Technical Overview
Tackle Complex
Networks in Less Time
FieldFox
With the proliferation of wireless
communications, operating
frequencies have soared from
sub-GHz levels up to 5.8 GHz.
As a result, service providers
are required to build more base
stations to cover the same size
coverage area. This means you
and your technicians need to
deploy and maintain more cell
sites than you previously did in
the same amount of time. To do
this efficiently, a multi-functional
and reliable tool is required.
The Agilent FieldFox RF Analyzer
is the tool to tackle today’s
increasingly complex networks
in less time.
22
FieldFox
World’s Most Integrated
Handheld RF Analyzer
Key measurements
• Cable and antenna test (distance to
fault, return loss, etc.)
• Cable loss measurement
• Insertion loss and transmission
measurement
• Spectrum analyzer
• Power meter with USB power sensor
• Vector network analysis with Smith
chart display
Key differentiators
• Integrated QuickCal calibrates without
a calibration kit
• Immediate calibration with CalReady
• 50 percent faster than traditional
handheld instruments
• Superior dynamic range (96 dB) and
sensitivity (-148 dBm) in the spectrum
analysis mode
• Easy-to-use, task-driven user interface
33
FieldFox
Task-driven Features
7.4” W
188 mm
Connector covers
help keep dust out
Anti-glare 6.5 inch
LCD display with
LED backlight
Convenient side
strap makes it
easy to hold and
carry
11.5” H
292 mm
Task-driven keys
are grouped to
easily and
naturally perform
standard field
measurements
Portrait design and
large buttons for
easy operation —
even with gloves on
Dedicated marker keys for
quick marker function access
Backlit keypad
44
FieldFox
2.8” D
72 mm
RF Out
External reference
Connector bay protects
RF connectors
Easily accessible
battery compartment
RF In
Spacious connector design makes
connections fast and simple
LAN port for fast
data transfer
SD flash card slot for
additional data storage
Quick-connect
shoulder strap clips
Built-in
headphone jack
USB ports for convenient
data transfer
Gasketed doors protect
ports from moisture
55
FieldFox
Key Measurements
Cable and antenna analyzer
Fifty to sixty percent of cell site problems
are caused by faulty cables, connectors, and
antennas. Degraded feed lines cause poor
coverage, unnecessary handovers, paging
failures, and access failures on uplink. To
avoid service quality problems, it is critical to
keep cell sites’ cable and antenna systems
in good condition.
Use FieldFox to make return loss, VSWR,
insertion loss/transmission, one-port cable
loss, and distance to fault (DTF) measurements.
You can test antennas, cables, filters, and
amplifiers with a single instrument.
Insertion loss display
Return loss and DTF dual display
Return loss and DTF
measurements
FieldFox can make both return loss and
distance to fault measurements at the same
time. This helps you correlate overall system
degradation with specific faults in the cable
and antenna system.
66
FieldFox
Measurements in the field
without the need to manually
calibrate
Each instrument is CalReady at the RF Out
port, immediately following power-on or
preset. This means it’s already calibrated and
ready to make accurate measurements such
as one-port cable loss, VSWR, return loss, and
DTF measurements at the test port.
Calibration Wizard
Industry’s first and only
QuickCal
The industry’s first and only built-in calibration system allows you to calibrate the cable/
antenna tester without carrying a calibration
kit into the field. As with any test instrument,
when you add an additional device to the test
port, such as a jumper cable or attenuator, you
need to calibrate using a calibration kit (cal kit).
QuickCal eliminates the hassle of carrying
and using a cal kit, plus provides worry-free
accuracy and excellent repeatability every
time.
77
FieldFox
Broadband calibration
FieldFox allows you to make broadband
calibrations, which means the instrument
is calibrated over the maximum frequency
span. After a broadband calibration, you can
change the frequency range or number of
points without recalibrating the instrument.
Built-in spectrum analyzer
Interference is a major source of cell site
problems. Interference can be internal or
external, and uplink or downlink. Downlink
interference reduces coverage, while uplink
interference causes access failure. Interference has a direct impact on the quality
of service of wireless communication
services.
FieldFox has an optional built-in spectrum
analyzer that covers frequency ranges
from 100 kHz to 6 GHz. It provides a fast
spectrum scan to detect interference and
RF burst capture to measure intermittent
signals. It displays four traces at the same
time, and you can choose different detector
modes.
Spectrum analyzer display
88
FieldFox
Power meter
FieldFox can connect with the Agilent U2000
Series USB power sensor to make RF/microwave
power measurements up to 24 GHz.
FieldFox provides true average power measurements with a wide dynamic range from -60 dBm
to +44 dBm.
The sensor has an internal zeroing function,
and external calibration is not needed.
Transmission measurement
FieldFox provides a 2-port transmission
measurement that measures insertion loss,
amplifier gain, filter passband, and loss. It also
makes a S21 scalar measurement if Option 303
is enabled. This option covers the 2 MHz to
6 GHz frequency range.
Network analysis
FieldFox has an optional network analyzer mode
that provides standard vector network analyzer
measurements such as S11, S11 phase, S21
magnitude and a Smith chart display.
Transmission measurement
99
FieldFox
Feature and Benefit Summary
Comprehensive measurement capabilities
Cable and antenna
test
• Return loss, VSWR
• Distance to fault
Return loss/VSWR measurements allow you to evaluate the
impedance matching performance of the feed line across the
frequency range of interest.
Distance to fault measurements help you identify the faults
along a feed line. Use these measurements to precisely pinpoint
the location of damaged or degraded antennas, connectors,
amplifiers, filters, and duplexers, etc.
FieldFox provides up to 1001 data-point resolution to help accurately locate faults and extend measurement distance.
Perform and view return loss and distance to
fault measurements at the same time
Transmission test
• Cable loss
• Insertion loss
• Amplifier gain
Transmission test is used to accurately measure cable loss,
insertion loss (filters), and amplifier gain (tower mounted amplifier). FieldFox offers two-port transmission magnitude measurements with up to 72 dB dynamic range.
One-port cable loss
For already-installed cables, FieldFox accurately measures cable
loss via the RF Out port. The instrument measures actual cable
loss, without the need for additional computation.
CalReady at test port
Each instrument is calibrated at the RF Out port. When you
power up the instrument, it is ready to make accurate measurements such as one-port cable loss, VSWR, return loss, and DTF
at the test port.
QuickCal
The industry’s-first and only built-in calibration system allows
you to calibrate the cable and antenna tester without carrying
a calibration kit with you all the time. It provides worry-free
accuracy and excellent repeatability. QuickCal also corrects
drift errors caused by temperature changes during instrument
operation.
Mechanical
calibration
Open-short-load (OSL) is standard in FieldFox. There are four
calibration kits defined in the instrument.
Spectrum analysis
The built-in spectrum analyzer allows you to scan up to 6 GHz
and detect internal and external interference. FieldFox can
detect signals as low as -148 dBm up to 6 GHz, with phase noise
-88 dBc at 10 kHz, and a third order intercept (TOI) better than
+18 dBm.
Power meter
Makes accurate true average power measurements without
bringing a power meter along. The state-of-the-art Agilent USB
power sensors provide measurements up to 24 GHz.
Smith chart
Smith charts can be used to display impedance matching characteristics in cable and antenna systems.
Make accurate true average power measurements without bringing along a power meter
10
FieldFox
Field-proof usability
Transflective display
and backlit keys
The display is designed for easy viewing in indoor and outdoor
settings and in direct sunlight and darkness. Access different
display modes via softkeys.
Task-driven key
design
Front-panel keys are grouped to easily and naturally perform
standard field measurements.
Speaker and
headphone jack
Used for future demodulated audio signal capability.
One-button
measurement
Provides task-driven user interface to simplify the measurements.
Rugged design
Transflective display makes it easy to read
measurements in direct sunlight
Water-resistant chas- The case is made from polycarbonates that withstand wide
sis, keypad and case temperature ranges and salty, humid environments.
design
RF connector
protection
A specially designed connector bay protects the RF connectors
from damage during drops or other external impacts.
Dust-free design
With no vents or fans in the case, FieldFox resists dust for better
equipment reliability.
Meets tough environmental standard
Meets MIL-PRF-28800F Class 2 specification.
Gasketed doors
Protects instrument interface from moisture.
Modern connectivity
Water resistant chassis withstands wide
temperature ranges and humid environments
USB 2.0 ports
Two USB 2.0 ports can be used to transfer files.
LAN port
Used to transfer data in and out of the instrument.
SD flash card slot
Use as a data storage device.
FieldFox Data Link
software
Transfer data remotely from the instrument to a PC for backoffice applications such as baseline analysis and report
generation.
11
11
FieldFox
Specifications
Typical (typ.):
Expected performance of an average unit over a 20 °C to
30 °C temperature range, unless otherwise indicated; does
not include guardbands. It is not covered by the product
warranty. The FieldFox must be within its calibration cycle.
Specification (spec.):
Warranted performance. Specifications include guardbands to account for the expected statistical performance
distribution, measurement uncertainties, and changes in
performance due to environmental conditions. The following conditions must be met:
Nominal (nom.):
A general, descriptive term or design parameter. It is not
tested, and not covered by the product warranty.
• FieldFox has been turned on at least 90 minutes
• FieldFox is within its calibration cycle
• Storage or operation at 25 °C ±5 °C range
(unless otherwise stated)
Cable and antenna analyzer (Option 104 or 106)
Frequency
Frequency range
Option 104
2 MHz to 4 GHz
Option 106
2 MHz to 6 GHz
Frequency reference
Accuracy
Aging rate
Temperature stability
±2 ppm
±1 ppm/yr
±1 ppm over -10 to 55 ºC
Frequency resolution
2 MHz to 1.6 GHz
> 1.6 GHz to 3.2 GHz
> 3.2 GHz to 6 GHz
2.5 kHz
5 kHz
10 kHz
Measurement speed
Return loss
Distance to fault
1.5 ms/point (nominal)
1.75 GHz to 3.85 GHz, 1001 points, Cal ON
2.4 ms/point (nominal)
0 to 500 ft, 601 points, Cal ON
Data points
101, 201, 401, 601, 801, 1001
Directivity
Corrected
QuickCal (Option 111)
> 42 dB
> 42 dB (typical)
Source match
Corrected
QuickCal (Option 111)
> 36 dB
≥ 35 dB (typical)
Reflection tracking
Corrected
QuickCal (Option 111)
± 0.06 dB
± 0.15 dB (typical)
12
12
FieldFox
Dynamic range
Reflection (RF Out port)
2 MHz to 4 GHz
60 dB (typical)
> 4 GHz to 6 GHz
55 dB (typical)
Transmission measurement (Option 110)
2 MHz to 2 GHz
72 dB (typical)
2 GHz to 3 GHz
67 dB (typical)
> 3 GHz to 5 GHz
58 dB (typical)
> 5 GHz to 6 GHz
49 dB (typical)
Output power range
High power
2 MHz to 4 GHz
< +8 dBm, +6 dBm (nominal)
> 4 GHz to 6 GHz
< +7 dBm, +2 dBm (nominal)
Low power
2 MHz to 4 GHz
< -23 dBm, -25 dBm (nominal)
> 4 GHz to 6 GHz
< -24 dBm, -25 dBm (nominal)
Immunity to interference
+16 dBm (nominal)
Maximum input level (RF Out port)
+23 dBm
Maximum input DC voltage (RF Out port)
50 VDC
13
13
FieldFox
Cable and antenna measurements
Return loss
Display range
0 to 100 dB
Resolution
0.01 dB
Display range
0 to 100
VSWR
Resolution
0.01
Distance to fault (DTF)
• Range = (number of points - 1)/(span*2) x Vf (velocity factor in cable) x c (light speed)
• Resolution = range/(number of points - 1)
• Number of points: 101, 201, 401, 601, 801, 1001
• Distance to fault display: Return loss, VSWR
Cable loss (1-port)
Terminated cable under test with short
Insertion loss (2-ports)
Requires Option 110
Transmission measurement (Option 110)
Frequency range
Option 104
2 MHz to 4 GHz
Option 106
2 MHz to 6 GHz
Dynamic range
2 MHz to 2 GHz
72 dB (typical)
2 GHz to 3 GHz
67 dB (typical)
> 3 GHz to 5 GHz
58 dB (typical)
> 5 GHz to 6 GHz
49 dB (typical)
Frequency resolution
5 kHz
Readout resolution
0.001
14
14
FieldFox
Network analysis (Option 303)
S11
Vector measurement, S11 magnitude and S11 phase. Specification is listed under Cable and
antenna analyzer section (S11/Return loss, S21/Insertion loss).
S21
Scalar measurement, S21 magnitude. Specification is listed under transmission measurement.
S21 requires Option 110 transmission measurement.
A
Reflected power
R
Source power
Display
Log, linear, phase, VSWR, Smith chart
Calibration types
Mechanical cal
QuickCal
Normalization
Automatic cal update with frequency change or number of points change
Spectrum analyzer (Option 230 or 231)
Frequency
Frequency range
Option 104
100 kHz to 4 GHz, usable to 5 kHz
Option 106
100 kHz to 6 GHz, usable to 5 kHz, tunable to 6.1 GHz
Frequency reference
Accuracy
Frequency aging
Frequency reference
temperature stability
±2 ppm
± 1 ppm/yr
± 1 ppm over -10 to 55 °C
Frequency readout accuracy
± (readout frequency x frequency reference accuracy + RBW centering + 0.5 x horizontal
resolution)
Frequency span
Range
0 Hz (zero span), 1 Hz to maximum frequency
Span accuracy
±(2 x RBW centering + horizontal resolution)
Span resolution
1 Hz
15
15
FieldFox
Resolution bandwidth (RBW)
Range (-3 dB bandwidth)
Zero span
Non-zero span
300 Hz to 1 MHz in 1-3-10 sequence; 2 MHz
10 Hz to 300 kHz in 1/1.5/2/3/5/7.5/10 sequence; 1 MHz, 2 MHz
Accuracy
1 kHz to 1 MHz: ± 5% (nominal)
10 Hz to 100 KHz non-zero span: ± 1% (nominal)
2 MHz: ± 10% (nominal)
300 Hz zero span: ± 10% (nominal)
Selectivity (-60 dB/ -3 dB)
4:1 (nominal)
Video bandwidth (VBW)
Range
1 Hz to 2 MHz in 1/1.5/2/3/5/7.5/10 sequence
Stability
Noise sidebands, CF = 1 GHz
10 kHz offset: -88 dBc/Hz ( typical)
30 kHz offset: -89 dBc/Hz, (typical)
100 kHz offset: -95 dBc/Hz, (typical)
1 MHz offset: -115 dBc/Hz, (typical)
Sweep acquisition, span > 0 Hz
Range
Resolution
Readout
1 to 5000, number of data acquisitions per trace point; value is normalized to the minimum
required to achieve amplitude accuracy with CW signals
1
Measured value representing time required to tune receiver, acquire data, and process trace
Trace updates
Span = 20 MHz, RBW = 3 kHz: 1.5 updates/second
Span = 100 MHz, RBW auto coupled: 7 updates/second
Span = 6 GHz, RBW auto coupled: 1 update/second
Trace points
101, 201, 401, 601, 801, 1001 points, default is 401
16
FieldFox
Amplitude
Measurement range
Displayed average noise level (DANL) to +20 dBm
Input attenuator range
0 to 31 dB, 1 dB steps
Maximum DC voltage at RF In port
50 V
Maximum input power at RF In port
+27 dBm (0.5 W)
Displayed average noise level (DANL)
10 Hz RBW, 10 Hz VBW, 50 ohm termination on input, 0 dB attenuation, average detector
Preamplifier OFF
20 to 30 °C
10 MHz to 2.4 GHz
-130 dBm (typical)
> 2.4 GHz to 5.0 GHz
-125 dBm (typical)
> 5.0 GHz to 6.0 GHz
-119 dBm (typical)
Preamplifier ON (Option 235)
20 to 30 °C
10 MHz to 2.4 GHz
-148 dBm (typical)
> 2.4 GHz to 5.0 GHz
-145 dBm (typical)
> 5.0 GHz to 6.0 GHz
-138 dBm (typical)
-10 to 55 °C
10 MHz to 2.4 GHz
< -141 dBm
> 2.4 GHz to 5 GHz
< -138 dBm
> 5 GHz to 6 GHz
< -130 dBm
Total absolute amplitude accuracy
Peak detector, 10 dB attenuation, preamplifier off, RBW < 2 MHz, input signal 0 dBm to -50 dBm, all settings auto-coupled
20 to 30 ºC
2 MHz to 10 MHz
±1.8 dB
±0.60 dB (typical)
> 10 MHz to 3.0 GHz
±1.5 dB
±0.50 dB (typical)
> 3.0 GHz to 5.0 GHz
±1.9 dB
±0.60 dB (typical)
> 5.0 GHz to 6.0 GHz
±2.1 dB
±0.60 dB (typical)
Second harmonic distortion (SHI)
-30 dBm signal at input mixer
2 MHz to 1.35 GHz
< -70 dBc, +40 dBm SHI (nominal)
1.35 GHz to 3.0 GHz
< -80 dBc, +50 dBm SHI (nominal)
17
FieldFox
Third order intermodulation distortion (TOI)
Two -30 dBm tones at input mixer
< -96 dBc, +18 dBm TOI (nominal)
Residual responses
Input terminated, 0 dB attenuation, preamplifier off, RBW ≤ 1 kHz, VBW auto-coupled
20 MHz to 3 GHz
-90 dBm (nominal)
> 3 GHz to 6 GHz
-85 dBm (nominal)
Spurious responses
Input mixer level -30 dBm
RFsig = RFtune + 417 MHz
-70 dBc (nominal)
RFsig = RFtune + 1.716 GHz
-80 dBc (nominal)
Input mixer level -10 dBm, first IF image response
RFsig = RFtune – 2 x 0.8346 GHz,
for RFtune 5.7 to 6.0 GHz
Sidebands
-50 dBc (nominal)
-80 dBc (nominal)
-60 dBc (nominal) when battery charging, 260 kHz offset
Preamplifier (Option 235 requires Option 230 or 231)
Option 230
100 kHz to 4 GHz
Option 231
100 kHz to 6 GHz
Gain
22 dB (nominal)
Reference level
Range
Resolution
Accuracy
-170 dBm to +30 dBm
0.1 dB
0 dB (no error)
Traces
4 traces, data/max/average/min
Detectors
Normal, positive peak, negative peak, sample, average
Markers
Marker types
Number of markers or
delta markers
Marker functions
Normal, noise marker
6
Peak, next peak, peak left, peak right, marker to center, minimum search
RF In VSWR
1.5:1 (50 ohm)
18
FieldFox
Power meter measurement (Option 302)
Frequency range
9 kHz to 24 GHz (sensor dependent)
USB power sensor
9 kHz to 24 GHz, see Agilent U2000 Series USB power sensor specifications for details
General specifications
Connector type
Type-N (female)
Input impedance
50 ohm
External reference
Input type
Reference frequency
Required level
BNC female
10 MHz
-5 dBm to 10 dBm
Display
6.5” transflective, color VGA LED backlit 640 x 480 with anti-glare coating
Speaker
Built-in speaker
Headphone jack
Built-in headphone jack
Connectivity
2 x USB 2.0; 1 x mini USB; 1 x LAN
Internal storage
Minimum 16 MB, up to 1000 traces
External storage
1 x mini SD slot and 2 x USB 2.0
EMC
Complies with European EMC Directive 2004/108/EC
▪ IEC/EN 61326-2-1)
▪ CISPR Pub 11 Group 1, Class A
▪ AS/NZS CISPR 11
▪ ICES/NMB-001
19
FieldFox
ESD
▪ IEC/EN 61000-4-2, functional up to 20 kV test
Safety
Complies with European Low Voltage Directive 2006/95/EC
• IEC/EN 61010-1 2nd Edition
• Canada: CSA C22.2 No. 61010-1-04
• USA: UL 61010-1 2nd Edition
Environmental
Meets MIL-PRF-28800F Class 2 specification
Humidity
95% at 40 °C
Temperature
Operating
Non-operating
-10 ºC to +55 ºC
-51 ºC to 71ºC
Weight
6.2 lbs / 2.8 kg including battery
Dimensions (H x W x D)
11.5″ x 7.4″ x 2.8″ (292 x 188 x 72 mm)
Power
Power supply
External DC input: 15 to 19 VDC
External AC power adapter
Input
Output
Power consumption
Battery
Battery operating time
100 to 250 VAC, 50 to 60 Hz; 1.25 to 0.56 A
15 VDC, 4 A
12 W
6 cell Lithium Ion, 10.8 V, 4.6 A-h
4 hours
Languages
English, Chinese, French, Spanish, Japanese, Russian, German, and Italian
20
FieldFox
Configuration Information
N9912A FieldFox RF analyzer
FieldFox RF Analyzer base functions:
One port cable and antenna analyzer (4 GHz), broadband calibration, CalReady, standard
mechanical cal kit support. Measurements include: return loss, distance to fault (DTF),
one port cable loss and VSWR.
Standard accessories included N9912A:
AC/DC adapter; battery; soft carrying case; Quick Reference Guide; CD ROM with
FieldFox Data Link software and full manual
N9912A FieldFox options
Option 104
Option 106
Qption 110
Option 111
Option 230
Option 231
Option 235
Option 302
Option 303
4 GHz cable and antenna analyzer
6 GHz cable and antenna analyzer
Transmission measurement
QuickCal
4 GHz spectrum analyzer (requires Option 104)
6 GHz spectrum analyzer (requires Option 106)
Preamplifier for spectrum analyzer (requires Option 230 or 231)
External USB power sensor support
Network analysis capability
N9910X RF/MW handheld analyzer accessories
N9910X-800
N9910X-801
N9910X-802
N9910X-803
T-Calibration Kit, DC-6 GHz, Type-N(m)
T-Calibration Kit, DC-6 GHz, Type-N(f)
T-Calibration Kit, DC-6 GHz, 7/16 DIN(m)
T-Calibration Kit, DC-6 GHz, 7/16 DIN(f)
N9910X-810
N9910X-811
N9910X-812
N9910X-813
Rugged phase stable cable, Type-N(m) to Type-N(m), 5 ft
Rugged phase stable cable, Type-N(m) to Type-N(f), 5 ft
Rugged phase stable cable, Type-N(m) to Type-N(m), 12 ft
Rugged phase stable cable, Type-N(m) to Type-N(f), 12 ft
N9910X-820
N9910X-821
N9910X-843
N9910X-845
N9910X-860
N9910X-861
Antenna, directional, multiband, 800 to 2500 MHz, 10 dBi
Antenna, telescopic whip, 70 MHz to 1 GHz
Coaxial adapter, Type-N(m) to 7/16 DIN(f)
Adapter kit: Type-N(f) to 7/16 DIN(f), Type-N(f) to 7/16 DIN(m), Type-N(f) to Type-N(f)
Fixed attenuator, 40 dB, 100 W, DC-3 GHz, Type-N(m) to Type-N(f)
Fixed attenuator, 40 dB, 50 W, DC-8.5 GHz, Type-N(m) to Type-N(f)
N9910X-870
N9910X-872
N9910X-873
N9910X-874
N9910X-880
Extra battery
External battery charger
AC/DC adapter
External bias-tee, 2.5 MHz to 6 GHz, 1 W, 0.5 A
Extra soft carrying case with backpack and shoulder strap
N9910X-881
Hard transit case
N9910X-884
Extra N9912A shoulder strap
For more information go to: www.agilent.com/find/fieldfox
21
FieldFox
FieldFox Accessories
Bias-tees
Directional antenna
Antenna
Phase stable cable
100 Watt attenuator
Adapter kit
T-Cal kits
22
FieldFox
AC/DC adapter
Soft carrying case
External battery charger
Hard transit case
23
Remove all doubt
www.agilent.com/find/emailupdates
Get the latest information on the
products and applications you select.
Agilent Direct
www.agilent.com/find/agilentdirect
Quickly choose and use your test
equipment solutions with confidence.
Our repair and calibration services
will get your equipment back to you,
performing like new, when promised. You will get full value out of
your Agilent equipment throughout its lifetime. Your equipment
will be serviced by Agilent-trained
technicians using the latest factory
calibration procedures, automated
repair diagnostics and genuine parts.
You will always have the utmost
confidence in your measurements.
Agilent offers a wide range of additional expert test and measurement services for your equipment,
including initial start-up assistance,
onsite education and training, as
well as design, system integration,
and project management.
For more information on repair and
calibration services, go to:
www.agilent.com/find/removealldoubt
www.agilent.com
www.agilent.com/find/fieldfox
For more information on Agilent Technologies’
products, applications or services, please
contact your local Agilent office. The
complete list is available at:
www.agilent.com/find/contactus
Americas
Canada
Latin America
United States
(877) 894-4414
305 269 7500
(800) 829-4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Thailand
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
1 800 226 008
Europe & Middle East
Austria
01 36027 71571
Belgium
32 (0) 2 404 93 40
Denmark
45 70 13 15 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125 €/minute
Germany
07031 464 6333**
**0.14 €/minute
Ireland
1890 924 204
Israel
972-3-9288-504/544
Italy
39 02 92 60 8484
Netherlands
31 (0) 20 547 2111
Spain
34 (91) 631 3300
Sweden
0200-88 22 55
Switzerland
0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries:
www.agilent.com/find/contactus
Revised: July 17, 2008
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2008
Printed in USA, September 26, 2008
5989-8618EN
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising