WIRING INSTRUCTIONS CORDLESS 28 V VACUUM CLEANER 58-01-1165 TITLE

WIRING INSTRUCTIONS CORDLESS 28 V VACUUM CLEANER 58-01-1165 TITLE
WIRING INSTRUCTIONS
TITLE
BULLETIN
CORDLESS 28 V VACUUM CLEANER
MILWAUKEE ELECTRIC TOOL CORP.
13135 WEST LISBON RD. BROOKFIELD, WIS.
DATE
58-01-1165
Feb. 2008
1
2
1
5
4
3
2
6
2
1
NOTE:
All lead lengths are before stripping.
All field leads are to be measured from
and perpendicular to laminations.
All leads must be held to ± 1/8".
Strip wire per ES 13-11.
Crimp terminals per ES 13-15.
See terminal drawings for crimp heights.
WIRING SPECIFICATIONS
Wire
No.
1
2
3
4
5
6
Wire
Color
Red
Black
Red
Black
Red
Red
Origin or
Part No. Gauge Length
Terminals, Connectors and End Wire Preparation
PCB Board
14
14.2"
Route to 28 V Connector Block (+)
PCB Board
14
14.2"
Route to 28 V Connector Block (-)
PCB Board
14
9.8"
Route to Motor (+)
PCB Board
14
9.8"
Route to Motor (-)
PCB Board
14
11.4"
Route to Switch (3)
PCB Board
14
11.4"
Route to Switch (2)
BULK LEAD WIRE - BULLETIN 58-01-0003
TERMINAL DESCRIPTION
Code
Part No.
Qty.
CONNECTOR DESCRIPTION
Code
Part No.
Qty.
Drwg.1