The Pfeiffer ACS 2000 is a single-channel controller designed to work with a range of gauges for measuring pressure in vacuum systems. It offers precise pressure readings, set point management for controlling external devices, and RS232 communication capabilities for integration into existing systems. This versatile controller is commonly used in research and development, instrumentation, and various industrial applications.
PDF
Download
Document
Advertisement
Advertisement
Réalization/Publication: Alcatel Vacuum Technology France - User’s Manual - Ed 03 - Date : 09/2010 - Part Number:113161 *113161* ACS 2000 Single-channel Controller User’s Manual Alcatel Vacuum Technology, as part of the Alcatel-Lucent Group, has been supplying vacuum pumps, helium and hydrogen leak detection systems, plasma sensors, vacuum measurement for several years. Thanks to its complete range of products, the company has become an essential player in multiple applications : instrumentation, Research & Development, industry and semiconductors. Alcatel Vacuum Technology has launched Adixen, its new brand name, in recognition of the company’s international standing in vacuum position. With both ISO 9001 and 14001 certifications, the French company is an acknowlegded expert in service and support, and Adixen products have the highest quality and environmental standards. Gb 03420 - Edition 01 - August 2007 With 45 years of experience, AVT today has a worldwide presence, through its international network that includes a whole host of experienced subsidiaries, distributors and agents. The first step was the founding of Alcatel Vacuum Products (Hingham- MA) in the United States, thirty years ago, reinforced today by 2 others US subsidiaries in Fremont (CA) and Tempe (AZ). In Europe, AVTF-France headquarters and its subsidiaries, Alcatel Hochvakuumtechnik (Germany), Alcatel Vacuum Technology UK (Scotland), Alcatel Vacuum Technology Benelux (Netherlands), Alcatel Vacuum Systems (Italy) and more recently Adixen Sensistor AB in Sweden (in 2007) form the foundation for the European partner network. In Asia, our presence started in 1993 with Alcatel Vacuum Technology (Japan), and has been strengthened with Alcatel Vacuum Technology Korea (in 1995), Alcatel Vacuum Technology Taiwan (in 2001), Alcatel Vacuum Technology Singapore, Alcatel Vacuum Technology Shanghai (China) (in 2004) This organization is rounded off by more than 40 representatives based in a variety of continents. Thus, whatever the circumstances, the users of Adixen products can always rely on quick support of our specialists in Vacuum Technology. ACS 2000 Single-channel controller Welcome Dear customer, You have just acquired an Adixen ACS 2000 controller. We thank you for your purchase and are proud to be able to count you among our customers. GB 03432 - Edition 02 - 03 - October 09 Alcatel Vacuum Technology has acquired a wast wealth of experience in the design of controllers over the year. To guarantee optimum performance and full satisfaction in using this equipment, please take the necessary time to become familiar with this manual before carrying out any operation, especially the section covering installation and commissioning, before installing or operating this controller. The ACS 2000 is a single-channel controller designed to work with the following gauges: - PIRANI gauge: AP 2004 - APN 2004 - Combined PIRANI/Cold cathode gauge: ACC 2009 - Combined CRYSTAL/Hot cathode gauge: AHC 2010 - Capacitive gauges: ASD 200X series, ARD 200X series Alcatel Vacuum Technology France - User's Manual ACS 2000 1/2 ACS 2000 Single-channel controller Copyright/Intellectual property: The use of Adixen products are subject to copyright and intellectual property rights in force in any jurisdiction. All rights reserved, including copying this document in whole or any part without prior written authorization from Alcatel Vacuum Technology France. Specifications and information are subject to change without notice by Alcatel Vacuum Technology France. 2/2 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03432 - Edition 03 - October 09 This product meets all the essential requirements contained in European directives and standards, as listed in the Declaration of Conformity shown in Appendix 9 of this manual. These Directives are amended by Directive 93/68/EEC (CE mark). General contents MANUAL REFERENCE: 113161 EDITION : 03 - September 2010 User’s Manual ACS 2000 Controller English original version Chapter A Commissioning - General safety recommendations - Unpacking and storing the controller - Installation - Quick commissioning procedure Chapter B Product description - Overview of the single-channel controller - Navigation controls Chapter C Settings - Overview - Configuring the gauges - Set point management - General settings for the ACS 2000 Chapter D Test mode - Access to test mode - Software version checking - Analog/Digital converter test - Controller display test - Memory tests - Controller interface tests Chapter E RS232 mode - Introduction - List of commands - Detailed description of RS232 command GB 03431 - Edition 02 - September 07 Chapter F Appendices - Appendix 1: Technical characteristics - Appendix 2: Dimensions - Appendix 3: Rack Installation - Appendix 4: Cable and connector details - Appendix 5: Factory settings - Appendix 6: Error messages - Appendix 7: Accessories - Appendix 8: Conversion of measuring units - Appendix 9: Declaration of conformity - Appendix 10: Detailed example of navigation Alcatel Vacuum Technology France - User's Manual ACS 2000 1/1 A Commissioning ACS 2000 User’s Manual Detailed contents General safety recommendations 2/9 Unpacking and storing the controller 5/9 - Unpacking - Storing the controller - Decontamination - Product recycling Installation 6/9 - Assembly, installation - Table mounting - Rack mounting - Power connections Quick commissioning procedure 7/9 GB 03433 - Edition Edition 03 - October 09 - Bringing the ACS 2000 on line - Start-up screen - Measurement screen and display - Warning or error message - Shutting down Alcatel Vacuum Technology France - User's Manual ACS 2000 1/9 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices General safety rules This controller is designed to be completely safe to use. Nonetheless, there are certain risks that cannot be eliminated. Such risks are indicated throughout this manual by the following warning messages: Warning symbols used in this manual This type of warning is used to indicate a potential risk that can cause significant damage to equipment and/or installations if instructions are not followed. This type of warning is used to indicate a potential risk that can cause minor injury if instructions are not followed. This type of warning is used to indicate a potential risk that can cause serious injury or death if instructions are not followed. GB 03433 - Edition 03 - October 09 This type of warning is used to indicate an imminent risk that can cause serious injury or death if instructions are not followed. 2/9 Alcatel Vacuum Technology France - User's Manual ACS 2000 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices General safety rules Safety instructions for the installation Before switching on the power to this controller, the user must be familiar with this manual and must follow the safety instructions herein. • The Controllers must be connected to an electrical installation fitted with a type TT earthed socket in compliance with ruling 88-1056 of 14th November, 1988 (for French regulation). • Our products are designed to meet all CEE regulations in effect. Any modifications by the user are liable to break compliance with regulations and jeopardise the EMC (Electromagnetic Compatibility) performance and product safety. The manufacturer renounces all responsibility for the consequences of any such intervention. The EMC performance of this product is obtained only if the installation is carried out in compliance with the applicable EMC rules. In particular, in environments liable to emit strong EM disturbances, you must - use shielded cables and connections for the interfaces - protect the power line by a shielding from the power source to within 3 metres of the power input to the product. GB 03433 - Edition Edition 03 - October 09 The enclosure is designed to ensure normal safety conditions in its normal operating environment (in a rack). When used on a table, or when handling the enclosure make sure no objects are introduced into the ventilation holes and that these holes are not blocked. When switching off equipment containing condensers charged at more than 60 VDC or 25 VAC, take all necessary precautions to protect against contact with the pins on the connectors (single phase motors, equipment with mains filter, frequency inverter, monitor, etc.) Alcatel Vacuum Technology France - User's Manual ACS 2000 3/9 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices General safety rules This product’s safety and performance can not be guaranteed unless it is used in compliance with this manual. This symbol on the controller body indicates that certain internal components are under voltage and can cause electric shock if touched. This symbol recommends that the controller be disconnected from the mains before any work is carried out on it or that the circuit breaker be correctly identified and locked. This symbol on the controller body indicates a potential risk that could cause significant damage to the equipment and/or installations if instructions are not followed. Responsibility and guarantee 4/9 Jobs described in this document may be carried out only by staff possessing the appropriate technical training and necessary experience or having been trained to this end by the product owner. The manufacturer’s responsibility is lifted and the guarantee voided if the owner or a third party • fails to observe the instructions in this document, • uses this product in a way that is not consistent with the manufacturer’s intended use, • modifies this product in any way whatsoever, • uses the product with accessories not listed in the product documentation. Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03433 - Edition 03 - October 09 Qualification of personnel A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Unpacking Unpacking and storing the controller Take care in unpacking the equipment and keep its all of the packaging. Make sure there is no shipping damage. If any such damage is noted, take the necessary measures with the carrier and notify the manufacturer if necessary. In all cases we advise you to keep the packaging (recyclable material) in case the controller needs to be shipped again, or must be stored for a long time. This product was manufactured in a clean environment and packaged carefully to maintain this cleanliness, we advise you not to unpack the controller until it is at its place of installation. Remove the equipment manually from its package (weight 1.3 kg). The electrical cables (power cable and gauge connection cables) are shipped in a separate package (see appendix 7). Storing the controller The controller can be stored in its original packaging at temperature of –20°C to +60°C. GB 03433 - Edition Edition 03 - October 09 Decontamination and product recycling In compliance with Directive 2002/96/CE concerning the handling of electrical and electronic equipment waste and Directive 2002/9/CE concerning restrictions on hazardous substances, Adixen products that have reached the end of their service life must be returned to the manufacturer for decontamination and reuse. The manufacturer’s obligation to recover such equipment applies only to complete items of equipment that have been neither modified nor retrofitted and have used only spare parts from Alcatel Vacuum Technology sold by Alcatel Vacuum Technology and including all their assemblies and sub-assemblies. This obligation does not include the cost of transporting the product to a reprocessing centre, nor the cost of the service which will be invoiced on to the customer. For all equipment returned to an Alcatel service center, the safety questionnaire at the end of manual (or available online at www. adixen.com) must be filled in and sent to the service center in advance. Alcatel Vacuum Technology France - User's Manual ACS 2000 5/9 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Assembly, installation Installation The controller can be placed on a table or mounted in a rack. Table mounting Ventilation Locate the appliance in a way that ensures good air circulation and avoids direct exposure to the sun. Rack mounting See appendix 3 Electric shock hazard. Before connecting the gauges, set the power switch to the «0» (off) position. Always connect the gauges before switching on power to the controller. The supply voltage to the unit must be between 100 and 240 VAC. Check the supply voltage and always use adequate cabling. Failure to follow these instructions can lead to electric shock. 6/9 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03433 - Edition 03 - October 09 Controller ventilation Internal components can deteriorate through overheating if there is inadequate ventilation. DO not block the ventilation holes. A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Bringing the ACS2000 on line Quick commissioning procedure 1 - Place the ACS 2000 controller on a table 2 - Connect the vacuum gauge to the connection at the back of the controller. 3 - Connect the mains power cable Products which are not properly connected to ground are a danger to life in the event of failure. The controller frame must be connected to earth and an earth wire is provided for this purposes in the 3-pin power cable (PE). Always connect the power cable to a socket with a ground. GB 03433 - Edition Edition 03 - October 09 4 - Set the power switch to the «1» (ON) position. 2 3 4 1 Alcatel Vacuum Technology France - User's Manual ACS 2000 7/9 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Quick commissioning procedure Start-up screen At the start-up and before displaying the measurement screen, the controller performs: 1 - Display test 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪤㪜㪘㪪 㪝 㪠㪣 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪛㪜㪞㪘㪪 㪟㪭㪄㪛 㪪㪙 㪣 㪪㪧 㩷 㪈 㩷 㪉 㪱㪜㪩㪦 㪞㪘㪪 㪚㪦㪤㪤 㪭 㫆 㫃㫋 㪫 㫆 㫉㫉 㪧㪸 㫄 㪹㪸㫉 㪘㪣㪤 㪣㪦 㪚㪢 2 - Display of the software version Software version number 3 - Detection of the gauge type 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪪㪧 㩷 㪈 㩷 㪉 㪚㪦㪤㪤 Type of gauge Measurement screen and display The measurement is available if: - The gauge is properly connected - The pressure lies within the measuring range of the connected gauge SP 1 2 Exponent mbar Unit Measurement readout E.g., the "AHC" type gauge measures a pressure of 1.2 x 102 mbar. Note 8/9 From the measurement screen, it’s possible to identify what gauge is connected by pressing the button Enter. Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03433 - Edition 03 - October 09 Restores the parameters that were set before power was turned off, or adapts the parameters if the gauge has changed. A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Warning or error messages Quick commissioning procedure The following warning message comes up when no gauge is connected. An error message is displayed when an error is detected at controller start-up - see Appendix 6 for the error message list. Shutting down Switch off the ACS 2000 by setting the power switch to the «O» position (or via the distribution box if rack mounted). GB 03433 - Edition Edition 03 - October 09 Before switching the ACS 2000 on again, wait at least 10 seconds to allow it to reset. Alcatel Vacuum Technology France - User's Manual ACS 2000 9/9 Product description B ACS 2000 User’s Manual Detailed contents Overview of the single-channel controller 2/5 - Controller concept - Rear view of controller - Control panel - Description of display Navigation controls 5/5 GB 03434 - Edition Edition 03 - October 09 - Buttons Alcatel Vacuum Technology France - User's Manual ACS 2000 1/5 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices The ACS 2000 provides power, control, and pressure display for the operation of a gauge. It can be controlled by an operator via the front panel, or externally by a computer via the built-in RS232 link. GB 03434 - Edition Edition 03 - October 09 Controller concept Overview of the controller Technical and dimensional characteristics 2/5 Appendices 1 and 2 Alcatel Vacuum Technology France - User's Manual ACS 2000 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Overview of the controller Rear view of controller Power switch RS232 connector (see Section E and Appendix 4) Connectors for gauges (see appendix 4) Power Connection Power indicator light Remote connector (see appendix 4) Ground connection (if required) Rear face GB 03434 - Edition Edition 03 - October 09 Control panel The ACS 2000 is operated from the front face of the enclosure which includes touch buttons and a display. Display Settings and confirm parameters buttons Navigation, selection and modification buttons Front face Alcatel Vacuum Technology France - User's Manual ACS 2000 3/5 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Description of display Overview of the controller Program in progress Displayed with gauge type Display of set point status 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪤㪜㪘㪪 㪝 㪠㪣 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪛㪜㪞㪘㪪 㪟㪭㪄㪛 㪪㪙 㪣 㪪㪧 㩷 㪈 㩷 㪉 㪱㪜㪩㪦 㪞㪘㪪 㪚㪦㪤㪤 㪭 㫆 㫃㫋 㪫 㫆 㫉㫉 㪧㪸 㫄 㪹㪸㫉 㪘㪣㪤 Unit 㪣㪦 㪚㪢 Activated function(s) (gauge or controller) Measured pressure or No Gauge message (if no gauge) or Error message: (Errxx) or Gauge type (*) = AP 2004 - APN 2004 = ACC 2009 = AHC 2010 = ASD 200X - ARD 200X GB 03434 - Edition Edition 03 - October 09 (*) AP ACC AHC AD 4/5 Alcatel Vacuum Technology France - User's Manual ACS 2000 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Navigation controls You can navigate through the controller settings using the buttons. Only the buttons are described below. Refer to appendix 10 if you would like a detailed example of how to navigate. Buttons Access to SETTING functions. Back to previous menu up to DISPLAY screen. 0,5 s On a SETTING screen: Back to DISPLAY screen. 2s On the measurement screen: Access to TEST MODE. 3s ENTER Validation button On the measurement screen, display gauge type. GB 03434 - Edition Edition 03 - October 09 These buttons are used to navigate the menus, select variables, change the variables. Alcatel Vacuum Technology France - User's Manual ACS 2000 5/5 C Settings ACS 2000 User’s Manual Detailed contents Overview 2/14 - Access to settings - List of available settings Configuring the gauges 4/14 General settings - “Gas” correction factor - Analog gauge output Specific settings - AP 2004 - APN 2004 Pirani gauges - ACC 2009 Combined PIRANI/Cold cathode gauge - AHC 2010 Combined CRYSTAL/Hot cathode gauge - ASD 200X - ARD 200X Capacitive gauges Set point management 9/14 - Display - Adjustment by gauge type General settings for the ACS 2000 10/14 GB 03435 - Edition Edition 03 - October 09 - RS232 parameters - Locking the settings - Settings for measurements - Restoring factory default settings - Available remote Inputs/Outputs Alcatel Vacuum Technology France - User's Manual ACS 2000 1/14 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Overview This mode gives access to the user settable functions for - the gauges (prog 1) - the controller (prog 2). Access to settings On the measurement display screen, press the up the following screen: 㪧㪩㪦㪞㪄㪈 㪪㪧 㩷 㪈 㩷 㪉 , button to bring ENTER Use the button to have access to the available parameters for the connected gauge. or Use the button to scroll to next screen. 㪪㪧 㩷 㪈 㩷 㪉 ENTER Use the button to have access to the ACS 2000 controller parameters. GB 03435 - Edition Edition 03 - October 09 㪧㪩㪦㪞㪄㪉 2/14 Alcatel Vacuum Technology France - User's Manual ACS 2000 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Overview List of available settings Gauge settings Prog1 Set points Gas correction factor ACC 2009 AHC 2010, ASD 200X AP 2004 Combined Combined ARD 200X APN 2004 Pirani/ Cold Crystal/ Capacitive Pirani Cathode Hot Cathode gauge • • • • • • • • • • • • • • • • Degaz function Full scale Hot cathode deactivation function 3 - SP2 H 4 - SP2 L 7 - OFS 8 - FSR 9 - DSBL • 10 - URSP • Digit function (5th digit) GB 03435 - Edition Edition 03 - October 09 2 - SP1 L 6 - DEGS • Switching function (UR control) 1 - SP1 H 5 - GAS • • Off Set function Prog 2 • • • • Menu 16 - DIGT ACS2000 controller Menu • • • • • • • 1. DIGT Digit (2 or 3 digit) Filtering Unit Communication speed (baud) Lock setting Factory default settings RS232 adjustment Alcatel Vacuum Technology France - User's Manual ACS 2000 2. FILT 3. UNIT 4. BAUD 5. PLOC 6. FACT 7. 232C 3/14 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Gas correction factor Configuring the gauges General settings This correction factor corrects the measurements from a gauge for gases other than nitrogen (N2). The correction factor has an influence on - the read out - the switching thresholds of the set points. This function is available for all gauges except capacitive ones. Access to this setting 1 - Access : SET/PROG1/5.GAS 2 - Press the 3- Press 㪧㪩㪦㪞㪄㩷㪈㪉㪊㩷 ENTER ENTER button than set the needed value with the button or . button to confirm. 㪪㪧㩷 㪈 㪉 㫄 㪹㪸㫉 㪞㪘㪪㩷 «GAS» is displayed Analog gauge output 4/14 A 0-10 V analog output is available on the Remote connector. Its value is identical to the analog signal delivered by the gauge. See the user manual supplied with the gauge for the voltage to pressure conversion functions and graphs. See Appendix 4: Wiring up the Remote gauge connector. Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03435 - Edition Edition 03 - October 09 Factory default setting The calibration factor is factory set to a value of 1. A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Pirani gauge (AP 2004 - APN 2004) Configuring the gauges Specific settings No further settings for this gauge. Combined PIRANI/ Cold cathode gauge (ACC 2009) Switching function (UR control). Description This setting allows the set point contacts for this channel to be held open or closed when the gauge indicates “UR” (Under Range = pressure below the gauge’s measuring capabilities). There are several possible causes of this “UR” indication: - the pressure really is low - the cold cathode gauge is not primed - the gauge is faulty. ON setting Choose ON if you consider it abnormal for the gauge to have gone UR. Previously activated set points will then be desactivated (detection of UR status). OFF setting Choose OFF if you consider it normal for the gauge to have gone UR. The set point contacts will then remain unchanged. GB 03435 - Edition Edition 03 - October 09 Access to this setting Access : SET/PROG1/10.URSP Factory default setting The switching function is OFF by default. Alcatel Vacuum Technology France - User's Manual ACS 2000 5/14 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Configuring the gauges Specific settings Combined CRYSTAL/ Hot cathode gauge (AHC 2010) Degassing function 㪧㪩㪦㪞㪄㪈 㪪㪧 㪈 Description Deposits on the electrode system of an AHC 2010 combined CRYSTAL/Hot cathode gauge can effect the measured values or make them unstable. Degassing involves heating the electron collector grid to 70°C by electronic bombardment, thus cleaning the electrode system. Degassing normally lasts 3 minutes but can be interrupted prematurely. The function is permitted for pressures < 5.10-3 mbar (pressure advised < 1.10-5 mbar). Activating the degassing function: –> via the controller 1 - Access : SET/PROG1/6. DEGS 㪉 㪛㪜㪞㪘㪪 ENTER Factory default setting The "DEGAS" function is deactivated by default, i.e., factory set to OFF. Note: if the «DEGAS» function can’t be activated, the «ERR08» message displays. (see Appendix 6 for the error message list). Hot cathode deactivation function 㪧㪩㪦㪞㪄㪈 㪪㪧 㪟㪭㪄㪛㪪㪙㪣 㪈 㪉 Description This function deactivates the hot cathode gauge. Only pressure values measured with the CRYSTAL gauge appear. Activating the HV-DSBL function: –> via the controller 1 - Access : SET/PROG1/9. DSBL ENTER 2 - Press the button , then . HV-DSBL comes up on the screen. –> via the Remote connector (HV-DSBL wiring - see Appendix 4) To reactivate measurement, press «HV-DSBL» again. Factory default setting The "Hot cathode deactivation function" is deactivated by default, i.e., factory set to OFF. 6/14 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03435 - Edition Edition 03 - October 09 2 - Press on the button , then . While degassing is in progress (approx. 3 minutes), - “Degas” is displayed on the measuring screen, - ignore the displayed pressure values which will be wrong during this operation. –> via the Remote connector (DEGAS wiring - see Appendix 4)) Note: degassing is impossible when - degassing has just stopped after 3 minutes - the pressure is greater than 5 x 10-3 mbar - «HV-DSBL» is active. A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Configuring the gauges Specific settings Capacitive gauge (ASD 200X - ARD 200X) Digit function Description This function shows or hides the 5th digit in the displayed pressure. Activing the DIGIT function: - Access: SET/PROG1/16. DIGIT 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 - Press the 㪞㪘㪬㪞㪜 ENTER 㩷 㪪㪧 㩷 㪈 㩷 㪉 㪚㪦㪤㪤 button than on the button or . Factory default setting The switching function deactivated by default and the display set to 4 digits. GB 03435 - Edition Edition 03 - October 09 Zero function Description This function allows you to assign a measured pressure value as a datum point. The values displayed will then be negative when the pressure is less than the “ZERO” value entered. Remark: this is only possible in the voltage range of –0.2V to +0.2V delivered on the gauge’s analog output. Activing the ZERO function: - Access: SET/PROG1/7.OFS 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪪㪧 㩷 㪈 㩷 㪉 㪚㪦㪤㪤 㪱㪜㪩㪦 Zero is displayed Note : if the «ZERO» can’t be set, th «ERR09» message displays on the screen for 2 seconds. (see Appendix 6 for the error message list). Alcatel Vacuum Technology France - User's Manual ACS 2000 7/14 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Decimal point function Configuring the gauges Specific settings Description This function lets you modify the read out of the displayed pressure value by changing the position of the decimal point. The exponent changes to suit. Accessing this function - From the measurement screen: Press on the button to move the decimal point on the left. Press on the button to move the decimal point on the right. P R O G -123 TEST GAUGE SP 1 2 COMM m bar P R O G -123 TEST GAUGE SP 1 2 COMM m bar P R O G -123 TEST GAUGE SP 1 2 COMM m bar P R O G -123 TEST GAUGE SP 1 2 COMM Setting «Full scale» Description This setting specifies the top value in the measuring range depending on the gauge used. 㪧㪩㪦㪞㪄㪈 㪪㪧 㪈 㪉 Adjusting this setting: Access: SET/PROG1/8.FSR - Press on the button or to modify the value. Factory default setting: The «Full scale» value is factory set to the highest possible value (1333 mbar). 8/14 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03435 - Edition Edition 03 - October 09 m bar A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Set point management Setpoint display 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪪㪧 㩷 㪈 㩷 㪉 㪚㪦㪤㪤 Set point 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪪㪧 㩷 㪈 㩷 㪉 㪚㪦㪤㪤 㫄 㪹㪸㫉 㫄 㪹㪸㫉 A black square is displayed when SP1 set point is at the «ON» position. No dot: The set points (SP1, SP2) are at the «OFF» position. Adjustment by gauge type The 2 set points are used to control external devices using the “remote” connector. The outputs on the remote connector depend on the setpoint levels programmed and the pressure signal. Each set point has 2 thresholds: - 1 low threshold: SP-xL - 1 high threshold: SP-xH The setpoint opens as the pressure signal goes below the low threshold and remains open until the pressure signal crosses the high threshold. To avoid malfunctioning of the open/close contact, the high threshold value must be set at least 10% higher than the low point value. SP- H SP- L Time GB 03435 - Edition Edition 03 - October 09 Set Point output Closed Open Closed Open Accessing set point adjustment: Access: SET/PROG1/1.SP 1H SET/PROG1/2.SP 1L Access: SET/PROG1/3.SP 2H SET/PROG1/4.SP 2L Pressure adjustment range for set points and initial setting for each type of gauge Gauge AP 2004 Pirani APN 2004 Pirani AHC 2010 Crystal Hot cathode ACC 2009 Cold cathode ASD 200x Capacitive ARD 200x Capacitive Units max setting Pa 1.00E+5 ≥(SP-H)≥(SP-L)≥ ≥(SP-H)≥(SP-L)≥ min setting Initial setting 5.00E-2 5.00E-2 3.75E-4 3.75E-4 Torr 750 mbar 1000 5.00E-4 5.00E-4 Pa 1.00E+5 5.00E-8 5.00E-8 ≥(SP-H)≥(SP-L)≥ Torr 750 3.75E-10 3.75E-10 mbar 1000 5.00E-10 5.00E-10 Pa 1.00E+5 1.00E-7 1.00E-7 Torr 750 7.50E-10 7.50E-10 mbar 1000 1.00E-9 1.00E-9 Pa FSx100 (FS×100)/1000 (FS×100)/1000 Torr FSx0.75 (FSx0.75)/1000 (FSx0.75)/1000 mbar FS FS/1000 FS/1000 ≥(SP-H)≥(SP-L)≥ ≥(SP-H)≥(SP-L)≥ Alcatel Vacuum Technology France - User's Manual ACS 2000 9/14 A B C D E F General settings for the ACS 2000 controller Commissioning Product description Settings Test mode RS232 mode Appendices RS232 settings Communication speed Description This setting is used to adjust the communication speed of the RS232 serial interface. The speed is expressed in Baud units. Accessing this setting: Access: SET/PROG2/4. BAUD Modification of this setting does not require the controller to be restarted. Factory default setting: The communication speed is factory set to 9600 bauds. RS232 setting Selecting the end of line characters for the RS232 transmission CR (carriage return) = return to start of line only (with a risk of overwriting the previous data). CR LF (carriage return + line Feed) = advance to start of next line (with no chance of overwriting the previously sent data). Accessing this setting Access: SET/PROG2/7. RS232C Locking the settings Description This setting stops anyone modifying the configuration. It is activated when the LOCK setting is ON. “Err05” will appear anytime anyone tries to modify a setting. See appendix 6: error messages). To unlock the settings, set parameter lock to “OFF“ 㪧㪩㪦㪞㪄㩷㪉㩷 㪪㪧㩷 㪈 㪉 㪣㪦㪚㪢㩷 Accessing this setting: Access: SET/PROG2/5. PLOC Modification of this setting does not require the controller to be restarted. Factory default setting By default the controller is not locked: LOCK is factory set to “OFF“. 10/14 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03435 - Edition Edition 03 - October 09 Factory default setting: The controller is factory set to the CR position. A B C D E F General settings for the ACS 2000 controller Commissioning Product description Settings Test mode RS232 mode Appendices Settings for measurements Digit Description This setting lets you chose between 2 or 3 digit display for values. This setting concerns all gauges except the capacitive gauge. Accessing this setting: Access: SET/PROG2/1. DIGIT Changing this setting does not require the ACS2000 controller to be restarted. Factory default setting The pressure display is factory set to 2 digits. Units Description This setting lets you choose between the following units for displaying pressure: - mbar - Torr - Pascal The pressure units are shown in the bottom right of the screen. 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪪㪧 㩷 㪈 㩷 㪉 㪚㪦㪤㪤 GB 03435 - Edition Edition 03 - October 09 㫄 㪹㪸㫉 unit Accessing this setting: Access: SET/PROG2/3. UNIT Changing this setting does not require the ACS2000 controller to be restarted. Factory default setting The default pressure unit is factory set to mbar. Alcatel Vacuum Technology France - User's Manual ACS 2000 11/14 General settings for the ACS 2000 controller Commissioning Product description Settings Test mode RS232 mode Appendices Filtering This function smooths the measurement information with a certain frequency response time: Slow/Normal/Fast. This can help with unstable processes or fluctuating measurement signals. Normal filter Choose the “standard” setting to obtain a good compromise between a fast signal response and a noisy signal, on both the display and the set point functions. p Slow filter Choose “slow” to remove noise from the displayed signal, and to eliminate premature tripping of set points caused by signal noise. The controller will then respond more slowly to variations in the measurement. p Fast filter Choose “fast” if the read out and set points must respond quickly to measurement fluctuations. The controller will then be more sensitive to measurement disturbances. p t t t Access to this setting: Access: SET/PROG2/2. FILT Factory default setting This function is set to “NORM”. 12/14 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03435 - Edition Edition 03 - October 09 A B C D E F A B C D E F General settings for the ACS 2000 controller Commissioning Product description Settings Test mode RS232 mode Appendices Restoring factory settings Description This setting causes the ACS 2000 controller to reset all settings their default values (factory default setting). Accessing this setting: Access: SET/PROG2/6. FACT - Select «ON» and press 㪧㪩㪦㪞㪄㩷㪉㩷 㪪㪧㩷 㪈 ENTER . 㪉 «SET» is flashing during 2 s, the screen the automatically switches to the « 6. FACT » menu Factory default setting See appendix 5. Available Remote Inputs/Output GB 03435 - Edition Edition 03 - October 09 Analog recording output A 0-10 V non configurable analog output is available at the Remote connector (pins 2 & 3). Its value is independent of the type of gauge connected to the channel. The signal can be used by applying the following formula: output (V) = 1/2 (Log Pdisp + 12) or Pdisp = 10(2 x output voltage(V) – 12) (Pdisp : value of displayed pressure) See Appendix 4 for wiring of the Remote connector. A voltage of 10V, 9.5V, or 0.5V is considered an error. See list of error messages in Appendix 6. Alcatel Vacuum Technology France - User's Manual ACS 2000 13/14 A B C D E F General settings for the ACS 2000 controller Commissioning Product description Settings Test mode RS232 mode Appendices Available Remote Inputs/Outputs (continued) Remote control The connected gauge can be controlled from the Remote connector. The criteria controlled depend on the gauge type. Table of remote control functions Gauge Gauge input “function1” Gauge input “function2” Pirani AP 2004 - APN 2004 not used not used CRYSTAL/hot cathode AHC2010 DSBL DEGAS Cold cathode/Pirani ACC2009 not used not used Capacitive ASD200X/ARD200X no used not used GB 03435 - Edition Edition 03 - October 09 See Appendix 4 for wiring of the Remote connector. 14/14 Alcatel Vacuum Technology France - User's Manual ACS 2000 Test mode D ACS 2000 User’s Manual Detailed contents Access to test mode 2/6 Software version checking 2/6 Analog/Digital converter test 3/6 - Gauge input voltage - Gauge identification resistance Controller display test 4/6 Memory test 4/6 - EEPROM test Controller interface tests 5/6 GB 03427 - Edition 02 - September 07 - Verification of recorder output voltage - Input/output relay switching test - Testing the front panel buttons - Testing the RS232 link Alcatel Vacuum Technology France - User's Manual ACS 2000 1/6 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Access to test mode You can access the “test mode” by pressing the least 3 seconds. button for at 3s The “TEST MODE” screen comes up. 㪧㪩㪦㪞 㪫㪜㪪㪫 㪪㪧 㪈 㪉 The controller displays the function 1 of the Test mode: software version checking Use the ENTER buttons to select which test to perform and press the button to confirm your choice (see navigation method). Software version checking Description This test allows to check the built-in software version. Accessing the menu Access: SET/1. PNO P R O G -123 TEST GAUGE SP 1 2 COMM Software version Single-channel controller Leaving this menu Press the 2/6 button to get back to the previous screen. Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03436 - Edition 02 - September 07 ENTER - Press button to confirm. - The controller display the software version. A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Gauge identification resistance Analog/Digital converter test Description Use this test to check the identification resistance from the gauge. Accessing the menu Access: SET/2. ADC 1 ENTER - Press button to confirm. - The controller displays the value of the identification resistance. This value depends on the type of gauge (see appendix 4). Leaving this menu Press the Gauge input voltage button to get back to the previous screen. Description Use this test to check the input voltage at the gauge. Accessing the menu Access: SET/3. ADC 2 ENTER GB 03436 - Edition 02 - September 07 - Press button to confirm. - The controller displays the input voltage for the connected gauge. Leaving this menu Press the button to get back to the previous screen. Alcatel Vacuum Technology France - User's Manual ACS 2000 3/6 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Controller display test Description Use this test to visually check the display quality. The controller perform this test by displaying all digits. Accessing this test Access: SET/4. Display Press ENTER button to confirm. Leaving this test Press the button to get back to the previous screen. Memory test EEPROM test Description Use this test to check: - “Program” memory (EEPROM) ENTER Press to confirm. The program starts up automatically. «PASS» is displayed to indicated the test has been passed. «Err» is displayed to indicate the test has failed. Leaving this test Press the 4/6 button to get back to the previous screen. Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03436 - Edition 02 - September 07 Accessing this test Access: SET/5. EEP A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Controller interface tests Description Use these tests to check - the output voltage of the channel for recording - the communication functions of the input/output relays for the channel. - proper operation of the front panel buttons - the RS232 protocol. Verification of recorder output voltage Accessing this test Access : SET/6. DAC Connect a voltage measuring device to the recorder output. ENTER - Press button to confirm. The voltage displayed is 10.0 (Volts) (max value). - Use the 0.1V). buttons to select a different output voltage (10V to Check that the measured voltage is the same as that displayed on the controller. Leaving this test Press GB 03436 - Edition 02 - September 07 Input/output relay switching test to get back to the previous screen. Accessing this test Access : SET/7.IO The relays can be switched manually, independently of the pressure. It is therefore a good idea to disconnect the cable attached to the Remote connector. As soon as you press the ENTER button, the SP1 relay switches to the “ON” position. Use the buttons to change the output relay states and use an appropriate device to check switching of the relays (ON/OFF). n Leaving this test Press to get back to the previous screen. Alcatel Vacuum Technology France - User's Manual ACS 2000 5/6 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Testing the front panel buttons Controller interface tests Accessing this test Access: SET/8.CTRL - Press ENTER button to confirm. Press the various front panel buttons and check that the corresponding names come up on the screen. Ex: —> Screen display : «UP» Leaving this test To leave this test and get back to the previous screen, press and hold down the Testing the RS232 link button. Use this test to check the data transfer to and from a computer. ENTER - Press button to confirm. This screen displays ‘COMM’ while data being transmitted from the computer to the controller. The transmitted character is resent from the controller to the computer. TEST SP 1 2 COMM Leaving this test Press the 6/6 button to get back to the previous screen. Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03436 - Edition 02 - September 07 Accessing this test Access : SET/9.232C E RS232 mode ACS 2000 User’s Manual Detailed contents Introduction 2/7 - RS232 interface - Location of the RS232 interface - Configuring the RS232 protocol - Symbols used - Transmission syntax List of commands 3/7 - Interpreting replies - List of commands 4/7 GB 03437 - Edition 03 - November 09 Detailed description of RS232 commands Alcatel Vacuum Technology France - User's Manual ACS 2000 1/7 Commissioning Product description Settings Test mode RS232 mode Appendices Introduction RS232 interface The RS232 interface is used to operate the controller from a computer via an RS232 cable link (see appendix 4) Location of the RS232 interface The male sub-D 9 pin connector is located on the rear panel of the controller (see chapter B “Overview of single channel controller”). Configuration of RS232 protocol See the “General settings for the ACS 2000 controller” paragraph in the “Configuration” chapter. Data is transmitted in the following format: - 9600 bauds - 8 data bits - 1 stop bit - no parity bit. Symbols used Transmission syntax The following symbols are used in this chapter: < > Definition [ ] Option The transmission syntax is as follows: The order <STX> <COMMAND> [,PARAMETER1] … [, PARAMETERn] <EOM> Control characters (Start of text always $) Reply Used when parameters are required, see “Detailed description of RS232 commands: Syntax of commands for setting parameters”, pages 4 to 7. <STX> <DATA> <EOM> [LF] Data, see “Detailed description of RS232 commands: Queries”, pages 4 to 7. 2/7 End of message characters (CR: Carriage Return) Added if configured at the controller). Carriage return with line feed (LF) Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03437 - Edition 03 - November 09 A B C D E F A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices List of commands Interpretation of replies Reply Statuts Meaning OK No error data received correctly ERR_00001 Operation error unauthorised request ERR_00010 Command error command wording is incorrect ERR_00100 Parameter error parameter value is incorrect ERR_01000 Transmission error a transmission error has been encountered ERR_10000 Hardware error the controller hardware is faulty List of commands GB 03437 - Edition 03 - November 09 Command Function Query Set Type BAU Set transmission speed Controller CON Request continuous reception of pressure value Pressure CPF Set confirmation of power cut Controller DGS Request degassing function for AHC gauges DGT Set number of digits displayed Channel ERR Status of current errors Controller FDS Disable filament of AHC gauges AHC AHC FLT Set filtering Channel FSR Set full scale for AD gauges Channel GAS Adjust gas correction factor Channel LOC Lock settings Controller OFS Request ‘zero’ function for AD gauges Channel PRD Query pressure value for a channel Pressure SP1 Adjust set point ‘SP1’ Channel SP2 Adjust set point ‘SP2’ Channel SPS Query set points status Channel TAD Test Analogique/Digital converters Test TDI Test display Test TEE Test EEPROM Test TID Query type of gauge connected TIO Test set point relays Test TKY Test panel buttons Test TRS Test RS232 link Test UNI Set pressure measurement units Controller VER Query controller software version Controller Alcatel Vacuum Technology France - User's Manual ACS 2000 Channel 3/7 Detailed description of RS232 commands Commissioning Product description Settings Test mode RS232 mode Appendices BAU Syntax Reply Description Set Command Query A B C D E F $BAU,? $a Sets or quieries RS232 Transmission speed a= transmission speed 0 -> 9600 bauds $BAU,a CON $CON,a - 1 -> 19200 bauds 2 -> 38400 bauds $b,c, Request continuous reception of pressure value a = reception interval 0 -> 100 ms 1-> 1s 2 -> 1min b = status of gauge ( 0 -> OK 1-> Ur 2 -> Or 3 -> Err 03 or Err 04 4 -> not used 5 -> No Gauge 6 -> Id Err 7 -> Err Hi or Err Lo or Err 06 or Err 07 c = measured pressure value for gauges AP, ACC, AHC: x.xxE ± xx for gauge AD: ± x.xxxxE ± xx no gauge: 0.00E+00 Press any button to stop transmission. $CPF,? $a Set confirmation of power cut a= memorise power supply problem 0 -> OFF DGS $CPF,a $OK $DGS,? $a 1 -> ON Request degassing function for AHC gauges a = degassing status for AHC gauge 0 -> OFF DGT 4/7 $DGS,a $OK $DGT,a,? $a $DGT,a $OK 1 -> ON Set number of digits displayed a= number of digits 2 or 3 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03437 - Edition 03 - November 09 CPF Detailed description of RS232 commands Commissioning Product description Settings Test mode RS232 mode Appendices ERR Syntax Reply Description Set Command Query A B C D E F $ERR $ERR_a Status of current errors a= error code meaning 00000 -> no error 00001 -> operation error 00010 -> command error 00100 -> parameter error 01000 -> syntax error 10000 -> hardware error FDS $FDS,? $a Disable AHC filament a = status of disable function 0 -> OFF (not disabled) FLT $FDS,a $OK $FLT,? $a 1 -> ON (disabled) Set filtering a = filter 0 -> SLOW FSR $FLT,a $OK $FSR,? $a $FSR,a, $OK 1-> NORMAL 2 -> FAST Set full scale for AD gauges a = full scale for AD gauge 0 -> 1333 mbar 1 -> 133.3 mbar 2 -> 13.33 mbar 3 -> not used 4 -> 1.333 mbar 5 -> not used GB 03437 - Edition 03 - November 09 6 -> (0.333 mbar) 7 -> not used 8 -> 0.133 mbar GAS LOC OFS $GAS,? $a $GAS,a $OK $LOC,? $a $LOC,a $OK $OFS,? $a $OFS,a $OK Alcatel Vacuum Technology France - User's Manual ACS 2000 Adjust gas correction factor a = adjustment of value to suit gas, from 0.10 to 9.99 Lock settings a= status of settings lock 0 -> OFF Request ‘zero’ function for AD gauges a = zero status of AD gauge 0 -> OFF 5/7 Detailed description of RS232 commands Commissioning Product description Settings Test mode RS232 mode Appendices PRD Syntax Reply Description Set Command Query A B C D E F $PRD $a,b Query pressure value for a channel a= gauge status 0 -> OK 1-> Ur 2 -> Or 3 -> Err 03 or Err 04 4 -> not used 5 -> No Gauge 6 -> Id Err 7 -> Err Hi or Err Lo or Err 06 or Err 07 b = measured pressure value for gauges AP, ACC, AHC: x.xxE ± xx for gauge AD: ± x.xxxxE ± xx no gauge: 0.00E+00 SP1 $SP1,? $a,b Adjust set point ‘SP1’ a = set point low threshold SP1L b = set point high threshold SP1H x.xxE ± xx SP2 $SP1,a,bc $OK $SP2,? $b,c $SP2,a,b $OK SP1H >= SP1L Adjust set point ‘SP2’ a = set point low threshold SP2L B = set point high threshold SP2H x.xxE ± xx SP2H >= SP2L $SPS $a,b Query set points status a = status of set point SP1 c = status of set point SP2 0 -> OFF 1 -> ON TAD $TAD $a,b Test Analogique/Digital converters a = value of analogue signal delivered by the gauge ± xx.xxxV -00.000V if no gauge is connected b = value of the gauge identification resistance xx.xE+3 ohms 00.0E+0 ohms if no gauge is connected TDI $TDI,? $a $TDI,a $OK Test display a= screen test status 0 -> OFF 6/7 1 -> ON Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03437 - Edition 03 - November 09 SPS Detailed description of RS232 commands Commissioning Product description Settings Test mode RS232 mode Appendices TEE Syntax Reply Description Set Command Query A B C D E F $TEE $a Test EEPROM a= result of EEPROM test PASS -> OK ERR_ -> error TID $TID $a Query type of gauge connected a = gauge connected AP, ACC, AHC, AD, or NoGau TIO $TIO,a $TIO,a,b TKY $TKY $OK $OK $a Test set point relays a = state of set point relays 0 -> initial state 1 -> set points and 2 OFF 2 -> set points and 2 ON Test panel buttons a= status of command buttons x*** -> SET button *x** -> ENTER button **x* -> ^ button ***x -> v button 0 for OFF, 1 for ON TRS $TRS $OK UNI $UNI,? $a Test RS232 link End of test when ‘ETX’ ( ‘Ctrl C’ ) is transmitted.. Set pressure measurement units a = pressure measurement units 0 -> Pa GB 03437 - Edition 03 - November 09 1 -> Torr VER $UNI,a $OK $VER $a 2 -> mbar Query controller software version a= software version 1-x.xx Alcatel Vacuum Technology France - User's Manual ACS 2000 7/7 F Appendices ACS 2000 User Manual Detailed contents 2/15 Appendix 2: Dimensions 4/15 Appendix 3: Rack Installation 5/15 Appendix 4: Cable and connector details 6/15 Appendix 5: Factory settings 9/15 Appendix 6: Error messages 10/15 Appendix 7: Accessories 12/15 Appendix 8: Conversion of measuring units 13/15 Appendix 9: Declaration of conformity 14/15 Appendix 10: Detailed example of navigation 15/15 GB 03438 - Edition 03 - October 09 Appendix 1: Technical characteristics Alcatel Vacuum Technology France - User's Manual ACS 2000 1/16 Appendix 1 Technical characteristics Commissioning Product description Settings Test mode RS232 mode Appendices General specifications Environment Gauges connected Sockets Voltage 100 - 240 V AC Frequency 50/60 Hz Power requirement < 50 VA Weight 1.3 kg Overvoltage category II Protection class I Storage temperature -20 ...+60 °C Running temperature +5 ... +50 °C Relative humidity < 70 % Use Inside use only, max altitude 2000 metres Pollution level II Protection IP 30 Number 1 Usable types Pirani: AP 2004 - APN 2004 CRYSTAL/Hot cathode: AHC2010 Pirani / Cold cathode: ACC2009 Capacitive: ASD200X-ARD200X Gauges D-Sub 9P (female) Remote D-Sub 15P (female) RS232 D-Sub 9P (male) Front panel buttons 4 buttons Rear panel connectors see “Overview of multi-channel controller” paragraph in this manual Display Screen LCD Refresh time 100 ms Measurement Measuring range specific to gauge Measurement error amplifier: 0.02 % FS Commands Filter time constant offset : 0.05 % FS slow: t = 750 ms (fq = 0.2 Hz) normal: t = 150 ms (fq = 1 Hz) fast: Gauge power supply Gauge commands t = 20 ms (fq = 8 Hz) Pressure mbar, Pa or Torr Zero function Capacitive gauges only Voltage 24 V DC ± 5 % Max power requirement (per channel) 13 W Current protection 900 mA by resettable fuse Number 2 (on gauge connector) ON/OFF signal ON : +24 V, OFF : 0 V continued on page 3/15 2/16 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03438 - Edition 03 - October 09 A B C D E F A B C D E F Appendix 1 Technical characteristics Commissioning Product description Settings Test mode RS232 mode Appendices Remote control power supply Voltage /Max current 24 V DC ± 5 % ; 1 00 mA (on Remote connector) Current protection 300 mA by resettable fuse Set Point output Number 2 (on REMOTE connector) Type of contact Dry contact Allowable load 125 V AC, 0.3 A / 30 V DC, 1 A Mechanical service life 5 x 107 cycles de commutation Electrical service life 1 x 105 cycles de commutation (à charge maxi) Number 2 (on REMOTE connector) Photocoupler input 24 V DC Number 1 (on REMOTE connector) Voltage range - 0.5…10.5 V Remote control input Analog output Recording output Interface (RS232) Standard Accuracy ± 50 mV (difference from displayed value) Impedance 200 Ω Number 1 (on REMOTE connector) Voltage range 0…10 V Precision ± 20 mV Impedance 200 Ω Standard RS232 (RS232 connector) Protocol 1 start bit, 8 data bits, 1 stop bit, no parity bit RS232 TDX, RXD and GND Speed 9600 / 19200 / 38400 Bauds CE mark Low voltage directive: EN61326 (Class A emission) GB 03438 - Edition 03 - October 09 EMC directive: EN61010-1 Alcatel Vacuum Technology France - User's Manual ACS 2000 3/16 Appendix 2 Dimensions Commissioning Product description Settings Test mode RS232 mode Appendices ) 103 mm (4.05 inch) inch diam 2,65 inch m 84 mm (3.3 inch) 212 .34 m (8 67,5 mm A B C D E F 4 x Ø 3,5 m m 91,4 mm (3.5 9 inch) diam 0,137 inch 106,3 mm (4 Front panel thickness: 2.5 mm 4/16 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03438 - Edition 03 - October 09 .18 inch) A B C D E F Appendix 3 Commissioning Product description Settings Test mode RS232 mode Appendices Rack installation To optimize space the ACS 2000 controller can be rack mounted. In this case, we recommend to use a panel mounted circuit breaker. (3.07 inch) 78 mm 69 mm (2.71 inch) 105 mm (4.13 inch) 91,4 mm (3.59 inch) GB 03438 - Edition 03 - October 09 4 M3 holes Ø 0,137 inch If the controller is rack mounted, the controller temperature will rise and this could cause damage. To avoid this leave 20mm free space around the controller. In addition, a fan must be installed in the rack to avoid the ambient temperature rising above 50°C. Alcatel Vacuum Technology France - User's Manual ACS 2000 5/16 A B C D E F Appendix 4 Commissioning Product description Settings Test mode RS232 mode Appendices Cable and connector details This controller has dry contact outputs, it is the customer’s responsibility to use these outputs in compliance with all appropriate safety standards. This chapter gives details of the specifications for each connector and the various cable connections. Gauge connector and gauge cable Before connecting or disconnecting the gauge cables, always turn the controller power supply off first to avoid causing damage to the equipment. D-sub9P (Female) Gauge cable Gauge cable D-sub9P (Male) 1 6 1 2 3 9 3 9 5 Table of gauge identification resistance values 7 8 8 4 1 6 2 7 8 D-sub9P (Male) 1 6 6 2 7 Gauge Gauge cable D-sub9P (Female) 4 9 3 4 5 5 2 7 3 8 9 4 5 Pin No. Signal name Description 1 Measured signal input (+) Analog signal (+) 0–10 V delivered by the gauge 2 Not used Not used 3 Gauge “function” output “DSBL” function for AHC2010 gauge 4 Power supply output (+) 24V DC (+) for power supply to gauge 5 Identification input Gauge “function 2” output Gauge identification (see table below) “DEGAS” function for AHC2010 gauge 6 Not used Not used 7 Not used Not used 8 Measured signal input (-) Analog signal (-) 0–10 V delivered by the gauge 9 Power supply output 24 V DC (0V) for power supply to gauge Gauge Resistance value Pirani AP 2004 - APN 2004 13 KΩ CRYSTAL/hot cathode AHC2010 4.7 KΩ Cold cathod/Pirani ACC2009 15 KΩ (DC mode) 18 KΩ (Pirani mode) Capacitive ASD200X/ARD200X 6/16 7.5 KΩ Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03438 - Edition 03 - October 09 ACS2000 Gauge connector A B C D E F Appendix 4 Commissioning Product description Settings Test mode RS232 mode Appendices Cable and connector details “Remote” connector ACS2000 “Remote” connector D-sub15P (Female) 1 9 +24VDC PS2911-1(K) 2 10 3 22 kΩ 11 PS2911-1(K) 4 22 kΩ 12 5 13 SP2 14 SP1 15 6 7 GB 03438 - Edition 03 - October 09 8 Pin No. Signal name Description 1 Measured signal output (+) Analog signal (+) 0–10 volts delivered by the gauge 2 Output signal (-) 0V of measured signal and recording signal 3 Recording signal output (+) Analog signal (+) 0–10 volts delivered by the controller 4 Gauge “function 1” (+) input 24 VDC to activate the control 5 Gauge “function 1” (-) input 0 V to deactivate the control 6 Set point (NO) 7 Set point common 8 Set point (NC) 9 24 V DC power supply output (+) 10 24 V DC power supply output (-) 11 Input (+) “function 2” gauge 24 VDC to activate the control 12 Input (–) “function 2” gauge 0 V to deactivate the control 13 Set point 14 Set point 2 common 15 Set point 2 (NC) Set point dry contact 24 VDC power supply, max 100 mA 2 (NO) Set point 2 dry contact NO : Normally open NC: Normally closed The 24 V DC power supply output is limited to 100 mA. Moreover, it is not isolated from the internal circuit. When the power supply source for the controller is used for the “Remote” or “Set-Point” control, isolation of the photocoupler and relays is no longer guaranteed. To guarantee complete isolation, therefore, use an external power supply. Before connecting or disconnecting the «Remote» cable, always turn the controller power supply off first to avoid causing damage to the equipment. Alcatel Vacuum Technology France - User's Manual ACS 2000 7/16 A B C D E F Appendix 4 Commissioning Product description Settings Test mode RS232 mode Appendices Cable and connector details Remote connector (continued) Table of Remote control functions Gauge Gauge “function 1” input Gauge “function 2” input Pirani AP 2004 - APN 2004 not used not used CRYSTAL/hot cathode AHC2010 DSBL DEGAS Cold cathode/Pirani ACC2009 not used not used Capacitive ASD200X/ARD200X not used not used In compliance with electromagnetic compatibility standards, use shielded cables for connecting the interfaces. Connect the screening to the chassis earth of the other equipment. Without this, “noise” can be generated which can cause damage to equipment. Comply with the cut off rating for the set point outputs: 125 V AC - 0.3 A or 30 V DC - 1 A. Overvoltages and overcurrents can cause internal electrical damage. ACS2000 RS232 connector D-sub9P (Male) RS232 cable D-sub9P (Female) D-sub9P to PC Pin No. Signal name Description 2 RXD Data reception 3 TXD Data transmission 5 GND Chassis earth If the pin number is not described, it is because it is not used. The RS232 specifications are described in chapter E “RS232 Mode”. 8/16 Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03438 - Edition 03 - October 09 Description and connection of RS232 cable A B C D E F Appendix 5 Factory settings Commissioning Product description Settings Test mode RS232 mode Appendices The values indicated in the table below correspond to factory default settings and can be restored at any time. You can use the «User value» column to note your own specific settings. Default value User value Under-Range control OFF Gas setting 1 Filter setting NORM Full scale setting 1333 mbar Digit setting 2 digit Unit setting mbar Baud rate setting 9600 bps Parameter lock setting OFF RS232 setting CR Set-Point see “Settings by gauge type” table Chapter C GB 03438 - Edition 03 - October 09 Setting Alcatel Vacuum Technology France - User's Manual ACS 2000 9/16 A B C D E F Appendix 6 Error messages Commissioning Product description Settings Test mode RS232 mode Appendices Fault Controller Gauge Power LED & display Definition Possible fault Led OFF No display Power supply board Led ON No display Display or display control Contact customer Service for repair Eprom fault Channel control board 1- Press ENTER for 3 seconds «Setting» appears in flashing then , «SET» is displayed. Switch controller off, then switch on 2- Contact customer Service for repair Button activation «Err Id» Running Correct «Err Id» A/D CPU converter fault -Measurement stopped- Main board P Q 1- Check power supply 2- Contact customer Service for repair R Err 01 Err 02 display 2 seconds S Err 03 Action 1- Switch controller off then switch on 2- Contact customer Service for repair T Err 04 A/D converter fault -Measurement stopped- Channel control board 1- Switch controller off then switch on Err 05 display 2 seconds Modification of a parameter «PLOC» function (ON) running Deactivate the function «PLOC» (OFF) Err 06 Gauge fault: Eprom or converter A/D -Measurement stopped- Gauge error See Gauges: Fault catalog Err 07 AHC gauge fault: Filament B-A or electronic -Measurement stopped- Gauge error See Gauges: Fault catalog Err 08 display 2 seconds Starting of the AHC “Degas” function -Function not started- Conditions required not present Check the required conditions Err 09 display 2 seconds Starting of the A/D “zero” function -Function not started- Conditions required not present Check the required conditions Err Hi Gauge fault: signal 0-10V too high -Measurement stopped- Gauge error See Gauges: Fault catalog Or Pressure over the maximum readable pressure of the gauge (Over range) Gauge message See Gauges: Fault catalog Ur Pressure below the maximum readable pressure of the gauge (Under range) Gauge message See gauges: Catalog of faults E F A B D Led ON 10/16 Led OFF Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03438 - Edition 03 - October 09 2- Contact customer Service for repair A B C D E F Appendix 6 Error messages Commissioning Product description Settings Test mode RS232 mode Appendices Fault Controller Power LED & display Definition Possible fault Action Err Lo «Gauge fault: signal 0-10V too low -Measurement stopped- Gauge error See Gauges: Fault catalog Err Id Identification error of the gauge The gauge is not recognized Check the gauge Check the cable No gauge connected No gauge connected Check the gauge Check the cable Gauge G No GAUGE Led OFF GB 03438 - Edition 03 - October 09 Led ON Alcatel Vacuum Technology France - User's Manual ACS 2000 11/16 12/16 (green) (green) ON - O - I Light indicators : - (red) V < 0,2 V Alcatel Vacuum Technology France - User's Manual ACS 2000 - - Flashing - V < -0,5 V (red) (red) V < -0,2 V - - (red) 0,1 ≤ T < 0,3 V (red) V < 0,1 V - - (red) 0,2 ≤ V < 10,5 or (green) Voltage ≥10,5 (red) - ASD 200X ARD 200X (red) 0,3 ≤ V < 0,5 V (green) 0,5 ≤ V < 0,774 V - GB 03438 - Edition 03 - October 09 OFF - (red) V < 0,2 V - (green) 0,774 ≤ V<10,061 V or 10,061 ≤ V < 10,3 V (green) (red) V ≥ 10,3 V AHC 2010 unpredictable message -30.67 Err Lo Err 07 Err 06 Ur 09677 -20.67 ASD-ARD AP/APN-ACC et AHC 1.2 +2 Or Err Hi Controller message electronic «zéro» drift or contaminated electronic B-A broken filament or contaminated electronic ASD-ARD (red) : pressure over the full scale range or temperature out range ASD-ARD (green): if value measurement is not correct = gauge not «zeroed» or «zero» drift or contamination AP/APN, ACC, AHC: if correct ATM/ VAC adjustment is not possible or in case of erratic measurement = Sensor contaminated AP/APN, ACC: broken filament of Pirani AHC: crystal sensor contaminated or defect Possible defect replace the gauge 1- «zéro» adjustment 2- replacement of the gauge replace electronic 1- check B-A filament 2- run «degas» function 3- replace sensor head replace electronic ASD-ARD (green): «zéro» adjustment ASD-ARD (red): none 2- replace sensor head 1- AP/APN, ACC, AHC: check sensor head AHC: start «degas» 2- replace sensor head 1- AP/APN, ACC: check Pirani filament AHC: check crystal sensor Action Commissioning Product description Settings Test mode RS232 mode Appendices H G - E F (red) 0,2 ≤ V < 0,5 V (red) 0,2 ≤ V < 0,5 V D 1,8 ≤ V < 8,645 V (green) 0,5 ≤ V < 2,199 V 2,199 ≤ V < 8,582 V 8,645 ≤ V < 9,5 V (green) (green) 8,582 ≤ V < 9,5 V (red) V ≥ 9,5 V ACC 2009 (red) V ≥ 9,5 V AP/APN 2004 Signalisation des jauges : Led Power & Voltage (V) (green) 0,5 ≤ V< 2,199 V C B A Fault Gauges: Fault catalog A B C D E F Appendix 6 Error messages A B C D E F Appendix 7 Accessories Commissioning Product description Settings Test mode RS232 mode Appendices Power sockets and cables 1a 1b 1c Item Description P.N 1a mains cable - Europe - 2m 103566 1b mains cable - US+Japan - 2m 103567 1c mains cable - UK - 2m 104411 1d mains cable - Switzerland - 2m 103718 1e mains cable - Italy - 2 m 104758 1d 1e GB 03438 - Edition 03 - October 09 Gauge cables Adapter kit series 1000/ series 2000 measuring range Alcatel Vacuum Technology France - User's Manual ACS 2000 Length P.N 5m 112752 10 m 112753 20 m 112754 Description P.N Gauge adapter 113152 Controller adapter 113153 13/16 Appendix 8 Conversion of measuring units Commissioning Product description Settings Test mode RS232 mode Appendices Weight kg oz 35.274 kg 1 2.205 lb 0.454 1 31.081x10-3 16 slug 14.594 32,174 1 514.785 oz 28.349x10-3 62.5x10-3 1.943x10-3 1 N/m2, Pa bar mbar Torr at N/m2, Pa 1 10x10-6 10x10-3 7.5x10-3 9.869x10-6 bar 100x103 1 103 750.062 0.987 mbar 100 10-3 1 750.062x10-3 0.987x10-3 Torr 133.322 1.333x10-3 1.333 1 1.316x10-3 at 101.325x103 1.013 1.013x103 760 1 mbar Pascal Torr mmH2O 14.504x10-3 psi mbar 1 100 750.062x10-3 10.2 Pascal 10x10-3 1 7.5x10-3 0.102 0.145x10-3 Torr 1,333 133,322 1 13.595 19.337x10-3 mmH2O 9.81x10-2 9.81 7.356x10-2 1 1.422x10-3 68.948 6.895x103 51.715 703 1 psi Length mm m inch ft mm 1 10-3 39.37x10-3 3.281x10-3 m 103 1 39.37 3.281 inch 25.4 25.4x10-3 1 8.333x10-2 ft 304.8 0.305 12 1 Temperature Kelvin (K) Celsius (°C) Fahrenheit (°F) Kelvin (K) 1 °C+273,15 (°F+459,67)x5/9 Celsius (°C) K-273,15 1 5/9x°F-17,778 9/5x(°C+17,778) 1 Fahrenheit (°F) 9/5xK-459,67 14/16 slug 68.522x10-3 Pressure Vacuum technique pressure units lb Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03438 - Edition 03 - October 09 A B C D E F Commissioning Product description Settings Test mode RS232 mode Appendices Appendix 9 Declaration of conformity GB 03438 - Edition 03 - October 09 A B C D E F Alcatel Vacuum Technology France - User's Manual ACS 2000 15/16 A B C D E F Appendix 10 Detailed example of navigation Commissioning Product description Settings Test mode RS232 mode Appendices 1 (Adjusting a set point) Change to settings mode 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪪㪧 㩷 㪈 㩷 㪉 2 Program choice (1) and confirm (2) 㪧㪩㪦㪞㪄㪈 㪚㪦㪤㪤 Function choice (1) and confirm (2) 3 㪪㪧 㩷 㪈 㩷 㪉 㪧㪩㪦㪞㪄㪈 㪪㪧 㪈 㪉 㫄 㪹㪸㫉 ENTRER ENTRER ENTRER 2 4 Change value of setting (1), and confirm (2). 㪧 㪩 㪦 㪞 㪄㪈㪉㪊 㪫㪜㪪㪫 㪞㪘㪬㪞㪜 㩷 㪪㪧 㩷 㪈 㩷 㪉 1 Leave function 5 㪧㪩㪦㪞㪄㪈 㪚㪦㪤㪤 1 㪪㪧 㪈 㪉 2 1 1 Leave program 6 㪧㪩㪦㪞㪄㪈 㪪㪧 㩷 㪈 㩷 㪉 㫄 㪹㪸㫉 ENTRER ENTRER 1 1 7 16/16 Back to initial screen Alcatel Vacuum Technology France - User's Manual ACS 2000 GB 03438 - Edition 03 - October 09 2 ENTRER CHINA JAPAN SWEDEN Alcatel Vacuum Technology, Shanghai N°82 Lane 887 Zuchongzhi Road Zhangjiang High-Tech Park, Shanghai 201203 China Tel. (86) 21 5027 0628 Fax. (86) 21 3895 3815 Alcatel-Lucent Japan Ltd. 1-9-4 Kita Shin-Yokohama Kohoku-ku Yokohama, Kanagawa 223-0059 Japan Tel. (81) 3 6431 7130 Fax. (81) 45 544 0049 Adixen Sensistor AB. Box 76 SE-581 02 Linköping Sweden Tel. 46 (0)13 35 59 00 Fax. 46 (0)13 35 59 01 GERMANY KOREA TAIWAN Alcatel Hochvakuumtechnik GmbH Am Kreuzeck 10 - Postfach 1151 97877 Wertheim Germany Tel. (49) 9342 9610 0 Fax. (49) 9342 9610 30 Alcatel Vacuum Technology Korea 315-2 Banwol-dong, Hawsung-si, 445-330 Kyungki-do, South Korea Tel. (82) 031-206-6277 Fax. (82) 031-204-6279 Alcatel Vacuum Technology Taïwan No. 169-3, Sec.1, Kang-Leh Rd Song-Lin Village, Hsin-Feng 304 Hsin-Chu County Taïwan - R.O.C. Tel. (886) 3 559 9230 Fax.(886) 3559 9231 INDIA NETHERLANDS UNITED KINGDOM Alcatel Vacuum Technology India Deepak 812, 8th Floor, Park Centra, Sector-30, Gurgaon - Haryana - 122 001 INDIA Tel. (91) 124-4737777 Fax. (91) 124-4737799 ALCATEL Vacuum Technology Benelux Landzichtweg 60 NL 4105 DP Culemborg The Netherlands Tel. (31) 345 478 400 Fax. (31) 345 531 076 Alcatel Vacuum Technology UK Ltd 8 Bain Square - Kirkton Campus Livingston - West Lothian EH54 7DQ - Scotland United Kingdom Tel. (44) 1 506 418 000 Fax. (44) 1 506 418 002 ITALY SINGAPORE USA Alcatel Vacuum Systems Via Trento, 30 20059 Vimercate (Mi) Italy Tel. (39) 0396 86 38 55 Fax. (39) 039 66 71 25 Alcatel-Lucent Singapore 49 Jalan Pemimpin #01-02 APS Industrial Building 577203 Singapore Tel. (65) 6254 0828 Fax. (65) 6254 7018 Alcatel Vacuum Products 67, Sharp Street Hingham - MA 02043 USA Tel. (1) 781 331 4200 Fax. (1) 781 331 4230 Alcatel Vacuum Technology France - 98, avenue de Brogny - BP 2069 - 74009 Annecy cedex - FRANCE Tel. (33) 4 50 65 77 77 - Fax. (33) 4 50 65 77 89 Web site: www.adixen.com ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Single-channel control
- Gauge compatibility
- Setpoint management
- RS232 communication
- Pressure display
- Error messaging
- Test mode
- Factory settings
Frequently asked questions
The ACS 2000 can be used with the following gauges: PIRANI gauge (AP 2004 - APN 2004), Combined PIRANI/Cold cathode gauge (ACC 2009), Combined CRYSTAL/Hot cathode gauge (AHC 2010), and Capacitive gauges (ASD 200X series, ARD 200X series).
The ACS 2000 is specifically designed to work with the gauges listed in the manual. Using incompatible gauges may not work properly or could damage the device.
You can adjust the pressure set points (SP1 and SP2) through the controller's settings menu. Each set point has two thresholds: SP-xH (high) and SP-xL (low). The set point opens when the pressure goes below the low threshold and stays open until the pressure crosses the high threshold.
The gas correction factor is used to adjust the pressure reading for gases other than nitrogen (N2). It affects both the pressure readout and the switching thresholds of the set points.
The ACS 2000 has a built-in RS232 interface. Use a standard RS232 cable to connect it to your computer. Refer to the manual for detailed instructions on RS232 communication and available commands.