Comtech EF Data LBC-4000 L-band Converter Installation and Operation Manual
Below you will find brief information for L-band Converter LBC-4000. This manual provides instructions for installation and operation of the L-band Up/Down Converter System.
PDF
Download
Document
Advertisement
Advertisement
LBC-4000 L-Band Up/Down Converter System with Ethernet Installation and Operation Manual IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifications are subject to change without prior notice. Part Number MN-LBC4000A Revision 2 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation and Operation Manual Part Number MN-LBC4000A Revision 2 Copyright © 2013 Comtech EF Data. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161 This page is intentionally blank. ii TABLE OF CONTENTS TABLE OF CONTENTS .............................................................................................................. III TABLES .................................................................................................................................... VIII FIGURES .................................................................................................................................. VIII PREFACE ................................................................................................................................... IX About this Manual .............................................................................................................................. ix Reporting Comments or Suggestions Concerning this Manual ............................................................... ix Conventions and References ............................................................................................................... ix Patents and Trademarks .......................................................................................................................... ix Warnings, Cautions, and Notes ................................................................................................................ ix Examples of Multi‐Hazard Notices ............................................................................................................ x Recommended Standard Designations ..................................................................................................... x Metric Conversion ..................................................................................................................................... x Safety and Compliance ......................................................................................................................... x Electrical Safety and Compliance .............................................................................................................. x Electrical Installation ................................................................................................................................. x Operating Environment ........................................................................................................................... xi European Union Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive (1999/5/EC) and EN 301 489‐1 .............................................................................................. xi European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EC) ......................... xi European Union Low Voltage Directive (LVD) (2006/95/EC) .............................................................. xii European Union RoHS Directive (2002/95/EC) ................................................................................... xii European Union Telecommunications Terminal Equipment Directive (91/263/EEC) ........................ xii CE Mark ...............................................................................................................................................xiii Warranty Policy ................................................................................................................................. xiii Limitations of Warranty ..........................................................................................................................xiii Exclusive Remedies ................................................................................................................................. xiv Getting Help ....................................................................................................................................... xv Contacting Comtech EF Data .................................................................................................................. xv Returning a Product for Upgrade or Repair ............................................................................................ xvi CHAPTER 1. INTRODUCTION ............................................................................................. 1–1 1.1 Overview .............................................................................................................................. 1–1 1.2 Features ............................................................................................................................... 1–1 iii LBC-4000 L-Band Up/Down Converter System with Ethernet Table of Contents 1.2.1 1.3 Revision 2 MN-LBC4000A Dimensional Envelope ........................................................................................................... 1–3 Functional Description .......................................................................................................... 1–4 1.4 Summary of Specifications .................................................................................................... 1–5 1.4.1 Physical & Environmental ..................................................................................................... 1–5 1.4.2 Prime Power .......................................................................................................................... 1–5 1.4.3 External Reference ................................................................................................................ 1–5 1.4.4 Monitor & Control ................................................................................................................. 1–5 1.4.5 LBC‐4000 L‐Band Downconverter IDU .................................................................................. 1–6 1.4.6 LBC‐4000 L‐Band Upconverter IDU ....................................................................................... 1–7 CHAPTER 2. INSTALLATION .............................................................................................. 2–1 2.1 Unpacking and Inspecting the Shipment ............................................................................... 2–1 2.2 Installing Into a Rack Enclosure ............................................................................................. 2–2 2.2.1 Installing the Optional Rear‐Mounting Support Brackets Kit ............................................... 2–4 2.2.2 Installing the Optional Side‐Mounting Bearingless Rack Slide Set ....................................... 2–6 2.3 Connecting the Prime Power ................................................................................................ 2–7 2.4 Connecting External Cables ................................................................................................... 2–7 2.5 Removing or Installing Converter Modules ........................................................................... 2–7 CHAPTER 3. REAR PANEL CONNECTIONS ...................................................................... 3–1 3.1 Cabling Connection Types ..................................................................................................... 3–1 3.1.1 Coaxial Cable Connections .................................................................................................... 3–1 3.1.1.1 Type ‘BNC’ ......................................................................................................................... 3–2 3.1.1.2 Type ‘TNC’ ......................................................................................................................... 3–2 3.1.1.3 Type ‘N’ ............................................................................................................................. 3–2 3.1.1.4 Type ‘F’ .............................................................................................................................. 3–3 3.1.1.5 Type ‘SMA’ (Subminiature Version ‘A’) ............................................................................. 3–3 3.1.2 D‐Subminiature Cable Connections ...................................................................................... 3–3 3.1.3 Circular Cable Connections ................................................................................................... 3–4 3.1.4 RJ‐45, RJ‐48 Cable Connections ............................................................................................ 3–4 3.2 LBC‐4000 Cabling Connections ............................................................................................. 3–5 3.2.1 RF/IF Connectors ................................................................................................................... 3–6 3.2.1.1 J4 | RF OUT/IN Unit B Connector (Type ‘N’ Female) ........................................................ 3–6 3.2.1.2 J5 | IF IN/OUT Unit B Connector (Type ‘BNC’ Female) .................................................... 3–6 3.2.1.3 J6 | RF OUT/IN Unit A Connector (Type ‘N’ Female) ........................................................ 3–6 3.2.1.4 J7 | IF IN/OUT Unit A Connector (Type ‘BNC’ Female) ..................................................... 3–6 3.2.2 Utility Connectors ................................................................................................................. 3–7 3.2.2.1 J2 | EXT REF (External Reference) Input Connector (Type ‘BNC’ Female) ........................ 3–7 3.2.2.2 10/100 Ethernet Connector (RJ‐45) .................................................................................. 3–7 iv LBC-4000 L-Band Up/Down Converter System with Ethernet Table of Contents Revision 2 MN-LBC4000A 3.2.2.3 P1 | RELAY (Summary Fault Output) Connector (DB‐9F) .................................................. 3–8 3.2.2.4 J1 | COM1 (EIA‐485/232 Interface) Connector (DB‐9F) .................................................... 3–9 3.2.3 Optional 1:1 Redundancy Connectors ................................................................................ 3–10 3.2.3.1 Optional IF Connectors (Type ‘BNC’ Female) .................................................................. 3–10 3.2.3.2 Optional RF Connectors (Type ‘SMA’ Female) ................................................................ 3–10 3.3 LBC‐4000 Ground and Power Connections .......................................................................... 3–10 3.3.1 Chassis Ground Interface .................................................................................................... 3–11 3.3.2 Chassis Power Interfaces .................................................................................................... 3–11 3.3.2.1 AC Prime Power Connector ............................................................................................. 3–11 3.3.2.2 DC Filter Input Module .................................................................................................... 3–11 3.3.2.3 Applying Power to the LBC‐4000 .................................................................................... 3–12 CHAPTER 4. UPDATING FIRMWARE ................................................................................. 4–1 4.1 Updating Firmware via the Internet ...................................................................................... 4–1 4.2 Getting Started: Preparing for the Firmware Download ........................................................ 4–2 4.3 Downloading and Extracting the Firmware Update ............................................................... 4–6 4.4 Performing the Ethernet FTP Upload Procedure .................................................................... 4–8 CHAPTER 5. FRONT PANEL OPERATION ......................................................................... 5–1 5.1 Introduction ......................................................................................................................... 5–1 5.1.1 Energizing the LBC‐4000 ....................................................................................................... 5–2 5.1.2 CONV A and CONV B LED Indicators ..................................................................................... 5–2 5.1.3 Keypad ................................................................................................................................... 5–3 5.1.4 Vacuum Fluorescent Display (VFD) ....................................................................................... 5–4 5.1.4.1 Opening Screen ................................................................................................................. 5–4 5.1.4.2 Screen Saver ...................................................................................................................... 5–4 5.2 Top‐level (Main) Menu ......................................................................................................... 5–5 5.2.1 CONFIG (CONFIGURATION) ................................................................................................... 5–6 5.2.1.1 CONFIG: CONV‐A or CONV‐B (Converter Unit A or Unit B) ............................................... 5–7 5.2.1.2 CONFIG: REMOTE (Remote Control) ................................................................................. 5–8 5.2.1.3 CONFIG: REDUND (Redundancy) .................................................................................... 5–11 5.2.1.4 CONFIG: REFADJ (Reference Oscillator Adjustment) ...................................................... 5–12 5.2.1.5 CONFIG: SPECT‐INV (Spectrum Inversion) ...................................................................... 5–12 5.2.2 MONITOR ............................................................................................................................ 5–13 5.2.3 FAULTS ................................................................................................................................ 5–14 5.2.3.1 FAULTS: CURRENT ........................................................................................................... 5–14 5.2.3.2 FAULTS: STORED ............................................................................................................. 5–14 5.2.4 UTILITY ................................................................................................................................ 5–15 5.2.4.1 UTILITY: TIME .................................................................................................................. 5–16 5.2.4.2 UTILITY: DISP (Display Brightness) .................................................................................. 5–16 5.2.4.3 UTILITY: FIRMWARE ........................................................................................................ 5–16 v LBC-4000 L-Band Up/Down Converter System with Ethernet Table of Contents 5.2.4.4 5.2.4.5 5.2.4.6 5.2.4.7 Revision 2 MN-LBC4000A UTILITY: AID (Application ID) ........................................................................................... 5–17 UTILITY: LAMP‐TEST (Front Panel LED Test) .................................................................... 5–18 UTILITY: Relay .................................................................................................................. 5–18 UTILITY: SCRSAVER .......................................................................................................... 5–18 CHAPTER 6. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT ......................... 6–1 6.1 Introduction ......................................................................................................................... 6–1 6.1.1 Ethernet Management Interface Protocols .......................................................................... 6–2 6.2 SNMP Interface .................................................................................................................... 6–3 6.2.1 Management Information Base (MIB) Files .......................................................................... 6–3 6.2.2 SNMP Community Strings ..................................................................................................... 6–3 6.2.3 SNMP Traps ........................................................................................................................... 6–4 6.3 Telnet Interface .................................................................................................................... 6–5 6.3.1 Telnet Operation via HyperTerminal .................................................................................... 6–5 6.4 Web Server (HTTP) Interface ................................................................................................. 6–7 6.4.1 Enabling the Web Server Interface ....................................................................................... 6–7 6.4.2 User Login ............................................................................................................................. 6–8 6.4.3 Web Server Interface – Operational Features ...................................................................... 6–9 6.4.3.1 Navigation ......................................................................................................................... 6–9 6.4.3.2 Page Sections .................................................................................................................... 6–9 6.4.3.3 Execution Buttons ............................................................................................................. 6–9 6.4.3.4 Feature Selection ............................................................................................................ 6–10 6.4.3.5 Text or Data Entry ........................................................................................................... 6–10 6.4.4 Web Server Interface – Menu Tree ..................................................................................... 6–10 6.4.5 Web Server Interface – Page Descriptions ......................................................................... 6–11 6.4.5.1 Home Pages .................................................................................................................... 6–11 6.4.5.1.1 Home | Home ........................................................................................................... 6–11 6.4.5.1.2 Home | Contact ........................................................................................................ 6–12 6.4.5.1.3 Home | Support ........................................................................................................ 6–13 6.4.5.2 Admin Pages .................................................................................................................... 6–14 6.4.5.2.1 Admin | Access ......................................................................................................... 6–14 6.4.5.2.2 Admin | SNMP .......................................................................................................... 6–16 6.4.5.3 Config Pages .................................................................................................................... 6–18 6.4.5.3.1 Config | ConvA / Conv B ........................................................................................... 6–18 6.4.5.3.2 Config | Ref ............................................................................................................... 6–20 6.4.5.3.3 Config | Utility ........................................................................................................... 6–21 6.4.5.3.4 Config | Redundancy ................................................................................................ 6–22 6.4.5.3.5 Config | Serial ........................................................................................................... 6–23 6.4.5.4 Status Pages .................................................................................................................... 6–24 6.4.5.4.1 Status | Summary ..................................................................................................... 6–24 6.4.5.4.2 Status | Faults ........................................................................................................... 6–26 vi LBC-4000 L-Band Up/Down Converter System with Ethernet Table of Contents Revision 2 MN-LBC4000A CHAPTER 7. SERIAL-BASED REMOTE PRODUCT MANAGEMENT................................ 7–1 7.1 Introduction ......................................................................................................................... 7–1 7.1.1 EIA‐485 .................................................................................................................................. 7–2 7.1.2 EIA‐232 .................................................................................................................................. 7–2 7.2 Remote Commands and Queries Overview ........................................................................... 7–3 7.2.1 Basic Protocol ........................................................................................................................ 7–3 7.2.2 Packet Structure .................................................................................................................... 7–3 7.2.2.1 Start of Packet ................................................................................................................... 7–4 7.2.2.2 Target Address .................................................................................................................. 7–5 7.2.2.3 Address Delimiter .............................................................................................................. 7–5 7.2.2.4 Instruction Code ................................................................................................................ 7–5 7.2.2.5 Instruction Code Qualifier ................................................................................................. 7–6 7.2.2.6 Optional Message Arguments ........................................................................................... 7–7 7.2.2.7 End of Packet .................................................................................................................... 7–7 7.3 Remote Commands and Queries ........................................................................................... 7–8 APPENDIX A. UP/DOWNCONVERTER IDU MODULE REMOVAL/RE-INSTALLATION . A–1 A.1 Introduction ......................................................................................................................... A–1 A.2 IDU Module Removal Procedure ........................................................................................... A–2 A.3 IDU Module Installation Procedure ....................................................................................... A–5 APPENDIX B. LBC-4000 REDUNDANCY OPERATION ..................................................... B–1 B.1 Introduction ......................................................................................................................... B–1 B.2 Redundancy Operations Overview ........................................................................................ B–1 B.3 Redundancy Operations via the LBC‐4000 Front Panel .......................................................... B–3 B.3.1 Main Menu ............................................................................................................................ B–4 B.3.2 CONFIG (Configuration) Menu .............................................................................................. B–5 B.3.3 CONFIG: REDUND (Redundancy) .......................................................................................... B–6 B.3.4 Gain Offset for Redundant Operations ................................................................................. B–7 B.4 Redundancy Operations via the LBC‐4000 Web Server Interface ........................................... B–8 B.5 Redundancy Operations via Serial Remote Control ............................................................... B–9 vii LBC-4000 L-Band Up/Down Converter System with Ethernet Table of Contents Revision 2 MN-LBC4000A TABLES Table 3-1. LBC-4000 Connectors ............................................................................................................. 3–5 Table 3-2. P1 | RELAY Connector Pinouts ............................................................................................... 3–8 Table 3-3. J1 | COM1 2-Wire EIA-485 Interface Connector Pinouts ........................................................ 3–9 Table 3-4. J1 | COM1 4-Wire EIA-485 Interface Connector Pinouts ........................................................ 3–9 Table 3-5. J1 | COM1 EIA-232 Interface Connector Pinouts .................................................................... 3–9 Table 3-6. DC Input Filter Module Pinouts .............................................................................................. 3–11 FIGURES Figure 1‐1. Comtech EF Data LBC‐4000 L‐Band Up/Down Converter With Ethernet ............................... 1–1 Figure 1‐2. LBC‐4000 Front and Rear Panels (Redundant Unit Shown) .................................................... 1–2 Figure 1‐3. LBC‐4000 Dimensional Envelope ............................................................................................ 1–3 Figure 1‐4. LBC‐4000 Typical Application Block Diagram ......................................................................... 1–4 Figure 2‐1. Unpacking and Inspecting the LBC‐4000 ................................................................................ 2–1 Figure 2‐2. Installing into a Rack Enclosure .............................................................................................. 2–3 Figure 2‐3. Installing the Optional Rear‐Mounting Support Brackets Kit ................................................ 2–4 Figure 2‐4. Installing the Optional Side‐Mounting Bearingless Rack Slide Set ........................................ 2–6 Figure 3‐1. Coaxial Connector Examples ................................................................................................... 3–1 Figure 3‐2. D‐Subminiature Connector Examples ..................................................................................... 3–3 Figure 3‐3. LBC‐4000 Rear Panel Connectors (Redundancy Unit Shown) ................................................ 3–5 Figure 3‐4. LBC‐4000 Ground and Power Interfaces .............................................................................. 3–10 Figure 5‐1. LBC‐4000 Front Panel ............................................................................................................. 5–1 Figure 5‐2. LBC‐4000 Front Panel Menu Tree ........................................................................................... 5–5 Figure 6‐1. Home | Home page .............................................................................................................. 6–11 Figure 6‐2. Home | Contact page ............................................................................................................ 6–12 Figure 6‐3. Home | Support page ........................................................................................................... 6–13 Figure 6‐4. Admin | Access page............................................................................................................. 6–14 Figure 6‐5. Admin | SNMP page ............................................................................................................. 6–16 Figure 6‐6. Config | ConvA and ConvB pages ......................................................................................... 6–18 Figure 6‐7. Config | Ref page .................................................................................................................. 6–20 Figure 6‐8. Config | Utility page .............................................................................................................. 6–21 Figure 6‐9. Config | Redundancy page .................................................................................................... 6–22 Figure 6‐10. Config | Serial page ............................................................................................................. 6–23 Figure 6‐11. Status | Summary page ...................................................................................................... 6–24 Figure 6‐12. Status | Faults page ............................................................................................................ 6–26 Figure A‐1. LBC‐4000 Chassis – IDU Module Bays .................................................................................... A–1 Figure B‐1. LBC‐4000 Redundancy – Functional Schematic ...................................................................... B–2 Figure B‐2. LBC‐4000 Redundancy Cabling Schematic .............................................................................. B–2 Figure B‐3. LBC‐4000 Front Panel ............................................................................................................. B–3 Figure B‐4. Config | Redundancy page ..................................................................................................... B–8 viii PREFACE About this Manual This manual provides installation and operation information for the Comtech EF Data LBC‐4000 L‐Band Up/Down Converter System with Ethernet. This is an informational document intended for the persons responsible for the operation and maintenance of the LBC‐4000. Reporting Comments or Suggestions Concerning this Manual Comtech EF Data welcomes comments and suggestions regarding the content and design of this manual. Contact the Comtech EF Data Technical Publications Department: [email protected] Conventions and References Patents and Trademarks See all of Comtech EF Data's Patents and Patents Pending at http://patents.comtechefdata.com. Comtech EF Data acknowledges that all trademarks are the property of the trademark owners. Warnings, Cautions, and Notes A WARNING informs you about a possible hazard that MAY CAUSE DEATH or SERIOUS INJURY. A CAUTION informs you about a possible hazard that MAY CAUSE INJURY or PROPERTY DAMAGE. A NOTE gives you important information about a task or the equipment. A REFERENCE directs you to additional information about a task or the equipment. ix LBC-4000 L-Band Up/Down Converter System with Ethernet Preface Revision 2 MN-LBC4000A Examples of Multi-Hazard Notices Recommended Standard Designations Recommended Standard (RS) Designations have been superseded by the new designation of the Electronic Industries Association (EIA). References to the old RS designation (e.g., RS‐232) may appear when depicting actual text on the serial or Web Server interfaces or the physical unit (e.g., front panel menus or rear panel labeling). All other references in the manual specify the EIA designations. Metric Conversion Comtech EF Data provides non‐Metric to Metric conversions tables on the inside back cover of this manual to assist the operator in cross‐referencing such information. Carefully review the following information: Safety and Compliance Electrical Safety and Compliance The unit complies with the EN 60950 Safety of Information Technology Equipment (Including Electrical Business Machines) safety standard. IF THE UNIT IS OPERATED IN A VEHICLE OR MOVABLE INSTALLATION, MAKE SURE THE UNIT IS STABLE. OTHERWISE, EN 60950 SAFETY IS NOT GUARANTEED. Electrical Installation CONNECT THE UNIT TO A POWER SYSTEM THAT HAS SEPARATE GROUND, LINE AND NEUTRAL CONDUCTORS. DO NOT CONNECT THE UNIT WITHOUT A DIRECT CONNECTION TO GROUND. x LBC-4000 L-Band Up/Down Converter System with Ethernet Preface Revision 2 MN-LBC4000A Sect 3.3 LBC‐4000 Ground and Power Connections Operating Environment DO NOT OPERATE THE UNIT IN ANY OF THESE EXTREME OPERATING CONDITIONS: • AMBIENT TEMPERATURES LESS THAN 0° C (32° F) OR MORE THAN 50° C (122° F). • PRECIPITATION, CONDENSATION, OR HUMID ATMOSPHERES OF MORE THAN 95% RELATIVE HUMIDITY. • UNPRESSURIZED ALTITUDES OF MORE THAN 2000 METRES (6561.7 FEET). • EXCESSIVE DUST. • FLAMMABLE GASES. • CORROSIVE OR EXPLOSIVE ATMOSPHERES. European Union Radio Equipment and Telecommunications Terminal Equipment (R&TTE) Directive (1999/5/EC) and EN 301 489-1 Independent testing verifies that the unit complies with the European Union R&TTE Directive, its reference to EN 301 489‐1 (Electromagnetic compatibility and Radio spectrum Matters [ERM]; ElectroMagnetic Compatibility [EMC] standard for radio equipment and services, Part 1: Common technical requirements), and the Declarations of Conformity for the applicable directives, standards, and practices that follow: European Union Electromagnetic Compatibility (EMC) Directive (2004/108/EC) • • • • Emissions: EN 55022 Class B – Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment. Immunity: EN 55024 – Information Technology Equipment: Immunity Characteristics, Limits, and Methods of Measurement. EN 61000‐3‐2 – Harmonic Currents Emission EN 61000‐3‐3 – Voltage Fluctuations and Flicker. • Federal Communications Commission Federal Code of Regulation FCC Part 15, Subpart B. xi LBC-4000 L-Band Up/Down Converter System with Ethernet Preface Revision 2 MN-LBC4000A TO ENSURE THAT THE UNIT COMPLIES WITH THESE STANDARDS, OBEY THESE INSTRUCTIONS: • Use coaxial cable that is of good quality for connections to the L‐Band Type ‘N’ Rx (receive) female connector. Use Type 'D' connectors that have back‐shells with continuous metallic shielding. Type ‘D’ cabling must have a continuous outer shield (either foil or braid, or both). The shield must be bonded to the back‐shell. Operate the unit with its cover on at all times. • • European Union Low Voltage Directive (LVD) (2006/95/EC) Symbol Description <HAR> ! Type of power cord required for use in the European Community. CAUTION: Double‐pole/Neutral Fusing ACHTUNG: Zweipolige bzw. Neutralleiter‐Sicherung International Symbols Symbol Definition Alternating Current Protective Earth Fuse Chassis Ground Symbol Definition For additional symbols, refer to Warnings, Cautions and Notes listed earlier in this Preface. European Union RoHS Directive (2002/95/EC) This unit satisfies (with exemptions) the requirements specified in the European Union Directive on the Restriction of Hazardous Substances in Electrical and Electronic Equipment (EU RoHS, Directive 2002/95/EC). European Union Telecommunications Terminal Equipment Directive (91/263/EEC) In accordance with the European Union Telecommunications Terminal Equipment Directive 91/263/EEC, the unit should not be directly connected to the Public Telecommunications Network. xii LBC-4000 L-Band Up/Down Converter System with Ethernet Preface Revision 2 MN-LBC4000A CE Mark Comtech EF Data declares that the unit meets the necessary requirements for the CE Mark. Warranty Policy Comtech EF Data products are warranted against defects in material and workmanship for a specific period from the date of shipment, and this period varies by product. In most cases, the warranty period is two years. During the warranty period, Comtech EF Data will, at its option, repair or replace products that prove to be defective. Repairs are warranted for the remainder of the original warranty or a 90 day extended warranty, whichever is longer. Contact Comtech EF Data for the warranty period specific to the product purchased. For equipment under warranty, the owner is responsible for freight to Comtech EF Data and all related customs, taxes, tariffs, insurance, etc. Comtech EF Data is responsible for the freight charges only for return of the equipment from the factory to the owner. Comtech EF Data will return the equipment by the same method (i.e., Air, Express, Surface) as the equipment was sent to Comtech EF Data. All equipment returned for warranty repair must have a valid RMA number issued prior to return and be marked clearly on the return packaging. Comtech EF Data strongly recommends all equipment be returned in its original packaging. Comtech EF Data Corporation’s obligations under this warranty are limited to repair or replacement of failed parts, and the return shipment to the buyer of the repaired or replaced parts. Limitations of Warranty The warranty does not apply to any part of a product that has been installed, altered, repaired, or misused in any way that, in the opinion of Comtech EF Data Corporation, would affect the reliability or detracts from the performance of any part of the product, or is damaged as the result of use in a way or with equipment that had not been previously approved by Comtech EF Data Corporation. The warranty does not apply to any product or parts thereof where the serial number or the serial number of any of its parts has been altered, defaced, or removed. The warranty does not cover damage or loss incurred in transportation of the product. The warranty does not cover replacement or repair necessitated by loss or damage from any cause beyond the control of Comtech EF Data Corporation, such as lightning or other natural and weather related events or wartime environments. xiii LBC-4000 L-Band Up/Down Converter System with Ethernet Preface Revision 2 MN-LBC4000A The warranty does not cover any labor involved in the removal and or reinstallation of warranted equipment or parts on site, or any labor required to diagnose the necessity for repair or replacement. The warranty excludes any responsibility by Comtech EF Data Corporation for incidental or consequential damages arising from the use of the equipment or products, or for any inability to use them either separate from or in combination with any other equipment or products. A fixed charge established for each product will be imposed for all equipment returned for warranty repair where Comtech EF Data Corporation cannot identify the cause of the reported failure. Exclusive Remedies Comtech EF Data Corporation’s warranty, as stated is in lieu of all other warranties, expressed, implied, or statutory, including those of merchantability and fitness for a particular purpose. The buyer shall pass on to any purchaser, lessee, or other user of Comtech EF Data Corporation’s products, the aforementioned warranty, and shall indemnify and hold harmless Comtech EF Data Corporation from any claims or liability of such purchaser, lessee, or user based upon allegations that the buyer, its agents, or employees have made additional warranties or representations as to product preference or use. The remedies provided herein are the buyer’s sole and exclusive remedies. Comtech EF Data shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. xiv LBC-4000 L-Band Up/Down Converter System with Ethernet Preface Revision 2 MN-LBC4000A Getting Help Review the Warranty Policy before contacting Comtech EF Data Technical Support or Customer Service. Contacting Comtech EF Data Contact Comtech EF Data for: • • Technical Support – Product support or training. Customer Service – Information on returning an in‐warranty or out‐of‐warranty product for upgrade or repair. Be prepared to provide the product model number and its serial number. Contact Comtech EF Data Customer & Technical Support during normal business hours (Monday through Friday, 8 A.M. to 5 P.M Mountain Standard Time (MST)): For: LBC‐4000 Technical Support and Service Comtech EF Data Web Site Contact: Telephone +1.480.333.4357 Email [email protected] Fax +1.480.333.2500 Main Page http://www.comtechefdata.com Customer and Technical Support http://www.comtechefdata.com/support.asp RMA (Return Material Authorization) http://www.comtechefdata.com/rmaform.asp Comtech EF Data Main Number +1.480.333.2200 Mailing Address 2114 West 7th Street Tempe, Arizona 85281 USA xv LBC-4000 L-Band Up/Down Converter System with Ethernet Preface Revision 2 MN-LBC4000A Returning a Product for Upgrade or Repair Step 1 Task Go to the Comtech EF Data Home page (http://www.comtechefdata.com). From the SUPPORT column at the bottom of the page, select the Service hyperlink, and read the Return Material Authorization section in its entirety. 2 Request a Return Material Authorization Number: • On the Comtech EF Data Home page: From the SUPPORT column at the bottom of the page, select the RMA Request hyperlink; OR • On the Comtech EF Data Support page: Click [Send RMA Request]; OR • On the Comtech EF Data Service page: Select the Return Material Authorizaion hyperlink; • Fill out the RMA form completely; • Click [Send Email]. Alternately: • Send an e‐mail providing this same detailed information to Comtech EF Data Customer Service ([email protected]). • Contact Comtech EF Data Customer & Technical Support by phone or fax. 3 Pack the product in its original shipping carton and protective packaging. 4 Ship the product back to Comtech EF Data. Shipping charges should be prepaid. xvi Chapter 1. INTRODUCTION 1.1 Overview Comtech EF Data’s LBC‐4000 L‐Band Up/Down Converter System with Ethernet (Figure 1‐1) is designed to interface legacy 70 MHz or 140 MHz equipment to tri‐band or quad‐band block converters. Figure 1-1. Comtech EF Data LBC-4000 L-Band Up/Down Converter With Ethernet 1.2 Features Figure 1‐2 shows the front and rear panels of the LBC‐4000. The LBC‐4000 is a 1RU‐high, 19‐inch wide chassis (Figure 1‐3) that is designed for mounting into a standard 19‐inch equipment rack. The front panel handles allow quick installation into and removal of the unit from the equipment rack. The unit may also be freestanding if desired. The LBC‐4000 drop‐down front panel provides access to the ON/OFF switch and bays for two upconverter modules, or two downconverter modules, or one of each. All operator controls, indicators and displays are located on the LBC‐4000 front panel. External interface connectors, including those intended for Ethernet or serial remote Monitor and Control (M&C), are located on the LBC‐4000 rear panel. 1–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Introduction Revision 2 MN-LBC4000A Feature 1 2 3 4 5 6 7 Description Rack Handles On/Off Switch LED Indicator Groups Keypad Vacuum Fluorescent Display (VFD) Converter ‘A’ IDU Module Bay Converter ‘B’ IDU Module Bay Top: Front Panel in Operating and Service Positions Bottom: Rear Panel Figure 1-2. LBC-4000 Front and Rear Panels (Redundant Unit Shown) LBC‐4000 feature(s): • Meet or exceed MIL‐STD‐188‐164A • Low phase noise • 1 kHz step size • No spectral inversion • 50 dB gain adjustment • Auto band sensing capability • Ethernet or EIA‐485/232 Monitor and Control (M&C) • 70 MHz ±18 MHz IF (140 MHz ±36 MHz optional) • Flexible configuration • 1:1 redundancy availability 1–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Introduction 1.2.1 Dimensional Envelope Figure 1-3. LBC-4000 Dimensional Envelope 1–3 Revision 2 MN-LBC4000A LBC-4000 L-Band Up/Down Converter System with Ethernet Introduction 1.3 Revision 2 MN-LBC4000A Functional Description External equipment, e.g., a modem, is connected to each internal converter module via a standard, off‐the‐shelf coaxial cable. A coaxial cable is also used to connect the output for each module to RF equipment either at the same location or at the antenna location. When configured with the redundancy option, the system may contain two diode “OR‐ed” internal power supplies for increased reliability, and microprocessor‐based Monitor and Control (M&C) functions. Figure 1‐4 depicts the block diagram for a typical LBC‐4000 L‐Band Up/ Downconverter System application. Figure 1-4. LBC-4000 Typical Application Block Diagram 1–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Introduction 1.4 1.4.1 Summary of Specifications Physical & Environmental Weight 25 lbs. (11.34 kg) Maximum Dimensions (excluding connectors) 19”W x 1.75”H (1RU) x 22”D (482.6 x 44.45 x 559.0 mm) (See Figure 1-3) Temperature Operating 32º to 122ºF (0º to 50ºC) Non-operating (Storage) -58º to 160ºF (-50º to 71ºC) Operational Altitude 10,000 ft above sea level Operational Humidity 5 to 95% non-condensing Shock Normal commercial shipping and handling 1.4.2 Prime Power Voltage 90 to 260 VAC Frequency 47 to 63 Hz Dissipation 35 Watts total, two up/downconverters 1.4.3 External Reference Input Frequency 5 or 10 MHz, Auto detect BNC Female connector Input Level ±5 dBm Input Impedance 50Ω 1.4.4 Monitor & Control Serial M&C Interface TIA/EIA-232, TIA/EIA-485, 4-wire DB-9F connector 10/100 Ethernet M&C Interface RJ-45 connector Alarm Form C, DB-9F connector Redundant Switch Connections SMA Female 1–5 Revision 2 MN-LBC4000A LBC-4000 L-Band Up/Down Converter System with Ethernet Introduction 1.4.5 LBC-4000 L-Band Downconverter IDU Input Frequency Range 950 MHz to 2000 MHz, 1 kHz steps Output Frequency 70 MHz ±18 MHz (140 MHz ±36 MHz optional) Input/Output Impedance 50Ω Input Return Loss 15 dB minimum Output Return Loss 20 dB minimum Input connector Type ‘N’ female Output connector Type ‘BNC’ female Gain 35 dB nominal at minimum attenuation Ripple • ±.5 dB over any ±18 MHz for 70 MHz IF units • ±.5 dB over any ±36 MHz for 140 MHz IF units Slope 0.05 dB/MHz User Attenuation Range 0 to 40 dB, in 0.25 dB steps (0.1 dB optional) Output Power, P1dB +13 dBm minimum Third Order Intercept +23 dBm minimum Carrier Spurious -60 dBc Non-Carrier Spurious -60 dBm Stability Over Time ±1 X 10-9/Day Over Temp ±1 x 10-8 32º to 122ºF (0º to 50ºC) 1–6 Revision 2 MN-LBC4000A LBC-4000 L-Band Up/Down Converter System with Ethernet Introduction 1.4.6 LBC-4000 L-Band Upconverter IDU Input Frequency 70 MHz ±18 MHz (140 MHz ±36 MHz optional) Output Frequency 950 MHz to 2000 MHz, 1 kHz steps Input/Output Impedance 50Ω Input Return Loss 18 dB minimum Output Return Loss 15 dB minimum Input connector Type ‘BNC’ female Output connector Type ‘N’ female Gain 25 dB ±1 dB nominal at minimum attenuation Ripple • ±.5 dB over any ±18 MHz for 70 MHz IF units • ±.5 dB over any ±36 MHz for 140 MHz IF units Slope 0.05 dB/MHz User Attenuation Range 0 to 40 dB, in 0.25 dB steps (0.1 dB optional) Input Power Level To ±10 dBm maximum Output Power, P1dB +10 dBm minimum Third Order Intercept +20 dBm minimum Carrier Spurious -60 dBc Non-Carrier Spurious -75 dBm Transmit Phase Noise Exceeds MIL-STD-188-164A Stability Over Time ±1 X 10-9/Day Over Temp ±1 x 10-8 32º to 122ºF (0º to 50ºC) 1–7 Revision 2 MN-LBC4000A LBC-4000 L-Band Up/Down Converter System with Ethernet Introduction Notes: 1–8 Revision 2 MN-LBC4000A Chapter 2. INSTALLATION 2.1 Unpacking and Inspecting the Shipment Figure 2-1. Unpacking and Inspecting the LBC-4000 The LBC‐4000 L‐Band Up/Down Converter System with Ethernet, its Installation and Operation Manual, and its power cord were packaged and shipped in a reusable cardboard carton containing protective foam spacing. 