Dewetron DEWE-201 is a rugged, small-size standalone instrument with 16 MDAQ input channels for voltage, ICP®, bridge or strain measurements. It also features 2 counter inputs (encoder) and optional CAN-bus interface. The DEWE-201 offers local data storage or online data transfer via Ethernet. Its specifications include operating temperatures from 0 °C to +50 °C, storage temperatures from -20 °C to +70 °C, and a humidity range of 10% to 80%.
PDF
Document
Advertisement
Advertisement
Automotive Energy & Power Analysis Field Service Environmental Research & Development DEWE-201 Technical reference manual ISO9001 ... the precision signal conditioning company www.dewetr o n .c om Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H. This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners. Table of content Content General Information, Safety Instructions 5 Warranty Information… ……………………………………………………………………… 5 Support………………………………………………………………………………………… 5 Printing History………………………………………………………………………………… 5 Safety symbols in the manual… …………………………………………………………… 6 Safety instructions for all DEWETRON systems… ……………………………………… 7 Environmental Considerations… …………………………………………………………… 8 Main System 9 DEWE-201 Data Acquisition System… …………………………………………………… 9 System specifications………………………………………………………………………… 9 Connectors… ………………………………………………………………………………… 10 A/D & D/A Conversion A1 Internal Wiring B1 CE-Certificate of conformity C1 DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 3 Table of content 4 General Information, Safety Instructions Notice The information contained in this document is subject to change without notice. DEWETRON elektronische Messgeraete Ges.m.b.H. (DEWETRON) shall not be liable for any errors contained in this document. DEWETRON MAKES NO WARRANTIES OF ANY KIND WITH REGARD TO THIS DOCUMENT, WHETHER EXPRESS OR IMPLIED. DEWETRON SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DEWETRON shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document or the use of the information in this document. Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and service office. Support For any support please contact your local distributor first or DEWETRON directly. For Asia and Europe, please contact: For the Americas, please contact: DEWETRON Ges.m.b.H. Parkring 4 A-8074 Graz-Grambach AUSTRIA Tel.: +43 316 3070 Fax: +43 316 307090 Email: [email protected] Web: http://www.dewetron.com DEWETRON, Inc. 10 High Street, Suite K Wakefield, RI 02879 U.S.A. Tel.: +1 401 284 3750 Toll-free: +1 877 431 5166 Fax: +1 401 284 3755 Email: [email protected] Web: http://www.dewamerica.com The telephone hotline is available Monday to Friday between 08:00 and 17:00 CET (GMT +1:00) The telephone hotline is available Monday to Friday between 08:00 and 17:00 GST (GMT -5:00) Restricted Rights Legend Use austrian law for duplication or disclosure. DEWETRON GesmbH Parkring 4 A-8074 Graz-Grambach / Austria Printing History Please refer to the page bottom for printing version. Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H. This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners. DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 5 Safety instructions Safety symbols in the manual Indicates hazardous voltages. WARNING Calls attention to a procedure, practice, or condition that could cause bodily injury or death. CAUTION Calls attention to a procedure, practice, or condition that could possibly cause damage to equipment or permanent loss of data. WARNINGS The following general safety precautions must be observed during all phases of operation, service, and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customer’s failure to comply with these requirements. All accessories shown in this document are available as option and will not be shipped as standard parts. 6 For safety reasons max. 50 V may be applied to the BNC input-connectors! Refer to the regulation of maximum allowable touch potential. Safety instructions Safety instructions for all DEWETRON systems The DEWETRON data acquisition systems may only be installed by experts. Read your manual before operating the system. Observe local laws when using the instrument. Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth terminal), a non interruptible safety earth ground must be provided from the mains power source to the product input wiring terminals or supplied power cable. DO NOT operate the product in an explosive atmosphere or in the presence of flammable gases or fumes and do not bring the system in contact with water. DO NOT operate damaged equipment: Whenever it is possible that the safety protection features built into this product have been impaired, either through physical damage, excessive moisture, or any other reason, REMOVE POWER and do not use the product until safe operation can be verified by service-trained personnel. If necessary, return the product to a DEWETRON sales and service office for service and repair to ensure that safety features are maintained. Keep away from live circuits: Operating personnel must not remove equipment covers or shields. Procedures involving the removal of covers or shields are for use by service-trained personnel only. Under certain conditions, dangerous voltages may exist even with the equipment switched off. To avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal unless you are qualified to do so. No modifications are allowed at the instrument. The fuse in the power module has to be replaced by the same type. For continued protection against fire, replace the line fuse(s) only with fuse(s) of the same voltage and current rating and type. DO NOT use repaired fuses or short-circuited fuse holder labels and print on the power module may not be removed. DO NOT service or adjust alone. Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present. DO NOT substitute parts or modify equipment: Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the product. Return the product to a DEWETRON sales and service office for service and repair to ensure that safety features are maintained. Before opening the instrument (experts only) or exchanging the fuse in the power module disconnect power! Don’t touch internal wiring! Don’t use higher supply voltage than specified and take care of the correct polarity, otherwise the system will be damaged! Use only original plugs and cables for harnessing. Install filler-panels in unused slots. The power-cable and -connector serve as Power-Breaker. The cable must not exceed 10 feet, disconnect function must be possible without tools. Keep the ventilation slots free and check them frequently to avoid an overheating of the system. The cleaning interval of the filter pads depends on the environmental conditions. Safety of the operator and the unit depend on following these rules. DEWETRON is not responsible for any damage or injury that could result from improper connection or misuse! DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 7 General Information CAUTION The system BIOS is protected by password. Any change in the BIOS may cause a system crash. When the system is booting, do not press ESC-button on keyboard. This may clear the BIOS settings and cause system faults. Any change in the file structure as deleting or adding files or directories might cause a system crash. Before installing software updates contact DEWETRON or your local distributor. Use only software packages which are released by DEWETRON. Further informations are also available in the internet (http://www.dewetron.com). After power off the system wait at least 10 seconds before switching the system on again. Otherwise the system may not boot correct. This prolongs also the life of all system components. Environmental Considerations Information about the environmental impact of the product. Product End-of-Life Handling Observe the following guidelines when recycling a DEWETRON system: System and Components Recycling Production of these components required the extraction and use of natural resources. The substances contained in the system could be harmful to your health and to the environment if the system is improperly handled at it's end of life! Please recycle this product in an appropriate way to avoid an unnecessary pollution of the environment and to keep natural resources. This symbol indicates that this system complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). Please find further informations about recycling on the DEWETRON web site www.dewetron.com Restriction of Hazardous Substances This product has been classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. This product is known to contain lead. 8 Main System Main System DEWE-201 Data Acquisition System Rugged small-size standalone instrument 16 MDAQ input channels (voltage, ICP®, bridge or strain) 2 counter input (encoder), CAN-bus option RS-485, prepared for EPAD expansion Local data storage or online data transfer via Ethernet A/D converter specs see appendix A System specifications Power supply: Operating temperature: Storage temperature: Humidity (operating): Vibration test: EN 60068-2-6 Vibration test: EN 60721-3-2 Class 2M2 Shocktests: EN 60068-2-27 Dimensions (W x H x D): Weight: MDAQ-AAF4-5-BU MDAQ-FILT-10-S1 MDAQ-FILT-10 MDAQ-FILT-5-BU-S1 MDAQ-FILT-5-BE MDAQ-FILT-5-BU MDAQ-BASE-10 MDAQ-BASE-5 MDAQ-SUB-STG MDAQ-SUB-BRIDGE MDAQ-SUB-ACC-A-x MDAQ-SUB-ACC-x MDAQ-SUB-V-200 MDAQ-V-100 MDAQ-V-10 Channel 0 to 7 Channel 8 to 15 MDAQ-DIRECT DEWE-201 8 to 24 VDC (startup voltage 9 V, lab-mode)* 8 to 24 VDC (startup voltage 12 V, in-vehicle mode)* 8 to 30 VDC (startup voltage 12 V, in-vehicle mode)* 0 °C to +50 °C -20 °C to +70 °C 10 % to 80 %, non condensing 5 % to 95 % rel. humidity Shape Sine Frequency range 10 - 150 Hz Acceleration 2g Sweep rate 1 oct./min. Duration 20 Cycles Test in 3 directions Shape Random Frequency range 10 - 200 Hz Power spectral density 1 m/s² / Hz from 10 – 200 Hz Duration 30 Minutes per axis Shape Half-sine Acceleration amplitude 15 g Duration 11 ms Test in 3 axis, 3 shocks in each axis and direction approx. 285 x 230 x 88 mm (11.2 x 3.5 x 0.9 in.) typ. 4 kg (8.8 lbs), depending on configuration *) for further information please refere to chapter: Smart power supply. DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 9 Main System Connectors Connector overview: 1 2 3 4 5 6 7 8 9 Power supply for accessories (12 VDC ) Lemo FGG.1B.302 10 Power supply input (EGJ.2B.303.CLA) 11 Audio inputs 12 PS/2 connector 13 Ethernet LAN connector 14 DVI connector Power-on button Ground connector Counter inputs CAN interface Digital I/O connector EPAD interface USB interface connectors WLAN antenna 8 910 6 7 5 4 3 2 7 1 14 11 13 12 Typical DEWE-201 front view Note: The location of the connectors might vary from system to system and depends on system configuration Dimensions* 105 238 288 60 15,3 40 88,1 6,3 7,5 * Dimensions in mm (1 inch = 25.4 mm) 10 15,5 3,3 178 215,5 265,5 305 Main System Internal 160 W DC power supply 160 W DC power supply Input: Input range: 8 to 24 VDC (startup voltage min. 9 VDC, lab-mode)* 8 to 24 VDC (startup voltage min. 12 VDC, in-vehicle mode)* DC 15 A Input frequency: Max. input current: *) For further information please refere to chapter: Smart power supply. Internal 140 W DC power supply 140 W DC power supply Input: Input range: 8 to 30 VDC (startup voltage min. 12 VDC)* Input frequency: DC Output: Output power: Output voltages: 140 W +3.3 V (max. 10 A) +5 V (max. 10 A) +5 Vsb (max. 1.5 A) +12 V (max. 4 A) -12 V (max. 0.15 A) *) Only available in ‚in-vehicle mode‘. Power supply pin assignment: 1 2 3 1 2 3 V+ GND Ignition Lemo EGJ.2B.303.CLA SMART Power supply This device is equipped with a smart power supply. It can be configured for two different modes 1.) Lab mode The device is powered through AC mains via an external AC/DC converter. Please set the jumpers as follows: A B C D In this mode the DEWE-201 acts like a standard ATX compatible computer. Note: like all such ATX compatible PC systems, the DEWE-201 will draw a little current also in power-off mode Note: In the lab mode the system won’t boot up below 8V supply voltage. DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 11 Main System 2.) In-vehicle mode The device is powered out of the vehicle. Please set the jumpers as follows: A B C D In this mode, the DEWE-201 senses the IGN pin for automatic power on / shut down. It is recommended to connect the IGN of the vehicle to the IGN pin. Without high level on this Pin, the system won’t start. • • Connect to the vehicles power supply Switch on the ignition. After about 5 seconds the system will start to boot up. (I it supposed that in these 5 seconds the engine has been started) The device now can be shut down using the front button, as usual The device now can be shut down using the windows function, as usual If you switch off the ignition, after about 5 seconds the system will shut down automatically. After about 45 seconds, the device will shut off hard, even if Windows hangs. • • • Note: In the in-vehicle mode, the DEWE-201 will shut off completely after 45 seconds. So it can remain on the power supply also for long term without discharging the battery. Attention: In the in-vehicle mode the system won’t boot up below 11,5V supply voltage. PS/2 mouse / keyboard connector The mouse / keyboard connector could be used to connect a keyboard or an external PS/2 mouse. The connector meets standard PS/2 pin assignment. USB interface connectors (Universal Serial Bus) The USB interface connectors meets standard USB pin assignment. VGA connector The VGA connector offers the possibility to connect a CRT or other standard VGA displays to the system. 5 4 3 2 1 10 9 8 7 6 15-pin mini-SUB-D connector (male) 12 15 14 13 12 11 Schematic Pin assignment 1: Red video 2: Green video / Sync on green 3: Blue video 4: 5: 6: Red video ground 7: Green video ground 8: Blue video ground 9: 10: Ground 11: Ground 12: Data line 13: H-Sync / HV-Sync 14: V-Sync 15: Clock line Main System Some systems have a DVI connector instead or additionally to the VGA. 15-pin mini-SUB-D connector (male) Schematic Pin assignment 1: 2: 3: 4: 5: 6: 7: 8: TDMS-data 2TDMS-data 2+ Shield TDMS-data 2,4 TDMS-data 4TDMS-data 4+ DDC clock DDC data Analog: V-Sync 9: TDMS-data 110: TDMS-data 1+ 11: Shield TDMS-Daten 1,3 12: TDMS-data 313: TDMS-data 3+ 14: +5 volt 15: Ground for +5 volt 16: Hotplug-Detect 17: TDMS-data 018: TDMS-data 0+ 19: Shield TDMS-data 0,5 20: TDMS-data 521: TDMS-data 5+ 22: Shield TDMS-Takt 23: TDMS-clock+ 24: TDMS-clock - C1: Analog: red C2: Analog: green C3: Analog: blue C4: Analog: H-Sync C5: Analog: ground Note: After the start up of the system there are only analog signals available and do not operate with a DVI-DVI cable. The monitor has to be connected to the standard VGA connector with the provided DVI adapter or an DVI-VGA cable (not included). Ethernet connector The DEWE-201 system supports 10/100/1000 BaseT Ethernet with standard RJ45 connector. Power-on button When the power-on button is pressed while the DEWE-201 is already at Windows, the DEWE-201 will shut down. Press the power-on button for more than 3 seconds while the DEWE-201 is starting into Windows or when the DEWE-201 doesn’t shut down at the normal way. Digital I/O connector This connector supports digital input and output lines of the built-in A/D board. If this board does not support digital I/O’s, the connector is not available. The pin assignment is depending on the used A/D board - details are available in appendix B. Ground connector For some kind of measurements, it’s necessary to give the system an additional ground connection. Power supply for accessories To supply your accessories with 12 VDC. Plug in your accessories before starting the DEWE-201, otherwise it could happen that the DEWE-201 will reboot. Lemo FGG.1B.302 DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 13 Main System EPAD connector To connect DEWETRON EPAD modules to the system. 2 3 1 4 4-pin. LEMO connector (female) Pin assginment 1: RS-485 A 2: RS-485 B 3: +12 V 4: GND Shield is connected on housing Counter connector (optional) This connector supports the counter signals of the built-in A/D board. If this board does not support counter signals, the connector is not available. 7 6 5 4 1 2 3 7-pin LEMO connector (female) Pin assginment 1: Source (n) 2: Up_Down (n) 3: Gate (n) 4: GND 5: +5V (max. 1.8 A) 6: +12 V (max. 1.8 A) 7: CNT_GND (n) 14 For safety reasons max. 50 V may be applied to the BNC input-connectors! Refer to the regulation of maximum allowable touch potential. A/D & D/A Conversion A/D & D/A Conversion A/D Conversion Detailed information about the A/D card are not included in this manual. For detailed information see the manufacturer’s A/D card manual. D/A Conversion Detailed information about the D/A card are not included in this manual. For detailed information see the manufacturer’s D/A card manual. DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 A1 A/D & D/A Conversion Notes A2 Internal Wiring Internal Wiring Please find information about the MDAQ amplifiers in the attached DEWE-MDAQ series modules manual. The latest version of the manual can be downloaded from: http://www.dewetron.com/download/index.php?search=MDAQ&catkey=manuals-amplifiers DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 B1 Internal Wiring Notes B2 CE-Certificate of conformity Manufacturer: DEWETRON Elektronische Messgeraete Ges.m.b.H. Address: Parkring 4 A-8074 Graz-Grambach Austria Tel.: +43 316 3070 0 Fax: +43 316 3070 90 e-mail: [email protected] http://www.dewetron.com Name of product: DEWE-201 Kind of product: Dynamic data logger The product meets the regulations of the following EC-directives: 73/23/EEC "Directive on the approximation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits amended by the directive 93/68/EEC" 89/336/EEC "Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility amended by the directives 91/263/EEC, 92/31/ EEC, 93/68/EEC and 93/97/EEC The accordance is proved by the observance of the following standards: L V E M C Safety IEC/EN 61010-1:1992/93 IEC/EN 61010-2-031 IEC 61010-1:1992/300 V CATIII Pol. D. 2 IEC 1010-2-031 Emissions EN 61000-6-4 EN 55011 Class B Immunity EN 61000-6-2 Group standard Graz, October 14, 2008 Place / Date of the CE-marking Dipl.-Ing. Roland Jeutter / Managing director DE-M070305E • DEWE-201 • Technical Reference Manual • Printing version 1.0.5 • March 23, 2009 C1 Notes C2 ">
/

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- 16 MDAQ channels
- 2 counter inputs
- CAN-bus option
- Ethernet interface
- Local storage
- Rugged design
- Small size
- Standalone operation
Frequently asked questions
The DEWE-201 operates on a power supply range of 8 to 24 VDC in lab mode and 8 to 30 VDC in in-vehicle mode. It requires a startup voltage of at least 9 VDC in lab mode and 12 VDC in in-vehicle mode.
The DEWE-201 has approximate dimensions of 285 x 230 x 88 mm.