Bosch | ICP-AMAX-P3-EN | AMAX panel 2100 family - Bosch Security Systems

Intrusion Alarm Systems | AMAX panel 2100 family
AMAX panel 2100 family
www.boschsecurity.com
The intrusion alarm system AMAX panel 2100 family is
designed for residential and small to medium-sized
businesses. It offers 8 zones and 2 areas and comes
with an enclosure and a transformer.
An on-board PSTN dialer transmits an alarm via the
common telephone network to a phone and / or a
communication center while at the same time a voice
message is sent to the owner’s landline or mobile
phone to inform him about an intruder’s presence.
Commissioning the system is simple and involves
minimum programming: the default settings already
cover 90 % of the available functionality. Programming
can either be done via the AMAX TEXT, LCD and LED
keypads or via the programming software (A-Link
Plus).
The intrusion system can be used with hardwired
detectors from Bosch.
u
8 Hardwired zones / 2 Areas / 64 User codes
u
3 x 256 Events log stamped with date and time
u
On-board voice dialer
u
Macro functionality
u
USB direct connection
System overview
Option Bus
PSTN
Telephone
Network
CMS
Phone
Programming SW
A-Link Plus
2 | AMAX panel 2100 family
Functions
Compatibility Information
The AMAX panel 2100 family is an 8 zone / 2 area
intrusion panel with enclosure and transformer. The
system includes a PSTN dialer to transmit an alarm via
the common telephone network. Transmit an alarm to
a phone and a communication center. Program the
control panel easily with the AMAX TEXT, LCD and LED
keypads or through the remote programming software
( A-Link Plus).
Basic
Basic functions
• Keypad code STAY / AWAY Arming
• One button STAY / AWAY Arming
• On-board dialer with CID / SIA transmission format.
Voice dialer transmits up to 4 recorded messages to
landline/mobile phones in case of an alarm. Record
messages with a PC and send to the control panel
with the remote programming software, A-Link Plus.
• Up to 16 weekly schedules and exceptions can be
programmed in the calendar.
• 3 programmable macros: several single functions
from the keypad are combined to one customer
macro function and executed by pressing one button.
• Program the control panel with the new release of
remote programming software A-Link Plus. All control
panel and status information is accessible.
• Execute remote maintenance operations (e.g. Walk
Test, Bypass).
• In multi area set-up (direct and multiple arming),
“area status” is displayed.
• Display Area Name in the master keypad.
• 3 on-board outputs (two monitored)
• Use any zone with four-wire fire detectors.
• Use any zone with Chime Mode (door bell)
• Use any zone to detect Sensor Tamper (DEOL)
• Test Mode for outputs and zones
Optional functions
• Zone inputs on extension modules (with DX2010)
• Relay outputs on Extension module (with DX3010)
• Connect outdoor sirens and IP cameras to an optional
8 relay module (DX3010)
• Programming key
Optional Alarm Transmission
• IP communication with Bosch Conettix IP / SIA DC09
(UDP) Protocol via B426 module
• GPRS communication with Bosch Conettix IP l / SIA
DC09 (UDP) Protocol via B450 module
Optional Remote Programming
• IP (B426 module)
• GPRS (B450 module)
Optional Video Alarm Verification
Realized in combination with the DX3010 8 relay
module and the IP 200 camera series of Bosch. The
live video verification ensures a location check and
false alarm reduction via Internet from every location
worldwide. This means that you or the monitoring
center can get alarm notification in order to detect the
exact location the alarm was triggered and if a real
intruder is present.
PSTN Communicator (Integrated)
Formats:
Contact ID, SIA
Magnetic Contacts (1)
All magnetic contacts, including
recessed, terminal connection,
miniature over-head door, and
surface mount.
Intrusion Detectors (1)
All conventional intrusion
detectors, including Blue Line,
seismic, PIR, TriTech,
photoelectric and TriTech PIR
Microwave.
Four-wire Smoke Detectors (1, 2)
Conventional 12V smoke, heat
and photoelectric smoke
detectors.
Optional (1, 2)
Zone
DX2010 zone input module
Relays
DX3010 output module
IP-Communicator
B426 Ethernet Network Interface
Module
GPRS/GSM Communicator
B450 Module
Assorted literature is available. Refer to the
appropriate datasheet, brochure, and installation
guide for additional data.
Availability varies according to sales region.
Certifications and approvals
Region
Certification
Europe
CE
AMAX panel 2100 family, AMAX panel
3000 family
EN5013
1
EN-ST-000166 ICP-AMAX2-P2-EN, ICPAMAX2-P3-EN, ICP-AMAX3-P2-EN, ICPAMAX3-P3-EN
France
AFNOR
1223400002 ICP-AMAX2-P2-EN, ICPAMAX2-P3-EN
Sweden
INTYG
14-523 ICP-AMAX2-P3-EN
Parts included
CTN
Pcs
Description
AMAX panel 2100
family
1
8 zone / 2 areas intrusion panel
with enclosure and transformer,
tamper, integrated PSTNCommunicator
1
User Manual
3 | AMAX panel 2100 family
Technical specifications
Battery
Electrical
Battery type
12 V / 7 Ah
Bosch D 126
Low battery condition in VDC
below 11.0
Minimum battery condition in
VDC
10.8
Power supply type
EN = A
Transformer
Transformer input in VAC
230
Transformer output in VAC
18
Transformer AC power in VA
20
Transformer fuse in mA
500
Mechanical
AC input
Dimension in cm (H x W x D)
26.0 x 28.0 x 8.35
Weight in g
1950
Panel features
Minimum operating voltage in
VDC
195
Maximum operating voltage in
VDC
253
Line voltage frequency in Hz
50
Number of zones
8
Number of users
64
Number of events
256 history events, stamped with
time, and date
256 EN history events, stamped
with time, and date
256 dialer history events,
stamped with time, and date
Pin code variations
1000000
DC output
DC output maximum current for
all components in mA
DC output maximum current for
all components: dependency on
battery
1100
• Battery 7Ah standby 12h
(recharge Batt 80% in
72h) = 550mA
• Battery 7Ah standby 36h
+ 15min alarm current
500mA (recharge Batt
80% in 72h) = 150mA
Aux 1 / 2 output
Number of devices
Number of keypads
4
Number of DX 3010 modules
1
Number of DX 4010 modules
1
Number of GPRS modules: B450
with B442 or B443, DX4020-G
Up to 2 different GPRS modules,
each GPRS module can only be
connected once
Number of IP modules: B426
2 (1 if 1 of the GPRS modules
above is connected, 0 if 2 of the
GPRS modules above are
connected)
Aux 1 / 2 output voltage
+12V / GND
Aux 1 / 2 nominal output voltage
under AC line input in VDC
13.8 (+3% / -5%)
Aux 1 / 2 output max. Vpp in mV
675
Aux 1 / 2 output voltage range
under AC line input in VDC
12.82 – 13.9
Aux 1 / 2 output current in mA
500
Zone 1
Single or dual end-of-line (EOL
2,2KΩ)
NC, NO
PO -1 / PO -2 maximum
supervised output current in mA
500
Zone 2 – 16 COM
PO -3 maximum current in mA
100
7 Single or dual end-of-line (EOL
2,2KΩ)
NC, NO
Tamper
Enclosure tamper input (does not
reduce point capacity)
Zones
Outputs
Option bus
Option bus nominal output
voltage under AC line input in VDC
13.8 (+3% / -5%)
Option bus output voltage range
under AC line input in VDC
13.11 – 14.2
Option bus 1 maximum current in
mA
500
Panel PCB maximum quiescent
current in mA
100
Option bus
Dimensions in mm
4 wire, Ø 0.6 – 1.2
Maximum cable length in m
200 (panel to last keypad)
Maximum bus length in m
700 (maximum 14 devices,
maximum 8 keypads)
4 | AMAX panel 2100 family
Environmental
AE20EN Enclosure
AE20EN plastic enclosure for DX2010/DX3010.
Minimum operating temperature
in °C
-10
Maximum operating temperature
in °C
55
B426 Ethernet Communication Module
Minimum relative humidity in %
10
Supports two-way communications over Ethernet
networks for compatible control panels.
Maximum relative humidity in %
95
Protection class
IP 30, IK 06
Ordering information
AMAX panel 2100
Language Package 1: English, Polish, Turkish
This product variant is not certified according to
European standards.
Order number ICP-AMAX2-P1
AMAX panel 2100 EN
Language Package 2: French, German, Dutch,
Portuguese
Order number ICP-AMAX2-P2-EN
AMAX panel 2100 EN
Language Package 3: English, Spanish, Polish, Swedish
Order number ICP-AMAX2-P3-EN
Accessories
AMAX keypad 2000 D8
AMAX keypad 2000 D8, 8 zones LCD Icon keypad.
Order number IUI-AMAX-LCD8
AMAX keypad 3000 L8
AMAX keypad 3000 L8 is a 8 zone LED keypad.
Approval: EN 50131-3 Grade 2
Order number IUI-AMAX3-LED8
AMAX keypad 3000 L16
AMAX keypad 3000 L16 is a 16 zone LED keypad.
Approval: EN 50131-3 Grade 2
Order number IUI-AMAX3-LED16
AMAX keypad 4000 T
AMAX keypad 4000 T, LCD text keypad, two lines with
each 18 characters.
Order number IUI-AMAX4-TEXT
ICP‑EZPK Programming Key
Blue key for transferring information to and from Easy
Series Intrusion Control Panels.
Order number ICP-EZPK
DX2010 Input Expander
Zone expansion module with 8 DOEL zone inputs.
Order number DX2010
DX3010 Octo‑output Expander
Package includes only the DX3010 board.
Order number DX3010
Order number AE20EN
Order number B426
B442 Conettix Plug-in GPRS Cellular Communicator
Multi-function cellular communicator that provides IP
communication over a (GPRS) cellular network.
Order number B442
B443 Conettix Plug-in HSPA+ Cellular Communicator
Multi-function 3G/4G cellular communicator providing
IP communication over a GPRS/EDGE/UMTS/HSPA+
cellular network.
Order number B443
B450 Conettix Plug-in Communicator Interface
Supports two-way IP communication over commercial
cellular networks using a plug-in Cellular
Communicator for compatible control panels.
Order number B450
5 | AMAX panel 2100 family
Represented by:
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2015 | Data subject to change without notice
13936253195 | en, V15, 13. Apr 2015
Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
China:
America Latina:
Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
203 Building, No. 333 Fuquan Road
Via Anhanguera, Km 98
North IBP
CEP 13065-900
Changning District, Shanghai
Campinas, Sao Paulo, Brazil
200335 China
Phone: +55 19 2103 2860
Phone +86 21 22181111
Fax: +55 19 2103 2862
Fax: +86 21 22182398
latam.boschsecurity@bosch.com
www.boschsecurity.com.cn
www.boschsecurity.com
Download PDF