2–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation Step 1 2 3 4 5 2.2 Revision 2 MN-LBC4000A The equipment contains parts and assemblies sensitive to damage by Electrostatic Discharge (ESD). Use ESD precautionary procedures when touching, removing, or inserting PCBs. As shown in Figure 2‐1 – Once opened, inspect the shipment: Task Keep all shipping materials for storage or reshipment. Check the packing list to ensure the shipment is complete. Inspect the equipment for any possible damage incurred during shipment. Contact the carrier and Comtech EF Data immediately and submit a damage report if damage is evident to the shipment. Review the manual carefully to become familiar with operation. Chapter Sect. 2.2 Installation and Mounting Installing Into a Rack Enclosure When mounting the LBC-4000 into a rack enclosure (Figure 2‐2): • PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be connected to the protective earth connection at all times. It is therefore imperative that the unit is properly grounded, using the ground stud provided on the unit rear panel, during installation, configuration, and operation. • PROPER AIR VENTILATION IS REQUIRED. In a rack system where there is high heat discharge, provide forced-air cooling with top- or bottom-mounted fans or blowers. o Make sure there is adequate clearance inside the enclosure, especially at the side for air ventilation. o Air temperature inside the rack enclosure should never exceed 50°C (122°F). For information about custom rack enclosures, contact Comtech EF Data Customer Support during normal business hours or visit the Comtech EF Data Web site (www.comtechefdata.com/support.asp). 2–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation Revision 2 MN-LBC4000A Feature Description 1 Custom Rack Enclosure 2 LBC‐4000 Up/Down Converter 3 Standard Rack Shelving Rack Enclosure Threaded Front Mounting Rail (typical) 4 5 Unit Front Panel 6 User‐supplied Screws Figure 2-2. Installing into a Rack Enclosure Mount the LBC‐4000 in its assigned position in the rack enclosure. Use, as required: • A standard rack‐mounted shelf; • User‐supplied screws to secure the front panel to the rack enclosure threaded front mounting rails; • Comtech EF Data’s optional 4” (KT/6228‐2) or 10” (KT/6228‐3) Rear‐Mounting Support Brackets Kit (Figure 2‐3). • Comtech EF Data’s optional 22” (FP/SL0007), 24” (FP/SL0008) or 26” (FP/SL0006) Side‐ Mounting Rack Slide Set (Figure 2‐4). 2–3 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation Revision 2 MN-LBC4000A 2.2.1 Installing the Optional Rear-Mounting Support Brackets Kit Feature Description Item 1 Back of Unit 2 Rack Enclosure Threaded Rear Mounting Rail (typical) Kit / Quantity Part Number Description 2 HW/10‐32SHLDR Shoulder Screw, #10 4 4 HW/10‐32FLT Flat Washer, #10 3 2 2 HW/10‐32SPLIT Lock Washer, #10 4 2 2 HW/10‐32HEXNUT Hex Nut, #10 5 4 4 HW/10‐32x1/2RK Bolt, #10, Rear Support Bracket 2 – FP/6138‐2 Bracket, Rear Support – 4” – 2 FP/6138‐3 Bracket, Rear Support – 10” KT/6228‐2 KT/6228‐3 1 2 2 6 Figure 2-3. Installing the Optional Rear-Mounting Support Brackets Kit Tools needed to install the KT/6228‐2 (4”) or KT/6228‐3 (10”) Bracket Kit (Figure 2-3): • • A medium Phillips™ screwdriver A 5/32‐inch SAE Allen™ Wrench • An adjustable Crescent™ wrench. 2–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation Revision 2 MN-LBC4000A Follow these steps to install the CEFD‐style chassis kit: Step Task 1 Use the #10 flat washers, #10 split washers, and #10 hex nuts to secure the #10 shoulder screws to the CDM‐800 chassis through the rear right and left side mounting slots. 2 Use the #10 rack bracket bolts to install the rear support brackets onto the rack enclosure threaded rear mounting rails. 3 Mount the unit into the rack enclosure. Ensure that the shoulders of the #10 shoulder screws properly engage into the rear support bracket slots. 2–5 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation Revision 2 MN-LBC4000A 2.2.2 Installing the Optional Side-Mounting Bearingless Rack Slide Set The optional Bearingless Rack Slide Set may be installed into the equipment rack cabinet and onto the sides of the LBC‐4000 as shown in Figure 2‐4 and per the following procedure: Step Task 1 Use the provided mounting hardware to install one slide onto each side of the LBC-4000 chassis. 2 Use the provided mounting hardware to install the slide rail components into each interior side of the equipment rack cabinet. 3 Mount the unit into the front of the equipment rack. Ensure that the slides properly engage the cabinet-mounted slide rails. 4 Continue to slide the converter into the equipment rack to its final operating position. Then, use four user-provided screws to secure the converter to the equipment rack’s right and left threaded front mounting rails (through the front panel mounting slots). CEFD Part Number Description FP/SL0007 Bearingless Rack Slide Set – 22” FP/SL0008 Bearingless Rack Slide Set – 24” FP/SL0006 Bearingless Rack Slide Set – 26” Figure 2-4. Installing the Optional Side-Mounting Bearingless Rack Slide Set 2–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation 2.3 Revision 2 MN-LBC4000A Connecting the Prime Power A power cord for connection to 90‐to‐125VAC or 205‐to‐240VAC power sources is provided with the LBC‐4000. This detachable power cord mates with the AC Prime Power receptacle on the LBC‐4000 rear panel. 2.4 Connecting External Cables Proceed to connect all external cables to the LBC‐4000 rear panel connectors as outlined in Chapter 3. REAR PANEL CONNECTORS. Should difficulties occur, call Comtech EF Data Customer Support for assistance. 2.5 Removing or Installing Converter Modules The LBC‐4000 comes preassembled as ordered for the specific customer application. In the event removal or replacement of the up/downconverter modules is required, complete instructions are provided in Appendix A. UP/DOWNCONVERTER IDU MODULE REMOVAL/RE‐ INSTALLATION. 2–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Installation Notes: 2–8 Revision 2 MN-LBC4000A Chapter 3. REAR PANEL CONNECTIONS 3.1 Cabling Connection Types The LBC‐4000 L‐Band Up/Down Converter System uses a number of different cables. Each cable type is typically dedicated to a specific mode of operation. Not all of these operational interface types may be available with this product. 3.1.1 Coaxial Cable Connections Connector Type Coupling Type Plug Jack Bayonet (Type ‘BNC’ shown) Threaded (Type ‘N’ shown) Figure 3-1. Coaxial Connector Examples The types of coaxial cables used by Comtech EF Data are ‘BNC’, ‘TNC’, ‘N’, ‘F’, and ‘SMA’. Coaxial cables (plugs) and their mating connectors (jacks/sockets) are available in two coupling styles – Bayonet or Threaded: 3–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections Revision 2 MN-LBC4000A • Bayonet Coupling Style – The jack has a pair of guide posts that accommodate the plug’s lockdown slots. This lockdown design provides secure assembly without over‐ tightening the connection. • Threaded Coupling Style – The jack features external threads. The plug shell features internal threads, and has either a knurled outer surface to permit hand‐tightening of the connection, or hex flats to accommodate torqued installation. Connection Instructions: • Bayonet Coupling Connections – Use the plug slots to guide, then slide the plug onto the jack posts. Then, turn the plug clockwise until the jack posts are fully seated within the plug slot. • Threaded Coupling Connections – Engage the plug onto the jack threads, and then turn the plug clockwise until it is fully threaded onto the jack. Do not over‐tighten the connection. 3.1.1.1 Type ‘BNC’ BNC plugs and jacks feature a Bayonet Coupling design. 3.1.1.2 Type ‘TNC’ TNC plugs and jacks feature a Threaded Coupling design similar to Type ‘N’, Type ‘F,’ and Type ‘SMA’ connectors. 3.1.1.3 Type ‘N’ Type ‘N’ connectors feature a Threaded Coupling design similar to Type ‘TNC’, Type ‘F’, and Type ‘SMA’ connectors. 3–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.1.1.4 Revision 2 MN-LBC4000A Type ‘F’ Type ‘F’ connectors feature a Threaded Coupling design similar to Type ‘TNC’, Type ‘N’, and Type ‘SMA’ connectors. 3.1.1.5 Type ‘SMA’ (Subminiature Version ‘A’) Type ‘SMA’ connectors feature a Threaded Coupling design similar to Type ‘TNC’, Type ‘N’, and Type ‘F’ connectors. 3.1.2 D-Subminiature Cable Connections Type ‘D’ Connection Type Example Chassis Receptacles: Female (top) Male (bottom) Type ‘D’ Cable with Jack Screws (female shown) Figure 3-2. D-Subminiature Connector Examples D‐Subminiature connectors are also called Type ‘D’ or ‘D‐Sub’ connectors. The connector pair features multiple rows of pins (male side) coupled to mating sockets (female side). The cable plug and chassis receptacle each feature a D‐shaped profile that interlock to ensure proper pin orientation and connector seating. Either chassis receptacle gender features two jack nuts for secure assembly of the cable plug to the chassis receptacle. Whether its gender is male or female, the cable plug features two jack screws for secure connection to the jack nuts provided on the mating chassis receptacle. The jack screws may be hand tightened or tightened with a standard flat‐blade screwdriver. 3–3 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections Revision 2 MN-LBC4000A Connection Instructions – Orient the plug to the receptacle in the proper position. Press firmly into place. Use the jack screws to secure the plug to the receptacle jack nuts. Do not over‐ tighten. 3.1.3 Circular Cable Connections Circular connectors are intended for weatherproof outdoor applications. The connector pairs feature a sleeve lock configuration, with an array of pins (male side) coupled to mating sockets (female side). Feature Description 1 Primary Alignment features 2 Secondary Alignment features 3 Sleeve Lock features Connection Instructions – Engage all of the alignment and lock features between the male connector (on the interconnection cable) and female socket. To install the male connector into the female connector: 1. Engage the primary and secondary alignment tabs on the male connector with the mating cutouts on the female socket. 2. Push the male connector into the female socket. 3. Turn the male connector sleeve clockwise until the sleeve lock cutouts engage fully with the female socket tabs and you hear a “click” sound 3.1.4 RJ-45, RJ-48 Cable Connections The plug for an RJ‐45 or RJ‐48 cable features a flexible tab. The RJ‐45 or RJ‐48 jack features a mating slot. This design configuration assures proper installation and pin orientation. Connection Instructions – Press down the tab on the cable plug, and then insert the plug into the RJ‐4x jack. The connection is complete when the tab ‘clicks’ into position inside the jack. 3–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.2 Revision 2 MN-LBC4000A LBC-4000 Cabling Connections Figure 3-3. LBC-4000 Rear Panel Connectors (Redundancy Unit Shown) The LBC‐4000 rear panel connectors (Figure 3‐3) provide all necessary external connections between the unit and other equipment. Table 3‐1 summarizes the connectors provided here, grouped according to service function. Table 3-1. LBC-4000 Connectors Connector Group (Sect.) RF/IF (Sect. 3.2.1) Utility (Sect.3.2.2) Connector Name RF OUT/IN IF IN/OUT RF OUT/IN IF IN/OUT EXT REF IN 10/100 ETHERNET RELAY COM 1 Ref Des Connector Type Function P1 J1 Type ‘N’ female Type ‘ BNC ’ female Type ‘N’ female Type ‘BNC’ female Type ‘BNC’ female RJ-45 9-Pin Type ‘D’ female 9-Pin Type ‘D’ male IF Type ‘BNC’ female RF Type ‘SMA’ female Unit B Module RF output/input Unit B Module IF input/output Unit A Module RF output/input Unit A Module IF input/output External10 MHz Reference input 10/100 Ethernet M&C Form C Unit Alarm Serial M&C Opt. Redun (top): To J4 IF In/Out Opt. Redun (bot): To Modem Opt. Redun (top): To Termination Opt. Redun (bot): To J6 IF In/Out Opt. Redun (top): To J5 RF In/Out Opt. Redun (bot): To PA or LNA Opt. Redun (top): To Termination Opt. Redun (bot): To J7 RF In/Out J4 J5 J6 J7 J2 B SEC Optional Redundancy RF/IF (Sect. 3.2.3) A PRI B SEC A PRI 1. The European EMC Directive (EN55022, EN50082‐1) requires using properly shielded cables for DATA I/O. These cables must be double‐shielded from end‐to‐ end, ensuring a continuous ground shield. 2. See Sect. 3.1 Cabling Connections Types for information about each connector type and its connection instructions. 3–5 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.2.1 Revision 2 MN-LBC4000A RF/IF Connectors 3.2.1.1 J4 | RF OUT/IN Unit B Connector (Type ‘N’ Female) The J4 | RF OUT/IN interface is a Type 'N' female connector that provides either an L‐Band output signal interface (with the Downconverter IDU installed), or an L‐Band input signal interface (with the Upconverter IDU installed). 3.2.1.2 J5 | IF IN/OUT Unit B Connector (Type ‘BNC’ Female) The J5 | IF IN/OUT interface is a Type 'BNC' female connector that provides either a downconverted IF input signal (with the Downconverter IDU installed), or an upconverted IF output signal (with the Upconverter IDU installed). 3.2.1.3 J6 | RF OUT/IN Unit A Connector (Type ‘N’ Female) The J6 | RF OUT/IN interface is a Type 'N' female connector that provides either an L‐Band output signal interface (with the Downconverter IDU installed), or an L‐Band input signal interface (with the Upconverter IDU installed). 3.2.1.4 J7 | IF IN/OUT Unit A Connector (Type ‘BNC’ Female) The J7 | IF IN/OUT interface is a Type 'BNC' female connector that provides either a downconverted IF input signal (with the Downconverter IDU installed), or an upconverted IF output signal (with the Upconverter IDU installed). 3–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.2.2 Revision 2 MN-LBC4000A Utility Connectors 3.2.2.1 3.2.2.2 J2 | EXT REF (External Reference) Input Connector (Type ‘BNC’ Female) The J2 | EXT REF IN (External Reference Input) is used to supply a master reference to the entire chassis. The input signal supplied here by the user is used for phase‐ locking the internal 10MHz reference oscillator to a customer‐provided 5 or 10 MHz station clock. The impedance is matched for 50/75Ω, and requires a level in the range 0.5V‐4.0Vpp square or sine wave. 10/100 Ethernet Connector (RJ-45) Connector Type Name RJ-45 female modular jack 10/100 ETHERNET Direction In/Out • The ‘10/100 ETHERNET’ port is used for both Ethernet terrestrial data traffic and remote management and control (M&C) of LBC‐4000 functions via Telnet/SNMP/HTTP. o Ports operate at 10/100/1000 Mbps, half and full duplex, auto‐ negotiating. o The typical maximum Ethernet packet size is 1522 bytes (including Ethernet headers and CRC). 3–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.2.2.3 Revision 2 MN-LBC4000A P1 | RELAY (Summary Fault Output) Connector (DB-9F) The P1 | RELAY summary fault output is a 9‐pin Type "D" female (DB‐9F) connector. Table 3-2. P1 | RELAY Connector Pinouts Pin # 1 6 Description SUMFLT1_NC SUMFLT1_COM 2 7 SUMFLT1_NO NC 3 8 SUMFLT2_NC SUMFLT2_COM 4 9 SUMFLT2_NO NC 5 GND Notes – For Normal Fault Relay Logic: 1. Pin 1 to Pin 6: OK – No Fault 2. Pin 2 to Pin 6: Fault 3–8 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.2.2.4 Revision 2 MN-LBC4000A J1 | COM1 (EIA-485/232 Interface) Connector (DB-9F) The J1 | COM1 EIA‐485/232 Interface is a 9‐pin Type "D" female (D‐9F) connector. The tables that follow provide the connector pinouts for the EIA‐485 2‐Wire or 4‐Wire interfaces, and the EIA‐232 interface. Table 3-3. J1 | COM1 2-Wire EIA-485 Interface Connector Pinouts Table 3-4. J1 | COM1 4-Wire EIA-485 Interface Connector Pinouts Pin # Pin # 1 Description GND (Ground) 1 6 Description GND (Ground) 6 2 2 7 7 3 8 3 +RX/TX (Signal) 4 9 8 +RX/TX (Signal) -RX/TX (Signal Complement) 5 4 +TX (Signal) 5 -TX (Signal Complement) 9 -RX/TX (Signal Complement) Note: Pins 8 & 9 are the loop to the next converter. Table 3-5. J1 | COM1 EIA-232 Interface Connector Pinouts Pin # Description 1 6 DSR (Unit Ready) – always high 2 7 TD (Transmit Data) RTS (Request to Send) – Looped to CTS 3 8 RD (Receive Data) CTS (Clear to Send) 4 9 5 GND (Ground) 3–9 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.2.3 Revision 2 MN-LBC4000A Optional 1:1 Redundancy Connectors See Figure B‐2 in Appendix B. LBC‐4000 REDUNDANCY OPERATION for interconnection between these connectors to others located on the LBC‐4000 rear panel and on other external equipment. 3.2.3.1 Optional IF Connectors (Type ‘BNC’ Female) The IF Primary A / Secondary B connector pairs provide the IF “baseball” switch for optional redundant operations. Connector Name Ref Des Connector Type Function (See App. C Figure C-2) Type ‘BNC’ female Opt. Redun (top): To J4 IF In/Out Opt. Redun (bot): To Modem Opt. Redun (top): To Termination Opt. Redun (bot): To J6 IF In/Out B SEC IF A PRI 3.2.3.2 Optional RF Connectors (Type ‘SMA’ Female) The RF Primary A / Secondary B connector pairs provide the RF “baseball” switch for optional redundant operations. Connector Name Ref Des Connector Type Function (See App. C Figure C-2) Type ‘SMA’ female Opt. Redun (top): To J5 RF In/Out Opt. Redun (bot): To PA or LNA Opt. Redun (top): To Termination Opt. Redun (bot): To J7 RF In/Out B SEC RF A PRI 3.3 LBC-4000 Ground and Power Connections Figure 3-4. LBC-4000 Ground and Power Interfaces 3–10 LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.3.1 Revision 2 MN-LBC4000A Chassis Ground Interface PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be connected to the protective earth connection at all times. It is therefore imperative that the unit is properly grounded, using the ground stud provided on the unit rear panel, during installation, configuration, and operation. The AC power interface provides the safety ground. Use the #10‐32 stud, located adjacent to the power interface, for connecting a common chassis ground among equipment. 3.3.2 Chassis Power Interfaces 3.3.2.1 AC Prime Power Connector A detachable power cord, provided with the LBC‐4000, mates with the AC (Alternating Current) Prime Power receptacle for connection to 90 to 125 VAC, or 205 to 240 VAC power sources. 3.3.2.2 DC Filter Input Module The DC (Direct Current) Filter Input Module input voltage is 48VDC nominal, ‐36 VDC minimum, ‐72VDC maximum. Table 3‐6 lists the pinouts for this interface. Table 3-6. DC Input Filter Module Pinouts Pin # Signal Name Wire Colors A Negative Black -48 VDC 0 VDC B Ground Green/Yellow Earth Ground Earth Ground C Positive Red 0 VDC +48 VDC 3–11 Wiring Options LBC-4000 L-Band Up/Down Converter System with Ethernet Rear Panel Connections 3.3.2.3 Revision 2 MN-LBC4000A Applying Power to the LBC-4000 The prime power switch is mounted behind the front panel. To access the switch, loosen the three front panel thumb screws, slide the front panel out from the chassis, and then drop down the panel. Prior to turning on power to the unit, check to ensure that installation is complete, and verify that the LBC‐4000 is connected to the proper prime power source, RF Input, and RF Output. Switch on the unit and verify the cooling fan is operational, the LED indicators illuminate as expected, and the Vacuum Fluorescent Display is readable. 3–12 Chapter 4. UPDATING FIRMWARE 4.1 Updating Firmware via the Internet TO ENSURE OPTIMAL PERFORMANCE, IT IS IMPORTANT TO OPERATE THE LBC‐4000 WITH ITS LATEST AVAILABLE FIRMWARE. The LBC‐4000 L‐Band Up/Down Converter System with Ethernet is factory‐shipped with the latest version of operating firmware. If you need to update the firmware, you can acquire the download from the Comtech EF Data Web site (www.comtechefdata.com) or from Comtech EF Data Customer Support during normal business hours via e‐mail or on CD by standard mail delivery. The LBC‐4000 Firmware Update process is as follows: • Perform the update without opening the LBC‐4000 by connecting the Ethernet and the serial ports of a user‐supplied PC to the LBC‐4000 rear panel ‘10/100 ETHERNET’ port and the ‘J1 | COM1’ serial port. • Download the firmware update via the Internet to the user PC. • Transfer the firmware update files, via File Transfer Protocol (FTP), from the user PC to the LBC‐4000. 4–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware 4.2 Revision 2 MN-LBC4000A Getting Started: Preparing for the Firmware Download 1. First, identify the firmware number and its version number. User‐supplied items needed: • A Microsoft Windows‐based PC, equipped with available serial and Ethernet ports; a compatible Web browser (e.g., Internet Explorer); and a terminal emulator program (e.g., Tera Term or HyperTerminal). • A 9‐pin serial cable to connect the PC serial port to the LBC‐4000. • A CAT5 Ethernet cable to connect the PC Ethernet port to the LBC‐4000. A. Use the 9‐pin serial cable to connect the LBC‐4000 ‘J1 | COM1’ port to a serial port on the user PC. B. Use an Ethernet hub, switch, or direct cable connection to connect the LBC‐4000 ‘10/100 ETHERNET’ port to an Ethernet port on the user PC. C. On the PC – configure the terminal emulator program. Refer to your terminal emulator program HELP feature or user guide for operating and configuration instructions. Configure the utility program serial port communication and terminal display operation: • 38400 bps (Baud Rate) • Parity = NO • Local Echo = ON • 8 Data Bits • Port Flow Control = NONE • 1 Stop Bit • Display New line Rx/Tx: CR D. On the LBC‐4000 – turn on the power. The on/off switch is located behind the front panel. E. Obtain the firmware information via one of the following methods: • From the LBC‐4000 Front Panel VFD (Vacuum Fluorescent Display) – The firmware version number is displayed on the top‐level ‘splash’ screen. Press the [CLR] several 4–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware Revision 2 MN-LBC4000A times to get to the top‐level display if not visible. Additionally, review the information provided on the UTILITY Æ FIRMWAREÆ INFO Æ IMAGE#1 or IMAGE#2 screens. • On the user PC – Use the terminal emulator program to log in to the LBC‐4000, and then use Serial Remote Control to obtain, and make note of, the firmware information: Type (without the quotes) “<0/FRW?<cr>” at the command prompt to query the LBC‐4000 for its Firmware Number and Release Version. See Chapter 6. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for information and instructions on using Serial Remote Control. • On the user PC – Use the LBC‐4000 Web Server Interface. Use a Web browser (e.g., Internet Explorer) to log in to the LBC‐4000 Web Server Interface and review the Firmware Information section of the ‘Config | Utility’ page. There, make note of the firmware loads: See Chapter 5. ETHERNET‐BASED REMOTE PRODUCT MANAGEMENT for information and instructions on using the LBC‐4000 Web Server Interface. 2. Next, create a temporary folder (subdirectory) on the user PC for the firmware archive download. • Drive letter ‘c:’ is used in these examples. Any valid, writable drive letter can be used. • Typical for all tasks: Type the command without quotes, and then press Enter to execute. There are several ways the user may use create a temporary folder on a Windows‐based PC: A. Use the Windows Desktop to create and rename the temporary folder. • Right‐click anywhere on the desktop to open the popup submenu, and then select New > Folder to create the new, temporary folder on the desktop. • Right‐click on the new folder and then select ‘Rename’ from the popup submenu. Rename this folder to "temp" or some other convenient, unused name. 4–3 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware Revision 2 MN-LBC4000A B. Use Windows Explorer to create and rename the temporary folder. • • Select File > New > Folder to create the new, temporary folder in the active location. Right‐click the ‘New Folder’ folder name, and then rename this folder to "temp" or some other convenient, unused name. C. Use the ‘Run’ and ‘Browse’ windows to create and rename the temporary folder. • • • • Select [Start] on the Windows taskbar and then click the Run... icon. The ‘Run’ window will open. Click [Browse] in the ‘Run’ window. The ‘Browse’ window will open. Click the Create New Folder icon in the ‘Browse’ window to create the new folder in the active location. Right‐click the ‘New Folder’ folder name, and then rename this folder to “temp” or some other convenient, unused name. 4–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware Revision 2 MN-LBC4000A D. Use Windows Command‐line to create the temporary folder. • • First, click [Start] on the Windows taskbar, and then click the ‘Run...’ icon (or, depending on Windows OS versions prior to Windows 95, click the ‘MS‐DOS Prompt’ icon from the Main Menu). Next, open a Command‐line window… o o For Windows 95 or Windows 98 – Type “command”. For any Windows OS versions later than Windows 98 – Type “cmd” or “command”. o Alternately, from [Start], select All Programs > Accessories > Command Prompt. o Finally, from the Command‐line ‘c:\>’ prompt, type “mkdir temp” or “md temp” (mkdir and md stand for make directory), and then click [OK]. There should now be a ‘temp’ folder created and available for placement of the firmware file download. 4–5 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware 4.3 Revision 2 MN-LBC4000A Downloading and Extracting the Firmware Update 1. First, download the firmware update file from the Comtech EF Data Web site: A. Go online to www.comtechefdata.com. B. On the Main page – Under Support Information or the Support tab, select the Software Downloads hyperlink. C. On the Software Downloads page – Click Download Flash and Software Update Files. D. On the Flash Updates Index page – Select the (Select a Product Line) Converters hyperlink. E. On the Converters product page – Select the LBC‐4000 product hyperlink; F. Select the appropriate firmware archive EXE or ZIP file download hyperlink. • About Firmware Numbers, File Versions, and Formats: The Comtech EF Data Web site catalogues its firmware update files by product type (e.g., router, modem, etc.), the specific model, and optional hardware configurations. The LBC‐4000 firmware download hyperlink appears as F0020503X_V###, where ‘X’ denotes the revision letter, and ‘###’ represents the firmware version number (e.g., V124 = Version 1.2.4). • About File Archive Formats: Comtech EF Data provides its downloadable files in two compressed archive formats: *.exe (self‐extracting) and *.zip (compressed). The *.exe file does not require a file archiver and compression utility program such as PKZIP for Windows, WinZip, ZipCentral, etc. (PKZIP for DOS is not supported due to file naming conventions). Comtech EF Data does not provide this utility program. Some firewalls do not allow the download of *.exe files. Download the *.zip file instead, and extract the firmware files from the archive download with a user‐supplied utility program. For detailed information on handling archived files, refer to the utility program Help documentation. G. Download the archive file to the temporary folder. • Once the EXE or ZIP hyperlink is selected the ‘File Download’ window opens and prompts selection of [Open] or [Save]: 4–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware o o Revision 2 MN-LBC4000A Click [Open] to turn over file extraction to the user‐supplied utility program. Be sure to extract the firmware files to the ‘temp’ folder created earlier. Click [Save] to open the ‘Save As’ window. Be sure to select and [Save] the archive *.exe or *.zip file to the ‘temp’ folder created earlier. Otherwise, click [Cancel] to quit and exit the file download process. 2. Next, extract the firmware files from the archive file. • (If not already done with File Download > [Open]) Extract the firmware files from the downloaded *.exe or *.zip archive file with the user‐supplied utility program: o Double‐click on the archive file name, and then follow the prompts provided by the user‐supplied utility program. Extract, at a minimum, two files: FW‐0020503x_LBC4000_Ethernet_#_#_#.bin – The Firmware Bulk image file (where ‘x’ denotes the revision letter and ‘#_#_#’ denotes the firmware version number), and LBC‐4000ReleaseNotes_v#‐#‐#.pdf – The Firmware Release Notes PDF file (where ‘#‐#‐#’ denotes the firmware version number). 3. Confirm availability of the firmware files in the temporary folder. There are several ways the user may view the contents of the temporary folder on a Windows‐based PC: A. From the Windows Desktop: • • • Double‐left‐click the ‘temp’ folder saved to the Windows Desktop. Use Windows Explorer to locate, and then double‐left‐click the ‘temp’ folder. Use the ‘Browse‘ window ([Start] > ...Run > [Browse]) to locate, and then double‐ click the ‘c:\temp’ folder. B. Using Command‐line: • Type “cd c:\temp” at the Command‐line prompt to change to the temporary directory created earlier using Command‐line. 4–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware • Revision 2 MN-LBC4000A Type “dir” to list the files extracted to the temporary directory from the downloaded archive file. The firmware files have been successfully downloaded and are now available for transfer to the LBC‐4000. 4.4 Performing the Ethernet FTP Upload Procedure To proceed with the firmware update procedure, assumptions are made that: • The LBC‐4000 is connected to a user‐supplied, Windows‐based PC, and: o The PC serial port is connected to the LBC‐4000 ‘J1 | COM1’ port. o The PC Ethernet port is connected to the LBC‐4000 ‘10/100 ETHERNET’ port with a user‐supplied hub, switch, or direct Ethernet cable connection. o The PC is running a terminal emulation program (for operation of the LBC‐4000 Serial or Telnet interfaces) and a compatible Web browser (for operation of the LBC‐4000 Web Server Interface). • The latest firmware files have been downloaded or otherwise received from Comtech EF Data and are available on the user PC in an accessible temporary folder. 1. Use Command‐Line to send a ‘PING’ command to confirm proper connection and communication between the user PC and the LBC‐4000: • Obtain the Management IP Address of the unit using the LBC‐4000 Front Panel, Serial Remote Control, or the Web Server Interface: o Using the LBC‐4000 Front Panel – obtain the Management IP Address from the CONFIG Æ REMOTEÆ ETHERNET Æ ADDRESS Æ IP ADDRESS/RANGE screen. o Using Serial Remote Control – type the “<1/IPA?” remote query (without quotes) at the command prompt. The unit returns the configured Management IP Address: >0001/IPA=192.168.001.004.24 (default) o Using the LBC‐4000 Web Server Interface – View the entry for IP Address/Range in the ‘Network Maintenance’ section of the ‘Config | Admin’ page: 4–8 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware • Revision 2 MN-LBC4000A Once the Management IP Address is known – use Command‐line to PING: Type “ping xxx.xxx.xxx.xxx” at the Command‐line prompt (where ‘xxx.xxx.xxx.xxx’ is the unit Management IP Address). The response should confirm whether the unit is properly connected and communicating. 2. Use Command‐line to transfer (FTP) the files from the user PC to the LBC‐4000: • Type "ftp xxx.xxx.xxx.xxx" (where ‘xxx.xxx.xxx.xxx’ denotes the unit Management IP Address). • Enter the Admin User Name (there will be no prompt for a password) to complete login. • Type “bin” to set the binary transfer mode. • Type "prompt" and then type "hash" to facilitate the file transfers. • Type "put FW‐0020503x_LBC4000_Ethernet_#_#_#.bin bulk:" (where ‘x’ denotes the revision letter, and #_#_# denotes the FW version) at the Command‐line prompt, without quotes, to begin the file transfer. The destination “bulk:” must be all lower‐ case. Approximately one minute is required to transfer the file. • Next, the PC should report that the file transfer has occurred. The VFD will first display “Programming App Flash … Please wait”, and then “Programming main FPGA … Please wait”. In the event you receive the “Connection closed by remote host.” message, wait another minute before continuing. The LBC‐4000 update sometimes takes longer than the FTP client allows. • Type "bye" to terminate the FTP session, and then close the Command‐line window. 3. Use the LBC‐4000 Serial Interface, or review the Firmware Information section of the LBC‐4000 Web Server Interface ‘Config | Utility’ page to verify that the PC‐to‐Unit FTP file transfer was successful. 4. Use the LBC‐4000 Web Server Interface to select the firmware and reboot the unit: A. Select the desired image (boot) Slot: • Using the LBC‐4000 Front Panel – Select the desired image to boot from the UTILITY Æ FIRMWAREÆ SELECT screen, and then press [ENT]. 4–9 LBC-4000 L-Band Up/Down Converter System with Ethernet Updating Firmware • Revision 2 MN-LBC4000A Using the LBC‐4000 Web Server Interface – Using the ‘Next Reboot Image’ drop‐ down menu on the ‘Config | Utility’ page, select Latest, 1, or 2, and then click [Submit]. By default, the unit will boot from the Slot storing the firmware version number that has the latest date (Next Reboot Image: Latest). ‘Next Reboot Image’ may also be set to force the unit to boot up using either firmware image loaded in Slot 1 or Slot 2. B. Reboot the LBC‐4000: • • On the LBC‐4000 Web Server Interface ‘‘Config | Utility’ page, click [Reboot Now] in the Perform Soft Reboot section of the page to reboot the LBC‐4000 using the Current Active Firmware Image. Wait while the LBC‐4000 reboots. Verify the new firmware version has booted by observing the firmware version number displayed on the Converter front panel (where X.X.X represents the properly transferred firmware version number), for example: LBC-4000 Ver: X.X.X SN:XXXXXXXXX 5. To load the second image, repeat steps 2 through 4. The LBC‐4000 is now operating with its latest firmware. The firmware update process is now complete. 4–10 Chapter 5. FRONT PANEL OPERATION 5.1 Introduction Featur e See Chapter Section... Description Function 1 Rack Handles The handles allow quick installation into and removal of the unit from an equipment rack. 2 Prime Power Switch The Prime Power Switch is located inside the front panel rear panel. Loosen the thumb screws, slide the front panel out from the chassis and then swing down. 3.3.2.3 5.1.1 3 Converter LED Indicator Group The two groups of LEDs indicate, in a summary fashion, the status of each converter. 5.1.2 4 Keypad The keypad comprises six keyswitches behind a flat membrane. Enter data via the keypad. 5.1.3 5 Vacuum Fluorescent Display (VFD) The VFD is an active display showing two lines of 24 characters each. It produces a blue light with adjustable brightness. Nested menus, data, prompts, and messages are displayed on the VFD. 5.1.4 Figure 5-1. LBC-4000 Front Panel 5–1 2.2 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.1.1 Revision 2 MN-LBC4000A Energizing the LBC-4000 Chapter 2. INSTALLATION Chapter 3. REAR PANELCONNECTIONS The prime power switch is mounted behind the front panel. To access the switch, loosen the three front panel thumb screws, slide the front panel out from the chassis, and then drop down the panel. Prior to turning on power to the unit, check to ensure that installation is complete, and verify that the LBC‐4000 is connected to the proper prime power source, RF Input, and RF Output. Switch on the unit and verify that the cooling fan is operational, the LED indicators illuminate as expected, and the Vacuum Fluorescent Display is readable. 5.1.2 CONV A and CONV B LED Indicators The operational state of the LBC‐4000 is represented by two sets of five front panel LED indicators – one set each for – CONV A and CONV B. The function of the LEDs are as follows: LED STATE WHEN LIT, THE DESIGNATED SIDE... SUM FAULT Red ...has active faults. MUTE Amber ...is in Mute Mode. ONLINE Green ...is operational. UP Green ...is operating as an Up Converter. DOWN Green ...is operating as a Down Converter. 5–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.1.3 Revision 2 MN-LBC4000A Keypad The keypad has an auto‐repeat feature. If a key is held down for more than 1 second, the key action will repeat, automatically, at the rate of 15 keystrokes per second. This is particularly useful when editing numeric fields, with many digits, such as frequency or data rate. The function of the keypad is as follows: KEY USE THIS KEY TO... [ENT] (ENTER) ...display the nested menu for a selected function, or to execute (save) a configuration change. [CLR] (CLEAR) ...back out of a selection or to cancel a configuration change that has not been executed using ENTER. Press [CLR] to return to the previous menu screen. [←] [→] (Left, Right) ...navigate between available selections, or to move the cursor position, on any menu screen. [↑] [↓] (Up, Down) ...scroll through pre-defined parameter settings that are available at the current cursor position, and to change (edit) the alphanumeric selection (i.e., numbers for configuration data, letters for text strings) at the current cursor position. 5–3 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.1.4 Revision 2 MN-LBC4000A Vacuum Fluorescent Display (VFD) The LBC‐4000 features a Vacuum Fluorescent Display (VFD). The VFD is an active display showing two lines of 24 characters each. It produces a blue light with a user‐adjustable brightness. Compared to a Liquid Crystal Display (LCD), it provides superior viewing characteristics and does not suffer problems of viewing angle or contrast. 5.1.4.1 Opening Screen LBC-4000 Ver: X.X.X SN:XXXXXXXXX This screen is displayed whenever power is first applied to the unit. After turning on the prime power, this VFD ‘splash’ display indicates the converter model number – i.e., ‘LBC‐4000’ – along with the version number of the installed firmware, and the serial number assigned to the unit in use. On most menu screens, you will observe a flashing solid block cursor, which blinks at a once‐per‐ second rate. This indicates the currently selected item, digit, or field. Where this solid block cursor would obscure the item being edited (e.g., a numeric field) the cursor will automatically change to an underline cursor. Press any key to restore the previous screen. You may access the opening screen from any location within the LBC‐4000 menu structure by pressing the [CLR] key repeatedly. Otherwise, press any key to access the top‐level (main) menu. 5.1.4.2 Screen Saver If you were to display the same screen for weeks at a time, the display could become ‘burnt’ with this image. To prevent this, the unit has a ‘screen saver’ feature, which will activate after 1 hour. The top line of the display will display the user‐definable circuit ID, and the bottom line will display ‘Press any key...’. The message moves from right to left across the screen, and then wraps around. Press any key to restore the previous screen. 5–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.2 Revision 2 MN-LBC4000A Top-level (Main) Menu CONFIG MONITOR UTILITY FAULTS Figure 5‐2 illustrates the hierarchal structure of the LBC‐4000 menu tree. The tree format is designed for access and execution of all converter control functions, and to prevent execution of an invalid entry by the operator. Figure 5-2. LBC-4000 Front Panel Menu Tree 5–5 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A Each menu branch available from the top‐level (main) menu, the functional description of each branch, and its content section in this chapter, is identified as follows: Menu Branch Sect Description CONFIG 5.2.1 (Configuration) Use to fully configure the LBC-4000A. MONITOR 5.2.2 Use to monitor the alarm status of the unit, view the log of stored events, and display the Receive Parameters screen. FAULTS 5.2.3 Use to view information on the unit, without having to access configuration screens. UTILITY 5.2.4 (Utility) Use to perform miscellaneous functions, such as setting the Real-time clock, adjusting the display brightness, etc. Use the [←][→] arrow keys to select from the choices shown, and then press [ENT]. 5.2.1 CONFIG (CONFIGURATION) CONV-A REDUND CONV-B REMOTE REFADJ SPECT-INV Use the [←][→] arrow keys to select from the submenu choices shown, and then press [ENT]. Each submenu available from the Configuration menu branch – typical for Converter A or Converter B – its content section in this chapter, and the functional description of each submenu is identified as follows: Submenu Sect Description CONV-A CONV-B 5.2.1.1 (Converter Unit A or B) Displays the current configuration of the selected converter, including the frequency, attenuation, and slope. REMOTE 5.2.1.2 (Remote Control) Defines whether the unit is being controlled locally or remotely, and identifies the unit address, interface type, and rate and format of the baud parameters. REDUND 5.2.1.3 (Redundancy – overview only) Identifies the redundancy state and mode (refer to Appendix B. LBC-4000 REDUNDANCY OPERATION for detailed information). REFADJ 5.2.1.4 (Reference Oscillator Adjustment) Adjusts the reference oscillator. SPECT-INV 5.2.1.5 (Spectrum Inversion) 5–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.2.1.1 Revision 2 MN-LBC4000A CONFIG: CONV-A or CONV-B (Converter Unit A or Unit B) CONFIG CnvX: (IF=YYYMHz) FREQ/MUTE ATTN/SLOPE Where ‘X’ is the selected converter – CnvA (Converter Unit A) or CnvB (Converter Unit B) – and ‘YYY’ indicates its operating frequency (70 or 140 MHz), use the [←][→] arrow keys to select FREQ/MUTE or ATTEN/SLOPE, and then press [ENT]. CONFIG CnvA or CnvB Æ FREQ/MUTE CONFIG CnvX: CMM=ON Frq=01980.000MHz Rx=ON To select the CMM (Configuration Mute Mode): Use the [←][→] arrow keys to select the mute parameter, and then use the [↑][↓] arrow keys to select ON or OFF. Use the [←][→] arrow keys to select the parameter to edit – CMM, Freq, or – depending on whether the unit is an Upconverter or Downconverter – Rx or Tx. To set the converter’s operating frequency: Use the [←][→] arrow keys to select a digit to edit, and then use the [↑][↓] arrow keys to change that digit. Repeat for all digits until the desired frequency has been defined. To select the Tx/Rx mute status: Use the [←][→] arrow keys to select the mute parameter, and then use the [↑][↓] arrow keys to select ON or OFF. Press [ENT] when done. CONFIG CnvA or CnvB Æ ATTEN/SLOPE When ATTEN/SLOPE is selected for CnvA: CONFIG CnvA: Ofst=+0.0dB Atten=00.00dB Slope=0.0 When ATTEN/SLOPE is selected for CnvB: CONFIG CnvB: Atten=00.00dB Slope=0.0 For either, use the [←][→] arrow keys to select the parameter to edit – Atten or Slope. To set the converter’s attenuation: Use the [←][→] arrow keys to select a digit to edit, and then use the [↑][↓] arrow keys to change its value. To set the converter’s slope value: Use the [↑][↓] arrow keys to select, in 0.1 increments, a value between 0.0 and 1.0. 5–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A For the CONFIG: Conv‐A Æ ATTEN/SLOPE menu, the Ofst (Gain Offset) command is available only if redundancy is enabled. See Appendix B. LBC‐4000 REDUNDANCY OPERATION for further details on using this command in redundancy applications. Press [ENT] when done. 5.2.1.2 CONFIG: REMOTE (Remote Control) Remote Control: LOCAL SERIAL ETHERNET Use the [←][→] arrow keys to select LOCAL, SERIAL or ETHERNET, and then press [ENT]. CONFIG: Remote Control Æ LOCAL When Remote Control Mode=LOCAL, remote control is disabled although remote monitoring is still possible. CONFIG: Remote Control Æ SERIAL Serial Mode = RS-232 Add=0001 Baud=9600 8-N-1 On the top line, to select the serial mode: Use the [↑][↓] arrow keys to select select RS‐232 or RS‐485, and then press [ENT]. On the bottom line, to set the address: Use the [←][→] arrow keys to navigate to the Address setting. Next, use the [←][→] arrow keys to select a digit to edit, and then use the [↑][↓] arrow keys to change its value. The valid range of addresses is from 0001 to 9999. Press [ENT] when done. On the bottom line, to set the baud rate: Use the [←][→] arrow keys to navigate to the Baud setting. Then, use the [↑][↓] arrow keys to set the Baud rate of the remote control bus (connected locally to the M&C computer): 100, 2400, 4800, 9600, 19K2 (19200), or 38K4 (38400) baud are available. On the bottom line, to select the asynchronous character format: Use the [←][→] arrow keys to navigate to the format setting. Then, use the [↑][↓] arrow keys to select the asynchronous character format as: 8N1 (8 data bits, no parity, 1 stop bit); 7O2 (7 data bits, odd parity, 2 stop bits); or 7E2 (7 data bits, even parity, 2 stop bits). Press [ENT] when done. CONFIG: Remote Control Æ ETHERNET 5–8 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A ADDRESS GATEWAY SNMP MAC = 00-06-B0-00-02-D9 Use the [←][→] arrow keys to select ADDRESS, GATEWAY, or SNMP, and then press [ENT]. The MAC Address is set at the factory and is read‐only. When ADDRESS is selected: IP Address/Range: 192.168.001.004/24 To edit the IP Address and Range for the Ethernet M&C port for this unit: Use the [←][→] arrow keys to select a digit to edit, and then use the [↑][↓] arrow keys to change its value. Press [ENT] when done. Press [ENT] when done. When GATEWAY is selected: Ethernet IP Gateway: 192.168.001.005 To edit the IP Gateway Address for the Ethernet M&C port for this unit: Use the [←][→] arrow keys to select a digit to edit, and then use the [↑][↓] arrow keys to change its value. Press [ENT] when done. When SNMP is selected: COMMUNITIES TRAPS Use the [←][→] arrow keys to select COMMUNITIES or TRAPS, and then press [ENT]. CONFIG: ETHERNET Æ SNMP Æ COMMUNITIES SNMP Communities: READ WRITE TRAP Use the [←][→] arrow keys to select READ, WRITE or TRAP, and then press [ENT]. When READ is selected: Read Community: Public 5–9 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A To edit the SNMP Read Community string: Use the [←][→] arrow keys to select a character to edit, and then use the [↑][↓] arrow keys to change that character. Only the first 20 characters on the bottom line are available. All printable ASCII characters are available with the exception of the backslash (ASCII code 92) and ~ (ASCII code 126). Press [ENT] once the string has been composed. All trailing spaces are removed from the Read Community string upon entry. When WRITE is selected: Write Community: Private To edit the SNMP Write Community string: Use the [←][→] arrow keys to select a character to edit, and then use the [↑][↓] arrow keys to change that character. Only the first 20 characters on the bottom line are available. All printable ASCII characters are available with the exception of the backslash (ASCII code 92) and ~ (ASCII code 126). Press [ENT] once the string has been composed. All trailing spaces are removed from the Write Community string upon entry. When TRAP is selected: Trap Community: comtech To edit the SNMP Traps Community string: Use the [←][→] arrow keys to select a character to edit, and then use the [↑][↓] arrow keys to change that character. Only the first 20 characters on the bottom line are available. All printable ASCII characters are available with the exception of the backslash (ASCII code 92) and ~ (ASCII code 126). Press [ENT] once the string has been composed. All trailing spaces are removed from the Trap Community string upon entry. 5–10 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A CONFIG: ETHERNET Æ SNMP Æ TRAPS TRAPIP1 TRAPIP2 VERSION Use the [←][→] arrow keys to select TRAPIP1, TRAPIP2 or VERSIONS, and then press [ENT]. When TRAPIP1 or TRAPIP2 is selected: Trap IP Address #X: 000.000.000.000 (Where X = 1 or 2) To edit the Trap Destination IP Address: Use the [←][→] arrow keys to select a digit to edit, and then use the [↑][↓] arrow keys to change its value. Press [ENT] when done. When VERSION is selected: Trap Version: SNMPv1 SNMPv2 Use the [←][→] arrow keys to select the Trap Version as SNMPv1 or SNMPv2, and then press [ENT]. 5.2.1.3 CONFIG: REDUND (Redundancy) Redundancy: Mode State FrcBkup Appendix B. LBC‐4000 REDUNDANCY OPERATION 5–11 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.2.1.4 Revision 2 MN-LBC4000A CONFIG: REFADJ (Reference Oscillator Adjustment) Reference frequency Adjustment = 087 The reference oscillator adjustment may be manipulated with this menu. Use the [←][→] arrow keys to select a digit to edit, and then the [↑][↓] arrow keys to change its value. Press [ENT] when done. The default Reference Frequency tuning adjustment is 087, with allowable values from 0 to 255. When an external reference oscillator is connected and set to 10 MHz the following screen appears: EXTERNAL 10 MHZ REFERENCE PRESENT When an external reference oscillator is connected and set to 5 MHz the following screen appears: EXTERNAL 5 MHZ REFERENCE PRESENT When an external reference oscillator is connected and set to other than 5 MHz or 10 MHz the following screen appears: EXTERNAL REFERENCE FREQ MUST BE 5/10 MHz 5.2.1.5 CONFIG: SPECT-INV (Spectrum Inversion) Spectrum Inversion: ConvA=NRM ConvB=INV To set Spectrum Inversion operation: Use the [←][→] arrow keys to select ConvA or ConvB, and then use the [↑][↓] arrow keys to toggle the parameter as NRM (Normal) or INV (Invert). Press [ENT] when done. 5–12 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.2.2 Revision 2 MN-LBC4000A MONITOR Use the[↑][↓] arrow keys to view monitor menu choices shown. For all read‐only Monitor displays, press [ENT] or [CLR] to return to the previous menu. The following table identifies each read‐only display available from the Monitor menu branch, including a sample screen and a functional description of the display: Submenu Example Conv-A Monitor A: rflo=01.6 iflo=08.2 tp=+32.1 Conv-B Monitor B: rflo=01.6 iflo=08.1 tp=+30.2 RefOsc Description For Converter Unit A or B: The operating parameters for the selected Up/Downconverter IDU are shown, where: iflo = IF Lockout rflo = RF Lockout tp = Operating Temp (°C) The raw voltage of the voltage tuning monitor is shown. MON Ref Osc: Vtune=04.7 Note: This display is used for debugging purposes only. PwrSupA Monitor PS A: 8V=08.2 12V=12.3 5V=05.3 PwrSupB Monitor PS B: 8V=08.1 12V=12.2 5V=05.3 5–13 Where ‘X’ denotes Power Supply ‘A’ or ‘B’: The 12V, 8V, and 5V values for the selected power supply are shown. LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.2.3 Revision 2 MN-LBC4000A FAULTS CURRENT STORED Use the [←][→] arrow keys to select the CURRENT or STORED faults, and then press [ENT]. 5.2.3.1 FAULTS: CURRENT Use the[↑][↓] arrow keys to scroll between and view the available lists of current faults. For all read‐only Fault displays, press [ENT] or [CLR] to return to the previous menu. The following table identifies each read‐only display available from the FAULTS: CURRENT menu branch, including a sample screen and a functional description of the display: 5.2.3.2 Submenu Example Description Conv-A Faults: Conv-A iflo=OK rflo=OK temp=OK For Converter Unit A or B: The faults for the selected Up/Downconverter IDU are shown, where: Conv-B Faults: Conv-B iflo=OK rflo=OK temp=OK iLO = IF Lock Fault rLO = RF Lock Fault Tp = Oper Temp (°C) Fault PwrSupA Monitor PS A: 8V=OK 12V=OK 5V=OK PwrSupB Monitor PS B: 8V=OK 12V=OK 5V=OK Ext RefOsc Faults: Ext Ref Ext Ref = FT The 12V, 8V, and 5V faults for the selected power supply are shown. The external reference oscillator fault menu FAULTS: STORED VIEW CLEAR-ALL Use the [←][→] arrow keys to select VIEW or CLEAR‐ALL, and then press [ENT]. FAULTS: STORED Æ VIEW Fault No. 06 10:28:53 OK-IFLO_A 08/10/04 5–14 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A A total of 100 faults can be stored in memory as they occur, and the faults are date and time stamped. The stored faults remain in memory until a CLEAR‐ALL command is entered. When the number of faults reaches 100, the 100th fault will display an error (ER). FAULTS: STORED Æ CLEAR-ALL Clear all stored Faults No Yes Upon selecting CLEAR‐ALL, you are prompted to choose No or Yes. Use the [←][→] arrow keys to select your choice, and then press [ENT]. By selecting Yes, the event log is cleared and you are then returned to the previous menu. However, if there are faults present on the unit at this time, they will be re‐time‐stamped, and new log entries will be generated. 5.2.4 UTILITY TIME DISP FIRMWARE AID LAMPTEST RELAY SCRSAVER Use the [←][→] arrow keys to select from the submenu choices shown, and then press [ENT]. The following table identifies each submenu available from the UTILITY menu branch – typical for Converter Unit A or Unit B – its content section in this chapter, and functional description of each submenu: Submenu Sect Functional Description TIME 5.2.4.1 Edits the date and Real-Time Clock time settings DISP 5.2.4.2 Adjusts the brightness level of the Vacuum Fluorescent Display (VFD) FIRMWARE 5.2.4.3 Displays and selects the installed internal firmware images AID 5.2.4.4 Use to enter an 48-character Application ID string (2 lines, 24 characters/line) LAMP-TEST 5.2.4.5 Runs a diagnostic test on each of the two sets of five front panel Light-Emitting Diodes (LEDs RELAY 5.2.4.6 Selects Fault Relay Logic SCRSAVER 5.2.4.7 Screen saver 5–15 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.2.4.1 Revision 2 MN-LBC4000A UTILITY: TIME Edit real-Time Clock: 11:59:13 12/02/08 To edit the time and date settings of the real‐time clock: Use the [←][→] arrow keys to select the digit to be edited, and then use the [↑][↓] arrow keys to change its value: • The time t= is entered in military format; that is, in the form hh:mm:ss (00‐23 hours:00‐ 59 minutes:00‐59 seconds). • The date d= is entered in mm/dd/yy format (01‐12 month/01‐31 day/00‐99 year). Press [ENT] when done. 5.2.4.2 UTILITY: DISP (Display Brightness) VFD Display Brightness: 100% To edit the display brightness: Use the [↑][↓] arrow keys to select a brightness value of 25%, 50%, 75%, or 100%. Press [ENT] when the brightness is suitable. 5.2.4.3 UTILITY: FIRMWARE Firmware Images: INFO SELECT This series of submenus permits you to view information about the LBC‐4000 internal firmware. The converter can store two complete firmware images, and you can select which image will be loaded the next time the unit reboots. Use the [←][→] arrow keys to select INFO or SELECT, and then press [ENT]. UTILITY: FIRMWARE Æ INFO Firmware Info: BOOTROM IMAGE#1 IMAGE#2 Use the [←][→] arrow keys to select BOOTROM, IMAGE#1 or IMAGE#2, and then press [ENT] to view the information. Typical for each screen, the firmware number, its version (e.g., 1.2.3 = FW Ver. 1.2.3) and the release date are provided. 5–16 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A When BOOTROM is selected: Bootrom: FW-0020506 #.#.# MM/DD/YY When IMAGE#1 OR IMAGE#2 Is selected: Image#x: BULK APP FPGA (Where Image#x denotes Image#1 or Image#2) Each selection is further broken down. Use [←][→] arrow keys to select BULK, APP, or FPGA, and then press [ENT] to view the information, formatted as per the BOOTROM firmware display screen. UTILITY: FIRMWARE Æ SELECT Current Active Image: Next Reboot Image: #1 #1 #2 The top line shows the current active image. On the bottom line, to elect the image that will be active the next time the unit is rebooted, use the [←][→] arrow keys to select #1 or #2. Press [ENT] when done. 5.2.4.4 UTILITY: AID (Application ID) --USER APPLICATION ID-- To create a 48‐character Application ID string: Use the [←][→] arrow keys to select a character to edit, and then use the [↑][↓] arrow keys to change that character. All printable ASCII characters are available with the exception of the backslash (ASCII code 92) and ~ (ASCII code 126). Note that each line is limited to 24 characters. Press [ENT] once the string has been composed. 5–17 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation 5.2.4.5 Revision 2 MN-LBC4000A UTILITY: LAMP-TEST (Front Panel LED Test) Once LAMP‐TEST is selected, the LBC‐4000 runs a diagnostic pass on the front panel LEDs. While the test is underway, the following message displays: Lamp Test In Progress Please Wait During the test, each converter LED group (CONV A and CONV B) illuminates in sequence: COLOR LED (CONVA / CONVB) RED SUM FLT YELLOW MUTE ON LINE GREEN UP DN 5.2.4.6 UTILITY: Relay FAULT RELAY LOGIC Normal Use the [↑][↓] arrow keys to select the Fault Relay Logic as Normal or Invert, and then press [ENT]. 5.2.4.7 UTILITY: SCRSAVER ScreenSaver: Theme=Classic Time=015m If you were to display the same screen for weeks at a time, the display could become ‘burnt’ with this image. To prevent this, the LBC‐4000 ‘screen saver’can be set to activate after a user‐ selected timeframe. Use the [←][→] arrow keys to select Theme or Time, and then press [ENT]. UTILITY: SCRSAVER Æ Theme Five screen saver themes are selectable. Each theme establishes a unique behavior for the screen saver when activated. Use the [↑][↓] arrow keys to select a theme, and then press [ENT] when done. Pressing any key will de‐activate the screen saver and restore the previous screen. 5–18 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Revision 2 MN-LBC4000A Note the following: Theme Name Classic Screen Saver Activity Visual ser Application ID-ress Any Key... Zip-ped Comtech EF Data LBC-4000 Cycling cation ID-----BC-4000... B-Board Comtech EF Data LBC-4000 S-Wiper Pass 1: Comtech EF Data LBC-4000 Pass 2: Screen-Saver Mode Press Any Key Description The top line of the display shows the user-defined “Application ID”, and the bottom line shows ‘Press any key...’. The message moves from right to left across the screen, and then wraps around. This mode features a ‘marquee’ display: “Comtech EF Data LBC-4000” This display ‘zips to center’ from ‘offstage right’ then ‘zips/exits offstage right.’ A single line display comprised of the user-defined “Application ID” and “LBC-4000” ‘crawls’ along from right to left across the top line of the VFD, and then wraps around to the bottom line, moving left to right as it ‘crawls off’ the display. This mode features a ‘marquee’ display: “Comtech EF Data LBC-4000” The display performs a ‘slow reveal’ from left to right, and then performs a ‘slow wipe’, again from left to right. This mode features two separate ‘marquee’ displays - the first reads, “Comtech EF Data LBC-4000” The second ‘marquee’ reads, “Screen-Saver Mode Press Any Key” The screens alternate, with Marquee 1 performing a slow reveal/wipe from left-to-right, and then Marquee 2 performs a slow reveal/wipe from right-to-left. UTILITY: SCRSAVER Æ Time The time lapse from normal VFD operation to screen saver mode may be adjusted – or disabled outright. Select OFF to disable the screen saver feature, or use the [↑][↓] arrow keys to select a time in minutes ranging from 001 to 999. Press [ENT] when done. 5–19 LBC-4000 L-Band Up/Down Converter System with Ethernet Front Panel Operation Notes: 5–20 Revision 2 MN-LBC4000A Chapter 6. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT 6.1 Introduction Ethernet‐based Remote Product Management of the LBC‐4000 L‐Band Up/Down Converter System with Ethernet is available using the rear panel ‘10/100 ETHERNET’ port. To proceed with Ethernet‐based Remote Product Management, assumptions are made that: • The LBC‐4000 is operating with the latest version firmware files. • The LBC‐4000 is connected to a user‐supplied Windows‐based PC as follows: o o o The PC’s serial port is connected to the LBC‐4000 rear panel ‘J1 | COM1’ port with a user‐supplied serial cable. The PC’s Ethernet port is connected to the LBC‐4000 rear panel ‘10/100 ETHERNET’ port with a user‐supplied hub, switch, or direct Ethernet cable connection. The PC is running a terminal emulation program (for operation of the LBC‐4000 serial remote control interface) and a compatible web browser (for operation of the LBC‐4000 Web Server (HTTP) Interface). • The LBC‐4000’s Management IP Address has been noted using the LBC‐4000 Front Panel. The sections that follow describe the functionality of the LBC‐4000 Ethernet Management Interface. See Chapter 5. FRONT PANEL OPERATION or the Remote Commands Specifications tables found in Chapter 7. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for detailed descriptions of many of the functions depicted throughout Sect. 6.4.5 Web Server Page Descriptions. 6–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.1.1 Revision 2 MN-LBC4000A Ethernet Management Interface Protocols For SNMP, Telnet, or HTTP operation, the LBC‐4000 must be configured with the Ethernet control option. Via the front panel, select CONFIG: Remote Control Æ Ethernet. See Chapter 5. FRONT PANEL OPERATION for further information. The user PC facilitates access to Ethernet‐based remote Monitor and Control (M&C) of the LBC‐4000 through three separately operated protocols: • Simple Network Management Protocol (SNMP). This requires a user‐supplied Network Management System (NMS) and a user‐supplied Management Information Base (MIB) File Browser. • Telnet Interface. This requires use of the user PC’s Command‐line interface, or a user‐ supplied terminal emulation program such as HyperTerminal. • LBC‐4000 Web Server (HTTP) Interface. This requires a compatible user‐supplied web browser such as Internet Explorer. 6–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.2 Revision 2 MN-LBC4000A SNMP Interface The Simple Network Management Protocol (SNMP) is an Internet‐standard protocol for managing devices on IP networks. An SNMP‐managed network consists of three key components: • The managed device. This includes the LBC‐4000. • The SNMP Agent. The software that runs on the LBC‐4000. The LBC‐4000 SNMP Agent supports both SNMPv1 and SNMPv2c. • The user‐supplied Network Management System (NMS). The software that runs on the manager. 6.2.1 Management Information Base (MIB) Files MIB files are used for SNMP remote management of a unique device. A MIB file consists of a tree of nodes called Object Identifiers (OIDs). Each OID provides remote management of a particular function. These MIB files should be compiled in a user‐supplied MIB Browser or SNMP Network Monitoring System server. The following MIB files are associated with the LBC‐4000: MIB File/Name (where ‘x’ is revision letter) FW-0000235x.mib ComtechEFData Root MIB file 6.2.2 Description ComtechEFData MIB file gives the root tree for ALL Comtech EF Data products and consists of only the following OID: Name: comtechEFData Type: MODULE-IDENTITY OID: 1.3.6.1.4.1.6247 Full path: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtechEFData(6247) Module: ComtechEFData FW-0020542.mib LBC-4000 MIB file MIB file consists of all of the OID’s for management of the amplifier functions FW-0020543.mib LBC-4000 Traps MIB file Trap MIB file is provided for SNMPv1 traps common for LBC-4000. SNMP Community Strings In SNMP v1/v2c, the SNMP Community String is sent unencrypted in the SNMP packets. Caution must be taken by the network administrator to ensure that SNMP packets travel only over a secure and private network if security is a concern. The LBC‐4000 uses Community Strings as a password scheme that provides authentication before gaining access to the LBC‐4000 agent’s MIBs. They are used to authenticate users and determine access privileges to the SNMP agent. 6–3 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A Type the SNMP Community String into the user‐supplied MIB Browser or Network Node Management software. You may define three Community Strings for SNMP access: • Read Community default = public • Write Community default = private • Trap Community default = comtech For proper SNMP operation, the LBC‐4000 MIB files must be used with the associated version of the LBC‐4000 Remote Router M&C. Refer to the LBC‐4000 FW Release Notes for information on the required FW/SW compatibility. 6.2.3 SNMP Traps The LBC‐4000 supports both SNMPv1 traps and SNMPv2 notifications. The LBC‐4000 has the ability to send out SNMP traps when certain faults occur in the unit. A trap is sent both when a fault occurs and when a fault clears. Which style of traps the LBC‐4000 sends can be configured using the LBC‐4000SNMPTrapVersion OID. MIB2 SNMPv1traps and SNMPv2 notifications are supported by the LBC‐4000. 6–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.3 Revision 2 MN-LBC4000A Telnet Interface The LBC‐4000 provides a Telnet interface for the purpose of Equipment M&C via the standard equipment Remote Control protocol. The Telnet interface requires user login at the Administrator level and Read/Write level. An example of the login process is shown here: Once logged into the Telnet interface as Administrator, you can access the standard remote control interface defined in Chapter 7. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT. 6.3.1 Telnet Operation via HyperTerminal There is a disadvantage when using Windows Command‐line as a Telnet client. Since Command‐ line cannot translate a ‘\r’ (i.e., carriage return or “CR”) to a ‘\r\n’ (i.e., CR+line feed “LF”) for the messages coming from Telnet Server, any multi‐line Target‐to‐Controller response (e.g., the response to the FRW? query) will be displayed as one line, with the latter lines overwriting the previous lines. In order to view the full response messages, Comtech EF Data recommends use of the HyperTerminal terminal emulation program, configured as a Telnet client. Configure HyperTerminal as follows: 1. Ensure that the connection is made using TCP/IP (Winsock) instead of COM1 or COM2, as shown at the near right. 2. ASCII Setup (File Æ Properties Æ Settings Æ ASCII Setup): Check the "Send line ends with line feeds" option in the ASCII Sending section, and the "Append line feeds to incoming line ends" option in the ASCII Receiving section, as shown at the far right. 6–5 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A An example of login and remote command/query execution, when using HyperTerminal as the interface, is shown here: 6–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4 Revision 2 MN-LBC4000A Web Server (HTTP) Interface A user‐supplied web browser allows the full monitor and control (M&C) of the LBC‐4000 through its Web Server Interface. This embedded web application is designed for, and works best with, Microsoft’s Internet Explorer Version 5.5 or higher (the examples shown use Internet Explorer Version 7.0). See Chapter 5. FRONT PANEL OPERATION or the Remote Commands Specifications tables found in Chapter 7. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for detailed descriptions of many of the functions depicted throughout Sect. 6.4.5 Web Server Page Descriptions. 6.4.1 Enabling the Web Server Interface The IP Address can be verified from the front panel menus: CONFIG: Remote Control Æ Ethernet Æ Address. See Chapter 5. FRONT PANEL OPERATION for complete details about using this M&C interface. To enable the Web Server Interface in the LBC‐4000 using only a 100BaseTx remote interface (this assumes you are running Microsoft Windows OS): 1. Select Start, then Run, then type “cmd” to open the command prompt window: 2. Start a Telnet session with the unit at the default IP address of 192.168.1.4: 3. Enter the Telnet username and password (the default for both parameters is comtech): Failure to enter the correct User name and Password will return you to a blank login screen. 6–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.2 Revision 2 MN-LBC4000A User Login 1. From the PC, type http://192.168.1.4 (the default IP address for the LBC‐4000) into the Address area of the browser: 2. At the prompt, type in a valid User name and Password, similar to the dialog box shown to the right. For all interfaces, the default for both is comtech. Type the User name and Password, and then click [OK]. Failure to enter the correct User name and Password will return you to the Login window. Should you continue to specify an invalid User name or Password, the message “You do not have security privilege to access this area.” displays. Otherwise, upon entry of the valid IP address and login information LBC‐4000 Web Server Interface “splash” page displays, similar to the example shown here: 6–8 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.3 Revision 2 MN-LBC4000A Web Server Interface – Operational Features 6.4.3.1 Navigation This manual uses a naming format for all Web Server Interface pages to indicate the depth of navigation needed to view the referenced page: “Top Level Tab | HTTP Page Hyperlink.” For example: “Home | Support” is interpreted to mean “first click the top‐level ‘Home’ navigation tab; then, click the ‘Support’ page hyperlink. Roll the cursor over the navigation tabs located at the top of each page, and then select from the available hyperlinks. 6.4.3.2 Page Sections Each page is divided into operational content sections. Whether there is one section to a page, or there are multiple sections, the title at the upper‐left corner of each page and its sections provide a reference to its operational features. See Chapter 5. FRONT PANEL OPERATION or the Remote Commands Specifications tables found in Chapter 7. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for detailed descriptions of many of the functions depicted throughout Sect. 6.4.5 Web Server Page Descriptions. 6.4.3.3 Execution Buttons Configuration changes generally do not take effect until a selection has been saved to Flash memory. There may be anywhere from one execution button per page up to multiple execution buttons within a page section. The label for each of these buttons is generally self‐explanatory, e.g., [Submit], [Clear], [Refresh], etc. All execution buttons serve the same purpose – to save the configuration changes to Flash memory, or to execute an update of the active page display. Always make sure to click the execution button before selecting another page. Any changes made on that previous page will not be saved if the execution button for those functions is not clicked. 6–9 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.3.4 Revision 2 MN-LBC4000A Feature Selection Drop‐down menus provide access to multiple setting selections, where available, for a specific function. Move the cursor to the drop‐down tab, and then left‐click the tab. The drop‐down will open and list the available selections. Move the cursor to the desired choice and then left‐click once again to select that choice. 6.4.3.5 Text or Data Entry Text boxes are provided any time an alphanumeric entry is required for access or configuration. Move the cursor to the text box, and then left‐click anywhere inside the box. Then, use the keyboard to type in the desired alphanumeric string. Press Enter when done. 6.4.4 Web Server Interface – Menu Tree The options available through the LBC‐4000 Web Server Interface are illustrated via the following menu tree: Home Admin Config Status Home Access Conv A Summary Contact SNMP Conv B Faults Support Ref Utility Redundancy Serial This interface provides access to four navigation tabs (shown in blue): • Home • Admin (Administration) • Config (Unit Configuration) • Stats (Status) Beyond the top‐level row of navigation tabs, the diagram illustrates the available nested hyperlinks (shown in grey) that afford more specific user functionality. Click any tab or hyperlink to continue. 6–10 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A 6.4.5 Web Server Interface – Page Descriptions The sections and subsections that follow detail the web pages accessible via hyperlink from the top‐level page navigation tabs shown in Sect. 6.4.4: • Sect. 6.4.5.1 Home Pages • Sect. 6.4.5.2 Admin (Administration) Pages • Sect. 6.4.5.3 Config (Configure LBC‐4000) Pages • Sect. 6.4.5.4 Status Pages 6.4.5.1 Home Pages Select the Home, Contact, or Support hyperlink to continue. 6.4.5.1.1 Home | Home From any location within the LBC‐4000 Web Server Interface, click the Home top navigation tab and/or the nested hyperlink to return to this top‐level page. Use this page to identify the product and its current operating firmware version. Figure 6-1. Home | Home page 6–11 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.1.2 Revision 2 MN-LBC4000A Home | Contact Use this page to reference the basic contact information needed to reach Comtech EF Data Sales and Customer Support via phone, fax, or web/e‐mail hyperlinks. Figure 6-2. Home | Contact page 6–12 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.1.3 Revision 2 MN-LBC4000A Home | Support For this page to operate correctly, the modem’s administrator is required to specify the SMTP server, domain name, and destination on the Admin | Access page (see Sect. 6.4.5.2.1). This page uses SMTP (Simple Mail Transport Protocol) to compose and send an e‐mail message to Comtech EF Data Modem Support ([email protected]). Use this communications portal for questions about or problems with the modem. Figure 6-3. Home | Support page Contact Information Use this section to provide your contact information to Comtech EF Data. Problem Report Use this section to compose the required message – up to 256 characters maximum are permitted. Once the desired message is created (and the pertinent Contact Information has been filled in), click [Submit Email] to send the message. 6–13 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.2 Revision 2 MN-LBC4000A Admin Pages As required to enable communication with the LBC‐4000 Web Server Interface, the Administrator may use these pages to set up user names; passwords; the e‐mail server; and the host IP Addresses The Admin pages are available only to users who have logged in using the Administrator Name and Password. Click the Access or SNMP hyperlink to continue. 6.4.5.2.1 Admin | Access Use this page to set up and maintain user names, passwords, the e‐mail server, and the host IP addresses to facilitate communication with the LBC‐4000 Web Server Interface. Figure 6-4. Admin | Access page Network Maintenance • IP Gateway, IP Address/Range: Enter the desired IP Gateway Address and IP Address/ Range in these text boxes. • MAC Address (read‐only): The MAC is set at the factory to a guaranteed unique address that cannot be modified by the user. 6–14 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A Click [Change IP Address] to save these changes. If you wish to revert to the previously assigned IP Gateway and IP Address/Range, click [Reset] instead. System Account Access Information • Admin, Read/Write, and Read Only Names and Passwords: The factory defaults for these names/passwords are: o Admin comtech/comtech o Read/Write opcenter/1234 o Read Only monitor/1234 Note the following: o These Name fields can be any alphanumeric combination with a maximum length of 10 characters. o These Password fields can be any alphanumeric combination with a maximum length of 10 characters. • • SMTP Server: Specify the mail server IP address from where you want to send the e‐mail. SMTP Domain Name / Destination: The Administrator can assign the SMTP Domain Name and Destination. This is required if the e‐mail feature of the Home | Support page (Sect. 6.4.3.1.3) is to be used. o o For SMTP Domain Name, specify the domain of the e‐mail server (usually found to the right of the @ symbol in an e‐mail address). For SMTP Domain Destination, specify the e‐mail recipient name (usually found to the left of the @ symbol in an e‐mail address). Click [Submit Access] to save these changes. If you wish to revert to the previously assigned System Account Access Information, click [Reset] instead. To update the page with its latest operating parameters, click [Refresh]. 6–15 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.2.2 Revision 2 MN-LBC4000A Admin | SNMP Use this page to set and returns administration information for the LBC‐4000 Simple Network Management Protocol (SNMP) feature. Figure 6-5. Admin | SNMP page SNMP • • Simple Network Management Operational Status: Use the drop‐down menu to select the Simple Network Management operational setting as Enabled or Disabled. The SNMP Read and Write Community String fields can be any combination of characters and a length of 0 ‐ 20 characters: o o • • • The factory default for the Read Community String parameter is public. The factory default Write Community String is private. Enable Authentication Trap: Use the drop‐down menu to select the Enable Authentication Trap operational setting as Enabled or Disabled. The Administrator can assign up to two SNMP Trap IP addresses and one SNMP Trap Community String. The SNMP Trap Community String field can be any combination of characters and a length of 0 ‐ 20 characters: o The factory default for the Trap Community String is comtech. Trap Version: Use the drop‐down menu to select the SNMP Trap Version as SNMPv1 or SNMPv2. For details pertaining to the remaining configuration parameters available on this page, see Sect. 6.3 SNMP INTERFACE. 6–16 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A Click [Submit SNMP] to save these changes. If you wish to revert to the previously assigned SNMP designations, click [Reset] instead. To update the page with its latest operating parameters, click [Refresh]. 6–17 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.3 Revision 2 MN-LBC4000A Config Pages Select the ConvA, ConvB, Ref, Utility, Redundancy, or Serial hyperlink to continue. 6.4.5.3.1 Config | ConvA / Conv B Use these pages to configure the communications, operations, and alarms/faults handling for LBC‐4000 Converter A or B. Figure 6-6. Config | ConvA and ConvB pages 6–18 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A Converter A / Converter B • Frequency in MHz: Enter an operating RF Frequency (if the converter is a Ku‐Band down converter) in the range of 10950 to 12750 MHz. Otherwise, this field will display as N/A. • Attenuation (dB): Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps. • Attenuation Offset (ConvA page only): Enter a valid value, in dB, for the attenuation offset. Click [Change Configuration] to save these changes. If you wish to revert to the previously assigned parameters, click [Reset] instead (ConvB page only). Mute Use the drop‐down menu to select Configuration Mute Mode as On or Off, and then click [Change]. Carrier Mute Mode Use the drop‐down menu to select the Carrier Mute function as On or Off, and then click [Change]. Slope Enter a slope value (0.0 to 1.0) in 0.1 steps. Click [Change] when done. Spectrum Inversion Use the drop‐down menu to select the Spectrum Inversion function as INV or NRM (Normal), and then click [Change]. Click [Submit SNMP] to save these changes. 6–19 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.3.2 Revision 2 MN-LBC4000A Config | Ref Use this page to review the operational parameters of, and to adjust, the reference oscillator. Figure 6-7. Config | Ref page Reference Oscillator • • • • External Reference Freq. (read‐only) – When an external reference oscillator is connected, its operational value (i.e., 5 MHz or 10 MHz) is displayed here. Reference Tuning (VDC) (read‐only) – The currently defined Reference Frequency tuning adjustment is displayed here. External Reference Lock (read‐only) – The External Reference Lock state is displayed here. Tuning Adjustment – Enter a numeric value for the reference oscillator tuning voltage here. The default value is 087, with allowable values from 0 to 255. Click [Submit] to save these changes. To update the page with the latest available values, click [Refresh]. 6–20 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.3.3 Revision 2 MN-LBC4000A Config | Utility Use this page to configure LBC‐4000 operating parameters. Figure 6-8. Config | Utility page Date Enter a date in the form MM/DD/YY (where MM = month [01 to 12], DD = day [01 to 31], and YY = year [00 to 99]). Time Enter a time in the form HH:MM:SS (where HH = hour [00 to 23], MM = minutes [00 to 59], and SS = seconds [00 to 59]). Click [Change Date/Time] to save these changes. Circuit ID Enter a Circuit ID string of up to 48 characters, and then click [Change CID] to save this change. Current Active Firmware Image (read-only) This section identifies the selected Current Active Firmware Image. In this example, Image 1 is the Current Active Firmware Image. 6–21 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A Next Reboot Image Use the drop‐down menu to select Image 1 or 2. Press [Submit] when done. Click [Reboot Now] to reboot the LBC‐4000 using the Current Active Firmware Image. Fault Relay Logic Use the drop‐down menu to select the Fault Relay Logic as Normal or Invert, and then click [Submit]. Perform Soft Reboot Click [Reboot Now] to reboot the LBC‐4000 using the Current Active Firmware Image. Firmware Information (read-only) This scrollable window identifies the Bootrom, Bulk Image#1 and Bulk Image #2 firmware information. To update the page with the latest available parameters, click [Refresh]. 6.4.5.3.4 Config | Redundancy Appendix B. LBC-4000 REDUNDANCY OPERATION. Use this page to configure the LBC‐4000’s Redundancy Switch Mode. Figure 6-9. Config | Redundancy page 6–22 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.3.5 Revision 2 MN-LBC4000A Config | Serial Use this page to configure LBC‐4000 operating parameters over the EIA‐485/232 serial interface. Figure 6-10. Config | Serial page Serial Use the drop‐down menu to select the operating serial mode as RS‐485 or RS‐232. Remote Address Enter a valid remote control address from 0001 to 9999. Baud Rate Use the drop‐down menu to select the operating baud rate as 100, 2400, 4800, 9600, 19200 or 38400 baud. Data bits – Parity – Stop Bits Use the drop‐down menu to select the asynchronous character format as 8‐N‐1 (8 data bits, no parity, 1 stop bit); 7‐O‐2 (7 data bits, odd parity, 2 stop bits); or 7‐E‐2 (7 data bits, even parity, 2 stop bits). Click [Change Serial Configuration] to save these changes. To update the page with the latest available parameters, click [Refresh]. 6–23 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.4 Revision 2 MN-LBC4000A Status Pages The hyperlinks available under the ‘Status’ tab provide access to operational statistics, status windows, and a logged fault table. Click the Summary or Faults hyperlink to continue. 6.4.5.4.1 Status | Summary Use this read‐only page to review pertinent information about the configured setup of the LBC‐4000, its current operating parameters, and the operational status of the unit. Figure 6-11. Status | Summary page Typical for all sections, when operating parameters are within acceptable limits for any item, the STATUS indicates OK within a green box. If a fault condition exists, the message box changes to red with the FAULT indicated accordingly. Parameter Status section Product identification (i.e., CID, serial and model numbers), active firmware, software image information, and other operational configuration information is provided here. 6–24 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management Revision 2 MN-LBC4000A Converter A / Converter B Status section This section identifies the converter installed in each module slot (BUC or BDC) and each module’s associated RF conversion band and frequency, attenuation value, mute status, and online/offline status. Converter A / B, Power Supply A / B Monitor and Status section This section provides the current monitored value for each module (BUC or BDC), including the RF/IF lockout status, operating voltages and temperatures. The operating voltages for each power supply are also provided. Note the following: • Valid Converter A/Converter B LNA Current readings are provided only if the pertinent LBC‐4000 Down Converter (BDC) is optionally configured with an LNA. These parameters otherwise will display as N/A if the pertinent converter is a BUC. • Valid Converter A/Converter B Forward RF Power readings are provided only if the pertinent LBC‐4000 up converter (BUC) is optionally configured with the Power Monitor feature. These parameters otherwise will display as N/A if the pertinent converter is a BDC. • Valid Power Supply 2 and Local Switch Position information is provided with redundant configurations only. To update the page with the latest available parameters, click [Refresh]. 6–25 LBC-4000 L-Band Up/Down Converter System with Ethernet Ethernet-based Remote Product Management 6.4.5.4.2 Revision 2 MN-LBC4000A Status | Faults Use this read‐only page to review the LBC‐4000’s current logged operating faults. Figure 6-12. Status | Faults page Unread Stored Faults: ### This read‐only section features a scrollable window that displays the unread stored faults log in sequential, date‐stamped format. In the section header, ### denotes the running tally of unread stored faults. The unit returns and displays the five oldest stored faults in the alarm log. All faults that are read from the log are automatically removed from the tally. You can manage the Unread Stored Faults window as follows – select a choice, and then click [Submit] to execute the update to the window: • Read Next Five Faults: Select to display the next five unread stored faults in the log. • Clear Fault Log: Select to clear all stored faults from the log. • Initialize Faults Pointer: Select to reset the internal pointer to allow queries to start at the beginning of the stored faults log. To update the page with the latest available faults, click [Refresh]. 6–26 Chapter 7. SERIAL-BASED REMOTE PRODUCT MANAGEMENT 7.1 Introduction Serial‐based Remote Product Management of the LBC‐4000 L‐Band Up/Down Converter System is available using the rear panel ‘J1 COM1’ port. This interface is either an EIA‐485 multi‐drop bus (for the control of many devices) or an EIA‐232 connection (for the control of a single device), and data is transmitted in asynchronous serial form, using ASCII characters. Control and status information is transmitted in packets of variable length, in accordance with the structure and protocol defined in later sections. 1. To proceed with Serial‐based Remote Product Management, assumptions are made that: • The LBC‐4000 is operating with the latest version firmware files. • The LBC‐4000 is connected to a user‐supplied Windows‐based PC as follows: o The PC serial port is connected to the LBC‐4000 rear panel ‘J1 | COM1’ port with a user‐supplied serial cable. o The PC is running a terminal emulation program (for operation of the LBC‐4000 serial remote control interface). 2. See Chapter Sect. 3.2.2.4 J1 | COM 1 (EIA‐485/232) Interface Connector (DB‐9F) for the serial interface connector pinout information. 7–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management 7.1.1 Revision 2 MN-LBC4000A EIA-485 For applications where multiple devices are to be monitored and controlled, a full‐duplex (4‐wire plus ground) EIA‐485 is preferred. Half‐ duplex (2‐wire plus ground) EIA‐485 is possible, but is not preferred. In full‐duplex EIA‐485 communication, there are two separate, isolated, independent, differential‐mode twisted pairs, each handling serial data in different directions. It is assumed that a 'Controller' device (a PC or dumb terminal) transmits data in a broadcast mode via one of the pairs. Many 'Target' devices are connected to this pair, and all simultaneously receive data from the Controller. The Controller is the only device with a line‐ driver connected to this pair; the Target devices have only line‐receivers connected. In the other direction: On the other pair, each Target has a Tri‐state line driver connected; the Controller has a line‐receiver connected. All the line drivers are held in high‐impedance mode until one – and only one – Target transmits back to the Controller. Each Target has a unique address; each time the Controller transmits, the address of the intended recipient Target is included in a framed 'packet' of data. All of the Targets receive the packet, but only one (the intended) will reply. The Target enables its output line driver and transmits its return data packet back to the Controller in the other direction on the physically separate pair. EIA‐485 (full duplex) summary: • Two differential pairs – one pair for Controller‐to‐Target, one pair for Target‐to‐Controller. o The Controller‐to‐Target pair has one line driver (Controller), and all Targets have line‐receivers. o The Target‐to‐Controller pair has one line receiver (Controller), and all Targets have Tri‐state drivers. 7.1.2 EIA-232 This is a much simpler configuration in which the Controller device is connected directly to the Target via a two‐wire‐plus‐ground connection. Controller‐to‐Target data is carried, via EIA‐232 electrical levels, on one conductor, and Target‐to‐Controller data is carried in the other direction on the other conductor. 