CLE0812


Add to my manuals
2 Pages

advertisement

CLE0812 | Manualzz
Project ________________________________
™
Cleveland
Item __________________________________
CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
Approval _______________________________
Cleveland Classic Series
Quantity _______________________________
FCSI Section ____________________________
CONVECTION
STEAMERS
Date __________________________________
MODELS: 36-CGM-300
TWO COMPARTMENT, PRESSURELESS
GAS FIRED STEAM GENERATOR, with NICKELGUARD™
200, 250, 300M BTU, 36” WIDE CABINET BASE DESIGN
Cleveland Standard Features
I Cooking Capacity for up to six 12˝ x 20˝ x 21⁄2˝ deep Cafeteria Pans.
I Pressureless cooking with forced convection steam,
permitting doors to be opened while cooking continues.
I Solid State Controls operate water level and safety functions.
I Each compartment is equipped with a 60 minute mechanical
I
I
I
I
I
I
I
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN. MT.
NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY, Wash. DC)
™
I
d
I
I
Ye
a
5
I
100 %
I
elGuar
ck
ra nty
I
I
Shown with optional
Electronic Timer
ar
I
Ni
I
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.
Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.
Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
Separate Main Power Switch for “On/Off”
Exclusive Steam Cooking Distribution System: The
exclusive Convection Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly and is easy to
keep clean. Creased top & bottom enhance drainage. Cold
Water Condenser for each compartment maintains a dry
steam. Fully insulated cooking compartment for thermal
efficiency. Removable Stainless Steel Slide Racks for easy
cleaning.
Exclusive “Cool to the Touch” Compartment Door
Design: Free floating inner door with reversible door gasket
provides an air tight seal. Stainless Steel Slam/Latch Door
Latch mechanism provides greater reliability.
Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
Modular Cabinet Base with Hinged Door.
High Efficiency Gas Steam Generator with NickelGuard,
Electronic Spark Ignition and Automatic Water Fill on start up.
Automatic Generator Drain at shutdown: Contains a
“Water Jet” Spray Rinse Cleaning Cycle to keep drain clear.
Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
Steam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Generator Pressure
Gauge.
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
Gas Pressure Regulator and Control Valve.
Standard Voltage for Controls: 115 volts, 60 Hz, single phase.
All Controls are serviceable from the front.
Secondary Low Water Cut-Off, factory installed (CALG)
r B o il e r
W
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 36CGM- _____ , Gas-fired Steam Generator, NickelGuard, _____ M BTU. Solid
State Controls operate timing, water level and safety functions. Steam
Generator with Automatic Water Fill on start-up, Automatic Blowdown with
additional Manual Drain Valve and Electronic Spark Ignition. For each cooking compartment: 60 minute Mechanical Timer, Manual Operation Mode and
Cold Water Condenser. Type 304 Stainless Steel cooking compartment.
Options & Accessories
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Ë
Right Hand Door Hinging, Controls on the Left (DHR)
Electronic Timer with Compensating Load Feature (ETC)
ON/OFF Steam Switch only for compartment controls (MC)
Cafeteria pans in depths of 1˝, 21⁄2˝, 4˝ and 6˝
Compartment Door Steam Shut Off Switch (SCS)
Power Take Off Kit (GPTO), Kettle Interconnecting Kit (IMK)
Stainless Steel Base Frame (FSS)
Stainless Steel Insulated Flue Cover (SSF)
Quick Disconnect for gas line (QDC)
Correctional Packages
Boiler Descaling Pump Kit (107142)
Water Filters
Rear Gas Connection (RGT)
SECT.
1333 East 179 St.,
Tel: 1-216-481-4900
Web Site: www.ClevelandRange.com
Cleveland, Ohio, U.S.A. 44110
Fax: 1-216-481-3782
Email: [email protected]
E. Friedman Associates Inc.
III
11
PAGE
0609
Each compartment has capacity for:
• Three, 12˝ x 20˝ x 21⁄2˝ or six, 12˝ x 20˝ x 1˝ deep
Cafeteria Pans.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof
that it will be suitable for the generator.
Right - 6”, Left - 6”, Rear - 6” (12”
on control side if adjoining wall
or equipment is over 30” high for
service acess)
** Do not connect to GFI
outlet. See note below.
NOTES:
1 1/2” IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.
For use in noncombustible locations.
Contact factory for
variances to clearances
**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA (AGA, CGA).
E. Friedman Associates Inc.
III
12
(NOT TO SCALE)
SECT.
PAGE
0609
Litho in U.S.A.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement