Syringe Selection and Technical Information
General Purpose Manual Syringes:
0.5 - 5 µL NanoVolume
5 µL and 10 µL Metal Plunger
25 - 500 µL Metal Plunger
10 - 500 µL PTFE Tipped Plunger
1 - 100 mL PTFE Tipped Plunger
Syringe Valves:
Syringes Pre-fitted with Syringe Valves
Valve Needles
SealTight™ Valves
GC Autosampler Syringes:
Agilent Instruments
CTC Analytics
CTC PAL-XT and XCHANGE®
Shimadzu Instruments
PerkinElmer Instruments
Thermo Scientific Instruments
Bruker/Varian Instruments
26-34
35
36-37
38
39
40
41
41
42
43
44
45
45
46
46
47
Syringes and Accessories
LC Manual Syringes:
Beckman/Altex, Rheodyne,
SSI Instruments and Valco Valves
LC Autosampler Syringes:
Hitachi Instruments
PerkinElmer Instruments
CTC Analytics
CTC PAL-XT and XCHANGE®
Spark Holland Instruments
Thermo Scientific Instruments
Waters Instruments
LC Pump High Capacity Syringes
Instrument Syringes:
1 - 100 mL PTFE Tipped Plunger
General - Replacement for Hamilton Pump Syringes
Shimadzu Total Organic Carbon Analyzer - TOC5000
Zymark
Special Purpose Syringes:
MEPS™ - Micro Extraction by Packed Sorbent
eVol® MEPS™
GC On-Column
0.5 L to 2 L Jumbo
Gas Sealing Gland
Headspace/Soil Gas
High Pressure
Syringe Accessories:
Repeating Adaptor (RAX)
Syringe Racks
Heated Syringe Cleaner
Needle Cleaning Kit
Stylet Wires
Replacement Guide
Cross Reference guide
Diamond syringe barrels progressing through the production process after having unique, capacity
identifying colors fired on at temperatures approaching 700 °C.
48-49
50
50
51
51
52
52
52
53
54
55
56
56
57
57
58-59
60
61
62
62
63
63
64
64
64
65-69
70-72
Syringes | Syringe Selection and Technical Information
Syringes and
Accessories
SGE offers a complete choice in syringes
with a range of capacities, termination
types, and numerous needle sizes for a
wide range of applications. This selection
guide explains the SGE syringe features
and how to select the ideal syringe for any
application.
Manual, Autosampler or Instrument
Syringe?
If the syringe is being used by hand, a
manual syringe should be selected. If the
syringe is installed in an instrument then
select an autosampler syringe to suit that
particular instrument.
SGE has a large range of manual syringes
for use in chromatography and many other
applications.
SGE’s extensive range of autosampler
syringes meet all fit, form and function
criteria of a specific autosampler model.
As minimum requirements, they meet
dimensional specifications, have accuracy of
better than ± 1 %* and are designed for
precise, worry free overnight sampling.
• The typical scale length on a 0.5 µL – 10 µL
syringe is 54.1 mm.
• The typical scale length on a 25 µL – 25 mL
syringe is 60 mm.
Note: Scale length is sometimes referred to
as stroke length.
What is Termination?
Termination refers to the interface between
the syringe barrel and its mating connection
such as the needle. There are several different
termination options to accommodate a
wide range of applications.
Many syringes are supplied and used with
needles attached; there are also other
terminations available: Luer Lock, Luer Tip,
and threaded terminations.
Luer Lock Termination
• For Luer Lock needles and fittings,
syringe filters and pump priming.
• Specifically designed to secure Luer
Lock needles.
What Size Syringe?
For the best possible injection reproducibility
and accuracy, the smallest injectable volume
from any syringe (with the exception of
eVol®) should be no less than 10 % of its
total capacity, for example: the smallest
recommended injection volume from a 10 µL
syringe would be 1 µL.
SGE’s Termination
Codes:
F Fixed Needle
R Removable
Needle
LL Luer Lock
LT Luer Tip
with submicron tolerances, these syringes
are rugged, robust and reliable with virtually
zero dead volume. Liquid and gas tight, they
provide precision and accuracy of ± 2 %.
To accurately dispense 1 µL or less a NanoVolume syringe is recommended. SGE
NanoVolume syringes are available with
capacities ranging from 500 nL to 5000 nL
(0.5 µL to 5 µL). These syringes can inject
down to 50 nL because the entire sample
is contained within the needle. Designed
Luer Tip Termination
• For Luer Lock needles and fittings.
Luer Lock and Luer Tip
fittings are a universal fitting with a male
Luer taper made from Kel-F® or PTFE to
ISO standard 594. Luer Lock needles and
fittings are used with syringes having Luer
terminations. These syringes are often used
with syringe filters and syringe pumps.
SGE offers both fixed and removable Luer
Lock syringes. Fixed Luer Lock syringes have
a Luer fitting that is permanently fixed to
* Plunger in barrel syringes.
26
For more syringe tips view our video at sge.com/support/videos
the barrel. If the Luer Tip is ever damaged,
the syringe will need to be replaced.
Removable Luer Lock syringes have fittings
that screw onto the barrel with the Luer Tip
inserted. Luer tips and Luer fittings can be
replaced if these are damaged. Removable
Luer tips need to be tightened securely to
ensure they do not come loose during use.
Syringes with threaded terminations screw
into a valve or other device, and are required
for some LC autosamplers, syringe pumps
and dispensers. There are many thread
terminations possible. Contact SGE if you
require a particular threaded termination
that is not covered in this Selection Guide.
Which Needle?
Needle selection is based on application
and personal choice.
Fixed needle.
Removable needle.
Fixed Needle or Removable Needle
Syringes:
Fixed needle syringes are often the preferred
option for experienced operators or for
applications requiring trace sample levels.
A fixed needle syringe is recommended for
autosampler use where the probability of
needle bending is minimal. Fixed needles
are easy to use and the most economical
syringe option.
the needle to be changed for different
applications.
SGE divides its removable needles into
different ranges:
Syringes and
Accessories
•
•
•
•
•
•
•
•
5 µL eVol®
5 µL
10 µL
25 µL to 500 µL
(suitable for 50 µL eVol® Syringes)
1 mL to 2.5 mL
(suitable for 500 µL eVol® Syringes)
5 mL to 10 mL
Luer Lock
Valve Needles
Needles can be easily changed to meet the
application need. For example: a standard
10 µL removable needle syringe can be
easily converted for LC or on-column use.
To maximize accuracy and reproducibility, it is recommended that the
minimum volume
injected from a
syringe is 10% of
the total syringe
capacity.
Gauge or Outer Diameter (OD):
To reduce the possibility of bending,
choose the largest available needle outer
diameter suitable for the application. For
autosamplers, syringes with 23 gauge or
0.63 mm OD cone tipped needles should
be selected for all applications except oncolumn injection.
Inner Diameter (ID):
The ID of the needle is selected to ensure
minimal dead volume without compromising
the ability of the syringe to draw normal
viscosity samples. Medium to high viscosity
samples should be diluted prior to use or a
larger inside diameter needle selected.
For versatility a removable needle syringe
is recommended. The removable needle
syringe reduces cost over time because only
the needle needs to be replaced if bent or
blocked. Removable needle syringes allow
Syringes | Syringe Selection and Technical Information
27
Syringes | Syringe Selection and Technical Information
Needle Tip Styles:
SGE has a variety of needle tip styles to
suit a range of applications and uses.
Syringes and
Accessories
Bevel: Manual GC
The standard general purpose needle tip style
supplied with many SGE syringes is a 20 °
bevel tip. It is the preferred option for manual
injection where piercing the septum in exactly
the same place is difficult. The bevel tip is
designed for optimum septum penetration
and prevention of septum coring. Bevel tip
needles are also known as point style 2.
LC: HPLC
These needles are used for LC and HPLC
valve injection and have a 90 ° square tip
with rounded and polished edges. This
eliminates damage to the valve's rotor seal
and stator face. LC/HPLC tips are also known
as point style 3. This needle tip style is a
good choice for general liquid dispensing.
Dome:
This style needle is recommended for use
with pre-drilled septa. The tip is rounded
and polished to help septum penetration.
Cone: GC Autosampler
The cone shaped needle tip is specially
developed to withstand multi injection
demands and improve septum lifetime
when used with an autosampler. The cone
design effectively “parts” the septum during
piercing instead of cutting it, as would
a bevel needle. Cone tip needles are also
known as point style AS for autosampler.
Side Hole:
Samples are filled and dispensed through
the side hole eliminating septum plugging
of the needle. Ideal for large volume gas
injection. The solid domed tip minimizes
septum damage. Side hole/dome tips are
also known as point style 5.
Dual Gauge:
Sheathed/Bevel: Manual GC
Dual gauge needles have a narrow gauge
at the tip suitable for megabore on-column
injection. The wider gauge for the remainder
of the needle gives increased strength to
the needle for autosampler use.
This needle tip style is the same as the bevel
tip, except a 0.7 mm OD reinforcing sheath
is silver soldered over the standard needle to
within 10 mm of the tip. The sheath provides
exceptional strength to the needle. Sheathed/
Bevel needles are also known as point style 4.
Custom Needles and Syringes
If you are not able to find a needle or syringe to meet
your needs please contact your local SGE distributor
or office for assistance.
28
This selection guide can be viewed as an electronic book at sge.com/selectionguide
Metal or PTFE Tipped Plunger?
A syringe with a PTFE tipped plunger
should be selected when analyzing “dirty”
samples such as serum and urine. The
PTFE tip minimizes carryover and prevents
particulate matter from getting between
the plunger and barrel by effectively wiping
the barrel inner diameter during the plunger
stroke. PTFE tipped plungers are suitable
for both liquid and gas samples. Syringes
with PTFE tipped plungers have the added
benefit of the plungers being replaceable
as the PTFE wears due to use.
NanoVolume (plunger-in-needle)
• Plunger extends into the needle tip.
• Sample is contained only in the needle,
i.e. no glass contact.
• Ideal for dispensing very small liquid
volumes.
• Recommended for use when sample
volume is less than 1000 nL (1 µL).
• Capacities: 500 nL (0.5 µL), 1000 nL (1
µL) and 5000 nL (5 µL).
Metal plungers are individually fitted to the
™
syringe glass barrel for a perfect “feel”, SuperfleX Flexible Plunger
providing optimized life with minimal carry • Made from Titanium/
Nickel alloy.
over, a liquid tight seal between the barrel
•
Virtually
indestructible
and plunger and excellent performance.
plunger.
• Ideal for student use.
SGE Plunger Options:
• Capacities: 5 µL and 10 µL.
Metal Plunger
• Stainless steel plunger individually fitted
to its own syringe barrel.
• Plunger is not replaceable.
• Industry standard syringe for chromatography applications.
• For use when injection volume is greater
than 1 µL.
• Capacities: 5 µL to 500 µL
Syringes and
Accessories
Special Purpose
Syringes
SGE makes a range
of special purpose
syringes:
• On-column syringes
for direct injection
into a GC column.
• High-pressure syringes for applications where the
syringe is exposed
to elevated pressures.
• Jumbo syringes –
500 mL, 1 L and
2 L often used for
air sampling.
Refer to Special Purpose Syringe section
on pages 57-62.
Plunger Protection
• Extended protection at the top of the
syringe back flange to help prevent
plunger bending during injection and
improve plunger stroke.
• Ideal for general use for both experienced
and inexperienced users.
• Capacities: 5 µL and 10 µL (not necessary
for capacities larger than 10 µL due to
strength of the wider plunger diameter).
PTFE Tipped Plunger
•
•
•
•
•
Suitable for both liquid and gas samples.
Plunger is replaceable.
Ideal for “dirty” samples.
Suitable for gas or headspace applications.
Easy to remove and clean to extend plunger
life.
• Capacities: 10 µL to 100 mL.
Guided Plunger
• Extended barrel guides plunger during
injection.
• Robust and rugged.
• Ideal for student use.
• Capacities: 5 µL and 10 µL.
Syringes | Syringe Selection and Technical Information
29
Syringes | Syringe Selection and Technical Information
Syringe Care, Maintenance and Use
An SGE syringe is a precision instrument
with a high standard of fit between the
plunger and the glass barrel. Like most
precision instruments, regular maintenance is
important for ensuring long life and robust
performance.
Syringes and
es
Accessories
+
Syringes should be routinely checked for
damage to the barrel and needle. Look for
fine cracks in the barrel. Needles should also
be checked for burrs and rough surfaces
which may cause tearing and excessive wear
on the septum.
Syringe Cleaning
Syringe cleaning agents will usually depend
on the contaminating material. Methanol,
methylene chloride, acetonitrile and acetone
are commonly used.
SGE Syringe
Temperature Specifications
Heating will remove semi-volatile material
from the syringe. Before heating or autoclaving
remove the plunger.
• Fixed Needle and Fixed Luer Syringes can
be heated in an oven to 70 °C.
• Removable Needle and Removable Luer
Syringes can be heated in an oven to
120 °C.
• NanoVolume Syringes can be heated in
an oven to 70 °C.
Rapid changes in temperature can lead to
splitting of the glass barrel. Ensure heating
and cooling of a syringe is a gradual
process.
Plunger Care
Do not immerse the entire syringe in solvent
as this may damage the adhesive used to
bond parts of the syringe. Clean externally
by wiping with a tissue.
Syringe Cleaning Steps:
1. Rinse thoroughly with suitable solvent.
2. Rinse with distilled water.
3. Flush with acetone.
4. Remove plunger and wipe with tissue.
5. Refit plunger and flush with acetone.
6. Allow syringe to dry.
For best syringe life,
ensure your syringe
is rinsed 5 to 10
times with clean
solvent after
use.
30
Cleaning Steps for NanoVolume syringes can
be found in the manual supplied with the
syringe.
Metal Plungers for Standard Syringes
• Never force the plunger.
• Do not pump the plunger when the
needle is blocked as the high pressure
generated could crack the barrel.
• Replacement metal plungers are not
available. Plungers are individually
fitted to the barrels to achieve a perfect
seal. This means that plungers are not
interchangeable.
• Avoid unnecessary movement of plungers
when the syringe is dry.
Metal Plungers for NanoVolume
Syringes
• Always loosen needle cover nut before
removing or inserting plunger.
For more syringe tips view our video at sge.com/support/videos
• Wipe plunger with a lint-free tissue
before replacing into the syringe.
• A heated syringe cleaner is recommended
for cleaning needles and plungers of
NanoVolume syringes.
Syringes and
Accessories
PTFE Tipped Plungers
• Avoid unnecessary movement of plungers
when syringes are dry.
• Replacement PTFE tipped plungers are
available.
Heated Syringe Cleaner (Part No. 031780,
031781): A heated syringe cleaner will
remove organic residues from needles and is
particularly useful for syringe cleaning when
performing trace analysis (see page 64).
Needle Care
Syringe Use
Unblocking needles:
1. To unblock the needle, remove the
plunger and fill the syringe with solvent
using another syringe.
2. Insert plunger and gently push solvent
through the needle. Never force the
plunger as too much pressure may crack
the syringe barrel.
SGE Syringe Cleaning Accessories:
Needle Cleaning Kit (Part No. 031782):
The kit contains a range of stylet wires for
needle cleaning, tweezers and a surfactant
material for barrel cleaning (see page 64).
• Always inspect the syringe before use.
Check the barrel for cracks and the
needle tip for burrs.
• To eliminate carryover between samples,
flush the syringe with solvent 5-20 times,
remembering to discard at least the first
2-3 washes.
• To eliminate air bubbles from the barrel,
repeatedly draw and expel sample while
keeping the needle tip immersed in the
solution. Bubbles can also be removed by
turning the barrel upright while expelling
some of the sample. If bubbles persist,
slow the aspiration speed.
• To make an injection, overfill the syringe
then press the plunger until the correct
volume is reached. Draw the plunger
back slightly then wipe the needle tip
with a lint free tissue. Make injection.
For improved precision, syringes can be
fitted with a repeating adaptor, which
allows the volume to be preset on the
syringe.
• Before storage always rinse the syringe
with clean solvent and air dry.
Syringes | Syringe Selection and Technical Information
31
Syringes | Syringe Selection and Technical Information
Syringe Structure
Syringes and
Accessories
Needle Tip
A range of tip
styles are available.
This makes SGE
syringes suitable
for a wide range
of
applications.
See page 28.
Needle
Stainless steel needles for
robustness and corrosion
resistance.
Fixed
and
removable needle options
in a wide range of lengths
and diameters.
Removable Needle
Needles can be replaced
if bent, blocked or broken
without the need to replace
the entire syringe.
Needle Seal
/ Spring/Hub
For replacement
seals see page
68.
Knurled Front
Cover Nut
For replacement
cover nuts see
page 68.
Front Screw or Needle Cap
Made from Nickel plated
brass, protects the syringe
barrel from chipping and
breakage.
Plunger Tip
PTFE or metal.
Syringe Barrel Internal Diameter (ID)
When using a syringe pump the internal diameter of the syringe barrel is required to
calculate the pumping speed. The table below lists the internal diameters of SGE syringes
based on volume.
Syringe Volume
5 µL
10 µL
25 µL
50 µL
100 µL
250 µL
500 µL
1 ML
Internal Diameter of Syringe Barrel (mm)
0.343
0.485
0.728
1.030
1.457
2.303
3.257
4.606
2.5 ML
5 ML
10 ML
25 ML
50 ML
100 ML
7.284
10.30
14.57
23.03
27.50
34.99
Syringe Volume
Internal Diameter of Syringe Barrel (mm)
Please note due to variations in scale length some autosampler syringes have different internal diameters than those listed here.
32
Information on our products in French and German can be found at www.sge.com
then select your language.
Syringes and
Accessories
Backing Strip and Scale
Backing strip minimizes
reading off scale.
error
when
Scale is sharp, clear and easy to read –
maximizes accuracy and precision.
Barrel
Made from borosilicate
glass for robustness and
solvent resistance.
Back Flange
Shape provides stability
and
prevents
syringe
rolling away, made from
nickel plated brass to resist
fracture.
Plunger Protection
Guides the plunger
into the syringe.
Helps to prevent
plunger bending.
Plunger
Stem
Plunger Button
Designed for easy
syringe use or
to fit appropriate
autosampler.
Bright white backing with black scale
markings on manual syringes for accurate
reading of the syringe scale.
Color by volume on autosampler syringes
for easy identification of installed
syringes.
Syringe Troubleshooting
Problem
Cause
Solution
Blocked Needles
Improper cleaning.
Refer to syringe cleaning tips (page 30).
Inappropriate needle selection.
Refer to needle selection guide (page 27).
Seized Plungers
Poor dispensing technique.
Ensure correct injection technique being followed.
A build up of dirty samples.
Ensure correct syringe cleaning procedures are being
followed (page 30).
Poor Reproducibility
Air Bubbles
Syringe installed in autosampler incorrectly.
Ensure syringe installed correctly.
Incorrect syringe selection.
Refer to selection guide (page 26), the dispensed
volume should be greater than 10 % of the entire syringe
capacity.
Poor operator technique.
Check that each sample is being injected in the same
way.
Incorrect instrument setup.
Check if any changes have been, or need to be made, to
your instrument or setup (septa, injection port liner, etc).
Needle tip not fully immersed in sample or air being Repeatedly draw and expel sample while keeping needle
pulled up from sample by operator technique.
tip immersed.
Turning the syringe upright while expelling the sample
may help in the removal of the bubble.
Slow down.
Leakages
Leakage around needle due to needle fitted Remove and refit the needle. Check seal is in place and
incorrectly.
undamaged.
No seal at plunger tip – plunger tip damaged or Replace plunger assembly if using a PTFE tipped plunger.
worn due to use or using syringe dry.
Ghost Peaks
Dirty needle.
Between samples flush the syringe with solvent 5-20
times (discard at least the first 2-3 washes).
Consider a heated syringe cleaner.
Unable to Draw Up Often thought to be due to a leaking plunger, Refer to syringe cleaning tips. Remove and refit the
Liquid
however, most often caused by blocked needle or needle. Check seal is in place and undamaged.
leaking needle seal.
No seal at plunger tip - plunger tip damaged or Replace plunger assembly if using a PTFE tipped plunger.
worn due to use or using syringe dry.
Syringes | Syringe Selection and Technical Information
33
Syringes | Syringe Selection and Technical Information
Syringe Validation and Calibration
Syringes and
Accessories
If your laboratory is involved in GLP, ISO,
GMP, NAMAS, ANSI, BSI or National
Standards Protocol, then you will appreciate
the importance of instrument calibration
and its traceability. Although essential, this
is often a time consuming, error prone and
costly exercise to perform.
Certificate of Conformance
SGE supplies a syringe conformance
certificate with every syringe to guarantee
the syringe meets all specifications.
This syringe conformance certificate satisfies
protocol requirements for syringes and
provides traceability back to International
Standards.
SGE syringes are produced in a manufacturing
environment that operates under a quality
management system that is independently
certified in accordance with ISO9001:2008. All
measuring equipment involved in production
processes is calibrated and traceable to
international standards and records are
maintained. Through adherence to our
quality system requirements SGE ensures
that displacement volume will meet our
specification for accuracy and reproducibility.
To order a calibrated syringe simply add ‘CAL’
to the end of the part number when ordering.
For example; if you require a calibration
certificate for part number 002000, 10 µL
fixed needle syringe; order part number
002000CAL.
SGE’s eVol® – Digitally controlled analytical
syringe, is the world’s first user calibrated
analytical syringe. Every eVol® is factory
tested to ensure its operation complies with
a comprehensive list of criteria. To achieve the
highest level of accuracy possible each syringe
may be calibrated. This will ensure your eVol®
will dispense more accurately than any other
manual syringe-based dispensing technique.
A calibration factor for each syringe is used to
adjust the software instructions controlling the
motor to compensate for any slight variations
in the positively displaced liquid volume. The
calibration procedure for eVol® is based on a
gravimetric measure of the volume dispensed
from the eVol® (refer to page 22 for more
details).
Certificate of Calibration
• Available for all SGE Syringes
SGE offers a factory calibration service, at an
additional cost, for any syringe nominated
by you at the time of purchase. These
syringes are supplied with a Certificate of
Calibration providing volume conformance
and traceability. For identification each
calibrated syringe is uniquely numbered
and marked with this number.
34
Syringes | Syringe Selection and Technical Information
Syringes | General Purpose Manual Syringes
0.5 - 5 µL NanoVolume
With the ability to inject down to 50 nL
with high precision and accuracy, SGE
NanoVolume Syringes are perfect for
NanoVolume capillary chromatography
injection as well as making accurate
standards that require small volumes.
Displacing the full sample during injection
results in virtually zero dead volume and
carry over between
Reduced Tip Diameter
injections.
The plungers and
needles are matched
sets and must be
replaced as a set.
Refer to page 65 for
a list of replacement
plunger and needle
kits.
The sample is only drawn into the needle,
not the syringe barrel. When the plunger
is depressed, the sample is completely
dispensed by the NanoVolume plunger that
extends to the tip of the needle.
Syri
Syringes
and
Ac
Accessories
Sample
Needle
Plunger
NOZZLE TIP SHOWN IN
DIAGRAM.
SPECIFICATIONS
Accuracy and Reproducibility
± 2 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
6.5 mm and 8 mm
Scale Length
0.5 µL (6.5 mm OD barrel) = 27.05 mm, 0.5 µL (8 mm OD barrel) =
63.7 mm, 1 µL = 54.1 mm, 63.7 mm, 5 µL = 48.7 mm
International Standards Traceability
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Needle and Plunger
Part No.
Syringe
Part No.
000300
6.5 mm Outer Diameter (OD) Barrel
0.5 µL
50
23
0.63
0.155
Cone
0.5BNR-5
033010
0.5 µL
50
23
0.63
0.155
Bevel
0.5BNR-5BV
033011
000301
0.5 µL
50
26
0.47
0.155
Cone
0.5BNR-5/0.47
033012
000303
000310
8.0 mm Outer Diameter (OD) Barrel
0.5 µL
70
23
0.63
0.1
Cone
0.5BR-7
033057
0.5 µL
70
23
0.63
0.1
Bevel
0.5BR-7BV
033060
000311
1 µL
50
23
0.63
0.155
Cone
1BR-5
034055
000500
1 µL
50
23
0.63
0.155
Bevel
1BR-5BV
034056
000501
1 µL
70
23
0.63
0.155
Cone
1BR-7
034057
000505
1 µL
70
23
0.63
0.155
Bevel
1BR-7BV
034060
000506
1 µL
115
23
0.63
0.155
Cone
1BR-11.5
034059
000510
1 µL
70
26
0.47
0.155
Cone
1BR-7/0.47
034610
000570
5 µL
50
23
0.63
0.365
Cone
5BR-5
035055
000800
5 µL
50
23
0.63
0.365
Bevel
5BR-5BV
035056
000801
5 µL
70
23
0.63
0.365
Cone
5BR-7
035057
000802
5 µL
70
23
0.63
0.365
Bevel
5BR-7BV
035058
000803
5 µL
115
23
0.63
0.365
Cone
5BR-11.5
035059
000804
5 µL
70
23
0.63
0.365
Nozzle
5BR-7N
035060
000805
When
replacing
the plunger and
needle follow the
instructions included in the kit – the
front cover nut
must be loosened
before removing
the plunger.
Syringes Fitted with Repeating Adaptor
See page 63 for more details about the RAX repeating adaptor.
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Needle and Plunger
Part No.
Syringe
Part No.
6.5 mm Outer Diameter (OD) Barrel
0.5 µL
50
23
0.63
0.155
Cone
0.5BNR-5-RAX
033010
000350
0.5 µL
50
26
0.47
0.155
Cone
0.5BNR-5/0.47-RAX
033012
000353
8.0 mm Outer Diameter (OD) Barrel
0.5 µL
70
23
0.63
0.1
Cone
0.5BR-7-RAX
033057
000355
1 µL
50
23
0.63
0.155
Cone
1BR-5-RAX
034055
000550
1 µL
70
23
0.63
0.155
Cone
1BR-7-RAX
034057
000553
Syringes | General Purpose Manual Syringes
35
Syringes | General Purpose Manual Syringes
5 - 10 µL Metal Plunger
SPECIFICATIONS
Syringes and
es
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
6.5 mm (guided plunger syringes 8 mm)
Scale Length
54.1 mm
International Standards Traceability
Standard Plunger Protection Syringes
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe
Code
Replacement 6 Pack
Needle
Syringe
Part No.
Part
No.
10 Pack
Syringe
Part
No.
25 Pack
Syringe
Part
No.
Syringe
Part No.
Fixed Needle
5 µL
50
26
0.47
0.11
Bevel
5F
-
-
-
-
001000
5 µL
70
26
0.47
0.11
Bevel
5F-7
-
-
-
-
001002
5 µL
42
23
0.63
0.11
Cone
5F4.2/0.63C
-
-
-
-
008139
10 µL
50
26
0.47
0.11
Bevel
10F
-
002030
002033
002035
002000
10 µL
70
26
0.47
0.11
Bevel
10F-7
-
-
-
-
002003
10 µL
50
26
0.47
0.11
cone
10F-5C
-
-
-
-
002005
10 µL
115
26
0.47
0.11
Bevel
10F-11.5
-
-
-
-
002007
10 µL
42
23
0.63
0.11
Cone
10F4.2/0.63C
-
-
-
-
002839
Removable Needle
5 µL
50
26
0.47
0.11
Bevel
5R
036110
-
-
-
001050
10 µL
50
26
0.47
0.11
Bevel
10R
037110
002080
-
-
002050
10 µL
70
26
0.47
0.11
Bevel
10R-7
037130
-
-
-
002055
SuperFlex™ Syringes
Plunger protection helps prevent
plunger bending
during injection.
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Needle
Part No.
6 Pack
Syringe
Part No
Syringe
Part No.
001100
Fixed Needle
5 µL
50
26
0.47
0.11
Bevel
5FX
-
-
5 µL
50
26
0.47
0.11
Cone
5FX-5C
-
-
001105
10 µL
50
26
0.47
0.11
Bevel
10FX
-
002130
002100
10 µL
70
26
0.47
0.11
Bevel
10FX-7
-
-
002101
10 µL
50
26
0.47
0.11
Cone
10FX-5C
-
002133
002105
10 µL
50
23
0.63
0.11
Cone
10FX-5/0.63C
-
002135
002108
Removable Needle
5 µL
50
26
0.47
0.11
Bevel
5RX
036110
-
001150
10 µL
50
26
0.47
0.11
Bevel
10RX
037110
002180
002150
The virtually indestructible
Titanium Nickel alloy plunger
of the SuperFlex™ Syringes is
ideal for student use.
36
This selection guide can be viewed as an electronic book at sge.com/selectionguide
Syringes and
Accessories
Guided plunger syringes are the most rugged
syringe available, making them perfect for
industrial environments.
Guided Plunger Syringes
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Needle
Part No.
6 Pack
Syringe
Part No
Syringe
Part No.
Fixed Needle
5 µL
50
26
0.47
0.11
Bevel
5F-GP
-
-
001400
10 µL
50
26
0.47
0.11
Bevel
10F-GP
-
-
002400
001450
Removable Needle
5 µL
50
26
0.47
0.11
Bevel
5R-GP
036110
-
5 µL
70
26
0.47
0.11
Bevel
5R-GP-7
036130
-
001455
5 µL
50
26
0.47
0.11
Bevel
5R-GPS
037110
-
001495*
10 µL
50
26
0.47
0.11
Bevel
10R-GP
037110
-
002450
10 µL
70
26
0.47
0.11
Bevel
10R-GP-7
037130
-
002453
* Short half scale syringe (scale length 27 mm).
Syringes Fitted with Repeating
ti Adaptor
Ad t
See page 63 for more details about the RAX repeating adaptor.
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
26
0.47
0.11
Bevel
Syringe Code
Replacement 6 Pack
Needle
Syringe
Part No.
Part No
Syringe
Part No.
Fixed Needle
10 µL
50
10F-RAX
-
-
002040
Removable Needle
5 µL
50
26
0.47
0.11
Bevel
5R-RAX
036110
-
001090
10 µL
50
26
0.47
0.11
Bevel
10R-RAX
037110
-
002090
036110
-
001490
Removable Needle - Guided Plunger
5 µL
50
26
0.47
0.11
Bevel
5R-GP-RAX
10 µL
50
26
0.47
0.11
Bevel
10R-GP-RAX
037110
-
002490
10 µL
70
26
0.47
0.11
Bevel
10R-GP-7-RAX
037130
-
002493
Syringes | General Purpose Manual Syringes
The RAX repeating
adaptor improves
precision and reproducibility when
repeatedly injecting
the same volume
manually.
37
Syringes | General Purpose Manual Syringes
25 - 500 µL Metal Plunger
SPECIFICATIONS
Syringess and
ries
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
8 mm
Scale Length
60 mm
International Standards Traceability
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Needle
Part No.
Syringe
Part No.
Fixed Needle
25 µL
50
25
0.5
0.2
Bevel
25F
-
003000
50 µL
50
25
0.5
0.2
Bevel
50F
-
004000
100 µL
50
25
0.5
0.2
Bevel
100F
-
005000
250 µL
50
25
0.5
0.2
Bevel
250F
-
006000
500 µL
50
25
0.5
0.2
Bevel
500F
-
007000
Removable Needle
25 µL
50
25
0.5
0.2
Bevel
25R
038110
003050
50 µL
50
25
0.5
0.2
Bevel
50R
038110
004050
100 µL
50
25
0.5
0.2
Bevel
100R
038110
005050
100 µL
70
25
0.5
0.2
Bevel
100R-7
038130
005055
250 µL
50
25
0.5
0.2
Bevel
250R
038110
006050
500 µL
50
25
0.5
0.2
Bevel
500R
038110
007050
Replacement
Needle
Part No.
Syringe
Part No.
Syringes Fitted with Repeating Adaptor
See page 63 for more details about the RAX repeating adaptor.
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Removable Needle
25 µL
50
25
0.5
0.2
Bevel
25R-RAX
038110
003090
50 µL
50
25
0.5
0.2
Bevel
50R-RAX
038110
004090
100 µL
50
25
0.5
0.2
Bevel
100R-RAX
038110
005090
250 µL
50
25
0.5
0.2
Bevel
250R-RAX
038110
006090
500 µL
50
25
0.5
0.2
Bevel
500R-RAX
038110
007090
To eliminate carryover between samples, flush the
syringe with solvent 5-20 times, remembering to
discard the first 2-3 washes.
38
For more syringe tips view our video at sge.com/support/videos
10 - 500 µL PTFE Tipped Plunger
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
10 µL = 6.5 mm, 25 – 500 µL = 8 mm
Scale Length
10 µL = 54.1 mm, 25 –500 µL = 60 mm
Syringes and
Accessories
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
6 Pack
Syringe
Part
No.
Syringe
Part
No.
Fixed Needle
10 µL

50
26
0.47
0.11
Bevel
10F-GT
-
031810
002202
002200
10 µL

70
26
0.47
0.11
Bevel
10F-GT-7
-
031810
-
002208
25 µL

50
25
0.50
0.20
Bevel
25F-GT
-
031815
-
003200
004200
50 µL

50
25
0.50
0.20
Bevel
50F-GT
-
031820
-
100 µL

50
25
0.50
0.20
Bevel
100F-GT
-
031825
-
005200
250 µL

50
25
0.50
0.20
Bevel
250F-GT
-
031830
-
006200
500 µL

50
25
0.50
0.20
Bevel
500F-GT
-
031835
-
007200
002250
Removable Needle
10 µL

50
26
0.47
0.11
Bevel
10R-GT
037110
031811
002252
25 µL

50
25
0.50
0.20
Bevel
25R-GT
038110
031815
-
003250
50 µL

50
25
0.50
0.20
Bevel
50R-GT
038110
031820
-
004250
100 µL

50
25
0.50
0.20
Bevel
100R-GT
038110
031825
-
005250
250 µL

50
25
0.50
0.20
Bevel
250R-GT
038110
031830
-
006250
500 µL

50
25
0.50
0.20
Bevel
500R-GT
038110
031835
-
007250

50
26
0.47
0.11
Bevel
10R-GP-GT
037110
031805
-
002455

75
-
0.17
0.11
On10R-GT-OCColumn CE
037675
031811
-
002500
Guided Plunger
10 µL
On-Column
10 µL
Fixed Luer Tip
50 µL

-
-
-
-
-
50F-LT-GT
-
031820
-
004229
100 µL

-
-
-
-
-
100F-LT-GT
-
031825
-
005229
250 µL

-
-
-
-
-
250F-LT-GT
-
031830
-
006229
500 µL

-
-
-
-
-
500F-LT-GT
-
031835
-
007229
Fixed Luer Lock
50 µL

-
-
-
-
-
50F-LL-GT
-
031820
-
004230
100 µL

-
-
-
-
-
100F-LL-GT
-
031825
-
005230
250 µL

-
-
-
-
-
250F-LL-GT
-
031830
-
006230
500 µL

-
-
-
-
-
500F-LL-GT
-
031835
-
007230
Syringes | General Purpose Manual Syringes
39
Syringes | General Purpose Manual Syringes
1 - 100 mL PTFE Tipped Plunger
Also Suitable for Syringe Pumps and Dispensers
Syringes and
es
Accessories
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
1 mL = 9 mm, 2.5 mL = 11 mm, 5 mL = 14 mm, 10 mL = 18 mm,
25 mL = 27 mm, 50 mL = 32.8 mm, 100 mL = 40.8 mm
Scale Length
1 – 25 mL = 60 mm, 50 mL = 84.2 mm, 100 mL = 104 mm
Thread in Plunger Button
6-32 UNC
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
1 mL
50
22
0.72
0.37
Bevel
2.5 mL
50
22
0.72
0.37
Bevel
Syringe Code
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
1MDF-GT
-
0318441
008102
2.5MDF-GT
-
031852
008502
Fixed Needle
Removable Needle
1 mL
50
23
0.63
0.32
Bevel
1MR-GT
039110
031842
008100*
2.5 mL
50
23
0.63
0.32
Bevel
2.5MDR-GT
039110
031852
008500
5 mL
50
23
0.63
0.32
Bevel
5MDR-GT
031516
031856
008700
10 mL
50
23
0.63
0.32
Bevel
10MDR-GT
031516
031862
008900
1.0 mL
-
-
-
-
Luer Tip
1MF-LT-GT
-
031842
008020*
2.5 mL
-
-
-
-
Luer Tip
2.5MDF-LT-GT
-
031852
008420
Fixed Luer Tip
Fixed Luer Lock
1.0 mL
-
-
-
-
Luer Lock
1MDF-LL-GT
-
0318441
008025
2.5 mL
-
-
-
-
Luer Lock
2.5MDF-LL-GT
-
031852
008425
5 mL
-
-
-
-
Luer Lock
5MDF-LL-GT
-
0318562
008762
10 mL
-
-
-
-
Luer Lock
10MDF-LL-GT
-
031864
008962
25 mL
-
-
-
-
Luer Lock
25MDF-LL-GT
-
031874
009463
Removable Luer Lock
5 mL
-
-
-
-
Luer Lock
5MDR-LL-GT
-
031856
008760
10 mL
-
-
-
-
Luer Lock
10MDR-LL-GT
-
031862
008960
25 mL
-
-
-
-
Luer Lock
25MR-LL-GT
-
031870
009462
50 mL
-
-
-
-
Luer Lock
50MR-LL-GT
-
0312170
009660*
100 mL
-
-
-
-
Luer Lock
100MR-LL-GT
-
0312176
009760*
* No thread in plunger stem of syringe part numbers 008100, 008020, 009660 and 009760.
Syringes | Syringe Valves
Syringe valves are ideal for sample storage
and transportation or to pressurize sample
prior to injection.
SGE Luer Tip, Luer Lock and removable
needle syringes can be fitted with valves.
The valve allows fluid to be stored in the
syringe without contamination.
SGE offers three basic types of manually
operated syringe valves; push-pull for smaller
volumes (25 µL – 2.5 mL), septum and pushbutton for larger volumes (5 mL – 2 L).
40
For more syringe tips view our video at sge.com/support/videos
Push-pull Valves
Septum Valve
CLOSE
Push-button Valves
OPEN
OPEN
(Turn to
close)
CLOSE
OPEN
Syringes and
Accessories
Part No. 031911
The septum cap (P/N 031911)
allows sample access without
loss or contamination. It can
be removed and Luer Lock
needles or devices fitted.
Part No. 031905
031
Part No. 031907
031
and 031906
Push-pull valves suit removable needle
25 µL - 2.5 mL syringes.
Description
Syringe Volume
Part No. 031910
Suits 5 mL - 2 L
syringes
with
removable Luer
Lock or removable needle.
Valve Code
Part No. 031915
Suitable for any
Luer Lock and Luer
Tip syringes or other Luer devices.
Replacement
Needle
Part No.
Valve
Part No.
Push-pull Valve with Replaceable 23 Gauge Needle
25 µL - 2.5 mL
V25/2.5M-0.63C
038810
031905*
Push-pull Valve with Replaceable 26 Gauge Needle
25 µL - 2.5 mL
V25/2.5M-0.47C
038820
031906ˆ
Push-pull Valve with Luer Lock
25 µL - 2.5 mL
VLL25/2.5M
-
031907
031910
Push-button Valve with Luer Lock or Removable Needle
5 mL - 2 L
VLLMA
-
Septum Valve
5 mL - 2 L
VLLMA5/2000
-
031911
Push-button Valve for Luer Lock Devices
50 µL - 2 L
SLLV
-
031915
With the valve in
the closed position
it is possible to
move the plunger
to pre-pressurize
the sample.
* 50 mm, 0.63 mm OD cone tip needle. ˆ 50 mm, 0.47 mm OD cone tip needle.
Syringes Pre-fitted with Syringe Valves
Syringe
Volume
PTFE
Tipped
Plunger
Syringe Code
Replacement Replacement Replacement
Needle
Plunger
Valve
Part No.
Part No.
Part No.
Syringe
Part No.
Pre-fitted with Removable Needle Push-pull Valve
50 µL
50R-V-GT
038810
031820
031905
100 µL
100R-V-GT
038810
031825
031905
005279
250 µL
250R-V-GT
038810
031830
031905
006279
500 µL
500R-V-GT
038810
031835
031905
007279
1 mL
1MR-V-GT
038810
031842
031905
008110
2.5MDR-V-GT
038810
031852
031905
008510
1MR-VLL-GT
-
031842
031907
008160
2.5MDR-VLL-GT
-
031852
031907
008560
008770
2.5 mL
004279
Pre-fitted with Luer Lock Valve
1 mL
2.5 mL
5 mL
5MDR-VLLMA-GT
-
031856
031910
10 mL
10MDR-VLLMA-GT
-
031862
031910
008970
25 mL
25MDR-VLLMA-GT
-
031870
031910
009472
50 mL
50MR-VLLMA-GT
-
0312170
031910
009670
100 mL
100MR-VLLMA-GT
-
0312176
031910
009770
Pack Size
Valve Needle
Part No.
038810
Valve Needles
Needle Length
(mm)
Needle Gauge
Needle OD
(mm)
Needle ID
(mm)
Needle Tip
For use with P/N 031905 and 031906
50
23
0.63
0.20
Cone
1
50
23
0.63
0.20
Side Hole/Dome
1
038815
50
26
0.47
0.24
Cone
1
038820
See page 67 for the complete range of Luer Lock needles suitable for use on Luer Lock valves.
Syringes | Syringe Valves
41
Syringes | Syringe valves
SealTight™
Syringes and
Accessories
SealTight™ low pressure valves are designed for improved valve seal life. SGE valves have
overcome the problem of leakage by reducing perpendicular rotor force, and optimizing the
rotor face union, thereby improving PTFE plug integrity. The end result is a longer life seal.
The SealTight™ Valves are completely inert and enable connection of a variety of fittings.
Valves are available in standard (SV) or bulkhead panel mounting connection (SVP) which
can be easily mounted to a dispenser. Other valves, including custom OEM configurations,
are available.
SPECIFICATIONS
ADVANTAGES
Flow Path
1.5 mm (0.059")
Threaded Ports
1/4–28 UNF
Pressure Rating
120 psi
Temperature Rating
10 – 120 °C
Standard Weight
58 g
Bulkhead Weight
65 g
Breakaway Torque
0.15 Nm
Lifetime Testing
≥ 8,000 cycles
Description
Mounting
Code
Part No.
Bulkhead
SVP-2L/D
030025
Distribution Valves
• Extended life resulting from face
rotor seal technology,
making valves cost
effective and reliable.
• Inert PTFE and Kel-F®
flow path compatible with a variety of
solvents and sample
matrices.
• Easily reassembled
by hand: no need to
torque it up like other
valves.
• Screw thread for connection onto 5 mL –
2 L syringes using syringe-valve connector
(Part No. 030930).
2-way L
3-way T
Standard
SV-3T/D
030040
3-way T
Bulkhead
SVP-3T/D
030045
2-way L
3-way T
Port Valves
I flow 2 port
Standard
SV-2I/I
030200
T flow 3 port
Standard
SV-3T/T
030240
T flow 3 port
Bulkhead
SVP-3T/T
030245
L flow 3 port
Standard
SV-3T/L
030260
L flow 3 port
Bulkhead
SVP-3T/L
030265
I flow 2 port
T flow 3 port
L flow 3 port
™
APPLICATIONS
SealTight™ valves offer
the versatility to be
utilized in a variety
of
industries
and
applications:
• Dispensers.
• Diluters.
• Flow path variation.
• Biocompatible, suitable for use in pathology equipment.
42
SealTight Valve Fittings and Connectors
Description
Code
Part No.
KSV-FL
030900
Kel-F Male Luer
KSV-LT
030905
Metal Thread Male Luer Lock - PTFE Flow Path
MSV-LL
030920
MSV-SYR
030930
Flangeless Tubing Connector for 1/16" Tubing (includes 2 ferrules)
MSV-1/16
030950
Flangeless Tubing Connector for 1/8" Tubing (includes 2 ferrules)
MSV-1/8FLT
030952
Replacement Ferrules for 1/16" Tubing
PF16-16
0730018
Replacement Ferrules for 1/8" Tubing
PF8-8
0730019
Kel-F® Female Luer
®
Syringe-Valve Connector (fits 5 mL – 2 L syringes) PTFE Flow Path
Syringes | Syringe Valves
Syringes | GC Autosampler Syringes
Agilent Instruments
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume) (± 2 % for 0.5 µL and 1 µL syringes)
Borosilicate Glass Barrel Outer Diameter (OD)
0.5 µL = 6.5 mm, 1 µL = 8 mm (except P/N 000610 which is 6.5 mm) 5 µL to 250 µL = 6.5 mm
Scale Length
0.5 µL = 27.05 mm, 1 µL to 250 µL = 54.1 mm (except P/N 000610 which is 27.05 mm)
-
001804
-
-
001814
-
5 µL
-
42
23-26
Cone 5F-AG-0.63/0.47
-
-
001822
-
10 µL
-
42
26
0.47
0.11
Cone 10F-AG-0.47
-
-
002804
10 µL
-
42
23
0.63
0.11
Cone 10F-AG-0.63
-
-
002814
10 µL

