(SV1 -S00036-) and the actual speed (SV2 -S00040-).

CALCULATION OF VALUES

Speed = 100 rpm/10volts * 2 volt/division * 3 divisions = 60 rpm

Torque= 1 dNm/10volts * 5 volt/division * 2 divisions = 1 dNm = 0.1Nm

Torque = 1 dNm

Tek Hold: 2.5kS/s

Speed = 60 rpm

130 Acqs --.-- k

0

Channel 1

2 volts per line

(Speed)

Ch1 2 V Ch2 5 V 100ms Ch 1 -1.08 V

Channel 2

5 volts per line

(Torque)

Total sampling time

(One sample per millisecond)

Warning:

Give to OP3 -F01403- and OP4 -F01404 values that cannot be reached by the chosen internal variables. This way, the output will never exceed the ±10V range.

For example, if the speed is not expected to ever exceed 2500 rpm, the gain may be set in 2500 rpm/10 volts or greater.

If the values given to OP3 -F01403- and OP4 -F01404 are too small, the electrical signal will be saturated when reaching ±10 V.

The WinDDSSetup program for setting the drive up from a PC includes an oscilloscope.

This way, the setup is much easier.

SSU - 6 Velocity Drive Setup Ver. 0002

SSU.5 VELOCITY LOOP SETTING

The next step consists in adjusting the velocity loop. To do this:

- We will use the internal velocity command generator of the drive itself.

- We will adjust the PI of the velocity loop.

- We can filter this command using the acceleration limit and/or the choke.

The next sections describe these steps in detail.

SSU.5.1

VELOCITY COMMAND GENERATOR

This function generates velocity commands internally. When activated, the drive ignores the analog signal coming from the outside. This function can be used for moving the system with known analog voltages and, then, monitor their behavior.

It can generate two types of signals: square and DC. Their frequency and amplitude are programmable. The squarewave is commonly used to see how the system reacts when faced with a step. For example:

WV4=1

WV1=1

WV2=160

WV3=600

Activates the internal generator. Velocity command.

Squarewave.

Period of 160ms (6.26 Hz)

Amplitude of the velocity command corresponding to 600 rpm.

... and after adjusting the PI and the filter described in the next sections...

WV4=0 Deactivates the internal generator.

The motor will turn trying to follow the programmed velocity command.

This command can be used for adjusting the velocity loop.

By programming the analog outputs to be able to observe variables WV5 and SV2

(Oscilloscope mode) we would obtain on the screen a graph similar to this one:

Tek Hold: 2.5kS/s 130 Acqs --.-- k

0

Ch1 2 V Ch2 2 V 100ms Ch 1 -1.08 V

Actual

Velocity

Command

Period: 160 ms (6.25 Hz)

Amplitude: 600 rpm

Velocity Drive Setup Ver. 0002 SSU - 7

SSU.5.2

SPEED-PI ADJUSTMENT

The Velocity Loop basically consists of a Proportional-Integral (PI) controller shown in the diagram below. The operation of this PI is determined by two constants: Kp and Ti.

From Rotor Sensor

Velocity

Feedback

S V 2

-S 0 0 0 4 0 -

S V 7

-F 0 1 6 1 2 -

Velocity

Command

Final

+

-

K

P

Speed-PI

1

T i

+

+

To

Current Loop

For better system performance, Kp and Ti may be assigned different values depending on the speed of the motor. Usually, a greater proportional and integral factor is preferred when the motor turns slowly. In other words, high Kp and low Ti, as shown below:

S P 1 -S 0 0 1 0 0 -

S P 2 -S 0 0 1 0 1 -

S P 4 -S 0 0 2 1 1 -

S P 5 -S 0 0 2 1 2 -

S P 6 -S 0 0 2 0 9 -

S P 7 -S 0 0 2 1 0 -

Adapter-Speed-PI:

Gain

S P 4 *S P 1

S P 2

S P 5 *S P 2

S P 1

T i

K p

Speed

S P 6 S P 7

The Velocity Loop may be adjusted by using an internal command (previous section) or by using directly the command of the external controlling device.

It is very common to generate a square signal which serves as an internal velocity command and observe the actual speed and the command itself through the analog outputs.

To make the system adjust its performance to a particular external command, it must be applied between pins 4 and 5 of connector X7, (or between pins 2 and 3 of X7 through the auxiliary input).

The following parameters are available for the adjustment: is the integral factor (Ti) of the Velocity Loop. A greater Ti factor

SP1 -S00100- is the proportional factor (Kp) of the Velocity Loop.

SP2 -S00101- is the integral factor (Ti) of the Velocity Loop. A higher Ti factor means a smaller integral effect of the PI.

SP4 -S00111- adapts the value of the proportional action at low speeds.

SP5 -S00112- adapts the value of the integral action at low speeds.

SP6 -S00209is the maximum limit for the speeds considered "low".

SP7 -S00210is the minimum limit for the speeds considered "high".

SSU - 8 Velocity Drive Setup Ver. 0002

For example, if SP4 = 1500 (150%) and SP1 = 30 (0.030 A

RMS

/rpm),

The value for the proportional action Kp at low speeds will be: the 150% of SP1, that is: 0.045 A

RMS

/rpm.

To properly adjust it, the effect of the velocity command filters prior to the PI must be taken into account. This filters are described in the next section.

The next diagram shows the complete internal structure of the Velocity Loop of the DDS.

Depending on the system's response and the type of application, the user changes the PI parameters.

The modifications to these parameters are immediately effective. When the desired performance is achieved, these values must be Saved in the DDS, and then, the unit must be

Reset, (in this order).

To do this, follow the indications detailed in the chapter on "Saving into Flash memory" of this chapter.

Velocity Drive Setup Ver. 0002 SSU - 9

Velocity

Loop

Current

Loop

From Rotor Sensor

S V 2

S V 7

Speed-PI

SP1, SP2,

SP4, SP5,

SP6, SP7.

Current

LP-Filter

CP30

CP31

Out

In

Analog Input 2

X7(3)

X7(2)

P 2

S P 3 1

DS1

IV 2

IP1=2

Voltage/Current

IV 1

S P 3 0

SERCOS

Interface

S P 2 0

S P 2 1 ra tio

Id<>0

Id=0

Id

S V 1

W V 5

WV4=0

W V 4 = 1

ErrorStop OR

SpeedEnable Function

means

PWM_OFF if the motor has not stopped in a time period GP3

Halt Function

SpeedEnable Function

Error Stop

O R

O R

S V 8

P 1

X7(5)

X7(4)

Analog Input 1

WV1, WV2, WV3,

WV4, WV5.

Command Management

Ramps

Jerk

S P 6 0 ...

...S P 6 4

S P 6 0

S P 8 0

Acc. Emerg.

S P 6 5

S P 8 0 = 0

S P 8 0 < > 0

S P 7 0 = 1

S P 7 0 = 0

S P 1 0 0 = 1

S P 1 0 0 = 0

S P 1 0

S V 7

SSU.5.3

VELOCITY COMMAND FILTERS

To smooth motor movement, the velocity command can be "filtered" in two ways described in the following sections. The first one is converting the command into velocity ramps limiting the acceleration "Ramp Generation". The second one is limiting the acceleration and the jerk of the command "Jerk Limit".

These command filters can be eliminated permanently by setting SP100 -F01611- to "0".

In an emergency stop (Halt function, SpeedEnable or Error) the braking deceleration can be limited to a safe value. It is the "emergency acceleration limit".

Halt Function

SpeedEnable Function

Error Stop

O R

O R

S V 8

Ramps

S P 6 0...

...S P 6 4

S P 8 0= 0

Jerk

S P 6 0

S P 8 0

S P 8 0< > 0

ErrorStop OR

SpeedEnable Function

means

PWM_OFF if the motor has not stopped in a time period GP3

S P 1 00 = 1

S P 1 0

S V 7

S P 1 00 = 0

Acc. Emerg.

S P 6 5

S P 7 0= 1

S P 7 0= 0

Velocity Drive Setup Ver. 0002 SSU - 11

SSU.5.3.1

EMERGENCY ACCELERATION LIMIT

To filter the velocity command in an emergency stop, set SP70 -F01610- to "1".

An emergency stop is the one requested by activating the Halt function, by deactivating the

SpeedEnable, or the one due a Drive malfunction.

Emergency Ramp (example):

Halt Function O R

SpeedEnable Function O R

Error Stop

S V 8 -F 0 1 6 1 2 -

S V 7 -F 01 6 1 3 -

S P 6 5 = 1 5 0 0 /0 .1/9 .5 =

1 5 78 ra d /se g 2

1 5 0 0

S P 7 0 = 1

S P 6 5

0

Time

(sec)

0 .1

SSU.5.3.2

RAMP GENERATION

For this type of velocity command filter, set SP80 -S00349- = 0 and SP100 -F01611- = 1

The action of this Ramp Generator is divided into three velocity sections.

In each one of them, the acceleration can be limited to a different value.

From 0 rpm to SP61 Acceleration limited to SP60.

From SP61 to SP63

And from SP63 on

Acceleration limited to SP62.

Acceleration limited to SP64.

Ramps (example):

S P 60 -S 0 01 38- S P 61 -F 016 05 -

S P 62 -F 016 06 - S P 63 -F 016 07 -

S P 64 -F 016 08 -

1 7 5 0

SP6

2

1 0 0 0

5 0 0

0

0

S P

6 0

0 .3 0 .4

S P

6 4

S P 6 3

S P 6 1

Time

(sec)

S P 60= 500 /0 .3/9.5 =17 5 ra d /s e g 2 S P 61 =5 00

S P 62= 750 /0 .1/9.5 =79 0 ra d /s e g 2 S P 63= 175 0

S P 64= 150 ra d /s e g 2 (e g)

S V 8 -F 01 61 2-

S V 7 -F 016 13 -

S P 100= 1

S P 80= 0

Limit set by

SP10 -S00091-

=1900 rpm

Time

SSU - 12 Velocity Drive Setup Ver. 0002

SSU.5.3.3

JERK LIMIT

For this velocity command filter, set SP80 -S00349- other than "0" & SP100 -F01611- = 1.

The jerk is a physical magnitude representing the variation of acceleration in time.

SP80 -S00349- sets the jerk limit. The smaller this parameter is, the more smoothly the motor will run.

SP60 -S00138- sets the maximum acceleration in this operating mode.

Jerk Limit effect:

SP80=700 rad/seg 3 SP80=300 rad/seg 3

SP

60

SP

60

Time

Jerk Limit (example):

1 5 0 0

0

SP80

T

Limit set by SP10

SP

6

0

S P 100= 1

S P 80= 300 ra d /s e g 3

S V 8 -F 01 61 2-

S V 7 -F 01 613 -

Time

SP60

S P 80= S P 6 0/T

Acceleration

Jerk

Time

SP80

Velocity Drive Setup Ver. 0002 SSU - 13

SSU.5.4

REMOVAL OF THE INTERNAL COMMAND

If the adjusting process has been done, the parameters must be saved into the Flash memory and the unit must be reset. The system reset deactivates the command generator.

If only the generator is to deactivated, it could be done by setting the WV4 -F1803- variable to

"0".

SSU - 14 Velocity Drive Setup Ver. 0002

PSU. POSITION DRIVE SETUP

This chapter describes some characteristic aspects for setting up the DDS module when using it as a "Position Drive". The previous SSU chapter describes the necessary steps for setting up a "Velocity Drive".

The last section summarizes step by step the Drive setup procedure.

The "Position Drive" is the result of integrating a "Velocity Drive" and a "position control loop".

Thus, the documentation for the "Velocity Drive" can also be used here.

PSU.1 POSITION LOOP

From software version 04.01 on, the Drive is capable of closing the position loop and, therefore, attend to positioning commands. The position loop consists of a Proportional control and a Feedforward Derivative control. See diagram.

The position feedback may be taken from the motor feedback or from a feedback located on the load (direct feedback).

First of all, the operating mode of the Drive must be determined with parameter AP1 -S32-:

- whether the position feedback is on the motor or on the load.

- the motor feedback will be connected to connector X4 of the drive.

- the feedback signal on the load (direct feedback) will go to connector X3 of the drive.

- whether Feedforward will be applied in the position loop or not.

The position loop also offers a parameter for controlling the ballscrew backlash and, in rotary movement, it can handle the command in module format.

Positioning Drive Setup Ver. 0002 PSU - 1

Halt Function OR SpeedEnable Function OR Error Stop

ErrorStop OR SpeedEnable Function means PWM_OFF if the motor has not stopped in a time period GP3

AP1 -S32- PrimaryOperationMode (bit 3)

PP216 -S296- VelocityFeedForwardPercentage

Not available yet

PP217 -S348- AccelerationFeedForwardPercentage

PP104 -S104- PositionKvGain

PV189 -S189- FollowingError

SV1 -S36- VelocityCommand

SV7 -F1612- VelocityCommandFinal

From Direct Sensor

Ramps Speed-PI

Current

LP-Filter

CP30

CP31

SV2 -S40- VelocityFeedback

From Rotor Sensor

PSU.2 DIRECT FEEDBACK

The position feedback may be mounted directly on the moving load. From now on, this will be referred to as "Direct Feedback".

To work with direct feedback,

- Take the signal to connector X3 of the drive.

- activate bit 2 of parameter AP1 -S32-.

- indicate to the Drive the type of feedback device and the type of signal using these parameters:

GP10 -F234Feedback2Type

NP117 -S117ResolutionOfFeedback2

PP115 -S115PositionFeedback2Type

To work with motor feedback,

- take the signal to connector X4 of the drive.

- deactivate bit 2 of parameter AP1 -S32-.

- indicate to the Drive the type of feedback device and the type of signal using these parameters:

GP2 -F701Feedback1Type

In order for the drive to know the mechanical ratio between the motor movement and the direct position feedback, set the following parameters:

NP121 -S121InputRevolutions

NP122 -S122OutputRevolutions

NP123 -S123FeedConstant

OUTPUT PULLEY

BALLSCREW TABLE

Motor

Motor

Speed

INPUT PULLEY

Speed

Example:

Diameter of the output pulley = 25.75 mm

Diameter of the input pulley = 15.3 mm

NP121 = 2575

NP122 = 1530

Gear ratio =2575/1530 =1.683

Ballscrew pitch = 5 mm

NP123 = 5 milimeters

Positioning Drive Setup Ver. 0002 PSU - 3

PSU.3 PROPORTIONAL CONTROL

It is the basic element of the position loop. Its function at the drive is the same as that of CNC parameter "PROGAIN" (P23) .

Proportional gain setting.

The gain is given at the drive by parameter:

PP104 -S104PositionKvGain

It is given in m/min of programmed velocity command per mm of following error.

Examples:

S104=1 means that to a programmed feedrate of 1000 mm/min (F1000 at the CNC), corresponds a following error of 1 mm.

S104=2 at F1000, the following error will be 0.5 mm.

For a following error of 5 microns at F2000, Kv will be

2/0.005, that is: S104=400

Set this parameter depending on the following error desired for a given feedrate.

Experience shows that most machines behave fine with a proportional gain of S104=1.

PSU - 4 Positioning Drive Setup Ver. 0002

PSU.4 VELOCITY FEEDFORWARD

It is complementary to proportional control. Its function at the drive is identical to that of parameter "FFGAIN" (P25) at the Fagor CNC.

The effect of the anticipated command "Feedforward" helps reduce the following error without increasing the gain, thus maintaining system stability.

Feedforward gain setting

Set up the effect of the velocity Feedforward using this parameter:

PP216 -S296VelocityFeedForwardPercentage

It indicates the portion of the final velocity command that is anticipated to the movement which does not depend on the following error (open loop). The rest of the final velocity command will be due to the proportional gain. See the previous block diagram.

Example:

S296=80 80% of the velocity command comes from the feedforward

20% of the velocity command comes from the proportional effect

The following values can be used as a rule of thumb:

Machines with low machining feedrates between 40 and 60%

Machines with normal machining feedrates between 60 and 80%

Fast machines (laser, plasma) between 80 and 100%

Positioning Drive Setup Ver. 0002 PSU - 5

PSU.5 HOME SEARCH

The "Position Drive" is capable of carrying out an automatic home searching process. This feature is not required in the case of motors with an absolute encoder (ref A0).

PSU.5.1

INCREMENTAL FEEDBACK

This procedure may be activated with the servo system in any initial position. When detecting the "Reference Point" ( ) it ends the procedure and sets the Machine Reference Zero ( ) as the coordinate origin for the following movements in absolute coordinates.

Automatic home searching procedure.

Let us consider here that the parameters correspond to a feedback device mounted on the motor. A later note mentions the parameters corresponding to a direct feedback.

0

It is a random point on machine power-up. Initially, the position feedback PV51 -S51-

(PositionFeedback1) takes that point as coordinate origin.

---- (bH) = before Homing = before executing HOME ----

---- (aH) = after Homing = after executing HOME ----

When executing the HOME instruction, the motor starts turning automatically in search of the reference point with two possible behaviors:

1

2

With the home-switch released PV200 -S400- = 0. Solid line.

With the home-switch pressed PV200 -S400- = 1. dashed line.

Parameters PP41 -S41- (HomingVelocityFast) and PP1 -F1300- (HomingVelocitySlow) set the homing feedrate in each phase of the process.

Speed

S400

I0's

1 0

S51 (bH)

S175

S51 (aH)

S173

S52

S150

F1300 S41

2

Position

PSU - 6 Positioning Drive Setup Ver. 0002

Is the point with the searched marker pulse. When going over that point, which is always done at low feedrate PP41 -S41-, the system registers the value of the position feedback in parameter PV173 -S173- (MarkerPositionA).

PV208 -S408- (ReferenceMarkerPulseRegistered) is activated.

The motor stops.

Is the Machine Zero point for the absolute references. To set the new PV51 -S51-, set PV175 -S175- (DisplacementParameter) by means of the formula: S175 = S52 +

S150 - S173.

PV203 -S403- (PositionFeedbackStatus) is activated.

The internal position command PV47 -S47- (Position Command) is given the value of the new position feedback PV51 -S51-.

Finally, the "Position Drive" remains ready to execute absolute movements.

Warning:

After several home searches in a row, the motor may be left in different final positions.

This is because the braking is not always the same, but "home" has always been found correctly.

Change of the location of point .

Replacing the feedback device or the motor may change the location of the marker pulse. To keep the same home location, set the offset parameter PP150 -S150-. Determine this offset based on a known position in the previous reference system.

Note:

Direct feedback.

When the position feedback is obtained through a direct feedback sensor for the movement (connector X3 of the Drive) some of the parameters mentioned earlier are replaced by their "twins".

Attending to the motor's own feedback:

PP52 -S52- (ReferenceDistance1)

PP150 -S150- (ReferenceOffset1)

PV51 -S51- (PositionFeedback1)

PV175 -S175- (DisplacementParameter1)

Attending to the Direct Feedback:

PP54 -S54- (ReferenceDistance2)

PP151 -S151- (ReferenceOffset2)

PV53 -S53- (PositionFeedback2)

PV176 -S176- (DisplacementParameter2)

Drive parameters ReferenceDistance and ReferenceOffset are equivalent to axis parameters

"REFVALUE" (P53) and "REFSHIFT" (P47) of the 8050/55 CNC.

Positioning Drive Setup Ver. 0002 PSU - 7

Home search setting.

It is possible to set the home searching direction and the boolean logic of the home switch.

Bits 1 and 2 of parameter PP147 -S147- set the positive home searching direction and whether the home switch closes its contacts or opens them when activated.

S400

I0s bit1 S147 = 0 bit0 S147 = 0 bit1 S147 = 1 bit0 S147 = 0

S400

I0s

Pos Pos

S400

I0s bit1 S147 = 0 bit0 S147 = 1 bit1 S147 = 1 bit0 S147 = 1

S400

I0s

Pos Pos

Electrical connection of the "home switch" and parameter setting.

When connecting the electrical contact to one of the digital inputs of the drive.

If no PLC is used, assign variable PV200 -S400- to one of parameters IP10 ... IP13 (in the

Sercos nomenclature, F901 ... F904). Connect the "home switch" to the digital input associated with the chosen parameter.

If a PLC is used, use an instruction to indicate that bit "0" of parameter S400 must take the value of one of the digital inputs (for example I1). The instruction would be: I1 =

B0S400.

When the electrical contact is taken to one of the digital inputs of the 8070 CNC.

The CNC communicates the status of the contact via Sercos; but the Drive is still the one controlling the home search process.

PSU - 8 Positioning Drive Setup Ver. 0002

Mechanical location of the "home switch".

In der to avoid possible repeatability problems when homing, it is recommended to take certain precautions regarding the location of the home switch.

Feedback without marker pulses (reference marks) (E0 on the Fagor motor reference).

In each encoder turn, the load moves a distance L:

L =

NP122

NP121

NP123

At the time when the home search ends, and the motor stops, the position coordinate must be within the ± L/4 margin.

Place the home switch in the load travel point meeting the previous condition

Feedback with marker pulses (E1 or R0 on the Fagor motor reference).

When the gap between the flank of the Home switch and the nearest marker pulse is very small, there could be repeatability problems in the home search.

Move the home switch further away from the reference mark (marker pulse).

Positioning Drive Setup Ver. 0002 PSU - 9

PSU.5.2

LINEAR FEEDBACK WITH DISTANCE-CODED REFERENCE

MARKS

A slight movement of the motor is enough for the Drive to identify the absolute position of the machine.

To carry out this procedure, the feedback device must be identified using the following parameters.

NP117 -S117- ResolutionOfFeedback2

NP118 -S118- ResolutionOfLinearFeedback

NP165 -S165- DistanceCodedReferenceMarksA

NP166 -S166- DistanceCodedReferenceMarksB

S166 S166 S166

S165 > S166

S165 S165 S117 S165

For example, Fagor steel tape scales have several reference marks separated 100 signal cycles, the group of marks alternating with the previous ones are separated 100.1 signal cycles and their resolution is 10 microns.

Let us suppose that in this particular scale model and using a multiplying factor of x10, an accuracy of 1 micron is obtained. The values to be assigned to these parameters are:

S117 = 20 microns

S165 = 1001

S118 = 2 microns

S166 = 1000

To operate with this type of feedback, set the following bits:

5, 3, 1 and 0 of PP115. Proceed as follows:

• PP115 (bit 0) = 1

• PP115 (bit 1) = 1

• move the axis in the direction to be set as positive; if the position coordinate decreases, invert the value of PP115 (bit 3).

• Do a home search, move the axis in the positive direction and do a home search again, if the coordinate given after the second home search is smaller than the one given in the first one, invert the value of PP115 (bit 5).

PSU - 10 Positioning Drive Setup Ver. 0002

The manufacturing of linear scales with distance-coded reference marks causes each feedback device to have a different zero point. To set the coordinate origin at a particular point of their travel, proceed as follows:

• Do a home search.

• Move the axis to the point selected as zero.

• Reed the PV53 -S53- PositionFeedback2 variable

• Set parameter PP178 -S178- AbsoluteDistance2 to the value read in PV53.

Fagor scales have the following characteristics:

FOP

FOS

FOT

FOX

MOVC

MOVP

MOVS

MOVX

MOVY

Type

COC

COVC

COVP

COVS

COVX

COX

FOC

Feedback signal period

20 micr

20 micr

20 micr

20 micr

4 micr

4 micr

100 micr

100 micr

100 micr

20 micr

4 micr

20 micr

20 micr

20 micr

4 micr

2 micr

Distance between I0s

10 mm

10 mm

10 mm

10 mm

10 mm

10 mm

50 mm

50 mm

50 mm

50 mm

50 mm

10 mm

10 mm

10 mm

10 mm

10 mm

Incremental distance between I0s

20 micr

20 micr

20 micr

20 micr

20 micr

20 micr

100 micr

100 micr

100 micr

100 micr

100 micr

20 micr

20 micr

20 micr

20 micr

20 micr

To calculate the values to be given to the parameters:

NP166 =

(Distance between I0s) x 2

(Increment distance between I0s)

NP117 = Feedback signal period

NP165 =

(Distance between I0s) x 2 + (Incremental distance between I0s)

(Incremental distance between I0s)

Thus, for example:

Fagor FOP feedback:

50 · 2

NP166 = = 1000

0.1

NP117 = 100 microns

50 · 2 + 0.1

NP165 = = 1001

0.1

In fact all Fagor scales appearing in this table are adjusted with NP166 = 1000 and NP165 =

1001.

Positioning Drive Setup Ver. 0002 PSU - 11

PSU.5.3

ABSOLUTE FEEDBACK

The absolute feedback on Fagor FXM motors registers the value of their angular position along more than 4000 turns and it does not lose it when turning the machine off. Thus, the drive knows from the very first instant which is the absolute position of that axis.

To place the machine zero at a particular point of the axis travel, proceed as follows:

• Take the axis to the point selected as zero.

• Read the PV51 -S51- PositionFeedback1 variable

• Set parameter PP177 -S177- AbsoluteDistance1 with the value read in PV51.

PSU.6 BALLSCREW BACKLASH COMPENSATION

When the position feedback is obtained on the motor shaft, the ballscrew backlash must be compensated for.

Feedback on the motor.

The drive can compensate for any backlash between the load and the ballscrew by internally acting upon the position command. Thus correcting the movement hysteresis originated when reversing the direction of the axis.

Set this parameter:

PP58 -S58Backlash

This ballscrew backlash compensation only takes place if:

• the Drive is in position control mode and

• there is no feedback on the load.

Warning: Both the drive and the CNC offer parameters setting the value of ballscrew backlash. This value must ONLY be registered AT ONE OF THEM. The other parameter must be set to "0".

Load

Ball-screw

Backlash

PSU - 12 Positioning Drive Setup Ver. 0002

PSU.7 FOLLOWING ERROR MONITORING

The monitoring of following error prevents the axes from running away.

The drive compares these parameters:

PV189 -S189-

PP159 -S159-

FollowingError

MonitoringWindow

If FollowingError > MonitoringWindow means that the servo system follows the command with an excessive delay and it triggers the error message:

Error 205 ExcessivePositionDeviation (DV1 -S11-, Bit 11)

This monitoring of the Following Error is only done if:

• if the drive is in position control mode, (see AP1 -S32-)

• parameter MonitoringWindow is other than zero, PP159 > 0 and

• there is motor torque, TV100 -F1702- = 1.

If parameter PP159 -S159- MonitoringWindow is "zero", the following error will not be monitored. It is very important to set it to a value other than zero to prevent the axes from running away out of control.

The CNC also monitors the maximum amount of following error allowed by indicating in its relevant parameter in the parameter table for each axis at the CNC.

Position an d

Comm

Act ua l

Following error

Time

Following error

Monitoring window

Time

Positioning Drive Setup Ver. 0002 PSU - 13

PSU.8 MODULE FORMAT

The "drive" can work in "module format". This is format mainly used on rotary axes.

This means that it is ready to handle the full mechanical travel of the axis by means of command or feedback data restricted to a range of values; usually between 0 and 360.

This range of values is set by parameter:

PP103 -S103ModuloValue

The drive uses bit 7 of the following parameter for selecting the "module" or "absolute" configuration format.

PP76 -S76PositionDataScalingType

Modulo Format Command

360°

Command

360°

Absolute Format

Turn

Turn

Working in Module format, the Drive does not admit:

• commands in absolute value greater than PP103

• increments greater than half PP103 between consecutive position commands.

Verify that the CNC defines that axis the same way (module or linear format).

PSU - 14 Positioning Drive Setup Ver. 0002

PSU.9 STARTUP SUMMARY

General parameters

AP1: Selects the operating mode of the drive.

= 3: Position loop using motor feedback without Feedforward.

= 4: Position loop using direct feedback without Feedforward.

= 11: Position loop using motor feedback with Feedforward. (PP216)

= 12: Position loop using direct feedback with Feedforward. (PP216)

GP10: Direct feedback signal type.

= 0 There is no direct feedback.

= 1 Square TTL signal

= 2 "1Vpp" sinewave signal or differential square TTL signal.

Check the value taken by the parameter:

GP2: Motor feedback type.

= 0 Sinewave encoder

= 1 Resolver.

= 2 Squarewave TTL encoder.

= 5 Heidenhain encoder (ERN 1387) for Siemens motors, 1FT6 family.

When using motor feedback (AP1=3 or AP1=11)

The following parameters are ignored:

GP10: Direct feedback signal type.

PP54: Refvalue with direct feedback.

PP115: Direct feedback parameter setting.

NP117: Pitch/pulses setting for direct feedback.

When using external feedback (AP1=4 or AP1=12)

The following parameters are ignored:

PP150: Refshift for motor feedback.

PP52: Refvalue with motor feedback.

Resolution related parameters:

PP115: External feedback parameter setting.

Bit 5: Structure of distance coded feedback

= 0 counting positive with positive direction

= 1 counting negative with positive direction

Bit 3: Direction polarity

= 0 not inverted

= 1 inverted

Bit 1: Feedback type

= 0 rotational feedback. See NP117.

= 1 lineal. See NP118.

Bit 0: Direct feedback type:

= 0 Rotary (encoder), (NP117 will give pulses per turn).

= 1 Linear (scale), (NP117 will give the period of the scales feedback signal).

NP117: Resolution of the rotary direct feedback in pulses per turn.

NP118: Resolution of the linear direct feedback.

- period of the scale signal. 20 microns for Fagor scales (graduated glass), S118 = 20 microns.

NP121, NP122: The "NP121/NP122" ratio indicates the gear ratio between the motor and the ballscrew.

They only admit integer values up to 32767.

NP123: Ballscrew pitch. If it is a rotary axis, set NP123 = 360000.

Parameters to identify a linear feedback with distance-coded reference marks:

NP165: Distance between reference marks.

NP166: Distance between "coded" reference marks.

Positioning Drive Setup Ver. 0002 PSU - 15

Home search parameters.

PP147: Setting of the home search.

Bit 5: = 0 The home switch is monitored (by default)

= 1 The home switch is ignored

Bit 3: = 0 Motor feedback (see PP52, PP150)

= 1 Direct feedback (see PP54, PP151)

Bit 1: = 0 Home switch normally open.

= 1 Home switch normally closed.

Bit 0: = 0 The motor shaft turns clockwise when searching home.

= 1 The motor shaft turns counterclockwise when searching home.

With the 8070 CNC take the electrical contact "home switch" to one of its digital inputs.

PP1: Slow motor speed when the home search is controlled by the Drive itself.

PP41: Fast motor speed when the home search is controlled by the Drive itself.

PP42: Acceleration of the movements when searching home.

PP52: Machine reference point position (home) with respect to Machine Reference Zero (Refvalue motor feedback).

PP54: Machine reference point position (home) with respect to Machine Reference Zero (Refvalue direct feedback).

Parameters PP52 and PP53 of the drive are equivalent to the "REFVALUE" (P53) of the 8050/55 CNC axis.

PP150: Position of the reference mark with respect to the machine reference point (home) (Refshift motor feedback).

PP151: Position of the reference mark with respect to the machine reference point (home) (Refshift direct feedback).

Parameters PP150 and PP151 of the drive are equivalent to axis parameter "REFSHIFT" (P47) of the

8050/55 CNC except that the Drive does not move to return to the "REFVALUE" (P53) position.

Homing method. The home switch may be connected directly to the PLC or to the drive, this is now irrelevant.

Gain related parameters.

PP104: Proportional gain in the position loop. It is similar to axis parameter "PROGAIN" (P23) of the 8050/55

CNC. PP104=1, means a following error of 1 mm at F1000 mm/min.

PP216.#: % of velocity FeedForward (0 to 100%). It is similar to axis parameter "FFGAIN" (P25) of the 8050/

55 CNC

PP159: Maximum amount of following error permitted. If this parameter is set to "0", the following error is not monitored. It is very important to set it to a value other than "0" to prevent the axes from running away out of control. At the CNC the maximum following error permitted is also watched. This value is indicated in its relevant parameter in the parameter table for each axis at the CNC.

PV 189: Monitoring of the following error.

PSU - 16 Positioning Drive Setup Ver. 0002

Various parameters for the position loop.

PP49, PP50: Indicate the maximum position that can be reached by the servo system in both positive and negative directions respectively. These limits are observed only when all the position data is referred to

Machine Reference Zero. That is, Bit 0 of PV203 -S403- PositionFeedbackStatus is set to "1".

If the variable PV58 -S258 TargetPosition exceeds the position limits, the drive will activate bit 13 of

DV9 -S12- Class2Diagnostics (Warnings) TargetPositionOutsideTheTravelZone.

The CNC also observes the travel limits defined in its axis parameter tables.

PP55: Controls the polarity of various position data.

Bit 4: Position limits

= 0 active (by default). See PP49 and PP50.

= 1 cancels the position limits.

Bit 3: Direct position feedback value

= 0 non-inverted

= 1 inverted (by default)

Bit 2: Motor position feedback value

= 0 non-inverted

= 1 inverted (by default)

Bit 0: Position commandvalue

= 0 non-inverted

= 1 inverted (by default)

PP58: Ballscrew error. With motor feedback, the drive compensates for the backlash in changing direction.

Both the drive and the CNC offer parameters to set the value of the ballscrew backlash; but this value must only be registered in either one of them. The other parameter must be set to "0".

PP76: Command application in module format. Verify that the CNC defines that axis the same way (module or absolute format).

Bit 7: = 0 The module format is not applied.

= 1 The module format is applied to the axis.

PP103 : Value of the module to be applied on to rotary axes that do not work as linear axes (usually 360º).

QP1 : Loop cycle time. Read-only parameter that indicates how often the loop is being closed at the drives.

Parameters to be used only in Motion Control applications.

PP57: In-position zone. It indicates the difference allowed between the real and final position

(PV58 -S258- TargetPosition) for considering that the axis is in position.

Positioning Drive Setup Ver. 0002 PSU - 17

User notes:

PSU - 18 Positioning Drive Setup Ver. 0002

AP. APPLICATIONS

This chapter describes some particularities of the Servo Drive system:

- Considerations for the system start-up with Sercos interface.

- Adjustment of the motors for spindle at low rpm.

- Motor locking function, Halt.

- Monitoring the drive's internal variables.

- Set of Parameters and Gear Ratios.

- Spindle overload detection.

Important:

The features documented in this chapter need the following software versions:

8050/55 CNC versions V13.02 (mill) and V12.01 (lathe).

Drive versions V03.01 and later.

AP.1

SERCOS CONNECTION WITH THE 8050/55 CNC

Sercos is a communications standard designed especially for the machine-tool industry and simplifies the connection between CNCs and servo drives of different manufacturers.

All the data and commands are transmitted in digital format through fiber optic lines. These lines form a ring interconnecting all the electronic elements forming a system (CNC and servo drives).

The Drives with Sercos interface carry special connections for the fiber optic lines with the display and their sales reference is SI, and S0, for example, AXD1.25.SI.0, SPD2.75.S0.0

The Sercos interface reduces considerable the needed hardware and simplifies the cabling making the system more robust since it improves its immunity to electrical noise.

See chapter IN of this manual.

Sequence of start-up operations

- Connection of the fiber optic lines and identification of the Drives.

- Parameter setting at the CNC 50/55.

- Description of the manoeuver at the PLC 50/55.

- Parameter setting at the Drives.

- Powering the machine up again.

- Troubleshooting

Applications Ver. 0002 AP - 1

AP.1.1

CONSIDERATIONS AT THE 8050/55 CNC

When using the Sercos interface, the Drives must be identified in the ring and determine the operation mode.

Certain CNC 50/55 and Drive parameters must also be set.

AP.1.1.1

IDENTIFICATION AND OPERATION MODE

The following CNC parameters must be set for each servo drive.

SERCOSID

Function:

Possible values:

Example:

(Parameters: P056 for the axes, P044 for the spindles, P044 for the auxiliary spindle)

Identifies each Drive in the Sercos ring. Its value must match the selection at the

Node_Select switch.

0 The Drive is "transparent" in the communications within the ring; but it is not recognized as one of its elements.

1..8

The Drive is identified in the ring with the SERCOSID element number , and will have all the features of the Sercos interface.

See illustration.

SERCOSLE

Function:

Possible values:

(Parameters: P063 for the axes, P051 for the spindles)

Determines the feedback source at this servo drive system. In other words, if the

CNC receives the feedback from that servo system through its connector at the axes module or through the Sercos interface. In either case, the velocity command is sent out to the drives via Sercos.

0 (Mode 0) The servo system has an encoder or scale outside the motor and the CNC 50/55 receives the signals through the corresponding

1 connector at its axes module.

(Mode 1) The CNC 50/55 receives the feedback position from the Drive through the Sercos ring. This Drive has generated that signal based on the motor feedback itself.

Important:

The value of the SERCOSID parameter must match the address selected with the

"Node Select" switch at the Drive module.

Remember that the numbers must be correlative and starting from One.

If the same motor is to be used as "C axis" and as spindle, the SERCOSID parameter of both CNC 50/55 tables must have the same value.

The servo drive identified as number 1 (for example) does not have to correspond to the X axis, the Y axis to another and so on. However, it would be much simpler to make the axes of the machine X, Y, Z, U, V, W, A, B and C follow a sequential numbering system. The diagram below shows an example.

AP - 2 Applications Ver. 0002

Use to parameter SERCOSLE to select the communications line for feedback signals which means two work modes well differentiated. They are described in the following sections..

AP.1.1.1.1

8050/55 in "0" mode (external feedback)

The CNC receives the position feedback through its connector at the axes module.

The velocity command is sent out to the Drive through the fiber optics given in rpm and referred to the motor.

Drive

Motor Speed

Command

Sercos

Power

Motor

Feedback

Motor

CNC

50/55

Motor

Speed

Speed

Feedback

Speed

AP.1.1.1.2

8050/55 CNC in "1" mode (motor's own feedback)

The CNC receives the position feedback through the fiber optic lines of the Sercos ring.

This feedback is generated by the Drive based on the feedback of the motor itself.

The velocity command is sent out to the Drive through the fiber optics. It is in rpm and referred to the motor.

Drive

Motor Speed

Command

Sercos

Speed

Feedback

Power

Motor

Feedback

Motor

CNC

50/55

Motor

Speed

Speed

Applications Ver. 0002 AP - 3

AP.1.1.2

OTHER 8050/55 CNC PARAMETERS

The analog velocity command at the 8050/55 CNC is adjusted by means of parameters

PROGAIN, FFGAIN, DERGAIN, ACFGAIN, MAXVOLT, MAXVOLT1...4.

PROGAIN (PROportional GAIN) (Parameters: P023 for axes and spindles)

Function: Proportional gain. It is the constant that sets the ratio between the velocity command and the following error (axis lag). The main component of the Velocity Command is proportional to the Following error and to this parameter PROGAIN. It must be adjusted.

Axes: PROGAIN indicates the mV of velocity command desired for a following error of 1 mm.

Spindle: PROGAIN indicates the mV of velocity command for a following error of 1º.

Only when the spindle is working in M19 mode or Rigid Tapping.

0..65535 mV/mm (1000 mV/mm by default), or in mV/degree for the spindle.

Possible values:

DERGAIN (DERivative GAIN) (Parameters: P024 for the axes and spindles)

Function:

Possible values:

Derivative gain. It gives an additional component to the Velocity Command.

Its function depends on the value of another parameter (ACFGAIN):

If ACFGAIN=NO

DERGAIN is the constant that sets the ratio between the Velocity Command and the variation of the Following Error every 10 milliseconds.

If ACFGAIN=YES

DERGAIN is the constant that sets the ratio between the Velocity Command and the variation of speed every 10 milliseconds.

If for example ACFGAIN=NO, then:

Axes: DERGAIN indicates the mV of command corresponding to a variation of following error of 1mm in 10 ms.

Spindle: DERGAIN indicates the mV of command for a change of 1º of following error in 10 ms. Only when the spindle is working in M19 mode or Rigid Tapping.

0..65535 mV/(mm/10ms) (0 mV/(mm/10ms) by default).

FFGAIN (Feed Forward GAIN)

Function:

Possible values:

(Parameters: P025 for axes and spindles)

Axes: defines the percentage of additional command due to the programmed feedrate.

Spindle: defines the percentage of additional command due to the programmed speed. Only when the spindle is working in M19 mode or Rigid Tapping.

0..100 (0 by default)

ACFGAIN (AC-Forward GAIN)

Function:

Possible values:

(Parameters: P046 for the axes, P042 for the spindles)

Determines whether the axis machine parameter DERGAIN is applied to the variations in following error or to the variations of the programmed feedrate. See

DERGAIN function.

No: on following error

Yes: on variation of programmed speed

MAXVOLT (MAXimum VOLTage) (Parameter: P037 for the axes)

Function:

Possible values:

Indicates the value of the analog voltage of velocity command for G00FEED.

0...9999 mV (9500 mV by default)

On axis drives when working with Sercos interface, this parameter must always be set to 9500.

MAXVOLTn (MAXimum VOLTage gear n) (Parameters: P037...P040 for n=1...4 at the spindles)

Function:

Possible values:

Indicates the value of the analog voltage of velocity command for the maximum speed of the gear n.

0...9999 mV (9500 mV by default)

These parameters are described in chapters three and four of the installation manual of the

8050/55 CNC.

AP - 4 Applications Ver. 0002

These parameters and the way to calculate them are also applicable to generate the digital

Sercos velocity command.

This command is transmitted through fiber optics in motor rpm.

This command conversion from a mV to a digital command requires some parameters to be sent at the CNC as well as at the Drive. The following sections show how to se them.

AP.1.1.2.1

On Axis drives

The CNC communicates to the Drive and through the Sercos ring the desired motor speed in rpm (MS) calculated as follows:

G00FEED

MS =

[

444 2 mV

444 3

]

×

MAXVOLT

1

×

NP123

×

NP121

(rpm motor)

NP122

NP121 -S00121-, NP122 -S00122- and NP123 -S00123- are parameters of the drive.

Thus, for a proper setup of the system, proceed as follows:

At the drive:

- Set parameters NP121, NP122 and NP123 according to the gear ratios installed.

- SP20 -F00031- and SP21 -F00081- are ignored.

At the CNC:

- Set MAXVOLT = 9500 that is: 9.5 volts.

- Calculate the PROGAIN constant based on a command of 9500 mV. Thus:

PROGAIN

=

9500

EdS

=

G00FEED

(mV / mm) where:

EdS (mm) = following error at G00FEED.

Kv is a constant indicating the ratio between G00FEED and the EdS. Thus: for Kv=1, the EdS (following error) will be 1 mm for a feedrate of 1 m/min.

for Kv=2, the EdS (following error) will be 0.5 mm for a feedrate of 1 m/min.

Feedback parameter setting at the axis drive:

With SERCOSLE=0

Using external feedback requires that all the feedback parameters to be set at the CNC:

PITCH (P007), NPULSES (P008), DIFFBACK (P009), SINMAGNI (P010),

FBACKAL(P011), REFPULSE (P032), IOTYPE (P052), ABSOFF (P053) and

EXTMULT (P057). They are located in the parameter table for each axis a the 8050/55

CNC.

With SERCOSLE=1

The Drive indicates the motor speed to the CNC 50/55 by means of digital commands through Sercos. Therefore, the feedback characteristics will be set by the parameters of the Drive. At the CNC 50/55, the parameters mentioned earlier are ignored.

Applications Ver. 0002 AP - 5

AP.1.1.2.2

On spindle drives in open loop.

The CNC 50/55 indicates to the spindle drive, through the Sercos ring, the desired motor speed in rpm (MS) which is calculated as follows:

MS

=

ProgrammedSpeed

1 44444 2

⋅ mV

MAXVOLTn

SP21

(motor rpm)

SP20

To properly setup the drive, proceed as follows:

At the Drive:

- Set parameters SP20 -F00031- and SP21 -F00081- with the maximum motor speed for this application and 9500 millivolts respectively.

- Set NP121 -S00121-, NP122 -S00122- and NP123 -S00123- when wishing to display the tool speed on the screen while working with SERCOSLE=1.

At the CNC 50/55:

- Set the CNC 50/55 MAXGEARn parameters with the maximum tool speed for that gear

"n".

- Set the MAXVOLTn parameters according to the following equation:

MAXVOLTn

= 1 4 2 ⋅ motor rpm

SP20

SP21

(mV)

Ratio = Gear Ratio =

N motor

N tool

Example of open loop spindle

A machine has three gear ratios: 4/1, 2/1 and 1/1. The maximum motor speed is 4000 rpm and the maximum tool speeds are: 1000, 2000 and 3800 rpm in each.

Therefore, proceeding as indicated earlier:

SP21 -F00081- = 4000, and

SP20 -F00031- = 9500.

MAXGEAR1 = 1000 rpm,

MAXGEAR2 = 2000 rpm, and

MAXVOLT1

=

1000

MAXGEAR3 = 3800 rpm.

The MAXVOLTn parameters will be:

MAXVOLT2

=

2000

MAXVOLT3

=

3800

1

1

1

9500

4000

(mV) = 9500 mV

9500

4000

(mV) = 9500 mV

9500

4000

(mV) = 9025 mV

Feedback parameter setting at the spindle drive in open loop:

With SERCOSLE=0

Using external feedback requires all the feedback parameters to be set at the CNC 50/55:

NPULSES (P013), DIFFBACK (P014), FBACKAL(P015) and REFPULSE (P032).

With SERCOSLE=1

The Drive indicates the motor speed to the CNC 50/55 by means of digital commands through Sercos. Therefore, the feedback characteristics will be set by the parameters of the Drive. At the CNC 50/55, the parameters mentioned earlier are ignored.

AP - 6 Applications Ver. 0002

AP.1.1.2.3

On spindle drives in closed loop, M19 or Rigid Tapping.

The CNC indicates to the drive, through the Sercos ring, the desired motor speed (MS) which is calculated in a way similar to that of the axis drive.

MS

=

[

444 2 444 3

] mV

SP21

(motor rpm)

SP20

To properly set the drive, proceed as follows:

At the Drive:

- Set parameters SP20 -F00031- and SP21 -F00081- with the maximum motor speed value for this application and 9500 millivolts respectively.

- Set parameters NP121, NP122 and NP123 according to the gear ratios installed.

At the CNC 50/55:

- Set the MAXGEARn parameters of the CNC 50/55 with the maximum tool speed value for that gear "n".

- Set the MAXVOLTn parameters according to the equation shown in the previous section.

And:

At the CNC 50/55:

- The constants PROGAIN, DERGAIN, etc. must also be set. For example:

Two CNC 50/55 parameters:

REFEED1 (P034) = Maximum angular speed in M19 (°/min).

REFEED2 (P035) = Maximum angular speed of the tool when searching home in M19.

and two concepts similar to MaxGear and MaxVolt used earlier:

MG_M19 = Maximum tool turning speed in M19 (rpm).

MV_M19 = Analog voltage for REFEED1 (mV).

Hence, PROGAIN is calculated as follows:

PROGAIN

=

MV_ M19

EdS

= where:

REFEED1

MAXVOLT1

MV_ M19 =

MAXGEAR1

REFEED1

(mV)

360 and and where:

EdS (mm) = Following error at a speed of REFEED1.

Kv is a constant indicating the ratio between REFEED1 and the EdS, Thus: for Kv=1 the EdS will be 1° for a speed of 1000 °/min.

for Kv=2 the EdS will be 0.5° for a speed of 1000 °/min.

The next page shows an example.

Applications Ver. 0002 AP - 7

Example for a spindle in closed loop:

Using the example for a spindle in open loop, we have:

The machine has three gear ratios: 4/1, 2/1 and 1/1.

Maximum motor speed for this application: 4000 rpm.

SP21 -F00081- = 4000, and SP20 -F00031- = 9500.

MAXGEAR1 = 1000 rpm, MAXGEAR2 = 2000 rpm y MAXGEAR3 = 3800 rpm.

MAXVOLT1 = 9500 mV, MAXVOLT2 = 9500 mV, MAXVOLT3 = 9025 mV.

And:

The maximum tool speed in this mode is: 100 rpm.

The maximum tool speed when searching home is 50 rpm.

The following error must be 1° for every 1000°/min. (Kv=1)

A gear ratio of "1" is the right one to work with spindle orientation (M19), since

MAXGEAR1 is the next value up from the 100 rpm foreseen for M19.

Therefore:

MV_ M19 =

9500

1000

36000

360

=

950mV

PROGAIN

=

360000

=

950

36

=

Parameter PROGAIN does not admit decimals. Therefore, in this example, in order to keep accuracy, we can use another parameter to change the units for PROGAIN:

When GAINUNIT (P041) is equal to 0, we will set PROGAIN = 26

When GAINUNIT (P041) is equal to 1, will set PROGAIN = 2638

These can be found in the spindle parameter table of the 8050/55 CNC.

AP - 8 Applications Ver. 0002

Feedback parameter setting at the spindle drive in closed loop:

With SERCOSLE=0

Using external feedback requires all the feedback parameters to be set at the CNC 50/55:

NPULSES (P013), DIFFBACK (P014), FBACKAL(P015) and REFPULSE (P032).

With SERCOSLE=1

When no external encoder is used, the motor encoder may be used by setting

SERCOSLE=1 at the CNC 50/55. At the drive, the existing gear ratios must be set by means of GP6 -F00717-, NP121 -S00121-, NP122 -S00122- and NP123 -S00123-.

At the CNC 50/55, the feedback parameters mentioned earlier are ignored.

Important:

When working with SERCOSLE=1, the motor feedback is only useful to work in M19 mode and/or Rigid Tapping when the spindle only has one gear and the Gear Ration meets one of these two conditions:

- The Gear Ratio is 1/1. The Reference mark of the spindle (I

0 feedback.

) is that of the motor

- The Gear Ratio is of the n/1 type where "n" is an integer (no decimals). In this case, a microswitch must be used for selecting a particular reference pulse among the "n" signals generated by the motor encoder per spindle turn.

Applications Ver. 0002 AP - 9

AP.1.2

CONSIDERATIONS AT THE DRIVES

When using the Sercos interface, certain Drive parameters are no longer needed.

If neither the "Encoder Simulation" nor the "I/O" boards are installed, their associated parameters are not needed either.

Parameters NP121 -S00121-, NP122 -S00122- and NP123 -S00123- must be properly set in the following cases:

- At the axis drives, ALWAYS.

- At the spindle drives, when wishing to display tool speed or to work in closed loop (M19 or Rigid Tapping) while working with motor feedback (SERCOSLE=1).

At the spindle drives with external feedback (SERCOSLE=0) the NP parameters need not be set.

SP20 -F00031- and SP21 -F00081- must be set:

- At the spindle drives, ALWAYS. Set them with the maximum motor speed values for that application and 9500 millivolts respectively.

- They need not be set at the axis drives.

Example for setting parameters NP121, NP122 and NP123:

If for every 5 turns of the motor shaft, the ballscrew turns 3 times. The parameters must be set as follows:

NP121 = 5 NP122 = 3

If it is a linear axis where for each ballscrew turn, the table moves 4 mm:

NP123 = 40000 tenths of a micron.

If it is a rotary axis where each turn of the output pulley means a 360º turn:

NP123 = 3600000 ten-thousandths of a degree.

For example:

OUTPUT PULLEY

BALLSCREW TABLE

Motor

Motor

Speed

INPUT PULLEY

Speed

Example:

Diameter of the output pulley = 25.75 mm

Diameter of the input pulley = 15.3 mm

NP121 = 2575

NP122 = 1530

Gear ratio =2575/1530 =1.683

Ballscrew pitch = 5 mm

NP123 = 5 milimeters

AP - 10 Applications Ver. 0002

AP.1.3

CONTROL SIGNALS PLC8050/55 - DRIVE

Signals from the PLC 50/55 to the Drive.

The Drive "Speed Enable" and "Drive Enable" can now be controlled from the PLC 50/55 through the Sercos ring. To do that, the PLC 50/55 now offers two new output logic variables:

SPENAn (SPeed ENAble n) (n=1..7) (M5110, M5160, M5210, M5260, M5310, M5360 and M5410)

SPENAm (SPeed ENAble m) (m=S,S2,AS) (M5462, M5487and M5449)

Function:

Possible values:

Identifies the electrical signal "Speed Enable" of connector X2 of the Drive.

0 Disables the velocity command. Motor with command zero.

1 Enables the velocity command. The motor follows the command.

DRENAn (DRive ENAble n) (n=1..7) (M5111, M5161, M5211, M5261, M5311, M5361 and M5411)

DRENAm (DRive ENAble m) (m=S,S2,AS) (M5463, M5488 and M5448)

Function:

Possible values:

Identifies the electrical signal "Drive Enable" of connector X2 of the Drive.

0 Disables the Drive. The motor has no torque.

1 Enables the Drive.

The "Speed Enable" function at the drive will be activated when the SPENA variable is activated and the electrical signal Speed_Enable is activated at the pins of connector X2.

The "Drive Enable" function will be activated when the DRENA variable is activated and the electrical signal Drive_Enable is activated at the pins of connector X2. See diagram below.

Safety regulations (EN-60204-1) demand the Drive Module to have an input non-software related to guarantee that the motor will stop.

The hardware control over the electrical signal "Drive_Enable" MUST

NOT be removed even when using the Sercos interface.

O R

S p e e d E n a b le

F u n c tio n

S p e e d E n a b le P in

S p e e d E n a b le (S e rc o s )

-S P E N A -

(X 2 )

D V 3 2 -S 1 3 4 -

(b it 1 5 )

D riv e E n a b le P in

D riv e E n a b le D n c

D riv e E n a b le (S e rc o s )

-D R E N A -

H a ltD riv e P in

H a ltD riv e D n c

H a lt (S e rc o s )

(X 2 )

B V 7 -F 2 0 3 -

D V 3 2 -S 1 3 4 -

(b it 1 4 )

B V 1 -F 2 0 1 -

B V 3 -F 2 0 2 -

D V 3 2 -S 1 3 4 -

(b it 1 3 )

O R

D riv e E n a b le

F u n c tio n

O R

H a lt F u n c tio n

Applications Ver. 0002 AP - 11

Signals from the Drive to the PLC 50/55.

The Drive offers two bits to the PLC 50/55 to indicate the operating status.

These are: DRSTAFn and DRSTASn. The table below shows the meaning of these signals.

DRSTAFn (DRive STAtus First n) (n=1..7,S,S2,AS) (M5603, M5653, M5703, M5753, M5803, M5853 and M5903 at the axes. M5953, M5978 and M5557 at the spindles)

DRSTASn (DRive STAtus Second n) (n=1..7,S,S2,AS) (M5604, M5654, M5704, M5754, M5804,

M5854 and M5904 at the axes. M5954, M5979 and M5556 at the spindles)

Function:

Possible values:

They are the bits indicating the Drive status to the PLC. This way, the PLC program will handle the drive control signals depending on its status.

0,1 with the meaning explained in the next table.

Important:

As a general rule, the PLC assigns the id numbers to all the axis variables in the following order: X, Y, Z, U, V, W, A, B and C. The SERCOS id numbers (SERCOSID,

Node_Select) assigned to the drives have nothing to do with this.

If the machine has three axes (for example: X,Y,B):

Variables SPENA1, DRENA1, and bits DRSTAF1 and DRSTAS1 will correspond to the X axis, those with the index 2 to the Y axis and those of the index 3 to the B axis.

Those with the S, S1 and AS index will correspond to the main, second and auxiliary spindle respectively.

The installation manual of the 8050/55 also mentions these PLC variables.

DRSTAFn

0

0

1

1

DRSTASn

0

1

0

1

Status Action

The Drive is not ready. Do not apply Mains power to the

Power Supply.

The Drive is ready to receive Power at the Bus. The

Drive_OK contact is closed.

The Drive is ready to attend to the control signals.

Check the 24 Vdc, and/or solve the errors.

Apply Mains power to the Power

Supply.

Enable the Drive with Drive_Enable and Speed_Enable.

The Drive_Enable and Speed_Enable functions activated.

The motor follows the command.

Govern the motor with the command.

AP - 12 Applications Ver. 0002

This is an example of how to program a Fagor PLC.

It handles the drive's control signals depending on its status and other variables.

;----- This machine has two axes (X, Z) an a spindle (S)

;----- The Z axis is vertical and it is not compensated. It has a brake controlled by the O20 output.

;----- DRIVE STATUS MANAGEMENT -----

DRSTAF1 = B1R101

DRSTAS1 = B0R101

;

DRSTAF2 = B1R102

DRSTAS2 = B0R102

;

DRSTAFS = B1R103

;

DRSTASS = B0R103

CPS R101 GE 1 = M101

CPS R102 GE 1 = M102

CPS R103 GE 1 = M103

M101 AND M102 AND M103 = M123

;X axis drive status

; Z axis drive status

;Spindle drive status

;X axis drive OK

;Z axis drive OK

;Spindle drive OK

;All the drives are ready

;the machine can be powered up

;----- MANAGING EMERGENCIES -----

M123 AND I1

AND (other conditions) = /EMERGEN

/EMERGEN AND /ALARM

AND (other conditions) = O1

;----- MANAGING AXES ENABLES -----

CPS R101 GE 2 = M111

CPS R102 GE 2 = M112

M111 AND M112 = M133

M111 AND NOT LOPEN AND O1

AND (others) = SERVO1ON = SPENA1

= TG3 1 300

T1 = DRENA1

;Emergency inputs

;Emergency output

;The X axis has power

;The Y axis has power

;All the axis drives OK and with power

;X axis enable

;Speed Enable for the X axis

M112 AND NOT LOPEN AND O1 AND (others)

= TG3 2 400 = O20

T2 = DRENA2 = SERVO2ON = SPENA2

;Drive Enable with a 300ms delayed deactivation

; for emergency stops.

;Z axis (vertical) enable

;Brake controlling signal

;Speed and Drive Enable with a 400 ms delayed

; deactivation to prevent axis sag.

;----- MANAGING SPINDLE ENABLES -----

CPS R103 GE 2 = M113 ;The spindle drive has power

M3 OR M4 = SET M140

M2 OR M5 OR M30 OR RESETOUT OR NOT O1= RES M140

;Request for Spindle rotation

;Cancel spindle rotation

M19 = SET M119 ;Request for M19

M2 OR M3 OR M4 OR M5 OR M30 OR RESETOUT OR NOT O1 = RES M119 ;Cancel M19

(M140 OR (M119 AND NOT LOPEN)) AND M113 = SPENAS = TG3 3 4000

T3 = DRENAS ;4 sec. delayed deactivation

; for emergency stops.

SPENAS AND (M119 OR RIGID) AND NOT LOPEN = SERVOSON ;M19 or Rigid Tapping, close the loop.

;----- MANAGING FEED HOLD AND STOP -----

M133 AND (others) = /FEEDHOL

Applications Ver. 0002 AP - 13

AP.2

CONNECTION WITH THE FAGOR 8070 CNC

The Fagor 8070 CNC has some general configuration parameters similar to those of the

Fagor drive. These parameters must be set so they are consistent with the ones set at the drive.

The are:

OPMODEP Similar to parameter AP1 -S32- PrimaryOperationMode.

Give this parameter a value consistent with that of AP1 at the drive.

LOOPTIME Similar to parameter QP1 -S1- ControlUnitCycleTime of the drive.

Same.

Other parameters must also be set for each axis.

They are:

DRIVETYPE Indicates the type of interface being used.

To connect the 8070 CNC with Fagor drives, DRIVETYPE = Sercos

TELEGRAMTYPE Telegram type used in Sercos communication.

Set TELEGRAMTYPE = 4.

DRIVEID Identifies the drive in the Sercos ring.

Set this parameter with the same value as the one selected at the drive's thumbwheel.

NPULSES

PITCH Parameters that determine feedback resolution.

The 8070 can work with a resolution of a tenth of a micron.

Thus, the relationship between these two parameters must be:

PITCH

NPULSES · 4

= 0.1

µ

AP - 14 Applications Ver. 0002

AP.3

PARAMETER SET AND GEAR RATIOS

The Fagor Servo Drive System is configured by means of a parameter table.

Some of these parameters are arrays of eight elements, ordered with endings going from zero up.

One of these arrays is, for example: SP1.0, SP1.1, SP1.2, ...... SP1.6 and SP1.7.

The parameters extended into "arrays" are organized in two groups called "Parameter set" and "Gear Ratios". The illustration shows the organization of the table.

Terminology:

Parameter Set refers to the set of parameters of the Drive which determine the setup of the drive and are grouped by the same ending.

For example, the Parameter set Zero consists of CP20.0, IP1.0, SP1.0 ··· SP10.0,

SP20.0, SP21.0, SP40.0, SP41.0, SP60.0 ··· SP65.0, SP80.0 and SP100.0.

Each parameter set may configure the same drive differently. This choice may be made by just changing the Active Set.

The parameter setup for a "C" axis MUST BE made using the Parameter Set Seven.

Gear refers to the purely mechanical ratio regardless of how the parameters have been set.

Gear 0 refers to "out of gear". No transmission (in neutral).

Gear 1 is the lowest gear with the greatest speed reduction.

Gear 2 and the rest will be higher gears.

Gear Ratio refers to the set of Drive parameters grouped by the same ending and that informs the Drive of the motor-machine transmission (gear) ratio.

For example, Gear Ratio 2 consists of NP121.2, NP122.2 and NP123.2. The choice can be made by just changing the Active Ratio.

They are numbered from Gear Ration 0 to 7.

The gear ratio parameters inform of the gear in operation according to:

Gear Ratio 0 Gear 1

Gear Ratio1

Gear Ratio2

Gear 2

Gear 3 etc...

Applications Ver. 0002 AP - 15

Any parameter may be edited at any time (eight sets and eight gear ratios). The Backup and

Restore operations affect the whole parameter table.

Each time, only one of those "sets" and one of those "gear ratios" determine the operation of the system . They are the Set and Gear ratio active at the time.

All Set-GearRatio combinations are possible.

Important parameters:

GP4, number of useful sets

GV21, active set

The drawing shows an example:

GP6, number of useful gear ratios

GV25, Active gear ratio.

Parameters GP4 and GP6 limit the number of sets and gear ratios that can be activated.

For example, with GP4=4 the values of Active Set are limited to between 0 and 3.

Important:

Assigning a motor ID to the GV10 variable resets the whole parameter table to their default values. Particularly, GP4=1 and GP6=1 thus leaving Set 0 and Gear Ratio 0 as the only ones that can activated.

Turning the drive back up sets GV21=0 and GV25=0.

The next sections describe the operation of these two subsets.

Parameter Table

Example:

GP4=8 GV21=3

GP6=6 GV25=1

General parameters

AP1 BV1 ......

..........................

Se t 3

CP

Ac tua lSe t

IP

1.

3

20

CP20.0

.3

SP

20.

SP

0

60.

SP1

.3

SP

10

.3

...

....

SP

41

.3

SP

100.

3

Set 7

Set 6

SP

21

.3

SP

65

.3

...

....

SP

40.

3

SP

80

.3

Set 5

Set 4 SP10.7

SP10.6

Set 2

Set 1

Set 0

SP10.5

SP10.4

SP100.7

SP100.6

SP10.1

SP1.0 ....... SP10.0

SP10.2

SP100.5

SP100.4

SP20.0

SP60.0

SP21.0

.......

SP65.0

SP40.0

SP80.0

SP41.0

SP100.2

SP100.1

SP100.0

&

Ac tua lGe arR ati o

NP

Ge

121.

1

NP

122.

NP121.5

123.

ar R

5 ati o 1

1

NP121.5

Gear Ratio 4

NP121.5

Gear Ratio 5

NP122.5

NP121.5

NP123.5

NP123.5

NP122.4

NP123.5

NP122.0

NP122.3

NP123.0

&

......

.........................

XV1 XV2

General parameters

AP - 16 Applications Ver. 0002

AP.3.1

PARAMETER SET

The Active Set may be changed by means of external digital signals or through the Sercos interface.

AP.3.1.1

SET CHANGE THROUGH DIGITAL INPUTS

Running status:

Parameter GP4 sets the number of useful sets (1 < GP4 < 8).

Variable GV21 informs of which is the currently active set.

(0 < GV21 < GP4).

Boolean variables to change the active set:

GV32, GV31 and GV30 are used to preselect the new active set.

GV22 registers this preset.

GV24 "Strobe" lets or not change the active set.

GV23 "Acknowledge" is the acknowledgment of the set change.

The default value of all three preselection variables is zero.

The default value of the Strobe signal is "1" (active).

SetActiveBits

Set 0

Set 1

Set 2

Set 3

Set 4

Set 5

Set 6

Set 7

0 0 0

0 0 1

0 1 0

0 1 1

1 0 0

1 0 1

1 1 0

1 1 1

MUX

SetChangeStb

GV24

GV22

&

ParameterSetPreselection

ActualParameterSet

Delay GV21

Set change procedure:

Assign to inputs IP10-13 the boolean variables to be governed.

Use these digital inputs to preselect the new set that will be active.

Activate the "Strobe" signal by means of the electrical signal assigned to GV24.

The "Strobe" signal GV24 may be deactivated with a delay or as a result of an up flank (leading edge) of the "Acknowledge" GV23.

The diagram of the following page is an example:

Applications Ver. 0002 AP - 17

20 ms

GP4=4

IP12=GV31

IP13=GV30

IP10=GV24 pin3-5 X6

24 V

0 V pin4-5 X6

24 V

0 V pin1-5 X6

24 V

0 V

GV23 SetChangeAck

1

0

GV21 ActualParameterSet

Strobe

Acknowledge

0 2 3

1

0

1

0

1

0 t t t t t

Operation with the Strobe always active:

GV24 "Strobe" will stay active if it is not assigned to a digital input.

This way the change of sets is handled directly without control signals, with GV32-30.

in order to avoid possible disturbances or rebounds on those electrical signals, they should maintain their new values for at least 20 milliseconds.

The drawing below is an example.

GP4=4

GV24=1 unassigned

IP12=GV31

IP13=GV30 pin3-5 X6

24 V

0 V pin4-5 X6

24 V

0 V

GV23 SetChangeAck

1

0

GV21 ActualParameterSet

20 ms

Acknowledge

0

< 20 ms

>100 ms

1

20 ms

3

1

0

1

0 t t t t

Remarks:

The active set may be changed while the motor is running. If the motor is turning faster than the limit established by the new parameter set, the speed will decrease automatically until the value of such limit is reached and only then, the new parameter set will become effective. The ramp used to make this change of speed will be the one determined by the previous set.

AP - 18 Applications Ver. 0002

"Acknowledge" signal for a set change set.

This signal is used as confirmation of the change. It will go to "0" with the up flank of the

"Strobe" signal and it will go back to "1" when the change is completed.

Even when the new set is the same as the old one, this acknowledge signal GV21 will be set to "0" for 100 milliseconds.

See the diagram below.

GP4=8

IP11=GV32

IP12=GV31

IP13=GV30

GV32-GV30

IP10=GV24 pin1-5 X6

24 V

0 V

GV23 SetChangeAck

1

0

GV21 ActualParameterSet

5

Strobe

Acknowledge

0 5

5

100 ms

5

1

0

1

0 t t t t

AP.3.1.2

SET CHANGE THROUGH SERCOS INTERFACE

The procedure is identical and parallel to the change of gear ratio.

See the section on "Change of gear ratio through Sercos interface".

There is a very important aspect to be considered when changing Sets through Sercos

Interface:

To change a parameter set through Sercos interface, the variables GV24, GV30,

GV31 and GV32 MUST NOT be assigned to a digital input.

Applications Ver. 0002 AP - 19

AP.3.2

GEAR RATIOS

The gear ratios consist of parameters NP121, NP122 and NP123 only.

These parameters indicate the mechanical transmission ratio between the motor and the axis ballscrew or between the motor and the tool in the spindle. NP123 indicates the pitch of the ballscrew.

Axes:

These parameters must be set for each Gear Ration and change the Active Ratio with each gear change.

Spindle:

These NP parameters must be updated for each change of Gear only when working in

SERCOSLE=1 mode and if we want to display the spindle speed on the CNC screen or work in M19 mode or in Rigid Tapping.

In those cases, the mechanical maneuver in the machine gear box will be accompanied by a change of Active Gear Ratio

The command to change gears is given through the Sercos interface. This change cannot be handled through digital inputs.

Operation status:

Parameter GP6 sets the number of useful gear ratios (1 < GP6 < 8).

Variable GV25 informs which is the current (actual) gear ratio (0 < GV25 < GP6).

Variable GV26 registers the preselected Gear Ratio

GearRatioPreselection

GV26 Delay

ActualGearR atio

GV25

AP - 20 Applications Ver. 0002

AP.3.2.1

CHANGE OF GEAR RATIO THROUGH SERCOS INTERFACE

Change procedure via Sercos also applicable to the change of Sets.

The CNC changes gear ratios by means of commands M41, M42, M43 and M44. By setting parameter AUTOGEAR (P006) to "YES", the CNC will automatically generate the previous M codes according to the selected speed. If AUTOGEAR="NO", the user must include these M codes into the part-program.

Procedure:

First, determine the number of useful sets and gears by writing into these variables:

GP4

GP6

33471 (F00703) SetNumber

33485 (F00717) GearRatioNumber

Write into the CNC variables which the new set and new gear ratio will be:

SETGEX, SETGEY, SETGEZ, etc ..............

SETGES .................................................

SSETGS ................................................

for the axes for the main spindle for the second spindle.

The four least significant bits of these variables register the active gear and the other four the active set as shown in the diagram below:

Bit

7 6 5 4

0 0 0 0

0 0 0 1

0 0 1 0 etc..

Set 0

Set 1

Set 2

GV21=0

GV21=1

GV21=2

Bit

3 2 1 0

0 0 0 0

0 0 0 1

0 0 1 0 etc..

Gear Ratio 0

Gear Ratio 1

Gear Ratio 2

Range 1

Range 2

Range 3

GV25=0

GV25=1

GV25=2

These writings are done through the Service Channel (slow). This channel is accessed via part-program instructions, from the PLC channel or from the user channel.

A new PLC mark (SERPLCAC -Sercos PLC Acknowledge-) serves as a confirmation of the change. It will stay active from when a new set or gear ratio is requested with the previous variables (SETGEX,etc..) until the Drive assumes the new values for its GV21 parameters:

ActualParameterSet and GV25 ActualGearRatio.

While these mark is active, no other SETGE* change can be requested because the command would be lost.

Applications Ver. 0002 AP - 21

AP.3.2.2

EXAMPLE OF A PLC PROGRAM FOR A GEAR CHANGE AT THE

MAIN SPINDLE

Example of a spindle with SERCOS interface on the next page.

The spindle has two ranges and works in open loop.

It does not use external feedback, but that of the motor itself, that is: SERCOSLE=1.

Therefore, to display the real "S" at the CNC, one must change the gear ratio at the drive with each range change at the machine.

The drive of the main spindle is identified with the number 3 of the SERCOS ring.

(SERCOSID = 3 in the parameter table of the main spindle S).

Therefore, one must set the PLC parameter P28(SRR700) = 3.33172.

("33172" is the SERCOS identifier of the variable DV11 (F-404)).

This makes register R700 (associated with parameter P28) contain the variable

DV11 "FagorDiagnostics" of the main spindle through which we know the

"ActualGearRatio" (GV25).

At the CNC, the spindle table must be defined.

Spindle in open loop with three ranges.

The feedback is defined with SERCOSLE=1

SERCOSID = 3

At the drive.

Two gear ratios an a single parameter set must be defined:

Gear Ratio 0 Gear 1

Gear Ratio 1 Gear 2

Parameter set 0.

GP4 = 1

GP6 = 2

AP - 22 Applications Ver. 0002

;

; -- EXAMPLE OF A PLC PROGRAM FOR A GEAR CHANGE AT THE MAIN SPINDLE --

;

; Information on resources in use:

; I41 = Detector for first gear (M41)

; I42 = Detector for second gear (M42)

; I79 = “Drive OK” Spindle Drive

;

; O141 = Electric valve to activate the first gear (M41)

;

; O142 = Electric valve to activate the second gear (M42)

; M41 = Decoding of "M41" from CNC: Change to first gear

;

; M42 = Decoding of "M42" from CNC: Change to second gear

; With parameter PLC P28 (R700) = 3.33172, we define the SERCOS identifier Fagor Diagnostics,

; because in this case, at the spindle, SERCOSID = 3

; B10R700 = SV3. This bit is activated when the spindle speed is lower than the minimum "N" (SP40).

;

;

CY1

;

END

;

PRG

REA

;

;---------- DRIVE STATUS ---------

;

DRSTAFS = B1R104

DRSTASS = B0R104

;

CPS R104 GE 1 = M104

M104

AND I79

;

= M200

CPS R104 GE 2 = M114

;

I1 AND M200 = /EMERGEN

;

/EMERGEN AND /ALARM = O1

;---------- GEAR CHANGE ---------

;

M2047 = AND R700 $0F R45

;

B9R700 = TG2 30 200

B10R700 = TG2 31 200

T30 = M155

T31 = M156

; Reading of the spindle drive running status.

; Spindle drive OK

;Drive OK (by software)

;Drive OK (by hardware)

;Drive OK.

; Spindle drive under power

; Emergency to the CNC

;Emergency contact to the electrical cabinet

;Read variable GV25 «ActualGearRatio»

; Confirmation delay N=0

; Confirmation delay N=Nmin

; N=0

; N=Nmin

I41 AND NOT I42 = TG2 41 200

I42 AND NOT I41 = TG2 42 200

;

T41 = GEAR1

;

T42 = GEAR2

M114 AND M41

AND NOT GEAR1

= SET M141

;

M114 AND M42

AND NOT GEAR2

;

= SET M142

M141 OR M142 = M150

= TG2 10 5000

;Confirmation delay for 1st gear

;Confirmation delay for 2nd gear

;Confirmation of 1st gear at the machine

;Confirmation of 2nd gear at the machine

;Request for change into first gear

;Request for change into second gear

;Spindle gear change in progress

Applications Ver. 0002 AP - 23

;

T10 = SET MSG10

;

RESETOUT OR NOT O1= RES MSG10

;

M150 AND M156 = MOV 100 SANALOG = PLCCNTL

PLCCNTL AND M2011 = SPDLEREV

;

;

M141 AND NOT SERPLCAC

= SET M241

NOT M242 AND GEAR1

AND NOT CPS R45 EQ $00

AND NOT SERPLCAC

;

= SET M341

M241 OR M341 = M146

DFU M146 = MOV $00 R41

= CNCWR(R41,SETGES,M1000)

;

M146 AND CPS R45 EQ $00

AND NOT SERPLCAC AND GEAR1

= RES M141 = RES M241

= RES M341

;

M142 AND NOT SERPLCAC

= SET M242

;

NOT M241 AND GEAR2

AND NOT CPS R45 EQ $01

AND NOT SERPLC

= SET M342

M242 OR M342 = M147

DFU M147= MOV $01 R41

;

= CNCWR(R41,SETGES,M1000)

M242 AND CPS R45 EQ $01

AND NOT SERPLCAC AND GEAR2

= RES M142 = RES M242

;

= RES M342

T10 OR NOT O1 OR RESETOUT

= RES M141= RES M142 = RES M241

= RES M242= RES M341 = RES M342

;

M241 AND O1 AND M156 = O141

M242 AND O1 AND M156 = O142

;

;---------- ENABLING THE DRIVE ---------

;

M3 OR M4 = SET M140

M2 OR M5 OR M30

;

OR NOT O1 OR RESETOUT = RES M140

(M140 OR PLCCNTL )

AND M114

AND (Closed door conditions)

= SPENAS = TG3 3 4000

T3 = DRENAS

;Gear change time exceeded

;Gear change oscillation (100*0,3=30 mV.)

;Reversal during gear change

;Request and free service channel

;Latching the request for drive's first gear ratio

;1st gear does not match drive's gear ratio

;Latching the request for drive's first gear ratio

;Request for drive's first gear ratio

;Confirmation of the change into first gear

;Request and free service channel

;Latching the request for drive's second gear ratio

;2nd gear does not match drive's gear ratio

;Request for drive's second gear ratio

;Confirmation of the change into second gear

;Cancel request for a gear change

;Activate servo valve to change into first gear,

;Activate servo valve to change into second gear,

; Request for spindle rotation.

; Cancelation of spindle rotation.

; Drives under power

; Closed door

; Enabling the spindle analog

; Enabling the spindle drive

AP - 24 Applications Ver. 0002

;

;---------- AUXEND, /XFERINH, /FEEDHOLD ---------

DFU STROBE OR DFU TSTROBE

OR DFU T2STROBE OR DFU MSTROBE

;

= TG1 1 100

NOT T1

AND NOT M150

= AUXEND

;

NOT M241 AND NOT M242

= /XFERINH

;

= /FEEDHOLD

END

; confirmation pulse STROBES

; Gear change in progress at the drive

; M,S,T functions being executed

; Gear change in progress at the drive

; Locked CNC block reading

; Feedhold for CNC axes

AP.3.2.3

EXAMPLE OF A PLC PROGRAM FOR A PARAMETER SET

CHANGE

This example shows how to work with in both spindle and "C" axis mode with the same drive.

The drive of the main spindle (S) is identified as number 3 in the Sercos ring.

At the drive.

A different parameter set must be defined (it must be the last set -7- for the "C" axis ). In the "C" axis mode, the machine must be forced to work in the lowest range (greater gear ratio) and indicate it to the Drive (Gear Ratio 0).

Set: GP4 = 8 (to make it possible to activate set 7)

GP6 = 1 (to only work with Gear Ratio 0, in this example).

Two tables must be defined at the CNC:

Spindle table.

"C" axis table.

SERCOSID = 3

Spindle in closed loop working as a regular axis.

Set the external feedback (SERCOSLE=0) with all the necessary parameters. SERCOSID = 3

Important:

When using the same motor as "C" axis or as a spindle, both CNC tables must have the same SERCOSID parameter value.

Set PLC parameter P28(SRR700) = 3.33172.

(The number 33172 is the SERCOS identifier of variable DV11 (F-404))

This way, register R700 (associated with parameter P28) will contain the DV11 -F00404variable "FagorDiagnostics" of the main spindle making it possible to know variables

"ActualParameterSet" (GV21) and "ActualGearRatio" (GV25) through it.

Applications Ver. 0002 AP - 25

;-- EXAMPLE OF A PLC PROGRAM FOR A SET CHANGE AT THE MAIN SPINDLE (C AXIS) ---

;

;

; Information of the resources being used:

;

; I79 = “Drive OK” spindle drive ("C")

;

; PLC parameter P28 (R700) = 3.33172, set SERCOS identifier Fagor Diagnostics,

; because, in this case, at the spindle, SERCOSID = 3

;

CY1

;

;

END

PRG

REA

;

;---------- DRIVE STATUS --------

DRSTAFS = B1R104

DRSTASS = B0R104

DRSTAF3 = B1R105

; Spindle drive status

;

DRSTAS3 = B0R105 ; "C" axis drive status

;

; The DRSTAFS and DRSTASS signals behave like the DRSTAF3 and DRSTAS3 signals

CPS R104 GE 1 = M104 ; Spindle OK

; "C" axis OK

;

CPS R105 GE 1 = M105

M104 AND M105

AND I79

= M200

; Drive OK (by software)

; Drive OK (by hardware)

; Drives OK.

;

CPS R104 GE 2 = M114

;

CPS R105 GE 2 = M115

I1 AND M200 = /EMERGEN

;

/EMERGEN AND /ALARM = O1

;

;---------- "C" AXIS ----------

M2047 = AND R700 $FF R45

; Spindle drive under power

; "C" axis drive under power

; Emergency to the CNC

; Emergency contact to the electrical cabinet

; Mask to get GV21 and GV25

; GV21: Active parameter table

; GV25: Active gear ratio

;

;

DFU CAXIS = SET M251

M115 AND M251 AND NOT M262

AND NOT SERPLCAC

;

= SET M252

DFU M252 = MOV $77 R41

; "C" axis request

; Free user channel

; Write permission for parameter table at the drive

; Selects parameter table 7 at the drive

;

;

= CNCWR(R41,SETGES,M1000)

CPS R45 GE $77 AND NOT CAXIS

= SET M261

M115 AND M261 AND NOT M252

AND NOT SERPLCAC

;

= SET M262

DFU M262

;

= MOV $00 R41

= CNCWR(R41,SETGES,M1000)

; End of "C" axis mode.

; Write permission for parameter table at the drive

; Selects parameter table 0 at the drive

AP - 26 Applications Ver. 0002

M252 AND CPS R45 EQ $77

AND NOT SERPLCAC

= RES M251

= RES M252

;

M262 AND CPS R45 EQ $00

AND NOT SERPLCAC

= RES M261

= RES M262

;

CAXIS AND NOT M251 = SET CAXSEROK

NOT CAXIS AND NOT M261 = RES CAXSEROK

;

;---------- ENABLING THE DRIVE ----------

;

CAXSEROK

AND M115

AND (Closed door conditions)

AND NOT LOPEN

= TG3 58 4000

= SPENA3

= SERVO3ON

;

T58 = DRENA3

;

M3 OR M4 = SET M140

M2 OR M5 OR M30

;

OR NOT O1 OR RESETOUT = RES M140

((M140 OR PLCCNTL )

OR (CAXIS AND NOT CAXSEROK))

AND M114

AND (Closed door conditions)

= SPENAS = TG3 3 4000

;

T3 = DRENAS

;---------- AUXEND, /XFERINH, /FEEDHOLD --------

;

;

DFU STROBE OR DFU TSTROBE

OR DFU T2STROBE OR DFU MSTROBE

= TG1 1 100

NOT T1 AND

NOT SERPLCAC

;

= AUXEND

NOT SERPLCAC

= /XFERINH

= /FEEDHOLD

;

END

;Selected C axis parameter table

; Spindle parameter table selected

; "C" axis confirmation to the CNC via sercos Ready

; Active "C" axis

; Drives under power

; Closed door

; Speed enable of the "C" axis

; Enabling the "C" axis

; "C" axis "Drive enable"

; Request for spindle rotation.

; Cancelation of spindle rotation.

; Drives under power

; Closed door

; Enabling the spindle analog

; Enabling the spindle drive

; STROBES confirmation

; Parameter set change in progress

; M,S,T functions being executed

; Parameter set change in progress

; CNC block reading locked

; Feedhold for CNC axes

Applications Ver. 0002 AP - 27

AP.3.3

SETS AND GEAR RATIOS AT THE DDSSETUP MONITOR

This section describes how the monitoring program handles the sets and gear ratios.

Listing of values and meanings of the parameters of a set:

Driver > S 3 <return> lists the values of the parameters of set number three.

Edit / modify a parameter of a single set.

Driver > SP1.3 100<return> it will assign a value of 100 to SP1 of set number three.

Edit / modify a particular parameter in all the sets:

Driver > SP2.* 300<return> it will assign the value of 300 to the SP2 of all eight sets.

Any modification made onto a parameter without indicating a particular set will affect the parameter corresponding to set zero.

Note: the numerical data of these parameters and variables are given in the units used by the DOS-based

"ddssetup.exe". The Winddssetup (for Windows) may use different units which will be displayed on the screen.

AP - 28 Applications Ver. 0002

AP.4

VARIABLE MONITORING

The continuous monitoring of internal variables of the Drive module may be carried out in two ways: By electrical signals through the digital and analog outputs or by showing their values on the display of the Programming Module.

For example, to monitor the power of the asynchronous motors (TV50) and the motor torque on the synchronous ones (TV2) through the analog outputs and to see if the motor is stopped

(SV5) through a digital output:

OP1=TV50 Power variable through channel 1, pins 10/11 of X7.

OP3=10000 Ten Kilowatts per volt

OP2=TV2

OP4=1000

OP10=SV5

Torque variable through channel 2, pins 8/9 of X7

A thousand deciNm per 10 volts (10 Nm / volt)

Closed contact between pins 6/7 of X6 is the motor is stopped.

AP.4.1

PROGRAMMING MODULE AS MONITOR

Internal Drive variables may be monitored permanently on the screen of the Programming

Module.

Select the digital or analog variable from the VARIABLES menu.

Bear in mind that their units are the ones appearing in the Appendix A and when the cursor is located under the value of a variable, the monitoring is temporarily frozen.

The bottom line shows the name of the variable. Its full name can be displayed by pressing the O key. Example:

Applications Ver. 0002 AP - 29

AP.4.2

DIGITAL ELECTRICAL SIGNALS FOR PLC OR MANOEUVER

Four internal boolean variables of the Drive can be taken to the digital outputs offered by connector X6 of the A1 card. These digital outputs may participate in the maneuver of the electrical cabinet.

The variables chosen most often are:

Speed lower than Nx SV3 = nFeedbackMinorNx (See SP40)

Command speed reached SV4 = nFeedbackEqualNCommand (See SP41)

Motor stopped

Torque smaller than Tx

SV5 = nFeedbackEqual0

TV10 = TGreaterTx

(See SP42)

(See TP1)

Example:

OP12=TV10 The contact between pins 10/11 will be closed if the motor torque exceeds the threshold value Tx set by parameter TP1.

The contact between pins 6/7 will be closed if the motor is stopped.

OP10=SV5

Check the EM chapter of this manual in order not to exceed the electrical limitations for these electrical contacts.

(A1 Board)

1

(Phoenix,

3.5 mm)

1

13

1

A1

Pin

8

9

10

11

12

13

3

4

5

6

7

1

2

IN 1

IN 2

IN 3

IN 4

REF-IN

(IP10 -F00901-)

(IP11 -F00902-)

(IP12 -F00903-)

(IP13 -F00904-)

OUT 1 (OP10 -F01404-)

OUT 2 (OP11 -F01405-)

OUT 3 (OP12 -F01406-)

OUT 4 (OP13 -F01407-)

AP - 30 Applications Ver. 0002

AP.4.3

ANALOG OUTPUTS FOR THE "DIAL"

Two internal variables of the Drive can be represented permanently on the machine's operator panel by means of volt-meters.

The most often monitored variables are:

On spindle drives:

On axis drives: on both:

Power in use, TV50.

Motor torque, TV2.

TV3, portion of available power being developed by the motor.

This variable is given in a 0

/

00 and is valid for synchronous and asynchronous motors in any duty cycle.

1st example:

Let us suppose that we have a volt-meter with a measuring range of +5Vdc corresponding to a range from 0% to 100%. We wish to use it to represent the percentage of power being used with respect to the one available. The setting must be as follows:

OP2=TV3 Percentage of power used with respect to the maximum power available, channel 2, pins 8/9 of connector X7.

OP4=2000 2000 o

/ oo

/ 10volts = 1000 o

/ oo

/ 5volts (TV3 in o

/ oo

)

2nd example:

We installed a volt-meter with a measuring range of +12Vdc corresponding to a range between 0% and 200%. We wish to use it to represent the percentage of rated power (S1) being developed. The spindle motor has a rated power S1 = 11 kW.

The setting must be as follows:

OP1=TV50 Power feedback, channel 1, pins 10/11 of connector X7.

OP3=1833 1833 DecaWatts / 10volts (TV50 comes in DecaWatts) according to:

11kW 2

10

12

=

18.33kW

=

1833DecaWatts

Even if the needle never reaches the top of the scale because the maximum output voltage will be 10V. At its maximum power in S6 (16kW) the dial will show 8.72 V.

Warning:

If the values assigned to OP3 and OP4 are too small the electrical signal will saturate when reaching 10 Volts.

1st example.

Power Percentage

0

0%

1

2

50%

3

+5 Volt

Voltmeter

4

5 volts

100%

2.5V

5V

50%

100%

2nd example.

Power S1 Percentage

2

0

0%

4

6

100%

8

10

12 volts

200%

+12 Volt

Voltmeter

6V

8.72V

10V

100%

145%

166%

11kW

16kW

18.3kW

Applications Ver. 0002 AP - 31

AP.5

HANDLING OF INTERNAL VARIABLES VIA SERCOS

The features documented in this chapter need the following software versions:

8050/55 CNC versions V13.02 (mill) and V12.01 (lathe).

Drive versions V03.01 and later.

The data transmitted through the Sercos ring is classified in two groups:

Cyclic channel (fast):

It is updated at every position loop. It contains the velocity commands, feedback, etc.

Each variable read or written at the Drive is included in this information package. In order not to overload the interface, one must limit the number of affected variables of the drive to a minimum.

Service channel (slow):

Data transmitted at every certain number of position loops (monitoring, etc.)

This channel is accessed through part-program instructions, from the PLC channel or from the user channel.

Cyclic channel. Variables of the Drive to be read from the PLC.

These variables are:

(See appendix A of this manual):

Driver name Sercos ID Name

------------------------------------------------------------------------------------

DV9 00012 -S12Class2Diagnostics(Warnings)

DV10

SV2

PV51

00013

00040

00051

-S13-

-S40-

-S51-

Class3Diagnostics(OperationStatus)

VelocityFeedback

PositionFeedback1

------------------------------------------------------------------------------------

TV2 00084 -S84TorqueFeedback

CV3

DV11

IV1

33079

33172

33673

-F311-

-F404-

-F905-

CurrentFeedback

FagorDiagnostics

AnalogInput1

------------------------------------------------------------------------------------

IV2 33674 -F906AnalogInput2

IV10

TV50

TV3

33675

34468

34469

-F907-

-F1700-

-F1701-

DigitalInputs

PowerFeedback

TorqueFeedbackPercentage

Identify the drive parameter to be read in one of the parameters P28-P67 of the PLC table. Use an "n.i" format where "n" is the drive identifier in the Sercos ring and "i" is the

Sercos identifier of the drive parameter. See the next example.

These PLC parameters P28-P67 are associated with registers:

P28 with R700 P29 with R701 P30 with R702

Reading example: Set P28=4.33172 in the CNC machine parameters.

etc...

This way, PLC register R700 will contain the value of the variable DV11 -F00404which belongs to the drive identified with the Sercos number 4.

AP - 32 Applications Ver. 0002

Cyclic channel. Drive variables to be written from the PLC.

Use PLC machine parameters P68-P87 associated with registers:

P68 with R800 P69 with R801 P70 with R802

The Drive variables which can be written from the PLC are:

(see appendix A of this manual): etc...

Driver name Sercos ID Name

------------------------------------------------------------------------------------

OV1

OV2

OV10

34176

34177

34178

-F1408-

-F1409-

-F1410-

DA1Value

DA2Value

DigitalOutputs

SV1 00036 -S36VelocityCommand

(This variable SV1 can only be written for axes set as DRO axes)

Reading example: Set P69=1.34176 in CNC machine parameters.

This way, the value of OV1 of the drive identified as Sercos number 1 may be assigned to PLC register R801.

If we now write ... = MOV 8000 R801 the analog output of channel 1 (pins 11/10 of connector X7) will output 2441 mV.

Voltage = Register · 0.3 Volts

Service channel. Drive variables to be read or written.

This Service Channel can only be accessed through a high-level block of the partprogram, PLC channel or user channel. Use CNC machine parameters P100-P299.

All "non-string" type variables can be accessed (see appendix A of this manual).

From the part-program or user channel:

Reading example: (P100=SVARX 40)

Parameter P100 will be assigned the value of the X axis motor speed. That is:

VelocityFeedback (00040).

If, for example, the speed were 200 rpm, P100 would assume a value of

200000.

Writing example: (SVARZ 36=P110)

It will assign the value of parameter P110 to the Z axis velocity command,

VelocityCommand (00036)

If P110 were 3500000, the velocity command would be forced to 350 rpm.

Parameter = Velocity (rpm) · 10000

From the PLC channel:

Reading example: ...=CNCEX((P100=SVARX 40),M1)

Writing example: ...=CNCEX((SVARZ 36=P110),M1)

Applications Ver. 0002 AP - 33

AP.6

SPINDLE MOTORS AT LOW RPM

In some cases, it would interesting to avoid the gear box on the machine spindle. That requires a drive offering constant power at low speed.

This motor behavior may be achieved by limiting its power.

The next example shows how to do it:

A motor is to be installed on a machine offering 5 kW in S1 for speeds over 500 rpm.

Solution:

The SPM132L motor offers a rated power of 15 kW in S1 and 22 kW in S6-40%. Its base speed (from which it really offers that power) is 1500 rpm.

By limiting its maximum power to a third of its capability, the effective base speed will be reduced to one third, that is 500 rpm.

This effect is controlled by means of parameter MP22 (Fagor access level).

Important:

The power limitation at the motor does not imply the possibility of controlling it by a smaller drive.

However, the power demanded to the Power Supply will be smaller.

AP - 34 r (kw) powe r (kw) powe

Applications Ver. 0002

AP.7

HALT FUNCTION

Activating the HALT function means setting the velocity command to zero while keeping the rotor locked (with torque). As opposed to the effect of deactivating the Speed_Enable function, the Halt function does not free the motor when it has stopped it.

It can be activated through an electrical signal at one of the digital inputs of the drive, by the monitoring program through the serial line or through the Sercos interface.

The Halt function is activated (stops the motor) when: when applying zero volts at the electrical input assigned to variable BV1 -F00201-, or when requested from the monitoring program (variable BV3 -F00202-= 0), or when requested from the PLC of the CNC via Sercos (bit 13 of DV32 -S00134- is set to

"0").

H a ltD riv e P in

H a ltD riv e D n c

H a lt (S e rc o s )

B V 1 -F 2 0 1 -

B V 3 -F 2 0 2 -

D V 3 2 -S 1 3 4 -

(b it 1 3 )

O R

H a lt F u n c tio n

By programming drive variable BV1, one of the four digital inputs of connector X6 can perform the Halt function. To make the motor stop more smoothly, its deceleration can be limited with parameter SP65 (SP70=1, SP100=1).

This is a programming example with a graph showing its operation:

IP10 -F00901- = BV1 -F00201-

SP70 -F01610- = 1

SP100 -F01611- = 1

SP65 -F01609- = 500 rad/sec 2

This way, when pin 1 (referred to pin 5) of connector X6 receives zero volts, BV1 -F00201- will assume the zero value and the Halt function will be activated. The motor will stop with a maximum deceleration of 500 rd/s 2 and will stay locked. With 24 V at that pin, the servo drive will continue to follow the velocity command.

Digital

Input

V

1-5 X6

24 V

0 V time

AnalogInput1 IV1 -F905time

VelocityCommand

BeforeFilters

SV8 -F1613-

Velocity

Command

Final

SV7 -F1612-

SP65 -F1609with SP70 -F1610- = 1

& SP100 -F1611- = 1

Note: the numerical data of these parameters and variables are given in the units used by the DOS-based

"ddssetup.exe". The Winddssetup (for Windows) may use different units which will be displayed on the screen.

time time

Applications Ver. 0002 AP - 35

AP.8

MOTOR STOP DUE TO TORQUE OVERLOAD

From software version 02.04 on, includes a new feature especially designed for spindle drives although it is also available for axes.

It offers the possibility to detect that the motor has stopped when, for instance, the tool gets stuck.

This detection triggers an Error message and it is handled by means of two new parameters.

Operation:

When the Drive detects that the motor speed is below the threshold set by GP8 -F236and the internal current command is near its maximum value (CP20 -F307-), an internal timer starts running.

If the time elapsed under these conditions (torque overload condition) exceeds the time value set by GP7 -F235-, error 203 is issued.

If the internal torque command drops below its maximum value or the motor speed is resumed, the internal timer is reset back to zero.

Parameters:

GP7 O

Function:

Valid values:

Default value:

Version:

GP8

Function:

O

Valid values:

Default value:

Version:

(F235) OverloadTimeLimit

When the overload conditions exceed this time period, the error is issued.

0..10000 milliseconds. With GP7 =0 this protection is disabled.

200

Available from version 02.04 on.

(F236) OverloadVelocityThreshold

Sets the speed threshold under which the motor is considered to be stopped in terms of overload detection.

0..1000 rpm

100 (Asynchronous Motors), Rated Speed (Synchronous Motors).

Available from version 02.04 on.

Generated Error message:

203 Torque overload error.

- The servo drive is locked up and it can not turn freely. Due to too high a torque, the turning speed has not exceeded the GP8 value for a time period greater than the GP7 -F235- value.

Free the motor. If the error comes up for no apparent reason, increase the GP7 -F235- and/or GP8 -F236values. If GP7 is set to “0”, the error message is never issued.

AP - 36 Applications Ver. 0002

AP.9

FLUX REDUCTION WITHOUT LOAD

Software version 04.01 includes a new feature for spindle motors.

While the motor is turning without a load, this feature makes it possible to momentarily decrease the magnetizing current. This considerably decreases the noise generated by the motor and its heating.

This reduction does not affect the power output, since the magnetizing current increases automatically when motor torque is needed.

The parameter used for this is:

FP40.# -F613.#FluxReduction

Since the settling of the flux and maximum motor torque has a delay, it is not recommended to use this flux reduction on motors used to feed the axes.

This parameter is expanded in eight sets of values for adapting it with each gear change.

Applications Ver. 0002 AP - 37

User notes:

AP - 38 Applications Ver. 0002

DS. DESIGN

DS.1 AXIS MOTOR AND SERVO DRIVE SELECTION

DS.1.1 FIRST MOTOR PRE-SELECTION

The motor must meet the specifications on Torque (Nm), speed, duty cycles or other kind of requirements of the axis to be moved. An axis may be like this:

Calculation of the necessary Motor Torque (M)

The total motor torque necessary has two components, the Continuous Torque M

S

(to maintain the table at a constant speed or fixed in a position), and the Acceleration Torque M

A

(to change its speed).

The reduction in the Motor ballscrew transmission ( i) is a factor to be considered in many of the following calculations.

M

T

=

M

S

+

M

A

(

M

TOTAL

=

M

CONTINUOUS

+

M

ACCELERATION

) i

=

DP 1

DP 2

The Continuous Torque M

S

is due to: the friction between table with its ways and with the ballscrew M

F

, to the weight of the table when not moving horizontally M

W

, and to the cutting force of the tool M

C

.

M

S

=

M

F

+

M

W

+

M c

Þ

(

M

CONTINUOUS

=

M

FRICTION

+

M

WEIGHT

+

M

CUTTING

)

Friction torque M

F

:

M

F

=

(

M

)

+

M

)

)

× =

i

1

æ

èç

m g

2

p m

h

+

d

10

ö

ø÷ ×

i

1

M

F

is the torque due to friction and is given in Nm.

m is the table mass in Kg.

g is the gravitational acceleration 9.81 m/s 2 d is the diameter of the ballscrew in mm h is the ballscrew pitch in meters per turn.

µ

is the friction coefficient between the table and the ways it moves on:

Typical

µ

values depending on material: Iron 0.1÷0.2

Turcite 0.05

Roller bearings 0.01÷0.02

Design Ver. 0002 DS - 1

Torque due to weight of the table M w

:

When the move does not move horizontally, but at an angle "

δ

" like in the previous figure, the torque due to the weight of the table must also be considered:

M

W

= m g sin

δ ⋅ h

2

π

% i

M w is the torque due to table weight and is given in Nm.

δ is the incline angle of the ballscrew with respect to the horizontal axis.

% is a mass compensation factor that can vary between 0 and 1.

If the total table weight is compensated for by means of some sort of hydraulic system or counterweights so the motor makes the same effort to move the table up as to move it down, the % factor will be "0". At the other end, if no compensation is applied, % will be

"1".

Torque to the needed cutting force M

C

:

There is a cutting force between the tool and the part and this means a hindrance for moving the table. The torque necessary at the motor to make this movement is calculated as follows:

M

C

=

2

π

1 i

M is the torque due to the cutting force of the tool and is given in Nm.

C

F is the cutting force of the tool and is given in Kg.

g is the gravitational acceleration, 9.81 m/s 2

Motor speed calculation (RPM

MOTOR

).

The machine will need a maximum speed RPM

MOTOR in a linear movement of the table.

Therefore, the motor must have a maximum speed of:

RPM

MOTOR

=

Vmax h

⋅ i

Vmax is the maximum linear speed the table needs.

From the characteristics table for Fagor synchronous motors (chapter SM), select a motor that has:

A Stall torque equal to or greater than the calculated continuous torque M

S

.

A maximum turning speed equal to or greater than the calculated value, RPM

MOTOR

DS - 2 Design Ver. 0002

DS.1.2 SECOND MOTOR PRE-SELECTION

Calculation of Inertia (J)

The next step is to calculate the load that the motor has to move when accelerating; that is, the Moment of Inertia of all the elements it moves. The total inertia J

TOTAL

is due to the load

J

LOAD

and to the rotor of the motor itself J

MOTOR

.

J

TOTAL

=

J

LOAD

+

J

MOTOR

The inertia due to load can be subdivided into that of the table + that of the ballscrew + that of the system used to compensate for non-horizontal axes + that of the pulley or gear used for transmission and which turns with the ballscrew "PULLEY1". All these elements are affected by the reduction factor " i " as shown by the following equation.

The inertia due to the "pulley" that turns with the motor "PULLEY2" is not affected by the "i" factor.

J

LOAD

=

J

TABLE

+

J

BALLSCREW

+

J

PULLEY 1 i

2

+

J

COMPENSATION +

J

PULLEY 2

Next, each one of the inertias are defined:

J

TABLE h

2

π



2

J

BALLSCREW

= d

4

L

32

π α

J

PULLEY 1

=

4

D

P 1

L

32

The resulting inertias are in Kg.m

2

L is the ballscrew length in meters.

L

2

is the width of pulley-2 in meters.

D

P2

is the diameter of pulley-2 in meters.

α

is the material density:

J

PULLEY 2

=

4

D

P 2

L

32 i,

µ

,h,

δ

are data used before.

L

1

is the width of pulley-1 in meters.

D

P1

is the diameter of pulley-1in meters.

700 Kg/m 3 for iron/steel

2700 Kg/m 3 for aluminum

Design Ver. 0002 DS - 3

Motor inertia J

MOTOR

will be:

J

MOTOR

=

J

ROTOR

+

J

BRAKE which are data that may be obtained from the characteristics in chapter SM.

Verify that in the characteristics table the rotor of the motor chosen in the 1st selection has an inertia which meets the following condition:

J

MOTOR

equal to or greater than ( J

LOAD

/K) where K is a factor depending on the application destined for this motor.

The ideal will be to obtain a J

MOTOR

equal to J

LOAD

For a Positioning Axis, the typical value of K will be between 1 and 3

If this requisite is not met, a new motor must be selected which meets the conditions of the

1st selection and the 2nd one.

DS.1.3 THIRD MOTOR PRE-SELECTION

Calculation of the acceleration torque and time

The required acceleration torque is determined by the Total Inertia to be moved and the needed acceleration. This acceleration is given by the Acceleration Time t

AC

which is the time required for the motor to reach the rated speed from resting position (0 rpm).

M

ACCELERATION n

N

is the rated (nominal) motor speed t

AC

is the time it takes the motor to go from "0" rpm to the rated speed.

=

J

TOTAL

2

π

60

⋅ n

N

⋅ t

AC

From the same equation: t

AC

=

J

TOTAL

2

π ⋅ n

N

60

M

ACCELERATION

Calculation of the needed rms torque ( M

RMS

)

The third and last motor selection requires a new data, the RMS Torque:

M

RMS

=

(

M

F

+

M

W

+

M

AC

)

2 t

AC

T

+

(

M

F

+

M

W

) (

T

P +

M

F

+

M

W

+

M

C

)

2 t

C

T where: t

AC

is the acceleration time mentioned earlier.

t

P

is the tool positioning time.

t

C

is the cutting time in a typical machining cycle.

DS - 4 Design Ver. 0002

The typical values for t

AC in machine-tool cycle are:

, t

P

, and t

C t

C

T

=

0 6 t

P

T

=

0 4 t

AC

T

0

M t t

AC t

P t

C

T t

AC t

S

Calculation of the motor peak torque (M

PEAK

)

The required maximum torque is the sum of the Friction, Weight and Acceleration torques:

M

MAX

=

M

F

+

M

W

+

M

AC

For a given acceleration time, we will need specific acceleration torque and maximum torque.

The motor must be able to provide a Peak Torque equal to or greater than the calculated maximum torque.

Verify that the motor chosen in previous selections meets the following condition:

Peak torque equal to or greater than the calculated maximum torque: M

PEAK

Rated torque equal to or greater than the calculated RMS value: M

RATED

>

> M

MAX

M

RMS

Summary of the three pre-selections:

Maximum speed equal to or greater than calculated value (

Motor inertia equal to or greater than inertia: ( J

LOAD

RPM

MOTOR

)

Stall torque equal to or greater than calculated continuous value ( M

CONTINUOUS

/ K)

)

Peak torque equal to or greater than calculated value ( M

MAX

)

Rated torque equal to or greater than calculated RMS value ( M

RMS

)

DS.1.4 DRIVE SELECTION

Once the motor has been selected, check the tables on electrical characteristics at the chapter SM. There are several drives available for each motor and the peak torque obtained with each one of them will be different. A drive has to be chosen whose peak current is greater than the one calculated for the application.

Design Ver. 0002 DS - 5

DS.2 SPINDLE MOTOR AND SERVO DRIVE

On the spindles of machine tools, it is important to maintain a constant turning speed of the spindle. To control this speed, the drive applies torque to the load according to the characteristics of this load as well as to the adjusted accelerations and decelerations.

Procedure to calculated the needed motor power.

1.

Depending on the characteristics of the load, determine the rated values of the needed power (in continuous cycle, instantly and periodically).

2.

Increase the value of that needed power, considering the efficiency of the power transmission and load dispersion.

3.

Select the drive that offers the current needed to govern the motor in all duty cycles for that machine.

DS.2.1 POWER DEMANDED FROM A MOTOR FOR A PARTICULAR

LOAD

To determine the needed motor power, use the following formula:

P

MOTOR

> P

LOAD

+ P

ACCELERATION/DECELERATION

Motor power

(

Power required by a load) +

(Power required for the Accelerations/Decelerations of the Machine)

Torque

Nb

Power

Speed

Load type:

Examples:

Torque/speed characteristics:

Motor power:

Constant power, regardless of speed.

Constant tension coils, Mill spindle, Lathe spindle

The torque decreases from base speed on

Rated drive power will be the one demanded by the load.

DS - 6 Design Ver. 0002

DS.2.1.1

POWER REQUIRED BY THE LOAD

The power demanded from a spindle motor in a turning or machining center is determined by the cutting power.

A good cutting process requires the spindle motor to be working at constant power and with a power range between 1:3 and 1:5.

The powers used for cutting in a lathe, mill, machining center with drilling are calculated as shown below.

For a more accurate calculation of the power required, one must bear in mind different factors such as cutting oil, material, shape of the tools, hardness of the material machined, etc.

For lathe work, a cutting blade forces against the part to be machined, while this turns as shown in the Illustration. The power required, P

C

, is calculated as follows:

P

C

=

*

η

C

=

S dLV

C

*

η

C

(kW)

V

=

π

* DN

S

1000

(m / min) here:

K

S d

L

D

N

S

ηηηηη

C

S

C is the relative cutting resistance in N/mm 2 .

is the depth of the cut in mm.

is the length of the blade, or feedrate per full turn in mm.

is the diameter of the part machined in mm.

is the turning speed of the spindle in r.p.m.

is the mechanical efficiency (varies from 0.7 to 0.85).

is the cutting efficiency, that is, cut volume per kilowatt each minute in cm 3 /kW/min.

In the case of a milling machine, the cutter is mounted on the spindle itself and turns with this to cut the material as shown in the Illustration. The power required in this case P

F

is calculated as follows :

P

F

=

2

*

η

F

=

1000

2 dWf

* S

F

*

η

F

(kW) where: f

ηηηηη

F

S

F

K

S d

W is the relative cutting resistance in N/mm 2 .

is the depth of the cut in mm.

is the width of the cut in mm.

is the feedrate in mm/min.

is the mechanical efficiency (varies from 0.7 to 0.8).

is the cutting efficiency that is, cut volume per kilowatt each minute in cm 3 /kW/min.

Design Ver. 0002 DS - 7

In the case of a drill, the bit is mounted on the spindle itself and turns with this to drill the material as shown in the Illustration. The power required in this case, P

D

, is calculated as below:

P

D

=

M * 2

π

n

* * *

η

D

=

π

* S

D

*

η

D

(kW)

M n

D f

ηηηηη

D

S

D where: is the drill load torque in N·cm.

is the spindle turning speed in r.p.m.

is the diameter of the hole in mm. n is the spindle speed in r.p.m.

is the feedrate in mm/min.

is the mechanical efficiency (varies from 0.7 to 0.85).

is the cutting efficiency, that is, cut volume per kilowatt each minute in cm 3 /kW/min.

In the event of governing a gravitational load, the power required depends very much on the presence or absence of balance weights. (crane or elevator). The power required in this case,

P

GL

, is calculated in the following way:

P

GL

= m

L

* V

6120 *

η

(kW) P

GLC

=

( m

L

− m

C

) * V

6120 *

η

(kW) where:

V m

L is the linear speed in m/min.

is the load mass in kg.

ηηηηη m

C is the mechanical efficiency.

is the balance weight mass in kg.

Governing a frictional load. This is the case of horizontal movements such as a conveyor belt or a movable table. For a friction coefficient m, the power required in this case, P

F calculated as follows:

, is

P

F

=

µ m

L

* V

6120 *

η

(kW) where:

µµµµµ m

L

V

ηηηηη is the friction coefficient.

is the load mass in kg.

is the linear speed in m/min.

is the mechanical efficiency.

DS - 8 Design Ver. 0002

DS.2.1.2

POWER NEEDED FOR THE ACC / DEC OF THE SPINDLE MOTOR

There are three methods to control the acceleration and deceleration process of the machine spindle:

1.- Acceleration limited by time

2.- Different acceleration ramps depending on the speed reached

3.- Limited acceleration and choke. Choke = variation of acceleration.

Adjust

Ta

M e t t t h o d

C o n t t r o l l l l

C o m m e n t s

A c c e l e r a it o n il m i t e d b y it m e

S p e e d i n c o m m a n d c r e s p a s e s e e d il n e a r l y i n i s r e a c h e d it m e u n t li t h e

T h e a c c e l e r a it o n t o r q u e i s c o n s t a n t

Time

Adjust

Time

M e t h o d

C o n t r o l

C o m m e n t t s

D i f f e r e n t s p e e d .

a c c e l e r a it o n s d e p e n d i n g o n

L i v a n e r i a a it r o a c c e n s i n l e r a it o n t r a n s m i a v o i t t e d d i n g a b r u p t t o r q u e .

E m u l a f o r it o n s p e e d o f b y t h e u s i s n g q u a r e r a m s p s i

.

n e f u n c it o n

Adjusts

Time

M e t t h o d

C o n t r o l

C o m m e n t s

A c c e l e r a it o n a n d c h o k e il m i t

P r o g r e s s i v e a c c e l e r a t i o n , a v o i d i n t r a n s m i g t t e a b r u p t d v a t o r q u e .

r i a t i o n s o f

(

A p b e p ll r o s a h c h a p e s q u a r e

) f o r t h e s i n e s p e f u n e d c t i o n

Design Ver. 0002 DS - 9

The capability demanded from the motor is determined by the following formulae:

Capacity required by the Motor in the constant torque area (0 < N

M

< N

B

):

Capacity required by the Motor in the constant torque and constant power area (0 < N

M

< N

Max

) :

P

N

= 

2

π

60



2

1000

2

M t

(kW)

P

N

= 

2

π

60



2

J

M

( N

2

M

+

N

B

2

)

(kW)

2000 t where:

J

M

P

N

N

MAX

N

B t

N

M is the inertia of the load in kg.m

2 as viewed from the motor shaft is the rated power at the base speed, kW.

is the maximum motor speed in rpm.

is the base motor speed in rpm.

is the motor speed in rpm reached after a time period t. is the acceleration time in seconds until the N

M

is reached.

We will now give several examples of calculations using a mechanical specification and for a standard Motor. The results could vary from real ones through mechanical losses, fluctuations in mains voltage, or inaccuracies of mechanical data.

Example.

· Acceleration time:

· Motor inertia:

· Motor base speed:

From 0 to 1500 rpm. in 0.5 sec. (1)

From 0 to 6000 rpm. in 2.5 sec. (2)

J

M

: 0,13 kg·m 2

N

B

: 1500 rpm.

Calculations :

1.- When the speed ranges from 0 to 1500 r.p.m.

P

N

= 

2

π

60



2

J N

M

1000

2 t

M

(kW) =



2

π

60



2

2.- When the speed ranges from 0 to 6000 r.p.m.

2

=

, (kW)

P

N

= 

2

π

60



2

J

M

( N 2

M

+

N 2

B

)

2000 t

(kW) =



2

π

60



2 , *( 6000

2 +

1500

2

)

= 10,89 (kW)

(1)

(2)

DS - 10 Design Ver. 0002

DS.2.2 CALCULATION OF ACCELERATION AND BRAKING TIME

After selecting the mechanical characteristics and the power of the Drive, the acceleration and braking time is calculated as follows.

Constant torque area (0 < N

M

< N

B

): t

1

=

2

π

* J

M

* N

M

60 * T

M

(seg.)

Constant power area (N

B

< N

M

< N

Max

) : t

2

=

2

π

* J

M

( N

2

M

N

B

2

)

(seg.)

120 * T

M

* N

B

Constant torque and constant power area (0 < N

M

< N

Max

) : where: t t t

3 2

2

π

* J

M

( N

2

M

+

120 * T

M

* N

B

N

2

B

)

(seg.)

J

M

T

N

M

MAX

N

B

N

M is the inertia of the load in kg.m

2 as viewed from the motor shaft.

is the rated torque in KW at the base speed.

is the maximum motor speed in rpm.

is the base motor speed in rpm.

is the motor speed in rpm after the acceleration time.

DS.2.3 CALCULATION OF POWER WITH INTERMITTENT LOAD

Forming the Drive to the right dimensions has to be done with the greatest care when the application involves a periodical starting and stopping operation, frequently repeated as in the case of threading with a miller. For a cycle like the one shown in the figure, which includes acceleration and stopping, the equivalent effective torque T

R

S1 dimension given for the Drive torque. The maximum T

P minutes of the Motor.

of Equation 16 must be within the

value is 120% of dimension S2 30

Tr Ts Tf

Ti

Tp

-Tp

Nm

Tc

Time

Time

T

R

=

T

P

2

* ( t r

+ t f

)

+

T

L

2

* t s

(Nm) t c

DS.2.4 DRIVE SELECTION

Once the motor has been selected, check the characteristics curves in the AM chapter.

These curves indicate the power that the various drives can obtain from that motor.

Design Ver. 0002 DS - 11

DS.3 POWER SUPPLY SELECTION

Power demanded to the Power Supply for servo systems with a synchronous motor (axis):

FEED AXES (FXM):

Driver Peak Power

Pp kW

Feed axes:

3

1

2

3

4

Sum of drives peak power (kW)

Pow kW n rpm n

N rpm

Pa kW

Power (characteristics table)

Axis speed in the application (rpm)

Rated speed of the motor (rpm)

Axis Power (kW) n

Pa = Pow · 1.17 · n

N

1

Pp

5.2 kW

9.8 kW

16.4 kW

23 kW

AXD 1.08

AXD 1.15

AXD 1.25

AXD 1.35

Pp

32.9 kW

49.3 kW

65.8 kW

98.7 kW

AXD 2.50

AXD 2.75

AXD 3.100

AXD 3.150

Sum of axes power (kW) where:

Pow Motor power (kW), according to the characteristics tables of the FXM.

1.17

Coefficient combining the performance of the motor (0,9) and that of the drive

(0.95)

Maximum work speed of the motor in that application. (rpm) n n

N

Pv

Nominal motor speed (Nm)

Power dissipated by the drive (W). It depends on the model (see table below)

DS - 12 Design Ver. 0002

Power demanded to the Power supply for servo systems with an asynchronous motor

(spindle):

SPINDLES (SPM):

Maximum Power consumption of the Power Supply (kW)

Spindles:

1

2

Pm (kW)

2

Sum of spindle powers (kW)

Pm (kW)

Spindle Motors

SPM 90L

SPM 90P

SPM 100LBE

SPM 112ME

SPM 112LE

SPM 112XE

Spindle Drive

1.15

1.25

1.35

2.50 2.75 3.100 3.150

5.1

9.5

9.2

8.9

8.7

23

13.1

13.1

12.6

16.7

15.3

24.6

36.2

34.6

36.7

36.4

41.4

49.6

48

57.6

59.7

SPM 132L

SPM 132X

SPM 132XL

SPM 160M

SPM 160L

SPM 180MA

Pm: Power extracted from the

Power necessary for the

spindle drive.

These data include the internal losses of the drive.

where:

Pm Maximum power that the servo system may demand from the Power Supply for each Motor-Drive combination.

It includes the power dissipated by the Drive itself.

Design Ver. 0002 DS - 13

Selection Criteria.

1. The "Power Supply" module must be capable of supplying the power required by the set of servo system connected to it.

First Criterion.

The "Power Supply" module must be capable of supplying the power required by all the Drive + Motor combinations connected to it.

Rated

Power

(S1) kW

< 25

< 65

> 65

Power

Supply

Module

Reference

PS-25A, PS-25B or XPS-25

PS-65A or XPS-65

(*)

(*) Until reaching the needed power from the Power Supply

Very important: When using two Power supplies on the same machine, they have to form two separate groups with their respective drives. Only the Sercos ring, if there is one, may be common to both groups.

NEVER connect the power supplies in parallel.

2. The "Power Supply" module must be able to supply the peak power required by the set of servo systems connected to it.

Second Criterion.

The "Power Supply" module must be capable of supplying the peak power required by all the Drive + Motor combinations connected to it.

Peak

Power kW

< 75

< 195

> 195

Power

Supply Module

Reference

PS-25A or PS-25B

PS-65A

(*) kW Reference

Regenerative

< 55

< 108

> 108

XPS-25

XPS-65

(*)

(*) Until reaching the needed peak power from the Power Supply

Very important: When using two Power supplies on the same machine, they have to form two separate groups with their respective drives. Only the Sercos ring, if there is one, may be common to both groups.

NEVER connect the Power Supplies in parallel.

DS - 14 Design Ver. 0002

4. Use the following sheet to calculate the input transformer, and the section of the mains cables.

Mains voltage

The Fagor Servo Drive system requires 380-460 Vac.

Transformer:

The transformer or autotransformer being used must be of the power:

2

Very important: when using an isolation transformer, the secondary must be of the star type its mid point being accessible so it can be connected to ground.

Power cables for mains connection

Vmains = From 380 to 460 Vac.

Power Supply

4 (kW) x

1000

Vmains 3

=

Rated current through the mains cable:

(Amp)

Axis Compact Module (ACD):

FXM Motor Rated Current =

Spindle Compact Module (SCD):

Maximum SPM Motor Current =

(Amp)

(Amp)

Power Cable

Amp Reference

< 12.2

< 16.5

< 23

< 29

< 40

< 53

< 67

< 83

MPC-4x1.5

MPC-4x2.5

MPC-4x4

MPC-4x6

MPC-4x10

MPC-4x16

25 mm 2 (MPC-4x25 + (2x1))

35 mm 2 (MPC-4x35 + (2x1))

The length of these power cables must be specifically ordered (in meters).

Design Ver. 0002 DS - 15

DS.4 CM-60 SELECTION GUIDE

The CM-60 is a module that increases the electrical capacitance of the power bus in 4 millifarads. It should be installed on machines with very short duty cycles (very repetitive accelerations and decelerations) and with low braking energy. Punch presses are a typical example of this.

The following table indicates how much energy can be stored in Watts second, when the Bus voltage increases from the nominal value (Vbus) to the Ballast circuit activating value

(Vballast

ON

).

Considering the different combinations of power supplies + CM-60 modules and different mains voltages.

W

= ⋅ ⋅

2

(

ON

2 −

Vbus

2

)( Ws ) where:

C comes in farads

V in volts DC

W in watts second (jules)

V mains :

P S-25x

P S-65A

XPS -25

XPS -65

CM-60 + P S-25x

CM-60 + P S-65A

CM-60 + XPS -25

CM-60 + XPS -65

380 V ac 460 V ac

76

81

52

93

507

59

63

96

172

394

511

227

397

421

269 498

W atts ·sec

DS.5 BALLAST RESISTOR SELECTION GUIDE

Calculate the value of:

W m is the energy generated by the braking of each system motor.

Pe is the rms power generated by all braking of all the motors throughout a complete duty cycle.

Based on the following formulae:

Wm

=

Wp

1

Jt

2

Wp m g

∆ h



2

π

60

⋅ n



2

( Ws )

Pe

=

i

W mi

2 t i

T where:

Jt is the total inertia of the servo drive system (motor

+ mechanics) (Kg.m

2 ) n is the turning speed of the motor when the braking starts (rpm)

Wmi is the energy of each braking.

during a cycle of time T (Ws)

Wp is the potential energy lost by the mass of the machine for as long as the braking lasts. Only on ti axes not compensated (Ws) is the braking time where the Wmi energy is generated (sec)

T is the time of full cycle (sec)

∆ h is the height lost when braking (m)

Wmx will be the maximum of all the Wm

DS - 16 Design Ver. 0002

Once the values of Wmx and Pe are calculated, follow these flow charts.

Power supplies for Modular drives.

PS-25A

XPS-25

PS-25B

PS-65A

XPS-65

Wmx >

18kWs (0.6 s)

YES

NO

Pe > 520W

YES

RM-15 or ER-18/1100

NO

Wmx >

35kWs (1 s)

YES

NO

Pe > 400W

YES

RM-15 or ER-18/1100

NO

Wmx >

36kWs (0.6 s)

YES

NO NO

Pe > 600W

YES

RM-15 // RM-15 or

ER-18/1100 // ER-18/1100

Wmx >

50kWs (1 s)

YES

NO NO

Pe > 1800W

YES

RM-15 // RM-15 or

ER-18/1100 // ER-18/1100

Design Ver. 0002 DS - 17

DS - 18

Compact Drives.

SCD, ACD

1.15

SCD, ACD

1.25

SCD, ACD

2.50

Wmx >

2kWs (0.4 s)

YES

NO

Pe > 120W

YES

ER-43/350

NO

Wmx >

3.6kWs (0.45 s)

YES

NO

Pe > 210W

YES

ER-24/750

NO

Wmx >

12kWs (0.7 s)

YES

NO NO

Pe > 240W

YES

ER-24/750 // ER-24/750

SCD, ACD

2.75

Wmx >

12kWs (0.5 s)

YES

NO NO

Pe > 240W

YES

RM-15 // RM-15 or

ER-18/1100 // ER-18/1100

Design Ver. 0002

APPENDIX A:

PARAMETERS

VARIABLES & COMMANDS

Parameters, Variables and Commands Ver. 0002 A - 1

Parameter, variable and command list: (page)

1.

AP5

2.

BV1

BV3

BV7

BV14

O

GROUP APPLICATION “A”. .......................................................................................... 10

(F2001) PlcPrgScanTime ............................................................................................................................... 10

O

O

O

NON-PROGRAMMABLE INPUT-OUTPUT "B" .......................................................... 10

(F201)

(F202)

HaltDrivePin ....................................................................................................................................... 10

HaltDriveDnc ...................................................................................................................................... 10

(F203)

(F204)

DriveEnableDnc ................................................................................................................................ 11

NotProgrammableIOs ..................................................................................................................... 11

3.

CURRENT GROUP “C”. ................................................................................................ 11

CP1

CP3

CP2

CP4

CP5

CP6

CP7

OM (S106)

FMA (F300)

OM (S107)

FMA (F301)

FMA (F302)

FMA (F303)

FMA (F304)

CurrentProportionalGain ................................................................................................................. 11

CurrentDerivativeGain ...................................................................................................................... 11

CurrentIntegralTime ......................................................................................................................... 11

CurrentAdaptationProportionalGain .............................................................................................. 11

CurrentAdaptationIntegralTime ...................................................................................................... 11

CurrentAdaptationLowerLimit ........................................................................................................ 12

CurrentAdaptationUpperLimit ........................................................................................................ 12

CP20.# O (F307.#) CurrentLimit ....................................................................................................................................... 12

CP30.# *O (F308.#) CurrentFilter1TimeConstant ........................................................................................................... 12

CP31.# O (F312.#) CurrentFilter1Damping .................................................................................................................... 12

CV1

CV2 s s

(F309)

(F310)

CurrentUFeedback ........................................................................................................................... 13

CurrentVFeedback ............................................................................................................................ 13

CV3

CV10

CV11

(F311)

Fs (F305)

Fs (F306)

CurrentFeedback .............................................................................................................................. 13

CurrentUOffset .................................................................................................................................. 13

CurrentVOffset ................................................................................................................................... 13

5.

EP1

EP2

EP3

EC1

6.

FP1

FP2

FP20

FP21

FP30

FP31

FP32

FP33

FP34

FP35

4.

DP1 O

DP142 O

DV1

DV9

DV10

DV11

DV14

DV15

DV16

DV31

DV32

DV95

DC1

O

O

DIAGNOSTICS GROUP “D” ......................................................................................... 13

(F400) ErrorsDisables .................................................................................................................................. 13

(S142)

(S11)

(S12)

(S13)

(F404)

(F400)

(F401)

(F402)

(S135)

(S134)

(S95)

(S99)

ApplicationType ................................................................................................................................. 13

Class1Diagnostics (Errors) ........................................................................................................... 13

Class2Diagnostics (Warnings) ..................................................................................................... 14

Class3Diagnostics (OperationStatus) ......................................................................................... 14

FagorDiagnostics ............................................................................................................................. 14

ErrorsInDncFormat ........................................................................................................................... 15

ErrorDisable ...................................................................................................................................... 15

ErrorEnable ........................................................................................................................................ 15

DriverStatusWord .............................................................................................................................. 15

MasterControlWord .......................................................................................................................... 16

DiagnosticMessage ......................................................................................................................... 16

ResetClass1Diagnostics ............................................................................................................... 16

O

O

O

O

SIMULATOR ENCODER GROUP “E”. ........................................................................ 17

(F500)

(F501)

EncoderSimulatorPulsesPerTurn ................................................................................................. 17

EncoderSimulatorI0Position .......................................................................................................... 17

(F502)

(F503)

EncoderSimulatorDirection ............................................................................................................ 17

EncoderSimulatorSetI0 ................................................................................................................... 17

FLUX GROUP “F” .......................................................................................................... 18

OMA (F600)

OMA (F601)

MotorFluxProportionalGain ............................................................................................................. 18

MotorFluxIntegralTime ..................................................................................................................... 18

OMA (F602)

OMA (F603)

FMA (F604)

FMA (F605)

FMA (F606)

FMA (F607)

FMA (F608)

FMA (F609)

MotorBEMFProportionalGain .......................................................................................................... 18

MotorBEMFIntegralTime .................................................................................................................. 18

MotorInductance1 ............................................................................................................................. 18

MotorInductance2 ............................................................................................................................. 18

MotorInductance3 ............................................................................................................................. 18

MotorInductance4 ............................................................................................................................. 18

MotorInductance5 ............................................................................................................................. 18

MotorInductance6 ............................................................................................................................. 18

A - 2 Parameters, Variables and Commands Ver. 0002

9.

IP1.#

IP5

IP10

IP11

IP12

IP13

IV1

IV2

IV10

IV11

FP36

FP37

FP38

FMA (F610)

FMA (F611)

FMA (F612)

MotorInductance7 ............................................................................................................................. 18

MotorInductance8 ............................................................................................................................. 18

MotorInductance9 ............................................................................................................................. 18

FP40.# FMA (F613.#) FluxReduction ................................................................................................................................... 18

GV22

GV23

GV24

GV25

GV26

GV30

GV31

GV32

GV33

GV35

GV36

GV37

GC1

GC2

7.

