Daikin Altherma EGSQH10S18AA9W ground source heat pump User reference guide
The Daikin Altherma EGSQH10S18AA9W is a ground source heat pump that can heat your home and provide domestic hot water. It features a user-friendly interface that allows you to control the temperature and other settings. The unit is designed to be energy-efficient and environmentally friendly.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
User reference guide
Daikin Altherma ground source heat pump
EGSQH10S18AA9W
User reference guide
Daikin Altherma ground source heat pump
English
Table of contents
Table of contents
1 General safety precautions
2
About the documentation ..........................................................
Meaning of warnings and symbols..............................
For the user ...............................................................................
2 About this document 3
3 About the system
3
Components in a typical system layout .....................................
4 Operation
4
Overview: Operation..................................................................
The user interface at a glance...................................................
Buttons........................................................................
Status icons ................................................................
Basic usage ...............................................................................
Using home pages ......................................................
Using the menu structure............................................
Turning ON/OFF controls............................................
Space heating control................................................................
About space heating control .......................................
Setting the space operation mode ..............................
Determining which temperature control you are using 6
Domestic hot water control ........................................................
About domestic hot water control................................ 10
Reheat mode .............................................................. 11
Scheduled mode ......................................................... 11
Scheduled + reheat mode........................................... 12
Using the DHW tank temperature home page ............ 12
Using the DHW tank booster mode ............................ 13
Advanced usage........................................................................
About changing the user permission level .................. 13
Using quiet mode ........................................................ 13
Using holiday mode .................................................... 13
Reading out information.............................................. 14
Configuring user profile and home pages ................... 15 4.6.6
Locking and unlocking buttons and functions ............. 15
Preset values and schedules ....................................................
Using preset values .................................................... 15
Using and programming schedules ............................ 16
Schedules: Example ................................................... 16
Predefined schedules: Leaving water temperature
(additional) .................................................................. 17
Predefined schedules: DHW tank temperature........... 17
Weather dependent operation...................................................
To set the weather dependent settings....................... 17
User reference guide
2
Menu structure: Overview user settings ..................................... 19
Installer settings: Tables to be filled in by installer ..................... 20
Quick wizard ................................................................ 20
Space heating control .................................................. 20
Domestic hot water control [A.4] .................................. 20
Contact/helpdesk number [6.3.2] ................................. 20
5 Energy saving tips 20
6 Maintenance and service
21
Overview: Maintenance and service .......................................... 21
To find the contact/helpdesk number ......................................... 21
7 Troubleshooting
21
Overview: Troubleshooting......................................................... 21
To check the error history........................................................... 21
To check the warning history...................................................... 21
Symptom: You are feeling too cold (hot) in your living room ...... 21
Symptom: The water at the tap is too cold ................................. 21
Symptom: Heat pump failure ...................................................... 21
8 Relocation
22
Overview: Relocation ................................................................. 22
9 Disposal
22
Overview: Disposal..................................................................... 22
10 Glossary 22
1 General safety precautions
1.1
About the documentation
▪ The original documentation is written in English. All other languages are translations.
▪ The precautions described in this document cover very important topics, follow them carefully.
▪ The installation of the system, and all activities described in the installation manual and the installer reference guide must be performed by an authorized installer.
1.1.1
Meaning of warnings and symbols
DANGER
Indicates a situation that results in death or serious injury.
DANGER: RISK OF ELECTROCUTION
Indicates a situation that could result in electrocution.
DANGER: RISK OF BURNING
Indicates a situation that could result in burning because of extreme hot or cold temperatures.
WARNING
Indicates a situation that could result in death or serious injury.
CAUTION
Indicates a situation that could result in minor or moderate injury.
NOTICE
Indicates a situation that could result in equipment or property damage.
INFORMATION
Indicates useful tips or additional information.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
1.2
For the user
▪ If you are not sure how to operate the unit, contact your installer.
▪ This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
WARNING
To prevent electric shocks or fire:
▪ Do NOT rinse the unit.
▪ Do NOT operate the unit with wet hands.
▪ Do NOT place any objects containing water on the unit.
NOTICE
▪ Do NOT place any objects or equipment on top of the unit.
▪ Do NOT sit, climb or stand on the unit.
▪ Units are marked with the following symbol:
2 About this document
Documentation set
This document is part of a documentation set. The complete set consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before operating your system
▪ Format: Paper (in the box of the indoor unit)
▪ Operation manual:
▪ Quick guide for basic usage
▪ Format: Paper (in the box of the indoor unit)
▪ User reference guide:
▪ Detailed step-by-step instructions and background information for basic and advanced usage
▪ Format: Digital files on http://www.daikineurope.com/supportand-manuals/product-information/
Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer.
The original documentation is written in English. All other languages are translations.
Available screens
Depending on your system layout and installer configuration, not all screens in this document may be available on your user interface.
Breadcrumbs
7.4.1.1
Comfort (heating)
Eco (heating)
Room temperature 1
20.0°C >
18.0°C >
This means that electrical and electronic products may not be mixed with unsorted household waste. Do NOT try to dismantle the system yourself: the dismantling of the system, treatment of the refrigerant, of oil and of other parts must be done by an authorized installer and must comply with applicable legislation.
Units must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. For more information, contact your installer or local authority.
▪ Batteries are marked with the following symbol:
Select Scroll
Breadcrumbs help you to locate where you are in the menu structure of the user interface. This document also mentions these breadcrumbs.
Example: Go to [7.4.1.1]: > User settings > Preset values >
Room temperature > Comfort (heating)
This means that the batteries may not be mixed with unsorted household waste. If a chemical symbol is printed beneath the symbol, this chemical symbol means that the battery contains a heavy metal above a certain concentration.
Possible chemical symbols are: Pb: lead (>0.004%).
Waste batteries must be treated at a specialized treatment facility for reuse. By ensuring waste batteries are disposed of correctly, you will help to prevent potential negative consequences for the environment and human health.
3 About the system
Depending on the system layout, the system can:
▪ Heat up a space
▪ Produce domestic hot water
2 About this document
Thank you for purchasing this product. Please:
▪ Read the documentation carefully before operating the user interface to ensure the best possible performance.
▪ Request the installer to inform you about the settings that he used to configure your system. Check if he has filled in the installer settings tables. If not, request him to do so.
▪ Keep the documentation for future reference.
Target audience
End users
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
3
4 Operation
3.1
Components in a typical system layout
C g
B A d b c e f a
Part
Advanced usage
Description
Information about:
▪ Quiet mode
▪ Holiday mode
▪ Reading out information
Preset values and schedules
▪ Date, time, units of measurement, contrast and backlight
▪ User profile and home pages
▪ Locking and unlocking buttons and functions
▪ How to use preset values
▪ How to select and program schedules
Menu structure
▪ Overview of predefined schedules
Overview of menu structure
Installer settings table Overview of installer settings
4.2
The user interface at a glance
4.2.1
Buttons
A
Main zone. Example: Living room.
B
Additional zone. Example: Bedroom.
C
Technical room. Example: Garage.
a
Brine loop
b
Indoor unit heat pump
c
Domestic hot water (DHW) tank
d
User interface at the indoor unit
e
User interface in the living room, used as room thermostat
f
Underfloor heating
g
Heat pump convectors or fan coil units
4 Operation
4.1
Overview: Operation
You can operate the system via the user interface. This part describes how to use the user interface:
Part
At a glance
Basic usage
Description
▪ Buttons
▪ Status icons
Information about:
▪ Home pages, where you can read out and change settings that are meant for daily usage
▪ Menu structure, where you can read out and configure settings that are NOT meant for daily usage
▪ ON/OFF controls
Space heating control How to control space heating:
Domestic hot water control
▪ Setting the space operation mode
▪ Controlling the temperature
How to control domestic hot water:
▪ Reheat mode
▪ Scheduled mode
▪ Scheduled + reheat mode
b a c d a b c d e f f e
HOME PAGES
▪ Switches between home pages (when you are on a home page).
▪ Goes to the default home page (when you are in the menu structure).
MALFUNCTION INFORMATION
If a malfunction occurs, is displayed on the home pages.
Press to display more information about the malfunction.
ON/OFF
Turns ON or OFF one of the controls (room temperature, leaving water temperature, DHW tank temperature).
MENU STRUCTURE/BACK
▪ Opens the menu structure (when you are on a home page).
▪ Goes up a level (when you are navigating through the menu structure).
▪ Goes back 1 step (example: when you are programming a schedule in the menu structure).
NAVIGATING/CHANGING SETTINGS
▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.
OK
User reference guide
4
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches between displaying actual and desired values, or between displaying actual and offset values (if applicable) on the home pages.
▪ Goes to the next step (when you are programming a schedule in the menu structure).
▪ Enables you to activate or deactivate button lock if pressed for more than 5 seconds on a home page.
▪ Enables you to activate or deactivate a function lock if pressed for more than 5 seconds in the main menu of the menu structure.
INFORMATION
If you press or while changing settings, the changes will NOT be applied.
4.2.2
Status icons
Icon
Description
Space operation mode = Heating.
Not available.
Unit is operating.
Desired room temperature = preset value (Comfort; daytime).
Desired room temperature = preset value (Eco; nighttime).
▪ On the room temperature home page: Desired room temperature = according to the selected schedule.
▪ On the DHW tank temperature home page:
DHW tank mode = Scheduled mode.
DHW tank mode = Reheat mode.
DHW tank mode = Scheduled + reheat mode.
Domestic hot water operation.
Actual temperature.
Desired temperature.
At the next scheduled action, the desired temperature will increase.
At the next scheduled action, the desired temperature will NOT change.
At the next scheduled action, the desired temperature will decrease.
The preset value (Comfort or Eco) or scheduled value is temporarily overruled.
The DHW tank booster mode is active or ready to be activated.
Quiet mode is active.
Holiday mode is active or ready to be activated.
Button lock mode and/or function lock mode is active.
An external heat source is active. Example: Gas burner.
The disinfection mode is active.
A malfunction occured. Press to display more information about the malfunction.
Weather-dependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
Icon Description
Emergency operation is active.
INFORMATION
Quiet mode is NOT applicable for this unit.
4 Operation
4.3
Basic usage
4.3.1
Using home pages
About home pages
You can use the home pages to read out and change settings that are meant for daily usage. What you can see and do on the home pages is described where applicable. Depending on your system layout, the following home pages may be possible:
▪ Room temperature (Room)
▪ Main leaving water temperature (LWT main)
▪ Additional leaving water temperature (LWT add)
▪ DHW tank temperature (Tank)
To go to a home page
1
Press .
Result: One of the home pages is displayed.
2
Press again to display the next home page (if any).
4.3.2
Using the menu structure
About the menu structure
You can use the menu structure to read out and configure settings that are NOT meant for daily usage. What you can see and do in the menu structure is described where applicable. For an overview of the menu structure, see
"4.9 Menu structure: Overview user settings" on page 19
.
To go to the menu structure
1
From a home page, press .
Result: The menu structure is displayed.
Set time/date
Holiday
Select schedules
Information
1
>
>
Select Scroll
To navigate in the menu structure
Use , , , , and .
4.3.3
Turning ON/OFF controls
About turning ON/OFF controls
Before you can control…
Room temperature
Main (+ additional) leaving water temperature
You have to turn ON…
Room temperature control
(Room)
Main (+ additional) leaving water temperature control (LWT main and LWT add)
DHW tank temperature
Main and additional leaving water temperature control are always turned ON or OFF together.
Domestic hot water control
(Tank)
User reference guide
5
4 Operation
If you turn ON…
Room temperature control
Main (+ additional) leaving water temperature control
Then…
Main (+ additional) leaving water temperature control is automatically turned ON.
Room temperature control is
NOT automatically turned ON.
If you turn OFF…
Room temperature control
Main (+ additional) leaving water temperature control
Then…
Main (+ additional) leaving water temperature control is NOT automatically turned OFF.
Room temperature control is automatically turned OFF.
To check if a control is turned ON or OFF
1
Go to the home page of the control. Example: Room temperature home page (Room).
2
Check if the LED is ON or OFF. Note: If the control is turned
OFF, OFF is also displayed on the screen.
To turn ON or OFF the room temperature control
1
Go to the room temperature home page (Room).
2
Press .
To turn ON or OFF the leaving water temperature (main + additional) control
1
Go to one of the following the home pages:
▪ Main leaving water temperature home page (LWT main)
▪ Additional leaving water temperature home page (LWT add)
2
Press .
To turn ON or OFF the domestic hot water control
1
Go to the DHW tank temperature home page (Tank).
2
Press .
4.4
Space heating control
4.4.1
About space heating control
Controlling space heating typically consists of the following stages:
1 Setting the space operation mode
2 Controlling the temperature
4.4.2
Setting the space operation mode
About space operation modes
The heat pump is a heating only model. The system can heat up a space, but NOT cool down a space.
4.4.3
Determining which temperature control you are using
To determine which temperature control you are using (method 1)
Check the installer settings table filled in by the installer.
To determine which temperature control you are using (method 2)
If you have 2 user interfaces, perform the following procedure on the user interface at the indoor unit.
Prerequisite: You switched the permission level to Advanced end user.
1
Press multiple times to switch between home pages, and check if the additional leaving water temperature home page
(LWT add) is available:
If …
Available
NOT available
Then you have…
A main zone and an additional zone
Only a main zone
Typical additional leaving water temperature home page:
User profile = Basic User profile = Detailed
45°C
Mon 15:20
LWT add
45°C
Desired temperature
Mon
15:20
LWT add
Mon 17:30
Desired temperature
2
Check the following:
If…
Room temperature is listed under:
Then the temperature control is…
Main zone Additional zone
(if any)
Room thermostat control.
External room thermostat control.
[6.1]: > Information
> Sensor information
Thermostat main A is listed under:
Go to next step to check if leaving water set point and room temperature set point are linked.
External room thermostat control.
[6.5]: > Information
> Actuators
Else Leaving water temperature control.
3
Only for room thermostat control: Go to the main leaving water temperature home page (LWT main) and check the following:
Is displayed
Yes
next to the set point?
Then leaving water set point and room temperature set point are…
No
NOT linked.
You can set the leaving water set point on the home page.
Linked by their preset values. You can set the preset values in the menu structure.
4.4.4
Room thermostat control - About room thermostat control
Room thermostat control means that you control the following:
▪ Room temperature of the main zone
▪ Leaving water temperature of the main zone
Room temperature of the main zone
To control the room temperature of the main zone, you can do the following:
You can… Location
Read out the actual and desired room
temperature.
Temporarily overrule the room temperature
schedule.
Room temperature home page
User reference guide
6
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
You can…
Change the mode from scheduled to preset value.
Location
Room temperature home page if user profile = Detailed
If you do this, you also have to define (in the menu structure):
▪ Preset values
▪ Overrule period (Temperature lock)
Select which room temperature schedule you want to use.
Program schedules.
Define preset values that are used by the room temperature schedule, and when you change the mode from scheduled to preset value.
Menu structure
See also:
▪
"4.4.5 Room thermostat control - Using the room temperature home page" on page 7
▪
"To set the overrule period" on page 8
▪
"4.7 Preset values and schedules" on page 15
Leaving water temperature of the main zone
To control the leaving water temperature of the main zone, you can do the following:
You can…
Read out the desired leaving water
temperature.
Adjust the leaving water temperature.
Location
Leaving water temperature home page (main)
Condition: Leaving water set point is NOT linked with the room temperature set point.
Only change this if the desired room temperature cannot be reached.
Define preset values.
Condition: Leaving water set point is linked with the room temperature set point.
Menu structure
Only change this if the desired room temperature cannot be reached.
See also:
▪
"4.4.6 Room thermostat control - Using the leaving water temperature home pages" on page 9
▪
"4.7 Preset values and schedules" on page 15
4.4.5
Room thermostat control - Using the room temperature home page
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a basic or a detailed home page. To set the user profile, refer to
"4.6.6 Configuring user profile and home pages" on page 15
.
4 Operation
User profile = Basic
Mon 15:20
Room
20.0°C
Actual temperature
User profile = Detailed
20.0°C
Actual temperature
Mon 15:20
Room
Scheduled
Tue 17:30
To read out the actual and desired room temperature
1
Go to the room temperature home page (Room).
Result: You can read out the actual temperature.
20.0°C
Actual temperature
2
Press .
Result: You can read out the desired temperature.
22.0°C
Desired temperature
To temporarily overrule the room temperature schedule
1
Go to the room temperature home page (Room).
2
Use or to adjust the temperature.
To change the mode from scheduled to preset value
Prerequisite: User profile = Detailed.
1
Go to the room temperature home page (Room).
2
Press or to select a preset value ( or ).
Result: The mode will return to Scheduled according to the overrule period.
Example: Temporarily overruling the schedule
AND changing the mode to preset value
You have configured the following settings:
Settings Description
Preset values Comfort (heating) =
20°C
Desired temperature when you are at home.
Eco (heating) = 18°C Desired temperature:
▪ When you are away
▪ During the night
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
7
4 Operation
Schedule
Settings
07:00 Comfort
09:00 Eco
17:00 Comfort
19:00 21°C
23:00 Eco
Overrule period
(Temperature lock)
2 hours
User reference guide
8
Description
You are at home.
Desired temperature = preset value (Comfort
(heating)).
You are away.
Desired temperature = preset value (Eco
(heating)).
You are at home.
Desired temperature = preset value (Comfort
(heating)).
You are at home and want it to be a little warmer.
Desired temperature = custom temperature.
Desired temperature = preset value (Eco
(heating)).
If you temporarily overrule the schedule by a preset value, after 2 hours the schedule will be used again.
If user profile = Basic, then you can temporarily overrule the room temperature schedule by pressing or .
Situation
18.0°C
15:20
19.0°C
15:20
Description
15:20 => Scheduled temperature
= preset value (Eco (heating)) =
18°C.
You temporarily overrule the schedule.
Desired temperature = custom temperature = 19°C.
At the next scheduled action
(17:00), the schedule will be used again.
If user profile = Detailed, then you can:
▪ Temporarily overrule the room temperature schedule by pressing or (same as if user profile = Basic)
▪ Change the mode from scheduled to a preset value by pressing
or
Situation
18.0°C
Scheduled
Mon 17:00
15:20
Description
Room temperature schedule is used.
15:20 => Desired temperature = preset value (Eco (heating)) =
18°C.
The next scheduled action is at
17:00 and the desired temperature will then increase.
Scheduled
Mon 17:00
Scheduled
Mon 17:00
Scheduled
Mon 17:20
Situation
18.0°C
18.0°C
20.0°C
19.0°C
Scheduled
Mon 17:00
20.0°C
Scheduled
Mon 17:20
21.0°C
Scheduled
Mon 17:20
Description
You temporarily overrule the schedule.
Desired temperature = custom temperature = 19°C.
At the next scheduled action
(17:00), the schedule will be used again.
You change the mode from scheduled to preset value
(Comfort (heating)).
Desired temperature = preset value (Comfort (heating)) = 20°C.
After 2 hours, the schedule will be used again (17:20 => 20°C).
Before you have changed the
mode from scheduled to preset value, and now you temporarily
overrule the preset value.
Desired temperature = custom temperature = 21°C.
After 2 hours, the schedule will be used again (17:20 => 20°C).
To set the overrule period
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [7.2]: > User settings > Temperature lock.
2
Select a value and press :
▪ Permanent
▪ hours (2, 4, 6, 8)
Usage example: You have a party
If you are in the following situation:
▪ You are using the following room temperature schedule:
▪ 17:00 preset value (Comfort) = 20°C
▪ 23:00 preset value (Eco) = 18°C
▪ Tonight you have a party and you want to use the preset value
(Comfort) until 02:00.
Then you can do the following:
1
Set the overrule period (Temperature lock) to 6 hours.
2
At 20:00, go to the room temperature home page (Room).
3
Press to select .
Result: The preset value (Comfort) will be used until 02:00.
After that, the schedule will be used again.
Usage example: You go away for a couple of hours
If you are in the following situation:
▪ You are using the following room temperature schedule:
▪ 08:00 preset value (Comfort) = 20°C
▪ 23:00 preset value (Eco) = 18°C
▪ At 14:00, you go away for 3 hours.
Then you can do the following:
1
Set the overrule period (Temperature lock) to 2 hours.
2
Go to the room temperature home page (Room).
3
Press to select .
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
Result: For the next 2 hours, the room will NOT be heated to the scheduled 20°C, but to the preset value (Eco = 18°C). After the
2 hours, the room will heat up again to the scheduled 20°C.
Advantage:
You save energy because you do NOT heat the room unnecessary, and by the time you come home the room is warm again.
4.4.6
Room thermostat control - Using the leaving water temperature home pages
INFORMATION
The leaving water is the water that is sent to the heat emitters. The desired leaving water temperature is set by your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving water temperature than radiators and heat pump convectors and/or fan coil units. You only have to adjust leaving water temperature settings in case of problems.
Typical leaving water temperature home pages
Main zone:
User profile = Detailed User profile = Basic
Mon
15:20
LWT main
35°C
35°C
Desired temperature
Mon 15:20
LWT main
Mon 17:30
Desired temperature
Additional zone:
User profile = Basic
Mon 15:20
LWT add
45°C
Desired temperature
User profile = Detailed
45°C
Desired temperature
Mon 15:20
LWT add
Mon 17:30
To read out the desired leaving water temperature
(main + additional)
Go to the leaving water temperature home page (LWT main or LWT add).
To adjust/overrule the leaving water temperature
(NOT linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to the room temperature setpoint, see
"4.4.3 Determining which temperature control you are using" on page 6 .
To adjust the leaving water temperature (main)
1
Go to the main leaving water temperature home page (LWT main).
2
Press or to adjust. Example:
35°C 37°C
INFORMATION
In case of weather dependency, an offset value can be modified.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
4 Operation
To adjust the leaving water temperature (additional)
1
Go to the additional leaving water temperature home page
(LWT add).
2
Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
To adjust/overrule the leaving water temperature
(linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to the room temperature setpoint, see
"4.4.3 Determining which temperature control you are using" on page 6
.
To set leaving water temperature preset values (main)
INFORMATION
You cannot adjust/overrule the leaving water temperature
(main) for room thermostat control with linked leaving water temperatures. However if necessary, you can adjust the desired leaving water temperature (main) by adjusting preset values.
INFORMATION
Adjusting the leaving water temperature is permanent unless the leaving water temperature is according to a schedule. In that case the overruling is valid until the next scheduled action.
1
Go to [7.4.2]: > User settings > Preset values > LWT main.
2
Set the Preset values according to following graph.
Example: Room thermostat comfort temperature will correspond with leaving water comfort temperature.
Tl
Tr
▪ T r
: Room temperature
▪ T l
: Leaving water temperature
3
Press or to adjust/overrule.
To adjust the leaving water temperature (additional)
1
Go to the additional leaving water temperature home page
(LWT add).
2
Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.4.7
Leaving water temperature control -
About leaving water temperature control
Leaving water temperature control means that you only control the leaving water temperature. To control the leaving water temperature, you can do the following:
User reference guide
9
4 Operation
You can… Location
Read out the desired leaving water
temperature (main + additional).
▪ Adjust/overrule the leaving water
temperature (main).
Leaving water temperature home pages (main + additional)
▪ Adjust the leaving water temperature
(additional).
Select which leaving water temperature
schedule (main + additional) you want to use.
Program leaving water temperature
schedule (main + additional).
Define preset values that are used by the leaving water temperature schedule (main).
Menu structure
See also:
▪
"4.4.6 Room thermostat control - Using the leaving water temperature home pages" on page 9
▪
"4.7 Preset values and schedules" on page 15
4.4.8
Leaving water temperature control - Using leaving water temperature control according to a schedule
To set leaving water temperature preset values
(main)
INFORMATION
Adjusting the leaving water temperature is permanent unless the leaving water temperature is according to a schedule. In that case the overruling is valid until the next scheduled action.
1
Go to [7.4.2]: > User settings > Preset values > LWT main.
2
Press or to overrule. Example:
35°C 37°C
To adjust the leaving water temperature
(additional)
1
Go to the additional leaving water temperature home page
(LWT add).
2
Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.4.9
Leaving water temperature control - Using leaving water temperature control NOT according to a schedule
To adjust the leaving water temperature (main)
1
Go to the main leaving water temperature home page (LWT main).
2
Press or to adjust. Example:
35°C 37°C
To adjust the leaving water temperature
(additional)
1
Go to the additional leaving water temperature home page
(LWT add).
User reference guide
10
2
Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.4.10
External room thermostat control - About external room thermostat control
External room thermostat control means that you control the following:
▪ Room temperature on the external thermostat control
▪ Leaving water temperature on the user interface (Daikin)
To control the leaving water temperature, you can do the following:
You can…
Read out the desired leaving water
temperature.
Adjust the desired leaving water
temperature.
Location
Leaving water temperature home pages (main + additional)
Only change this if the desired room temperature cannot be reached.
See also:
"4.4.6 Room thermostat control - Using the leaving water temperature home pages" on page 9
4.4.11
External room thermostat control - Using external room thermostat control
To adjust the leaving water temperature (main)
1
Go to the main leaving water temperature home page (LWT main).
2
Press or to adjust. Example:
35°C 37°C
To adjust the leaving water temperature
(additional)
1
Go to the additional leaving water temperature home page
(LWT add).
2
Press or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be modified.
4.5
Domestic hot water control
4.5.1
About domestic hot water control
Depending on the DHW tank mode (installer setting), you use a different domestic hot water control:
▪ Reheat mode
▪ Scheduled mode
▪ Scheduled + reheat mode
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
CAUTION
The backup heater permission schedule is used to restrict or allow backup heater operation based on a weekly program. Advice: In order to avoid unsuccessful disinfection function, at least allow the backup heater (by the weekly program) for minimum 4 hours starting from the scheduled start-up of disinfection. If the backup heater is restricted during disinfection, this function will NOT be successful and the applicable warning AH will be generated.
INFORMATION
In case of error code AH and no interruption of the disinfection function occurred due to domestic hot water tapping, following actions are recommended:
▪ When the Domestic hot water > Type > Reheat or
Reheat + sched. is selected, it is recommended to program the start-up of the disinfection function at least
4 hours later than the last expected large hot water tapping. This start-up can be set by installer settings
(disinfection function).
▪ When the Domestic hot water > Type > Scheduled only is selected, it is recommended to program a Storage eco 3 hours before the scheduled start-up of the disinfection function to preheat the tank.
To determine which DHW tank mode you are using (method 1)
Check the installer settings table filled in by the installer.
To determine which DHW tank mode you are using (method 2)
Prerequisite: User profile = Detailed.
1
Go to the DHW tank temperature home page (Tank).
2
Check which icons are displayed:
If… is displayed
Then the DHW tank mode =…
Reheat mode
Scheduled mode
Scheduled + reheat mode
4.5.2
Reheat mode
In reheat mode ( ),the DHW tank continuously heats up to the temperature shown on the DHW tank temperature home page
(example: 50°C).
Tt
1 3
60°C
50°C
40°C
2 4
15°C
00:00 07:00
T t
DHW tank temperature
t
Time
14:00 21:00
t
INFORMATION
When the DHW tank mode is reheat, the risk for capacity shortage and comfort problem is significant. In case of frequent reheat operation, space heating function is regularly interrupted.
In reheat mode, you can do the following:
4 Operation
You can…
Read out the desired reheat temperature.
Adjust the reheat temperature.
Location
DHW tank temperature home page
Condition: is displayed on the DHW tank temperature home page.
Activate the DHW tank booster mode.
(Only for field supplied domestic hot water pump for secondary return)
Program a domestic hot water pump schedule
to determine when to turn ON and OFF the pump.
Menu structure
When turned ON, the pump runs and makes sure hot water is instantly available at the tap. To save energy, only turn ON the pump during periods of the day when instant hot water is necessary.
See also:
▪
"4.5.5 Using the DHW tank temperature home page" on page 12
▪
"4.5.6 Using the DHW tank booster mode" on page 13
▪
"4.7 Preset values and schedules" on page 15
4.5.3
Scheduled mode
In scheduled mode ( ), the DHW tank produces hot water corresponding to a schedule. The best time to allow the tank to produce hot water is at night, because the space heating demand is lower.
Example:
Tt
60°C
50°C
40°C
1
2
3
4
5
15°C
00:00 07:00
T t
DHW tank temperature
t
Time
14:00 21:00
t
▪ Initially, the DHW tank temperature is the same as the temperature of the domestic water entering the DHW tank
(example: 15°C).
▪ At 00:00 the DHW tank is programmed to heat up the water to a preset value (example: Storage comfort = 60°C).
▪ During the morning, you consume hot water and the DHW tank temperature decreases.
▪ At 14:00 the DHW tank is programmed to heat up the water to a preset value (example: Storage eco = 50°C). Hot water is available again.
▪ During the afternoon and evening, you consume hot water again and the DHW tank temperature decreases again.
▪ At 00:00 the next day, the cycle repeats.
In scheduled mode, you can do the following:
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
11
4 Operation
You can…
Read out the active or next scheduled desired
temperature.
Overrule the active or next scheduled desired
temperature.
Location
DHW tank temperature home page
Condition: is displayed on the DHW tank temperature home page.
Activate the DHW tank booster mode.
Select a DHW tank temperature schedule.
Program a DHW tank temperature schedule.
Define preset values that are used by the
DHW tank temperature schedule.
(Only for field supplied domestic hot water pump for secondary return)
Program a domestic hot water pump schedule
to determine when to turn ON and OFF the pump.
Menu structure
When turned ON, the pump runs and makes sure hot water is instantly available at the tap. To save energy, only turn ON the pump during periods of the day when instant hot water is necessary.
See also:
▪
"4.5.5 Using the DHW tank temperature home page" on page 12
▪
"4.5.6 Using the DHW tank booster mode" on page 13
▪
"4.7 Preset values and schedules" on page 15
4.5.4
Scheduled + reheat mode
In scheduled + reheat mode ( ), the domestic hot water control is the same as in scheduled mode. However, when the DHW tank temperature drops below a preset value (=reheat tank temperature – hysteresis value; example: 35°C), the DHW tank heats up until it reaches the reheat set point (example: 45°C). This ensures that a minimum amount of hot water is available at all times.
Example:
Tt
60°C
45°C
35°C
15°C
1
2
3
00:00 07:00 14:00 21:00
T t
DHW tank temperature
t
Time
60°C
Storage comfort
50°C
Storage eco
45°C
Reheat
35°C
Reheat tank temperature – hysteresis value
4
5
t
In scheduled + reheat mode, you can do the following:
You can…
Do the same things as in scheduled mode.
Adjust the preset value (Reheat).
Location
—
Menu structure
See also:
▪
"4.5.3 Scheduled mode" on page 11
▪
"4.7 Preset values and schedules" on page 15
User reference guide
12
4.5.5
Using the DHW tank temperature home page
Typical DHW tank temperature home pages
Depending on the user profile, the user interface gives you either a basic or a detailed home page. The examples in the illustrations below are in DHW tank mode = Scheduled.
User profile = Basic
Mon 15:20
Tank
60°C
Storage comfort
User profile = Detailed
60°C
Storage comfort
Tue 00:00
Mon 15:20
Tank
To read out and adjust the desired reheat temperature (in scheduled and reheat mode)
1
Go to [7.4.3.3]: > User settings > Preset values > Tank temperature > Reheat.
Result: You can read out the desired reheat temperature.
2
Press or to adjust.
Tt
Tt a b
To read out and overrule the active or next scheduled desired temperature (in scheduled mode or scheduled + reheat mode)
1
Go to the DHW tank temperature home page (Tank).
Result:
60°C
is displayed.
A1
A2
B1
B2
T t
DHW tank temperature
t
Time
During period… You can read out…
The next scheduled action (a)
The active action (a)
The next scheduled action (b)
The active action (b)
t
2
Press or to overrule. Note: If the desired temperature is weather dependent, you cannot change it on the home page.
Usage example: You need more hot water than scheduled
If you are in the following situation:
▪ Current time = 10:30
▪ Next scheduled action of the DHW tank = Heat up to the preset value (Eco; example: 55°C and sufficient for 2 persons) at 14:00
▪ This evening you need hot water for 3 persons
Then you can do the following:
1
Go to the DHW tank temperature home page (Tank).
2
Overrule the next scheduled action by changing from 55°C to
60°C.
Advantages:
▪ You will have sufficient hot water (= comfortable).
▪ You do NOT have to change the schedule (= easy).
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
▪ You do NOT have to activate the DHW tank booster mode
(= energy saving).
4.5.6
Using the DHW tank booster mode
About the DHW tank booster mode
You can use the DHW tank booster mode to immediately start heating up the water to the preset value (Storage comfort). However, this consumes extra energy.
To check if the DHW tank booster mode is active
1
Go to the DHW tank temperature home page (Tank).
2
Check the following:
▪ In user profile = Basic: If is displayed, the DHW tank booster mode is active.
▪ In user profile = Detailed: If is selected, the DHW tank booster mode is active.
To activate the DHW tank booster mode (user profile = Basic)
1
Go to the DHW tank temperature home page (Tank).
2
Press for more than 5 seconds.
To activate the DHW tank booster mode (user profile = Detailed)
1
Go to the DHW tank temperature home page (Tank).
2
Press to select .
Usage example: You immediately need more hot water
If you are in the following situation:
▪ You already consumed most of your hot water.
▪ You cannot wait for the next scheduled action to heat up the
DHW tank.
Then you can activate the DHW tank booster mode.
Advantage: The DHW tank immediately starts heating up the water to the preset value (Storage comfort).
4.6
Advanced usage
4.6.1
About changing the user permission level
The amount of information you can read out in the menu structure depends on your user permission level:
▪ End user (= default)
▪ Adv. end user: You can read out more information.
To set the user permission level to Advanced end user
1
Go to the main menu or any of its submenus: .
2
Press for more than 4 seconds.
Result: The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu title.
The user permission level will stay in Adv. end user until set otherwise.
To set the user permission level to End user
1
Press for more than 4 seconds.
Result: The user permission level switches to End user. The user interface will return to the default home screen.
4.6.2
Using quiet mode
INFORMATION
Quiet mode is NOT applicable for this unit.
4 Operation
4.6.3
Using holiday mode
About holiday mode
During your holiday, you can use the holiday mode to deviate from your normal schedules without having to change them. You can only use holiday mode if temperature control = room thermostat control.
See also
"4.4.3 Determining which temperature control you are using" on page 6 .
Using holiday mode typically consists of the following stages:
1 Configuring the holiday for one of the following situations:
Situation
You stay at home during your holiday
You go away during your holiday
Then…
You have to select a day: space heating will be according to the desired room temperature of the selected day.
You have to configure space heating settings.
▪ Space heating will be according to these settings.
▪ Domestic hot water operation can be turned ON or OFF. If you decide to turn it OFF, disinfection mode will remain active.
2 Activating the holiday mode.
▪ If you do NOT activate, the configured holiday settings will
NOT be used.
▪ If you activate:
Period
Before and after your holiday
During your holiday
Then…
Your normal schedules will be used.
The configured holiday settings will be used.
To check if holiday mode is activated and/or running
1
Press to go to one of the home pages.
2
Check the following:
If… is displayed
Mon 15:20
Then…
One of the following holiday modes is activated:
▪ Holiday mode (Away) is activated, but NOT running yet.
▪ Holiday mode (Home) is activated. You cannot see if the holiday mode is already running.
Holiday mode (Away) is activated and running.
Holiday
Until
Actual temp.
16 Feb
12.0°C
2013
To configure the holiday (when you stay at home)
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [2.2]: > Holiday > Holiday mode.
2
Select Home.
3
Configure the holiday mode settings (when you stay at home).
4
Activate the holiday mode.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
13
4 Operation
Possible holiday mode settings (when you stay at home)
Setting Description
From and Until First and last day of your holiday.
Use day schedule
Day schedule used during your holiday.
Example: Saturday
INFORMATION
Switch to Adv. end user if you want to change the Use day schedule setting.
To configure the holiday (when you go away)
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [2.2]: > Holiday > Holiday mode.
2
Select Leave.
3
Configure the holiday mode settings (when you go away).
4
Activate the holiday mode.
Possible holiday mode settings (when you go away)
Setting Description
From and Until First and last day of your holiday.
Operation mode Operation mode used during your holiday.
Heating
DHW
Set point used during your holiday when the unit is operating in heating mode.
Turn ON or OFF domestic hot water operation during your holiday.
INFORMATION
You can only change the From and Until settings in the
End user level. For changing the other settings, you have to switch to Adv. end user level.
To activate or deactivate the holiday mode
Prerequisite: You have configured the holiday.
1
Go to [2.1]: > Holiday > Holiday.
2
Do one of the following:
▪ To activate, select Yes and press .
▪ To deactivate, select No and press .
Usage example: You go away during the winter
If you are in the following situation:
▪ In 2 days, you go away for 2 weeks during the winter.
▪ You want to save energy, but prevent your house from freezing.
Then you can do the following:
Prerequisite: You switched the permission level to Advanced end user.
1
Configure the holiday. Go to [2]: > Holiday, and configure the following settings:
Setting
Holiday mode
From
Until
Operation mode
Heating
Value
Away
2 February 2014
16 February 2014
Heating
12°C
2
Activate the holiday mode.
▪ Go to [2.1]: > Holiday > Holiday.
▪ Select Yes and press .
Advantage:
▪ Before and after your holiday, your normal schedule will be used.
▪ During your holiday, you save energy and prevent your house from freezing.
Usage example: You come home during your holiday
If you are in the following situation:
▪ You configured and activated the holiday mode (Away).
▪ During your holiday, you come home for a few hours and want to use your normal schedule.
Then you can do the following:
1
Deactivate the holiday mode.
2
When you go away again, activate the holiday mode again.
Advantage:
You do NOT have to change your schedule or holiday configuration.
4.6.4
Reading out information
To read out information
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [6]: > Information.
Possible read-out information
In menu…
[6.1] Sensor information
[6.2] Energy metering
[6.3] Error handling
[6.4] User permission level
[6.5] Actuators
[6.6] Operation modes
[6.7] Running hours
[6.8] Version
You can read out…
Room, tank or DHW, outside, and leaving water temperature.
(If applicable)
Produced energy, consumed electricity, and consumed gas.
Error history and contact/ helpdesk number.
Current user permission level.
Status/mode of each actuator.
Example: Domestic hot water pump ON/OFF.
Current operation mode.
Example: Defrost/oil return mode.
Running hours of the system.
Version information about the system.
4.6.5
Configuring date, time, units of measurement, contrast and backlight
To configure time and date
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [1]: > Set time/date.
INFORMATION
Switch to Adv. end user to change daylight saving time and
12/24h notation.
To configure units of measurement
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [7.6]: > User settings > Unit of measurement.
User reference guide
14
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
Possible units of measurement settings
Decimal point
Setting
Temperature
Produced energy
Flow
Possible units of measurement
▪ Dot
▪ Comma
▪ °C
▪ °F
▪ kWh
▪ MBtu
▪ l/min
▪ GPM
To configure the contrast of the user interface
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [7.1.1]: > User settings > Display > Contrast.
To configure the backlit LCD time of the user interface
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [7.1.2]: > User settings > Display > Backlit LCD time.
4.6.6
Configuring user profile and home pages
To set a user profile
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [7.1.3]: > User settings > Display > User profile.
2
Select a user profile and press .
Possible user profiles
If user profile = Detailed, you can see and do more on the home pages.
User profile
Basic
Example
Mon
15:20
Room
20.0°C
Actual temperature
Detailed
20.0°C
Actual temperature
Scheduled
Tue 17:30
Mon 15:20
Room
To configure which home pages are made available to the end user
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [7.1.4]: > User settings > Display > Available home pages.
Result: The home pages that are possible for your system layout are listed.
2
Select a home page and press .
3
Do one of the following:
▪ To display the home page, select Yes and press .
▪ To hide the home page, select No and press .
4 Operation
4.6.7
Locking and unlocking buttons and functions
About locking and unlocking
You can use the following locking modes:
▪ Button lock: Locks all buttons to prevent children from changing settings.
▪ Function lock: Locks a specific function to prevent people from changing its settings.
Possible function locks
Room On/OFF
Lock
LWT On/OFF
Tank On/OFF
Temperature up/down
Holiday
User settings
If active, people cannot…
Turn ON or OFF the room temperature control.
Turn ON or OFF the leaving water temperature (main + additional) control.
Turn ON or OFF the domestic hot water control.
Adjust temperatures.
Use holiday mode.
Change settings in [7]: > User settings.
To check if locking is active
1
Press to go to one of the home pages.
2
If is displayed, button lock is active.
Note: If you are on a home page and try to use a function that is locked, is displayed for 1 second.
To activate or deactivate button lock
1
Press to go to one of the home pages.
2
Press for more than 5 seconds.
To activate or deactivate a function lock
1
Press to go to the menu structure.
2
Press for more than 5 seconds.
3
Select a function and press .
4
Select Lock or Unlock, and press .
4.7
Preset values and schedules
4.7.1
Using preset values
About preset values
You can define preset values for multiple controls. Preset values make it easy to use the same value in many places (schedules and room temperature home page ( and )). If you later want to change the value, you only have to do it in one place.
To define preset values
1
Go to [7.4]: > User settings > Preset values.
2
Select for which control you want to define a preset value.
Example: Room temperature.
3
Select a preset value and press . Example: Comfort
(heating).
4
Select a temperature and press .
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
15
4 Operation
Possible preset values
Control
Room temperature
Comfort
Eco
Preset value
LWT main
Tank temperature
Comfort
Eco
Storage comfort
Storage eco
Quiet level
Reheat
Where used
▪ Room schedules temperature
▪ Room temperature home page ( and ) if user profile = Detailed
Main leaving water temperature schedules
DHW tank temperature schedule if DHW tank mode is
▪ Scheduled
▪ Scheduled + reheat
DHW tank temperature schedule if DHW tank mode
= Scheduled + reheat
Not applicable.
4.7.2
Using and programming schedules
About schedules
Depending on your system layout and installer configuration, schedules (predefined and/or user‑defined) for multiple controls may be available.
You can:
▪ Select which schedules you currently want to use.
▪ Program your own schedules if the predefined schedules are not satisfactory. The actions you can program are control specific.
Possible actions per control
Control Possible actions
Room temperature Program when to heat up a space:
Main leaving water temperature
▪ Comfort (preset value)
▪ Eco (preset value)
Additional leaving water temperature
DHW tank temperature
▪ [Custom temperature]
Program when the additional leaving water temperature is turned ON and OFF.
Program when to heat up the DHW tank. The possible actions depend on an installer setting.
Possible actions 1:
▪ Storage comfort (preset value)
(a)
▪ Storage eco (preset value)
(a)
Quiet mode
▪ Storage stop
(b)
Not applicable.
(Only for field supplied domestic hot water pump for secondary return)
Program when the domestic hot water pump is turned ON and OFF.
Domestic hot water pump
(a) Start heating up until the desired setpoint (Comfort/Eco) is reached.
(b) Stop heating, even if the desired temperature is not reached yet; example: if electric tariffs are higher during the day, you can program a stop at 06:00.
To select which schedule you currently want to use
1
Go to [5]: > Select schedules.
User reference guide
16
2
Select for which control you want to use a schedule. Example:
[5.1] Room temperature.
3
Select for which operation mode you want to use a schedule.
Example: [5.1.1] Heating.
4
Select a predefined or user‑defined schedule and press .
To program a schedule
1
Go to [7.3]: > User settings > Set schedules.
2
Open an empty, predefined or user‑defined schedule.
3
Change it.
4
Save it.
Guidelines when programming
Set heating schedule
Mon 07 :00 Comfort
Select
Delete line
Clear day schedule
Copy day
Save schedule
-- : -- --
Scroll
You can:
▪ Delete lines from the schedule
▪ Clear a day schedule
▪ Copy from one day to others
Usage example: You work in a 3-shift system
If you work in a 3-shift system, you can do the following:
1
Program 3 room temperature schedules in heating mode and give them appropriate names. Example: EarlyShift, DayShift and LateShift
2
Select the schedule that you currently want to use.
4.7.3
Schedules: Example
INFORMATION
The procedures to program other schedules are similar.
In this example:
▪ Room temperature schedule in heating mode
▪ Monday = Tuesday = Wednesday = Thursday = Friday
▪ Saturday = Sunday
To program the schedule
1
Go to [7.3.1.1]: > User settings > Set schedules > Room temp. > Set heating schedule.
2
Select Empty and press .
3
Program the schedule for Monday. See below for more details.
4
Copy from Monday to Tuesday, Wednesday, Thursday and
Friday. See below for more details.
5
Program the schedule for Saturday.
6
Copy from Saturday to Sunday.
7
Save the schedule and give it a name. See below for more details.
To program the schedule for Monday
1
Use and to select Monday.
2
Press to enter the schedule for Monday.
3
Program the schedule for Monday:
▪ Use and to select an entry.
▪ Use and to change the value of an entry.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
To copy from one day to another
1
Select the day from which you want to copy and press .
Example: Monday.
2
Select Copy day and press .
3
Set the days you want to copy to Yes and press . Example:
Tuesday = Yes, Wednesday = Yes, Thursday = Yes and Friday
= Yes.
To save the schedule
1
Press , select Save schedule and press .
2
Select User defined 1, User defined 2 or User defined 3 and press .
3
Change the name and press . (Only applicable for room temperature schedules). Example: MyWeekSchedule
4.7.4
Predefined schedules: Room temperature
+ leaving water temperature (main)
: Desired temperature = Preset value (Comfort)
: Desired temperature = Preset value (Eco)
Predefined 1
Mon - Fri
07:00 09:00 17:00 23:00
Sat - Sun
08:00 23:00
Predefined 2
Mon - Fri
07:00 09:00 12:00 14:00 17:00 23:00
Sat - Sun
08:00 23:00
Predefined 3
Mon - Sun
08:00 23:00
4.7.5
Predefined schedules: Leaving water temperature (additional)
: Additional zone = On
: Additional zone = OFF
Predefined 1
Mon - Fri
07:00 09:00 17:00 23:00
Sat - Sun
08:00 23:00
Predefined 2
Mon - Fri
07:00 09:00 12:00 14:00 17:00 23:00
Sat - Sun
08:00 23:00
Predefined 3
Mon - Sun
08:00 23:00
4 Operation
4.7.6
Predefined schedules: DHW tank temperature
a
: Start production of domestic hot water. Desired DHW tank temperature = Preset value (Storage comfort)
b
: Start production of domestic hot water. Desired DHW tank temperature = Preset value (Storage eco)
Predefined 1
Mon - Sun
a b
:00
Predefined 2
Mon - Sun
a b
:00 :00
Predefined 3
Mon - Fri
a b
:00
Sat - Sun
a b
:00 :00
4.8
Weather dependent operation
In space heating control, the leaving water temperature setpoint mode can be:
▪ Fixed
▪ Weather-dependent (the leaving water temperature is determined automatically depending on the outdoor temperature)
To select the setpoint mode, see the installer reference guide.
To set the parameters for the weather-dependent curve, see below.
4.8.1
To set the weather dependent settings
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [7.7]: > User settings > Set weather dependent.
2
For main leaving water temperature zone [7.7.1], modify with
, , , , and confirm with .
3
If applicable, for additional leaving water temperature zone
[7.7.2], modify with , , , , and confirm with .
Set weather-dependent heating
Tt
c d a b
Ta
T t
Target leaving water temperature
T a
Outdoor temperature
a
Low outdoor ambient temperature
b
High outdoor ambient temperature
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
17
4 Operation
c
Desired leaving water temperature when the outdoor temperature equals or drops below the low ambient temperature. Note: in heating, this value should be higher than (d) as for low outdoor temperatures warmer water is required.
d
Desired leaving water temperature when the outdoor temperature equals or rises above the high ambient temperature. Note: in heating, this value should be lower than (c) as for high outdoor temperatures less warm water is required.
User reference guide
18
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
4 Operation
4.9
Menu structure: Overview user settings
[1] Set time/date
Date
Time
Daylight Saving Time
Clock type
[2] Holiday
Holiday
Holiday mode
From
Until
Use day schedule
Home
[5] Select schedules
Room temperature
LWT main
LWT additional
Tank temperature
[6] Information
Sensor information
Energy metering
Error handling
User permission level
Actuators
Operation modes
Running hours
Version
< >
[2] Holiday
Holiday
Holiday mode
From
Until
Operation mode
Heating
DHW
Away
[7]
User settings
Display
Temperature lock
Set schedules
Preset values
Unit of measurement
Set weather dependent
[6.2] Energy metering
Consumed elec.
Produced energy
[6.3] Error information
Error history
Contact/helpdesk number
Warning history
[6.8] Version
User interface
Indoor unit
Outdoor unit
[7.1] Display
Contrast
Backlit LCD time
User profile
Available home pages
[7.3] Set schedules
Room temp.
LWT main
LWT additional
DHW temp
DHW pump
[7.4]
Preset values
Room temperature
LWT main
Tank temperature
[7.7] Set weather dependent
Main
Additional
INFORMATION
Energy metering functionality is NOT applicable and/or
NOT valid for this unit if it is calculated by the unit. If optional external meters are used, energy metering display is valid.
[7.7.1] Main
Set weather-dependent heating
[7.7.2] Additional
Set weather-dependent heating
INFORMATION
▪ Indoor unit relates to indoor unit PCB which controls the hydraulic part of the ground source heat pump.
▪ Outdoor unit relates to outdoor unit PCB which controls the compressor module of the ground source heat pump.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
19
5 Energy saving tips
INFORMATION
Depending on the selected installer settings, settings will be visible/invisible.
