Airwell | AWSI-FWD018-N11 | FWD - Certus

FWD
Floor & ceiling
low temperature
FWD Floor & ceiling low temperature
product functions
features
loor ceiling line available in capacities 3.5 up
F
to 6.8 kW.
Cooling operation mode.
Glossy designed unit.
DC Inverter technology.
“I feel” function with precise room temperature
control.
Low temperature.
edicated design for wine cellars. Cooling
D
operation up to -10ºC outside and go down up
to 12ºC inside.
Precharge to max tubing length up to 20 m.
Fresh air supplied.
Fuzzy logic to control compressor by outdoor
fan and electronic expansion valve in extrem
low operation temperature.
Cooling
Indoor Units
AWSI-FWD 012-N11
AWSI-FWD 018-N11
Outdoor Units
GC 12 RC DCI
AWAU-YBD018-H11
AWAU-YBD024-H11
Capacity
kW
3.5 (1.5-4.0)
5.0 (1.5-5.8)
6.8 (1.5-7.6)
Input power
kW
1.09
1.51
2.25
3.21/A
3.31/A
EER/Energy Label
Indoor
unit
°C
Sound pressure level to 1 m (LS/MS/HS)
dB(A)
30/41/45
40/48/51
46/51/54
Sound power level (LS/MS/HS)
dB(A)
51/53/56
56/60/65
58/63/66
Airflow
m3/h
300/400/450
600/750/870
800/950/1020
Dehumidification
l/h
1.5
2
2.5
Dimensions (WxDxH)
mm
820x190x630
1200x190x630
1200x190x630
Weight
kg
22
30
32
7SP012181
7SP012182
Pipe Line
-10°/46° Dry Bulb
7SP012183
Sound pressure level to 1 m
dB(A)
55
53
56
Sound power level
dB(A)
65
63
69
Airflow
m3/h
1460
2160
3600
Rotary DC Inverter
Rotary DC Inverter
Twin Rotary DC Inverter
Compressor type
Power
supply
1~230V - 50 Hz
3.02/B
Outdoor temperature operating limits
Part number
Outdoor
unit
AWSI-FWD 024-N11
Dimensions (WxDxH)
mm
760x245x545
795x290x610
950x412x835
Weight
kg
37
38
64.5
Part number
7SP061619
7SP061738
7SP061762
Power supply side
Indoor
Indoor
Outdoor
Power cable section
mm2
3x1.5
3x2.5
3x2.5
Fuse rating am
A
16
20
25
Electrical connections
mm2
4x1.5
4x2.5
4x2.5
Suction pipe diameter
inches
3/8”
1/2”
5/8”
Liquid pipe diameter
inches
1/4”
1/4”
3/8”
Max length
m
15
20
30
Max height
m
10
10
15
FLEXY
MATCH
DC Inverter
flexy match
Low
Sine wave
compressor drive
Low voltage
startup
R410A
Low
Low temperature
startup
R410A FLUID
Motorized 2D
airflow
STBY
Unit ON output
ODU
ODU
outdoor unit
Stand-by switch dry
contact
outdoor unit
Alarm output
I FEEL
Sleep mode
Programmable
Timer
Self diagnosticLED
Low battery
indication
Auto Restart
ODU
ODU
Presence
detector output
Service monitor
tool
Power
consumption
control
Remote control
diagnostic
Outdoor unit
digital diagnostic
outdoor unit
Night mode dry
contact
UNIT
ON
Alarm output
Anti dust
and UV casing
RESTART
24 H
Wide angle louver
TEST
MODE
Full length refrig
precharge
Technician test
mode
-
CM FWD GB 0312 - Specifications subject to change without notice. Pictures non contractual. Printed in UE.