GP1

GP2

GP3

GP4

GP5

GP6

GP7

GP8

GP9 O

GP10 O

GV2

GV3

GV4 s

GV5

GV7

GV8

GV9

GV10

GV11

GV13

GV14

GV20

GV21

O

O

O

O

O

O

O

s

W

O

W

F

GENERAL GROUP “G” ................................................................................................ 18

(F700) PwmFrequency ................................................................................................................................. 18

(F701)

(F702)

(F703)

(F704)

(F717)

(F235)

(F236)

(S207)

(F234)

(S30)

(F705)

(S380)

(F706)

(S267)

(F707)

(S140)

(S262)

(F708)

(F709)

(F710)

(S219)

(S254)

Feedback1Type ................................................................................................................................. 18

StoppingTimeout .............................................................................................................................. 19

SetNumber ........................................................................................................................................ 19

ParameterVersion ............................................................................................................................ 19

GearRatioNumber ............................................................................................................................ 19

OverloadTimeLimit ........................................................................................................................... 19

OverloadVelocityThreshold ............................................................................................................. 19

DriveOffDelayTime ........................................................................................................................... 19

Feedback2Type ................................................................................................................................. 19

ManufacturerVersion ........................................................................................................................ 19

ParameterChecksum ...................................................................................................................... 20

DCBusVoltage ................................................................................................................................... 20

CodCheckSum ................................................................................................................................. 20

Password ........................................................................................................................................... 20

AccessLevel ...................................................................................................................................... 20

DriveType ............................................................................................................................................ 20

LoadDefaultsCommand ................................................................................................................. 20

SoftReset ........................................................................................................................................... 20

PowerBusStatus ............................................................................................................................... 20

PowerVoltageMinimum ................................................................................................................... 20

IDNListOfParameterSet .................................................................................................................. 20

ParameterSetActual ......................................................................................................................... 20

W

F

W

W

W

W

W

F

(S217)

(F711)

(F712)

(S255)

(S218)

(F713)

(F714)

(F715)

(F716)

(F718)

(F722)

(F2012)

(S264)

(S216)

ParameterSetPreselection ............................................................................................................. 21

ParameterSetAck .............................................................................................................................. 21

ParameterSetStb .............................................................................................................................. 21

GearRatioActual ................................................................................................................................ 21

GearRatioPreselection .................................................................................................................... 21

ParameterSetBit0 ............................................................................................................................. 21

ParameterSetBit1 ............................................................................................................................. 21

ParameterSetBit2 ............................................................................................................................. 21

TMODE_Select .................................................................................................................................. 21

PlcResourceData ............................................................................................................................. 21

KernelResourceData ....................................................................................................................... 21

PlcErrors ............................................................................................................................................ 22

BackupWorkingMemoryCommand ............................................................................................... 22

ParameterSetSwitch ........................................................................................................................ 22

8.

HV1

HV9

HV10

HV11

HARDWARE GROUP “H” ............................................................................................. 22

(S110)

(F806)

(F290)

(F291)

DrivePeakCurrent ............................................................................................................................. 22

ModularOrCompact .......................................................................................................................... 22

VsMSC ................................................................................................................................................ 22

FlashManufacturerCode ................................................................................................................. 22

O

O

O

O

O

O

s s

O

O

GROUP OF INPUTS “I” ................................................................................................. 23

(F900.#) AnalogReferenceSelect .................................................................................................................. 23

(F909) DigitalInputVoltage ........................................................................................................................... 23

(F901)

(F902)

(F903)

(F904)

(F905)

(F906)

(F907)

(F908)

I1IDN ................................................................................................................................................... 23

I2IDN ................................................................................................................................................... 23

I3IDN ................................................................................................................................................... 23

I4IDN ................................................................................................................................................... 23

AnalogInput1 ..................................................................................................................................... 24

AnalogInput2 ..................................................................................................................................... 24

DigitalInputs ...................................................................................................................................... 24

DigitalInputsCh2 ............................................................................................................................... 24

Parameters, Variables and Commands Ver. 0002 A - 3

11.

MP1

MP2

MP13

MP14

MP15

MP16

MP17

MP18

MP19

MP20

MP22

MP24

MP3

MP4

MP5

MP6

MP7

MP8

MP9

MP10

MP11

MP12

10.

KV9

KV12

KV10

KV20

KV21

KV22

KV23

KV24

KV25

KV32

KV36

KV40

KP1

KP2

KP3

KP4

KV2

KV4

KV5

KV6

KV8 s s s s s s

F

O

O

O

W

W

W

W

W

F

MONITORING GROUP “K” .......................................................................................... 25

(F1112)

(F1113)

(F1114)

(F1116)

(F1100)

(F1101)

(S201)

(S383)

(S204)

(S202)

(S205)

(F1102)

(F1103)

(F1104)

(F1105)

(F1106)

(F1107)

(F1108)

(F1109)

(F1111)

(F1115)

DriveI2tErrorEffect ............................................................................................................................. 25

ExtBallastResistance ....................................................................................................................... 25

ExtBallastPower ................................................................................................................................ 25

ExtBallastEnergyPulse .................................................................................................................... 25

DriveTemperature ............................................................................................................................. 25

DriveTmperatureErrorLimit ............................................................................................................. 25

MotorTemperatureWarningLimit .................................................................................................... 25

MotorTemperature ............................................................................................................................ 25

MotorTemperatureErrorLimit .......................................................................................................... 25

CoolingTemperatureWarningLimit ................................................................................................ 25

CoolingTemperatureErrorLimit ...................................................................................................... 25

CoolingTemperature ........................................................................................................................ 25

SupplyPlus5V .................................................................................................................................... 25

SupplyPlus8V .................................................................................................................................... 25

SupplyPlus18V .................................................................................................................................. 25

SupplyMinus5V .................................................................................................................................. 25

SupplyMinus8V .................................................................................................................................. 25

SupplyMinus18V ............................................................................................................................... 25

I2tDrive ................................................................................................................................................ 26

I2tMotor ............................................................................................................................................... 26

ExtBallastOverload ........................................................................................................................... 26

MOTOR GROUP “M” ................................................................................................... 27

O (S141) MotorType ........................................................................................................................................... 27

FMS (F1200) MotorTorqueConstant ...................................................................................................................... 27

FM (S111) MotorContinuousStallCurrent ......................................................................................................... 27

FMS (S109) MotorPeakCurrent ............................................................................................................................. 27

FM (F1201) MotorPolesPairs ............................................................................................................................... 27

FMA (F1202) MotorRatedSupplyVoltage ............................................................................................................... 27

FMA (F1203) MotorPowerFactor ............................................................................................................................. 27

FMA (F1204) MotorConstantPowerEndVelocity ................................................................................................... 27

FMA (F1205) MotorSlip ............................................................................................................................................. 27

FMA (F1206) MotorStatorResistance .................................................................................................................... 27

FMA (F1207) MotorStatorInductance ..................................................................................................................... 27

FMA (F1208) MotorNominalPower ........................................................................................................................ 28

FM (F1209) MotorThermalTimeConstant .......................................................................................................... 28

FM (F1210) MotorTempSensorType .................................................................................................................... 28

FM (F1211) MotorShaft .......................................................................................................................................... 28

FM (F1212) MotorBrake ......................................................................................................................................... 28

FM (F1213) MotorFan ............................................................................................................................................. 28

FMA (F1214) MotorMounting ................................................................................................................................... 28

FMA (F1215) MotorBalancing ................................................................................................................................. 28

FMA (F1216) MotorBearings ................................................................................................................................... 28

FMA (F1218) MotorPowerReduction ..................................................................................................................... 28

FM (F1220) MotorMomentumOfInertia ................................................................................................................ 28

12.

SERCOS GROUP “N” ................................................................................................... 29

NP1 FM (F2200) ReducedActuatedMomentumOfInertiaPercentage .................................................................... 29

NP117 O (S117) ResolutionOfFeedback2 ................................................................................................................. 29

NP118 O

NP121.# O

NP122.# O

NP123 O

NP165 O

NP166 O

NV31

NV33

NV35

NV37

(S118) ResolutionOfLinearFeedback ........................................................................................................ 29

(S121.#) InputRevolutions ............................................................................................................................... 29

(S122.#) OutputRevolutions ............................................................................................................................ 29

(S123) FeedConstant .................................................................................................................................... 30

(S165) DistanceCodedReferenceMarksA ................................................................................................. 30

(S166)

(S301)

DistanceCodedReferenceMarksB ................................................................................................ 30

RealTimeControlBit1IDN ................................................................................................................ 30

(S303)

(S305)

(S307)

RealTimeControlBit2IDN ................................................................................................................ 30

RealTimeStatusBit1IDN .................................................................................................................. 30

RealTimeStatusBit2IDN .................................................................................................................. 30

™ 8„™ Ver. 0002

13.

ANALOG AND DIGITAL OUTPUT GROUP “O” .......................................................... 31

OP1

OP2

OP3

OP4

OP5 O

OP10 O

OP11 O

OP12 O

OP13 O

*O (F1400)

*O (F1401)

*O (F1402)

*O (F1403)

(F291)

(F1404)

(F1405)

(F1406)

(F1407)

OV1

OV2

OV5

OV10

OV11

Os (F1408)

Os (F1409)

O

O

O

(F292)

(F1410)

(F1413)

DA1IDN ............................................................................................................................................... 31

DA2IDN ............................................................................................................................................... 31

DA1ValuePer10Volt .......................................................................................................................... 31

DA2ValuePer10Volt .......................................................................................................................... 31

Prog_OutIDN ..................................................................................................................................... 31

O1IDN ................................................................................................................................................. 32

O2IDN ................................................................................................................................................. 32

O3IDN ................................................................................................................................................. 32

O4IDN ................................................................................................................................................. 32

DA1Value ............................................................................................................................................ 32

DA2Value ............................................................................................................................................ 32

Prog_Out ............................................................................................................................................ 32

DigitalOutputs ................................................................................................................................... 33

DigitalOutputsCh2 ............................................................................................................................ 33

14.

GROUP FOR THE POSITIONING DRIVE “P” ............................................................. 34

PV26

PV27

PV28

PV47

PV51

PV53

PV58

PV59

PV60

PP1.# O

PP10

PP11

PP12 s

PP22

PP23

PP25 s s

PP41.# O

PP42.# O

(F1300.#) HomingVelocitySlow ........................................................................................................................ 34

(F1310) ProcessBlockMode .......................................................................................................................... 34

(F1311)

(F1312)

FeedrateOverrideLimit ..................................................................................................................... 34

PositioningVelocityDefault .............................................................................................................. 34

(F1322)

(F1323)

(F1325)

(S41.#)

(S42.#)

JogVelocity ......................................................................................................................................... 34

JogIncrementalPosition .................................................................................................................. 34

InPositionTime .................................................................................................................................. 34

HomingVelocityFast ......................................................................................................................... 34

HomingAcceleration ........................................................................................................................ 35

PP49

PP50

PP52

PP54

PP55

Os (S49)

Os (S50)

Os (S52)

Os (S54)

O (S55)

PositivePositionLimit ....................................................................................................................... 35

NegativePositionLimit ..................................................................................................................... 35

ReferenceDistance1 ........................................................................................................................ 35

ReferenceDistance2 ........................................................................................................................ 35

PositionPolarityParameters ........................................................................................................... 35

PP57

PP58

PP76

O (S57)

Os (S58)

(S76)

PositionWindow ................................................................................................................................ 36

Backlash ............................................................................................................................................ 36

PositionDataScalingType ................................................................................................................ 36

PP103 Os (S103)

PP104.# (S104.#)

ModuloValue ...................................................................................................................................... 37

PositionKvGain ................................................................................................................................. 37

PV13

PV14

PV15

PV16

PV17

PV18

PV19

PV20

PV21

PV24

PP115 O (S115)

PP147 (S147)

PP150 Os (S150)

PP151 Os (S151)

PP159 O (S177)

PositionFeedback2Type .................................................................................................................. 37

HomingParameter ........................................................................................................................... 37

ReferenceOffset1 ............................................................................................................................. 38

ReferenceOffset2 ............................................................................................................................. 38

MonitoringWindow ............................................................................................................................ 38

PP177 O

PP178 O

PP216.#

(S177)

(S178)

AbsoluteDistance1 ........................................................................................................................... 38

AbsoluteDistance2 ........................................................................................................................... 38

(S296.#) VelocityFeedForwardPercentage ................................................................................................... 38

PP217.# (S348.#) AccelerationFeedForwardPercentage .......................................................................................... 38

PP243.# O (S393.#) ModuloComandMode ...................................................................................................................... 39

W

W

W

W

W

W

W

W

W

(F1313)

(F1314)

(F1315)

(F1316)

(F1317)

(F1318)

(F1319)

(F1320)

(F1321)

(F1324)

KernelOperationMode ..................................................................................................................... 39

KernelAutoMode ............................................................................................................................... 39

KernelStartSignal ............................................................................................................................. 39

KernelStopSignal ............................................................................................................................. 39

KernelResetSignal ........................................................................................................................... 39

KernelAbortSignal ............................................................................................................................ 39

KernelManMode ................................................................................................................................ 39

JogPositiveSignal ............................................................................................................................. 39

JogNegativeSignal ........................................................................................................................... 40

FeedrateOverrideEqualCero .......................................................................................................... 40

Ws (F1326)

(F1327)

(F1328)

Ws (S47) s (S51) s (S53)

Ws (S258)

Ws (S259)

Ws (S260)

ProgramPositionOffset .................................................................................................................... 40

KernelInitError ................................................................................................................................... 40

KernelExecError ................................................................................................................................ 40

PositionCommand ........................................................................................................................... 41

PositionFeedback1 .......................................................................................................................... 41

PositionFeedback2 .......................................................................................................................... 41

TargetPosition ................................................................................................................................... 41

PositioningVelocity ........................................................................................................................... 41

PositioningAcceleration .................................................................................................................. 41

Parameters, Variables and Commands Ver. 0002 A - 5

PV108 W

PV115

PV123

PV136

PV142

PV143

PV173 s

PV175 O

(S108)

(S315)

(S323)

(S336)

(S342)

(S343)

(S173)

(S175)

PV176 O

PV189 s

(S176)

(S189)

PV193 Os (S193)

PV200 O (S400)

PV203 (S403)

PV204 W (S404)

PV207 (S407)

PV208

PC146

PC148

(S408)

(S146)

(S148)

PC171

PC172

(S171)

(S172)

15.

QP1

QP11

FeedrateOverride .............................................................................................................................. 41

PositioningVelocityGreaterLimit ..................................................................................................... 41

TargetPositionOutsideOfTravelRange .......................................................................................... 41

InPosition ........................................................................................................................................... 41

TargetPositionAttained ..................................................................................................................... 41

InterpolatorHalted ............................................................................................................................. 41

MarkerPositionA ................................................................................................................................ 42

DisplacementParameter1 .............................................................................................................. 42

DisplacementParameter2 .............................................................................................................. 42

FollowingError ................................................................................................................................... 42

PositioningJerk ................................................................................................................................. 42

HomeSwitch ...................................................................................................................................... 42

PositionFeedbackStatus ................................................................................................................. 42

PositionCommandStatus ............................................................................................................... 42

HomingEnable .................................................................................................................................. 42

ReferenceMarkerPulseRegistered ............................................................................................... 43

NCControlledHoming ...................................................................................................................... 43

DriveControlledHoming ................................................................................................................... 43

CalculateDisplacement_C ............................................................................................................. 43

DisplacementToTheReferenceSystem ........................................................................................ 43

SERCOS COMMUNICATION GROUP “Q” ................................................................. 44

(S1) ControlUnitCycleTime ...................................................................................................................... 44

(F2000) SercosMbaud .................................................................................................................................... 44

RP53

RP54

RV1

RV2

RV3

RV4

RV5

RV6

RV7

RV8

RV51

RV52

RV54

RC1

16.

RP1

RP2

RP3

RP4

RP5 O

RP6.# O

RP10 O

RP51

RP52

O

O

O

O

ROTOR SENSOR GROUP “R” ................................................................................... 45

(F1500) FeedbackSineGain ........................................................................................................................... 45

(F1501) FeedbackCosineGain ...................................................................................................................... 45

Os (F1502) FeedbackSineOffset ......................................................................................................................... 45

Os (F1503) FeedbackCosineOffset .................................................................................................................... 45

(F1504) FeedbackResolverRhoCorrection ................................................................................................. 45

(F1505.#) FeedbackErrorDisable .................................................................................................................... 45

(F1514) Feedback2Interface .......................................................................................................................... 45

(F1550) Feedback2SineGain ........................................................................................................................ 45

(F1551) Feedback2CosineGain ................................................................................................................... 45

F s s

s

F

Os (F1552) Feedback2SineOffset ...................................................................................................................... 45

Os (F1553) Feedback2CosineOffset ................................................................................................................. 45 s (F1506) FeedbackSine ................................................................................................................................... 45

(F1507) FeedbackCosine .............................................................................................................................. 45

(F1508) FeedbackRhoCorrection ................................................................................................................. 45

(F1509) FeedbackRadius .............................................................................................................................. 46

(F1515) EncoderType ...................................................................................................................................... 46

(F1510) EncoderError ..................................................................................................................................... 46

(F1511) StegmannMotorType ........................................................................................................................ 46

(F1512) CircleAdjust ........................................................................................................................................ 46

O

(F1556)

(F1557)

Feedback2Sine ................................................................................................................................. 46

Feedback2Cosine ............................................................................................................................ 46

(F1559) Feedback2Radius ............................................................................................................................ 46

(F1509) EncoderParameterStoreCommand .............................................................................................. 47

17.

SP1.# *

SP2.# *

SPEED GROUP “S”. ...................................................................................................... 48

(S100.#) VelocityProportionalGain ................................................................................................................. 48

(S101.#) VelocityIntegralTime ......................................................................................................................... 48

SP4.# *

SP5.# *

SP6.# O

SP7.# O

SP10.# O

SP11

SP12

SP20.#

SP21.#

SP30

SP31

(S211.#)

(S91.#)

VelocityAdaptationProportionalGain .............................................................................................. 48

(S212.#) VelocityAdaptationIntegralTime ...................................................................................................... 48

(S209.#) VelocityAdaptationLowerLimit ......................................................................................................... 48

(S210.#) VelocityAdaptationUpperLimit ......................................................................................................... 48

VelocityLimit ....................................................................................................................................... 48

FMA (S113) MotorMaximumSpeed ...................................................................................................................... 48

FM (F1600) MotorRatedSpeed ............................................................................................................................. 49

(F31.#) VoltageRpmVolt ................................................................................................................................. 49

*s

*s

(F81.#) RpmRpmVolt ..................................................................................................................................... 49

(F1603) AnalogInputOffset1 ........................................................................................................................... 49

(F1604) AnalogInputOffset2 ........................................................................................................................... 49

™ 8„™ Ver. 0002

19.

WV1

WV2

WV3

WV4

WV5

WV6

WV7

WV8

WV9

20.

XV0

XV1

XV2

SP40.# O

SP41.# O

SP42 O

SP43 O

SP60.# O

SP62.# O

SP64.# O

SP61.# O

(S125.#) VelocityThresholdNx ......................................................................................................................... 49

(S157.#) VelocityWindow ................................................................................................................................. 49

(S124) StandStillWindow ............................................................................................................................. 50

(S43) VelocityPolarityParameter ............................................................................................................... 50

(S138.#) AccelerationLimit .............................................................................................................................. 50

(F1606.#) AccelerationLimit2 ............................................................................................................................ 50

(F1608.#) AccelerationLimit3 ............................................................................................................................ 50

(F1605.#) AccelerationLimitVelocity2 .............................................................................................................. 50

SP63.# O

SP65.# O

SP70 O

SP80.# O

SP100.# O

SV1

SV2

SV3

SV4

SV5

SV7

SV8 s s

(F1607.#)

(F1609.#)

(F1610)

AccelerationLimitVelocity3 .............................................................................................................. 50

EmergencyAcceleration .................................................................................................................. 50

AccelerationOnEmergency ............................................................................................................. 50

(S349.#) JerkLimit ............................................................................................................................................. 51

(F1611.#)

Ws (S36) s (S40)

(S332)

(S330)

(S331)

(F1612)

(F1613)

AccelerationLimitOn ......................................................................................................................... 51

VelocityCommand ............................................................................................................................ 51

VelocityFeedback .............................................................................................................................. 51

nFeedbackMinorNx .......................................................................................................................... 52 nFeedbackEqualNCommand ........................................................................................................ 52 nFeedbackEqual0 ............................................................................................................................ 52

VelocityCommandFinal ................................................................................................................... 52

VelocityCommandBeforeFilters ..................................................................................................... 52

18.

TP1

TP2

TP85

TV1

TV2

TV3

TV10

TV50

TV60

TV100

O s s s

TORQUE AND POWER GROUP "T". ........................................................................... 53

Os (S126)

Os (S158)

TorqueThresholdTx .......................................................................................................................... 53

PowerThresholdPx ........................................................................................................................... 53

s

(S85)

(S80)

(S84)

(F1701)

(S333)

(F1700)

(S337)

(F1702)

TorquePolarityParameter ................................................................................................................ 53

TorqueCommand ............................................................................................................................. 53

TorqueFeedback ............................................................................................................................... 53

TorqueFeedbackPercentage .......................................................................................................... 53

TGreaterTx ......................................................................................................................................... 53

PowerFeedback ................................................................................................................................ 54

PGreaterPx ......................................................................................................................................... 54

TorqueStatus ..................................................................................................................................... 54

W

INTERNAL GENERATOR GROUP “W” ....................................................................... 55

(F1800) GeneratorShape ............................................................................................................................... 55

W (F1801)

Ws (F1802)

O (F1803) s

W

(F1804)

(F1805)

W

W

(F1806)

(F1807)

Ws (F1808)

GeneratorPeriod ............................................................................................................................... 55

GeneratorAmplitude ......................................................................................................................... 55

GeneratorType ................................................................................................................................... 55

GeneratorOutput ............................................................................................................................... 55

GeneratorDutyCycle ......................................................................................................................... 55

GeneratorWaves ............................................................................................................................... 55

GeneratorOn ...................................................................................................................................... 55

GeneratorOffset ................................................................................................................................ 55

MISCELLANEOUS GROUP “X” ................................................................................... 56

(S0) NullId ................................................................................................................................................... 56

(F1900)

(F1901)

One ...................................................................................................................................................... 56

Zero ..................................................................................................................................................... 56

Parameters, Variables and Commands Ver. 0002 A - 7

A - 8

NOTATION USED :

15

16

17

18

11

12

13

14

19

1

2

7

8

9

10

5

6

3

4

[Group][Type][Index][.Range] where:

Group: Identifying character of the logic group to which the parameter or variable belongs.

There are the following groups of parameters:

GROUPS OF PARAMETERS AND VARIABLES

FUNCTION GROUP

Operating Mode

Control signals

Application

Terminal box

Current control loop

Error diagnosis

Encoder simulator

Flux control loop

General of the system

Current

Diagnosis

Encoder

Flux

General

System hardware

Analog and digital inputs

Temperatures and voltages

Motor properties

Sercos

Analog and digital outputs

Positioning

Rotor sensor properties

Velocity control loop

Torque and power parameters

Internal function generator

Parameter setting assistance

Hardware

Inputs

Monitoring

Motor

Sercos

Outputs

Position

Rotor

Speed

Torque

Internal generator

Miscellaneous

N

O

P

R

H

I

K

M

LETTER

A

B

C

D

E

F

G

S

T

W

X

Type: Character identifying the type of data which the information corresponds to.

May be: a parameter defining the system operation (P), a variable that can be read and modified dynamically (V), or a command that carries a specific action (C).

The difference between parameter and variable is that the parameter has a programmable initial value and that, except rarely, their value changes only affect after saving the parameters and resetting the drive.

Index: Character identifying the parameter or the variable within the group to which this belongs.

Set: Lots of parameters are divided into "ranges". Each range is a set of parameters that can configure the system differently. This only makes sense for parameters, not for variables. See section "Parameter Sets and Gear Ratios" in chapter AP.

Definition examples:

SP10.4: “S” Group, (P) Parameter, (Nº) 10,

CV21: “C” Group, (V) Variable, (Nº) 21.

GC1: "G" Group, (C) Command, (Nº) 1.

Set 4.

Parameters, Variables and Commands Ver. 0002

Identification of parameters:

After the name, the following characteristics are described:

Parameter sets.

Immediate effect.

Modifiable variable.

Access level.

Sign.

Related to the motor.

Motor type.

# Parameter expandable in sets.

* Parameter modifiable on-line.

W It is a modifiable variable (from any level).

F Fagor.

O OEM.

(USER by default) s With sign.

M Value set by MP1 -S141- MotorType

S Synchronous. A Asynchronous. (exclusively).

The identifier between ( ) corresponds to the SERCOS interface.

The ones starting with an "S" correspond to the SERCOS standard and those starting with an

"F" to Fagor. The numbers for the SERCOS standard of Fagor parameters and variables are obtained by adding 32768 to their index, for example:

The F24 is referred to in SERCOS as S(24+32768); that is: S32792.

By the same token, the SERCOS numbers for the range extended parameters are obtained by adding 4096 to each range, for example:

Parameter VelocityLoopProportionalGain (SP1) is extended in ranges; thus the SERCOS number for SP1.0 will be S100, for SP1.1 will be S4196, for SP1.2 will be S8292, etc...

Fagor parameters with range extension are affected by these considerations.

Examples:

- parameter MP4, is identified with:

MP4 FMS (S109) MotorPeakCurrent

It means that it is a parameter which belongs to the Motor group, it cannot be expanded in sets or modified on line and it can only be modified from the Fagor access level unsigned by the MotorId and it only makes sense for synchronous motors. Its ID number in the SERCOS interface is 109.

- variable SV7, is identified with:

SV7 s (F1612) VelocityCommandFinal

It means that a signed read-only Variable (without W). Its SERCOS interface ID number is 1612+32768=34380.

Warning:

The physical units and ranges for each parameter or variable of this appendix are those used by the DOS based ddssetup monitor for PC as well as by the programming module.

Parameters, Variables and Commands Ver. 0002 A - 9

1.

GROUP APPLICATION “A”.

Function:

Valid values:

AP5 O

Function:

Valid values:

It determines the way it operates as far as the system configuration is concerned.

Bit Name

————————————————————————————-

4

3

2

1, 0 (LSB)

It sets the activation of Feedforward ( when working with position command)

= 1 Feedforward active

= 0 Feedforward cancelled

It determines whether the motor feedback or direct feedback is used.

= 1 Direct X feedback

= 0 Motor feedback

Determine whether it is a velocity or position command.

= 10 Velocity command (without position loop)

= 11 Position command

See the section on "Velocity or Position Drive" in the GSU chapter of this manual.

1..15 (3 by default, position loop with motor feedback).

(F2001) PlcPrgScanTime

It determines the repetition period of the main PLC module (PRG)

4, 8, 12, 16 or 20 ms (4 ms, by default)

2.

NON-PROGRAMMABLE INPUT-OUTPUT "B"

Groups the variables related to the non-programmable hardware control signals and logic variables associated with the Halt and Drive_Enable functions through the serial line.

Activating the Halt function means setting the velocity command to zero while keeping the rotor locked (with torque). It can be activated by means of an electrical signal at certain digital inputs of the drive using the monitoring program through the serial line or Sercos interface.

The Halt function is activated (stops the motor) when applying zero volts to the electrical input assigned to variable BV1, when requested from the monitoring program (variable BV3=0), or when requested from the PLC of the CNC via Sercos (bit 13 of DV32 set to 0).

BV1 O

Function:

Default value:

Example:

Version:

BV3 O

Function:

Default value:

Example:

(F201)

(F202)

HaltDrivePin

Controls the Halt function through an electrical signal. BV1 is assigned to the parameter IP10-IP13 corresponding to the digital input that will be used as Halt.

1 (it has no effect).

IP11 = BV1 (digital input 2 performs the Halt function. In other words, applying 0V to pin 2 with respect to pin 5, activates the Halt function and the motor stops).

Available from version 02.01 on.

HaltDriveDnc

Controls the Halt function through the serial line.

1 (it has no effect).

BV3 = 0 (activates the Halt function).

Activating the DriveEnable function enables the current to flow through the Motor.

It can be deactivated by means of an electrical signal at the control connector X2 of the Drive, from the monitoring program through the serial line or via Sercos interface.

The DriveEnable function is deactivated (removes motor torque) when applying zero volts at that electrical input, when requested from the monitoring program (variable BV7 = 0), or when requested from the PLC of the

CNC via Sercos (bit 14 of DV32 -variable DRENA at the PLC- is set to 0).

A - 10 Parameters, Variables and Commands Ver. 0002

S p e e d E n a b le P in

S p e e d E n a b le (S e rc o s )

-S P E N A -

(X 2 )

D V 3 2 -S 1 3 4 -

(b it 1 5 )

O R

S p e e d E n a b le

F u n c tio n

D riv e E n a b le P in

D riv e E n a b le D n c

D riv e E n a b le (S e rc o s )

-D R E N A -

H a ltD riv e P in

H a ltD riv e D n c

H a lt (S e rc o s )

(X 2 )

B V 7 -F 2 0 3 -

D V 3 2 -S 1 3 4 -

(b it 1 4 )

B V 1 -F 2 0 1 -

B V 3 -F 2 0 2 -

D V 3 2 -S 1 3 4 -

(b it 1 3 )

O R

O R

D riv e E n a b le

F u n c tio n

H a lt F u n c tio n

BV7 O

Function:

Default value:

Example:

BV14

Function:

(F203) DriveEnableDnc

Controls the DriveEnable function through the serial line.

1 (it has no effect).

BV7 = 0 (deactivates the DriveEnable function, -removes motor torque-)

(F204) NotProgrammableIOs

Example:

Note:

Version:

Indicates the logic values of the electrical control signals of the Drive.

-24 volts at this electrical input mean a logic "1" at the bits of this variable.-

Bit Signal

———————————————————————————————————

4 (MSB)

3

Lsc_Status (at the intermodular Bus X1)

Error_Reset

2

1

0 (LSB)

DR_OK (at the microprocessor, not at the pins of X2)

Speed_Enable & Syst.Speed_Enable (Drive and Power Supply)

Drive_Enable

BV14 = 18 which is the same as binary 10010. This means that "Lsc_Status" and

Speed_Enable & Syst.Speed_Enable are active

The DR_OK bit not always coincides with the actual output at the control connector X2 because there are logic circuits beyond the microprocessor which can change this value (for example: Errors in the power circuits).

Available from version 02.01 on.

3.

CURRENT GROUP “C”.

CP1

CP3

OM (S106)

FMA (F300)

CurrentProportionalGain

CurrentDerivativeGain

Function :

Valid values:

CP2 OM (S107)

Value of the proportional / derivative action of the current PID.

0..8000

CurrentIntegralTime

Function :

Valid values:

CP4

CP5

FMA (F301)

FMA (F302)

Value of the integral action of the current PID.

0..2000

CurrentAdaptationProportionalGain

CurrentAdaptationIntegralTime

Function:

Valid values:

Default values:

Adapting to the value of the proportional /integral action of the current PI.

10 .. 1000% in other words, The action of the PI at low speeds may be between one tenth to ten times the action at high speeds.

CP4*CP1 / 1000 must be smaller than the maximum value of CP1.

CP5*CP2 / 1000 must be smaller than the maximum value of CP2.

100% (constant proportional / integral action at any speed)

Parameters, Variables and Commands Ver. 0002 A - 11

CP6 FMA (F303)

Function:

Valid values:

CurrentAdaptationLowerLimit

Is the upper rpm limit of the speeds considered "low".

Must be smaller than: CP7

CP7 FMA (F304)

Function:

Valid values:

CurrentAdaptationUpperLimit

Is the lower rpm limit of the speeds considered "high".

Must be: smaller than SP10 greater than CP6

CP20.# O

Function:

Valid values:

Default value:

CP30.#

Function:

*O

Valid values:

(F307.#) CurrentLimit

Limit of the current command that reaches the system's current loop.

See the internal configuration diagram. Imposed by the user.

0..300 (depends on the Driver being connected) Amperes RMS

On drives with FXM motors, CP20 takes the smaller of the Drive's and motor peak current values.

On the SPM, it takes the maximum Drive current value. In applications requiring great threading power, the value of CP20 may be up to 15% greater than the maximum current of the drive.

(F308.#) CurrentFilter1TimeConstant

It sets the natural frequency of the low passing filter that acts upon the current command. It is only applicable on servo drive systems with FXM motors, not with SPM motors.

0, filter disabled

1, Natural frequency at 800 Hz

3, Natural frequency at 600 Hz

2,

4,

Natural frequency at 700 Hz

Natural frequency at 500 Hz

5, Natural frequency at 400 Hz

7, Natural frequency at 200 Hz

6,

8,

Natural frequency at 300 Hz

Natural frequency at 100 Hz

> 10 sets the natural frequency (not implemented yet)

0, filter disabled

Operative from version 02.02 on, expanded in version 04.01

Default value:

Version:

CP31.#

Function:

O

Valid values:

Default value:

Version:

(F312.#) CurrentFilter1Damping

It sets the damping factor of the low passing filter that acts upon the current command. The greater the value of this parameter, the slower the response of the filter. A damping factor of 07 (default value of this parameter) is considered to closer follow the filter's theoretical curve.

500...50000

7071

Operative from version 04.01 on

A - 12

Synchronous Motor

Adapter- Current-PI

K p

C P 1

0 .5 *C P 1

C P 2

T i

Speed

C P 1 -S 1 0 6 - C u rre n tP ro p o rtio n a lG a in

C P 2 -S 1 0 7 - C u rre n tIn te g ra lT im e

Asynchronous Motor

Adapter-Current-PID

C P 4 *C P 1

C P 2

T i

C P 5 *C P 2

C P 1

K p

Speed

C P 6 C P 7

C P 4 -F 3 0 1 - C u rre n tA d a p ta tio n P ro p o rtio n a lG a in

C P 5 -F 3 0 2 - C u rre n tA d a p ta tio n In te g ra lT im e

C P 6 -F 3 0 3 - C u rre n tA d a p ta tio n L o w e rL im it

C P 7 -F 3 0 4 - C u rre n tA d a p ta tio n U p p e rL im it

Parameters, Variables and Commands Ver. 0002

CV1

CV2 s s

Function:

Valid values:

CV3

Function:

Valid values:

(F309)

(F310)

(F311)

CurrentUFeedback

CurrentVFeedback

Display of the feedback value of the U / V current.

-200..200 Amperes (instantaneous values).

CurrentFeedback

Display of the motor rms current.

-200..200 Amperes rms

CV10

CV11

Fs

Fs

Function:

Valid values:

Default value:

(F305)

(F306)

CurrentUOffset

CurrentVOffset

Current feedback offset compensation for the U / V phase.

-5000..5000 (depends on the Drive connected)

0, This value is factory measured and adjusted.

4.

DIAGNOSTICS GROUP “D”

DP1

Function:

O

DP142 O

Function:

DV1

Function:

Example:

Version:

(F400) ErrorsDisables

Using 13 32-bit, it registers the possible disabling of each error. This parameter may be modified through variables DV15 -F2101- and DV16 -F2102-.

(S142) ApplicationType

For information only. It contains the type of application the Drive is being used for

(e.g. spindle, rotary axis, etc.)

(S11) Class1Diagnostics (Errors)

The DV1 variable contains the numeric data which in 16-bit binary code represents the error status according to the table below. Bit (from MSB to LSB) name, code at front display of the module.

13

12

11

10

Bit Name Error

————————————————————————————-

15 (MSB)

14

ManufacturerSpecificError

Class1Reserved

Rest.

TravelLimit

ComunicationError

ExcessivePositionDeviation

PowerSupplyPhaseError

400->499

205

3

2

5

4

7

6

9

8

1

0 (LSB)

UndervoltageError

OvervoltageError

FeedbackError

ControlVoltageError

CoolingErrorShutdown

MotorOvertempShutdown

AmplifierOvertempShutdown

OverloadShutdown

307

304,306

OvercurrentError 212

ErrorInElectronicCommutationSystem 213->214

600->699

100->105

106

108

107

201, 202, 203

Bit = 0

Bit = 1 no error error

DV1 = 32804 same as 1000000000100100 in binary. Therefore, there is

FeedbackError, a MotorOvertempShutdown, and another one of the manufacturerSpecificError type

Available from version 02.01 on.

Parameters, Variables and Commands Ver. 0002 A - 13

DV9

Function:

Example:

Version:

DV10

Function:

Example:

Version:

DV11

Function:

Example:

Version:

(S12) Class2Diagnostics (Warnings)

The DV9 variable contains the numeric data which in 16-bit binary code represents the warning status according to the table below. Bit (from MSB to LSB).

Bit Name Warning

————————————————————————————-

15,14

13

Reserved

TargetPositionOutsideTheTravelZone (warning 13)

3

2

12, 11,10

9,8

1

0 (LSB)

Reserved

Reserved

CoolingErrorShutdown

MotorOvertempShutdown

AmplifierOvertempShutdown

OverloadShutdown

(warning 3)

(warning 2)

(warning 1)

(warning 0)

Bit = 0

Bit = 1 no warning warning

DV9 = 8 same as 0000000000001000 in binary. Therefore, there is

CoolingErrorShutdown warning

Available from version 02.01 on.

(S13) Class3Diagnostics (OperationStatus)

The DV10 variable contains a numeric data which in 16-bit binary code represents the status of the logic marks (operation status) according to the table below. From

MSB to LSB.

Bit Marks Meaning

————————————————————

15,14,13,12 Reserved

11,10,9,8

7

6

Reserved

TV60 (S337)

PV136

| TV50 | > TP2

| PV189 | > PP57

5

4

3

2

1

0 (LSB)

Reserved

Reserved

TV10 (S333)

SV3 (S332)

SV5 (S331)

SV4 (S330)

| TV2 | > TP1

| SV2 | < SP40

| SV2 | < SP42

SV2 = SV1

(F404)

DV10 = 14 same as 0000000000001110 in binary.

Therefore, SV5, SV3 and TV10 have been activated.

Available from version 02.01 on.

FagorDiagnostics

Variable DV11 contains a numeric value which in 16-bit binary code represents the status of some of the most interesting variables of the Drive. Bits (from the least to the most significant ones).

Bit Variable Name

————————————————————————————-

15,14,13

12

11

10

9

8

7,6,5,4

3,2,1,0

Reserved

TV60 (S337)

TV10 (S333)

SV3

SV5

(S332)

(S331)

SV4 (S330)

GV21 (S254)

GV25 (S255)

PGreaterPx

TGreaterTx nFeedbackMinorNx nFeedbackEqual0 nFeedbackEqualNCommand

ParameterSetActual

GearRatioActual

DV11 = 1280 (0000010100000000 in binary)

Therefore, it is operating with Range 0, Set 0, it follows the command OK, it is stopped and under the Nx, Tx and Px thresholds.

Available from version 03.01 on.

A - 14 Parameters, Variables and Commands Ver. 0002

DV14

Function:

DV15

Function:

O

Example:

Units:

DV16

Function:

O

Example:

DV31

Function:

Example:

Version:

(F400) ErrorsInDncFormat

For reading all the errors currently active. See appendix B for the errors.

(F401) ErrorDisable

When writing an error identifying number into this variable, it is disabled.

Even if the reason for the error is generated again, it is not triggered and the Drive keeps on running normally.

If the drive shows error 108 "motor overheating", after writing the value of 108 into the

DV15 -F2101- variable, saving it and resetting the drive, the Status Display of the drive will no longer indicate this error.

Natural number, identifying the type of error. See appendix B for the errors.

(F402) ErrorEnable

When writing an error identifying number into this variable, it is enabled. It cancels the disabling effect of the DV15 -F2101-.

Using the previous example, when writing the value of 108 into the DV16 -F2102variable, saving it and resetting the drive, the Status Display of the drive will show this error again.

(S135) DriverStatusWord

The DV31 variable contains the numeric data which in 16-bit binary code represents various aspects of the system status according to the table below. From the MSB to the LSB. This variable communicates with the CNC through the Sercos interface. Bits

15 and 14 are assigned to PLC variables DRSTAF and DRSTAS respectively.

Bit Meaning Possible values

————————————————————————————-

15,14 PowerAndTorqueStatus Bits (15,14) Meaning

————————————

(0,0)

(0,1)

(1,0)

DoingInternalTests

ReadyForPower

PowerOn

(1,1) TorqueOn

Indicates at which point of the start-up sequence the drive is.

error 13

12

11

9,8

WarningChangeBit

OperationStatusChangeBit

ActualOperationMode

Real Time StatusBit1

Bits (9,8) Meaning

————————————

(0,0) InPrimaryMode

(0,1) InSecondary1Mode

(1,0)

(1,1)

InSecondary2Mode

InSecondary3Mode

7

6

5

4,3,2,1,0

Real Time StatusBit0

ChangeBitCommands

Reserved

DV31 = 11479 same as the binary 0010110011010110 and it means that it is running an internal test (DoingInternalTests), has an error, etc.

Available from version 02.01 on.

Parameters, Variables and Commands Ver. 0002 A - 15

DV32

Function:

Example:

DV95

Function:

DC1

Function:

Version:

(S134) MasterControlWord

The DV32 variable contains the numeric data which in 16-bit binary code represents the status of various control signals that the CNC sends to the Drive through the

Sercos interface. Bits (from the least to the most significant ones).

Bits 15 and 14 correspond to the values of the digital PLC outputs SPENA and

DRENA respectively (at the PLC of the 8050/55 CNC).

Bit Name

—————————————

15

14

SpeedEnable (SPENA)

DriveEnable (DRENA)

13

12,11,10

9,8,7,6,5

4,3,2,1,0

Halt

Reserved

Reserved

Reserved

DV31 = 1110000000000000 in binary. The CNC "wants" the motor to turn following the velocity command.

(S95) DiagnosticMessage

Not being used at this time

(S99) ResetClass1Diagnostics

Reset the errors appearing on the display. Available on the command menu of the programming module "DDS PROG MODULE" as ResetClass1Diagnostics.

Available from version 02.01 on.

A - 16 Parameters, Variables and Commands Ver. 0002

5.

SIMULATOR ENCODER GROUP “E”.

EP1 O

Function:

Valid values:

Default value:

(F500) EncoderSimulatorPulsesPerTurn

Number of pulses per rotor turn generated by the encoder simulator.

1..16360 (Integer)

1250

EP2 O

Function:

Valid values:

Default value:

(F501) EncoderSimulatorI0Position

Rotor position where the encoder simulator generates the home marker pulse (Io).

1..EP1 (Integer)

1

EP3

Function:

Valid values:

Default value:

EC1

Function:

O

O

(F502) EncoderSimulatorDirection

With this parameter the turning direction of the simulated encoder is selected.

This parameter may be modified with the "C" command from the "ddssetup".

0 and 1, clockwise and counterclockwise rotation respectively.

0 (clockwise ).

(F503) EncoderSimulatorSetI0

The execution of this command sets the current rotor position as the home point (I

0

).

Available in the command menu of the programming module "DDS PROG MODULE" as EncoderSimulatorFixI0Command .

A

B

Io

CLOCKWISE TURN

EP3 = 0

90° PHASE-SHIFT

Encoder Simulator

X3(1)

X3(2)

X3(3)

X3(4)

X3(5)

X3(6)

A

A

B

B

Io

Io

X3(11)

GND

H V2-X3 Board Id

EP1 -F500-

EncoderSimulatorPulsesPerTurn

EP2 -F501-

EncoderSimulatorI0Position

EP3 -F502-

EncoderSimulatorDirection

EP3 = 1

90° PHASE-SHIFT t

A

B

Io t

Example

EP1 -F500-

EP2 -F501-

EP3 -F502-

= 1250

= 20 0

= 0

Rotor

1125

1000

1250

125

Io

250

875

750

625

500

375

Parameters, Variables and Commands Ver. 0002 A - 17

6.

FLUX GROUP “F”

FP1

FP2

FP20

FP21

OMA (F600)

OMA (F601)

OMA (F602)

OMA (F603)

Function :

Valid values:

Default value:

MotorFluxProportionalGain

MotorFluxIntegralTime

MotorBEMFProportionalGain

MotorBEMFIntegralTime

Value of the proportional / integral action of the PI for flux and Back EMF.

0..32000

0

FP30

FP31

FP32

FP33

FP34

FP35

FP36

FP37

FP38

Function:

Valid values:

Default value:

FMA (F604)

FMA (F605)

FMA (F606)

FMA (F607)

FMA (F608)

FMA (F609)

FMA (F610)

FMA (F611)

FMA (F612)

MotorInductance1

MotorInductance2

MotorInductance3

MotorInductance4

MotorInductance5

MotorInductance6

MotorInductance7

MotorInductance8

MotorInductance9

Values of the magnetic saturation curve of the stator iron.

0.1 .. 10%

1%

FP40.# FMA (F613.#)

Function:

Valid values:

Default value:

FluxReduction

Indicates the percentage of magnetizing current that circulates through the motor when applying load. It reduces the amount of motor noise and its overheating when turning without load. To cancel the effect of this parameter, set it to 100%.

1 .. 100%

100%

7.

GENERAL GROUP “G”

GP1 O

Function:

Units:

Valid values:

GP2 O

Function:

Valid values:

Default value:

(F700) PwmFrequency

Selects the communications frequency of the IGBTs.

KHz

4 ( by default on Asynchronous motors)

8 ( by default on Synchronous motors)

(F701) Feedback1Type

Type of motor feedback.

0- Sinewave encoder 1-Resolver 2-Squarewave encoder, TTL

5-Heidenhain encoder (ERN 1387) for Siemens motors, 1FT6 family

0-Sinewave encoder

Drive Enable

Function

Speed Enable

Function

Torque "ON"

GP3 t t t

A - 18 Parameters, Variables and Commands Ver. 0002

GP3

Function:

O

Valid values:

Default value:

GP4 O

Function:

Valid values:

Default value:

Version:

(F702)

(F703)

StoppingTimeout

After deactivating the SPEED_ENABLE and once the GP3 time period has elapsed, if the motor has stopped, the TORQUE is automatically deactivated and an Error-4.

If the motor stops within the GP3 time period, the TORQUE is also deactivated, but without issuing an error.

0..65535 (depends on the motor) msec.

500 on axes, 5000 on spindles

SetNumber

Number of useful parameter sets. They are numbered from zero on. Only the number of sets limited by GP4 may be activated.

1..8 (From a single Set up to all of them)

1 (a single Set)

Available from version 02.01 on.

GP5

Function:

Version:

(F704) ParameterVersion

It stores the version of the motor parameter table. Read only.

Available from version 02.01 on.

GP6 O

Function:

Possible values:

Default value:

Version:

(F717) GearRatioNumber

Number of useful gear ratios. The useful gear ratios must be numbered from zero on. Only a number of gear ratios limited by this parameter GP6 can be activated.

1..8 (From a single gear ratio up to all of them)

1 (A single gear ratio)

Available from version 03.01 on.

GP7

Function:

O

Function:

Valid values:

Default value:

Version:

GP8

Function:

O

Valid values:

Default value:

Version:

GP9 O

Valid values:

Default value:

Version:

(F235) OverloadTimeLimit

When the overload conditions exceed this time period, the error is issued. See GP8.

0..10000 milliseconds. With GP7 =0 this protection is disabled.

200

Available from version 02.04 on.

(F236)

(S207)

OverloadVelocityThreshold

Sets the speed threshold under which the motor is considered to be stopped in terms of overload detection. See GP7.

0..1000 rpm

100 (Asynchronous Motors), Rated Speed (Synchronous Motors).

Available from version 02.04 on.

DriveOffDelayTime

After stopping the motor by disabling the SpeedEnable function or by activating an error, the DriveEnable function is disabled (involving PWM-OFF) with a delay set by

GP9. It is very useful when the axes do not have a blocking brake. See electrical diagrams in chapter IN.

0..65535 milliseconds.

0 (after stopping the motor due to SpeedEnable or ErrorStop, the motor torque is removed)

Available from version 03.03 on.

GP10 O

Function:

Valid values:

Default value:

Version:

(F234) Feedback2Type

It determines the type of electrical signal received from direct feedback through X3.

0- No feedback.

1- Square TTL signal

2- 1 Vpp sinewave signal or differential (double ended) square TTL signal.

0- (No feedback)

Available from version 04.01 on

GV2

Function:

(S30) ManufacturerVersion

Display of the current version and the type of drive (axis or spindle).

Parameters, Variables and Commands Ver. 0002 A - 19

GV3

Version: s

GV4

Function:

Version:

GV5

Version: s

(F705) ParameterChecksum

Available from version 01.04 on.

(S380) DCBusVoltage

Reports on the voltage at the Power Bus (in volts).

Available from version 02.01 on.

(F706) CodCheckSum

Available from version 01.04 on.

GV7

Function:

GV8

W

Function:

Valid values:

GV9

Function:

Valid values:

GV10

Function:

O

Valid values:

GV11

Function:

W

GV13

Function:

Valid values:

GV14

Function:

Units:

Version:

F

GV20

Function:

GV21

Function:

Valid values:

Default value:

Version:

(S267) Password

Variable used to enter the password to change access levels. The system will change to the access level corresponding to the password entered.

(F707) AccessLevel

Informs of the current access level.

1-User, 2-OEM, 3-FAGOR.

(S140) DriveType

Informs of which is the Drive reference.

All of them according to the coding given in Appendix C.

(S262) LoadDefaultsCommand

Motor identification and initialization. Assigning a reference identifying a particular motor to this variable (see appendix C) configures the parameters related to the motor to govern it and the rest of the parameters to their default values.

See the section on "Motor Identification" of chapter on GSU.

The references for the motors indicated in appendix C.

(F708) SoftReset

Variable for doing a Reset by software. See the section on "Reset, initialization process" of the chapter on GSU.

(F709) PowerBusStatus

Indicates whether there is voltage at the power BUS or not.

0 / 1 no / yes

(F710) PowerVoltageMinimum

While torque is active, if the bus voltage is lower than GV14, error 307 is issued.

Volts

Available from version 02.01 on.

(S219) IDNListOfParameterSet

It offers the list of parameters expandable in sets.

(S254) ParameterSetActual

Determines which one the active parameter set used by the system.

0..7 (Eight Sets possible)

0 (Set 0)

Available from version 02.01 on.

A - 20 Parameters, Variables and Commands Ver. 0002

GV22 W

Function:

Valid values:

Default value:

Version:

GV23

GV24

Function:

F

W

Valid values:

Version:

GV25

(S217)

(F711)

(F712)

ParameterSetPreselection

Determines which is the parameter set that will be active when receiving the admission signal (GV24)

0..7 (Eight Sets possible)

0 (Set 0)

Available from version 02.01 on.

ParameterSetAck

ParameterSetStb

(S255)

Variables related to the change of active Set. "GV24" must be set to "1" ("Strobe") in order to be able to change the set with GV30, GV31, GV32. When the set change is effective, the Drive indicates so through the GV23 variable.

If GV24 is not assigned to any digital input, it keeps a value of "1" (active) and therefore all the changes in GV30-32 have an immediate effect on the active Set.

0 / 1 (inactive / active)

Available from version 02.01 on.

GearRatioActual

Function:

Valid values:

Default value:

Version:

GV26 W (S218)

Indicates which is the active Gear Ratio in the software.

0..7 (Eight gear ratios possible)

0 (Gear Ratio 0)

Available from version 03.01 on.

GearRatioPreselection

Function:

Valid values:

Default value:

Version:

GV30

GV31

GV32

Function:

W

W

W

GV36

Function:

Determines which will be the active Gear Ratio (software) when making the change through the Sercos interface.

0..7 (Eight gear ratios possible)

0 (Gear Ratio 0)

Available from version 03.01 on.

(F713)

(F714)

(F715)

ParameterSetBit0

ParameterSetBit1

ParameterSetBit2

Boolean variables forming the number identifying the active set.

GV32 is the most significant bit (MSB) and GV30 the least (LSB). To make the active set change effective, GV24 must be enabled.

By assigning these four variables to parameters IP10-IP13 makes it possible to control which will be the active set by means of electrical signals.

0 / 1, (assigned to the IP corresponding to (0 / 24 Vdc) respectively)

GV32=1, GV31=1 and GV30=0, represent the sixth range (6).

Available from version 02.01 on.

Valid values:

Example:

Version:

GV33 F

Function:

Valid values:

Default value:

Version:

GV35

Function:

(F716) TMODE_Select

It is a useful variable for testing the hardware of the Sercos ring.

0, Normal operation mode.

1, Zero Bit String.

2, Continuous light output.

0

Available from version 03.01 on.

(F718) PlcResourceData

Parameter to be used internally by the system. It defines the location and structure of the PLC resources in the Drive memory so all the modules can access those resources. These resources are: registers, counters, marks, images of the marks, images of the inputs and outputs.

(F722) KernelResourceData

Parameter to be used internally by the system. It defines the location and structure of the resources of the MC software in the Drive memory so all the modules can access those resources. These resources are: user variables and arrays

Parameters, Variables and Commands Ver. 0002 A - 21

GV37

Function:

GC1

Function:

GC2

Function:

(F2012) PlcErrors

When the PLC indicates through the display Status a compiling or execution error, this variable indicates its exact meaning. See PLC manual.

(S264) BackupWorkingMemoryCommand

Transfers parameters contained in RAM memory to Flash memory. Available on the command menu of the programming module "DDS PROG MODULE" as

BackupWorkMemoryProcedureCommand.

(S216) ParameterSetSwitch

Execution of the change of ranges and parameter Sets.

8.

HARDWARE GROUP “H”

HV1

Function:

Valid values:

HV9

Function:

Valid values:

HV10

Function:

HV11

Function:

(S110) DrivePeakCurrent

Identifies the power of the Drive module (Peak current for an FXM)

8, 15, 25, 35, 50, 75, 100, 150

(F806) ModularOrCompact

Shows whether the Drive is modular or compact.

0-Modular 1-Compact

(F290) VsMSC

It informs of the different hardware possibilities.

(F291) FlashManufacturerCode

Indicates the code of the manufacturer of the flash memories used in the drive.

A - 22 Parameters, Variables and Commands Ver. 0002

9.

GROUP OF INPUTS “I”

IP1.#

IP5

Function:

Valid values:

Function:

O

O

(F900.#) AnalogReferenceSelect

Selects the analog input used as velocity command.

1: Analog input 1 (by default)

2: Analog input 2

(F909) DigitalInputVoltage

Its four least significant bits configure the digital inputs of the 8I-16O and 16I-8O cards to operate at an input voltage of 5 Vdc or 24 Vdc.

The card for connectors X6 and X7 cannot be configured by this parameter.

Bits 0 (LSB) and 1 configure the inputs of slot SL1.

Bit 0 configures the group of inputs I1-I8.

Bit 1 configures the group I9-I16.

Bits 2 and 3 configure the inputs of slot SL2.

Bit 2 configures the group I17-I24.

Bit 3 configures I25-I32.

0: inputs configured for 24 Vdc (by default at all four bits)

1: inputs configured for 5 Vdc

Operative from version 04.01 on

Valid values:

Version:

IP10

IP11

IP12

IP13

Function:

O

O

O

O

Default value:

Examples:

Version:

(F901)

(F902)

(F903)

(F904)

I1IDN

I2IDN

I3IDN

I4IDN

Contain the identifiers of the parameters or variables which will be assigned the logic value of the electrical signal going into the Drive through: pin-1 (referred to pin-5) for IP10 pin-2 (referred to pin-5) for IP11 pin-3 (referred to pin-5) for IP12 pin-4 (referred to pin-5) for IP13

0 (not assigned)

IP10 = GV24 (pin 1 referred to 5, is the Strobe for Set selection)

IP11 = BV1

IP12 = 0

(pin 2 referred to 5, performs the Halt-hardware function)

(pin 3 referred to 5, performs no function)

The parameters IP12 and IP13 are available from version 02.01 on.

Physical Inputs

X7(5)

X7(4)

X7(3)

X7(2)

V (+)

V (-)

V (+)

V (-)

X6(1)

X6(2)

X6(3)

X6(4)

IV1 -F00905-

H V5 - A1 Board Id

Analog

IP1 -F00900-

IV2 -F00906-

Digital

IP10 -F00 90 1-

IP11 -F00 90 2-

IP12 -F00 90 3-

IP13 -F00 90 4-

IV10 -F00907-

IP 1 = 1

IP 1 = 2

Parameters, Variables and Commands Ver. 0002 A - 23

IV1

IV2

Function: s s

Valid values:

Version:

IV10

Function:

O

Valid values:

Example:

Version:

IV11

Function:

O

Valid values:

Example:

Version:

(F905)

(F906)

AnalogInput1

AnalogInput2

They monitor de input voltages for analog input 1 (pins 4-5 of X7) and analog input 2

(pins 2-3 of X7).

Their values cannot be changed. They are read-only variables.

-10..10 Volts

Operative from version 02.01 on

(F907)

(F908)

DigitalInputs

The IV10 variable contains a numeric data, in binary code, which represents the status of the digital inputs present in slot SL1.

• If slot SL1 is occupied by connectors X6 and X7, these inputs correspond to parameters IP10-13 (four digital inputs).

• If slot SL1 is occupied by any of the I/O cards 16DI-8DO or 8DI-16DO these inputs correspond to PLC resources I1-I16.

0..65535 ($FFFF)

We read that IV10 = 3 whose binary code is: 0011. This means that inputs 1 and 2 of connector X6 are active (receiving 24 Vdc) and inputs 3 and 4 are inactive (at 0 Vdc).

Operative from version 02.01. Renewed in version 04.01

DigitalInputsCh2

The IV11 variable contains a binary coded numeric data which represents the status of the digital inputs present in slot SL2.

• Slot SL1 can only be occupied by one of the I/O cards: 16DI-8DO or

8DI-16DO. When working with the PLC, these inputs correspond to resources

I17-I32.

0..65535 ($FFFF)

We read that IV11 = 30 whose binary code is 00011110. This means that inputs I18,

I19, I20, I21 are active and the rest are inactive (at 0 Vdc).

Operative from version 04.01 on.

Drive Module (example)

SL2 SL1

1

I17

I19

X11

I21

I23

9

1

I25

I27

X12

I29

I31

9

16DI-8DO

1

O17

X13

O19

O21

O23

9

I26

I28

I30

I32

O18

O20

O22

O24

I18

I20

I22

I24

X8

1

I7

9

8DI-16DO

1

O1

I1

I3

I5

X9

O3

O5

O7

9

1

X10

9

I2

I4

I6

I8

O9

O10

O11

O12

O13

O14

O15

O16

O2

O4

O6

O8

Drive Module (example)

SL2 SL1

1 1

I17

I19

X8

I21

I23

9

8DI-16DO

1

O17

X9

O19

O21

O23

9

1

X10

O25

O27

O29

O31

9

O26

O28

O30

O32

O18

O20

O22

O24

I18

I20

I22

I24

X6

13

1

X7

11

P2

P1

A1

I1

I3

I2

I4

O1

O2

O3

O4

A - 24 Parameters, Variables and Commands Ver. 0002

10. MONITORING GROUP “K”

Function:

Valid values:

Version:

KV5

KV6

KV8

W

W

Function:

Valid values:

Version:

KV9

KV12

W

W

Function:

Valid values:

KV10

KV20

KV21

KV22

KV23

KV24

KV25 s s s s s s

Function:

Version:

KP1

Function:

F

Valid values:

Default value:

Version:

KP2 O

(F1112) DriveI2tErrorEffect

It determines whether the i 2 t causes the motor to stop or it limits its current to the nominal value.

0, Stops the system.

1, limits the current through the motor to its rated value.

0 (Stops the system)

Available from version 03.01 on.

Function:

Valid values:

Version:

(F1113) ExtBallastResistance

It contains the Ohm value of the External Ballast resistor of a Compact Drive. This is useful for the i 2 t protection of that resistor.

0..6K5 (0 by default)

Operative from version 03.07 on

KP3

Function:

O

Valid values:

Version:

KP4 O

Function:

Valid values:

Version:

KV2

KV4 W

(F1114)

It contains the value of the power of the External Ballast resistor of a Compact Drive.

This is useful for the i 2 t protection of that resistor.

0..65 kw (0 by default)

Operative from version 03.07 on.

(F1116)

ExtBallastPower

ExtBallastEnergyPulse

It contains the value of the energy pulse that can be dissipated by the External Ballast resistor of a Compact Drive. This is useful for the i 2 t protection of that resistor.

0..65 kWs (0 by default)

Operative from version 03.07 on.

(F1100)

(F1101)

DriveTemperature

DriveTmperatureErrorLimit

Read / write of the limits set by the user for the warning and temperature error of the

Driver.

5..100 degrees centigrade ( o C)

Operative from version 02.01 on.

(S201)

(S383)

(S204)

(S202)

(S205)

(F1102)

(F1103)

(F1104)

(F1105)

(F1106)

(F1107)

(F1108)

MotorTemperatureWarningLimit

MotorTemperature

MotorTemperatureErrorLimit

Same for the motor. (KV6 is only applicable for AXM motors)

0..130 degrees centigrade ( o C)

Operative from version 02.01 on

CoolingTemperatureWarningLimit

CoolingTemperatureErrorLimit

Same for the drive and its temperature

0..110 degrees centigrade ( o C)

CoolingTemperature

SupplyPlus5V

SupplyPlus8V

SupplyPlus18V

SupplyMinus5V

SupplyMinus8V

SupplyMinus18V

Monitoring of heatsink temperature (degrees centigrade ( o C)) and of power supply voltages present at the module.

Operative from version 02.01 on

Parameters, Variables and Commands Ver. 0002 A - 25

KV32

KV36

Function:

F

Version:

KV40

Function:

Version:

(F1109)

(F1111)

I2tDrive

I2tMotor

Variables being used internally by the system. They measure the levels of the internal load of the i 2 t calculation at the Drive and at the motor as "the percentage used of the maximum.

Operative from version 03.01 on. Renewed in version 04.01

(F1115) ExtBallastOverload

It shows the percentage of load on the External Ballast resistor in a Compact Drive.

This is useful for the i 2 t protection of that resistor. A value over 100% in this variable will trigger error 301.

Operative from version 03.07 on.

A - 26 Parameters, Variables and Commands Ver. 0002

11. MOTOR GROUP “M”

MP1

Function:

O (S141) MotorType

Motor identification and initialization. Assigning to this parameter a reference identifying a particular motor (see appendix C) configures the motor related parameters to govern that motor.

See the section on "motor identification" in the GSU chapter.

To govern a non-Fagor motor or to modify some of these "M" parameters, MP1 must be set to a value starting with "0", for example: MP1=0supermotor.

The references appearing in appendix C for the motors.

Valid values:

MP2 FMS (F1200) MotorTorqueConstant

Function :

Valid values:

Contains the torque constant of the synchronous motor (motor torque depending on the rms current).

0.1..1000 Nm/Arms.

MP3 FM (S111)

Function:

Valid values:

MotorContinuousStallCurrent

Rated motor current.

0.1..200 (it depends on the motor connected) Amperes RMS

MP4 FMS (S109)

Function:

Valid values:

MotorPeakCurrent

Peak current of the synchronous motor. Is the amount of current never to be exceeded at the motor.

0.1..300 (it depends on the motor connected) Amperes RMS

MP5 FM (F1201)

Function:

Valid values:

MotorPolesPairs

Number of pairs of poles

1..24 (integer)

MP6 FMA (F1202)

Function:

Valid values:

MotorRatedSupplyVoltage

Is the rated voltage of the Asynchronous motor.

10..400 RMS Vac

MP7 FMA (F1203)

Function:

Valid values:

MotorPowerFactor

Power factor of the asynchronous motor

1..99 hundredths

MP8 FMA (F1204)

Function:

Valid values:

MotorConstantPowerEndVelocity

Maximum speed for the constant power zone in S1

10..10000 rpm

MP9 FMA (F1205)

Function:

Valid values:

MotorSlip

Slippage on the asynchronous motor.

10..200 tenths of rpm.

MP10 FMA (F1206)

Function:

Valid values:

MotorStatorResistance

Stator Resistance.

1..20000 milliOhms

MP11 FMA (F1207)

Function:

Valid values:

MotorStatorInductance

Stator inductance.

0.1..1000 mH.

Parameters, Variables and Commands Ver. 0002 A - 27

MP12 FMA (F1208)

Function:

Valid values:

MotorNominalPower

Nominal Power.

1..2000 tenths of Kw.

MP13 FM (F1209)

Function:

Valid values:

MP14 FM (F1210)

MotorThermalTimeConstant

Motor Thermal Time Constant.

1..200 minutes.

MotorTempSensorType

Function:

Valid values:

Identifies the sensor of the Fagor motor

0 - SPM and FXM: Triple, sensitive between 130°C and 160°C

1 - AXM: Simple, sensitive between 0 and 155 ºC

MP15

Function:

FM (F1211) MotorShaft

Offers information about the shaft type installed on the motor.

On FXM motors:

MP15 = 0 means that the shaft has a standard keyway

MP15 = 1 means that it does not have a keyway.

On SPM motors:

MP15 = 0 means that it is a normal shaft.

MP15 = 1 means that the shaft is sealed (against oil from the gear box).

MP15 = 2..9 it is a special shaft supplied upon request.

MP16

Function:

FM (F1212) MotorBrake

It indicates whether the motor has a brake (MP16 = 1) or not (MP16 = 0).

MP17

Function:

FM (F1213) MotorFan

It indicates whether the motor has a fan (MP17 = 1) or not (MP17 = 0).

It only makes sense on FXM motors because the SPM motors always carry a fan.

MP18

Function:

FMA (F1214) MotorMounting

It indicates how the SPM motor is mounted. The roller bearings of that motor will be designed for that particular way of mounting.

MP18 = 0 for a horizontal mount B3/B5

MP18 = 1 for a vertical mount with the shaft facing down V1/V5

MP18 = 2 for a vertical mount with the shaft facing up V3/V6

MP19

Function:

FMA (F1215) MotorBalancing

It indicates the balancing degree of the motor.

MP19 = 0 -> standard "degree: "S"..

MP19 = 1 -> better balancing degree: SR.

MP20 FMA (F1216) MotorBearings

Function: It indicates the type of roller bearings.

MP20 = 0 -> normal bearings.

MP20 = 1 -> high speed bearings.

MP22 FMA (F1218)

Function:

Valid values:

Default value::

MP24 FM (F1220)

MotorPowerReduction

Limits the maximum power of an asynchronous motor.

0..100%

100%

MotorMomentumOfInertia

Function:

Valid values:

Default value:

Motor inertia.

1..10000 Kgr/cm 2

10 Kgr/cm 2

A - 28 Parameters, Variables and Commands Ver. 0002

12. SERCOS GROUP “N”

NP1

Function:

FM (F2200)

Valid values:

Default values:

ReducedActuatedMomentumOfInertiaPercentage

(Parameter not available at this time). It shows the ratio between load inertia and that of the motor rotor. To calculate this ratio one must consider the mechanical transmission ratio (gear ratio) between the movement of the load and the rotation of the motor.

This parameter is A MUST for the internal processing of the acceleration feedforward in the position loop.

0 .. 1000%

0%

NP117

Function:

Units:

O

Valid values:

Default values:

(S117) ResolutionOfFeedback2

It indicates feedback resolution for the direct feedback at X3.

If it is a linear feedback (a scale), the signal period is given in microns. For Fagor scales (graduated glass), this resolution is 20 microns. In other words, S117=20

If it is a rotary encoder, this resolution is given in lines per turn.

1..2147483647

2048 (2048 lines per turn of the rotary encoder)

NP118

Function:

Units:

O

Valid values:

Default values:

(S118) ResolutionOfLinearFeedback

It indicates what linear feedback resolution is used as Direct Feedback. If the feedback signal is modified by an external multiplier, the value of this parameter must reflect the effect of that multiplier.

If it is a linear scale, the feedback signal period is given in decimicrons. In the case of Fagor linear glass scales this resolution is 20 microns (S118 = 200). In the case of Fagor Steel tape scales this resolution is 100 microns (S118 = 1000).

When applying a "x10" multiplying factor to a Fagor glass scale (20 microns), then:

S118 = 20 decimicrons.

1..2147483647

2048

NP121.# O

NP122.# O

Function:

Valid values:

Default values:

(S121.#)

(S122.#)

InputRevolutions

OutputRevolutions

They define the transmission ratio between the motor shaft and the final axis moving the machine. For example, if the motor turns 5 times for every 3 turns of the ballscrew, these parameters should be set as follows:

(S121) = 5

(S122) = 3

1..32767 turns

1 turn for both parameters (direct coupling)

OUTPUT PULLEY

BALLSCREW TABLE

Motor

Motor

Speed

INPUT PULLEY

Speed

Example:

Diameter of the output pulley = 25.75 mm

Diameter of the input pulley = 15.3 mm

NP121 = 2575

NP122 = 1530

Gear ratio =2575/1530 =1.683

Ballscrew pitch = 5 mm

NP123 = 5 milimeters

Parameters, Variables and Commands Ver. 0002 A - 29

NP123

Function:

Valid values:

Default values:

NP165

Function:

O

O

(S123) FeedConstant

They define the linear movement of the machine and the axis moving it. For example, if the table moves 4 mm for every turn of the ballscrew. This parameter should be set as S123 = 40000

In the case of a rotary axis, NP123 = 3600000, (360 degrees per turn)

1..214 m

5000 microns (5 mm per turn)

(S165) DistanceCodedReferenceMarksA

Valid values:

Default values:

When the linear scale has distance-coded reference marks, this parameter indicates the distance between two "coded" consecutive reference marks . For example, for

Fagor glass scales, it is 20.02 mm.

1001, 2002

1001

NP166

Function:

O

Valid values:

Default values:

(S166) DistanceCodedReferenceMarksB

When the linear scale has distance-coded reference marks, this parameter indicates the distance between two consecutive reference marks. For example, for Fagor glass scales, it is 20 mm.

1000, 2000

1000

NV31

NV33

NV35

NV37

Function:

(S301)

(S303)

(S305)

(S307)

RealTimeControlBit1IDN

RealTimeControlBit2IDN

RealTimeStatusBit1IDN

RealTimeStatusBit2IDN

Internal system variables.

A - 30 Parameters, Variables and Commands Ver. 0002

13. ANALOG AND DIGITAL OUTPUT GROUP “O”

OP1

OP2

Function:

Valid values:

Default values:

OP3

OP4

Function:

*O

*O

*O

*O

(F1400)

(F1401)

DA1IDN

DA2IDN

They identify the internal analog variables of the Drive which will be reflected at the electrical outputs and will be affected by the OP3 and OP4 gains respectively.

Channel 1 (pins10-11 of X7) and channel 2 (pins 8-9 of X7).

Assign a "0" value to OP1 and 7 or OP2 to allow forcing the value of the electrical signals by means of OV1 and/or OV2.

Name of any variable or parameter.

SV1 in the case of OP1, and SV2 in the case of OP2.

(F1402)

(F1403)

DA1ValuePer10Volt

DA2ValuePer10Volt

Units:

Valid values:

Default value:

Example:

They define the gains of channel 1 (pins 10-11 of X7) and channel 2 (pins 8-9 of X7).

These gains are given through the value of the variable corresponding to an output of

10 V.

Those of the variable being displayed.

1..65535

1000

If OP1=SV2 (VelocityFeedback, in rpm) and OP3=3000. This means that when SV2 =

3000 rpm. The analog voltage will be 10 V (pins 10-11 of X7). It will maintain this rpm/

Volt ratio for the full range of ±10V.

OP5

Function:

O

Default value:

Example:

Version:

(F291) Prog_OutIDN

Identifies the boolean variable which will be reflected at the digital output Prog_OUT of the Compact Drive (pins 8-9 of connector X2).

0 (not assigned), In that situation, Prog_OUT may be forced with OV5.

OP5 = TV100 (the contact is closed when there is torque)

Operational from version 02.03 on.

X6

X7

X2

1

13

P2

P1

1

11

1

10

X7(11)

X7(10)

±10 Volts

max.

X7(9)

X7(8)

Physical Analog Outputs

OV1 -F01408-

DA1Value Channel 1

Ref

D/A

OP1 -F01400- DA1IDN

OP3 -F01402-

DA1ValuePer10Volts

OV2 -F01409-

DA2Value

Ref

D/A

Channel 2

OP2 -F01401- DA2IDN

OP4 -F01403-

DA2ValuePer10Volts

Variable examples for OP1 and OP2

SV2 -S00040- VelocityFeedback

SV7 -F01612- VelocityCommandFinal

TV1 -S00080- TorqueCommand

TV2 -S00084- TorqueFeedback

CV3 -F00311- CurrentFeedback

.... and more

X2(8)

X2(9)

Physical Digital Output (Compact Drive)

OP5 -F01411- Prog_OutIDN

OV5 -F01412- Prog_Out

Parameters, Variables and Commands Ver. 0002 A - 31

OP10

OP11

OP12

OP13

Function:

O

O

O

O

Default value:

Examples:

Version:

(F1404)

(F1405)

(F1406)

(F1407)

O1IDN

O2IDN

O3IDN

O4IDN

They identify the boolean system variables that will appear at the digital outputs 1 / 2 /

3 and 4 through pins (6,7), (8,9), (10,11) and (12,13) of connector X6.

Units: Name of the parameter or variable to be displayed. Boolean only.

0 (not assigned)

OP11 = TV100 (the contact between pins 8 and 9, is closed when there is torque)

OP12 and OP13 are operational from version 02.01 on and with the new I/O board

(X6 has 13 pins).

OV1

OV2

Function:

Os (F1408)

Os (F1409)

Valid values:

Example:

Note:

OV5 O

DA1Value

DA2Value

(F292)

These variables are used for forcing the value of the electrical signal at the analog outputs of connector X7.

This can be done only when assigning a "0" value to these outputs (OP1, OP2).

OV1 gives the value of the output through channel 1 (pins 11 and 10 of connector X7).

OV2 gives the value of the output through channel 2 (pins 9 and 8 of connector X7).

-10000...10000 Millivolts

When OP1=0; assign a value of 2000 to OV1 and there will be 2 Volts at pins 11/10 of

X7.

It does not make sense to read these values.

Prog_Out

Function:

Valid values:

Example:

Version:

The OV5 variable contains the binary data representing the status of the Prog_OUT output of the compact drive. With two operation modes:

Read mode: Value of the digital output Prog_OUT.

Write mode: Value forced onto this output if OP5 has no function assigned to it

(OP5 = 0).

0 / 1

We read that OV5 = 1 while OP5 = TV100, this means that there is torque.

If with OP5 = 0 we write OV5 = 1, we will close the Prog_OUT contact.

Operational from version 02.03 on.

1

X6

X7

13

P2

P1

1

11

X6(6)

X6(7)

X6(8)

X6(9)

X6(10)

X6(11)

X6(12)

X6(13)

Physical Digital Outputs

1 OP10 -F01404- O1IDN

2 OP11 -F01405- O2IDN

3 OP12 -F01406- O3IDN

4 OP13 -F01407- O4IDN

Variable examples for OP10-OP13

SV3 -S 00332- n<nx

SV4 -S00330- n=ncommand

SV5 -S00331- n<nmin

TV10 -S00333- T>Tx

TV60 -S00337- P>Px

TV100 -F01702- T active

GV13 -F00709- PowerBusOn

BV 7 -F00203- DriveE nableDnc

... and more

A - 32 Parameters, Variables and Commands Ver. 0002

OV10

Function:

Valid values:

Default value:

Example:

Version:

OV11

Function:

O

O

Valid values:

Default value:

Example:

Version:

(F1410) DigitalOutputs

The OV10 variable contains a binary coded numeric value which represents the status of the digital outputs present in slot SL1.

• If slot SL1 is occupied by connectors X6 and X7, these outputs correspond to parameters OP10-OP13. When working with the PLC, these outputs represent

PLC resources O1-O4.

• If slot SL1 is occupied with any of the I/O cards (16DI-8DO, 8DI-16DO), OV10 refers to PLC resources O1-O16.

When reading: Value of the digital outputs.

When writing: Values forced onto those digital outputs which do not have functions associated by parameters OP10-OP13.

0..65535 ($FFFF)

0 (unassigned)

We read that OV10 = 11 whose binary code is 1011. This means that outputs 1, 2 and 4 of connector X6 are active and output 3 is inactive. In other words, that contacts

(6,7), (8,9) and (12,13) are closed and contact (10,11) is open.

If we write that same data, we will be forcing the contacts to those positions, as long as OP10-OP13 are not associated.

Operative from version 02.01 on. Renewed in version 04.01

(F1413) DigitalOutputsCh2

The OV11 variable contains a binary coded numeric value which represents the status of the digital outputs present in slot SL2.

• At the PLC, the value of OV11 refers to resources O17-O32

When reading:

When writing:

0..65535 ($FFFF)

Value of the digital outputs.

Values forced upon the digital outputs.

0 (unassigned)

We read that OV11 = 35 whose binary code is 00100011. This means that resources

O17, O18 and O22 are active and the rest are inactive.

If we write this same data, we will be forcing the activation or deactivation of those resources.

Operative from version 04.01 on.

Drive Module (example)

SL2 SL1

1

X11

I17

I19

I21

I23

9

1

X12

I25

I27

I29

X13

I31

9

16DI-8DO

1

O17

O19

O21

O23

9

O18

O20

O22

O24

I26

I28

I30

I32

I18

I20

I22

I24

X8

1

I7

9

8DI-16DO

1

O1

I1

I3

I5

X9

O3

O5

O7

9

1

X10

9

I2

I4

I6

I8

O9

O11

O10

O12

O13

O14

O15

O16

O2

O4

O6

O8

Drive Module (example)

SL2 SL1

1 1

X8

I21

X9

I23

9

8DI-16DO

1

O17

O19

O21

O23

9

1

I17

I19

X10

O25

O27

O29

O31

9

O26

O28

O30

O32

O18

O20

O22

O24

I18

I20

I22

I24

X6

13

1

X7

11

P2

P1

A1

I1

I3

I2

I4

O1

O2

O3

O4

Parameters, Variables and Commands Ver. 0002 A - 33

14. GROUP FOR THE POSITIONING DRIVE “P”

This group will be operative from software version 04.01 on.

PP1.#

Function:

O

Valid values:

Default value:

PP10

Function:

Valid values:

Default value:

PP11

Function:

Valid values:

Default value:

PP12 s

Function:

Valid values:

Default value:

PP22

Function: s

Valid values:

Default value:

PP23

Function: s

(F1300.#) HomingVelocitySlow

It is the slow homing speed controlled by the Drive itself. This parameter is required when the homing operation is controlled by the drive: PC148 -S148-

DriveControlledHoming active.

motor rpm: 0 .. 214000

Motor rpm: 100

(F1310) ProcessBlockMode

In MC programs, it defines how the dynamic link is applied between positioning blocks that do not specify the parameter L (LINK).

0, NULL

2, WAIT_IN_POS

1,

3 ,

NEXT

PRESENT

0 (NULL, at zero speed)

(F1311) FeedrateOverrideLimit

It defines the maximum value the Feedrate override registered in the variable:

PV108 -S108- FeedrateOverride.

0 .. 250%

250%

(F1312) PositioningVelocityDefault

In MC programs, it defines the positioning feedrate applied to movement blocks that do not specify the parameter V (VELOCITY).

-214 .. 214 km/min

10 m/min

(F1322) JogVelocity

It is used as the value assigned to parameter V (VELOCITY) in the program

"manual.mc". Feedrate for all JOG movements.

-214 .. 214 km/min

5 m/min

Valid values:

Default value:

PP25

Function:

Valid values:

Default value:

PP41.# O

Function:

Valid values:

Default value:

(F1323) JogIncrementalPosition

Distance moved (step) in incremental jog with each up flank (leading edge) of the

JOG signals. It is used as the value assigned to parameter D (DISTANCE) in the incremental JOG movements programmed in the "manual.mc".

-214 .. 214 m

1 mm

(F1325) InPositionTime

Parameter related to the positioning blocks with L=WAIT_IN_POS. This link ends the movement at zero speed. It waits for the target position to be reached and for it to remain in that position a time period set by this parameter InPositionTime.

0 .. 65535 ms

10 ms

(S41.#) HomingVelocityFast

It is the fast homing feedrate when controlled by the Drive itself. This parameter is required when the homing operation is controlled by the Drive: PC148 -S148-

DriveControlledHoming active.

Motor rpm: 0 .. 214000

Motor rpm: 200

A - 34 Parameters, Variables and Commands Ver. 0002

PP42.#

Function:

O (S42.#) HomingAcceleration

It is the acceleration applied when the homing operation is controlled by the Drive itself. This parameter is required when the homing operation is controlled by the

Drive itself: PC148 -S148- DriveControlledHoming active.

0 .. 2140000 rd/sec 2

60 rd/sec 2

Valid values:

Default value:

PP49

PP50

Function:

Os (S49)

Os (S50)

Valid values:

Default value:

PositivePositionLimit

NegativePositionLimit

They indicate the maximum position (coordinate) that can be reached in the positive and negative direction respectively.

These limits are only considered when all the position data is referred to Machine

Reference Zero (home).

In other words, Bit 0 of PV203 -S403- PositionFeedbackStatus is "1".

If variable PV58 -S258 TargetPosition exceeds the position limits, the drive activates bit 13 of DV9 -S12- Class2Diagnostics (Warnings)

TargetPositionOutsideTheTravelZone.

-214 .. 214 m

214 m (-214 m)

PP52

Function:

Os (S52)

Valid values:

Default value:

ReferenceDistance1

When working with motor feedback, this parameter indicates the distance between

Machine Reference Zero point and home. It is similar to parameter "REFVALUE"

(P53) of the axes of the 8050/55 CNC.

-214 .. 214 m

0 m

PP54

Function:

Os (S54)

Valid values:

Default value:

ReferenceDistance2

When working with direct feedback, this parameter indicates the distance between

Machine Reference Zero point and home. It is similar to parameter "REFVALUE"

(P53) of the axes of the 8050/55 CNC.

-214 .. 214 m

0 m

PP55

Function:

O (S55) PositionPolarityParameters

16-bit register used to reverse the sign of the different position data. When in position loop, except for the position command, the signs are only changed on the monitored data and not internally. In the case of turning motors we will consider that if the sign of the position command is positive, they will turn clockwise. This parameter cannot be used to solve a positive feedback problem (motor runaway) due to the fact the second feedback is counting in the opposite direction. That problem is solved using parameter PP115 -S115- PositionFeedback2Type.

Bit Meaning

————————————————————————————-

15 (MSB), 14, 13, 12, 11, 10, 9, 8, 7, 6, 5 (reserved)

4,

3,

2,

1,

0, (LSB)

Position limits

= 0 active (by default). See PP49 and PP50.

= 1 cancels the position limits.

Direct position feedback value

= 0 non-inverted

= 1 inverted (by default)

Motor position feedback value

= 0 non-inverted

= 1 inverted (by default)

(reserved)

Position commandvalue

= 0 non-inverted

= 1 inverted (by default)

Parameters, Variables and Commands Ver. 0002 A - 35

PP57

Function:

O (S57) PositionWindow

It indicates the maximum difference allowed between the real position and the final position PV58 -S258- TargetPosition to consider that the drive is in position. Then, the Drive will activate parameter PV136 -S336- InPosition.

While executing the command.

0 .. 214 m

0.1 mm

Valid values:

Default value:

PP58

Function:

Os (S58)

Valid values:

Default value:

Backlash

Leadscrew backlash. It is only useful with motor feedback. It is used for the Position

Drive to compensate for that backlash when reversing the movement of the axis, thus making a load movement more similar to the position command. Both the Drive and the CNC offer parameters determining the value of the leadscrew backlash. This value must only be registered at one these units. The other parameter must be set to

"0".

-3.2 .. 3.2 m (in linear movements), -3.2 .. 3.2° (in rotary over 360°)

0

PP76

Function:

(S76) PositionDataScalingType

16-bit register configuring the position measurement scales. All of them must be "0" except bit 6 (1) and bit 7 which determines the activation or cancellation of the module format in the received commands

Bit Meaning

————————————————————————————-

15 (MSB), 14, 13, 12, 11, 10, 9, 8 (reserved)

= 0

7, Format

= 0 Absolute format (by default)

= 1 Module format. See PP103 and PP243.

Watch for the CNC to define this axis the same way (module or linear format).

= 1 (by default) 6,

5, 4, 3, 2, (reserved)

1, 0 (LSB) Scaling method

= 00 no scaling

= 01 linear scaling (by default)

= 10 rotational scaling manual.mc

#INCLUDE "C:\Fagor\MyFiles\MCFiles\fagor.inc"

; Modify the path if necessary

PROGRAM

PROG_OFFSET = 0

WHILE(1)

; Eliminate programmable position offset

; Endless loop

WAIT(!JOG_POS AND !JOG_NEG) ; Wait for Jog+ & Jog- to be zero

WAIT(JOG_POS OR JOG_NEG)

IF(JOG_POS AND !JOG_NEG)

; Wait for either one to be activated

; If Jog+ is activated but not Jog-

A - 36

ENDIF

ELSEIF(JOG_NEG AND !JOG_POS)

IF(K_MAN_SUBMODE)

; If Jog- is on but not Jog+

; If incremental Jog ...

MOVE D=-JOG_INC_POS V=JOG_VEL L=NULL

ENDIF

ENDWHILE

END

ENDIF

Parameters, Variables and Commands Ver. 0002

PP103 Os (S103)

Function:

Valid values:

Default value:

ModuloValue

Module value. If bit 7 of PP76 selects the "module format", this parameter defines the position data range it works with. The increment between consecutive position commands cannot be greater than half the value of PP103.

1 .. 214000°

360° (since it is usually used in rotary axes)

PP104.#

Function:

Valid values:

Examples:

Default value:

PP115 O

(S104.#) PositionKvGain

It sets the proportional constant value in the position loop "Kv". It is similar to parameter "PROGAIN" (P23) for the 8050/55 CNC axes. It is given in m/min of programmed velocity command per mm of following error.

0..32767 (m/min/mm)

S104=1 means that the following error for a programmed feedrate of 1000 mm/min

(F1000 at the CNC) will be 1 mm.

S104=2 at F1000 the following error will be 0.5 mm.

To obtain a following error of 5 microns at F2000, Kv will be: 2/0.005, that is:

S104=400

1 (1 mm of following error at a feedrate of F1000)

(S115) PositionFeedback2Type

Function:

PP147

Function:

It indicates various aspects of the Direct feedback X3:

Bit Meaning

————————————————————————————-

15 (MSB), 14, 13, 12, 11, 10, 9, 8 (reserved)

(reserved) 7, 6, 4, 2,

5,

3,

1,

0 (LSB)

Structure of distance coded feedback

= 0 counting positive with positive direction

= 1 counting negative with positive direction

Direction polarity

= 0 not inverted

= 1 inverted

Distance coded feedback

= 0 no distance coded reference marks

= 1 distance coded reference marks. See NP165, NP166.

Feedback type

= 0 rotational feedback. See NP117.

= 1 lineal. See NP118.

(S147) HomingParameter

16-bit register to determine the mechanical and electrical relationship between the homing process and the installation of the machine, the CNC or the Drive. When homing is controlled by the Drive, only bits 0, 1, 2, 3, 5, 6 and 7 are applicable.

When homing is controlled by the CNC, only bits 1, 2, 3 and 4 are applicable

Bit

6,

5,

Meaning

————————————————————————————-

15 (MSB), 14, 13, 12, 11, 10, 9, 8 (reserved)

7, Position after the procedure controlled by the Drive (reserved)

The reference mark I0 is ignored or not (reserved)

The home-switch is ignored or not

= 0 the home-switch is not ignored (by default)

4,

3,

2,

1,

= 1 the home-switch is ignored

To be interpreted at the drive (reserved)

Feedback being used

= 0 motor feedback (by default)

= 1 direct feedback

Home-switch connection (reserved)

0 (LSB)

Reference Mark position referred to that of the home-switch

= 0 first I0 after the up-flank of the home-switch

(by default)

= 1 First I0 after the down-flank of the home-switch

Movement direction

= 0 positive: the motor shaft turns clockwise

(by default)

= 1 negative: the motor shaft turns counterclockwise

Parameters, Variables and Commands Ver. 0002 A - 37

PP150 Os (S150)

Function:

Valid values:

Default value:

ReferenceOffset1

Parameter setting the position of the reference mark with respect machine reference point (home) according to the motor feedback. It is similar to parameter "REFSHIFT"

(P47) for the 8050/55 CNC axes, except that it does not move to return to the position of PP52 -S52- ReferenceDistance1, "REFVALUE" (P53) at the CNC.

-214 .. 214 m

0 m

PP151 Os (S151)

Function:

Valid values:

Default value:

ReferenceOffset2

Parameter setting the position of the reference mark with respect machine reference point (home) according to the direct feedback. It is similar to parameter "REFSHIFT"

(P47) for the 8050/55 CNC axes, except that it does not move to return to the position of PP52 -S52- ReferenceDistance1, "REFVALUE" (P53) at the CNC.

-214 .. 214 m

0 m

PP159

Function:

O

Function:

Valid values:

Default value:

PP216.#

Function:

(S177) MonitoringWindow

It sets the maximum range for the following error. When the following error exceeds the value given by PP159, the drive issues error 205 ExcessivePositionDeviation

(DV1 -S11-, Bit 11). If this parameter is set to "0", the following error is not monitored.

It is very important to give it a value other than "0" to prevent the axes from running away out of control. At the CNC, this maximum following error range is monitored by setting its relevant parameters for each axis.

0 .. 214 m (0 = the following error is not monitored)

30 mm

Valid values:

Default value:

PP177

Function:

O

Valid values:

Default value:

PP178 O

Valid values:

Default value:

(S177) AbsoluteDistance1

For motors with absolute encoder. It indicates the distance between the zero position for the drive and the theoretical zero according to the absolute feedback of the encoder.

214 .. 214 m

0 m

(S178) AbsoluteDistance2

For absolute direct feedback. It indicates the distance between the zero position for the drive and the theoretical zero according to the absolute feedback of the encoder.

214 .. 214 m

0 m

(S296.#) VelocityFeedForwardPercentage

It sets the percentage of velocity Feedforward to be applied. It is similar to "FFGAIN"

(P25) for the axes of the 8050/55 CNC. It indicates the % of velocity command anticipated to the movement independent from the following error (open loop).

0 .. 120%

0% (Feedforward is not applied)

PP217.#

Function:

Valid values:

Default value:

(S348.#) AccelerationFeedForwardPercentage

(Not available yet)

It sets the percentage of acceleration Feedforward to be applied.

0 .. 120%

0% (Feedforward is not applied)

A - 38 Parameters, Variables and Commands Ver. 0002

PP243.# O (S393.#)

Function:

Valid values:

Default value:

ModuloComandMode

When the Modulo function is active, the interpretation of position commands is dependent upon the Modulo command mode setting.

Bit Meaning

————————————————————————————-

15 (MSB) - 2 (reserved)

0 .. 2

2

1, 0 (LSB) = 00 clockwise

= 01 Counterclockwise

= 10 shortest path (by default)

= 11 reserved

PV13 W

Function:

Valid values:

PV14 W

Function:

Valid values:

(F1313)

It indicates which is the main operation mode.

0, Automatic mode (by default after drive power-up)

1, Manual mode

(F1314)

KernelOperationMode

KernelAutoMode

It indicates which is the operation submode within the automatic mode (PV13 = 0).

0, Continuous submode

1, Single Block submode

2, Single instruction submode

PV15

Function:

W

PV16

Function:

PV17

Function:

W

W

(F1315) KernelStartSignal

Digital signal which sets (with its up flank 0-to-1 transition), the start of the MC program execution in automatic or manual mode. After powering the system up, the execution must ALWAYS be started through this "Start" signal as well as after any of the Stop, Reset and Abort signals has been activated. An up flank of this signal must also be generated to resume execution while in "Single Block" or "Single instruction" mode.

(F1316) KernelStopSignal

Digital signal which sets, (with its up flank 0-to-1 transition) the momentary interruption of the movement block and stops the motor. This signal does not finish the block, it only interrupts it so when the "Start" signal

PV15 -F1315- KernelStartSignal is activated, it goes on to execute the remaining portion of the block.

(F1317) KernelResetSignal

Digital signal which resets (with its up flank 0-to-1 transition) the execution of the MC program. This signal interrupts the execution, restores the initial values and the drive remains waiting for a new "Start" signal PV15 -F1315- KernelStartSignal.

PV18

Function:

W

PV19

Function:

Valid values:

PV20

Function:

W

W

(F1318) KernelAbortSignal

Digital signal which sets (with its up flank 0-to-1 transition) the final interruption of the movement block and stops the motor. This signal ends the block and the drive remains waiting for a new "Start" signal PV15 -F1315- KernelStartSignal.

(F1319) KernelManMode

It indicates which is the operation submode within the manual mode (PV13 = 1).

0, Continuous submode (by default)

1, Incremental submode

(F1320) JogPositiveSignal

Digital signal used in the "manual.mc" program to activate the JOG movement in the positive direction.

Parameters, Variables and Commands Ver. 0002 A - 39

PV21

Function:

W

PV24

Function:

PV26

(F1324) FeedrateOverrideEqualCero

Digital signal which indicates that the value of the FeedrateOverride at the machine is zero and, therefore, the motor cannot be moved in any way.

Ws (F1326) ProgramPositionOffset

Function: With this variable it is possible to set an offset with respect to the machine reference point (home) and it may be applied to the absolute positioning blocks in the MC program. The ZERO statement updates this variable.

-214 .. 214 m (0 m by default) Valid values:

PV27

Function:

Valid values:

(F1327) KernelInitError

Index indicating the exact meaning of error 900.

Error 900 comes up on the Drive's status display when initializing the MC program. It cancels the system initialization process and prevents the MC software from running.

0 If no error comes up when initializing.

1 AUTOMATIC application not loaded into memory

2 MANUAL application not loaded into memory

3 Wrong AUTOMATIC application file

4 Wrong MANUAL application file

5 AUTOMATIC application file too large (8Kbytes max.)

6 MANUAL application file too large (512 bytes máx.)

7 Wrong drive variable in AUTOMATIC application

8 Wrong drive variable in MANUAL application

9 Too many drive variables in AUTOMATIC application

10 Too many drive variables in MANUAL application

11 Code checksum error

12 Internal error when initializing the drive table

13 Internal error when initializing variable indexes

14 Error when initializing the application

15 PLC resources not accessible in AUTOMATIC application

16 PLC resources not accessible in MANUAL application

17 Too many PLC MARKS in AUTOMATIC application

18 Too many PLC MARKS in MANUAL application

19 Too many PLC REGISTERS in AUTOMATIC application

20 Too many PLC REGISTERS in MANUAL application

21 Too many PLC COUNTERS in AUTOMATIC application

22 Too many PLC COUNTERS in MANUAL application

PV28

Function:

Valid values:

(F1321) JogNegativeSignal

Digital signal used in the "manual.mc" program to activate the JOG movement in the negative direction.

(F1328) KernelExecError

Variable that groups the execution errors of the MC program (901-915)

This errors are communicated via the Drive Status Display. They interrupt the execution of the program and prevent the MC software from running making it possible to consult the values of the variables and parameters.

0 If no error has come up.

1 Division by zero (error 901 at the Status display)

2 Array size exceeded (error 902, etc.)

3 Call nesting limit exceeded

4 Error when writing a variable

5 Internal error when reading a variable

6 Internal error when writing a variable

7 Overflow when evaluating a statement

8 Stack overflow

9 Stack Underflow

10 Overflow when calculating position

11 Absolute positioning without homing

12 Attempt of writing a PLC counter

13 Unknown Pcode

14 TargetPosition exceeds ModuloValue

15 The position increment is greater than half the ModuloValue

A - 40 Parameters, Variables and Commands Ver. 0002

PV47

PV51

PV53

Function:

Ws (S47) s (S51) s (S53)

Valid values:

PositionCommand

PositionFeedback1

PositionFeedback2

Position command value. Position command value through motor feedback. Position command value through direct feedback. They are transferred from the drive to the control unit.

-214 .. 214 m

PV58

Function:

Ws (S258)

Valid values:

TargetPosition

Target position for the current positioning block. The system attends to the target position indicated in the MC instruction and not to the one indicated in this parameter

-214 .. 214 m

PV59

Function:

Ws (S259)

Valid values:

PositioningVelocity

Positioning velocity for the current positioning block (in module). The system attends to the positioning velocity indicated in the MC instruction and not to the one indicated in this parameter.

0 .. 214 m/min

PV60

Function:

Valid values:

PV108

Ws (S260)

W (S108)

PositioningAcceleration

Acceleration applied to all the positioning blocks.

0 .. 200 m/s 2

FeedrateOverride

Function:

Valid values:

Override applied to the positioning feedrate in all the programmed movements.

The value that this variable can take is limited by parameter

PP11 -F1311- FeedrateOverrideLimit.

It would vary between 0% and the value indicated by

PP11 -F1311- FeedrateOverrideLimit.

PV115

Function:

Valid values:

(S315) PositioningVelocityGreaterLimit

It is a mark that is activated when the positioning feedrate exceeds the limit set by

SP10 -S91- VelocityLimit.

0, 1 (0 by default)

PV123

Function:

Valid values:

PV136

Function:

Valid values:

PV142

Function:

Valid values:

PV143

Function:

Valid values:

(S323) TargetPositionOutsideOfTravelRange

It is a mark that is activated wen the target position programmed for the current positioning block is out of the position limits set by parameters

PP49 -S49- PositivePositionLimit, or PP50 -S50- NegativePositionLimit.

0, 1 (0 by default)

(S336) InPosition

It is a mark that is activated when the target position has been reached

PV58 -S258- TargetPosition. In this positioning, there is a tolerance margin (dead band) set by parameter PP57 -S57- PositionWindow

0, 1 (0 by default)

(S342) TargetPositionAttained

It is a mark that indicates that the interpolator has reached the target position. It is activated when the position command PV47 -S47- PositionCommand is equal to

PV58 -S258- TargetPosition

0, 1 (0 by default)

(S343) InterpolatorHalted

It is a mark that indicates that the interpolation has been interrupted (the position command does not change) but the current positioning block is not completed.

0, 1 (0 by default)

Parameters, Variables and Commands Ver. 0002 A - 41

PV173

Function:

Valid values:

PV175 O

Function:

Valid values:

PV176 O

Function:

Valid values:

PV189 s

Function:

Units: s (S173) MarkerPositionA

In the homing process, when the drive detects the reference mark (I0), it stores the instantaneous value of the position feedback (PositionFeedback not yet homed) in this variable MarkerPositionA.

-214 .. 214 m (0 by default)

(S175) DisplacementParameter1

It indicates the shift in the coordinate system after the drive has homed the axes

(when working with motor feedback).

-214 .. 214 m (0 by default)

(S176) DisplacementParameter2

It indicates the shift in the coordinate system after the drive has homed the axes

(when working with direct feedback).

-214 .. 214 m (0 by default)

(S189) FollowingError

It registers the difference between the position command and the position feedback.

PV189 = PV47 - PV51/53

FollowingError = PositionCommand – PositionFeedback1/2 tenths of a micron in linear movements and ten-thousandths of a degree in rotary movements.

PV193 Os (S193)

Function:

Valid values:

PositioningJerk

Jerk limit for the current positioning block (in module).

0 .. 1000 m/s 3

PV200

Function:

O (S400) HomeSwitch

Example:

Valid values:

PV203

Function:

This binary parameter represents the logic state of the Home-switch. To do this, this variable must be associated with one of the digital inputs of the drive connected to the switch.

If no PLC is used, assign the PV200 variable to parameter IP10 (pins 1 and 5 of X6).

If a PLC is used, the instruction may be: I1 = B0S400.

0, switch off

1, switch on (the axis is positioned on the switch)

(S403) PositionFeedbackStatus

Valid values:

The drive activates this binary parameter to inform that the feedback position is to be considered as referred to Machine Reference Zero.

The parameter is deactivated when the following command is executed:

PC148 -S148- DriveControlledHoming and it is reactivated when it is carried out successfully.

or when the drive loses its reference to Machine Reference Zero.

0, position data referred to Machine Reference Zero.

1, position data referred to any point.

PV204 W (S404)

Function:

PositionCommandStatus

Parameter for internal system use. It indicates whether the position command is referred to machine reference zero or not.

PV207

Function:

Valid values:

(S407) HomingEnable

Homing enable

The drive takes this function into account only if the homing process is controlled by the CNC. In other words, through the command: PC146 -S146- NCControledHoming.

0, homing disabled

1, homing enabled

A - 42 Parameters, Variables and Commands Ver. 0002

PV208

Function:

Valid values:

PC146

Function:

Valid values:

(S408)

(S146)

ReferenceMarkerPulseRegistered

This binary parameter is activated when the drive detects the reference mark when homing. At that instant, the drive stores the PositionFeedback in the MarkerPositionA

0, 1

NCControlledHoming

Command to activate the homing process controlled by the CNC. When the reference mark is detected in the homing process, the drive stores the PositionFeedback in the

MarkerPositionA. Later on, the drive activates the ReferenceMarkerPulseRegistered mark.

0, 3

PC148

Function:

Valid values:

PC171

PC172

Function:

(S148) DriveControlledHoming

Command to activate the homing process controlled by the drive. The

PV203 -S403- PositionFeedbackStatus is deactivated.

This process is configured with the following parameters:

PP147 -S147- HomingParameter

PP41 -S41- HomingVelocityFast

PP42 -S42- HomingAcceleration

PP1 -F1300- HomingVelocitySlow

And the variables involved in its execution are:

PV200 -S400- HomeSwitch

PV173 -S173- MarkerPositionA

PV208 -S408- ReferenceMarkerPulseRegistered

The process ends when the motor stops and the position feedback value is referred to machine reference zero. The drive adjusts the position command so it matches the new feedback position. Then, the drive activates parameter

PV203 -S403- PositionFeedbackStatus.

0, 3

(S171)

(S172)

CalculateDisplacement_C

DisplacementToTheReferenceSystem

Commands for internal system use.

PV47

-S47PP55

-S55bit 0

PV51

-S51-

PP55

-S55bit 2 bit 3

PV53

-S53-

SV1

-S36-

SP43

-S43bit 0

TV1

-S80-

TP85

-S85bit 0

Position loop

SP43

-S43bit 2

SV2

-S40-

Velocity loop

TP85

-S85bit 2

TV2

-S84-

Current loop

Parameters, Variables and Commands Ver. 0002 A - 43

15. SERCOS COMMUNICATION GROUP “Q”

QP1

Function:

Valid values:

QP11

Function:

Valid values:

(S1) ControlUnitCycleTime

Read-only parameter that indicates the loop closing period at the drive.

32 .. 1 ms ( every 4 ms by default)

(F2000) SercosMbaud

It sets the data transmission speed (baudrate) through the Sercos ring. The CNC has a similar parameter. In order to be able to establish communication, they both have to be set to the same baudrate.

1, 2 Megabaud (by default)

0, 4 Megabaud

Rotor Sensor

H V2-X 3 B oa rd Id

R P 3 -F 1 5 0 2 R P 1 -F 1 5 0 0 -

Feedback

SineOffset

Feedback

SineGain

X4 (DDS)

From Motor

Sensor

G P 2 -F7 0 1 -

1: Resolver

G P 2 =0

G P 2 =1

G P 2 =2

Sensor

Evaluation

R P 4 -F1 5 0 3 R P 2 -F 1 5 0 1 -

Feedback

CosineOffset

Feedback

CosineGain

R V 1 -F1 5 0 6 -

R V 2 -F1 5 0 7 -

Sensor

Position

R P 5 -F1 5 0 4 FeedbackResolver

RhoCorrection

Position

Speed

Encoder

R V 3 -F1 5 0 8 Feedback

RhoCorrection

S V 2 -S 4 0 -

VelocityFeedback

To Speed Loop

A - 44 Parameters, Variables and Commands Ver. 0002

16. ROTOR SENSOR GROUP “R”

RP1

RP2

RP3

RP4

O

O

Function:

Valid values:

(F1500)

(F1501)

FeedbackSineGain

FeedbackCosineGain

Compensation (proportional gain mode) of the sine/cosine signal that reaches the drive from the motor feedback.

1500..3070 (2032 by default)

Os (F1502)

Os (F1503)

FeedbackSineOffset

FeedbackCosineOffset

Function:

Valid values:

RP5

Function:

O

Valid values:

RP6.# O

Function:

Valid values:

Compensation (offset mode ) of the sine/cosine signal that reaches the drive from the motor feedback.

-1000..1000 (0 by default)

(F1504) FeedbackResolverRhoCorrection

Corrects the phase shift between the magnetic shaft of the resolver and the rotor of the motor. The motors are factory set and, normally, it should not be necessary to touch RP5 .

0..65535 (0 by default)

(F1505.#) FeedbackErrorDisable

It allows inhibiting the communication of possible feedback errors ( 5xx group).

0, Normal operation. If there is a malfunction, an error message is issued (by default).

1, Feedback errors are ignored.

RP10

Function:

O

Valid values:

RP51

RP52

Function:

O

O

Valid values:

(F1514) Feedback2Interface

Type of electrical signal provided by the direct feedback.

0, no feedback

1, squarewave (by default)

2, Sinewave 1 Vpp

(F1550)

(F1551)

Feedback2SineGain

Feedback2CosineGain

Compensation (proportional gain mode) of the sine/cosine signal that reaches the drive from the direct feedback.

1500..2032 (2032 by default)

RP53

RP54

Function:

Os (F1552)

Os (F1553)

Valid values:

Feedback2SineOffset

Feedback2CosineOffset

Compensation (offset mode ) of the sine/cosine signal that reaches the drive from the direct feedback.

-1000..1000 (0 by default)

RV1

RV2

Function: s s

(F1506)

(F1507)

FeedbackSine

FeedbackCosine

Sine and Cosine of the feedback reaching the drive from the motor as internal system variables.

-32768..32767

Valid values:

RV3 F

Function:

Valid values:

(F1508) FeedbackRhoCorrection

Corrects the phase shift between the shaft of the encoder and that of the rotor of the motor. The motors are factory set and the value of this variable is stored in the encoder memory. Executing the EC1 command acts upon this value stored in the encoder.

0..65535

Parameters, Variables and Commands Ver. 0002 A - 45

RV4

Valid values:

Version:

RV5

Function:

RV6

Function:

RV7

Function:

Valid values:

Version:

RV8

Function:

F

Valid values:

Version:

RV51

RV52

Function: s s

Valid values:

Version:

RV54

Valid values:

Version:

(F1509) FeedbackRadius

0 .. 32767

Available from version 02.01 on.

(F1515) EncoderType

The RV5 variable contains a 16-bit numeric value. The least significant bits indicate the type of Encoder installed on the motor according to the following table:

Bits Values Meaning

————————————————————————————-

7-0 02h Sincos Encoder

12h SincoderEncoder

15-8 Reserved

(F1510) EncoderError

The RV6 variable contains a list of feedback errors for the exclusive use of Fagor technicians.

(F1511) StegmannMotorType

The motor encoder stores in its memory the motor id reference. This variable RV7 reflects in the drive memory the reference stored in the encoder. See sales references in appendix "C".

RV7 will keep this value as long as the motor is not changed.

The sales references of the motors listed in appendix "C".

Operative from version 03.03 on.

(F1512) CircleAdjust

Variable for activating the "Circle Adjustment". This adjustment consists in setting parameters RP1, RP2, RP3 and RP4 to the right values to make the motor run more quietly. It is called "Circle adjustment" because it refers to the Sine and Cosine signals handled by software (RV1, RV2) so they are mathematically correct. In other words, they represent a perfect circle.

This process is only applicable to an Encoder, not a Resolver. See chapter SU.

1 Adjustment in progress.

0 Adjustment completed.

Operative from version 03.03 on.

(F1556)

(F1557)

Feedback2Sine

Feedback2Cosine

Sine and Cosine of the feedback signal reaching the drive from the direct feedback as internal system variables.

-32768..32767

Operative from version 04.01 on

(F1559) Feedback2Radius

0..32767

Operative from version 04.01 on.

A - 46 Parameters, Variables and Commands Ver. 0002

RC1

Function:

O

Uses:

Version:

(F1509) EncoderParameterStoreCommand

It has several functions:

- For Sincos, it formats the encoder memory like the Sincoder. In the latter, the formatting is fixed.

- It records the offset of the encoder.

- It records the registration number of the motor.

- It records the registration version (this is for internal use only).

- Software upgrades.

When programming a 3.1 version onto a 2.X version. Use this command to record the registration number on the encoder.

- Recording the encoder offset.

Be it a brand new encoder or a used one, this command is good for either one. Be sure that MP1 has the right registration number when executing this command.

It works all the same with Sincos as with Sincoder.

Available from version 03.01 on.

Parameters, Variables and Commands Ver. 0002 A - 47

17. SPEED GROUP “S”.

SP1.#

SP2.#

*

*

Function :

Valid values:

(S100.#)

(S101.#)

VelocityProportionalGain

VelocityIntegralTime

Value of the proportional/integral action of the speed PI.

SP1: 0..16384 RMS milliAmperes / rpm.

SP2: millisecond

(S211.#)

(S212.#)

VelocityAdaptationProportionalGain

VelocityAdaptationIntegralTime

SP4.#

SP5.#

Function:

*

*

Units:

Valid values:

Default value:

SP6.# O

Function:

Valid values:

Default value:

SP7.# O

Adapting the proportional / integral of the PI at low speeds.

SP4 is the multiplying factor applied to SP1 when the motor moves at low speed. SP5 is the multiplying factor applied to SP2 at low speeds.

Deci% (thousandths)

25 .. 400% In other words, the PI action at low speeds can go from 25% to 400% of that at high speeds.

SP4*SP1 / 1000 must be smaller than the maximum value of SP1.

SP5*SP2 / 1000 must be smaller than the maximum value of SP2.

100% (constant proportional / integral action at any speed)

(S209.#) VelocityAdaptationLowerLimit

Is the upper limit of the speeds considered "low".

Must be smaller than: SP7 (VelocityLoopUpperAdaptationLimit) rpm.

10% of SP10 (VelocityLimit) rpm.

Function:

Valid values:

Default value:

(S210.#) VelocityAdaptationUpperLimit

Is the lower limit of the speeds considered "high".

Must be: smaller than SP10 (VelocityLimit) greater than SP6 (VelocityLoopLowerAdaptationLimit)rpm.

80% of SP10 (VelocityLimit) rpm.

rpm.

SP10.#

Function:

O (S91.#)

Valid values :

Default value:

SP11 FMA (S113)

VelocityLimit

Maximum value to be assumed by SV7 (VelocityLoopUpperAdaptationLimit).

If SV2 (VelocityFeedback) is 12% greater than this parameter, error 200 is generated

"overspeed"

0..10000 (depends on the motor connected) rpm.

110% of SP12 (NominalMotorSpeed); SP11 (MaximumMotorSpeed) rpm.

MotorMaximumSpeed

Function:

Valid values:

Maximum speed attainable by an asynchronous motor

Smaller than SP10 (otherwise, it issues 500-3-)

Adapter-Speed-PI:

S P 4 *S P 1

S P 2

S P 5 *S P 2

S P 1

Example:

T i

K p

S P 6 S P 7

Speed

160

130

65

80

1000

SP1 = 80 SP2 = 1300

SP4 = 2000 SP5 = 500

SP6 = 1000 SP7 = 3000

Kp

Ti

3000 Speed

A - 48 Parameters, Variables and Commands Ver. 0002

SP12 FM (F1600)

Function:

Valid values:

MotorRatedSpeed

Synchronous: Rated Speed

Asynchronous: Base Speed. The constant power area is beyond this base speed

Synchronous: Must be greater than SP10. otherwise, it issues 500 DV15=3

Asynchronous: Must be smaller than SP11.

SP20.#

Function:

Valid values:

Default value:

SP21.#

Function:

Valid values:

Default value:

SP30

SP31

Function:

Valid values:

Default value:

SP40.#

Function:

*s

*s

O

(F31.#) VoltageRpmVolt

Parameters Voltage_rpm/Volt (SP20) and rpm_rpm/Volt (SP21), define the ratio between the analog voltage and the motor speed. Corresponds to the CNC feedrate concept of G00 Feed.

1000..10000 Millivolts

9500 Millivolts

(F81.#) RpmRpmVolt

See SP20.

10..10000 (depends on the motor connected) rpm.

SP11 (MaximumMotorSpeed) rpm.

SP12 (RatedMotorSpeed) rpm.

(F1603)

(F1604)

AnalogInputOffset1

AnalogInputOffset2

Compensation of the offset of analog inputs 1 and 2 respectively.

-10000..10000 mV

0 mV

(S125.#) VelocityThresholdNx

Valid values:

Default value:

SP41.# O

Function:

Valid values:

Default value:

Speed value below which logic mark “n feedback

< n x

” is activated. The logic mark is the

SV3 variable. It can be used to know when the speed exceeds a particular value. This nomenclature n x

corresponds to the one defined by Sercos. In the machine-tool industry it is referred to as n min

Example of how to use it:

.

If in a particular application, we would like to know when the motor exceeds 400 rpm.

We will set this parameter, SP40, with a value of 400. When the motor exceeds this speed, its associated mark SV3 will be activated.

0..SP12 (depends on the motor connected) rpm.

20 rpm.

(S157.#) VelocityWindow

Speed window assigned to logic mark “n feedback

= n command

”.

The logic mark is variable SV4. This mark is used to find out when the actual motor speed

(n feedback

) has reached the command value (n

SP41 command

) within the boundaries of this window

0..12% of parameter SP10 (VelocityLimit)

20 rpm.

SP10, SP20, SP21: mV

10000

500

SP20

RATI

O SP20

SP21

/SP2

1

0

1000 2000 3000 4000

SP10

SP10 x 1.12

rpm

Parameters, Variables and Commands Ver. 0002 A - 49

SP42

Function:

Valid values:

Default value:

SP43

Función:

O

Version:

O (S124) StandStillWindow

Margin of low speeds that will activate logic mark “n feedbackl

The logic mark is variable SV5.

< n min

”.

This nomenclature, n min

, corresponds to the one defined by SERCOS. In the machine-tool world, it is called n=0.

Example:

If in a particular application, we would like to know when the motor is stopped within a 10 rpm margin, we would set this parameter SP42 with a value of 10 and when the motor stops, its associated mark SV5 will be activated.

0..SP12

(NominalMotorSpeed) rpm.

20 rpm.

(S43) VelocityPolarityParameter

This parameter is used to switch polarities of velocity data for specific applications.

When in velocity loop, except for the velocity command, the sign is changed only on the monitored data, but not internally. The motor shaft turns clockwise when there is a positive velocity command difference and no inversion is programmed. This parameter cannot be used to solve the positive feedback problem originated because the 2nd feedback counts in the opposite direction (motor run away). This case is only solved using parameter PP115 -S115- PositionFeedback2Type.

Operative from version 04.01 on.

SP60.# O

SP62.# O

SP64.# O

Function:

(S138.#)

(F1606.#)

(F1608.#)

Bit Meaning

————————————————————————————-

15 (MSB) - 3 (reserved)

2,

1,

0 (LSB)

Velocity feedback value

= 0 non-inverted

= 1 inverted

(reserved)

Velocity command value

= 0 non-inverted

= 1 inverted

AccelerationLimit

AccelerationLimit2

AccelerationLimit3

Acceleration limit 1, 2, 3. They define, together with SP61 and SP63, the ramps for filtering the velocity command SV8.

In order for them to be effective, SP80 must be "0".

SP60 is also useful in the Jerk limitation mode.

rad/s 2 . The conversion is 1 rad/sec 2 = 9.5492 rpm/s = 0.009549 rpm/ms

0..2

16 (by default, 1000)

(F1605.#)

(F1607.#)

AccelerationLimitVelocity2

AccelerationLimitVelocity3

Units:

Valid values:

SP61.# O

SP63.# O

Function:

Valid values:

Default value:

SP65.# O

Function:

Units:

Valid values:

Velocity limit up to which acceleration 1, 2 is applied. They define, together with SP60,

SP61 and SP62, the ramps for filtering the velocity command SV8.

In order for them to be effective, SP80 must be "0".

0..10000 rpm.

1000 rpm.

(F1609.#) EmergencyAcceleration

In an emergency stop, it limits the velocity command acceleration to stop the motor.

When set to "0", its limiting effect is canceled. SP70 must be set to "1" in order for the

SP65 limitation to be applied during an emergency stop.

rad/s 2 . The conversion is 1 rad/sec 2 = 9.5492 rpm/s = 0.009549 rpm/ms

0..2

16 (by default, 1000)

SP70 O

Function:

Valid values:

Default values:

(F1610) AccelerationOnEmergency

Determines whether or not in an emergency stop caused by Speed_Enable, Halt function, or Stop due to Error, the acceleration limit set by SP65 is applied or not.

0,1 (No ramps applied / Yes)

0 (No ramps applied)

A - 50 Parameters, Variables and Commands Ver. 0002

SP80.#

Function:

O

Units:

Valid values:

SP100.# O

(S349.#) JerkLimit

Limits the "jerk" of the velocity command. In other words, how fast the acceleration varies. It acts together with the acceleration limit SP60.

To cancel the effect of this limitation, parameter SP80 must be set to "0".

rad/s 3 . The conversion is 1 rad/sec 3 = 9.5492 rpm/s 2

0..2

16 (by default, 1000)

(F1611.#) AccelerationLimitOn

Function:

Valid values:

Default value:

Activates or deactivates the set of command limits and filters (ramps, Jerk). It does not affect the acceleration limitation in an Emergency.

0 / 1 (Off / On)

0 (limits off)

SV1

SV2

Function:

Ws (S36) s (S40)

Units:

VelocityCommand

VelocityFeedback

Display of velocity command /feedback values. They are transferred from the drive to the control unit.

rpm.

SP40, SV3 :

1

0

SV2 nfeedback

SP40 (nx)

Time nfeedback<nx

Time

SP41, SV4 : SP42, SV5 :

1

0

SP41 ncommand

SV2 nfeedback

Time nfeedback=ncommand

Time

SP42

1

0

SV2 nfeedback

0rpm

Time nfeedback<nmin

Time

SV1

-S36-

SP43

-S43bit 0

SP43

-S43bit 2

SV2

-S40-

Parameters, Variables and Commands Ver. 0002

TV1

-S80-

TP85

-S85bit 0

Velocity loop

TP85

-S85bit 2

TV2

-S84-

Current loop

A - 51

SV3

Function:

Valid values:

SV4

Function:

Valid values:

SV5

Function:

Valid values:

SV7

Function:

Units: s

SV8

Function:

Units: s

(S332) nFeedbackMinorNx

Logic mark associated to: n feedback

0 / 1, no / yes

< n x

See parameter SP40.

(S330) nFeedbackEqualNCommand

Logic mark associated to: n feedback

0 / 1, no / yes

= n command

See SP41.

(S331) nFeedbackEqual0

Logic mark associated to: n feedback

0 / 1, no / yes

< n min

See parameter SP42.

(F1612) VelocityCommandFinal

It returns the velocity command value before limitations, ramps, etc.

rpm.

(F1613) VelocityCommandBeforeFilters

It gives the value of the velocity command before the limitations, ramps, etc.

rpm.

Halt Function

SpeedEnable Function

Error Stop

O R

O R

Ramps

S P 6 0 ...

...S P 6 4

S P 8 0 = 0

Jerk

S P 6 0

S P 8 0

S P 8 0 < > 0

ErrorStop OR

SpeedEnable Function

means

PWM_OFF if the motor has not stopped in a time period GP3

S P 1 0 0 = 1

S P 1 0

S V 7

S P 1 0 0 = 0

S V 8

Acc. Emerg.

S P 6 5

S P 7 0 = 1

S P 7 0 = 0

Ramps: Jerk: Emergency:

S P 6 3

S P 6 4

S P 6 2

S P 6 1

S P 6 0

Time

SP100=1 SP80=0

S P 6 0

SP100=1 SP80<>0

Time

SP70=1

S P 6 5

Time

A - 52 Parameters, Variables and Commands Ver. 0002

18. TORQUE AND POWER GROUP "T".

TP1 Os (S126)

Function:

Units:

Valid values:

Default value:

TorqueThresholdTx

Torque threshold set by the used to activate logic mark TV10.

Fraction of the rated motor torque.

0..100% (it depends on the Driver connected)

5%

TP2

Function:

Os (S158)

Units:

Valid values:

Default value:

PowerThresholdPx

Power threshold set by the user to activate logic mark TV60.

This value is given as a fraction of the motor power.

The power of the motor is:

On a synchronous FXM motor = the product of three elements:

MP2 -F1200- MotorTorqueConstant

MP3 -S111- MotorContinuousStallCurrent

SP12 -F1600- MotorRatedSpeed

On an asynchronous SPM motor =

MP12 -F1208- MotorNominalPower

Fraction of the rated (nominal) motor power.

1..100%

5%

TP85

Función:

O

Version:

TV1

TV2

Function: s s

(S85) TorquePolarityParameter

This parameter is used to switch polarities of reported torque data for specific applications. Polarities are not switched internally but externally (on the input and output) of a closed loop system. The motor shaft turns clockwise when there is a positive torque command difference and no inversion is programmed. This parameter cannot be used to solve the positive feedback problem originated because the 2nd feedback counts in the opposite direction (motor run away). This case is only solved using parameter PP115 -S115- PositionFeedback2Type.

Operative from version 04.01 on.

Bit Meaning

————————————————————————————-

15 (MSB) - 3 (reserved)

2,

1,

0 (LSB)

Torque feedback value

= 0 non-inverted

= 1 inverted

(reserved)

Torque command value

= 0 non-inverted

= 1 inverted

(S80)

(S84)

TorqueCommand

TorqueFeedback

Display of the torque command/feedback value. They are transferred from the drive to the control unit.

-1000..1000 Nm.

Valid values:

TV3 s

Function:

Valid values:

Version:

(F1701) TorqueFeedbackPercentage

Instantaneous display of the percentage of power used with respect to the maximum available at that velocity and servo drive system (Motor, Drive, current limit)

0..1000 º/oo

Operational from version 02.03 on

TV10

Function:

Valid values:

(S333) TGreaterTx

Logic mark to indicate that the Torque (TV2) is greater than the TorqueThresholdTx

(TP1). See TP1.

0, TV2 < TP1

1, TV2 > TP1

Parameters, Variables and Commands Ver. 0002 A - 53

TV50 s

Function:

Valid values:

TV60

Function:

Valid values:

TV100

Function:

Valid values:

(F1700) PowerFeedback

Display of the power feedback value.

-100..100 KiloWatts.

(S337) PGreaterPx

Logic mark to indicate that the Power (TV50) is greater than the PowerThresholdPx

(TP2). See TP2.

0, TV50 < TP2

1, TV50 > TP2

(F1702) TorqueStatus

Indicates whether there is torque or not.

Caution: there is also torque when braking.

The error causing it to brake does not disable the torque.

0, There is no torque

1, There is torque

A - 54 Parameters, Variables and Commands Ver. 0002

19. INTERNAL GENERATOR GROUP “W”

WV1 W

Function:

Valid values:

(F1800) GeneratorShape

It indicates the waveform of the internal command generator.

0- Sinusoidal

1- Square

2- Triangular

3- Continuous

WV2 W

Function:

Valid values:

(F1801) GeneratorPeriod

It indicates the period of the signal from the internal command generator.

2..65535 msec.

WV3 Ws (F1802)

Function:

Valid values:

GeneratorAmplitude

It indicates the amplitude of the signal from the internal command generator.

0..32767 rpm if it is a velocity command microns if it is a position command for a linear axis.

tenths of a degree if it is a position command for a rotary axis.

WV4 O

Function:

Valid values:

(F1803) GeneratorType

It establishes upon which magnitude the internal velocity command is applied.

0-Generator off (by default)

1-Generator on. Speed Command.

2-Generator on. Torque Command.

Inoperative from version 04.01 on.

Version:

WV5 s

Function:

Valid values:

Version:

WV6

Function:

W

Valid values:

Version:

WV7 W

(F1804) GeneratorOutput

Is the value of the signal generated by the internal function generator.

-32768 .. 32767 given in the units indicated for WV3.

Operative from version 04.01 on.

(F1805) GeneratorDutyCycle

For generating square signals (WV1=1), this variable gives the percentage of duty cycle. For example a cycle of S6-40%, WV6=40.

1 .. 99 (50 by default)

Operative from version 04.01 on.

Function:

Valid values:

Version:

(F1806) GeneratorWaves

Number of waves generated after the unit has been turned on. Then, the generator stops. By making WV7=0 the generator works continuously.

0 .. 65535 (0 by default)

Operative from version 04.01 on.

WV8 W

Function:

Valid values:

(F1807) GeneratorOn

To turn the generator on or off.

0, Generator off. (by default)

1, Generator on.

Operative from version 04.01 on.

Version:

WV9 Ws (F1808) GeneratorOffset

Function:

Valid values:

Version:

It makes it possible to apply an offset to the signal of the internal command generator.

-32768 .. 32767

Operative from version 04.01 on.

Parameters, Variables and Commands Ver. 0002 A - 55

20. MISCELLANEOUS GROUP “X”

These variables are available from version 02.01 on.

XV0

XV1

XV2

Function:

Example:

(S0)

(F1900)

(F1901)

NullId

One

Zero

Serves to force a "1" or a "0" at a digital output.

Write a "0" so a digital input does not perform any function.

OP10 = XV1

IP12 = 0

Sets the logical output to a logic state "1".

Removes any functionality from the digital input.

A - 56 Parameters, Variables and Commands Ver. 0002

S- 55

S- 57

S- 58

S- 76

S- 80

S- 84

S- 85

S- 87

S- 88

S- 89

S- 90

S- 91

S- 32

S- 36

S- 40

S- 41

S- 42

S- 43

S- 44

S- 47

S- 49

S- 50

S- 51

S- 52

S- 53

S- 54

S- 13

S- 14

S- 15

S- 16

S- 17

S- 21

S- 22

S- 24

S- 25

S- 28

S- 29

S- 30

S- 0

S- 1

S- 2

S- 3

S- 4

S- 5

S- 6

S- 7

S- 8

S- 9

S- 10

S- 11

S- 12

S- 95

S- 96

S- 99

S- 100

S- 101

S- 103

S- 104

S- 106

S- 107

S- 108

S- 109

S- 110

S- 111

S- 113

S- 115

S- 117

S- 121

S- 122

S- 123

P P 55

P P 57

P P 58

P P 76

T V 1

T V 2

T P 85

Q V 87

Q V 88

Q V 89

Q V 90

S P 10

A P 1

S V 1

S V 2

P P 41

P P 42

S P 43

S P 44

P V 47

P P 49

P P 50

P V 51

P P 52

P V 53

P P 54

D V 10

Q V 14

Q V 15

Q V 16

Q V 17

Q V 21

Q V 22

Q V 24

Q V 25

Q V 28

Q V 29

G V 2

X V 0

Q V 1

Q V 2

Q V 3

Q V 4

Q V 5

Q V 6

Q V 7

Q V 8

Q V 9

Q V 10

D V 1

D V 9

D V 95

Q V 96

D C 1

S P 1

DiagnosticMessage

SlaveArrangement

ResetClass1Diagnostics

VelocityProportionalGain

S P 2 VelocityIntegralTime

P P 103 ModuloValue

P P 104 PositionKvGain

C P 1 CurrentProportionalGain

C P 2 CurrentIntegralTime

P V 108 FeedrateOverride

M P 4 MotorPeakCurrent

H V 1 DrivePeakCurrent

M P 3

S P 11

MotorContinuousStallCurrent

MotorMaximumSpeed

P P 115 PositionFeedback2Type

N P 117 ResolutionOfFeedback2

N P 121 InputRevolutions

N P 122 OutputRevolutions

N P 123 FeedConstant

NullId

ControlUnitCycleTime

CommunicationCycleTime

ShortestATTransmisionStartingTime

TransmitReceiveTransitionTime

MinimumFeedbackProcessingTime

ATTransmisionStartingTime_T1

FeedbackAcquisitionPoint_T4

CommandValidTime_T3

PositionOfDataRecordInMDT

LengthOfMDT

Class1Diagnostics (Errors)

Class2Diagnostics (Warnings)

Class3Diagnostics (OperationStatus)

InterfaceStatus

TelegramTypeParameter

ConfigurationListOfAT

IDNListOfAllOperationData

IDNListOfInvalidOperationDataForCP2

IDNListOfInvalidOperationDataForCP3

ConfigurationListOfMDT

IDNListOfAllProcedureCommands

MSTErrorCounter

MDTErrorCounter

ManufacturerVersion

PrimaryOperationMode

VelocityCommand

VelocityFeedback

HomingVelocityFast

VelocityPolarityParameter

HomingAcceleration

VelocityDataScalingType

PositionCommand

PositivePositionLimit

NegativePositionLimit

PositionFeedback1

ReferenceDistance1

PositionFeedback2

ReferenceDistance2

PositionPolarityParameters

PositionWindow

Backlash

PositionDataScalingType

TorqueCommand

TorqueFeedback

TorquePolarityParameter

TransmitToTransmitRecoveryTime

ReceiveToReceiveRecoveryTime

MDTTransmissionStartingTime_T2

CommandValueProceedingTime

VelocityLimit

S- 209

S- 210

S- 211

S- 212

S- 216

S- 217

S- 218

S- 219

S- 254

S- 255

S- 258

S- 259

S- 173

S- 175

S- 176

S- 185

S- 186

S- 187

S- 188

S- 189

S- 193

S- 201

S- 202

S- 204

S- 205

S- 207

S- 142

S- 143

S- 146

S- 147

S- 148

S- 150

S- 151

S- 157

S- 158

S- 159

S- 171

S- 172

S- 124

S- 125

S- 126

S- 127

S- 128

S- 134

S- 135

S- 138

S- 140

S- 141

S- 331

S- 332

S- 333

S- 336

S- 337

S- 342

S- 343

S- 348

S- 349

S- 380

S- 260

S- 262

S- 264

S- 267

S- 296

S- 301

S- 303

S- 305

S- 307

S- 315

S- 323

S- 330

S P 42 StandStillWindow

S P 40

T P 1

VelocityThresholdNx

TorqueThresholdTx

Q V 127 CP3TransitionCheck

Q V 128 CP4TransitionCheck

D V 32 MasterControlWord

D V 31 DriverStatusWord

S P 60

G V 9

M P 1

AccelerationLimit

DriveType

MotorType

D P 142 ApplicationType

Q V 143 SercosInterfaceVersion

P C 146 NCControlledHoming

P P 147 HomingParameter

P C 148 DriveControlledHoming

P P 150 ReferenceOffset1

P P 151 ReferenceOffset2

S P 41 VelocityWindow

T P 2 PowerThresholdPx

P P 159 MonitoringWindow

P C 171 CalculateDisplacement_C

P C 172 DisplacementToTheReferenceSystem

S P 6

S P 7

S P 4

S P 5

G C 2

G V 22

G V 26

G V 20

G V 21

G V 25

P V 58

P V 59

P V 173 MarkerPositionA

P V 175 DisplacementParameter1

P V 176 DisplacementParameter2

Q V 185 MaxLengthOfAT

Q V 186 MaxLengthOfMDT

Q V 187 IDNListOfConfigurableAT

Q V 188 IDNListOfConfigurableMDT

P V 189 FollowingError

P V 193 PositioningJerk

K V 5

K V 9

K V 8

K V 12

G P 9

MotorTemperatureWarningLimit

CoolingTemperatureWarningLimit

MotorTemperatureErrorLimit

CoolingTemperatureErrorLimit

DriveOffDelayTime

VelocityAdaptationLowerLimit

VelocityAdaptationUpperLimit

VelocityAdaptationProportionalGain

VelocityAdaptationIntegralTime

ParameterSetSwitch

ParameterSetPreselection

GearRatioPreselection

IDNListOfParameterSet

ParameterSetActual

GearRatioActual

TargetPosition

PositioningVelocity

P V 60

G V 10

G C 1

PositioningAcceleration

LoadDefaultsCommand

BackupWorkingMemoryCommand

G V 7 Password

P P 216 VelocityFeedForwardPercentage

N V 31 RealTimeControlBit1IDN

N V 33

N V 35

N V 37

RealTimeControlBit2IDN

RealTimeStatusBit1IDN

RealTimeStatusBit2IDN

P V 115 PositioningVelocityGreaterLimit

P V 123 TargetPositionOutsideOfTravelRange

S V 4 nFeedbackEqualNCommand

S V 5

S V 3

T V 10 nFeedbackEqual0 nFeedbackMinorNx

TGreaterTx

P V 136 InPosition

T V 60 PGreaterPx

P V 142 TargetPositionAttained

P V 143 InterpolatorHalted

P P 217 AccelerationFeedForwardPercentage

S P 80

G V 4

JerkLimit

DCBusVoltage

Parameters, Variables and Commands Ver. 0002 A - 57

C P 31

D V 11

D V 14

E P 1

E P 2

E P 3

E C 1

F P 1

F P 2

F P 20

F P 21

F P 30

F P 31

F P 32

F P 33

F P 34

F P 35

F P 36

F P 37

F P 38

F P 40

G P 1

C P 3

C P 4

C P 5

C P 6

C P 7

C V 10

C V 11

C P 20

C P 30

C V 1

C V 2

C V 3

% V 25

% V 27

% C 1

% C 2

S P 20

S P 21

B V 1

B V 3

B V 7

B V 14

H V 10

H V 11

% V 8

% V 11

% V 12

% V 15

% V 16

% V 20

% V 21

% V 22

% V 23

% V 1

% V 24

K V 6 MotorTemperature

S P 110 VelocityFilterTimeConstant

P V 200 HomeSwitch

P V 203 PositionFeedbackStatus

P V 204 PositionCommandStatus

P V 207 HomingEnable

P V 208 ReferenceMarkerPulseRegistered

% V 2

% V 3

% V 4

% V 5

% V 6

% V 7

CanalVariableDSP1

CanalVariableDSP2

CanalVariableDSP3

VariableDSP0

VariableDSP1

VariableDSP2

VariableDSP3 pVariable0 pVariable1

Variable0

Variable1

CanalPecDSP0

CanalPecDSP1

VariablePecDSP0

VariablePecDSP1

CanalVariableDSP0

InputGainChange

AD3Offset

Feedback2I0Analog

PositionReferenceGenerator_C

HacerEncoderVirgen

VoltageRpmVolt

RpmRpmVolt

HaltDrivePin

HaltDriveDnc

DriveEnableDnc

NotProgrammableIOs

VsMSC

FlashManufacturerCode

CurrentDerivativeGain

CurrentAdaptationProportionalGain

CurrentAdaptationIntegralTime

CurrentAdaptationLowerLimit

CurrentAdaptationUpperLimit

CurrentUOffset

CurrentVOffset

CurrentLimit

CurrentFilter1TimeConstant

CurrentUFeedback

CurrentVFeedback

CurrentFeedback

CurrentFilter1Damping

FagorDiagnostics

ErrorsInDncFormat

EncoderSimulatorPulsesPerTurn

EncoderSimulatorI0Position

EncoderSimulatorDirection

EncoderSimulatorSetI0

MotorFluxProportionalGain

MotorFluxIntegralTime

MotorBEMFProportionalGain

MotorBEMFIntegralTime

MotorInductance1

MotorInductance2

MotorInductance3

MotorInductance4

MotorInductance5

MotorInductance6

MotorInductance7

MotorInductance8

MotorInductance9

FluxReduction

PwmFrecuency

F- 300

F- 301

F- 302

F- 303

F- 304

F- 305

F- 306

F- 307

F- 308

F- 309

F- 310

F- 311

F- 18

F- 19

F- 20

F- 21

F- 31

F- 81

F- 201

F- 202

F- 203

F- 204

F- 290

F- 291

F- 7

F- 8

F- 9

F- 10

F- 11

F- 12

F- 13

F- 14

F- 15

F- 16

F- 17

F- 1

F- 2

F- 3

F- 4

F- 5

F- 6

S- 383

S- 392

S- 400

S- 403

S- 404

S- 407

S- 408

F- 312

F- 404

F- 405

F- 500

F- 501

F- 502

F- 503

F- 600

F- 601

F- 602

F- 603

F- 604

F- 605

F- 606

F- 607

F- 608

F- 609

F- 610

F- 611

F- 612

F- 613

F- 700

Feedback1Type

StoppingTimeout

SetNumber

ParameterVersion

ParameterChecksum

CodeChecksum

AccessLevel

SoftReset

PowerBusStatus

PowerVoltageMinimum

ParameterSetAck

ParameterSetStb

ParameterSetBit0

ParameterSetBit1

ParameterSetBit2

TMODE_Select

GearRatioNumber

PlcResourceData

Feedback2Type

OverloadTimeLimit

OverloadVelocityThreshold

KernelResourceData

ModularOrCompact

AnalogReferenceSelect

I1IDN

I2IDN

I3IDN

I4IDN

AnalogInput1

AnalogInput2

DigitalInputs

DigitalInputsCh2

DigitalInputsVoltage

OsciloBuffer1Id

OsciloBuffer2Id

OsciloBuffer3Id

OsciloBuffer4Id

OsciloBuffer1

OsciloBuffer2

OsciloBuffer3

OsciloBuffer4

OsciloBufferLength

OsciloRun

OsciloTriggered

OsciloSamplePeriode

OsciloTriggerLevel

OsciloTriggerPosition

OsciloTriggerEdge

OsciloTraceStart

OsciloTraceCounter

OsciloTriggerBit

OsciloTriggerChanel

OsciloChOneShift

OsciloChTwoShift

OsciloCh1Data

OsciloCh2Data

OsciloStore

DriveTemperature

DriveTemperatureErrorLimit

CoolingTemperature

SupplyPlus5V

SupplyPlus8V

SupplyPlus18V

SupplyMinus5V

SupplyMinus8V

SupplyMinus18V

I2tDrive

I2tMotor

DriveI2tErrorEfect

MotorTorqueConstant

J P 1

J P 2

J P 3

J P 4

J V 5

J V 6

J V 7

J V 8

J P 9

J V 10

J V 11

J P 12

G V 36

H V 9

I P 1

I P 10

I P 11

I P 12

I P 13

I V 1

I V 2

I V 10

I V 11

I P 5

G V 23

G V 24

G V 30

G V 31

G V 32

G V 33

G P 6

G V 35

G P 10

G P 7

G P 8

G P 2

G P 3

G P 4

G P 5

G V 3

G V 5

G V 8

G V 11

G V 13

G V 14

K V 10

K V 20

K V 21

K V 22

K V 23

K V 24

K V 25

K V 32

K V 36

K P 1

M P 2

J P 13

J P 14

J P 15

J V 16

J V 17

J P 18

J P 19

J P 5

J P 6

J V 18

J V 19

J V 20

K V 2

K V 4

F- 1000

F- 1001

F- 1002

F- 1003

F- 1004

F- 1005

F- 1006

F- 1007

F- 1008

F- 1009

F- 1010

F- 1011

F- 722

F- 806

F- 900

F- 901

F- 902

F- 903

F- 904

F- 905

F- 906

F- 907

F- 908

F- 909

F- 711

F- 712

F- 713

F- 714

F- 715

F- 716

F- 717

F- 718

F- 719

F- 720

F- 721

F- 701

F- 702

F- 703

F- 704

F- 705

F- 706

F- 707

F- 708

F- 709

F- 710

F- 1102

F- 1103

F- 1104

F- 1105

F- 1106

F- 1107

F- 1108

F- 1109

F- 1111

F- 1112

F- 1200

F- 1012

F- 1013

F- 1014

F- 1015

F- 1016

F- 1017

F- 1018

F- 1019

F- 1020

F- 1021

F- 1022

F- 1023

F- 1100

F- 1101

A - 58 Parameters, Variables and Commands Ver. 0002

MotorPolesPairs

MotorRatedSupplyVoltage

MotorPowerFactor

MotorConstantPowerEndVelocity

MotorSlip

MotorStatorResistance

MotorStatorInductance

MotorNominalPower

MotorThermalTimeConstant

MotorTempSensorType

MotorShaft

MotorBrake

MotorFan

MotorMounting

MotorBalancing

MotorBearings

MotorPowerReduction

MotorMomentumOfInertia

HomingVelocitySlow

ProcessBlockMode

FeedrateOverrideLimit

PositioningVelocityDefault

KernelOperationMode

KernelAutoMode

KernelStartSignal

KernelStopSignal

KernelResetSignal

KernelAbortSignal

KernelManMode

JogPositiveSignal

JogNegativeSignal

JogVelocity

JogIncrementalPosition

FeedrateOverrideEqualCero

InPositionTime

ProgramPositionOffset

KernelInitError

KernelExecError

DA1IDN

DA2IDN

DA1ValuePer10Volt

DA2ValuePer10Volt

O1IDN

O2IDN

O3IDN

O4IDN

DA1Value

DA2Value

DigitalOutputs

Prog_OutIDN

Prog_Out

DigitalOutputsCh2

FeedbackSineGain

FeedbackCosineGain

FeedbackSineOffset

FeedbackCosineOffset

FeedbackResolverRhoCorrection

FeedbackErrorDisable

FeedbackSine

FeedbackCosine

FeedbackRhoCorrection

FeedbackRadius

EncoderError

StegmannMotorType

CircleAdjust

EncoderParameterStoreCommand

EncoderParameterReadCommand

EncoderType

Feedback2Interface

Feedback2SineGain

P V 24

P P 25

P V 26

P V 27

P V 28

O P 1

O P 2

O P 3

O P 4

O P 10

O P 11

O P 12

P P 12

P V 13

P V 14

P V 15

P V 16

P V 17

P V 18

P V 19

P V 20

P V 21

P P 22

P P 23

M P 15

M P 16

M P 17

M P 18

M P 19

M P 20

M P 22

M P 24

P P 1

P P 10

P P 11

M P 5

M P 6

M P 7

M P 8

M P 9

M P 10

M P 11

M P 12

M P 13

M P 14

R V 2

R V 3

R V 4

R V 6

R V 7

R V 8

R C 1

R C 2

R V 5

R P 10

R P 51

O P 13

O V 1

O V 2

O V 10

O P 5

O V 5

O V 11

R P 1

R P 2

R P 3

R P 4

R P 5

R P 6

R V 1

F- 1324

F- 1325

F- 1326

F- 1327

F- 1328

F- 1400

F- 1401

F- 1402

F- 1403

F- 1404

F- 1405

F- 1406

F- 1312

F- 1313

F- 1314

F- 1315

F- 1316

F- 1317

F- 1318

F- 1319

F- 1320

F- 1321

F- 1322

F- 1323

F- 1211

F- 1212

F- 1213

F- 1214

F- 1215

F- 1216

F- 1218

F- 1220

F- 1300

F- 1310

F- 1311

F- 1201

F- 1202

F- 1203

F- 1204

F- 1205

F- 1206

F- 1207

F- 1208

F- 1209

F- 1210

F- 1507

F- 1508

F- 1509

F- 1510

F- 1511

F- 1512

F- 1513

F- 1514

F- 1515

F- 1516

F- 1550

F- 1407

F- 1408

F- 1409

F- 1410

F- 1411

F- 1412

F- 1413

F- 1500

F- 1501

F- 1502

F- 1503

F- 1504

F- 1505

F- 1506

Parameters, Variables and Commands Ver. 0002 A - 59

F- 1606

F- 1607

F- 1608

F- 1609

F- 1610

F- 1611

F- 1612

F- 1613

F- 1614

F- 1700

F- 1701

F- 1702

F- 1800

F- 1801

F- 1551

F- 1552

F- 1553

F- 1556

F- 1557

F- 1559

F- 1600

F- 1603

F- 1604

F- 1605

F- 1802

F- 1803

F- 1804

F- 1805

F- 1806

F- 1807

F- 1808

F- 1900

F- 1901

F- 2000

F- 2001

F- 2012

F- 2100

F- 2101

F- 2102

F- 2200

W V 3

W V 4

W V 5

W V 6

W V 7

W V 8

W V 9

X V 1

X V 2

Q P 11

A P 5

G V 37

D P 1

D V 15

D V 16

N P 1

R P 52

R P 53

R P 54

R V 51

R V 52

R V 54

S P 12

S P 30

S P 31

S P 61

Feedback2CosineGain

Feedback2SineOffset

Feedback2CosineOffset

Feedback2Sine

Feedback2Cosine

Feedback2Radius

MotorRatedSpeed

AnalogInputOffset1

AnalogInputOffset2

AccelerationLimitVelocity2

S P 62

S P 63

S P 64

AccelerationLimit2

AccelerationLimitVelocity3

AccelerationLimit3

S P 65

S P 70

EmergencyAcceleration

AccelerationOnEmergency

S P 100 AccelerationLimitOn

S V 7

S V 8

VelocityCommandFinal

VelocityCommandBeforeFilters

S P 111 VelocityFilterDamping

T V 50 PowerFeedback

T V 3 PowerFeedbackPercentage

T V 100 TorqueStatus

W V 1

W V 2

GeneratorShape

GeneratorPeriod

GeneratorAmplitude

GeneratorType

GeneratorOutput

GeneratorDutyCycle

GeneratorWaves

GeneratorOn

GeneratorOffset

One

Zero

SercosMbaud

PlcPrgScanTime

PlcErrors

ErrorsDisables

ErrorDisable

ErrorEnable

ReducedActuatedMomentumOfInertiaPercentage

A - 60 Parameters, Variables and Commands Ver. 0002

Velocity

Loop

Current

Loop

From Rotor Sensor

S V 2

S V 7

Speed-PI

SP1, SP2,

SP4, SP5,

SP6, SP7.

Current

LP-Filter

CP30

CP31

Out

In

Analog Input 2

X7(3)

X7(2)

P 2

S P 3 1

DS1

IV 2

IP1=2

Voltage/Current

IV 1

S P 3 0

SERCOS

Interface

S P 2 0

S P 2 1 ra tio

Id<>0

Id=0

Id

S V 1

W V 5

WV4=0

W V 4 = 1

ErrorStop OR

SpeedEnable Function

means

PWM_OFF if the motor has not stopped in a time period GP3

Halt Function

SpeedEnable Function

Error Stop

O R

O R

S V 8

P 1

X7(5)

X7(4)

Analog Input 1

WV1, WV2, WV3,

WV4, WV5.

Command Management

Ramps

Jerk

S P 6 0 ...

...S P 6 4

S P 6 0

S P 8 0

Acc. Emerg.

S P 6 5

S P 8 0 = 0

S P 8 0 < > 0

S P 7 0 = 1

S P 7 0 = 0

S P 1 0 0 = 1

S P 1 0 0 = 0

S P 1 0

S V 7

User notes:

A - 62 Parameters, Variables and Commands Ver. 0002

Errors Ver. 0002

APPENDIX B:

LIST OF ERRORS

WARNINGS

AND

TROUBLESHOOTING

B - 1

List of errors and warnings: (page)

EFFECT OF THE SYSTEM ERRORS .......................................................................................... 4

LIST OF ERRORS ......................................................................................................................... 5

3

4

1

2

5

Internal Error. ..................................................................................................................................................................... 5

Internal Error. ..................................................................................................................................................................... 5

While having torque, there is a voltage drop at the Power Bus. ................................................................................... 5

Emergency stop and time limit "GP3" exceeded. .......................................................................................................... 5

Code Checksum Error. ..................................................................................................................................................... 5

6 Error on the Sercos board. ............................................................................................................................................... 5

50 - 55 Internal PLC compiling error ..................................................................................................................................... 5

66 - 69 PLC execution error .................................................................................................................................................... 5

100 Internal +5 Voltage out of range (old error 16) ............................................................................................................ 5

101 Internal -5 Voltage out of range (old error 17) ............................................................................................................. 5

102 Internal +8 Voltage out of range (old error 18) ............................................................................................................ 5

103 Internal -8 Voltage out of range (old error 19) ............................................................................................................. 5

104 Internal +18 Voltage out of range. .................................................................................................................................... 5

105 Internal -18 Voltage out of range. ..................................................................................................................................... 5

106 Outside temperature on the heatsink. (Heatsink of the IGBTs) .................................................................................... 5

107 Drive overtemperature. (CPU board) ............................................................................................................................. 6

108 Motor overtemperature. .................................................................................................................................................... 6

109 Overvoltage at digital inputs. ............................................................................................................................................ 6

150 Travel limit overrun. ........................................................................................................................................................... 6

152 Command module exceeded. ......................................................................................................................................... 6

154 Excessive Feedforward velocity command. ................................................................................................................... 6

155 Excessive Feedforward acceleration command. ........................................................................................................... 6

156 Excessive following error. ................................................................................................................................................. 6

200 Speed overrun. .................................................................................................................................................................. 6

201 Motor overload. .................................................................................................................................................................. 6

202 Drive overload. .................................................................................................................................................................. 6

203 Torque overload error. ...................................................................................................................................................... 6

211 Internal Error. ..................................................................................................................................................................... 7

212 Overcurrent. ....................................................................................................................................................................... 7

213 Undervoltage at the IGBT drive. ....................................................................................................................................... 7

214 Short-circuit. ...................................................................................................................................................................... 7

215 Overvoltage at the Power Bus of the drive (hard). .......................................................................................................... 7

250 - 253 Homing error. .......................................................................................................................................................... 7

300 Overtemperature at the heatsink of the Power Supply, or Compact module. .............................................................. 7

301 Overtemperature at the Ballast of the Power Supply, or Compact module. ................................................................. 7

302 Short-circuit at the Ballast of the Power Supply module. ............................................................................................... 7

303 Supply voltage of the Ballast circuit driver out of range. ................................................................................................ 7

304 Overvoltage at the power bus of the PS. ......................................................................................................................... 7

305 Protocol error at the interface between the Power Supply and the Drive. .................................................................... 8

306 Overvoltage at the power bus of the drive (soft). ............................................................................................................ 8

307 Undervoltage at the Power Bus. ...................................................................................................................................... 8

308 Overcurrent in the regenerating circuit. ........................................................................................................................... 8

309 Short-circuit at the High Side IGBT. ................................................................................................................................. 8

310 Low voltage at the driver of the High Side IGBT. ............................................................................................................. 8

311 Short-circuit at the Low Side IGBT. .................................................................................................................................. 8

312 Low voltage at the driver of the Low Side IGBT. .............................................................................................................. 8

313 Consumption overcurrent. ............................................................................................................................................... 8

403 MST fault ............................................................................................................................................................................ 9

404 MDT fault ............................................................................................................................................................................ 9

405 Err_InvalidPhase .............................................................................................................................................................. 9

406 Err_PhaseUpshift ............................................................................................................................................................. 9

407 Err_PhaseDownshift ........................................................................................................................................................ 9

500 Inconsistent parameters. ................................................................................................................................................. 9

501 Parameter Checksum Error ............................................................................................................................................ 9

502 Wrong Parameter. ............................................................................................................................................................. 9

503 Wrong default motor values table. .................................................................................................................................. 9

504 Wrong parameter in SERCOS stage two. ...................................................................................................................... 9

505 Connected motor different from the one set in Flash memory ..................................................................................... 9

600 Error in the Communication with the Rotor Encoder. .................................................................................................... 9

601 Error in the Communication with the Rotor Encoder. .................................................................................................... 9

602 Motor feedback B signal saturated. ....................................................................................................................................... 10

603 Motor feedback A signal saturated. ....................................................................................................................................... 10

604 Saturation of the values of motor feedback signal A and/or B. ........................................................................................ 10

607 Saturation of the values of direct feedback signal A and/or B. ......................................................................................... 10

605 Motor feedback signal A and/or B too weak. ........................................................................................................................ 10

608 Direct feedback signal A and/or B too weak. ....................................................................................................................... 10

606 Excessive rotor sensor signal drift. ....................................................................................................................................... 10

700 Error when identifying the serial line board. ........................................................................................................................ 10

701 Error when identifying the VeCon board. .............................................................................................................................. 10

702 Sercos board missing. I/O board missing. ......................................................................................................................... 10

703 Wrong I/O board version. ......................................................................................................................................................... 10

704 Wrong AD selection on the I/O board. ................................................................................................................................... 10

705 Error when identifying the Power board. .............................................................................................................................. 10

706 Error when identifying the motor feedback board. .............................................................................................................. 10

707 Error when identifying the Encoder simulator board. ........................................................................................................ 10

801 Encoder undetected ................................................................................................................................................................. 10

802 Communication error with the Encoder .............................................................................................................................. 10

803 Encoder not initialized .............................................................................................................................................................. 10

804 Defective encoder ..................................................................................................................................................................... 10

805 Encoder detected. ..................................................................................................................................................................... 11

806 Homing error with Sincoder .................................................................................................................................................... 11

900 MC program initialization error ............................................................................................................................................... 11

9xx MC program execution errors ................................................................................................................................................. 11

LIST OF WARNINGS ........................................................................................................................ 12

1

2

3

Inside Overtemperature prior to error 107 ........................................................................................................................... 12

Motor Overtemperature prior to error 108 ............................................................................................................................. 12

Outside temperature at the heatsink prior to error 106 ..................................................................................................... 12

TROUBLESHOOTING .................................................................................................................... 12

The synchronous motor runs away. The axis with encoder simulator runs away. ................................................................. 12

The synchronous motor does not turn smoothly, it applies force but intermittently. .............................................................. 12

The torque of the synchronous motor is low. ................................................................................................................................. 12

The synchronous motor is overheated ........................................................................................................................................... 12

After the setup and with the Drive active, the motor moves. ........................................................................................................ 12

The motor does not turn properly and makes a lot of noise. ...................................................................................................... 12

The motor moves with a lot of noise and when stopped, it seems to jerk. ............................................................................. 12

The following error depends on motor speed. .............................................................................................................................. 12

The motor makes noise and heats up. .......................................................................................................................................... 12

The Ballast kicks in without apparent reason. .............................................................................................................................. 13

The motor loses torque, it does not reach the speed, it does not position properly and it does not repeat position. .... 13

The desired motor cannot be selected, it doesn't seem to be on the motor list. ................................................................... 13

The asynchronous motor, with a light load and requiring great acceleration (much greater than the rated value for the motor) loses control or oscillates. ......................................................................................................................................... 13

The asynchronous motor has no torque. ....................................................................................................................................... 13

While the drive is activated, the spindle vibrates sporadically. Identical or opposed speeds cannot be obtained when changing the sign of the velocity command. ....................................................................................................................... 13

The gear box generates noise. ........................................................................................................................................................ 13

The spindle moves properly but it makes a lot of noise. ............................................................................................................. 13

The motor makes a strange noise when turning, as if the feedback were noisy. .................................................................. 13

Errors Ver. 0002 B - 3

EFFECT OF THE SYSTEM ERRORS

Activating any of the errors listed in this appendix causes certain effects on the system that depend on the type of interface being used.

Analog interface.

The activated error is shown on the drive's display.

Sercos interface.

The activated error is shown on the drive's display.

This error is also displayed on the CNC screen.

The CNC may display the errors listed in this appendix as well as those of the Sercos communication itself.

CNC actions

Activates bit 13 of DV31 -S135-

Activates the bit corresponding to that error in the DV1 -S11- variable.

Interrupts the execution of the program.

Stops the axes and the spindles.

Sets marks /ALARM and O1 to zero. These marks are always present in the PLC program which will handle that emergency without having to know which error has been activated.

Error reset.

The system will not start running until all the errors detected at the drive have been eliminated. To eliminate these errors, their cause has to have disappeared and, then, an

"Error Reset" must be carried out.

This Reset may be carried out via X2(1) of the power supply module, or pin X2(3) of the

Compact Drive.

Certain errors cannot be reset or eliminated with this method. Those errors can only be eliminated by turning the unit off and back on, but provided that the cause for the error has been solved. These errors are:

1

55

502

706

2

100

503

707

5

101

504

801

6

102

700

802

50

103

701

803

51

104

702

804

52

105

703

805

53

109

704

806

54

211

705

900

Stopping the motor.

Activating certain errors cancels the current through the motor. These errors are:

2

55

211

306

606

706

4

66

212

501

607

707

5

67

213

502

608

801

6

68

214

503

700

802

50

69

215

504

701

803

51

109

301

602

702

804

52

200

302

603

703

806

53

202

303

604

704

54

203

304

605

705

B - 4 Errors Ver. 0002

LIST OF ERRORS

1

2

Internal Error.

Get in touch with Fagor Automation.

Internal Error.

Get in touch with Fagor Automation.

3

4

5

6

While having torque, there is a voltage drop at the Power Bus.

- Having torque, a voltage drop has been detected at the Power Bus. Probably one of the three-phase line has dropped or one of the drives has failed.

Check the proper condition of the lines and the drives and restart the system.

Emergency stop and time limit "GP3" exceeded.

- An attempt has been made to stop the motor by disabling "Speed Enable". The system has tried to stop the motor at maximum torque, but it has not been able to stop within the time period set by parameter

GP3 (DriveOffDelayTime = maximum braking time allowed before issuing an error) or the parameter which determines when the motor is considered to be stopped SP42 (MinimumMotorSpeed) is too small

(bear in mind that zero speed or absolute lack of speed is impossible). There is always a small amount of speed "noise" due to feedback.

The load to be stopped by the motor is too great for the time window set by GP3 (increase the value of this parameter). The threshold or speed window considered as zero SP42 is too small (increase the value of this parameter). The module's performance is poor or is unable to stop the motor. The module may be defective.

Code Checksum Error.

- The checksum for the code of the program loaded is not correct.

Reload the software. If the problem persists, the Flash or Ram memories may be defective or the loaded code may defective.

Get in touch with Fagor Automation.

Error on the Sercos board.

Change the board. If the error persists, change the Vecon card.

50 - 55 Internal PLC compiling error

- See the PLC manual for the meaning of this error.

Correct the program.

66 - 69 PLC execution error

- See the PLC manual for the meaning of this error.

100 Internal +5 Voltage out of range (old error 16)

101 Internal -5 Voltage out of range (old error 17)

102 Internal +8 Voltage out of range (old error 18)

103 Internal -8 Voltage out of range (old error 19)

104 Internal +18 Voltage out of range.

105 Internal -18 Voltage out of range.

Get in touch with Fagor Automation.

106 Outside temperature on the heatsink. (Heatsink of the IGBTs)

- The drive is doing something which causes the power devices to overheat.

Stop the system for a few minutes and reduce the amount of effort required of the Drive.

- The drive is exposed to excessive temperature.

Cool it down.

Errors Ver. 0002 B - 5

107 Drive overtemperature. (CPU board)

The ambient temperature of the drive is too high. It must be lowered.

108 Motor overtemperature.

The cables measuring motor temperature (position sensor cables), or the thermistor itself are defective.

The application requires high current peaks.

Stop the system for a few minutes and decrease the amount of effort demanded to the motor. Ventilate the motor.

109 Overvoltage at digital inputs.

- The digital inputs of the drive receive a voltage higher than what they have been set up for.

Check the configuration (parameter IP5 -F00909-) and the electrical voltage applied.

150 Travel limit overrun.

- The travel limits of the axis have been exceeded.

Check the values of these limits and the programming of these movements.

152 Command module exceeded.

- While working with a command in module format, a command has been received whose value exceeds the one set by parameter PP103.

Check the value of this parameter together with its equivalent parameter at the CNC. Check that both the drive and the CNC work in the same command mode.

154 Excessive Feedforward velocity command.

- The path required by the position command causes a feedforward velocity command which is too high.

Decrease the path demands in terms of required feedrate.

155 Excessive Feedforward acceleration command.

- The path required by the position command causes a feedforward acceleration command which is too high.

Decrease the path demands in terms of required acceleration.

156 Excessive following error.

- The axis follows the position command with a "following error" (axis lag) PV189 -S189- FollowingError which is greater than the maximum allowed by PP159 -S159- MonitoringWindow

Check the setting of all these factors involved in "following error". Check the value given to PP159.

200 Speed overrun.

- The motor speed has exceeded the SP10 value by more than 12%.

Problem with the cables of the position sensor or of the motor power. The velocity loop is poorly adjusted.

Decrease the speed overshoot of the response.

201 Motor overload.

202 Drive overload.

- The I 2 t protection of the motor or of the drive has triggered.

The duty cycle is greater than the system can provide.

203 Torque overload error.

- The servo drive is locked up and it can not turn freely. Due to too high a torque, the turning speed has not exceeded the GP8 value for a time period greater than the GP7 value.

Free the motor. If the error comes up for no apparent reason, increase the GP7 and/or GP8 values. If GP7 is set to “0”, the error message is never issued.

B - 6 Errors Ver. 0002

211 Internal Error.

Get in touch with Fagor Automation.

212 Overcurrent.

- Too much current at the Drive module. Drive malfunction.

Reset the error, the parameter settings might be wrong and they cause overcurrent.

213 Undervoltage at the IGBT drive.

- Low supply voltage is detected in the IGBT attack circuitry in the Drive module. Possible failure on the drive of the IGBT or the IGBT itself.

Reset the error, and if this goes on, get in touch with Fagor Automation.

214 Short-circuit.

- Short-circuit at the Drive Module.

Reset the error. If it persists, the power cables might be connected in the wrong order or that they touch each other causing the short-circuit. The parameters might be wrong or there is a Drive malfunction.

Contact Fagor Automation

215 Overvoltage at the Power Bus of the drive (hard).

- The hardware of the drive module has detected excessive voltage at the Power bus. Internal Ballast connection jumper missing (see power connectors). Or, when using an external Ballast, it is not connected properly. The Ballast resistor is burned out.

Power it down and check for proper Ballast circuit connection.

See errors 304 and 306.

250 - 253 Homing error.

Get in touch with Fagor Automation.

300 Overtemperature at the heatsink of the Power Supply, or Compact module.

301 Overtemperature at the Ballast of the Power Supply, or Compact module.

- Temperature of the heatsink or of the Ballast circuit of the Power Supply module too high.

Stop the system for a few minutes and reduce the level of effort required of this module.

302 Short-circuit at the Ballast of the Power Supply module.

Get in touch with Fagor Automation.

303 Supply voltage of the Ballast circuit driver out of range.

Get in touch with Fagor Automation.

304 Overvoltage at the power bus of the PS.

- The power supply has detected excessive voltage at the power bus. The internal Ballast may be disconnected (see Power Supply Module) or, when using an external Ballast, it is not connected.

Turn the power off and check that the lines are OK.

See errors 215 and 306.

Errors Ver. 0002 B - 7

305 Protocol error at the interface between the Power Supply and the Drive.

- Communication errors between the Power Supply module and the Drive through the internal Bus.

Get in touch with Fagor Automation.

- The XPS models can detect a group of errors that drives with software version 03.05 or older cannot indicate at the Status Display. In this case, the XPS models indicate those errors by means of different

LED combinations on their face plate. The following table shows how to interpret those errors.

FAULT

On

On

On

On

On

On

REGEN DC BUS ON

On

On

On

Blink

Blink

Off

Off

On

Blink

On

Blink

On

Error

Sobrecorriente en el circuito de devolución

Cortocircuito en el High Side IGBT

Baja tensión en el driver del High Side IGBT

Cortocircuito en el Low Side IGBT

Baja tensión en el driver del Low Side IGBT

Sobrecorriente en el consumo

308

309

310

311

312

313

306 Overvoltage at the power bus of the drive (soft).

- The software of the drive module has detected excessive voltage at the power bus. The application demands high current peaks and the mains power has too much impedance.

See errors 215 and 304.

307 Undervoltage at the Power Bus.

- The mains voltage is lower than permitted (Rated voltage < 380Vac)

Turn the power off and check that the lines are OK.

308 Overcurrent in the regenerating circuit.

Get in touch with Fagor Automation.

309 Short-circuit at the High Side IGBT.

Get in touch with Fagor Automation.

310 Low voltage at the driver of the High Side IGBT.

Get in touch with Fagor Automation.

311 Short-circuit at the Low Side IGBT.

Get in touch with Fagor Automation.

312 Low voltage at the driver of the Low Side IGBT.

Get in touch with Fagor Automation.

313 Consumption overcurrent.

- The current demanded from the power supply is too high.

Decrease the demands of the duty cycle.

B - 8 Errors Ver. 0002

403 MST fault

404 MDT fault

405 Err_InvalidPhase

406 Err_PhaseUpshift

407 Err_PhaseDownshift

- 400 series errors refer to various communication problems through the fiber optic ring.

Check the connections at the ring and the identification of each module.

500 Inconsistent parameters.

- See error 502.

501 Parameter Checksum Error

- The parameter Checksum has been found to be incorrect.

The Soft version has probably been changed and the new version requires a different number of parameters.

When this error comes up the servo-drive takes the default values of the parameters.

The user has two options:

-

-

Confirm the Default values:

Recover the previous values:

To do this simply save the parameters again.

To do this, load the parameters into RAM and check them out with the PC. If the operator considers that they are valid, he/she can validate them by storing them.

502 Wrong Parameter.

(This error does not come up from software version 03.01 on)

- A parameter has a wrong value: This error indicated an incongruence of a parameter in terms of inexistence, out of limits, etc.

Correct the parameter. The DV16 variable, indicated the code of the wrong parameter.

From software version 03.01 on:

Variable QV22 -S22- contains the list of wrong parameters conflicting with other parameters or merely wrong. For now, this variable can only be seen by means of the "ddssetup.exe" running on DOS.

Correct these parameters.

503 Wrong default motor values table.

(This error does not come up from software version 03.01 on)

The table has not be saved. This table must be saved.

504 Wrong parameter in SERCOS stage two.

- Only with Sercos interface: parameter QV21 -S21- contains the wrong parameter list corresponding to stepping to stage two of the Sercos protocol. For now, it can only be seen by means of the ddssetup.exe

on DOS.

Correct the parameter.

505 Connected motor different from the one set in Flash memory

- The drive RAM memory parameters have been set for the new motor connected. However, the setting of the parameters stored in Flash memory correspond to another motor. In other words, the MP1 value in

Flash and in RAM are not the same. This error does not interrupt the normal operation of the drive.

Save the parameters in Flash memory to work with the connected motor.

600 Error in the Communication with the Rotor Encoder.

601 Error in the Communication with the Rotor Encoder.

(These errors don't come up on software version 03.01 or later). They are displayed as errors 8xx.

Check the sensor cable and if it is the right one, check the sensor itself and the X4 card.

Errors Ver. 0002 B - 9

602 Motor feedback B signal saturated.

- Defective rotor sensor cabling, encoder or X4 card. RP1 (gain of the sine signal of the rotor sensor) or

RP3 (offset of the sine signal of the rotor sensor) is too large.

Check the cable of the Encoder and that of the X4 card or increase the value of these parameters.

603 Motor feedback A signal saturated.

- Defective rotor sensor cabling, encoder or X4 card. The offset and/or gain (RP1, RP2, RP3 and RP4) of the signals is too large.

Check the cable of the Encoder and that of the X4 card or increase the value of these parameters.

604 Saturation of the values of motor feedback signal A and/or B.

607 Saturation of the values of direct feedback signal A and/or B.

- Defective cabling, feedback device or feedback board (connector X4 or X3).

- The value of parameter RP1, RP2, RP3, or RP4 is too high.

Check the cable, the feedback device, the cards or decrease the value of these parameters.

605 Motor feedback signal A and/or B too weak.

608 Direct feedback signal A and/or B too weak.

- Defective cabling, feedback device or feedback board (connector X4 or X3).

- The value of parameter RP1, RP2, RP3, or RP4 is too low.

Check the cable, the feedback device, the cards or increase the value of these parameters.

606 Excessive rotor sensor signal drift.

- The quality of the signals has dropped. Wiring of the rotor sensor faulty,

Encoder faulty, X4 card faulty or ground connection faulty.

Check the state of the cable, of the Encoder or of the X4 card, or the ground connections.

700 Error when identifying the serial line board.

701 Error when identifying the VeCon board.

702 Sercos board missing. I/O board missing.

703 Wrong I/O board version.

704 Wrong AD selection on the I/O board.

705 Error when identifying the Power board.

706 Error when identifying the motor feedback board.

707 Error when identifying the Encoder simulator board.

The 700 series errors refer to the improper operation of the hardware or that any of the necessary boards is missing. Contact Fagor Automation.

801 Encoder undetected

Parameter GP2 has been set to "0" (sinewave encoder) and the motor feedback is actually a Resolver.

The value of GP2 must be consistent with the feedback device installed. Contact Fagor Automation.

802 Communication error with the Encoder

Contact Fagor Automation.

803 Encoder not initialized

Contact Fagor Automation.

804 Defective encoder

The Encoder is not working properly.

Contact Fagor Automation.

B - 10 Errors Ver. 0002

805 Encoder detected.

The Drive has been set to have a Resolver (GP2) and the motor feedback is not of this type.

Maybe the motor has an Encoder instead of a Resolver.

The value of GP2 must be consistent with the feedback device installed. Contact Fagor Automation.

806 Homing error with Sincoder

Contact Fagor Automation.

900 MC program initialization error

Refer to the MC manual for the meaning of this error.

9xx MC program execution errors

Refer to the MC manual for the meaning of this error.

Errors Ver. 0002 B - 11

LIST OF WARNINGS

1

2

3

A warning on the 7-segment display appears with an "A" instead of an "E" which is used to display errors. Warnings indicate that the Drive is getting to an error limit.

Inside Overtemperature prior to error 107

Motor Overtemperature prior to error 108

Outside temperature at the heatsink prior to error 106

The warning temperature (KV1, KV5 or KV9, respectively) has been exceeded.

TROUBLESHOOTING

This section is intended to be an assistance to solve some of the typical problems that come up when installing the Servo Drive system.

The synchronous motor runs away. The axis with encoder simulator runs away.

Wrong encoder absolute position offset, or Resolver installed wrong.

Change the counting direction of the encoder signals, modify EP3.

Motor with sinewave encoder whose parameters have been set for a squarewave encoder. Modify GP2.

The synchronous motor does not turn smoothly, it applies force but intermittently.

The power phases between the drive and the motor are not cabled correctly.

The signal phases between the drive and the rotor sensor are not cabled correctly.

The torque of the synchronous motor is low.

Check the system's current limit. CP20. Wrong encoder absolute position offset.

The encoder, or resolver, has moved from the correct position.

The synchronous motor is overheated

Wrong encoder absolute position offset. Motor calculated wrong. Vertical axis not compensated. Too much friction.

After the setup and with the Drive active, the motor moves.

Resolver feedback has been selected while actually using an encoder, modify GP2.

The motor does not turn properly and makes a lot of noise.

The resolver cable shield is not connected to connector X4 of the drive module. Pin 26.

The motor moves with a lot of noise and when stopped, it seems to jerk.

The encoder cable shield is connected at the motor end.

The following error depends on motor speed.

It is due to the effect of the PI which varies depending on speed (SP1, 2, 4, 5, 6, 7). Try adjusting it so this does not happen. Remember that the minimum following error is only required for machining not for moving.

The motor makes noise and heats up.

The resolver or encoder is positioned wrong. The encoder or resolver cable shield is not connected.

B - 12 Errors Ver. 0002

The Ballast kicks in without apparent reason.

The motor cable leaks to ground.

The motor loses torque, it does not reach the speed, it does not position properly and it does not repeat position.

The encoder is loose and its rotor shifts with respect to the rotor of the motor.

The desired motor cannot be selected, it doesn't seem to be on the motor list.

The loaded drive software is older than version V01.04 and data D01.06. These versions did not have all the possible motors.

The asynchronous motor, with a light load and requiring great acceleration (much greater than the rated value for the motor) loses control or oscillates.

The solution consists in applying an acceleration ramp providing a smoother speed transition (SP60, 61,

62, 63 and 64).

The asynchronous motor has no torque.

Low current limit value, CP20.

While the drive is activated, the spindle vibrates sporadically. Identical or opposed speeds cannot be obtained when changing the sign of the velocity command.

There is poor ground connection or a leak at the cable carrying the velocity command.

The gear box generates noise.

The velocity command must be continuous. Apply ramps to velocity commands, limit the jerk (ramps in S) or install an external filter.

The spindle moves properly but it makes a lot of noise.

The electrical connection to the asynchronous motor is wrong. Instead of being a star connection it is a triangle. The encoder cable shield is loose at the motor end.

The motor makes a strange noise when turning, as if the feedback were noisy.

The rotor sensor cable has a shield in electrical contact with the body of the motor.

Errors Ver. 0002 B - 13

User notes:

B - 14 Errors Ver. 0002

APPENDIX C:

REFERENCES

OF FAGOR

PRODUCTS

References Ver. 0002 C - 1

C - 2

Motor references

AXIS MOTORS, FXM Example: FXM 34.30A . E1 . 0 0 0

FAGOR AXIS MOTOR

SIZE

LENGTH

MAXIMUM

SPEED

1, 3, 5, 7

12 1200 rpm 20 2000 rpm

30 3000 rpm 40 4000 rpm

A 380 Vac WINDING

FEEDBACK TYPE E0 Encoder Sincos TM

(Except for FXM1 type)

E1 Encoder Sincoder TM

A0 Encoder Absoluto Sincos TM

(Except for FXM1 type)

R0 Resolver Tamagawa TM

FLANGE AND

SHAFT

0 With Keyway (Siemens TM 1FT5)

1 Without Keyway

BRAKE OPTION 0 Without brake

1 With standard brake (24 Vdc)

VENTILATION 0 Without Fan

1 With Fan (220 Vac)

SPINDLE MOTORS, SPM xx.0

Example: SPM 100LBE . E 1 . 0 0 0 0 0 . 0

SPINDLE MOTOR

MOTOR MODEL

(rated power

in S1/S6-40%

-kW-)

FEED-BACK

90L 2.2/3.3 90P 3/4

100LBE 4/6 112ME 5.5/8

112LE 7.5/11 112XE 11/16

132L 15/22 132X 18.5/26

132XL 22/28 160M 22/33

160L 30/45 180MA 37/55

E0 Encoder Sincos TM

E1 Encoder Sincoder TM

MOUNTING

FLANGE AND

SHAFT 1

2

3

0 Standard

Protection Seal

Flange for mounting on ZF boxes

Without keyway

4..9

Special flange or shaft

BALANCING

GRADE

0 S, standard balancing grade

1 SR, balancing grade

BRAKE OPTION

0 B3/B5 Horizontal (standard)

1 V1/V5 Vertical downward

2 V3/V6 Vertical upward

BEARINGS

0 Without brake

1 With standard brake (220 Vac)

0 Standard

1 Special, high speed

References Ver. 0002

SPINDLE MOTORS, SPM xx.1

Example:

SPM 100LBE . E 1 . 0 0 0 0 0 . 1

SPINDLE MOTOR

MOTOR MODEL

(rated power

in S1/S6-40%

-kW-)

90L 2.2/3.3 90P 3/4

100LBE 4/6 112ME 5.5/8

112LE 7.5/11 112XE 11/16

132L 15/22 132X 18.5/26

132XL 22/28 160M 22/33

FEED-BACK

MOUNTING

E0 Encoder Sincos TM

E1 Encoder Sincoder TM

0 B3/B5 Horizontal (standard)

1 V1/V5 Vertical downward

2 V3/V6 Vertical upward

FLANGE AND

SHAFT

BALANCING

GRADE

0 Standard

1

2

Protection Seal

Flange for mounting on ZF boxes

3 Without keyway

4..9

Special flange or shaft

0 S, standard balancing grade

1 SR, balancing grade

BRAKE OPTION

BEARINGS

0 Without brake

1 With standard brake (220 Vac)

0 Standard

1 Special, high speed

References Ver. 0002 C - 3

C - 4

References of Modular Drives

AXIS DRIVE, AXD

AXIS DRIVE

SIZE

CURRENT

(nominal, peak)

INTERFACE

ADDITIONAL

FEEDBACK

FEATURES

Example:

1 Width 77mm (08, 15, 25, 35 Amp)

2 Width 117mm (50, 75 Amp)

3 Width 234mm (100, 150 Amp)

08 (4 Amp, 8 Amp)

15 (7.5 Amp, 15 Amp)

25 (12.5 Amp, 25 Amp)

35 (17.5 Amp, 35 Amp)

50 (25 Amp, 50 Amp)

75 (37.5 Amp, 75 Amp)

100 (50 Amp, 100 Amp)

150 (75 Amp, 150 Amp)

0

1

2

A1 Analog

SI Sercos

S0 Sercos & Analog

None

Encoder simulator

Direct feedback

AXD 1 . 25 - A1 - 0

SPINDLE DRIVE, SPD

SPINDLE DRIVE

SIZE

CURRENT

(in any duty cycle)

INTERFACE

ADDITIONAL

FEEDBACK

FEATURES

1 Width 77mm

2 Width 117mm

3 Width 234mm

08 (5.6 Amp)

15 (10.6 Amp)

25 (19.6 Amp)

35 (28.5 Amp)

50 (35.4 Amp)

75 (53 Amp)

100 (80 Amp)

150 (106 Amp)

0

1

2

A1 Analog

SI Sercos

S0 Sercos & Analog

None

Encoder simulator

Direct feedback

Example:

SPD 2 . 50 - SI - 0

References Ver. 0002

References Ver. 0002

POWER SUPPLY, PS

POWER SUPPLY (Mains voltage of 380-460 Vac)

POWER

(power, rated current)

25A (25 kw, 45 Amp)

65A (65 kw, 120 Amp)

The old PS-xx admitted a mains voltage of 380 Vac.

Example:

PS - 25A

PS POWER SUPPLY

WITH INTEGRATED AUXILIARY 24 Vdc POWER SUPPLY

Example:

PS - 25B

POWER SUPPLY (Mains voltage of 380-460 Vac)

POWER

(power, rated current)

25B (25 kw, 45 Amp)

(24 Vdc, 8 Amp)

REGENERATIVE

POWER SUPPLY, XPS

X-circuit POWER SUPPLY

POWER

(power, rated current)

25 (25 kw, 45 Amp)

65 (65 kw, 120 Amp)

Example:

XPS - 25

Metric

Conversion table to mm

Kg·m 2

Nm

°C

Kw

÷ 25.4

÷ 0.113

÷ 0.113

x 1.8

+ 32

÷ 0.746

Imperial inch lb·in·sec 2 lb·in

°F

HP

C - 5

C - 6

References of Compact Drives

AXIS COMPACT DRIVE, ACD

AXIS COMPACT DRIVE

SIZE 1 Width 117mm (8/15/25 Amp)

2 Width 194mm (50/75 Amp)

CURRENT

(nominal, peak)

INTERFACE

ADDITIONAL

FEEDBACK

FEATURES

08 (4 Amp, 8 Amp)

15 (7.5 Amp, 15 Amp)

25 (12.5 Amp, 25 Amp)

50 (25 Amp, 50 Amp)

75 (37.5 Amp, 75 Amp)

0

1

2

A1 Analog

SI Sercos

S0 Sercos & Analog

None

Encoder simulator

Direct feedback

Example:

ACD 1 . 25 - A1 - 1

SPINDLE COMPACT DRIVE, SCD

SPINDLE COMPACT DRIVE

SIZE 1 Width 117mm

2 Width 194mm

CURRENT

(in any duty cycle)

INTERFACE

ADDITIONAL

FEEDBACK

FEATURES

08 (5.6 Amp)

15 (10.6 Amp)

25 (17.7 Amp)

50 (35.4 Amp)

75 (53 Amp)

0

1

2

A1 Analog

SI Sercos

S0 Sercos & Analog

None

Encoder simulator

Direct feedback

Example:

SCD 2 . 50 - SI - 0

References Ver. 0002

References of other necessary elements.

ACCESORY MODULES

FAGOR MAINS FILTER

MAXIMUM CURRENT

3040

3120

40 Amp

120 Amp

AUXILIARY POWER SUPPLY (24 Vdc)

CAPACITOR MODULE (4 mF)

RESISTOR MODULE (18 Ohms, 1500 Watts)

PORTABLE PROGRAMMING MODULE

Example: EMK 3040

APS 24

CM-60

RM-15

DDS PROG MODULE

EXTERNAL RESISTOR (43 Ohms, 350 Watts)

(24 Ohms, 750 Watts)

(18 Ohms, 1100 Watts)

ER-43/350

ER-24/750

ER-18/1100

INDUCTANCE FOR XPS

CHOKE INDUCTIVE FILTER FOR THE XPS

XPS POWER SUPPLY For the XPS-25, or XPS-65

Example: CHOKE XPS-25

SOFTWARE

INITIALIZING, SET-UP AND MONITORING SOFTWARE

SIGNAL CABLES

EEC ENCODER EXTENSION CABLE

REC RESOLVER EXTENSION CABLE

SEC SIGNAL (SIMULATOR) EXTENSION CABLE

LENGTH (m) 1, 3, 5, 10, 15, 20, 25.

Example: EEC - 20

DDS-SETUP

References Ver. 0002 C - 7

FIBER OPTIC LINES

SFO SERCOS FIBER OPTIC

LENGTH (m) 1, 2, 3, 5, 7.

Example: SFO - 2

POWER CABLES

MOTOR POWER CABLE

LINES x SECTION (mm 2 )

LINES x SECTION (mm 2 )

Example: MPC - 4 x 10 + (2 x 1)

CONNECTORS FOR THE MOTORS

POWER CONNECTOR FOR FXM

Example: MC 23

AMC Angled

MC Vertical

MAXIMUM CURRENT 23 (23 Amp)

46 (46 Amp)

80 (80 Amp)

ENCODER FEEDBACK CONNECTOR (12 pins)

RESOLVER FEEDBACK CONNECTOR (9 pins)

E0C 12

R0C 9

Ordering example.

FAGOR AUTOMATION S. COOP.

QTY REFERENCE

1

1

1

2

2

1

1

2

1

3

FXM 33.30A .R0.000

FXM 33.30A .R0.000

MC 23

A XD 1.15-A 1-1

S PM 112LE .E 0.00000.0

S PD 2.50-A 1-1

P S-25A

REC - 5

E EC - 5

S EC - 1

TOTAL DRIV E S YSTEM

DESCRIPTION

A xis Motor 5,77 Nm, 3.000 with resolver

A xis Motor 5.77 Nm, 3,000 with resolver

Motor power connectors (socket)

15 A m p axis drives with encoder sim ulator

7.5 K w S1 spindle (1,500 at 7,500 rpm)

50 A m p spindle drive with encoder simulator

25 K w P ower supply

5 m Resolver extension Cable

5 m Resolver extension Cable

1m S ignal E ncoder Cable

UNIT

PRICE

US $

NET

PRICE

US $

C - 8 References Ver. 0002

Manufacturing Codes

POWER SUPPLIES AND ACCESSORIES

PS-25

PS-65

84070000

84070002

XPS-25 84070005

XPS-65 84070006

84070003

84070004

PS-25A

PS-65A

PS-25B

APS 24 84090001

CHOKE XPS-65

CM-60

RM-15

84090011

84070010

84070011

POWER-PRO 110A

EMK 3120

DDS PROG MODULE

ER-43/350

ER-24/750

ER-18/1100

CABLES AND CONNECTORS

EEC-5 84080003

EEC-10 84080004

EEC-15 84080005

MPC-4x1,5

MPC-4x2,5

MPC-4x4

EEC-20 84080006

EEC-25 84080007

MPC-4x6

MPC-4x10

MPC-4x16

SEC-1 84040050

SEC-3 84040051

SEC-5 84040052

SEC-10 84040053

REC-5

REC-10

REC-15

84080010

84080011

84080012

MPC-4x1,5+(2x1)

MPC-4x2,5+(2x1)

MPC-4x4+(2x1)

SEC-15 84040054

SEC-20 84040055

MPC-4x6+(2x1)

MPC-4x10+(2x1)

MPC-4x16+(2x1,5)

MPC-4x25+(2x1)

MPC-4x35+(2x1)

REC-20

REC-25

84080013

84080014

ENCODER CABLE

RESOLVER CABLE

84040040

84040041

OTHERS

DDS-SETUP 84080150 MAN REGUL (CAS)

MAN REGUL (IN)

MAN DDS MC (CAS)

MAN DDS MC (IN)

04040152

04040153

04040154

04040155

04040156

04040157

04040165

04040166

04040167

04040168

04040169

04040170

04040173

04040174

AMC 23

R0C 9

SFO-1

SFO-2

SFO-3

SFO-5

SFO-7

04754000

04754001

04754010

04754011

MODULAR QUICK REF

COMPACT QUICK REF

04600052

04600060

04600061

84090000

84200002

84200003

84200004

84080050

84080051

84080052

84080053

84080110

84080111

83900010

83900011

83900012

83900013

83900014

14460010

14460012

References Ver. 0002 C - 9

C - 10

MODULAR AXES DRIVES

AXD 1.08-A1-0

AXD 1.08-A1-1

AXD 1.15-A1-0

AXD 1.15-A1-1

AXD 1.25-A1-0

AXD 1.25-A1-1

AXD 1.35-A1-0

AXD 1.35-A1-1

AXD 2.50-A1-0

AXD 2.50-A1-1

AXD 2.75-A1-0

AXD 2.75-A1-1

AXD 3.100-A1-0

AXD 3.100-A1-1

AXD 3.150-A1-0

AXD 3.150-A1-1

84010000 AXD 1.08.S0.0

84010001 AXD 1.08.S0.1

84010015 AXD 1.15.S0.0

84010016 AXD 1.15.S0.1

84010030 AXD 1.25.S0.0

84010031 AXD 1.25.S0.1

84010050 AXD 1.35-S0-0

84010051 AXD 1.35-S0-1

84010060 AXD 2.50.S0.0

84010061 AXD 2.50.S0.1

84010075 AXD 2.75.S0.0

84010076 AXD 2.75.S0.1

84010100 AXD 3.100.S0.0

84010101 AXD 3.100.S0.1

84010115 AXD 3.150.S0.0

84010116 AXD 3.150.S0.1

MODULAR SPINDLE DRIVES

SPD 1.08-A1-0

SPD 1.08-A1-1

SPD 1.15-A1-0

SPD 1.15-A1-1

SPD 1.25-A1-0

SPD 1.25-A1-1

SPD 1.35-A1-0

SPD 1.35-A1-1

SPD 2.50-A1-0

SPD 2.50-A1-1

SPD 2.75-A1-0

SPD 2.75-A1-1

SPD 3.100-A1-0

SPD 3.100-A1-1

SPD 3.150-A1-0

SPD 3.150-A1-1

84050000 SPD 1.08-S0-0

84050001 SPD 1.08-S0-1

84050015 SPD 1.15-S0-0

84050016 SPD 1.15-S0-1

84050030 SPD 1.25-S0-0

84050031 SPD 1.25-S0-1

84050080 SPD 1.35-S0-0

84050081 SPD 1.35-S0-1

84050050 SPD 2.50-S0-0

84050051 SPD 2.50-S0-1

84050065 SPD 2.75-S0-0

84050066 SPD 2.75-S0-1

84050100 SPD 3.100-S0-0

84050101 SPD 3.100-S0-1

84080115 SPD 3.150-S0-0

84050116 SPD 3.150-S0-1

COMPACT AXES DRIVES

ACD 1.08-A1-0

ACD 1.08-A1-1

ACD 1.15-A1-0

ACD 1.15-A1-1

ACD 1.25-A1-0

ACD 1.25-A1-1

ACD 2.50-A1-0

ACD 2.50-A1-1

ACD 2.75-A1-0

ACD 2.75-A1-1

84060000 ACD 1.08.S0.0

84060001 ACD 1.08.S0.1

84060010 ACD 1.15.S0.0

84060011 ACD 1.15.S0.1

84060020 ACD 1.25.S0.0

84060021 ACD 1.25.S0.1

84060100 ACD 2.50.S0.0

84060101 ACD 2.50.S0.1

84060120 ACD 2.75.S0.0

84060121 ACD 2.75.S0.1

COMPACT SPINDLE DRIVES

SCD 1.08-A1-0

SCD 1.08-A1-1

SCD 1.15-A1-0

SCD 1.15-A1-1

SCD 1.25-A1-0

SCD 1.25-A1-1

SCD 2.50-A1-0

SCD 2.50-A1-1

SCD 2.75-A1-0

SCD 2.75-A1-1

84060030 SCD 1.08.S0.0

84060031 SCD 1.08.S0.1

84060040 SCD 1.15.S0.0

84060041 SCD 1.15.S0.1

84060050 SCD 1.25.S0.0

84060051 SCD 1.25.S0.1

84060200 SCD 2.50.S0.0

84060201 SCD 2.50.S0.1

84060220 SCD 2.75.S0.0

84060221 SCD 2.75.S0.1

84010013 AXD 1.08-SI-0

84010014 AXD 1.08-SI-1

84010028 AXD 1.15-SI-0

84010029 AXD 1.15-SI-1

84010043 AXD 1.25-SI-0

84010044 AXD 1.25-SI-1

84010045 AXD 1.35-SI-0

84010046 AXD 1.35-SI-1

84010073 AXD 2.50-SI-0

84010074 AXD 2.50-SI-1

84010088 AXD 2.75-SI-0

84010089 AXD 2.75-SI-1

84010113

84010114

84010128

84010129

AXD 3.100-SI-0

AXD 3.100-SI-1

AXD 3.150-SI-0

AXD 3.150-SI-1

84050013 SPD 1.08-SI-0

84050014 SPD 1.08-SI-1

84050028 SPD 1.15-SI-0

84050029 SPD 1.15-SI-1

84050043 SPD 1.25-SI-0

84050044 SPD 1.25-SI-1

84050090 SPD 1.35-SI-0

84050091 SPD 1.35-SI-1

84050063 SPD 2.50-SI-0

84050064 SPD 2.50-SI-1

84050078 SPD 2.75-SI-0

84050079 SPD 2.75-SI-1

84050113 SPD 3.100-SI-0

84050114

84050128

84050129

SPD 3.100-SI-1

SPD 3.150-SI-0

SPD 3.150-SI-1

84060150 ACD 1.08-SI-0

84060151 ACD 1.08-SI-1

84060160 ACD 1.15-SI-0

84060161 ACD 1.15-SI-1

84060170 ACD 1.25-SI-0

84060171 ACD 1.25-SI-1

84060180 ACD 2.50-SI-0

84060181 ACD 2.50-SI-1

84060190 ACD 2.75-SI-0

84060191 ACD 2.75-SI-1

84060060 SCD 1.08-SI-0

84060061 SCD 1.08-SI-1

84060070 SCD 1.15-SI-0

84060071 SCD 1.15-SI-1

84060080 SCD 1.25-SI-0

84060081 SCD 1.25-SI-1

84060111 SCD 2.50-SI-0

84060112 SCD 2.50-SI-1

84060131 SCD 2.75-SI-0

84060132 SCD 2.75-SI-1

84010010

84010011

84010025

84010026

84010040

84010041

84010056

84010057

84010070

84010071

84010085

84010086

84010110

84010111

84010125

84010126

84050010

84050011

84050025

84050026

84050040

84050041

84050086

84050087

84050060

84050061

84050075

84050076

84050110

84050111

84050125

84050126

84060006

84060007

84060016

84060017

84060026

84060027

84060106

84060107

84060126

84060127

84060036

84060037

84060046

84060047

84060056

84060057

84060206

84060207

84060226

84060227

References Ver. 0002

ELEMENT

Connection plates (77 mm)

Connection plates (117 mm)

Hex nut M6

Washer B6.4MS

Washer 6AZ

Power connector PC-4, 10-pins + cable

Power connector PC-4, 3-pins

Thermo-Switch connector, 2-pins

1.25 Amp. fuses

1 Amp. fuses

2.5 Amp. fuses

10-wire ribbon cable set

Phoenix 10p. 5mm female connector

Phoenix 7p. 5mm female connector

Phoenix 8p. 5mm female connector

Phoenix 3p. 7.6mm female connector

Phoenix 3p. 5mm female connector

Sub-D 26 HD - Male connector

SUB-D 26pin connector hood

Sub-D 9 pin - female connector

SUB-D 9 pin connector hood

Optional digital and analog I/O board

13 pin female connector

11 pin female connector

Encoder simulator option

Sub-D 15 HD - female connector

SUB-D 9pin connector hood

SERCOS interface option:

250 mm fiber optic cable

(*) Except the AXD and SPD 1.35 modules

POWER SUPPLIES MODULAR DRIVES COMPACTO

DRIVES

ACCESORY

MODULES

PS-25B PS-25A PS-65A XPS-25 XPS-65 APS 24 AXD 1 AXD 2 AXD 3 SCD 1 SCD 2 RM-15 CM-60

SPD 1 SPD 2 SPD 3 ACD 1 ACD 2

3 3 3 3 3

3

6

3

3

6

3

3

3

6

3

3

6

3

3

3

6

3

3

6

3

3

6

3

1 (*)

3

3

6

3

6

6

12

6

1

1

1

1

1

1

1

1

2

1

3

3

6

3

1

1 1 1

1 1

1

1

1

1 1

2

1

2

1

2

1

2

1

1

2

1

1

1

1

3

1

1

3

1

1

3

1

3

1 1 1

1 1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Overview of FAGOR subsidiaries:

SPAIN

Headquarters:

FAGOR AUTOMATION S.COOP.

Bº San Andrés s/n, Apdo. 144

E-20500 ARRASATE-MONDRAGON www.fagorautomation.mcc.es

[email protected]

Tel: 34-943-719200

Fax: 34-943-791712

34-943-771118 (Service Dept.)

Usurbil:

FAGOR AUTOMATION S.COOP.

Planta Usurbil

San Esteban s/n Txoko-Alde

20170 USURBIL

Tel: 34-943-366332

Fax: 34-943-360527 [email protected]

Barcelona:

FAGOR AUTOMATION, Catalunya

Pg. Ferrocarrils Catalans,

117-119 1ª Pl. Local 12

CORNELLÀ DE LLOBREGAT

08940 BARCELONA

Tel.: 34-93-4744375

Fax: 34-93-4744327 [email protected]

FRANCE

AUTOMATION SYSTÈMES

Parc Technologique de La Pardieu

16 Rue Patrick Depailler

63000 CLERMONT FERRAND

Tel.: 33-473277916

Fax: 33-473150289

E-mail: [email protected]

GERMANY

FAGOR INDUSTRIECOMMERZ GMBH

Postfach 604 D-73006 GÖPPINGEN

Nördliche Ringstrasse, 100

D-73033 GÖPPINGEN

Tel.: 49-716120040

Fax: 49-716113327

E-mail: [email protected]

ITALY

FAGOR ITALIA S.R.L.

Centro Direzionale Lombardo

Pal. CD3 P.T. - Via Roma, 108

20060 CASSINA DE PECCHI (MI)

Tel.: 39-0295301290

Fax: 39-0295301298

E-mail: [email protected]

UNITED KINGDOM

FAGOR AUTOMATION UK Ltd.

Unit T4, Dudley Court North

Waterfront East

Level Street, Brierley Hill

West Midlands DY5 2HU.

Tel: 44-1384 572550

Fax: 44-1384 572025

Cellular phone: 44-836 653 701 [email protected]

SWITZERLAND

FAGOR AUTOMATION SUISSE S.à r.l.

Rue B.- Vuilleumier 11

CH-2616 RENAN (BE)

Tel.: 41-329631863

Fax: 41-329631864

E-mail: [email protected]

PORTUGAL

FAGOR AUTOMATION LTDA.

Sucursal Portuguesa

Rua Gonçalves Zarco nº 1129-B-2º

Salas 210/212

4450 LEÇA DA PALMEIRA

Tel : 351 22 996 88 65

Fax: 351 22 996 07 19 [email protected]

USA

Chicago:

FAGOR AUTOMATION CORP.

2250 Estes Avenue

ELK GROVE VILLAGE, IL 60007

Tel: 1-847-9811500

1-847-9811595 (Service)

Fax: 1-847-9811311 [email protected]

Tlx: 285273

California:

FAGOR AUTOMATION West Coast

3176 Pullman Suite 110

Costa Mesa CA 92626

Tel: 1-714-9579885/9892

Fax: 1-714-9579891 [email protected]

New Jersey:

FAGOR AUTOMATION East Coast

Tel: 1-973-7733525

Fax: 1-973-7733526 [email protected]

CANADA

Ontario:

FAGOR AUTOMATION ONTARIO

Unit 3, 6380 Tomken Road

MISSISSAUGA L5T 1Y4

Tel: 1-905-6707448

Fax: 1-905-6707449 [email protected]

[email protected]

Montreal:

FAGOR AUTOMATION QUEBEC

Tel.: 1-450-2270588

Fax: 1-450-2276132

Cellular phone: 1-450-9517160

E-mail: [email protected]

BRAZIL

FAGOR AUTOMATION DO BRASIL

COM.IMP. E EXPORTAÇAO LTDA.

Rua Säo Sebastião 825

CEP 04708-001

SAO PAULO-SP

Tel.: 55-11-51841414

Fax: 55-11-51819898 [email protected]

CHINA, P.R.

Beijing:

Beijing FAGOR AUTOMATION Equipment

Co.,Ltd.

Room No. B-202, Guo Men Building, Nº 1

ZuoJiaZhuang, Chaoyang District

BEIJING 100028

Tel: 86-10-6464 1951/1952/1953

Fax: 86-10-6464 1954 [email protected]

Shanghai:

Beijing FAGOR AUTOMATION Equipment

Ltd., Nanjing Office

Holiday Inn (Nanjing)

45 North Zhong Shan Road Nanjing

210008, Jiangsu Provence, P.R.China

Tel: 86-25-3328259

Fax: 86-25-3328260 [email protected]

Guangzhou:

Beijing FAGOR AUTOMATION Equipment

Co.Ltd., Guangzhou Rep.Office

No. 423, Plotio Plaza.

No. 18 Airport Road, Baiyun district

GUANGZHOU 510405

Tel: 86-20-86553124

86-20-86577228 Ext. 2423

Fax: 86-20-86553124 [email protected]

HONG KONG

FAGOR AUTOMATION (ASIA) LTD.

M4, Sunbeam Centre

27 Shing Yip St. Kwun Tong

KOWLOON, HONG KONG

Tel: 852-23891663

Fax: 852-23895086 [email protected]

KOREA,Republic of

FAGOR AUTOMATION KOREA, LTD.

304 Bomi Bldg., 661 Deungchon-Dong

Kangseo-Ku, Seoul 157-030, Korea

Tel: 82-2-36652923/4

Fax: 82-2-36652925 [email protected]

TAIWAN R.O.C.

FAGOR AUTOMATION (ASIA) LTD.,TWN

BRANCH (H.K.)

11F-2 No.61, SEC.2, KUNG YI ROAD

TAICHUNG, TAIWAN R.O.C.

Tel: 886-4-3271282

Fax: 886-4-3271283 [email protected]

[email protected]

SINGAPORE

FAGOR AUTOMATION (S) PTE.LTD.

240 MacPherson Road

03-01 Pines Industrial Building

SINGAPORE 348574

Tel: 65-8417345/8417346

Fax: 65-8417348 [email protected]

C - 12 References Ver. 0002

APPENDIX D:

COMPATIBILITY

Compatibility Ver. 0002 D - 1

1.

MAINS VOLTAGE: 380 - 460

Originally, the drives and power supplies were designed for a mains voltage of 380 Vac,

50Hz/60Hz. They have now been redesigned to work with mains voltage ranging between

380 Vac and 460 Vac at 50Hz/60 Hz.

They are identified as:

Elements for 380 Vac

Fagor Automation,

S.Coop.(Spain)

MODEL

INPUT

P S - 2 5

3 x 3 8 0 V a c 5 0 / 6 0 H z

OUTPUT 6 0 0 V d c 4 5 A

Elements for 380-460 Vac

Fagor Automation,

S.Coop.(Spain)

MODEL

INPUT

P S - 2 5 A

3 x 3 8 0 ÷ 4 6 0 V a c 5 0 / 6 0 H z

OUTPUT 5 3 7 - 6 5 0 V d c 4 5 A

Fagor Automation,

S.Coop.(Spain)

MODEL

INPUT

A X D 1 . 1 5 - A 1 - 1

6 0 0 - 8 0 0 V d c

OUTPUT 3 x 3 8 0 V a c 7 A 0 - 8 0 0 H z

Fagor Automation,

S.Coop.(Spain)

MODEL A X D 1 . 1 5 - A 1 - 1

INPUT

OUTPUT

4 5 6 - 8 0 0 V d c

3 x 0 ÷ 4 6 0 V a c 7 A

0 - 8 0 0 H z

Compatibility:

The elements ready for mains voltage between 380 Vac and 460 Vac:

- Drive (version MSC 12A and later),

- Auxiliary power supply "APS 24" (version PF 05A and later) ,

- Capacitor module "CM-602" (version 01A and later) and

- Mains Filters EMK are compatible with all the "PS" and "XPS" power supplies.

The elements ready for a mains voltage of 380 Vac:

- Drive (version MSC 11A and older),

- Auxiliary power supply "APS 24" (version PF 04A and older),

- Capacitor module "CM-60" (version 00A) and

- Mains Filters Power-Pro are not compatible with "PS-xxA" and "XPS" power supplies.

D - 2 Compatibility Ver. 0002

Replacing a 380 Vac module with a 460Vac module:

New drive "MSC 12A".

New capacitor module "01A".

New Auxiliary Power Supply APS 24 "PF 05A".

They may be incorporated into any servo drive system regardless of its power supply.

New power supply "PS-xxA".

If the system includes any element for a mains voltage of 380 Vac:

An "MSC 11A" drive, or an APS 24 power supply "PF 04A", or a Capacitor module

CM-60 "00A" it needs a "PS-xx" power supply.

(the "PS-xx" is nothing but a "PS-xxA" factory limited to work at 380 Vac)

It will take a mains voltage limited to 380 Vac.

Obviously, if the system includes only "MSC 12A" drives, there is no problem.

It will take a mains voltage range of 380-460 Vac.

New Power Supply PS-25B.

If the system includes an element for a Mains voltage of 380 Vac: an "MSC 11A" drive or a Capacitor module CM-60 "00A", the PS-25B must be set up to work at 380 Vac.

It will admit a Mains voltage limited to 380 Vac.

Note: The new Compact Drives (version MSC 05A and later) are designed to also run at 380-

460 Vac but they have no compatibility problems with previous equipment.

2.

VECON BOARD 03A - SOFTWARE 03.03

The new Vecon board version (03A) expands the capacity of its Flash memory and improves the Flash and RAM memory speed.

This improved Vecon board is related to software version v03.03.

This board (VEC 03A) is incompatible with software version 03.02 and older.

However, the software version 03.03 is compatible with Vecon board versions older than VEC

03A.

3.

03A VECON BOARD - SOFTWARE MC+PLC

Software version v04.01 includes the options of Motion control (MC) and PLC.

This v04.01 option is compatible with Vecon boards with versions older than VEC 03A, but:

The Motion Control (MC) and PLC implemented in version v04.01 require a Vecon board version VEC 03A.

Compatibility Ver. 0002 D - 3

User notes:

D - 4 Compatibility Ver. 0002

APPENDIX E:

PROTECTIONS

ON DRIVES AND MOTORS

E - 1 Protections

Ver: 0002

PROTECTIONS AGAINST OVERCURRENT AND

OVERTEMPERATURE ON DRIVES AND MOTORS

This document describes the various limitations and monitoring that the drive carries out to protect the servo system against excessive temperature and current.

1.

PROTECTIONS OF THE DRIVE

The elements setting the current limit through the drive are the power semiconductors IGBTs.

The range of Fagor drives carry IGBTs whose maximum current (I

IGBT

) ranges between 8A and 150A as shown in the table below.

A X D , S P D ,

A C D , S C D

I

I G B T

1 .

0 8 1 .

1 5 1 .

2 5 1 .

3 5

8 1 5 2 5 3 5

2 .

5 0

5 0

2 .

7 5

7 5

3 .

1 0 -

0

3 .

1 5 -

0

1 0 0 1 5 0

The IGBTs of the drive may be damaged if:

- The current exceeds the permitted peak value. To prevent this, the drive limits the current command it will attend to (i command section 1.1 in this Appendix.

) and watches the real instantaneous current (i real

). See

- The drive works with over-demanding duty cycles that cause the rms current to exceed the maximum permitted. This causes the IGBTs to overhear. To prevent this, there are two protections:

- Some thermal sensors located on the heat-sink watch the actual temperature of these power semiconductors. See section 1.2.

- The drive estimates this rms current with the integral of the I 2 t product. This gives an estimate of the temperature of the IGBTs. See section 1.3.

E - 2 Protections Ver: 0002

1.1

PEAK CURRENT LIMIT AT THE DRIVE

The operator may adjust the value of parameter CP20 -F00307- to limit the current command.

This way, the drive will never attend to current commands exceeding the I peak

.

Parameter setting:

CP20 < i peak

Bear in mind that:

Ipeak

=

I

IGBT

Ipeak

=

I

IGBT

2 on synchronous motors on asynchronous motors

Monitoring: if (I real

> k * I

IGBT

) => the current will be temporarily cut off where the value of k is: 1.5 on synchronous motors

1.33 on asynchronous motors.

When exceeding this limit, the drive will cut off the current and when the current returns below this limit, it will be activated back. Working in this area will cause undesired current oscillations.

If (I real

> 1.6 * I

IGBT

) => it will issue error 212

Exceeding this limit would damage the IGBTs.

1.2

TEMPERATURE SENSORS ON THE HEAT-SINK.

There is a temperature sensor (gage) on the drive's heat-sink.

KV10 -F01102- variable provides information about this temperature.

KV10 (F01102)

Function:

Units:

CoolingTemperature

Reading of the heat-sink temperature of the module

Tenths of degree Centigrade

Protections

Ver: 0002

E - 3

1.3

PERMANENT DUTY CYCLES ALLOWED TO THE DRIVE,

CALCULATING THE I2T PRODUCT.

Chapter EM indicates which is the maximum current allowed for permanent duty cycles (S1).

The higher the ambient temperature, the lower the capabilities of the drive. Thus, the operator must decrease the demands in the duty cycles. This effect of the temperature is called "power

Derating".

The graphs below include two examples of Derating. The duty cycle S1 means a constant load that brings the system to its maximum temperature.

S1 DUTY CYCLE according to the

IEC 34-1

50

45

Current

S1 (Amp)

AXD 3.100

t

Tmax

(thermal equilibrium) t

45 (113) 55 (131) °C (°F)

53

43

Current

S1 (Amp)

SPD 2.75

35 (95) 55 (131) °C (°F)

The drive estimates the temperature of the IGBTs based on the rms current circulating through them.

The following equation calculates the rms current: Irms

= t +

∫ t

τ i

2

( ) ( )

This temperature estimate is based on the calculation we call I 2 t.

If this temperature exceeds a predetermined value, error 202 will be activated Drive overload.

For a system with some particular IGBTs, the drive allows rms currents (estimated by calculating the I 2 t) of:

Irms

= ⋅

IGBT for synchronous motors.

Irms

=

I

IGBT

2 for asynchronous motors.

E - 4 Protections Ver: 0002

Calculating the I 2 t implies an ambient temperature of 40°C (104°F). For temperatures of up to

55°C (131°F) (the maximum allowed) and since the driver does not know the actual ambient temperature, this protection may not be sufficient. In this case and if the operator would use a cycle which would exceed the derating, it could damage the drive.

As soon as it is possible to vary the frequency of the PWM, the maximum limit of the I 2 t allowed it will adapt automatically in order to consider the losses in the commutations corresponding to each frequency.

Equivalent duty cycles.

These drives will also admit any other equivalent duty cycle whose rms current is the one permitted in its derating graph.

The graph below shows an example of two equivalent duty cycles. The integral of the I 2 t is the same in both cases even when the integral of the It product is greater in the first case (a).

Ip

In

Current a b

Time

T T

Protections

Ver: 0002

E - 5

E - 6

Typical cycle of the drive for synchronous motors.

The synchronous drive withstands, for example, cycles equivalent to this one:

2·In

In

Current

Time

Irms =

(

2 In

)

10

+ In2

9.5

10

0.5 sec 10 sec

Where In is the rated current which is the following for each drive (in Amps):

AXD, ACD

In

Ipeak

1.08

4

8

1.15

7.5

15

1.25

12.5

25

1.35

17.5

35

2.50

25

50

2.75

37.5

75

3.100

3.150

50

100

75

150

Ipeak

=

I

IGBT

As long as the IGBTs are below their rated working temperature (for example, on start-up) they will be allowed some more demanding initial cycles.

Typical cycle of the drive for asynchronous motors.

The asynchronous drive withstands indefinitely cycles equivalent to their rated current In, which is also the maximum it can offer (that is: I peak

=In). The maximum current limit is sufficient to protect the asynchronous drives and, consequently, do not need the calculation of the I 2 t.

Current

Ipeak = In = I

IGBT

/ sqr(2)

Time

Where In is the rated current which is the following for each drive (in Amps):

AXD, ACD

Ipeak = In

1.08

5.6

1.15

10.6

1.25

19.6

1.35

28.5

2.50

35.4

2.75

53

3.100

3.150

80 106

Protections Ver: 0002

2.

PROTECTIONS OF THE MOTOR

The mechanical power limit of a motor is determined, among other causes, by the maximum temperature allowed in its windings and, in motors with permanent magnets, by the conservation of its magnetic properties.

As with the protection of the drives, the protection of the motors is watched in three modes at the same time:

- Watch that the current does not exceed the maximum peak value permitted. To prevent this, the drive limits the current command which it will attend to (i command the real instantaneous current (i real

). See section 2.1.

- In permanent duty cycles, the motor temperature is monitored—

) and it watches

- by thermal sensors located in the motor. See section 2.2.

- by estimating the rms current based on the integral of the I 2 t product. This offers a temperature estimate. See section 2.3.

2.1

PEAK CURRENT LIMIT AT THE MOTOR.

The operator may adjust the value of its parameter CP20 -F00307- to limit the current command. Thus, the drive will never attend to current commands exceeding MP4 -S00109-, which is the maximum peak current allowed at the motor.

That maximum peak current MP4 -S00109- is the one shown in the table of section SM.2 of the general manual. This data is not related to any duty cycle (S3 or S6). It only sets a preventive current limit to avoid demagnetizing the motor.

CP20 < MP4

MP4 -S00109- is a parameter for synchronous motors only.

In asynchronous motors, the current command is not monitored.

2.2

TEMPERATURE SENSORS IN THE MOTOR.

The motors have an overtemperature sensor (gage) PTC.

It is a triple sensor which permits detecting overtemperatures in the windings of each phase.

This sensor is connected to the drive through the feedback cable of the motor itself. Error 108 will be issued when the limit temperature for the motor is reached (which in Class F is 150°C

(302°F)).

The asynchronous motor also has a thermal Klixon switch that opens when those 150°C are reached. This switch must be included in the emergency chain of the electrical cabinet.

Protections

Ver: 0002

E - 7

2.3

PERMANENT DUTY CYCLES ALLOWED FOR THE MOTOR,

CALCULATING THE I2T PRODUCT.

The drive software offers a procedure to calculate the integral of I 2 t applied to both the synchronous and asynchronous motors.

The permanent watch of the I 2 t product tolerates any equivalent duty cycle producing a maximum temperature equal to the one produced in the S1 cycle with a time constant set by parameter MP13 -F01209- MotorThermalTimeConstant

However, the overheating caused by very high peak currents cannot be modelled with the I 2 t calculation. In this case, the temperature sensors of the motors will be the ones detecting the overheating.

Synchronous Motors

The table of chapter SM indicates the rated currents and the maximum peak currents at the motors.

Asynchronous Motors

The table of chapter AM describes the maximum currents through the motor in the S1 and S6 duty cycles. When increasing the ambient temperature and the altitude, the operator must decrease the demand on the requested cycles.

DUTY CYCLES according to the

IEC 34-1 standard

S1 cycle

Nominal in S1

Load

Temperature

Θ max in thermal balance

S6 cycle -40% 10 min

Load R F

Temperature

Losses

R/F=4/6

Θ

R: Rated in S6-40%

F: Free (no load) max

E - 8 Protections Ver: 0002

3.

EXTERNAL MONITORING OF THE REAL I

2

T

LEVELS.

The user may know the effort level of the drive by checking the value of the I 2 t product through the variable: realvalue: KV32 -F01109- I2tDrive

The user may know the effort level of the motor by checking the value of the I 2 t product through the variable: realvalue: KV36 -F01111- I2tMotor

These values are given as "percentage used over the maximum". In software versions prior to

V04.01 the units were absolute and it used two more parameters.

To determine whether a duty cycle demands a bearable degree of effort indefinitely from the servo system (drive+motor), it has to be brought to the rated running temperature and then execute that cycle.

By editing these variables: KV32 -F01109- and KV36 -F01111-, it is possible to simulate an

"increase" of the temperature of the servo. Later, execute a test cycle. The I 2 t calculation will determine whether the servo system withstands or not that particular cycle.

The oscilloscope integrated into the WinDDSSetup may be used to display the KV32 -F01109and KV36 -F01111- variables during the cycle being analyzed. Then, calculate the I 2 t product over the graph and determine whether the servo system can withstand it or not.

Protections

Ver: 0002

E - 9

4.

PROTECTION OF THE EXTERNAL BALLAST

RESISTOR

From software version 03.07 on, the Drive internally calculates the i 2 t to protect the Ballast resistor of the Compact Modules (ACD and SCD).

If the Compact Module uses an External Ballast Resistor:

The Drive must know the electrical specifications of that external resistor through the following parameters:

KP2 O

Function:

Valid values:

KP3 O

Function:

Valid values:

KP4 O

Function:

Valid values:

KV40

Function:

(F1113) ExtBallastResistance

It contains the ohm value of the External Ballast Resistor on a Compact Drive.

0..6K5 (0 by default)

(F1114) ExtBallastPower

It contains the power value of the External Ballast Resistor on a Compact Drive.

0..65 kw (0 by default)

(F1116) ExtBallastEnergyPulse

It contains the value of the energy pulse that can be dissipated through the External

Ballast Resistor on a Compact Drive.

0..65 kWs (0 by default)

(F1115) ExtBallastOverload

It shows the % of overload on the External Ballast resistor for a Compact Drive. A value greater than 100% at this variable will trigger error message 301.

If the Compact Module DOES NOT use an External Ballast Resistor:

The software knows the specifications of the resistors of each Compact Drive model and monitors the i 2 t on its own.

Important: If any of the KP2, KP3 or KP4 parameters is set to "0", the i 2 t protection will be carried out according to the characteristics of the internal resistors of the modules.

Important: If all three parameters KP2, KP3 and KP4 are set to "65535" the i 2 t protection will be disabled.

E - 10 Protections Ver: 0002

5.

PROTECTION AGAINST A MAINS PHASE DROP

From drive software version 03.07 on and with MSC board version 06A or later, the Compact

Modules (ACD and SCD) monitor the presence of all three mains phases.

Should any of them drop for over 10 msecs, Error 3 will be triggered.

Protections

Ver: 0002

E - 11

User notes:

E - 12 Protections Ver: 0002

advertisement

Key Features

  • Permanent magnets (SmCo)
  • High torque density
  • Brushless
  • High reliability
  • Low maintenance
  • Optional fan-cooled

Frequently Answers and Questions

What type of magnets are used in FXM motors?
FXM motors use permanent rare earth magnets (SmCo).
What is the protection level of FXM motors?
The standard protection level is IP64, with an optional IP65 level available with a fan.
What types of feedback are available for FXM motors?
FXM motors can have either a sine-wave encoder or a resolver feedback.
What is the function of the temperature sensor in FXM motors?
The temperature sensor monitors the internal temperature of the motor.
Are FXM motors suitable for applications requiring high positioning accuracy?
Yes, FXM motors are designed to meet the requirements of applications requiring high positioning accuracy.

Related manuals