7–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management 7.2 Remote Commands and Queries Overview 7.2.1 Basic Protocol Revision 2 MN-LBC4000A Whether in EIA‐485 or EIA‐232 mode, all data is transmitted as asynchronous serial characters, suitable for transmission and reception by a UART. The asynchronous character format is 8‐N‐1 (8 data bits, no parity, one stop bit). The supported baud rates are 1200, 2400, 4800, 9600, 19K2 (19200), or 38K4 (38400) bps. All data is transmitted in framed packets as asynchronous serial characters, suitable for transmission and reception to the Controller using a universal asynchronous receiver/transmitter (UART). Controller‐to‐Target data is carried via EIA‐232 electrical levels on one conductor, and Target‐to‐Controller data is carried in the other direction on the other conductor: • Controller‐to‐Target – The Controller device (e.g., the user PC) is used to transmit instructions (commands) to – or to request information from (queries) – the Target device (i.e., the LBC‐4000). • Target‐to‐Controller – The Target, in return, only transmits response information to the Controller when specifically directed by the Controller. For Serial Remote Control, all issued commands (Controller‐to‐Target) require a response (Target‐to‐Controller). This response is either to return data that has been queried by the Controller, or to confirm the Target’s receipt of a command to change the Target’s configuration. 7.2.2 Packet Structure The exchange of information is transmitted, Controller‐to‐Target and Target‐to‐Controller, in packets. Each packet contains a finite number of bytes consisting of printable ASCII characters, excluding ASCII code 127 (DELETE). In this context, the Carriage Return and Line Feed characters are considered printable. All messages from Controller‐to‐Target require a response, with one exception: This will be either to return data that has been requested by the Controller, or to acknowledge reception of an instruction to change the configuration of the Target. The exception to this is when the Controller broadcasts a message (such as Set Time/Date) using Address 0, when the Target is set to EIA‐485 mode. 7–3 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Revision 2 MN-LBC4000A Controller-to-Target (Issued Command or Query) Start of Packet Target Address Address Delimiter < ASCII code 60 0000 (default) / ASCII code 47 (1 character) (4 characters) (1 character) Packet Example: Instruction Code Code Qualifier Optional Arguments = or ? ASCII codes 61 or 63 (3 characters) (1 character) End of Packet Carriage Return ASCII code 13 (n characters) (1 character) Optional Arguments End of Packet <0000/RSH=30[cr] Target-to-Controller (Response to Command or Query) Start of Packet Target Address Address Delimiter > ASCII code 62 0000 (default) / ASCII code 47 (1 character) (4 characters) (1 character) Instruction Code Code Qualifier = or ? ASCII codes 61 or 63 (3 characters) (1 character) Carriage Return ASCII code 13 (n characters) (1 character) Packet Example: >0000/BBU=107[cr][lf] Detailed description of the packet components follow. 7.2.2.1 • Start of Packet Controller‐to‐Target – This is the character ‘<’ (ASCII code 60). Target‐to‐Controller – This is the character ‘>’ (ASCII code 62). • The ‘<’ and ‘>’ characters indicate the start of packet. They may not appear anywhere else within the body of the message. 7–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management 7.2.2.2 Revision 2 MN-LBC4000A Target Address Up to 9,999 devices can be uniquely addressed; in EIA‐485 applications, the permissible range of values is 1 to 9999. The address is programmed into a Target unit using the remote control port. Each block converter module has its own address: Module Address LBC-4000 Base Block Converter A Base + 1 Block Converter B Base + 2 If several devices share an EIA‐485 bus, it must be noted that the LBC‐4000 will require three addresses, and should be spaced apart accordingly. The Controller sends a packet with the address of a Target – the destination of the packet. When the Target responds, the address used is the same address, to indicate to the Controller the source of the packet. The Controller does not have its own address. 7.2.2.3 Address Delimiter This is the “forward slash” character '/ ' (ASCII code 47). 7.2.2.4 Instruction Code This is a three‐character alphabetic sequence that identifies the message subject. Wherever possible, the instruction codes have been chosen to have some significance – e.g., FRE for Operating FREquency, IPA for Management IP Address, etc. This aids in the readability of the message, should it be displayed in its raw ASCII form. Upper case and lower case alphabetic characters may be used (‘A’ to ‘Z’ and ‘a’ to ‘z’, ASCII codes 65‐90 and 97‐172). 7–5 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management 7.2.2.5 Revision 2 MN-LBC4000A Instruction Code Qualifier This is a single character that further qualifies the preceding instruction code. Code Qualifiers obey the following rules: From Controller‐to‐Target, the only permitted characters are: Character Definition = (ASCII code 61) This character is used as the Assignment Operator (AO). It establishes that the Instruction Code that precedes it is to be used as a command to assign or configure operation. The instruction set that follows serves to assign the Target’s new parameter setting or operational value. Example: From Controller-to-Target, MUT=1 means “enable the mute function.” ? (ASCII code 63) This character is used as the Query Operator (QO). It establishes that the Instruction Code that precedes it is to be used as a query that returns the Target’s current configured parameter setting or operational value. Example: From Controller-to-Target, MUT? means “what’s the current state of the MUTE function?” From Target‐to‐Controller, the only permitted characters are: Character Definition = (ASCII code 61) This character is used in two ways: a. If the Controller sends a query to the Target – for example: MUT? meaning “what’s the current state of the MUTE function?”, the Target would respond with MUT=x, where x represents the state in question: 1 being enabled, and 0 being disabled. b. If the Controller sends an instruction to set a parameter to a particular value, and the value sent is valid, the Target acknowledges the message and responds with MUT= (with no message arguments). ? (ASCII code 63) If the Controller sends an instruction to set a parameter to a particular value, and the value sent is not valid, the Target then acknowledges the message and responds with, for example, MUT? (with no message arguments). This indicates that there was an error in the message sent by the Controller. ! (ASCII code 33) If the Controller sends an instruction code that the Target does not recognize, the Target responds by echoing the invalid instruction, followed by ! Example: XYZ! 7–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management 7.2.2.6 Revision 2 MN-LBC4000A Character Definition * (ASCII code 42) If the Controller sends the command to set a parameter to a particular value, and the value sent is valid BUT the router will not permit that particular parameter to be changed at present, the Target acknowledges the message and responds with, for example, MUT* (with message arguments). # (ASCII code 35) If the Controller sends an instruction code which the Target cannot currently perform because of hardware resource issues, then the Target will acknowledge the message by echoing the invalid instruction, followed by the # character. This response can only occur if the operator sends two or more ‘hardware configuration’ type commands without allowing adequate time between commands for the hardware to be configured. For example, if the operator issued commands to change both the frequency and the attenuation with less than 100 milliseconds between commands, and if this response is returned, then the command has not been accepted and the operator must resend the command. $ (ASCII code 36) The Target acknowledges the message indicating that this block converter is not installed. Optional Message Arguments Arguments are not required for all messages. Arguments are ASCII codes for the characters ‘0’ to ‘9’ (ASCII codes 48 to 57), period ‘.’ (ASCII code 46), and comma ‘,’ (ASCII code 44). 7.2.2.7 • • End of Packet Controller‐to‐Target – This is the ‘Carriage Return’ ([CR]) character (ASCII code 13). Target‐to‐Controller – This is the two‐character sequence ‘Carriage Return’, ‘Line Feed’ ([cr][lf]) (ASCII codes 13 and 10). Both indicate the valid termination of a packet. 7–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management 7.3 Revision 2 MN-LBC4000A Remote Commands and Queries The table that follows provides a ‘quick reference‘ to the Instruction Codes available at present for M&C of the LBC‐4000. The ‘C’ and ‘Q’ columns, when marked with an ‘X’, denote whether that Instruction Code is Command Only, Query Only, or Command and Query. Instr Code AID ATO ATT CAA CAS CCS CMM CMS CUS DAT FBU FRE FRL FRW FRM C X X X Q X X X X X X X X X X X X X X X X X X X Page 7-9 7-9 7-9 7-9 7-10 7-10 7-11 7-11 7-12 7-12 7-12 7-12 7-12 7-13 7-19 Instr Code IMG C X Q X Page 7-18 LAA LRS X X X 7-13 7-18 MUT X X 7-13 ONL X 7-13 PNM_x X 7-19 RAS RCS RED REM RET RET_x RMS RUS X X X X X X X X X X 7-13 7-14 7-15 7-15 7-15 7-15 7-15 7-16 Instr Code SAM SAS SBR SPA SPI SRO SSA SSN C X Q X X X X X X X X Page 7-16 7-16 7-16 7-16 7-17 7-17 7-17 7-17 TIM X X 7-17 VFD X X 7-18 IPA IPG MAC IMG X X X X X X 7-18 7-18 7-18 7-18 X X X X X X NOTE – Instruction Code Qualifiers, as defined in Sect. 7.2.2.5, are used as follows in the command/query tables’ ‘Response to Command’ columns: = Message OK * Message OK, but not permitted in current mode ? Received OK, but invalid arguments found # Message OK, but unit is not in Remote mode ! Invalid instruction 7–8 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Application Identification Command (Instruction Code and Qualifier) AID_ Arguments for Command or Response to Query 48 bytes, alphanumeric Attenuation Offset ATO_A_SY.Z 6 bytes Alphanumeric Attenuation ATT_ 7 bytes, alphanumeric Clear All Stored Alarms CAA_ None Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Command or Query. Used to identify or name the unit or station, in the form AID_xxx…x where: • First line is limited to 24 characters. • Second line is also limited to 24 characters. • No carriage return between first line and second line. Example: AID_ --Earth Station 1— ---Converter #1---Command or Query. Used to control or query attenuation offset, in the form ATO_A_SY.Z <Enter> where: S=Sign (+ or -) Y=Number between 0 and 5 Z=Number between 0 and 9 (cannot be greater than 5.0) Example: ATO_A_+2.3 <Enter> = Command Notes: 1. Applicable only on Slot A. Slot B will return error. 2. If (displayed attenuation + offset) < 0, actual attenuation will be set to 0dB. 3. If (displayed attenuation + offset) > maximum attenuation, actual attenuation will be set to maximum attenuation. 4. Actual attenuation is the sum of Attenuation displayed on front panel and Offset. Command or Query. In the form ATT_x_yy.yy where: x = ‘A’ (Converter A) or ‘B’ (Converter B) yy.yy = Valid attenuation level, in dB, at 0.1dB step size as factory default. Example: ATT_A_12.20 (Converter A is set to 12.20 dB) Command only. Instructs the target to clear all Stored Events, in the form CAA_xxx, where: xxx = YES 7–9 Response to Command (Target to controller) Same as command Query (Instruction Code and qualifier) Response to query (Target to controller) AID_ AID_x…x (see Description of Arguments for details) ATO_A_SY.Z ATO_A_<Enter> (see Description of Arguments for details) Same as command ATT_x_ ATT_x_yy.yy (see Description of Arguments for details) CAA_CLEARED N/A N/A LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Concise Alarm Status Concise Configuration Status Command (Instruction Code and Qualifier) N/A N/A Arguments for Command or Response to Query 13 bytes numeric 52 bytes numeric Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Query only. Used to Query the Alarm Status of the unit, in the form CAS_abcdefghijklm’cr’’lf’, where: a = 1 if 12VDC #1 Fault, else 0. b = 1 if 8VDC #1 Fault, else 0. c = 1 if 5VDC #1 Fault, else 0. d = 1 if 12VDC #2 Fault, else 0. e = 1 if 8VDC #2 Fault, else 0. f = 1 if 5VDC #2 Fault, else 0. g = 1 if REF LD Fault, else 0. h = 1 if IFLO A Fault, else 0. i = 1 if RFLO A Fault, else 0. j = 1 if TEMP A Fault, else 0. k = 1 if IFLO B Fault, else 0. l = 1 if RFLO B Fault, else 0. m = 1 if TEMP B Fault, else 0. Query only. Used to query the summarized version of RCS, in the form CCS_aaaaa.aaabb.bbcd.defffff.fffgg.gghi.ijklmnnnopqqqqrs where: aaaaa.aaa = Conv A frequency in MHz bb.bb = Conv A attenuation in dB c = Conv A mute state, 0 = 7–10nmated, 1 = muted d.d = Conv A slope adjust e = Conv A online/offline (redundancy) fffff.fff = Conv B frequency in MHz gg.gg = Conv B attenuation in dB h = Conv B mute state, 0 = unmuted, 1 = muted i.i = Conv B slope adjust j = Conv B online/offline (redundancy) k = Converter redundancy l = auto fault recovery, 1=auto, 0=manual m = external ref present, 0=no ext ref, 1=present nnn = internal ref. Oscillator adjust (000-255) o = remote mode, 1=remote, 0=local p = remote interface, 0=EIA-232, 1=EIA-485 qqqq = remote address (0-9999) r = remote baud rate (0=38400, 1=19200, 2=9600, 3=4800, 4=2400, 5=1200) s = remote data format (0 = 8N1, 1=7E2, 2=7O2) 7–10 Response to Command (Target to controller) N/A Query (Instruction Code and qualifier) Response to query (Target to controller) CAS_ CAS_x….x (see Description of Arguments for details) N/A CCS_ CCS_ x….x (see Description of Arguments for details) LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Configure Mute Mode Concise Maintenance Status Command (Instruction Code and Qualifier) CMM_ N/A Arguments for Command or Response to Query 5 bytes, alpha 85 bytes numeric Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Response to Command (Target to controller) Command or Query. Same as command Turns the mute mode ON or OFF. When mute mode is OFF (default), the unit will mute upon changing RF frequency. When mute mode is ON, the unit will remain whatever its mute state upon changing RF frequency: In the form CMM_y_xxx'cr''lf'] where: y = ‘A’ (Converter A) or ‘B’ (Converter B) xxx = ON (mute) or OFF (unmute) Example: CMM_A_OFF (Unmutes Converter A) Query only. N/A Used to Query the Maintenance Status of the unit in concise format, in the form CMS_aaa.abbb.bccc.cddd.deee.efff.fggg.ghhh.hiii.ijjj.jkkk.klll.lm mm.mnnn.nooo.oppp.pqqq.q’cr’’lf’ where: aaa.a = 12 VDC supply #1 in volts bbb.b = 8 VDC supply #1 in volts ccc.c = 5 VDC supply #1 in volts ddd.d = 12 VDC supply #2 in volts eee.e = 8 VDC supply #2 in volts fff.f= 5 VDC supply #2 in volts ggg.g = Ref Osc tuning voltage in volts hhh.h = Converter A IFLO tuning voltage in volts iii.i= Converter A RFLO tuning voltage in volts jjj.j = Converter A Input Power in dBm (Reserved for future use) kkk.k = Converter A Output Power in dBm (Reserved for future use) lll.l= Converter A temperature in degrees C mmm.m = Converter B IFLO tuning voltage in volts nnn.n= Converter B RFLO tuning voltage in volts ooo.o = Converter B Input Power in dBm (Reserved for future use) ppp.p = Converter B Output Power in dBm (Reserved for future use) qqq.q = Converter B temperature in degrees C 7–11 Query (Instruction Code and qualifier) Response to query (Target to controller) CMM_y_ CMM_y_xxx (see Description of Arguments for details) CMS_ CMS_ x….x (see Description of Arguments for details) LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Concise Utility Status Set RTC (Real-TimeClock) Date Command (Instruction Code and Qualifier) N/A DAT_ Force Backup Unit FBU_ Operating Frequency FRE_ Fault Relay Logic FRL_ Arguments for Command or Response to Query Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) 43 bytes alphanumeric Query only. Used to Query the Maintenance status of the unit, in the form CUS_tt:tt:ttdd/dd/ddabcsssfffffffggggggghhhhhhh where: tt:tt:tt = time in hh:mm:ss dd/dd/dd = date in mm/dd/yy a = X (reserved for future use) b = X (reserved for future use) c = display brightness (0=100%, 1=75%, 2=50%, 3=25%) sss = screen saver time in minutes fffffff = Bulk firmware ggggggg = M&C firmware hhhhhhh = FPGA firmware 8 bytes, Command or Query. A command/query in the form DAT_mm/dd/yy where: numeric dd = day of the month, between 01 and 31 mm = month of the year, between 01 and 12 yy = year, between 00 and 96 (2000 to 2096) Example: DAT_04/25/03 (would be April 25, 2003) 0 bytes Command only. Forces switchover to backup unit in Manual redundancy mode only in the form FBU_ 11 bytes, Command or Query. In the form FRE_x_yyyyy.yyy where: alphanumeric x = ‘A’ (Converter A) or ‘B’ (Converter B) yyyyy.yyy =Valid Operating frequency, in MHz and 1-kHz step. Note: The user has the option to set it at Ku-Band frequency for example, 14500.000 MHz, if the ‘frequency display select’ option is turned ON. Example: FRE_A_00951.000 (Converter A is set to 951 MHz) 1 byte, numeric Command or Query. In the form FRL_x where: x = 0 (Normal Logic) or 1 (Inverted Logic) 7–12 Response to Command (Target to controller) N/A Query (Instruction Code and qualifier) CUS_ Response to query (Target to controller) CUS_ x….x (see Description of Arguments for details) Same as command DAT_ DAT_mm/dd/yy (see Description of Arguments for details) Same as command N/A N/A Same as command FRE_x_ FRE_x_yyyyy.yyy (see Description of Arguments for details) Same as command FRL_ FRL_ (see Description of Arguments for details) LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Retrieve Firmware Number List all alarms Mute State Command (Instruction Code and Qualifier) N/A N/A MUT_ Arguments for Command or Response to Query variable 5 bytes, alpha Online Unit Status N/A 1 byte alphanumeric Retrieve Alarm Status N/A 122 bytes alphanumeric Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Query only. Gets the Firmware Numbers of the unit. Example: FRW_ BULK=FW/9965X M&C =FW/9966X FPGA=FW/9967X (Where ‘X’ denotes the firmware revision letter) Query only. This command retrieves a list of the stored alarms. List All Alarms: LAA_’cr’ Confirmation: LAA_’cr’ xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’ xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’ xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’ “ “ “ “ “ “ “ “ xx yyyyyyyyyyy hh:mm:ss mm/dd/yy’cr’’lf’] Where: xx = stored fault number. Yyyyyyyyyyy = fault description. Hh:mm:ss = fault time. Mm/dd/yy = fault date. Command or Query. Mutes/Unmutes the converter in the form MUT_x_yyy where: x = ‘A’ (Converter A) or ‘B’ (Converter B) yyy = ON (mute) or OFF (unmute) Example: MUT_A_OFF (Unmutes Converter A) Query only. Indicates which slot is online in the form ONL_x where: x = A or B (depending on which Converter is online). Query only. Used to Query the Alarm status of the unit, where: xx = OK (no fault) or FT (fault): 7–13 Response to Command (Target to controller) N/A Query (Instruction Code and qualifier) Response to query (Target to controller) FRW_ FRW_ (see Description of Arguments for details) N/A LAA_ LLA_ xx y..y h..s m..y (see Description of Arguments for details) Same as command MUT_x_ MUT_x_yyy (see Description of Arguments for details) N/A ONL_ N/A RAS_ ONL_ (see Description of Arguments for details) RAS_ x….x LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Retrieve Configuration Status Command (Instruction Code and Qualifier) N/A Arguments for Command or Response to Query 186 bytes alphanumeric Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) 12VDC1_xx’cr’ 12 VDC #1 Fault. 08VDC1_xx’cr’ 8 VDC #1 Fault. 05VDC1_xx’cr’ 5 VDC #1 Fault. 12VDC2_xx’cr’ 12 VDC #2 Fault. 08VDC2_xx’cr’ 8 VDC #2 Fault. 05VDC2_xx’cr’ 5 VDC #2 Fault. REFLD_xx’cr’ Ref Osc. Lock Detect Fault.* IFLOA_xx’cr’ Conv A IFLO Lock Detect Fault. RFLOA_xx’cr’ Conv A RFLO Lock Detect Fault. TEMPA_xx’cr’ Conv A Over Temperature Fault. IFLOB_xx’cr’ Conv B IFLO Lock Detect Fault. RFLOB_xx’cr’ Conv B RFLO Lock Detect Fault. TEMPB_xx’cr’’lf’ Conv B Over Temperature Fault. *Note: REFLD is only returned if an external reference is present. Query only. Used to Query the Configuration Status of the unit in the form RCS_ : FRE_A_01694.765 Conv A frequency ATT_A_03.00 Conv A attenuation TX_A_ON Conv A mute state SLP_A_0.0 Conv A slope adj. ONL_A_ON Conv A on/offline FRE_B_11444.765 Conv B frequency ATT_B_15.00 Conv B attenuation RX_B_ON Conv B mute state SLP_B_0.0 Conv B slope adj. ONL_B_ON Conv B on/offline RED_OFF Conv redundancy AFR_ON auto flt recovery EXT_NO external ref. REF_087 ref osc adjust REM_YES remote mode COMM_RS-232 remote interface ADD_0001 remote address BR_9600 remote baud rate FMT_8-N-1 remote data format 7–14 Response to Command (Target to controller) Query (Instruction Code and qualifier) Response to query (Target to controller) (see Description of Arguments for details) N/A RCS_ RCS_ x….x (see Description of Arguments for details) LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Redundancy Mode Command (Instruction Code and Qualifier) RED_ Remote Mode REM_ 1 byte, value 0 or 1 Retrieve Module Equipment Type N/A 12 bytes, alphanumeric Parameter Type Retrieve Equipment Type Retrieve Maintenance Status N/A N/A Arguments for Command or Response to Query 3 bytes alphanumeric 22 bytes, alphanumeric 203 bytes, alphanumeric Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Command and Query. Used to set the chassis in redundancy mode or to query status of redundancy in the form RED_xxx where: xxx = ON (if redundancy is enabled) or OFF(if redundancy is disabled) Command or Query Sets to remote mode or local mode in the form REM_x where: x = 0 (local mode) or 1 (remote mode) Query only. The unit returns a string indicating the frequency of the selected module and the module type (Up-Link or Down-Link) in the form RET_x_ where: x = ‘A’ or ‘B’ Example: RET_A_140_DL or RET_B_070_UL Query only. The unit returns a string indicated the Model Number and the value of internal software revision installed Example: RET_LBC-4000 VER:1.2.1 Query only. Used to Query the maintenance status of the unit in the form RMS_’cr’ : 12VT1=xxx.x’cr’ 12 VDC Supply #1 in volts. 08VT1=xxx.x’cr’ 8 VDC Supply #1 in volts. 05VT1=xxx.x’cr’ 5 VDC Supply #1 in volts. 12VT2=xxx.x’cr’ 12 VDC Supply #2 in volts. 08VT2=xxx.x’cr’ 8 VDC Supply #2 in volts. 05VT2=xxx.x’cr’ 5 VDC Supply #2 in volts. VTREF=xxx.x’cr’ Ref Osc tuning voltage in volts. IFLOA=xxx.x’cr’ Conv A IFLO tuning voltage, V. RFLOA=xxx.x’cr’ Conv A RFLO tuning voltage, V. PIN_A=xxx.x’cr’. Conv A Input power in dBm. POUTA=xxx.x’cr’ Conv A Output power in dBm. TEMPA=xxx.x’cr’ Conv A temperature in deg C. IFLOB=xxx.x’cr’ Conv B IFLO turning voltage, V. RFLOB=xxx.x’cr’ Conv B RFLO tuning voltage, V. PIN_B=xxx.x’cr’ Conv B Input power in dBm. POUTB=xxx.x’cr’ Conv B Output power in dBm. TEMPB=xxx.x’cr’’ Conv B temperature in deg C 7–15 Response to Command (Target to controller) Query (Instruction Code and qualifier) Response to query (Target to controller) Same as command RED_ RED_ (see Description of Arguments for details) Same as command REM_ N/A RET_x_ REM_x (see Description of Arguments for details) RET_x….x (see Description of Arguments for details) N/A RET_ RET_x….x (see Description of Arguments for details) N/A RMS_ RMS_ x….x (see Description of Arguments for details) LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Retrieve Utility Status Command (Instruction Code and Qualifier) N/A Arguments for Command or Response to Query 98 bytes alphanumeric Set Auto/Manual Redundancy Mode SAM_ 1 byte alphanumeric Summary Alarm Status N/A 2 bytes, alpha Remote Baud Rate Remote Address SBR_ SPA_ 4 bytes 4 bytes, numeric Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Query only. Used to Query the utility features of the unit in the form RUS_ where: TIME=hh:mm:ss DATE=mm/dd/yy FSDA=xxxx (Reserved for future use) FSDB=xxxx (Reserved for future use) BVFD=yyy SCRT=zzz BULK=FW9965X (where X is the revision letter) M&C =FW9966X (where X is the revision letter) FPGA=FW9967X (where X is the revision letter) Command and Query. Used to set or get status of Redundancy to either Manual or Automatic mode in the form SAM_x where: x = a (if chassis is in Automatic Redundancy mode) or m (if chassis is in Manual Redundancy mode) Query only. Used to Query the status of the Summary Fault Relay in the form SAS_xx where: xx = OK or FT Example: SAS_OK Command or Query. Used to set or query the serial baud rate in the form SBR_xxxx where: xxxx = remote baud rate as follows: 1200 = 1200 baud 2400 = 2400 baud 4800 = 4800 baud 9600 = 9600 baud 19K2 = 19200 baud 38K4 = 38400 baud Command or Query. Used to set or query the physical address in the form SPA_xxxx where: xxxx = Set Physical Address-between 0001 to 9999. Resolution=0001 Example: SPA_0412 7–16 Response to Command (Target to controller) N/A Query (Instruction Code and qualifier) RUS_ Response to query (Target to controller) RUS_ x….x (see Description of Arguments for details) Same as command SAM_ SAM_ (see Description of Arguments for details) N/A SAS_ SAS_x (see Description of Arguments for details) Same as command SBR_ SBR_xxxx (see Description of Arguments for details) Same as command SPA_ SPA_xxxx (see Description of Arguments for details) LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Spectrum Inversion Command (Instruction Code and Qualifier) SPI_ Arguments for Command or Response to Query 5 bytes Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Command or Query. Used to set or query the Converter spectrum inversion setting, in the form SPI_x_yyy where: x = ‘A’ (Converter A) or ‘B’ (Converter B) yyy = NRM (normal spectrum) or INV (inverted spectrum). Response to Command (Target to controller) Same as command Query (Instruction Code and qualifier) Response to query (Target to controller) SPI_x_ SPI_x_ (see Description of Arguments for details) Example: SPI_A_INV (Converter A set to inverted spectrum) Reference Oscillator Adjust Slope Adjust Serial Number Set RTC Time SRO_ SSA_ N/A TIM_ 3 bytes, numeric 5 bytes, alphanumeric 9 bytes, numeric 000000000 to 999999999 8 bytes, numeric Note: This command is only valid for down converters. Command or Query. Used to set or query the Reference Oscillator Adjustment in the form SRO_xxx where: x = Ref Osc Adjust, between 000 and 255. Resolution 001. Example: SRO=087 Note: SRO cannot be adjusted when the unit is locked to an external reference source. Command or Query. Used to set or query the Converter slope adjustment level, in the form SSA_x_y.y where: x = ‘A’ (Converter A) or ‘B’ (Converter B) y.y = Converter slope adjust level, valid from 0.0 to 1.0 with 0.1 resolution. Example: SSA_B_0.3 (Converter B slope adjust is set to 0.3) Same as command SRO_xxx (see Description of Arguments for details) Same as command Query only. N/A Returns the serial number of the selected unit in the form SSN_x_yyyyyyyyy where: x = ‘U’ (unit), ‘A’ (Conv A), or ‘B’ (Conv B) yyyyyyyyy = the 9 digit serial number of the unit or the converter. Example: SSN_B_ (queries for serial number of Converter B) Command or Query. Same as command Sets or queries the real-time clock in the form TIM_hh:mm:ss where: hh=hours (midnight/military format) between 00 and 23 mm = minutes, between 00 and 59 ss = seconds, between 00 and 59 Example: TIM_23:12:59 would be 23 hours, 12 minutes and 59 seconds from midnight. 7–17 SRO_ SSA_x_ SSA_x_ (see Description of Arguments for details) SSN_x_ SSN_x_yyyyyyyyy (see Description of Arguments for details) TIM_ TIM_hh:mm:ss (see Description of Arguments for details) LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Vacuum Fluorescent Display (VFD) Brightness Adjust Command (Instruction Code and Qualifier) VFD_ Arguments for Command or Response to Query 1 byte, value 0 to 3 Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Response to Command (Target to controller) Query (Instruction Code and qualifier) Response to query (Target to controller) Command or Query. Sets the front panel display brightness in the form VFD_x where: x = 0 (100%), 1 (75%), 2 (50%), or 3 (25%) Command or Query Used to set the IP Address and network prefix for the 10/100base T Ethernet management port, in the format: xxx.xxx.xxx.xxx.yy, where: xxx.xxx.xxx.xxx is the IP address, and yy is the network prefix (8-30) Example: 192.168.001.004.24 Used to set the gateway IP address for the 10/100base T Ethernet management port, in the format: xxx.xxx.xxx.xxx, where: xxx.xxx.xxx.xxx is the IP address Example: IPG = 192.168.001.005 Same as command VFD_ VFD_x (see Description of Arguments for details) Same as command IPA_ Ipa_xxx.xxx.xxx.xxx.y y Same as command IPG_ Ipg_xxx.xxx.xxx.xxx IP Address IPA_ 18 bytes Gateway Address IPG_ 15 bytes Unit MAC Address N/A 12 bytes Query MAC address of the unit, reported in hexadecimal. aa bb cc dd ee ff Example: MAC_0006B00001C2 N/A MAC_ mac_aabbccddeeff Firmware Image Selection IMG_ 1 byte Command or query: Selects which bulk image to boot from where x = 1=bulk image 1 2=bulk image 2 Same as command IMG_ Img_x Local/ Remote Status LRS_ 1 byte 0 to 3 Command or Query LRS LRS? LRS* LRS# LRS_ LRS=x Used to set the user’s Local/Remote status in the form x, where: 0=Local 1=Serial Remote (RS-232/RS-485) 2=Ethernet 3=Ethernet Remote Example: LRS=1 (selects serial remote) 7–18 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Parameter Type Firmware Command (Instruction Code and Qualifier) N/A Arguments for Command or Response to Query Revision 2 MN-LBC4000A Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Response to Command (Target to controller) Query Query (Instruction Code and qualifier) Response to query (Target to controller) FRM_ FRM_ PNM_x_ PNM=x.....x Returns firmware information for the Boot Rom, Image1 and Image2. For example: Boot: FW-0020506;1.1.1;06/07/11 Bulk1: FW-0020503;1.2.1;06/15/11 FW-0020504;1.1.1;06/15/11 FW-0020505;1.1.1;06/07/11 Part Number N/A Various 1-96 bytes Bulk2: FW-0020503;1.2.1;06/17/11 FW-0020504;1.1.1;06/15/11 FW-0020505;1.1.1;06/07/11 Query only. N/A Returns the Comtech EF Data part number for the Unit, Slot A or Slot B. This part number is the DOTCODE at the time it was manufactured. The DOTCODE may be up to 96 printable ASCII characters long. <1/PNM_U_ returns the Units Part Number <1/PNM_A_ returns Slot A Part Number <1/PNM_B_ returns Slot B Part Number 7–19 LBC-4000 L-Band Up/Down Converter System with Ethernet Serial-based Remote Product Management Revision 2 MN-LBC4000A Notes: 7–20 Appendix A. UP/DOWNCONVERTER IDU MODULE REMOVAL/RE-INSTALLATION A.1 Introduction This appendix illustrates the procedure required to remove and re‐install an IDU for the LBC‐4000 Up/Down Converter System with Ethernet into any LBC‐4000 chassis (Figure A‐1, showing a serial‐only, non‐Ethernet base unit with the top cover removed for clarity). This procedure is typical for removing or installing an IDU into the LBC‐4000’s applicable Conv A or Conv B bay. Although Figure A‐1 shows the chassis for the LBC‐4000 L‐Band Up/Down Converter System without Ethernet, the procedures in this appendix are identical for the Ethernet‐based LBC‐4000. Figure A-1. LBC-4000 Chassis – IDU Module Bays A–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix A A.2 IDU Module Removal Procedure Step Task Revision 2 MN-LBC4500A 1 Loosen the three thumb screws and drop the front panel to access the IDU modules. 2 Using a Phillip’s®‐head screwdriver, remove the machine screws holding the IDU module in place. A–2 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix A Step Revision 2 MN-LBC4500A Task 3 4 Remove the Reference Cable by first unlocking (turning counterclockwise), then removing the connector from its socket. Remove the Ribbon (Data) Cable by first unlocking, and then removing the connector from its socket. (a) Unlock Connector A–3 (b) Remove Connector LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix A Step Revision 2 MN-LBC4500A Task 5 Using the front handle, remove the IDU module from the chassis by sliding the unit straight out until it is free and clear of its internal housing. A–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix A A.3 IDU Module Installation Procedure Step Task Revision 2 MN-LBC4500A 1 2 Taking care to ensure the IDU module is properly engaged within its internal housing, use the front handle on the IDU module to slide the IDU module into a position that allows installation of the Reference and Ribbon Cables. (a) Install connector Connect the Ribbon (Data) Cable by first inserting and then locking the connector into its socket. A–5 (b) Lock connector LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix A Revision 2 MN-LBC4500A 3 Connect the Reference Cable by first installing the connector onto the socket, and then locking the connector into place (turning clockwise). 4 Using the front handle on the IDU module, slide the IDU module the remainder of the way into its internal housing. A–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix A Revision 2 MN-LBC4500A 5 Swing the front panel back into operating position and finger‐tighten the three thumbscrews. The IDU module installation is complete and the LBC‐4000 L‐Band Up/Down Converter System with Ethernet is ready for connection to other equipment. See Chapter 3. REAR PANEL CONNECTIONS for further information. A–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix A Revision 2 MN-LBC4500A Notes: A–8 Appendix B. LBC-4000 REDUNDANCY OPERATION B.1 Introduction The LBC‐4000 L‐Band Up/Down Converter System with Ethernet can optionally be configured for redundant system operation. This appendix provides detailed information for cabling and otherwise configuring the LBC‐4000 for 1:1 redundancy. B.2 Redundancy Operations Overview • Figure B‐1 provides a functional schematic for LBC‐4000 redundant operation. • Figure B‐2 illustrates the cabling requirements for redundant operation. Note the following: o o BNC connections, where applicable, use 50Ω BNC male‐to‐male cables. It is recommended that all Type ‘N’ to Type ‘SMA’ cable connections are best accomplished using a Type ‘N’ male to Type ‘SMA’ female adapter, then using Type ‘SMA’ female‐to‐female cables. • Sect. B.3 addresses the control and configuration of an LBC‐4000 Redundancy System via the LBC‐4000 front panel. • Sect. B.4 addresses the control and configuration of an LBC‐4000 Redundancy System via the LBC‐4000 Web Server Interface. • Sect. B.5 addresses the control and configuration of an LBC‐4000 Redundancy System via serial remote control. B–1 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Figure B-1. LBC-4000 Redundancy – Functional Schematic Figure B-2. LBC-4000 Redundancy Cabling Schematic B–2 Revision 2 MN-LBC4000A LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Revision 2 MN-LBC4000A B.3 Redundancy Operations via the LBC-4000 Front Panel You can configure, monitor, and control redundancy operation via the LBC‐4000 front panel, using the keypad and display. Nested menus are used, which display all available options, and prompt you to carry out a required action. Figure B‐3 identifies the key features of the LBC‐4000 front panel; see Chapter 5. FRONT PANEL OPERATION for in‐depth explanations of the function and operation of this operational interface. Feature See Chapter Section... Description Function 1 Rack Handles The handles allow quick installation into and removal of the unit from an equipment rack. 2 Prime Power Switch The Prime Power Switch is located inside the front panel rear panel. Loosen the thumbscrews, slide the front panel out from the chassis, and then swing down. 3.3.2.3 5.1.1 3 Converter LED Indicator Group The two groups of LEDs indicate, in a summary fashion, the status of each converter. 5.1.2 4 Keypad The keypad comprises six keyswitches behind a flat membrane. Enter data via the keypad. 5.1.3 5 Vacuum Fluorescent Display (VFD) The VFD is an active display showing two lines of 24 characters each. It produces a blue light with adjustable brightness. Nested menus, data, prompts, and messages are displayed on the VFD. 5.1.4 Figure B-3. LBC-4000 Front Panel B–3 2.2 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Revision 2 MN-LBC4000A B.3.1 Main Menu Chapter 5. FRONT PANEL OPERATION The Main Menu for the LBC‐4000 appears as follows: CONFIG MONITOR UTILITY FAULTS For quick reference, a description of each of the menu branches follows, and the section in this appendix (as shown in bold) that addresses use relevant to Redundancy operation. Otherwise, see Chapter 5. FRONT PANEL OPERATION for complete information on the functionality of these features: Menu Branch Ch 5 / App B Sect Functional Description Config 5.2.1 / B.3.2 Monitor 5.2.2 Use to monitor the alarm status of the unit, to view the log of stored events, and to display the Receive Parameters screen. Faults 5.2.3 Use to view information on the unit, without having to go into configuration screens. Utility 5.2.4 Use to perform miscellaneous functions, such as setting the Real-time clock, adjusting the display brightness, etc. (Configuration) Use to fully configure the LBC-4000. B–4 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Revision 2 MN-LBC4000A B.3.2 CONFIG (Configuration) Menu CONV-A REDUND CONV-B REMOTE REFADJ SPECT-INV Use the [←][→] arrow keys to select from the submenu choices shown, and then press [ENT]. Each submenu available from the Configuration menu branch is typical for Converter A or Converter B. For quick reference, a description of each of the submenu branches follows, and the section in this appendix (as shown in bold) that addresses use relevant to Redundancy operation. Otherwise, see Chapter 5. FRONT PANEL OPERATION for complete information on the functionality of these features: Submenu Ch. 5 / App. B Sect Description 5.2.1.1 B.3.4 (Converter Unit A or B) Displays the current configuration of the selected converter, including the frequency, attenuation, and slope. REMOTE 5.2.1.2 (Remote Control) Defines whether the unit is being controlled locally or remotely, and identifies the unit address, interface type, and rate and format of the baud parameters. REDUND 5.2.1.3 B.3.3 (Redundancy) Identifies the redundancy state and mode REFADJ 5.2.1.4 (Reference Oscillator Adjustment) Adjusts the reference oscillator. SPECT-INV 5.2.1.5 (Spectrum Inversion) CONV-A CONV-B B–5 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Revision 2 MN-LBC4000A B.3.3 CONFIG: REDUND (Redundancy) Redundancy Mode State FrcBkup Use the [←][→] arrow keys to select Mode, State, or FrcBkup, and then press [ENT]. CONFIG: Redundancy Æ Mode Redundancy Control Mode = Manual Use the [↑][↓] arrow keys to select Manual or Auto, and then press [ENT]. Note that, if you attempt to access this menu and the Redundancy State is selected as Disabled, the following message displays: Not in Redundancy Mode! CONFIG: Redundancy Æ State Redundancy Mode: Control State = Enable Use the [↑][↓] arrow keys to select Disable or Enable, and then press [ENT]. CONFIG: Redundancy Æ FrcBkup Config Manual Redundancy Force Backup NO To force the redundant unit into standby mode, use the [↑][↓] arrow keys to select YES or NO. Press [ENT] when done. Note that, if you attempt to access this menu and the Redundancy State is selected as Disabled, the following message displays: Not Available in Current Mode B–6 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Revision 2 MN-LBC4000A B.3.4 Gain Offset for Redundant Operations Once redundancy has been enabled, the Ofst (Gain Offset) command, available from the Configure: Conv‐A Æ Atten/Slope submenu, allows gain offset compensation in order for you to match gain between the two converters. Gain Offset is set at installation only. In operation, the normal attenuation setting should be used. The procedure to set the Gain Offset parameters for redundant operation is as follows: Step Task 1 Monitor output signal level on power meter / spectrum analyzer. 2 Enable Redundancy on converter (CONFIG Æ REDUND Æ STATE=Enable). 3 Put converter into “Manual” Redundancy Mode (CONFIG Æ REDUND Æ MODE=Manual). 4 Force Converter B online (CONFIGÆREDUNDÆFrcBkup=YES) and measure output . Force Converter A online (SELECT: CONFIGÆREDUNDÆFrcBkup=YES) and then, using the SELECT: CONFIG Æ Conv-A menu: 5 CONFIG CnvA: Ofst=+0.0dB Atten=00.00dB Slope=0.0 Adjust Ofst (Gain Offset) by first using the [←][→] arrow keys to select the Gain Offset digit to edit, and then the [↑][↓] arrow keys to change that value. Once the Gain Offset output value matches Converter B, press [ENT]. 6 Repeat Steps 4 and 5 until output levels track. 7 Return unit to desired redundancy state. B–7 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Revision 2 MN-LBC4000A B.4 Redundancy Operations via the LBC-4000 Web Server Interface Chapter 6. ETHERNET‐BASED REMOTE PRODUCT MANAGEMENT Use the LBC‐4000 Web Server Interface ‘Config | Redundancy’ page to configure the LBC‐4000’s Redundancy Switch Mode. Figure B-4. Config | Redundancy page Redundancy State Use the drop‐down menu to Enable or Disable LBC‐4000 Redundancy, and then click [Change] to set LBC‐4000 Redundancy operation to this select status. Redundancy Mode Use the drop‐down menu to select Redundancy Mode operation as Manual or Auto, and then click [Change] to update LBC‐4000 Redundancy operation to this select operating mode. Force Backup Use the drop‐down menu to select Yes, and then click [Change] to force the redundant unit into standby mode. The last section on this page displays the read‐only Online or Offline status for each converter. To update the page with its latest operating parameters, click [Refresh]. B–8 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Revision 2 MN-LBC4000A B.5 Redundancy Operations via Serial Remote Control See Chapter 7. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for detailed information about using Serial Remote Control commands and queries for remote Redundancy configuration, operation, and monitoring. The following remote commands and queries are available for LBC‐4000 Redundancy operation: Parameter Type Command / Query Force Backup Unit FBU Redundancy Mode RED Set Auto/Manual Redundancy Mode SAM Description of Arguments (Note that all arguments are ASCII numeric codes between 48 and 57) Command only. Forces switchover to backup unit in Manual redundancy mode only in the form FBU_ Command or Query. Used to set the chassis in redundancy mode or to query status of redundancy in the form RED_xxx where: xxx = ON (if redundancy is enabled) or OFF(if redundancy is disabled) Command or Query. Used to set or get status of Redundancy to either Manual or Automatic mode in the form SAM_x where: x = a (if chassis is in Automatic Redundancy mode) or m (if chassis is in Manual Redundancy mode) B–9 LBC-4000 L-Band Up/Down Converter System with Ethernet Appendix B Notes: B–10 Revision 2 MN-LBC4000A METRIC CONVERSIONS Units of Length Unit Millimeter Centimeter Inch Foot Yard Meter Kilometer Mile 1 millimeter 1 0.1 0.0394 0.0033 0.0011 0.001 1 x 10-6 6.214 x 10-7 1 centimeter 10 1 0.3937 0.0328 0.0109 0.01 1 x 10-5 6.214 x 10-6 1 inch 25.4 2.54 1 0.0833 0.0278 0.0254 2.54 x 10-5 1.578 x 10-5 1 foot 304.8 30.48 12 1 0.3333 0.3048 3.048 x 10-4 1.894 x 10-4 1 yard 914.4 91.44 36 3 1 0.9144 9.144 x 10-4 5.682 x 10-4 1 meter 1000 100 39.37 3.2808 1.0936 1 0.001 6.214 x 10-4 1 kilometer 1 x 106 1 x 105 3.938 x 104 3.281 1093 1000 1 0.6214 1 mile 1.609 x 106 1.609 x 105 6.336 x 104 5280 1760 1609 1.609 1 Temperature Conversions Temperature ° Fahrenheit ° Centigrade Formulas Water freezes 32 0 ° C = (F - 32) * 0.555 Water boils 212 100 ° F = (C * 1.8) + 32 Absolute zero -459.69 -273.16 Units of Weight Unit Gram Ounce Avoirdupois Ounce Troy Pound Avoirdupois Pound Troy Kilogram 1 gram — 0.03527 0.03215 0.002205 0.002679 0.001 1 oz. avoir. 28.35 — 0.9115 0.0625 0.07595 0.02835 1 oz. troy 31.10 1.097 — 0.06857 0.08333 0.03110 1 lb. avoir. 453.6 16.0 14.58 — 1.215 0.4536 1 lb. Troy 373.2 13.17 12.0 0.8229 — 0.3732 1 kilogram 1.0 x 103 35.27 32.15 2.205 2.679 — 2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX ">
Advertisement
Key features
- L-band Up/Down Converter System
- Ethernet-based remote product management
- SNMP, Telnet, HTTP interfaces
- 1:1 redundancy capability
- Front panel operation
- Firmware update
- Multiple RF and IF connector options
- Coaxial and D-subminiature cable connections
- Vacuum fluorescent display (VFD)
- LED indicators
Frequently asked questions
The LBC-4000 is an L-band Up/Down Converter System with Ethernet that allows for remote product management. It can be used for a variety of applications such as satellite communication, terrestrial microwave links, and other RF systems.
The LBC-4000 supports Ethernet, Telnet, and HTTP interfaces for remote management. These interfaces allow for configuration, monitoring, and control of the device remotely.
The LBC-4000 firmware can be updated via the Internet using an FTP upload procedure.
The LBC-4000 features multiple RF and IF connector options, including BNC, TNC, N, F, and SMA.
The LBC-4000 can operate in ambient temperatures between 0°C (32°F) and 50°C (122°F), with a maximum humidity of 95% relative humidity. It should not be operated in unpressurized altitudes greater than 2000 meters (6561.7 feet).