1 of 4
QUIC K START G U I DE
Model 25-K2
1
Carefully unpack box and make sure you have all items
shown below.
What’s what?
Important components labeled
Unit shown with front panel fully open.
Internal wiring not shown for clarity.
Antenna Cables
Ascent Unit
r
12-V AC/DC Adapter
(PS-12DC1)
I M PO R T A NT !
2
Key
Carriage Bolt
( x4 )
Hex Nut
( x4 )
Wiegand Device Terminals
For wiring to Wiegand-compatible devices
such as a proximity card reader.
See summitcontrol.com/resources.
Status and Event Terminals
Unlock and open front panel
of unit for wiring and setup.
For wiring to check gate status and for
request-to-exit devices. See Page 3.
We recommend mounting Ascent on a
gooseneck pedestal using included hardware.
Power and Relay Terminals
For wiring to power and gate operator
and/or door opener. See Page 2.
If using alternate mounting, two (2)
Ascent 10' Cable Extension (p/n 16-X-EXT)
products should be purchased and installed.
Relay Status LEDs
Relay is active when lit
Failure to do so may result in NO SIGNAL!
Continued on next page...
r
I M PO R TA NT !
Ascent WILL NOT WORK until the
activation process is COMPLETE!
Follow the Activation Guide or call
Summit Control at (844) 259-8265 to
activate your unit.
Ascent Camera
For automatic and on-demand photo capture
SIM Card
W AR NI N G !
AUTOMATIC GATES CAN CAUSE
SERIOUS INJURY OR DEATH!
ALWAYS CHECK that the GATE PATH
IS CLEAR BEFORE OPERATING!
Reversing or other safety devices
should ALWAYS BE USED!
If you have your own SIM card, see Page 4
and follow the instructions entitled,
Installing a Third-Party SIM Card.
C A U TIO N !
Please use all four screws when mounting unit to pedestal. Leave “hockey puck” antenna
in place, even if using extension. Seal any holes or gaps created in unit enclosure.
Failure to follow these instructions can result in damage to the unit!
2 of 4
Q U ICK STA R T G U I DE
Ascent Power and Relay Terminals
POWER
CLOSE
STOP
OPEN
COM
REVERSE LOOP
COM
FREE EXIT
COM
RADIO
COM
GND
POS. (+)
J12
#3
J9
#2
GND
N/C
If plugging into duplex outlet,
remove screw from outlet plate,
and secure with included screw.
J8
Gate Operator / Door Opener
12–24 VAC/DC
DIGITAL INPUTS
GND
J5
COM
J4
N/C
J3
N/O
RELAY B
N/O
RELAY A
POS. (+)
Additional wiring diagrams
can be found on Page 3.
POWER
#1
12–24 VAC/DC
COM
Feed wires through back of unit
and connect as shown.
NEG. (–)
Connect wires
NEG. (–)
3
Model 25-K2
Relay B can be wired to a second device
in the same manner.
OR
12-V AC/DC Adapter
(Model PS-12DC1 included)
+ –
The GROUND terminal is optional unless
required by local code(s). If using, please
connect to earth ground or equivalent.
Third-Party 12–24-VAC/DC
Power Source
S T OP !
Before going forward,
double check wiring and
ensure unit has power!
For additional wiring
options, see Page 3.
© 2018 Security Brands, Inc. All rights reserved.
4
Close and lock front panel.
Consult gate operator or
door opener manual for
exact connections.
Terminals vary widely
across manufacturers
and models.
C A U TIO N !
If you will not be using the 12-V AC/DC adapter,
please go to Page 4 and follow the procedure,
Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a
compatible power source can damage unit!
N
INSTALLATION COMPLETE!
Now follow the Activation Guide to create
an account and begin using Ascent.
QSG-25K2-EN
Rev. B (6/2018)
3 of 4
Q U ICK STA R T G U I DE
A Status Check
Wiring to enable Gate Status Check
CAU T I ON !
The Status Terminals are designed for
low voltage (3 V or less). Check the
voltage on your status wires before
connecting. If it is above 3 V, you will
need to contact Technical Support.
Ascent Status and
Event Terminals
Exceeding 3 V can damage Ascent!
Model 25-K2
B Event Input
Wiring for accessories such as a request-to-exit device
Ascent Status and Event Terminals
Optional
wire
splices
N/O
GND
CLOSE
OPEN
N/C
GND
J6
OPEN
J13
CLOSE
J7
GND
J6
GND
J13
N/O
J7
GND
EVENT
CLOSE
GATE 2
OPEN
GATE 1
CLOSE
EVENT
GND
GATE 2
OPEN
GATE 1
Close Limit Switch
N/O
COM
N/C
Open Limit Switch
N/O
COM
Gate Operator
Request-to-Exit
(if equipped with limit switches)
(S-RTE-P is shown)
4 of 4
Q U ICK STA R T G U I DE
Model 25-K2
IM P OR T ANT !
r
Using a
Third-Party
Power Source
(Optional)
If you would like to use a third-party
power source, such as solar, verify that
it conforms to the following specs:
Input
Current Draw
1
Installing a
Third-Party
SIM Card
(Optional)
12–24 VAC/DC
no more than 10% beyond this range
less than 190 mA @ 12 VDC
less than 160 mA @ 24 VDC
Connect wires to unit as shown in
3a Step 3.
Push existing SIM card in until it
unlocks with “click” sound.
? NEED HELP
© 2018 Security Brands, Inc. All rights reserved.
Connect wires to your power source,
3b making sure you connect positive to
positive and negative to negative.
2
Remove existing SIM card and locate
new SIM card.
C A U TIO N !
Double check that you’ve wired from
positive on Ascent to positive on your
power source and negative on Ascent to
negative on your power source.
Reverse polarity can damage Ascent!
3
Insert new SIM card until it locks in
place with “click” sound.
Call (844) 259-8265
Email [email protected]
We are available Mon–Fri / 8am–5pm Central
QSG-25K2-EN
Rev. B (6/2018)
">