CV accurate2012 eng 15-10-2012 14:08 Pagina I Close control air conditioning CV accurate2012 eng 15-10-2012 14:08 Pagina II Marketing features The new high-efficiency air conditioner ACCURATE adds the finishing touch to the already prominent presence on the world industrial air-conditioning scenario. It has been designed to satisfy the conditioning requirements of technological rooms, offering features that make it suitable for all the various applications in daily use and from which we demand utmost reliability. CENTRALLY CONTROLLED SYSTEMS - Banks Hotel Airports Retail and distribution industry Museums and Libraries Medium/large companies FINAL APPLICATIONS - Data dispatching nodes Call Centres Data collecting centres Internet centres Global efficiency Outstanding performances Total versatility Intelligent control Total compatibility KEY CUSTOMERS - Railways and motorways Internet providers Armed Forces Public sector Radio and TV companies TELECOM operators CV accurate2012 eng 15-10-2012 14:08 Pagina 1 Index Global efficiency 2-3 Outstanding performances 4-5 Total versatility 6-7 Intelligent control 8-9 Total compatibility 10 - 11 Technical features 12 - 13 AXO / AXU 14 - 15 AWO / AWU 16 - 17 ACO / ACU 18 - 19 ADO / ADU 20 - 21 ATO / ATU 22 - 23 AFO / AFU 24 - 25 ABO / ABU 26 - 27 BRC / BRE / BDC 28 - 29 CV accurate2012 eng 15-10-2012 14:08 Pagina 2 Global efficiency 4 14 3 2 1 13 9 8 11 10 12 2 7 6 5 CV accurate2012 eng 15-10-2012 14:08 Pagina 3 Close air-conditioning means not only compliance with the severest environmental parameters but also with the specific requirements of the site, such as EFFICIENCY, FLEXIBILITY, OPERATING RELIABILITY AND RESPECT FOR THE ENVIRONMENT, which today’s products must satisfy. ACCURATE has been created to meet all these requirements, exploiting the renowned capacity to supply total quality airconditioning systems EFFICIENCY MOST OF ALL COOLING? SENSIBLE! Nowadays efficiency is no longer considered as just energy saving in respect of the single unit, but takes into account both the PERFORMANCE of the whole system and its COMPLETE RELIABILITY and MODULARITY over the years. As is known, electronic equipment develops solely SENSIBLE heat loads and therefore needs dedicated air conditioning to deal with this. In offering ACCURATE as a solution to technological cooling problems, we have been concentrated on the use of known quality parts and integration with BMS (building management systems). Standard solutions - SCROLL compressors - Thermostat valve with internal pressure equalisation - Electronic thermostat (optional) - Standard centrifugal fans - High efficiency EC INVERTER ventilation (optional) - Standard condensation control (DX versions) - Electric reheat or with hot water - Immersed electrode humidifying system - Intelligent dehumidifying system with constant airflow - Semi-graphic control display - Connection to traditional BMS That is why ACCURATE has been made; to ensure maximum SENSIBLE cooling capacity to the detriment of the LATENT capacity, which would be a sheer waste of energy in these applications. This is of basic importance for transforming all the supplied energy into a real room temperature control. The result is a high SHR, minimum of 0.9 and a maximum of 1, in order to have the utmost SENSIBLE and not latent type of cooling. 5% 40% 95% SHR for TECHNOLOGICAL application 60% SHR for COMFORT application 1 MAIN BOARD 8 SIGHT GLASS 2 MAIN SWITCH 9 THERMOSTATIC VALVE 3 HEATERS 10 HUMIDIFIER 4 INVERTER EC FANS 11 DEHUMIDIFICATION VALVE 5 COMPRESSOR 12 HOT WATER VALVE 6 DRIER FILTER 13 TEMP. & HUMIDITY SENSOR 7 LIQUID LINE VALVE 14 USER TERMINAL 3 CV accurate2012 eng 15-10-2012 14:08 Pagina 4 Outstanding performances 4 CV accurate2012 eng 15-10-2012 14:08 Pagina 5 EC INVERTER FANS TECHNOLOGY EC INVERTER FANS This new technology with electronically commutated motor increases the efficiency of the ACCURATE system, optimising running costs through state-of-the-art electronics, which are used to change parameters such as: flow rate cooling capacity external pressure noise leve thereby guaranteeing best operation of the system at any moment, and in particular: 1 Continuous adjustment of the quantity of air € 2.000 2 Intelligent and low-noise system of air conveyance throughout the whole appliance 0,08 euro/kW 0,10 euro/kW € Energy saving (year euro) - The most advanced solution for energy saving € 1.800 1.600 1.400 € € € 1.200 0,05 euro/kW € € 1.000 € 800 600 400 Centrifugal Plug in fans EC FANS 3 Up to 45% saving in the chilled water units Energy saving by EC INVERTER Fans Vs. standard traditional fans DIRECT EXPANSION RANGE THE SPACE IS ALL FOR YOU Cooling Capacity (kW) It is a known fact that the set loads (W/m2) in technological applications are continuously increasing. This is mainly due to the increase in data traffic, giving rise to new equipment with an increasingly greater capacity of transmission, which in turn develops a higher heat load to be dispersed. kW / m2 This requires ever better performance from the airconditioning system that should, however, take up as little space as possible, leaving it for the transmission equipment. kW / m2 45,0 40,0 35,0 30,0 25,0 20,0 15,0 10,0 5,0 0,0 33,3 10 36,0 37,3 18 29 ACCURATE is the air-conditioner with the best SUPPLIED POWER / FOOT PRINT ratio in the market. Because space means value. 40,9 42,5 50 70 Models CHILLED WATER RANGE Cooling Capacity (kW) kW / m2 kW / m2 45,0 40,0 35,0 30,0 25,0 20,0 15,0 10,0 5,0 0,0 31,9 09 39,7 38,0 19 29 42,5 44,0 50 70 Models 5 CV accurate2012 eng 15-10-2012 14:08 Pagina 6 Total versatility All-round flexibility seen as a service offered for any type of system. ACCURATE comes with capacities from 7 to 100 kW in the direct expansion version with air cooling (AXO-AXU) and water cooling (AWO-AWU), from 7 to 221 kW in the TYPES OF COOLING AXO/AXU DIRECT EXPANSION AIR COOLED Refrigerant for heat transfer is used in these direct expansion units. The air in the room is therefore treated in the evaporating coil containing the refrigerant. The condensation heat is dispersed to a fresh air condenser that comes in the standard supply with speed control to optimise the condensation pressure even in adverse temperature conditions. AWO/AWU DIRECT EXPANSION WATER COOLED Refrigerant for heat transfer is used in these direct expansion units. The air in the room is therefore treated in the evaporating coil containing the refrigerant. The condensation heat is dispersed in an internal plate-type exchanger connected in turn to a water circuit. The water of condensation may come from a well, local water mains or closed circuits such as cooling towers or dry coolers. NB: for negative External T values antifreeze fluids must be used to protect the system ACO/ACU CHILLED WATER Water coming generally from a chiller is used in these units to transfer the heat. The flow of liquid through the unit water coil is controlled through an internal 2 or 3-way valve. NB: for negative External T values antifreeze fluids must be used to protect the system AIRFLOW CONFIGURATION OVER The versions called OVER with air outflow from the top generally have the air intake at the front, rear or bottom of the unit, according to customer choice, and the outflow from the top is along ducts behind suspended ceilings or front delivery plenums. 6 OVER unit with front intake and top delivery OVER unit with underfloor intake and top delivery OVER unit with rear intake and top delivery CV accurate2012 eng 15-10-2012 14:09 Pagina 7 chilled water version (ACO-ACU) to be connected to chillers and from 20 to 145 kW in version dual fluid (ADO-ADU / ATO-ATU), free cooling (AFO-AFU) and dual coil (ABO-ABU). ADO/ADU & ATO/ATU DUAL FLUID These units are per standard provided with a dual cooling systems who never work simultaneously. A PRIMARY circuit, made by a chilled water circuit (CW) generally connected to an external chiller, plus a SECONDARY circuit in direct expansion (DX) who is considered as BACK-UP. Such units are particulary indicated anywhere RELIABILITY, SAFETY and REDUNDANCY are required. Units provided per standard with EC inverter fans who represents today the best solution for energy saving. AFO/AFU FREE COOLING These units are per standard provided with a dual cooling systems who are often working simulateusly along the year. A PRIMARY direct expansion circuit (DX) plus a SECONDARY chilled water circuit (CW) generally connected to an external dry cooler who is considered as "support" to the primary one. Such units are particulary indicated anywhere EFFICIENCY & ENERGY SAVING are required. Units provided per standard with EC inverter fans who represents today the best solution for energy saving. ABO/ABU DUAL COIL These units are per standard provided with a double chilled water circuit inside, who never work simultaneously. Such circuits are connected to independent water circuit in order to be one in BACK-UP to the other. Such units are particulary indicated anywhere RELIABILITY, SAFETY and REDUNDANCY are required. CW1 CW2 UNDER Units provided per standard with EC inverter fans who represents today the best solution for energy saving. OVER unit with top intake and undefloor delivery The versions called UNDER with air outflow under the floor have the air intake on the top of the unit taking air directly from the environment or through intake ducts or plenums. 7 CV accurate2012 eng 15-10-2012 14:09 Pagina 8 Intelligent control Intelligent heart and soul ACCURATE has an intelligent electronic heart that allows it to keep a constant control over all the operating and environmental parameters of the site. The ACCURATE electronic unit is open and configurable to specific user requirements both in site and particularly in the factory with dedicated customisation. ELECTRONICS STANDARD FUNCTIONS MAIN OPTIONS Semi-graphic display 132 x 64 pixel Serial cards for BMS interconnection Programmable software Clock card ICONS Graphic Display Fire-smoke alarms Record storage of 100 alarms Flooding alarm General alarm Electronic thermostat control Automatic reset after blackout Flow rate modulation Compressor FIFO management Emergency function Integral LAN system Free Cooling, Dual Fluid and Dual Coil management Standby management Automatic rotation Serious alarms 8 CV accurate2012 eng 15-10-2012 14:09 Pagina 9 OPTIONS AND MAIN ACCESSORIES STANDARD OPTIONALS Structure - Multi-speed centrifugal fans - High efficiency Copeland Scroll compressors - High and low side pressure switches - Filters EU2 - EU4 - R-407C - R-410A Refrigerant - 3-way valves (CW) Structure - EC INVERTER RADIAL-BLADE fans - Immersed electrode humidifiers - Electric reheat and hot water - Intelligent dehumidifying with constant air flow - FILTER F5-F6-F7-F8 (built into the structure) - Air distribution plenum with grilles - Soundproofed plenum - CLASS 0 insulating panels - Electronic thermostat - Condensing control Electronic unit - Semi-graphic display 132 x 64pixel - LAN, integral Local Area Network - Record 100 alarms Electronic unit - Serial cards for BMS interfacing - DC INVERTER FAN control software - Driver for electronic thermostat control 9 CV accurate2012 eng 15-10-2012 14:09 Pagina 10 Total compatibility ACCURATE IS TOTAL COMMUNICATION In a policy of “total communication” ACCURATE offers various solutions for interconnection to the most modern BMSs, aimed at satisfying varying needs. ADVANCED SUPERVISION solutions of compatibility for all the most common BMSs available on the market today, such as: GLOBAL SUPERVISION firmware protocol for total management of all the airconditioning parameters, including: - Detection and transmission of alarms from remote Change of data from remote Recording of data and alarms Sending of SMS via GSM modem all through dedicated serial cards and supervision systems both in LOCAL and REMOTE mode. 10 - MODBUS METASYS LON TREND LONWORKS SNMP/TCPIP to satisfy every single customer requirement and to offer the possibility of communicating with the global network. CV accurate2012 eng 15-10-2012 14:09 Pagina 11 RESPECT FOR THE ENVIROMENT ACCURATE is totally in line with the known policy of full respect for the environment in which we live and for human health and safety. The use of recyclable materials and eco-compatible refrigerants (R407C - R410A) to current standards and legislation, make ACCURATE a state-of-the-art product in this sense. NOISELESS COLD Modern telephone applications in residential areas must satisfy increasingly severer requirements in terms of noise pollution. ACCURATE then propose a large range to satify such requests, often customized base on customer requests and site conditions. Main systems are: - MAINTENANCE The design of the new ACCURATE models was based on the need to simplify routine and extraordinary maintenance work carried out during the lifetime of the product. The refrigerant circuit area is completely separate from the fan area, thereby allowing routine maintenance to be carried out also with the unit in operation. All servicing operations, even the most critical ones, can be accomplished by a full front access. That is why all the front panels are openable and can even be removed thanks to simple hinges. Centrifugal fans (STD) EC INVERTER FANS (OPT) with air flow modulation capability Soundproofed compressors (OPT) Panelling clad in soundproofing material (STD) 11 CV accurate2012 eng 15-10-2012 14:09 Pagina 12 Technical features 12 CV accurate2012 eng 15-10-2012 14:09 Pagina 13 TECHNICAL FEATURES AXO / AXU AWO / AWU ACO / ACU ADO / ADU ATO / ATU AFO / AFU ABO / ABU BRC / BRE / BDC 13 CV accurate2012 eng 15-10-2012 14:09 Pagina 14 TECHNICAL FEATURES AXO / AXU 07÷90 AXO / AXU Close control air conditioner Type: DIRECT EXPANSION, AIR COOLED, upflow or downflow version Evolution Available Versions BASIC Cooling only without condensation control device MOD Cooling only with condensation control device through external unit fans regulation LT Low temperatures version (-45°C) with condensation control device through external unit speed regulation. UNIT DESCRIPTION Ductable close control air-conditioners with capacities ranging from 7 to 90 kW for vertical installation and cooling only, with optional heating by means of heating element or hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air-conditioning technological, server and CED rooms and all technological applications in general. Units fitted with centrifugal fans with airflow from the top & from bottom. External air condenser. Power supply 400/3N/50 (all models). STANDARD UNIT COMPOSITION Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability and functionality of the compressor and all the other components are guaranteed by partners who are world leaders in their sector. Double-inlet centrifugal fan units, directly coupled and suspended on vibration-isolation mountings. The fans are of the forward-bladed type for maximum efficiency and low noise. Condensation control for maximum low noise (standard). 14 Standard G4 filtering section, F5-F8 optional, under CENEN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls the compressor activation times with FIFO logic, thereby regulating the cooling capacity; it also controls the operating alarms with the possibility of interfacing to supervisor and remote-servicing systems. Electrical box under IEC 204-1/EN60204-1 rules. Refrigerant circuit consisting in the standard version of a thermostat with external valve for internal pressure relief, solenoid valve, high/low pressure safety pressure switch, liquid indicator light and dehydrating filter. CV accurate2012 eng 15-10-2012 14:09 Pagina 15 Model 07 10 Frames 15 18 F1 Power supply 20 F2 26 29 39 30 40 F3 50 55 F4 V/Ph/Hz 60 70 80 90 F5 F6 400/3N/50 Refrigerant R410A COOLING PERFORMANCES TOTAL Cooling Capacity (1) kW 7,2 9,6 16,3 19,1 23,3 28,9 31,8 41 33,4 46,2 52,3 60,3 68,1 73,2 87,8 95,4 SENSIBLE Cooling Capacity (1) kW 7,2 9,2 16,3 18,2 23,3 28,8 29,9 41 33,4 46,2 49,9 60,3 68,1 70,1 87,8 91,8 SHR (1) 1,00 0,96 1,00 0,95 1,00 1,00 0,94 1,00 1,00 1,00 0,95 1,00 1,00 0,96 1,00 0,96 2 2 2 2 2 2 2 COMPRESSORS Quantity Power abs. kW Circuits 1 1 1 1 1 1 1 1 2 1,69 2,20 3,64 4,31 4,93 6,00 6,93 7,86 7,26 1 1 1 1 1 1 1 1 2 Refrigerant 9,85 12,02 12,02 13,86 15,69 17,70 21,34 2 2 2 2 2 2 2 R407C COOLING PERFORMANCES TOTAL Cooling Capacity (2) kW 7,9 10,1 16,1 19,3 23,7 29,0 31,7 42,5 34,0 46,9 53,4 62,3 69,7 74,2 86,5 96,7 SENSIBLE Cooling Capacity (2) kW 7,9 9,4 16,1 18,2 23,5 28,8 29,8 42,5 34,0 46,3 50,3 62,3 68,7 70,5 86,5 92,3 SHR (2) 1,00 0,93 1,00 0,94 0,99 0,99 0,94 1,00 1,00 0,99 0,94 1,00 0,99 0,95 1,00 0,95 2 2 2 2 2 2 2 COMPRESSORS Quantity Power abs. kW Circuits 1 1 1 1 1 1 1 1 2 1,84 2,41 3,89 4,46 5,13 6,39 7,32 8,30 7,36 1 1 1 1 1 1 1 1 2 9,68 12,50 12,54 14,67 16,57 18,83 22,49 2 2 2 2 2 2 2 VENTILATION Air flow cbm/h 2500 2500 4900 4900 6500 8000 8000 13500 10500 13500 13500 19000 19000 19000 25000 25000 N° Centrifugal fans 1 1 2 2 1 1 1 2 2 2 2 2 2 2 - - N° EC Inverter fans 1 1 2 2 1 1 1 2 2 2 2 3 3 3 3 3 Centrifugal fans power abs. kW 0,49 0,49 1,00 1,00 1,66 2,02 2,02 3,61 2,89 3,61 3,61 6,55 6,55 6,55 - - EC Inverter fans power abs kW 0,27 0,27 0,53 0,53 0,89 1,69 1,69 3,51 2,09 3,51 3,51 5,11 5,11 5,11 6,1 6,1 50 50 53 53 56 60 60 64 59 64 64 67 67 67 67 67 Sound pressure level (5) dB(A) HUMIDIFIER Steam production Power abs. kg/h 3 3 5 5 5 5 5 5 5 5 5 8 8 8 8 8 kW 2,25 2,25 3,75 3,75 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6 6 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 kW 4 4 8 8 9 9 9 15 15 15 15 18 18 18 18 18 HEATERS Steps Power abs. DIMENSIONS W mm 600 1000 1000 1550 2100 D mm 500 500 790 790 790 2650 790 H mm 1980 1980 1980 1980 1980 1980 NOTE (1) 24°C-50%, 45°C - ESP 20Pa (2) 24°C-50%, 48°C (dew point) - ESP 20Pa (5) Measured at 1,5 m height and 2 m front free field H Coupling D BRE - R410A Indoor unit AX Remote condenser BRE N° 07 10 014m 1 BRC - R407C Indoor unit AX Remote condenser BRC N° 07 10 014m 1 15 022m 1 18 20 027m 1 15 18 025m 1 26 29 044m 1 20 26 032m 1 39 051m 1 29 39 052m 1 30 40 054b 1 50 55 065b 1 60 076b 1 30 40 051b 1 50 55 077b 1 60 088b 1 70 80 0100b 1 70 093b 1 80 102b 1 W 90 116b 1 90 120b 1 ACCESSORIES Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board 15 CV accurate2012 eng 15-10-2012 14:09 Pagina 16 TECHNICAL FEATURES AWO / AWU 07÷90 AWO / AWU Close control air conditioner Type: DIRECT EXPANSION, WATER COOLED, upflow or downflow version Available Versions BASIC Cooling only without condensation control device Evolution MOD_A Cooling only with condensation control device with speed regulation for external unit. For closed circuit installation MOD_B Cooling only with condensation control device with pressostatic valve. For open circuit installation UNIT DESCRIPTION Ductable close control air-conditioners with capacities ranging from 7 to 90 kW for vertical installation and cooling only, with optional heating by means of heating element or hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air-conditioning technological, server and CED rooms and all technological applications in general. Units fitted with centrifugal fans with airflow from the top & from bottom and built-in water-cooled condenser. External dry cooler. Power supply 400/3N/50 (all models). STANDARD UNIT COMPOSITION Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The microprocessor controls the compressor activation times with FIFO logic, thereby regulating the cooling capacity; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. The reliability and functionality of the compressor and all the other components are guaranteed by partners who are world leaders in their sector. Electrical box under IEC 204-1/EN60204-1 rules. Double-inlet centrifugal fan units, directly coupled and suspended on vibration-isolation mountings. The fans are of the forward-bladed type for maximum efficiency and low noise. Condensation control for maximum low noise (standard). 16 Standard G4 filtering section, F5-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. Refrigerant circuit consisting in the standard version of a thermostat with external valve for internal pressure relief, solenoid valve, high/low pressure safety pressure switch, liquid indicator light and dehydrating filter. CV accurate2012 eng 15-10-2012 14:09 Pagina 17 Model 07 10 Frames 15 18 F1 Power supply 20 F2 26 29 39 30 40 F3 V/Ph/Hz 50 55 F4 60 70 80 90 F5 F6 400/3N/50 Refrigerant R410A COOLING PERFORMANCES TOTAL Cooling Capacity (1) kW 7,5 9,8 16,9 19,8 24,5 29,2 33,0 43,0 34,8 48,5 54,5 62,6 70,8 77,4 90,6 99,3 SENSIBLE Cooling Capacity (1) kW 7,5 9,3 16,9 18,3 23,8 28,3 29,9 43,0 34,8 48,4 49,9 62,6 69,1 71,1 90,0 92,8 SHR (1) 1,00 0,95 1,00 0,92 0,97 0,97 0,91 1,00 1,00 1,00 0,92 1,00 0,98 0,92 0,99 0,93 2 2 2 2 2 2 2 COMPRESSORS Quantity Power abs. (1) kW Circuits 1 1 1 1 1 1 1 1 2 1,47 1,91 3,26 3,93 4,28 5,38 6,24 6,91 6,42 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 1 1 8,53 10,76 10,77 12,38 13,54 15,90 19,15 PLATE CONDENSER Quantity 1 1 1 1 1 1 1 Water Flow (1) l/h 1520 2050 3390 4020 4820 5930 6730 Total pressure drops (1) kPa 8 14 5 7 23 30 27 Refrigerant 8360 3460x2 4780x2 5715x2 6155x2 6975x2 7705x2 17850 20160 30 24 21 30 33 30 26 31 39 R407C COOLING PERFORMANCES TOTAL Cooling Capacity (1) kW 7,9 10,3 16,3 19,5 23,9 29,4 32,5 44,6 34,3 47,7 54,8 65,0 72,2 77,2 90,1 100,5 SENSIBLE Cooling Capacity (1) kW 7,9 9,4 16,3 18,2 23,5 28,5 30,3 44,6 34,3 47,6 50,9 65,0 69,7 71,6 89,8 93,8 SHR (1) 1,00 0,91 1,00 0,93 0,98 0,97 0,93 1,00 1,00 1,00 0,93 1,00 0,97 0,93 1,00 0,93 2 2 2 2 2 2 2 COMPRESSORS Quantity Power abs. (1) kW Circuits 1 1 1 1 1 1 1 1 2 1,62 1,83 3,21 3,77 4,28 5,64 6,43 7,24 6,49 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 1 2 2 2 2 2 2 1 1 8,33 11,20 11,28 13,09 14,26 16,87 20,21 PLATE CONDENSER Quantity 1 1 1 1 1 1 1 Water Flow (1) l/h 1620 2190 3350 3980 4720 6090 6880 Total pressure drops (1) kPa 10 17 6 7 22 34 31 8680 3420x2 4690x2 5855x2 6385x2 7145x2 7930x2 18840 20520 35 24 20 32 35 32 31 31 40 VENTILATION Air flow cbm/h 2500 2500 4900 4900 6500 8000 8000 13500 10500 13500 13500 19000 19000 19000 25000 25000 N° Centrifugal fans 1 1 2 2 1 1 1 2 2 2 2 2 2 2 - - N° EC Inverter fans 1 1 2 2 1 1 1 2 2 2 2 3 3 3 3 3 Centrifugal fans power abs. kW 0,49 0,49 1,00 1,00 1,66 2,02 2,02 3,61 2,89 3,61 3,61 6,55 6,55 6,55 - - EC Inverter fans power abs kW 0,27 0,27 0,53 0,53 0,89 1,69 1,69 3,51 2,09 3,51 3,51 5,11 5,11 5,11 6,1 6,1 50 50 53 53 56 60 60 64 59 64 64 67 67 67 67 67 Sound pressure level (5) dB(A) HUMIDIFIER Steam production Power abs. kg/h 3 3 5 5 5 5 5 5 5 5 5 8 8 8 8 8 kW 2,25 2,25 3,75 3,75 3,75 3,75 3,75 3,75 3,75 3,75 3,75 6 6 6 6 6 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 kW 4 4 8 8 9 9 9 15 15 15 15 18 18 18 18 18 HEATERS Steps Power abs. DIMENSIONS W mm 600 1000 1000 1550 2100 D mm 500 500 790 790 790 2650 790 H mm 1980 1980 1980 1980 1980 1980 NOTE (1) Air 24°C-50%, water 30°- 35°C - ESP 20Pa (5) Measured at 1,5 m height and 2 m front free field H Coupling BDC Indoor unit AW Dry cooler BDC N° D 07 10 013m 1 15 18 030m 1 20 26 29 039m 1 39 30 40 50 052m 039m 052m 062m 1 1 1 1 55 60 078m 1 70 92m 1 W 80 90 103m 123m 1 1 ACCESSORIES Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board 17 CV accurate2012 eng 15-10-2012 14:09 Pagina 18 TECHNICAL FEATURES ACO / ACU 07÷221 ACO / ACU Close control air conditioner Type: CHILLED WATER, upflow or downflow version Evolution Available Versions BASIC Cooling only, with 3 way valve HT High temperatures version, with 3 way valve UNIT DESCRIPTION Ductable close control air-conditioners with capacities ranging from 7 to 221 kW for vertical installation and cooling only, with optional heating by means of heating element or hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air-conditioning technological, server and CED rooms and all technological applications in general. Units fitted with centrifugal fans with airflow from the top & from bottom. Unit has to be connected to an external chiller. STANDARD UNIT COMPOSITION Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. Double-inlet centrifugal fan units, directly coupled and suspended on vibration-isolation mountings. The fans are of the forward-bladed type for maximum efficiency and low noise. 18 Standard G4 filtering section, F5-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. Capillary Pre and After sales service. CV accurate2012 eng 15-10-2012 14:09 BASIC Pagina 19 7 9 Frames 14 19 F1 Power supply V/Ph/Hz 25 30 F2 34 41 F3 50 60 70 F4 230/1/50 80 90 F5 131 151 171 F6 191 221 F7 F8 400/3N/50 COOLING PERFORMANCES TOTAL Cooling Capacity (1) kW 8,5 10,1 15,7 20,4 28,4 33,8 37,4 48,5 57,7 69,0 SENSIBLE Cooling Capacity (1) kW 8,5 9,5 15,7 19,0 28,4 30,9 37,4 48,5 52,8 69,0 82,6 88,7 104,3 131,1 154,9 178,2 197,2 224,7 73,7 88,7 97,0 106,1 126,6 136,4 156,0 168,0 SHR (1) 1,00 0,94 1,00 0,93 1,00 0,91 1,00 1,00 0,92 1,00 0,89 1,00 0,93 0,81 0,82 0,77 0,79 0,75 WATER SIDE Water Flow (1) Total pressure drops (1) l/h 1390 1660 2570 3330 4640 5520 6110 7930 9430 11280 13500 14500 17050 21650 25530 29290 32350 36610 kPa 33 36 39 60 57 65 46 69 71 71 73 69 74 122 88 105 147 135 VENTILATION Air flow kPa 2500 2500 4900 4900 8000 8000 13500 13500 13500 19000 19000 25000 25000 25000 30000 30000 36000 36000 N° Centrifugal fans 1 1 2 2 1 1 2 2 2 2 2 3 3 3 - - - - N° EC Inverter fans 1 1 2 2 1 1 2 2 2 3 3 3 3 3 3 3 3 3 Centrifugal fans power abs. kW 0,49 0,49 1,00 1,00 2,02 2,02 3,61 3,61 3,61 6,55 6,55 9,42 9,42 9,42 - - - - EC Inverter fans power abs kW 0,27 0,27 0,53 0,53 1,69 1,69 3,51 3,51 3,51 5,11 5,11 6,1 6,1 6,1 4,90 4,90 6,70 6,70 50 53 53 60 64 64 67 67 67 67 67 69 69 70 70 5 5 8 8 8 8 8 10 10 15 15 3,75 3,75 6 6 6 6 6 7,5 7,5 Sound pressure level (5) dB(A) 50 kg/h 3 60 64 5 5 HUMIDIFIER Steam production Power abs. 3 5 5 5 2,25 3,75 3,75 3,75 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 8 8 9 9 15 15 15 18 18 18 18 18 24 24 24 24 kW 2,25 3,75 3,75 11,25 11,25 HEATERS Steps Power abs. kW DIMENSIONS W mm 600 1000 1000 1550 2100 2650 2650 D mm 500 500 790 790 790 790 890 890 H mm 1980 1980 1980 1980 1980 1980 2180 2180 30 34 HT 25 Frames Power supply v/Ph/Hz 41 50 60 70 3200 80 90 F3 F4 F5 F6 400/3N/50 400/3N/50 400/3N/50 400/3N/50 COOLING PERFORMANCES TOTAL Cooling Capacity (2) kW 30,8 37,1 44,5 52,2 63,2 73,3 87,4 97,4 108 SENSIBLE Cooling Capacity (2) kW 30,8 37,1 44,5 52,2 63,2 73,3 87,4 97,4 108 SHR (2) 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,0 WATER SIDE Water flow (2) l/h 5310 6400 7680 9000 10900 12600 15100 16800 18600 Total pressure drops (2) kPa 21,6 22,6 25,1 18,6 29,0 14,8 8,8 30,4 23,4 mc/h 8000 8000 13500 13500 13500 19000 19000 25000 25000 1 1 2 2 2 2 2 3 3 N° 1 1 2 2 2 3 3 3 3 kW 2,02 2,02 3,61 3,61 3,61 6,55 6,55 9,42 9,42 kW VENTILATION Air flow N° Centrifugal fans N° EC Inverter fans Centrifugal fans power abs. EC Inverter fans power abs Sound pressure level (5) 1,69 1,69 3,51 3,51 3,51 5,11 5,11 6,10 6,10 dB(A) 60 60 64 64 64 67 67 67 67 kg/h 5 5 5 5 5 8 8 8 8 kW 4 4 4 4 4 6 6 6 6 3 3 3 3 3 3 3 3 3 9 9 15 15 15 18 18 18 18 HUMIDIFIER Steam production Power abs. HEATERS Steps Power abs. kW DIMENSIONS W mm 1000 1550 2100 D mm 790 790 790 790 H mm 1980 1980 1980 1980 (1) Water 7-12 °C; air 24°C-50% - ESP 20Pa (2) Water 15-20 °C; air 33°C/40% - ESP 20Pa 2650 (5) Measured at 1,5 m height and 2 m front free field ACCESSORIES Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings H Air distribution plenum Sound absorber plenum for air outlet Interface electronic board 3 way valve 0÷10 V D W 19 CV accurate2012 eng 15-10-2012 14:09 Pagina 20 TECHNICAL FEATURES ADO / ADU 20÷90 ADO / ADU Close control air conditioner Type: DUAL FLUID, AIR COOLED, upflow or downflow version Evolution Available Versions BASIC Cooling only without condensation control device MOD Cooling only with condensation control device through external unit fans regulation LT Low temperatures version (-45°C) with condensation control device through external unit speed regulation. UNIT DESCRIPTION Ductable close control units air-conditioners with capacity ranging from 20 to 90 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifer and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fittend with EC INVERTER fans, upflow or downflow. Units has to be connected to an external chiller for PRIMARY circuit instead to an air cooled condenser for the SECONDARY circuit (BACK-UP circuit). STANDARD UNIT COMPOSITION Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. 20 Standard G4 filtering section, F5-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. CV accurate2012 eng 15-10-2012 Model Frames Power supply Refrigerant COOLING PERFORMANCES (DX) TOTAL Cooling Capacity SENSIBLE Cooling Capacity SHR COMPRESSORS Quantity Power abs. Circuits Refrigerant COOLING PERFORMANCES (DX) TOTAL Cooling Capacity SENSIBLE Cooling Capacity SHR COMPRESSORS Quantity Power abs. Circuits COOLING PERFORMANCES (CW) TOTAL Cooling Capacity SENSIBLE Cooling Capacity SHR WATER SIDE Water Flow Total pressure drops VENTILATION Air flow N° EC Inverter fans EC Inverter fans power abs Sound pressure level HUMIDIFIER Steam production Power abs. HEATERS Steps Power abs. DIMENSIONS W D H 14:09 Pagina 21 20 26 F3 29 39 23,7 21,8 0,92 29,4 27,9 0,95 32,7 30,2 0,92 42,2 42,2 1,00 36,7 36,2 0,99 47,6 47,0 0,99 55,1 50,7 0,92 62,1 62,1 1,00 75,5 71,0 0,94 86,3 86,1 1,00 98,8 91,0 0,92 1 4,93 1 1 6,01 1 1 6,75 1 1 7,87 1 2 2 7,15 9,87 2 2 R407C 2 11,70 2 2 12,02 2 2 15,40 2 2 17,68 2 2 21,38 2 23,2 22,2 0,96 30,1 28,1 0,93 32,9 30,3 0,92 43,8 43,8 1,00 36,2 36,0 0,99 46,7 46,6 1,00 55,3 50,9 0,92 64,2 64,2 1,00 77,5 71,8 0,93 90,8 87,9 0,97 99,9 91,4 0,91 1 4,85 1 1 6,26 1 1 7,15 1 1 8,30 1 2 7,41 2 2 9,70 2 2 12,20 2 2 12,55 2 2 16,30 2 2 18,84 2 2 22,51 2 V/Ph/Hz (1) (1) kW kW kW (2) (2) kW kW kW 30 40 F4 400/3N/50 R410A 50 60 70 80 90 F5 F6 (4) (4) kW kW 23,8 21,8 0,92 28,1 26,4 0,94 29,5 27,6 0,94 50,0 46,3 0,93 41,0 37,0 0,90 50,0 46,3 0,93 51,4 47,5 0,92 65,0 62,2 0,96 67,6 64,5 0,95 91,0 85,0 0,93 91,0 85,0 0,93 (4) (4) l/h kPa 3890 26 4590 35 4590 35 8170 46 6710 30 8170 46 8170 46 10630 26 10630 26 14870 53 14870 53 cbm/h kW dB(A) 6000 1 0,89 56 7500 1 1,60 60 8000 1 1,80 60 13000 2 3,40 64 10000 2 2,09 59 13000 2 3,40 64 13500 2 3,65 64 18000 3 4,50 67 19000 3 5,20 67 24000 3 6,1 67 24000 3 6,1 67 kg/h kW 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 8 6 8 6 8 6 8 6 kW 3 9 3 9 3 9 3 15 3 15 3 15 3 15 3 18 3 18 3 18 3 18 (5) mm mm mm 1000 790 1980 1550 790 1980 2100 790 1980 2650 790 1980 NOTE (1) 24°C-50%, 45°C - ESP 20Pa (2) 24°C-50%, 48°C (dew point) - ESP 20Pa (4) Air 24°C-50%, water 7-12 °C - ESP 20Pa (5) Measured at 1,5 m height and 2 m front free field H Coupling BRE - R410A Indoor unit AD Remote condenser BRE N° BRC - R407C Indoor unit AD Remote condenser BRC N° D 20 027m 1 26 20 26 29 044m 1 032m 1 39 051m 1 30 39 30 29 052m 1 40 054b 1 40 051b 1 50 065b 1 60 076b 1 70 50 077b 1 60 088b 1 70 093b 1 80 90 116b 1 80 102b 1 90 120b 1 100b 1 W ACCESSORIES Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board 21 CV accurate2012 eng 15-10-2012 14:09 Pagina 22 TECHNICAL FEATURES ATO / ATU 20÷90 ATO / ATU Close control air conditioner Type: DUAL FLUID, WATER COOLED, upflow or downflow version Available Versions BASIC Cooling only without condensation control device Evolution MOD_A Cooling only with condensation control device with speed regulation for external unit. For closed circuit installation MOD_B Cooling only with condensation control device with pressostatic valve. For open circuit installation (well-probe) UNIT DESCRIPTION Ductable close control units air-conditioners with capacity ranging from 20 to 90 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fitted with EC INVERTER fans, upflow or downflow. Units has to be connected to an external chiller for PRIMARY circuit instead to an external dry cooler for the SECONDARY circuit (BACK-UP circuit). STANDARD UNIT COMPOSITION Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. 22 Standard G4 filtering section, F5-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. CV accurate2012 eng 15-10-2012 Model Frames Power supply Refrigerant COOLING PERFORMANCES (DX) TOTAL Cooling Capacity SENSIBLE Cooling Capacity SHR COMPRESSORS Quantity Power abs. Circuits PLATE CONDENSER Quantity Water Flow Total pressure drops Refrigerant COOLING PERFORMANCES (DX) TOTAL Cooling Capacity SENSIBLE Cooling Capacity SHR COMPRESSORS Quantity Power abs. Circuits PLATE CONDENSER Quantity Water Flow Total pressure drops COOLING PERFORMANCES (CW) TOTAL Cooling Capacity SENSIBLE Cooling Capacity SHR WATER SIDE Water Flow Total pressure drops VENTILATION Air flow N° EC Inverter fans EC Inverter fans power abs Sound pressure level HUMIDIFIER Steam production Power abs. HEATERS Steps Power abs. DIMENSIONS W D H 14:09 Pagina 23 20 26 F3 29 39 24,9 22,8 0,92 30,6 28,3 0,92 32,3 30,0 0,93 47,3 46,9 0,99 38,1 36,7 0,96 50,0 47,9 0,96 54,5 50,7 0,93 70,3 66,8 0,95 76,6 71,1 0,93 91,8 88,2 0,96 101,9 92,2 0,90 1 4,30 1 1 5,40 1 1 6,11 1 1 6,94 1 2 6,44 2 2 8,61 2 2 10,55 2 2 12,28 2 2 13,30 2 2 16,03 2 2 19,33 2 1 4900 24 1 6330 32 1 7002 28 1 8430 31 2 5977x2 32 2 7180x2 30 2 8066x2 28 1 18120 33 1 20830 41 24,2 22,6 0,93 31,3 28,6 0,91 32,5 30,2 0,93 45,9 45,9 1,00 37,6 36,5 0,97 49,0 47,5 0,97 54,7 50,8 0,93 71,7 67,3 0,94 77,6 71,3 0,92 92,8 88,5 0,95 101,0 91,9 0,91 1 4,53 1 1 5,96 1 1 6,64 1 1 7,66 1 2 7,05 2 2 8,85 2 2 11,55 2 2 13,4 2 2 14,78 2 2 17,83 2 2 21,35 2 1 4780 22 1 6190 35 1 7204 32 1 9650 36 2 3720x2 26 2 4805x2 22 2 6156x2 33 2 7370x2 36 2 8340x2 32 1 19160 32 1 21340 40 V/Ph/Hz 30 40 F4 400/3N/50 R410A 50 60 70 80 90 F5 F6 (1) (1) (1) kW kW (1) kW (1) (1) l/h kPa (1) (1) (1) kW kW (1) kW (1) (1) l/h kPa (6) (6) kW kW 23,8 21,8 0,92 28,1 26,4 0,94 29,5 27,6 0,94 50,0 46,3 0,93 41,0 37,0 0,90 50,0 46,3 0,93 51,4 47,5 0,92 65,0 62,2 0,96 67,6 64,5 0,95 91,0 85,0 0,93 91,0 85,0 0,93 (6) (6) l/h kPa 3890 26 4590 35 4590 35 8170 46 6710 30 8170 46 8170 46 10630 26 10630 26 14870 53 14870 53 cbm/h kW dB(A) 6000 1 0,89 56 7500 1 1,60 60 8000 1 1,80 60 13000 2 3,40 64 10000 2 2,09 59 3000 2 3,40 64 13500 2 3,65 64 18000 3 4,50 67 19000 3 5,20 67 24000 3 6,1 67 24000 3 6,1 67 kg/h kW 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 8 6 8 6 8 6 8 6 kW 3 9 3 9 3 9 3 15 3 15 3 15 3 15 3 18 3 18 3 18 3 18 (5) mm mm mm 2 2 3690 x 2 4905 x 2 27 21 R407C 1000 790 1980 1550 790 1980 2100 790 1980 2650 790 1980 NOTE (1) Air 24°C-50%, water 30°- 35°C - ESP 20Pa (5) Measured at 1,5 m height and 2 m front free field (6) Air 24°C-50%, water 7-12 °C - ESP 20Pa H Coupling BDC Indoor unit AT Dry cooler BDC N° D 20 030m 1 26 29 039m 1 39 052m 1 30 039m 1 40 052m 1 50 062m 1 60 078m 1 70 092m 1 80 103m 1 W 90 123m 1 ACCESSORIES Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board 23 CV accurate2012 eng 15-10-2012 14:09 Pagina 24 TECHNICAL FEATURES AFO / AFU 20÷90 AFO / AFU Close control air conditioner Type: FREECOOLING, WATER COOLED, upflow or downflow version Evolution Available Versions BASIC Cooling only with condensation control device through flooding valve MOD_A Cooling only with condensation control device through flooding valve and speed regulator for external unit UNIT DESCRIPTION Ductable close control units air-conditioners with capacity ranging from 20 to 90 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fitted with EC INVERTER fans, upflow or downflow. Units has to be connected to an external chiller or dry cooler STANDARD UNIT COMPOSITION Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. 24 Standard G4 filtering section, F5-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. CV accurate2012 eng 15-10-2012 14:09 Model Frames Power supply V/Ph/Hz Refrigerant COOLING PERFORMANCES (DX) TOTAL Cooling Capacity (1) kW SENSIBLE Cooling Capacity (1) kW SHR COMPRESSORS Quantity Power abs. kW Circuits PLATE CONDENSER Quantity Condensation water flow (1) l/h Pressure drop DX operation Refrigerant COOLING PERFORMANCES (DX) TOTAL Cooling Capacity (1) kW SENSIBLE Cooling Capacity (1) kW SHR COMPRESSORS Quantity Power abs. kW Circuits PLATE CONDENSER Quantity Condensation water flow (1) l/h Pressure drop DX operation kPa COOLING PERFORMANCES IN FREE-COOLING TOTAL Cooling Capacity (2) kW SENSIBLE Cooling Capacity (2) kW SHR Pressure drop FC operation kPa VENTILATION Air flow cbm/h N° EC Inverter fans EC Inverter fans power abs kW Sound pressure level (5) dB(A) HUMIDIFIER Steam production kg/h Power abs. kW HEATERS Steps Power abs. kW DIMENSIONS W mm D mm H mm Pagina 25 20 26 F3 29 39 30 40 F4 400/3N/50 R410A 24,9 22,8 0,92 30,6 28,3 0,92 32,3 30,0 0,93 47,3 46,9 0,99 38,1 36,7 0,96 50,0 47,9 0,96 54,5 50,7 0,93 70,3 66,8 0,95 76,6 71,1 0,93 91,8 88,2 0,96 101,9 92,2 0,90 1 4,40 1 1 5,40 1 1 6,11 1 1 8,00 1 2 6,44 2 2 8,61 2 2 10,55 2 2 12,28 2 2 13,30 2 2 16,03 2 2 19,33 2 1 4900 47 1 6330 70 1 7002 46 1 8430 66 2 2 7380 9810 49 56 R407C 2 11954 55 2 14360 65 2 16133 70 1 18120 55 1 20830 68 24,2 22,6 0,93 31,3 28,6 0,91 32,5 30,2 0,93 45,9 45,9 1,00 37,6 36,5 0,97 49,0 47,5 0,97 54,7 50,8 0,93 71,7 67,3 0,94 77,6 71,3 0,92 92,8 88,5 0,95 101,0 91,9 0,91 1 4,30 1 1 5,66 1 1 6,30 1 1 7,28 1 2 6,70 2 2 8,41 2 2 10,96 2 2 13,40 2 2 14,03 2 2 16,94 2 2 20,28 2 1 4780 45 1 6190 73 1 7204 47 1 9650 67 2 7440 48 2 9610 58 2 12313 57 2 14740 71 2 16680 74 1 19160 60 1 21340 72 19,95 19,95 1 60 24,04 24,04 1 97 25,10 25,10 1 69 40,79 40,79 1 89 33,62 33,62 1 64 41,47 41,47 1 84 43,80 43,80 1 95 56,62 56,62 1 85 58,10 58,10 1 91 76,67 76,67 1 80 78,26 78,26 1 99 6000 1 0,89 56 7500 1 1,60 60 8000 1 1,80 60 13000 2 3,40 64 10000 2 2,09 59 13000 2 3,40 64 13500 2 3,65 64 18000 3 4,50 67 19000 3 5,20 67 24000 3 6,1 67 24000 3 6,1 67 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 5 3,75 8 6 8 6 8 6 8 6 3 9 3 9 3 9 3 15 3 15 3 15 3 15 3 18 3 18 3 18 3 18 1000 790 1980 50 60 70 80 90 F5 1550 790 1980 F6 2100 790 1980 2650 790 1980 NOTE (1) Air 24°C-50%, water 30°- 35°C - ESP 20Pa (2) Water in 10°C, water flow as for DX - ESP 20 Pa (5) Measured at 1,5 m height and 2 m front free field H Coupling BDC Indoor unit AF Dry cooler BDC N° D 20 030m 1 26 29 039m 1 39 052m 1 30 039m 1 40 052m 1 50 062m 1 60 078m 1 70 092m 1 80 103m 1 W 90 123m 1 ACCESSORIES Remote user terminal Electric heating coil Water heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board 25 CV accurate2012 eng 15-10-2012 14:09 Pagina 26 TECHNICAL FEATURES ABO / ABU 20÷140 ABO / ABU Close control air conditioner Type: DUAL COIL, upflow or downflow version Evolution Available Versions BASIC Cooling only, with 3 way valve UNIT DESCRIPTION Ductable close control units air-conditioners with capacity ranging from 20 to 140 kW for vertical installation and cooling only, with optional heating by means of heating elements and hot water, optional humidifier and dehumidifier for precise temperature and humidity control. Particularly suitable for air conditioning technological, servers and IT rooms and all technological applications in general. Units fitted with EC INVERTER fans, upflow or downflow. Units has to be connected to 2 completely independent circuits each one in back-up to the other one. STANDARD UNIT COMPOSITION Unit for installing inside or outside the room to be air-conditioned. Maximum resistance to rust thanks to galvanised sheet metal structures and panels with powder-coated paint finish. The panels are lined with sound-insulating material. The reliability of all the components is guaranteed by partners who are world leaders in their sector. NEW EC INVERTER fans with electronic commutation in order to maximize the energy saving and reducing the noise emissions. 26 Standard G4 filtering section, F5-F8 optional, under CEN-EN 779 rule with the separation degree 90,1% ASHRAE. The filter is autoestinguishing type. The microprocessor controls all the main functions of the air conditioners; it also controls the operating alarms with the possibility of interfacing to supervisor and remoteservicing systems. Electrical box under IEC 204-1/EN60204-1 rules. CV accurate2012 eng 15-10-2012 14:09 Model Pagina 27 20 Frames 25 30 40 F3 Power supply 45 55 F4 60 75 F5 105 120 F6 V/Ph/Hz 130 140 F7 F8 400/3N/50 COOLING PERFORMANCES TOTAL Cooling Capacity (1) kW 22,5 29,0 41,2 50,5 54,2 66,4 76,6 94,3 104,5 124,7 131,3 148,2 SENSIBLE Cooling Capacity (1) kW 22,5 27,7 41,2 47,5 54,2 64,5 76,6 89,9 101,9 111,8 128,2 136,6 SHR (1) 1,00 0,96 1,00 0,94 1,00 0,97 1,00 0,95 0,98 0,90 0,98 0,92 8000 8000 13500 13500 19000 19000 26000 26000 30000 30000 36000 36000 1 1 2 2 3 3 3 3 3 3 3 3 1,69 1,69 3,51 3,51 5,11 5,11 6,1 6,1 4,90 4,90 6,70 6,70 60 60 64 64 67 67 67 67 69 69 70 70 VENTILATION Air flow cbm/h N° EC Inverter fans EC Inverter fans power abs Sound pressure level kW (5) dB(A) Water Flow (1) l/h 3670 4840 6740 8420 8860 11060 12520 15710 17420 20780 21880 24070 Total pressure drops (1) kPa 51 72 42 45 38 53 43 52 95 73 55 66 WATER SIDE HUMIDIFIER Steam production Power abs. kg/h 5 5 5 5 8 8 8 8 10 10 15 15 kW 3,75 3,75 3,75 3,75 6 6 6 6 7,5 7,5 11,25 11,25 3 3 3 3 3 3 3 3 3 3 3 3 9 9 15 15 18 18 18 18 24 24 24 24 HEATERS Steps Power abs. kW DIMENSIONS W mm 1000 1550 2100 2650 2650 3200 D mm 790 790 790 790 890 890 H mm 1980 1980 1980 1980 2180 2180 NOTE (1) Water 7-12 °C; air 24°C-50% - ESP 20Pa (5) Measured at 1,5 m height and 2 m front free field H D W ACCESSORIES Remote user terminal Electric heating coil Humidifier Vibration isolation frame with rubber mountings Air distribution plenum Sound absorber plenum for air outlet Interface electronic board 3 way valve 0÷10 V 27 CV accurate2012 eng 15-10-2012 14:09 Pagina 28 TECHNICAL FEATURES BRC / BRE / BDC BRC (R407C) / BRE (R410A) Air cooled remote condensers with axial fans for direct expansion units BDC Dry Cooler with axial fans Available Versions BASIC standard (+46°C/-25°C, Text.) LN Low Noise (+46°C/-45°C, Text.) Accessories Condenser leg kit for vertical air flow version LT Low temperature (+46°C/-45°C, Text.) BRC STD - LT (R407C) NOMINAL CHARACTERISTICS Nominal capacity Air flow Sound pressure level 10m Power supply DIMENSIONS W D H BRC LN (R407C) NOMINAL CHARACTERISTICS Nominal capacity Air flow Sound pressure level 10m Power supply DIMENSIONS W D H 014m 025m 032m 052m 051b 077b 088b 093b 102b 120b kW kPa dB(A) V-Ph~Hz 14 4410 41,0 26 8780 48,0 32 7870 48,0 52 17560 51,0 52 77 17560 26340 51,0 53,0 230/1/50 90 25230 53,0 93 23610 53,0 102 35120 54,0 120 33640 54,0 mm mm mm 1175 510 872 1325 630 1168 1325 630 1168 2425 630 1168 2425 630 1168 3525 630 1168 3525 630 1168 3525 630 1168 4625 630 1168 4625 630 1168 014m 025m 032m 052m 051b 077b 088b 093b 102b 120b kW kPa dB(A) V-Ph~Hz 13 2930 33 22 6410 38 42 12820 41 48 12160 41 48 72 12160 18240 41 43 230/1/50 76 17340 43 85 25640 44 95 24320 44 101 23400 44 mm mm mm 1175 510 872 1325 630 1168 2425 630 1168 2425 630 1168 2425 630 1168 3525 630 1168 4625 630 1168 4625 630 1168 4625 630 1168 3525 630 1168 W H PACKAGING DIMENSIONS D DIRECT EXSPANSION AXO / AXU Model W D H Weight 07 mm mm mm kg* 10 15 660 18 20 1060 26 1060 29 39 30 40 50 55 1610 560 60 2160 70 80 90 2710 850 2250 162 177 264 276 329 380 398 524 464 18 20 26 1060 29 39 30 519 544 712 758 778 912 40 50 55 60 2160 70 80 787 812 942 DIRECT EXSPANSION AWO / AWU Model W D H Weight 07 mm mm mm kg* 10 15 660 1060 1610 560 90 2710 850 2250 168 184 274 288 341 394 412 543 41 1610 50 482 543 569 740 972 1003 CHILLER WATER ACO / ACU Model W D H Weight 07 mm mm mm kg* 09 14 660 25 30 1060 34 127 137 60 70 80 2160 560 NOTE *Shipping weight (wooden crate non included) 28 19 1060 90 2710 131 151 171 2710 850 208 218 278 293 2250 374 384 394 548 558 634 644 644 659 191 221 3260 950 2450 669 750 800 CV accurate2012 eng 15-10-2012 BRE STD - LT (R410A) NOMINAL CHARACTERISTICS Nominal capacity Air flow Sound pressure level 10m Power supply DIMENSIONS W D H BRE LN (R410A) NOMINAL CHARACTERISTICS Nominal capacity Air flow Sound pressure level 10m Power supply DIMENSIONS W D H BDC STD - LT NOMINAL CHARACTERISTICS Nominal capacity Air flow Sound pressure level 10m Power supply DIMENSIONS W D H BDC LN NOMINAL CHARACTERISTICS Nominal capacity Air flow Sound pressure level 10m Power supply DIMENSIONS W D H 14:09 Pagina III 014m 022m 027m 044m 051m 065m 054b 065b 076b 100b 116b 134b kW kPa dB(A) V-Ph~Hz 13,4 5000 40,0 21,7 8200 46,0 26,6 7200 46,0 43,5 16400 49,0 50,4 15200 49,0 65,1 24600 51,0 230/1/50 53,3 14400 49,0 65,1 24600 51,0 76,2 22800 51,0 100 28800 52,0 116 38000 53,0 134 35850 53,0 mm mm mm 1240 494 764 1360 580 1070 1360 580 1070 2360 580 1070 2360 580 1070 3360 580 1070 2360 580 1070 3360 580 1070 3360 580 1070 4360 580 1070 5360 580 1070 5360 580 1070 014m 022m 027m 044m 051m 065m 054b 065b 076b 100b 116b 134b kW kPa dB(A) V-Ph~Hz 14,1 6000 37,0 20 6500 35,0 28,2 12000 39,0 42,3 18000 41,0 50 16500 41,0 73,1 22000 42,0 230/1/50 55,3 16000 41,0 73,1 22000 42,0 75,5 20300 42,0 99,1 27050 43,0 117,5 28560 43,0 134 28560 43,0 mm mm mm 1360 580 1070 2120 494 764 2360 580 1070 3360 580 1070 3360 580 1070 4360 580 1070 3360 580 1070 4360 580 1070 4360 580 1070 5360 580 1070 5560 615 1070 5560 615 1070 013m 030m 039m 052m 062m 078m 092m 103m 123m kW kPa dB(A) V-Ph~Hz 17 8780 48 33 17560 51 40,5 16820 51 61 25230 53 68 23610 53 230/1/50 83 33640 54 98,5 52680 56 121 50460 56 135 47220 56 mm mm mm 1325 630 1168 2425 630 1168 2425 630 1168 3525 630 1168 3525 630 1168 4625 630 1168 3658 760 2286 3658 760 2286 3658 760 2286 013m 030m 039m 052m 062m 078m 092m 103m 123m kW kPa dB(A) V-Ph~Hz 14 6410 38 32 12160 41 40,5 19230 43 54 25640 44 65,5 24320 44 230/1/50 82 30400 45 96 36480 46 107 51280 47 128,5 48640 47 mm mm mm 1325 630 1168 2425 630 1168 3525 630 1168 4625 630 1168 4625 630 1168 5725 630 1168 3658 760 2286 4758 760 2286 4758 760 2286 W H D DUAL FLUID ADO/ADU Model W D H Weight 20 mm mm mm kg* 26 1060 29 39 30 40 50 60 1610 308 355 373 489 429 20 26 1060 29 39 30 70 80 2160 850 2250 484 509 731 40 50 60 90 2710 751 871 70 80 901 DUAL FLUID ATO/ATU Model W D H Weight mm mm mm kg* 343 1610 394 412 528 468 26 1060 29 39 30 2160 850 2250 523 548 767 40 50 60 90 2710 W 787 908 70 80 938 FREE-COOLING AFO/AFU Model W D H Weight 20 mm mm mm kg* 351 402 1610 412 528 468 2160 850 2250 523 90 2710 H 554 767 779 897 927 DUAL COIL ABO/ABU Model W D H Weight 20 mm mm mm kg* 25 30 1060 40 45 1610 55 60 2160 75 105 2710 120 381 533 533 140 D 3260 850 2250 381 130 2710 950 2450 771 803 806 887 890 947 880 920 29 15-10-2012 14:09 Pagina IV ACCURATE_10-2012_REV04_EN CV accurate2012 eng
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project