Dwyer Model 8904 Operation Manual
Add to my manuals19 Pages
Mastech Model 8904 is a versatile digital anemometer that measures air velocity, flow, and temperature with high accuracy and a fast response time. It features a large, easy-to-read backlit display, and a durable housing that can withstand harsh conditions. The 8904 is ideal for a wide range of applications, including HVAC/R, industrial, and environmental monitoring.
Some of the key features of the Mastech Model 8904 include:
- Measures air velocity, flow, and temperature
- Large, easy-to-read backlit display
- Durable housing that can withstand harsh conditions
- Fast response time
- Versatile, with a wide range of applications
advertisement
OPERATION MANUAL
RS232
INTEGRAL VANE
DIGITAL ANEMOMETER
Model:8903/8904/8906
Model:
8903
8904
8906
Congratulations on your purchase of this Integral vane anemometer.
The meter features versatile functions, use it to check air velocity FPM (Feet per minute) and CFM (Cubic feet per minute) in residential , light commercial and standard commercial systems.
Thank you for selecting the meter.
Please read this operation manual throughly before operation.
This meter has many user-friendly features, all the features are accessible through the keypads.
Please contact the store or the place you purchased for the rest models you might interested in.
The meter is most ideal for HVAC/R technicians measuring Heat / Ventilation
/ Air conditioning / Refrigerating wind flow and temperature.
CAUTION: Objects strike the fan may
damage the meter.
Model:
Knot, MPH,
KM/H
Air Flow
Volume
AZ8903
AZ8904
AZ8906
No
Yes
Yes
1
No
No
Yes
FEATURES
A. Measuring Air Velocity (Single point)
Feet per Minute (FPM).
B. Continuous Moving Average.
C. MIN/MAX/AVG reading on a single
point.
D. Air Velocity average for multiple
points ( 8904.8906 model only).
E. Non Sleep Mode(Bypass auto power
off).
F. Default setting ( Imperial/ Metric)
G. RS232 interface setting.
H. Auto power off function.
I. FTM , MPH , KNOT unit selectable
(8904.8906 model only).
J. Direct measuring of air flow
(Single point) CFM ( 8906 only).
K. Obtain air flow (CFM) average
for multi-point ( 8906 only).
Typical Measurement a) Please place the meter in the
airstream. Make sure that the
airstream and the sensor
are aligned as shown ( 20
degrees maximum).
20 o b) 3 seconds for the
reading to stabilize .
20 o
Rear side
2
FRONT PANEL DESCRIPTION
Model:8903
HOLD
AVERAGE
MULTI-POINT
MIN/MAX REC
SINGLE-POINT
Model:8904
O N-O /RE
SET
F EE AR
AF
IT
LO
Y
W
AV RAG
ON T
S L-M
K
IL
- N
/H
T
MIN/M
AX REC vel
F LO
W
Ho ld ft /m m/s m f
2
2
MI
N REC
MAX
AV
G
ON-OFF
RESET
HOLD
AVERAGE
MULTI-POINT
SEL -MIL/H
- KN OT
MIN/MAX REC
SINGLE-POINT
Model:8906
ON-OFF/RESET MODE-VELOCITY
FREE AREAFLOW
HOLD
AVERAGE
MULTI-POINT
SEL- MPH
- KNOTS
MIN/MAX REC
SINGLE-POINT
BUTTON / DISPLAY
1.ON/OFF- RESET. Power ON/OFF.
Press with HOLD key to set non-sleep
mode.
2.HOLD. Freezes the reading.
3.AVERAGE MULTI-POINT.
4.MN/MX RECORD SINGLE POINT
5.SEL:MIL/H (MPH) ,KNOT. unit
selectable .
(Model:8904 & 8906 only)
6.MODE VELOCITY, FREE AREA ,
FLOW. (Model:8904/8906 only)
Air volume measurement .
3
INDICATORS
1.vel. Air velocity measurement.
2.FLOW. Air Flow/Air volume.
3.AREA. Free area default setting.
4.Hold. Freezes the reading.
5.ft/m.
Feet per minute.
Feet square.(imperial) meter square.(metric)
8.cfm. Cubic feet per minute.(imperial)
9.cms. Cubic meter per second.(metric)
10.C. Celsius unit.
11.F. Fahrenheit unit.
12.REC. Record and saved.
13.AVG. Average data
14.MIN. Minimum data
15.MAX. Maximum data
16. Primary readout-Numerical display
for Air Velocity/ Air Volume/Free
area digit
17. Secondary readout -Temperature
display or records number.
18. "-" Polarity indicator for negative
temperature.
19. Knots.
(KN)=1850 meters per hour
20. Mil/h. or 1.15 miles per hour
(Imperial) Miles per hour
21. Km/h. (Metric) Km/h Kilometer per hour ve l FLOW AREA Hol d PH Kno ts ft/m ft 2 m/ s m 2 mi l/h cf m km/ h cms
MI N REC
MAX AVG
4
A. MEASURING AIR VELOCITY
(SINGLE POINT) FEET PER
MINUTE (FPM)
1. Press the ON/OFF button to turn the
meter on. Meter will show full display
for initial 5 seconds. (See Fig.1)
2. Unit is ready for use when LCD display
shows "vel" at upper left corner and
temperature at lower right corner.
(See Fig.2)
Fig.1
vel FLOW AREA Hold PH Knots ft/m m/s ft
2 m
2 mil/h cfm km/h cms
MIN REC
MAX AVG vel
Fig.2
ft/m
B. CONTINUOUS MOVING AVERAGE
The meter has the ability to display continuous moving average for up to two(2) hours.
1. Turn the power ON .
2. Place sensor in front of air flow
source.
3. Press MIN/MAX record key once.
An "AVG" and "REC" in the lower left
corner of the display to confirm the
meter is in continuous moving average
measurement mode. The display
will update every second.
(See Fig.3) vel m/s
Fig.3
REC
AVG
5
C. MIN/MAX/AVG READING ON A
SINGLE POINT
To obtain MIN/MAX/AVG readings on a single point.
1. Power the meter ON.
2. Place sensor in front of air flow
source.
3. Press MIN/MAX REC SINGLE POINT
key. The unit will begin to record
the readings.The meter displays the
average velocity by default.(see Fig.3)
Each press of the MIN/MAX button
cycles the display through:
* Real-time readings.
* MIN velocity.
* MAX velocity.
* Back to AVG velocity.
4. To revert to normal measurement
mode or clear the current MIN/MAX
and average readings, you could turn
off the meter first and then turn it on
again or press and hold MIN/MAX key
until meter beeps twice, then release.
Note: Feet Per Minute (FPM) readings
can be converted to CFM readings
by following below instructions:
1. Press the HOLD button to store
the readings before moving the
meter away from an air flow
sources.
2. Press MODE key to enter area
setting (see page11 for the details
of area setting). After setting, press
MODE key again to convert the
FPM into CFM.
6
D. AIR VELOCITY AVERAGE FOR
MULTIPLE POINTS(8904,8906 only)
1. Turn the meter on and position the
vane at the first point to be measured.
soon as the first measurement is
completed press the HOLD key,(you
will hear a single beep), and release.
The display will show HOLD above
the reading. (See Fig.4) vel Hold vel Hold m/s m/s ll ll
Fig.4
Fig.4-A
2. Press the MIN/MAX key,(You will hear
a single beep), and release,(the
display will show a digit 1-8). This
number represents the point number
which has been recorded.(See Fig.4-A)
3. Repeat above procedure until all
desired points have been measured
and recorded. A maximum 8 points may
be recorded at one time.
4. Once all measurements have been
recorded, you could vel Hold
press AVERAGE m/s
key to view the
average air velocity
reading and the
number of points
which are recorded.
AVG
Fig.5
5. You could press HOLD key to revert to
normal measurement mode
6. To clear multi- point average memory,
press and hold next digit/multi point
average key until unit beeps twice,
then release.
7
E. NON SLEEP MODE (Disable auto
power off)
Power unit off; press ON and HOLD at the same time and then release ON only.
An "n" appears on the LCD then you can release the HOLD key. The instrument will remain on until the OFF button is pressed.(See Fig.6 )
Fi g. 6
F. HOW TO CHANGE THE DEFAULT
SETTING/IMPERIAL TO METRIC
Vice Versa(METRIC TO IMPERIAL)
The default measuring units can be changed by following the steps below.
The unit should be turned off before commencing.
1. Press and hold the AVERAGE key,
then press the ON/OFF key once to
turn the unit on. When the LCD o o
displays " ft/m,ms " and " C, F"
realease the AVERAGE key.(Fig.7)
2. To choose the metric units, pressing the
HOLD key. The LCD should display " o
m/s, C". (See Fig.8)
Fi g. 7 m/s ft/m m/s
Fi g. 8
8
To choose the imperial units, pressing the
AVERAGE key. The LCD should display ft/m
Fig.9
3. Press the MIN/MAX REC key, the LCD
should display "S" (See Fig.10) .
Then press the HOLD key. The LCD
display 2400 or 1200 (pre-setting).
(If Baud rate change is needed, please
refer to step G.1) (See Fig.11)
Fi g. 10
Fig.11
.
4. Press the MIN/MAX REC key again,
the LCD should display "S" again.
(See Fig.10) .Then press the HOLD
key, the LCD will revert to a normal
measurement display. The default
setting is now completed.(See Fig.12) vel m/s
Fig.12
9
G.SETTING THE RS232 OUTPUT
(Optional accessory)
1. Following Step F.2, you will see a
"2400" (default) number on the screen.
The 2400 is the default setting of Baud
Rate for RS232 output. You can
change the setting to "1200" by
pressing HOLD Key and change the
setting back to "2400" by pressing the
AVERAGE key. (See Fig.13)
Fig.13
2. Please remember to save your
changes by pressing the MIN/MAX REC
key. An "S" displays on the LCD.
(See Fig.10).
Press the HOLD key to confirm and
save the changed value. The meter
will return to air velocity mode
automatically.
3. Plug the earphone jack of the cable
VZRS232M into RS232 socket on the
meter and connect 9-pin D-sub to the
computer's COM1 or COM2. Press
ON key to start measurement. The
length of the cable VZRS232M is 2M.
RS232 SOCKET
ON-O
F / F RESET
F E RF VEL O ITY
EA L O W
H O D
AR V E A
MU LTIPN -O
I T S EL-MIL
-
KN
/H
O T M N/
SING
MAX R
C
L -P O
E
INT
MIN
REC
A AV G v el
W E
Ho ld
PH K n o s ft/m m ft m k il/h m/ h c c
10
H. AUTO POWER OFF
The unit will turn off automatically after
20 minutes to save the battery. This will be preceded by 3 beeps.
I. MEASURING ft/m , MPH, Knot (Km/
Hour) (model 8904,8906 only)
In imperial , press SEL :.MPH . KNOT
Key, the reading will change from ft/m,
mil/h, knot in turns. In metric, press SEL
:.MPH. KNOT key, the reading will change
from m/s , km/h, knot in turn .
J. DIRECT MEASURING OF AIR
FLOW (SINGLE POINT) CFM
(model 8906 only)
Air Velocity measurement is calculated by multiplying the air velocity readings by the free area dimensions. Free area is published by the grill and register manufacturer you are servicing. You must first determine the free area of the air source before entering it into the meter.
AREA ft
2
Fig.14
1. Power unit on
2. Press MODE once. LCD will display
"AREA" and "1.111" will appear
(See Fig.14). The first digit will flash.
3. Press the HOLD key to increase the
number.
4. Press the AVERAGE key to advance
to next number. Follow Step 3 and
repeat to input the free area size.
5. Press the MODE key once all digits
have been entered. The word "flow"
will appear.
11
The meter is now ready to measure air flow(CFM).
K. TO OBTAIN AIR FLOW (CFM)
AVERAGE FOR MULTIPOINTS
(model 8906 only)
Simply complete steps 1~4 in D. Once all the multi-point average is determined:
1. Press MODE button once and confirm
correct free area setting is locked into
instrument. (if free area setting must
be adjusted make necessary changes
now.)
2. If free area setting is correct press
MODE button again to enter air flow
mode.
3. Unit will now display average air flow
reading and number of points measured.
L. MIN/MAX/AVG AIR VOL. READING
ON A SINGLE POINT (8906 only)
To obtain min/max/avg air volume readings on a single point, power the meter on, select the mode as FLOW and the place the sensor in front of the air flow source.
Press MIN/MAX/REC SINGLE POINT key, the unit will begin to record the reading. Press MIN/MAX key to read the real time value/MIN/MAX/AVG in turns.
Long press MIN/MAX key to clear the average readings.
The meter's free area dimension has been set to 1.111 square feet, a most commonly used free area dimension in the U.S.A. If you want to measure the air flow for a single point without changing the area dimension, please power on the
12
meter, position the fan and then press the
MODE key twice, you will be into the air flow(CFM) mode and the air flow(CFM) displayed is equal to the current air velocity reading (FPM x FREE AREA =
CFM) times the 1.111 square feet.
We would suggest to set the free area dimension before you start measuring the air velocity so after you measure the air velocity, you can jump to the air flow mode to view the cubic feet per minute without further changing the free area dimension.
