Dewetron DEWE-5000 is a portable data acquisition system designed for measuring various physical and electrical parameters. It features up to 256 channels and supports multiple sensor types for diverse applications in automotive, aerospace, and various other industries. The DEWE-5000 includes internal slots for DAQ modules, allowing for customized configuration for specific measurement needs.
PDF
Download
Document
Advertisement
Advertisement
Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement DEWE-5000 Technical reference manual ISO9001 www.dewetr o n .c om Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H. This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners. Preface Thank you! Thank you very much for your investment in DEWETRON's unique data acquisition systems. These are top-quality instruments which are designed to provide you years of reliable service. This guide has been prepared to help you get the most from your investment, starting from the day you take it out of the box, and extending for years into the future. This guide includes important startup notes, as well as safety notes and information about keeping your DEWETRON system in good working condition over time. We strongly suggest that you read this entire manual, especially the safety and care sections, as well as to avoid damaging your DEWETRON system. What is the DEWE-5000? This product is used for measuring of different physical and/or electrical sizes (depending on model or configuration). The connection is depending on model or configuration and takes place via safety banana plugs, BNC connectors (± 50V max.), D-SUB connectors (± 50V max.), thermocouple connectors (± 50V max.), BINDER® connectors (± 50V max.), SMB connetcors (± 50V max.), µdot connectors (± 50V max.), LEMO® connectors or RJ-45 connectors. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 3 Preface Notes 4 General Information, Safety Instructions Services Training DEWETRON offers training at various offices around the world several times each year. DEWETRON headquaters in Austria have a very large and professional conference and seminar center, where training classes are conducted on a regular basis starting with sensors and signal conditioning, A/D technology and software operation. For more information about training services, please visit: http://www.dewetron.com/support/training Dewetron Inc. in the USA also has a dedicated training facility connected to its headquarters, located in Rhode Island. For more information about training services in the US, please visit: http://www.dewamerica.com/support/training Calibration Every instrument needs to be calibrated at regular intervals. The standard norm across nearly every industry is annual calibration. Before your DEWETRON data acquisition system is delivered, it is calibrated at our DEWETRON headquater. Each of this system is delivered with a certificate of compliance with our published specifications. Detailed calibration reports from our calibration system are available for purchase with each order. We retain them for at least one year, so calibration reports can be purchased for up to one year after your system was delivered. Support DEWETRON has a team of people ready to assist you if you have any questions or any technical difficulties regarding the system. For any support please contact your local distributor first or DEWETRON directly. For Asia and Europe, please contact: For the Americas, please contact: DEWETRON Ges.m.b.H. Parkring 4 A-8074 Graz-Grambach AUSTRIA Tel.: +43 316 3070 Fax: +43 316 307090 Email: [email protected] Web: http://www.dewetron.com DEWETRON, Inc. 10 High Street, Suite K Wakefield, RI 02879 U.S.A. Tel.: +1 401 284 3750 Toll-free: +1 877 431 5166 Fax: +1 401 284 3755 Email: [email protected] Web: http://www.dewamerica.com The telephone hotline is available Monday to Friday between 08:00 and 17:00 CET (GMT +1:00) The telephone hotline is available Monday to Friday between 08:00 and 17:00 GST (GMT -5:00) Service/repairs The Team of DEWETRON also performs any kinds of repairs to your system to assure a safe and proper operation in future. For information regarding service and repairs please contact your local distributor first or DEWETRON directly. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 5 Notice The information contained in this document is subject to change without notice. DEWETRON elektronische Messgeraete Ges.m.b.H. (DEWETRON) shall not be liable for any errors contained in this document. DEWETRON MAKES NO WARRANTIES OF ANY KIND WITH REGARD TO THIS DOCUMENT, WHETHER EXPRESS OR IMPLIED. DEWETRON SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DEWETRON shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document or the use of the information in this document. Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and service office. Restricted Rights Legend Use austrian law for duplication or disclosure. DEWETRON GesmbH Parkring 4 A-8074 Graz-Grambach / Austria Printing History Please refer to the page bottom for printing version. Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H. This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners. 6 Safety instructions Safety symbols in the manual Indicates hazardous voltages. WARNING Calls attention to a procedure, practice, or condition that could cause bodily injury or death. CAUTION Calls attention to a procedure, practice, or condition that could possibly cause damage to equipment or permanent loss of data. WARNINGS The following general safety precautions must be observed during all phases of operation, service, and repair of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customer’s failure to comply with these requirements. All accessories shown in this document are available as option and will not be shipped as standard parts. For safety reasons max. 50 V may be applied to the BNC input-connectors! Refer to the regulation of maximum allowable touch potential. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 7 Safety instructions Your safety is our primary concern! Please be safe! General safety and hazard warnings for all DEWETRON systems Use this system under the terms of the specifications only to avoid any possible danger. Maintenance will be executed by qualified staff only. During the use of the system, it might be possible to access another parts of a more comprehensive system. Please read and follow the safety instructions provided in the manuals of all other components regarding warning and security advices for using the system. With this product, only use the power cable delivered or defined for the host country. DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a voltage supply unit. The system is grounded via a protective conductor in the power supply cord. To avoid electric shocks, the protective conductor has to be connected with the ground of the power network. Before connecting the input or output connectors of the system, make sure that there is a proper grounding to guarantee potential free usage. For countries, in which there is no proper grounding, please refere to your local legally safety regulations for safety use. DC systems: Every DC system has a grounding connected to the chassis (yellow/green safety banana plug). Please note the characteristics and indicators on the system to avoid fire or electric shocks. Before connecting the system, please carefully read the corresponding specifications in the product manual. The inputs are not, unless otherwise noted (CATx identification), for connecting to the main circuit of category II, III and IV. The power cord separates the system from the power supply. Do not block the power cord, since it has to be accessible for the users. DO NOT use the system if equipment covers or shields are removed. If you assume the system is damaged, get it examined by authorised personnel only. Any use in wet rooms, outdoors or in adverse environmental condition is not allowed! Adverse environmental conditions are: Moisture or high humidity Dust, flammable gases, fumes or dissolver Thunderstorm or thunderstorm conditions (except assembly PNA) Electrostatic fields, et cetera. The measurement category can be adjusted depending on module configuration. Any direct voltage output is protected with a fuse against short cut and reverse-polarity, but is NOT galvanically isolated (except it is explicit marked on the system). The system must be connected and operated to an earthed wall socket at the AC mains power supply only (except for DC systems). Any other use than described above may damage your system and is attended with dangers like shortcut, fire or electric shocks. The whole system must not be changed, rebuilt or opened (except for changing DAQ, DAQP, PAD modules). 8 Safety instructions If you assume a more riskless use is not provided anymore, the system has to be rendered inoperative and should be protected against inadvertent operation. It is assumed that a more riskless operation is not possible anymore, if the system is damaged obviously or causes strange noises. the system does not work anymore. the system has been exposed to long storage in adverse environmental. the system has been exposed to heavy shipment strain. DO NOT touch any exposed connetors or components if they are live wired. The use of metal bare wires is not allowed. There is a risk of short cut and fire hazard! Warranty void if damages caused by disregarding this manual. For consequential damages NO liability will be assumed! Warranty void if damages to property or persons caused by improper use or disregarding the safety instructions. Unauthorized changing or rebuilding the system is prohibited due to safety and permission reasons (CE). Exception: changing modules like DAQ, DAQP or PAD. The assembly of the system is equivalent to protection class I. For power supply, only the correct power socket of the public power supply must be used, except the system is DC powered. Be careful with voltages >25 VAC or >35 VDC! These voltages are already high enough in order to get a perilous electric shock by touching the wiring. The product heats during operation. Make sure there is adequate ventilation. Ventilation slots must not covered! Only fuses of the specified type and nominal current may be used. The use of patched fuses is prohibited. Prevent using metal bare wires! Risk of short cut and fire hazard! DO NOT use the system before, during or shortly after a thunderstorm (risk of lightning and high energy overvoltage). An advanced range of application under certain conditions is allowed with therefore designed products only. For details please refer to the specifications. Make sure that your hands, shoes, clothes, the floor, the system or measuring leads, integrated curcuits and so on, are dry. DO NOT use the system in rooms with flammable gases, fumes or dust or in adverse environmental conditions. Avoid operation in the immediate vicinity of: high magnetic or electromagnetic fields transmitting antennas or high-frequency generators For exact values please refere to enclosed specifications. Use measurement leads or measurement accessories aligned to the specification of the system only. Fire hazard in case of overload! Do not switch on the system after transporting it from a cold into a warm room and vice versa. The thereby created condensation may damage your system. Acclimatise the system unpowered to room temperature. Do not disassemble the system! There is a high risk of getting a perilous electric shock. Capacitors still might charged, even the system has been removed from the power supply. The electrical installations and equipments in industrial facilities must be observed by the security regulations and insurance institutions. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 9 Safety instructions The use of the measuring system in schools and other training facilities must be observerd by skilled personnel. The measuring systems are not designed for use at humans and animals. Please contact a professional if you have doubts about the method of operation, safety or the connection of the system. Please be careful with the product. Shocks, hits and dropping it from already lower level may damage your system. For exact values please refere to enclosed specifications. Please also consider the detailed technical reference manual as well as the security advices of the connected systems. This product has left the factory in safety-related flawless and proper condition. In order to maintain this condition and guarantee safety use, the user has to consider the security advices and warnings in this manual. EN 61326-3-1:2008 IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as described for industrial locations in IEC 61000-6-2 or defined in 3.7 of IEC 61326-1. Equipment and systems intended for use in other electromagnetic environments, for example, in the process industry or in environments with potentially explosive atmospheres, are excluded from the scope of this product family standard, IEC 61326-3-1. Devices and systems according to IEC 61508 or IEC 61511 which are considered as “operationally welltried”, are excluded from the scope of IEC 61326-3-1. Fire-alarm and safety-alarm systems, intended for protection of buildings, are excluded from the scope of IEC 61326-3-1. 10 General Information CAUTION The system BIOS is protected by password. Any change in the BIOS may cause a system crash. When the system is booting, do not press ESC-button on keyboard. This may clear the BIOS settings and cause system faults. Any change in the file structure as deleting or adding files or directories might cause a system crash. Before installing software updates contact DEWETRON or your local distributor. Use only software packages which are released by DEWETRON. Further informations are also available in the internet (http://www.dewetron.com). After power off the system wait at least 10 seconds before switching the system on again. Otherwise the system may not boot correct. This prolongs also the life of all system components. Windows updates and antivirus/security software Before installing Windows software updates consult with DEWETRON for compatibility guidance. Please also keep in mind that the use of any antivirus or other security software may slow down your system and may cause data loss. Problematic network stacks Often intrusive IT software or network processes can interfere with the primary function of the DEWETRON system: to record data. Therefore we recommend strongly against the installation of IT/MIS software and running their processes on any DEWETRON data acquisition system, and cannot guarantee the performance of our systems if they are so configured. Environmental Considerations Information about the environmental impact of the product. Product End-of-Life Handling Observe the following guidelines when recycling a DEWETRON system: System and Components Recycling Production of these components required the extraction and use of natural resources. The substances contained in the system could be harmful to your health and to the environment if the system is improperly handled at it's end of life! Please recycle this product in an appropriate way to avoid an unnecessary pollution of the environment and to keep natural resources. This symbol indicates that this system complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). Please find further informations about recycling on the DEWETRON web site www.dewetron.com Restriction of Hazardous Substances This product has been classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. This product is known to contain lead. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 11 Signal processing Blockdiagram of the internal signal processing AC or DC input Power supply USB and FireWire power supply Motherboard/CPU-board Measurement boards (DEWE-ORION, ...) PCI boards (USB, FireWire, ...) USB, FireWire, Ethernet (on-board) CPU RAM onboard VGA RS-232 +12V, GND, -12V DC/DC converter DAQ-Motherboard DAQ-Modules 12 Display First steps First steps 1 Power-on your system. 