Contactless Sensor Flush Kit
General Care and Safety
CREAM
CLEANER
BLEACH
CLEANER
for Close Coupled W/Cs
Fitting Instructions
Please do not use corrosive cleaners or solvents or any chemical agent
within the water tank. Cleaners or solvents containing chlorine or
calcium hypochlorite may seriously damage the product.
Please read completely first before commencing and retain for future reference
TR9031/TR9032
The surface of the sensor should be kept clean and clear of dirt or water
droplets to ensure optimum performance.
The working water temperature range for this product is 2°-45°.
QUICK INSTALLATION GUIDE
For a quick installation
guide, follow the
instructional video by
scanning the QR code
to the right on your
smart device:
Parts Included
FU
LL
HA
LF
1x Control Box
22
Brought to you by the Roper Rhodes Group
Brassmill Lane Trading Estate
Bath
BA1 3JF
t: 01225 303900
TR9031/TR9032
EMC
1x Battery Box
Cradle
1x Battery Box
1x Stainless Steel
Hanger
1x Clamp Collar
1x Button with
Securing Nut
1x IR Sensor
1s
1x Instructional
Sticker
BS EN 61000-6-1:2019
RoHS
BS EN IEC 63000:2018
V1.2.TP.09.2021
8
1x Clamp and
Pneumatic Hook
1x Flush Button
Leg
1
Usage Instructions
Before you start
30cm
1s
It is recommended to isolate the water supply
and flush the water from the cistern before
commencing installation.
Ensure that there is a 30cm clear area above
the cistern. Any obstructions such as shelves or
hanging objects could trigger the sensor if
positioned within this area.
Ensure that the cistern fittings are suitably arranged to allow for installation of the sensor flush kit by making the following
provisions:
Make sure that the overflow tube is positioned
on the opposite side of the cistern to the inlet
valve
Rotate the flush valve so that the REDUCED
flush paddle is on the same side as the overflow
tube.
Once the installation is complete, to activate a reduced flush, wave your hand over the sensor. To activate a full flush
hold your hand over the sensor for 1 second. When activated, a red light will show on the sensor.
Battery Replacement
When the battery level is
too low, the red indicator
light on the sensor will
blink for 10 seconds
when activated.
x10
The batteries must be
replaced using the
method shown below.
In the meantime, the full
flush function can be
activated using the
manual flush button.
BLUE PADDLE
WHITE PADDLE
To access the battery box, first disconnect the quick connector and remove the battery box from the cistern. Next, remove
the lid of the battery box making sure to squeeze the top washer to release the seal. You can now swap in new 4x1.5V AA
batteries and reconnect the battery box back up to the rest of the flush unit.
2
7
5 Fitting the Flush Button
Fitting Instructions
A
1 Loading the batteries
!
7
8
9
WARNINGS
6
Non-alkaline batteries will
provide a much shorter battery
life.
Do not mix batteries of different
brands or mix old and new
batteries.
i
1
2
3
4
5
1
6
2
7
3
8
4
9
5
iii
ii
Once connected to the power,
the flush system will act once to
show it is working.
With the cistern lid on, measure the distance from the top face on the cistern to the flush valve paddles through the
cistern hole. Mark this distance on the flush button leg, using the underside of button’s rim as your datum point. Cut the
leg down to length at the marked point.
B
C
D
Remove the battery
holder from the battery
box
Load 4x1.5V AA alkaline batteries
(supplied seperately) into the
battery holder
To form a seal in the
battery box, squeeze the
top washer until you no
longer hear any air leaving
the box.
If you are struggling to remove
the battery box lid, squeeze the
top washer to release the seal.
2 Choosing flush valve orientation
The pneumatic hook and overflow clamp will be attached to
the overflow tube of the flush valve so the flush valve must
be oriented to have the reduced flush on the OPPOSITE
side of the cistern to the inlet valve.
Secure the button in position by tightening the fixing nut and place the rubber bung onto the new cut end of the leg.
Ensure that the leg does not press the flush paddle down whilst in its rest position. Failure to do this may cause water to
constantly trickle into the WC pan.
6 Connecting up the Sensor
Once the flush valve is secured in position within the cistern,
ensure to check which side the hook needs to be attached to the
clamp so that it will sit above the reduced flush paddle. If the
hook orientation needs changing from the default, detach the
hook from the clamp body by unscrewing the fixing screw and
sliding the clamp body upwards. Switch the connection side by
using the grooves on the opposite side of the clamp body and
reconnect the two parts as shown above.
Insert the IR sensor into the slot in the bottom of the button until the locking clips engage and the sensor sits flush with the
top surface of the button. To complete the installation process, connect up the battery pack’s quick connector and place
the cistern lid back onto the cistern.
6
3
3 Installing the Clamp and Pneumatic Hook
4.2 Connecting the Battery Box to the Control Box
Connect the battery box to the control box using one of the three options shown below, connecting fixings A, B or C of the
two parts together. The arrangement may need to be selected depending upon the room available within the cistern.
Using Type A Fixings
C
A
To detach the clear hose from
the hook, simply press in the
black connector and pull the
hose out, this may make
installation easier. To reattach
the hose simply slide it into the
connector and check it has
gripped in place.
If you are using a flush valve
with a slimline overflow tube,
you will need to slide the
overflow collar over the
telescopic overflow.
If you are using the overflow
collar make sure that the lip is
at the bottom when sliding on
to the overflow tube, as shown
above. If installed incorrectly
the clamp may work loose
from the overflow tube.
ii
i
B
B
A
Using Type B Fixings
Using Type C
Fixings
iii
On top of control
box
4.3 Connecting the Assembly to the Flush Valve
Using the male connecting hooks on the control box, the two components can now be connected to the flush valve
assembly. Alternatively, the battery box and control box can each be attached to the back of the cistern using the stainless
steel hanger. This can save room with the width or height of the overall product as the hanger allows for the boxes to be
positioned lower down within the cistern.
To install the clamp and hook,
slide the clamp over the
overflow tube.
hint
if using the collar for a slimline
overflow tube ensure the collar
is on the overflow tube before
attaching the clamp.
For optimum functionality,
ensure that the hook is resting
on top of the reduced flush
paddle.
Once set in position tighten the
screw to clamp the
components in place
important
the hook must not press down
the paddle when in its resting
state or the toilet may
constantly trickle.
important
If using a flush valve with a
telescopic overflow, check that
the overflow is locked in
position.
OPTION A
4 Installing the Control Box and Battery Box
4.1 Attach the Battery Box Cradle
Insert the battery box into the cradle. This gives three options for assembly
between the battery box and the control box as shown below.
A
B
C
OPTION B
If you are struggling to find the best fit for your cistern, visit our website to view the individual step-by-step
fitting guide for each of our cisterns.
4
5
Troubleshooting Guide
Contactless Cistern Sensor Flush Kit
Please retain for future reference
TR9031/TR9032
Problem
Potential cause
Suggested action
The full flush is
flushing too much or
too little water.
The flush level setting
needs changing.
Increase or decrease the flush settings level as detailed below:
1
To activate the flush settings mode, first
disconnect and reconnect the power via
the quick release connector.
2
x5
Within 5 minutes of the power being
reconnected, wave your hand 5 times
across the sensor within 5 seconds.
3
The red indicator light will blink a number
of times from 1 to 5. This number
denotes the current flush volume setting.
The default factory setting is 5.
x1-5
4
1
5
4
3
Each time you wave your hand over the
sensor the level will increase by 1, up to a
maximum of 5. After level 5, the level will
return to 1. After each change, the red
light will flash to denote the new level.
2
5
15s
The clamp doesn’t
tighten fully around
the overflow pipe
Once on the desired level wait 15
seconds and the sensor will exit the
adjustment mode and can be used as
normal.
You may need to add
the collar part to the
clamp.
Slide the collar onto the overflow tube, this should allow you to secure the
clamp around the wider overflow tube, such as the one found on TR9033.
Ensure to install the collar in the correct orientation (with the rim facing
downwards).
Problem
Potential cause
Suggested action
When I activate my
flush button it flashes
and does not flush
The batteries have run
empty. In the meantime
please use the manual
back up flush:
Change the batteries as detailed below:
2
1
WARNINGS
!
Non-alkaline batteries will
provide a much shorter battery
life.
Do not mix batteries of different
brands or mix old and new
batteries.
3
4
Once connected to the power,
the flush system will act once to
show it is working.
5
If you are struggling to remove
the battery box lid, squeeze the
top washer to release the seal.
To access the battery box, first disconnect the quick connector and remove
the battery box from the cistern. Next, remove the lid of the battery box
making sure to squeeze the top washer to release the seal. You can now
swap in new 4x1.5V AA batteries and reconnect the battery box back up to
the rest of the flush unit.
The overflow pipe on
my flush valve moves
when I try to connect
the clamp
The telescopic
overflow pipe may be
unlocked
1
2
3
2) The height difference between the
opening of the fill valve and the
opening of the overflow pipe must
be at least 20mm or 2x diameter of
the fill valve opening.
Flush valve and inlet valve
arrangement requirements for type
AUK1 air gap.
The height difference between the
opening of the overflow pipe and the
top surface of the WC pan must be
a minimum of 300mm.
Brought to you by the Roper Rhodes Group
Brassmill Lane Trading Estate
Bath
BA1 3JF
t: 01225 303900
V1.2.TP.11.2021
25-32mm
WATER LEVEL
1) The height difference between the
water level and the opening of the
overflow pipe must be 25-32mm.
(AUK1) min 300mm
Flush valve and inlet valve
arrangement requirements for type
AG air gap.
see req.
Fully unlock the overflow pipe by twisting the telescopic part anticlockwise.
Adjust the height of the overflow pipe as required (please see diagram below
for a guide of requirements). Once at the correct height, ensure one of the
grooves in the telescopic overflow is aligned with the locking pin of the fixed
section and twist clockwise to lock in position.
">