Cubic equations:
Units Conversion Table:
1 m/s=
1 ft/min=
1 knots=
1 km/hr=
1 mph= m/s
1
0.00508
0.5144
0.2778
0.4464
ft/min
196.87
1
101.27
54.69
87.89
knots
1.944
0.00987
1
0.54
0.8679
1 m/s=
1 ft/min=
1 knots=
1 km/hr=
1 mph= km/hr
3.6
0.01829
1.8519
1
1.6071
mph
2.24
0.01138
1.1523
0.6222
1
Note:
On initial start up, the unit will show full display as fig.15 vel FLOW AREA although these features are only
Hold PH Knots ft/m ft 2 m/s m 2 mil/h cfm km/h cms available on models
8901, 04 and 06.
MIN REC
MAX AVG
13
Fig.15
TROUBLE SHOOTING
? LOW BATTERY
When the reading of display is flashing, or no display , please change the 9 volt battery in the meter .
Replace battery procedure:
Remove the screw from the lower back of the meter. Lift the cover out and remove the battery .Reverse the process to install a new battery and replace the cover .
? E6
Indicates the related circuits or parts of thermistor are failed. Send them back to the store you have bought for repairing.
? SENSOR'S FAN WILL NOT TURN
Indicates the sensor fan is damaged , purchase new sensor probe .
MATERIAL SUPPLIED
This standard package contains:
1.The meter x 1
2.Battery x 1 (9.0 volt)
3.Operation manual x 1
4.Hard carry case x 1
Optional accessory: a) RS232 software CD-R.
b) D-sub connector.
14
GENERAL SPECIFICATION
SPECIFICATIONS
Resolution
Accuracy
Airflow Range
80-5900 ft/min
0.4-30 m/sec
1
0.01
o
0.1
Temperature
+14 F to 122 F 0.1
Battery Life 100 Hours
(2% of reading
+0.2 m/s)
Display Type LCD
Display Size 37mm x 42mm(1-1/4" x 1- 5/8")
Max Reading 9999
Dimensions 183mm(L)x76mm(W)x45mm(D)
Fan Diameter 70mm(2-7/8")
RS232 OUTPUT FORMAT TXXX.XF, VXXXXFTM
TXXX.XC, VXXXXMPS
AUTO POWER OFF Approx. 20 minutes
DATA HOLD
RS232 OUTPUT:
The meter can link with personal computer to capture on-line datas
,display air velocity records with real-time output, you can retrieve file , save the datas for operating data analysis, records statistic ,multi-files display in the screen,
....versatile functions for your choice.
15
Connection procedures:
1.Plug the optional accessory RS232
cable onto the DC jack port ( at the
right side of the meter)
2.Instert the D-sub 9P type connector
onto computer's Com.1 or 2 port or....
3.Start to set up RS232 software by
inserting the CD-ROM or Floppy
diskette.
4.When installing the RS232 software
,please follow the operation manual
procedure in the software package.
WARRANTY
The meter is warranted to be free from defects in material and workmanship for a period of one year from the date of purchase. This warranty covers normal operation and does not cover battery , misuse , abuse , alteration , tampering , neglect , improper maintenance , or damage resulting from leaking batteries .
Proof of purchase is required for warranty repairs . Warranty is void if the meter has been opened .
16
RETURN AUTHORIZATION
Authorization must be obtained from the supplier before returning items for any reason . When requiring a RA (Return
Authorization) , please include data regarding the defective reason, the meters are to be returned along with good packing to prevent any damage in shipment and insured against possible damage or loss .
CE CERTIFICATION
The meter conforms to the following
standards:
* EN 50081-1/1992: EN 55022
* EN 50082-1/1997: (EN 61000-4-2/-3/-8
,ENV 50204)
, the meter complies with the essential protection requirements of Council
Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility.
17
Accuracy, the Zenith of
Measuring / Testing Instruments !
Hygrometer/Psychrometer
Thermometer
Anemometer
Sound Level Meter
Air Flow meter
Infrared Thermometer
K type Thermometer
K.J.T. type Thermometer
K.J.T.R.S.E. type Thermometer pH Meter
Conductivity Meter
T.D.S. Meter
D.O. Meter
Saccharimeter
Manometer
Tacho Meter
Lux / Light Meter
Moisture Meter
Data logger
Temp./RH transmitter
Wireless Transmitter ..........
More products available !
2015.02.V02
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project