3 2 Connect your sensors to the system. Run DEWESoft usually via "Start" >"Programs" > "Dewetron" > "DEWESoft x.x" > "DEWESoft x.x" 4 Start recording your data! DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 13 First steps Notes 14 Table of content Content General Information, Safety Instructions 5 Training………………………………………………………………………………………… 5 Calibration……………………………………………………………………………………… 5 Support………………………………………………………………………………………… 5 Service/repairs………………………………………………………………………………… 5 Warranty Information… ……………………………………………………………………… 6 Printing History………………………………………………………………………………… 6 Safety symbols in the manual… …………………………………………………………… 7 General safety and hazard warnings for all DEWETRON systems… ………………… 8 Windows updates and antivirus/security software………………………………………… 11 Problematic network stacks… ……………………………………………………………… 11 Environmental Considerations… …………………………………………………………… 11 Blockdiagram of the internal signal processing… ………………………………………… 12 First steps……………………………………………………………………………………… 13 Main System 17 System specifications………………………………………………………………………… 17 Connectors… ………………………………………………………………………………… 18 DAQ series modules overview… …………………………………………………………… 19 Software 31 DEWESoft……………………………………………………………………………………… 31 A/D Conversion A1 Internal Wiring B1 CE-Certificate of conformity C1 DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 15 Table of content 16 Main System Main System DEWE-5000 PC instrument series Portable data acquisition system Up to 256 channels with external expansion racks or PAD modules A/D converter specs see appendix A 16 internal slots for DEWE-DAQ/PAD modules System specifications Power supply: option 5000-PS-BAT: Operating temperature: Storage temperature: Humidity (operating): Vibration*: Shock*: Dimensions (W x D x H): Weight: *) tested with SSD disc DEWE-5000 400 W AC ATX power supply MPM-842P 400 W AC ATX power supply BEA-640 300 W DC ATX power supply DX-300HEW 300 W DC ATX power supply APT-DY300H 320 W DC ATX power supply XP-04 with DC-123 for details see next pages -5 °C to 50 °C (standard) -20 °C to +70 °C 10 % to 80 %, non condensing 5 % to 95 %, rel. humidity MIL-STD 810F 514.5 procedure I operating test procedure frequency range: 5 to 200 to 5 Hz; 5 x 12 min each direction displacement amplitude ±3.5 mm (5 to 8.45 Hz) acceleration amplitude 1 g (8.45 to 92 Hz) displacement amplitude 92 to 113 Hz: ±0.029 mm acceleration amplitude 1.5 g (113 to 200 Hz) MIL-STD 810F 516.5 procedure I non operating test procedure ½ sinus 11 ms 10 g, 3 shocks positive, 3 shocks negative approx. 453 x 200 x 351 mm (17.8 x 7.9 x 13.8 in.) typ. 17 kg (37.4 lbs), depending on configuration Dimensions* * Dimensions in mm (1 inch = 25.4 mm) 193 3 200 453 436 342 463 351 DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 17 Main System Connectors 9 10 12 Typical DEWE-5000 front view Combustion Analyzer option Connector overview: 3 2 4 5 6 11 7 1. Power supply connector with general power switch 2. PS/2 keyboard connector 3. PS/2 mouse connector 4. USB interface connectors 5. LPT interface connector 6. 2x RS-232 interface connectors 7. VGA connector 8. Ethernet LAN connector 9. Power-on button 10. Ground connectors 11. Digital I/O connector 12. Combustion Analyzer connectors (DEWE-5000-CA only) 8 Typical DEWE-5000 side view 1 Typical DEWE-5000 rear view Note: The location of the connectors might vary from system to system and depends on system configuration 18 Main System DAQ series modules overview Module Input type Ranges Bandwidth (BW), Isolation (ISO), TEDS Filters (LP = lowpass, Overvoltage HP = highpass) protection (OP) Universal measurement DAQP-STG V Strain gauge, bridge sensors ±0.1 to ±1000 mV/V (@ 5 VDCexc) Piezoresistive bridge ±0.5 to 10000 mV/mA (@ 1 mAexc) Voltage ±500 µV to ±10 V Resistance 25 mΩ to 100 kΩ Pt100, Pt200, Pt500, Pt1000, -200° C to 850° C BW: 300 kHz ISO: 350 VDC LP: 10 Hz to 300 kHz OP: ±50 VDC BW: 3 kHz ISO: 1 kVRMS Pt2000 MSI MSI MSI IEPE® via MSI-BR-ACC ±2.5 to ±10000 mV Thermocouple via MSI-BR-TH-x full range of TC type Charge via MSI-BR-CH-50 DAQP-MULTI V up to 50000 pC Voltage via MSI-BR-V-200 up to ±200 V Thermoresistors Pt100, Pt200, Pt500, Pt1000 and Pt2000, free programmable range Thermocouple Type K, J, T, R, S, N, E, B, L, C, U free programmable range Resistance 1 Ohm to 1 MOhm Piezoresistive bridge 13 ranges (±0.5 to 5000 mV/mA) Voltage 10 ranges from ±5 mV to ±5 V Current (with external shunt) depending on external shunt High voltage ±20 to ±1400 V LP: 3, 10, 30, 100, 300, 1000 Hz High voltage measurement DAQP-HV - BW: 300 kHz ISO: 1.8 kVRMS LP: 10 Hz to 300 kHz V DAQP-HV-S3 High voltage ±20 to ±1400 V - BW: 700 kHz ISO: 1.8 kVRMS LP: 10 Hz to 700 kHz V DAQP-DMM High voltage ±10 to ±1000 V - BW: 20/30 kHz ISO: 1.5 kVRMS LP: 10 Hz to 30 kHz V Voltage & current measurement DAQP-LV V MSI MSI MSI Voltage ±10 mV to ±50 V Current with external shunt 20 mA / 5 A IEPE® via MSI-V-ACC ±10 mV to 10 V Pt100, Pt200, Pt500, Pt1000, -200° C to 1000° C and Pt2000 and resistance via 0 to 6.5 kOhm BW: 300 kHz LP: 10 Hz to 300 kHz ISO: up to 1 kVRMS OP: 350 VDC MSI-V-RTD Charge via MSI-V-CH-50 DAQP-V V DAQN-AIN up to 50000 pC Voltage 10 mV to 50 V Current with external shunt 20 mA / 5 A - BW: 50 kHz LP: 10 Hz to 50 kHz ISO: up to 1 kVRMS OP: ±500 VDC Voltage ±10 V (1:1 input) - - V DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 OP: < ±500 V (jumper selectable) 19 Main System Module Input type Ranges Bandwidth (BW), Isolation (ISO), TEDS Filters (LP = lowpass, Overvoltage HP = highpass) protection (OP) Current measurement DAQP-LA-SC DAQP-LA-B Current 0.1 A to 30 A peak Note: 5 ARMS continuous max. 5 ARMS contin. current Current 2 mA to 600 mA - BW: 300 kHz ISO: 1.4 kVRMS LP: 10 Hz to 300 kHz - Note: typ. 20 mA application BW: 300 kHz ISO: 1.4 kVRMS LP: 10 Hz to 300 kHz Bridge / strain gauge and carrier frequency amplifier DAQP-CFB AC bridge, strain gauge Bridge: 0.1 to 1000 mV/V - Note: 5 kHz sine wave excitation DAQP-BRIDGE-A DAQP-B RIDGE-B BW: DC to 2.3 kHz OP: ±10 VDC LP: 10 Hz to 1 kHz Inductive sensors, LVDT Inductive: 5 to 1000 mV/V Strain gauge, bridge sensors ±1 to ±50 mV/V (@ 5 VDC) Potentiometric sensors 200 Ω to 10 kΩ Strain gauge, bridge sensors ±0.1 to ±100 mV/V (@ 5 VDC) - 1) BW: 20 kHz ISO: 350 VDC LP: 10 Hz to 20 kHz OP: ±10 VDC BW: 200 kHz OP: ±10 VDC LP: 10 Hz to 200 kHz Potentiometric sensors 200 Ω to 10 kΩ IEPE® sensors ±50 mV to ±5 V Charge / IEPE® measurement DAQP-ACC-A - BW: 0.5 Hz to 300 kHz LP: 1 to 300 kHz HP: 0.5 Hz and 5 Hz DAQP-CHARGE-A Charge sensors Charge: 5 to 50000 pC IEPE® sensors IEPE®: ±5 mV to 5 V - Charge sensors - HP: 0.1 Hz to 10 Hz Note: selectable integration and double integration DAQP-CHARGE-B BW: 0.1 Hz to 50 kHz LP: 100 Hz to 50 kHz ±100 to ±1 000 000 pC - BW: DC to 100 kHz ISO: 350 VDC LP: 10 Hz to 100 kHz HP: DC, 0.001 Hz to 0.5 Hz Note: selectable time constant for static sensors Temperature measurement DAQP-THERM Thermocouple Type K, J, T, R, S, N, E, B, L, C and U selectable Note: internal CJC and linearisation free programmable range Frequency 100 Hz to 200 kHz - BW: 3 kHz ISO: 1 kVRMS LP: 3, 10, 30, 100, 300, 1000 Hz Frequency measurement DAQP-FREQ-A - BW: according to range ISO: 350 VDC Output response: 1.5 ms 30 ms 500 ms Voltage output module DAQN-V-OUT Voltage output 1:1 output module with isolation Input voltage: ±10 V OUT 1) TEDS support for DAQP-BRIDGE-B revision 2 only 20 Output voltage: ±10 V - BW: 400 Hz ISO: 240 VDC Main System Modular smart interfaces to connect various sensors Modular Smart Interfaces for DAQP / MDAQ modules, DEWE-43 and DEWE-101 MSI-BR-ACC MDAQ-SUB-STG-D MDAQ-SUBBRIDGE-D MDAQ-SUB-V200-D DAQP-STG-D DAQP-LV-D DEWE-43 DEWE-101 - - Isotron (constant current powered) adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector Bandwidth and ranges are defined by connected amplifier Automatic adapter identification MSI-BR-V-200 - - 200 V input adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector Differential input configuration, BNC connector Bandwidth and ranges are defined by connected amplifier Automatic adapter identification MSI-BR-RTD - not needed - Pt100, Pt200, Pt500, Pt1000 and Pt2000 adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector 2, 3 and 4 wire connection methods, 5-pin Binder 710 series connector Automatic adapter identification MSI-BR-CH-x - - Charge input interface for DAQP-STG and MDAQ-SUB-BRIDGE / -STG with DB9 connector Range up to 50000 pC, AC coupled with 0.07 Hz, BNC signal connection Max. 100 kHz bandwidth (dependent on the max. bandwidth of the amplifier) Automatic adapter identification MSI-BR-TH-x - - isolated TC sensor any TC sensor isolated TC sensor Thermocouple type K / J / T adapter for DAQP-BRIDGE-x and MDAQ-SUB-BRIDGE / -STG modules with DB9 connector For use with isolated thermocouple sensors only ! (except in combination with DAQP-BRIDGE-A*) High accuracy cold junction reference measurement, 1 m thermo cable with Mini TC connector Automatic adapter identification MSI-V-ACC - - - - - Isotron (constant current powered) adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector Bandwidth and ranges are defined by connected amplifier Automatic adapter identification MSI-V-RTD - - - - - Pt100, Pt200, Pt500 and Pt1000 adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector 2, 3 and 4 wire connection methods, 5-pin Binder 710 series connector Automatic adapter identification MSI-V-CH-50 - - - - - Charge input interface for DAQP-LV, MDAQ-SUB-V-200 modules with DB9 connector Range up to 50000 pC, AC coupled with 0.07 Hz, BNC signal connection Max. 100 kHz bandwidth (dependent on the max. bandwidth of the amplifier) Automatic adapter identification DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 21 Main System Power supply connectors 400 W AC power supply 400 W AC power supply Input: Input range: Input frequency: Max. input current: Output: Output power: Output voltages: BEA-640 100 to 240 VAC (active PFC) 47 to 63 Hz 7 A (115 VAC), 3.5 A (230 VAC) 400 W continuous +3.3 V (max. 28 A) +5 V (max. 35 A) +5 Vsb (max. 2 A) +12 V (max. 30 A) -5 V (max. 0.5 A) -12 V (max. 0.8 A) AC power supply AC power switch 400 W AC power supply AC power supply 400 W AC ATX power supply MPM-842P Input: Input range: Input frequency: Max. input current: Output: Output power: Output voltages: AC power supply AC power switch 22 100 to 240 VAC (auto selecting) 47 to 63 Hz 8 A (115 VAC) 400 W continuous (450 W peak) +3.3 V (max. 22 A) +5 V (max. 21 A) +5 Vsb (max. 1.5 A) +12 V (max. 22 A) -12 V (max. 0.8 A) Main System 300 W DC power supply 300 W DC power supply Input: Input range: Input frequency: Max. input current: Output: Output power: Output voltages: APT-DX 300HEW 9 to 18 VDC (12 VDC nom.) DC 50 A 300 W +3.3 V (max. 20 A, min. 0.3 A) +5 V (max. 35 A, min. 0.3 A) +5 Vsb (max. 2 A) +12 V (max. 15 A) -5 V (max. 0.5 A) -12 V (max. 1 A) Ground connector DC power supply 300 W DC power supply 300 W DC power supply Input: Input range: Input frequency: Max. input current: Output: Output power: Output voltages: APT-DY300HEW 18 to 36 VDC (24 VDC nom.) DC 25 A 300 W +3.3 V (max. 28 A) +5 V (max. 30 A, min. 3 A, peak 35 A) +5 Vsb (max. 1.5 A) +12 V (max. 12 A, min. 1 A, peak 15 A) -5 V (max. 1 A) -12 V (max. 2 A) Ground connector DC power supply DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 23 Main System Internal battery power supply: option DEWE-5000-PS-BAT 320 W DC power supply with XP-04 battery management Input: Input range: Input frequency: Max. input current: 18 to 24 VDC (nom. 18 VDC) DC 12 A External AC power supply: 90 to 260 VAC (DEWE-POW-24-350 included as standard accessory) Output: Output power: Output voltages: 320 W with XP-04 battery management (with DCDC-123) +3.3 V (max. 10 A) +5 V (max. 10 A) +12 V (max. 12 A) Power supply pin assignment: + - Connector type 2-pin. male LEMO EGJ.2B.302 If option 5000-PS-BAT is installed, there are 3 slots for hotswappable smart batteries available in the system. Standard shipment includes 2 smart batteries, more can be ordered additionally (option BAT-95WH). Optional cables: C7502: LEMO 2B jack to LEMO 2B plug, 2 m. (used for connecting DEWE-2600 to DEWE-POW-24-350 or to DEWE-DCDC 24-350-ISO) C8502: LEMO 2B jack to banana plugs, 2 m. Note: If the system is powered by batteries, please take care that there are at least 2 batteries installed! In some special applications 3 batteries are necessary! (Hot swap of the batteries not possible) External AC/DC power supply (standard accessory included with option 5000-PS-BAT) AC/DC power supply Input: Input voltage: Input frequency: Input current (typ.): Inrush current (typ.): Leakage current: P.F.C. (typ.): Output: Output voltage: Min. load: Rated load (free / fan): Output tolerance: Ripple & Noise (max.): Efficiency (typ.): Output connector: DEWE-POW-24-350 90 to 264 VAC / 127 to 370 VDC universal input 47 to 63 Hz 2 A @ 230 VAC / 4 A @ 115 VAC 44 A @ 230 VAC / 22 A @ 115 VAC <2 mA @ 240 VAC 0.95 @ 230 VAC / 0.98 @ 115 VAC 24 V 0A 12.5 A / 14.6 A ±2 % 150 mV 88 % Banana jacks and LEMO EGG.2B.302 Protection: Overload: Over voltage: Over temperature: Short curcuit: 105 % to 130 % constant current limiting, auto recovery 26.7 to 32.4 V; Hiccup mode, auto recovery after fault has been removed > 80°C ±5°C detect on heat sink of power transistor Shutdown, auto recovery after temp. has fallen Yes Setup time: <2000ms @ 230VAC / 4000ms @ 115VAC Rise time: Holdup time: Withstand voltage: Isolation resistance: <100ms @ 230 VAC / 100ms @ 115 VAC 16ms @ 230 VAC / 16ms @ 115 VAC I/P-O/P:3 KVAC, I/P-FG:1.5 KVAC, O/P-FG:0.5 KVAC / 1 minute I/P-O/P, I/P-FG, O/P-FG: 500 VDC / 100 MOhm Switching frequency: 100 kHz Temperature: Operating: Derating: Storage: -10 to 65°C 45 to 60°C: 2 %/°C (3.5 & 5 V: 40 to 65°C: 2 %/°C) -40 to 85°C Humidity: Operating: Storage: 20 to 90 % RH 10 to 95 % RH (non condensing) M.T.B.F.: > 106 K hours ( according to MIL-HDBK-217F at 25°C environment) Safety: Approved: UL 60950-1 / TÜV EN60950-1 EMC: EMI EMS EN55022 Class B / EN61000-3-2,3 EN61000-4-2,3,4,5,6,8,11 / ENV50204 Dimensions (W x D x H): 248 x 106 x 62 mm (9.8 x 4.2 x 2.4 in.) Weight: 1.7 kg (3.7 lbs) 24 Main System DEWE-5000 with option PS-BAT and external AC/DC power supply External AC Power supply 24 + Cable C7502 Smart battery packs C VD - Lemo EGG.2B.302 DEWE-POW-24-350 90 to 260 VAC IN Smart battery packs are equipped with an integrated circuit which stores information (such as manufacturer, serial number, production date etc.) and monitors the current battery status in terms of discharge rate, predicted remaining capacity, temperature, voltage etc. The battery packs, supplied with every battery powered DEWETRON system, are even capable of displaying their charge state without a separate device. With the push of a button, a LED display on the battery pack shows the current charge state in 25% steps. An intelligent battery controller, integrated in our DEWETRON systems, takes care of the charging and discharging process in order to ensure maximum battery performance and life time. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 25 Main System External battery charger (optional) External battery charger CH5000A/E/U Power supply: Input voltage: Input current: Mains Cord: Dimensions (WxDxH): Weight: Mating connector: 90 to 260 VAC, 24V 2.5 A CH5000E - 220 V European 2-pin connector with ground recess 180 mm x 92 mm x 58 mm ca. 250 g 5-blade standard battery connector From time to time, due to the aging process of the batteries, it is necessary to recalibrate the battery in order to retain the accuracy and reliability of the fuel gauge. This can be archieved with an external battery charger (BAT-CHARGER) which is optionally available. Another advantage of the BAT-CHARGER is that additional batteries can be recharged without being in the measurement unit. This allows the measurement unit to run non-stop without being connected to the power net, thanks to the hot-swap capability of the battery packs. 26 Main System PS/2 mouse connector The mouse / trackball connector is used to connect the trackball embedded in the keyboard or an external PS/2 mouse. The connector meets standard PS/2 pin assignment. PS/2 keyboard connector The keyboard connector is used to connect PS/2 keyboard to DEWE-5000 system. The connector meets standard PS/2 pin assignment. USB interface connectors (Universal Serial Bus) The USB interface connectors meets standard USB pin assignment. LPT printer interface connector The printer interface connector (female) is located on the right side of the DEWE-5000. It is configured as standard LPT interface. 25-pin SUB-D connector (female) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Schematic Pin assignment 1: Strobe 2: Data 1 3: Data 2 4: Data 3 5: Data 4 6: Data 5 7: Data 6 8: Data 7 9: Data 8 10: ACK 11: Busy 12: PE 13: Select 14: 15: 16: 17: 18: 19: 20: 21: 22: 23: 24: 25: Auto FD Error Init Select In GND GND GND GND GND GND GND GND RS-232 interface connector (COM1) The RS-232 interface connector (male) is located on the right side of the DEWE-5000. It is configured as standard RS-232 interface COM 1 and can be used for mouse or other peripheral units. 1 2 3 4 5 9-pin SUB-D connector (male) 6 7 8 9 Schematic Pin assignment 1: DCD (Data Carrier Detector) 2: RD (Received Data) 3: TD (Transmitted Data) 4: DTR (Data Terminal Ready) 5: GND (Ground) 6: DSR (Data Set Ready) 7: RTS (Request To Send) 8: CTS (Clear To Send) 9: RI (Ring Indicator) DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 27 Main System VGA connector The VGA connector offers the possibility to connect an external CRT or other standard VGA displays to the system. 5 4 3 2 1 10 9 8 7 6 15-pin mini-SUB-D connector (male) 15 14 13 12 11 Schematic Pin assignment 1: Red video 2: Green video / Sync on green 3: Blue video 4: 5: 6: Red video ground 7: Green video ground 8: Blue video ground 9: 10: Ground 11: Ground 12: Data line 13: H-Sync / HV-Sync 14: V-Sync 15: Clock line Some systems have a DVI connector instead or additionally to the VGA. 15-pin mini-SUB-D connector (male) Schematic Pin assignment 1: 2: 3: 4: 5: 6: 7: 8: TDMS-data 2TDMS-data 2+ Shield TDMS-data 2,4 TDMS-data 4TDMS-data 4+ DDC clock DDC data Analog: V-Sync 9: TDMS-data 110: TDMS-data 1+ 11: Shield TDMS-Daten 1,3 12: TDMS-data 313: TDMS-data 3+ 14: +5 volt 15: Ground for +5 volt 16: Hotplug-Detect 17: TDMS-data 018: TDMS-data 0+ 19: Shield TDMS-data 0,5 20: TDMS-data 521: TDMS-data 5+ 22: Shield TDMS-Takt 23: TDMS-clock+ 24: TDMS-clock - C1: Analog: red C2: Analog: green C3: Analog: blue C4: Analog: H-Sync C5: Analog: ground Ethernet connector The DEWE-5000 system supports 10/100 BaseT Ethernet with standard RJ45 connector. Power-on button The power-on button has to be used to switch on the system. It only works when the main power switch is on. 28 Main System Power supply backplane / cooling fan The AMP connector is the internal power supply connection to the internal rack and the cooling fan, mounted on the backplane of the DEWE-5000 system. 6-pin AMP connector 3 2 1 6 5 4 Schematic Pin assignment 1: +12 V 2: GND 3: not connected 4: -12 V 5: GND (EPAD supply) 6: +12 V (EPAD supply) Digital I/O connector This connector supports digital input and output lines of the built-in A/D board. If this board does not support digital I/O’s, the connector is not available. The pin assignment is depending on the used A/D board - details are available in appendix B. Ground connectors For some kind of measurements, it’s necessary to give the system an additional ground connection. Combustion Analyzer I/O connectors (DEWE-5000-CA) The Combustion Analyzer requires several special input signals to work. Please refer to appendix B (wirings) for details. Signal output 1 (wiring according to appendix B) Signal output 2 (wiring according to appendix B) Crank Angle Sensor CA Connector ‘Zero position’ signal (upper death point signal), TTL level input CDM - angle position signal from high resolution encoders, TTL level input DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 29 Main System Optional connector for current power probe supply This connector supports ±9 V current power probe supply for connecting current clamps. 3-pin Binder series connector 1 3 2 Pin assignment 1: +9 V 2: GND 3: -9 V BINDER-712 series 6-pin male/female Lemo connector (with digital inputs of ORION board) 3 2 1 4 5 6 Lemo EGG.1B.306 30 Pin assignment 1: +15 V 2: -15 V 3: +9 V 4: DGND 5: DI(x) 6: DGND x .. digital inputs 0..7 of the ORION board Software DEWESoft DEWESoft DEWESoft turns your hardware into a powerful data acquisition system. Our award-winning data acquisition package is second to none when it comes to both pure recording power and ease of use. Normally this is a difficult balancing act: providing lots of capability and performance, without making the user interface hard to learn. But we‘ve done it! DEWESoft is the solution to acquire signals synchronous from different sources, display and store them together and offer the data for post analysis. Measure Scope Recorder FFT Video Export Print One of the most powerful and yet easy to use aspect of DEWESoft is the creation of displays. Of course, a few standard displays are builtin for you, like screens for these instruments: Recorder (vertical and horizontal recorder screens are included) Oscilloscope (free run, triggered, with 2D and 3D waterfall displays, and more) FFT (with selectable axes, line length, window, type, averaging, overlapping, weighting, and more) Video – Scalable video window with an assignable recorder graph below GPS – Track with background map, plus speed, distance, heading, etc. Analyze Mode REPLAY, EXPORT, SHARE DATA! Here you can replay any captured data file, zoom in with the recorder graph cursors, make measurements, print in full color to any Windows printer, and export the data to a wide variety of formats compatible with today‘s popular analysis software packages, like Flexpro, Matlab, Excel, and many more. You can even export a AVI video file from your recorded data to create “moving documentation.“ NO LICENSE is needed to use DEWESoft in the ANALYZE mode, so you can install the software on all your computers, or even distrbute it to your customers, and they can install it. In this way, all of your colleagues and customers can replay your data files and do all of the functions that you can – just give them the data file to open. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 31 DEWESoft Notes 32 A/D Conversion A/D & D/A Conversion A/D Conversion Please find information about the A/D conversion in the attached DEWE-ORION series manual. The latest version of the manual can be downloaded from: http://download.dewetron.com/dl/components/adboards Informations regarding different manufacturer's see the corresponding D/A card manual. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 A1 A/D & D/A Conversion Notes A2 Internal Wiring Internal Wiring 16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-DE-x Rear view W7 5 = 5 V output; 330 kHz filter 10 = 10 V output; 330 kHz filter GND +15 V ORION -15 V ORION W1 CH 0 W10 Front view CH 1 W11 16 channels single ended analog output (output resistance 15 Ohm) Please find the pin-assignment on the next page! W8 CH 2 CH 3 5 V ORION Ext. CLK Ext. TRIG DGND ORION Ext. CLK 2 OUT Ext. CLK 1 OUT (CAMERA TRIGGER) W9 CH 4 CH 5 DGND ORION W5 CH 6 CH 7 Terminate RS-485 Connect GND to GNDP W3 Connect +12 V to +V (pin 6) W4 Terminate RS-485 W5 Connect chassis to GND W6 Connect chassis to GND W7 Connect chassis to GND W8 Activate ORION RS-485 (A) W9 Activate ORION RS-485 (B) W1 16x GND 16 x analog OUT (resistance 50 Ohm) GND W2 CH 8 CH 9 CH 10 CH 11 Activate analog output 0 on CH 14 W11 Activate analog output 1 on CH 15 W10 CH 12 Note: If you connect signals to these contacts you have to open the solder jumpers W10 and W11 first! CH 13 CH 14 Connection to CH14 (pin 7) Indicator +9 V -9 V CH 15 Connection to CH15 (pin 7) 1 2 3 4 5 W4 W3 +V +12 V GNDP -12 V -V GNDC GNDC TX RX 1 2 3 4 5 6 RS-232 9-pin SUB-D pin assignment: A (RS-485) GNDC B (RS-485) GNDP +V +12 V -12 V -V RS-485 RS-485 W2 6 7 8 9 GND POWER W6 POWER DM DP GNDC RX TX GNDC B B A A USB RES GND 7 8 9 Module input (±5 V) RS-485 (A) RS-485 (B) GND +9 V power supply +12 V power (default) / +V sensor supply Module output (from A/D board) -V sensor supply -9 V power supply The 16 slot DEWE-MOTHERBOARD receives the ±12 VDC power supply via a DC/DC converter from the internal power supply. DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 B1 Internal Wiring Analog output connector pin-assignment Connector for DEWE-ORION-1616 cards +15 V AGND AGND AGND AGND AGND AGND AGND AGND AGND AISENSE2 AGND AGND AGND AGND AGND AGND AGND AISENSE1 AGND DI8/DO0 DI9/DO1 DI10/DO2 DI11/DO3 DI12/DO4 DI13/DO5 DI14/DO6 DI15/DO7 +5 V DGND DGND +5 V DGND DGND 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Connector for DEWE-ORION-1624 cards -15 V AGND AGND CH15+ CH14+ CH13+ CH12+ CH11+ CH10+ CH9+ CH8+ CH7+ CH6+ CH5+ CH4+ CH3+ CH2+ CH1+ CH0+ AGND DI0/Source(0) DI1/Gate(0) DI2/AUX_U_D(0) DI3/Source(1) DI4/Gate(1) DI5/AUX_U_D(1) RS-485A RS-485B DI 6 DI 7 EXT_CLK EXT_Trigger EXT_CLK1 EXT_CLK2 +15V AGND AGND CH. 15CH. 14CH. 13CH. 12CH. 11CH. 10CH. 9CH. 8CH. 7CH. 6CH. 5CH. 4CH. 3CH. 2CH. 1CH. 0AGND NC. NC. NC. NC. NC. NC. NC. NC. +5 V DGND DGND +5 V DGND DGND 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 -15 V AGND AGND CH. 15+ CH. 14+ CH. 13+ CH. 12+ CH. 11+ CH. 10+ CH. 9+ CH. 8+ CH. 7+ CH. 6+ CH. 5+ CH. 4+ CH. 3+ CH. 2+ CH. 1+ CH. 0+ AGND NC. NC. NC. NC. NC. NC. RES.* RES.* RES.* RES.* RES.* EXT-TRIGGER SAMPLE CLOCK NC. * DONT CONNECT 68-pin high density connector 68-pin high density connector 16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-NI-x-U 5 = 5 V output; 330 kHz filter 10 = 10 V output; 330 kHz filter Connector for National InstrumentsTM A/D cards DGND DGND PFI 8/P2.0 PFI 7/P1.7 PFI 15/P2.7 PFI 13/P2.5 PFI 4/P1.4 PFI 3/P1.3 PFI 2/P1.2 DGND PFI 10/P2.2 PFI 11/P2.3 P0.3 P0.7 P0.2 DGND P0.5 P0.0 DGND AO GND AO GND AI GND AI 7 AI 14 AI GND AI 5 AI 12 AI Sense AI 11 AI GND AI 2 AI 9 AI GND AI 0 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 PFI 14/P2.6 PFI 112/P2.4 PFI 9/P2.1 DGND PFI 6/P1.6 PFI 5/P1.5 DGND +5 V DGND PFI 1/P1.1 PFI 0/P1.0 DGND DGND +5 V DGND P0.6 P0.1 DGND P0.4 APFI 0 AO 1 AO 0 AI 15 AI GND AI 6 AI 13 AI GND AI 4 AI GND AI 3 AI 10 AI GND AI 1 AI 8 68-pin high density connector B2 USB interface on-board Rear view W7 W1 DGND 16 channels single ended analog output (output resistance 15 Ohm) Please find the pin-assignment on the next page! Analog OUT Ch. 1 Analog OUT Ch. 0 Terminate RS-485 Connect GND to GNDP W3 Connect +12 V to +V (pin 6) W4 Terminate RS-485 W5 Connect chassis to GND W6 Connect chassis to GND W7 Connect chassis to GND W1 DGND GND W2 CE-Certificate of conformity CE-Certificate of conformity Manufacturer: DEWETRON Elektronische Messgeraete Ges.m.b.H. Address: Parkring 4 A-8074 Graz-Grambach Austria Tel.: +43 316 3070 0 Fax: +43 316 3070 90 e-mail: [email protected] http://www.dewetron.com Name of product: DEWE-5000 Kind of product: Data acquisition instrument The product meets the regulations of the following EC-directives: 73/23/EEC "Directive on the approximation of the laws of the Member States relating to electrical equipment designed for use within certain voltage limits amended by the directive 93/68/EEC" 89/336/EEC "Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility amended by the directives 91/263/EEC, 92/31/ EEC, 93/68/EEC and 93/97/EEC The accordance is proved by the observance of the following standards: L V E M C Safety IEC/EN 61010-1:1992/93 IEC/EN 61010-2-031 IEC 61010-1:1992/300 V CATIII Pol. D. 2 IEC 1010-2-031 Emissions EN 61000-6-4 EN 55011 Class B Immunity EN 61000-6-2 Group standard Graz, October 14, 2008 Place / Date of the CE-marking Dipl.-Ing. Roland Jeutter / Managing director DE-M040302E • DEWE-5000 • Technical Reference Manual • Printing version 2.2.3 • January 19, 2012 C1 Notes C2 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Up to 256 channels
- Modular design
- Multiple sensor types support
- Portable system
- DEWESoft software
- Robust design
- Various power supply options
- Wide temperature range
- Internal battery option
Frequently asked questions
The DEWE-5000 is a data acquisition system used for measuring various physical and electrical parameters, including voltage, current, temperature, strain, and more, depending on the configuration.
The DEWE-5000 can support up to 256 channels, depending on the configuration and modules used.
The DEWE-5000 includes connectors for various input types, including safety banana plugs, BNC connectors, D-SUB connectors, thermocouple connectors, BINDER® connectors, SMB connectors, µdot connectors, LEMO® connectors and RJ-45 connectors. Specific connectors are depending on the chosen configuration of the device.