4.10
Installer settings: Tables to be filled in by installer
4.10.1
Quick wizard
Setting Default
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate 0 (No)
Space heating settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
0 (LWT control)
1 (In room)
0 (1 LWT zone)
1 (Sample)
Domestic hot water settings [A.2.2]
DHW pump 0 (No)
Thermostats [A.2.2]
Contact type main 1 (Thermo ON/
OFF)
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
1 (Thermo ON/
OFF)
0 (No)
Ext. backup heat src
Alarm output
Demand PCB [A.2.2.7]
Demand PCB
0 (No)
0 (Normally open)
0 (No)
Energy metering [A.2.2]
External kWh meter 1
BUH: step 1
BUH: step 2
Auto emergency [A.5.1.2]
0 (No)
External kWh meter 2 0 (No)
Capacities (energy metering) [A.2.3]
3 kW
3 kW
Emergency Manual
Fill in…
INFORMATION
Auto emergency: By default, backup heater operation during emergency operation is NOT allowed. This means that when a heat pump failure occurs the user needs to manually confirm that backup heater may operate during emergency. If the house is unattended for longer periods, we recommend that setting [A.5.1.2] Emergency shall be set to Automatic.
4.10.2
Space heating control
Setting Default
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode 1 (Weather dep.)
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode 1 (Weather dep.)
Leaving water temperature: Delta T source [A.3.1.3]
Heating 8°C
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT 0 (No)
Fill in…
User reference guide
20
Setting Default
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type 0 (Quick)
Fill in…
4.10.3
Domestic hot water control [A.4]
Setting
Type
Maximum setpoint
Default
1 (Reheat + sched.)
60°C
Fill in…
4.10.4
Contact/helpdesk number [6.3.2]
Setting
Contact/helpdesk number —
Default Fill in…
5 Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example: under floor heating), avoid large fluctuation of the desired room temperature and do NOT let the room temperature drop too low. It will take more time and energy to heat up the room again.
▪ Use a weekly schedule for your normal space heating needs. If necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room temperature. Example: When you have a party, or when you are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode. Example:
When you stay at home during your holiday, or when you go away during your holiday.
Tips about leaving water temperature
▪ In heating mode, a lower desired leaving water temperature results in lower energy consumption and better performance.
▪ Set the desired leaving water temperature in accordance with the heat emitter type. Example: Underfloor heating is designed for lower leaving water temperature than radiators and heat pump convectors.
Tips about DHW tank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program to heat up the DHW tank to a preset value (Storage comfort = higher DHW tank temperature) during the night, because then space heating demand is lower.
▪ If heating up the DHW tank once at night is not sufficient, program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.
▪ Make sure the desired DHW tank temperature is NOT too high.
Example: After installation, lower the DHW tank temperature daily by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during periods of the day when instant hot water is necessary. Example:
In the morning and evening.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
6 Maintenance and service
6.1
Overview: Maintenance and service
The installer has to perform a yearly maintenance. You can find the contact/helpdesk number via the user interface.
As end user, you have to:
▪ Keep the area around the unit clean.
▪ Keep the user interface clean with a soft damp cloth. Do NOT use any detergents.
▪ Regularly check if the water pressure indicated on the manometer is above 1 bar.
Refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent gases into the atmosphere.
Refrigerant type: R410A
Global warming potential value: 2087.5
Periodical inspections for refrigerant leaks may be required depending on the applicable legislation. Please contact your installer for more information.
6.2
To find the contact/helpdesk number
Prerequisite: You switched the permission level to Advanced end user.
1
Go to [6.3.2]: > Information > Error handling > Contact/ helpdesk number.
7 Troubleshooting
7.1
Overview: Troubleshooting
If a malfunction occurs, is displayed on the home pages. You can press to display more information about the malfunction.
For the symptoms listed below, you can try to solve the problem yourself. For any other problem, contact your installer. You can find the contact/helpdesk number via the user interface.
7.2
To check the error history
Prerequisite: Only available if is displayed on the home pages.
1
Go to [6.3.1]: > Information > Error handling > Error history.
7.3
To check the warning history
Prerequisite: Only available if is displayed on the home pages.
1
Go to [6.3.1]: > Information > Error handling > Warning history.
6 Maintenance and service
7.4
Symptom: You are feeling too cold
(hot) in your living room
Possible cause
The desired room temperature is too low (high).
Corrective action
Increase (decrease) the desired room temperature.
The desired room temperature cannot be reached.
If the problem recurs daily, do one of the following:
▪ Increase (decrease) the room temperature preset value.
▪ Adjust the room temperature schedule.
Increase the desired leaving water temperature in accordance with the heat emitter type.
7.5
Symptom: The water at the tap is too cold
Possible cause
You ran out of domestic hot water because of unusual high consumption.
The desired DHW tank temperature is too low.
Corrective action
If you immediately need domestic hot water, activate the DHW tank booster mode. However, this consumes extra energy.
If you can wait, overrule
(increase) the active or next scheduled desired temperature so that more hot water will be produced exceptionally.
If the problems recurs daily, do one of the following:
▪ Increase the DHW tank temperature preset value.
▪ Adjust the DHW tank temperature schedule.
Example:
Program to additionally heat up the
DHW tank to a preset value
(Storage eco = lower tank temperature) during the day.
7.6
Symptom: Heat pump failure
When the heat pump fails to operate the backup heater can serve as an emergency heater and either automatically or non-automatically take over the heat load. When auto emergency is activated and a heat pump failure occurs, the backup heater will automatically take over the heat load. When a heat pump failure occurs and auto emergency is not activated, the domestic hot water and space heating operations will stop and need to be recovered manually. The user interface will then ask you to confirm whether the backup heater can take over the heat load or not. When the heat pump fails, will appear on the user interface.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
User reference guide
21
8 Relocation
Possible cause
Heat pump is damaged.
Corrective action
▪ Press to view a description of the problem.
▪ Press again.
▪ Select to allow the backup heater to take over the heat load.
▪ Call your local dealer to get the heat pump fixed.
INFORMATION
When the backup heater takes over the heat load, electricity consumption will be considerably higher.
Accessories
Labels, manuals, information sheets and equipment that are delivered with the product and that need to be installed according to the instructions in the accompanying documentation.
Optional equipment
Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
Field supply
Equipment not made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
8 Relocation
8.1
Overview: Relocation
If you want to relocate parts of your system (user interface, indoor unit, outdoor unit, DHW tank…), contact your installer. You can find the contact/helpdesk number via the user interface.
9 Disposal
9.1
Overview: Disposal
If you want to dispose parts of your system (user interface, indoor unit, outdoor unit, DHW tank…), contact your installer. You can find the contact/helpdesk number via the user interface.
10 Glossary
DHW = Domestic hot water
Hot water used, in any type of building, for domestic purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the heat pump.
Dealer
Sales distributor for the product.
Authorized installer
Technical skilled person who is qualified to install the product.
User
Person who is owner of the product and/or operates the product.
Applicable legislation
All international, European, national and local directives, laws, regulations and/or codes that are relevant and applicable for a certain product or domain.
Service company
Qualified company which can perform or coordinate the required service to the product.
Installation manual
Instruction manual specified for a certain product or application, explaining how to install, configure and maintain it.
Operation manual
Instruction manual specified for a certain product or application, explaining how to operate it.
User reference guide
22
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1C – 2015.10
4P351749-1C