Dacor | MRES30 | MRES30 - Datatail

MRES30
Document # PG05-005
Revised 05/14/10 Page 1/2
30 Inch Wide
Millennia® Electric Range
PLANNING
GUIDE
All tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated
warning
•
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
This appliance must be installed in accordance with the
accompanying installation instructions.
The optional full size side panels are for installation where the side of the
range will not be covered by the cabinet. For the right side panel, order
Dacor part number ARSR30S. Order part number ARSL30S for the left
side.
60” (1524mm) long
240 Vac 4 wire
conduit location
Dedicated Circuit Required
Total Connected Load
240 Vac, 60 Hz., 4-wire*, 50 Amp.
12.5 kW (48.2 Amp.)
electrical Requirements
The above specifications are for reference only. See the product data label
for exact specifications.
Optional full
size side panel
36" (914mm) Recommended
30" (762mm) Min.
Hood
13"
(330mm)
Max.
25"
(635mm)
Removable (factory installed)
3” (76mm) side panels
product dimensions - ISO View
18" (457mm)
Min.
30"
(762mm)
Vertical
combustible
surface
30" (762mm) 30 1/16"
(764mm)
Min.
Top of
finished
counter
10"
(254mm)
10"
(254mm)
1
14"
(356mm)
10" (254mm) Min.
to combustible side
walls above the range
(both sides)
2
Range top
Rear of control
Panel/oven door
Door opened
23 1/2"
(597mm)
25 5/16"
(643mm)
Max. depth
to oven door
handle with
door closed
45 1/4"
(1149mm)
Freestanding Cutout Dimensions
For self-rimming cutout dimensions, see the following page.
product dimensions - top View
NOTES:
1.
2.
Electrical is located in the right rear corner of the unit.
Range is supplied with a 60” (1524 cm) long 240V 4-wire conduit.
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
www.Dacor.com
Phone: (800) 793-0093 5.12
MRES30
Document # PG05-005
Revised 05/14/10 Page 2/2
30 Inch Wide
Millennia® Electric Range
PLANNING
GUIDE
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Backsplash
Vertical
non-combustible
surface rear wall
1/4" (6mm)
Min. flat ledge
Rear wall
25"
(635mm)
Adjust for backsplash
thickness
13/16" to 4 1/4"
(21 - 108mm)
28 11/16" (729mm)
29 5/8" (752mm)
11/16"
(17mm)
Top View - Slide-In, Self-Rimming Installation using 3” Side Panels
(Part Numbers ARSR30 and ARSL30) with Backguard Removed
Vertical
non-combustible
surface rear wall
Backsplash
thicker than
3/4" (19mm)
27 7/8" (708mm)
27 13/16"
(706mm)
1/4" (6mm)
Min. flat ledge
2 13/16"
(71mm)
Adjust for backsplash
over 3/4" thick
from 13/16" to 3 13/16"
(21 - 97mm)
13/32" (10mm)
29 1/4" (743mm)
30 1/16" (764mm)
Countertop overhangs cabinet
10" (254mm) Min.
to combustible side
walls above the range
(both sides)
Top View - Downdraft ERV30 with Slide-In, Self-Rimming Installation using 3” Side Panels
(Numbers ARSR30 and ARSL30), with Backguard Removed
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
www.Dacor.com
Phone: (800) 793-0093 5.13
Download PDF