G3…(D) 3-way Globe Valve, Bronze Trim Application This valve is typically used in Air Handling Units on heating or cooling coils and Fan Coil Unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV Box reheat coils and bypass loops. This valve is suitable for use in a hydronic system with constant or variable flow. 3-way valves are available with mixing or diverting flow patterns. N40021 - 03/13 - Subject to change. © Belimo Aircontrols (USA), Inc. bronze bronze stainless steel brass spring loaded TFE none ANSI 250 (up to 400 psi below 150°F) ANSI III SVK Series LVK Series LF Series A Valve Body G314 G315(D) G320(D) G325(D) G332(D) G340(D) G350(D) *(50% or more open) G3…D 3-way Diverting Valve A Stem Up- Open B to AB Dimensions B 20°F to 250°F (-7°C to 120°C) 35 psi (241 kPa) 500:1 G314, G315(D) 2 lbs G320 3 lbs G320D 2.5 lbs G325, G332(D) 2.5 lbs G325D 5 lbs G340(D), G350(D) 14 lbs G3...(D) 3-way Flow Patterns G3 3-way Mixing Valve G314 G315(D) G320(D) G325(D) G332(D) G340(D) G350 G350(D) D078-3W G3 G3...D chilled or hot water, 60% glycol linear stem up - open B to AB stem up - open B to AB ½” to 2” NPT female ends 15 15 20 25 32 40 50 50 AF(X) Series Service Flow characteristic Action Sizes End fitting Materials Body Seat Stem Plug Packing Disc ANSI class Leakage Media temperature water Maximum ΔP* water Rangeability Valve weights ½ ½ ¾ 1 1¼ 1½ 2 2 2.2 4.4 7.5 14 20 28 41 40 3-way NPT Suitable Actuators Spring Electronic Fail- Safe NF Technical Data Inches DN [mm] NonSpring SV Series Cv Type LV Series Valve Nominal Size Valve Nominal Size Inches DN [mm] ½” 15 ½” 15 ¾” 20 1” 25 1¼” 32 1½ 40 2 50 Dimensions (Inches [mm]) A B 3.06” [78] 3.06” [78] 3.62” [92] 4.62” [117] 4.62” [117] 5.37” [137] 6.12” [156] 1.37” [35] 1.37” [35] 1.68” [43] 1.56” [40] 1.62” [41] 1.62” [41] 1.87” [48] Piping The valves should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. Allow sufficient room for valve with actuator and for service. Please allow 12” for complete actuator/linkage removal. The G2(S) and G3(D) preferred mounting position of the valve is with the valve stem vertical above the valve body, for maximum life. However, the assemblies can be mounted with the valve stem vertical or horizontal in relation to the pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. Do not reverse flow direction. Stem Up- Open B to AB Note: Flow B to A travels through center of plug (as shown). 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 9 LVB24-3 On/Off, Floating Point, Non-Spring Return, Linear, 24 V Application For On/Off and floating control types of globe valves in HVAC steam and hydronic systems. Actuator sizing will be dictated by the valve size selection. All valve selections should be done in accordance with the flow parameters and system specifications. The actuator is mounted directly to the globe valve bonnet by means of its universal clamp and collar. The actuator operates in response to a 24 volt signal being applied from an electronic controller or positioner. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The LV series provides 15 mm of downward travel and a visual indicator indicates position of the actuator. When reaching the valve end position, the actuator automatically stops. The gears can be manually disengaged with a button on the actuator cover. The LV… series actuators use a sensorless brushless DC motor. The ASIC inside monitors and controls the actuator’s rotation and provides a digital rotation sensing (DRS) function to prevent damage to the actuator in a stall condition. Power consumption is reduced in holding mode. Technical Data Noise level Servicing Quality standard Weight Dimensions (Inches [mm]) 7.8” [199] 1.8” [45] 3.9” [98] † Use flexible metal conduit. Push the Listed conduit fitting device over the actuator’s cable to butt against the enclosure. Screw in conduit connector. Jacket the actuators input wiring with Listed flexible conduit. Properly terminate the conduit in a suitable junction box. Rated impulse Voltage 800V. Type of action 1. Control Pollution Degree 3. 800-543-9038 USA 249 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN P10401 - 01/13 - Subject to change. © Belimo Aircontrols (USA), Inc. Humidity Ambient temperature Storage temperature Housing Housing material Agency listings† Add-on auxiliary switches are easily fastened directly onto the actuator body for signaling and switching functions. 5.9” [150] Overload protection Electrical protection Control Operating Range Y Input impedance Feeback Output U Stroke Linear Force Direction of rotation Position indication Manual override Running time motor 24 VAC ± 20% 50/60 Hz, 24 VDC ± 10% 2W 0.5 W 5 VA (class 2 power source) 3 ft, 18 GA plenum rated cable with 1/2" conduit connector protected NEMA 2 (IP54) electronic throughout full stroke actuators are double insulated on/off, floating point on/off, floating point 100 k (0.1 mA), 500 , 1000 (on/off) No Feedback 0.6" [15 mm] 112 lbf [500 N] reversible with switch stroke indicator on bracket 4 mm hex crank (shipped with actuator) 90 seconds (default), variable (90 to 150 seconds) 5 to 95% RH non condensing -22°F to +122°F [-30°C to +50°C] -40°F to +176°F [-40°C to +80°C] NEMA 2, IP54, UL enclosure type 2 Aluminum die cast and plastic casing cULus acc. to UL 60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/EC <55dB(A) maintenance free ISO 9001 2.9 lbs 6” [152] Power supply Power consumption running Power consumption holding Transformer sizing Electrical connection LVB24-3 On/Off, Floating Point, Non-Spring Return, Linear, 24 V Typical Specification Wiring Diagrams On/Off, floating control globe valve actuators shall be electronic and direct coupled to the globe valve bonnet via an integrated linkage, which requires no secondary linkage and be capable of mounting to valves ½” to 2” in size. Actuators must provide control in response to a control input from an electronic controller or positioner. Actuators shall have brushless DC motor technology and be protected from overload at all angles of rotation. Actuators shall have reversing switch and manual override on the cover. Run time shall be constant and independent of torque. Actuators shall be cULus listed, have a 5-year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by Belimo. CAUTION Equipment Damage! 2 Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. 1 18 Actuators with plenum cable do not have numbers; use color codes instead. Meets cULus or UL and CSA Standard requirements without the need of an electrical ground connection. WARNING G Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 24 VAC Transformer 2 3 18 Blk (1) Common Line Volts Red (2) + Wht (3) + On/Off Line 24 VAC Transformer (AC only) P10401 - 01/13 - Subject to change. © Belimo Aircontrols (USA), Inc. Volts 2 Hot Com Blk (1) – Common Red (2) + Hot Wht (3) Y1 Input Controller Triac Sink Line 24 VAC Transformer (AC only) Volts 2 Hot Com Blk (1) – Common Red (2) + Hot Controller Wht (3) Y1 Input Triac Source 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA / CARIBBEAN 250 Close-Off Pressures (psi) G2/G3 Non-Spring Return, Spring Return, and Electronic Fail-Safe Non-Spring Return LV 2-way G212(S) G213(S) G214(S) G215(S) G219(S) G220(S) G224(S) G225(S) G232(S) G240(S) G250(S) SV 250 250 250 250 211 211 Spring Return LF G315 G320 G325 G332 G340 G350 LVK 207 207 236 159 85 210 120 250 210 250 250 211 210 140 250 250 250 250 220 140 250 236 159 85 210 120 250 250 250 250 250 250 250 250 250 250 250 250 N40021 - 03/13 - Subject to change. © Belimo Aircontrols (USA), Inc. 250 250 250 250 SVK 250 250 250 250 211 211 220 220 140 250 236 159 85 3-way Diverting G315D G320D G325D G332D G340D G350D Electronic Fail-Safe AFB 250 250 250 250 140 140 250 250 236 159 85 3-way Mixing G314 NF 800-543-9038 USA 88 866-805-7089 CANADA 203-791-8396 LATIN AMERICA Close-Off Pressures (psi) G6/G7 Non-Spring Return, Spring Return, and Electronic Fail-Safe Non-Spring Return N40021 - 03/13 - Subject to change. © Belimo Aircontrols (USA), Inc. EV RV Spring Return AF 2-way Pressure Comp ANSI 125 G665C G680C G6100C G6125C G6150C 140 140 140 140 140 140 140 2-way Pressure Comp ANSI 125 G665CS, G665LCS G680CS, G680LCS G6100CS, G6100LCS G6125CS, G6125LCS G6150C, G6150LCS 125 125 125 125 125 125 125 2-way Pressure Comp ANSI 250 G665C-250 G680C-250 G6100C-250 G6125C-250 G6150C-250 310 310 310 310 244 310 280 2-way Pressure Comp ANSI 250 G665CS-250, G665LCS-250 G680CS-250, G680LCS-250 G6100CS-250, G6100LCS-250 G6125CS-250, G6125LCS-250 G6150CS-250, G6150LCS-250 250 250 250 250 244 250 250 3-way ANSI 125 Mixing G765, G765S G780, G780S G7100, G7100S G7125, G7125S G7150, G7150S 3-way ANSI 250 Mixing G765-250, G765S-250 G780-250, G780S-250 G7100-250, G7100S-250 G7125-250, G7125S-250 G7150-250, G7150S-250 3-way ANSI 125/250 Diverting G765D, G765DS, G765DS-250 G780D, G780DS, G780DS-250 G7100D, G7100DS, G100DS-250 G7125D, G7125DS, G7125DS-250 G7150D, G7150DS, G7150DS-250 800-543-9038 USA Electronic Fail-Safe 2*AF AVK 140 140 110 140 140 140 140 140 125 125 125 110 125 125 125 125 125 280 185 110 310 310 310 232 150 250 185 110 250 250 250 232 150 2*GK 250 94 63 33 125 125 68 42 28 40 26 100 68 12 71 47 125 125 37 94 63 33 185 125 68 42 28 40 26 100 68 12 71 47 222 152 37 22 14 140 140 140 140 175 140 140 140 140 140 140 140 175 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 89
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement