DEWETRON DEWE-2010 Technical Reference Manual
Dewetron DEWE-2010 is a portable data acquisition system designed for measuring different physical and/or electrical sizes. It supports up to 16 channels with isolation and up to 256 channels with external expansion racks. The DEWE-2010 is a versatile system suitable for a wide range of applications, including automotive, energy & power analysis, aerospace & defense, transportation and general test & measurement.
PDF
Download
Document
Advertisement
Advertisement
Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement DEWE-2010 Technical reference manual ISO9001 www.dewetr o n .c om Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H. This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners. Preface Thank you! Thank you very much for your investment in DEWETRON's unique data acquisition systems. These are top-quality instruments which are designed to provide you years of reliable service. This guide has been prepared to help you get the most from your investment, starting from the day you take it out of the box, and extending for years into the future. This guide includes important startup notes, as well as safety notes and information about keeping your DEWETRON system in good working condition over time. We strongly suggest that you read this entire manual, especially the safety and care sections, as well as to avoid damaging your DEWETRON system. What is the DEWE-2010? This product is used for measuring of different physical and/or electrical sizes (depending on model or configuration). The connection is depending on model or configuration and takes place via safety banana plugs, BNC connectors (± 50V max.), D-SUB connectors (± 50V max.), thermocouple connectors (± 50V max.), BINDER® connectors (± 50V max.) or LEMO® connectors. DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 3 Preface Notes 4 Table of content Content General Information, Safety Instructions 7 Training………………………………………………………………………………………… 7 Calibration……………………………………………………………………………………… 7 Support………………………………………………………………………………………… 7 Service/repairs………………………………………………………………………………… 7 Warranty Information… ……………………………………………………………………… 8 Printing History………………………………………………………………………………… 8 Safety symbols in the manual… …………………………………………………………… 9 General safety and hazard warnings for all DEWETRON systems… ………………… 10 Windows updates and antivirus/security software………………………………………… 13 Problematic network stacks… ……………………………………………………………… 13 Environmental Considerations… …………………………………………………………… 13 Blockdiagram of the internal signal processing… ………………………………………… 14 First steps……………………………………………………………………………………… 15 Main System 17 DEWE-2010 series PC instrument… ……………………………………………………… 17 System specifications………………………………………………………………………… 17 Connectors… ………………………………………………………………………………… 18 Special Combustion Analyzer I/O connectors……………………………………………… 21 A/D Conversion A1 Internal Wiring B1 CE-Certificate of conformity C1 DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 5 Table of content 6 General Information, Safety Instructions Services Training DEWETRON offers training at various offices around the world several times each year. DEWETRON headquaters in Austria have a very large and professional conference and seminar center, where training classes are conducted on a regular basis starting with sensors and signal conditioning, A/D technology and software operation. For more information about training services, please visit: http://www.dewetron.com/support/training Dewetron Inc. in the USA also has a dedicated training facility connected to its headquarters, located in Rhode Island. For more information about training services in the US, please visit: http://www.dewamerica.com/support/training Calibration Every instrument needs to be calibrated at regular intervals. The standard norm across nearly every industry is annual calibration. Before your DEWETRON data acquisition system is delivered, it is calibrated at our DEWETRON headquater. Each of this system is delivered with a certificate of compliance with our published specifications. Detailed calibration reports from our calibration system are available for purchase with each order. We retain them for at least one year, so calibration reports can be purchased for up to one year after your system was delivered. Support DEWETRON has a team of people ready to assist you if you have any questions or any technical difficulties regarding the system. For any support please contact your local distributor first or DEWETRON directly. For Asia and Europe, please contact: For the Americas, please contact: DEWETRON Ges.m.b.H. Parkring 4 A-8074 Graz-Grambach AUSTRIA Tel.: +43 316 3070 Fax: +43 316 307090 Email: [email protected] Web: http://www.dewetron.com DEWETRON, Inc. 10 High Street, Suite K Wakefield, RI 02879 U.S.A. Tel.: +1 401 284 3750 Toll-free: +1 877 431 5166 Fax: +1 401 284 3755 Email: [email protected] Web: http://www.dewamerica.com The telephone hotline is available Monday to Friday between 08:00 and 17:00 CET (GMT +1:00) The telephone hotline is available Monday to Friday between 08:00 and 17:00 GST (GMT -5:00) Service/repairs The Team of DEWETRON also performs any kinds of repairs to your system to assure a safe and proper operation in future. For information regarding service and repairs please contact your local distributor first or DEWETRON directly. DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 7 Notice The information contained in this document is subject to change without notice. DEWETRON elektronische Messgeraete Ges.m.b.H. (DEWETRON) shall not be liable for any errors contained in this document. DEWETRON MAKES NO WARRANTIES OF ANY KIND WITH REGARD TO THIS DOCUMENT, WHETHER EXPRESS OR IMPLIED. DEWETRON SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DEWETRON shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document or the use of the information in this document. Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and service office. Restricted Rights Legend Use austrian law for duplication or disclosure. DEWETRON GesmbH Parkring 4 A-8074 Graz-Grambach / Austria Printing History Please refer to the page bottom for printing version. Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H. This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners. 8 Safety instructions Safety symbols in the manual Indicates hazardous voltages. WARNING Calls attention to a procedure, practice, or condition that could cause bodily injury or death. CAUTION Calls attention to a procedure, practice, or condition that could possibly cause damage to equipment or permanent loss of data. WARNINGS The following general safety precautions must be observed during all phases of operation, service, and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customer’s failure to comply with these requirements. All accessories shown in this document are available as option and will not be shipped as standard parts. For safety reasons max. 50 V may be applied to the BNC input-connectors! Refer to the regulation of maximum allowable touch potential. DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 9 Safety instructions Your safety is our primary concern! Please be safe! General safety and hazard warnings for all DEWETRON systems Use this system under the terms of the specifications only to avoid any possible danger. Maintenance will be executed by qualified staff only. During the use of the system, it might be possible to access another parts of a more comprehensive system. Please read and follow the safety instructions provided in the manuals of all other components regarding warning and security advices for using the system. With this product, only use the power cable delivered or defined for the host country. DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a voltage supply unit. The system is grounded via a protective conductor in the power supply cord. To avoid electric shocks, the protective conductor has to be connected with the ground of the power network. Before connecting the input or output connectors of the system, make sure that there is a proper grounding to guarantee potential free usage. For countries, in which there is no proper grounding, please refere to your local legally safety regulations for safety use. DC systems: Every DC system has a grounding connected to the chassis (yellow/green safety banana plug). Please note the characteristics and indicators on the system to avoid fire or electric shocks. Before connecting the system, please carefully read the corresponding specifications in the product manual. The inputs are not, unless otherwise noted (CATx identification), for connecting to the main circuit of category II, III and IV. The power cord separates the system from the power supply. Do not block the power cord, since it has to be accessible for the users. DO NOT use the system if equipment covers or shields are removed. If you assume the system is damaged, get it examined by authorised personnel only. Any use in wet rooms, outdoors or in adverse environmental condition is not allowed! Adverse environmental conditions are: Moisture or high humidity Dust, flammable gases, fumes or dissolver Thunderstorm or thunderstorm conditions (except assembly PNA) Electrostatic fields, et cetera. The measurement category can be adjusted depending on module configuration. Any direct voltage output is protected with a fuse against short cut and reverse-polarity, but is NOT galvanically isolated (except it is explicit marked on the system). The system must be connected and operated to an earthed wall socket at the AC mains power supply only (except for DC systems). Any other use than described above may damage your system and is attended with dangers like shortcut, fire or electric shocks. The whole system must not be changed, rebuilt or opened (except for changing DAQ, DAQP, PAD modules). 10 Safety instructions If you assume a more riskless use is not provided anymore, the system has to be rendered inoperative and should be protected against inadvertent operation. It is assumed that a more riskless operation is not possible anymore, if the system is damaged obviously or causes strange noises. the system does not work anymore. the system has been exposed to long storage in adverse environmental. the system has been exposed to heavy shipment strain. DO NOT touch any exposed connetors or components if they are live wired. The use of metal bare wires is not allowed. There is a risk of short cut and fire hazard! Warranty void if damages caused by disregarding this manual. For consequential damages NO liability will be assumed! Warranty void if damages to property or persons caused by improper use or disregarding the safety instructions. Unauthorized changing or rebuilding the system is prohibited due to safety and permission reasons (CE). Exception: changing modules like DAQ, DAQP or PAD. The assembly of the system is equivalent to protection class I. For power supply, only the correct power socket of the public power supply must be used, except the system is DC powered. Be careful with voltages >25 VAC or >35 VDC! These voltages are already high enough in order to get a perilous electric shock by touching the wiring. The product heats during operation. Make sure there is adequate ventilation. Ventilation slots must not covered! Only fuses of the specified type and nominal current may be used. The use of patched fuses is prohibited. Prevent using metal bare wires! Risk of short cut and fire hazard! DO NOT use the system before, during or shortly after a thunderstorm (risk of lightning and high energy overvoltage). An advanced range of application under certain conditions is allowed with therefore designed products only. For details please refer to the specifications. Make sure that your hands, shoes, clothes, the floor, the system or measuring leads, integrated curcuits and so on, are dry. DO NOT use the system in rooms with flammable gases, fumes or dust or in adverse environmental conditions. Avoid operation in the immediate vicinity of: high magnetic or electromagnetic fields transmitting antennas or high-frequency generators For exact values please refere to enclosed specifications. Use measurement leads or measurement accessories aligned to the specification of the system only. Fire hazard in case of overload! Do not switch on the system after transporting it from a cold into a warm room and vice versa. The thereby created condensation may damage your system. Acclimatise the system unpowered to room temperature. Do not disassemble the system! There is a high risk of getting a perilous electric shock. Capacitors still might charged, even the system has been removed from the power supply. The electrical installations and equipments in industrial facilities must be observed by the security regulations and insurance institutions. DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 11 Safety instructions The use of the measuring system in schools and other training facilities must be observerd by skilled personnel. The measuring systems are not designed for use at humans and animals. Please contact a professional if you have doubts about the method of operation, safety or the connection of the system. Please be careful with the product. Shocks, hits and dropping it from already lower level may damage your system. For exact values please refere to enclosed specifications. Please also consider the detailed technical reference manual as well as the security advices of the connected systems. This product has left the factory in safety-related flawless and proper condition. In order to maintain this condition and guarantee safety use, the user has to consider the security advices and warnings in this manual. EN 61326-3-1:2008 IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as described for industrial locations in IEC 61000-6-2 or defined in 3.7 of IEC 61326-1. Equipment and systems intended for use in other electromagnetic environments, for example, in the process industry or in environments with potentially explosive atmospheres, are excluded from the scope of this product family standard, IEC 61326-3-1. Devices and systems according to IEC 61508 or IEC 61511 which are considered as “operationally welltried”, are excluded from the scope of IEC 61326-3-1. Fire-alarm and safety-alarm systems, intended for protection of buildings, are excluded from the scope of IEC 61326-3-1. 12 General Information CAUTION The system BIOS is protected by password. Any change in the BIOS may cause a system crash. When the system is booting, do not press ESC-button on keyboard. This may clear the BIOS settings and cause system faults. Any change in the file structure as deleting or adding files or directories might cause a system crash. Before installing software updates contact DEWETRON or your local distributor. Use only software packages which are released by DEWETRON. Further informations are also available in the internet (http://www.dewetron.com). After power off the system wait at least 10 seconds before switching the system on again. Otherwise the system may not boot correct. This prolongs also the life of all system components. Windows updates and antivirus/security software Before installing Windows software updates consult with DEWETRON for compatibility guidance. Please also keep in mind that the use of any antivirus or other security software may slow down your system and may cause data loss. Problematic network stacks Often intrusive IT software or network processes can interfere with the primary function of the DEWETRON system: to record data. Therefore we recommend strongly against the installation of IT/MIS software and running their processes on any DEWETRON data acquisition system, and cannot guarantee the performance of our systems if they are so configured. Environmental Considerations Information about the environmental impact of the product. Product End-of-Life Handling Observe the following guidelines when recycling a DEWETRON system: System and Components Recycling Production of these components required the extraction and use of natural resources. The substances contained in the system could be harmful to your health and to the environment if the system is improperly handled at it's end of life! Please recycle this product in an appropriate way to avoid an unnecessary pollution of the environment and to keep natural resources. This symbol indicates that this system complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). Please find further informations about recycling on the DEWETRON web site www.dewetron.com Restriction of Hazardous Substances This product has been classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. This product is known to contain lead. DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 13 Signal processing Blockdiagram of the internal signal processing AC or DC input Power supply USB and FireWire power supply Motherboard/CPU-board Measurement boards (DEWE-ORION, ...) PCI boards (USB, FireWire, ...) USB, FireWire, Ethernet (on-board) CPU RAM onboard VGA RS-232 +12V, GND, -12V DC/DC converter DAQ-Motherboard DAQ-Modules 14 First steps First steps 1 Power-on your system. 3 2 Connect your sensors to the system. Run DEWESoft usually via "Start" >"Programs" > "Dewetron" > "DEWESoft x.x" > "DEWESoft x.x" 4 Start recording your data! DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 15 First steps Notes 16 Main System Main System DEWE-2010 series PC instrument Portable data acquisition system Up to 16 channels with isolation (in conjunction with DEWE-DAQ modules) Up to 256 channels with external expansion racks A/D converter specs see appendix A System specifications DEWE-2010 Power supply: please select! Operating temperature: Storage temperature: Humidity (operating): Vibration: Shock: Dimensions (W x H x D): Weight: Dimensions* � 300 W AC power supply ‘FSP300-601U’ � AC/DC multi power supply ‘NET-202 + Accu’ for details see next pages -5 °C to 50 °C (standard) -20 °C to +70 °C 10 % to 80 %, non condensing 5 % to 95 %, rel. humidity MIL-STD 810F 514.5 procedure I operating test procedure frequency range: 5 to 200 to 5 Hz; 5 x 12 min each direction displacement amplitude ±3.5 mm (5 to 8.45 Hz) acceleration amplitude 1 g (8.45 to 92 Hz) displacement amplitude 92 to 113 Hz: ±0.029 mm acceleration amplitude 1.5 g (113 to 200 Hz) MIL-STD 810F 516.5 procedure I non operating test procedure ½ sinus 11 ms 10 g, 3 shocks positive, 3 shocks negative approx. 410 x 288 x 205 mm (16.1 x 11.3 x 8.1 in.) typ. 9.5 kg (19 lbs), depending on configuration 410 302 288 302 288 220 1 0 DEWE-2010 ROM * Dimensions in mm (1 inch = 25.4 mm) 245 DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 17 Main System Connectors Connector overview: 1. 2. 3. 4. 5. 6. 4, 5 3 Keyboard connector RS-232 interface connectors (2x) USB interface connectors (2x) VGA connector Power supply internal rack (inside system, not shown) 7. Combustion analyzer connectors (optional) 2 Typical DEWE-2010 rear view Power supply connector 1 7 Note: The location of the connectors might vary from system to system and depends on system configuration Power supply connector The system fuse for AC power supply is located between connector and power switch. If the system doesn’t work after switching on, disconnect the power cord and check the fuse. 300W AC power supply 300 W AC power supply Input: Input range: Input frequency: Max. input current: Output: Output power: Output voltages: FSP300-601U 100 to 240 VAC (auto selecting) 50 / 60 Hz 3 A to 6 A 300 W max. +3.3 V (max. 20 A)* +5 V (max. 25 A)* +12 V (max. 16 A) +5 Vsb (max. 2 A) -5 V (max. 0.3 A) -12V (max. 0.8 A) Note: The max. load of +3.3 V and +5 V together is 157 W, otherwise power supply will be damaged. ATX Power Switch Fuse (100 .. 240 V / 3.15 A T) AC connector Power on / off 18 Main System AC/DC multi power supply AC/DC Power supply NET-202 + Accu Input: AC input: DC and battery input: Max. input current: Input power: Input voltage priority: Battery type: Output: Output power: Output voltages: Power LED: dim green: bright green: orange: red: 90 to 260 VAC / 45 to 400 Hz 10 to 32 VDC 3.5 A (230 VAC) Startup peak up to 25 A 160 W 1. AC voltage 2. DC voltage 3. Battery NiCd, 24 VDC, 600 mAh 160 W +5 V (max. 20 A) +12 V (max. 5 A) -5 V (max. 0.3 A) -12 V (max. 0.4 A) AC and / or DC connected to system, system powered off AC and / or DC connected to system, system powered on system powered on, working via accu starts 30 sec. before accu is getting low together with beep signal Power on / off Fuse (100 .. 240 V / 3.15 A T) AC power supply connector DC power supply connector DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 19 Main System Keyboard connector The keyboard connector is designed to use the DEWE-2010 system keyboard as well as standard keyboards with the standard 5-pin DIN connector. Pin assignment 1: Keyboard CLK 2: Keyboard DATA 7 6 3 1 3: Mouse DATA 5 4 4: Keyboard and Mouse GND 8 2 5: Keyboard Vcc 8-pin DIN connector Schematic 6: Mouse Vcc 7: Mouse CLK 8: Not connected USB interface connectors (Universal Serial Bus) The USB interface connectors meets standard USB pin assignment. RS-232 interface connector (COM1) The RS-232 interface connector (male) is located on the left side of the DEWE-2010. It is configured as standard RS-232 interface COM 1 and can be used for mouse or other peripheral units. 1 2 3 4 5 9-pin SUB-D connector (male) 6 7 8 9 Schematic VGA connector Pin assignment 1: DCD (Data Carrier Detector) 2: RD (Received Data) 3: TD (Transmitted Data) 4: DTR (Data Terminal Ready) 5: GND (Ground) 6: DSR (Data Set Ready) 7: RTS (Request To Send) 8: CTS (Clear To Send) 9: RI (Ring Indicator) The VGA connector offers the possibility to connect an external CRT or other standard VGA displays to the system. 5 4 3 2 1 10 9 8 7 6 15-pin mini-SUB-D connector (male) 20 15 14 13 12 11 Schematic Pin assignment 1: Red video 2: Green video / Sync on green 3: Blue video 4: 5: 6: Red video ground 7: Green video ground 8: Blue video ground 9: 10: Ground 11: Ground 12: Data line 13: H-Sync / HV-Sync 14: V-Sync 15: Clock line Main System Ethernet connector The DEWE-2010 system supports 10/100 BaseT Ethernet with standard RJ45 connector. Power-on button The power-on button has to be used to switch on the system. It only works when the main power switch is on. Power supply backplane / cooling fan The AMP connector is the internal power supply connection to the internal rack and the cooling fan, mounted on the backplane of the DEWE-2010 system. 6-pin AMP connector 3 2 1 6 5 4 Schematic Pin assignment 1: +12 V 2: GND 3: +5 V 4: -12 V 5: GND (EPAD supply) 6: +12 V (EPAD supply) Ground connectors For some kind of measurements, it’s necessary to give the system an additional ground connection. Special Combustion Analyzer I/O connectors The Combustion Analyzer requires several special input signals to work. Please refer to appendix B (wirings) for details. CDM CDM TRIG CA AUX1 AUX2 Signal output 2 (wiring according to appendix B) Signal output 1 (wiring according to appendix B) CA Connector ‘Zero position’ signal (upper death point signal), TTL level input CDM - angle position signal from high resolution encoders, TTL level input Crank Angle Sensor DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 21 Main System Notes 22 A/D Conversion A/D & D/A Conversion A/D Conversion Please find information about the A/D conversion in the attached DEWE-ORION series manual. The latest version of the manual can be downloaded from: http://download.dewetron.com/dl/components/adboards Informations regarding different manufacturer's see the corresponding D/A card manual. DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 A1 A/D & D/A Conversion Notes A2 Internal Wiring Internal Wiring 16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-DE-x Rear view W7 5 = 5 V output; 330 kHz filter 10 = 10 V output; 330 kHz filter GND +15 V ORION -15 V ORION W1 CH 0 W10 Front view CH 1 W11 16 channels single ended analog output (output resistance 15 Ohm) Please find the pin-assignment on the next page! W8 CH 2 CH 3 5 V ORION Ext. CLK Ext. TRIG DGND ORION Ext. CLK 2 OUT Ext. CLK 1 OUT (CAMERA TRIGGER) W9 CH 4 CH 5 DGND ORION W5 CH 6 CH 7 Terminate RS-485 Connect GND to GNDP W3 Connect +12 V to +V (pin 6) W4 Terminate RS-485 W5 Connect chassis to GND W6 Connect chassis to GND W7 Connect chassis to GND W8 Activate ORION RS-485 (A) W9 Activate ORION RS-485 (B) W1 16x GND 16 x analog OUT (resistance 50 Ohm) GND W2 CH 8 CH 9 CH 10 CH 11 Activate analog output 0 on CH 14 W11 Activate analog output 1 on CH 15 W10 CH 12 Note: If you connect signals to these contacts you have to open the solder jumpers W10 and W11 first! CH 13 CH 14 Connection to CH14 (pin 7) Indicator +9 V -9 V CH 15 Connection to CH15 (pin 7) 1 2 3 4 5 W4 W3 +V +12 V GNDP -12 V -V GNDC GNDC TX RX 1 2 3 4 5 6 RS-232 9-pin SUB-D pin assignment: A (RS-485) GNDC B (RS-485) GNDP +V +12 V -12 V -V RS-485 RS-485 W2 6 7 8 9 GND POWER W6 POWER DM DP GNDC RX TX GNDC B B A A USB RES GND 7 8 9 Module input (±5 V) RS-485 (A) RS-485 (B) GND +9 V power supply +12 V power (default) / +V sensor supply Module output (from A/D board) -V sensor supply -9 V power supply The 16 slot DEWE-MOTHERBOARD receives the ±12 VDC power supply via a DC/DC converter from the internal power supply. DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 B1 Internal Wiring Analog output connector pin-assignment Connector for DEWE-ORION-1616 cards +15 V AGND AGND AGND AGND AGND AGND AGND AGND AGND AISENSE2 AGND AGND AGND AGND AGND AGND AGND AISENSE1 AGND DI8/DO0 DI9/DO1 DI10/DO2 DI11/DO3 DI12/DO4 DI13/DO5 DI14/DO6 DI15/DO7 +5 V DGND DGND +5 V DGND DGND 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Connector for DEWE-ORION-1624 cards -15 V AGND AGND CH15+ CH14+ CH13+ CH12+ CH11+ CH10+ CH9+ CH8+ CH7+ CH6+ CH5+ CH4+ CH3+ CH2+ CH1+ CH0+ AGND DI0/Source(0) DI1/Gate(0) DI2/AUX_U_D(0) DI3/Source(1) DI4/Gate(1) DI5/AUX_U_D(1) RS-485A RS-485B DI 6 DI 7 EXT_CLK EXT_Trigger EXT_CLK1 EXT_CLK2 +15V AGND AGND CH. 15CH. 14CH. 13CH. 12CH. 11CH. 10CH. 9CH. 8CH. 7CH. 6CH. 5CH. 4CH. 3CH. 2CH. 1CH. 0AGND NC. NC. NC. NC. NC. NC. NC. NC. +5 V DGND DGND +5 V DGND DGND 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 -15 V AGND AGND CH. 15+ CH. 14+ CH. 13+ CH. 12+ CH. 11+ CH. 10+ CH. 9+ CH. 8+ CH. 7+ CH. 6+ CH. 5+ CH. 4+ CH. 3+ CH. 2+ CH. 1+ CH. 0+ AGND NC. NC. NC. NC. NC. NC. RES.* RES.* RES.* RES.* RES.* EXT-TRIGGER SAMPLE CLOCK NC. * DONT CONNECT 68-pin high density connector 68-pin high density connector 16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-NI-x-U 5 = 5 V output; 330 kHz filter 10 = 10 V output; 330 kHz filter Connector for National InstrumentsTM A/D cards DGND DGND PFI 8/P2.0 PFI 7/P1.7 PFI 15/P2.7 PFI 13/P2.5 PFI 4/P1.4 PFI 3/P1.3 PFI 2/P1.2 DGND PFI 10/P2.2 PFI 11/P2.3 P0.3 P0.7 P0.2 DGND P0.5 P0.0 DGND AO GND AO GND AI GND AI 7 AI 14 AI GND AI 5 AI 12 AI Sense AI 11 AI GND AI 2 AI 9 AI GND AI 0 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 PFI 14/P2.6 PFI 112/P2.4 PFI 9/P2.1 DGND PFI 6/P1.6 PFI 5/P1.5 DGND +5 V DGND PFI 1/P1.1 PFI 0/P1.0 DGND DGND +5 V DGND P0.6 P0.1 DGND P0.4 APFI 0 AO 1 AO 0 AI 15 AI GND AI 6 AI 13 AI GND AI 4 AI GND AI 3 AI 10 AI GND AI 1 AI 8 68-pin high density connector B2 USB interface on-board Rear view W7 W1 DGND 16 channels single ended analog output (output resistance 15 Ohm) Please find the pin-assignment on the next page! Analog OUT Ch. 1 Analog OUT Ch. 0 Terminate RS-485 Connect GND to GNDP W3 Connect +12 V to +V (pin 6) W4 Terminate RS-485 W5 Connect chassis to GND W6 Connect chassis to GND W7 Connect chassis to GND W1 DGND GND W2 CE-Certificate of conformity CE-Certificate of conformity Manufacturer: DEWETRON Elektronische Messgeraete Ges.m.b.H. Address: Parkring 4 A-8074 Graz-Grambach Austria Tel.: +43 316 3070 0 Fax: +43 316 3070 90 e-mail: [email protected] http://www.dewetron.com Name of product: DEWE-2010 Kind of product: Data acquisition instrument The product meets the regulations of the following EC-directives: 73/23/EEC "Directive on the approximation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits amended by the directive 93/68/EEC" 89/336/EEC "Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility amended by the directives 91/263/EEC, 92/31/ EEC, 93/68/EEC and 93/97/EEC The accordance is proved by the observance of the following standards: L V E M C Safety IEC/EN 61010-1:1992/93 IEC/EN 61010-2-031 IEC 61010-1:1992/300 V CATIII Pol. D. 2 IEC 1010-2-031 Emissions EN 61000-6-4 EN 55011 Class B Immunity EN 61000-6-2 Group standard Graz, October 14, 2008 Place / Date of the CE-marking Dipl.-Ing. Roland Jeutter / Managing director DE-M040408E • DEWE-2010 • Technical Reference Manual • Printing version 2.1.2 • September 1st, 2010 C1 Notes C2 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Portable
- Up to 256 channels
- Modular design
- Various input types
- DEWESoft software
- Calibration
- Support
- Warranty
Frequently asked questions
The DEWE-2010 is a data acquisition system used for measuring different physical and/or electrical sizes, depending on the model or configuration. See the manual for more information.
This product uses safety banana plugs, BNC connectors, D-SUB connectors, thermocouple connectors, BINDER® connectors, or LEMO® connectors, depending on the model or configuration.
Each DEWE-2010 system is calibrated at the factory and comes with a certificate of compliance. For information on calibration services, contact DEWETRON or your local distributor.