Product Datasheet
UD info Corp.
Industrial mSATA Drive
MHD-52UN Series
Product DataSheet
UD info CORP.
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
TEL: +886-2-7713-6050 FAX: +886-2-8511-3151
E-mail: sales@UDinfo.com.tw
Product Datasheet
1.
Introduction ............................................................................................... 5
1.1.
General Description ......................................................................................................... 5
1.2.
Block Diagram ................................................................................................................. 5
2.
Product Specifications ............................................................................... 6
3.
Environmental Specifications ..................................................................... 7
3.1.
Environmental Conditions ............................................................................................... 7
3.1.1.
Temperature and Humidity .................................................................................. 7
3.1.2.
Shock.................................................................................................................... 8
3.1.3.
Vibration............................................................................................................... 8
3.1.4.
Drop ..................................................................................................................... 8
3.1.5.
Bending ................................................................................................................ 8
3.1.6.
3.1.7.
4.
5.
3.2.
MTBF ............................................................................................................................... 9
3.3.
Certification ..................................................................................................................... 9
3.4.
Compliance ...................................................................................................................... 9
Electrical Specifications ........................................................................... 10
4.1.
Supply Voltage............................................................................................................... 10
4.2.
Power Consumption ....................................................................................................... 10
Interface .................................................................................................. 11
5.1.
6.
Torque .................................................................................................................. 9
Electrostatic Discharge (ESD) ............................................................................. 9
Pin Assignment and Descriptions .................................................................................. 11
Supported Commands .............................................................................. 13
6.1.
ATA Command List ...................................................................................................... 13
6.2.
Identify Device Data ...................................................................................................... 14
6.3.
Write Protect Function ................................................................................................... 19
6.4.
Quick Erase Function ..................................................................................................... 19
7.
Physical Dimension .................................................................................. 20
8.
Terminology ............................................................................................. 21
9.
Barcode description ................................................................................. 21
10.
Partnumber decoder ................................................................................ 22
UD info CORP. TEL: +886-2-7713-050 FAX: +886-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
2
Product Datasheet
Revision History
Revision
Draft Date
History
Author
1.0
2014/11/11
New release
Golden Lee
1.1
2014/12/10
Modify Quick Erase function
Golden Lee
UD info CORP. TEL: +886-2-7713-050 FAX: +886-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
3
Product Datasheet
Product Overview

Capacity
■
■
■

■
■

■

SATA Revision 3.0
SATA 1.5Gbps, 3Gbps, and 6Gbps
interface
■
■
■
■
■
■

Read: up to 520 MB/s
Write: up to 195 MB/s
■

Active mode: < 2000mW
Idle mode: < 330mW
DEVSLP mode: < 5mW
■
■

DEVSLP Mode (Optional)
DIPM/HIPM Mode
Temperature Range
■
TBW (Terabyte Written)
Static and Dynamic Wear Leveling
Bad Block Management
TRIM
SMART
Over-Provision
Low Power Management
■
Note1
SLC: 3,000,000 hours
MLC: 2,000,000 hours
pSLC: 2,500,000 hours
Advanced Flash Management
■
Flash Type: SLC,MLC and pSLC
Power Consumption
■

■
Performance
■
MTBF
■
Flash Interface
■

SLC: 1GB up to 64GB
MLC: 4GB up to 256GB
pSLC: 2GB up to 128GB
SATA Interface
■


Operation (Standard): 0°C ~ 70°C
Operation (Wide): -40°C ~ 85°C
Storage: -40°C ~ 85°C
Compliant
■
SLC: 3,448TBW for 64GB
■
■
MLC: 635 TBW for 256GB
■
■
pSLC: 3280TBW for 128GB
RoHS
CE & FCC
Notes:
1. Please see Power Consumption” for details.
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
4
Product Datasheet
1. INTRODUCTION
1.1. General Description
UDinfo mSATA delivers all the advantages of flash disk technology with the Serial ATA I/II/III interface and is
fully compliant with the standard mSATA form factor, known as JEDEC MO-300 standard. The module is
designed to operate at a maximum operating frequency of 300MHz with 40MHz external crystal. Its
capacity could provide a wide range up to 256GB. Moreover, it can reach up to 520MB/s read as well as
195MB/s write high performance based on Toshiba NAND flash (with 8MB/32MB SDR enabled and
measured by CrystalDiskMark v3.0). Meanwhile, the power consumption of the mSATA module is much
lower than traditional hard drives.
1.2. Block Diagram
DC-DC
VCC
Vcore
VCC
SATA
Interface
Flash
Controller
Flash memory
Data
Buffer
A+
A-
SATA
PHY
Data
Flash
A
B+
B-
Control signal
DEVSLP
mSATA Block Diagram
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
5
2. PRODUCT SPECIFICATIONS
Product Datasheet
Capacity

■
SLC: From 1GB up to 64GB (support 48-bit addressing mode)
■
MLC: From 4GB up to 256GB (support 48-bit addressing mode)
■
pSLC: From 2GB up to 128GB (support 48-bit addressing mode)
Electrical/Physical Interface

SATA Interface
■

Compliant with SATA Revision 3.0

Compatible with SATA 1.5Gbps, 3Gbps and 6Gbps interface

Support power management

Support expanded register for SATA protocol 48 bits addressing mode

Embedded BIST function for SATA PHY for low cost mass production
Supported NAND Flash

■
Toshiba SLC and MLC, Toggle1.0 and Toggle2.0
■
Supports SLC large block 4K, 8K/page NAND flash
■
Supports MLC large block 16K/page NAND flash
■
Support ONFI 2.3 and ONFI 3.0 interface: 4 channels at maximum
ECC Scheme

■
Up to 72 bits / 1K Byte

UART function

GPIO

Support SMART and TRIM commands

Support Hardware Write Protect function (optional)

Support Hardware Quick Erase function (optional)
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
6
3. ENVIRONMENTAL SPECIFICATIONS
Product Datasheet
3.1. Environmental Conditions
3.1.1. Temperature and Humidity



Temperature:

Storage: -40°C to 85°C

Operational (Standard grade): 0°C to 70°C

Operational (Wide grade): -40°C to 85°C
Humidity:

Standard grade: RH 90% under 40°C (operational)

Wide grade: RH 95% under 55°C (operational)
High Temperature Test Condition
Temperature
Humidity
Test Time
Operation (Standard)
70°C
0% RH
72 hours
Operation (Wide)
85°C
0% RH
72 hours
Storage (Standard)
85°C
0% RH
72 hours
Storage (Wide)
85°C
0% RH
168 hours
Temperature
Humidity
Test Time
Operation (Standard)
0°C
0% RH
72 hours
Operation (Wide)
-40°C
0% RH
72 hours
Storage (Standard)
-40°C
0% RH
72 hours
Storage (Wide)
-40°C
0% RH
168 hours
Temperature
Humidity
Test Time
Operation (Standard)
40°C
93% RH
24 hours
Operation (Wide)
55°C
95% RH
72 hours
Storage (Standard)
40°C
95% RH
72 hours
Storage (Wide)
55°C
95% RH
96 hours
Result: No any abnormality is detected.

Low Temperature Test Condition
Result: No any abnormality is detected.

High Humidity Test Condition
Result: No any abnormality is detected.
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
7
Product Datasheet

Temperature Cycle Test
Temperature
Test Time
0°C
30 min
70°C
30 min
-40°C
30 min
85°C
30 min
-40°C
30 min
85°C
30 min
-40°C
30 min
85°C
30 min
Operation (Standard)
Operation (Wide)
Storage (Standard)
Storage (Wide)
Cycle
10 cycles
20 cycles
10 cycles
50 cycles
Result: No any abnormality is detected.
3.1.2. Shock

Shock Specification
Acceleration Force
Half Sin Pulse Duration
1500G
0.5ms
Operational
Result: No any abnormality is detected when power on.
3.1.3. Vibration

Vibration Specification
Condition
Frequency/Displacement
Frequency/Acceleration
20Hz~80Hz/1.52mm
80Hz~2000Hz/20G
Operational
Vibration Orientation
X, Y, Z axis/60 min for each
Result: No any abnormality is detected when power on.
3.1.4. Drop

Drop Specification
Height of Drop
Non-operational
80cm free fall
Number of Drop
6 face of each unit, 2
times
Result: No any abnormality is detected when power on.
3.1.5. Bending

Bending Specification
Non-operational
Force
Action
≥ 50N
Hold 1min/5times
Result: No any abnormality is detected when power on.
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
8
Product Datasheet
3.1.6. Torque
Torque Specification

Non-operational
Force
Action
0.5N-m or 5 deg
Hold 1min/5times
Result: No any abnormality is detected when power on.
3.1.7. Electrostatic Discharge (ESD)
Contact ESD Specification

Device
mSATA
Capacity
Temperature
64GB
128GB
Relative Humidity
+/- 4KV
Result
Device functions are affected, but
24.0°C
49% (RH)
EUT will be back to its normal or
PASS
operational state automatically.
3.2. MTBF
MTBF, an acronym for Mean Time between Failures, is a measure of a device’s reliability. Its value
represents the average time between a repair and the next failure. The measure is typically in units of hours.
The higher the MTBF value, the higher the reliability of the device. The predicted result of UDinfo’s mSATA is
up to 3,000,000 hours.
3.3. Certification

RoHS

CE / FCC
3.4. Compliance

SATA III (SATA Rev. 3.0)

Up to ATA/ATAPI-8 (Including S.M.A.R.T)
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
9
Product Datasheet
4. ELECTRICAL SPECIFICATIONS
4.1. Supply Voltage
Parameter
Rating
Operating Voltage
3.3V
4.2. Power Consumption
Current
Read
Write
Partial
Slumber
Idle
DEVSLP
SLC (max.)
1460
1480
80
30
280
4.9
MLC (max.)
1960
1730
55
35
285
4.9
pSLC (max.)
1960
1720
90
75
325
4.9
Unit: mW
NOTES:
1.
It’s average value of power consumption based on 100% conversion efficiency.
2.
The measured power voltage is 3.3V.
3.
Samples were built using Toshiba NAND flash and measured under normal temperature.
4.
Sequential R/W is measured while testing 4000MB sequential R/W 5 times by CyrstalDiskMark. DEVSLP is
measured while entering device sleep mode for 5 minutes.
5.
Power Consumption may differ according to flash configuration, SDR configuration, or platform.
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
10
Product Datasheet
5. INTERFACE
5.1. Pin Assignment and Descriptions
Pin #
mSATA Pin
Description
1
NC
No Connect
2
+3.3V
3.3V Source
3
NC
No Connect
4
DGND
Digital GND
5
NC
No Connect
6
NC
No Connect
7
NC
No Connect
8
NC
No Connect
9
DGND
Digital GND
10
NC
No Connect
11
NC
No Connect
12
NC
No Connect
13
NC
No Connect
14
NC
No Connect
15
DGND
Digital GND
16
NC
No Connect
17
NC
18
DGND
19
NC
20
NC
No Connect
21
SATA GND
SATA Ground Return Pin
22
NC
No Connect
23
TXP (out)
Host Receiver Differential Signal Pair
24
+3.3V
3.3V Source
25
TXN (out)
Host Receiver Differential Signal Pair
26
SATA GND
SATA Ground Return Pin
27
SATA GND
SATA Ground Return Pin
28
NC
No Connect
29
SATA GND
SATA Ground Return Pin
30
NC
No Connect
No Connect
Reserve for Quick Erase (Active low)
Digital GND
No Connect
Reserve for Write Protect (Active high)
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
11
Product Datasheet
Pin #
mSATA Pin
Description
31
RXN (in)
Host Transmitter Differential Signal Pair
32
NC
No Connect
33
RXP (in)
Host Transmitter Differential Signal Pair
34
DGND
Digital GND
35
SATA GND
SATA Ground Return Pin
36
NC
No Connect
37
SATA GND
SATA Ground Return Pin
38
NC
No Connect
39
+3.3V
3.3V Source
40
DGND
Digital GND
41
+3.3V
3.3V Source
42
NC
No Connect
43
NC
No Connect
44
DEVSLP
Enter/Exit DevSleep
45
NC
Reserved pin
46
NC
No Connect
47
NC
Reserved pin
48
NC
No Connect
49
DAS
Device Activity Signal
50
DGND
Digital GND
51
GND
Default connect to GND
52
+3.3V
3.3V Source
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
12
Product Datasheet
6. SUPPORTED COMMANDS
6.1. ATA Command List
Code
Description
Code
Description
00h
NOP
97h
IDLE
06h
Data Set Management
98h
CHECK POWER MODE
Recalibrate
99h
SLEEP
20h
Read Sectors
B0h
SMART
21h
Read Sectors without Retry
B1h
DEVICE CONFIGURATION
24h
Read Sectors EXT
C4h
Read Multiple
25h
Read DMA EXT
C5h
Write Multiple
27h
Read Native Max Address EXT
C6h
Set Multiple Mode
29h
Read Multiple EXT
C8h
Read DMA
2Fh
Read Log EXT
C9h
Read DMA without Retry
30h
Write Sectors
CAh
Write DMA
31h
Write Sectors without Retry
CBh
Write DMA without Retry
34h
Write Sectors EXT
CEh
Write Multiple FUA EXT
35h
Write DMA EXT
E0h
Standby Immediate
37h
Set Native Max Address EXT
E1h
Idle Immediate
38h
CFA WRITE SECTORS WITHOUT ERASE
E2h
Standby
39h
Write Multiple EXT
E3h
Idle
3Dh
Write DMA FUA EXT
E4h
Read Buffer
3Fh
Write Long EXT
E5h
Check Power Mode
40h
Read Verify Sectors
E6h
Sleep
41h
Read Verify Sectors without Retry
E7h
Flush Cache
42h
Read Verify Sectors EXT
E8h
Write Buffer
45h
WRITE UNCORRECTABLE EXT
EAh
Flush Cache EXT
60h
Read FPDMA Queued
ECh
Identify Device
61h
Write FPDMA Queued
EFh
Set Features
Seek
F1h
Security Set Password
90h
Execute Device Diagnostic
F2h
Security Unlock
91h
Initialize Device Parameters
F3h
Security Erase Prepare
92h
Download Microcode
F4h
Security Erase Unit
93h
DOWNLOAD MICROCODE DMA
F5h
Security Freeze Lock
94h
STANDBY IMMEDIATE
F6h
Security Disable Password
95h
IDLE IMMEDIATE
F8h
Read Native Max Address
96h
STANDBY
F9h
Set Max Address
10h-1Fh
70h-7Fh
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
13
Product Datasheet
6.2. Identify Device Data
The following table details the sector data returned by the IDENTIFY DEVICE command.
F: Fixed
Word
V: Variable
Default Value
Description
X: Both
0
F
0040h
General configuration bit-significant information
1
X
*1
2
V
C837h
Specific configuration
3
X
0010h
Obsolete – Number of logical heads (16)
4-5
X
00000000h
6
X
003Fh
Obsolete – Number of logical cylinders
Retired
Obsolete – Number of logical sectors per logical track
(63)
7-8
V
00000000h
Reserved for assignment by the Compact Flash
Association
9
X
0000h
Retired
10-19
F
Varies
Serial number (20 ASCII characters)
20-21
X
0000h
Retired
22
X
0000h
Obsolete
23-26
F
Varies
Firmware revision (8 ASCII characters)
27-46
F
Varies
Model number (xxxxxxxx)
47
F
8010h
7:0- Maximum number of sectors transferred per
interrupt on MULTIPLE commands
48
F
4000h
Trusted Computing feature set options(not support)
49
F
2F00h
Capabilities
50
F
4000h
Capabilities
51-52
X
000000000h
53
F
0007h
54
X
*1
55
X
0010h
Obsolete – Number of logical heads (16)
56
X
003Fh
Obsolete – Number of logical sectors per track (63)
57-58
X
*2
59
F
0110h
Obsolete
Words 88 and 70:64 valid
Obsolete – Number of logical cylinders
Obsolete – Current capacity in sectors
Number of sectors transferred per interrupt on
MULTIPLE commands
60-61
F
*3
62
X
0000h
Obsolete
63
F
0407h
Multi-word DMA modes supported/selected
Maximum number of sector ( 28bit LBA mode)
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
14
Product Datasheet
F: Fixed
Word
V: Variable
Default Value
Description
X: Both
64
F
0003h
PIO modes supported
65
F
0078h
Minimum Multiword DMA transfer cycle time per
word
66
F
0078h
Manufacturer’s recommended Multiword DMA
transfer cycle time
67
F
0078h
Minimum PIO transfer cycle time without flow control
68
F
0078h
Minimum PIO transfer cycle time with IORDY flow
control
69
F
0100h
Additional Supported (support download microcode
DMA)
70
F
0000h
71-74
F
000000000000000
Reserved
Reserved for the IDENTIFY PACKET DEVICE command
0h
75
F
001Fh
Queue depth
76
F
670eh
Serial SATA capabilities
77
F
0084h
Serial ATA Additional Capabilities
78
F
014Ch
Serial ATA features supported
79
V
0040h
Serial ATA features enabled
80
F
07F8h
Major Version Number
81
F
0000h
Minor Version Number
82
F
346bh
Command set supported
83
F
7d09h
Command set supported
84
F
6063h
Command set/feature supported extension
85
V
3469h
Command set/feature enabled
86
V
bc01h
Command set/feature enabled
87
V
6063h
Command set/feature default
88
V
00XXh
Ultra DMA Modes
89
F
0001h
Time required for security erase unit completion
90
F
001Eh
Time required for Enhanced security erase completion
91
V
0000h
Current advanced power management value
92
V
FFFEh
Master Password Revision Code
93
F
0000h
Hardware reset result. The contents of the bits (12:0)
of this word can be changed only during the execution
of hardware reset.
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
15
Product Datasheet
F: Fixed
Word
V: Variable
Default Value
Description
X: Both
94
V
0000h
Vendor’s recommended and actual acoustic
management value
95
F
0000h
Stream Minimum Request Size
96
V
0000h
Streaming Transfer Time – DMA
97
V
0000h
Streaming Access Latency – DMA and PIO
98-99
F
0000h
Streaming Performance Granularity
100-103
V
*4
104
V
0000h
Streaming Transfer Time – PIO
105
F
0008h
Maximum number of 512-byte blocks per DATA SET
Maximum user LBA for 48 bit Address feature set
MANAGEMENT command
106
F
4000h
Physical sector size/Logical sector size
107
F
0000h
Inter-seek delay for ISO-7779 acoustic testing in
microseconds
108-111
F
000000000000000
Unique ID
0h
112-115
F
000000000000000
Reserved
0h
116
V
0000h
Reserved
117-118
F
00000000h
119
F
4014h
Supported settings
120
F
4014h
Command set/Feature Enabled/Supported
121-126
F
0h
Reserved
127
F
0h
Removable Media Status Notification feature set
Words per logical Sector
support
128
V
0021h
Security status
129-140
X
0h
Vendor specific
141
X
0001h
Vendor specific
142-159
X
0h
Vendor specific
160
F
0h
Compact Flash Association (CFA) power mode 1
161-167
X
0h
Reserved for assignment by the CFA
168
F
3h
2.5 inch
Device Nominal Form Factor
4h
1.8 inch
5h
Less than 1.8
inch
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
16
Product Datasheet
F: Fixed
Word
V: Variable
Default Value
Description
X: Both
169
F
0001h
170-173
F
0h
Additional Product Identifier
0h
Reserve
174-175
DATA SET MANAGEMENT command is supported
176-205
V
0h
Current media serial number
206
F
0h
SCT Command Transport
207-208
F
0h
Reserved
209
F
4000h
Alignment of logical blocks within a physical block
210-211
V
0000h
Write-Read-Verify Sector Count Mode 3 (not support)
212-213
F
0000h
Write-Read-Verify Sector Count Mode 2 (not support)
0000h
NV Cache relate (not support)
Non-rotating media device
214-216
217
F
0001h
218
F
0h
Reserved
219
F
0h
NV Cache relate (not support)
220
V
0h
Write read verify feature set current mode
0h
Reserved
221
222
F
107Fh
Transport major version number
223
F
0h
Transport minor version number
224-229
0h
reserved
230-233
0h
Extend number of user addressable sectors
234
0001h
Minimum number of 512-byte data blocks per
DOWNLOAD MICROCODE command for mode 03h
235
0080h
Maximum number of 512-byte data blocks per
DOWNLOAD MICROCODE command for mode 03h
236-254
F
0h
255
X
XXA5h
Reserved
Integrity word (Checksum and Signature)
XX is variable
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
17
Product Datasheet

List of Device Identification for Each Capacity
Capacity
*1
*2
*3
*4
(GB)
(Word 1/Word 54)
(Word 57–58)
(Word 60–61)
(Word 100–103)
1
7A7h
1E2190h
1E2190h
1E2190h
2
F39h
3BF070h
3BF070h
3BF070h
4
1E5Dh
778E30h
778E30h
778E30h
8
3CA5h
EEC9B0h
EEC9B0h
EEC9B0h
16
3FFFh
FBFC10h
1DD40B0h
1DD40B0h
32
3FFFh
FBFC10h
3BA2EB0h
3BA2EB0h
64
3FFFh
FBFC10h
7740AB0h
7740AB0h
128
3FFFh
FBFC10h
EE7C2B0h
EE7C2B0h
256
3FFFh
FBFC10h
FFFFFFFh
1DCF32B0h
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
18
Product Datasheet
6.3. Write Protect Function
UDinfo’s MHD-52UD mSATA supports hardware write protect function. It contains a slide switch. By setting
the switch can enable or disable the Write protection function. This switch is used to set the device as a
write protection device after power up. When the switch is placed at Write Protect side, the data can’t be
written to the Flash Module. The module is then set as read only. If the switch is placed to Normal side, the
data can be written or be read as usual.
Note: this function can be control by host through the mSATA interface Pin 19. Please reference the Pin
Description of chapter 5.
6.4. Quick Erase Function
Hardware erase is a special design-in feature and the technology which provides a highly comprehensive
sanitization method. This function should be triggered by jump or push- button. There can be two results
after hardware erase and the result should be pre-selected upon request. The erase procedure will be
totally completed when power re-plug-in.
Note: this function can be control by host through the mSATA interface Pin 17. Please reference the Pin
Description of chapter 5.
Type 1:
Erase all operation blocks.
It terminates all the data in the drive, even user data, firmware and the management table. The drive
would be unable to perform its function anymore after Hardware erase.
Type2:
Erase user data only.
Only user data will be erased. Firmware and management table is reserved so the device would be able
to pursue its full functionality again after format. All the settings will return to its default initial status.
Write Protect
Quick Erase
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
19
Product Datasheet
7. PHYSICAL DIMENSION
Dimension: 50.8mm (L) x 29.85mm (W) x 4mm (H)
Max component height is 1.5mm
Max component height is 1.5mm
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
20
Product Datasheet
8. TERMINOLOGY
The following table is to list out the acronyms that have been applied throughout the document.
Term
ATTO
DEVSLP
Definitions
Commercial performance benchmark application
Device Sleep Mode
DIPM
Device initiated power management
HIPM
Host initiated power management
LBA
Logical block addressing
MB
Mega-byte
MTBF
Mean time between failures
NCQ
Native command queue
SATA
Serial advanced technology attachment
SDR
Synchronous dynamic access memory
S.M.A.R.T.
SSD
Self-monitoring, analysis and reporting technology
Solid state disk
9. BARCODE DESCRIPTION
MHD
5 2 U N 2 5 6 G B C 4 U
yymmddXX
Part Number
Manufacturing
Data: YYMMDD Flash Type:
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
21
10.
Product Datasheet
PARTNUMBER DECODER
MHD-52UNX8X9X10X11X12X13X14X15X16X17
X1X2X3
X4X5
X6X7
X8 X9 X10 X11 X12
001GB
MHD
52
UN
002GB
004GB
008GB
016GB
032GB
064GB
128GB
256GB
X13
X14
X15 X16X17
C: SLC Standard (0ºC ~ +70ºC)
I: SLC Industrial (-40ºC ~ +85ºC)
K: MLC Standard (0ºC ~ +70ºC)
M: MLC Industrial (-40ºC ~ +85ºC)
4
U
P: pSLC Standard (0ºC ~ +70ºC)
F: pSLC Industrial (-40ºC ~ +85ºC)
X16X17
Blank: standard
01: Write Protection(WP)
02: Quick Erase Button(QEB)
03: Quick Erase Jumper(QEJ)
04: WP+QEB
05: WP+QEJ
06: Conformal Coating(CC)
07: CC + WP
08: CC + QEB
09: CC + QEJ
10: CC+WP+QEB
11: CC+WP+QEJ
UD info CORP. TEL: +886-2-7713-6050 FAX: +86-2-8511-3151
3F-4, No.8, Ln. 609, Sec. 5, Chongxin Rd., Sanchong Dist., New Taipei City 241, Taiwan (R.O.C.)
22
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising