Commercial generator set Quiet Gasoline Series QG 7000

Commercial generator set Quiet Gasoline Series QG 7000
Commercial generator set
Quiet GasolineTM Series
QG 7000
Features and benefits
Weight, size and sound level
•
•
Integrated hydraulic pump option (pictured)
Weight: 290 lb (132 kg)
•
•
•
•
•
Integrated housing design
•
Quietest and lowest vibration generator set in Its
class
Enclosed muffler for ease of installation
Self-diagnostic capability to simplify troubleshooting
Size: Length 33.6 in (853 mm), width 22.2 in (563 mm),
height 16.7 in (425 mm)
Sound: 70 dB(A) at 10 ft (3 m), typical installation, full
load
Runs two ACs with power to spare
Digital regulation for voltage stability as loads
change
2-year limited warranty, 5-year drive warranty
Models and ratings
Model
Fuel
Hz
Watts
Voltage
Amps
PF
Phase
Circuit breaker
7 HGJAE-2132
7 HGJAE-2556#
7 HGJAE-1912
7 HGJAE-6758♦
7 HGJAE-2137
6.5 HGJAE-2145
6.5 HGJAE-3554
Gasoline
Gasoline
Gasoline
Gasoline
Gasoline
LP vapor
LP vapor
60
60
60
60
60
60
60
7000
7000
7000
7000
7000
6500
6500
120
120/240
120/240
120/240
120/240
120/240
120
58.3
29.2
29.2
29.2
16.8
27.1
54.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1
1
1
1
3
1
1
2 pole, 30 A
2 pole, 30 A
2 pole, 30 A
2 pole, 30 A
3 pole, 18 A
2 pole, 30 A
2 pole, 30 A
- All 60 Hz models operate at 2880 r/min.
- Ratings apply up to 3000 ft (914 m) altitude, 85° F (29.4° C).
- Derating: Power output will decrease 3.5% for each 1000 ft (305 m) above 3000 ft (914 m), temperature derate not required for ambient**
temperatures under 120° F (49.2° C).
- Ratings are at intermittent power output.
# Splined shaft.
** Ambient is defined as the air temperature measured at the cooling air inlet to the set.
♦ Evaporative spec: For trailer applications required to meet Tier III Evaporative emissions of the California Air Resources board.
Effective January 1, 2011, gasoline generator sets on trailers, diesel chassis or any other non-motorized mobile apparatus must have an
EVAP generator set, approved tank, EVAP canister, hoses and fittings all meeting the CARB Tier 3 and EPA phase 3 standards and
specifications. This law applies in all 50 states.
Cummins®, Onan®, the "C" logo, Performance you rely on.TM and Quiet GasolineTM are
servicemarks, trademarks and/or registered trademarks of Cummins Inc.
Specifications are subject to change without notice
©2012 Cummins Power Generation. All Rights Reserved.
A-1441h (3/12)
Standard features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Engine details
Mechanical governor adjustable from service side
Cummins Onan OHV engine
Pressurized Thru Flow cooling system
4-point mounting system with coil spring vibration
isolators
Universal mounting tray with structural capability to
support the generator set in commercial mobile
applications
Integral USDA Forest Service-approved spark-arrestor
muffler
Integral control box
Instant one-touch stop switch
Electronic ignition
Self diagnostic capability
Hour meter
Battery charging - 5 A
Remote disable/continuous stop
Start and run without AC output - engine run only
Enclosed muffler provides noise reduction and ease of
installation
Sound-attenuated housing
Waterproof remote connector
Heavy-duty solenoid shift starter
Fuel filter
Spin-on, full-flow oil filter
Low oil pressure protection
Over/under speed protection
Low power factor field overcurrent protection
Digital voltage regulation
Hydraulic pump standard on some models
10 ft generator set output lead
Typical fuel consumption
Model: Cummins Onan OHV EH65V gasoline engine
Design: 4-cycle, OHV, 90-degree V-twin
Cylinders: 2
Bore: 80 mm
Stroke: 65 mm
Displacement: 39.8 in3 (653 cm3)
Compression ratio: 8:1
Oil capacity: 2.0 qt (1.9 L) including filter
Power (max): At 2880 r/min: - Gasoline-fueled
models: 14.0 hp - LP-fueled models: 11.6 hp
Cooling: Centrifugal blower, generator set mounted for
high effectiveness, pressurized system, vertical flow
Cooling air volume: 60 Hz: 500 ft3/min (14.2 m3/min)
at 2880 r/min. Air flow includes engine, generator set and
control cooling air flow
Fuel system:
Replaceable dry element air cleaner
- Gasoline - sidedraft carburetor
Electronic fuel pump with positive fuel shutoff (3 psi),
maximum fuel lift 3 ft (0.9 m), Automatic choke with
vacuum pull-off
Combustion air volume: 60 Hz: 18.9 ft3/min (0.53
m3/min) at 2880 r/min
- LPG - sidedraft mixer with demand regulator
Combustion air volume: 60 Hz: 18.3 ft3/min (0.51
m3/min) at 2880 r/min
Starting system: Remote, 12 V, negative ground;
automotive type starter with steel pinion and ring gear,
automatic start disconnect, connector for remote start
cable, start-stop rocker switch mounted on set control
Ignition system: Electronic magneto type with
resistor plugs
Lubrication: Full pressure positive displacement lube
oil pump, spin-on, full-flow lube oil filter, low oil pressure
shutdown, dipstick
Cylinder crankcase: Alloy aluminum with iron
cylinder liners cast into the block, aluminum oil base
Cylinder head: Aluminum, OHV, removable
Gasoline, Gal/hr (L/hr)
7.0 HGJAE
No load
0.42 (1.6)
Half load
0.73 (2.8)
Full load
1.22 (4.6)
LP vapor, Gal/hr (L/hr)
6.5 HGJAE
0.52 (1.95)
0.90 (3.4)
1.5 (5.9)
Alternator details
Design: Cummins Onan, revolving field, AC, 2-pole selfexcited, two bearing design
Insulation system and temperature rise: Meets
requirements of NEMA MG-1 and CSA C22.2, Std. 100
Motors and Generators
Cooling: Direct drive centrifugal blower, cast aluminum
housing for excellent heat transfer
Rotor: Laminated electrical steel assembly press-fitted
to shaft, balanced; heavy insulated copper wire windings;
optimized air gap for improved waveform and motor
starting; Class 200 magnet wire
Stator: Laminated electrical steel assembly, skewed for
improved waveform; Class 200 quadrature wire with 70%
Frequency regulation
Voltage regulation
No load/Full load
No load/Full load
5.0%
2.0%
Cummins®, Onan®, the "C" logo, Performance you rely on.TM and Quiet GasolineTM are
servicemarks, trademarks and/or registered trademarks of Cummins Inc.
Specifications are subject to change without notice
©2012 Cummins Power Generation. All Rights Reserved.
A-1441h (3/12)
more insulation over comparable generator sets
Excitation: Capped, digital voltage regulation
DC brushes: Electrographic; long life
Bearing: Double-sealed pre-lubricated ball bearings
Generator set details
Hydraulic pump
- Fixed displacement gear pump, 1.8 Gal/min at 2500 psi
- Hydraulic pump is rated with the pump idle
- When using a non-Cummins Onan pump supplied by
the customer, the hydraulic pump shaft seals must be
capable of operating in a temperature environment of
225° F to 250° F. Seal failure will result in equipment
damage
Frequency regulation
Voltage regulation
Constant load
Constant load
1.7%
1.7%
Dimensions: in (mm)
Basic dimensions
Note: This outline drawing is provided for general reference only and is not intended for design or installation. For more information see
Operation and Installation manuals or obtain drawing 500-3449 and wiring diagram from your distributor/dealer.
Options and accessories
• Remote control start/stop rocker switch
•
•
•
•
(P/N 300-5331)
Remote control with start/stop switch and hour meter
(P/N 300-5332)
Remote control with start/stop switch and DC
voltmeter (P/N 300-5333)
Remote control plug and wire harness
10 ft (P/N 338-3489-01), 30 ft (P/N 338-3489-02)
Remote harness (P/N 300-4946) pigtail harness to
connect to sealed remote connector
Cummins®, Onan®, the "C" logo, Performance you rely on.TM and Quiet GasolineTM are
servicemarks, trademarks and/or registered trademarks of Cummins Inc.
Specifications are subject to change without notice
©2012 Cummins Power Generation. All Rights Reserved.
A-1441h (3/12)
LPG vapor fuel conversion kit (P/N 148-1161)
Under floor mounting kit (P/N 405-6699)
Installation template (P/N 539-2057)
Tailpipe kit 22 in (P/N 155-3481-01),
26
in (P/N 155-3481-02)
• Exhaust tube, straight with flanged end
3
in (P/N 155-2610), 7 in (P/N 155-2424),
12.5 in
(P/N 155-2610-01)
• Exhaust elbow, tight radius 90° to route exhaust through
cutouts (P/N 155-3439)
•
•
•
•
Standards and testing
After sale support
°
°
- Tested at extremes of temperature -20 F to 120 F for
-
starting and operation
Tested installed
Tested with commercial loads
Tested in high humidity conditions
Tested in salt spray conditions
Tested in heavy air borne dust conditions
Field test program
60 Hz models meet applicable U.S. EPA and California
emissions standards
This generator set was designed and manufactured in
facilities certified to ISO 9001
CSA certified for CSA C22.2 Std 100 and Std 14
Warranty policy
The Cummins Onan limited warranty covers virtually
everything except routine maintenance for the first two
years that you own your generator set, or the first 2,000
hours of operation, whichever comes first. In addition, it
includes a free 90-day adjustment policy, which provides
that Cummins Inc. will make minor adjustments to your
new generator set during the first three months you own it
- free of charge!
!
WARNING:
Do not use this generator set on a boat.
Such use may violate U.S. Coast Guard
regulations, and can result in severe
personal injury or death from fire,
explosion, electrocution, or carbon
monoxide poisoning.
!
Largest distributor/dealer support network
Cummins Onan generator sets are supported by the
largest and best trained worldwide certified
distributor/dealer network in the industry. This network of
knowledgeable Cummins Onan distributor/dealers will
help you select and install the right generator set and
accessories to meet the requirements of your specific
application. This same network offers a complete selection
of commonly used generator set maintenance parts,
accessories and products plus manuals and specification
sheets. Plus, they can answer your questions regarding
proper operation, maintenance schedules and more.
Manuals: Operation and installation manuals ship with
the generator set. To obtain additional copies or other
manuals for this model, see your Cummins Onan
distributor/dealer and request the following manual
numbers: Operation (A035D007), Installation (A035D003),
Parts (983-0202 I10), Service (A035D011).
To easily locate the nearest Cummins Onan
distributor/dealer in your area, or for more information,
contact us at 1-800-888-6626 (or 763-574-5000), or visit
www.cumminsonan.com.
WARNING:
Back feed to a utility system can cause
electrocution and/or property damage. Do
not connect to any building electrical
except through an approved device or
after building main breaker is open.
Contact your distributor/dealer for more information
Cummins®, Onan®, the "C" logo, Performance you rely on.TM and Quiet GasolineTM are
servicemarks, trademarks and/or registered trademarks of Cummins Inc.
Specifications are subject to change without notice
©2012 Cummins Power Generation. All Rights Reserved.
A-1441h (3/12)