Elf SSD Modem Module »

Elf SSD Modem Module »
INSTALLATION
Single Slot Dock Modem Module
Installation of the Modem Module should always be made
with power OFF!
NOTE
Read this manual carefully before performing any type of
connection from the terminal to a host PC using the
Single Slot Dock Modem Module.
The user is responsible for any damages caused by
incorrect use of the equipment or by inobservance of the
indication supplied in this manual.
CAUTION
MODEM CONNECTION
1.
Connect the telephone line to the Modem port on the Module.
2.
Press the selection switch until the module selection LED is on.
3.
Insert the Datalogic mobile computer into the dock.
A
To install the Modem Module:
1.
remove the label covering the communication module connector
on the bottom of the Single Slot Dock, as shown in the figure
below:
Do not attempt to disassemble the Single Slot Dock
Modem Module, as it does not contain parts that can be
repaired by the user. Any tampering will invalidate the
warranty.
C
NOTE
B
The Single Slot Dock Modem Module is a snap-on module for Single Slot
Docks which, paired with a Datalogic mobile computer, builds a reading
system for the collection, decoding and transmission of barcoded data.
Figure 3 – Modem Connection
The Single Slot Dock Modem Module is a Modem communication adapter
for the mobile computer.
Key:
2.
B
C
plug the Modem Module into the Single Slot Dock until the snaps
clicks, as shown in the figure below:
A)
Single Slot Dock with Modem Module
B)
Phone line to remote computer
C)
94ACC1381 Power Adapter
ANALOG TELECOM SAFETY WARNINGS
A
E
D
Figure 1 – Single Slot Dock Modem Module General View
Key:
A)
Module selection LED
B)
Snaps
C)
Contacts for connection to Single Slot Dock
D)
Modem port
E)
Modem/RS232 selection switch
822001030
1.
Never install telephone wiring during a lightning storm.
2.
Never install a telephone jack in wet locations unless the jack is
specifically designed for wet locations.
3.
This product is to be used with UL and cUL listed computers.
4.
Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface.
5.
Use caution when installing or modifying telephone lines.
6.
Avoid using a telephone during an electrical storm. There may be a
remote risk of electrical shock from
7.
Do not use a telephone in the vicinity of a gas leak.
8.
To reduce the risk of fire, use only 26 AWG or larger
telecommunication line cord.
9.
This product must be disconnected from its power source and
telephone network interface when servicing
lightning.
Figure 2 – Single Slot Dock Modem Module Installation
LED INDICATORS
FCC COMPLIANCE
Power LED Status Indicator
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Color
Status
Off
RS232 mode selected
Yellow
Modem mode selected
TECHNICAL FEATURES
Communication Features
Interface
Modem
Data Standard
V.92
Data Rate
56 Kbps
Physical Features
Dimensions
110 x 140 x 36 mm
4,3 x 5,5 x 1,4 in
Weight (without
185 g / 6,5 oz
connection cables)
Indicators
Module selection LED
Environmental Features
Working temperature
0° to +50°C / 32° to 122°F
Storage temperature
-20° to +70°C / -4° to 158°F
Humidity
95% without condensation
Electrostatic discharge
4 KV contact / 8 KV air
EN 61000-4-2
Modifications or changes to this equipment without the expressed written
approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference which may cause undesired operation.
Datalogic Mobile S.r.l.
Via S. Vitalino 13
40012 - Lippo di Calderara
Bologna - Italy
10
dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
MODULE, MODEM, SINGLE SLOT DOCK
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine Modelle
y todos sus modelos
sono conformi alle Direttive del Consiglio Europeo sottoelencate:
are in conformity with the requirements of the European Council Directives listed below:
sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous:
den nachstehenden angeführten Direktiven des Europäischen Rats:
cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
1999/5/EEC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con la siguientes
normas:
EN 55022 ( CLASS B ITE ),
SEPTEMBER 1998:
INFORMATION TECHNOLOGY EQUIPMENT
RADIO DISTURBANCE CHARACTERISTICS
LIMITS AND METHODS OF MEASUREMENTS
EN 55024, SEPTEMBER 1998:
AMENDMENT A1, OCTOBER 2001
AMENDMENT A2, JANUARY 2003
INFORMATION TECHNOLOGY EQUIPMENT
IMMUNITY CHARACTERISTICS
LIMITS AND METHODS OF MEASUREMENT
EN 60950-1:2006
INFORMATION
TECHNOLOGY
EQUIPMENT
SAFETY PART 1 : GENERAL REQUIREMENTS
Lippo di Calderara, August 3rd, 2010
Paola Chientaroli
Quality Assurance Manager
-
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement