Rosemount 3051 Pressure Transmitter
With the Rosemount 3051 Pressure Transmitter, you’ll gain more control over your plant. You’ll be able to
reduce product variation and complexity as well as your total cost of ownership by leveraging one device
across a number of pressure, level and flow applications. You’ll have access to information you can use to
diagnose, correct and even prevent issues. And with unparalleled reliability and experience, the Rosemount
3051 is the industry standard that will help you perform at higher levels of efficiency and safety so you can
remain globally competitive.
Rosemount 3051
February 2013
The Proven Industry Leader in Pressure Measurement

Best-in-Class performance with 0.04% reference
accuracy

Local Operator Interface (LOI) offers easy to use
configuration capabilities at the transmitter

Coplanar™ platform enables integrated pressure,
flow and level solutions


IEC 62591 (WirelessHART™) Protocol enables cost
effective installations
Selectable HART™ Revision prepares your plant for
the latest HART capabilities while ensuring
seamless integration with today's systems

Power Advisory Diagnostics provide predictive
visibility to the health of your entire electrical loop
SIL2 safety certification to IEC 61508 is available
with the full HART offering to simplify compliance

Over 20 years of backwards compatibility allows
you to invest in the latest features without adding
complexity to your plant

Setting the standard for pressure measurement
Proven best-in-class performance, reliability and safety

Over 7 million installed

Meet your application needs with extensive offering

Real world total performance of ±0.14%

Reference accuracy of ±0.04%
Flow
Pressure
Maximize Installation Flexibility with Coplanar Platform

Improve reliability and performance with integrated DP Flowmeters, DP Level and
manifolds

Easy installation with all solutions fully assembled, leak-tested and calibrated

Meet your application needs with an unsurpassed offering
Level
Table of Contents
Ordering information
Rosemount 3051C Coplanar Pressure Transmitter . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Rosemount 3051T In-Line Pressure Transmitter . . . . . . . 11
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Rosemount 3051CF Flowmeter Series . . . . . . . . . . . . . . . 17
Standard 3051 Dimensional Drawings . . . . . . . . . . . . . . 60
Rosemount 3051L Level Transmitter . . . . . . . . . . . . . . . . 36
Enhanced 3051 Dimensional Drawings . . . . . . . . . . . . . . 71
2
www.rosemount.com
February 2013
Rosemount 3051
Industry Leading Capabilities Extended to IEC 62591 (WirelessHART)

Cost effectively implement wireless on the industry's most proven platform

Optimize safety with the industry's only intrinsically safe Power Module

Eliminate wiring design and construction complexities to lower costs by 40-60%

Quickly deploy new pressure, level and flow measurements in 70% less time
Innovative, Integrated DP Flowmeters

Fully assembled, configured, and leak tested for out-of-the-box installation

Reduce straight pipe requirements, lower permanent pressure loss and achieve accurate
measurement in small line sizes

Up to 1.65% volumetric flow accuracy at 8:1 turndown
Proven, Reliable and Innovative DP Level Technologies

Connect to virtually any process with a comprehensive offering of process connections, fill
fluids, direct mount or capillary connections and materials

Quantify and optimize total system performance with QZ option

Operate at higher temperature and in vacuum applications

Optimize level measurement with cost efficient Tuned-System™ Assemblies
Instrument Manifolds – Quality, Convenient, and Easy
www.rosemount.com

Designed and engineered for optimal performance with Rosemount transmitters

Save installation time and money with factory assembly

Offers a variety of styles, materials and configurations
3
Rosemount 3051
February 2013
Rosemount 3051C Coplanar Pressure Transmitter
This ordering table contains the following Rosemount 3051C configurations:
3051C Coplanar
Pressure Transmitter
Configuration
Transmitter Output Code
4-20 mA HART
-3051
-Enhanced 3051(1)
A
FOUNDATION™ fieldbus
F
PROFIBUS® PA
W
Wireless
X
(1) The enhanced 4-20 mA HART device can be ordered with Transmitter Output option code A plus any of
the following new option codes: DA0, M4, QT, DZ, CR, CS, CT, HR5, HR7.
See Specifications and Options for more details on each configuration.
Additional Information
Specifications: page 42
Certifications: page 53
Dimensional Drawings: page 60
Table 1. 3051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
3051C
Transmitter Type
Coplanar Pressure Transmitter
Measurement Type
Standard
Standard
D
Differential
★
G
Gage
★
Expanded
A(1)
Absolute
Pressure Range
3051CD
3051CG
3051CA
1
–25 to 25 inH2O
(–62.2 to 62.2 mbar)
–25 to 25 inH2O
(–62,1 to 62.2 mbar)
0 to 30 psia
(0 to 2.1 bar)
★
2
–250 to 250 inH2O
(–623 to 623 mbar)
–250 to 250 inH2O
(–621 to 623 mbar)
0 to 150 psia
(0 to 10.3 bar)
★
3
–1000 to 1000 inH2O
(–2.5 to 2.5 bar)
–393 to 1000 inH2O
(–0.98 to 2.5 bar)
0 to 800 psia
(0 to 55.2 bar)
★
4
–300 to 300 psi
(–20.7 to 20.7 bar)
–14.2 to 300 psi
(–0.98 to 20.7 bar)
0 to 4000 psia
(0 to 275.8 bar)
★
5
–2000 to 2000 psi
(–137.9 to137.9 bar)
–14.2 to 2000 psi
(–0.98 to 137.9 bar)
Not Applicable
–3 to 3 inH2O
(–7.5 to 7.5 mbar)
Not Applicable
Not Applicable
Standard
Standard
★
Expanded
0(2)
Transmitter Output
Standard
Standard
A(3)
4–20 mA with Digital Signal Based on HART Protocol
★
F
FOUNDATION fieldbus Protocol
★
W(4)
PROFIBUS PA Protocol
★
X(5)
Wireless
★
4
www.rosemount.com
February 2013
Rosemount 3051
Table 1. 3051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Materials of Construction
Process Flange Type
Flange Material
Drain/Vent
2
Coplanar
SST
SST
★
3(6)
Coplanar
Cast C-276
Alloy C-276
★
4
Coplanar
Cast Alloy 400
Alloy 400/K-500
★
5
Coplanar
Plated CS
SST
★
7(6)
Coplanar
SST
Alloy C-276
★
8(6)
Coplanar
Plated CS
Alloy C-276
★
0
Alternate Process Connection
Standard
Standard
★
Isolating Diaphragm
Standard
Standard
2(6)
316L SST
★
3(6)
Alloy C-276
★
Expanded
4(7)
Alloy 400
5(7)
Tantalum (Available on 3051CD and CG, Ranges 2–5 only. Not available on 3051CA)
6(7)
Gold-plated Alloy 400 (Use in combination with O-ring Option Code B.)
7(7)
Gold-plated SST
O-ring
Standard
Standard
A
Glass-filled PTFE
★
B
Graphite-filled PTFE
★
Sensor Fill Fluid
Standard
Standard
1
Silicone
2(7)
Inert (Differential and Gage only)
Housing Material
★
★
Conduit Entry Size
Standard
Standard
A
Aluminum
½–14 NPT
★
B
Aluminum
M20 × 1.5
★
J
SST
½–14 NPT
★
K
SST
M20 × 1.5
★
P(8)
Engineered Polymer
No Conduit Entries
★
D
Aluminum
G½
M
SST
G½
Expanded
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
Standard
User Configurable Transmit Rate, 2.4GHz WirelessHART
★
Antenna and SmartPower
Standard
WP5
Standard
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
www.rosemount.com
★
5
Rosemount 3051
February 2013
Table 1. 3051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Options (Include with selected model number)
Plantweb Control Functionality
Standard
A01
Standard
FOUNDATION fieldbus Advanced Control Function Block Suite
★
Plantweb Diagnostic Functionality
Standard
Standard
DA0(9)(10)
Power Advisory HART Diagnostic
★
D01
FOUNDATION fieldbus Diagnostics Suite
★
Alternate Flange(11)
Standard
Standard
H2
Traditional Flange, 316 SST, SST Drain/Vent
★
H3(6)
Traditional Flange, Alloy C, Alloy C-276 Drain/Vent
★
H4
Traditional Flange, Cast Alloy 400, Alloy 400/K-500 Drain/Vent
★
H7(6)
Traditional Flange, 316 SST, Alloy C-276 Drain/Vent
★
1
HJ
DIN Compliant Traditional Flange, SST, /16 in. Adapter/Manifold Bolting
★
FA
Level Flange, SST, 2 in., ANSI Class 150, Vertical Mount
★
FB
Level Flange, SST, 2 in., ANSI Class 300, Vertical Mount
★
FC
Level Flange, SST, 3 in., ANSI Class 150, Vertical Mount
★
FD
Level Flange, SST, 3 in., ANSI Class 300, Vertical Mount
★
FP
DIN Level Flange, SST, DN 50, PN 40, Vertical Mount
★
FQ
DIN Level Flange, SST, DN 80, PN 40, Vertical Mount
★
Expanded
HK(12)
DIN Compliant Traditional Flange, SST, 10 mm Adapter/Manifold Bolting
HL
DIN Compliant Traditional Flange, SST, 12mm Adapter/Manifold Bolting (Not available on 3051CD0)
Manifold Assembly(12)(13)
Standard
Standard
S5
Assemble to Rosemount 305 Integral Manifold
★
S6
Assemble to Rosemount 304 Manifold or Connection System
★
(12)(13)
Integral Mount Primary Element
Standard
Standard
S3
Assemble to Rosemount 405 Compact Orifice Plate
★
S4(14)
Assemble to Rosemount Annubar® or Rosemount 1195 Integral Orifice
★
Seal Assemblies(13)
Standard
Standard
S1(15)
Assemble to one Rosemount 1199 seal
★
S2(16)
Assemble to two Rosemount 1199 seals
★
S7
One Seal, All-Welded System (Capillary Connection Type)
S8
Two Seals, All-Welded System (Capillary Connection Type)
S9
Two Seals, All-Welded System (One Direct Mount and One Capillary Connection Type)
S0
One Seal, All-Welded System (Direct Mount Connection Type)
6
www.rosemount.com
February 2013
Rosemount 3051
Table 1. 3051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Mounting Bracket(17)
Standard
Standard
B1
Traditional Flange Bracket for 2-in. Pipe Mounting, CS Bolts
★
B2
Traditional Flange Bracket for Panel Mounting, CS Bolts
★
B3
Traditional Flange Flat Bracket for 2-in. Pipe Mounting, CS Bolts
★
B4
Coplanar Flange Bracket for 2-in. Pipe or Panel Mounting, all SST
★
B7
B1 Bracket with Series 300 SST Bolts
★
B8
B2 Bracket with Series 300 SST Bolts
★
B9
B3 Bracket with Series 300 SST Bolts
★
BA
SST B1 Bracket with Series 300 SST Bolts
★
BC
SST B3 Bracket with Series 300 SST Bolts
★
Product Certifications
Standard
Standard
E8
ATEX Flameproof and Dust Certification
★
I1(18)
ATEX Intrinsic Safety and Dust
★
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
★
N1
ATEX Type n Certification and Dust
★
K8
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
★
E4(19)
TIIS Flame-proof
★
I4(20)
TIIS Intrinsic Safety
★
E5
FM Explosion-proof, Dust Ignition-Proof
★
I5(21)
FM Intrinsically Safe, Division 2
★
IE
FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only
★
K5
FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2
★
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
I6 (8)
CSA Intrinsic Safety
★
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n Certification
★
K7
IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
K2
INMETRO Flameproof, Instrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
N3
China Type n
★
KB
FM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
★
KD
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
★
Drinking Water Approval
Standard
DW(22)
Standard
NSF drinking water approval
★
Shipboard Approvals
Standard
SBS(7)
Standard
American Bureau of Shipping
★
Custody Transfer
Standard
C5(9)
Standard
Measurement Canada Accuracy Approval (Limited availability depending on transmitter type and range. Contact an
★
Emerson Process Management representative)
www.rosemount.com
7
Rosemount 3051
February 2013
Table 1. 3051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Bolting Material
Standard
Standard
L4
Austenitic 316 SST Bolts
★
L5
ASTM A 193, Grade B7M Bolts
★
L6
Alloy K-500 Bolts
★
Display and Interface Options
Standard
Standard
M4(23)
LCD Display with Local Operator Interface
★
M5
LCD Display
★
Calibration Certificate
Standard
Standard
Q4
Calibration Certificate
★
QG
Calibration Certificate and GOST Verification Certificate
★
QP
Calibration certification and tamper evident seal
★
Material Traceability Certification
Standard
Q8
Standard
★
Material Traceability Certification per EN 10204 3.1
Quality Certification for Safety
Standard
Standard
QS(24)
Prior-use certificate of FMEDA data
★
QT(9)(10)
Safety certified to IEC 61508 with certificate of FMEDA
★
Configuration Buttons
Standard
Standard
D4(9)
Analog Zero and Span
★
DZ(25)
Digital Zero Trim
★
Transient Protection
Standard
T1(7)(26)
Standard
★
Transient Protection Terminal Block
Software Configuration
Standard
Standard
Custom Software Configuration (Completed CDS 00806-0100-4001 for wired and 00806-0100-4100 for Wireless required
C1
★
with order)
Gage Pressure Calibration
Standard
C3
Standard
Gage Calibration (Model 3051CA4 only)
★
Alarm Levels
Standard
Standard
C4(9)(26)
Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High
★
CN(9)(26)
Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm Low
★
CR
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
CS(9)(10)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT(9)(10)
Low alarm (standard Rosemount alarm and saturation levels)
★
(9)(10)
Pressure Testing
Expanded
P1
8
Hydrostatic Testing with Certificate
www.rosemount.com
February 2013
Rosemount 3051
Table 1. 3051C Coplanar Pressure Transmitters Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Cleaning Process Area
Expanded
P2
Cleaning for Special Service
P3
Cleaning for <1 PPM Chlorine/Fluorine
Pressure Calibration
Expanded
P4
Calibrate at Line Pressure (Specify Q48 on order for corresponding certificate)
High Accuracy
Standard
P8(27)
Standard
0.04% Accuracy to 5:1 turndown (Range 2-4)
★
Flange Adapters
Standard
DF(28)
Standard
1/2 -14 NPT flange adapter(s)
★
Vent/Drain Valves
Expanded
D7
Coplanar Flange Without Drain/Vent Ports
Conduit Plug
Standard
DO(7)(29)
Standard
316 SST Conduit Plug
★
RC1/4 RC1/2 Process Connection
Expanded
D9(30)
RC ¼ Flange with RC ½ Flange Adapter - SST
Max Static Line Pressure
Standard
P9
Standard
4500 psig (310 bar) Static Pressure Limit (3051CD Ranges 2–5 only)
★
Ground Screw
Standard
V5(7)(31)
Standard
External Ground Screw Assembly
★
Surface Finish
Standard
Q16
Standard
Surface finish certification for sanitary remote seals
★
Toolkit Total System Performance Reports
Standard
QZ
Standard
Remote Seal System Performance Calculation Report
★
Conduit Electrical Connector
Standard
Standard
GE(7)
M12, 4-pin, Male Connector (eurofast®)
★
GM(7)
A size Mini, 4-pin, Male Connector (minifast®)
★
HART Revision Configuration
Standard
Standard
HR5(9)(10)(32)
Configured for HART Revision 5
★
HR7(9)(10) (33)
Configured for HART Revision 7
★
Typical Model Number: 3051CD 2 A 2 2 A 1 A B4
(1) Wireless output (Code X) available in absolute measurement type (Code A) with only range 1-4, 316L SST isolating diaphragm material (Code 2), silicone fill fluid
(Code 1), and housing code (Code P).
www.rosemount.com
9
Rosemount 3051
February 2013
(2) 3051CD0 is available only with Output Code A and X. Output Code A only available with Process Flange Code 0 (Alternate Flange H2, H7, HJ, or HK), Isolating Diaphragm
Code 2, O-ring Code A, and Bolting Option L4. Output Code X and draft range 0 only available with Silicone Fill Fluid Code 1 and Process Flange Code 0 (Alternate Flange
H2), Isolating Diaphragm Code 2, O-ring Code A, and Bolting Option L4.
(3) HART Revision 5 is the default HART output. The Enhanced 3051 can be factory or field configured to HART Revision 7. To order HART Revision 7 factory
configured, add option code HR7.
(4) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(5) Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic
Safety (option code I7).
(6) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(7) Not Available with Wireless output (output code X).
(8) Only available with Wireless output (output code X).
(9) Only available with HART 4-20 mA output (output code A).
(10) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(11) Requires 0 code in Materials of Construction for Alternate Process Connection.
(12) Not valid with optional code P9 for 4500 psi Static Pressure.
(13) “Assemble-to” items are specified separately and require a completed model number.
(14) Process Flange limited to Coplanar (codes 2, 3, 5, 7, 8) or Traditional (H2, H3, H7).
(15) Not valid with optional code D9 for RC1/2 Adaptors.
(16) Not valid for optional codes DF and D9 for Adaptors.
(17) Panel mounting bolts are not supplied.
(18) Dust approval not applicable to output code X. See “IEC 62591 (WirelessHART Protocol)” on page 59 for wireless approvals.
(19) Available only with output codes A - 4-20 mA HART and F - FOUNDATION fieldbus.
(20) Available only with 3051CD and 3051CG and output code A - 4-20 mA HART.
(21) Only Intrinsically Safe available with Wireless.
(22) Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges,
assemble-to manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish certification (Q16
code), and remote seal system report (QZ code).
(23) Not available with FOUNDATION fieldbus (output code F) or Wireless (output code X).
(24) Only Available with Standard Rosemount 3051 4-20mA HART (output code A).
(25) Only available with HART 4-20 mA output (output code A) and Wireless output (output code X)
(26) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field for the standard 3051.
(27) Only available with Standard 3051. See specification section for more information.
(28) Not valid with Alternate Process Connection options S3, S4, S5, and S6.
(29) Transmitter is shipped with a 316 SST Conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(30) Not available with Alternate Process Connection; DIN Flanges and Level Flanges.
(31) The V5 options is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(32) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(33) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
10
www.rosemount.com
February 2013
Rosemount 3051
Rosemount 3051T In-Line Pressure Transmitter
This ordering table contains the following Rosemount 3051T configurations:
Configuration
Transmitter Output Code
4-20 mA HART®
3051T In-Line
Wireless Pressure Transmitter
-3051
-Enhanced 3051(1)
A
FOUNDATION™ fieldbus
F
PROFIBUS PA
W
Wireless
X
(1) The enhanced 4-20 mA HART device can be ordered with Transmitter Output option code A plus any of
the following new option codes: DA0, M4, QT, DZ, CR, CS, CT, HR5, HR7.
See Specifications and Options for more details on each configuration.
Additional Information
Specifications: page 42
Certifications: page 53
Dimensional Drawings: page 60
Table 2. 3051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051T
In-Line Pressure Transmitter
Pressure Type
Standard
Standard
G
Gage
★
A(1)
Absolute
★
Pressure Range
3051TG(2)
3051TA
1
-14.7 to 30 psi (-1.0 to 2.1 bar)
0 to 30 psia (0 to 2.1 bar)
★
2
-14.7 to 150 psi (-1.0 to 10.3 bar)
0 to 150 psia (0 to 10.3 bar)
★
3
-14.7 to 800 psi (-1.0 to 55 bar)
0 to 800 psia (0 to 55 bar)
★
4
-14.7 to 4000 psi (-1.0 to 276 bar)
0 to 4000 psia (0 to 276 bar)
★
5
-14.7 to 10000 psi (-1.0 to 689 bar)
0 to 10000 psia (0 to 689 bar)
★
Standard
Standard
Transmitter Output
Standard
Standard
A(3)
4–20 mA with Digital Signal Based on HART Protocol
★
F
FOUNDATION fieldbus Protocol
★
W(4)
PROFIBUS PA Protocol
★
X(5)
Wireless
★
Process Connection Style
Standard
Standard
2B
1/2–14 NPT Female
★
2C(6)
G½ A DIN 16288 Male (Available in SST for Range 1–4 only)
★
Expanded
2F(7)
Coned and Threaded, Compatible with Autoclave Type F-250-C (Range 5 only)
61(7)
Non-threaded Instrument flange (Range 1-4 only)
www.rosemount.com
11
Rosemount 3051
February 2013
Table 2. 3051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Isolating Diaphragm
Process Connection Wetted Parts Material
Standard
2(8)
3
(8)
Standard
316L SST
316L SST
★
Alloy C-276
Alloy C-276
★
Sensor Fill Fluid
Standard
Standard
1
Silicone
2(7)
Inert
Housing Material
★
★
Conduit Entry Size
Standard
Standard
A
Aluminum
½–14 NPT
★
B
Aluminum
M20 × 1.5
★
J
SST
½–14 NPT
★
K
SST
M20 × 1.5
★
P(9)
Engineered polymer
No conduit entries
★
D
Aluminum
G½
M
SST
G½
Expanded
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
Standard
User Configurable Transmit Rate, 2.4GHz WirelessHART
★
Antenna and SmartPower
Standard
WP5
Standard
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
★
Options (Include with selected model number)
PlantWeb Control Functionality
Standard
A01
Standard
FOUNDATION fieldbus Advanced Control Function Block Suite
★
PlantWeb Diagnostic Functionality
Standard
Standard
DA0(10)(17)
Power Advisory HART Diagnostic
★
D01
FOUNDATION fieldbus Diagnostics Suite
★
Integral Assembly
Standard
S5(11)
Standard
Assemble to Rosemount 306 Integral Manifold
★
Diaphragm Seal Assemblies
Standard
S1(11)
Standard
Assemble to one Rosemount 1199 seal
★
Mounting Bracket(12)
Standard
B4
12
Standard
Bracket for 2-in. Pipe or Panel Mounting, All SST
★
www.rosemount.com
February 2013
Rosemount 3051
Table 2. 3051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Product Certifications
Standard
E8
(13)
Standard
ATEX Flameproof and Dust Certification
★
I1
ATEX Intrinsic Safety and Dust
★
IA
ATEX Intrinsic Safety for FISCO; for FOUNDATION fieldbus protocol only
★
N1
ATEX Type n Certification and Dust
★
K8
ATEX Flame-proof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
★
E4
TIIS Flameproof
★
I4
TIIS Intrinsic Safety
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5(14)
FM Intrinsically Safe, Division 2
★
IE
FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
I6 (9)
CSA Intrinsic Safety
★
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n Certification
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
N3
China Type n
★
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
★
KD
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
★
Drinking Water Approval
Standard
DW(15)
Standard
NSF drinking water approval
★
Shipboard Approvals
Standard
SBS(7)
Standard
American Bureau of Shipping
★
Custody Transfer
Standard
C5
Standard
Measurement Canada Accuracy Approval (Limited availability depending on transmitter type and range. Contact an
Emerson Process Management representative)
★
Calibration Certification
Standard
Standard
Q4
Calibration Certificate
★
QG
Calibration Certificate and GOST Verification Certificate
★
QP
Calibration Certification and tamper evident seal
★
Material Traceability Certification
Standard
Q8
Standard
Material Traceability Certification per EN 10204 3.1
★
Quality Certification for Safety
Standard
Standard
QS(16)
Prior-use certificate of FMEDA Data
★
QT(10)(17)
Safety certified to IEC 61508 with certificate of FMEDA
★
www.rosemount.com
13
Rosemount 3051
February 2013
Table 2. 3051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Configuration Buttons
Standard
Standard
D4(17)
Analog Zero and Span
★
DZ(18)
Digital Zero Trim
★
Display and Interface Options
Standard
Standard
M4(19)
LCD Display with Local Operator Interface
★
M5
LCD Display
★
Wireless SST Sensor Module
Standard
WSM(9)
Standard
★
Wireless SST Sensor Module
Conduit Plug
Standard
DO(7)(20)
Standard
★
316 SST Conduit Plug
Transient Terminal Block
Standard
T1(7)(21)
Standard
★
Transient Protection Terminal Block
Software Configuration
Standard
(18)
C1
Standard
Custom Software Configuration (Completed CDS 00806-0100-4001 for wired and 00806-0100-4100 for wireless required with
★
order)
Alarm Levels
Standard
Standard
C4(17)(22)
Analog Output Levels Compliant with NAMUR Recommendation NE 43, Alarm High
★
CN(17)(22)
Analog Output Levels Compliant with NAMUR Recommendation NE 43, Low Alarm
★
CR(10)(17)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
CS(10)(17)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT(10)(17)
Low alarm (standard Rosemount alarm and saturation levels)
★
Pressure Testing
Expanded
P1
Hydrostatic Testing with Certificate
Cleaning Process Area(23)
Expanded
P2
Cleaning for Special Service
P3
Cleaning for <1 PPM Chlorine/Fluorine
High Accuracy
Standard
P8(24)
Standard
0.04% Accuracy to 5:1 turndown (Range 2-4)
★
Ground Screw
Standard
V5(7)(25)
Standard
External Ground Screw Assembly
★
Surface Finish
Standard
Q16
Standard
Surface finish certification for sanitary remote seals
★
Toolkit Total System Performance Reports
Standard
QZ
14
Standard
Remote Seal System Performance Calculation Report
★
www.rosemount.com
February 2013
Rosemount 3051
Table 2. 3051T In-Line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Conduit Electrical Connector
Standard
GE(7)
GM
(7)
Standard
M12, 4-pin, Male Connector (eurofast®)
★
®
A size Mini, 4-pin, Male Connector (minifast )
★
HART Revision Configuration
Standard
HR5(10)(17)(26)
Configured for HART Revision 5
★
HR7(10)(17)(27)
Configured for HART Revision 7
★
Typical Model Number:
3051T G 5 F 2A 2 1 A B4
(1) Wireless output (code X) only available in absolute measurement type (code A) in range 1-5 with 1/2 14 NPT process connection (code 2B), and housing code
(code P).
(2) 3051TG lower range limit varies with atmospheric pressure.
(3) HART Revision 5 is the default HART output. The Enhanced 3051 can be factory or field configured to HART Revision 7. To order HART Revision 7 factory
configured, add option code HR7.
(4) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(5) Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic
Safety (option code I7).
(6) Wireless output (code X) only available in G1/2 A DIN 16288 Male process connection (code 2C) with range 1-4, 316 SST isolating diaphragm (code 2), silicone
fill fluid (code 1) and housing code (code P).
(7) Not available with Wireless output (output code X).
(8) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(9) Only available with Wireless output (output code X).
(10) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(11) “Assemble-to” items are specified separately and require a completed model number.
(12) Panel mounting bolts are not supplied.
(13) Dust approval not applicable to output code X. See “IEC 62591 (WirelessHART Protocol)” on page 59 for wireless approvals.
(14) Only Intrinsically Safe available with Wireless.
(15) Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges,
assemble-to manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish certification (Q16
code), and remote seal system report (QZ code).
(16) Only Available with Standard Rosemount 3051 4-20mA HART.
(17) Only available with HART 4-20 mA output (output code A).
(18) Only available with HART 4-20 mA output (output code A) and Wireless output (output code X).
(19) Not available with FOUNDATION Fieldbus (output code F) and Wireless output (output code X)
(20) Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
(21) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA and IE.
(22) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field for the standard 3051.
www.rosemount.com
15
Rosemount 3051
February 2013
(23) Not valid with Alternate Process Connection S5.
(24) Only available with Standard 3051. See specification section for more information.
(25) The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option.
(26) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(27) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
16
www.rosemount.com
February 2013
Rosemount 3051
Rosemount 3051CF Flowmeter Series
This ordering table contains the following Rosemount 3051CF configurations:
Configuration
Transmitter Output Code
4-20 mA HART®
-3051
-Enhanced 3051(1)
A
FOUNDATION™ fieldbus
F
PROFIBUS PA
W
Wireless
X
(1) The enhanced 4-20 mA HART device can be ordered with Transmitter Output option code A plus any of
the following new option codes: DA0, M4, QT, DZ, CR, CS, CT, HR5, HR7.
Additional Information
Specifications: page 42
Certifications: page 53
Dimensional
Rosemount
3051CFA Drawings: page 60
Annubar Flowmeter
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Product Description
3051CFA
Annubar Flowmeter
Measurement Type
Standard
D
Standard
Differential Pressure
★
Fluid Type
Standard
Standard
L
Liquid
★
G
Gas
★
S
Steam
★
Line Size
Standard
Standard
020
2-in. (50 mm)
★
025
21/2-in. (63.5 mm)
★
030
3-in. (80 mm)
★
035
31/2-in. (89 mm)
★
040
4-in. (100 mm)
★
050
5-in. (125 mm)
★
060
6-in. (150 mm)
★
070
7-in. (175 mm)
★
080
8-in. (200 mm)
★
100
10-in. (250 mm)
★
120
12-in. (300 mm)
★
www.rosemount.com
17
Rosemount 3051
February 2013
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Expanded
140
14-in. (350 mm)
160
16-in. (400 mm)
180
18-in. (450 mm)
200
20-in. (500 mm)
240
24-in. (600 mm)
300
30-in. (750 mm)
360
36-in. (900 mm)
420
42-in. (1066 mm)
480
48-in. (1210 mm)
600
60-in. (1520 mm)
720
72-in. (1820 mm)
780
78-in (1950 mm)
840
84-in. (2100 mm)
900
90-in. (2250 mm)
960
96-in (2400 mm)
Pipe I.D. Range
Standard
Standard
C
Range C from the Pipe I.D. table
★
D
Range D from the Pipe I.D. table
★
Expanded
A
Range A from the Pipe I.D. table
B
Range B from the Pipe I.D. table
E
Range E from the Pipe I.D. table
Z
Non-standard Pipe I.D. Range or Line Sizes greater than 12 inches
Pipe Material / Mounting Assembly Material
Standard
Standard
C
Carbon steel (A105)
★
S
316 Stainless Steel
★
0
No Mounting (Customer Supplied)
★
Expanded
G
Chrome-Moly Grade F-11
N
Chrome-Moly Grade F-22
J
Chrome-Moly Grade F-91
Piping Orientation
Standard
Standard
H
Horizontal Piping
★
D
Vertical Piping with Downwards Flow
★
U
Vertical Piping with Upwards Flow
★
Annubar Type
Standard
Standard
P
Pak-Lok
★
F
Flanged with opposite side support
★
Expanded
L
Flange-Lok
G
Gear-Drive Flo-Tap
M
Manual Flo-Tap
18
www.rosemount.com
February 2013
Rosemount 3051
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Sensor Material
Standard
S
Standard
★
316 Stainless Steel
Expanded
H
Alloy C-276
Sensor Size
Standard
Standard
1
Sensor size 1 — Line sizes 2-in. (50 mm) to 8-in. (200 mm)
★
2
Sensor size 2 — Line sizes 6-in. (150 mm) to 96-in. (2400 mm)
★
3
Sensor size 3 — Line sizes greater than 12-in. (300 mm)
★
Mounting Type
Standard
Standard
T1
Compression or Threaded Connection
★
A1
150# RF ANSI
★
A3
300# RF ANSI
★
A6
600# RF ANSI
★
D1
DN PN16 Flange
★
D3
DN PN40 Flange
★
D6
DN PN100 Flange
★
Expanded
A9(1)
900# RF ANSI
AF(1)
1500# RF ANSI
AT(1)
2500 # RF ANSI
R1
150# RTJ Flange
R3
300# RTJ Flange
R6
600# RTJ Flange
R9(1)
900# RTJ Flange
RF(1)
1500# RTJ Flange
RT(1)
2500# RTJ Flange
Opposite Side Support or Packing Gland
Standard
0
Standard
No opposite side support or packing gland (Required for Pak-Lok and Flange-Lok models)
★
Opposite Side Support – Required for Flanged Models
C
NPT Threaded Opposite Support Assembly – Extended Tip
★
D
Welded Opposite Support Assembly – Extended Tip
★
Expanded
Packing Gland – Required for Flo-Tap Models
Packing Gland Material
Rod Material
Packing Material
J(2)
Stainless Steel Packing Gland / Cage Nipple
Carbon Steel
PTFE
K(2)
Stainless Steel Packing Gland / Cage Nipple
Stainless Steel
PTFE
L(2)
Stainless Steel Packing Gland / Cage Nipple
Carbon Steel
Graphite
N(2)
Stainless Steel Packing Gland / Cage Nipple
Stainless Steel
Graphite
R
Alloy C-276 Packing Gland / Cage Nipple
Stainless Steel
Graphite
www.rosemount.com
19
Rosemount 3051
February 2013
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Isolation Valve for Flo-Tap Models
Standard
0
Standard
★
Not Applicable or Customer Supplied
Expanded
1
Gate Valve, Carbon Steel
2
Gate Valve, Stainless Steel
5
Ball Valve, Carbon Steel
6
Ball Valve, Stainless Steel
Temperature Measurement
Standard
Standard
T
Integral RTD – not available with Flanged model greater than class 600#
★
0
No Temperature Sensor
★
Expanded
R
Remote Thermowell and RTD
Transmitter Connection Platform
Standard
Standard
3
Direct-mount, Integral 3-valve Manifold– not available with Flanged model greater than class 600
★
5
Direct -mount, 5-valve Manifold – not available with Flanged model greater than class 600
★
7
Remote-mount NPT Connections (1/2-in. NPT)
★
Expanded
6
Direct-mount, high temperature 5-valve Manifold – not available with Flanged model greater than class 600
8
Remote-mount SW Connections (1/2-in.)
Differential Pressure Range
Standard
Standard
1
0 to 25 in H2O (0 to 62,3 mbar)
★
2
0 to 250 in H2O (0 to 623 mbar)
★
3
0 to 1000 in H2O (0 to 2,5 bar)
★
Transmitter Output
Standard
Standard
A(3)
4–20 mA with digital signal based on HART Protocol
★
F
FOUNDATION fieldbus Protocol
★
W(4)
PROFIBUS PA Protocol
★
X(5)
Wireless
★
Transmitter Housing Material
Conduit Entry Size
Standard
Standard
A
Aluminum
1/2-14 NPT
★
B
Aluminum
M20 x 1.5
★
J
SST
1
★
K
SST
M20 x 1.5
★
P(6)
Engineered polymer
No conduit entries
★
D
Aluminum
G1/2
M
SST
G1/2
/2-14 NPT
Expanded
Transmitter Performance Class
Standard
1
20
Standard
1.8% flow rate accuracy, 8:1 flow turndown, 5-yr. stability
★
www.rosemount.com
February 2013
Rosemount 3051
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
Standard
User Configurable Transmit Rate, 2.4GHz WirelessHART
★
Antenna and SmartPower
Standard
WP5
Standard
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
★
Options (Include with selected model number)
Pressure Testing
Expanded
P1(7)
Hydrostatic Testing with Certificate
PX(7)
Extended Hydrostatic Testing
Special Cleaning
Expanded
P2
Cleaning for Special Services
PA
Cleaning per ASTM G93 Level D (Section 11.4)
Material Testing
Expanded
V1
Dye Penetrant Exam
Material Examination
Expanded
V2
Radiographic Examination
Flow Calibration
Expanded
W1
Flow Calibration (Average K)
Special Inspection
Standard
Standard
QC1
Visual & Dimensional Inspection with Certificate
★
QC7
Inspection & Performance Certificate
★
Surface Finish
Standard
Standard
RL
Surface finish for Low Pipe Reynolds # in Gas & Steam
★
RH
Surface finish for High Pipe Reynolds # in Liquid
★
Material Traceability Certification
Standard
Q8(8)
Standard
Material Traceability Certification per EN 10474:2004 3.1
★
Code Conformance(9)
Expanded
J2
ANSI/ASME B31.1
J3
ANSI/ASME B31.3
Materials Conformance
Expanded
J5(10)
NACE MR-0175 / ISO 15156
Country Certification
Standard
J6
Standard
European Pressure Directive (PED)
★
Expanded
J1
Canadian Registration
www.rosemount.com
21
Rosemount 3051
February 2013
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Installed in Flanged Pipe Spool Section
Expanded
H3
150# Flanged Connection with Rosemount Standard Length and Schedule
H4
300# Flanged Connection with Rosemount Standard Length and Schedule
H5
600# Flanged Connection with Rosemount Standard Length and Schedule
Instrument Connections for Remote Mount Options
Standard
Standard
G2
Needle Valves, Stainless Steel
★
G6
OS&Y Gate Valve, Stainless Steel
★
Expanded
G1
Needle Valves, Carbon Steel
G3
Needle Valves, Alloy C-276
G5
OS&Y Gate Valve, Carbon Steel
G7
OS&Y Gate Valve, Alloy C-276
Special Shipment
Standard
Y1
Standard
Mounting Hardware Shipped Separately
★
Special Dimensions
Expanded
VM
Variable Mounting
VT
Variable Tip
VS
Variable length Spool Section
PlantWeb Control Functionality
Standard
A01(11)
Standard
FOUNDATION fieldbus Advanced Control Function Block Suite
★
PlantWeb Diagnostic Functionality
Standard
Standard
DA0(12)(13)
Power Advisory HART Diagnostic
★
D01(11)
FOUNDATION fieldbus Diagnostics Suite
★
Product Certifications
Standard
Standard
E8
ATEX Flameproof, Dust
★
I1(14)
ATEX Intrinsic Safety and Dust
★
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
★
N1
ATEX Type n and Dust
★
K8
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5(15)
FM Intrinsically Safe, Division 2
★
IE
FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5)
★
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
I6 (6)
CSA Intrinsically Safe (Wireless only)
★
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7 and E7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
22
www.rosemount.com
February 2013
Rosemount 3051
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
KD
CSA, FM, and ATEX Explosion-proof, Intrinsically Safe
★
Sensor Fill Fluid and O-ring Options
Standard
Standard
L1(16)
Inert Sensor Fill Fluid Note: Silicone fill fluid is standard.
★
L2
Graphite-Filled (PTFE) O-ring
★
LA(16)
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
★
Shipboard Approvals
Standard
SBS(16)
Standard
American Bureau of Shipping
★
Display and Interface Options
Standard
Standard
M4(17)
LCD Display with Local Operator Interface
★
M5
LCD Display
★
Transmitter Calibration Certification
Standard
Q4
Standard
Calibration Certificate for Transmitter
★
Quality Certification for Safety
Standard
Standard
QS(18)
Prior-use certificate of FMEDA data
★
QT(12)(13)
Safety certified to IEC 61508 with certificate of FMEDA
★
Transient Protection
Standard
T1(16)(19)
Standard
Transient terminal block
★
Manifold for Remote Mount Option
Standard
Standard
F2
3-Valve Manifold, Stainless Steel
★
F6
5-Valve Manifold, Stainless Steel
★
Expanded
F1
3-Valve Manifold, Carbon Steel
F3
3-Valve Manifold, Alloy C-276
F5
5-Valve Manifold, Carbon Steel
F7
5-Valve Manifold, Alloy C-276
Alarm Levels
Standard
Standard
C4(13)(20)
NAMUR Alarm and Saturation Levels, High Alarm
★
CN(13)(20)
NAMUR Alarm and Saturation Levels, Low Alarm
★
CR(12)(13)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
CS(12)(13)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT(12)(13)
Low alarm (standard Rosemount alarm and saturation levels)
★
Configuration Buttons
Standard
Standard
D4(13)
Analog Zero and Span
★
DZ(21)
Digital Zero Trim
★
Ground Screw
Standard
V5(16)(22)
Standard
External Ground Screw Assembly
www.rosemount.com
★
23
Rosemount 3051
February 2013
Table 3. Rosemount 3051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
HART Revision Configuration
Standard
Standard
HR5(12)(13)(23)
Configured for HART Revision 5
★
HR7(12)(13)(24)
Configured for HART Revision 7
★
Typical Model Number:
3051CFA D
L 060
D
C
H
P
S
2
T1
0
0
0
3
2
A
A
1
(1) Available in remote mount applications only.
(2) The cage nipple is constructed of 304 SST.
(3) HART Revision 5 is the default HART output. The Enhanced 3051 can be factory or field configured to HART Revision 7. To order HART Revision 7 factory
configured, add option code HR7.
(4) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(5) Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic
Safety (option code I7).
(6) Only available with Wireless output (output code X).
(7) Applies to assembled flowmeter only, mounting not tested.
(8) Instrument Connections for Remote Mount Options and Isolation Valves for Flo-tap Models are not included in the Material Traceability Certification.
(9) Not available with Transmitter Connection Platform 6.
(10) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(11) Only valid with FOUNDATION fieldbus output (output code F).
(12) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(13) Only available with 4-20 mA HART output (output Code A).
(14) Dust approval not applicable to output code X. See “IEC 62591 (WirelessHART Protocol)” on page 59 for wireless approvals
(15) Only Intrinsically Safe available with Wireless.
(16) Not available with Wireless output (output code X).
(17) Not available with FOUNDATION fieldbus (Output Code F) or Wireless output (Output Code X).
(18) Only Available with Standard Rosemount 3051 4-20mA HART.
(19) The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(20) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field for the standard 3051.
(21) Only available with 4-20 mA Hart output (Output Code A) and Wireless output (Output Code X).
(22) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(23) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(24) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
24
www.rosemount.com
February 2013
Rosemount 3051
Rosemount 3051CFC Compact Flowmeter
Additional Information
Specifications: page 42
Certifications: page 53
Dimensional Drawings: page 60
Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Product Description
3051CFC
Compact Flowmeter
Measurement Type
Standard
D
Standard
Differential Pressure
★
Primary Element Technology
Standard
Standard
A
Annubar Averaging Pitot Tube
★
C
Conditioning Orifice Plate
★
P
Orifice Plate
★
Material Type
Standard
S
Standard
316 SST
★
Line Size
Standard
Standard
005(1)
1/2-in. (15 mm)
★
010(1)
1-in. (25 mm)
★
015(1)
11/2-in. (40 mm)
★
020
2-in. (50 mm)
★
030
3-in. (80 mm)
★
040
4-in. (100 mm)
★
060
6-in. (150 mm)
★
080
8-in. (200 mm)
★
100(2)
10-in. (250 mm)
★
120(2)
12-in. (300 mm)
★
Primary Element Type
Standard
Standard
N000
Annubar Sensor Size 1
★
N040
0.40 Beta Ratio
★
0.65 Beta Ratio
★
(3)
N065
Temperature Measurement
Standard
0
Standard
No Temperature Sensor
★
Expanded
R
Remote Thermowell and RTD
Transmitter Connection Platform
Standard
Standard
3
Direct-mount
★
7
Remote-mount, NPT Connections
★
www.rosemount.com
25
Rosemount 3051
February 2013
Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Differential Pressure Range
Standard
Standard
1
0 to 25 in H2O (0 to 62,3 mbar)
★
2
0 to 250 in H2O (0 to 623 mbar)
★
3
0 to 1000 in H2O (0 to 2,5 bar)
★
Transmitter Output
Standard
Standard
A(4)
4–20 mA with digital signal based on HART Protocol
★
F
FOUNDATION fieldbus Protocol
★
W(5)
PROFIBUS PA Protocol
★
X(6)
Wireless
Transmitter Housing Material
★
Conduit Entry Size
Standard
Standard
A
Aluminum
1/2-14 NPT
★
B
Aluminum
M20 x 1.5
★
J
SST
1/2-14 NPT
★
K
SST
M20 x 1.5
★
P(7)
Engineered polymer
No conduit entries
★
D
Aluminum
G1/2
M
SST
G1/2
Expanded
Transmitter Performance Class
Standard
1
Standard
Up to ±1.65% flow rate accuracy, 8:1 flow turndown, 5-year stability
★
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
Standard
User Configurable Transmit Rate, 2.4GHz WirelessHART
★
Antenna and SmartPower
Standard
WP5
Standard
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
★
Options (Include with selected model number)
Installation Accessories
Standard
Standard
AB
ANSI Alignment Ring (150#) (Only required for 10-in. (250 mm) and 12-in. (300mm) line sizes)
★
AC
ANSI Alignment Ring (300#) (Only required for 10-in. (250 mm) and 12-in. (300mm) line sizes)
★
AD
ANSI Alignment Ring (600#) (Only required for 10-in. (250 mm) and 12-in. (300mm) line sizes)
★
DG
DIN Alignment Ring (PN16)
★
DH
DIN Alignment Ring (PN40)
★
DJ
DIN Alignment Ring (PN100)
★
Expanded
JB
JIS Alignment Ring (10K)
JR
JIS Alignment Ring (20K)
JS
JIS Alignment Ring (40K)
Remote Adapters
Standard
FE
26
Standard
Flange Adapters 316 SST (1/2-in NPT)
★
www.rosemount.com
February 2013
Rosemount 3051
Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
High Temperature Application
Expanded
HT
Graphite Valve Packing (Tmax = 850 °F)
Flow Calibration
Expanded
WC(8)
(8)(9)
WD
Flow Calibration, 3 pt, Conditioning Orifice Option C (all pipe schedules)
Flow Calibration, 10 pt, Conditioning Option C (All Schedules), Annubar Option A (Schedule 40)
Pressure Testing
Expanded
P1
Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2(10)
Cleaning for Special Services
PA
Cleaning per ASTM G93 Level D (Section 11.4)
Special Inspection
Standard
Standard
QC1
Visual & Dimensional Inspection with Certificate
★
QC7
Inspection and Performance Certificate
★
Transmitter Calibration Certification
Standard
Q4
Standard
Calibration Certificate for Transmitter
★
Quality Certification for Safety
Standard
Standard
QS(11)
Prior-use certificate of FMEDA data
★
QT(12) (13)
Safety certified to IEC 61508 with certificate of FMEDA
★
Material Traceability Certification
Standard
Q8
Standard
Material Traceability Certification per EN 10204:2004 3.1
★
Code Conformance
Expanded
J2
ANSI/ASME B31.1
J3
ANSI/ASME B31.3
J4
ANSI/ASME B31.8
Materials Conformance
Expanded
J5(14)
NACE MR-0175 / ISO 15156
Country Certification
Expanded
J1
Canadian Registration
Product Certifications
Standard
Standard
E8
ATEX Flameproof, Dust
★
I1(15)
ATEX Intrinsic Safety and Dust
★
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
★
N1
ATEX Type n and Dust
★
K8
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5(16)
FM Intrinsically Safe, Division 2
★
IE
FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5)
★
www.rosemount.com
27
Rosemount 3051
February 2013
Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
I6 (6)
CSA Intrinsically Safe (Wireless only)
★
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7 and E7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
KD
CSA, FM, and ATEX Explosion-proof, Intrinsically Safe
★
Sensor Fill Fluid and O-ring Options
Standard
Standard
L1(17)
Inert Sensor Fill Fluid
★
L2
Graphite-Filled (PTFE) O-ring
★
LA(17)
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
★
Shipboard Approvals
Standard
SBS(17)
Standard
American Bureau of Shipping
★
Display and Interface Options
Standard
Standard
M4(18)
LCD Display with Local Operator Interface
★
M5
LCD Display
★
Transient Protection
Standard
T1(17)(19)
Standard
Transient terminal block
★
Manifold for Remote Mount Option
Standard
Standard
F2
3-Valve Manifold, Stainless Steel
★
F6
5-Valve Manifold, Stainless Steel
★
PlantWeb Control Functionality
Standard
A01(20)
Standard
FOUNDATION fieldbus Advanced Control Function Block Suite
★
PlantWeb Diagnostic Functionality
Standard
Standard
DA0(12)(21)
Power Advisory HART Diagnostic
★
D01(13)(20)
FOUNDATION fieldbus Diagnostic Suite
★
Alarm Limit
Standard
Standard
C4(12)(13)
NAMUR Alarm and Saturation Levels, High Alarm
★
CN(12)(13)
NAMUR Alarm and Saturation Levels, Low Alarm
★
CR(21)(12)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
CS(21)(12)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT(21)(12)
Low alarm (standard Rosemount alarm and saturation levels)
★
Ground Screw
Standard
V5(17)(22)
28
Standard
External Ground Screw Assembly
★
www.rosemount.com
February 2013
Rosemount 3051
Table 4. Rosemount 3051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Configuration Buttons
Standard
Standard
D4(12)
Analog Zero and Span
★
DZ(23)
Digital Zero Trim
★
HART Revision Configuration
Standard
Standard
(12)(21)(24)
HR5
Configured for HART Revision 5
★
HR7(12)(21)(25)
Configured for HART Revision 7
★
Typical Model Number:
3051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5
(1) Available with Primary Element Technology P only.
(2) 10-in. (250 mm) and 12-in. (300 mm) line sizes not available with Primary Element Technology A.
(3) For 2-in. (50 mm) line sizes the Primary Element Type is 0.6 for Primary Element Technology Code C.
(4) HART Revision 5 is the default HART output. The Enhanced 3051 can be factory or field configured to HART Revision 7. To order HART Revision 7 factory
configured, add option code HR7.
(5) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(6) Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic
Safety (option code I7).
(7) Only available with Wireless output (output code X).
(8) Not available with Primary Element Technology P.
(9) For Annubar option A, consult factory for pipe schedules other than schedule 40.
(10) Available with Primary Element Technology C or P only.
(11) Only Available with Standard Rosemount 3051 4-20mA HART.
(12) Only available with 4-20 mA HART Output (output code A).
(13) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field for the standard 3051.
(14) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(15) Dust approval not applicable to output code X. See “IEC 62591 (WirelessHART Protocol)” on page 59 for wireless approvals
(16) Only Intrinsically Safe available with Wireless.
(17) Not available with Wireless output (output code X).
(18) Not available with output code F - FOUNDATION Fieldbus or Wireless output (output code X).
(19) The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(20) Only valid with FOUNDATION fieldbus (output code F).
(21) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(22) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(23) Only available with 4-20 mA HART Output (output code A) and Wireless output (output code X).
(24) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(25) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
www.rosemount.com
29
Rosemount 3051
February 2013
Rosemount 3051CFP Integral
Orifice Flowmeter
Additional Information
Specifications: page 42
Certifications: page 53
Dimensional Drawings: page 60
Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Product Description
3051CFP
Integral Orifice Flowmeter
Measurement Type
Standard
D
Standard
Differential Pressure
★
Body Material
Standard
S
Standard
316 SST
★
Line Size
Standard
Standard
005
1/2-in. (15 mm)
★
010
1-in. (25 mm)
★
015
11/2-in. (40 mm)
★
Process Connection
Standard
Standard
T1
NPT Female Body (Not Available with Remote Thermowell and RTD)
★
S1(1)
Socket Weld Body (Not Available with Remote Thermowell and RTD)
★
P1
Pipe Ends: NPT Threaded
★
P2
Pipe ends: Beveled
★
D1
Pipe Ends: Flanged, DIN PN16, slip-on
★
D2
Pipe Ends: Flanged, DIN PN40, slip-on
★
D3
Pipe Ends: Flanged, DIN PN100, slip-on
★
W1
Pipe Ends: Flanged, RF, ANSI Class 150, weld-neck
★
W3
Pipe Ends: Flanged, RF, ANSI Class 300, weld-neck
★
W6
Pipe Ends: Flanged, RF, ANSI Class 600, weld-neck
★
Expanded
A1
Pipe Ends: Flanged, RF, ANSI Class 150, slip-on
A3
Pipe Ends: Flanged, RF, ANSI Class 300, slip-on
A6
Pipe Ends: Flanged, RF, ANSI Class 600, slip-on
R1
Pipe Ends: Flanged, RTJ, ANSI Class 150, slip-on
R3
Pipe Ends: Flanged, RTJ, ANSI Class 300, slip-on
R6
Pipe Ends: Flanged, RTJ, ANSI Class 600, slip-on
Orifice Plate Material
Standard
S
Standard
316 SST
★
Expanded
H
Alloy C-276
M
Alloy 400
30
www.rosemount.com
February 2013
Rosemount 3051
Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Bore Size Option
Standard
Standard
0066
0.066-in. (1.68 mm) for 1/2-in. Pipe
★
0109
0.109-in. (2.77 mm) for 1/2-in. Pipe
★
0160
0.160-in. (4.06 mm) for 1/2-in. Pipe
★
0196
0.196-in. (4.98 mm) for 1/2-in. Pipe
★
0260
0.260-in. (6.60 mm) for 1/2-in. Pipe
★
0340
0.340-in. (8.64 mm) for 1/2-in. Pipe
★
0150
0.150-in. (3.81 mm) for 1-in. Pipe
★
0250
0.250-in. (6.35 mm) for 1-in. Pipe
★
0345
0.345-in. (8.76 mm) for 1-in. Pipe
★
0500
0.500-in. (12.70 mm) for 1-in. Pipe
★
0630
0.630-in. (16.00 mm) for 1-in. Pipe
★
0800
0.800-in. (20.32 mm) for 1-in. Pipe
★
0295
0.295-in. (7.49 mm) for 1 1/2-in. Pipe
★
0376
0.376-in. (9.55 mm) for 1 1/2-in. Pipe
★
0512
0.512-in. (13.00 mm) for 1 1/2-in. Pipe
★
0748
0.748-in. (19.00 mm) for 1 1/2-in. Pipe
★
1022
1.022-in. (25.96 mm) for 1 1/2-in. Pipe
★
1184
1.184-in. (30.07 mm) for 1 1/2-in. Pipe
★
Expanded
0010
0.010-in. (0.25 mm) for 1/2-in. Pipe
0014
0.014-in. (0.36 mm) for 1/2-in. Pipe
0020
0.020-in. (0.51 mm) for 1/2-in. Pipe
0034
0.034-in. (0.86 mm) for 1/2-in. Pipe
Transmitter Connection Platform
Standard
Standard
D3
Direct-mount, 3-Valve Manifold, SST
★
D5
Direct-mount, 5-Valve Manifold, SST
★
R3
Remote-mount, 3-Valve Manifold, SST
★
R5
Remote-mount, 5-Valve Manifold, SST
★
Expanded
D4
Direct-mount, 3-Valve Manifold, Alloy C-276
D6
Direct-mount, 5-Valve Manifold, Alloy C-276
D7
Direct-mount, High Temperature, 5-Valve Manifold, SST
R4
Remote-mount, 3-Valve Manifold, Alloy C-276
R6
Remote-mount, 5-Valve Manifold, Alloy C-276
Differential Pressure Ranges
Standard
Standard
1
0 to 25 in H2O (0 to 62,3 mbar)
★
2
0 to 250 in H2O (0 to 623 mbar)
★
3
0 to 1000 in H2O (0 to 2,5 bar)
★
Transmitter Output
Standard
Standard
A(2)
4–20 mA with digital signal based on HART Protocol
★
F
FOUNDATION fieldbus Protocol
★
PROFIBUS PA Protocol
★
Wireless
★
W
(3)
X(4)
www.rosemount.com
31
Rosemount 3051
February 2013
Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Transmitter Housing Material
Conduit Entry Size
Standard
Standard
A
Aluminum
1/2-14 NPT
★
B
Aluminum
M20 x 1.5
★
J
SST
1/2-14 NPT
★
K
SST
M20 x 1.5
★
Engineered polymer
No conduit entries
★
D
Aluminum
G1/2
M
SST
G1/2
P
(5)
Expanded
Transmitter Performance Class
Standard
1
Standard
up to ±1.8% flow rate accuracy, 8:1 flow turndown, 5-year stability
★
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
Standard
User Configurable Transmit Rate, 2.4GHz WirelessHART
★
Antenna and SmartPower
Standard
WP5
Standard
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
★
Options (Include with selected model number)
Transmitter Body / Bolt Material
Expanded
GT
High Temperature (850 °F / 454 °C)
Temperature Sensor
Expanded
RT(6)
Thermowell and RTD
Optional Connection
Standard
G1
Standard
DIN 19213 Transmitter Connection
★
Pressure Testing
Expanded
P1(7)
Hydrostatic Testing with Certificate
Special Cleaning
Expanded
P2
Cleaning for Special Services
PA
Cleaning per ASTM G93 Level D (Section 11.4)
Material Testing
Expanded
V1
Dye Penetrant Exam
Material Examination
Expanded
V2
Radiographic Examination
Flow Calibration
Expanded
WD(8)
32
Discharge Coefficient Verification
www.rosemount.com
February 2013
Rosemount 3051
Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Special Inspection
Standard
Standard
QC1
Visual & Dimensional Inspection with Certificate
★
QC7
Inspection and Performance Certificate
★
Material Traceability Certification
Standard
Q8
Standard
Material Traceability Certification per EN 10204:2004 3.1
★
Code Conformance
Expanded
J2(9)
ANSI/ASME B31.1
J3(9)
ANSI/ASME B31.3
J4(9)
ANSI/ASME B31.8
Materials Conformance
Expanded
J5(10)
NACE MR-0175 / ISO 15156
Country Certification
Standard
J6
Standard
European Pressure Directive (PED)
★
Expanded
J1
Canadian Registration
Transmitter Calibration Certification
Standard
Q4
Standard
Calibration Certificate for Transmitter
★
Quality Certification for Safety
Standard
Standard
QS(11)
Prior-use certificate of FMEDA data
★
QT(12)(13)
Safety certified to IEC 61508 with certificate of FMEDA
★
Product Certifications
Standard
Standard
E8
ATEX Flameproof, Dust
★
I1(14)
ATEX Intrinsic Safety and Dust
★
IA
ATEX FISCO Intrinsic Safety; for FOUNDATION fieldbus protocol only
★
N1
ATEX Type n and Dust
★
K8
ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1 and N1)
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5(15)
FM Intrinsically Safe, Division 2
★
IE
FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5)
★
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
I6 (6)
CSA Intrinsically Safe (Wireless only)
★
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7 and E7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
KB
FM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
KD
CSA, FM, and ATEX Explosion-proof, Intrinsically Safe
★
www.rosemount.com
33
Rosemount 3051
February 2013
Table 5. Rosemount 3051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Sensor Fill Fluid and O-ring Options
Standard
Standard
L1(16)
Inert Sensor Fill Fluid
★
L2
Graphite-Filled (PTFE) O-ring
★
LA(16)
Inert Sensor Fill Fluid and Graphite-Filled (PTFE) O-ring
★
Shipboard Approvals
Standard
SBS(16)
Standard
American Bureau of Shipping
★
Display and Interface Options
Standard
Standard
M4(17)
LCD Display with Local Operator Interface
★
M5
LCD Display
★
Transient Protection
Standard
T1(16)(18)
Standard
Transient terminal block
★
PlantWeb Control Functionality
Standard
A01(19)
Standard
FOUNDATION fieldbus Advanced Control Function Block Suite
★
PlantWeb Diagnostic Functionality
Standard
Standard
DA0(12)(13)
Power Advisory HART Diagnostic
★
D01(19)
FOUNDATION fieldbus Diagnostic Suite
★
Alarm Limit
Standard
Standard
C4(12)(20)
NAMUR Alarm and Saturation Levels, High Alarm
★
CN(12)(20)
NAMUR Alarm and Saturation Levels, Low Alarm
★
CR(12)(13)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
CS(12)(13)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT(12)(13)
Low alarm (standard Rosemount alarm and saturation levels)
★
Ground Screw
Standard
V5(16)(21)
Standard
External Ground Screw Assembly
★
Configuration Buttons
Standard
Standard
D4(12)
Analog Zero and Span
★
DZ(22)
Digital Zero Trim
★
HART Revision Configuration
Standard
Standard
HR5(12)(13)(23)
Configured for HART Revision 5
★
HR7(12)(13)(24)
Configured for HART Revision 7
★
Typical Model Number:
3051CFP D S 010 W1 S 0500 D3 2 A A 1 E5 M5
(1) To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.
(2) HART Revision 5 is the default HART output. The Enhanced 3051 can be factory or field configured to HART Revision 7. To order HART Revision 7 factory configured,
add option code HR7.
(3) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(4) Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic Safety
(option code I7).
34
www.rosemount.com
February 2013
Rosemount 3051
(5) Only available with Wireless output (output code X).
(6) Thermowell Material is the same as the body material.
(7) Does not apply to Process Connection codes T1 and S1.
(8) Not available for bore sizes 0010, 0014, 0020, 0034, 0066, or 0109.
(9) Not available with DIN Process Connection codes D1, D2, or D3.
(10) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply
to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(11) Only Available with Standard Rosemount 3051 4-20mA HART.
(12) Only available with 4-20 mA HART output (Option code A).
(13) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(14) Dust approval not applicable to output code X. See “IEC 62591 (WirelessHART Protocol)” on page 59 for wireless approvals
(15) Only Intrinsically Safe available with Wireless.
(16) Not available with Wireless output (output code X).
(17) Not available with FOUNDATION fieldbus (Output Code F) or Wireless output (output code X).
(18) The T1 option is not needed with FISCO Product Certifications, transient protection is included with the FISCO Product Certification code IA.
(19) Only valid with FOUNDATION fieldbus Output Code F.
(20) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field for the standard 3051.
(21) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(22) Only available with 4-20 mA output (Output Code A) and Wireless output (Output Code X).
(23) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(24) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
www.rosemount.com
35
Rosemount 3051
February 2013
Rosemount 3051L Level Transmitter
This ordering table contains the following Rosemount 3051L configurations:
Configuration
Transmitter Output Code
4-20 mA HART®
-3051
-Enhanced 3051(1)
A
FOUNDATION™ fieldbus
F
PROFIBUS PA
W
Wireless
X
(1) The enhanced 4-20 mA HART device can be ordered with Transmitter Output option code A plus any of
the following new option codes: DA0, M4, QT, DZ, CR, CS, CT, HR5, HR7.
3051L Level Transmitter
See Specifications and Options for more details on each configuration.
Additional Information
Specifications: page 42
Certifications: page 53
Dimensional Drawings: page 60
Table 6. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model
Transmitter Type
3051L
Level Transmitter
Pressure Range
Standard
Standard
2
–250 to 250 inH2O (–0,6 to 0,6 bar)
★
3
–1000 to 1000 inH2O (–2,5 to 2,5 bar)
★
4
–300 to 300 psi (–20,7 to 20,7 bar)
★
Transmitter Output
Standard
Standard
A(1)
4–20 mA with Digital Signal Based on HART Protocol
★
F
FOUNDATION fieldbus Protocol
★
W(2)
PROFIBUS PA Protocol
★
Wireless
★
X
(3)
Process Connection Size, Material, Extension length (High Side)
Standard
Code
Standard
Process Connection Size
Material
Extension Length
G0
2-in./DN 50/A
316L SST
Flush Mount Only
★
H0(4)
2-in./DN 50
Alloy C-276
Flush Mount Only
★
J0
2-in./DN 50
Tantalum
Flush Mount Only
★
A0(4)
3-in./DN 80
316L SST
Flush Mount
★
A2(4)
3-in./DN 80
316L SST
2-in./50 mm
★
A4(4)
3-in./DN 80
316L SST
4-in./100 mm
★
(4)
A6
3-in./DN 80
316L SST
6-in./150 mm
★
B0(4)
4-in./DN 100
316L SST
Flush Mount
★
B2(4)
4-in./DN 100
316L SST
2-in./50 mm
★
B4(4)
4-in./DN 100
316L SST
4-in./100 mm
★
(4)
36
www.rosemount.com
February 2013
Rosemount 3051
Table 6. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Code
Process Connection Size
Material
Extension Length
B6
4-in./DN 100
316L SST
6-in./150 mm
★
C0(4)
3-in./DN 80
Alloy C-276
Flush Mount
★
C2(4)
3-in./DN 80
Alloy C-276
2-in./50 mm
★
C4(4)
3-in./DN 80
Alloy C-276
4-in./100 mm
★
C6(4)
3-in./DN 80
Alloy C-276
6-in./150 mm
★
D0(4)
4-in./DN 100
Alloy C-276
Flush Mount
★
D2(4)
4-in./DN 100
Alloy C-276
2-in./50 mm
★
D4(4)
4-in./DN 100
Alloy C-276
4-in./100 mm
★
D6(4)
4-in./DN 100
Alloy C-276
6-in./150 mm
★
E0
3-in./DN 80
Tantalum
Flush Mount Only
★
F0
4-in./DN 100
Tantalum
Flush Mount Only
★
(4)
Mounting Flange Size, Rating, Material (High Side)
Size
Rating
Material
M
2-in.
ANSI/ASME B16.5 Class 150
CS
★
A
3-in.
ANSI/ASME B16.5 Class 150
CS
★
B
4-in.
ANSI/ASME B16.5 Class 150
CS
★
N
2-in.
ANSI/ASME B16.5 Class 300
CS
★
C
3-in.
ANSI/ASME B16.5 Class 300
CS
★
D
4-in.
ANSI/ASME B16.5 Class 300
CS
★
P
2-in.
ANSI/ASME B16.5 Class 600
CS
★
E
3-in.
ANSI/ASME B16.5 Class 600
CS
★
X(4)
2-in.
ANSI/ASME B16.5 Class 150
SST
★
F(4)
3-in.
ANSI/ASME B16.5 Class 150
SST
★
G(4)
4-in.
ANSI/ASME B16.5 Class 150
SST
★
Y(4)
2-in.
ANSI/ASME B16.5 Class 300
SST
★
H(4)
3-in.
ANSI/ASME B16.5 Class 300
SST
★
J(4)
4-in.
ANSI/ASME B16.5 Class 300
SST
★
Z(4)
2-in.
ANSI/ASME B16.5 Class 600
SST
★
L(4)
3-in.
ANSI/ASME B16.5 Class 600
SST
★
Q
DN 50
PN 10-40 per EN 1092-1
CS
★
R
DN 80
PN 40 per EN 1092-1
CS
★
S
DN 100
PN 40 per EN 1092-1
CS
★
V
DN 100
PN 10/16 per EN 1092-1
CS
★
K(4)
DN 50
PN 10-40 per EN 1092-1
SST
★
T(4)
DN 80
PN 40 per EN 1092-1
SST
★
U(4)
DN 100
PN 40 per EN 1092-1
SST
★
W(4)
DN 100
PN 10/16 per EN 1092-1
SST
★
7(4)
4 in.
ANSI/ASME B16.5 Class 600
SST
★
1
—
10K per JIS B2238
CS
2
—
20K per JIS B2238
CS
3
—
40K per JIS B2238
CS
4(4)
—
10K per JIS B2238
316 SST
5(4)
—
20K per JIS B2238
316 SST
6(4)
—
40K per JIS B2238
316 SST
Standard
Standard
Expanded
www.rosemount.com
37
Rosemount 3051
February 2013
Table 6. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Seal Fill Fluid (High Side)
Specific Gravity
Temperature Limits (Ambient Temperature of 70° F (21° C))
Standard
Standard
A
Syltherm XLT
0.85
-102 to 293 °F (-75 to 145 °C)
★
C
Silicone 704
1.07
32 to 401 °F (0 to 205 °C)
★
D
Silicone 200
0.93
-49 to 401 °F (-45 to 205 °C)
★
H
Inert (Halocarbon)
1.85
-49 to 320 °F (-45 to 160 °C)
★
G
Glycerine and Water
1.13
5 to 203 °F (-15 to 95 °C)
★
N
Neobee M-20
0.92
5 to 401 °F (-15 to 205 °C)
★
P
Propylene Glycol and
Water
1.02
5 to 203 F (-15 to 95 °C)
★
Low Pressure Side
Configuration
Flange Adapter
Diaphragm Material
Sensor Fill Fluid
11(4)
Gage
SST
316L SST
Silicone
★
21(4)
Differential
SST
316L SST
Silicone
★
22(4)
Differential
SST
Alloy C-276
Silicone
★
2A(4)(5)
Differential
SST
316L SST
Inert (Halocarbon)
★
2B(4)(5)
Differential
SST
Alloy C-276
Inert (Halocarbon)
★
31(4)
Tuned-System
Assembly with
Remote Seal
None
316L SST
Silicone
(Requires Option Code S1)
★
Standard
Standard
O-ring
Standard
A
Standard
★
Glass-filled PTFE
Housing Material
Conduit Entry Size
Standard
Standard
A
Aluminum
½–14 NPT
★
B
Aluminum
M20 × 1.5
★
J
SST
½–14 NPT
★
K
SST
M20 × 1.5
★
P(6)
Engineered polymer
No conduit entries
★
D
Aluminum
G½
M
SST
G½
Expanded
Wireless options (Requires Wireless output code X and Engineered Polymer housing code P)
Wireless Transmit Rate, Operating Frequency and Protocol
Standard
WA3
Standard
User Configurable Transmit Rate, 2.4GHz Wir
★
Antenna and SmartPower
Standard
WP5
Standard
Internal Antenna, Compatible with Green Power Module (I.S. Power Module Sold Separately)
★
Options (Include with selected model number)
PlantWeb Control Functionality
Standard
(7)
A01
38
Standard
FOUNDATION fieldbus Advanced Control Function Block Suite
★
www.rosemount.com
February 2013
Rosemount 3051
Table 6. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
PlantWeb Diagnostic Functionality
Standard
Standard
DA0(8)(13)
Power Advisory HART Diagnostic
★
D01(7)
FOUNDATION fieldbus Diagnostics Suite
★
Seal Assemblies
Standard
S1(9)
Standard
Assembled to One Rosemount 1199 Seal (Requires 1199M)
★
Product Certifications
Standard
Standard
E8
ATEX Flameproof and Dust Certification
★
I1(10)
ATEX Intrinsic Safety and Dust
★
IA
ATEX FISCO Intrinsic Safety
★
N1
ATEX Type n Certification and Dust
★
K8
ATEX Flame-proof and Intrinsic Safety Approvals (combination of I1 and E8)
★
E4
TIIS Flameproof
★
E5
FM Explosion-proof, Dust Ignition-proof
★
I5(11)
FM Intrinsically Safe, Division 2
★
IE
FM FISCO Intrinsically Safe
★
K5
FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
C6
CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
★
(6)
CSA Intrinsic Safety
★
K6
CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6 and K8)
★
E7
IECEx Flameproof, Dust Ignition-proof
★
I7
IECEx Intrinsic Safety
★
N7
IECEx Type n Certification
★
K7
IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7 and E7)
★
E2
INMETRO Flameproof
★
I2
INMETRO Intrinsic Safety
★
K2
INMETRO Flameproof, Intrinsic Safety
★
E3
China Flameproof
★
I3
China Intrinsic Safety
★
N3
China Type n
★
KB
ATEX Flame-proof and Intrinsic Safety, Type n, Dust (combination of E8, I1, and N1)
★
KD
FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
★
I6
Shipboard Approvals
Standard
SBS(5)
Standard
American Bureau of Shipping
★
Bolting Material
Standard
Standard
L4
Austenitic 316 SST Bolts
★
L5
ASTM A 193, Grade B7M bolts
★
L6
Alloy K-500 Bolts
★
L8
ASTM A 193 Class 2, Grade B8M Bolts
★
Display and Interface Options
Standard
Standard
M4(12)
LCD Display with Local Operator Interface
★
M5
LCD Display
★
www.rosemount.com
39
Rosemount 3051
February 2013
Table 6. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Calibration Certification
Standard
Standard
Q4
Calibration Certificate
★
QP
Calibration Certificate and tamper evident seal
★
QG
Calibration Certificate and GOST Verification Certificate
★
Material Traceability Certification
Standard
Standard
★
Material Traceability Certification per EN 10204 3.1
Q8
Quality Certification for Safety
Standard
Standard
QS(13)
Prior-use certificate of FMEDA data
★
QT(8)(14)
Safety certified to IEC 61508 with certificate of FMEDA
★
Toolkit Total System Performance Reports
Standard
Standard
★
Seal System Performance Calculation Report
QZ
Conduit Electrical Connector
Standard
GE
(5)
GM(5)
Standard
®
M12, 4-pin, Male Connector (eurofast )
★
A size Mini, 4-pin, Male Connector (minifast®)
★
Configuration Buttons
Standard
Standard
D4(13)
Analog Zero and Span
★
DZ(15)
Digital Zero Trim
★
Transient Protection
Standard
T1(5)(16)
Standard
★
Transient Protection
Software Configuration
Standard
C1(15)
Standard
Custom Software Configuration (Completed CDS 00806-0100-4001 for wired and 00806-0100-4100 for wireless
required with order)
★
Alarm Levels
Standard
(13)(17)
Standard
C4
NAMUR alarm and saturation levels, high alarm
★
CN(13)(17)
NAMUR alarm and saturation levels, low alarm
★
CR(8)(13)
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
CS(8)(13)
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT(8)(13)
Low alarm (standard Rosemount alarm and saturation levels)
★
Conduit Plug
Standard
DO
(5)
Standard
316 SST Conduit Plug
★
Ground Screw
Standard
V5(5)(18)
40
Standard
External Ground Screw Assembly
★
www.rosemount.com
February 2013
Rosemount 3051
Table 6. Rosemount 3051L Level Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Lower Housing Flushing Connection Options
Ring Material
Number
Size (NPT)
F1
316 SST
1
1
/4-18 NPT
★
F2
316 SST
2
1/4-18 NPT
★
F3
Alloy C-276
1
1/4-18 NPT
★
1
Standard
Standard
F4
Alloy C-276
2
316 SST
1
/4-18 NPT
1/2-14 NPT
★
F7
F8
316 SST
2
1/2-14 NPT
★
F9
Alloy C-276
1
1
/2-14 NPT
★
F0
Alloy C-276
2
1/2-14 NPT
★
★
HART Revision Configuration
Standard
Standard
HR5(8)(13)(19)
Configured for HART Revision 5
★
HR7(8)(13)(20)
Configured for HART Revision 7
★
Typical Model Number: 3051L 2 A A0 D 21 A A F1
(1) HART Revision 5 is the default HART output. The Enhanced 3051 can be factory or field configured to HART Revision 7. To order HART Revision 7 factory
configured, add option code HR7.
(2) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(3) Available approvals are FM Intrinsically Safe, (option code I5), CSA Intrinsically Safe (option code I6), ATEX Intrinsic Safety (option code I1), and IECEx Intrinsic
Safety (option code I7).
(4) Materials of Construction comply with metallurgical requirements highlighted within NACE MR0175/ISO 15156 for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining
environments.
(5) Not available with Wireless output (output code X).
(6) Only available with Wireless output (output code X).
(7) Only valid with FOUNDATION fieldbus output (output code F).
(8) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(9) “Assemble-to” items are specified separately and require a completed model number.
(10) Dust approval not applicable to output code X. See “IEC 62591 (WirelessHART Protocol)” on page 59 for wireless approvals.
(11) Only Intrinsically Safe available with Wireless.
(12) Not available with FOUNDATION fieldbus (Output Code F) or Wireless output (Output Code X).
(13) Only Available with Standard Rosemount 3051 4-20mA HART.
(14) Only available with HART 4-20 mA output (output code A).
(15) Only available with 4-20 mA HART output (Output Code A) and Wireless output (Output Code X).
(16) The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA, IE, IF, and IG.
(17) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field for the standard 3051.
(18) The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
(19) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(20) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
www.rosemount.com
41
Rosemount 3051
February 2013
Specifications
Performance Specifications
This product data sheet covers HART, Wireless, FOUNDATION fieldbus, and PROFIBUS PA protocols unless specified.
Conformance To Specification (±3 (Sigma))
Technology leadership, advanced manufacturing techniques and statistical process control ensure specification conformance to at least ±3.
Reference Accuracy
Stated reference accuracy equations include terminal based linearity, hysteresis, and repeatability.
For Wireless, FOUNDATION fieldbus and PROFIBUS PA devices, use calibrated range in place of span.
Models
Standard 3051
3051C
Ranges 2-5
±0.065% of span
For spans less than 10:1,
accuracy =
URL
 0.015 + 0.005  --------------- % of Span
 Span
Rosemount 3051 with P8(1)
Ranges 2-5
High Accuracy Option, P8
±0.04% of span
For spans less than 5:1,
accuracy =
URL
 0.015 + 0.005  --------------- % of Span
 Span
Range 1 ±0.10% of span
For spans less than 15:1,
accuracy =
NA
URL
 0.025 + 0.005  --------------- % of Span
 Span
Range 0 (CD)
3051CA
Ranges 1-4
URL
accuracy =  0.0075  --------------- % of Span
 Span
±0.065% of span
3051T
For spans less than 10:1,
Ranges 1-4
URL
accuracy =  0.0075  --------------- % of Span
 Span
± 0.04% of span
For spans less than 10:1
accuracy =
URL
 0.015 + 0.005  --------------- % of Span
 Span
± 0.10% of span
For spans less than 15:1
accuracy =
URL
 0.025 + 0.005  --------------- % of Span
 Span
±0.10% of span
For spans less than 2:1, accuracy = ±0.05% of
URL
±0.065% of span
For spans less than 10:1,
Enhanced 3051
and WirelessHART
NA
Ranges 2-4
High Accuracy Option, P8
±0.04% of span
For spans less than 5:1,
URL 
accuracy =  0.0075  -------------- % of Span
 Span
Ranges 2-4
High Accuracy Option, P8
±0.04% of span
For spans less than 5:1,
accuracy =
URL
 0.0075  --------------- % of Span
 Span
Range 5 ±0.075% of span
± 0.10% of span
For spans less than 2:1
accuracy = + 0.05% of URL
± 0.04% of span
For spans less than 10:1
accuracy =
URL
 0.0075  --------------- % of Span
 Span
± 0.04% of span
For spans less than 10:1
accuracy =
URL
 0.0075  --------------- % of Span
 Span
± 0.075% of span
NA
3051L
Ranges 2-4
±0.075% of span
For spans less than 10:1,
accuracy =
URL
 0.025 + 0.005  --------------- % of Span
 Span
NA
± 0.075% of span
For spans less than 10:1
accuracy =
URL
 0.025 + 0.005  --------------- % of Span
 Span
(1) High accuracy option P8 is not required for the Enhanced 3051.
42
www.rosemount.com
February 2013
Rosemount 3051
Flow Performance - Flow Reference Accuracy
3051CFA Annubar Flowmeter (for 3051 and enhanced 3051)
Ranges 2-3
±1.80% of Flow Rate at 8:1 flow turndown
3051CFC_A Compact Annubar Flowmeter – Annubar Option A
Uncalibrated
Calibrated
Ranges 2-3
±2.10% of Flow Rate at 8:1 flow turndown
±1.80% of Flow Rate at 8:1 flow turndown
3051CFC Compact Orifice Flowmeter – Conditioning Option C
 =0.4
 =0.65
Ranges 2-3
±1.75% of Flow Rate at 8:1 flow turndown
±1.95% of Flow Rate at 8:1 flow turndown
3051CFC Compact Orifice Flowmeter – Orifice Type Option P(1)
 =0.4
 =0.65
Ranges 2-3
±2.00% of Flow Rate at 8:1 flow turndown
±2.00% of Flow Rate at 8:1 flow turndown
3051CFP Integral Orifice Flowmeter
 <0.1
0.1<  <0.2
0.2<  <0.6
0.6<  <0.8
Ranges 2-3
±3.00% of Flow Rate at 8:1 flow turndown
±1.95% of Flow Rate at 8:1 flow turndown
±1.75% of Flow Rate at 8:1 flow turndown
±2.15% of Flow Rate at 8:1 flow turndown
(1) For smaller line sizes, see Rosemount Compact Orifice
Total Performance
Total Performance is based on combined errors of reference accuracy, ambient temperature effect, and static pressure effect at normal operating
conditions (70% of span typical reading, 740 psi (51 bar) line pressure).
For ±50 °F (28 °C) temperature changes; 0-100% relative humidity, from 1:1 to 5:1 rangedown
Models
Enhanced 3051
3051 Standard
3051C
Ranges 2-5
±0.15% of span
± 0.14% of span
Ranges 1-4
±0.15% of span
± 0.14% of span
3051T
Long Term Stability
Models
Long Term Stability (for 3051 and enhanced 3051)
3051C
Ranges 2-5
3051CD, 3051CG Low/Draft
Range
Ranges 0-1
3051CA Low Range
±0.125% of URL for 5 years
±50 °F (28 °C) temperature changes, and up to 1000 psi (6.9 MPa) line pressure.
±0.2% of URL for 1 year
Range 1
±0.125% of URL for 5 years
±50 °F (28 °C) temperature changes, and up to 1000 psi (6.9 MPa) line pressure.
Ranges 1-5
±0.125% of URL for 5 years
±50 °F (28 °C) temperature changes, and up to 1000 psi (6.9 MPa) line pressure.
3051T
www.rosemount.com
43
Rosemount 3051
February 2013
Dynamic Performance
4 - 20 mA HART(1)
Total Response Time (Td + Tc)(2):
3051C, Ranges 2-5: 100 ms
Range 1: 255 ms
Range 0: 700 ms
3051T: 100 ms
3051L: See Instrument Toolkit®
Dead Time (Td)
45 ms (nominal)
Update Rate(4)
22 times per second
FOUNDATION fieldbus
and PROFIBUS PA
protocols(3)
Typical HART Transmitter Response Time
152 ms
307 ms
N/A
152 ms
See Instrument Toolkit
97 ms
22 times per second
Transmitter Output vs. Time
Pressure Released
Td
100%
Tc
Td = Dead Time
Tc = Time Constant
Response Time = Td +Tc
63.2% of Total
Step Change
36.8%
(1) Dead time and update rate apply to all models and ranges; analog output only
(2) Nominal total response time at 75 °F (24 °C) reference conditions.
(3) Transducer block response time, Analog Input block execution time not included.
(4) Does not apply to wireless (output Code X). See “Wireless (Output Code X)” on
page 48 for wireless update rate.
0%
Time
Line Pressure Effect per 1000 psi (6,9 MPa)
For line pressures above 2000 psi (13,7 MPa) and Ranges 4-5, see user manual
(Document number 00809-0100-4007 for enhanced 3051 HART, 00809-0100-4001 for HART, 00809-0100-4100 for WirelessHART
00809-0100-4774 for FOUNDATION™ fieldbus, and 00809-0100-4797 for PROFIBUS PA).
Models
Line Pressure Effect (for 3051 and enhanced 3051)
3051CD, 3051CF
Ranges 2-3
Range 1
Range 0
Zero Error
±0.05% of URL/1000 psi (68.9 bar) for line pressures from 0 to 2000 psi (0 to 13.7 MPa)
±0.25% of URL/1000 psi (68.9 bar)
±0.125% of URL/100 psi (6.89 bar)
Span Error
±0.1% of reading/1000 psi (68.9 bar)
±0.4% of reading/1000 psi (68.9 bar)
±0.15% of reading/100 psi (6.89 bar)
Ranges 2-3
Range 1
Range 0
Ambient Temperature Effect per 50°F (28°C)
Models
Ambient Temperature Effect (for 3051 and enhanced 3051)
3051C
Ranges 2-5
Range 1
Range 0
±(0.0125% URL + 0.0625% span) from 1:1 to 5:1
±(0.025% URL + 0.125% span) from 5:1 to 150:1
±(0.1% URL + 0.25% span) from 1:1 to 30:1
±(0.25% URL + 0.05% span) from 1:1 to 30:1
3051CA
Ranges 1-4
3051T
Range 2-4
Range 1
Range 5
3051L
±(0.025% URL + 0.125% span) from 1:1 to 30:1
±(0.035% URL + 0.125% span) from 30:1 to 150:1
±(0.025% URL + 0.125% span) from 1:1 to 30:1
±(0.035% URL + 0.125% span) from 30:1 to 150:1
±(0.025% URL + 0.125% span) from 1:1 to 10:1
±(0.05% URL + 0.125% span) from 10:1 to 150:1
±(0.1% URL + 0.15% span)
See Instrument Toolkit software.
Mounting Position Effects
Models
Mounting Position Effects (for 3051 and enhanced 3051)
3051C
3051CA, 3051T
Zero shifts up to ±1.25 inH2O (3.11 mbar), which can be calibrated out. No span effect.
Zero shifts up to 2.5 inH2O (6.22 mbar), which can be calibrated out. No span effect.
With liquid level diaphragm in vertical plane, zero shift of up to 1 inH2O (2.49 mbar). With diaphragm in
horizontal plane, zero shift of up to 5 inH2O (12.43 mbar) plus extension length on extended units. All zero
shifts can be calibrated out. No span effect.
3051L
44
www.rosemount.com
February 2013
Rosemount 3051
Vibration Effect
Less than ±0.1% of URL when tested per the requirements of
IEC60770-1: 1999 field or pipeline with high vibration level (10-60 Hz
0.21 mm displacement peak amplitude / 60-2000 Hz 3g).
Power Supply Effect
Meets all relevant requirements of EN 61326 and Namur NE-21.(1)
(1) Does not apply to wireless output code X.
Electromagnetic Compatibility (EMC)
Meets all relevant requirements of EN 61326 and Namur NE-21.(1)
(1) NAMUR NE-21 does not apply to wireless output code X.
Transient Protection (Option Code T1)
Meets IEEE C62.41, Category Location B
6 kV crest (0.5 s - 100 kHz)
3 kA crest (8 × 20 microseconds)
6 kV crest (1.2 × 50 microseconds)
www.rosemount.com
45
Rosemount 3051
February 2013
Functional Specifications
Service
Liquid, gas, and vapor applications
Range and Sensor Limits
Table 7. 3051CD, 3051CG, 3051CF, and 3051L Range and Sensor Limits
Range
Minimum Span
0 (2) (3)
1(3)
2(3)
3(3)
4(3)
5(3)
Range and Sensor Limits
Lower (LRL)
3051CD, 3051CG,
3051CF, 3051L
Upper
(URL)
3051CD Differential
3051CF Flowmeters
0.10 inH2O
(0,25 mbar)
0.50 inH2O
(1,2 mbar)
1.67 inH2O
(4,14 mbar)
6.67 inH2O
(16,58 mbar)
2.00 psi
(137,90 mbar)
13.33 psi
(919,30 bar)
3.00 inH2O
(25,00 mbar)
25.00 inH2O
(62,16 mbar)
250.00 inH2O
(621,60 mbar)
1000.00 inH2O
(2,49 bar)
300.00 psi
(20,68 bar)
2000.00 psi
(137,90 bar)
-3.00 inH2O
(-7,47 mbar)
-25.00 inH2O
(-62,1 mbar)
-250.00 inH2O
(-0,62 bar)
-1000.00 inH2O
(-2,49 bar)
-300.00 psi
(-20,68 bar)
- 2000.00 psi
(-137,90 bar)
3051CG Gage(1)
3051L Differential
3051LGage(1)
NA
NA
NA
-25.00 inH2O
(-62,1 mbar)
-250.00 inH2O
(-0,62 bar)
0.50 psia
(34,47 mbar abs)
0.50 psia
(34,47 mbar abs)
0.50 psia
(34,47 mbar abs)
NA
NA
-250.00 inH2O
(-621,60 bar)
-1000.00 inH2O
(-2,49 bar)
-300.00 psi
(-20,68 bar)
NA
-250.00 inH2O
(-621,60 bar)
0.50 psia
(34,47 mbar abs)
0.50 psia
(34,47 mbar abs)
NA
(1) Assumes atmospheric pressure of -14.7 psig.
(2) Range 0 only available with 3051CD. Range 1 only available with 3051CD, 3051CG, or 3051CF. Range 5 not available with 3051L Differential and 3051 Gage.
(3) inH2O referenced at 68 degrees Fahrenheit.
Table 8. 3051CA and 3051T Range and Sensor Limits
1
2
3
4
3051T
Range and Sensor Limits
Minimum
Span
Upper
(URL)
Lower
(LRL)
0.33 psia
(20,68 mbar)
1.00 psia
(68,95 mbar)
5.33 psia
(367,27 bar)
26.6 psia
(1,84 bar)
30.00 psia
(2,07 bar)
150.00 psia
(10,34 bar)
800.00 psia
(55,16 bar)
4000.00 psia
(275,79 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
Range
Range
3051CA
1
2
3
4
5
Range and Sensor Limits
Minimum
Span
Upper
(URL)
Lower
(LRL)
Lower(1)
(LRL) (Gage)
0.33 psi
(20,68 mbar)
1.00 psi
(68,95 mbar)
5.33 psi
(367,27 mbar)
26.67 psi
(1,83 bar)
2000.00 psi
(137,90 bar)
30.00 psi
(2,07 bar)
150.00 psi
(10,34 bar)
800.00 psi
(55,16 bar)
4000.00 psi
(275,79 bar)
10000.00 psi
(689,48 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
0 psia
(0 bar)
-14.70 psig
(-1,01 bar)
-14.70 psig
(-1,01 bar)
-14.70 psig
(-1,01 bar)
-14.70 psig
(-1,01 bar)
-14.70 psig
(-1,01 bar)
(1) Assumes atmospheric pressure of 14.7 psig.
46
www.rosemount.com
February 2013
Rosemount 3051
4-20 mA HART (Output Code A)
Power Supply
External power supply required. Standard transmitter (4-20mA)
operates on 10.5-42.4 Vdc with no load
Load Limitations
Maximum loop resistance is determined by the voltage level of the
external power supply described by:
Load (s)
Max. Loop Resistance = 43.5 (Power Supply Voltage – 10.5)
The Device Dashboard presents the diagnostics in a
graphical, task-based interface that provides single-click
access to critical process/device information and descriptive
graphical troubleshooting.
Local Operator Interface
The LOI utilizes a 2 button menu with internal and external
configuration buttons. Internal buttons are always
configured for Local Operator Interface. External Buttons can
be configured for either LOI, (option code M4), Analog Zero
and Span (option code D4) or Digital Zero Trim (option code
DZ). See enhanced 3051 product manual
(00809-0100-4007) for LOI configuration menu.
1387
FOUNDATION fieldbus (Output code F)
1000
Power Supply
500
Operating
Region
External power supply required; transmitters operate on 9.0 to 32.0 V dc
transmitter terminal voltage.
Current Draw
0
10.5
20
30
42.4(1)
Voltage (Vdc)
Communication requires a minimum
loop resistance of 250 ohms.
(1) For CSA approval, power supply must not exceed 42.4 V.
17.5 mA for all configurations (including LCD display option)
Indication
Optional two line LCD display
FOUNDATION fieldbus Function Block
Execution Times
Indication
Block
Execution Time
Optional two line LCD/LOI Display
Resource
Transducer
LCD Block
Analog Input 1, 2
PID
Input Selector
Arithmetic
Signal Characterizer
Integrator
30 milliseconds
45 milliseconds
30 milliseconds
35 milliseconds
40 milliseconds
35 milliseconds
Zero and Span Adjustment Requirements
Zero and span values can be set anywhere within the range limits stated
in Table 7 and Table 8.
Span must be greater than or equal to the minimum span stated in
Table 7 and Table 8.
Output
Two-wire 4-20mA, user selectable for linear or square root output.
Digital process variable superimposed on 4-20 mA signal, available to
any host that conforms to HART protocol.
3051
Digital communications based on HART Revision 5 protocol.
Enhanced 3051
The enhanced 3051 comes with Selectable HART Revisions.
Digital communications based on HART Revision 5 (default)
or Revision 7 (option code HR7) protocol can be selected.
The HART revision can be switched in the field using any
HART based configuration tool or the optional local operator
interface (LOI).
Enhanced 3051 Features
Power Advisory Diagnostics
Power Advisory Diagnostics proactively detect and notify
you of degraded electrical loop integrity before it can affect
your process operation. Example loop problems that can be
detected include water in the terminal compartment,
corrosion of terminals, improper grounding, and unstable
power supplies.
www.rosemount.com
FOUNDATION fieldbus Parameters
Schedule Entries
Links
Virtual Communications Relationships (VCR)
7 (max.)
20 (max.)
12 (max.)
Standard Function Blocks
Resource Block
Contains hardware, electronics, and diagnostic information.
Transducer Block
Contains actual sensor measurement data including the
sensor diagnostics and the ability to trim the pressure sensor
or recall factory defaults.
LCD Block
Configures the local display.
47
Rosemount 3051
2 Analog Input Blocks
Processes the measurements for input into other function
blocks. The output value is in engineering units or custom
and contains a status indicating measurement quality.
PID Block
Contains all logic to perform PID control in the field
including cascade and feedforward.
Backup Link Active Scheduler (LAS)
The transmitter can function as a Link Active Scheduler if the current link
master device fails or is removed from the segment.
Advanced Control Function Block Suite (Option Code A01)
Input Selector Block
Selects between inputs and generates an output using
specific selection strategies such as minimum, maximum,
midpoint, average or first “good.”
Arithmetic Block
February 2013
Standard Function Blocks
Analog Input (AI Block)
The AI function block processes the measurements and
makes them available to the host device. The output value
from the AI block is in engineering units and contains a
status indicating the quality of the measurement.
Physical Block
The physical block defines the physical resources of the
device including type of memory, hardware, electronics and
diagnostic information.
Transducer Block
Contains actual sensor measurement data including the
sensor diagnostics and the ability to trim the pressure sensor
or recall factory defaults.
Indication
Optional two line LCD display
Provides pre-defined application-based equations including
flow with partial density compensation, electronic remote
seals, hydrostatic tank gauging, ratio control and others.
Local Operator Interface
The LOI utilizes a 2 button menu with external configuration
buttons.
Signal Characterizer Block
Wireless (Output Code X)
Characterizes or approximates any function that defines an
input/output relationship by configuring up to twenty X, Y
coordinates. The block interpolates an output value for a
given input value using the curve defined by the configured
coordinates.
Output
IEC 62591 (WirelessHART), 2.4 GHz DSSS
Wireless Radio (Internal Antenna, WP5 Option)
• Frequency: 2.400 - 2.485 GHz
Integrator Block
• Channels: 15
Compares the integrated or accumulated value from one or
two variables to pre-trip and trip limits and generates
discrete output signals when the limits are reached. This
block is useful for calculating total flow, total mass, or
volume over time.
• Modulation: IEEE 802.15.4 compliant DSSS
FOUNDATION fieldbus Diagnostics Suite
(Option Code D01)
• Transmission: Maximum of 10 dBm EIRP
Local Display
The optional 3-line, 7-digit LCD can display user-selectable information
such as primary variable in engineering units, scaled variable, percent of
range, sensor module temperature, and electronics temperature. The
display updates based on the wireless update rate.
The 3051C FOUNDATION fieldbus Diagnostics provide Abnormal Situation
Prevention (ASP) indication. The integral statistical process monitoring
(SPM) technology calculates the mean and standard deviation of the
process variable 22 times per second. The 3051C ASP algorithm uses
these values and highly flexible configuration options for customization
to many user-defined or application specific abnormal situations. The
detection of plugged impulse lines is the first available predefined
application.
Digital Zero Trim
PROFIBUS PA (Output Code W)
The 3051 Wireless transmitter requires the engineered polymer housing
to be selected. The standard sensor module will come with aluminum
material. If stainless steel is required, the option WSM must be selected.
Profile Version
Digital Zero trim (option DZ) is an offset adjustment to compensate for
mounting position effects, up to 5% of URL.
Update Rate
User selectable 1 sec. to 60 min.
Wireless Sensor Module for In-line Transmitters
3.02
Power Supply
External power supply required; transmitters operate on 9.0 to 32.0 V dc
transmitter terminal voltage.
Current Draw
17.5 mA for all configurations (including LCD display option)
Output Update Rate
Four times per second
48
www.rosemount.com
February 2013
Rosemount 3051
Power Module
3051T Inline
Field replaceable, keyed connection eliminates the risk of incorrect
installation, Intrinsically Safe Lithium-thionyl chloride Power Module
with PBT/PC enclosure. Ten-year life at one minute update rate.(1)
(1)
Reference conditions are 70 °F (21 °C), and routing data for three additional network devices.
NOTE: Continuous exposure to ambient temperature limits of -40 °F or
185 °F (-40 °C or 85 °C) may reduce specified life by less than 20 percent.
Overpressure Limits
Rosemount 3051CD/CG/CF
Ranges 1-4: 11000 psi (75,8 MPa)
Range 5: 26000 psig (179 MPa)
Failure Mode Alarm
HART 4-20 mA (Output option Code A)
If self-diagnostics detect a sensor or microprocessor failure, the analog
signal is driven either high or low to alert the user. High or low failure
mode is user-selectable with a jumper/switch on the transmitter. The
values to which the transmitter drives its output in failure mode depend
on whether it is configured to standard, NAMUR-compliant, or custom
levels (see Alarm Configuration below). The values for each are as
follows:
• Range 0: 750 psi (51,7 bar)
• Range 1: 2000 psig (137,9 bar)
• Ranges 2-5: 3626 psig (250 bar)
4500 psig (310,3 bar) for option code P9
Default
NAMUR compliant(1)
Custom levels(2)
High Alarm
Low Alarm
21.75 mA
22.5 mA
20.2 - 23.0 mA
3.75 mA
3.6 mA
3.4 - 3.8 mA
Rosemount 3051CA
• Range 1: 750 psia (51,7 bar)
(1) Analog output levels are compliant with NAMUR
recommendation NE 43, see option codes C4 or C5.
• Range 2: 1500 psia (103,4 bar)
• Range 3: 1600 psia (110,3 bar)
(2) Low alarm must be 0.1 mA less than low saturation and high
alarm must be 0.1 mA greater than high saturation.
• Range 4: 6000 psia (413,7 bar)
If the device is configured for HART7 Revision 7, failure information will
be passed as a status along with the Process Variable.
Rosemount 3051TG/TA
• Range 1: 750 psi (51,7 bar)
• Range 2: 1500 psi (103,4 bar)
Output Code F, W, and X
• Range 3: 1600 psi (110,3 bar)
If self-diagnostics detect a gross transmitter failure, that information
gets passed as a status along with the process variable.
• Range 4: 6000 psi (413,7 bar)
• Range 5: 15000 psi (1034,2 bar)
For 3051L or Level Flange Option Codes FA, FB, FC, FD, FP, and FQ, limit is
0 psia to the flange rating or sensor rating, whichever is lower.
Temperature Limits
Ambient
-40 to 185 °F (-40 to 85 °C)
With LCD display(1) (2): -40 to 175 °F (-40 to 80 °C)
Table 9. 3051L and Level Flange Rating Limits
Standard
Type
CS Rating
SST Rating
ANSI/ASME
ANSI/ASME
ANSI/ASME
Class 150
285 psig
275 psig
Class 300
740 psig
720 psig
Class 600
1480 psig
1440 psig
At 100 °F (38 °C), the rating decreases
with increasing temperature, per ANSI/ASME B16.5.
DIN
PN 10-40
40 bar
40 bar
DIN
PN 10/16
16 bar
16 bar
DIN
PN 25/40
40 bar
40 bar
At 248 °F (120 °C), the rating decreases
with increasing temperature, per DIN 2401.
Static Pressure Limit
Rosemount 3051CD Only
(1) For the standard 3051, LCD display may not be readable and LCD
updates will be slower at temperatures below -22 °F (-30 °C).
(2) Wireless LCD display may not be readable and LCD updates will be
slower at temperature below -4 °F (-20 °C).
Storage(1)
-50 to 230 °F (-46 to 110 °C)
With LCD display: -40 to 185 °F (-40 to 85 °C)
With Wireless Output: -40 °F to 185 °F (-40 °C to 85 °C)
(1) If storage temperature is above 85°C, perform a sensor trim prior to
installation.
Operates within specifications between static line pressures of 0.5 psia
and 3626 psig (4500 psig (310, 3 bar) for Option Code P9).
Range 0: 0.5 psia and 750 psig (3, 4 bar and 51, 7 bar)
Range 1: 0.5 psia and 2000 psig (3, 4 bar and 137, 9 bar)
Burst Pressure Limits
3051C, 3051CF Coplanar or
Traditional process flange
10000 psig (69 MPa)
www.rosemount.com
49
Rosemount 3051
February 2013
Standard 3051
Process
Analog output response to a step input change is user-selectable from
0 to 36 seconds for one time constant. This software damping is in
addition to sensor module response time.
At atmospheric pressures and above. See Table 10.
Table 10. 3051 Process Temperature Limits
3051CD, 3051CG, 3051CF, 3051CA
Silicone Fill Sensor(1)
with Coplanar Flange
–40 to 250 °F (–40 to 121 °C)(2)
with Traditional Flange
–40 to 300 °F (–40 to 149 °C)(2)(3)
with Level Flange
–40 to 300 °F (–40 to 149 °C)(2)
with 305 Integral Manifold
–40 to 300 °F (–40 to 149 °C)(2)
Inert Fill Sensor(1)
–40 to 185 °F (–18 to 85 °C)(4) (5)
3051T (Process Fill Fluid)
Silicone Fill Sensor(1)
Inert Fill Sensor(1)
–40 to 250 °F (–40 to 121 °C)(2)
–22 to 250 °F (–30 to 121 °C)(2)
3051L Low-Side
Temperature Limits
Silicone Fill Sensor(1)
–40 to 250 °F (–40 to 121 °C)(2)
Inert Fill Sensor(1)
0 to 185 °F (–18 to 85 °C) (2)
3051L High-Side Temperature Limits (Process Fill Fluid)
Syltherm® XLT
D.C. Silicone 704®
D.C. Silicone 200
Inert
Glycerin and Water
Neobee M-20
Propylene Glycol and Water
–100 to 300 °F (–73 to 149 °C)
32 to 400 °F (0 to 205 °C)
–40 to 400 °F (–40 to 205 °C)
–50 to 350 °F (–45 to 177 °C)
0 to 200 °F (–18 to 93 °C)
0 to 400 °F (–18 to 205 °C)
0 to 200 °F (–18 to 93 °C)
FOUNDATION fieldbus
Transducer block: 0.4 seconds fixed
AI Block: User configurable
PROFIBUS PA
AI Block only: User configurable
Physical Specifications
Electrical Connections
1/2–14 NPT, G1/2, and M20 × 1.5 conduit. The polymer housing (housing
code P) has no conduit entries. HART interface connections fixed to
terminal block for output code A and to 701P Power Module for Output
Code X.
Process Connections
Rosemount 3051C
1
/4–18 NPT on 21/8-in. centers
1/2–14 NPT on 2-, 21/8-, or 21/4-in. centers
Rosemount 3051L
High pressure side: 2-, 3-, or 4-in., ASME B 16.5 (ANSI) Class 150, 300 or
600 flange; 50, 80 or 100 mm, PN 40 or 10/16 flange
Low pressure side: 1/4–18 NPT on flange 1/2–14 NPT on adapter
Rosemount 3051T
(1) Process temperatures above 185 °F (85 °C) require derating the
ambient limits by a 1.5:1 ratio.
(2) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures
below 0.5 psia.
(3) 3051CD0 process temperature limits are –40 to 212 °F
(–45 to 100 °C)
(4) 160 °F (71 °C) limit in vacuum service.
(5) Not available for 3051CA.
1
/2–14 NPT female.
A DIN 16288 Male (available in SST for Range 1–4 transmitters only)
Autoclave type F-250-C (Pressure relieved 9/16–18 gland thread; 1/4 OD
high pressure tube 60° cone; available in SST for Range 5 transmitters
only).
Rosemount 3051CF
For 3051CFA, see 00813-0100-4485 Rosemount 485 Annubar
For 3051CFC, see 00813-0100-4485 Rosemount 405 Compact Orifice
Plate
For 3051CFP, see 00813-0100-4485 Rosemount 1195 Integral Orifice
Humidity Limits
Process-Wetted Parts
0–100% relative humidity
Drain/Vent Valves
Turn-On Time
316 SST, Alloy C-276, or Alloy 400 material (Alloy 400 not available with
3051L)
Performance within specifications less than 2.0 seconds (10.0 s for
PROFIBUS PA protocol) after power is applied to the transmitter.(1)
(1) Does not apply to wireless option code X.
Volumetric Displacement
Less than 0.005 in3 (0,08 cm3)
Process Flanges and Adapters
Plated carbon steel, SST cast CF-8M (cast version of 316 SST, material per
ASTM-A743), C-Type cast alloy CW12MW, or cast alloy M30C
Wetted O-rings
Glass-filled PTFE or Graphite-filled PTFE
Damping
4-20 mA HART
Enhanced 3051
Analog output response to a step input change is user-enterable from
0.0 to 60 seconds for one time constant. This software damping is in
addition to sensor module response time.
50
www.rosemount.com
February 2013
Rosemount 3051
316L SST
Alloy C-276
Alloy 400
Tantalum
Gold-plated Alloy 400
Gold-plated SST
•
•
•
•
•
•
3051CA
3051T
Isolating Diaphragm Material
Cover O-rings
3051CD
3051CG
Process Isolating Diaphragms
•
•
•
•
•
Buna-N
Silicone (for wireless option code X)
Power Module
Field replaceable, keyed connection eliminates the risk of incorrect
installation, Intrinsically Safe Lithium-thionyl chloride Power Module
with PBT enclosure.
•
•
Rosemount 3051L Process Wetted Parts
Flanged Process Connection (Transmitter High Side)
Process Diaphragms, Including Process Gasket
Surface
316L SST, Alloy C-276, or Tantalum
Extension
CF-3M (Cast version of 316L SST, material per ASTM-A743),
or Alloy C-276. Fits schedule 40 and 80 pipe.
Mounting Flange
Zinc-cobalt plated CS or SST
Reference Process Connection (Transmitter Low Side)
Isolating Diaphragms
316L SST or Alloy C-276
Reference Flange and Adapter
CF-8M (Cast version of 316 SST, material per ASTM-A743)
Non-Wetted Parts
Electronics Housing
Low-copper aluminum or CF-8M (Cast version of 316 SST). Enclosure
Type 4X, IP 65, IP 66, IP 68
Housing Material Code P: PBT/PC with NEMA 4X and IP66/67/68
Coplanar Sensor Module Housing
CF-3M (Cast version of 316L SST, material per ASTM-A743)
Bolts
ASTM A449, Type 1 (zinc-cobalt plated carbon steel)
ASTM F593G, Condition CW1 (Austenitic 316 SST)
ASTM A193, Grade B7M (zinc plated alloy steel)
Alloy K-500
Sensor Module Fill Fluid
Coplanar uses Silicone or inert Halocarbon
In-line series uses silicone Fluorinert® FC-43
Process Fill Fluid (3051L only)
Syltherm XLT, D.C. Silicone 704,
D.C. Silicone 200, inert, glycerin and water, Neobee M-20 or propylene
glycol and water
Paint
Polyurethane
www.rosemount.com
51
Rosemount 3051
February 2013
Shipping Weights
Table 11. Transmitter Weights without Options(1)
Transmitter
Standard 3051 In lb. (kg)
Wireless In lb. (kg)
3051C
3051T
3051L
6.0 (2,7)
3.0 (1,4)
3.9 (1,8)
1.9 (0,86)
Table 12 on page 52
Table 12 on page 52
(1) Transmitter weights include the sensor module and housing only
(aluminum for standard 3051 and polymer for wireless).
Table 12. 3051L Weights without Options
Flange
2-in., 150
3-in., 150
4-in., 150
2-in., 300
3-in., 300
4-in., 300
2-in., 600
3-in., 600
DN 50/PN 40
DN 80/PN 40
DN 100/
PN 10/16
DN 100/
PN 40
Flush
lb. (kg)
2-in. Ext.
lb. (kg)
4-in. Ext.
lb. (kg)
6-in. Ext.
lb. (kg)
12.5 (5,7)
17.5 (7,9)
23.5 (10,7)
17.5 (7,9)
22.5 (10,2)
32.5 (14,7)
15.3 (6,9)
25.2 (11,4)
13.8 (6,2)
19.5 (8,8)
17.8 (8,1)
—
19.5 (8,8)
26.5 (12,0)
—
24.5 (11,1)
35.5 (16,1)
—
27.2 (12,3)
—
21.5 (9,7)
19.8 (9,0)
—
20.5 (9,3)
28.5 (12,9)
—
25.5 (11,6)
37.5 (17,0)
—
28.2 (12,8)
—
22.5 (10,2)
20.8 (9,5)
—
21.5 (9,7)
30.5 (13,8)
—
26.5 (12,0)
39.5 (17,9)
—
29.2 (13,2)
—
23.5 (10,6)
21.8 (9,9)
23.2 (10,5)
25.2 (11,5)
26.2 (11,9)
27.2 (12,3)
Table 13. Transmitter Option Weights
Code
J, K, L, M
J, K, L, M
M4/M5
M5
B4
B1, B2, B3
B7, B8, B9
BA, BC
H2
H3
H4
H7
FC
FD
FA
FB
FP
FQ
WSM
52
Option
Stainless Steel Housing (T)
Stainless Steel Housing (C, L, H, P)
LCD display for wired transmitter
LCD Display for Wireless Output
SST Mounting Bracket for Coplanar Flange
Mounting Bracket for Traditional Flange
Mounting Bracket for Traditional Flange
SST Bracket for Traditional Flange
Traditional Flange
Traditional Flange
Traditional Flange
Traditional Flange
Level Flange—3 in., 150
Level Flange—3 in., 300
Level Flange—2 in., 150
Level Flange—2 in., 300
DIN Level Flange, SST, DN 50, PN 40
DIN Level Flange, SST, DN 80, PN 40
SST Sensor Module
Power Module (701PGNKF)
Add
lb. (kg)
3.9 (1,8)
3.1 (1,4)
0.5 (0,2)
0.1 (0,04)
1.0 (0,5)
2.3 (1,0)
2.3 (1,0)
2.3 (1,0)
2.4 (1,1)
2.7 (1,2)
2.6 (1,2)
2.5 (1,1)
10.8 (4,9)
14.3 (6,5)
10.7 (4,8)
14.0 (6,3)
8.3 (3,8)
13.7 (6,2)
1.0 (0,45)
0.4 (0,18)
www.rosemount.com
February 2013
Rosemount 3051
Product Certifications
Approved Manufacturing Locations
C6
Rosemount Inc. — Chanhassen, Minnesota USA
Emerson Process Management GmbH & Co. — Wessling, Germany
Emerson Process Management Asia Pacific
Private Limited — Singapore
Beijing Rosemount Far East Instrument Co., LTD — Beijing, China
Emerson Process Management LTDA — Sorocaba, Brazil
Emerson Process Management (India) Pvt. Ltd. — Daman, India
European Directive Information
The EC declaration of conformity for all applicable European directives
for this product can be found on the Rosemount website at
www.rosemount.com. A hard copy may be obtained by contacting an
Emerson Process Management representative.
Ordinary Location Certification for Factory Mutual
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and fire
protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational Safety
and Health Administration (OSHA).
European certifications
E8
HART Protocol
E5
Explosion-Proof and Dust Ignition Proof
Certificate No: 0T2H0.AE
Applicable Standards: FM Class 3600 – 1998, FM Class 3615 –
2006, FM Class 3810 – 2005, ANSI/NEMA 250 - 2003
Markings: Explosion-Proof for Class I, Division 1, Groups B, C, and
D.
Dust-Ignition-Proof for Class II, Division 1, Groups E, F, G; and Class
III, Division 1.
T5 (Ta = -50 °C to +85 °C), Factory Sealed, Enclosure Type 4x
I5
1.) The Model 3051 transmitter housing contains aluminum and is
considered a potential risk of ignition by impact or friction. Care
must be taken into account during installation and use to prevent
impact and friction.
2.) The Model 3051 transmitter with the transient terminal block
(Option code T1) will not pass the 500Vrms dielectric strength
test and this must be taken into account during installation.
CSA international
All CSA hazardous location approved transmitters are certified to
ANSI/ISA 12.27.01-2003.
www.rosemount.com
ATEX Flame-Proof and Dust
Certification No.: KEMA00ATEX2013X, Baseefa11ATEX0275
Applicable Standards: EN60079-0: 2012, EN60079-1: 2007,
EN60079-26: 2007, IEC 60079-0:2011, EN60079-31:2009
Markings:
II 1/2 G, Ex d IIC T6 (–50  Ta  65 °C) Ga/Gb,
Ex d IIC T5 (–50  Ta  80 °C) Ga/Gb,
II D Ex ta IIIC T50°C T500 60°C Da
1180
Process Temp
Ambient Temp
Temp Class
-50 to 65
-50 to 65
T6
-50 to 80
-50 to 80
T5
Special Conditions for Safe Use (X):
1.) In case of repair, contact the manufacturer for information on
the dimensions of the flameproof joints.
Intrinsically Safe and Non-Incendive
Certificate No: 1Q4A4.AX
Applicable Standards: FM Class 3600 – 1998, FM Class 3610 –
2010, FM Class 3611 – 2004, FM Class 3810 – 2005
Markings: Intrinsically Safe for use in Class I, Division 1, Groups A,
B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division
1 when connected per Rosemount drawing 03031-1019 and
00375-1130 (When used with a Field Communicator);
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Temperature Code: T4 (Ta = -50 °C to +70 °C), T5 (Ta = -50 °C to
+40 °C), Enclosure Type 4x.
Special Conditions for Safe Use:
Explosionproof, Dust-Ignitionproof, Intrinsically Safe
and Division 2
Certificate No.: 1053834
Applicable Standards: ANSI/ISA 12.27.01-2003, CSA Std. C22.2
No. 30 -M1986, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2.
No.157-92, CSA Std. C22.2 No. 213 - M1987
Markings: Explosionproof for Class I, Division 1, Groups B, C and D.
Dust-Ignitionproof for Class II and Class III, Division 1, Groups E, F
and G.
Intrinsically safe for Class I, Division 1, Groups A, B, C and D when
connected in accordance with Rosemount drawing 03031-1024.
Temperature Code T3C.
Suitable for Class I, Division 2 Groups A, B, C, and D.
Enclosure type 4X, factory sealed. Single Seal (See Drawing
03031-1053).
2.) This device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the environmental
conditions to which the diaphragm will be subjected. The
manufacturer's instructions for installation and maintenance shall
be followed in detail to assure safety during its expected lifetime.
3.) The capacitance of the wrap around label to the enclosure,
1.6E-9 F, exceeds the limit in Table 9 of IEC 60079-0. The user shall
determine suitability for the specific application.
4.) Wait at least 2 minutes after powering down device before
opening covers, when a hazardous atmosphere is present.
I1
ATEX Intrinsic Safety and Dust
Certificate No.: BAS 97ATEX1089X
Applicable Standards: IEC60079-0:2011, EN60079-11: 2012,
EN60079-31: 2009,
Markings:
II 1 GD, Ex ia IIC T4 Ga (–60  Ta  +70 °C),
Ex ia IIC T5 Ga (–60  Ta  +40 °C)
Ex ta IIIC T50 °C T500 60°C Da
IP66,
1180
Table 14. Input Parameters
Ui = 30V
Ii = 200 mA
Pi = 0.9 W
Ci = 0.012 μF
53
Rosemount 3051
February 2013
Special Conditions for Safe Use (X):
Conditions of Certification (X):
1.) The apparatus is not capable of withstanding the 500 V
insulation test required by EN60079-11. This must be taken into
account when installing the apparatus.
1.) This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the environmental
conditions to which the diaphragm will be subjected. The
manufacturer's instructions for installation and maintenance shall
be followed in detail to assure safety during its expected lifetime.
2.) The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however care should be
taken to protect it from impact or abrasion if located in Zone 0.
N1
2.) For information on the dimensions of the flameproof joints the
manufacturer shall be contacted.
ATEX Non-incendive/Type n and Dust
Certification No.: BAS 00ATEX3105X
Applicable Standards: IEC60079-0:2011, EN60079-15:2010,
EN60079-31:2009
Markings:
II 3 GD, Ex nA IIC Gc T5 (–40  Ta  70 °C),
Ex ta IIIC T50 °C T500 60°C Da, IP66
1180
3.) The capacitance of the wrap around label to the enclosure,
1.6E-9 F, exceeds the limit in Table 9 of IEC 60079-0. The user shall
determine suitability for the specific application.
4.) Wait at least 2 minutes after powering down device before
opening covers, when a hazardous atmosphere is present.
I7
Specific Conditions for Safe Use (X):
1.) The apparatus is not capable of withstanding the 500 V
insulation test required by EN60079-15. This must be taken into
account when installing the apparatus.
Table 15. Input Parameters
2.) This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the environmental
conditions to which the diaphragm will be subjected. The
manufacturer’s instructions for installation and maintenance shall
be followed in detail to assure safety during its expected lifetime.
In case of repair, contact the manufacturer for more information
on the dimensions of the flameproof joints.
Ui = 30 V
Ii = 200 mA
Pi = 0.9 W
Ci = 0.012 μF
Li = 0
Conditions of Certification (X):
Japanese certifications
E4
1.) If the apparatus is fitted with an optional 90V transient
suppressor, it is not capable of withstanding the 500V insulation
test required by IEC 60079-11. This must be taken into account
when installing the apparatus.
TIIS Flame-Proof
Markings: Ex d IIC T6
I4
Certificate
Description
TC15850
3051C/D/1 4–20 mA HART — no meter
TC15851
3051C/D/1 4–20 mA HART — with meter
TC15854
3051T/G/1 4–20 mA HART, SST, Silicon — no
meter
TC15855
3051T/G/1 4–20 mA HART, Alloy C-276, Silicon —
no meter
TC15856
3051T/G/1 4–20 mA HART, SST, Silicon — with
meter
TC15857
3051T/G/1 4–20 mA HART, Alloy C-276, Silicon —
with meter
54
2.) The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should be
taken to protect it from impact or abrasion if located in Zone 0.
N7
IECEx Flame-proof and Dust
Certification No.: IECEx KEM 09.0034X, IECEx BAS 10.0034
Applicable Standards: IEC60079-0:2011, IEC60079-1:2007,
IEC60079-26:2006, IEC60079-31:2008
Markings: Ex d IIC T5...T6 Ga/Gb, T5 (-50 °C  Ta  80 °C)/T6 (-50 °C
 Ta  65 °C), Ex ta IIIC T50°C T50060°C Da
Process
Temp
Ambient Temp
Temp Class
-50 to 65
-50 to 65
T6
-50 to 80
-50 to 80
T5
IECEx Type ‘n’
Certification No.: IECEx BAS 09.0077X
Applicable Standards: IEC60079-0:2011, IEC60079-15:2010
Markings: Ex nA IIC T5 Gc (-40  Ta  70 °C)
Conditions of Certification (X):
The apparatus is not capable of withstanding the 500V insulation
test required by IEC 60079-15. This must be taken into account
when installing the apparatus.
Inmetro certifications
E2
TIIS Intrinsic Safety
Certification No.: TC16406
Markings: Ex ia IIC T4
IECEx certifications
E7
IECEx Intrinsic Safety
Certification No.: IECEx BAS 09.0076X
Applicable Standards: IEC60079-0:2011, IEC 60079-11: 2011
Markings: Ex ia IIC T5 Ga (-60°C  Ta  40°C), Ex ia IIC T4 Ga (-60°C
 Ta  70°C)
Flameproof
Certificate No: CEPEL 97.0073X (Mfg USA and Singapore)
Certificate No: CEPEL 07.1383X (Mfg Brazil)
Applicable Standards: IEC60079-0:2008, IEC60079-1:2009,
IEC60079-26:2008, IEC60529:2009
Markings: Ex d IIC T6 Ga/Gb (-50°C  Ta  +65°C)
Ex d IIC T5 Ga/Gb (-50°C  Ta  +80°C)
IP66W
www.rosemount.com
February 2013
I2
Intrinsic Safety
Certificate No.: CEPEL 97.0072X (Mfg USA and Singapore)
Certificate No.: CEPEL 07.1412X (Mfg Brazil)
Applicable Standards: IEC60079-0:2008, IEC60079-11:2009,
IEC60079-26:2008, IEC60529:2009
Markings: Ex ia IIC Ga T5 (-20°C  Ta  +40°C)
Ex ia IIC Ga T4 (-20°C  Ta  +70°C)
IP66W
Table 16. Input Parameters
Ui = 30 V
Ii = 200 mA
Pi = 0.9 W
Ci = 0.012 μF
Li = Desprezivel
Specific Conditions for Safe Use (X):
Rosemount 3051
Combinations of certifications
Stainless steel certification tag is provided when optional approval
is specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval
types. Permanently mark the approval label to distinguish it from
unused approval types.
K5 – E5, I5
K6 – C6, E8, I1
K7 – E7, I7, N7
K8 – E8, I1, N1
KB – E5, I5, E6, C6
KD – E5, I5, E6, C6, E8, I1
See Certificate.
China certifications
E3
Flameproof and Dust
NEPSI Certificate No.: GYJ091065X
Applicable Standards: GB3836.1-2000,
GB3836.4-2000,GB4208-1993, GB12476-2000
Markings: Ex d II C T5/T6, -50°~+80°C (T5), -50°~+65°C (T6), DIP
A21 TA T90°C, IP66
Specific Conditions for Safe Use (X):
Refer to Appendix B of the Rosemount 3051 reference manual
(00809-0100-4001).
I3
Intrinsic Safety and Dust
NEPSI Certificate No: GYJ091066X
Applicable Standards: GB3836.1-2000,
GB3836.2-2000,GB4208-1993, GB12476-2000
Markings: Ex ia II C T4/T5, -60°~+40°C (T5), -60°~+70°C (T4), DIP
A21 TA T80°C
Specific Conditions for Safe Use (X):
Refer to Appendix B of the Rosemount 3051 reference manual
(00809-0100-4001).
N3
China Type n - Non-Sparking
NEPSI Certificate No.: GYJ101111X
Applicable Standards: GB3836.1-2000, GB3836.8-2003
Markings: Ex nA nL IIC T5 (-40 °C < TA < 70 °C)
Specific Conditions for Safe Use (X):
Refer to Appendix B of the Rosemount 3051 reference manual
(00809-0100-4001).
www.rosemount.com
55
Rosemount 3051
February 2013
Foundation™ Fieldbus and Profibus PA Protocols
Hazardous Locations Certifications
North American Certifications
European Certifications
FM Approvals
I1
E5
I5
Explosion-Proof and Dust Ignition Proof
Certificate No: 0T2H0.AE
Applicable Standards: FM Class 3600 – 1998, FM Class 3615 –
2006, FM Class 3810 – 2005, ANSI/NEMA 250 2003
Markings: Explosion-Proof for Class I, Division 1, Groups B,
C, and D.
Dust-Ignition-Proof for Class II, Division 1, Groups E, F, G, and Class
III, Division 1.
T5 (Ta = -50 °C to +85 °C), Factory Sealed, Enclosure Type 4x.
Table 17. Input Parameters
Ui = 30V
Ii = 300 mA
Pi = 1.3 W
Ci = 0 μF
Intrinsically Safe and Non-Incendive
Certificate No: 1Q4A4.AX
Applicable Standards: FM Class 3600 – 1998, FM Class 3610 –
2010, FM Class 3611 – 2004, FM Class 3810 – 2005
Markings: Intrinsically Safe for use in Class I, Division 1, Groups A,
B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division
1 when connected per Rosemount drawing 03031-1019 and
00375-1130 (When used with a Field Communicator);
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Temperature Code: T4 (Ta = -50 °C to +60 °C), Enclosure Type 4x.
Special Conditions for Safe Use (X):
Special Conditions for Safe Use (X):
1.) The apparatus is not capable of withstanding the 500 V
insulation test required by EN60079-11. This must be taken into
account when installing the apparatus.
2.) The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however care should be
taken to protect it from impact or abrasion if located in Zone 0.
IA
1.) The Model 3051 transmitter housing contains aluminum and is
considered a potential risk of ignition by impact or friction. Care
must be taken into account during installation and use to prevent
impact and friction.
2.) The Model 3051 transmitter with the transient terminal block
(Option code T1) will not pass the 500Vrms dielectric strength
test and this must be taken into account during installation.
Ui = 17.5 V
Ii = 380 mA
Pi = 5.32 W
Ci =  5 μF
Li = 10 μH
All CSA hazardous approved transmitters are certified per ANSI/ISA
12.27.01-2003.
Explosionproof, Dust-Ignitionproof, Intrinsically Safe
and Division 2
Certificate No.: 1053834
Applicable Standards: ANSI/ISA 12.27.01-2003, CSA Std. C22.2
No. 30 -M1986, CSA Std. C22.2 No.142-M1987, CSA Std. C22.2.
No.157-92, CSA Std. C22.2 No. 213 - M1987
Markings: Explosionproof for Class I, Division 1, Groups B, C and D.
Dust-Ignitionproof for Class II and Class III, Division 1, Groups E, F
and G.
Intrinsically safe for Class I, Division 1, Groups A, B, C and D when
connected in accordance with Rosemount drawing 03031-1024.
Temperature Code T3C.
Suitable for Class I, Division 2 Groups A, B, C, and D.
Enclosure type 4X, factory sealed. Single Seal (See Drawing
03031-1053).
ATEX FISCO Intrinsic Safety
Certificate No.: BAS 97ATEX1089X
Applicable Standards: IEC60079-0:2011, EN60079-11: 2012,
EN60079-31: 2009,
Markings:
II 1 GD, Ex ia IIC T4 Ga (–60  Ta  +60 °C),
Ex ta IIIC T50 °C T500 60°C Da, Ui = 30 V Ii = 200 mA Pi = 0.9 W Ci =
0.012 μF, IP66,
1180
Table 18. Input Parameters
Canadian Standards Association (CSA)
C6
ATEX Intrinsic Safety and Dust
Certificate No.: BAS 97ATEX1089X
Applicable Standards: IEC60079-0:2011, EN60079-11: 2012,
EN60079-31: 2009,
Markings:
II 1 GD, Ex ia IIC T4 Ga (–60  Ta  +60 °C),
Ex ta IIIC T50 °C T500 60°C Da,
1180
Special Conditions for Safe Use (X):
1.) The apparatus is not capable of withstanding the 500 V
insulation test required by EN60079-11. This must be taken into
account when installing the apparatus.
2.) The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however care should be
taken to protect it from impact or abrasion if located in Zone 0.
N1
ATEX Non-incendive/Type n and Dust
Certification No.: BAS 00ATEX3105X
Applicable Standards: IEC60079-0:2011, EN60079-15:2010,
EN60079-31:2009
Markings:
II 3 GD, Ex nA IIC Gc T5 (–40  Ta  70 °C),
Ex ta IIIC T50 °C T500 60°C Da, IP66
Special Conditions for Safe Use (X):
1.) The apparatus is not capable of withstanding the 500 V
insulation test required by EN60079-15. This must be taken into
account when installing the apparatus.
56
www.rosemount.com
February 2013
Rosemount 3051
2.) This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the environmental
conditions to which the diaphragm will be subjected. The
manufacturer’s instructions for installation and maintenance shall
be followed in detail to assure safety during its expected lifetime.
In case of repair, contact the manufacturer for more information
on the dimensions of the flameproof joints.
E8
E7
ATEX Flameproof and Dust
Certification No.: KEMA00ATEX2013X, Baseefa11ATEX0275
Applicable Standards: EN60079-0: 2012, IEC60079-0:2011,
EN60079-1:2007, EN60079-26:2007, EN60079-31:2009
Markings:
II 1/2 G, Ex d IIC T6 (–50  Ta  65 °C) Ga/Gb,
Ex d IIC T5 (–50  Ta  80 °C) Ga/Gb,
II 1 D, Ex ta IIIC T50°C
T50060°C Da
1180
Process
Temp
Ambient
Temp
Temp Class
-50 to 65
-50 to 65
T6
-50 to 80
-50 to 80
T5
4.) Wait at least 5 minutes after powering down device before
opening covers, when a hazardous atmosphere is present.
Ambient
Temp
Temp Class
-50 to 65
-50 to 65
T6
-50 to 80
-50 to 80
T5
1.) This device contains a thin wall diaphragm. Installation,
maintenance, and use shall take into account the environmental
conditions to which the diaphragm will be subjected. The
manufacturer's instructions for installation and maintenance shall
be followed in detail to assure safety during its expected lifetime.
2.) For information on the dimensions of the flameproof joints the
manufacturer shall be contacted.
3.) The capacitance of the wrap around label to the enclosure,
1.6E-9 F, exceeds the limit in Table 9 of IEC 60079-0. The user shall
determine suitability for the specific application.
1.) In case of repair, contact the manufacturer for information on
the dimensions of the flameproof joints.
3.) The capacitance of the wrap around label to the enclosure,
1.6E-9 F, exceeds the limit in Table 9 of IEC 60079-0. The user shall
determine suitability for the specific application.
Process
Temp
Special Conditions for Safe Use (X):
Special Conditions for Safe Use (X):
2.) This device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the environmental
conditions to which the diaphragm will be subjected. The
manufacturer's instructions for installation and maintenance shall
be followed in detail to assure safety during its expected lifetime.
IECEx Flame-proof
Certification No.: IECEx KEM 09.0034X
Applicable Standards: IEC60079-0:2011, IEC60079-1:2007-04,
IEC60079-26:2006,
Markings: Ex d IIC T5...T6 Ga/Gb, T5 (-50 °C  Ta  80 °C)/T6 (-50 °C
 Ta  65 °C)
4.) Wait at least 5 minutes after powering down device before
opening covers, when a hazardous atmosphere is present.
N7
IECEx Type ‘n’
Certification No.: IECEx BAS 09.0077X
Applicable Standards: IEC60079-0:2011, IEC60079-15:2010
Markings: Ex nA IIC T5 Gc (-40  Ta  70 °C)
Special Conditions for Safe Use (X):
The apparatus is not capable of withstanding the 500V insulation
test required by IEC 60079-15. This must be taken into account
when installing the apparatus.
IECEx Certifications
I7
IECEx Intrinsic Safety
Certification No.: IECEx BAS 09.0076X
Applicable Standards: IEC60079-0:2011, IEC 60079-11:2011
Markings: Ex ia IIC T4 Ga (-60°C  Ta  60°C)
Table 19. Input Parameters
Ui = 30 V
Ii = 300 mA
Pi = 1.3 W
Ci = 0 μF
Li = 0 μH
Special Conditions for Safe Use (X):
1.) If the apparatus is fitted with an optional 90V transient
suppressor, it is not capable of withstanding the 500V insulation
test required by IEC 60079-11. This must be taken into account
when installing the apparatus.
2.) The enclosure may be made of aluminum alloy and given a
protective polyurethane paint finish; however, care should be
taken to protect it from impact or abrasion if located in Zone 0.
www.rosemount.com
57
Rosemount 3051
February 2013
TIIS Certifications
Special Conditions for Safe Use (X):
E4
Refer to Appendix B of Rosemount 3051 reference manual
(00809-0100-4001).
TIIS Flame-Proof
Ex d IIC T6
Certificate
TC15852
TC15853
TC15858
TC15859
TC15860
TC15861
Description
3051C/D/1 FOUNDATION Fieldbus
— no display
3051C/D/1 FOUNDATION Fieldbus
— with display
3051T/G/1 FOUNDATION Fieldbus, SST, Silicon
— no display
3051T/G/1 FOUNDATION Fieldbus, Alloy C-276,
Silicon — no display
3051T/G/1 FOUNDATION Fieldbus, SST, Silicon
— with display
3051T/G/1 FOUNDATION Fieldbus, Alloy C-276,
Silicon — with display
Inmetro certifications
E2
I2
Flameproof
Certificate No: CEPEL 97.0073X (Mfg USA and Singapore)
Certificate No: CEPEL 07.1383X (Mfg Brazil)
Applicable Standards: IEC60079-0:2008, IEC60079-1:2009,
IEC60079-26:2008, IEC60529:2009
Markings: Ex d IIC T6 Ga/Gb (-50°C  Ta  +65°C)
Ex d IIC T5 Ga/Gb (-50°C  Ta  +80°C)
IP66W
N3
China Type n - Non-Sparking
NEPSI Certificate No.: GYJ101111X
Applicable Standards: GB3836.1-2000, GB3836.8-2003
Markings: Ex nA nL IIC T5 (-40 °C  TA  70 °C)
Special Conditions for Safe Use (X):
Refer to Appendix B of Rosemount 3051 reference manual
(00809-0100-4001).
Combinations of Certifications
Stainless steel certification tag is provided when optional approval is
specified. Once a device labeled with multiple approval types is
installed, it should not be reinstalled using any other approval types.
Permanently mark the approval label to distinguish it from unused
approval types.
K5 – E5, I5
K6 – E5, I5, C6, E1, I1
K7 – E7, I7, N7
K8 – E8, I1, N1
KB – E5, I5, E1, I1
KD – E5, I5, E6, C6, I1
Intrinsic Safety
Certificate No.: CEPEL 97.0072X (Mfg USA and Singapore)
Certificate No.: CEPEL 07.1412X (Mfg Brazil)
Applicable Standards: IEC60079-0:2008, IEC60079-11:2009,
IEC60079-26:2008, IEC60529:2009
Markings: Ex ia IIC Ga T4 (-20°C  Ta  +60°C)
IP66W
Table 20. Input Parameters
Ui = 30 V
Ii = 300 mA
Pi = 1.3 W
Ci = 0.012 μF
Li = desprezivel
Special Conditions for Safe Use (X):
See Certificate.
China Certifications
E3
Flameproof
NEPSI Certificate No.: GYJ091065X
Applicable Standards: GB3836.1-2000,
GB3836.4-2000,GB4208-1993, GB12476-2000
Markings: Ex d II C T5/T6, -50°~+80°C (T5), -50°~+65°C (T6), DIP
A21 TA T90°C, IP66
Special Conditions for Safe Use (X):
Refer to Appendix B of Rosemount 3051 reference manual
(00809-0100-4001).
I3
58
Intrinsic Safety
NEPSI Certificate No: GYJ091067X
Applicable Standards: GB3836.1-2000,
GB3836.2-2000,GB4208-1993, GB12476-2000
Markings: Ex ia IIC T4 (-60°C ~+60°C), DIP A20 TA T70°C
www.rosemount.com
February 2013
Rosemount 3051
IEC 62591 (WirelessHART Protocol)
Approved manufacturing locations
Rosemount Inc. — Chanhassen, Minnesota USA
Fisher-Rosemount GmbH & Co. — Wessling, Germany
Emerson Process Management Asia Pacific Private Limited —
Singapore
Beijing Rosemount Far East Instrument Co., LTD — Beijing,
China
European directive information
The surface resistivity of the transmitter is greater than one
gigaohm. To avoid electrostatic charge build-up, it must not be
rubbed or cleaned with solvents or a dry cloth.
The Model 3051 Wireless pressure Transmitter shall only be used
with the 701PGNKF Rosemount Smartpower Battery Pack.
CSA - Canadian Standards Association
I6
The most recent revision of the EC declaration of conformity
can be found at www.rosemount.com.
Telecommunication compliance
All wireless devices require certification to ensure that they
adhere to regulations regarding the use of the RF spectrum.
Nearly every country requires this type of product
certification. Emerson is working with governmental
agencies around the world to supply fully compliant
products and remove the risk of violating country directives
or laws governing wireless device usage.
European certifications
I1
FCC and IC
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions: This device
may not cause harmful interference. This device must accept
any interference received, including interference that may
cause undesired operation. This device must be installed to
ensure a minimum antenna separation distance of 20 cm
from all persons.
Ordinary location certification for FM
As standard, the transmitter has been examined and tested
to determine that the design meets basic electrical,
mechanical, and fire protection requirements by FM, a
nationally recognized testing laboratory (NRTL) as
accredited by the Federal Occupational Safety and Health
Administration (OSHA).
North American certifications
Factory Mutual (FM) approvals
I5
CSA Intrinsically Safe
Certificate No: 2526009
Applicable Standards: CSA C22.2 No. 0-M91, CSA C22.2 No.
159-92
Markings: Intrinsically Safe For Class I, Division I, Groups A, B, C, D
T4 (-40 °C to 70 °C)
Intrinsically safe when installed according to Rosemount drawing
03031-1063
Enclosure Type 4X/IP66/IP68
ATEX Intrinsic Safety
Certificate No: Baseefa12ATEX0228X
Applicable Standards: EN60079-11:2012, EN60079-0:2012
Markings: Ex ia IIC T4 Ga (-40 °C Ta 70 °C)
II 1G
IP66/68
1180
Specific Conditions for Safe Use (X):
The plastic enclosure may constitute a potential electrostatic
ignition risk and must not be rubbed or cleaned with a dry cloth.
For use with Rosemount 701PGNKF only
I7
IECEx Intrinsic Safety
Certificate No: IECEx BAS 12.0124X
Applicable Standards: IEC60079-11:2011, IEC60079-0:2011
Markings: Ex ia IIC T4 Ga (-40 °C Ta 70 °C)
IP66/68
Specific Conditions for Safe Use:
The plastic enclosure may constitute a potential electrostatic
ignition risk and must not be rubbed or cleaned with a dry cloth.
For Use with Rosemount 701PGNKF only
FM Intrinsically Safe
Certificate No: 3045342
Applicable Standards: Class 3600:2011, Class 3610:2010, Class
3810: 2005
Markings: Intrinsically Safe for Class I, Division I, Groups A, B, C, D
Zone Marking: Class I Zone 0, AEx ia IIC
T4 (-40 °C to 70 °C)
Intrinsically Safe when installed according to Rosemount Drawing
03031-1062
Enclosure Type 4X/IP66/IP68
Specific Conditions for Safe Use:
The inline pressure sensor may contain more than 10% aluminum
and is considered a potential risk of ignition by impact or friction.
Care must be taken into account during installation and use to
prevent impact and friction.
www.rosemount.com
59
Rosemount 3051
February 2013
Standard 3051 Dimensional Drawings
Standard 3051C Exploded View
A.
B.
C.
D.
E.
(1)
F.
G.
J.
K.
H.
I.
N.
O.
P.
L.
M.
Q.
1) Span and Zero Adjustment Buttons are standard with 4-20 mA. Local Operator Interface buttons are optional for PROFIBUS PA protocol. Local Configuration
Buttons are not available with FOUNDATION fieldbus.
Standard 3051C Exploded View Labels
A. Cover
B. Cover O-ring
C. Terminal Block
D. Electronics Housing
E. Local Configuration Buttons
F. Certification Label
60
G. Electronics Board
H. Name Plate
I.Sensor Module
J. Housing Rotation Set Screw (180 degree
maximum rotation without further
disassembly)
K. Coplanar Flange
L. Drain/Vent Valve
M. Flange Adapters
N. Process O-Ring
O. Flange Adapter O-Ring
P. Flange Alignment Screw (not pressure
retaining)
Q. Flange Bolts
www.rosemount.com
February 2013
Rosemount 3051
Standard 3051C Coplanar Flange(1)
5.32 (135)
4.1
(105)
4.45 (113)
8.2 (209)
6.54 (166)
(1) For FOUNDATION fieldbus and PROFIBUS PA transmitters with LCD Display, housing length is 5.78 in. (147 mm).
3051 Wireless Housing with Coplanar Flange
www.rosemount.com
61
Rosemount 3051
February 2013
Standard 3051C Coplanar Flange with Rosemount 305 3-Valve Coplanar Integral Manifold
7.54 (192)
5.5 (140)
Max Open
10.60 (270) Max
Open
Dimensions are in inches (millimeters)
Coplanar Flange Mounting Configurations with
Optional Bracket (B4) for 2-in. Pipe or Panel Mounting
2.8
(72)
4.29
(109)
5
PANEL MOUNTING
2.8 (71)
/16 ⫻ 11/2 Bolts
for Panel Mounting
(Not Supplied)
7.1
(181)
3
/8–16 × 11/4 Bolts
for Mounting
to Transmitter
6.2
(156)
2.8
(71)
1.1 (28)
3.4 (85)
4.8
(120)
PIPE MOUNTING
2-inch U-Bolt
for Pipe Mounting
6.0 (152)
3.3
(83)
Dimensions are in inches (millimeters)
62
www.rosemount.com
February 2013
Rosemount 3051
Standard 3051C Coplanar with Traditional Flange
7.9
(201)
Drain/
Vent
Valve
1
/2–14 NPT
Flange
Adapter
(Optional)
1.1
(28
3.5
(87)
1.63 (41)
1.1
(28)
2.13
(54)
Standard 3051C Coplanar with Rosemount 305 3-Valve Traditional Integral Manifold
6.25
(159)
1/2–14 NPT
Flange
Adapter
(Optional)
Drain/
Vent
Valve
3.63
(92)
1.1
(28
3.5
(87)
1.1
(28)
6.2 (158)
Max Open
2.13
(54)
8.9
(266)
2.7 (69)
Max Open
Dimensions are in inches (millimeters)
www.rosemount.com
63
Rosemount 3051
February 2013
Traditional Flange Mounting Configurations with
Optional Brackets for 2-in. Pipe or Panel Mounting
Panel Mounting Bracket (option B2/B8)
2-in. Pipe Mounting Bracket (option B1/B7/BA)
9.2 (235)
4.2 (106)
Impulse Piping
2.7
(67)
1.1 (28)
3.8 (95)
5
/16 x 7/8 Bolts for Panel
Mounting (Not Supplied)
9.6
(243)
2.7 (67)
6.2 (158)
2.81(71)
1.4 (33)
PANEL MOUNTING
BRACKET
PIPE MOUNTING
BRACKET
4.6 (116)
2-in. Pipe Mounting Bracket (option B3/B9/BC)
4.85
(123)
11.52
(293)
1.94 (49)
5.32
(135)
6.2
(158)
Dimensions are in inches (millimeters)
64
www.rosemount.com
February 2013
Rosemount 3051
Standard 3051T Dimensional Drawings(1)
5.32 (135)
4.1 (105)
4.45 (113)
7.2
(183)
(1) For FOUNDATION fieldbus and PROFIBUS PA transmitters with LCD Display, housing length is 5.78 in. (146 mm).
3051T Wireless Housing Dimensional Drawings
www.rosemount.com
65
Rosemount 3051
February 2013
Standard 3051T with Rosemount 306 2-Valve I Integral Manifold
4.85
(123)
4.1
(105)
6.25
(159)
Dimensions are in inches (millimeters)
Standard 3051T Typical Mounting Configurations with Optional Mounting Bracket
Pipe Mounting
Panel Mounting
2.9
(72)
5.1
(130)
2
(50)
6.2
(156)
2.8 (71)
3.5
(90)
6.3
(160)
4.8 (120)
6.9 (175)
Dimensions are in inches (millimeters)
66
www.rosemount.com
February 2013
Rosemount 3051
Rosemount Standard 3051CFA Pak-Lok Annubar Flowmeter(1)
Front View
Side View
Top View
D
C
B
A
(1) The Pak-Lok Annubar model is available up to 600# ANSI (1440 psig at 100 °F (99 bar at 38 °C)).
Table 21. Standard 3051CFA Pak-Lok Annubar Flowmeter Dimensional Data
Sensor Size
A (Max)
B (Max)
C (Max)
D (Max)
1
2
3
8.50 (215.9)
11.0 (279.4)
12.00 (304.8)
14.60 (370.8)
16.35 (415.3)
19.10 (485.1)
9.00 (228.6)
9.00 (228.6)
9.00 (228.6)
6.00 (152.4)
6.00 (152.4)
6.00 (152.4)
Dimensions are in inches (millimeters)
www.rosemount.com
67
Rosemount 3051
February 2013
Rosemount Standard 3051CFC Compact Orifice Flowmeter
Compact Orifice Plate
Orifice Plate Front View
Orifice Plate Top View
(Primary Element Type code P)
Orifice Plate Side View
Conditioning Orifice Plate
(Primary Element Type code C)
1.13-in. (28.7 mm)
wafer thickness
Table 22. Dimensional Drawings
Primary
Element Type
A
B
Transmitter Height
C
D
Type P and C
5.62 (143)
Transmitter Height + A
6.27 (159)
7.75 (197) - closed
8.25 (210) - open
6.00 (152) - closed
6.25 (159) - open
Dimensions are in inches (millimeters)
68
www.rosemount.com
February 2013
Rosemount 3051
Rosemount Standard 3051CFP Integral Orifice Flowmeter
Side View
Bottom View
Front View
10.3
(261.81)
8.8 (223.46)
6.3
(160.55)
5.3
(134.51)
Dimensions are in inches (millimeters).
Line Size
Dimension
J (Beveled/Threaded pipe ends)
J (RF slip-on, RTJ slip-on, RF-DIN slip on)
J (RF 150#, weld neck)
J (RF 300#, weld neck)
J (RF 600#, weld neck)
K (Beveled/Threaded pipe ends)
K (RF slip-on, RTJ slip-on, RF-DIN slip on)(1)
K (RF 150#, weld neck)
K (RF 300#, weld neck)
K (RF 600#, weld neck)
B.D. (Bore Diameter)
1/2-in. (15 mm)
1-in. (25 mm)
12.54 (318.4)
20.24 (514.0)
12.62 (320.4)
20.32 (516.0)
14.37 (364.9)
22.37 (568.1)
14.56 (369.8)
22.63 (574.7)
14.81 (376.0)
22.88 (581.0)
5.74 (145.7)
8.75 (222.2)
5.82 (147.8)
8.83 (224.2)
7.57 (192.3)
10.88 (276.3)
7.76 (197.1)
11.14 (282.9)
8.01 (203.4)
11.39 (289.2)
0.664 (16.87)
1.097 (27.86)
Dimensions are in inches (millimeters).
11/2-in. (40 mm)
28.44 (722.4)
28.52 (724.4)
30.82 (782.9)
31.06 (789.0)
31.38 (797.1)
11.91 (302.6)
11.99 (304.6)
14.29 (363.1)
14.53 (369.2)
14.85 (377.2)
1.567 (39.80)
(1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm).
www.rosemount.com
69
Rosemount 3051
February 2013
Standard 3051L Dimensional Drawings
2-in. Flange Configuring (Flush Mount Only)
3- and 4-in. Flange Configuration
4.1 (104)
4.1 (104)
Housing
Rotation
Set
Screw
E
D
A
A
2-in., 4-in.,
or 6-in. Extension
(50.8, 101.6, or 152.4)
H
Optional Flushing Connection Ring (Lower
Housing)
G
H
5.13
(130)
4.29
(109)
F
E
6.6
(168)
7.0
(179)
Flushing Connection
8.2
(209)
Diaphragm Assembly and
Mounting Flange
B
C
Dimensions are in inches (millimeters)
70
www.rosemount.com
February 2013
Rosemount 3051
Enhanced 3051 Dimensional Drawings
Enhanced 3051C Exploded View
F(1)
E
D
C
B
A
G
H
I
J
K
N
L
O
M
P
Q
1) Local Configuration Buttons are optional on the enhanced 3051, and can be ordered as Analog Zero and Span, Digital Zero or LOI buttons.
Enhanced 3051C Exploded View labels
A. Cover
B. Cover O-ring
C. Terminal Block
D. Electronics Housing
E. Configuration Buttons Cover
F. Local Configuration Buttons
www.rosemount.com
G. Electronics Board
H. Name Plate
I. Housing Rotation Set Screw (180 degree
maximum rotation without further
disassembly)
J. Sensor Module
K. Coplanar Flange
L. Drain/Vent Valve
M. Flange Adapters
N. Process O-Ring
O. Flange Adapter O-Ring
P. Flange Alignment Screw (not pressure
retaining)
Q. Flange Bolts
71
Rosemount 3051
February 2013
Enhanced 3051C Coplanar Flange
4.29[109]
4.1 (105)
8.2 (209)
6.4 [163]
Enhanced 3051C Coplanar Flange with Rosemount 305 3-Valve Coplanar Integral Manifold
7.54 (192)
10.60 (270)
Max Open
5.5 (140)
Max Open
Dimensions are in inches (millimeters)
72
www.rosemount.com
February 2013
Rosemount 3051
Coplanar Flange Mounting Configurations with
Optional Bracket (B4) for 2-in. Pipe or Panel Mounting
PANEL MOUNTING
PANEL MOUNTING
5
2.8 (71)
/16 ⫻ 11/2 Bolts
for Panel Mounting
(Not Supplied)
3
/8–16 × 11/4 Bolts
for Mounting
to Transmitter
6.20
[157]
2.81
[71]
3.4 (85)
4.73[120]
PIPE MOUNTING
2-inch U-Bolt
for Pipe Mounting
6.25 [159]
3.50 [89]
Dimensions are in inches (millimeters)
www.rosemount.com
73
Rosemount 3051
February 2013
Enhanced 3051C Coplanar with Traditional Flange
4.09[104]
1.63 (410)
DRAIN/VENT
VALVE
1.16
[29]
3.40
[86]
1.10
[28]
FLANGE ADAPTERS
(OPTIONAL)
2.13
(54)
Enhanced 3051C Coplanar with Rosemount 305 3-Valve Traditional Integral Manifold
6.25
(159)
1
/2–14 NPT
Flange
Adapter
(Optional)
Drain/
Vent
Valve
3.63
(92)
1.1
(28
3.5
(87)
1.1
(28)
6.2 (158)
Max Open
2.13
(54)
8.9
(266)
2.7 (69)
Max Open
Dimensions are in inches (millimeters)
74
www.rosemount.com
February 2013
Rosemount 3051
Traditional Flange Mounting Configurations with
Optional Brackets for 2-in. Pipe or Panel Mounting
Panel Mounting Bracket (option B2/B8)
2-in. Pipe Mounting Bracket (option B1/B7/BA)
9.27[235]
2.62[67]
2.62
[67]
6.65
[169]
5
/16 x 7/8 Bolts for Panel
Mounting (Not Supplied)
.93
[24]
4.12
[105]
2.81(71)
PANEL MOUNTING
BRACKET
PIPE MOUNTING
BRACKET
2-in. Pipe Mounting Bracket (option B3/B9/BC)
6.65
[169]
4.85
[123]
1.10
[28]
3.40
[86]
1.75
[44]
Dimensions are in inches (millimeters)
www.rosemount.com
75
Rosemount 3051
February 2013
Enhanced 3051T Dimensional Drawings
4.1 [105]
CERTIFICATION
LABEL
4.29[109]
TRANSMITTER
ELECTRONICS
(THIS SIDE)
FIELD TERMINALS
(THIS SIDE)
7.22
[183]
CONDUIT CONNECTION
(2 PLACES)
NAMEPLATE
HOUSING ROTATION
SET SCREW
1/4-18 NPT FEMALE OR 1/2-14 NPT FEMALE
(SEE SHEET 2 FOR OTHER OPTIONS)
Enhanced 3051T with Rosemount 306 2-Valve I Integral Manifold
4.85
(123)
4.1
(105)
6.25
(159)
Dimensions are in inches (millimeters)
76
www.rosemount.com
February 2013
Rosemount 3051
Enhanced 3051T Typical Mounting Configurations with Optional Mounting Bracket
Pipe Mounting
Panel Mounting
6.15
[156]
2.81
[71]
6.15
[156]
3.49
[89]
4.78
[121]
Dimensions are in inches (millimeters)
www.rosemount.com
77
Rosemount 3051
February 2013
Rosemount Enhanced 3051CFA Pak-Lok Annubar Flowmeter(1)
Front View
Side View
Top View
D
C
B
A
(1) The Pak-Lok Annubar model is available up to 600# ANSI (1440 psig at 100 °F (99 bar at 38 °C)).
Table 23. Enhanced 3051CFA Pak-Lok Annubar Flowmeter Dimensional Data
Sensor Size
A (Max)
B (Max)
C (Max)
D (Max)
1
2
3
8.50 (215.9)
11.0 (279.4)
12.00 (304.8)
14.60 (370.8)
16.35 (415.3)
19.10 (485.1)
9.00 (228.6)
9.00 (228.6)
9.00 (228.6)
6.00 (152.4)
6.00 (152.4)
6.00 (152.4)
Dimensions are in inches (millimeters)
78
www.rosemount.com
February 2013
Rosemount 3051
Rosemount Enhanced 3051CFC Compact Orifice Flowmeter
Compact Orifice Plate
(Primary Element Type code P)
Conditioning Orifice Plate
(Primary Element Type code C)
Orifice Plate Side View
Orifice Plate Front View
Orifice Plate Top View
Primary
Element Type
A
B
Transmitter Height
C
D
Type P and C
5.62 (143)
Transmitter Height + A
6.27 (159)
7.75 (197) - closed
8.25 (210) - open
6.00 (152) - closed
6.25 (159) - open
Dimensions are in inches (millimeters)
www.rosemount.com
79
Rosemount 3051
February 2013
Rosemount Enhanced 3051CFP Integral Orifice Flowmeter
Side View
Bottom View
Front View
8.8 (223.46)
Dimensions are in inches (millimeters).
Line Size
Dimension
J (Beveled/Threaded pipe ends)
J (RF slip-on, RTJ slip-on, RF-DIN slip on)
J (RF 150#, weld neck)
J (RF 300#, weld neck)
J (RF 600#, weld neck)
K (Beveled/Threaded pipe ends)
K (RF slip-on, RTJ slip-on, RF-DIN slip on)(1)
K (RF 150#, weld neck)
K (RF 300#, weld neck)
K (RF 600#, weld neck)
B.D. (Bore Diameter)
1/2-in. (15 mm)
1-in. (25 mm)
12.54 (318.4)
20.24 (514.0)
12.62 (320.4)
20.32 (516.0)
14.37 (364.9)
22.37 (568.1)
14.56 (369.8)
22.63 (574.7)
14.81 (376.0)
22.88 (581.0)
5.74 (145.7)
8.75 (222.2)
5.82 (147.8)
8.83 (224.2)
7.57 (192.3)
10.88 (276.3)
7.76 (197.1)
11.14 (282.9)
8.01 (203.4)
11.39 (289.2)
0.664 (16.87)
1.097 (27.86)
Dimensions are in inches (millimeters).
11/2-in. (40 mm)
28.44 (722.4)
28.52 (724.4)
30.82 (782.9)
31.06 (789.0)
31.38 (797.1)
11.91 (302.6)
11.99 (304.6)
14.29 (363.1)
14.53 (369.2)
14.85 (377.2)
1.567 (39.80)
(1) Downstream length shown here includes plate thickness of 0.162-in. (4.11 mm).
80
www.rosemount.com
February 2013
Rosemount 3051
Enhanced 3051L Dimensional Drawings
2-in. Flange Configuring (Flush Mount Only)
3- and 4-in. Flange Configuration
4.1
(104)
4.1
(104)
E
D
A
A
H
H
2-in., 4-in.,
or 6-in. Extension
(50.8, 101.6, or 152.4
Optional Flushing Connection Ring (Lower
Housing)
5.13
(130)
G
4.29
(109)
F
E
6.6
(168)
Flushing Connection
7.0
(179)
Diaphragm Assembly and
Mounting Flange
B
8.2
(209)
C
Dimensions are in inches (millimeters)
www.rosemount.com
81
Rosemount 3051
February 2013
Table 24. 3051L Dimensional Specifications
Class(1)
ASME B16.5 (ANSI) 150
ASME B16.5 (ANSI) 300
ASME B16.5 (ANSI) 600
DIN 2501 PN 10–40
DIN 2501 PN 25/40
DIN 2501 PN 10/16
Pipe
Size
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
DN 50
DN 80
DN 100
DN 100
Flange
Thickness A
Bolt Circle
Diameter B
Outside
Diameter C
No. of
Bolts
0.69 (18)
0.88 (22)
0.88 (22)
0.82 (21)
1.06 (27)
1.19 (30)
1.00 (25)
1.25 (32)
20 mm
24 mm
24 mm
20 mm
4.75 (121)
6.0 (152)
7.5 (191)
5.0 (127)
6.62 (168)
7.88 (200)
5.0 (127)
6.62 (168)
125 mm
160 mm
190 mm
180 mm
6.0 (152)
7.5 (191)
9.0 (229)
6.5 (165)
8.25 (210)
10.0 (254)
6.5 (165)
8.25 (210)
165 mm
200 mm
235 mm
220 mm
4
4
8
8
8
8
8
8
4
8
8
8
Bolt Hole
Diameter
0.75 (19)
0.75 (19)
0.75 (19)
0.75 (19)
0.88 (22)
0.88 (22)
0.75 (19)
0.88 (22)
18 mm
18 mm
22 mm
18 mm
Extension
Diameter(1) D
O.D. Gasket
Surface E
NA
2.58 (66)
3.5 (89)
NA
2.58 (66)
3.5 (89)
NA
2.58 (66)
NA
66 mm
89 mm
89 mm
3.6 (92)
5.0 (127)
6.2 (158)
3.6 (92)
5.0 (127)
6.2 (158)
3.6 (92)
5.0 (127)
4.0 (102)
5.4 (138)
6.2 (158)
6.2 (158)
Dimensions are in inches (millimeters)
(1) Tolerance are 0.040 (1.02), - 0.020 (0.51)
Class(1)
ASME B16.5 (ANSI) 150
ASME B16.5 (ANSI) 300
ASME B16.5 (ANSI) 600
DIN 2501 PN 10–40
DIN 2501 PN 25/40
DIN 2501 PN 10/16
Pipe
Size
Process
Side F
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
4 (102)
2 (51)
3 (76)
DN 50
DN 80
DN 100
DN 100
2.12 (54)
3.6 (91)
3.6 (91)
2.12 (54)
3.6 (91)
3.6 (91)
2.12 (54)
3.6 (91)
2.4 (61)
3.6 (91)
3.6 (91)
3.6 (91)
Lower Housing G
1
/4-in. NPT
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
0.97 (25)
1
/2 -in. NPT
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
1.31 (33)
H
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
7.65 (194)
7.65 (194)
5.65 (143)
5.65 (143)
5.65 (143)
5.65 (143)
(1) Tolerances are 0.040 (1.02), –0.020 (0.51).
82
www.rosemount.com
February 2013
Rosemount 3051
Commissioning Tag(2)
Options
Standard Configuration
A temporary commissioning tag is attached to all transmitters. The tag
indicates the device ID and allows an area for writing the location.
Unless otherwise specified, transmitter is shipped
as follows:
Optional Rosemount 304, 305 or 306 Integral
Manifolds
ENGINEERING UNITS
Differential/Gage:
Factory assembled to 3051C and 3051T transmitters. Refer to the
following Product Data Sheet (document number 00813-0100-4839 for
Rosemount 304 and 00813-0100-4733 for Rosemount 305 and 306) for
additional information.
Absolute/3051TA:
inH2O (Range 0, 1, 2, and 3)
psi (Range 4 and 5)
psi (all ranges)
4 mA (1):
0 (engineering units above)
20 mA (1):
Upper range limit
Output:
Flange type:
Flange material:
O-ring material:
Drain/vent:
LCD Display:
Linear
Specified model code option
Specified model code option
Specified model code option
Specified model code option
Installed or none
Alarm(1):
Software tag:
High
(Blank)
(1) Not applicable to FOUNDATION fieldbus, PROFIBUS PA, or wireless.
Custom Configuration(1)
If Option Code C1 is ordered, the customer may specify the following
data in addition to the standard configuration parameters.
• Output Information
• Transmitter Information
• LCD Display Configuration
Other Seals
Refer to Product Data Sheet 00813-0100-4016 for additional
information.
Output Information
Output range points must be the same unit of measure. Available units
of measure include:
Pressure
atm
mbar
bar
inH20
inHg
hPa(1)
[email protected] °C(1)
Flow(2)(3)
bbl
ft3
gal
Level(3)
%
in
[email protected] °C(1)
mmH2O
mmHg
[email protected] °C(1)
ftH20
[email protected] °F(1)
Psf(1)
g/cm2
kg/cm2
Pa
kPa
MPa(1)(2)
kg/SqM(1)
[email protected](1)
kg
lb
L
cm3
m3
ton
ft
mm
cm
psi
torr
[email protected] °C(1)
[email protected] °C(1)
[email protected] °F(1)
[email protected] °C(1)
• Hardware Selectable Information
• Signal Selection
• Wireless Information
• Scaled Variable
• and more
Refer to the “Rosemount 3051 Configuration Data Sheet” document
number 00806-0100-4007 for enhanced 3051, or 00806-0100-4001 for
3051.
For Wireless refer to the “Rosemount 3051 Wireless Configuration Data
Sheet” document number 00806-0100-4100.
Tagging (3 options available)
• Standard SST hardware tag is wired to the transmitter. Tag character
height is 0.125 in. (3,18 mm), 56 characters maximum.
• Tag may be permanently stamped on transmitter nameplate upon
request, 56 characters maximum.
• Tag may be stored in transmitter memory. Character limit is
dependent on protocol.
- HART Revision 5: 8 characters
- HART Revision 7 and Wireless: 32 characters
- FOUNDATION fieldbus: 32 characters
- PROFIBUS PA: 32 characters
(1)
Not applicable to FOUNDATION fieldbus or PROFIBUS PA protocols.
www.rosemount.com
(1) Available with enhanced 3051 and Wireless.
(2) Available on PROFIBUS PA.
(3) All flow units are available per second, minute, hour or day.
Display and Interface options
M4
Digital Display with Local Operator Interface (LOI)
• Available for enhanced 4-20 mA HART and PROFIBUS PA
M5 Digital Display
• 2-Line, 5-Digit LCD for standard 4-20 mA HART
• 2-Line, 8-Digit LCD for enhanced 4-20 mA HART, FOUNDATION
fieldbus and PROFIBUS PA
• 3-Line, 7-Digit LCD for Wireless
• Direct reading of digital data for higher accuracy
• Displays user-defined flow, level, volume, or pressure units
• Displays diagnostic messages for local troubleshooting
• 90-degree rotation capability for easy viewing
(2)
Only applicable to FOUNDATION fieldbus.
83
Rosemount 3051
Configuration Buttons(1)
Rosemount 3051 will ship with Analog Zero and Span buttons standard
unless otherwise specified. Enhanced Rosemount 3051 requires option
D4 (Analog Zero and Span), DZ (Digital Zero), or M4 (LOI) for local
configuration buttons.
The Rosemount 3051 Wireless Transmitter is available with a Digital
Zero button installed with or without the LCD digital display.
Transient Protection
T1 Integral Transient Protection Terminal Block
Meets IEEE C62.41, Category Location B
6 kV crest (0.5 s - 100 kHz)
3 kA crest (8 × 20 microseconds)
6 kV crest (1.2 × 50 microseconds)
Bolts for Flanges and Adapters
• Options permit bolts for flanges and adapters to be obtained in
various materials
• Standard material is plated carbon steel per ASTM A449, Type 1
L4 Austenitic 316 Stainless Steel Bolts
L5 ASTM A 193, Grade B7M Bolts
L6 Alloy K-500 Bolts
Conduit Plug
DO 316 SST Conduit Plug
Single 316 SST conduit plug replaces carbon steel plug
February 2013
Rosemount 3051C Coplanar Flange and 3051T Bracket
Option
B4
Bracket for 2-in. Pipe or Panel Mounting
• For use with the standard Coplanar
flange configuration
• Bracket for mounting of transmitter on 2-in. pipe or panel
• Stainless steel construction with stainless steel bolts
Rosemount 3051C Traditional Flange Bracket Options
B1
Bracket for 2-in. Pipe Mounting
• For use with the traditional flange option
• Bracket for mounting on 2-in. pipe
• Carbon steel construction with carbon
steel bolts
• Coated with polyurethane paint
B2 Bracket for Panel Mounting
• For use with the traditional flange option
• Bracket for mounting transmitter on wall
or panel
• Carbon steel construction with carbon
steel bolts
• Coated with polyurethane paint
B3 Flat Bracket for 2-in. Pipe Mounting
• For use with the traditional flange option
• Bracket for vertical mounting of transmitter on 2-in. pipe
• Carbon steel construction with carbon
steel bolts
• Coated with polyurethane paint
B7 B1 Bracket with SST Bolts
• Same bracket as the B1 option with Series 300 stainless steel bolts
B8 B2 Bracket with SST Bolts
• Same bracket as the B2 option with Series 300 stainless steel bolts
B9 B3 Bracket with SST Bolts
• Same bracket as the B3 option with Series 300 stainless steel bolts
BA Stainless Steel B1 Bracket with SST Bolts
• B1 bracket in stainless steel with Series 300 stainless steel bolts
BC Stainless Steel B3 Bracket with SST Bolts
• B3 bracket in stainless steel with Series 300 stainless steel bolts
84
www.rosemount.com
February 2013
www.rosemount.com
Rosemount 3051
85
Rosemount 3051
Product Data Sheet
00813-0100-4801 Rev RA
Emerson Process Management
Rosemount Inc.
8200 Market Boulevard
Chanhassen, MN 55317 USA
T (U.S.) 1-800-999-9307
T (International) (952) 906-8888
F (952) 906 8889
www.rosemount.com
Emerson Process Management Asia
Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
Tel +65 6777 8211
Fax +65 6777 0947
Service Support Hotline : +65 6770 8711
Email : [email protected]
February 2013
Emerson Process Management Latin
America
1300 Concord Terrace, Suite 400
Sunrise Florida 33323 USA
Tel + 1 954 846 5030
Emerson Process Management
Blegistrasse 23
P.O. Box 1046
CH 6341 Baar
Switzerland
Tel +41 (0) 41 768 6111
Fax +41 (0) 41 768 6300
Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.
HART and WirelessHART are registered trademarks of the HART Communication Foundation
All other marks are the property of their respective owners.
© 2012 Rosemount Inc. All rights reserved.
Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement