Cino F700BT, F600BT Wireless Imager Reference Manual
The Cino FuzzyScan F600BT and F700BT Series Wireless Imagers provide outstanding reading performance and the convenience and freedom of mobility. These scanners can be used in PAIR mode (one to one) or PICO mode (multiple connections) with a smart cradle and legacy cabled interfaces to a host device. They can also be used in HID mode or SPP master/slave modes to connect with Bluetooth-enabled host devices.
PDF
Download
Document
Advertisement
Advertisement
WIRELESS IMAGER Reference Manual International Edition, Rev. A1 Wireless FuzzyScan Reference Manual Revision History Rev. No. Released Date Rev.A Oct. 16, 2009 Rev.A1 Oct. 22, 2009 Description First Release Page 6 Revise “Clone” function operation method. Page 68 Add “Save Configuration” and “Master Default” quick set commands. © Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied, reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written permission of Cino. All product information and specifications shown in this document may be changed without prior notice. Warranty Wireless FuzzyScan Reference Manual Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA procedures to return Cino for inspection. Regulatory FCC part 15B, FCC part 15C EN55022, EN55024, EN60950-1, EN301 489-1 & 489-17, EN300 328 CNS13438, CNS14336 LP0002 MIC T401 LED Eye Safety IEC60825-1, EN60825-1 Table of Contents Getting Started Getting Familiar with Your FuzzyScan Preparation before Using Decide Your Radio Link Mode Using FuzzyScan in PAIR Mode Using FuzzyScan in PICO Mode Using FuzzyScan in HID Mode Using FuzzyScan in SPP Mode Out-of-range Scanning/Presentation Scanning/Paging Function Batch Scanning (Inventory Mode) 1 2 3 4 5 7 8 10 11 Wireless FuzzyScan Reference Manual Configure Your FuzzyScan Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Control Keyboard Interface Control Serial Interface Control Wand/Laser Emulation Control Operation Control Condensed DataWizard 13 14 18 19 37 41 44 45 55 Appendix Symbology ID Table Keyboard Function Code Table ASCII Input Shortcut Link Mode Quick Set/Operation Mode Quick Set Host Interface Quick Set Option Codes System Commands 62 63 64 65 66 67 68 Getting Started Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge FuzzyScan 2.0 Imaging Technology and Bluetooth 2.1 EDR wireless technology, it not only provides outstanding reading performance, but also delivers the convenience and freedom of mobility. This document provides a quick reference for installation and operation purposes. The complete documentation is available at www.cino.com.tw. F700BT Series Scanner HB2110 Smart Cradle (Base) Center Indicator Side Indicators Paging/Reset Button Host Interface Port DC Power Jack Wireless FuzzyScan Reference Manual F600BT Series Scanner Link Indicator Status Indicator Beeper Scan Window Trigger Reset Button Battery Cavity End Cap HB2100 Charging Cradle (Base) Power Indicator Reserved Reserved DC Power Jack 1 Getting Started Preparation before Using Install the Battery Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity. Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end cap. The scanner will give 4 beeps when the battery pack is installed properly if the battery pack still has power. Secure the end cap with the screw provided, and make sure the end cap is secured properly before using the scanner. Charging the Battery There are 4 different power plugs in your power supply kit. Choose the appropriate local plug and slot it onto the power adapter cavity until it is locked. Wireless FuzzyScan Reference Manual Plug the AC power plug into the appropriate AC wall socket. Plug the DC power cord of the power supply unit into the DC power jack of the cradle. The smart cradle will issue the power on beeps and the center indicator will give one blue blink. If you use the charging cradle, please check the power indicator of the charging cradle turns steady blue. Place the scanner on the cradle. The status indicator of scanner will turn steady red if the battery is not fully charged. When the battery is fully charged, the status indicator of scanner will flash green at regular interval. Please charge the new battery pack for 8 hours prior to the first use. 2 Getting Started Decide Your Radio Link Mode The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to one connection) or PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled IT assets. Moreover, you are also able to use the scanner to work with Bluetooth-enabled host devices via SPP master/slave modes and HID mode. After losing the radio link, the scanner is capable of resuming the radio connection automatically while it returns to the communication coverage. But please note that this feature is not available in SPP slave mode. If you would like to change the radio link mode, you have to scan the “Uninstall” command to revert the scanner to uninstall state. PAIR Mode If the Bluetooth device is not available in your existing system, this is the simplest plug-and-play solution. In this mode, one scanner can only work with one smart cradle. The smart cradle not only provides the Bluetooth radio link with the scanner, but also offers the legacy cabled interfaces to the host device, including USB HID, USB COM, PS/2(DOS/V) Keyboard Wedge and RS232 Serial. Wireless FuzzyScan Reference Manual PICO Mode For the requirement of multiple connections, up to 7 scanners can be connected to one smart cradle concurrently. If you would like to un-pair all paired scanners and smart cradle, you can simply press and hold the paging/reset button of the smart cradle for over 3 seconds. If you just want to un-pair part of the paired scanners, please take those paired scanners to scan the “Uninstall” command one by one. HID Mode Through the most helpful HID service, the scanner can work like a Bluetooth keyboard. In this mode, the scanner is discoverable by the radio connection request issued by a remote host device. For security purpose, you will be requested to input the PIN Code to establish the Bluetooth connection in most time. SPP Master/Slave Mode Through the standard SPP service, the scanner can work like a serial input device. In SPP master mode, the scanner initiates the radio connection request to a remote slave device. In SPP slave mode, the scanner is discoverable by the radio connection request issued by a remote master device. 3 Getting Started Using FuzzyScan in PAIR Mode Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details. Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Please note that the scanner has been pre-paired already, if the scanner is shipped together with the smart cradle. You will see the link indicator of scanner gives 1 blue blink per 2.5 seconds and the middle indicator of smart cradle turns steady blue. If the scanner and smart cradle just give alternating red and green blinks (in “Uninstall” state), please follow steps 5-6 to establish the connection between the scanner and the smart cradle. Wireless FuzzyScan Reference Manual Scan “PAIR mode” command. The status indicator of scanner will turn steady red. Uninstall PAIR Mode Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process. When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner giving 1 blue blink per 2.5 seconds and the center indicator of the smart cradle turning steady blue. If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do” beeps to indicate pair failure, the scanner will return to uninstall state automatically. Scan the corresponding host interface quick set command to complete the installation. The default host interface of smart cradle is preset to USB HID. If you want to set the host interface to USB COM, you have to install the USB virtual COM driver into your host device before using the scanner. Please visit the CINO website to download the software driver. 4 Getting Started Using FuzzyScan in PICO Mode Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Ensure the side indicators of the smart cradle give alternative red and green blinks (in “Uninstall” state). If the smart cradle is paired with other scanners, you can press and hold the paging/reset button for over 3 seconds to un-pair all paired scanners. Then the smart cradle will return to uninstall state automatically. Prepare the scanners you desire to pair with smart cradle. Ensure the status indicator of each scanner give alternative red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command to un-pair the scanner. Then scan the “PICO mode” command, and the status indicator of scanner will turn steady red. Wireless FuzzyScan Reference Manual Uninstall PICO Mode Place the scanner on the smart cradle, then you will hear one short beep to indicate the pairing process is activated. The scanner will give continuous short clicks and the link indicator of scanner will flash blue quickly during the pairing process. When you hear 4 beeps in ascending tone, the pairing process is completed. You will see the link indicator of scanner giving 1 blue blink per 2.5 seconds, the center indicator of the smart cradle turning steady blue and its side indicators turning steady green. If the scanner pairing process failed or it’s not placed on the smart cradle within 20 seconds, you will hear 2 “Di-do Di-do” beeps to indicate pair failure, the scanner will return to uninstall state automatically. Scan the corresponding host interface quick set command to complete the installation. Please follow the same procedures to pair the other scanners with the smart cradle. For user’s convenience, the smart cradle will automatically assign the ID numbers to each scanner. After completed all pairing processes, you can scan the “System Information” command to check the assigned ID number of each scanner. 5 Getting Started Clone Function For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration” command. After that, please take the other paired scanners to scan “Clone” command one by one to clone the host interface related parameters. Please ensure to keep those paired scanners in connected status when you use the “Clone” function. Because the host interface related parameters can’t be cloned to the paired scanner in disconnected status. Save Configuration Clone The below host interface related parameters will be impacted by clone function: Data Transmission Parameter Serial Interface Control Field Delimiter Handshaking Protocol Data Transmission Format Intermessage Delay Host Interface Control Interfunction Delay Wireless FuzzyScan Reference Manual Host interface Selection Intercharacter Delay Keyboard Interface Control Baud Rate Keyboard Layout Data Frame Intermessage Delay Time Out Control Interfunction Delay Wand Emulation Control Intercharacter Delay Output Polarity Caps Lock Control Initial Signal State Caps Lock Release Control Margin Time Function Key Emulation Module Time Key Pad Emulation Narrow/Wide Ratio Upper/Lower Case Code39 Emulation 6 Getting Started Using FuzzyScan in HID Mode Ensure the battery is fully charged. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “HID Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds. Uninstall HID Mode Execute the Bluetooth Discovery procedure to find all available Bluetooth devices in your remote host. You will see ‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already. Double click the “CINO FxxxBT-xxxx” in the discovered Bluetooth device list. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting). You will see “Keyboard on CINO FxxxBT-xxxx”, and double click this HID service to establish the connection between the scanner and the remote host device. Wireless FuzzyScan Reference Manual The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state. Please note that if the scanner is not connected to the host device within 1 minute after scanning the “HID Mode” command, the scanner will go to sleep automatically. You just need to press the trigger to wake up the scanner to continue the installation. 1. The installation procedures vary on different remote host devices, operation systems and the Bluetooth software driver. Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the installation processes. 2. While using HID mode, beware of potential error in the data transmitted at the same time when radio link quality is poor. You are suggested to use the scanner under the communication coverage all the times. 7 Getting Started Using FuzzyScan in SPP Mode Establish SPP Master Connection Ensure the battery is fully charged. Please go to the folder of “Hardware” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes. Ensure a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of “Local Services” located in Bluetooth Advanced Setting. Click the “Add Serial Services” to add one more Bluetooth COM port. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “SPP Master Mode” command, and the status indicator of scanner will turn steady red. Wireless FuzzyScan Reference Manual Uninstall SPP Master Mode Scan a 12-character MAC address barcode, or scan 12 option codes and “FIN” command to confirm your inputs. The scanner will give continuous short clicks and the link indicator of the scanner will flash blue quickly during the radio connecting process. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting). The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state. Please note that if the scanner failed to connect to the host device within 30 seconds, the link indicator will give 3 blue blinks per 2 seconds. But the scanner is still continuing to discover the host device for another 30 seconds before go to sleep. In the interim, you still can scan “Uninstall” command to revert the scanner to uninstall state. If the scanner goes to sleep already, you just need to press the trigger to wake up the scanner to continue the installation. The installation procedures vary on different remote host devices, operating systems and the Bluetooth software driver. Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the installation processes. 8 Getting Started Establish SPP Slave Connection Ensure the battery is fully charged and a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of “Client Applications” located in Bluetooth Advanced Setting. Click the “Add COM Port” to add one more Bluetooth COM port. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “SPP Slave Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds. Uninstall SPP Slave Mode Execute the Bluetooth Discovery procedure to find all available Bluetooth device list in your remote host. You will see ‘’CINO FxxxBT-xxxx’’ is shown in the list if the scanner is successfully discovered already. Wireless FuzzyScan Reference Manual Double click the “CINO FxxxBT-xxxx” on the discovered Bluetooth devices. If the PIN Code or Passkey is requested for security connection, please enter “00000000” (default setting). You will see “Serial Port on CINO FxxxBT-xxxx”, and double click this SPP service to establish the connection between the scanner and the remote host device. The scanner will give 4 beeps in ascending tone to indicate the radio is connected. At the same time, the link indicator of scanner will give 1 blue blink per 2.5 seconds to indicate the scanner is in radio-connected state. Please note that if the scanner is not connected to the host device within 1 minute, the scanner will go to sleep. You can press the trigger to wake up the scanner to continue the installation. The installation procedures vary on different remote host devices, operating systems and the Bluetooth software drivers. Please consult your professional IT consultant to obtain necessary support if any problem has been encountered during the installation processes. 9 Getting Started Out-of-range Scanning When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection with the remote host device. If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of working range. All scanned data will be temporarily stored into the memory buffer until radio link resumed. Enable Out-of-range Scannning Disable Out-of-range Scanning ◆ In case of the scanner is out of working range, you will hear 4 beeps in descending tone to indicate the radio connection lost. The link indicator of scanner will give 3 blue blinks per 2 seconds. Once the scanner is back to working range, you will hear 4 beeps in ascending tone to indicate the radio connection rebuilt and the scanner will give 1 blue blink per 2.5 seconds. At the same time, all stored scanned data will be transmitted automatically right after the radio link is resumed. Presentation Scanning Wireless FuzzyScan Reference Manual The Presentation Scanning is designed for hand-free applications for user’s convenience. If the “Presentation Scanning Auto-sense” function is enabled, the scanner is capable of automatically switching to presentation mode when you place it onto the SmartStand or cradle. Enable Presentation Scanning Auto-sense Disable Presentation Scanning Auto-sense ◆ Paging Function The paging function is helpful for you to locate the paired smart cradle or scanner. If you would like to page the paired smart cradle, you can scan “Paging” command. If you would like to page the paired scanner, you can press the paging/rest button of the smart cradle no longer than 3 seconds. Paging Paging/Reset Button 10 Getting Started Batch Scanning (Inventory Mode) Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000 EAN-13 labels. It is an ideal cost-saving solution for inventory applications. Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning. You can scan and store the barcode data till the memory storage is full. If the storage is full, you will hear 2 long beeps and the status indicator will give 2 red blinks to indicate out of storage. To terminate the batch scanning, please scan the “Exit Batch Scanning” command. Enter Batch Scanning Exit Batching Scanning How to Transmit Stored Data The scanner is preset to scan the “Transmit Stored Data” command to transmit all stored data. During the transmission process, the scanner will give continuous short clicks and blue blinks. Then the scanner will give two short beeps after data transmission is completed. Wireless FuzzyScan Reference Manual Transmit Stored Data But you are still able to set the scanner to transmit the stored data by placing the scanner onto the cradle as well. Transmit Stored Data by Scanning Barcode Command ◆ Transmit Stored Data by Scanning Barcode or Placing Scanner onto Cradle Transmit Stored Data by Placing Scanner onto Cradle The scanner is preset to keep all the stored data until you scan the “Clear All Stored Data” command. But you are still able to change the setting to “Auto Delete Stored Data after Transmission” as well. Clear All Stored Data 11 Getting Started Auto Delete Stored Data after Transmission Keep Stored Data after Transmission ◆ If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the ‘’Delete Last Scanned Data’’ command, the last stored data can be deleted. Delete Last Scanned Data Using Quantity Feature If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the quantity barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage together with the barcode data. Quantity 0 Quantity 5 Wireless FuzzyScan Reference Manual Quantity 3 Quantity 8 Quantity 1 Quantity 6 Quantity 4 Quantity 9 Quantity 2 Quantity 7 There are two ways to output the stored barcode data and quantity information. Please refer to following for details: Stored data is transmitted as many times as the quantity indicated. Stored data is transmitted together with quantity information in two fields. Please scan “Enable Quantity Field Transmission” command to enable this function. The preset delimiter is “,“, but you are able to choose your desired one from FuzzyScan Wireless Reference Manual for details. Disable Quantity Field Transmission ◆ Enable Quantity Field Transmission 12 Configure Your FuzzyScan Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. System Command The System Command is the highest level bar code command which directs FuzzyScan to perform immediate operations, such as entering programming mode (PROGRAM), exiting programming mode (EXIT), listing system information (SYSLIST), recovering to factory preset configurations (M_DEFAULT), and so on. Please note that all system commands will take a few seconds to complete the operations. User must wait for the completion beeps before scanning another bar code. Wireless FuzzyScan Reference Manual Each programmable family and bar code command label is listed on the same page with major system commands. The detailed explanations and special programming flowchart are printed on facing or following pages. You can read the explanation and set the FuzzyScan concurrently. A supplemental bar code command menu incorporates the bar code command labels of System Command and Option Code. As you set the FuzzyScan, open the bar code command menu to find the option code page. You may scan the desired family code and option code to set FuzzyScan. If you want to change the programming family for multiple settings, you need only turn over the programming page to find next desired programming family. Family Code The Family Code is scanned to select the user desired programming family. FuzzyScan has already provided more than one hundred programming families to meet any specific requirements. Option Code The Option Codes is a set of bar code commands represented by “0–9”, “A–F” and finishing selection (FIN). For most setting, you must select at least one option code following the family code selection to set the desired parameter for the selected programming family. 13 Configure Your FuzzyScan If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details. Before setting the FuzzyScan, please also refer to the “Beeping Indications” listed in Appendix to understand the details of programming beeping indications. It will be very helpful for you to know the existing status while you are programming the FuzzyScan. Programming Procedures Wireless FuzzyScan Reference Manual As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan’s internal Flash Memory ASIC or non-volatile memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on. The programming procedures of FuzzyScan are designed as simple as possible for ease of setting. Most programming families take the Single Scan Selection programming procedure. But several programming families have more complex and flexible programmable options, and you must take Multiple Scans Selection, Cycling Scan Selection or Dual Level Selection to complete their programming procedures. Each kind of programming procedure is listed in the following pages for your reference. Please give careful attention to become familiar with each programming procedure. Conventions of Programming Menu Conventions Descriptions Factory Default Value P.C. Programming Category SS : Signle scan selection MS : Multiple scans selection CS : Cycling scan selection DS : Dual level scan selection 14 ( ) Necessary Option Code [ ] Selectable Option Code Configure Your FuzzyScan Program & End System List, Group & Master Default Scan “PROGRAM” Scan “SYSLIST” FuzzyScan will enter programming mode, and inhibit all non-programming functions. FuzzyScan will list the product information and revision number to host via selected host interface, Wireless FuzzyScan Reference Manual then issue the completion beeping. Scan “END” Scan “M_DEFAULT” FuzzyScan will exit programming mode, and store all parameters in Flash Memory ASIC or non-volatile memory, then issue the completion beeping. FuzzyScan will recover all programmable parameters into factory preset configurations, then issue the completion beeping. Please note that the FuzzyScan will take 3-4 seconds to store parameters in internal Flash Memory ASIC or non-volatile memory after you scan the “END”. Please don’t turn off the power before the completion beeping. It may destroy all configured parameters. 15 Configure Your FuzzyScan Single scan selection Multiple scans selection Scan Scan “PROGRAM” Scan One of Family Codes “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Select one of desired programming families. 1. Select one or several Select one option code of Scan One of Option Codes Enter programming mode. Scan One or Several Option Codes desired parameter. option codes to select desired parameters. 2. If it’s necessary, scan Yes Yes Want to select another Repeat Selection programming family? “FIN” to terminate Repeat Selection option code selection. Wireless FuzzyScan Reference Manual Want to select another No No Scan programming family? Scan Exit programming mode. “END” “END” 16 Exit programming mode. Configure Your FuzzyScan Cycling scan selection Dual level selection Scan “PROGRAM” Scan One of Family Codes Scan “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Cycling select one or Scan One of Option Codes (1st) Scan Several Option Codes several option codes of desired parameters as “Single” or “Multiple” (2nd) Scan One or Several Option Codes Wireless FuzzyScan Reference Manual Scan “FIN” Repeat Selection programming families. Select several option codes of desired parameters. 1. Select one or several parameters. 2. If it’s necessary, scan Finish cycling selection. “FIN” to terminate (If necessary) option code selection. Yes Want to select another Repeat Selection programming family? Want to select another programming family? No Scan “END” Select one of desired option codes of desired scans selection. Yes Enter programming mode. No Scan “END” Exit programming mode. 17 Exit programming mode. Configure Your FuzzyScan Host Interface Selection Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Host Interface Selection MS MS MS MS MS MS MS MS MS MS Parameter Selection IBM PS/2, 25-30 series keyboard wedge interface Standard/TTL RS-232 peer-to-peer serial Wand emulation USB Com Port Emulation PS/2 (DOS/V) direct link (keyboard replacement) PS/2 (DOS/V) keyboard wedge turbo mode PS/2 (DOS/V) keyboard wedge standard mode Laser emulation USB HID standard mode USB HID turbo mode 18 Option Code 02 06 08 09 10 13 14 17 18 19 Configure Your FuzzyScan Symbology Reading Control ♦ User Defined Symbol ID ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Symbol ID : 1 character DS Parameter Selection Code 128 (default=B) UCC/EAN-128 (default=C) UPC-A (default=A) EAN-13 (default=F) Codabar/NW-7 (default=D) Code 39/Code 32 (default=G) Code 93 (default=H) Standard/Industrial 2 of 5 (default=I) Interleaved 2 of 5 (default=J) Matrix 2 of 5 (default=K) China Postal Code (default=L) German Postal Code (default=M) IATA (default=O) Code 11 (default=P) MSI/Plessey (default=R) UK/Plessey (default=S) Telepen (default=T) GS1 DataBar (default=X) UPC-E (default=E) EAN-8 (default=N) Trioptic Code 39 (Default=W) UCC Coupon Extended Code (Default=Z) PDF417/Micro PDF417 (default=V) Codablock F (default=Y) Korea Post Code (default =a) 19 Option Code 2nd Option Code 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 26 (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) (1 character) Configure Your FuzzyScan Symbology Reading Control ♦ Symbology ID Transmission ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Symbology ID Transmission SS SS SS SS SS SS SS Parameter Selection Disable symbology ID transmission Enable prefix CINO symbology ID transmission Enable suffix CINO symbology ID transmission Enable both prefix and suffix CINO symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission 20 Option Code 0 1 2 3 4 5 6 Configure Your FuzzyScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection P.C Readable Symbology Setting SS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS Remember to scan “FIN” to terminate this selection. But if you select the Reference Manual “ Auto ”, FuzzyScan will terminate this Wireless FuzzyScan F_DEFAULT selection automatically. Parameter Selection Option Code 00 01 02 03 04 05 06 07 47 08 38 48 58 68 09 10 11 12 13 14 15 17 18 21 Auto Code 128 * UPC-A * UPC-E * EAN-13 * EAN-8 * Codabar/NW-7 * Code 39 * Trioptic Code 39 Standard/Industrial 2 of 5 Matrix 2 of 5 Interleaved 2 of 5 * China Postal Code German Postal Code Code 93 * Code 11 MSI/Plessey UK/Plessey Telepen GS1 DataBar (RSS-14) * IATA PDF417/Micro PDF417 Codablock F Korea Post Code If your application is reading known, limited bar code symbologies, you may increase the reading speed and decrease the reading error possibility by selecting those known symbologies only. Furthermore, to add the “Symbology ID” into the transmitted data is also helpful for applications to identify the specific symbology ID. Above symbologies marketed with * are enable as default. When you select “Auto”, the scanner only read those symbologies marked with * When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters. 21 Configure Your FuzzyScan Symbology Reading Control ♦ Code 39/Code 32 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Code 39 Family Setting SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS Disable Code 39 Enable Code 39 Select Standard Code 39 as primary format Select Full ASCII Code 39 as primary format Select Code 32 (PARAF, Italian Pharmaceutical) as primary format Disable start/stop symbol transmission Enable start/stop symbol transmission Disable Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering Enable Code 39 buffering 0 1 2 3 4 5 6 7 8 9 A B C D E Trioptic Code 39 Setting SS SS Disable Trioptic Code 39 Enable Trioptic Code 39 0 1 Code 39 Min. Length SS MS Default (01) 01-Maximum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 39 Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. 22 Configure Your FuzzyScan Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Codabar Setting SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS Disable Codabar Enable Codabar Select Codabar standard format Select Codabar ABC format Select Codabar CLSI format Select Codabar CX format Disable start/stop symbol transmission Enable ABCD/ABCD start/stop symbol transmission Enable abcd/abcd start/stop symbol transmission Enable ABCD/TN*E start/stop symbol transmission Enable abcd/tn*e start/stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Codabar Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 6 7 8 9 A B C D E FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Codabar Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 23 Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C UPC Family Setting SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS Parameter Selection Disable UPC-A Enable UPC-A Disable UPC-E Enable UPC-E Disable UPC-E expansion Enable UPC-E expansion Disable UPC standardization Enable UPC standardization Disable UPC numeric system Enable UPC numeric system Disable UPC-A check digit transmission Enable UPC-A check digit transmission Disable UPC-E check digit transmission Enable UPC-E check digit transmission Disable UPC “leading 1” portion Enable UPC “leading 1” portion 24 Option Code 0 1 2 3 4 5 6 7 8 9 A B C D E F Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C UPC Supplement Setting SS SS SS SS SS SS SS SS UPC-E & EAN-8 Expansion UPC-A/E Standardization UPC Lead 1 Numeric System Wireless FuzzyScan Reference Manual WPC Selection (UPC/EAN/CAN) UPC-A UPC-E EAN-13 EAN-8 Parameter Selection Option Code Select UPC without supplement digits Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output UPC Family Addenda Separator Off UPC Family Addenda Separator On 0 1 2 3 4 5 6 7 : Expand the 7-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13. : Expand the 7-digit UPC-E and 12-digit UPC-A to 8-digit EAN-8 to 13-digit EAN-13 with 1 zero insertion. : Enable to read UPC leading with the 1 numeric system, you must enable this option. Basic Length Disable Check Digit Disable Numeric System With 2-digit Addendum With 5-digit Addendum Enable Standardization Enable Expansion 12 7 13 8 -1 -1 -1 -1 -1 -1 NC NC +2 +2 +2 +2 +5 +5 +5 +5 +1 +1 NC NC 0 +5 0 +5 25 Configure Your FuzzyScan Symbology Reading Control ♦ EAN Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection EAN Setting SS SS SS SS SS SS SS SS SS SS SS SS Disable EAN-13 Enable EAN-13 Disable EAN-8 Enable EAN-8 Disable EAN-8 expansion Enable EAN-8 expansion Disable EAN-13 check digit transmission Enable EAN-13 check digit transmission Disable EAN-8 check digit transmission Enable EAN-8 check digit transmission Disable ISBN/ISSN Conversion reading check Enable ISBN/ISSN Conversion reading check 0 1 2 3 4 5 6 7 8 9 A B EAN Supplement Setting SS SS SS SS SS SS SS SS Select EAN without supplement digits Select EAN with only 2 supplement digits Select EAN with only 5 supplement digits Select EAN with 2/5 supplement digits Disable force supplement digits output Enable force supplement digits output EAN Addenda Separator Off EAN Addenda Separator On 0 1 2 3 4 5 6 7 26 Option Code Configure Your FuzzyScan Symbology Reading Control ♦ UCC Coupon Extended Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C UCC Coupon Extended Code SS SS Parameter Selection Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code Option Code 0 1 Wireless FuzzyScan Reference Manual UCC Coupon Extended Code When enabled, this parameter decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99”, and UCC/EAN-128 Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes. 27 Configure Your FuzzyScan Symbology Reading Control ♦ IATA & Interleaved 2 of 5 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection IATA Setting SS SS SS SS SS SS SS SS SS SS SS SS SS Disable IATA Enable IATA Select 15-digit fixed length IATA checking Select variable length IATA Disable check digit verification Enable check digit automatic verification Enable S/N checking digit verification only Enable CPN checking digit verification only Enable CPN, Airline and S/N check digit verification Disable check digit transmission Enable check digit transmission Disable start/stop symbol transmission Enable start/stop symbol transmission 0 1 2 3 4 5 6 7 8 9 A B C Interleaved 2 of 5 Setting SS SS SS SS SS SS SS SS SS Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Select Interleaved 2 of 5 as primary format Select German Postal Code as primary format No check character Validate USS check digit Validate OPCC check digit Disable check digit transmission Enable check digit transmission 0 1 2 3 4 5 6 7 8 28 Option Code Configure Your FuzzyScan Symbology Reading Control ♦ Code 25 Family Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 25 Setting SS SS SS SS SS SS SS SS SS SS Disable Standard/Industrial 2 of 5 Enable Standard/Industrial 2 of 5 Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable China Postal Code Enable China Postal Code Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Code 25 Family Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 6 7 8 9 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Wireless FuzzyScan Reference Manual Code 25 Family Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. We recommend that you select only one kind of Code 25 for reading, or set limited maximum and minimum reading length for reading, because the encoding algorithm of Code 25 isn’t very good. To decode all Code 25 automatically or to read variable length Code 25 will increase the error reading rate. 29 Configure Your FuzzyScan Symbology Reading Control ♦ Code 11 & Code 93 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 11 Setting SS SS SS SS SS SS SS Disable Code 11 Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission Code 11 Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 6 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 11 Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Wireless FuzzyScan Reference Manual Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 93 Setting SS SS SS SS Disable Code 93 Enable Code 93 Disable check digit transmission Enable check digit transmission Code 93 Min. Length SS MS Default (01) 01-Maximum 0 1 2 3 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 93 Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 30 Configure Your FuzzyScan Symbology Reading Control ♦ MSI/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection MSI/Plessey Setting SS SS SS SS SS SS SS Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission MSI/Plessey Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 6 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. MSI/Plessey Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Wireless FuzzyScan Reference Manual Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 31 Configure Your FuzzyScan Symbology Reading Control ♦ Code 128 & UCC/EAN 128 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 128/EAN-128 Setting SS SS SS SS SS SS Disable Code 128 and UCC/EAN-128 Enable Code 128 and UCC/EAN-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On Code 128/EAN-128 Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 2 3 4 5 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 128/EAN-128 Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Wireless FuzzyScan Reference Manual Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 32 Configure Your FuzzyScan Symbology Reading Control ♦ UK/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection UK/Plessey Setting SS SS SS SS SS SS SS SS Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 6 7 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Wireless FuzzyScan Reference Manual UK/Plessey Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 33 Configure Your FuzzyScan Symbology Reading Control ♦ Telepen Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Telepen Setting SS SS SS SS SS SS Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Telepen Max. Length SS MS Default (98) 98-Minimum FIN (2 digits) Wireless FuzzyScan Reference Manual Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 34 Configure Your FuzzyScan Symbology Reading Control ♦ GS1 DataBar Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection GS1 DataBar Setting SS SS SS SS SS SS Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 DataBar Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 FIN (2 digits) Only available for Expanded GS1 Databar. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Wireless FuzzyScan Reference Manual GS1 DataBar Max. Length SS MS FIN (2 digits) Default (74) 74-Minimum Only available for Expanded GS1 Databar. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 35 Configure Your FuzzyScan Symbology Reading Control ♦ Linear-stacked & Korea Post Code Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Composite Codes Setting SS SS SS SS Disable composite codes Enable composite codes UPC Composite Mode: UPC never linked UPC Composite Mode: UPC always linked 0 1 2 3 PDF417/MicroPDF417 Setting SS SS SS SS Disable PDF417 Enable PDF417 Disable MicroPDF417 Enable MicroPDF417 0 1 2 3 Codablock F Setting SS SS Disable Enable 0 1 Korea Post Code Setting SS SS Disable Enable 0 1 Length fixed in 6 characters. Composite Codes Setting If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected. If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected. 36 Option Code Configure Your FuzzyScan Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Keyboard Layout SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS Parameter Selection Option Code 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 99 USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Latin America (QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany (QWERTY) Iceland (QWERTY) Japan (DOS/V) Universal * (see note) The “Universal Selection” is only for PC/AT, PS/VP, PS/2 and compatible ones in DOS or Windows environment which can perform unique output without Caps Lock on/off (Output Style) concern. All transmitted data will follow the original full ASCII form. You also need not worry about the upper/lower case control. Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as premble or postamble. To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first. Keyboard Interface Message String : Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix 1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character 37 Configure Your FuzzyScan Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Record Suffix SS SS SS SS SS SS None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) Preamble SS MS None 1-15 characters Option Code 0 1 2 3 4 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Wireless FuzzyScan Reference Manual Maximum 15-character input; scan “FIN” to terminate this selection. Caps Lock Control SS SS SS “Caps Lock Off” State “Caps Lock On” State Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only) 0 1 2 Caps Lock Release Control SS SS “Caps Lock On, Caps Off” “Caps Lock On, Shift Off” 0 1 The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don’t perform the above functions for you. Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch. 38 Configure Your FuzzyScan Keyboard Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Interfunction Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Wireless FuzzyScan Reference Manual Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string. Intermessage Delay, Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes. 39 Configure Your FuzzyScan Keyboard Interface Control ♦ Emulation Setting & Upper/Lower Case Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Function Key Emulation SS SS Parameter Selection Enable ASCII 00-31 code as keyboard function code output Ctrl-Output Option Code 0 1 Wireless FuzzyScan Reference Manual Refer to Appendix – Keyboard Function Code Table for details. Key Pad Emulation SS SS Disable key pad emulation Enable numeric output as key pad (Num Lock On) output 0 1 Upper/Lower Case SS SS SS SS Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case) 0 1 2 3 40 Configure Your FuzzyScan Serial Interface Control ♦ Record Suffix, Preamble ,Postamble Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C STX/ETX Control SS SS Parameter Selection Option Code Disable STX/ETX transmission Enable STX/ETX transmission 0 1 STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface. Record Suffix SS SS SS SS SS SS MS None CR (0DH) LF (0AH) CRLF (0D0AH) TAB (09H) SPACE (20H) User defined character (1 character) Preamble SS MS None 1-15 characters 0 1 2 3 4 5 6, (00-7F) FIN [00-7F], [FIN] Wireless FuzzyScan Reference Manual Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Serial Interface Message String (RS232, USB COM) : STX Preamble Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble ETX Record Suffix 1 character 1-15 characters 2-3 digits 1 or 2 characters Variable length 1 or 2 characters 1-15 characters 1 character 1 character 41 Configure Your FuzzyScan Serial Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Interfunction Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Wireless FuzzyScan Reference Manual Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string. Intermessage Delay, Intercharacter Delay and Interfunction Delay cannot be only worked under SPP and HID modes. 42 Configure Your FuzzyScan Serial Interface Control ♦ Protocol, Baud Rate, Data Frame & Time Out Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Handshaking Protocol SS SS SS SS None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) Baud Rate (BPS) SS SS SS SS 38.4K BPS 19.2K BPS 9600 BPS 4800 BPS 2400 BPS 1200 BPS 600 BPS 300 BPS 0 1 2 3 4 5 6 7 Data Frame SS SS SS SS SS SS SS SS 8, None, 1 8, Odd, 1 8, Even, 1 8, Space, 1 8, Mark, 1 8, None, 2 7, Odd, 1 7, Even, 1 7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2 0 1 2 3 4 5 6 7 8 9 A B C D E Time Out Control SS SS SS MS None 200 mseconds 500 mseconds 1 second 2 seconds 5 seconds User defined value (seconds) 0 1 2 3 4 5 6, (2 digits) 0 1 2 3 When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK. The Time Out Control is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer. 43 Configure Your FuzzyScan Wand/Laser Emulation Control ♦ Output Polarity, Signal State, Margin/Module Time, etc. ♦ PROGRAM F_DEFAULT Family Code Selection P.C Output Polarity SS SS Parameter Selection Option Code High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) 0 1 Determine the output voltage level for both bar and space. Initial Signal State SS SS High Level (5Vdc) Low Level (0Vdc) 0 1 Wireless FuzzyScan Reference Manual Determine the initial state of output voltage level. Margin Time SS SS SS SS 10 msec. 15 msec. 20 msec. 25 msec. 30 msec. 50 msec. 100 msec. Delay time before data transmission 0 1 2 3 4 5 6 Module Time SS SS SS Extremely short Short Medium Long 0 1 2 3 Narrow/Wide Ratio SS SS SS 1:2 1:2.5 1:3 0 1 2 Code 39/Code 128 Emulation SS SS SS SS SS Disable standard Code 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation Enable Full ASCII Code 39 emulation Enable Code 128 emulation 0 1 2 3 4 Time base of minimum narrow bar [ Code 39 Skip ] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read, they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped. [ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space. 44 Configure Your FuzzyScan Operation Control ♦ Operation Mode, Presentation Scanning Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Operation Mode SS SS Trigger mode Presentation mode 1 2 Presentation Scanning Auto-sense SS SS Disable Enable 0 1 Wireless FuzzyScan Reference Manual Trigger Mode The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code. Presentation Mode Presentation mode uses ambient light to detect bar codes. The LEDs are off for ambient conditions until a change occurs in the scanner’s field of view. Then the LEDs turn on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work properly. The Presentation Scanning Auto-sense can switch between presentation mode and trigger mode automatically while working with SmartStand or cradle. 45 Configure Your FuzzyScan Operation Control ♦ Buzzer, Indicator, Vibrator, Inverse Reading, Dollar Sign ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Buzzer Tone Adjust SS SS SS SS SS SS SS Buzzer tone – mute Buzzer tone – low Buzzer tone – medium Buzzer tone – high Buzzer tone - extremely high Power-on beep No power-on beep 0 1 2 3 4 5 6 Power On Indicator SS SS SS Disable (LED off) LED steady on LED flash 0 1 2 Vibrator Control SS SS Disable Enable 0 1 Wireless FuzzyScan Reference Manual Optional function, only available for vibrator model. Inverse Reading SS SS Disable Enable 0 1 Dollar Sign Control SS SS SS SS SS Dollar sign output as “ $ “ Dollar sign output as “¥“ Dollar sign output as “ € “ Dollar sign output as “ £ “ Dollar sign output as “ ¢ “ 0 1 2 3 4 46 Configure Your FuzzyScan Operation Control ♦ Flash Duty Cycle, Redundancy, Delay Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Flash Duty Cycle SS SS SS SS 1/2 duty cycle 2/3 duty cycle 3/4 duty cycle 4/5 duty cycle 0 1 2 3 Redundancy (Scan Voting) SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading. 0 1 2 3 4 5 Reread Delay SS SS SS SS SS SS Disable Immediate time out Short time out Medium time out Long time out Force verification 0 1 2 3 4 5 Good Read Delay SS SS SS SS SS SS SS None 200 msec. 500 msec. 1 sec. 1.5 sec. 2 sec. 3 sec. 0 1 2 3 4 5 6 The Flash Duty Cycle is designed to control the flashing frequency of the light source. The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted. The Reread Delay is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification will not allow reading of the same bar code twice. This Good Read Delay is the minimum amount of time before the scanner can read another bar code. 47 Configure Your FuzzyScan Operation Control ♦ Time-out Setting, Good Read Beep Duration ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Auto Power Off Duration SS SS SS SS Short Medium Long Extremely long 0 1 2 3 Hands Free Time-out SS SS SS SS Short Medium Long Extremely long 0 1 2 3 Good Read Duration SS SS SS SS Short Medium Long Extremely long 0 1 2 3 The Auto Power Off Duration is a pre-defined power off time out counter for Presentation Mode. The scanner keeps the light source on till the pre-defined auto power off duration is up. You can adjust this parameter to meet your own application requirement. The Presentation Mode is referred to as “hands free” modes. The hands free mode will be automatically changed to manual trigger mode if you remove the scanner from stand. The manual trigger mode will be changed to hands free mode if you place the scanner back to stand. You can set the time for scanner to remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is up (if there have been no further trigger pulls), the scanner reverts to the original hands free mode. 48 Configure Your FuzzyScan Operation Control ♦ SmartStand Power Off Time-out ♦ PROGRAM F_DEFAULT Family Code Selection P.C SmartStand Power Off Timeout SS SS SS Parameter Selection 3 mins 5 mins 10 mins Option Code 0 1 2 Only available for FuuzzyScan Laser model Wireless FuzzyScan Reference Manual The SmartStand Power Off Timeout is a pre-defined duration for scanner placed in SmartStand. While the scanner is placed in SmartStand, the scanner’s built-in sensor will switch the scanner from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be off when the pre-defined power off duration is up. 49 Configure Your FuzzyScan Operation Control ♦ Out-of-range Scanning, Sleep Time-out Control ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Out-of-range Scanning SS SS Disable Enable 0 1 Link Supervision Time-out SS SS SS SS SS 1 sec 3 secs 5 secs 7 secs 9 secs 0 1 2 3 4 Wireless FuzzyScan Reference Manual Only available in PAIR & PICO modes Sleep Time-out of Connect State SS MS 6 (x5) minutes 0-99 (x5) minutes FIN (2 digits) Sleep Time-out of Disconnect State SS MS 1 minute 0-99 minutes FIN (2 digits) Out-of-range Scanning When radio link is built between the scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode data. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection. You can enable the Out-of-range Scanning function to continue scanning barcode data into memory buffer until radio link resumed. The Link Supervision Time-out is a pre-defined radio link supervision timeout setting. The scanner will supervise the radio link status every preset seconds. The Sleep Time-out Control can be set under radio connection or disconnection state. If the scanner is not used within the preset time-out duration, it will automatically enter “Sleep State” for power saving purpose. You are able to disable this function by setting the time-out duration to “0”. 50 Configure Your FuzzyScan Operation Control ♦ Batch Scanning Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Batch Scanning Link Control SS SS Radio disable Radio enable 0 1 Stored Data Transmission SS SS SS All On cradle Scan barcode 0 1 2 Delete Stored Data after Transmission SS SS Disable Enable 0 1 The Batch Scanning Link Control is a pre-defined radio option to control the radio-on or radio-off status under batch scanning operation. Please note that if the radio disable is activated, the radio link will be disconnected once you enter batching scanning. The radio link will be resumed when you transmit the stored data or exit batch scanning. The Stored Data Transmission is a pre-defined approach when you want to transmit the scanned data under batch scanning operation. You can transmit the scanned data by placing the scanner onto the cradle or scanning “Transmit Stored Data” command, or by either one of both methods. In batching scanning, the default setting of Delete Stored Data after Transmission is disable. The scanner will keep all stored data after transmission until you scan the “Clear All Stored Data” command. You are also able to delete all stored data after transmission automatically by enabling this function. 51 Configure Your FuzzyScan Operation Control ♦ Batch Scanning Data Transmission Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Field Delimiter SS SS SS SS SS SS None , SPACE – . User define Batch Data Quantity Output Format SS SS As many times as the quantity indicates <Quantity><Field Delimiter><Scanned Data> 0 1 Data Transmission Format SS SS SS Disable (scanned data only) Leading with MAC address (MAC address and scanned data) Leading with ID No. (scanner ID and scanned data) 0 1 2 0 1 2 3 4 5, [00-7F] Only available for RS232, USB HID and USB COM interface in PAIR & PICO modes The Field Delimiter is used to separate the specific information and scanned data into two fields. You can choose desired delimiter format. The Batch Data Quantity Output Format If you want to input the quantity information of barcode data, you can enter the quantity from 1 to 9999 by scanning the quantity barcodes right after you scanned the barcode data. The quantity information will be stored into the memory storage together with the barcode data. There are two ways to output the stored barcode data and quantity information. In PICO mode, up to 7 scanners can be connected with one smart cradle. The Data Transmission Format can help user to identify the source of the transmitted data. You can choose to transmit the scanned data leading with MAC address or pre-assigned ID. Example format: <MAC address><Field Delimiter><Data> or <ID><Field Delimiter><Data>. 52 Configure Your FuzzyScan Operation Control ♦ Bluetooth Device Name & Security Setting♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Bluetooth Device Name SS MS Default device name User define, 1-14 characters FIN [00-7F], FIN Bluetooth PIN Code SS MS Default Bluetooth PIN Code User define, 1-8 numbers FIN [30-39], FIN Bluetooth Authentication SS SS Disable Enable 0 1 The default Bluetooth Device Name is “CINO FxxxBT-xxxx”, you will be able to change the device name by scanning HEX values (1-14 characters). The default Bluetooth PIN Code is “00000000”, you will be able to change the PIN Code by scanning HEX values (1-8 numbers). The Bluetooth Authentication You can enable or disable the Bluetooth Authentication between the scanner and remote host device. If this function is enabled, when the scanner wants to connect itself and sends the data to the host device, the host device has to return a link key shared between the scanner and the host device. 53 Configure Your FuzzyScan Operation Control ♦ Bluetooth Other Settings ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code HID Link Quality Setting SS SS Disable Enable 0 1 Bluetooth Power Saving Mode SS SS Disable Enable 0 1 Wireless FuzzyScan Reference Manual The HID Link Quality Setting While using the HID radio link mode, some errors may occur during the data transmission when the radio link is disconnected. You can enable this function to prevent such error from occurring. The Bluetooth Power Saving Mode Bluetooth module will enter low consumption mode when you enable this function. 54 Configure Your FuzzyScan Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM F_DEFAULT Family Code Selection P.C Preamble SS MS Parameter Selection None 1-15 characters Option Code FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Data Length Transmission SS SS Disable Enable 2 digits data length transmission 0 1 If data length exceeds 99, 3-digit data length will be transmitted. Wireless FuzzyScan Reference Manual Symbology ID Transmission SS SS SS SS SS SS SS Disable symbology ID transmission Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Enable prefix AIM symbology ID transmission Enable suffix AIM symbology ID transmission Enable both prefix and suffix AIM symbology ID transmission 0 1 2 3 4 5 6 DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard, you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help you to arrange the transmission of scanned data to any specific format without software modification. Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT/2000/XP environment. A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with ease. Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance. 55 Configure Your FuzzyScan Condensed DataWizard ♦ Data Formatter Setting ♦ PROGRAM Family Code Selection P.C Formatter Control SS MS MS 1st Insertion SS DS 2nd Insertion Reference Manual 3rd Insertion Wireless FuzzyScan F_DEFAULT 4th Insertion SS DS SS DS SS DS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) [1-3 characters], [FIN] 2-digits identified position; max. 3 insertion characters position Disable Enable FIN (2 digits) 2-digits identified position; max. 3 insertion characters position Disable Enable FIN (2 digits) 2-digits identified position; max. 3 insertion characters position Disable Enable FIN (2 digits) 2-digits identified position; max. 3 insertion characters position [1-3 characters], [FIN] [1-3 characters], [FIN] [1-3 characters], [FIN] The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position. While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbolology ID or Record Suffix. All of the above programmable parameters perform the same function depending on your setting. Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 37 for details. Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 56 Configure Your FuzzyScan Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Verifier Control SS MS MS Identified Data Length SS MS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) Determine the identified data length for verification. 1st Identified Character Wireless FuzzyScan Reference Manual 2nd Identified Character 3rd Identified Character SS DS SS DS SS DS Disable Enable FIN (2 digits) 2-digits checking position; 1 identified character position Disable Enable FIN (2 digits) 2-digits checking position; 1 identified character position Disable Enable FIN (2 digits) 2-digits checking position; 1 identified character position [00-7F] [00-7F] [00-7F] The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter. All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data. The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 37 for details. Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value. 57 Configure Your FuzzyScan Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM Family Code Selection P.C Replacer Control SS MS MS 1st Replacement SS DS 2nd Replacement Reference Manual 3rd Replacement Wireless FuzzyScan F_DEFAULT SS DS SS DS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) [00-7F] 2-digits identified position; 1 replacement character position Disable Enable FIN (2 digits) 2-digits identified position; 1 replacement character position Disable Enable FIN (2 digits) 2-digits identified position; 1 replacement character position [00-7F] [00-7F] The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for replacer control, and provides Multiple Position Replcement in the identified position. All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 37 for details. Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find mathced HEX value. 58 Configure Your FuzzyScan Condensed DataWizard ♦ Data Organizer Setting ♦ PROGRAM Family Code Selection P.C Organizer Control SS MS MS 1st Organization SS DS 2nd Organization Reference Manual Include/Exclude Control Wireless FuzzyScan F_DEFAULT SS DS SS DS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) 2-digits identified position; Forward/backward data transmission setting position direction Disable Enable FIN (2 digits) 2-digits identified position; Forward/backward data transmission setting position direction Transmitted data excluded the data of identified position Transmitted data included the data of identified position 0 (Forward) 1 (Backward) 0 (Forward) 1 (Backward) 0 1 The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data including or excluding the data of identification position. Please refer to the application example listed in page 37 for details. While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix. Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 37 for details. Please note that all “Character” input should be referred to the ASCII/HEX Table. 59 Configure Your FuzzyScan [Data Verifier, Data Replacer, Data Organizer] Select a Bar Code Symbology If there is a 11-character data string, please refer to the following to calculate the actual position for identification. Wireless FuzzyScan Reference Manual You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below. Code 128 : 01 EAN-8 : 05 Code 93 : 09 UCC/EAN 128 : 31 EAN-8 with 2 supple : 35 Code 11 : 10 UPC-A : 02 EAN-8 with 5 supple.: 45 MSI/Plessey : 11 UPC-A with 2 supple.: 32 Codabar/NW-7 : 06 UK/Plessey : 12 UPC-A with 5 supple.: 42 Code 39 : 07 Telepen : 13 UPC-E : 03 Code 32 : 37 GS1 Data Bar : 14 UPC-E with 2 supple.: 33 Trioptic Code 39: 47 IATA : 15 UPC-E with 5 supple.: 43 Matrix 2 of 5 : 38 Coupon Code : 16 EAN-13 : 04 Interleaved 2 of 5 : 48 PDF417/MicroPDF417: 22 EAN-13 with 2 supple. : 34 China Postal Code : 58 Codablock: 23 EAN-13 with 5 supple. : 44 German Postal Code : 68 Korea Post Code: 26 X X X X X X X X X X X 00 01 02 03 04 05 06 07 08 09 10 Application Example If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification: Apply only Interleaved 2 of 5 to the condensed DataWizard. Check bar code is actually with 16-digit length. Allow bar code output whose date code is leading with “9”. Position Calculation Three outputs with “TAB” suffix. [Data Formatter] The date code output should skip “9” and replaced it by “A”. If there is a 5-character input data string, refer to the following to calculate the actual position for insertion: X 00 X 01 X 02 X 03 The serial number output should be led with “SN”. X 04 The unit price output should be skipped the first 2 digits. 05 Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6 Actual Output : A81025[TAB]SN123456[TAB]76[TAB] 60 Configure Your FuzzyScan Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Replacer Control” and set bar code symbology to “48”. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5). Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A). Scan “Identified Data Length” and set the length to “16”. Scan “1st Identified Character” and set the identified position to “00”, then set the identified character to “39” (Hex Code of 9). [Data Organizer] Scan “Organizer Control” and set bar code symbology to “48”. Wireless FuzzyScan Reference Manual [Data Formatter] Scan “Formatter Control” and set bar code symbology to “48”. Scan “1st Organization” and set the identified position to “16”, then set the data transmission to “0” (forward). Scan 1st Insertion” and set the identified position to “06”, then inserted characters to “09” (Hex Code of TAB), “53” (Hex Code of S), “4E” (Hex Code of N). Scan “2nd Organization” and set the identified position to “17”, then set the data transmission to “1” (backward). Scan “2nd Insertion” and set the identified position to “12”, then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection. Scan “END” (Exit) to terminate the programming. [Important Notice] Scan “3rd Insertion” and set the identified position to “16”, then inserted character to “09”. In the final, you must scan “FIN” (Finish) code to terminate this selection. Please note that Condensed DataWizard will follow the preset working flow as below: Verifier Formatter Replacer Organizer So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter. 61 Appendix Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character Cino ID Code Family Primary Format AIM ID Code Code Modified Character Character Character UPC-A UPC-A with 2 supple. A UPC-A with 5 supple. UPC E UPC-E UPC-E with 2 supple. Cino ID E EAN/JAN-8 1 EAN/JAN-8 with 2 supple. 2 EAN/JAN-8 with 5 supple. m EAN/JAN 2 Reference Manual Wireless FuzzyScan Codabar Code 25 IATA Code 128 B UCC/EAN-128 C C Code Code Modified Character Character Character N E 1 4 2 EAN/JAN-13 EAN/JAN-13 with 2 supple. m F E EAN/JAN-13 with 5 supple. Example: A UPC-A bar code 012345678950 with 2 supplement 12 is transmitted as ]E0012345678950]E112 Code 128 Primary Format m 1 UPC-E with 5 supple. Code Family AIM ID 1 2 Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is transmitted as ]E449123562]E212345 m Code 93 Code 93 H G m 1 Code 11 Code 11 P H m Codabar/NW-7 D F m MSI/Plessey MSI/Plessey R M m Standard/Industrial 2 of 5 I S 0 UK/Plessey UK/Plessey S P 0 Matrix 2 of 5 K X 0 Telepen Telepen T B m Interleaved 2 of 5 J I m X e 0 Code 39 G A m Code 39 Trioptic W X 0 Code 32 G A 0 PDF417 PDF417/Micro PDF417 V L 0 Codablock Codablock F Y O 0 Korea Post Korea Post Code a X 0 China Postal Code L X 0 German Postal Code M I 3 IATA O R m UCC Coupon Code Z Example : A UPC-A 512345678900 + UCC/EAN-128 81010123451297 UCC Coupon bar code is transmitted as]E0512345678900]C181010123451297 Example: A EAN-13 9923456789019 + UCC/EAN-128 81010123451297 bar code is transmitted as ]E09923456789019]C181010123451297 GS1 DataBar GS1 Databar Compsoite Composite Code Code 39 Remark: Above examples are given for the transmission of AIM ID. 62 Appendix Wireless FuzzyScan Reference Manual Keyboard Function Code Table No. ANSI ASCII 00 NUL 00H 01 SOH 02 Key Function No. ANSI ASCII Key Function RESERVED 16 DLE 10H F7 01H CTRL (Left) 17 DC1 11H F8 STX 02H ALT (Left) 18 DC2 12H F9 03 ETX 03H SHIFT 19 DC3 13H F10 04 EOT 04H CAPS LOCK 20 DC4 14H F11 05 ENQ 05H NUM LOCK 21 NAK 15H F12 06 ACK 06H ESC 22 SYN 16H INS (Insert) (Edit) 07 BEL 07H F1 23 ETB 17H DEL (Delete) (Edit) 08 BS 08H BACK SPACE 24 CAN 18H HOME (Edit) 09 HT 09H TAB 25 EM 19H END (Edit) 10 LF 0AH F2 26 SUB 1AH PAGE UP (Edit) 11 VT 0BH F3 27 ESC 1BH PAGE DOWN (Edit) 12 FF 0CH F4 28 FS 1CH UP (Edit) 13 CR 0DH ENTER (CR) 29 GS 1DH DOWN (Edit) 14 SO 0EH F5 30 RS 1EH LEFT (Edit) 15 SI 0FH F6 31 US 1FH RIGHT (Edit) To emulate the keyboard function key input for user definable parameters, user must configure actual content using the Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP, COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines. 63 Appendix ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. HEX/ASCII Reference Table H 0 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p Example: 1 SOH DC1 ! 1 A Q a q If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference. 2 STX DC2 " 2 B R b r 3 ETX DC3 # 3 C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB ' 7 G W g w 8 BS CAN ( 8 H X h x 9 HT EM ) 9 I Y i y A LF SUB * : J Z j z B VT ESC + ; K [ k { C FF FS , < L \ l | D CR GS - = M ] m } Scan the system command – FIN (Finish) to terminate Preamble setting. E SO RS . > N ^ n ~ F SI US / ? O _ o DEL Scan the system command – End to exit the programming mode for normal operation. Example : ASCII “A” → HEX “41”; ASCII “a” → “61” L Scan the system command – PROGRAM listed on page 3-24 to enter programming mode. Scan family code – PREAMBLE to select this family. Refer to the Hex/ASCII Table, you will find the HEX value of “$” is 24. Scan the option code – 2 listed on the fold out back cover. Wireless FuzzyScan Reference Manual Scan the option code – 4 listed on the fold out back cover. : High Byte of HEX Value : Low Byte of HEX Value 64 Appendix Link Mode Quick Set Uninstall SPP Slave Mode PAIR Mode HID Mode SPP Master Mode PICO Mode Wireless FuzzyScan Reference Manual Operation Mode Quick Set Trigger Mode Presentation Mode 65 Appendix Host Interface Quick Set (Work with Smart Cradle only) RS232 Serial PS/2 (DOS/V) KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode USB HID Turbo Mode Wireless FuzzyScan Reference Manual USB Com Port Emulation 66 Appendix Option Codes 0 8 4 C 1 9 5 D 2 A 6 E Wireless FuzzyScan Reference Manual 3 B 7 F FIN (Finish) END (Exit) 67 Appendix System Commands PROGRAM (Enter Programming Mode) Save Configuration Sleep FIN (Finish) Clone Paging END (Exit Programming Mode) Factory Default Wireless FuzzyScan Reference Manual PowerTool Host Link System Information List (SYSLIST) Master Default Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the scanner will revert to uninstall state). Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), Wand/Laser Emulation Control, Bluetooth Device Name, Bluetooth PIN Code, and Out-of-range Scanning, the rest of parameters will be returned to default value (The radio link is still keep on). Save User Default User Default 68 FuzzyScan Wireless Reference Manual CINO GROUP PC WORTH INT’L CO., LTD. www.cino.com.tw ">
Advertisement
Key features
- Bluetooth 2.1 EDR wireless technology
- FuzzyScan 2.0 Imaging Technology
- PAIR, PICO, HID, SPP modes
- Out-of-range Scanning
- Presentation Scanning
- Batch Scanning up to 20,000 EAN-13 labels
Frequently asked questions
The paging function is helpful for locating the paired smart cradle or scanner. To page the paired smart cradle, scan the "Paging" command. To page the paired scanner, press the paging/rest button of the smart cradle for less than 3 seconds.
To clear all stored data during batch scanning, scan the “Clear All Stored Data” command.
To delete the last scanned data during batch scanning, scan the “Delete Last Scanned Data” command.
To enable the quantity field during batch scanning, scan the “Enable Quantity Field Transmission” command.