IP Link® Device Interface
Communication Sheet
smsg_10_6656_3.pke
Revision: 1/17/2014
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Device Specifications:
Device Type:
Manufacturer:
Firmware Version:
Model(s):
Display
Samsung
N/A
ME32C, ME40C, ME46C, ME55C, ME75C
Version History:
Driver
Version
Date
IP Link
Compiler
GC
Version
Notes
3
1/6/2014
1.6.0
3.5.1
Extron Certified version. Tested on ME40C model. Added
commands based on the new protocol manual.
2
12/17/2013
1.6.0
3.5.1
Added model ME75C.
1
7/1/2013
1.6.0
3.5.0
Initial version.
Driver Notes:
 Driver has been optimized for Volume.
 Device ID is set to default of 1.
 Device ID Broadcast does not support status.
If the channel you desire is 12 on an Analog Signal
o Select Analog under Signal Select.
o Select Cable under Tuner Mode.
o Select 1 and 2
o Select Enter.
If the channel you desire is 12.15 on a Digital Signal
o Select Digital under Signal Select.
o Select Air under Tuner Mode
o Select 1 and 2
o Select ‘.’
o Select 1 and 5
o Select Enter
Page 1 of 7
IP Link® Device Interface
Communication Sheet
smsg_10_6656_3.pke
Revision: 1/17/2014
Control Commands & States:
16:9
4:3
Auto Wide
Zoom
Zoom 1
Zoom 2
Just Scan
Wide Zoom
Wide Fit
Custom
Smart View 1
Smart View 2
Audio Mute
On
Off
Auto Image
Execute
Channel TV (Step)
Up
Down
Channel
0 to 9
.
Aspect Ratio
Clear
Enter
Device ID
0 to 99
Broadcast
Executive Mode 1¹
On
Off
Executive Mode 2²
On
Off
Executive Mode 3³
On
Off
Input
PC
DVI
DTV
HDMI 1
HDMI 2
Display Port
MagicInfo Lite
AV
Component
MagicInfo
On Screen Display
On
Off
PIP Input
PC
DVI
DTV
HDMI 1
HDMI 2
Display Port
MagicInfo Lite
AV
Component
MagicInfo
PIP Mode
On
Off
PIP Position
Upper Left
Upper Right
Lower Right
Medium
Small
Wide
Side by Side
Right
Off
Lower Left
PIP Size
Page 2 of 7
IP Link® Device Interface
Communication Sheet
smsg_10_6656_3.pke
Power Control
On
Off
Signal Select
Analog
Digital
Tuner Mode
Air
Cable
Video Wall Mode
Full
Natural
Volume (Discrete)
0 to 100 in steps of 1
¹Mode 1 is Safety Lock
²Mode 2 is Panel Lock
³Mode 3 is All Lock
Page 3 of 7
Revision: 1/17/2014
IP Link® Device Interface
Communication Sheet
smsg_10_6656_3.pke
Revision: 1/17/2014
Status Available:
16:9
4:3
Auto Wide
Zoom
Zoom 1
Zoom 2
Just Scan
Wide Zoom
Wide Fit
Custom
Smart View 1
Smart View 2
Audio Mute
On
Off
Connection Status
Connected
Disconnected
Executive Mode 1
On
Off
Executive Mode 2
On
Off
Executive Mode 3
On
Off
Input
PC
DVI
DTV
HDMI 1
HDMI 2
Display Port
MagicInfo Lite
AV
Component
Aspect Ratio
Status Unavailable
MagicInfo
Major Channel*
Value
Minor Channel*
Value
On Screen Display
On
Off
PIP Input
PC
DVI
DTV
HDMI 1
HDMI 2
Display Port
MagicInfo Lite
AV
Component
MagicInfo
PIP Mode
On
Off
PIP Position
Upper Left
Upper Right
Lower Right
Medium
Small
Wide
Side by Side
Right
Off
Power Control
On
Off
Video Wall Mode
Full
Natural
Lower Left
PIP Size
Page 4 of 7
smsg_10_6656_3.pke
Volume (Discrete)
IP Link® Device Interface
Communication Sheet
0 to 100 in steps of 1
*Major and Minor Channel do not provide real status.
Page 5 of 7
Revision: 1/17/2014
IP Link® Device Interface
Communication Sheet
smsg_10_6656_3.pke
Revision: 1/17/2014
MLC60 Series Supported Commands:
16:9
4:3
Auto Wide
Zoom
Zoom 1
Zoom 2
Just Scan
Wide Zoom
Wide Fit
Custom
Smart View 1
Smart View 2
Audio Mute
On
Off
Auto Image
Execute
Channel TV (Step)
Up
Down
Executive Mode 1
On
Off
Executive Mode 2
On
Off
Executive Mode 3
On
Off
Input
PC
DVI
DTV
HDMI 1
HDMI 2
Display Port
MagicInfo Lite
AV
Component
Aspect Ratio
MagicInfo
On Screen Display
On
Off
PIP Input
PC
DVI
DTV
HDMI 1
HDMI 2
Display Port
MagicInfo Lite
AV
Component
MagicInfo
PIP Mode
On
Off
PIP Position
Upper Left
Upper Right
Lower Right
Medium
Small
Wide
Side by Side
Right
Off
Power Control
On
Off
Video Wall Mode
Full
Natural
Volume (Discrete)
0 to 100 in steps of 1
Lower Left
PIP Size
Page 6 of 7
smsg_10_6656_3.pke
IP Link® Device Interface
Communication Sheet
Revision: 1/17/2014
Cable and Adapter Requirements:
F/F RS232 DB9 Null modem cable
Notes for the Device:
Please contact the manufacturer for enabling serial port.
To enter service menu: Make sure display is Off, and then rapidly press the following keys “Mute, 1, 8, 2, Power”.
After entering service mode go to Control, then Sub Option, and then set the RS-232 Jack and select UART.
Serial communication:
Port Type: RS-232
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection.
General Notes:
Page 7 of 7