Miller Electric | MOG-400-PR | L&T Switchgear Elsectrical Standard Products Price List

, Vadodara, Delhi & Kolkata
,
cover:
Low Voltage & Medium Voltage Switchgear
Switchboard Electrical Design
AC Drives & Building Management Solutions
Protective Relays, Earthing & Harmonics
Energy Conservation & Management
New
Pune
Larsen & Toubro Limited
Switchgear Training Centre
T-156/157, MIDC, Bhosari,
Pune: 411 026.
Tel: (020) 2712 0037 / 2712 0653
Fax: (020) 2712 2933
E-mail : STC-PUNE@LNTEBG.COM
Lucknow
Larsen & Toubro Limited
Switchgear Training Centre
C-6&7, UPSIDE, P.O. Sarojini Nagar,
Lucknow: 226 008.
Tel: (0522) 247 6110 / 099355 63239
Fax: (0522) 247 6015
E-mail : STC-LUCKNOW@LNTEBG.COM
New
Coonoor
Larsen & Toubro Limited
Switchgear Training Centre Ooty-Coonoor
Main Road, Yellanahalli
P.O., The Nilgiris - 643 243.
Tel: (0423) 251 7107
Fax: (0423) 251 7158
E-mail : STC-COONOOR@LNTEBG.COM
Vadodara
Larsen & Toubro Limited
Switchgear Training Centre
Behind L&T Knowledge City,
Near Village Ankhol,
Vadodara - 390 019.
Tel: +91 265 245 7805
E-mail : STC-VADODARA@LNTEBG.COM
Delhi
Larsen & Toubro Limited
Switchgear Training Centre
32, Shivaji Marg, Near Moti Nagar Metro Station
P.O. Box 6223, New Delhi: 110015.
Tel: +91 011 41419515 / 41419516 / 41419500
Fax: +91 011 41419600
E-mail: STC-DELHI@LNTEBG.COM
New
Kolkata
Larsen & Toubro Limited
Switchgear Training Centre
4th Floor, 3-B, Shakespeare Sarani,
Kolkata: 700071
Tel: +91 033 44002151
E-mail: STC-KOLKATA@LNTEBG.COM
Description
Page No.
Contactors
2
Bimetal Overload Relays
10
Control Accessories
13
Motor Protection Circuit Breakers
14
Motor Starters
17
Digital Soft Starters
20
Switch-Disconnector-Fuse Units, SDs & HRC Fuses
22
On Load Changeover Switch-Disconnectors
28
Moulded Case Circuit Breakers
29
Air Circuit Breakers
44
Reactive Power Management Solutions
55
Digital Protective Relays
61
Electronic Metering Devices
65
Programmable Logic Controllers (PLC)
68
Human Machine Interface
69
Modular Devices
71
Type 2 co-ordination selection charts for Fuse Protected System
78
Discontinued Products
81
Please contact the nearest branch office for
Prices of the following products :
l
Distribution System Components such as 6kA MCBs, EL + MCB etc.
l
AC Variable Frequency Drives
l
3 Phase Squirrel Cage Induction Motor
l
Servo & Motion Control Solutions
l
Wires, Cables and Flat Cables
l
Busbar Trunking Systems
l
Building Automation Products & Solutions
l
Home Automation Products & Solutions
l
Rotary Switches
l
Modular Remote Control Units & Indicating Units
l
Timing Devices & Supply Moniters
l
Cable Ducts & LB Series Switches
l
Modular Switches and Sockets
l
Diva Solar Lantern
l
Medium Voltage AIS upto 36kV
Note: Product photographs shown, are for representative purposes only.
L&T, ESP 01.11.2013
Search for 'ProductWhiz' on Google Play and Blackberry World
or
Scan this through your mobile to download ProductWhiz now!
Contactors
Power Contactors
2 Pole
l
3 Pole
MNX
4 Pole
l
MX Power
l
MNX
l
l
MO
MDX (DC Control)
l
ML
l
MCX
Control Relays
(Auxiliary Contactors)
l
MX0 (Mini)
l
MN0
Capacitor Duty
Contactors
l
Definite Purpose
Contactors
MO C
l
Single Pole - MR
l
MK1
l
MU
3 Pole Power Contactors
3 Pole Power Contactors - Type MNX
3 Pole Power Contactors - Type MO
Features
Features
l
l
l
l
l
l
l
Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
Range from 9A – 650A AC-3
Entire range is UL listed
Click fit type construction up to 40A
Coil on top design in 95A and above
Spares available for entire range
l
l
l
l
l
l
MNX 22
MNX 40
MNX 80
MNX 140
MNX 225
MNX 650
AC3
Rating
(A)
AC1
Rating
(A)
Type
9
25
MNX 9
12
18
2
Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
Range from 9A - 110A AC-3
Compact dimensions saving panel space
Lug less termination for contactors above 50A
Standardized accessories throughout the range
Low pick-up VA consumption
RoHS compliant
MO 9
Std.
Pkg.
(Nos.)
MO 45
AC3
Rating
(A)
AC1
Rating
(A)
10
9
10
12
810
10
M.R.P.
(`)
Per Unit
Aux.
Contacts
Cat. No.
1 NO
CS94106
720
1 NC
CS94107
720
CS94108
MO 70
MO 110
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Type
Aux.
Contacts
Cat. No.
30
MO 9
#
CS94564
695
10
35
MO 12
#
CS94565
800
10
18
40
MO 18
#
CS94566
945
10
30
MNX 12
1 NO
1 NC
CS94109
810
10
25
45
MO 25
#
CS94567
1325
10
30
MNX 18
1 NO
CS94100
945
10
32
50
MO 32
#
CS94568
2880
10
1 NC
CS94101
945
10
40
50
MO 40
#
CS94569
4345
10
CS94980
1095
10
45
50
MO 45
#
CS94570
4865
10
22
32
MNX 22
1 NO
1 NC
CS94981
1095
10
50
65
MO 50
#
CS94572
4910
1
25
45
MNX 25
#
CS94110
1130
10
60
80
MO 60
#
CS94573
5940
1
32
55
MNX 32
#
CS94111
2510
10
70
100
MO 70
#
CS94574
6865
1
40
55
MNX 40
#
CS94190
4010
10
80
125
MO 80
#
CS94576
8520
1
45
85
MNX 45
2 NO + 2 NC
ST19000
5495
1
95
125
MO 95
#
CS94577
10340
1
50
85
MNX 50
2 NO + 2 NC
ST19001
5535
1
110
140
MO 110
#
CS94578
12475
1
70
100
MNX 70
2 NO + 2 NC
ST19002
7585
1
80
100
MNX 80
2 NO + 2 NC
ST19003
9325
1
95
160
MNX 95
2 NO + 2 NC
CS94136
11235
1
110
160
MNX 110
2 NO + 2 NC
CS94137
13345
1
140
160
CS94138
17530
1
185
250
MNX 140 2 NO + 2 NC
MNX 185 2 NO + 2 NC
CS94139
23065
1
225
300
CS94140
25145
1
265
350
MNX 225 2 NO + 2 NC
MNX 265 2 NO + 2 NC
CS94142
29775
1
325
400
CS94143
34180
1
400
425
MNX 325 2 NO + 2 NC
MNX 400 2 NO + 2 NC
CS94144
44150
1
550
650
CS94145
69145
1
650
800
MNX 550 2 NO + 2 NC
MNX 650 2 NO + 2 NC
CS96327
88540
1
Notes:
1) # Add-on blocks can be ordered separately
2) For ordering MNX/MO add-on aux contact blocks, please refer page No. 6
3) For ordering MNX surge suppressor and MNX/MO MIL kit, please refer page No. 7
4) For Ordering Suffix, please refer page No. 7, Table A
5) Standard coil voltage: MNX/MO - 110V, 220V, 240V and 415V, 50Hz.
L&T, ESP 01.11.2013
3 Pole Power Contactors
New
2 Pole Power Contactors
New
3 Pole Power Contactors - Type MDX
(DC Control)
2 Pole Power Contactors - Type MNX
Features
Features
l
l
l
l
l
Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
Range from 9 - 110A AC-3
Built in surge suppressor for MDX 9 - 38
IP20 connection security for MDX 9 - 38
l
l
l
l
l
Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
Range from 9A – 550A AC-3
DC ratings available
Click fit type construction up to 40A
Coil on top design in 95A and above
Common spares and accessories as MNX 3P
AC1
AC3
Rating Rating
(A)
(A)
MDX 25
MDX 38
AC3
Rating
(A)
AC1
Rating
(A)
Type
9
25
MDX 9
1 NO
12
28
MDX 12
18
32
25
MDX 110
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
CS96564
1420
1
1 NO
CS96565
1500
1
MDX 18
1 NO
CS96566
1730
1
32
MDX 25
1 NO
CS96567
2430
1
32
56
MDX 32
#
CS96552
4850
1
38
56
MDX 38
#
CS96553
5670
1
50
90
MDX 50
#
CS96554
7980
1
65
110
MDX 65
#
CS96555
9040
1
80
125
MDX 80
#
CS96556
11055
1
95
125
MDX 95
#
CS96557
13795
1
110
125
MDX 110
#
CS96558
14450
1
Aux.
Contacts
Cat. No.
Notes:
1) # Add-on blocks can be ordered separately.
2) For ordering MDX/MNX add-on aux contact blocks, please refer page No. 6
3) For ordering MDX/MNX surge suppressor and MIL kit, please refer page No. 7
4) For ordering Suffix, please refer page No. 7, Table A
5) Standard coil voltage: MDX - 24V, 48V, 110V and 220V DC.
6) Standard coil voltage: MNX - 110V, 220V, 240V and 415V, 50Hz.
Type
Aux.
Contacts
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
9
25
MNX 9-2P
1 NO
CS90232
540
10
12
30
MNX 12-2P
1 NO
CS90234
610
10
18
30
MNX 18-2P
1 NO
CS90236
710
10
22
32
MNX 22-2P
1 NO
CS90238
820
10
25
45
MNX 25-2P
#
CS90240
850
10
32
55
MNX 32-2P
#
CS90241
1885
10
40
55
MNX 40-2P
#
CS90242
3010
10
45
85
MNX 45-2P
#
CS94060
3845
1
50
85
MNX 50-2P
#
CS94061
4325
1
70
100
MNX 70-2P
#
CS94062
5290
1
80
100
MNX 80-2P
#
CS94063
6520
1
95
160
MNX 95-2P
2 NO + 2 NC
CS94064
7895
1
110
160
MNX 110-2P 2 NO + 2 NC
CS94065
9395
1
140
160
MNX 140-2P 2 NO + 2 NC
CS94066
12265
1
185
250
MNX 185-2P 2 NO + 2 NC
CS94978
16190
1
225
300
MNX 225-2P 2 NO + 2 NC
CS94979
17685
1
265
350
MNX 265-2P 2 NO + 2 NC
CS94067
21050
1
325
400
MNX 325-2P 2 NO + 2 NC
CS94068
24075
1
400
425
MNX 400-2P 2 NO + 2 NC
CS94069
30850
1
550
650
MNX 550-2P 2 NO + 2 NC
CS90243
48500
1
3 Pole Power Contactors
3 Pole Power Contactors - Type ML
3 Pole Power Contactors - Type MX Mini
Features
Features
l
l
l
l
Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
Range from 25 - 300A AC-3
Robust and suitable for hostile applications
l
l
l
ML 1.5
ML 3
ML 6
AC3
Rating
(A)
AC1
Rating
(A)
Type
Aux.
Contacts
25
25
ML 1.5
32
40
ML 2
40
45
70
Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
Enclosed construction providing compactness and convenience
Base as well as DIN Rail mounting facility
Inbuilt Surge Suppressor in MX DC
ML 12
MX 06
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
2 NO + 2 NC
SS91851
2230
1
2 NO + 2 NC
SS90701
4140
1
6A
20A
MX 06
1 NO
CS94012
655
10
ML 3
2 NO + 2 NC
SS90721
6110
1
6A
20A
MX 06
1 NC
CS94013
655
10
100
ML 4
2 NO + 2 NC
SS90910
9990
1
9A
20A
MX 09
1 NO
CS94014
690
10
110
125
ML 6
2 NO + 2 NC
SS90921
15770
1
9A
20A
MX 09
1 NC
CS94015
690
10
200
250
ML 10
2 NO + 2 NC
SS90935
34840
1
12A
20A
MX 12
1 NO
CS94016
760
10
300
400
ML 12
2 NO + 2 NC
SS91010
37510
1
12A
20A
MX 12
1 NC
CS94017
760
10
Notes:
1) For ordering ML/MX add-on aux contact blocks, please refer page No. 6
2) For ordering MX surge suppressor and MIL kit, please refer page No. 7
3) For Ordering Suffix, please refer page No. 7, Table A
4) Std. Coil Voltage: ML - 110V, 220V, 240V and 415V, 50Hz
L&T, ESP 01.11.2013
AC3
Rating
(A)
AC1
Rating
(A)
Type
Aux.
Contact
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
For AC control (Std. Coil Voltage - 24, 110, 240, 415V, 50Hz)
For DC control (Std. Coil Voltage - 24, 110, 220V)
6A
20A
MX 06
1 NO
CS94021
980
10
6A
20A
MX 06
1 NC
CS94022
980
10
9A
20A
MX 09
1 NO
CS94023
1030
10
9A
20A
MX 09
1 NC
CS94024
1030
10
12A
20A
MX 12
1 NO
CS94025
1125
10
12A
20A
MX 12
1 NC
CS94026
1125
10
3
4 Pole Power Contactors & AST System Components
4 Pole Power Contactors - Type MCX
Auto Source Transfer Controller
Features
l
l
l
Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1
Range from 16A – 800A AC-1
Wide operating band up to 100A AC-1
MCX 22
New
New
MCX 34
MCX 47
AC-1
Rating
(A)
Type
Aux
Contacts
Cat. No.
16
MCX 01
#
CS97009
AuXC-1000L
Std.
Pkg.
(Nos.)
M.R.P.
(`)
Per Unit
975
10
1095
10
CS97011
1175
10
CS97012
1830
10
CS97013
2150
1
#
CS97014
4265
1
#
CS97015
5675
1
MCX 21
#
CS97016
6515
1
25
MCX 02
#
32
MCX 03
#
40
MCX 04
#
50
MCX 11
#
63
MCX 12
80
MCX 13
80
CS97010
100
MCX 22
#
CS97017
6870
1
New 130
MCX 23
#
CS97018
9100
1
130
MCX 31
1 NO + 1 NC
CS97019
10435
1
160
MCX 32
1 NO + 1 NC
CS97020
14395
1
200
MCX 33
1 NO + 1 NC
CS97021
17710
1
255
MCX 34
1 NO + 1 NC
CS97022
New
AuXC-1000
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std. Pkg.
(Nos.)
AuXC-1000L
ST80024OOOO
39790
1
AuXC-1000
ST80230OOOO
47950
1
Can be used along with U-POWER Omega ACBs,
MCCBs, & MCX contactors
4 Pole Mechanically
Interlocked Contactors
Two MCX 12
Aux
Contacts
Cat. No.
M.R.P.
(`)
Per Unit
Std. Pkg.
(Nos.)
Two MCX 11
#
CS94362
5560
1
1
Two MCX 12
#
CS94365
9790
1
34215
1
New Two MCX 13
#
CS94367
12610
1
18975
325
MCX 41
2 NO + 2 NC
CS97023
360
MCX 42
2 NO + 2 NC
CS97024
37110
1
400
MCX 43
2 NO + 2 NC
CS97025
43855
1
500
MCX 44
2 NO + 2 NC
CS97026
54505
1
600
MCX 45
2 NO + 2 NC
CS97027
64940
1
700
MCX 46
2 NO + 2 NC
CS97028
77695
1
800
MCX 47
2 NO + 2 NC
CS94291
100150
1
Type
Notes:
1) # Add on blocks can be ordered separately.
2) For ordering MCX add-on aux contact blocks, please refer page No. 6
3) For ordering MCX surge suppressor and MIL kit, please refer page No. 7
4) For Ordering Suffix, please refer page No. 7, Table A
5) Std. Coil Voltage: MCX - 220V, 240V and 415V 50Hz
6) *Ordering Suffix for MCX 21 / 22 / 23; FOOO - 240V AC, ROOO - 415V AC
Control Relays (Auxiliary Contactors)
Type MX0
l
l
l
MX0 40E
Rated
Current
Type MN0
Features
l
Conforms to IS / IEC 60947-4-1 &
IEC 60947-4-1
Alphanumeric terminal markings
Available with AC or DC control
Inbuilt Surge Suppressor in MX DC
Description
Cat. No.
M.R.P.
(`)
Per Unit
MN0 22E
Std.
Pkg.
(Nos.)
MX0 40E (4 NO)
CS94018
810
10
MX0 31E (3 NO + 1 NC)
CS94019
810
10
MX0 22E (2 NO + 2 NC)
CS94020
810
10
MX0 13E (1 NO + 3 NC)
CS94041
810
10
MX0 04E (4 NC)
CS94042
810
10
For DC control std. Coil Voltage - 24, 110, 220V
AC-15
4A
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz
For AC control std. Coil Voltage - 24, 110, 240, 415V, 50Hz
AC-15
4A
Rated
Current
MN0dc 22E
MX0 40E (4 NO)
CS94027
1090
10
MX0 31E (3 NO + 1 NC)
CS94028
1090
10
MX0 22E (2 NO + 2 NC)
CS94029
1090
10
MX0 13E (1 NO + 3 NC)
CS94043
1090
10
MX0 04E (4 NC)
CS94044
1090
10
AC-15
4A
MN0 40E (4 NO)
SS94660
955
10
MN0 31E (3 NO + 1 NC)
SS94661
955
10
MN0 22E (2 NO + 2 NC)
SS94662
955
10
MN0 13E (1 NO + 3 NC)
SS94663
955
10
MN0 04E (4 NC)
SS94664
955
10
For DC control std. Coil Voltage - 24, 110, 220V
AC-15
4A
MN0 40E (4 NO)
SS94665
1580
10
MN0 31E (3 NO + 1 NC)
SS94666
1580
10
MN0 22E (2 NO + 2 NC)
SS94667
1580
10
MN0 13E (1 NO + 3 NC)
SS94668
1580
10
MN0 04E (4 NC)
SS94669
1580
10
Notes:
1) For Ordering Suffix, please refer page No. 7, Table A
2) 5 NC & above combinations are not recommended for MX0 DC Control Contactors
3) 1 NO + 3 NC, 4 NC add on block combinations are not recommended for MX0 DC Control Contactors. For Example, In MX0 DC control Contactors, 4NO + 4NC
combination can be achieved with 2NO + 2NC aux contactor and 2NO + 2NC Add on block and not with 4NO standalone contactor plus 4NC add on block
4
L&T, ESP 01.11.2013
Capacitor Duty Contactors
Capacitor Duty Contactors - Type MO C
MO C25
MO C50
kVAR Rating
@ 415V,
3Ph, 50Hz
Type
8.5
MO C8.5
12.5
MO C12.5
15
MO C15
20
MO C20
25
33.5
MO C33.5
50
MO C50
70
80
l
CS96320
1740
1
l
CS96337
1740
1
l
1NO
CS96321
1955
1
l
1NC
CS96338
1955
1
1NO
CS90019
2760
1
1NC
CS90020
2760
1
1NO
CS90021
3185
1
1NC
CS90022
3185
1
1NO
CS96322
3610
1
1NO
1NC
MO C70
MO C80
Features
Std.
Pkg.
(Nos.)
Cat. No.
MO C25
MO C80
M.R.P.
(`)
Per Unit
Built-in
Auxiliary
Contacts
1NC
CS96339
3610
1
1NO
CS96323
6490
1
1NC
CS96340
6490
1
1NO
CS96324
9750
1
1NC
CS96341
9750
1
1NO
CS96325
11715
1
1
1NC
CS96342
11715
1NO
CS96326
12690
1
1NC
CS96343
12690
1
l
l
MO C Range available from 8.5 - 80 Kvar
Delatching auxiliary contacts
Encapsulated resistor assembly
Separate termination for damping resistors
Lug less termination for MO C33.5 to MO C80
RoHS compliant
For Reactive Power Management Solutions,
please refer page No. 55-59
Note :
1) # Add on blocks can be ordered separately
For Add on block Cat No. refer page No. 6
2) For ordering suffix, please refer page No. 7, Table A
3) For ordering spare coils, please refer page No. 8
Definite Purpose Contactors
Type MU
Type MK1
MU 1
MU 2
MK 1
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
MU 1
CS94007
1525
10
MU 2
CS94008
2065
10
AC3
Rating
(A)
Type
16A
25A
Type
AC3
Rating
(A)
MK 1
15A
Motor Output
3 Phase
415V, 50Hz
HP
KW
7.5
5.5
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SS95200
985
10
For Overload Relays type MK1, please refer page No. 11
For Ordering Suffix, please refer page No. 7, Table A
(For 360V wide band, Ordering Suffix - SOOO)
For Overload Relays type MU refer page No.11
For Ordering Suffix please refer page No. 7, Table A
Single Pole Contactors - Type MR
Features
l
l
Wide and chatter free operating band
High AC-1 rating for single phase applications
MR 11W
MR 13
(Wide band coil)
MR 11NW
SPN (Wide band coil)
AC3 Rating
(A)
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
25A
MR 11W
CS94176
660
10
25A
MR 11NW
CS94178
710
10
40A
MR 13
CS94992
725
40
Ordering Suffix BOOO - 240V, 50Hz
L&T, ESP 01.11.2013
5
Accessories - Add-on Auxiliary Contact Blocks
Front Mounting add-on block
MNX / MCX
Front Add-on Block
Front
Mounting
MDX Front
Add-on Block
MO
Front Add-on Block
MX Front
Add-on Block
MN0 Front
Add-on Block
Suitable for
MNX 9-40 /
MCX 01-23
M.R.P.
(`)
Per Unit
MO 9-110
M.R.P.
(`)
Per Unit
MDX
M.R.P.
(`)
Per Unit
MX
M.R.P.
(`)
Per Unit
MN0
M.R.P.
(`)
Per Unit
4 NO
CS94112
400
CS94594
400
CS94033
350
SS94083
360
3 NO + 1 NC
CS94113
400
CS94595
400
CS94034
350
SS94084
360
2 NO + 2 NC
CS94114
400
CS94596
400
CS94035
350
SS94085
360
1 NO + 3 NC
CS94115
400
CS94597
400
CS94036
350
SS94086
360
4 NC
CS94116
400
CS94598
400
CS94037
350
SS94087
360
2 NO
CS94117
270
CS94591
270
CS94030
225
SS94080
240
1 NO + 1 NC
CS94118
270
CS94592
270
CS94031
225
SS94081
240
2 NC
CS94119
270
CS94593
270
CS94032
225
SS94082
240
1 NO
CS94120
130
CS94585
130
SS94715
120
1 NC
CS94121
130
CS94586
130
SS94716
120
CS96569
CS96568
CS96586
525
305
170
Side Mounting add-on block
MNX/MCX
Side Add-on Block
Suitable for
Side
Mounting
Aux Contact
MNX 9-40 /
MCX 01-04
M.R.P.
(`)
Per Unit
MNX 45-80 /
MCX 11-23
M.R.P.
(`)
Per Unit
MCX 31-34
M.R.P.
(`)
Per Unit
MNX 95-650 /
MCX 41-47
M.R.P.
(`)
Per Unit
CS94205
485
CS94205
485
CS94206
485
CS94207
485
CS94208
485
First left
1 NO + 1 NC
CS94220
400
CS94201
430
First Right
1 NO + 1 NC
CS94221
400
CS94202
430
Second Left
1 NO + 1 NC
CS94203
430
Second right
1 NO + 1 NC
CS94204
430
CS94207
485
Side Mounting add-on block
MDX
Add-on Block
MO/MO C
Left Add-on Block
Suitable for
Side
Mounting
Aux Contact
MO 9-110
M.R.P.
(`)
Per Unit
MO C 8.5-80
M.R.P.
(`)
Per Unit
First left
1 NO + 1 NC
CS94580
400
CS94580
400
First Right
1 NO + 1 NC
CS94581
400
CS94581
400
Second Left
1 NO + 1 NC
CS94582
400
CS94582
400
Second right
1 NO + 1 NC
CS94583
400
CS94583
400
Side Mounting add-on block
MDX 9-110
M.R.P.
(`)
Per Unit
ST94985
630
For MR & MU
ML
Add-on Block
Side
Mounting
MR 1NO
Suitable for
Aux Contact
Left
1 NO + 1 NC
Right
1 NO + 1 NC
ML 4/6
M.R.P.
(`)
Per Unit
SS91494
ML 10/12
M.R.P.
(`)
Per Unit
500
SS91474
525
Description
Add-on Single pole
For
Contactor
MR
Side mounted auxiliary
MU 1 / MU 2
contact block
Contacts
Type
Cat. No.
1 NO
Std.
M.R.P.
Pkg.
(`)
(Nos.)
Per Unit
CS94179
165
10
1 NO + 1 NC SS94072
150
10
SS94074
125
10
1NC
Note: Ordering Suffix for Add-on blocks : OOOO
6
L&T, ESP 01.11.2013
Accessories - Surge Suppressors
For MX, MNX, MDX & MCX
MNX S1
MNX S3
For MN0
MNX S4
For Contactor
MX 06 to MX 09 / MX 0 AC
MNX 9 - 40 / MCX 01 - 04
MNX 45 - 80 / MCX 11 - 22
MNX 95 - 225 / MCX 31 - 34
MNX 265 - 400 / MCX 41 - 44
MDX 50 - 110
MX - S1
Cat. No.
M.R.P.
(`)
Per Unit
CS94039*
CS94166*
CS94163*
CS94164#
CS94165#
CS96571**
345
360
395
1300
1760
360
MN - S1
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
MN0 AC
SS94623
360
1
MN0 DC
SS94781
360
1
Ordering Suffix 110-240V : BOOO
415V : DOOO
24-48VDC : 5OOO
110-220VDC : 2OOO
Ordering Suffix * 110-240V: BOOO, 415V: DOOO ** : OOOO
# 110V: AOOO, 220-240V: BOOO, 360-525V: DOOO
*MX DC has in-built surge suppressor
Accessories - Mechanical Interlock Kits & Spreader Link Kit
Mechanical Interlock Kit for MX, MO, MDX,
MNX & MCX
MNX M1
(MNX 9-40)
MCX M3
(MCX 21-22)
MO Spreader Link Kit
MX-M1
(MX0 / MX06-MX09)
MO MI Kit
(MO 9-110)
For Contactor
Cat. No.
M.R.P.
(`)
Per Unit
MX 06 to MX 09 / MX 0
MO 9 - 110*
MDX 9 - 38
MDX 50 - 110
MNX 9 - 40
MNX 45 - 80
MNX 95 - 140
MNX 185 - 225
MNX 265 - 650
MCX 01 - 04
MCX 21 - 22
MCX 31 - 34
MCX 41 - 47
CS94038
CS94584
CS96572
CS96573
CS94126
CS94197
CS94198
CS94199
CS94200
CS94126
CS93095
SS94992
CS94301
345
450
400
1225
390
1570
2480
2830
3210
390
2485
2665
4320
For Contactor
Cat. No.
M.R.P.
(`)
Per Unit
MO 9 - 45
CS94274OOOO
355
Note: Spreader Link Kit consists of six terminals
* MO MIL Kit contains inbuilt 2 NC Contacts
Note: Ordering Suffix for Mechanical Interlock Kits : OOOO
Ordering Suffix for Standard Coil Voltages
Table A
Ordering Suffix for Standard Coil Voltages
DC Control*
AC Control
Voltage (V)
Suffix
Voltage (V)
Suffix
24
GOOO
24
4OOO
42
HOOO
48
5OOO
48
JOOO
110
1OOO
110
AOOO
220
2OOO
220
KOOO
240
BOOO
360
COOO
380
LOOO
415
DOOO
440
POOO
525
MOOO
L&T, ESP 01.11.2013
Note: * for MX DC, MDX, MX0 DC & MN0 DC
7
Spares
Spare Contact Kit and Spare Coil
Spare Contact Kit and Spare Coil
ML Spare Kits
MNX Spare Coils
MNX Spare Kits
ML Spare Coils
MU 2
CS94011
985
ML 1.5
SS95305
1415
ML 2
SS95307
2215
ML 3
SS95309
3765
ML 4
SS95311
5875
ML 6
SS95313
10240
ML 10
SS95315
20090
ML 12
SS95317
24900
MN 0 ac
-
-
MN 0 dc
-
MR
-
Type
Spare Coil
M.R.P.
Cat. No.
(`)
Per Unit
CS94009
440
SS90873
590
SS90545
960
SS91258
1840
MO 12
CS96381
635
MO 18
CS96382
695
MO 25
CS96383
795
MO 32
CS96384
1585
MO 40
CS96385
2365
MO 45
CS96386
2745
MO 50
CS96387
2805
MO 60
CS96388
3155
SS91011
4025
SS94191
460
MO 70
CS96389
3920
-
SS94651
850
MO 80
CS96390
4465
-
CS94102
350
MO 95
CS96391
5455
MO 110
CS96392
6590
MNX 9
CS94123
490
MNX 12
CS94124
635
MNX 18
CS94125
695
MNX 22
CS94269
715
MNX 25
CS94127
795
MNX 32
CS94128
1485
MNX 40
CS94147
2365
MNX 45
CS94149
2745
MNX 50
CS94150
2805
MNX 70
CS94151
3920
MNX 80
CS94152
5135
MNX 95
CS94153
5775
MNX 110
CS94154
7355
MNX 140
CS94155
9900
MNX 185
CS94156
12215
MNX 225
CS94157
13870
MNX 265
CS94159
16715
MNX 325
CS94160
20495
MNX 400
CS94161
26330
MNX 550
CS94162
35410
MNX 650
CS96336
47455
MO C8.5 - 25
CS96317
M.R.P.
(`)
Per Unit
440
MO C33.5 - 50
CS96318
1390
MO C70 - 80
CS96319
2140
Cat. No.
Front housing & Moving bridge kit and
Combination coil with timer for
ML contactor
MNX Contactors
MO C Spare Coils
Type
MO 9
Spare Contact kit
M.R.P.
Cat. No.
(`)
Per Unit
490
CS96380
Type
MO Contactors
MU 1
Spare Contact kit
M.R.P.
Cat. No.
(`)
Per Unit
580
CS94010
MCX Spare Kits
Front housing and moving bridge kit
MCX 01-04
-
-
ST28733
400
MCX 11
CS94077
1590
ML 1.5
ST28734
400
MCX 12
CS94078
2565
ML 2/ ML 3
ST23866
550
MCX 21
CS94330
3855
ML 4/ ML 6
ST28735
1000
MCX 22
CS94331
4440
MCX 31
CS94081
6440
MCX 32
CS94082
7885
MCX 33
CS94083
9915
MCX 34
CS94084
11170
MCX 41
CS94295
20075
MCX 42
CS94296
25475
MCX 43
CS94297
28575
MCX 44
CS94298
33660
MCX 45
CS94299
37735
MCX 46
CS94300
MCX 47
-
42570
-
Cat. No.
ML 0
ML 1
Combination coil with timer
Type
Cat. No.
ML 2
SS90650
Note :
1) Ordering Suffix for Spare Contact kit - OOOO
2) For Spare Coil Ordering Suffix refer page No. 7, Table A
M.R.P.
(`)
Per Unit
1890
MCX Contactors
ST28732
M.R.P.
(`)
Per Unit
400
Type
Spare Coil
Cat. No.
M.R.P.
(`)
Per Unit
CS96317
440
CS96318
1390
CS96319
2140
CS94105
440
CS94192
1390
CS94196
2140
CS94194
3930
CS94195
4515
CS94193
14675
CS94105
440
CS94009
440
ST91291*
1390
CS94196
2140
CS94195
4515
CS94193
14675
* Ordering Suffix for 240V AC - FOOO
8
L&T, ESP 01.11.2013
Bimetal Overload Relays
Type MN
Type RTO
Features
Features
l
l
l
l
l
Available in 3 frame sizes from 0.2-570 A
Ambient temperature compensated up to 55оC
Built in Single Phasing protection
Manual and auto reset mode
l
l
l
l
MN 2
MN 5
Type of
Mounting
(Operation)
MN 12
Ambient temperature compensated upto 55oC
Built in Single Phasing protection
Manual and auto reset mode
Front access to START and STOP/RESET buttons
Sealable in OFF condition
MN 12L
Std.
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
CS96355OOFO
1275
10
0.31 - 0.55
CS96355OOGO
1275
10
10
0.55 - 0.85
CS96355OOJO
1275
10
1125
10
0.78 - 1.2
CS96355OOLO
1275
10
SS94141OOMO
1125
10
1.2 - 2.0
CS96355OONO
1275
10
1.4 - 2.3
SS94141OOPO
1125
10
1.9 - 2.8
CS96355OOPO
1275
10
2 - 3.3
SS94141OOQO
1135
10
2.4 - 3.6
CS96355OOQO
1290
10
3-5
SS94141OOSO
1135
10
3.5 - 5.2
CS96355OOSO
1290
10
4.5 - 7.5
SS94141OOUO
1135
10
4.6 - 6.7
CS96355OOTO
1290
10
6 - 10
SS94142OOVO
1135
10
6.7 - 9.7
CS96355OOVO
1290
10
9 - 15
SS94142OOBO
1155
10
8.5 - 12.5
CS96355OOAO
1310
10
14 - 23
SS94144OODO
1235
10
12.5 - 18.5
CS96356OOCO
1400
10
20 - 33
SS94145OOEO
1815
10
17 - 25.5
CS96356OODO
1400
10
24 - 40
SS94145OOFO
1815
10
25 - 37
CS96356OOEO
2060
10
35 - 45
CS96356OOGO
2060
10
Relay Range
(A)
Cat. No.
0.2 - 0.33
SS94141OOEO
1125
0.3 - 0.5
SS94141OOGO
0.45 - 0.75
Type of
Mounting
(Operation)
Relay Range
(A)
Cat. No.
10
0.23 - 0.41
1125
10
SS94141OOJO
1125
0.6 - 1
SS94141OOKO
0.9 - 1.5
MN 2
(Directly
Operated)
Direct
mounting
on
MNX 9 - 40
RTO - 1
(Directly
Operated)
Direct
Mounting
on
MO 9 - 45
MN 5
(Directly
Operated)
Direct
Mounting on
MNX 45 - 80
20 - 33
SS94136OOEO
2085
10
30 - 50
SS94136OOGO
2385
10
45 - 75
SS94137OOJO
3435
10
66 - 110
SS94137OOKO
3560
10
MN 12
(CT Operated)
Separate
Mounting
(CT Operated)
Separate
Mounting
42 - 69
SS94138OOHO
6220
1
60 - 100
SS94138OOKO
6220
1
90 - 150
SS94138OOMO
6220
1
135 - 225
SS94138OOPO
6530
1
180 - 300
SS94139OOQO
7495
1
270 - 450
SS94139OORO
MN 12L#
8160
1
42 - 69
SS94127OOHO
9355
1
60 - 100
SS94127OOKO
9355
1
90 - 150
SS94127OOMO
9355
1
135 - 225
SS94127OOPO
9355
1
180 - 300
SS94127OOQO
9355
1
340 - 570
SS94127OOSO
9355
1
Modular Load Feeder
RTO Relays can be directly mounted onto MO contactors.
This along with the standardized accessories of MO provides
you a complete modular feeder solution.
# For motors with longer starting time (Trip class 30)
Note : 1) MN 5 & MN 12 Relays of lower ratings available on request
Mini Motor Protection Relay
Features
l
l
l
l
10
Selectable trip class 10A, 10, 20 and 30.
In-built CT (1A - 88A)
Test facility
Protection
- Locked Rotor
- Thermal Overload
- Earth Fault
- Single phasing
- Under current
- Current unbalance
- Phase sequence reversal
Model
Thermal
O/L Range
MPR300
1-2.75
Aux. Supply: 240 V AC
Aux. Supply: 110 V AC
M.R.P.
M.R.P.
(`)
(`)
Cat. No.
Cat. No.
Per Unit
Per Unit
MPR300BE010 5700 MPR300BB010
5700
MPR301
2-5.5
MPR301BE020
5700
MPR301BB020
5700
MPR302
4-11
MPR302BE040
5700
MPR302BB040
5700
MPR303
8-22
MPR303BE080
5700
MPR303BB080
5700
MPR304
16-44
MPR304BE160
5700
MPR304BB160
5700
MPR305
32-88
MPR305BE320
5700
MPR305BB320
5700
L&T, ESP 01.11.2013
Bimetal Overload Relays
Type ML
Type MX-R0
ML
MX - R0
Type of
Mounting
(Operation)
(Directly
Operated)
Direct
Mounting on
MX Contactors
Relay Range
(A)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Type of
Mounting
(Operation)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
ML 1
0.1 - 0.16
ST94074OOBO
835
10
0.16 - 0.24
ST94074OODO
835
10
0.15 - 0.25
SS91858OODO
1565
10
0.22 - 0.33
ST94074OOEO
835
10
0.25 - 0.4
SS91858OOFO
1565
10
0.3 - 0.45
ST94074OOGO
835
10
0.4 - 0.65
SS91858OOHO
1565
10
0.45 - 0.67
ST94074OOHO
835
10
0.6 - 1
SS91858OOKO
1565
10
0.67 - 1.0
ST94074OOKO
835
10
1 - 1.6
SS91858OOMO
1565
10
1.0 - 1.5
ST94074OOMO
835
10
1.5 - 2.5
SS91858OOPO
1565
10
1.4 - 2.1
ST94074OONO
835
10
2.5 - 4
SS91858OORO
1565
10
1.8 - 2.7
ST94074OOPO
835
10
4 - 6.5
SS91858OOTO
1565
10
2.4 - 3.6
ST94074OOQO
835
10
6 - 10
SS91858OOVO
1565
10
3.5 - 5
ST94074OOSO
835
10
10 - 16
SS91858OOBO
1565
10
4.0 - 6.0
ST94074OOTO
835
10
5.5 - 8.5
ST94074OOUO
835
10
8.5 - 12.5
ST94074OOVO
835
10
(Directly
Operated)
Direct
Mounting on
ML 1.5 Contactors
ML 2 / ML 3
(Directly
Operated)
Direct
Mounting on
ML 2/3 Contactors
9 - 14
SS91859OOAO
2315
2
13 - 21
SS91859OOCO
2315
2
20 - 32
SS91859OOEO
2315
2
28 - 42
SS91859OOFO
2315
2
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Type MU
Type MK1
MK1
Type of
Mounting
(Operation)
Relay Range
(A)
MU1
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
0.6 - 1
SS90035OOKO
740
10
1 - 1.6
SS90035OOMO
740
10
1.5 - 2.5
SS90035OOPO
740
10
2.5 - 4
SS90035OORO
740
10
4 - 6.5
SS90035OOTO
740
10
6 - 10
SS90035OOVO
740
10
9 - 14
SS90035OOAO
740
10
11 - 18
SS90036OOCO
775
10
13 - 22
SS91888OODO
815
10
Relay Range
(A)
(Directly
Operated)
Direct
Mounting on
MK1 Contactors
L&T, ESP 01.11.2013
Type of
Mounting
(Operation)
MU2
Relay Range
(A)
Cat. No.
4 - 6.5
SS96557OOTO
990
1
6 - 10
SS96557OOVO
990
1
MU1
(Directly
Operated)
Direct
Mounting on
MU Contactor
MU2
9 - 14
SS95979OOAO
1080
1
13 - 21
SS95979OOCO
1150
1
20 - 32
SS95979OOEO
1395
1
28 - 42
SS95979OOFO
1650
1
11
Accessories for Bimetal Overload Relays
Accessories for Bimetal Overload Relays
Relay Mounting Kit
Din Rail Mounting Kit
MN2 Relay
Kit for Mounting MN5 Relay
Std.
Pkg.
(Nos.)
Description
Cat. No.
M.R.P.
(`)
Per Unit
Push button unit for MK 1 / ML Relays
SS90004
120
1
Push button extn. unit for MN 2 Relays
SS94968
35
100
Kit for Mounting MN 2 Relay on
ML 1.5 contactor
SS94701
130
50
Kit for Mounting MN 2 Relay
separately (Direct Mounting Type)
SS94700
130
50
Kit for Mounting MN 5 Relay on
MNX 95 / 110 / 140 contactor
SS94638
190
20
Kit for Mounting MN 5 Relay on
ML 2 / ML 3 contactor
SS94151
145
20
Kit for Mounting MN5 Relay on
ML 4 / ML 6 contactor
SS94152
185
20
DIN Rail Mounting Kit Relay on
MN 2 Relay
SS91887
100
50
Relay Reset Cord for MN2 Relay
400 mm
650 mm
900 mm
1200 mm
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
MN2 Relay reset cord - 400mm
SB94207OOOO
515
1
MN2 Relay reset cord - 650mm
SB94208OOOO
540
1
MN2 Relay reset cord - 900mm
SB94209OOOO
590
1
MN2 Relay reset cord - 1200mm
SB94210OOOO
665
1
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
CS96335OOOO
190
1
Separate Mounting Kit
for RTO Relay
Description
RTO Relay Separate Mounting Kit
Timers
Electronic Timers
Type ET 100
Thermal Timers
Type GT 200
ET 100
GT 200
Cat. No.
M.R.P.
(`)
Per Unit
Std
Pkg.
(Nos.)
3 - 10 secs.
SE92001
3275
1
9 - 30 secs.
SE92002
3275
1
36 - 120 secs.
SE92003
3275
1
3 - 10 secs.
SE92005
3275
1
9 - 30 secs.
SE92006
3275
1
SE92007
3275
1
Description
110 / 240V, 50Hz for
Description
Operating Voltages:
230 / 250V, 360V, 400 / 440V, 500V,
50 Hz for 5 - 18 secs. range
Cat. No.
M.R.P.
(`)
Per Unit
Std
Pkg.
(Nos.)
SS91270
2480
1
240 / 360 / 415V#, 50Hz for
36 - 120 secs.
Notes: 1) Available till stocks last
2) # 360V tap can be used for 240V connections
3) Ordering Suffix is OOOO
New
Electronic Timers
Type ST 100
Suffix
250V
NOOO
320V
ROOO
360V
COOO
380V
LOOO
400 / 440V
POOO
ST 100
Cat. No.
M.R.P.
(`)
Per Unit
Std
Pkg.
(Nos.)
3 - 30 secs.
ST80328OOOO
1440
1
12 - 120 secs.
ST80329OOOO
1440
1
Description
Ordering Suffix for GT 200 Timer
Voltage (V)
240 / 360 / 415V, 50Hz for
Note: ST 100 supplied with Mounting Kit, suitable for ET 100 replacement.
For Complete range of Timing Devices, please refer the Panel Accessories Price List
12
L&T, ESP 01.11.2013
Control Accessories
Actuator Units Type TK3
Push Button Pendants
6A, 415V, 50 Hz (Suitable for 30.5mm Cutout Dia.)
6A, 415V, 50 Hz
Cat. No.
M.R.P.
(`)
Per Unit
Std
Pkg.
(Nos.)
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std
Pkg.
(Nos.)
Selector actuator - 2 position
(black only)
SS91516
440
30
With 2 push buttons
SS90502
1025
30
With 4 push buttons
SS90504
1905
30
Selector actuator - 3 position
(black only)
SS91517
440
30
With 6 push buttons
SS90506
2560
30
Mushroom push button actuator
(red, green or black)
SS91518
270
30
Shrouded push button actuator
(red, black, green, yellow, blue
or grey)
SS91519
195
30
Unshrouded push button actuator
(red, black, green, yellow, blue
or grey)
SS91520
195
30
Key actuator - lockable in 1 position
SS91522 *
600
30
Key actuator - lockable in both
positions
SS91521 *
600
30
Element with 2 fixing screws
SS90375 *
220
100
Description
Ordering Suffix is OOOO
New
Single Phase Preventor Relay
Sz5
SDz5
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SDz5, SPPR + Timer, 360V
XM81808OOOO
1845
1
SDz5, SPPR + Timer, 415V
XM81809OOOO
1845
1
Single Phase Preventor Relay - Sz5
380V AC (6 wires)
CS94824LOOO
630
1
Single Phase Preventor
Relay - Sz5 380V AC (7 wires)
ST92166OOOO
630
1
Description
Ordering Suffix for Colour
Black
OAOO
Red
OBOO
Green
OCOO
Yellow
ODOO
Blue
OEOO
Grey
OFOO
*
OOOO
TM
To order Control Accessories, please specify
Type, Cat no. & Ordering Suffix for color
For Timing, Control Devices and Supply Monitors from GIC and 22.5 mm dia Range of Modular Remote Control & Indicating Units from ESBEE,
please refer Panel Accessories Price List.
L&T, ESP 01.11.2013
11
3
Motor Protection Circuit Breakers
Features
l
l
l
l
l
l
With compactness MPCB provides high-performance short-circuit current breaking
Wide range of current adjustment dial for optimum protection
Stand-alone motor protection
With Single phasing protection
All accessories are common for both frames and separate short circuit alarm is also available
Padlocking features available on MPCB rotary knob and rocker type
Procedure for selecting the appropriate model:
Confirm the motor full load current
/
Three-phase load
Single-phase load
For applications in a single-phase
circuit, connect the 3-poles in series
Select the rated current of MPCB
Select the branch circuit cable & confirm the control panel specifications
Confirm the short-circuit current of the circuit
Select the operating characteristics
Long-time operating type or quick
operating type thermal overload relay desired
Same characteristics as desired
for a standard thermal overload relay
Instantaneous trip type MPCB
MOG-H1M, MOG-H2M
Adjustable thermal magnetic trip type MPCB
MOG-S1, MOH-H1, MOG-H2
Note: Please contact the nearest branch office for fuseless type 2 co-ordination selection chart.
Type MOG-S1 (Rocker Type)
Type MOG-H1M (Rotary Type) - Frame 1
(ROM cannot be fitted with MOG - S1)
With short circuit & overload protection
With short circuit protection only
Rating
(A)
Recommended
Motor Rating
at 415V, 3-Ph,
50Hz (KW)
Thermal
Release
range
(A)
Cat. No.
Std.
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
Rating
(A)
Recommended
Short Circuit
Motor Rating
Release
at 415V, 3-Ph,
(A)
50Hz (KW)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
0.16
-
0.1 - 0.16
ST41889OOOO
2340
1
0.16
-
2.1
ST41923OOOO
2190
1
0.25
0.06
0.16 - 0.25
ST41890OOOO
2340
1
0.25
0.06
3.3
ST41924OOOO
2190
1
0.40
0.09
0.25 - 0.40
ST41891OOOO
2340
1
0.40
0.09
5.2
ST41925OOOO
2190
1
1
0.63
0.12
8.2
ST41926OOOO
2940
1
1
1.00
0.25
13
ST41927OOOO
2940
1
1
1.60
0.55
20.8
ST41928OOOO
2940
1
0.75
32.5
ST41929OOOO
2940
1
0.63
1.00
1.60
0.12
0.25
0.55
0.40 - 0.63
0.63 - 1.00
1.00 - 1.60
ST41892OOOO
ST41893OOOO
ST41894OOOO
2445
2445
2505
2.50
0.75
1.60 - 2.50
ST41895OOOO
2505
1
2.50
4.00
1.50
2.50 - 4.00
ST41896OOOO
2570
1
4.00
1.50
52
ST41930OOOO
3100
1
6.30
2.20
4.00 - 6.30
ST41897OOOO
2585
1
6.30
2.20
81.9
ST41931OOOO
3100
1
10.00
4.00
6.30 - 10.00
ST41898OOOO
2585
1
10.00
4.00
130
ST41932OOOO
3205
1
13.00
5.40
9.00 - 13.00
ST41899OOOO
2855
1
13.00
5.40
169
ST41933OOOO
3330
1
16.00
7.50
208
ST41934OOOO
3385
1
20.00
9.00
260
ST41935OOOO
3625
1
25.00
12.50
325
ST41936OOOO
4385
1
32.00
15.00
416
ST41937OOOO
6015
1
Breaking capacity: Icu = 100kA upto 10A & Icu = 50kA for 13A
Breaking capacity: Icu = 100kA upto 13A & Icu = 50kA from 16A - 32A
14
L&T, ESP 01.11.2013
Motor Protection Circuit Breakers
Type MOG-H1 (Rotary Type) - Frame1
Type MOG-H2 (Rotary Type) - Frame 2
With short circuit & overload protection
Rating
(A)
Recommended
Motor Rating
at 415V, 3-Ph,
50Hz (KW)
With short circuit & overload protection
Thermal
Release
range
(A)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Rating
(A)
Thermal
Release
range
(A)
Recommended
Motor Rating
at 415V, 3-Ph,
50Hz (KW)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
0.16
-
0.1 - 0.16
ST41904OOOO
2750
1
32.00
15.00
24.00 - 32.00 ST41919OOOO
9470
1
0.25
0.06
0.16 - 0.25
ST41905OOOO
2885
1
40.00
20.00
28.00 - 40.00 ST41920OOOO
9590
1
0.40
0.09
0.25 - 0.40
ST41906OOOO
2885
1
50.00
25.00
35.00 - 50.00 ST41921OOOO
10540
1
0.63
0.12
0.40 - 0.63
ST41907OOOO
3105
1
63.00
34.00
45.00 - 63.00 ST41922OOOO
11220
1
1.00
0.25
0.63 - 1.00
ST41908OOOO
3105
1
1.60
0.55
1.00 - 1.60
ST41909OOOO
3110
1
2.50
0.75
1.60 - 2.50
ST41910OOOO
3110
1
4.00
1.50
2.50 - 4.00
ST41911OOOO
3170
1
6.30
2.20
4.00 - 6.30
ST41912OOOO
3230
1
10.00
4.00
6.30 - 10.00
ST41913OOOO
3330
1
13.00
5.40
9.00 - 13.00
ST41914OOOO
3620
1
16.00
7.50
11.00 - 16.00 ST41915OOOO
4000
1
20.00
9.00
14.00 - 20.00 ST41916OOOO
4315
1
25.00
12.50
19.00 - 25.00 ST41917OOOO
4695
1
32.00
15.00
24.00 - 32.00 ST41918OOOO
7325
1
Breaking capacity: Icu = 100kA upto 13A & Icu = 50kA from 16A - 32A
Breaking capacity: Icu = 50kA from 32A - 63A
Type MOG-H2M (Rotary Type) - Frame 2
With short circuit protection only
Rating
(A)
Recommended
Motor Rating Short Circuit
Release
at 415V, 3-Ph,
(A)
50Hz (KW)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
32.00
15.00
416
ST41938OOOO
7730
1
40.00
20.00
520
ST41939OOOO
7730
1
50.00
25.00
650
ST41940OOOO
9430
1
63.00
34.00
819
ST41941OOOO
9430
1
Breaking capacity: Icu = 50kA from 32A - 63A
Accessories for MOG
Short Circuit
Alarm
Auxiliary + Alarm
External
Operating Handle
Description
Cat. No.
Connecting
Busbar link
Shunt Trip
M.R.P. Std.
Pkg.
(`)
Per Unit (Nos.)
3 Phase Feed
in terminal
Description
Busbar Safety
Cover
Cat. No.
M.R.P. Std.
Pkg.
(`)
Per Unit (Nos.)
Connecting Busbar link
Auxiliary Contact Front mtg. 1NO
ST41942OOOO
480
10
2 MPCB 45 mm width w/o acc
ST41957OOOO
590
5
Auxiliary Contact Front mtg. 1NC
ST41943OOOO
480
10
3 MPCB 45 mm width w/o acc
ST41958OOOO
650
5
Auxiliary Contact Left side mtg. 2NO
ST41944OOOO
590
1
4 MPCB 45 mm width w/o acc
ST41959OOOO
705
5
Auxiliary Contact Left side mtg. 1NO + 1NC
ST41945OOOO
590
1
5 MPCB 45 mm width w/o acc
ST41960OOOO
765
5
Auxiliary Contact Left side mtg. 2NC
ST41946OOOO
575
1
2 MPCB 45 mm width with one acc 9 mm
ST41961OOOO
690
5
Trip Alarm Contact Front mtg. 1NO
ST41947OOOO
765
10
3 MPCB 45 mm width with one acc 9 mm
ST41962OOOO
750
5
Trip Alarm Contact Front mtg. 1NC
ST41948OOOO
765
10
4 MPCB 45 mm width with one acc 9 mm
ST41963OOOO
805
5
Auxiliary + Alarm Left side mtg. 2NO
ST41949OOOO
815
1
5 MPCB 45 mm width with one acc 9 mm
ST41964OOOO
865
5
Short circuit alarm Left side mtg. 1NO + 1NC ST41950OOOO
815
1
2 MPCB 55 mm width w/o acc
ST41966OOOO
1080
1
Shunt trip 24V DC
ST41951OOOO
1330
1
3 MPCB 55 mm width w/o acc
ST41967OOOO
1230
1
Shunt trip 110V, 50Hz
ST41952OOOO
1400
1
4 MPCB 55 mm width w/o acc
ST41968OOOO
1480
1
Shunt trip 230V, 50Hz
ST42952OOOO
1400
1
2 MPCB 55 mm width with one acc 9 mm
ST41969OOOO
1180
1
Under Voltage release, 110V, 50Hz
ST41953OOOO
1400
1
3 MPCB 55 mm width with one acc 9 mm
ST41970OOOO
1330
1
Under Voltage release, 415V, 50Hz
ST41954OOOO
1400
1
4 MPCB 55 mm width with one acc 9 mm
ST41971OOOO
1580
1
External operating handle, (Black) Frame 1
ST41955OOOO
1050
1
2 MPCB 55 mm width with two acc 18 mm
ST41972OOOO
1380
1
External operating handle, (Black) Frame 2
ST41956OOOO
1050
1
4 MPCB 55 mm width with two acc 18 mm
ST41973OOOO
1530
1
Feed in terminal for 45 mm width Busbar
ST41965OOOO
690
1
Feed in terminal for 55 mm width Busbar
ST41974OOOO
1195
1
Bus bar safety cover 45 mm width Busbar
ST41975OOOO
300
10
Bus bar safety cover 55 mm width Busbar
ST41976OOOO
325
10
L&T, ESP 01.11.2013
15
Motor Starters
Direct-on-Line Starters
Direct-on-Line Starters
in Sheet-Steel Enclosure Type MF, MK, MU & MB
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
MF1 3-Ph
Max. Motor
Output at
415V, 3-Ph
HP
kW
Relay
Max.
Range
(A)
7.5
5.5
7.5
5.5
7.5
MK1
in Sheet-Steel Enclosure Type MN with Single Phase Protection
feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
MB1
MN 16
Max. Motor
Output at
415V, 3-Ph
HP
kW
MN 45
Relay
Max.
Range
(A)
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SS97210
1100
1
10.0
7.5
9 - 15
MN 16 DOL
SS94351
2900
1
SS96210
1810
1
15.0
11.0
14 - 23
MN 25 DOL
SS94352
4435
1
MK1 DOL
SS96211
1850
1
20.0
15.0
20 - 33
MN 32 DOL
SS94353
7150
1
13 - 22
MK1 DOL
SS96228
1895
1
30.0
22.5
30 - 50
MN 45 DOL
SS94017
12235
1
7.5
13 - 21
MU1 DOL #
SS95647
3070
1
45.0
33.5
45 - 75
MN 65 DOL
SS94018
16755
1
Description
Cat. No.
9 - 15
MF1
9 - 14
MK1 DOL
5.5
11 - 18
7.5
5.5
10.0
10.0
7.5
14 - 23
MB1 DOL #
SS95649
3090
1
15.0.
11.0
20 - 32
MU2 DOL #
SS95648
4130
1
15.0
11.0
20 - 33
MB2 DOL #
SS95650
4150
1
For lower relay ranges, please refer Agricultural Electrical Products' price list.
in Sheet-Steel Enclosure Type ML
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
Single Phase Starters
MH0
Max. Motor
Output at
230V, 1-Ph
Direct-on-Line Starters
ML 3
MF1 1-Ph
HP
kW
Relay
Max.
Range
(A)
0.5
0.37
4 - 6.5
MH0 (Coil operated) ST37491BOTO
950
1
15.0
11.0
1.0
0.75
6 - 10
MH0 (Coil operated) ST37491BOVO
950
1
20.0
15.0
20 - 32
ML 2 DOL
SS90702
7495
1
2.0
1.5
10.5 - 17.5
MF1
SS97227OOBO
820
1
30.0
22.5
28 - 42
ML 3 DOL
SS90722
12750
1
3.0
2.2
12 - 20
MF1
SS97227OOCO
820
1
Description
Std.
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
Cat. No.
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
20 - 32
ML 1.5 DOL
SS91854
4500
1
in Sheet-Steel Enclosure Type ML
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
in Sheet-Steel Enclosure Type MK, MU & MB
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
MU 1S
Relay
Max.
Range
(A)
Semi-Automatic Star-Delta Starters
Semi-Automatic Star-Delta Starters
MK 1S
Max. Motor
Output at
415V, 3-Ph
HP
kW
MB 2S
ML 2S
Max. Motor
Output at
415V, 3-Ph
HP
kW
Relay
Max.
Range
(A)
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1
25.0
18.5
13 - 21
ML1.5 SASD
SS91856
10355
1
5965
1
35.0
26.0
20 - 32
ML2 SASD
SS90707
18100
1
5985
1
SS95891
7935
1
SS95895
8905
1
MU2 SASD #
SS95893
10030
1
MB2 SASD #
SS95897
10540
1
Max. Motor
Output at
415V, 3-Ph
HP
kW
Relay
Max.
Range
(A)
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
12.5
9.3
9 - 14
MK1 SASD
SS96255
5940
15.0
11.0
11 - 18
MK1 SASD
SS96258
15.0
11.0
13 - 22
MK1 SASD
SS96260
15.0
11.0
13 - 21
MU1 SASD #
15.0
11.0
14 - 23
MB1 SASD #
30.0
22.5
20 - 32
30.0
22.5
20 - 33
For lower relay ranges, please refer Agricultural Electrical Products' price list.
Note: 1) # Type MU1 / MU2 consists of type MU Relay + MU1 / MU2 contactors
Type MB1 / MB2 consists of type MN Relay + MU1 / MU2 contactors
2) For Ordering Suffix please refer table C page No. 19
L&T, ESP 01.11.2013
17
Motor Starters
Spares for MK1 Starters
Fully Automatic Star-Delta Starters
in Sheet-Steel Enclosure Type MN
with Single Phase Protection feature
(Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph)
Aux contact
block
MN 16F
Max. Motor
Output at
415V, 3-Ph
Spare
coil
Push
button unit
Combination
coil
HP
kW
Relay
Max.
Range
(A)
15.0
11.0
9 - 15
MN 16 FASD
SS94362
9765
1
25.0
18.5
14 - 23
MN 25 FASD
SS94364
10920
1
400 / 440V, 50Hz
SS90047
200
10
35.0
26.0
20 - 33
MN 32 FASD
SS94366
17965
1
360V, 50Hz
SS90165
200
10
1
320V, 50Hz
SS90166
200
10
230V, 50Hz
SS90045
200
10
220V, 50Hz
SS90044
200
10
110V, 50Hz
SS90043
200
10
Auxiliary contact block: 1 NO + 1 NC
SS90120
275
50
Spare kit without coil
SS90983
450
50
Thermal timer without combination coil
SS90224
780
1
Combination coils for 400 / 440V, 50Hz
SS90443
510
10
Combination coils for 230V, 50Hz
SS90444
510
10
Combination coils for 380V, 50Hz
SS90445
510
10
Combination coils for 360V, 50Hz
SS90446
510
10
Push Button Unit
SS90004
120
1
Arc Shield
SS50004
130
1
Contact bridge without Contacts
SS50005
120
1
50.0
37.5
30 - 50
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
MN 45 FASD
SS94021
28850
75.0
55.0
45 - 75
MN 65 FASD
SS94022
47815
1
90.0
67.0
45 - 75
MN 80 FASD
SS94705
52270
1
125.0 90.0
66 - 110
MN 110 FASD
SS94706
68410
1
175.0 130.0
90 - 150
MN 140 FASD
SS94707
71615
1
Description
Single Moving Contact
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SS91009
40
10
Std. Operating coils
Combination coils
Fully-Automatic Star-Delta Starters
in Sheet-Steel Enclosure Type MK, ML, MU & MB
(Motor Rating AC-3 Duty, 415V, 50Hz, 3Ph)
MK 1F
MB 1F
Spares for MN Starters
MU 2F
Max. Motor
Output at
415V, 3-Ph
HP
kW
Relay
Max.
Range
(A)
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
12.5
9.3
9 - 14
MK1 FASD
SS96254
6745
1
15.0
11.0
11 - 18
MK1 FASD
SS96257
6805
1
15.0
11.0
13 - 22
MK1 FASD
SS96259
6830
1
15.0
11.0
13 - 21
MU1 FASD #
SS95890
9190
1
15.0
11.0
14 - 23
MB1 FASD #
SS95894
9230
1
30.0
22.5
20 - 32
MU2 FASD #
SS95892
11070
1
30.0
22.5
20 - 33
MB2 FASD #
SS95896
11170
1
For lower relay ranges, please refer Agricultural Electrical Products' price list.
ML 2F
Relay
Max.
Range
(A)
Description
Cat. No.
25.0
18.5
13 - 21
ML1.5 FASD
35.0
26.0
20 - 32
ML2 FASD
50.0
37.5
28 - 42
75.0
55.0
45 - 75
125.0 90.0
66 - 110
Bracket for Mounting cont. MNX 25 - 32
Cat. No.
SS94030OOOO
M.R.P. Std.
Pkg.
(`)
Per Unit (Nos.)
100
20
Salient Features and Benefits of Starters
ML 1.5F
Max. Motor
Output at
415V, 3-Ph
HP
kW
Description
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SS91855
11755
1
SS90705
18660
1
ML3 FASD
SS90730
30745
1
ML4 FASD
SS90913
52680
1
ML6 FASD
SS90923
86370
1
250.0 180.0 135 - 225
ML10 FASD
SS90938
136710
1
400.0 300.0 180 - 300
ML12 FASD
SS91019
154850
1
l
Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
l
Sheet steel enclosures with IP 54 protection
l
Wide range of relay settings and coil voltages
l
Standardized accessories and spares available
Note: 1) # Type MU1 / MU2 consists of type MU Relay + MU1 / MU2 contactors
Type MB1 / MB2 consists of type MN Relay + MU1 / MU2 contactors
2) For Ordering Suffix please refer table C page No. 19
18
L&T, ESP 01.11.2013
Submersible Pump Controllers
Submersible Pump Controller
Submersible Pump Controller
In Sheet Enclosure Type MU - G
(Motor Rating AC-3 Duty, 415V, 50Hz, 3 phase)
MU - G6
Max. Motor
Output at
415V, 3-Ph
HP
kW
Relay
Max.
Range
(A)
In Sheet Enclosure Type MU-G
(Motor Rating AC-3 Duty, 415V, 50 Hz, 3 phase)
MU - G10
MU-G20
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
6
4.5
9 - 14 MU - G6 DOL Starter *
SS97756
5000
1
10
7.5
13 - 21 MU - G10 DOL Starter *
SS95983
5940
1
10
7.5
28 - 42 MU - G10H DOL Starter * SS95974
6920
1
Max. Motor
Output at
415V, 3-Ph
HP
kW
MR-G2
Max. Motor
Output at
230V, 3-Ph
HP
kW
Relay
Max.
Range
(A)
0.5
0.37
6 - 10
1.0
0.75
9 - 14
1.5
1.1
11 - 18
2.0
1.5
13 - 22
Type MR-G2 *
For Single
Phase Motors
1
20
15
13 - 21
MU-G20 Fully Automatic
SS95984
Star - Delta Starter*
11450
1
20
15
28 - 42
MU-G20 Fully Automatic
SS95975
Star - Delta Starter*
14100
1
30
22.5
30 - 50
MU-G30 Fully Automatic
CS96008
Star - Delta Starter*
22850
1
50
37.5
45 - 75
MU-G50 Fully Automatic
CS96009
Star - Delta Starter*
36160
1
75
101 66 - 110
MU-G75 Fully Automatic
CS96451
Star - Delta Starter*
49000
1
M-POWER - Module for
Mobile Starter
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SS96988
3360
1
SS96560
3670
1
SS96989
4055
1
SS96990
4245
1
13 - 22
SS97725
4540
1
6.5 - 11
SS97734
2255
1
SS97736
2350
1
SS97737
2435
1
l
SS97738
2480
1
l
12 - 20
1.1
12 - 20
2.0
1.5
12 - 20
For Single
Phase Motors
New
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Module for Mobile Starter &
Submersible Controllers
GSM0301OOOO
5950
1
Salient Features and Benefits of
Submersible Pump Controller
2.2
0.75
Std.
Pkg.
(Nos.)
9700
0.37
1.5
M.R.P.
(`)
Per Unit
MU-G15 Fully Automatic
CS94091
Star - Delta Starter*
0.5
1.0
Cat. No.
9 - 14
3.0
Type MF-G1 *
Description
* For lower relay ranges, please refer Agricultural Electrical Products' price list.
MF-G1
Description
MU-G75
11
New
In Sheet Steel Enclosure Type MR-G, MF-G
MU-G50
New 15
* For lower relay ranges, please refer Agricultural Electrical Products' price list.
Submersible Pump Controller
Relay
Max.
Range
(A)
l
l
Note: For dual meter (Ammeter + Voltmeter) version - Add (`) 210
l
* Also available with lower Relay Ranges
l
Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1
Protections Offered - Overload, Single Phasing,
Phase reversal, Phase imbalance
Auto Restart Feature
Vibration proof enclosure with IP54 protection class
Indications Offered - ON/OFF, Voltage and Ampere
Compatible with M-POWER
Ordering Suffix for MK1/MU/MB/ML & MN Starters
Table C
Realay Range (A)
Coil Voltages
B - 240 V
C - 360 V
D - 415 V
P - 440 V
MK1
A : 9 - 14
MU
A : 9 - 14
MB
B : 9 - 15
ML
A : 9 - 14
MN
B : 9 - 15
C : 11 - 18
C : 13 - 21
D : 14 - 23
B : 10 - 16
D : 14 - 23
D : 13 - 22
E : 20 - 32
E : 20 - 33
C : 13 - 21
E : 20 - 33
M : 1 - 1.6
E : 20 - 32
G : 30 - 50
P : 1.5 - 2.5
F : 28 - 42
J : 45 - 75
R : 2.5 - 4
G : 30 - 50
K : 66 - 110
T : 4 - 6.5
J : 45 - 75
Q : 2 - 3.3
V : 6 - 10
K : 66 - 110
S:3-5
M : 90 - 150
U : 4.5 - 7.5
P : 135 - 225
V : 6 - 10
Q : 180 - 310
R : 2.5 - 4
T : 13 - 21
L&T, ESP 01.11.2013
19
Digital Soft Starters
EMX3 Soft Starters
Ordering Information for EMX3 Soft Starter
EMX3 Cat. No.
Suitable for Motor with
#
Rated Current in Amps
6 Wire
3 Wire
(Inside Delta
(Inline
Connection)
Connection)
E
M.R.P.
(`)
Per Unit
EMX3-0023B-411
23
34
68200
EMX3-0043B-411
43
64
73200
EMX3-0053B-411
53
79
85400
EMX3-0076B-411
76
114
91400
EMX3-0097B-411
97
145
100000
EMX3-0105B-411
105
157
116000
EMX3-0145B-411
145
217
134000
EMX3-0170B-411
170
255
152000
EMX3-0220B-411
220
330
168000
EMX3-0255C-411
255
382
177000
EMX3-0360C-411
360
540
188000
EMX3-0430C-411
400
645
285000
EMX3-0620C-411
620
930
293000
EMX3-0650C-411
650
975
310000
EMX3-0790C-411
790
1185
378000
EMX3-0930C-411
930
1395
475000
EMX3-1200C-411
1200
1800
732000
EMX3-1410C-411
1410
2115
878000
EMX3-1600C-411
1600
2400
970000
EMX3 Cat. No.
M.R.P.
(`)
Per Unit
EMX3-0255B-411
255
382
245000
EMX3-0350B-411
350
525
298000
EMX3-0425B-411
425
638
352000
EMX3-0500B-411
500
750
380000
EMX3-0580B-411
580
870
443000
EMX3-0700B-411
700
1050
499000
EMX3-0820B-411
820
1230
562000
EMX3-0920B-411
920
1380
658000
EMX3-1000B-411
1000
1500
719000
X
3
Keypad
1 = with keypad
Control voltage
1 = 110-210 VAC & 220-440 VAC
Mains voltage
4 = 200 ~ 440 VAC
Bypass
B = Internally Bypassed
C = Non-Bypassed
(External contactor required)
Built - In
Nominal current rating
0023 - 23A
.
.
1600 - 1600A
Terminals for
connecting External
contactor (AC1 duty)
* All protections
remain active
during bypass
operation
New
Suitable for Motor with
#
Rated Current in Amps
6 Wire
3 Wire
(Inside Delta
(Inline
Connection)
Connection)
M
Bypass
Contactor
Bypass
Contactor
Built - In
# Note : The above EMX3 current ratings are based on 300% starting current,
10 starts per hour, 10 seconds starting time and ambient temperature of 45°C.
For proper sizing of soft starter based on the application parameters please use
Winstart Software.
For Winstart software please contact Customer Interaction Centre.
EMX3 Soft Starters : For Heavy Duty Applications
• Ratings from 23 to 1600A
• Control Voltage from 94VAC to 484VAC
• Constant current
• XLR-8 Adaptive acceleration control for pumps
• Kickstart
• XLR-8 Adaptive deceleration control for pumps
• Forward / Reverse Jog
• Comprehensive motor protection
• Large LCD Keypad
• Auto Start / stop
• 2 motor data sets
• Fully programmable overload trip
• 5 digital inputs, 4 digital outputs,
1 analog output
• Built-in RTD & Thermistor inputs
• 99 event logs with time stamping
• Starter communication timeout
• Network communication trip
• Auto detection of inline or inside
delta power connection
• Programmable auto start/stop
• 24 VDC auxiliary power supply
• Power through operation allows to run soft
starter even with one SCR shorted
• Emergency run operation
• I/O expansion card (optional)
We recommend the use of :
1. Line Contactor : This will isolate and protect the soft starter SCR's
from any voltage transient while it's not in operation.
2. Bypass Contactor (For models without built-in bypass) : This will
bypass and protect the soft starter SCR's while in running state from
Current and Voltage transient's.
3. Semiconductor fuses : This will protect the starter SCR's during
starting and stopping states from current transient's and excess I²T.
20
L&T, ESP 01.11.2013
Digital Soft Starters
CSX Soft Starters
CSXi Soft Starters
Ordering Information for CSX Series Soft Starter
M.R.P.
(`)
Per Unit
Motor
kW
Cat. No.
CSX-007-41
28600
7.5
CSXi-007-41
41500
CSX-015-41
30300
15
CSXi-015-41
48100
18
CSX-018-41
31400
18
CSXi-018-41
50500
22
CSX-022-41
37100
22
CSXi-022-41
53900
30
CSX-030-41
41800
30
CSXi-030-41
60000
37
CSX-037-41
47900
37
CSXi-037-41
65700
45
CSX-045-41
54500
45
CSXi-045-41
79200
55
CSX-055-41
59400
55
CSXi-055-41
86700
75
CSX-075-41
80900
75
CSXi-075-41
101000
90
CSX-090-41
88000
90
CSXi-090-41
127000
110
CSX-110-41
97000
110
CSXi-110-41
141000
Motor
kW
Cat. No.
7.5
15
M.R.P.
(`)
Per Unit
C
S
X
Control Voltage
1 = 110 VAC & 220-440 VAC
Mains voltage
4 = 200 ~ 440 VAC
Normal kW rating @ 400VAC
007 – 7.5 kW
.
.
110 – 110 kW
Motor protection
Blank (no space) - Without
motor protection
i - With motor protection
Note : The above CSX & CSXi ratings are based on 400% starting current,
10 starts per hour up to 30kW & 6 starts per hour for 37kW & above, 6 seconds
starting time and ambient temperature of 45°C.
For proper sizing of soft starter based on the application parameters please use
Winstart Software.
CSX Soft Starters : For Standard Applications
Optional Modules/Cards for CSX / CSXi / EMX3
•
•
•
•
•
•
Inbuilt Bypass Contactor
Soft Start / Soft Stop
Compact
Complements existing motor protection
Truly plug & play
Communication options available
CSXi Soft Starters : For standard applications
Cat. No.
M.R.P.
(`)
Per Unit
Modbus Interface
PIM-MB-01
13000
Profibus Interface
PIM-PB-01
21000
DeviceNet Interface
PIM-DN-01
17000
Description
PIM-USB-01
8000
PIM-MT-01
40000
Ethernet IP Module
PIM-EI-01
44000
Profinet Module
PIM-PN-01
44000
EMX3 RTD/Ground Fault Expansion Card
995-04804-00
17000
EMX3 I/O Expansion Card
995-04803-00
10000
USB Interface
Modbus TCP Module
• Inbuilt Bypass Contactor
• Soft start / Soft stop / Adjustable current limit
• Essential motor protections against
• Overload
• Single phasing
• Instantaneous overcurrent
• Phase sequence reversal
• Abnormality in supply
• Unbalanced current
• Thermistor protection through PTC
• Excess start time setting
• Communication options available
• PC Interface as optional
We recommend the use of :
1. Line Contactor : This will isolate and protect the soft starter SCR's
from any voltage transient while it's not in operation.
2. Bypass Contactor (For models without built-in bypass) : This will
bypass and protect the soft starter SCR's while in running state from
Current and Voltage transient's.
3. Semiconductor fuses : This will protect the starter SCR's during
starting and stopping states from current transient's and excess I²T.
L&T, ESP 01.11.2013
21
Switch-Disconnector-Fuse Units
Type FN S-D-F suitable for DIN fuse-link
Type FN S-D-F suitable for BS fuse-link
Features offered by FN S-D-F
l Range 32A to 800A, 415V, AC 23A
l 2P / TP / TPN Versions
l Suitable for cylindrical / DIN / Bolted fuse-link
l Available in interior / Sheet steel enclosure version
l Conforms to IEC 60947-3, IS/IEC 60947-3
l Door interlock & padlock facility
For Capacitor &
Motor back-up
FN TP S-D-F
Type FN (2P) S-D-F suitable for
New
DIN fuse-link
Rated
Current
(A)
FN TPN S-D-F
Type FN (TP) S-D-F suitable for
DIN fuse-link
Type FN (TPN) S-D-F suitable for
bolted fuse-link
Open Execution
Open Execution
Open Execution
Std.
Pkg
(Nos.)
Type
Suitable
fuse-link type
Cat. No.
M.R.P.
(`)
Per Unit
Type
Cat. No.
M.R.P.
(`)
Per Unit
Type
Suitable
fuse-link type
Cat. No.
M.R.P.
(`)
Per Unit
32
FN 32 2P
HF
SK95594
1315
FN 32 TP
ST27892
1490
FN 32 TPN
A1L
SK95653
1595
1
63
FN 63 2P
HF
SK95595
1765
FN 63 TP
ST27893
2095
FN 63 TPN
A1L
SK95651
2195
1
100
FN 100 2P HN Size 000/00
ST35086
3750
FN 100 TP
ST30287
4235
FN 100 TPN
A4
SK95570
4470
1
125
FN 125 2P HN Size 000/00
ST35087
4515
FN 125 TP
ST27894
5335
FN 125 TPN
A4
SK95009
5575
1
160
FN 160 2P HN Size 000/00
ST35088
4920
FN 160 TP
SK95998
5990
FN 160 TPN
A4
SK95714
5970
1
200
FN 200 2P
HN Size 0
ST35089
6255
FN 200 TP
ST27895
7875
FN 200 TPN
B2
SK95588
7370
1
250
FN 250 2P
HN Size 1
ST31674
7380
FN 250 TP
ST31731
9625
FN 250 TPN
B2 / B3
SK95682
9560
1
315
FN 315 2P
HN Size 1
ST38930
9335
FN 315 TP
ST27897
11910
FN 315 TPN
B3
SK95590
12415
1
400
FN 400 2P
HN Size 2
ST31676
11245
FN 400 TP
ST27898
14340
FN 400 TPN
B4
SK95591
13855
1
630
FN 630 2P
HN Size 3
ST35090
17895
FN 630 TP
ST27899
23110
FN 630 TPN
C2
SK95592
23305
1
800
FN 800 TP
HN Size 3
-
-
FN 800 TP
ST27900
25070
-
-
-
-
1
Note: Please refer page no. 25 for Switch-Disconnector & 4 pole Switch-Disconnector-Fuse
Type FN S-D-F suitable for DIN fuse-link (TPN)
FN - TPN (Open Execution)
Rated
Current
(A)
Suitable HRC fuse-link
Type
Range
(A)
FN in SS Enclosure
In Sheet Steel Enclosure
Open Execution
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
FN 32 TPN / FP CE*
SK95612*
3590
1
FN 63 TPN / FP CE*
SK95613*
4295
1
32
HF
2 to 32
FN 32 TPN / FP
SK95518
1605
1
32
HF
2 to 32
FN 32 TPN / FP CE*
SK95703*
1440
1
63
HF
2 to 63
FN 63 TPN / FP
SK95421
2205
1
63
HF
2 to 63
FN 63 TPN / FP CE*
SK95704*
1950
1
100
HN Size 000/00
63 to 100
FN 100 TPN
SK95568
4545
1
FN 100 TPN
SK95569
7080
1
125
HN Size 000/00
63 to 125
FN 125 TPN
SK95001
5970
1
FN 125 TPN
SK95005
8380
1
160
HN Size 000/00
63 to 160
FN 160 TPN
SK95713
6540
1
FN 160 TPN
SK95715
8985
1
200
HN Size 0
80 to 200
FN 200 TPN
SK95418
8315
1
FN 200 TPN
SK95511
11805
1
250
HN Size 1
125 to 250
FN 250 TPN
SK95642
9960
1
FN 250 TPN
SK95681
13625
1
315
HN Size 1
125 to 315
FN 315 TPN
SK95461
12430
1
FN 315 TPN
SK95514
16155
1
400
HN Size 2
200 to 400
FN 400 TPN
SK95481
14835
1
FN 400 TPN
SK95515
18850
1
630
HN Size 3
315 to 630
FN 630 TPN
SK95521
23980
1
FN 630 TPN
SK95547
30210
1
800
HN Size 3
315 to 800
FN 800 TPN
SK95679
26015
1
FN 800 TPN
SK95705
32730
1
* ‘CE’ handle has door interlock facility without defeat feature
Spare cat no. ST97895OOOO is of Interior FN 250 SDF suitable for Sheet steel enclosure
22
L&T, ESP 01.11.2013
HRC Fuses
Features offered by HRC fuse link
l Conforms to IEC 60269-2, IS 13703 part 2
l Range: 2A to 800A, 415V, AC 50Hz
l Type: Cylindrical (2A to 63A), DIN (63A to 800A) & Bolted (2A to 630A)
l High breaking capacity: 100kA for type HN and 80kA for type HF/HG/HQ
Cylindrical fuse links Type HF
Size
HF 2A
Rated
Current
(A)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
2
SF90144
87
30
4
SF90145
87
30
6
SF90146
87
30
SF90147
87
30
SF90148
87
30
SF90150
87
30
20
SF90151
87
30
25
SF90152
87
30
32
SF90142
87
30
40
SF90143
98
30
SF90158
215
30
SF90159
275
30
Suitable for Type FN 32 / 63 /
FNX 32 / 63 S-D-F
& for HCO 32 Fuse base
8
10
14 X 51
HF 63A
Description
16
Suitable for Type FN 63 / FNX 63 S-D-F
& for HC 63 Fuse base
50
63
DIN Type Fuse Links Type HN
Size
000
000
00
0
1
1
2
2
3
3
Description
63
80
100
125
Suitable for Type
FN 100/125/160 / FNX 100/125/160 S-D-F
Suitable for Type FA-C 100
& for HB 160 Fuse base
63
80
100
125
160
80
100
125
160
200
125
160
200
250
315
200
250
315
400
315
400
500
630
800
00
0
Rated
Current
(A)
Cat. No.
Suitable for Type
FN 100/125/160 / FNX 125/160 S-D-F
Suitable for Type FA-C 100
& for HB 160 Fuse base
Suitable for Type
FN 200 / FNX 200 S-D-F
& for HB 250 Fuse base
Suitable for Type
FN 250/315 / FNX 250/315 S-D-F
& for HB 250 Fuse base
Suitable for Type
FN 400 / FNX 400 S-D-F
& for HB 800 Fuse base
Suitable for Type
FN 630/800 / FNX 630/800 S-D-F
& for HB 800 Fuse base
SF94940
SF94941
SF94942
SF94946
SF94027
SF94028
SF94029
SF94030
SF94939
SF94128
SF94129
SF94130
SF94131
SF94132
SF94230
SF94231
SF94232
SF94233
SF94234
SF94332
SF94333
SF94334
SF94335
SF94434
SF94435
SF94436
SF94437
SF94938
Std.
Pkg.
(Nos.)
M.R.P.
(`)
Per Unit
285
305
305
350
370
370
370
385
405
505
505
505
515
515
535
555
555
615
750
760
790
805
815
1180
1180
1250
1320
1550
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1
1
1
Fuse holders & Fuse bases suitable for Cylindrical / DIN fuse-links
HB
HCO
L&T, ESP 01.11.2013
Rated
Current
(A)
Type
Description
32
HCO 32
63
HC 63
160
Std.
Pkg.
(Nos.)
SK91314
M.R.P.
(`)
Per Unit
163
SK91043
185
10
63-160
SK90405
290
12
HN-Size 0 & 1
80-250
SK90406
600
3
HN-Size 2 & 3
200-800
SK91051
1190
3
Suitable fuse-link
Type
Range (A)
Cat. No.
Fuse holder
HF
2-32
Fuse holder
HF
2-63
HB 160
Fuse base
HN-Size 000 & 00
250
HB 250
Fuse base
800
HB 800
Fuse base
10
23
HRC Fuses
Bolted fuse links: Type HG and HQ
Type
Fixing
Method
Size
F1
HG
A1
Offset,
staggered
F1
A1 L
A2
A1
A3
A1L
B1
Offset
A2
B2
HQ
A3
B3
A4
B1
B4
Centre Tag,
2 holes
B2
B3
C2
B4
Centre Tag,
4 holes
C2
C3
Rating
(A)
2
4
6
10
16
20
25
32
2
4
6
10
16
20
25
32
20
25
32
50
63
4
6
10
16
20
25
32
35
50
63
80
100
125
160
80
100
125
125
160
200
250
315
355
400
400
500
630
630
Description
Cat. No.
Suitable for type
HD 20H/20P/20B,
HD 32H/32P/32B fuse base
Suitable for type FN 32/63 S-D-F
Suitable for type HK 32H/
32B fuse base
Suitable for type
HK 63B/63H Fuse base
Suitable for type
FN 100/125/160 S-D-F
& for HK 125H/125B Fuse base
Suitable for type FN 200 S-D-F
Suitable for type FN 250/315 S-D-F
Suitable for type FN 400 S-D-F
Suitable for type FN 630 S-D-F
ST30725
ST30726
ST30727
ST30728
ST30729
ST30730
ST30731
ST30732
ST30736
ST30737
ST30738
ST30739
ST30740
ST30741
ST30742
ST30743
ST34527
ST34528
ST34529
ST35827
ST35828
ST30747
ST30748
ST30749
ST30750
ST30751
ST30752
ST30753
ST30759
ST30760
ST30761
ST30767
ST30768
ST30769
ST35829
ST30774
ST30775
ST30776
ST30777
ST30778
ST30779
ST30781
ST30782
ST30783
ST30784
ST30785
ST30786
ST30787
ST30788
M.R.P.
(`)
Per Unit
42
42
42
42
42
47
47
47
59
59
59
59
59
61
62
69
72
72
78
78
78
62
62
62
62
62
62
62
89
89
89
169
174
210
215
190
190
245
265
275
275
400
410
615
650
1115
1309
1375
1520
Std.
Pkg.
(Nos.)
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
15
15
15
15
15
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
3
3
3
3
3
3
3
1
1
1
1
Fuse holders suitable for bolted fuse-links
Rated
Current
(A)
20
32
HD 32H
HK 32H
HK 63H
HK 125H
63
125
24
Type
Connection Method
Fuse
Type
Suitable
Fuse
Range (A)
Cat. No.
Std.
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
HD 20H
Both side cable (Front)
F1
2-20
ST30772
105
12
HD 20P
Both side busbar (Back)
F1
2-20
ST30773
116
12
HD 20B
Top busbar & bottom cable
F1
2-20
ST30766
110
12
HD 32H
Both side cable (Front)
F1
2-32
ST30733
116
12
HD 32P
Both side busbar (Back)
F1
2-32
ST30734
147
12
HD 32B
Top busbar & bottom cable
F1
2-32
ST30735
137
12
HK 32H
Both side cable (Front)
A2
4-32
ST30754
179
12
HK 32B
Top busbar & bottom cable
A2
4-32
ST30755
210
12
HK 63H
Both side cable (Front)
A3
35-63
ST30762
240
6
HK 63B
Top busbar & bottom cable
A3
35-63
ST30763
290
6
HK 125H
Both side cable (Front)
A4
80-125
ST30770
745
3
HK 125B
Top busbar & bottom cable
A4
80-125
ST30771
815
3
L&T, ESP 01.11.2013
Switch-Disconnector-Fuse Units
Type FNX S-D-F suitable for DIN fuse-link in open execution
Features offered by FNX S-D-F
Range 32A to 800A, 415V, AC 23A
l TPN and FP version
l Suitable for cylindrical / DIN fuse-link
l Telescopic shaft for depth adjustment
l DIN rail mounting up to 100A
l Conforms to IEC 60947-3, IS/IEC 60947-3
l Door interlock & padlock facility
l
FNX TPN S-D-F
FNX 4P S-D-F
Suitable HRC fuse-link
Four Pole (FP)
Three pole + Neutral (TPN)
Rated
Current
(A)
Type
Range
(A)
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
32
HF
2 to 32
FNX 32 TPN / FP
SK96903
1685
1
FNX 32 TPN / FP
SK96903
1685
1
63
HF
2 to 63
FNX 63 TPN / FP
SK96904
2310
1
FNX 63 TPN / FP
SK96904
2310
1
100
HN Size 000
63 to 100
FNX 100 TPN / FP
SK96906
4565
1
FNX 100 TPN / FP
SK96906
4565
1
125
HN Size 000/00
63 to 125
FNX 125 TPN
SK95806
6285
1
FNX 125 FP
SK95814
6385
1
160
HN Size 000/00
63 to 160
FNX 160 TPN
SK95807
6845
1
FNX 160 FP
SK95815
7215
1
200
HN Size 0
80 to 200
FNX 200 TPN
SK95808
8705
1
FNX 200 FP
SK95816
9315
1
250
HN Size 1
125 to 250
FNX 250 TPN
SK95809
10440
1
FNX 250 FP
SK95817
10805
1
315
HN Size 1
125 to 315
FNX 315 TPN
SK95810
13085
1
FNX 315 FP
SK95818
13530
1
400
HN Size 2
200 to 400
FNX 400 TPN
SK95811
15560
1
FNX 400 FP
SK95819
16140
1
630
HN Size 3
315 to 630
FNX 630 TPN
SK95812
25150
1
FNX 630 FP
SK95820
25755
1
800
HN Size 3
315 to 800
FNX 800 TPN
SK95813
27260
1
FNX 800 FP
SK95821
28020
1
Type FN & FG Switch-Disconnector (TPN)
Type FFO/FF/FAC suitable for panel mounting
FN TPN S-D
Rated
Current
(A)
Std.
Pkg.
(Nos.)
Rated
Current
(A)
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1645
1
32
FFO TP Interior
SK91100
1175
1
Type
Cat. No.
M.R.P.
(`)
Per Unit
32
FN 32 TPN / 4P
SK95541
63
FN 63 TPN / 4P
SK95540
2240
1
63
FF TP Interior
SK91000
1780
1
100
FN 100 TPN
SK95571
4305
1
63
FAC 63 TPN
3300
1
125
FN 125 TPN
SK95405
5365
SK95156
1
200
FN 200 TPN
SK95607
7315
1
100
FAC 100 TPN
SK95157
5400
1
250
FN 250 TPN
SK95683
9320
1
315
FN 315 TPN
SK95609
10980
1
400
FN 400 TPN
SK95610
13555
1
630
FN 630 TPN
SK95611
20150
1
800
FN 800 TPN
SK95551
23335
1
1000
FN 1000 TPN
SK95710
30590
1
1000
FN 1000H TPN
SK95992
33740
1
1250
FG 1250 TPN
ST30198
49170
1
1600
FG 1600 TPN
ST30199
62350
1
Spares & Accessories for
Type FFO/FF/FAC
Rated
Current
(A)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
FAC - Handle Assembly
63 / 100
SK90453
70
1
32 / 63
SK90998
80
1
32 / 63
SK91079
400
1
Description
2000
FG 2000 TPN
ST30200
166570
1
FFO / FF Handle Assembly
2500
FG 2500 TPN
ST30201
197630
1
3150
FG 3150 TPN
ST30202
201305
1
FFO / FF Handle Coupler &
Door Interlock
Refer catalogue for short circuit withstand capacity
L&T, ESP 01.11.2013
25
Switch-Disconnector-Fuse: Accessories
Accessories for type FNX
Accessories for type FN
Castell Lock
DIN Rail Assembly
Terminal Shroud Kit
Handle Assembly
Auxiliary Contact Kit
Handle Assembly
Switched Neutral Kit
Shaft Extension Kit
Type
Description
Auxiliary Contact Kit
(1NO + 1 NC)
Handle Assembly
Castell Lock
DIN Rail Assembly
M.R.P. Std.
Pkg.
(`)
Per Unit (Nos.)
Cat. No.
Type
Description
Auxiliary Contact Kit
Cat. No.
M.R.P. Std.
Pkg.
(`)
Per Unit (Nos.)
FNX 32 / 63
SK91537
160
1
FN 32 / 63
SK91302
370
1
FNX 100
SK91538
310
1
Auxiliary Contact Kit
FN 100 / 125 / 160
SK91328
420
1
FNX 125 / 160
SK91539
310
1
(1NO + 1 NC)
FN 200 / 250
SK91329
495
1
FNX 200 / 250
SK91540
400
1
FN 315 / 400 / 630 / 800 SK91330*
545
1
FNX 315 / 400 / 630 / 800
SK91541
445
1
FN 32 / 63
SK91190
90
1
FNX 32 / 63 / 100
SK91524
270
1
FN 100 / 125 / 160
SK91137
120
1
FNX 125 / 160 / 200 / 250
SK91525
510
1
FN 200 / 250
SK91335
205
1
FNX 315 / 400 / 630 / 800
SK91526
640
1
FN 315 / 400
SK91346
215
1
FNX 32 / 63 / 100
SK91530
500
1
FN 630 / 800
SK91347*
225
1
FNX 125 / 160 / 200 / 250
SK91531
880
1
FN 32 / 63
SK91257
260
1
FNX 315 / 400 / 630 / 800
SK91531
880
1
FN 100 / 125 / 160
SK91258
570
1
FNX 32 / 63 / 100
SK91617
65
1
FN 200 / 250
SK91258
570
1
635
1
Terminal Shroud Kit
Handle Assembly - A
FN 315 / 400 / 630 / 800 SK91259*
Spare front housing assemblies for
FN S-D-F (suitable for DIN fuse-link)
Rating
(A)
Description
Cat. No.
Handle Assembly - B
FN 32 / 63
SK91277
260
1
FN 100 / 125 / 160
SK91278
570
1
FN 200 / 250
SK91278
570
1
635
1
SK91337
145
1
FN 100 / 125 / 160
SK95233
2415
1
FN 200 / 250
SK95516
2450
1
FN 315 / 400
SK95517
2545
1
FN 315 / 400 / 630 / 800 SK91279*
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Handle Assembly - CE FN 32 / 63
Switched Neutral Kit
100
FN 100 Front housing assembly
ST31677
2890
1
125
FN 125 Front housing assembly
ST31678
3380
1
FN 630 / 800
SK95546*
3430
1
200
FN 200 Front housing assembly
ST31679
3865
1
FN 200
SK91343
190
1
250
FN 250 Front housing assembly
ST31729
5250
1
FN 315 / 400
SK91344
200
1
315
FN 315 Front housing assembly
ST31681
6325
1
FN 630 / 800
SK91345*
210
1
400
FN 400 Front housing assembly
ST31682
7975
1
FN 100 / 125 / 160
SK95600
150
1
630
FN 630 Front housing assembly
ST31683
14310
1
180
1
Interphase Barrier Kit
Shaft Extension Kit
FN 315 / 400 / 630 / 800 SK91331*
* Also suitable for switch-disconnector FN1000 & FN1000H
Fuse pulling handle
For Type HN fuse-link
Castell lock for type FN
For Type HF fuse-link
Castell lock
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Fuse pulling handle for
HF Fuse-link from 2A-63A
SK91185
110
1
Insulated fuse pulling handle for
Type HN fuse-link from 63A-800A
SF90126
410
1
Description
Suitable
for
Type
FN 100
to FN 250
Type
FN 315
to FN 800
Description & Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
A = SK00333
C = SK00335
B = SK00334
D = SK00336
1500
2
A = SK00345*
C = SK00347*
B = SK00346*
D = SK00348*
1500
2
*Also suitable for Switch-Disconnector FN 1000 & FN 1000H
26
L&T, ESP 01.11.2013
On Load Changeover Switch - Disconnectors
Type
changeover switch-disconnector
Direct handle F1
Extended handle F1
as open execution
Features offered by
Changeover
l Range 63A to 1000A, 415V, AC 23A, 4P
l Conforms to IEC 60947-3, IS/IEC 60947-3
l Staggered terminals
l Site convertible fuse version for open execution
l Flip-able handle above 400A
l Interchangeable dual shaft position with site convertibility
l SS enclosure version does not require separate cable
gland box
in SS enclosure
#
Open Execution
In Sheet Steel Enclosure
Rated
Current
(A)
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
63
CO1-63
CO10630OOOO
1
CO1-63
CO10630OOOD*
4295
63
3950
1
100
CO1-100
CO11000OOOO
1
CO1-100
CO11000OOOD*
5470
100
5070
1
125
CO2-125
CO21250OOOO
8160
160
CO2-160
CO21600OOOO
9010
200
CO2-200
CO22000OOOO
250
CO3-250
315
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
CO1-63
CO10630OSOO
6150
1
CO1-100
CO11000OSOO
7435
1
1
CO2-125
CO21250OSOO
10945
1
1
CO2-160
CO21600OSOO
12030
1
10870
1
CO2-200
CO22000OSOO
13535
1
CO32500OOOO
15365
1
CO3-250
CO32500OSOO
19245
1
CO3-315
CO33150OOOO
16265
1
CO3-315
CO33150OSOO
20160
1
400
CO4-400
CO44000OOOO
23990
1
CO4-400
CO44000OSOO
29565
1
630
CO4-630
CO46300OOOO
28670
1
630
CO5-630
CO56300OOOO
30000
1
CO4-630
CO46300OSOO
34125
1
800
CO5-800
CO58000OOOO
42515
1
CO5-800
CO58000OSOO
51490
1
1000
CO5-1000
CO51000OOOO
68620
1
CO5-1000
CO51000OSOO
87050
1
*
Direct handle version
# All sheet steel enclosure version are with extended handle switch
ew
Type
in fuse version N
Fuse mountable kit (suitable for DIN fuse-link)
Type FG / FGC (TPN) changeover
switch-disconnector
Fuse Mountable Kit
FGC Changeover
Rated
Current
(A)
Type
Description
Cat. No.
M.R.P.
Std.
Pkg.
(`)
Per Unit (Nos.)
1250
Back to Back mtg. with
FGC 1250 4 O/P terminals
ST27460OOOC 102235
1600
Back to Back mtg. with
ST27470OOOO 141080
8 O/P terminals
FG 1600
1
1
Spares & Accessories for type
/ FG / FGC Auxiliary contact
63
HF
CX10630OOCO
1100
1
125
Size 000
CO Frame 2 125A CX21250OODO
2820
1
160
Size 00
CO Frame 2 160A CX21600OODO
3735
1
200
Size 00
CO Frame 2 200A CX22000OODO
4765
1
250
Size 1
CO Frame 3 250A CX32500OODO
5115
1
315
Size 1
CO Frame 3 315A CX33150OODO
5360
1
400
Size 2
CO Frame 4 400A CX44000OODO
7820
1
630
Size 3
CO Frame 5 630A CX56300OODO
16890
1
800
Size 3
CO Frame 5 800A CX58000OODO
18870
1
CO Frame 1 63A
Operating Handle (63A to 315A)
Auxiliary
Contact
Cat. No.
C/O Frame 1 (63-100A)
2 NO + 2 NC CX10002OOOO
C/O Frame 2 (125-200A)
2 NO + 2 NC CX20002OOOO
C/O Frame 3 (250-315A)
M.R.P.
Std.
Pkg.
(`)
Per Unit (Nos.)
Cat. No.
Operating Handle
Auxiliary Contact
Auxiliary contact block
suitable for
Rated
Suitable
Current fuse-link type Fuse Mountable Kit
(A)
DIN
M.R.P. Std.
Pkg.
(`)
Per Unit (Nos.)
Operating handle
suitable for
Flip-able Handle (400A to 1000A)
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1
C/O Frame 1 (63-100A)
CX10001OOOO
450
1
605
1
C/O Frame 2 & 3 (125-315A)
CX30001OOOO
800
1
2 NO + 2 NC CX30002OOOO
660
1
C/O Frame 4 (400-630A)
CX40001OOOO
1050
1
C/O Frame 4 (400-630A)
2 NO + 2 NC CX40002OOOO
695
1
C/O Frame 5 (800-1000A)
CX50001OOOO
1145
1
C/O Frame 5 (800-1000A)
2 NO + 2 NC CX50002OOOO
795
1
FG Isolator 1000 / 1250 / 1600A
ST26591OOOO
2750
1
FG & FGC (250 - 1600A)
1 NO + 1 NC ST26542OOOO
782
1
FGC C/O 1000 / 1250A
ST26591OOOC
2750
1
28
400
L&T, ESP 01.11.2013
MCCB Range
l
l
l
l
l
Conforms to IS/IEC 60947-2 & IEC 60947-2
Comprehensive range from 0.63A to 1250A
1, 2, 3 & 4 pole versions
Breaking capacities upto 70kA
Manual & Electrical operation
l
l
l
l
l
l
l
Use of phase barriers is mandatory. These are supplied
along with MCCBs
It is recommended to use spreader terminals for enhancing
termination capacity
Spreader terminals are available as accessories, unless
otherwise specified against Cat. Nos.
Spreaders are made of silver plated copper
Protection units:
- Thermal Magnetic
- Microprocessor based
- Microprocessor based with communication & metering
Comprehensive range of internal & external accessories
Solution for ASTS (Automatic Source Transfer System)
Special Applications
l
For DC application, 2P MCCBs are available
l
For Capacitor back up protection, MCCBs are available
l
l
For Motor backup protection, use ‘M’ series of MCCBs such as
DM, DN0-M, DN2-M, DN3-M
For isolation, use SD version (without protection release)
DU MCCB Range
Rating (A)
16
20
32
25
40
63
50
80
100
125
160
200
250
Icu (kA)
DU100
10
30
DU100H
36
DU250
DU100 MCCB
l
l
l
l
l
Type
DU100
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 16A to 100A, 2P & 3P
Compact size
Also available in SS Enclosure
Suitable for mounting on D-Pan assembly
Breaking
Capacity
Icu at 415V AC
50Hz. (kA)
Current
Rating
(A)
2 Pole
New
3 Pole
Std.
Pkg.
(Nos.)
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
16
CM97795OOOO
1115
CM97751OOOO
1600
1
20
CM97796OOOO
1115
CM97752OOOO
1600
1
25
CM97797OOOO
1115
CM97753OOOO
1600
1
32
CM97798OOOO
1115
CM97754OOOO
1600
5*
CM97799OOOO
1115
CM97755OOOO
1600
1
50
CM97800OOOO
1115
CM97756OOOO
1600
1
63
CM97801OOOO
1115
CM97757OOOO
1600
5*
80
CM97802OOOO
1225 p CM98921OOOO
1750 p
1
100
CM97803OOOO
1225 p CM98922OOOO
1750 p
5*
40
10
p- Spreader Terminals are included
* - For 3P MCCBs
Note: 2P in 3P frame size
DU100H MCCB
l
l
l
l
Type
DU100H
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 20A to 100A, 2P, 3P & 4P
Compact size
Also available in SS Enclosure
Thermal
Release
Range (A)
Breaking Capacity
Icu at 415V AC
50Hz. (kA)
2 Pole
Suitable for mounting on D-Pan assembly
Wide Range of snap fit Internal and
External Accessories
Adjustable Overload Setting: 0.8 - 1.0 x In
l
l
l
New
3 Pole
4 Pole
Std.
Pkg.
(Nos.)
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
2800
CM97894OOC2
4110
CM97933OOC2
5550
1
2800
CM97894OOD2
4110
CM97933OOD2
5550
1
CM97898OOE2
2800
CM97894OOE2
4110
CM97933OOE2
5550
1
CM97898OOF2
2800
CM97894OOF2
4110
CM97933OOF2
5550
1
CM97898OOG2
2800
CM97894OOG2
4110
CM97933OOG2
5550
1
50-63
CM97898OOH2
2800
CM97894OOH2
4110
CM97933OOH2
5550
1
63-80
CM97898OOJ2
2800
CM97894OOJ2
4110
CM97933OOJ2
5550
1
80-100
CM97898OOK2
2800
CM97894OOK2
4110
CM97933OOK2
5550
1
Cat. No.
M.R.P.
(`)
Per Unit
16-20
CM97898OOC2
20-25
CM97898OOD2
25-32
32-40
30
40-50
Note: 2P in 3P frame size
For higher rating 2P MCCBs, please contact nearest branch
DU250 MCCB
l
l
l
l
l
Type
DU250
30
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 100A to 250A, 3P & 4P
Compact size
Wide Range of snap fit Internal and External Accessories
Adjustable Overload Setting: 0.8 - 1.0 x In
Thermal
Release
Range (A)
Breaking Capacity
Icu at 415V AC
50Hz. (kA)
3 Pole
4 Pole
Std.
Pkg.
(Nos.)
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
80-100
CM98064OOOO
5210
CM98065OOKO
7010
1
100-125
CM98063OOOO
5810
CM98065OOLO
7650
1
CM98062OOOO
7650
CM98065OOMO
9390
1
160-200
CM98061OOOO
10100
CM98065OONO
13100
1
200-250
CM98060OOOO
11780
CM98065OOPO
15300
1
125-160
36
L&T, ESP 01.11.2013
Accessories for DU MCCBs
Accessories for DU100
Auxiliary Contact
Shunt Release
Direct Rotary Handle
Spreader Terminals
Internal
External
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1 C/O - Right
CM97781OOOO
405
1
3 Pole
1 C/O - Left
CM97782OOOO
405
1
Rotary Handle
CM97783OOOO
500
1
Description
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
CM97785OOOO
195
Set of 6
SL97044OOOO
750
1
Spreader Terminals
Auxiliary Contact
Direct
Shunt Release
240/415V AC - Left
Note: Phase Barriers are supplied along with MCCBs
Accessories for DU100H/DU250
Auxiliary Contact
ATAC
Shunt Release
UV Release
Direct Rotary Handle
Spreader Terminals
Extended Rotary Handle
Internal
External
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1 C/O - Right
CM97886OOOO
695
1
2 C/O - Right
CM97887OOOO
1180
1
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
DU100H - 3 Pole
CM97785OOOO
195
Set of 6
DU100H - 4 Pole
CM97921OOOO
265
Set of 8
DU250 - 3 Pole
ST98053OOOO
1035
Set of 6
CM92007OOOO
1260
Set of 8
Description
Spreader Terminals
Auxiliary Contact
Trip Alarm Contact
1 C/O - Right
CM97888OOOO
695
1
DU250 - 4 Pole
2 C/O - Right
CM97889OOOO
1180
1
Rotary Handle
CM97890OOOO
1180
1
Auxiliary 1 C/O + TAC 1 C/O
Right
Shunt Release
240/415V AC - Left
CM97883OMOO
990
1
CM97892BOOO
1330
1
Under Voltage Release
240V AC - Left
DU100H - Direct
CM97895OOOO
950
1
DU250 - Direct
CM98040OOOO
1015
1
DU100H - Extended
CM97896OOOO
1410
1
DU250 - Extended
CM98041OOOO
1450
1
Note: Phase Barriers are supplied along with MCCBs
D-Pan Assembly
l
l
l
l
Offers a convenient solution for distribution
Available for 250A, 400A main incomer 3P
MCCBs
Available for 4, 8 & 12 ways 3P outgoing MCCBs
Type tested (
)
O/G - DU100
Description
I/C -
Cat. No.
O/G - DN0 / DU100H
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
D-Pan I/C 250A O/G 4 Way
CM97821OOOO
9105
CM97912OOOO
9105
1
D-Pan I/C 250A O/G 8 Way
CM97822OOOO
12750
CM97913OOOO
12750
1
D-Pan I/C 250A O/G 12 Way
CM97823OOOO
16485
CM97914OOOO
16485
1
D-Pan I/C 400A O/G 4 Way
CM98605OOOO
10660
CM97915OOOO
10660
1
D-Pan I/C 400A O/G 8 Way
CM98606OOOO
14300
CM97916OOOO
14300
1
D-Pan I/C 400A O/G 12 Way
CM98607OOOO
18030
CM97917OOOO
18030
1
Note: MCCBs and shroud are shown for representation purpose only, need to be purchased separately.
L&T, ESP 01.11.2013
31
DH
DU MCCB
(DU125/160/200)
Range MCCB Range
l
l
l
l
l
Type
Thermal
Release
Range
(A)
DU125 #
100-125
DU160 #
128-160
DU200 #
160-200
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 125A to 200A, 3P & 4P
Adjustable thermal setting: 0.8-1.0 x In
Also available in SS Enclosure
Wide range of Internal and External Accessories
3 Pole
Breaking
Capacity Icu
at 415V. AC,
50Hz. (kA)
CM97791OOOO
CM98110OOOO
M.R.P.
(`)
Per Unit
8750 p
CM97792OOOO
8790 p
CM98111OOOO
10640 p
CM97793OOOO
11500 p
-
Cat. No.
30
4 Pole
M.R.P.
(`)
Per Unit
6850 p
Cat. No.
Std.
Pkg.
(Nos.)
1
1
1
-
p- Spreader Terminals are included
# - Available till stocks last
DH MCCB Range
Rating (A)
Icu (kA)
25
16
20
25
32
40
63
80
100
125
160
l
l
l
l
l
Thermal
Release
Range
(A)
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
3 Pole
4 Pole
Std.
Pkg.
(Nos.)
Cat. No.
Cat. No.
12-16
SL97201OOOO
4720
SL98597OOOO
6400
1
16-20
SL97202OOOO
4720
SL98598OOOO
6400
1
20-25
SL97203OOOO
4720
SL98599OOOO
6400
1
25-32
SL97204OOOO
4720
SL98600OOOO
6400
1
32-40
SL97205OOOO
4720
SL98601OOOO
6400
1
SL97206OOOO
4720
SL98602OOOO
6400
1
50-63
SL97207OOOO
4720
SL98603OOOO
6400
1
63-80
SL97208OOOO
4720
SL98604OOOO
6400
1
80-100
SL97209OOOO
4970 p
SL98605OOOO
6740p
1
12-16
SL98644OOOO
6200
SL98611OOOO
7060
1
16-20
SL98645OOOO
6200
SL98612OOOO
7060
1
20-25
SL98646OOOO
6200
SL98613OOOO
7060
1
25-32
SL98647OOOO
6200
SL98614OOOO
7060
1
32-40
SL98648OOOO
6200
SL98615OOOO
7060
1
40-50
SL98649OOOO
6200
SL98616OOOO
7060
1
50-63
SL98650OOOO
6200
SL98617OOOO
7060
1
SL98651OOOO
6200
SL98618OOOO
7060
1
SL98652OOOO
6920 p
SL98619OOOO
7890 p
1
100-125
SL98653OOOO
7060 p
SL98607OOOO
8120 p
1
DH160 #
128-160
SL98654OOOO
9950 p
SL98608OOOO
10760 p
1
DH200 #
160-200
SL98655OOOO
11920 p
250-320
SL97883OOOO
20900 p
320-400
SL97884OOOO
20900 p
400-500
SL94531OOOO
24230 p
500-630
SL94532OOOO
24230 p
40-50
63-80
80-100
DH630 #
630
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 16A to 630A, 3P & 4P
Ics = 100% Icu@
Adjustable thermal setting: 0.8-1.0 x In
Also available in SS Enclosure for DH100/125/160/200
Wide Range of Internal and External Accessories
M.R.P.
(`)
Per Unit
DH400 #
500
DH400/630
M.R.P.
(`)
Per Unit
DH125
400
DL100
l
DH100
320
DH125/160/200
50
Type
200
DH100
35
32
50
25
35
Note: For 2P MCCB, please contact nearest branch
 - Spreader Terminals are included
@ - Refer Catalogue for DH160, DH200
# - Available till stocks last
L&T, ESP 01.11.2013
DL MCCB Range
l
l
l
l
l
l
Type
DL100
Thermal
Release
Range
(A)
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 16A to 100A, 3P & 4P
Ics = 100% Icu
Adjustable thermal setting: 0.8-1.0 x In
Wide Range of Internal and External Accessories
For Icu=65 kA, please contact branch office
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
3 Pole
4 Pole
Std.
Pkg.
(Nos.)
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
12-16
SL97801OOOO
9200
SL98620OOOO
10460
1
16-20
SL97802OOOO
9200
SL98621OOOO
10460
1
20-25
SL97803OOOO
9200
SL98622OOOO
10460
1
25-32
SL97804OOOO
9200
SL98623OOOO
10460
1
SL97805OOOO
9200
SL98624OOOO
10460
1
40-50
SL97806OOOO
9200
SL98625OOOO
10460
1
50-63
SL97807OOOO
9200
SL98626OOOO
10460
1
63-80
SL97808OOOO
9200
SL98627OOOO
10460
1
80-100
SL97809OOOO
10170p
SL98628OOOO
11530p
1
32-40
50
- Spreader Terminals are included
DM MCCB Range for Motor Back-up Protection
l
l
l
l
MCCB
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 0.63A to 400A, 65kA
Short Circuit Protection : 12 In
Wide Range of Internal and External Accessories
Starter
Representative Application Image
M
3 Pole
Type
DM16
Current
Rating
(A)
3 Pole
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
0.63
SL97581OOOO
3515
1
1.0
SL97582OOOO
3515
1
1.6
SL97583OOOO
3515
2.5
SL97584OOOO
4.0
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
100.0
SL97123OOOO
13875
1
120.0
SL97703OOOO
13875
1
1
160.0
SL97124OOOO
13875
1
3515
1
200.0
SL97551OOOO
1
SL97585OOOO
3515
1
230.0
SL97552OOOO
17895 p
17895 p
5.0
SL97586OOOO
3515
1
250.0
1
6.3
SL97587OOOO
3515
1
275.0
SL97554OOOO
17895 p
21100 p
7.5
SL97588OOOO
3515
1
325.0
SL97555OOOO
1
10.0
SL97589OOOO
3515
1
350.0
SL97556OOOO
21100 p
21100 p
SL97590OOOO
3515
1
400.0
SL97557OOOO
21100 p
1
16.0
SL97591OOOO
3515
1
16.0
SL97811OOOO
8790
1
25.0
SL97812OOOO
8790
1
30.0
SL97816OOOO
8790
1
35.0
SL97813OOOO
8790
1
50.0
SL97814OOOO
8790
1
60.0
SL97817OOOO
8790
1
70.0
SL97815OOOO
8790
1
80.0
SL97987OOOO
8790
1
L&T, ESP 01.11.2013
65
Type
DM160
DM250
DM400
Current
Rating
(A)
Breaking
Capacity Icu
at 415V,
50Hz (kA)
Cat. No.
12.0
DM100
Breaking
Capacity Icu
at 415V,
50Hz (kA)
65
SL97553OOOO
1
1
1
p - Spreader Terminals are included
Note: Please contact nearest branch office for fuseless type 2
co-ordination selection chart
33
DTH MCCB Range
l
l
l
l
l
Conforms to IS/IEC 60947-2 & IEC 60947-2
Suitable for distribution & induction furnace application
Rugged construction
Adjustable thermal setting : 600 - 800A
Adjustable magnetic setting : 2600 - 6400A
Type
3 Pole (for Distribution Application)
Type
DTH800
Thermal
Release
Range
(A)
Breaking
Capacity Icu
at 415V,
50Hz (kA)
Cat. No.
600-800
50
SL94472OOOO
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
39260
1
DTH800 Instantaneous
3 Pole (for Induction Furnace Application)
Breaking
Current Instantaneous
Capacity Icu
Setting
Rating
Cat. No.
at 415V,
(A)
(A)
50Hz (kA)
M.R.P. Std.
Pkg.
(`)
Per Unit (Nos.)
250
360
50
SB95052OOOO 39260
1
400
550
50
SB95053OOOO 39260
1
630
850
50
SB95054OOOO 39260
1
800
1050
50
SB95055OOOO 39260
1
Accessories for DH100/125/160/200, DU125/160/200,
DL100, DM100 MCCBs
Auxiliary Contact
TAC
UV Release
Shunt Release
Spreader Terminal
Extended Rotary Handle
Internal
External
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1 C/O - Right
SL97296OOOO
765
1
1 C/O - Left
SL97297OOOO
765
1
Description
Auxiliary Contact
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
3 Pole
ST98047OOOO
335
Set of 6
4 Pole
ST98060OOOO
440
Set of 8
CM99103OOOO
1235
1
Spreader Terminals
Rotary Handle
Trip Alarm Contact
SL97298OOOO
765
1
240V AC - Left
SL97299OMOO
955
1
24V DC - Left *
SL97299O4OO
955
1
SL97611OOOO
1280
1
1 C/O - Right
Cat. No.
Description
Shunt Release
Extended - New look
* Not available for DU MCCBs
Note: Phase Barriers are supplied along with MCCBs
Under Voltage Release
240V AC - Left
Accessories for DM16 MCCB
Auxiliary Contact
Direct Rotary Handle
Shunt Release
Extended Rotary Handle
Internal
Description
External
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1 C/O - Right
SL97023OOOO
550
1
Direct
1 C/O - Left
SL97025OOOO
550
1
Extended - New look
SL97037OOOO
550
1
SL97042OOOO
610
1
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SL97044OOOO
750
1
CM99918OOOO
1390
1
Cat. No.
Rotary Handle
Auxiliary Contact
Trip Alarm Contact
1 C/O - Right
Shunt Release
240 / 415V AC, 110V DC - Left
34
L&T, ESP 01.11.2013
Accessories for DM160 MCCB
Auxiliary Contact
UV Release
Shunt Release
Extended Rotary Handle
External
Internal
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
2 C/O - Left
SL94329OOOO
1675
1
2 C/O - Right
SL94330OOOO
1675
1
415V AC - Right
SL94331ODOO
1660
1
240V AC - Right
SL94331OBOO
1660
1
SL94332DOOO
SL94332BOOO
1660
1660
1
1
Description
Cat. No.
M.R.P.
(`)
Per Unit
CM99102OOOO
1500
Std.
Pkg.
(Nos.)
Rotary Handle
Auxiliary Contact
Shunt Release
Extended - New look
1
Note: For (DM160+TAC), please contact nearest branch office
Under Voltage Release
415V AC - Left
240V AC - Left
Accessories for DM250/400 & DH400/630 MCCBs
Auxiliary Contact
Description
Direct Rotary Handle
UV Release
Shunt Release
Internal
M.R.P.
(`)
Cat. No.
Per Unit
Std.
Pkg.
(Nos.)
SL97573OOOO
1150
1
Trip Alarm Contact
1 C/O - Right
External
M.R.P.
(`)
Cat. No.
Per Unit
Description
Std.
Pkg.
(Nos.)
Rotary Handle
Auxiliary Contact
2 C/O
Extended Rotary Handle
SL97574OOOO
1150
DM250/400 & DH400 Direct
SL97562OOOO
965
1
DH630 Direct
SL97979OOOO
1155
1
CM99101OOOO
2350
1
ST98045OOOO
2330
Set of 6
DM250/400 & DH400 / 630 Extended
1
Shunt Release
- New look
415V AC, 220V DC
SL97575OOOO
1340
1
Spreader Terminals
240V AC, 110V DC
SL97576OOOO
1340
1
DM250/400 - 3 Pole
415V AC - Left
SL97579OOOO
1545
1
240V AC - Left
SL97580OOOO
1545
1
Under Voltage Release
Note: Phase Barriers are supplied along with MCCBs
Accessories for DTH 630/800 MCCBs
UV Release
Shunt Release
Extended Rotary Handle
Auxiliary Contact
External
Internal
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
SL94217OOOO
1515
1
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Rotary Handle
Auxiliary Contact
2 C/O
Description
Shunt Release
415V AC, 220V DC - Right
SL98526OOOO
1810
1
240V AC, 110V DC - Right
SL98534OOOO
1810
1
415V AC - Left
SL98548OOOO
1810
1
240V AC - Left
SL98545OOOO
1810
1
110V AC - Left
SL98543OOOO
1810
1
Extended - New look
CM99898OOOO
2410
1
Note: For (DTH800+TAC), please contact nearest branch office
Under Voltage Release
L&T, ESP 01.11.2013
35
SS Enclosure for DU / DH / DL / DM
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
DU100 SS Enclosure
ST98050OOOO
770
1
DU100H SS Enclosure
ST42021OOOO
770
1
DH100/125/160/200,DL100, DM100,
ST29967OOOO
DU125/160/200 SS Enclosure
1400
1
Description
Note : Suitable for 3P MCCBs
DU100 / 100H SS Enclosure
DH / DL / DM / DU SS Enclosure
Ground Fault Module
l
l
Provides protection against ground fault
GF Module for ground fault protection can be used with all
Thermal Magnetic MCCBs
l
Adjustable ground fault sensitivity selection: 10% - 50% of In
l
Adjustable time delay: 100ms / 200ms
l
l
l
Test facility to check healthiness of ground fault protection
system without tripping MCCB
Suitable for 3 phase 3 wire & 3 phase 4 wire electrical
distribution network
LED for earth fault indication
Ground Fault Protection
Type
Range
(A)
Cat. No.
M.R.P.
(`)
Per Unit
CT
Std.
Pkg.
(Nos.)
GF1
100 - 200A
ST27745OOOO
6035
Built in CBCT
1
GF2
250 - 400A
ST27746OOOO
9175
Built in CBCT
1
GF11
up to 800A
ST28594OOOO
5500 #
External CT required
1
# External CTs of 5P10 class with secondary rating of 1A or 5A
36
L&T, ESP 01.11.2013
MCCB Range
With Thermal - Magnetic Release :
Rating (A)
New
Icu (kA)
20
25
32
40
50
63
80 100 125 160 200 250 320 400 500 630
DN0
25/36
DN1
50
DN4
DN3
l
l
l
l
l
l
l
l
l
Type
DN0-100D*
DN1-250N*
New
DN0-100C
DN2-250D
DN3-400D
DN3-630D
DN2-250N
DN3-400N
DN3-630N
DN2-250S
DN3-400S
DN3-630S
DN2
DN1
DN0
DN2
36/50/70
DN3
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 20A to 630A, 3P & 4P
Choice of 25kA / 36kA / 50kA / 70kA breaking capacities
Ics = 100% Icu*
Suitable for Isolation
Adjustable Over Load setting: 0.8 - 1.0 x In
Adjustable Short Circuit setting: 6 - 10 x In**
Manual, Rotary or Motorised versions available @
Wide Range of snap fit Internal and External Accessories
Thermal
Release
Range
(A)
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
4 Pole
3 Pole
Std.
Pkg.
(Nos.)
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
16-20
CM97893OOC2OG
4940
CM97919OOC2OG
6670
1
20-25
CM97893OOD2OG
4940
CM97919OOD2OG
6670
1
25-32
CM97893OOE2OG
4940
CM97919OOE2OG
6670
1
32-40
CM97893OOF2OG
4940
CM97919OOF2OG
6670
1
CM97893OOG2OG
4940
CM97919OOG2OG
6670
1
50-63
CM97893OOH2OG
4940
CM97919OOH2OG
6670
1
63-80
CM97893OOJ2OG
4940
CM97919OOJ2OG
6670
1
80-100
CM97893OOK2OG
4940
CM97919OOK2OG
6670
1
100 - 125
CM98608OOLO
8780
CM98613OOLO
11390
1
125 - 160
CM98608OOMO
11210
CM98613OOMO
14420
1
CM98608OONO
15090
CM98613OONO
#
1
200 - 250
CM98608OOPO
17690
CM98613OOPO
#
1
16-20
CM91612OOCOOG
5410
CM91712OOCOOG
7340
1
20-25
CM91612OODOOG
5410
CM91712OODOOG
7340
1
25-32
CM91612OOEOOG
5410
CM91712OOEOOG
7340
1
32-40
CM91612OOFOOG
5410
CM91712OOFOOG
7340
1
CM91612OOGOOG
5410
CM91712OOGOOG
7340
1
50-63
CM91612OOHOOG
5410
CM91712OOHOOG
7340
1
63-80
CM91612OOJOOG
5410
CM91712OOJOOG
7340
1
80-100
CM91612OOKOOG
5410
CM91712OOKOOG
7340
1
100-125
CM92008OOL1OG
9990
CM92108OOL1OG
12230
1
125-160
CM92008OOM1OG
12650
CM92108OOM1OG
14800
1
160-200
CM92009OON1OG
17670
CM92109OON1OG
20930
1
200-250
CM92009OOP1OG
18780
CM92109OOP1OG
22600
1
CM94005OOQ1OG
22790
CM94105OOQ1OG
28550
1
320-400
CM94005OOR1OG
22980
CM94105OOR1OG
28810
1
400-500
CM94006OOS1OG
26400
CM94106OOS1OG
33300
1
500-630
CM94006OOT1OG
28180
CM94106OOT1OG
35140
1
100-125
CM92005OOL1OG
12540
CM92105OOL1OG
16240
1
125-160
CM92005OOM1OG
15540
CM92105OOM1OG
18230
1
160-200
CM92006OON1OG
19960
CM92106OON1OG
25200
1
200-250
CM92006OOP1OG
21150
CM92106OOP1OG
26250
1
CM94003OOQ1OG
24440
CM94103OOQ1OG
30200
1
320-400
CM94003OOR1OG
24520
CM94103OOR1OG
30610
1
400-500
CM94004OOS1OG
28700
CM94104OOS1OG
36760
1
500-630
CM94004OOT1OG
30760
CM94104OOT1OG
39000
1
100-125
CM92002OOL1OG
16830
CM92102OOL1OG
19330
1
125-160
CM92002OOM1OG
19850
CM92102OOM1OG
24040
1
160-200
CM92003OON1OG
23110
CM92103OON1OG
30010
1
200-250
CM92003OOP1OG
24210
CM92103OOP1OG
30730
1
CM94001OOQ1OG
28000
CM94101OOQ1OG
32010
1
320-400
CM94001OOR1OG
28140
CM94101OOR1OG
32450
1
400-500
CM94002OOS1OG
35890
CM94102OOS1OG
43990
1
500-630
CM94002OOT1OG
37790
CM94102OOT1OG
46690
1
40-50
160 - 200
40-50
250-320
250-320
250-320
L&T, ESP 01.11.2013
36
50
25
36
50
70
Note: For 800A TM release please refer
DTH MCCBs, page No. 34
For higher ratings, please refer
microprocessor release MCCBs,
page No. 38, 39
Breaking Capacity - C = 25kA, D = 36kA,
N = 50kA, S = 70kA
@ Motorised version available for DN2 and
DN3 frames (please refer page No. 41)
* For DN0-100D, DN1-250N : Ics = 50% Icu
**For DN0, DN1-Short Circuit Setting : 9In
# Available on request
37
MCCB Range
With Microprocessor Release :
Rating (A)
Icu (kA)
40
50
63
80
100
125
160
200
250
320
400
800
1000 1250
DN3
DN2
36/50/70
630
500
DN4
50/70
With Microprocessor Release MTX1.0 :
l
l
l
l
l
l
l
l
l
l
Release
Range
(A)
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
3 Pole
4 Pole
Cat. No.
Cat. No.
M.R.P.
(`)
Per Unit
16 - 40
CM92063OOOOX1
13230
CM92155OOOOX1
17130
1
25 - 63
CM92071OOOOX1
13230
CM92154OOOOX1
17130
1
40 - 100
CM92051OOOOX1
13230
CM92153OOOOX1
17130
1
CM92074OOOOX1
15730
CM92152OOOOX1
21350
1
100 - 250
CM92054OOOOX1
22020
CM92151OOOOX1
28720
1
DN3-400D
160 - 400
CM93001OOOOX1
27260
CM93003OOOOX1
32720
1
DN3-630D
250 - 630
CM93005OOOOX1
30230
CM93007OOOOX1
39680
1
16 - 40
CM92064OOOOX1
15140
CM92160OOOOX1
19150
1
25 - 63
CM92072OOOOX1
15140
CM92159OOOOX1
19150
1
40 - 100
CM92052OOOOX1
15140
CM92158OOOOX1
19150
1
63 - 160
CM92075OOOOX1
19430
CM92157OOOOX1
24340
1
100 - 250
CM92055OOOOX1
24030
CM92156OOOOX1
31640
1
CM93002OOOOX1
29380
CM93004OOOOX1
37180
1
DN2-250D
63 - 160
DN2-250N
36
50
DN3-400N
160 - 400
DN3-630N
250 - 630
CM93006OOOOX1
32570
CM93008OOOOX1
43360
1
320 - 800
CM96021OOOOX1
50030
CM96111OOOOX1
62180
1
400 - 1000
CM96022OOOOX1
66880
CM96112OOOOX1
95770
1
500 - 1250
CM96023OOOOX1
83350
CM96113OOOOX1
122130
1
16 - 40
CM92065OOOOX1
18180
CM92165OOOOX1
22270
1
DN4-1250N
DN2-250S
25 - 63
CM92073OOOOX1
18180
CM92164OOOOX1
22270
1
40 - 100
CM92059OOOOX1
18180
CM92163OOOOX1
22270
1
63 - 160
CM92076OOOOX1
24510
CM92162OOOOX1
31290
1
100 - 250
CM92056OOOOX1
30600
CM92161OOOOX1
35840
1
CM94053OOOOX1
35040
CM94153OOOOX1
45360
1
70
DN3-400S
160 - 400
DN3-630S
250 - 630
CM94079OOOOX1
39600
CM94179OOOOX1
50660
1
320 - 800
CM96025OOOOX1
58630
CM96115OOOOX1
71500
1
400 - 1000
CM96026OOOOX1
82670
CM96116OOOOX1
118130
1
500 - 1250
CM96027OOOOX1
104060
CM96117OOOOX1
141700
1
DN4-1250S
cut
In
630A
Std.
Pkg.
(Nos.)
M.R.P.
(`)
Per Unit
Type
0.2
Inst
l
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 40A to 1250A, 3P & 4P
Choice of 36kA / 50kA / 70kA breaking capacities
0.4
Ics = 100% Icu
Suitable for Isolation
Adjustable Over Load from 0.4 - 1.0 x In
DN3
Adjustable Short Circuit from 1.5 - 8 x Ir
MTX 1.0
Inbuilt Instantaneous Protection
Provision of Thermal Memory : ON/OFF
Variable trip class at 7.2 Ir & 6 Ir
Front LED indication of Over Load (Ready, Over load pre-alarm & Overload)
Manual, Rotary or Motorised versions available @
Wide Range of snap fit Internal and External Accessories
r
l
r
l
@ Motorised version available for DN2 and DN3 frames (please refer page No. 41)
38
L&T, ESP 01.11.2013
MCCB Range
With Microprocessor Release MTX2.0 :
l
l
l
l
l
l
l
l
l
l
l
l
l
Release
Range
(A)
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
3 Pole
4 Pole
0.2
Cat. No.
Cat. No.
M.R.P.
(`)
Per Unit
16 - 40
CM92063OOOOAG
23700
CM92155OOOOAG
27520
1
25 - 63
CM92071OOOOAG
23700
CM92154OOOOAG
27520
1
40 - 100
CM92051OOOOAG
23700
CM92153OOOOAG
27520
1
CM92074OOOOAG
27140
CM92152OOOOAG
33650
1
100 - 250
CM92054OOOOAG
32400
CM92151OOOOAG
39870
1
DN3-400D
160 - 400
CM93001OOOOAG
37800
CM93003OOOOAG
44200
1
DN3-630D
250 - 630
CM93005OOOOAG
40730
CM93007OOOOAG
51410
1
16 - 40
CM92064OOOOAG
25990
CM92160OOOOAG
29990
1
25 - 63
CM92072OOOOAG
25990
CM92159OOOOAG
29990
1
40 - 100
CM92052OOOOAG
25990
CM92158OOOOAG
29990
1
63 - 160
CM92075OOOOAG
30740
CM92157OOOOAG
36630
1
100 - 250
CM92055OOOOAG
34270
CM92156OOOOAG
43400
1
CM93002OOOOAG
39270
CM93004OOOOAG
47800
1
DN2-250D
63 - 160
DN2-250N
36
50
DN3-400N
160 - 400
DN3-630N
250 - 630
CM93006OOOOAG
44320
CM93008OOOOAG
57290
1
320 - 800
CM96021OOOOAG
65190
CM96111OOOOAG
78120
1
400 - 1000
CM96022OOOOAG
83400
CM96112OOOOAG
111600
1
500 - 1250
CM96023OOOOAG
104450
CM96113OOOOAG
145150
1
16 - 40
CM92065OOOOAG
28790
CM92165OOOOAG
33330
1
DN4-1250N
DN2-250S
25 - 63
CM92073OOOOAG
28790
CM92164OOOOAG
33330
1
40 - 100
CM92059OOOOAG
28790
CM92163OOOOAG
33330
1
63 - 160
CM92076OOOOAG
36160
CM92162OOOOAG
43890
1
100 - 250
CM92056OOOOAG
41380
CM92161OOOOAG
49670
1
CM94053OOOOAG
45940
CM94153OOOOAG
56930
1
70
DN3-400S
160 - 400
DN3-630S
250 - 630
CM94079OOOOAG
52590
CM94179OOOOAG
71560
1
320 - 800
CM96025OOOOAG
72930
CM96115OOOOAG
88980
1
400 - 1000
CM96026OOOOAG
100280
CM96116OOOOAG
134170
1
500 - 1250
CM96027OOOOAG
121200
CM96117OOOOAG
166920
1
DN4-1250S
In
400A
Std.
Pkg.
(Nos.)
M.R.P.
(`)
Per Unit
Type
Ir *
0.5
1.0
l
Inst
l
Conforms to IS/IEC 60947-2 & IEC 60947-2
Range: 40A to 1250A, 3P & 4P
Choice of 36kA / 50kA / 70kA breaking capacities
0.4
Ics = 100% Icu
Suitable for Isolation
Adjustable Over Load from 0.4 - 1.0 x In
DN3
Adjustable Short Circuit from 1.5 - 8 x Ir
MTX 2.0
Inbuilt Instantaneous Protection
Inbuilt ground fault protection from 20% - 50% of In
Adjustable neutral overload protection available : 50% to 150% of Ir
Provision of Thermal Memory : ON/OFF
Variable trip class at 7.2 Ir & 6 Ir
Front LED indication of Over Load (Ready, Over load pre-alarm & Overload)
Panel mounted display available for Current metering
Manual, Rotary or Motorised versions available @
For 3 phase 4 wire system, External neutral CTs available for 3P MCCBs
Wide Range of snap fit Internal and External Accessories
r
l
r
l
@ Motorised version available for DN2 and DN3 frames (please refer page No. 41)
Modules for MTX2.0 release
Cat. No.
M.R.P.
(`)
Per Unit
Current Metering Module
CM95698OOOO
#
Cable (2m length)
CM01196OOOO
1000
Power Supply Module
CL90722OOOO
10500
UNCO Module for Status
Indication & Control with
RS485 Port (for MTX1.0/2.0)
CL90852OOOO
9000
# Available on request
L&T, ESP 01.11.2013
MTX2.0 with current metering module
39
MCCB Range
Switch Disconnector - SD (MCCBs without protection release):
l
l
l
l
Used as switching devices for isolation
Range: 100A to 1250A, 3P & 4P
Suitable for isolation
Wide Range of snap fit Internal and External Accessories
PCC
DG
Transformer
MCCB-5 as Isolator
CB-1
CB-3
Type
4 Pole
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
100
CM96808OOKOOG
8200
CM96809OOKOOG
9830
1
125
CM96810OOLOOG
8400
CM96811OOLOOG
10300
1
160
CM96817OOMOOG
9640
CM96818OOMOOG
11710
1
200
CM96814OONOOG
12870
CM96815OONOOG
15480
1
250
CM96802OOPOOG
13210
CM96803OOPOOG
16390
1
320
CM96804OOQOOG
16960
CM96805OOQOOG
23200
1
400
CM96804OOROOG
18530
CM96805OOROOG
24230
1
500
CM96806OOSOOG
19980
CM96807OOSOOG
27110
1
630
CM96806OOTOOG
21180
CM96807OOTOOG
28680
1
800
CM93041OOUO
48980
CM93042OOUO
61730
1
1000
CM93041OOVO
61280
CM93042OOVO
79460
1
1250
CM93041OOAO
75790
CM93042OOAO
106130
1
DN3-400SD
DN3-630SD
DN4-1250SD
M.R.P.
(`)
Per Unit
CB-4
Std.
Pkg.
(Nos.)
Current
Rating
(A)
DN2-250SD
New
3 Pole
CB-2
MCC
MCCB-6 as Isolator
SCPD-1
SCPD-2
Starter-1
Starter-2
M
M
Representative Application Image
MCCBs for Motor back-up Protection:
MCCB
l
l
l
Range: 32A to 630A, 50kA
Suitable for isolation
Wide Range of snap fit Internal and External Accessories
Starter
Representative Application Image
M
Type
DN0-100M
Current
Rating
(A)
3 Pole
Breaking
Capacity Icu
at 415V. AC,
50Hz. (kA)
Cat. No.
Std.
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
Current
Rating
(A)
Std.
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
Cat. No.
32
CM98944OOEO
4600
1
100
CM92172OOKOOG
8250
1
40
CM98944OOFO
4600
1
125
CM92172OOLOOG
8475
1
50
CM98944OOGO
4600
1
160
CM92172OOMOOG
9920
1
CM98944OOHO
4600
1
200
CM92171OONOOG
12940
1
80
CM98944OOJO
4600
1
250
CM92171OOPOOG
16640
1
100
CM98944OOKO
4600
1
320
CM94516OOQOOG
19720
1
400
CM94516OOROOG
20885
1
500
CM94515OOSOOG
24615
1
630
CM94515OOTOOG
25030
1
63
50
Note: Please contact nearest branch office for fuseless type 2
co-ordination selection chart
40
Type
3 Pole
Breaking
Capacity Icu
at 415V. AC,
50Hz. (kA)
DN2-250M
DN3-400M
DN3-630M
50
L&T, ESP 01.11.2013
Automatic Source Transfer System
l
l
l
l
l
l
l
l
l
l
Stored Energy operated
Automatic / Manual control of power supply source
Set-up data programming
Virtual front panel viewing with key activation feature
Programmable I/Os
Test function
LED display
Voltage and Frequency display
Inbuilt UV protection
Inbuilt phase unbalance protection
New
AuXC-1000L
2
ASTS with Thermal - Magnetic Releases
Frame
3 Pole
4 Pole
M.R.P.
(`)
Per Unit
M.R.P.
(`)
Per Unit
108395
112995
114975
119275
250
127235
134875
100
111995
117655
160
120755
126135
Current
Rating
(A)
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
100
DN2
DN2
160
DN2
DN3
50
131975
142175
400
148745
160925
630
161225
177705
160
129375
137755
250
138095
151135
155985
164605
175285
193085
250
DN3
36
400
70
630
ASTS with Microprocessor Release MTX1.0
Frame
DN2
DN2
DN3
New
Type
Cat. No.
M.R.P.
(`)
Per Unit
Std. Pkg.
(Nos.)
AuXC-1000L
ST80024OOOO
39790
1
AuXC-1000
ST80230OOOO
47950
1
Can be used along with U-POWER Omega ACBs,
M.R.P.
(`)
Per Unit
M.R.P.
(`)
Per Unit
116135
123935
121135
132375
250
133715
147115
100
119955
127975
160
128535
138355
137735
152955
250
400
158465
174065
630
164845
186425
160
138695
152255
250
150875
161355
169785
190425
178905
201025
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
160
400
630
36
50
70
MCCBs, & MCX contactors
ASTS with Microprocessor Release MTX2.0
4 Pole
250
DN3
Auto Source Transfer Controller
3 Pole
Current
Rating
(A)
100
DN2
MCCBs + 2 SE-EOM + 2 UV + 1 MIL kit
Frame
Breaking
Capacity Icu
at 415V AC,
50Hz. (kA)
3 Pole
4 Pole
M.R.P.
(`)
Per Unit
M.R.P.
(`)
Per Unit
137075
144715
143955
156975
250
154475
169415
100
141655
149655
160
151155
162935
158215
176475
400
178245
195305
630
188345
214285
160
161995
177455
250
172435
189015
191585
213565
204885
242825
Current
Rating
(A)
100
DN2
DN2
DN3
DN2
DN3
160
400
630
36
50
70
ASTS MRP consists of the following products: 2 dsine MCCBs, 2 SE-EOMs, 2 UV release, 2 Aux + Trip Alarm contact, 1 MIL Kit & 1 AuXC-1000L Controller
For AuXC-1000 please add ` 8160 to the above MRP
Note: Picture shown is for representation purpose only, MCCB + EOM + UV combination, MIL kit & AuXC-1000L to be purchased separately & assembled at site.
L&T, ESP 01.11.2013
41
Accessories for
Auxiliary Contact
TAC
MCCBs
Shunt Release
UV Release
Internal
M.R.P. Std.
Pkg.
(`)
Cat. No.
Per Unit (Nos.)
Description
Auxiliary Contact
CM97886OOOO
DN0, DN1 - 1 C/O - Right
CM97887OOOO
DN0, DN1 - 2 C/O - Right
CM99801OOOO
DN2, DN3, DN4 - 1 C/O
CM99802OOOO
DN2, DN3, DN4 - 2 C/O
695
1180
790
1285
Direct Rotary Handle
Key Lock
Extended Rotary Handle
External
Description
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
Rotary Handle
1
DN0 Direct
CM97895OOOO
950
1
1
DN1 Direct
CM98040OOOO
1015
1
1
DN2 Direct
CM99829OOOO
1025
1
1
DN3 Direct
CM99860OOOO
1560
1
DN0 Extended
CM97896OOOO
1410
1
Trip Alarm Contact
DN0, DN1 - 1 C/O - Right
CM97888OOOO
695
1
DN1 Extended
CM98041OOOO
1450
1
DN0, DN1 - 2 C/O - Right
CM97889OOOO
1180
1
DN2 Extended
CM99830OOOO
1460
1
1
DN3 Extended
CM99861OOOO
2495
1
DN4 Extended
CM99884OOOO
3415
1
Type 1
CM99958TOOOO
1290
1
1
Type 2
CM99958TOOOA
1290
1
1
Type 3
CM99958TOOOB
1290
1
Type 12
CM99958TOOOC
1290
1
Type 23
CM99958TOOOD
1290
1
CM99803OOOO
DN2, DN3, DN4 - 1 C/O - Right
790
Auxiliary 1 C/O + TAC 1 C/O
DN0, DN1 - Right
CM97890OOOO
1180
1
DN2, DN3, DN4 - Right
CM99804OOOO
1445
1
Shunt Release
CM97883OMOO
DN0, DN1 - 240/415V AC - Left
990
DN2, DN3, DN4 -110/240/415V AC, 110/220V DC CM99805OOOO 1790@
Under Voltage Release
CM97892BOOO
DN0, DN1 - 240V AC - Left
1330
1
DN2, DN3 - 240V AC - Left
CM99986BOOO 2100**
1
DN4 - 240V AC - Left
CM99906OOOO 2305**
1
Panel door mounted Key lock for
Extended Rotary Handle #
# - Can be used with dsine, DU, DH/DL/DM, DTH new look extended ROM
@ - ‘NO’ of control contactor to be connected in series for DC control supply
** - Use these UV Cat. Nos. with Grey look MCCBs only
Stored Energy EOM
Neutral CT
Description
External
M.R.P.
Cat. No.
(`)
Per Unit
Std.
Pkg.
(Nos.)
DN3 - 240V AC $
MIL Kit - Base
Mounted
External
M.R.P.
Cat. No.
(`)
Per Unit
Description
Std.
Pkg.
(Nos.)
Spreader Terminals
Stored Energy Electrical Operating Mechanism
DN2 - 240V AC $
Spreader
Terminals
Adaptor kit for NCT
Price
on
CM98130OOOO request
CM98132OOOO
1
DN0-100 - 3 Pole
CM97785OOOO
195
Set of 6
1
DN1, DN2 - 250 - 3 Pole
ST98053OOOO
1035
Set of 6
DN3-400 - 3 Pole
ST98065OOOO
1945
Set of 6
External Neutral CT
DN2 - 40A
CM99946OOOO
1400
1
DN3-630 - 3 Pole
ST98054OOOO
2175
Set of 6
DN2 - 63A
CM99947OOOO
1400
1
DN4-800 - 3 Pole
ST90361OOOO
4150
Set of 6
New DN4-1000 - 3 Pole
CM90063OOVO
11000
Set of 6
15025 Set of 6
DN2 - 100A
CM99948OOOO
1400
1
DN2 - 160A
CM99949OOOO
2000
1
DN4-1250 - 3 Pole
ST98055OOOO
DN2 - 250A
CM99950OOOO
2000
1
DN0-100 - 4 Pole
CM97921OOOO
265
Set of 8
DN3 - 400A
CM99954OOOO
3700
1
DN1, DN2 - 250 - 4 Pole
CM92007OOOO
1260
Set of 8
DN3 - 630A
CM99955OOOO
3700
1
DN3-400 - 4 Pole
ST98066OOOO
2790
Set of 8
DN4 - 800A
CM99889OOOO
5500
1
DN3-630 - 4 Pole
CM92004OOOO
3275
Set of 8
DN4 - 1000A
CM99890OOOO
5500
1
DN4-800 - 4 Pole
ST90362OOOO
5405
Set of 8
New DN4-1000 - 4 Pole
CM90064OOVO
14300 Set of 8
DN4-1250 - 4 Pole
ST98058OOOO
19845 Set of 8
DN4 - 1250A
CM99891OOOO
5500
1
Adaptor kit for External Neutral CT
DN2-250
CM99994OOOO
450
Set of 2
Mechanical Interlock Kit - Base Mounted
DN3-400
CM99995OOOO
895
Set of 2
DN2-250
CM99731OOOO
3685
1
DN3-630
CM99997OOOO
950
Set of 2
DN3-400
CM99732OOOO
5715
1
DN4-800
CM99996OOOO
1600
Set of 2
DN3-630
CM99854OOOO
5715
1
DN4-1000/1250
CM99998OOOO
5950
Set of 2
- Including indicator Assembly (Aux + TAC)
$ - Please contact nearest branch office for availability
42
Note: Phase Barriers are supplied along with MCCBs
L&T, ESP 01.11.2013
C-POWER Air Circuit Breakers
C-POWER S1 Range of Air Circuit Breakers
l
l
l
l
l
l
l
l
l
l
l
l
Conforms to IS/IEC 60947-2 & IEC 60947-2
Current rating from 630A to 3200A
Available in 3 Pole/4 Pole, Manually & Electrically operated,
Fixed & Draw-out versions
High short time withstand capacity, Icu = Ics = Icw for 1 sec for
total selectivity
High mechanical and electrical operating life
100% rated neutral pole
Common height and depth across the range
Protection through Thermal - Magnetic (DN1) & Microprocessor
releases (SR18, SR18G & SR21i)
Self diagnostic Microprocessor based Releases with on-load testing
through TEST button
Inbuilt thermal memory
Protection Releases conform to EMI/EMC standards
Breaker control through MODBUS protocol
C-POWER S1 ACB
C-POWER Range of Air Circuit Breakers
l
l
l
l
l
l
l
l
l
C-POWER ACB
l
l
l
Conforms to IS/IEC 60947-2 & IEC 60947-2
Current rating from 800A to 6300A
Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed &
Draw-out versions
High short time fault withstanding capacity, Icu = Ics = Icw for 1 sec
for total selectivity
High mechanical and electrical operating life
100% rated neutral pole
Protection through Thermal - Magnetic (DN1) & Microprocessor
releases (SR18, SR18G, SR21i & SR71)
Self diagnostic Microprocessor based Releases with on-load testing
through TEST button
Inbuilt thermal memory
Protection Releases conform to EMI/EMC standards
Data communication & Power Management
Breaker control through MODBUS protocol
Breaking Capacities offered:
Icu = Ics = Icw for 1 sec
CN-CS : E
630A
800A
1000A
1250A
1600A
2000A
50kA
50kA
50kA
50kA
50kA
50kA
50kA
50kA
2500A
3200A
60kA
60kA
4000A
5000A
6300A
70kA
95kA
95kA
Frame-1
CN-CS : S1
50kA
50kA
50kA
50kA
Frame-2
Frame-1
CN-CS : C
50kA
50kA
50kA
50kA
55kA
60kA
CN-CS : H
65kA
65kA
65kA
65kA
75kA
75kA
CN-CS : H0
75kA
75kA
CN-CS : H/H1
100kA
100kA
Frame-1
Frame-2
Frame-3
Frame-4
For technical & dimension details please refer product catalogue.
44
L&T, ESP 01.11.2013
C-POWER Air Circuit Breakers
C-POWER S1 3 & 4 Pole Draw-out ACBs
Rating
630A
800A
1000A
1250A
1600A
2000A
Breaking
Capacity
Icu=Ics=Icw
(1 sec)
50kA
50kA
50kA
50kA
50kA
50kA
Thermal-Magnetic DN1
Microprocessor Based SR18G
3 Pole
Version
4 Pole
3 Pole
4 Pole
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
135440
SL96061
170870
168440
SL96071
203870
SL96042
135440
SL96062
EDO
SL96052
168440
MDO
SL96043
EDO
SL95331
M.R.P.
(`)
Per Unit
121440
SL95351
M.R.P.
(`)
Per Unit
156870
SL95341
154440
SL95361
189870
170870
SL95332
121440
SL95352
156870
SL96072
203870
SL95342
154440
SL95362
189870
141960
SL96063
181090
SL95333
127960
SL95353
167090
SL96053
174960
SL96073
214090
SL95343
160960
SL95363
200090
MDO
SL96044
158750
SL96064
204410
SL95334
144750
SL95354
190410
EDO
SL96054
191750
SL96074
237410
SL95344
177750
SL95364
223410
MDO
SL96045
179140
SL96065
224820
SL95335
165140
SL95355
210820
EDO
SL96055
212140
SL96075
257820
SL95345
198140
SL95365
243820
MDO
SL96046
215230
SL96066
269950
SL95336
201230
SL95356
255950
EDO
SL96056
248230
SL96076
302950
SL95346
234230
SL95366
288950
Cat. No.
M.R.P.
(`)
Per Unit
MDO
SL96041
EDO
SL96051
MDO
Cat. No.
C-POWER S1 3 & 4 Pole Fixed ACBs
Rating
630A
800A
Breaking
Capacity
Icu=Ics=Icw
(1 sec)
50kA
50kA
1000A
50kA
1250A
50kA
1600A
50kA
Thermal-Magnetic DN1
4 Pole
3 Pole
Microprocessor Based SR18G
4 Pole
3 Pole
Version
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
MF
SL95561
96820
SL95581
121030
SL95481
82820
SL95501
107030
EF
SL95571
129820
SL95591
154030
SL95491
115820
SL95511
140030
MF
SL95562
96820
SL95582
121030
SL95482
82820
SL95502
107030
EF
SL95572
129820
SL95592
154030
SL95492
115820
SL95512
140030
MF
SL95563
100920
SL95583
126150
SL95483
86920
SL95503
112150
EF
SL95573
133920
SL95593
159150
SL95493
119920
SL95513
145150
MF
SL95564
121740
SL95584
152180
SL95484
107740
SL95504
138180
EF
SL95574
154740
SL95594
185180
SL95494
140740
SL95514
171180
MF
SL95565
133780
SL95585
167230
SL95485
119780
SL95505
153230
EF
SL95575
166780
SL95595
200230
SL95495
152780
SL95515
186230
M.R.P. changes for
product customization w.r.t. SR18G ACB M.R.P.
M.R.P. (`)
Per Unit
23000
Bus - Coupler ( w/o protection)
Reduce
Microprocessor based SR18 (LSI )
Reduce
3000
Add
14000
Microprocessor based SR21i ( LSIG + ZSI )
C-POWER S1 Draw-Out ACBs will have inbuilt - 2NO+2NC Aux contact for MDO & 6NO+6NC Aux contact for EDO breakers, Safety shutter assembly,
Racking handle, Door sealing frame, Push-button cover & Rating error preventor.
C-POWER S1 Fixed ACBs will have inbuilt - 2NO+2NC Aux contact for MF & 6NO+6NC Aux contact for EF breakers, Door sealing frame & Push-button cover.
Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.
CN-CS…E Range 3 Pole Manual Fixed
Thermal-Magnetic Release Type DN1
Rating
Breaking
Capacity
Icu=Ics
=Icw (1 sec)
Version
Cat. No.
M.R.P.
(`)
Per Unit
400A
50kA
3P MF
SL93291OOOO
58580
630A
50kA
3P MF
SL93292OOOO
59100
800A
50kA
3P MF
SL93293OOOO
60830
1000A
50kA
3P MF
SL93294OOOA
62970
1250A
50kA
3P MF
SL93295OOOO
81720
1600A
50kA
3P MF
SL93296OOOO
91020
2000A
50kA
3P MF
SL93297OOOO
103450
L&T, ESP 01.11.2013
45
C-POWER Air Circuit Breakers
C-POWER 3 & 4 Pole Draw-out ACBs
Breaking
Capacity
Rating
Icu=Ics=Icw
(1 sec)
800A
1000A
1250A
1600A
2000A
2500A
3200A
4000A
65kA
65kA
65kA
65kA
55kA
60kA
75kA
70kA
75kA
Thermal-Magnetic DN1
Microprocessor Based SR18G
3 Pole
Version
4 Pole
3 Pole
4 Pole
MDO
SL95311
M.R.P.
(`)
Per Unit
177470
#
M.R.P.
(`)
Per Unit
226500
#
M.R.P.
(`)
Per Unit
163470
#
M.R.P.
(`)
Per Unit
212500
EDO
SL95321
210470
#
259500
#
196470
#
245500
MDO
SL95312
191800
#
240480
#
177800
#
226480
EDO
SL95322
224800
#
273480
#
210800
#
259480
MDO
SL95313
216730
#
263390
#
202730
#
249390
EDO
SL95323
249730
#
296390
#
235730
#
282390
MDO
SL95314
235700
#
295000
#
221700
#
281000
EDO
SL95324
268700
#
#
254700
#
314000
MDO
328000
ST35545
246760
ST35565
SL93065
232760
ST25035
293410
EDO
307410
ST35555
279760
ST35575
#
265760
#
326410
MDO
340410
ST35546
273230
ST35566
339510
SL93066
259230
ST25036
325510
ST35556
306230
ST35576
372510
#
292230
#
358510
ST35547
339280
ST35567
416010
SL93459
325280
SL93479
402010
ST35557
372280
ST35577
449010
#
358280
#
435010
#
*
#
*
#
*
#
*
#
*
#
*
#
*
#
*
ST35548
*
ST35568
*
SL93460
*
SL93480
*
ST35558
*
ST35578
*
#
*
#
*
Cat. No.
EDO
MDO (H0)
EDO (H0)
MDO (C)
EDO (C)
MDO (H0)
EDO (H0)
Cat. No.
Cat. No.
Cat. No.
5000A
95kA
MDO/EDO
#
*
#
#
*
#
*
6300A
95kA
MDO/EDO
*
#
*
#
*
#
*
#
*
Note: For higher breaking capacities & 690V AC application please contact the nearest branch office
C-POWER 3 & 4 Pole Manual Fixed ACBs
Rating
Breaking
Capacity
Icu=Ics=Icw
(1 sec)
Thermal-Magnetic DN1
4 Pole
3 Pole
Microprocessor Based SR18G
4 Pole
3 Pole
Version
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
800A
50kA
1000A
50kA
1250A
50kA
1600A
50kA
2000A
55kA
SL97635
160420
#
208090
SL93005
146420
#
194090
2500A
60kA
SL97636
176770
#
238300
SL93006
162770
#
224300
3200A
70kA
#
#
#
*
*
#
70kA
*
*
#
4000A
*
*
*
*
On Request
MF
On Request
#
#
#
Note: For higher breaking capacities & 690V AC application please contact the nearest branch office
M.R.P. changes for
product customization w.r.t. SR18G M.R.P.
Reduce
Bus-Coupler (w/o protection)
Microprocessor based SR18 (LSI)
Microprocessor based SR21i (LSIG + ZSI)
Microprocessor based SR71 (LSIGN + Current metering + Advance protection + PS Module)
M.R.P.
(`)
Per Unit
23000
Reduce
3000
Add
14000
Add
Communication Module (MODBUS) for SR71 release (SR71 - COM)
SL94698
Power Metering Module for SR71 release (SR71 - PM)
SL94699
On
Request
C-POWER Draw-Out ACBs will have inbuilt - 6NO+6NC Aux contact, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating
Error preventor. Option of horizontal & vertical termination upto 4000A also available.
EDO version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging.
C-POWER Fixed ACBs will have inbuilt - 6NO+6NC Aux contact, Door sealing frame & Push-button cover.
Note: 1 NO Aux contact in manual version & 2NO+2NC in electrical version breakers will be pre-wired with accessories mounted in breaker.
In electrically operated breaker with DN1 release, either earth fault or undervoltage protection can be used.
Note: Electrical Fixed type breakers are available on request.
# Available on "Made to order" basis.
46
* Available on request
L&T, ESP 01.11.2013
Accessories of C-POWER Air Circuit Breakers
Accessories (Common for C-POWER Family)
AN1 Module
LTPB
Description
LIP
M.R.P.
(`)
Per Unit
Cat. No.
Description
Cat. No.
M.R.P.
(`)
Per Unit
Shunt Release (SR)
Lockable Trip Push Button (LTPB)
Type AA
UV Release
Shunt Release
SL93148OOOA
2300
Type EA : 24/48V DC
SL92718O4OO
2300
SL92718O1OO
2300
Type BB
SL93148OOOB
2300
Type EA : 110V DC
Type CC
SL93148OOOC
2300
Type EA : 220V DC
SL92718O2OO
2300
Type DD
SL93148OOOD
2300
Type EA1 : 110V AC
SL92718OAOO
2300
Lockable Trip Push Button kit (3 I/C & 2 B/C)
SL91936OOOO
11530
Type EA1 : 240V AC
SL92718OBOO
2300
Lockable Trip Push Button kit (A to Z)
ST28895OOOO
59910
Type EA1 : 415V AC
SL92718ODOO
2300
Lockable Trip Push Button kit (A to P)
ST28730OOOO
36870
Under Voltage Release (UVR)
Locking of ACB in Isolated position (LIP)
Type MV : 24V DC
ST36877OOOO
3380
Type A
SL93146OOOA
2300
Type MV : 240V AC
SL92720BOOO
3380
Type B
SL93146OOOB
2300
Type MV : 415V AC
SL92720DOOO
3380
Type C
SL93146OOOC
2300
Earth Fault Release ( for DN1)
Type D
SL93146OOOD
2300
Type EF1 (10%, 20% In )
SL91340OOOO
2300
Type EF2 (30%, 40%, 50% In)
SL91341OOOO
2300
Type A
SL93147OOOA
2300
Type B
SL93147OOOB
2300
AN1 Remote Annunciation Module for
Type C
SL93147OOOC
2300
SR18/SR18G/SR21i : 240V AC
SL94654OOOO
7180
Type D
SL93147OOOD
2300
Microswitch for Voltmetric Releases (2) each
SL92703OOOO
1860
SL92704OOOO
1860
SL92705OOOO
3110
Locking of ACB in Any position (LAP)
Racking Interlock
Microswitch for Common Indication of O/L &
Type AA
SL93149OOOA
4330
S/C (3) each
Type BB
SL93149OOOB
4330
Microswitch for Separate Indication of O/L &
Type CC
SL93149OOOC
4330
S/C (3) each (for DN1 release)
Type DD
SL93149OOOD
4330
Service Position Microswitch - Right (2)
SL93142OOOO
1250
Service Position Microswitch - Left (2)
SL93143OOOO
1250
Test or Isolated Position Microswitch - Right (2)
SL93144OOOO
1250
Test or Isolated Position Microswitch - Left (2)
SL93145OOOO
1250
Door Interlock
SL93150OOOO
2300
Note :
a. The Numerical in brackets, against various accessories indicate the SICs
required for wiring purpose in Draw-Out breakers
b. Shunt release requires one set of auxiliary contacts
c. Maximum 24 SICs can be fitted on an ACB. In Electrical ACBs 5 SICs are
prewired for control circuit purpose
Vertical Terminal Adaptor
Description & Rating
Cat. No.
Qty
M.R.P.
(`)
Per Unit
Features
l
Vertical Terminal Adaptors for Draw out C-POWER ACB
l
630-1250 S1/800-1000 C
SL93281OOOO
1
3010
1600-2000 S1/1250-1600 C
SL93282OOOO
1
3520
2000 C
SL93284OOOO
1
4820
2500 C
SL93285OOOO
1
5230
3200H0/H1, 4000H0/H
SL93288OOOO
1
14060
L&T, ESP 01.11.2013
l
Remote Operation & Control of ACB
Communicates on MODBUS Protocol
Inbuilt RS485 Port
UN-CO module
Description
UN-CO module for Breaker control
Cat. No.
Qty
M.R.P.
(`)
Per Unit
CL90852OOOO
1
9000
47
Spares of C-POWER Air Circuit Breakers
Protection Releases
Description
M.R.P.
(`)
Per Unit
Cat. No.
Protection Releases
Available on Request
Microprocessor based Type SR71
SR71
Microprocessor based Type SR21i
SL93960OOOO
44000
Microprocessor based Type SR18G
SL93959OOOO
30000
Microprocessor based Type SR18
SL93958OOOO
27000
Thermal-Magnetic Release Type DN1
SL93152OOOO
16000
Test-Kit SRT-2 (SR21i/SR18G/SR18)
ST23130OOOO
31300
SR21i
Upgrade to high end
communicable Release SR71
Retrofit kit solutions are available
For further details please contact
the nearest branch office
SR18G
SR18
DN1
Test Kit
Description
Cat. No.
Qty.
M.R.P.
(`)
Per Unit
CTs for SR18/SR18G/SR21i
For retrofitting of
any ACB to
U-POWER
OMEGA
Please contact the nearest
branch office
630 S1 Fix & Draw-out
ST37495OOOO
1
3920
800 C/H/S1 Fix & Draw-out
SL01857OOOO
1
3920
1000 C/H/S1 Fix & Draw-out
SL01858OOOO
1
3920
1250 C/H/S1 Fix & Draw-out
SL90571OOOO
1
4760
1600 C/H/S1 Fix & Draw-out
SL90572OOOO
1
4760
2000 C/H Fix & Draw-out
SL90565OOOO
1
5100
2000 S1 Draw-out
SL93210OOOO
1
5100
SL90566OOOO
1
5100
2500 C/H Fix & Draw-out
2500 S1 Draw-out
3200 D Fix & Draw-out
SL90567OOOO
1
6170
3200 S1 Draw-out
SL90575OOOO
1
6170
3200 H0/H1
SL01740OOOO
1
6170
4000 C
SL90568OOOO
1
6980
4000 H0/H
SL01739OOOO
1
6980
For External Neutral C.T.s please use the above Cat. No.
48
L&T, ESP 01.11.2013
U-POWER Air Circuit Breakers
OMEGA
U-POWER Range of Air Circuit Breakers
OMEGA
l
l
l
l
l
l
l
l
l
l
l
Complete range conforms to IS/IEC 60947-2 & IEC 60947-2
Current rating from 400A to 6300A in 3 frames sizes
Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed/Draw-out version
Common Height & Depth across the range
High short time fault withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
High mechanical and electrical operating life
Neutral pole is 100% rated, option of 50% & 200% rated neutral also available
Available in both NRYB & RYBN configuration in 4 Pole ACBs
In-built Electrical & Mechanical Anti-Pumping
Modular & snap-fit accessories
Ease of on-site conversion from Fixed to Draw-out version
Matrix Protection & Control units:
l
l
l
l
l
l
l
l
l
l
l
l
l
Available in 8 versions - MTX1.0/1G/1.5G, MTX2.5/2.5G,
MTX3.5/3.5EC & MTX4.5
Unique O-LED display for metering
Touch screen technology in UW-MTX4.5
Unique with-drawable Communication & Power metering modules
Dual protection curve settings & Password protection
Soft-rating plug for precise protection at lower load currents
Provision for on-load self-diagnosis of Releases
Data communication on Modbus, Profibus & wireless Zigbee protocols
Power & Harmonics measurement
Temperature rise monitoring & protection
Easy to integrate with HMI & PLC
Add-on modules for advance protection
Protection Releases conform to EMI/EMC standard
UW-MTX1.0
UW-MTX1G
UW-MTX1.5G
UW-MTX4.5
UW-MTX2.5/2.5G
UW-MTX3.5/3.5EC
UW-MTX4.5
Breaking Capacities offered:
Icu = Ics = Icw for 1 sec
800A
1000A
1250A
1600A
2000A
2500A
3200A
4000A
5000A
6300A
UW3-40
UW3-50
UW3-63
Frame-1
S : 65kA
Frame-2
S : 65kA
Frame-3
N : 50kA
H : 80kA
H : 80kA
UW1-08 UW1-10 UW1-12 UW1-16 UW1-20 UW1-25
H : 80kA
UW2-08 UW2-10 UW2-12 UW2-16 UW2-20 UW2-25 UW2-32
V : 100kA
UW3-08 UW3-10 UW3-12 UW3-16 UW3-20 UW3-25 UW3-32
Note: 400A & 630A ACBs are also available on request.
L&T, ESP 01.11.2013
49
U-POWER Air Circuit Breakers
OMEGA
U-POWER ACB ordering information:
OMEGA
UW 1
08
N
X
D
1
2
9
0
0
OMEGA 800A Fr-1 50kA 3P EDO UW-MTX1.5G
(3)
Temperature Rise Monitoring
Not Required
0
Required
1
Selection for P&C Units
B/C (w/o protection)
0
UW - MTX1.0
7
Frame Size
UW - MTX1G
8
Frame - I
UW - MTX1.5G
9
1
1
Frame - II
2
UW - MTX2.5
Frame - III
3
UW -MTX2.5G
2
UW-MTX3.5
3
UW-MTX3.5EC
4
UW-MTX4.5
5
Current Ratings
400A
04
630A
06
800A
08
1000A
10
1250A
12
1600A
16
2000A
20
2500A (4)
25
3200A
32
4000A
40
5000A
50
6300A
63
Type
Manually Operated
1
Electrically Operated
2
(2)
Selection for control voltage
For Manually Operated
0
240V AC ECD & CR & 240V AC SR
1
240V AC ECD & CR & 24V DC SR
2
Version
(1)
Selection for Breaking Capacity (Icu=Ics)
50kA (Fr-I upto 1600A)
65kA (Fr-I & Fr-II)
N
S
80kA (Fr-l, Fr-II & Fr-III)
H
100kA (Fr-III)
V
Draw-out
D
Fixed
F
Selection for No. of Poles
3 Pole
X
4 Pole 100% N
F
4 Pole 50% N (in Fr-III only)
H
4 Pole 200% N (upto 2500A)
D
Please Note :
(1)
For Icw values please refer product catalogue
(2)
Other options of control voltage are available as accessory
(3)
Temperature protection is available in UW-MTX3.5/3.5EC/4.5
(4)
For Fr-1, 2500A selection, please contact the nearest branch office
U-POWER OMEGA ACBs are offered with following standard features :
Draw-out version : U-POWER Omega ACBs with UW-MTX release will have inbuiltCurrent Metering (MTX 1.5G/2.5/2.5G/3.5/3.5EC/4.5), Common Fault Indication microswitch, 4NO+4NC Aux. contacts, Smart-racking
shutter, Safety shutter assembly, Racking Handle, Door sealing frame, Pad-locking arrangement for ON/OFF button, Rating Error Preventer,
Arc shield (with frame 1N, 2S & 3H version)
A) For ratings upto 1600A, one side vertical terminal adaptors (Bottom).
B) For ratings 2000A & above, both side vertical terminal adaptors (Top & Bottom).
Fixed Version :
U-POWER Omega ACBs with UW-MTX release will have inbuiltCurrent Metering (MTX 1.5G/2.5/2.5G/3.5/3.5EC/4.5), Common Fault Indication microswitch, 4NO+4NC Aux. contacts, Door sealing frame &
Pad-locking arrangement for ON/OFF button.
Electrically operated ACB includes ECD (240V AC), CR (240V AC) & SR (240V AC or 24V DC).
50
L&T, ESP 01.11.2013
U-POWER Air Circuit Breakers
OMEGA
3 Pole ACBs with UW-MTX1.5G (LSING + Current Metering)
3 Pole Manual Draw-out ACB with UW-MTX1.5G
Current
Rating
N (50kA)
Version
S (65kA)
M.R.P.
(`)
Per Unit
Cat. No.
Cat. No.
H (80kA)
M.R.P.
(`)
Per Unit
Cat. No.
V (100kA)
M.R.P.
(`)
Per Unit
M.R.P.
(`)
Per Unit
Cat. No.
800A
UW108NXD01900
UW108SXD01900
UW108HXD01900
UW308VXD01900
1000A
UW110NXD01900
UW110SXD01900
UW110HXD01900
UW310VXD01900
1250A
UW112NXD01900
UW112SXD01900
UW112HXD01900
UW312VXD01900
1600A
UW116NXD01900
UW116HXD01900
UW316VXD01900
2000A
-
-
UW120SXD01900
UW120HXD01900
-
-
UW225SXD01900
UW225HXD01900
3200A
-
-
UW232SXD01900
UW232HXD01900
UW332VXD01900
4000A
-
-
-
-
UW340HXD01900
UW340VXD01900
5000A
-
-
-
-
UW350HXD01900
UW350VXD01900
6300A
-
-
-
-
UW363HXD01900
UW363VXD01900
2500A
MDO
On Request
UW116SXD01900
On Request
On Request
UW320VXD01900
UW325VXD01900
On Request
3 Pole Manual Fixed ACB with UW-MTX1.5G
Current
Rating
N (50kA)
Version
S (65kA)
M.R.P.
(`)
Per Unit
Cat. No.
Cat. No.
H (80kA)
M.R.P.
(`)
Per Unit
Cat. No.
V (100kA)
M.R.P.
(`)
Per Unit
Cat. No.
800A
UW108NXF01900
UW108SXF01900
UW108HXF01900
UW308VXF01900
1000A
UW110NXF01900
UW110SXF01900
UW110HXF01900
UW310VXF01900
1250A
UW112NXF01900
UW112SXF01900
UW112HXF01900
UW312VXF01900
1600A
UW116NXF01900
UW116HXF01900
UW316VXF01900
2000A
-
-
UW120SXF01900
UW120HXF01900
-
-
UW225SXF01900
UW225HXF01900
3200A
-
-
UW232SXF01900
UW232HXF01900
UW332VXF01900
4000A
-
-
-
-
UW340HXF01900
UW340VXF01900
5000A
-
-
-
-
UW350HXF01900
UW350VXF01900
6300A
-
-
-
-
UW363HXF01900
UW363VXF01900
2500A
MF
On Request
UW116SXF01900
On Request
M.R.P. changes for product customization
MDO to EDO or MF to EF conversion (Includes ECD 240V AC, CR 240V AC & SR 240V AC or 24V DC)
On Request
UW320VXF01900
UW325VXF01900
M.R.P.
(`)
Per Unit
On Request
M.R.P.
(`)
Per Unit
On Request
Protection & Control Unit change with respect to UW-MTX1.5G ACB M.R.P.
Buscoupler (without protection release)
UW - MTX1.0 (LSI - BCD Switches)
UW - MTX1G (LSING - BCD Switches)
UW-MTX3.5 (LSING + Current Metering) - can be upgraded for Power Metering & Communication
UW-MTX3.5EC (LSING + Power Metering + Communication)
On Request
UW-MTX4.5 (LSING + Power Metering + Communication with Touch Screen navigation + UW - PS Module)
UW-PS, Auxiliary power supply module for display in No-load or OFF condition
COM Module (MODBUS) for communication
PM Module for power metering
L&T, ESP 01.11.2013
51
U-POWER Air Circuit Breakers
OMEGA
4 Pole ACBs with UW-MTX1.5G (LSING + Current Metering)
4 Pole Manual Draw-out ACB with UW-MTX1.5G
Current
Rating Version
N (50kA)
S (65kA)
M.R.P.
(`)
Per Unit
Cat. No.
H (80kA)
M.R.P.
(`)
Per Unit
Cat. No.
V (100kA)
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
800A
UW108NFD01900
UW108SFD01900
UW108HFD01900
UW308VFD01900
1000A
UW110NFD01900
UW110SFD01900
UW110HFD01900
UW310VFD01900
1250A
UW112NFD01900
UW112SFD01900
UW112HFD01900
UW312VFD01900
1600A
UW116NFD01900
UW116HFD01900
UW316VFD01900
2000A
-
-
UW120SFD01900
UW120HFD01900
-
-
UW225SFD01900
UW225HFD01900
3200A
-
-
UW232SFD01900
UW232HFD01900
UW332VFD01900
4000A
-
-
-
-
UW340HFD01900
UW340VFD01900
5000A
-
-
-
-
UW350HFD01900
UW350VFD01900
6300A
-
-
-
-
UW363HFD01900
UW363VFD01900
2500A
MDO
On Request
UW116SFD01900
On Request
On Request
UW320VFD01900
UW325VFD01900
On Request
4 Pole Manual Fixed ACB with UW-MTX1.5G
Current
Rating Version
N (50kA)
S (65kA)
M.R.P.
(`)
Per Unit
Cat. No.
Cat. No.
H (80kA)
M.R.P.
(`)
Per Unit
V (100kA)
M.R.P.
(`)
Per Unit
Cat. No.
M.R.P.
(`)
Per Unit
Cat. No.
800A
UW108NFF01900
UW108SFF01900
UW108HFF01900
UW308VFF01900
1000A
UW110NFF01900
UW110SFF01900
UW110HFF01900
UW310VFF01900
1250A
UW112NFF01900
UW112SFF01900
UW112HFF01900
UW312VFF01900
1600A
UW116NFF01900
UW116HFF01900
UW316VFF01900
2000A
-
-
UW120SFF01900
UW120HFF01900
-
-
UW225SFF01900
UW225HFF01900
3200A
-
-
UW232SFF01900
UW232HFF01900
UW332VFF01900
4000A
-
-
-
-
UW340HFF01900
UW340VFF01900
5000A
-
-
-
-
UW350HFF01900
UW350VFF01900
6300A
-
-
-
-
UW363HFF01900
UW363VFF01900
2500A
MF
On Request
UW116SFF01900
On Request
On Request
UW320VFF01900
UW325VFF01900
On Request
Auto Source Transfer Controller
New AuXC-1000L
ST80024OOOO
M.R.P.
(`)
Per Unit
39790
AuXC-1000
ST80230OOOO
47950
Type
System for :
Complete monitoring of Power & Energy Parameters
Breaker Control
Cat. No.
Description
M.R.P.
(`)
Per Unit
BPV304ARH
Add on Powerman for 04 RS485 Meters/ACB/MCCB
28130
BPV308ARH
Add on Powerman for 08 RS485 Meters/ACB/MCCB
56260
BPV312ARH
Add on Powerman for 12 RS485 Meters/ACB/MCCB
84400
BPV316ARH
Add on Powerman for 16 RS485 Meters/ACB/MCCB
112530
Cat. No.
Can be used along with U-POWER Omega ACBs,
52
1
1
MCCBs, & MCX contactors
Features
l
l
The application price is valid only for L&T devices
For others please contact nearest branch office.
The application cost starts with minimum 24 devices, Cat. No. need to be
considered accordingly.
Integration cost and local product cost are not considered in above prices.
Std. Pkg. (Nos.)
l
Remote Operation & Control of ACB
Communicates on MODBUS Protocol
Inbuilt RS485 Port
UN-CO module
Description
Cat. No.
Qty
M.R.P.
(`)
Per Unit
UN-CO module for Breaker control
CL90852OOOO
1
9000
L&T, ESP 01.11.2013
Accessories of U-POWER Air Circuit Breakers
OMEGA
Operation Counter
Door Interlock
Description
Cat. No.
Closing Release
M.R.P.
(`)
Per Unit
UV Release
Shunt Release
Description
Cat. No.
Operation Counter
CL90983OOOO
Door Interlock
CL90978OOOO
24-30V DC
CL90362OOOO
Electrical Position Indication (EPI)
CL95826OOOO
110V AC / 110-125V DC
CL90360OOOO
Microswitch for Common Fault Indication (CFI)
CL90949OOOO
220V AC / 200V DC
CL90364OOOO
240V AC / 250V DC
CL90359OOOO
Microswitch for Ready To Close Indication (RTC) CL90953OOOO
Microswitch for Shunt Release
Electrical Charging Device (ECD)
On
Request
CL90947OOOO
Microswitch for Spring Charging Indication
ST42672OOOO
On
Request
CL90361OOOO
415V AC / 400V DC
CL90951OOOO
Microswitch for Undervoltage Release
M.R.P.
(`)
Per Unit
Closing Release (CR)
24-30V DC
CL908174OOO
110V AC & DC
CL90817AOOO
240V AC / 220 - 250V DC
CL90817BOOO
On
Request
CL90817DOOO
415V AC
Shunt Release (SR)
R-Lock
Description
C-Lock
Cat. No.
M.R.P.
(`)
Per Unit
Mechanical Interlock using Key & Lock
24-30V DC
CL90816O4OO
110V AC / 110V DC
CL90816OAOO
240V AC / 220 - 250V DC
CL90816OBOO
415V AC
CL90816ODOO
Under Voltage Release (UVR) with time delay (0-1-3-5 sec)
24-30V DC
CL908184OOO
110V AC
CL90818AOOO
R - Lock Type - 1
CL00659OOOO
240V AC (DG application)
ST42745OOOO
R - Lock Type - 2
CL00660OOOO
240V AC
CL90818BOOO
R - Lock Type - 3
CL00661OOOO
415V AC
CL90818DOOO
R - Lock Type - 12
CL00662OOOO
R - Lock Type - 23
CL00663OOOO
Locking arrangement for OFF button
with R - Lock (on breaker)
CL90815OOOO
Locking arrangement for ISO position
with R - Lock (on Cradle)
CL90865OOOO
Locking arrangement for ANY position
with R - Lock (on Cradle)
CL90927OOOO
C - Lock Type - S
CL00664OOOO
C - Lock Type - T
CL00665OOOO
C - Lock Type - ST
CL00666OOOO
C - Lock Type - SS
CL00667OOOO
C - Lock Type - TT
CL00668OOOO
Locking arrangement for OFF button
with C - Lock (on breaker)
CL90814OOOO
Locking arrangement for ISO position
for C - Lock (on Cradle)
CL90982OOOO
Locking arrangement for ANY position
with C - Lock (on Cradle)
CL90981OOOO
On
Request
On
Request
On
Request
NCT
Description
Cat. No.
M.R.P.
(`)
Per Unit
External Neutral CT for UW-MTX Releases
Frame-1, 2 & 3 400-800A
CL00717OOOO
Frame-1, 2 & 3 1000-1600A
CL00718OOOO
Frame-1 2000-2500A
CL00719OOOO
Frame-2 & 3 2000-3200A
Frame-3 4000A
Frame-3 5000-6300A
On
Request
CL00720OOOO
CL00721OOOO
Note: For Mechanical Interlock using Key & Lock please order combination
of Lock and Locking arrangement.
L&T, ESP 01.11.2013
53
Accessories of U-POWER Air Circuit Breakers
OMEGA
Fix ACBs Terminal Adaptors
Draw-out ACBs Terminal Adaptors
Description
Cat. No.
M.R.P.
(`)
Per Unit
Description
Terminal Adaptors for Draw-out Omega ACBs
Frame-1 400-2000A (Vertical / Horizontal)
Frame-1 2500A (Vertical)
Frame-2 400-3200A (Vertical / Horizontal)
Terminal Adaptors for Fixed Omega ACBs
CL60963OOOO
CL60964OOOO
Frame-3 400-4000A (Vertical / Horizontal) #
CL90747OOOO
Frame-3 5000A (Vertical) #
CL90748OOOO
Frame-3 6300A (Vertical) #
CL60965OOOO
M.R.P.
(`)
Per Unit
Cat. No.
Frame-1 400-1600A N/S (Vertical / Horizontal)
On
Request
# : Please consider 4 terminal adaptors per phase (I/C + O/G)
Frame-1 400-2000A H & 2000A S
CL60967OOOO
CL60968OOOO
(Vertical/Horizontal)
Frame-1 2500A S/H (Vertical)
CL60976OOOO
Frame-2 400-3200A S/H (Vertical / Horizontal)
CL60977OOOO
Frame-3 400-4000A H/V (Vertical / Horizontal) #
CL90668OOOO
Frame-3 5000A H/V (Vertical) #
CL60982OOOO
Frame-3 6300A H/V (Vertical) #
CL90669OOOO
On
Request
# : Please consider 4 terminal adaptors per phase (I/C + O/G)
Mechanical Interlock using Bowden Cable
Description
Cat. No.
MODBUS Module
M.R.P.
(`)
Per Unit
Description
Mechanical Interlock using Bowden Cable (3 meters length)
Between 2 Incomers
CL90659OOOO
Between 3 Incomers
CL90660OOOO
Between 2 Incomers & 1 Standby
CL90661OOOO
Between 2 Incomers & 1 Buscoupler
CL90662OOOO
On
Request
Mechanical Interlock using Bowden Cable (2 meters length)
Between 2 Incomers
CL90810OOOO
Between 3 Incomers
CL90811OOOO
Between 2 Incomers & 1 Standby
CL90812OOOO
Between 2 Incomers & 1 Buscoupler
CL90813OOOO
Note: Common from 400A to 6300A and can be interlocked between
Fixed / Draw-out / Mixed version
54
On
Request
Power Metering Module
Cat. No.
M.R.P.
(`)
Per Unit
Matrix Releases & Modules
UW-MTX1.0
CL91966OOOO
UW-MTX1G
CL91971OOOO
UW-MTX1.5G
CL91965OOOO
UW-MTX2.5
CL90112OOOO
UW-MTX2.5G
CL90610OOOO
UW-MTX3.5
CL90113OOOO
UW-MTX3.5EC
CL90700OOOO
UW-MTX4.5
CL90611OOOO
Power supply module (UW-PS)
CL90722OOOO
Relay Module
CL90716OOOO
MODBUS Module
CL90709OOOO
Profibus Module
CL90732OOOO
Power Metering Module
CL90704OOOO
ZSI Module (UW-ZSI)
CL90718OOOO
TCS module (UW-TCS)
CL90719OOOO
Simulation Kit
CL90724OOOO
On
Request
L&T, ESP 01.11.2013
Reactive Power Management Solutions
PF Compensation:
l Standard Duty Capacitors
l Heavy Duty Capacitors
l Ultra Heavy Duty Capacitors
Capacitor Switching:
l MO C Capacitor Duty Contactors
l Thyristor Switching Module
Control:
l etaCON - APFC Controller
Harmonic Mitigation:
l Detuned Reactors
5.67%, 7% and 14%
Branch Protection:
Solutions:
l
l
l
MCCB
MCB
Fuse
l
l
etaSYS - APFC Panels
Harmonic Mitigation Solutions
Reactive Power Management Solutions
Power Factor Correction Capacitors
Standard Duty Capacitors
l
l
l
l
l
7% Detuned Copper Reactors, 440 V 50 Hz
MPP standard duty capacitors
Operating losses - 0.45 W / kVAr
Over current withstand capability
- 1.5 times rated current
Inrush current withstand capability
- 200 times rated current
Number of switching
- 5000 operations per year
Duty
Type
kVAr
Rating
Voltage
(V)
M.R.P.
(`)
per kVAr
Standard
Duty
Cylindrical
1 to 25
440 V
186
1 to 50
440 V
254
Box
Heavy Duty Capacitors
l
l
l
l
l
l
Duty
Type
Cylindrical
(Gas filled)
MPP heavy duty capacitors
Operating losses - 0.35 W / kVAr
Over current withstand capability
- 1.8 times rated current
Inrush current withstand capability
- 300 times rated current
Operating life - 130000 hours
Number of switching
- 8000 operations per year
kVAr
Rating
3 to 15
20 & 25
20 to 30
Heavy Duty
Box
(Resin filled)
5 to 15
20 to 50
Voltage
(V)
M.R.P.
(`)
per kVAr
440 V
331
480 V
364
525 V
397
690 V
413
440 V
323
480 V
355
525 V
388
690 V
404
440 V
406
480 V
447
525 V
487
440 V
397
480 V
437
525 V
476
LTXL - Ultra Heavy Duty Capacitors
l
l
l
l
l
l
Duty
Advance APP technology
Lower operating losses - 0.35 W / kVAr
High over current withstand capability
- 3 times rated current
High inrush current withstand capability
- 500 times rated current
Higher operating life - 300000 hours
More number of switching
- 20000 operations per year
Type
kVAr
Rating
5 to 15
LTXL - Ultra
Heavy Duty
Box
20 to 100
Voltage
(V)
M.R.P.
(`)
per kVAr
440 V
652
480 V
717
525 V
782
690 V
815
440 V
640
480 V
704
525 V
768
690 V
800
Prices of 850 V and 1000 V LTXL capacitors are available on request
Copper wound reactors
Lower operating losses
High linearity - 1.8 times
the rated current
Thermal cut off
l
l
l
l
kVAr Rating
Cat. No.
M.R.P.
(`)
Per Unit
5
LTFR0705B2
7390
10
LTFR0710B2
11615
12.5
LTFR0712B2
12875
15
LTFR0715B2
14255
20
LTFR0720B2
16890
25
LTFR0725B2
17950
50
LTFR0750B2
28505
75
LTFR0775B2
42230
100
LTFR0700B2
58065
Note: Prices of 5.67% & 14% reactors are available on request
Selection of capacitors for detuned
harmonic filter application
Capacitor kVAr selection is done considering the tuning frequency of 189 Hz with
7% reactor and based on standard ratings available.
With 7% detuned reactor
Effective
kVAr
output Reactor (440 V)
Capacitor (480 V)
Capacitor (525 V)
5 kVAr
5 kVAr
7.5 kVAr 480 V
7.5 kVAr 525 V
10 kVAr
10 kVAr
12.5 kVAr 480 V
12.5 kVAr 525 V
12.5 kVAr
12.5 kVAr
15 kVAr 480 V
15 kVAr 525 V
15 kVAr
15 kVAr
20 kVAr 480 V
20 kVAr 525 V
20 kVAr
20 kVAr
25 kVAr 480 V
25 kVAr 525 V
25 kVAr
25 kVAr
30 kVAr 480 V
25 kVAr 525 V +
8.33kVAr 525 V
50 kVAr
50 kVAr
2 nos of 30 kVAr 480 V
2 nos of 25 kVAr 525 V +
8.33kVAr 525 V
75 kVAr
75 kVAr
3 nos of 30 kVAr 480 V
3 nos of 25 kVAr 525 V +
8.33kVAr 525 V
100 kVAr
100 kVAr
4 nos of 30 kVAr 480 V
4 nos of 25 kVAr 525 V +
8.33kVAr 525 V
Selection for 5.67% and 14% reactors available on request.
Sample Selection: for 25kVAr 7% detuned reactors with
heavy duty capcitors, place an order for: 1 No. 25 kVAr 7% detuned reactor:
LTFR0725B2 & 1 No. 30 kVAr LTCCN capacitors at 480 V: LTCCN330C2
C - Cylindrical, B - Box
Ordering
Information
for Capacitors
Duty : D/F - Standard**,
H - Heavy, N - Heavy Duty
Gas Filled, U - Ultra Heavy,
kVAr Rating
Sample ratings
01 - 1 kVAr
07 - 7.5 kVAr
10 - 10 kVAr
12 - 12.5 kVAr
00 - 100 kVAr
Voltages : A - 415V, B - 440V,
C - 480V, M - 525V,
W - 690V,
Y - 850V, Z - 1000V
#
Cat. Nos. L T
C
3
2
** F - 1 to 6 kVAr. D - 7.5 kVAr & above
Standard Rating Available are : 1, 2, 3, 4, 5, 6, 7.5, 8.33, 10, 12.5, 15, 20, 25, 30, 50, 100
56
L&T, ESP 01.11.2013
Reactive Power Management Solutions
Thyristor Switching Module, 440V 50Hz
l
l
l
Capacitor Duty Contactors - Type MO C
High Peak Inverse Voltage
(PIV) - 2.2 kV
Lower operating losses
Auto thermal cut off
kVAr Rating
Cat. No.
M.R.P.
(`)
Per Unit
10
LTTSM10B2
19760
25
LTTSM25B2
28190
50
LTTSM50B2
32900
MO C25
New
Voltage
CT
secondary input
Description
Model
Cat. No.
M.R.P.
(`)
Per Unit
9000
etaCON L3 3 stage APFC relay
5 Amp
415V
ERPML03D500
etaCON L5 5 stage APFC relay
5 Amp
415V
ERPML05D500 10000
etaCON L7 7 stage APFC relay
5 Amp
415V
ERPML07D500
etaCON L8 8 stage APFC relay
5 Amp
415V
ERPML08D500 13600
etaCON L12 12 stage APFC relay
5 Amp
415V
ERPML12D500 14800
Voltage
input
M.R.P.
(`)
Per Unit
Description
Model
RPM 14
Type
8.5
MO C8.5
12.5
APFC Relays
CT
secondary
Fourteen Stage 1 A or 5 A Field
APFC Relay
selectable
240V
Cat. No.
MO C50
kVAR Rating
@ 415V,
3Ph, 50Hz
MO C12.5
15
MO C15
20
MO C20
25
33.5
MO C25
MO C33.5
11000
50
MRPM1400000 16900
MO C50
70
MO C70
80
MO C80
MO C80
Cat. No.
M.R.P.
(`)
Per Unit
Std.
Pkg.
(Nos.)
1NO
CS96320
1740
1
1NC
CS96337
1740
1
1NO
CS96321
1955
1
Built-in
Auxiliary
Contacts
1NC
CS96338
1955
1
1NO
CS90019
2760
1
1NC
CS90020
2760
1
1NO
CS90021
3185
1
1NC
CS90022
3185
1
1NO
CS96322
3610
1
1
1NC
CS96339
3610
1NO
CS96323
6490
1
1NC
CS96340
6490
1
1NO
CS96324
9750
1
1NC
CS96341
9750
1
1NO
CS96325
11715
1
1NC
CS96342
11715
1
1NO
CS96326
12690
1
1NC
CS96343
12690
1
Please refer page No. 5 for further details.
etaPRO V2.0
Multi Utility Software Package
etaPRO is an innovative, multi-utility and user friendly software package, related to Reactive Power
Management. The users will get the benefit of easy and error free selection of products.
Salient Features :
•
•
•
•
•
Benefits :
kVAr calculation
Detuned harmonic filter selection
APFC panel Bill of Materials generation
Payback calculation
Technical articles and presentations
•
•
•
•
•
•
Easy selection of capacitors and reactors
Error free switchgear ratings selection
Time saving while preparing APFC quotations
Optimum step size selection
Automatic selection of capacitor-reactor combinations
BoM can be exported to Microsoft Excel format
To download the software for free visit www.LNTEBG.COM/etaPRO
L&T, ESP 01.11.2013
57
Reactive Power Management Solutions
etaSYS - STANDARD APFC PANELS
Product
kVAr Rating
Capacitors
Incomer
Branch Protection
Switching
etaSYS - MH
35 to 500 kVAr
Heavy Duty Gas filled capacitors
MCCB - up to 350 kVAr; ACB - 400 to 500 kVAr
MCCB
Auto + Manual
etaSYS - FH
35 to 500 kVAr
Heavy Duty Gas filled capacitors
MCCB - up to 350 kVAr; ACB - 400 to 500 kVAr
HRC Fuse
Auto + Manual
etaSYS - MU
100 to 500 kVAr
LTXL - Ultra Heavy Duty capacitors
MCCB - up to 350 kVAr; ACB - 400 to 500 kVAr
MCCB
Auto + Manual
etaSYS - FU
100 to 500 kVAr
LTXL - Ultra Heavy Duty capacitors
MCCB - up to 350 kVAr; ACB - 400 to 500 kVAr
HRC Fuse
Auto + Manual
etaSYS - MH1
etaSYS - FH1
Contactor switched standard APFC Panels
Panel
Rating
(kVAr)
Cat. No.
35
LTAPMH0351B2
50
LTAPMH0501B2
75
Contactor switched standard APFC Panels
No. of
Steps
M.R.P.
(`)
Per Unit
Panel
Rating
(kVAr)
Cat. No.
2x12.5 + 2x5
4
185000
35
LTAPFH0351B2
2 x 12.5 + 2x10 + 1x5
5
213700
50
LTAPFH0501B2
LTAPMH0751B2
2 x 25 + 2x10 + 1x5
5
250400
75
100
LTAPMH1001B2
50 + 25 + 15 + 5 + 5
5
286900
125
LTAPMH1251B2
2 x 12.5 + 2 x 25 + 50
5
150
LTAPMH1501B2
2 x 12.5 + 3 x 25 + 50
175
LTAPMH1751B2
200
No. of
Steps
M.R.P.
(`)
Per Unit
2x12.5 + 2x5
4
170100
2 x 12.5 + 2x10 + 1x5
5
206700
LTAPFH0751B2
2 x 25 + 2x10 + 1x5
5
245500
100
LTAPFH1001B2
50 + 25 + 15 + 5 + 5
5
270700
317000
125
LTAPFH1251B2
2 x 12.5 + 2 x 25 + 50
5
298400
6
355800
150
LTAPFH1501B2
2 x 12.5 + 3 x 25 + 50
6
344300
2 x 12.5 + 2 x 25 + 2 x 50
6
388000
175
LTAPFH1751B2
2 x 12.5 + 2 x 25 + 2 x 50
6
374500
LTAPMH2001B2
2 x 12.5 + 25 + 3 x 50
6
430400
200
LTAPFH2001B2
2 x 12.5 + 25 + 3 x 50
6
412800
225
LTAPMH2251B2
2 x 12.5 + 4 x 50
6
469800
225
LTAPFH2251B2
2 x 12.5 + 4 x 50
6
440900
250
LTAPMH2501B2
2 x 25 + 4 x 50
6
505800
250
LTAPFH2501B2
2 x 25 + 4 x 50
6
475800
275
LTAPMH2751B2
1x100 + 3x50 + 2x12.5
6
550700
275
LTAPFH2751B2
1x100 + 3x50 + 2x12.5
6
533700
300
LTAPMH3001B2
1x100 + 3x50 + 2x25
6
571700
300
LTAPFH3001B2
1x100 + 3x50 + 2x25
6
537000
350
LTAPMH3501B2
1x100 + 3x50 + 4x25
8
682500
350
LTAPFH3501B2
1x100 + 3x50 + 4x25
8
655600
400
LTAPMH4001B2
2x100 + 2x50 + 4x25
8
812500
400
LTAPFH4001B2
2x100 + 2x50 + 4x25
8
756900
450
LTAPMH4501B2
2x100 + 4x50 + 2x25
8
880000
450
LTAPFH4501B2
2x100 + 4x50 + 2x25
8
828800
500
LTAPMH5001B2
3x100 + 3x50 + 2x25
8
990900
500
LTAPFH5001B2
3x100 + 3x50 + 2x25
8
912100
No. of
Steps
M.R.P.
(`)
Per Unit
Step sizes (kVAr)
etaSYS - MH2
etaSYS - FH2
Contactor Switched standard APFC panels
with 7% detuned harmonics filter
Contactor Switched standard APFC panels
with 7% detuned harmonics filter
No. of
Steps
M.R.P.
(`)
Per Unit
Panel
Rating
(kVAr)
Cat. No.
50 + 25 + 15 + 5 + 5
5
405600
100
LTAPFH1002B2
50 + 25 + 15 + 5 + 5
5
396200
2 x 12.5 + 2 x 25 + 50
5
459200
125
LTAPFH1252B2
2 x 12.5 + 2 x 25 + 50
5
445200
LTAPMH1502B2
2 x 12.5 + 3 x 25 + 50
6
519500
150
LTAPFH1502B2
2 x 12.5 + 3 x 25 + 50
6
526100
175
LTAPMH1752B2
2 x 12.5 + 2 x 25 + 2 x 50
6
564100
175
LTAPFH1752B2
2 x 12.5 + 2 x 25 + 2 x 50
6
568900
200
LTAPMH2002B2
2 x 12.5 + 1 x 25 + 3 x 50
6
631800
200
LTAPFH2002B2
2 x 12.5 + 1 x 25 + 3 x 50
6
630800
225
LTAPMH2252B2
2 x 12.5 + 4 x 50
6
638400
225
LTAPFH2252B2
2 x 12.5 + 4 x 50
6
673100
250
LTAPMH2502B2
2 x 25 + 4 x 50
6
726000
250
LTAPFH2502B2
2 x 25 + 4 x 50
6
707000
275
LTAPMH2752B2
1x100 + 3x50 + 2x12.5
6
801800
275
LTAPFH2752B2
1 x 100 + 3 x 50 + 2 x12.5
6
764600
300
LTAPMH3002B2
1x100 + 3x50 + 2x25
6
842100
300
LTAPFH3002B2
1 x 100 + 3 x 50 + 2 x 25
6
798000
350
LTAPMH3502B2
1x100 + 3x50 + 4x25
8
1003400
350
LTAPFH3502B2
1 x 100 + 3 x 50 + 4 x 25
8
948300
400
LTAPMH4002B2
2x100 + 2x50 + 4x25
8
1153400
400
LTAPFH4002B2
2 x 100 + 2 x 50 + 4 x 25
8
1098600
450
LTAPMH4502B2
2x100 + 4x50 + 2x25
8
1257600
450
LTAPFH4502B2
2 x 100 + 4 x 50 + 2 x 25
8
1192100
500
LTAPMH5002B2
3x100 + 3x50 + 2x25
8
1403100
500
LTAPFH5002B2
3 x 100 + 3 x 50 + 2 x 25
8
1315100
Panel
Rating
(kVAr)
Cat. No.
100
LTAPMH1002B2
125
LTAPMH1252B2
150
Step sizes (kVAr)
Features of etaSYS:
l
l
l
l
IP 42 panels
Standard GA drawing readily available
Wide range of ratings (35 to 500 kVAr) covers the typical
requirement of APFC panel ratingsfor most of the industries
All the panels are with optimal number of steps and step sizes
- Offers sufficient step resolution which would be suitable for
all types of industries
- Panel operation without hunting of capacitors
l
l
Pre-selected switchgear with accurate ratings offers reliable
operation, protection and isolation
Accurate combination of capacitor and reactor offers better
protection against harmonics
Notes:
- Standard lead time of APFC panels is 6 to 8 weeks (Ex-Nagpur)
- Freight charges at actuals
- For other ratings and specifications, contact nearest branch office
58
Step sizes (kVAr)
Step sizes (kVAr)
etaSYS - FH3
Thyristor Switched standard APFC panels with 7%
detuned harmonics filter (Real-time PF Compensation)
Panel
Rating
(kVAr)
Cat. No.
100
LTAPFH1003B2
125
LTAPFH1253B2
150
No. of
Steps
M.R.P.
(`)
Per Unit
50 + 25 + 15 + 5 + 5
5
636500
2 x 12.5 + 2 x 25 + 50
5
709700
LTAPFH1503B2
2 x 12.5 + 3 x 25 + 50
6
824300
175
LTAPFH1753B2
2 x 12.5 + 2 x 25 + 2 x 50
6
871400
200
LTAPFH2003B2
2 x 12.5 +1 x 25 + 3 x 50
6
926000
225
LTAPFH2253B2
2 x 12.5 + 4 x 50
6
977200
250
LTAPFH2503B2
2 x 25 + 4 x 50
6
1011700
275
LTAPFH2753B2
1x100 + 3x50 + 2x12.5
6
1102500
300
LTAPFH3003B2
1x100 + 3x50 + 2x25
6
1134300
350
LTAPFH3503B2
1x100 + 3x50 + 4x25
8
1452500
400
LTAPFH4003B2
2x100 + 2x50 + 4x25
8
1595200
450
LTAPFH4503B2
2x100 + 4x50 + 2x25
8
1680600
500
LTAPFH5003B2
3x100 + 3x50 + 2x25
8
1844300
Step sizes (kVAr)
L&T, ESP 01.11.2013
Reactive Power Management Solutions
etaSYS - MU1
etaSYS - FU1
Contactor switched standard APFC Panels
Contactor switched standard APFC Panels
Panel
Rating
(kVAr)
Cat. No.
No. of
Steps
M.R.P.
(`)
Per Unit
Panel
Rating
(kVAr)
Cat. No.
100
LTAPMU1001B2
125
LTAPMU1251B2
50 + 25 + 15 + 5 + 5
5
345100
100
LTAPFU1001B2
50 + 25 + 15 + 5 + 5
5
331100
2 x 12.5 + 2 x 25 + 50
5
378800
125
LTAPFU1251B2
2 x 12.5 + 2 x 25 + 50
5
365100
150
175
LTAPMU1501B2
2 x 12.5 + 3 x 25 + 50
6
437900
150
LTAPFU1501B2
2 x 12.5 + 3 x 25 + 50
6
416900
LTAPMU1751B2
2 x 12.5 + 2 x 25 + 2 x 50
6
481500
175
LTAPFU1751B2
2 x 12.5 + 2 x 25 + 2 x 50
6
457200
200
LTAPMU2001B2
2 x 12.5 + 25 + 3 x 50
6
533200
200
LTAPFU2001B2
2 x 12.5 + 25 + 3 x 50
6
507800
225
LTAPMU2251B2
2 x 12.5 + 4 x 50
6
569100
225
LTAPFU2251B2
2 x 12.5 + 4 x 50
6
558900
250
LTAPMU2501B2
2 x 25 + 4 x 50
6
619100
250
LTAPFU2501B2
2 x 25 + 4 x 50
6
591800
275
LTAPMU2751B2
1x100 + 3x50 + 2x12.5
6
666600
275
LTAPFU2751B2
1x100 + 3x50 + 2x12.5
6
631500
300
LTAPMU3001B2
1x100 + 3x50 + 2x25
6
702600
300
LTAPFU3001B2
1x100 + 3x50 + 2x25
6
665500
350
LTAPMU3501B2
1x100 + 3x50 + 4x25
8
823400
350
LTAPFU3501B2
1x100 + 3x50 + 4x25
8
780200
400
LTAPMU4001B2
2x100 + 2x50 + 4x25
8
953500
400
LTAPFU4001B2
2x100 + 2x50 + 4x25
8
906700
450
LTAPMU4501B2
2x100 + 4x50 + 2x25
8
1041700
450
LTAPFU4501B2
2x100 + 4x50 + 2x25
8
990700
500
LTAPMU5001B2
3x100 + 3x50 + 2x25
8
1151800
500
LTAPFU5001B2
3x100 + 3x50 + 2x25
8
1113300
No. of
Steps
M.R.P.
(`)
Per Unit
Step sizes (kVAr)
Step sizes (kVAr)
etaSYS - MU2
etaSYS - FU2
Contactor Switched standard APFC panels
with 7% detuned harmonics filter
Contactor Switched standard APFC panels
with 7% detuned harmonics filter
Panel
Rating
(kVAr)
Cat. No.
100
LTAPMU1002B2
125
LTAPMU1252B2
150
No. of
Steps
M.R.P.
(`)
Per Unit
No. of
Steps
M.R.P.
(`)
Per Unit
Panel
Rating
(kVAr)
Cat. No.
50 + 25 + 15 + 5 + 5
5
477100
100
LTAPFU1002B2
50 + 25 + 15 + 5 + 5
5
456600
2 x 12.5 + 2 x 25 + 50
5
510700
125
LTAPFU1252B2
2 x 12.5 + 2 x 25 + 50
5
494300
LTAPMU1502B2
2 x 12.5 + 3 x 25 + 50
6
587300
150
LTAPFU1502B2
2 x 12.5 + 3 x 25 + 50
6
561300
175
LTAPMU1752B2
2 x 12.5 + 2 x 25 + 2 x 50
6
634200
175
LTAPFU1752B2
2 x 12.5 + 2 x 25 + 2 x 50
6
603200
200
LTAPMU2002B2
2 x 12.5 + 1 x 25 + 3 x 50
6
679500
200
LTAPFU2002B2
2 x 12.5 + 1 x 25 + 3 x 50
6
668000
225
LTAPMU2252B2
2 x 12.5 + 4 x 50
6
718600
225
LTAPFU2252B2
2 x 12.5 + 4 x 50
6
701600
250
LTAPMU2502B2
2 x 25 + 4 x 50
6
766700
250
LTAPFU2502B2
2 x 25 + 4 x 50
6
739600
275
LTAPMU2752B2
1x100 + 3x50 + 2x12.5
6
812200
275
LTAPFU2752B2
1x100 + 3x50 + 2x12.5
6
776100
300
LTAPMU3002B2
1x100 + 3x50 + 2x25
6
847200
300
LTAPFU3002B2
1x100 + 3x50 + 2x25
6
810100
350
LTAPMU3502B2
1x100 + 3x50 + 4x25
8
1016200
350
LTAPFU3502B2
1x100 + 3x50 + 4x25
8
972900
400
LTAPMU4002B2
2x100 + 2x50 + 4x25
8
1146200
400
LTAPFU4002B2
2x100 + 2x50 + 4x25
8
1103000
450
LTAPMU4502B2
2x100 + 4x50 + 2x25
8
1236100
450
LTAPFU4502B2
2x100 + 4x50 + 2x25
8
1193100
500
LTAPMU5002B2
3x100 + 3x50 + 2x25
8
1344500
500
LTAPFU5002B2
3x100 + 3x50 + 2x25
8
1309300
Step sizes (kVAr)
Step sizes (kVAr)
etaSYS - FU3
Thyristor Switched standard APFC panels with 7%
detuned harmonics filter (Real-time PF Compensation)
L&T, ESP 01.11.2013
Panel
Rating
(kVAr)
Cat. No.
100
LTAPFU1003B2
125
LTAPFU1253B2
150
No. of
Steps
M.R.P.
(`)
Per Unit
50 + 25 + 15 + 5 + 5
5
691400
2 x 12.5 + 2 x 25 + 50
5
771700
LTAPFU1503B2
2 x 12.5 + 3 x 25 + 50
6
906800
175
LTAPFU1753B2
2 x 12.5 + 2 x 25 + 2 x 50
6
959500
200
LTAPFU2003B2
2 x 12.5 +1 x 25 + 3 x 50
6
1031500
225
LTAPFU2253B2
2 x 12.5 + 4 x 50
6
1083000
250
LTAPFU2503B2
2 x 25 + 4 x 50
6
1125900
275
LTAPFU2753B2
1x100 + 3x50 + 2x12.5
6
1221200
300
LTAPFU3003B2
1x100 + 3x50 + 2x25
6
1263600
350
LTAPFU3503B2
1x100 + 3x50 + 4x25
8
1604700
400
LTAPFU4003B2
2x100 + 2x50 + 4x25
8
1758200
450
LTAPFU4503B2
2x100 + 4x50 + 2x25
8
1871600
500
LTAPFU5003B2
3x100 + 3x50 + 2x25
8
2058200
Step sizes (kVAr)
59
Digital Protective Relays
Single Pole Over Current or
Earth Fault Relay
3 Phase Over Current + Earth Fault Relay
C.T. Rating 1A or 5A, Field Selectable
C.T. Rating 1A or 5A, Not Field Selectable
IDMT and Definite time characteristics
Model
Aux.
Supply
(V)
Output
Contacts
Cat. No.
4 NO
Programmable
IDMT and Definite time characteristics
M.R.P. Std
Pkg.
(`)
Per Unit (Nos.)
MC31AAXX000 15000
1
2 NO + 2 NC
MC31A 20 - 110V AC/DC Pre programmed* MC31AAXX001 15000
1
MC31A 20 - 110V AC/DC
4 NO
Programmable
MC31ABXX000 15000
1
2 NO + 2 NC
MC31A 88 - 264V AC/DC Pre programmed* MC31ABXX001 15000
1
MC31A 88 - 264V AC/DC
* 2NO + 2NC contacts are factory programmed for both
Over current and Earth fault
Model
Aux.
Supply
(V)
C.T.
Secondary
(A)
Cat. No.
M.R.P.
(`)
Per Unit
Std
Pkg.
(Nos.)
MC12A
20 - 110V AC/DC
1A
MC12AA10X00
9600
1
MC12A
20 - 110V AC/DC
5A
MC12AA50X00
9600
1
MC12A 88 - 264V AC/DC
1A
MC12AB10X00
9600
1
MC12A 88 - 264V AC/DC
5A
MC12AB50X00
9600
1
Reverse Power Relay
C.T. Rating 1A or 5A, Not Field Selectable
3 Phase Over Current + Earth Fault Relay
With High Set
C.T. Rating 1A or 5A, Field Selectable
IDMT and Definite time characteristics
Model
Aux.
Supply
(V)
Output
Contacts
4 NO
Programmable
Cat. No.
M.R.P. Std
Pkg.
(`)
Per Unit (Nos.)
Aux
Supply
(V)
Cat. No.
MRP11 20 - 110V AC/DC
1A
MRP11A10X00
21500
1
MRP11 20 - 110V AC/DC
5A
MRP11A50X00
21500
1
MRP11 88 - 264V AC/DC
1A
MRP11B10X00
21500
1
MRP11 88 - 264V AC/DC
5A
MRP11B50X00
21500
1
MC61AAXX000 17000
1
2 NO + 2 NC
MC61A 20 - 110V AC/DC Pre programmed* MC61AAXX001 17000
1
Instantaneous Earth Fault Relay
MC61ABXX000 17000
1
C.T. Rating 1A or 5A, Not Field Selectable
2 NO + 2 NC
MC61A 88 - 264V AC/DC Pre programmed* MC61ABXX001 17000
1
MC61A 20 - 110V AC/DC
MC61A 88 - 264V AC/DC
4 NO
Programmable
High Impedance relay.
Meant for Restricted Earth fault protection of
Transformers/Generators or Differential
Protection of Generators.
* 2NO + 2NC contacts are factory programmed for both
Over current and Earth fault
3 Phase Over Current + Earth Fault Relay
with High Set & RS- 485
C.T. Rating 1A or 5A, Not Field Selectable
IDMT and Definite time characteristics
Model
Aux.
Supply
(V)
C.T.
Secondary
(A)
Std
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
C.T.
Secondary
(A)
Model
Model
C.T.
Secondary
(A)
Range
Cat. No.
Std
M.R.P.
Pkg.
(`)
Per Unit (Nos.)
SC14S
1
10 - 40 %
MC14SX10100
8400
1
SC14S
1
20 - 80 %
MC14SX10200
8400
1
SC14S
5
10 - 40 %
MC14SX50100
8400
1
SC14S
5
20 - 80 %
MC14SX50200
8400
1
G
Cat. No.
MC61C 20 - 110V AC/DC
In
1
On
1
MC61CA11000 *
MC61C 20 - 110V AC/DC
5
5
MC61CA55000 *
MC61C 88 - 264V AC/DC
1
1
MC61CB11000 *
MC61C 88 - 264V AC/DC
5
5
MC61CB55000 *
M.R.P.
Output
(`)
contacts
Per Unit
40000
5 NO; Pre40000
Programmed
40000
Contacts
40000
SC14S
Rs
SC14S
Rs
SC14S
Rs
Rs
SC14S
SC14S
Rs
Differential Protection
Restricted Earth Fault Protection
* - availabe on request only
Configuration of preprogrammed output contacts:
R1 - Time delayed output; R2 - Instantaneous output
R3 - Breaker opening; R4 - Breaker closing; R5 - Internal Relay Failure
L&T, ESP 01.11.2013
61
Digital Protective Relays
Comprehensive Motor protection relay
MM30-743
Mini Motor Protection Relay
with current based protections
• Inbuilt CT’s (1 Amp to 88 Amp)
• Selectable trip class - 10A, 10, 20 and 30 as per IEC 947-4-1
• Trip Indication
• Test Facility
• Protections:
- Thermal Overload
- Single Phasing
- Current Unbalance
- Phase sequence reversal
- Locked Rotor
- Earth Fault
- Under current
New
Model
Thermal
O/L Range
(A)
Aux. supply
Cat. No.
M.R.P.
(`)
Per Unit
MPR300
1 - 2.75
240V AC
MPR300BE010
5700
MPR300
2 - 5.5
240V AC
MPR301BE020
5700
MPR300
4 - 11
240V AC
MPR302BE040
5700
MPR300
8 - 22
240V AC
MPR303BE080
5700
MPR300
16 - 44
240V AC
MPR304BE160
5700
MPR300
32 - 88
240V AC
MPR305BE320
5700
MPR300
1 - 2.75
110V AC
MPR300BB010
5700
MPR300
2 - 5.5
110V AC
MPR301BB020
5700
MPR300
4 - 11
110V AC
MPR302BB040
5700
MPR300
8 - 22
110V AC
MPR303BB080
5700
MPR300
16 - 44
110V AC
MPR304BB160
5700
MPR300
32 - 88
110V AC
MPR305BB320
5700
Model
Aux. Supply
MM30 - 743 20 - 110V AC/ DC
Device
code
Cat. No.
M.R.P.
(`)
Per Unit
37,46,47,48,
EMM30AXX00E
69800
EMM30BXX00E
69800
49,50/51,51LR,
MM30 - 743 88 - 240V AC/ DC
64, 66,68,74
Comprehensive Motor protection relay
MM30-W74*
with current and voltage based protections
Model
Aux. Supply
Device
code
Cat. No.
M.R.P.
(`)
Per Unit
MM30 - W74 20 - 110V AC/ DC 12/14,27/59,37, EMM30WAX002 86500
46,47,48,49,
50/51, 51LR,55,
MM30 - W74 88 - 240V AC/ DC
EMM30WBX002 86500
64,66,68,74,81.
* available on request only
MPR300 - Trip Time Characteristics
Trip time delay
Trip
class
I = 120% of Im
I = 150% of Im
I = 720% of Im
10A
> 2 hours
2 min
2 - 10 secs
10
> 2 hours
4 min
4 - 10 secs
20
> 2 hours
6 min
6 - 20 secs
30
> 2 hours
12 min
9 - 30 secs
Im - Motor Full Load Current
I - Actual current drawn by the Motor
Note:
1. MRP300 must sense Line Current of Motor.
2. In case of reversible starter; place MPR300 before
Main Contactor.
62
L&T, ESP 01.11.2013
Intelligent Motor Protection & Control Relay - MCOMP*
Current Module (CM) Unit
R
New
Y
B
M COMP
CM UNIT
R
Y
B
M
Model
Aux. supply
Cat. No.
M.R.P.
(`)
Per Unit
MCOMP Blind unit Modbus RTU
80 - 240V AC/ DC
MCOMPZX90032
24000
MCOMP Blind unit Profibus
35000
MCOMPZX90033
80 - 240V AC/ DC
Model
Cable
Length
Current
rating (A)
Cat. No.
M.R.P.
(`)
Per Unit
MCOMP CT1 UNIT
0.5 M
0.675 to 2.025
MCOMPZX90006
4000
MCOMP CT2 UNIT
0.5 M
1.8 to 5.4
MCOMPZX90007
5000
MCOMP CT3 UNIT
0.5 M
4.5 to 13.5
MCOMPZX90008
5000
MCOMP CT4 UNIT
0.5 M
12.6 to 37.8
MCOMPZX90009
5000
MCOMP CT5 UNIT
0.5 M
36 to 81
MCOMPZX90010
6000
CT unit consists of 3 CT's for R, Y and B phase.
Cable length of 1 meter is available on request.
CM unit with extra crimped cable for CBCT
Y
B
M COMP
CM UNIT
CBCT
R
S1
Crimped
Cables
S2
R
Y
B
M
Model
Cable
Length
USB
Display Unit
1 meter
USB
Display Unit
Aux. supply
M.R.P.
(`)
Per Unit
Cat.No.
15000
80 - 240V AC/ DC MCOMPZX90042
15000
80 - 240V AC/ DC MCOMPZX90043
2 meter
Cable length of 0.5 meter is available on request
Model
Cable
Length
Current
rating (A)
Cat. No.
M.R.P.
(`)
Per Unit
MCOMP CT1 UNIT
1M
0.675 to 2.025
MCOMPZX90016
4000
MCOMP CT2 UNIT
1M
1.8 to 5.4
MCOMPZX90017
5000
MCOMP CT3 UNIT
1M
4.5 to 13.5
MCOMPZX90018
5000
MCOMP CT4 UNIT
1M
12.6 to 37.8
MCOMPZX90019
5000
MCOMP CT5 UNIT
1M
36 to 81
MCOMPZX90020
6000
CT unit consists of 3 CT's for R, Y and B phase.
Pair of crimped cable is provided for connecting external CBCT
* available on request only
Typical Wiring Diagram
R
Y
B
N
R
Y
B
N
For Motors With FLC ≤ 81 Amps
For Motors With FLC > 81 Amps
With External CT’s
SFU/MCCB
SFU/MCCB
Fuse
Fuse
L/+
L/+
N/-
N/1 2
4
R
N/- L/+
Aux. Volt
5
Reset
61 DI1
82
62 DI2
83
63 DI3
64 DI4
65 DI5
66 DI6
67
M COMP
CM Unit
B
COM
M COMP
Blind Unit
6
5
3
Stop
81
86 Contactor Coil
85
92
82
83
67
R
87
Trip Indication
91
Y
M COMP
USB Display unit
71 72
N/- L/+
Aux.Volt
61 DI1
64 DI4
66 DI6
84
88
4
3-Ph.Voltage
62 DI2
63 DI3
65 DI5
89
3
N B Y R
Start 1
Reset
90
CBCT
Y
1
4
Start 1
Stop
R
Contactor
CM Unit
B
CBCT
3
2
71 72
COM
M COMP
Blind Unit
Digital Output Contacts
3
Y
3-Ph. Voltage
Digital Output Contacts
1
6
Digital Inputs
Contactor
4
Digital Inputs
2
N B
1
2
81
86
Contactor Coil
84
85
89
87
88
92
90
M COMP
ALARM/PICK UP
R
Y
S2
B
M
RTD/PTC
L&T, ESP 01.11.2013
TRIP
ALARM/PICK UP
TRIP
RTD/
PTC
Analog
OP
53 56 51 54
RS 485
RST
ENT
S1
L
N
R
D+ D-
Modbus RS 485 Looping
4-20mA Output
To Field Ammeter
M COMP
PWR/COMM
MOTOR/STATUS
PWR/COMM
MOTOR/STATUS
S1
USB Display unit
Trip indication
91
Y
S2
B
M
RTD/PTC
Analog
OP
53 56 51 54
RST
ENT
L
N
RS 485
D+ D-
Modbus RS 485 Looping
4-20mA Output
To field Ammeter
RTD/PTC
63
Digital Protective Relays
APFC Relays
Single Phase Under Voltage or
Over Voltage Relay
New
Model
Voltage
CT
secondary input
Description
Cat. No.
M.R.P.
(`)
Per Unit
9000
etaCON L3 3 stage APFC relay
5 Amp
415V
ERPML03D500
etaCON L5 5 stage APFC relay
5 Amp
415V
ERPML05D500 10000
etaCON L7 7 stage APFC relay
5 Amp
415V
ERPML07D500
etaCON L8 8 stage APFC relay
5 Amp
415V
ERPML08D500 13600
etaCON L12 12 stage APFC relay
5 Amp
415V
ERPML12D500 14800
Description
Model
RPM 14
CT
secondary
Fourteen Stage 1 A or 5 A Field
APFC Relay
selectable
Voltage
input
240V
Cat. No.
Generator
Grounding
MG30I Solid
grounding
MG30I
MG30
MG30
Solid
grounding
Aux.
supply
Device code
Cat. No.
M.R.P.
(`)
Per Unit
20 - 110 21,24,27/59,32,37, EM30GIAXX00 210000
VAC/ DC 40,46,49,50/27,
88 - 240 50V/51V, 51BF,
EM30GIBXX00 210000
VAC/DC 60FL, 64S,68,81
20 - 110V AC/DC
MV12AA00X00
10000
1
MV12A
88 - 264V AC/DC
MV12AB00X00
10000
1
Three phase Voltage and Frequency relay
with df/dt and dv/dt protection
Model
Aux.
supply
Device code
Cat. No.
M.R.P.
(`)
Per Unit
UFD34
20 - 110V
AC/ DC
27, 59, 81, df/dt, dv/dt
EFD34A00000
123000
UFD34
88 - 240V
AC/DC
27, 59, 81, df/dt, dv/dt
EFD34B00000
123000
20 - 110V
AC/ DC
50/51, 68,
87, 87N
ED32GAXX000 * 266500
Generator
Differential
Relay
88 - 240V
AC/DC
50/51, 68,
87, 87N
ED32GBXX000 * 266500
Cat. No.
Model
Aux.
supply
Device code
Cat. No.
M.R.P.
(`)
Per Unit
UM30
20 - 110V
AC/ DC
24, 27d/59d, 47, 59,
59Uo, 78, 81
EUM30A00000 *
123000
UM30
88 - 240V
AC/DC
24, 27d/59d, 47, 59,
59Uo, 78, 81
EUM30B00000 *
123000
* available on request only
M.R.P.
(`)
Per Unit
Generator
MD32G Differential
Relay
64
MV12A
Voltage Frequency and Zero Sequence
Voltage Relay with Vector shift detection
Device
code
MD32G
Std
Pkg.
(Nos.)
MRPM1400000 16900
Impedance
20 - 110
Grounding
EMG30AXX000 210000
VAC/ DC 21,24,27/59,32,37,
(NGR/ NGT)
40,46,49,50/27,
50V/51V,51BF,
Impedance
88 - 240 60FL, 64S,68,81
Grounding
EMG30BXX000 210000
VAC/DC
(NGR/ NGT)
Description
M.R.P.
(`)
Per Unit
M.R.P.
(`)
Per Unit
Aux.
supply
Model
Cat. No.
11000
Generator protection relay
Model
Aux.
Supply
(V)
Model
L&T, ESP 01.11.2013
Electronic Metering Devices
Single Phase kWh meter
with LCD display
3 Phase 4 Wire kWh meter
Counter type
Model EM101+ Class 1 Base mounting
Model EM301B Class 1 Base mounting
Cat. No.
M.R.P.
(`)
Per Unit
1Ph LCD Meter 5-30A without optical port
WM101BC5DL0
1640
1Ph LCD Meter 10-60A without optical port
WM101BC7DL0
1950
1P LCD Meter 5-30A with optical port
WM101BC5DDH
1Ph LCD Meter 10-60A with optical port
WM101BC7DDH
Description
Cat. No.
M.R.P.
(`)
Per Unit
3Ph 4 W kWh CT op base mtg 240V 1-2A
WM301BC1C00
4820
3Ph 4 W kWh CT op base mtg 240V 5 -10 A
WM301BC3C00
4310
1950
3Ph 4 W kWh Dir base mtg 240V 5 -20 A Sleek
WM301BC4D20
4310
2050
3Ph 4 W kWh Dir base mtg 240V 10 -40 A Sleek
WM301BC6D20
4310
3Ph 4 W kWh Dir base mtg 240V 10 - 60 A big body WM301BC7D10
4410
3Ph 4 W kWh Dir base mtg 240V 50 -100 A big body WM301BC8D10
6250
Description
Trivector Meter Class 1 whole current meter
Trivector Meter Class 0.5
Model ER300P Class 1 (Base Mounting)
Model ER300P Class 0.5 (Base Mounting)
Cat. No.
M.R.P.
(`)
Per Unit
WR300BC7300
6660
3Ph, 4W TVM 240 V 10 - 60A BM RS 485 * WR300BC73RS
9500
Description
3Ph, 4W TVM 240 V 10 - 60A BM
Cat. No.
M.R.P.
(`)
Per Unit
3Ph, 3W TVM 110V ( L-L) 1 A Class 0.5 BM *
WR200BB1200
20500
3Ph, 3W TVM 110V ( L-L) 5 A Class 0.5 BM *
WR200BB5200
20500
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.5 BM
WR300BB1200
20500
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.5 BM
WR300BB5200
20500
3Ph, 4W TVM 240V ( L-N) 1 A Class 0.5 BM *
WR300BC1200
20500
3Ph, 4W TVM 240V ( L-N) 5 A Class 0.5 BM
WR300BC5200
20500
3Ph, 3W TVM 110V ( L-L) 1 A Class 0.5 BM RS485 * WR200BB12RS
24600
3Ph, 3W TVM 110V ( L-L) 5 A Class 0.5 BM RS485 * WR200BB52RS
24600
WR300BB12RS
24600
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.5 BM RS485 * WR300BB52RS
24600
3Ph, 4W TVM 240V ( L-N) 1 A Cl 0.5 BM RS485 *
WR300BC12RS
24600
3Ph, 4W TVM 240V ( L-N) 5 A Cl 0.5 BM RS485
WR300BC52RS
24600
Description
* - available on request only
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.5 BM RS485
Trivector Meter Class 0.2
Model ER300P Class 0.2 (Base Mounting)
* - available on request only
Meter reading instrument
Cat. No.
M.R.P.
(`)
Per Unit
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.2 BM
WR300BB1100
46120
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.2 BM
WR300BB5100
46120
3Ph, 4W TVM 110V ( L-L) 1 A Class 0.2 BM RS485 WR300BB11RS
49200
3Ph, 4W TVM 110V ( L-L) 5 A Class 0.2 BM RS485 WR300BB51RS
49200
Description
L&T, ESP 01.11.2013
Description
METER READING INSTRUMENT - (6MB)
Cat. No.
M.R.P.
(`)
Per Unit
990MRIXX00S
100000
65
Electronic Metering Devices
3 Ph Flush Mounting Multifunction meter
Model NOVA - LCD display
Nova
3 Ph Flush Mounting kWH meter
Model ACRUX - counter type
Acrux
Description
Cat. No.
M.R.P.
(`)
Per Unit
Description
Cat. No.
M.R.P.
(`)
Per Unit
3Ph 4 W 240V 5A with RS485
WM30KFC3CRS
(MFM - LCD display with RS 485 port) - NOVA
4600
3Ph 4 W 240V 1A
(kWh meter counter type) - Acrux
WM301FC1C10
3200
3Ph 4W 240V 5A
(MFM - LCD display)
4300
3Ph 4 W 240V 5A
(kWh meter counter type) - Acrux
WM301FC3C10
3200
WM30KFC3C00
Intelligent Panel Meter
3 Ph Flush Mounting Dual source kWH meter
Model QUASAR Class 1 (Flush Mounting) 96 x 96 mm
Model GEMINI - LCD display
Gemini
Cat. No.
M.R.P.
(`)
Per Unit
3Ph, 4W IPM 240 V (L-N) 1 A Class 1 FM *
WI300FC1300
8710
3Ph, 4W IPM 240 V (L-N) 5 A Class 1 FM
WI300FC5300
8710
3Ph, 3W IPM 110 V (L-L) 1 A Class 1 FM *
WI301FC1300
8710
3Ph, 3W IPM 110 V (L-L) 5 A Class 1 FM *
WI301FC5300
8710
3Ph, 4W IPM 110 V (L-L) 1A Class 1 FM *
WI300FB1300
8710
3Ph, 4W IPM 110 V (L-L) 5A Class 1 FM *
WI300FB5300
8710
3Ph, 4W IPM 240 V (L-N) 1 A Class 1 FM
with RS485 *
WI300FC13RS
9740
3Ph, 4W IPM 240 V (L-N) 5 A Class 1 FM
with RS485
WI300FC53RS
9740
3Ph, 3W IPM 110 V (L-L) 1 A Class 1 FM
with RS485 *
WI301FC13RS
9740
3Ph, 3W IPM 110 V (L-L) 5 A Class 1 FM
with RS485 *
WI301FC53RS
9740
3Ph, 4W IPM 110 V (L-L) 1A Class 1 FM
with RS485 *
WI300FB13RS
9740
3PH, 4W IPM 110 V (L-L) 5A Class 1 FM
with RS485 *
WI300FB53RS
9740
Description
* - available on request only
Description
3Ph 4 W 240V 5A with RS485
(Dual source kWh meter) - Gemini
Cat. No.
M.R.P.
(`)
Per Unit
WM30DFC3CRS
4600
Intelligent Panel Meter
Model QUASAR plus Class 0.5 (Flush Mounting) 96 x 96 mm
Description
Cat. No.
M.R.P.
(`)
Per Unit
3Ph, 4W IPM 240 V (L-N) 1 A Class 0.5 FM *
WI300FC1200
10760
3Ph, 4W IPM 240 V (L-N) 5 A Class 0.5 FM
WI300FC5200
10760
3Ph, 3W IPM 110 V (L-L) 1 A Class 0.5 FM *
WI301FC1200
10760
3Ph, 3W IPM 110 V (L-L) 5 A Class 0.5 FM *
WI301FC5200
10760
3Ph, 4W IPM 110 V (L-L) 1A Class 0.5 FM *
WI300FB1200
10760
3Ph, 4W IPM 110 V (L-L) 5A Class 0.5 FM *
WI300FB5200
10760
3Ph, 4W IPM 240 V (L-N) 1 A Class 0.5 FM with RS485
WI300FC12RS
11790
3Ph, 4W IPM 240 V (L-N) 5 A Class 0.5 FM with RS485
WI300FC52RS
11790
3Ph, 3W IPM 110 V (L-L) 1 A Class 0.5 FM with RS485
WI301FC12RS
11790
3Ph, 3W IPM 110 V (L-L) 5 A Class 0.5 FM with RS485
WI301FC52RS
11790
3Ph, 4W IPM 110 V (L-L) 1A Class 0.5 FM with RS485 * WI300FB12RS
11790
3Ph, 4W IPM 110 V (L-L) 5A Class 0.5 FM with RS485 * WI300FB52RS
11790
* - available on request only
66
L&T, ESP 01.11.2013
Electronic Metering Devices
VEGA series
VEGA series
Multifunction meters Class 1.0
Single function meters
New
AMMETER
VOLTMETER
Cat. No.
M.R.P.
(`)
Per Unit
3Ph Multifunction Meter, Model A, class 1, 5A
WDM303FDWA1
6990
1Ph Voltmeter Class 1
WDS101FEV00
1000
3Ph Multifunction Meter, Model B, class 1, 5A
WDM303FDNB1
10900
1Ph Ammeter, Class 1, 5A
WDS101FCA00
1000
3Ph Multifunction Meter, Model C, class 1, 5A
WDM303FDNC1
16020
1Ph Ammeter, Class 1, 1A
WDS101OCA00
1000
3Ph Multifunction Meter, Model A, class 1, 1A
WDM303ODWA1
6990
1Ph Freq. meter Class 0.2
WDS121FCF00
1000
3Ph Multifunction Meter, Model B, class 1, 1A
WDM303ODNB1
10900
3Ph Multifunction Meter, Model C, class 1, 1A
WDM303ODNC1
16020
3Ph Voltmeter Class 1
WDS301FEV00
1360
3Ph Multifunction Meter, Model A, class 1, 5A with Relay WDM303FDWA0
8200
3Ph Ammeter, 5A, Class 1
WDS301FCA00
1360
3Ph Multifunction Meter, Model B, class 1, 5A with Relay WDM303FDNB0
13320
3 Ph Ammeter, 1 A, Class 1
WDS301OCA00
1360
3Ph Multifunction Meter, Model C, class 1, 5A with Relay WDM303FDNC0
20500
Description
Single Phase Basic Meters
Three Phase Basic Meters
VEGA Series
Description
VEGA Series
Cat. No.
M.R.P.
(`)
Per Unit
New
Multifunction meters Class 0.5
New
VAF Meter
Cat. No.
M.R.P.
(`)
Per Unit
3Ph Multifunction Meter, Model A, class 0.5* WDM313CDWA1
9000
3Ph VAF, Class 1, 5A
WDV303FC000
2600
3Ph Multifunction Meter, Model B, class 0.5* WDM313CDNB1
14000
3Ph VAF, Class 1, 1A
WDV303OC000
2600
3Ph Multifunction Meter, Model C, class 0.5* WDM313CDNC1
20000
Description
VAF Meter
Description
Cat. No.
M.R.P.
(`)
Per Unit
* Site selectable 1A/ 5A
Panel Meter Overview
Meter type
mi ENERGY
Din rail meters
New
Description
Cat. No.
M.R.P.
(`)
Per Unit
W2DLD050600
2200
3Ph 10-60A, 240V, Class 2 Din rail meter W4DLD100600
5000
1Ph 5-30A, 240V, Class 2 Din rail meter
Parametres
Display
RS 485
Accrux
kWh
Counter
No
Vega VAF
V, A, F, RPM
LED
No
Nova
V, A, F, Pf, kW, kWH
LCD
Optional
Gemini
V, A, F, kW, kWh - Dual source
LCD
Yes
Quasar
V, A, F, pf, Power, Energy, THD
LCD
Optional
Vega Model A
V, A, F, pf, Power, Energy, Run &
ON hours, RPM
LED
Yes
Vega Model B
V, A, F, pf, Power, Energy, Run &
ON hours, RPM + Neutral current,
LED
MD (kW & kVA), MD reset
Yes
Vega Model C
V, A, F, pf, Power, Energy,
Run & ON hours, RPM +
Neutral current, MD (kW & kVA),
MD reset + THD, Bi - directional
LED
Yes
# RPM = Rotations per minute
L&T, ESP 01.11.2013
67
Programmable Logic Controller (PLC)
l
l
l
l
l
Compact & Powerful
LX7S from 10 to 48 I/O
LX7 from 28 to 104 I/O
2 serial ports (with Modbus RTU)
Built-in backup flash memory
LX7S Series
(Non Expandable
PLC)
l
l
l
Built-in High speed counter & Pulse Output
Built-in real time clock in LX7
Ideal for small to mid size machine automation / AMF panels / Load
management / pump control and many more applications
Can communicate with ACB, MCCB Releases, Energy Meters
LX70
LX7 / LX7S
Type
l
LX700
M.R.P.
(`)
Per Unit
Description
Cat. No.
9500
LX7S-10ADR
AC Powered, 6 Digital Inputs, 4 Digital Outputs (Relay)
LX7S-10ADT
AC Powered, 6 Digital Inputs, 4 Digital Outputs (Transistor)
LX7S-14ADR
AC Powered, 8 Digital Inputs, 6 Digital Outputs (Relay)
11200
9300
LX7S-14ADT
AC Powered, 8 Digital Inputs, 6 Digital Outputs (Transistor)
10900
LX7S-20ADR
AC Powered, 12 Digital Inputs, 8 Digital Outputs (Relay)
13700
LX7S-20ADT
AC Powered, 12 Digital Inputs, 8 Digital Outputs (Transistor)
13300
LX7S-28ADR
AC Powered, 16 Digital Inputs, 12 Digital Outputs (Relay)
16500
LX7S-28ADT
AC Powered, 16 Digital Inputs, 12 Digital Outputs (Transistor)
16100
LX7S-40ADR
AC Powered, 24 Digital Inputs, 16 Digital Outputs (Relay)
20700
LX7S-40ADT
AC Powered, 24 Digital Inputs, 16 Digital Outputs (Transistor)
20100
LX7S-48ADR
AC Powered, 28 Digital Inputs, 20 Digital Outputs (Relay)
22900
LX7S-48ADT
AC Powered, 28 Digital Inputs, 20 Digital Outputs (Transistor)
22200
LX7S-10DDR
DC Powered, 6 Digital Inputs, 4 Digital Outputs (Relay)
LX7S-10DDT
DC Powered, 6 Digital Inputs, 4 Digital Outputs (Transistor)
LX7S-14DDR
DC Powered, 8 Digital Inputs, 6 Digital Outputs (Relay)
11200
LX7S-14DDT
DC Powered, 8 Digital Inputs, 6 Digital Outputs (Transistor)
10900
9500
9300
Base Modules
LX7 Series
(Expandable
PLC)
LX7-28ADR
AC Powered, 16 Digital Inputs, 12 Digital Outputs (Relay)
21252
LX7-28ADT
AC Powered, 16 Digital Inputs, 12 Digital Outputs (Transistor)
20066
LX7-48ADR
AC Powered, 28 Digital Inputs, 20 Digital Outputs (Relay)
31510
LX7-48ADT
AC Powered, 28 Digital Inputs, 20 Digital Outputs (Transistor)
29298
LX7-28DDR
DC Powered, 16 Digital Inputs, 12 Digital Outputs (Relay)
21922
LX7-28DDT
DC Powered, 16 Digital Inputs, 12 Digital Outputs (Transistor)
20608
LX7-48DDR
DC Powered, 28 Digital Inputs, 20 Digital Outputs (Relay)
33270
LX7-48DDT
DC Powered, 28 Digital Inputs, 20 Digital Outputs (Transistor)
30722
LX7-20ADR-4A
AC Powered, 12 Digital Inputs, 8 Digital Outputs (Relay), 4 Analog Inputs
24900
LX7-20ADR-6A
AC Powered, 12 Digital Inputs, 8 Digital Outputs (Relay), 4 Analog Inputs, 2 Analog Outputs
29500
LX7-20ADT-4A
AC Powered, 12 Digital Inputs, 8 Digital Outputs (Transistor), 4 Analog Inputs
24400
LX7-20ADT-6A
AC Powered, 12 Digital Inputs, 8 Digital Outputs (Transistor), 4 Analog Inputs, 2 Analog Outputs
28800
Expansion Modules
LX7-14EDR
Expansion Module, 8 Digital Inputs, 6 Digital Outputs (Relay)
10400
LX7-14EDT
Expansion Module, 8 Digital Inputs, 6 Digital Outputs (Transistor)
10100
LX7-28EDR
Expansion Module, 16 Digital Inputs, 12 Digital Outputs (Relay)
14300
LX7-28EDT
Expansion Module, 16 Digital Inputs, 12 Digital Outputs (Transistor)
13900
LX 70 Series PLC:
l Modular structure with variety of I/O modules
l Fast & powerful processors to control upto 384 I/O points
l Built-in PID for process control
68
LX 700 Series PLC:
l Modular structure with high density I/O modules
l Fast & powerful processors to control upto 1600 I/O points
l Distributed I/O configuration using Remote I/O master & slave
L&T, ESP 01.11.2013
Human Machine Interface (HMI)
l
l
l
l
l
Available from 3” to 15” in 8 models
Touch LCD interface
Modbus Serial, Ethernet, Field bus Communication
Supports various Fonts and Graphics
Supports various languages - Japanese, Korean etc
l
l
l
Multiple PLCs, Controllers connectivity. Communication with ACB,
MCCB, Energy Meter
Advanced features: Multy - Language, Graphic, Extended Alarms,
Recipe, Data Logging, Printing, Password protection, Trends
Supports scripting
M.R.P.
(`)
Per Unit
Type
Cat. No.
1
LX-TEXTMATE
DC Powered, 3”, 8-Line Alphanumeric Text Display
10400
2
S04TDAA
4.3" Wide 65536 Color TFT, SRAM, 480X272, 6M Memory(Serial only), DC powered
20000
3
E05TDAA
5.7" 65536 Color TFT, SRAM, 320X240, (Serial/USB/CF/Ethernet), DC powered
50000
4
S07TDAA
7" Wide 65536 Color TFT, SRAM, 800X480, 26M Memory (Serial only), DC powered
29000
5
E08TDAA
8.4" 65536 Color TFT, SRAM, 640*480, (Serial/USB/CF/Ethernet), DC powered
65000
6
E10TDWA
10.4" 65536 Color TFT, SRAM, 800x600, (Serial/USB/CF/Ethernet), DC powered
7
F12TAAA
12.1" 65536 Color TFT, SRAM, 800x600, (Serial/USB/CF/Ethernet, Option: Profibus slave), AC powered
150000
8
F15TAAA
15" 65536 Color TFT, SRAM, 1024x768, (Serial/USB/CF/Ethernet, Option: Profibus slave), AC powered
200000
L&T, ESP 01.11.2013
Description
58000
69
EXPERIENCE
We Go the Extra Mile
If you are looking for dependable protection for home,
workplace or complex, ask for Exora – L&T's new 10 kA
Modular Devices.
We give you the assurance of dependability that only a
leader can offer. We give you access through India's most
widely dispersed network.
We go the extra mile – with Exora.
MCBs | RCCBs | Isolators | Distribution Boards
Other Protection & Control Devices
Clarity/DP/112012
A New Level of Dependability
10kA Modular Devices from L&T
Miniature Circuit Breaker (MCB)
Range Highlights
l
True contact indication for individual pole
l
l
Label holder facility for all configurations
l
l
Conforms to IS/IEC 60898
l
Breaking capacity of 10kA throughout the range
l
No Line-Load bias
l
Available in B, C & D curves
l
Suitable for accessory fitment
Low watt loss - almost 50% of the values prescribed by
IS/IEC 60898
l
Suitable for DC application, as per IEC 60947-2
l
Current
Rating
(In)
Modules
1 Mod = 17.5mm
Trip free mechanism
Design based on advanced current limiting hammer trip
mechanism
- Rated Voltage:130V DC (for SP), 250V DC (for DP)
with breaking capacity of 6kA
B-Curve
Cat. No.
M.R.P.
(`)
Per Unit
C-Curve
Cat. No.
M.R.P.
(`)
Per Unit
D-Curve
Cat. No.
M.R.P.
(`)
Per Unit
Single Pole (SP)
0.5A
1
-
-
BB10E50C
300
BB10E50D
300
1A
1
-
-
BB10010C
300
BB10010D
300
2A
1
-
-
BB10020C
300
BB10020D
300
3A
1
-
-
BB10030C
300
BB10030D
300
4A
1
-
-
BB10040C
300
BB10040D
300
6A
1
BB10060B
204
BB10060C
204
BB10060D
265
10A
1
BB10100B
204
BB10100C
204
BB10100D
265
16A
1
BB10160B
204
BB10160C
204
BB10160D
265
20A
1
BB10200B
204
BB10200C
204
BB10200D
265
25A
1
BB10250B
204
BB10250C
204
BB10250D
265
32A
1
BB10320B
204
BB10320C
204
BB10320D
265
40A
1
BB10400B
480
BB10400C
480
BB10400D
495
50A
1
BB10500B
480
BB10500C
480
*
495
63A
1
BB10630B
480
BB10630C
480
*
495
0.5A
2
-
-
BB20E50C
800
BB20E50D
815
1A
2
-
-
BB20010C
800
BB20010D
815
BB20020C
800
BB20020D
815
-
BB20030C
800
BB20030D
815
Double Pole (DP)
2A
2
3A
2
-
-
4A
2
-
-
BB20040C
800
BB20040D
815
6A
2
BB20060B
620
BB20060C
620
BB20060D
665
10A
2
BB20100B
620
BB20100C
620
BB20100D
665
16A
2
BB20160B
620
BB20160C
620
BB20160D
665
20A
2
BB20200B
620
BB20200C
620
BB20200D
665
25A
2
BB20250B
620
BB20250C
620
BB20250D
665
32A
2
BB20320B
620
BB20320C
620
BB20320D
665
40A
2
BB20400B
1060
BB20400C
1060
BB20400D
1025
50A
2
BB20500B
1060
BB20500C
1060
*
1025
63A
2
BB20630B
1060
BB20630C
1060
*
1025
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
* Contact nearest L&T branch office for its availability.
L&T, ESP 01.11.2013
71
Miniature Circuit Breaker (MCB)
Current
Rating
(In)
Modules
1 Mod = 17.5mm
B-Curve
Cat. No.
M.R.P.
(`)
Per Unit
C-Curve
Cat. No.
M.R.P.
(`)
Per Unit
D-Curve
Cat. No.
M.R.P.
(`)
Per Unit
Three Pole (TP)
0.5A
3
-
-
BB30E50C
1100
BB30E50D
1120
1A
3
-
-
BB30010C
1100
BB30010D
1120
2A
3
-
-
BB30020C
1100
BB30020D
1120
3A
3
-
-
BB30030C
1100
BB30030D
1120
4A
3
-
-
BB30040C
1100
BB30040D
1120
6A
3
BB30060B
1000
BB30060C
1000
BB30060D
1020
10A
3
BB30100B
1000
BB30100C
1000
BB30100D
1020
16A
3
BB30160B
1000
BB30160C
1000
BB30160D
1020
20A
3
BB30200B
1000
BB30200C
1000
BB30200D
1020
25A
3
BB30250B
1000
BB30250C
1000
BB30250D
1020
32A
3
BB30320B
1000
BB30320C
1000
BB30320D
1020
40A
3
BB30400B
1550
BB30400C
1550
BB30400D
1570
50A
3
BB30500B
1550
BB30500C
1550
*
1570
63A
3
BB30630B
1550
BB30630C
1550
*
1570
Four Pole (FP)
0.5A
4
-
-
BB40E50C
1580
BB40E50D
1590
1A
4
-
-
BB40010C
1580
BB40010D
1590
2A
4
-
-
BB40020C
1580
BB40020D
1590
3A
4
-
-
BB40030C
1580
BB40030D
1590
4A
4
-
-
BB40040C
1580
BB40040D
1590
6A
4
BB40060B
1360
BB40060C
1360
BB40060D
1390
10A
4
BB40100B
1360
BB40100C
1360
BB40100D
1390
16A
4
BB40160B
1360
BB40160C
1360
BB40160D
1390
20A
4
BB40200B
1360
BB40200C
1360
BB40200D
1390
25A
4
BB40250B
1360
BB40250C
1360
BB40250D
1390
32A
4
BB40320B
1360
BB40320C
1360
BB40320D
1390
40A
4
BB40400B
1990
BB40400C
1990
BB40400D
2005
50A
4
BB40500B
1990
BB40500C
1990
*
2005
63A
4
BB40630B
1990
BB40630C
1990
*
2005
Note: Standard Pack Quantity for MCB : SP - 12 Nos., DP - 6 Nos., TP- 4 Nos., FP - 3 Nos.
* Contact nearest L&T branch office for its availability.
Auxiliary & Accessories for 10kA MCB
Description
Cat. No.
M.R.P.
(`)
Per Unit
Auxiliary Contact - 6A (1NO+1NC), 0.5 Mod
BZA11006
600
Shunt Release - 240V AC, 1 Mod
BZS00240
1595
Undervoltage Release - 240V AC, 1 Mod
BZU00240*
1390
* Contact nearest L&T branch office for its availability.
72
L&T, ESP 01.11.2013
Residual Current Circuit Breaker (RCCB)
Range Highlights
l Conforms to IS 12640 (Part 1) / IEC 61008-1
l RCCBs are available in DP and FP versions from 25 to 100A ratings with 30 mA, 100 mA and 300 mA sensitivity
l Truly current operated - operation even at nominal voltage
l Operates on Core Balance Current Transformer (CBCT) principle
l Operation even in case of neutral failure
l Advanced neutral mechanism
Current
Rating
(In)
Modules
1 Mod = 17.5 mm
Cat. Nos.
M.R.P.
(`)
Per Unit
30 mA
2
BG202503
2300
100 mA
2
BG202510
2340
300 mA
2
BG202530
30 mA
2
100 mA
2
300 mA
Sensitivity
Double Pole (DP)
25A
40A
63A
100A
Current
Rating
(In)
Sensitivity
Modules
1 Mod = 17.5 mm
Cat. Nos.
M.R.P.
(`)
Per Unit
Four Pole (FP)
30 mA
4
BG402503
2910
100 mA
4
BG402510
2935
2340
300 mA
4
BG402530
2935
BG204003
2585
30 mA
4
BG404003
3035
BG204010
2600
100 mA
4
BG404010
2950
2
BG204030
2600
300 mA
4
BG404030
2950
30 mA
2
BG206303
3245
30 mA
4
BG406303
3420
100 mA
2
BG206310
3290
100 mA
4
BG406310
3395
300 mA
2
BG206330
3290
300 mA
4
BG406330
3395
30 mA
2
BG210003
5700
30 mA
4
BG410003
5985
100 mA
2
BG210010
5525
100 mA
4
BG410010
5935
300 mA
2
BG210030
5525
300 mA
4
BG410030
5935
25A
40A
63A
100A
Isolators
Range Highlights
l Conforms to IEC 60947-3
l Utilization category AC22-A
l Available in DP, TP and FP versions in 40A, 63A, 80A & 100A ratings
Current
Rating
(In)
Modules
1 Mod = 17.5 mm
40
2
63
M.R.P.
(`)
Per Unit
M.R.P.
(`)
Per Unit
Modules
1 Mod = 17.5 mm
BF304000
725
4
BF404000
3
BF306300
820
4
BF406300
945
675
3
BF308000
890
4
BF408000
1080
705
3
BF310000
910
4
BF410000
1110
M.R.P.
(`)
Per Unit
Modules
1 Mod = 17.5 mm
BF204000
405
3
2
BF206300
520
80
2
BF208000
100
2
BF210000
Cat. No.
Double Pole (DP)
Cat. No.
Cat. No.
Four Pole (FP)
Three Pole (TP)
920
Note: Standard Pack Quantity for Isolator : DP - 6 Nos., TP - 4 Nos., FP - 3 Nos.
L&T, ESP 01.11.2013
73
Other Protection & Control Devices
Modular Energy Meter
Astronomical Time Switch
New
Cat. No.
M.R.P.
(`)
Per Unit
1-Phase 2-wire 240V, 5-30A
W2DLD050600
2200
3-Phase 4-Wire 240V 10-60A
W4DLD100600
5000
Description
Modular Indicator
Description
Astronomical Time Switch
110-240V 1 C/O - 2 Mod
Surge Protection Device
New
Cat. No.
M.R.P.
(`)
Per Unit
T2DDT7
3150
Cat. No.
M.R.P.
(`)
Per Unit
New
Cat. No.
M.R.P.
(`)
Per Unit
Single Phase Indicator-Red 1 Mod
MM1NDV04
560
Type 2 SPDs - ( 8/20 micro sec)
Single Phase Indicator-Yellow 1 Mod
MM1NDW04
560
40kA, 1P+N, 2 Mod
LPDA2040P2
6125
Single Phase Indicator-Blue 1 Mod
MM1NDX04
560
40kA, 3P+N, 4 Mod
LPDA2040P4
12000
MM3ND04
780
15kA, 1P+N, 2 Mod
LPDA2015P2
5000
15kA, 3P+N, 4 Mod
LPDA2015P4
10005
Cat. No.
M.R.P.
(`)
Per Unit
-
-
Description
Three Phase Indicator-Red, Yellow & Blue 1Mod
Analog Time Switch
Description
New
Description
Type 1 SPDs - (10/350 micro sec)*
* Contact nearest L&T branch office for its availability.
Cat. No.
M.R.P.
(`)
Per Unit
Time Switch - 1 Mod (1 NO)
J6107B204
2450
Time Switch - 3 Mod (1 C/O)
J6118B304
2400
Description
Single Phase ACCL
New
Automatic Source Changeover
With Current Limiter
Digital Time Switch
Cat. No.
M.R.P.
(`)
Per Unit
30A/1.5A (300W)
ACCL113001O
1500
30A/2.5A (500W)
ACCL113002O
1500
30A/3A (600W)
ACCL113003O
1500
30A/4A (800W)
ACCL113004O
1500
30A/5A (1000W)
ACCL113005O
1500
30A/6A (1200W)
ACCL113006O
1500
Description
EB/DG (Load)
Cat. No.
M.R.P.
(`)
Per Unit
Crono Time Switch 110-240V AC 1 C/O- 2 Mod
67DDT0
1875
30A/8A (1600W)
ACCL113008O
1500
Pulse Time Switch, 110-240V AC 1 C/O- 2 Mod
67DDT9
1825
30A/10A (1800W)
ACCL113010O
1500
Description
74
L&T, ESP 01.11.2013
Distribution Boards
Range Highlights
•
•
•
•
As per IS 8623
Aesthetically superior to suit the interiors
Suitable for flush and surface mounting
Ready to use DBs - provided with 100A phase Bus-bar, Neutral
bar, Cement Spill Protector, Earth bar and interconnecting
wires as standard accessories*
SPN Distribution Boards
TPN Distribution Boards
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
6 way
6
LTSC06N
905
8 way
8
LTSC08N
1030
12 way
12
LTSC12N
16 way
16
18 way
18
Description
• Provided with removable top and bottom gland
plates with adequate knockouts for easy wiring
• DBs made up of thick CRCA sheet steel &
powder coated with RAL 9003 shade
• 200A vertical bus-bar with10kA fault withstand
capacity for 1 sec. in VTPN DBs
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
4 way +
4 + 12
LTTC04NE
2140
4 way
8 + 12
LTTC04N
2275
1220
6 way
8 + 18
LTTC06N
2765
LTSC16N
1540
8 way
8 + 24
LTTC08N
3215
LTSC18N
2035
12 way
8 + 36
LTTC12N
4905
IP30 - Single Door
Description
IP30 - Single Door
IP43 - Double Door : Plain
IP43 - Double Door : Plain
4 way
4
LTSD04N
1155
4 way +
4 + 12
LTTD04NE
2855
6 way
6
LTSD06N
1325
4 way
8 + 12
LTTD04N
2895
8 way
8
LTSD08N
1450
6 way
8 + 18
LTTD06N
3555
12 way
12
LTSD12N
1790
8 way
8 + 24
LTTD08N
4275
16 way
16
LTSD16N
2170
12 way
8 + 36
LTTD12N
6410
18 way
18
LTSD18N
2920
16 way
8 + 48
LTTD16N
7845
IP43 - Double Door : Glazed
IP43 - Double Door : Glazed
4 way
4
LTSD04GN
1405
4 way +
4 + 12
LTTD04GNE
3295
6 way
6
LTSD06GN
1545
4 way
8 + 12
LTTD04GN
3470
8 way
8
LTSD08GN
1650
6 way
8 + 18
LTTD06GN
4265
12 way
12
LTSD12GN
2015
8 way
8 + 24
LTTD08GN
5020
16 way
16
LTSD16GN
2470
12 way
8 + 36
LTTD12GN
7660
18 way
18
LTSD18GN
3050
16 way
8 + 48
LTTD16GN
9305
TPN Horizontal PPI Distribution Boards
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
6 + 2 way
8 + 6 + 18
LTTPD06N
6510
8 + 2 way
8 + 6 + 24
LTTPD08N
8170
6490
10 + 2 way
8 + 6 + 30
LTTPD10N
8570
LTHPD10N
7590
12 + 2 way
8 + 6 + 36
LTTPD12N
9320
8 + 6 + 36
LTHPD12N
8565
16 + 2 way
8 + 6 + 48
LTTPD16N
9810
8 + 6 + 42
LTHPD14N
9665
12 + 2 way +
MCCB + 6 + 36
LTTPD12MN
8860
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
4 + 2 way
8 + 6 + 12
LTHPD04N
4650
6 + 2 way
8 + 6 + 18
LTHPD06N
5550
8 + 2 way
8 + 6 + 24
LTHPD08N
10 + 2 way
8 + 6 + 30
12 + 2 way
14 + 2 way
Description
IP43 - Double Door : Plain
6 + 2 way
8 + 2 way
12 + 2 way
8 + 6 + 12
8 + 6 + 18
8 + 6 + 24
8 + 6 + 36
Description
IP43 - Double Door : Plain
IP43 - Double Door : Glazed
4 + 2 way
TPN Tier PPI Distribution Boards
IP43 - Double Door : Glazed
LTHPD04GN
5280
6 + 2 way
8 + 6 + 18
LTTPD06GN
7270
LTHPD06GN
6310
8 + 2 way
8 + 6 + 24
LTTPD08GN
8370
LTHPD08GN
7550
10 + 2 way
8 + 6 + 30
LTTPD10GN
8665
LTHPD12GN
10615
12 + 2 way
8 + 6 + 36
LTTPD12GN
9720
16 + 2 way
8 + 6 + 48
LTTPD16GN
10160
MCCB + 6 + 36
LTTPD12MGN
9500
12 + 2 way +
* For flexi DB, Phase bus-bar & connecting wires are not part of
standard accessories
L&T, ESP 01.11.2013
Note: Provision to mount MCCB type DH 3P up to 200A and
4P up to 160A as incomer.
75
Distribution Boards
TPN Vertical Distribution Boards
(Modular Incomer)
TPN Vertical Distribution Boards
(MCCB Incomer)
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
4 way
8 + 12
LTVC04N
6030
6 way
8 + 18
LTVC06N
7090
8 way
8 + 24
LTVC08N
12 way
8 + 36
LTVC12N
Description
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
4 way
MCCB + 12
LTVD04MN
8065
6 way
MCCB + 18
LTVD06MN
9835
7560
8 way
MCCB + 24
LTVD08MN
10365
10550
12 way
MCCB + 36
LTVD12MN
13585
16 way
MCCB + 48
LTVD16MN
17170
Description
IP43 - Double Door : Plain
IP30 - Single Door
IP43 - Double Door : Plain
4 way
8 + 12
LTVD04N
7115
6 way
8 + 18
LTVD06N
8660
4 way
MCCB + 12
LTVD04MGN
9795
8 way
8 + 24
LTVD08N
9135
6 way
MCCB + 18
LTVD06MGN
11155
12 way
8 + 36
LTVD12N
12095
8 way
MCCB + 24
LTVD08MGN
12345
16 way
8 + 48
LTVD16N
16665
12 way
MCCB + 36
LTVD12MGN
15985
16 way
MCCB + 48
LTVD16MGN
19185
IP43 - Double Door : Glazed
4 way
8 + 12
LTVD04GN
8415
6 way
8 + 18
LTVD06GN
10710
8 way
8 + 24
LTVD08GN
13055
12 way
8 + 36
LTVD12GN
14305
16 way
8 + 48
LTVD16GN
17490
TPN Phase Segregated
Distribution Boards
Description
No. of
Modules
IP43 - Double Door : Glazed
Note: Provision to mount MCCB type DH 3P up to 200A and 4P
up to 160A as incomer.
TPN Phase Selector
Distribution Boards
Cat. Nos.
M.R.P.
(`)
Per Unit
Description
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
9050
IP30 - Single Door
IP30 - Single Door : (Modular incomer)
4 way
8 + 12 + 12
LTPSC04N
6120
4 way
8 + 12
LTPCC04NS
6 way
8 + 12 + 18
LTPSC06N
6525
6 way
8 + 18
LTPCC06NS
9620
8 way
8 + 12 + 24
LTPSC08N
7100
8 way
8 + 24
LTPCC08NS
10600
12 way
8 + 12 + 36
LTPSC12N
8480
12 way
8 + 36
LTPCC12NS
11560
IP43 - Double Door : Plain
IP43 - Double Door : Plain (Modular incomer)
4 way
8 + 12 + 12
LTPSD04N
7115
4 way with single front plate
6 + 12
LTPCD04NES
10120
6 way
8 + 12 + 18
LTPSD06N
8040
4 way
8 + 12
LTPCD04NS
10160
8 way
8 + 12 + 24
LTPSD08N
8800
6 way
8 + 18
LTPCD06NS
10335
12 way
8 + 12 + 36
LTPSD12N
11385
8 way
8 + 24
LTPCD08NS
10845
12 way
8 + 36
LTPCD12NS
12410
IP43 - Double Door : Plain (MCCB incomer)
4 way
MCCB + 12 + 12
LTPSD04MN
6 way
MCCB + 12 + 18
LTPSD06MN
11480
8 way
MCCB + 12 + 24
LTPSD08MN
13150
12 way
MCCB + 12 + 36
LTPSD12MN
14900
10050
Note: Provision to mount MCCB type DH 3P up to 200A and
4P up to 160A as incomer.
76
L&T, ESP 01.11.2013
Distribution Boards
Flexi Distribution Boards
Cable End Boxes
Cat. Nos.
M.R.P.
(`)
Per Unit
CEB for 4 Way SPN DD DB
LTSD04CBN
455
CEB for 6 Way SPN DD DB
LTSD06CBN
510
CEB for 8 Way SPN DD DB
LTSD08CBN
515
CEB for 12 Way SPN DD DB
LTSD12CBN
580
CEB for 16 Way SPN DD DB
LTSD16CBN
800
CEB for 18 Way SPN DD DB
LTSD18CBN
870
Description
CEB for SPN DBs
No. of
Modules
Description
Cat. Nos.
M.R.P.
(`)
Per Unit
IP43 - Double Door : Plain
2 row 28 module
28
LTFD228N
3620
3 row 42 module
42
LTFD342N
4320
4 row 56 module
56
LTFD456N
4740
2 row 28 module
28
LTFD228GN
3690
3 row 42 module
42
LTFD342GN
4560
4 row 56 module
56
LTFD456GN
4830
IP43 - Double Door : Glazed
Enclosures
CEB for TPN DBs
LTTD04CBNE
730
CEB for 4 Way TPN DD DB
LTTD04CBN
840
CEB for 6 Way TPN DD DB
LTTD06CBN
910
CEB for 8 Way TPN DD DB
LTTD08CBN
1360
CEB for 12 Way TPN DD DB
LTTD12CBN
1860
CEB for 16 Way TPN DD DB
LTTD16CBN
2095
CEB for 2 + 4 Way Horizontal PPI DD DB
LTHPD04CBN
940
CEB for 2 + 6 Way Horizontal PPI DD DB
LTHPD06CBN
1465
CEB for 2 + 8 Way Horizontal PPI DD DB
LTHPD08CBN
1675
CEB for 2 + 12 Way Horizontal PPI DD DB
LTHPD12CBN
1980
CEB for 2 + 6 Way Tier PPI DD DB
LTTPD06CBN
880
CEB for 2 + 8 Way Tier PPI DD DB
LTTPD08CBN
920
CEB for 2 + 10 Way Tier PPI DD DB
LTTPD10CBN
1120
CEB for 2 + 12 Way Tier PPI DD DB
LTTPD12CBN
1675
CEB for 4 Way TPN DD ECO DB
CEB for TPN Horizontal PPI Dbs
Description
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
1 way
1
LTMC01NE
410
2 way
2
LTMC02N
435
4 way
4
LTMC04N
445
6 way
6
LTMC06N
685
CEB for TPN Tier PPI Dbs
CEB for 2 + 12 Way Tier PPI DD DB (MCCB) LTTPD12MCBN
LTVDXXCBN
725
LTVDXXMCBN
2270
LTFDxxCBN
725
CEB for 4 Way TPN Modular (I/C) DB
LTPSD04CBN
1385
CEB for 6 Way TPN Modular (I/C) DB
LTPSD06CBN
1655
CEB for 8 Way TPN Modular (I/C) DB
LTPSD08CBN
2200
CEB for 12 Way TPN Modular (I/C) DB
LTPSD12CBN
3290
CEB for 4 Way MCCB (I/C) DB
LTPSD04MCBN
1690
CEB for Vertical DD (Modular I/C)
Metal Plug and Socket DBs
1880
CEB for Vertical TPN DBs
CEB for Vertical DD (MCCB I/C)
CEB for Flexi DBs
CEB for Phase Segregated DB
Description
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
10A 2Pin + SC
1
LTMP110N
1060
CEB for 6 Way MCCB (I/C) DB
LTPSD06MCBN
2025
20A 2Pin + SC
1
LTMP120N
1130
CEB for 8 Way MCCB (I/C) DB
LTPSD08MCBN
2380
20A 2Pin + SC
2
LTMP220N
1165
CEB for 12 Way MCCB (I/C) DB
LTPSD12MCBN
3555
20A 3Pin + SC
3
LTMP320N
2380
32A 3Pin + SC
3
LTMP332N
2790
32A 3Pin + SC
4
LTMP432N
2950
63A 5Pin + SC
4
LTMP463N
10370
SC - Scraping Earth
Plastic Plug and Socket DBs
Customized Distribution Boards
For TV Telephone DBs, pre-wired DBs, 8 Segment DBs and
other customized DBs, please contact nearest L&T office.
Description
No. of
Modules
Cat. Nos.
M.R.P.
(`)
Per Unit
16A 3Pin + SC
4
LTPP316N
1990
32A 3Pin + SC
4
LTPP332N
2700
32A 5Pin + SC
6
LTPP532N
3300
63A 5Pin + SC
8
LTPP563N
9330
SC - Scraping Earth
L&T, ESP 01.11.2013
77
Selection Chart: Fuse Protected Feeders
TYPE '2' Co-ordination, Iq=50 kA at 415V, 3Ø, 50 Hz as per IS/IEC 60947-4-1 standard
l
l
l
l
l
l
l
l
l
The Full Load Current (FLC) indicated for 3-phase motors are of 'squirrel-cage Induction motors' at full load.
Contactors / S-D-Fs indicated are of the minimum ratings. Higher rating of contactors and S-D-Fs can be used.
Selection chart is for standard 3-phase, squirrel cage motor with average power factor and efficiency.
Selection is valid only for complete L&T combinations.
Compliance to Type '2' co-ordination is not assured in case these combinations are changed to accommodate another brand / rating of
products like S-D-F / Fuse etc.
All S-D-F ratings are AC-23A as per IS/IEC 60947-3, IEC 60947-3 & EN 60947-3
Normal motor starting time (<=5 Sec) is assumed. Selection for motors with longer starting times can be made available on request.
These charts remain same for IE1 and IE2 motors
For Type 2 charts for fuseless feeders, kindly contact the nearest branch office.
DOL STARTER FEEDERS
Motor: 3Ø, 415V, 50 Hz
Overload Relay
Nominal Backup fuse
hp
kW
In (A)
Contactor
Type
Type
Range (A)
Type
Rating (A)
0.16
0.12
0.51
MNX 9
MN 2
0.45 - 0.75
HF
2
FN 32 / FNX 32
0.25
0.18
0.6
MNX 9
MN 2
0.45 - 0.75
HF
2
FN 32 / FNX 32
0.33
0.25
0.8
MNX 9
MN 2
0.6 - 1.0
HF
2
FN 32 / FNX 32
0.5
0.37
1.2
MNX 9
MN 2
0.9 - 1.5
HF
4
FN 32 / FNX 32
0.75
0.55
1.5
MNX 9
MN 2
1.4 - 2.3
HF
4
FN 32 / FNX 32
1
0.75
2
MNX 9
MN 2
1.4 - 2.3
HF
6
FN 32 / FNX 32
1.5
1.1
2.7
MNX 9
MN 2
2.0 - 3.3
HF
8
FN 32 / FNX 32
1.75
1.3
3
MNX 9
MN 2
2.0 - 3.3
HF
8
FN 32 / FNX 32
2
1.5
3.5
MNX 9
MN 2
3-5
HF
10
FN 32 / FNX 32
3
2.2
4.92
MNX 9
MN 2
4.5 - 7.5
HF
16
FN 32 / FNX 32
4
3
6
MNX 9
MN 2
4.5 - 7.5
HF
16
FN 32 / FNX 32
5
3.7
7.5
MNX 9
MN 2
4.5 - 7.5
HF
20
FN 32 / FNX 32
5.5
4
8.5
MNX 9
MN 2
6 - 10
HF
20
FN 32 / FNX 32
7.5
5.5
11
MNX 12
MN 2
9 - 15
HF
32
FN 32 / FNX 32
10
7.5
14.5
MNX 22
MN 2
9 - 15
HF
40
FN 63 / FNX 63
12.5
9.3
17.3
MNX 25
MN 2
14 - 23
HF
50
FN 63 / FNX 63
15
11
21
MNX 25
MN 2
14 - 23
HF
63
FN 63 / FNX 63
17.5
13
24
MNX 25
MN 2
20 - 33
HF
63
FN 63 / FNX 63
20
15
29
MNX 40
MN 2
20 - 33
HN, 000*
63
FN 100 / FNX 100*
25
18.5
35
MNX 40
MN 2
24 - 40
HN, 000*
80
FN 100 / FNX 100*
30
22
40
MNX 45
MN 5
30 - 50
HN, 000*
80
FN 100 / FNX 100*
40
30
54
MNX 70
MN 5
45 - 75
HN, 000*
100
FN 100 / FNX 100*
50
37
68
MNX 80
MN 5
45 - 75
HN, 000
125
FN 125 / FNX 125
60
45
81
MNX 95
MN 5
66 - 110
HN, 000
125
FN 125 / FNX 125
75
55
94
MNX 95
MN 5
66 - 110
HN, 00#
160
FN 160 / FNX 160#
100
75
130
MNX 140
MN 12
90 - 150
HN, 0
200
FN 200 / FNX 200
110
80
139
MNX 140
MN 12
90 - 150
HN, 0
200
FN 200 / FNX 200
120
90
157
MNX 185
MN 12
135 - 225
HN, 1
250
FN 250 / FNX 250
150
110
189
MNX 225
MN 12
135 - 225
HN, 1
250
FN 250 / FNX 250
170
125
207
MNX 265
MN 12
135 - 225
HN, 1
315
FN 315 / FNX 315
180
132
226
MNX 265
MN 12
180 - 300
HN, 1
315
FN 315 / FNX 315
200
150
248
MNX 265
MN 12
180 - 300
HN, 2
400
FN 400 / FNX 400
215
160
270
MNX 325
MN 12
180 - 300
HN, 2
400
FN 400 / FNX 400
240
180
298
MNX 325
MN 12
180 - 300
HN, 2
400
FN 400 / FNX 400
270
200
336
MNX 400
MN 12
270 - 450
HN, 3
500
FN 630 / FNX 630
300
225
360
MNX 400
MN 12
270 - 450
HN, 3
500
FN 630 / FNX 630
335
250
420
MNX 550
MN 12
270 - 450
HN, 3
500
FN 630 / FNX 630
370
275
440
MNX 550
MN 12
270 - 450
HN, 3
630
FN 630 / FNX 630
425
315
529
MNX 550
MN 12L
340 - 570
HN, 3
630
FN 630 / FNX 630
452
335
550
MNX 650
MN 12L
340 - 570
HN, 3
800
FN 800 / FNX 800
S-D-F
* : Only size '000' fuses to be used with FNX 100 S-D-F.
# : Only size '00' fuses to be used with FNX 160 S-D-F.
78
L&T, ESP 01.11.2013
Selection Chart: Fuse Protected Feeders
STAR DELTA STARTER FEEDERS
R
Y
B
N
Fuse
Note : It is recommended that Star Delta configuration is used
along with Star-Delta Timer with Pause Time and not On-Delay
Timer. Recommended timer Cat No is 12SDT0.
Line
Contactor
Delta
Contactor
Star
Contactor
Relay
V1
U1
W1
3Ø Motor
V2
W2
U2
Ratings at 3Ø, 415V, 50 Hz
hp
kW
Contactor
Current, In (A)
Overload Relay
Nominal Back up fuse
Line
Phase
Star
Line
Delta
Type
Range (A)
Type
Rating (A)
S-D-F
1
0.75
2
1.2
MNX 9
MNX 9
MNX 9
MN 2
0.9 - 1.5
HF
4
FN 32 / FNX 32
1.5
1.1
2.7
1.6
MNX 9
MNX 9
MNX 9
MN 2
1.4 - 2.3
HF
4
FN 32 / FNX 32
1.75
1.3
3
1.7
MNX 9
MNX 9
MNX 9
MN 2
1.4 - 2.3
HF
4
FN 32 / FNX 32
2
1.5
3.5
2.0
MNX 9
MNX 9
MNX 9
MN 2
1.4 - 2.3
HF
6
FN 32 / FNX 32
3
2.2
4.92
2.8
MNX 9
MNX 9
MNX 9
MN 2
2 - 3.3
HF
8
FN 32 / FNX 32
4
3
6
3.5
MNX 9
MNX 9
MNX 9
MN 2
3-5
HF
8
FN 32 / FNX 32
5
3.7
7.5
4.3
MNX 9
MNX 9
MNX 9
MN 2
3-5
HF
10
FN 32 / FNX 32
5.5
4
8.5
4.9
MNX 9
MNX 9
MNX 9
MN 2
3-5
HF
16
FN 32 / FNX 32
7.5
5.5
11
6.4
MNX 9
MNX 9
MNX 9
MN 2
4.5 - 7.5
HF
16
FN 32 / FNX 32
10
7.5
14.5
8.4
MNX 9
MNX 9
MNX 9
MN 2
6 - 10
HF
20
FN 32 / FNX 32
12.5
9.3
17.3
10.0
MNX 9
MNX 12
MNX 12
MN 2
9 - 15
HF
32
FN 32 / FNX 32
15
11
21
12.0
MNX 9
MNX 12
MNX 12
MN 2
9 - 15
HF
32
FN 32 / FNX 32
17.5
13
24
13.9
MNX 12
MNX 18
MNX 18
MN 2
9 - 15
HF
32
FN 32 / FNX 32
20
15
29
16.7
MNX 12
MNX 22
MNX 22
MN 2
14 - 23
HF
40
FN 63 / FNX 63
25
18.5
35
20.2
MNX 18
MNX 25
MNX 25
MN 2
14 - 23
HF
50
FN 63 / FNX 63
30
22
40
23.1
MNX 18
MNX 25
MNX 25
MN 2
20 - 33
HF
63
FN 63 / FNX 63
40
30
54
31.2
MNX 32
MNX 32
MNX 32
MN 2
20 - 33
HN, 000*
63
FN 100 / FNX 100*
50
37
68
39.3
MNX 32
MNX 45
MNX 45
MN 5
30 - 50
HN, 000*
80
FN 100 / FNX 100*
60
45
81
46.8
MNX 45
MNX 70
MNX 70
MN 5
30 - 50
HN, 000*
100
FN 100 / FNX 100*
75
55
94
54.3
MNX 45
MNX 70
MNX 70
MN 5
45 - 75
HN, 000*
100
FN 100 / FNX 100*
100
75
130
75.1
MNX 80
MNX 95
MNX 95
MN 5
66 - 110
HN, 00#
160
FN 160 / FNX 160#
110
80
139
80.3
MNX 80
MNX 95
MNX 95
MN 5
66 - 110
HN, 00#
160
FN 160 / FNX 160#
120
90
157
90.6
MNX 80
MNX 95
MNX 95
MN 5
66 - 110
HN, 00#
160
FN 160 / FNX 160#
150
110
189
109
MNX 95
MNX 110
MNX 110
MN 5
66 - 110
HN, 0
200
FN 200 / FNX 200
170
125
207
120
MNX 95
MNX 140
MNX 140
MN 12
90 - 150
HN, 1
250
FN 250 / FNX 250
180
132
226
130
MNX 110
MNX 140
MNX 140
MN 12
90 - 150
HN, 1
250
FN 250 / FNX 250
200
150
248
143
MNX 110
MNX 185
MNX 185
MN 12
135 - 225
HN, 1
250
FN 250 / FNX 250
215
160
270
156
MNX 140
MNX 225
MNX 225
MN 12
135 - 225
HN, 1
315
FN 315 / FNX 315
240
180
298
172
MNX 140
MNX 225
MNX 225
MN 12
135 - 225
HN, 1
315
FN 315 / FNX 315
270
200
336
194
MNX 265
MNX 265
MNX 265
MN 12
135 - 225
HN, 2
400
FN 400 / FNX 400
300
225
360
208
MNX 265
MNX 265
MNX 265
MN 12
135 - 225
HN, 2
400
FN 400 / FNX 400
335
250
420
242
MNX 265
MNX 325
MNX 325
MN 12
180 - 300
HN, 3
500
FN 630 / FNX 630
370
275
440
254
MNX 265
MNX 325
MNX 325
MN 12
180 - 300
HN, 3
500
FN 630 / FNX 630
425
315
529
305
MNX 325
MNX 550
MNX 550
MN 12
270 - 450
HN, 3
630
FN 630 / FNX 630
452
335
550
318
MNX 400
MNX 550
MNX 550
MN 12
270 - 450
HN, 3
630
FN 630 / FNX 630
475
355
589
340
MNX 400
MNX 550
MNX 550
MN 12
270 - 450
HN, 3
630
FN 630 / FNX 630
502
375
615
355
MNX 400
MNX 550
MNX 550
MN 12
270 - 450
HN, 3
630
FN 630 / FNX 630
* : Only size '000' fuses to be used with FNX 100 S-D-F.
# : Only size '00' fuses to be used with FNX 160 S-D-F.
L&T, ESP 01.11.2013
79
Air Insulated MV Switchgear
Type tested indoor MV Panel upto 36 kV system voltage
Complete range from 630A to 4000A
Short time rating upto 40 kA for 3sec
Metal clad, fully compartmentalised panel
Floor mounted VCB
Internal Arc compliant as per IEC 62271-200
In-built comprehensive safety interlocks
Discontinued Products
The following products have been discontinued :
Product Group
Range
Controlgear
MPX Capacitor Duty Contactors
S-D-F
MIL Kit of FN/FNX Switch
MCCB
DU125, 3P & 4P (32A to 100A)
Capacitors
LTCCS Standard Duty Capacitors
L&T, ESP 01.11.2013
81
All prices are on maximum retail price basis inclusive of
Excise Duty and VAT / Sales Tax as applicable.
General
Terms
Warranty
Policy
Prices are subject to revision without notice.
All the products listed in the price list carry a warranty,
against manufacturing defects for a period of 18* months
from the date of purchase.
Should the product prove to be defective due to faulty
workmanship or otherwise, we will remedy the defect or
replace the faulty parts or the whole product at our
discretion, as soon as possible, free of cost.
The warranty is however subject to the provision of proper
usage, efficient maintenance and does not cover defects
arising out of fire, accident, inefficient maintenance, faulty
operation and willful or accidental damage. It also does not
cover damage to power electronic components like
thyristors & IGBTs, which fail predominantly due to overtemperature & over-voltage. The user needs to take
adequate precautions to eliminate these conditions. The
manufacturer shall not be liable for any consequential loss,
injury or damages attributable to defect or failure of
its products.
Comprehensive
Service Support
82
L&T has over four decades of experience in providing
after sales service for low voltage distribution systems in
every type of industry & commercial complex in India.
L&T offers the following services, partnering you
in your maintenance of low voltage distribution products :
• Regular Maintenance
• Preventive Maintenance Programme
• On Call
• Annual Maintenance Contract
• Product Support for Managing Obsolescence Retrofitting & Upgradation of your switchgear products.
L&T, ESP 01.11.2013
Electrical Standard Products (ESP) Branch Offices:
REGISTERED OFFICE AND
HEAD OFFICE
L&T House, Ballard Estate
P. O. Box 278
Mumbai 400 001
Tel: 022-67525656
Fax: 022-67525858
Website: www.Larsentoubro.com
ELECTRICAL STANDARD PRODUCTS (ESP)
501, Sakar Complex I
Opp. Gandhigram Rly. Station
Ashram Road
Ahmedabad 380 009
Tel: 079-66304006-11
Fax: 079-66304025
e-mail: esp-ahm@LNTEBG.com
38, Cubbon Road, P. O. Box 5098
Bangalore 560 001
Tel: 080-25020100 / 25020324
Fax: 080-25580525
e-mail: esp-blr@LNTEBG.com
131/1, Zone II
Maharana Pratap Nagar
Bhopal 462 011
Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19
Fax: 0755-3080502
e-mail: esp-bho@LNTEBG.com
Plot No. 559, Annapurna Complex
Lewis Road
Bhubaneswar 751 014
Tel: 0674-6451342, 2436690, 2436696
Fax: 0674-2537309
e-mail: nayakd@LNTEBG.com
SCO 32, Sector 26-D
Madhya Marg, P. O. Box 14
Chandigarh 160 019
Tel: 0172-4646840, 4646853
Fax: 0172-4646802
e-mail: esp-chd@LNTEBG.com
L&T Construction Campus
TC-1 Building, II Floor
Mount-Poonamallee Road
Manapakkam
Chennai 600 089
Tel: 044-2270 6800
Fax: 044-22706940
e-mail: esp-maa1@LNTEBG.com
67, Appuswamy Road
Post Bag 7156
Opp. Nirmala College
Coimbatore 641 045
Tel: 0422-2588120 / 1 / 5
Fax: 0422-2588148
e-mail: esp-cbe@LNTEBG.com
Khairasol, Degaul Avenue
Durgapur 713 212
Tel: 2559848, 2559849, 2559844
Fax: 0343-2553614
e-mail: esp-dgp@LNTEBG.com
5, Milanpur Road, Bamuni Maidan
Guwahati 781 021
Tel: +91 8876554410 / 8876554417
Fax: 361-2551308
e-mail: hazrasudipto@LNTEBG.com
II Floor, Vasantha Chambers
5-10-173, Fateh Maidan Road
Hyderabad 500 004
Tel: 040-67015052
Fax: 040-23296468
e-mail: esp-hyd@LNTEBG.com
Monarch Building, 1st Floor
D-236 & 237, Amrapali Marg
Vaishali Nagar
Jaipur 302 021
Tel: 0141-4385914 to 18
Fax: 0141-4385925
e-mail: esp-jai@LNTEBG.com
Akashdeep Plaza, 2nd Floor
P. O. Golmuri
Jamshedpur 831 003
Jharkhand
Tel: 0657-2312205 / 38
Fax: 0657-2341250
e-mail: esp-jam@LNTEBG.com
Skybright Bldg; M. G. Road
Ravipuram Junction, Ernakulam
Kochi 682 016
Tel: 0484-4409420 / 4 / 5 / 7
Fax: 0484-4409426
e-mail: esp-cok@LNTEBG.com
3-B, Shakespeare Sarani
Kolkata 700 071
Tel: 033-44002572 / 3 / 4
Fax: 033-22821025 / 7587
e-mail: esp-ccu@LNTEBG.com
A28, Indira Nagar, Faizabad Road
Lucknow 226 016
Tel: 0522-4929905/04
Fax: 0522-2311671
e-mail: esp-Lko@LNTEBG.com
No: 73, Karpaga Nagar, 8th Street
K. Pudur
Madurai 625 007
Tel: 0452-2537404, 2521068
Fax: 0452-2537552
e-mail: esp-mdu@LNTEBG.com
EBG North Wing Office-Level 2
Gate 7, Powai Campus
Mumbai 400 072
Tel: 022-67052874 / 2737 / 1156
Fax: 022-67051112
e-mail: esp-bom@LNTEBG.com
12, Shivaji Nagar
North Ambajhari Road
Nagpur 440 010
Tel: 0712-2260012/6606421
Fax: 2260030/6606434
e-mail: esp-nag@LNTEBG.com
32, Shivaji Marg
P. O. Box 6223
New Delhi 110 015
Tel: 011-41419514 / 5 / 6
Fax: 011-41419600
e-mail: esp-del@LNTEBG.com
L&T House
P. O. Box 119
191/1, Dhole Patil Road
Pune 411 001
Tel: 020-66033395/66033279
Fax: 020-26164048/26164910
e-mail: esp-pnq@LNTEBG.com
Crystal Tower,
4th Floor, G. E. Road
Telibandha
Raipur - 492 006
Tel: 0771-4283214
e-mail: esp-raipur@LNTEBG.com
3rd Floor
Vishwakarma Chambers
Majura Gate, Ring Road
Surat 395 002
Tel: 0261-2473726
Fax: 0261-2477078
e-mail: esp-sur@LNTEBG.com
Radhadaya Complex
Old Padra Road
Near Charotar Society
Vadodara 390 007
Tel: 0265-6613610 / 1 / 2
Fax: 0265-2336184
e-mail: esp-bar@LNTEBG.com
48-8-16, Dwarakanagar
Visakhapatnam 530 016
Tel: 0891 670 1125 to 30
Fax: 0891 670 1139
e-mail: esp-viz@LNTEBG.com
Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.
Product photographs shown, are for representative purposes only.
Larsen & Toubro Limited Electrical Standard Products
Powai Campus, Mumbai 400 072
Customer Interaction Center (CIC)
BSNL / MTNL (toll free) : 1800 233 5858
Reliance (toll free)
: 1800 200 5858
Tel : 022 6774 5858, Fax : 022 6774 5859
E-mail : cic@LNTEBG.com Website : www.LNTEBG.com
SP 50494 K