Dewetron DEWE-2011 is a portable data acquisition system designed for versatile measurement tasks. It offers up to 256 channels with external expansion racks and supports various data acquisition modules. The system is equipped with a powerful PC, providing a user-friendly interface and advanced analysis capabilities. Dewetron DEWE-2011 is built for demanding applications in various industries, from research and development to production and testing.
PDF
Download
Document
Advertisement
Advertisement
Technical Reference Content General Information, Safety Instructions 5 Warranty Information ……………………………………………………………………… 5 Support ……………………………………………………………………………………… 5 Printing History ……………………………………………………………………………… 5 Safety symbols in the manual …………………………………………………………… 6 Safety instructions for all DEWETRON systems ……………………………………… 7 Environmental Considerations …………………………………………………………… 8 Main System 9 DEWE-2011 series PC instrument ……………………………………………………… 9 System specifications ……………………………………………………………………… 9 Connectors ………………………………………………………………………………… 10 A/D & D/A Conversion A1 Internal Wiring B1 Declaration of conformity C1 DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 3 Technical Reference 4 General Information, Safety Instructions Notice The information contained in this document is subject to change without notice. DEWETRON elektronische Messgeraete Ges.m.b.H. (DEWETRON) shall not be liable for any errors contained in this document. DEWETRON MAKES NO WARRANTIES OF ANY KIND WITH REGARD TO THIS DOCUMENT, WHETHER EXPRESS OR IMPLIED. DEWETRON SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DEWETRON shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document or the use of the information in this document. Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and service office. Support For any support please contact your local distributor first or DEWETRON directly. For Asia and Europe, please contact: For the Americas, please contact: DEWETRON Ges.m.b.H. Parkring 4 A-8074 Graz-Grambach AUSTRIA Tel.: +43 316 3070 Fax: +43 316 307090 Email: [email protected] Web: http://www.dewetron.com DEWETRON, Inc. 10 High Street, Suite K Wakefield, RI 02879 U.S.A. +1 401 284 3750 Tel.: Toll-free: +1 877 431 5166 Fax: +1 401 284 3755 Email: [email protected] Web: http://www.dewamerica.com The telephone hotline is available Monday to Friday between 08:00 and 17:00 CET (GMT +1:00) The telephone hotline is available Monday to Friday between 08:00 and 17:00 GST (GMT -5:00) Restricted Rights Legend Use austrian law for duplication or disclosure. DEWETRON GesmbH Parkring 4 A-8074 Graz-Grambach / Austria Printing History Please refer to the page bottom for printing version. Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H. This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners. DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 5 Safety instructions Safety symbols in the manual Indicates hazardous voltages. WARNING Calls attention to a procedure, practice, or condition that could cause bodily injury or death. CAUTION Calls attention to a procedure, practice, or condition that could possibly cause damage to equipment or permanent loss of data. WARNINGS The following general safety precautions must be observed during all phases of operation, service, and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customer’s failure to comply with these requirements. All accessories shown in this document are available as option and will not be shipped as standard parts. For safety reasons max. 50 V may be applied to the BNC input-connectors! Refer to the regulation of maximum allowable touch potential. 6 Safety instructions Safety instructions for all DEWETRON systems The DEWETRON data acquisition systems may only be installed by experts. Read your manual before operating the system. Observe local laws when using the instrument. Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth terminal), a non interruptible safety earth ground must be provided from the mains power source to the product input wiring terminals or supplied power cable. DO NOT operate the product in an explosive atmosphere or in the presence of flammable gases or fumes and do not bring the system in contact with water. DO NOT operate damaged equipment: Whenever it is possible that the safety protection features built into this product have been impaired, either through physical damage, excessive moisture, or any other reason, REMOVE POWER and do not use the product until safe operation can be verified by service-trained personnel. If necessary, return the product to a DEWETRON sales and service office for service and repair to ensure that safety features are maintained. Keep away from live circuits: Operating personnel must not remove equipment covers or shields. Procedures involving the removal of covers or shields are for use by service-trained personnel only. Under certain conditions, dangerous voltages may exist even with the equipment switched off. To avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal unless you are qualified to do so. No modifications are allowed at the instrument. The fuse in the power module has to be replaced by the same type. For continued protection against fire, replace the line fuse(s) only with fuse(s) of the same voltage and current rating and type. DO NOT use repaired fuses or short-circuited fuse holder labels and print on the power module may not be removed. DO NOT service or adjust alone. Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present. DO NOT substitute parts or modify equipment: Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the product. Return the product to a DEWETRON sales and service office for service and repair to ensure that safety features are maintained. Before opening the instrument (experts only) or exchanging the fuse in the power module disconnect power! Don’t touch internal wiring! Don’t use higher supply voltage than specified and take care of the correct polarity, otherwise the system will be damaged! Use only original plugs and cables for harnessing. Install filler-panels in unused slots. The power-cable and -connector serve as Power-Breaker. The cable must not exceed 10 feet, disconnect function must be possible without tools. Keep the ventilation slots free and check them frequently to avoid an overheating of the system. The cleaning interval of the filter pads depends on the environmental conditions. Safety of the operator and the unit depend on following these rules. DEWETRON is not responsible for any damage or injury that could result from improper connection or misuse! DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 7 General Information CAUTION The system BIOS is protected by password. Any change in the BIOS may cause a system crash. When the system is booting, do not press ESC-button on keyboard. This may clear the BIOS settings and cause system faults. Any change in the file structure as deleting or adding files or directories might cause a system crash. Before installing software updates contact DEWETRON or your local distributor. Use only software packages which are released by DEWETRON. Further informations are also available in the internet (http://www.dewetron.com). After power off the system wait at least 10 seconds before switching the system on again. Otherwise the system may not boot correct. This prolongs also the life of all system components. Environmental Considerations Information about the environmental impact of the product. Product End-of-Life Handling Observe the following guidelines when recycling a DEWETRON system: System and Components Recycling Production of these components required the extraction and use of natural resources. The substances contained in the system could be harmful to your health and to the environment if the system is improperly handled at it's end of life! Please recycle this product in an appropriate way to avoid an unnecessary pollution of the environment and to keep natural resources. This symbol indicates that this system complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). Please find further informations about recycling on the DEWETRON web site www.dewetron.com Restriction of Hazardous Substances This product has been classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. This product is known to contain lead. 8 Main System Main System DEWE-2011 series PC instrument Portable data acquisition system Up to 8 MDAQ-SUB-x-BNC modules (DEWE-2011-B1) Up to 4 MDAQ-SUB-x-D modules (DEWE-2011-B2) Up to 256 channels with external expansion racks A/D converter specs see appendix A System specifications Power supply: Operating temperature: Storage temperature: Humidity (operating): Vibration: Shock: Dimensions (W x H x D): Weight: Warning MDAQ-AAF4-5-BU � MDAQ-FILT-10-S1 � MDAQ-FILT-10 � � � � � � � � � MDAQ-FILT-5-BU-S1 � � � � � � � � � MDAQ-FILT-5-BE � � � � � � � � � MDAQ-FILT-5-BU � � � � � � � � � MDAQ-BASE-10 � � � � � � � � � MDAQ-BASE-5 � MDAQ-SUB-STG � MDAQ-SUB-BRIDGE � MDAQ-SUB-ACC-A-x � MDAQ-SUB-ACC-x � MDAQ-SUB-V-200 MDAQ-V-100 please select! MDAQ-V-10 Channel 0 to 7 Channel 8 to 15 Channel 16 to 23 Channel 24 to 31 Channel 32 to 39 Channel 40 to 47 Channel 48 to 55 Channel 56 to 63 MDAQ-DIRECT DEWE-2011 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 300 W AC power supply ‘FSP300-601U’ � AC/DC multi power supply ‘NET-202 + Accu’ for details see next pages -5 °C to 50 °C (standard) -20 °C to +70 °C 10 % to 80 %, non condensing 5 % to 95 %, rel. humidity MIL-STD 810F 514.5 procedure I operating test procedure frequency range: 5 to 200 to 5 Hz; 5 x 12 min each direction displacement amplitude ±3.5 mm (5 to 8.45 Hz) acceleration amplitude 1 g (8.45 to 92 Hz) displacement amplitude 92 to 113 Hz: ±0.029 mm acceleration amplitude 1.5 g (113 to 200 Hz) MIL-STD 810F 516.5 procedure I non operating test procedure ½ sinus 11 ms 10 g, 3 shocks positive, 3 shocks negative approx. 410 x 288 x 205 mm (16.1 x 11.3 x 8.1 in.) typ. 9.5 kg (19 lbs), depending on configuration For safety reasons max. 50 V may be applied to modules with BNC input-connectors! Refer to the regulation of maximum allowable touch potential. DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 9 Main System Dimensions* 410 302 288 302 288 205 1 0 DEWE-2010 ROM * Dimensions in mm (1 inch = 25.4 mm) 228 Connectors Connector overview: 11 10 9 8 7 2 1 3 4 Typical DEWE-2011-B1 rear view 4 5 6 5 Ground connector Digital I/O connector Audio connectors RS-232 interface connectors USB interface connectors Main power switch Power-on button and power supply connector 8. Keyboard connector 9. Analog input connectors 10. EPAD connector 11. VGA connector 12. Power supply internal rack (inside system, not shown) 1. 2. 3. 4. 5. 6. 7. Note: The location of the connectors might vary from system to system and depends on system configuration Power supply connector The system fuse for AC power supply is located between connector and power switch. If the system doesn’t work after switching on, disconnect the power cord and check the fuse. 300W AC power supply 300 W AC power supply Input: Input range: Input frequency: Max. input current: Output: Output power: Output voltages: 10 FSP300-601U 100 to 240 VAC (auto selecting) 50 / 60 Hz 3 A to 6 A 300 W max. +3.3 V (max. 20 A)* +5 V (max. 25 A)* +12 V (max. 16 A) +5 Vsb (max. 2 A) -5 V (max. 0.3 A) -12V (max. 0.8 A) Main System Note: The max. load of +3.3 V and +5 V together is 157 W, otherwise power supply will be damaged. ATX Power Switch Fuse (250 V / 1 A T 110 V / 3.15 A T) AC connector Power on / off AC/DC multi power supply AC/DC Power supply NET-202 + Accu Input: AC input: DC and battery input: Max. input current: Input power: Input voltage priority: Battery type: Output: Output power: Output voltages: Power LED: dim green: bright green: orange: red: 90 to 260 VAC / 45 to 400 Hz 10 to 32 VDC 3.5 A (230 VAC) Startup peak up to 25 A 160 W 1. AC voltage 2. DC voltage 3. Battery NiCd, 24 VDC, 600 mAh 160 W +5 V (max. 20 A) +12 V (max. 5 A) -5 V (max. 0.3 A) -12 V (max. 0.4 A) AC and / or DC connected to system, system powered off AC and / or DC connected to system, system powered on system powered on, working via accu starts 30 sec. before accu is getting low together with beep signal Power on / off Fuse (250 V / 1 A T; 110 V / 3.15 A T) AC power supply connector DC power supply connector DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 11 Main System Keyboard connector The keyboard connector is designed to use the DEWE-2011 system keyboard as well as standard keyboards with the standard 5-pin DIN connector. Pin assignment 1: Keyboard CLK 2: Keyboard DATA 7 6 3 1 3: Mouse DATA 5 4 4: Keyboard and Mouse GND 2 8 5: Keyboard Vcc 8-pin DIN connector Schematic 6: Mouse Vcc 7: Mouse CLK 8: Not connected USB interface connectors (Universal Serial Bus) The USB interface connectors meets standard USB pin assignment. RS-232 interface connector (COM1) The RS-232 interface connector (male) is located on the left side of the DEWE-2011. It is configured as standard RS-232 interface COM 1 and can be used for mouse or other peripheral units. 1 2 3 4 5 6 7 8 9 9-pin SUB-D connector (male) Schematic VGA connector Pin assignment 1: DCD (Data Carrier Detector) 2: RD (Received Data) 3: TD (Transmitted Data) 4: DTR (Data Terminal Ready) 5: GND (Ground) 6: DSR (Data Set Ready) 7: RTS (Request To Send) 8: CTS (Clear To Send) 9: RI (Ring Indicator) The VGA connector offers the possibility to connect an external CRT or other standard VGA displays to the system. 5 4 3 2 1 10 9 8 7 6 15-pin mini-SUB-D connector (male) 12 15 14 13 12 11 Schematic Pin assignment 1: Red video 2: Green video / Sync on green 3: Blue video 4: 5: 6: Red video ground 7: Green video ground 8: Blue video ground 9: 10: Ground 11: Ground 12: Data line 13: H-Sync / HV-Sync 14: V-Sync 15: Clock line Main System Ethernet connector The DEWE-2011 system supports 10/100 BaseT Ethernet with standard RJ45 connector. Power-on button The power-on button has to be used to switch on the system. It only works when the main power switch is on. Power supply backplane / cooling fan The AMP connector is the internal power supply connection to the internal rack and the cooling fan, mounted on the backplane of the DEWE-2011 system. 6-pin AMP connector 3 2 1 6 5 4 Schematic Pin assignment 1: +15 V 2: GND 3: not connected 4: -15 V 5: GND (EPAD supply) 6: +12 V (EPAD supply) Ground connectors For some kind of measurements, it’s necessary to give the system an additional ground connection. DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 13 Main System Notes 14 A/D & D/A Conversion A/D & D/A Conversion A/D Conversion Detailed information about the A/D card are not included in this manual. For detailed information see the manufacturer’s A/D card manual. D/A Conversion Detailed information about the D/A card are not included in this manual. For detailed information see the manufacturer’s D/A card manual. DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 A1 A/D & D/A Conversion Notes A2 Internal Wiring Internal Wiring Please find information about the MDAQ amplifiers in the attached MDAQ-INT series modules manual. The latest version of the manual can be downloaded from: http://www.dewetron.com/download/index.php?search=MDAQ&catkey=manuals-amplifiers DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 B1 Internal Wiring Notes B2 Declaration of conformity Following products are in conformity with EN50081 (Electromagnetic compatibility, generic emission standard for light and heavy industry) and EN50082 (Electromagnetic compatibility, generic immunity standard for light and heavy industry): DEWE-2000 / DEWE-2010 / DEWE-2500 series DEWE-3000 / DEWE-3010 / DEWE-3020 series DEWE-4000 / DEWE-4010 series DEWE-200 series DEWE-500 series DEWE-5000 series DEWE-600 series DEWE-800 series DEWE-900 series DEWE-BOOK series DEWE-RACK series DAQ / MDAQ modules series PAD / EPAD modules series Note: Enhanced EMC specifications are achieved when using DC power supply input. Manufacturer: DEWETRON Elektronische Messgeraete Ges.m.b.H. Parkring 4 A-8074 Graz-Grambach Austria Tel.: +43 316 3070 0 Fax: +43 316 3070 90 e-mail: [email protected] http://www.dewetron.com Graz, Nov. 15th, 2004 Ing. Herbert Wernigg Managing director DE-M051204E • DEWE-2011 • Technical Reference Manual • Printing version 1.1.0 • April 19, 2007 C1 Notes C2 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Portable data acquisition
- Up to 256 channels
- External expansion racks
- Powerful PC
- User-friendly interface
- Advanced analysis
Frequently asked questions
The operating temperature range for the DEWE-2011 is -5 °C to 50 °C (standard).
The DEWE-2011 can be powered by a 300W AC power supply 'FSP300-601U' or an AC/DC multi power supply 'NET-202 + Accu'. Refer to the manual for more information.
Yes, the keyboard connector is designed to use the DEWE-2011 system keyboard as well as standard keyboards with the standard 5-pin DIN connector.
The approximate dimensions of the DEWE-2011 are 410 x 288 x 205 mm (16.1 x 11.3 x 8.1 in.).