42
23
0.63
0.11
Cone 10F-AG-GT-0.63
-
031808
10 µL
-
42
23-26
0.63/0.47 0.11
Cone 10F-AG-0.63/0.47
-
-
Needle Tip
Syringe Part No.
-
Cone 5F-AG-0.63
25 Pack Syringe
Part No.
6 Pack Syringe
Part No.
Cone 5F-AG-0.47
0.11
10 Pack Syringe
Part No.
Replacement
Plunger Part No.
0.11
Syringe Code
0.47
0.63
Needle ID (mm)
26
23
Needle Gauge
42
42
Needle Length
(mm)
-
PTFE Tipped
Plunger
5 µL
5 µL
Syringe Volume
Replacement
Needle Part No.
Needle OD (mm)
International Standards Traceability
-
-
001800
-
001821
-
-
002800
-
002813
002810
-
-
-
002812
002822
-
Syringes and
Accessories
HP7673, 7683, 7693A and 6850ALS Fixed Needle
0.63/0.47 0.11
001810
002824 002821
10 µL

42
23-26
0.63/0.47 0.11
Cone 10F-AG-GT-0.63/0.47
-
031808 002827
-
-
002826
25 µL

42
23-26
0.63/0.47 0.24 Cone 25F-AG-GT-0.63/0.47
-
031818
-
-
-
003668
50 µL

42
23-26
0.63/0.47 0.24 Cone 50F-AG-GT-0.63/0.47
-
031142
-
-
-
004668
100 µL

42
23-26
0.63/0.47 0.24 Cone 100F-AGGT-0.63/0.47
-
031823
-
-
-
005668
Cone 10FX-AG-0.47
-
-
002831
-
-
002830
0.11
Cone 10FX-AG-0.63
-
-
002838
-
-
002835
PTFE Tipped
Plunger
Needle Length
(mm)
Needle Gauge
42
26
0.47
0.155 Cone 0.5BR-AG-0.47
033708*
-
-
-
-
000400
-
42
23
0.63
0.155 Cone 0.5BR-AG-0.63
033715*
-
-
-
-
000410
0.5 µL
-
42
23-26
033730*
-
-
-
-
000415
1 µL
-
42
23
034715*
-
-
-
-
000610
5 µL
-
42
001805
5 µL
-
42
5 µL
-
42
23-26
10 µL
-
42
10 µL
-
42
10 µL

42
10 µL

10 µL
10 µL
Needle Tip
Syringe Code
-
0.5 µL
Needle ID (mm)
0.5 µL
Needle OD (mm)
Syringe Part No.
0.11
25 Pack Syringe
Part No.
0.47
0.63
10 Pack Syringe
Part No.
26
23
6 Pack Syringe
Part No.
42
42
Replacement
Plunger Part No.
-
Replacement
Needle Part No.
10 µL
10 µL
Syringe Volume
HP7673, 7683, 7693A and 6850ALS Fixed Needle – SuperFleX ™ Flexible Plunger
HP7673, 7683, 7693A and 6850ALS Removable Needle
0.63/0.47 0.155 Cone 0.5BR-AG-0.63/0.47
0.63
0.22
Cone 1BR-AG-0.63
26
0.47
0.11
Cone 5R-AG-0.47
036710
-
-
-
-
23
0.63
0.11
Cone 5R-AG-0.63
036720
-
-
-
-
001815
0.63/0.47
0.11
Cone 5R-AG-0.63/0.47
036730
-
-
-
-
001825
26
0.47
0.11
Cone 10R-AG-0.47
037715
-
-
-
-
002805
23
0.63
0.11
Cone 10R-AG-0.63
037717
-
-
-
-
002815
26
0.47
0.11
Cone 10R-AG-GT-0.47
037715
031809
-
-
-
002817
42
23
0.63
0.11
Cone 10R-AG-GT-0.63
037717
031809
-
002820
-
002818
-
42
23-26
0.63/0.47
0.11
Cone 10R-AG-0.63/0.47
037730
-
-
-
-
002825

42
23-26
0.63/0.47
0.11
Cone 10R-AG-GT-0.63/0.47
037730
031809
-
-
-
002829
25 µL
-
42
23
0.63
0.24
Cone 25R-AG-0.63
038717
-
-
-
-
003665
50 µL
-
42
23
0.63
0.24
Cone 50R-AG-0.63
038717
-
-
-
-
004665
100 µL
-
42
23
0.63
0.24
Cone 100R-AG-0.63
038717
-
-
-
-
005665
250 µL
-
42
23
0.63
0.24
Cone 250R-AG-0.63
038717
-
-
-
-
006665
HP7673, 7683, 7693A and 6850ALS Removable Needle Syringes – SuperFleX™ Flexible Plunger
10 µL
-
42
26
0.47
0.11
Cone 10RX-AG-0.47
037715
-
-
-
-
002844
10 µL
-
42
23
0.63
0.11
Cone 10RX-AG-0.63
037717
-
-
-
-
002845
0.63
0.155 Bevel 1BR-F5
034705*
-
-
-
-
000585
0.155 Bevel 1BR-FV-56
034710*
-
-
-
-
000587
HP7670 Removable Needle
1 µL
-
50
23
HP7671A-7672 Removable Needle
1 µL
-
56
23
0.63
* Plunger and needle replacement kit.
Syringes | GC Autosampler Syringes
43
Syringes | GC Autosampler Syringes
CTC Analytics
Specifications of the following syringes are matched to CTC holders to ensure proper fit and reliable functioning.
Syringes and
Accesssories
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume) (± 2 % for 0.5 μL syringes)
Borosilicate Glass Barrel Outer Diameter (OD)
0.5 μL to 100 μL = 6.5 mm (except for P/N 003700 where OD is 8 mm),
250 μL and 500 μL = 8 mm, 1 mL = 7.6 mm, 2.5 mL = 9.7 mm
Scale Length
0.5 μL = 27.05 mm, 5 μL and 10 μL = 54.1 mm, 25 μL to 2.5 mL = 60 mm
International Standards Traceability
Syringe
Volume
PTFE
Needle Needle Needle Needle
Tipped Length Gauge
OD
ID
Plunger (mm)
(mm)
(mm)
Needle
Tip
Syringe Code
Replacement
Plunger
Part No.
6 Pack
Syringe
Part No.
Syringe
Part
No.
001700
Fixed Needle
5 μL
-
50
26
0.47
0.11
Cone
5F-CTC-5/0.47C
-
-
5 μL
-
50
23
0.63
0.11
Cone
5F-C/T-5/0.63C
-
-
001981
5 μL
-
50
26
0.47
0.11
Cone
5F-C/T-5/0.47C
-
-
001982
10 μL
50
26
0.47
0.11
Cone
10F-C/T-GT-5/0.47C
031803
002976
002977
10 μL
-
50
26
0.47
0.11
Cone
10F-CTC-5/0.47C
-
-
002700
10 μL
-
50
26
0.47
0.11
Bevel
10F-CTC-5/0.47BV
-
-
002705
10 μL
-
50
23
0.63
0.11
Cone
10F-C/T-5/0.63C
-
002971
002981
10 μL
50
22
0.72
0.175
Side Hole
10F-CTC-GT-5/0.72H
031803
-
002983
10 μL
50
23
0.63
0.11
Cone
10F-C/T-GT-5/0.63C
031803
002972
002987
25 μL
50
26
0.47
0.11
Cone
25F-CTC-GT-5/0.47C
0318922
-
003700
25 μL
-
50
26
0.47
0.11
Cone
25F-C/T-0.47C
-
-
003980
25 μL
50
23
0.63
0.24
Cone
25F-C/T-GT-0.63C
031817
-
003987
100 μL
50
26
0.47
0.11
Cone
100F-CTC-GT-5/0.47C
0318261
-
005700
100 μL
50
23
0.63
0.24
Cone
100F-C/T-GT-0.63C
0318261
-
005335
250 μL
50
26
0.47
0.25
Cone
250F-CTC-GT-5/0.47C
0318926
-
006700
500 μL
50
26
0.47
0.25
Cone
500F-CTC-GT-5/0.47C
0318928
-
007700
1 mL
56
26
0.47
0.15
Side Hole
1MF-CTC-GT-HS-5/0.47H
0318441
-
008135
1 mL
56
23
0.63
0.15
Side Hole
1MF-CTC-GT-HS-5/0.63H
0318441
-
008130
2.5 mL
56
26
0.47
0.15
Side Hole
2.5MF-CTC-GT-HS-5/0.47H
0318451
-
008635
2.5 mL
56
23
0.63
0.15
Side Hole
2.5MF-CTC-GT-HS-5/0.63H
0318451
-
008630
Syringe
PTFE
Volume Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID (mm)
Needle
Tip
Syringe Code
Replace- Replace- Syringe
ment
ment
Part
Needle Plunger
No.
Part No. Part No.
Removable Needle
0.5 μL
-
50
26
0.47
0.155
Cone
0.5BNR-C/T-0.47C
033770*
-
000490
0.5 μL
-
50
23
0.63
0.155
Cone
0.5BNR-C/T-0.63C
033772*
-
000492
5 μL
-
50
23
0.63
0.11
Cone
5R-C/T-0.63C
036011
-
001984
10 μL
51.5
23
0.63
0.11
Cone
10R-C/T-GT-5.15/0.63C
037013
0318121
002965
10 μL
-
50
26
0.47
0.11
Cone
10R-C/T-5/0.47C
037010
-
002982
10 μL
-
50
23
0.63
0.11
Cone
10R-C/T-0.63C
037787
-
002984
Cone
10 μL
50
26
0.47
0.11
10R-C/T-GT-0.47C
037787
0318121
002985
25 μL
50
26
0.47
0.15
Side Hole 25R-C/T-GT-0.47H
038749
031816
003988
Side Hole 25R-C/T-GT 0.72H
25 μL
50
22
0.72
0.375
100 μL
50
26
0.47
0.2
100 μL
50
23
0.63
0.24
038420
031816
003989
100R-C/T-GT-0.47C
038732
031826
005333
Side Hole 100R-C/T-GT-0.63H
038736
031826
005337
Cone
* Plunger and needle replacement kit.
44
This selection guide can be viewed as an electronic book at sge.com/selectionguide
CTC PAL-XT and XCHA
ANGE®
For more information on
XCHANGE® on CTC PALXT contact CTC Analytics.
www.ctc.ch
Syringes and
Accessories
XCHANGE® CTC PAL-XT GC Autosam
mpler Syringes
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
Needle
ID
(mm)
Needle
Tip
Replacement Replacement
Needle
Plunger
Part No.
Part No.
Part No.
Removable Needle
10 μL
-
56
23
0.63
0.11
Cone
037021
-
2926210
25 μL
56
23
0.63
0.15
Cone
038737
2930380
2928310
2928410
50 μL
56
23
0.63
0.15
Cone
038737
2930480
100 μL
56
23
0.63
0.15
Cone
038737
2930580
2928510
250 μL
56
23
0.63
0.15
Cone
038737
2930680
2928610
500 μL
56
23
0.63
0.15
Cone
038737
2930780
2928710
1 mL
56
23
0.63
0.32
Bevel
039125
2930880
2928820
2.5 mL
56
23
0.63
0.32
Bevel
039525
2930980
2928920
5 mL
56
23
0.63
0.32
Bevel
039525
2930985
2928922
XCHANGE® syringes are removable
needle syringes change the needle
to suit your application.
Shimadzu Instruments
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume) (± 2 % for 0.5 μL and 1 μL syringes)
Borosilicate Glass Barrel Outer Diameter (OD)
6.5 mm
Scale Length
0.5 μL = 27.05 mm, 5 μL to 250 μL = 54.1 mm
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
AOC 9 Removable Needle
0.5 μL
-
50
26
0.47
0.155
Cone
0.5BR-S(9)0.47
033732*
-
000435
10 μL
-
50
26
0.47
0.11
Cone
10R-S(9)-0.47
037010
-
002885
AOC 14, 17, 20 and 20i Fixed Needle
5 μL
-
42
26
0.47
0.11
Cone
5F-S-0.47
-
-
001987
5 μL
-
42
23
0.63
0.11
Cone
5F-S-0.63
-
-
001988
50 μL
-
42
23
0.63
0.24
Cone
50F-S-0.63
-
-
004682
250 μL
42
23
0.63
0.24
Cone
250F-S-GT-0.63
-
031828
006682
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement Replacement
Needle
Plunger
Part No.
Part No.
Syringe
Part No.
AOC 14, 17, 20 and 20i Removable Needle
0.5 μL
-
42
26
0.47
0.155
Cone
0.5BR-S-0.47
033738*
-
000440
0.5 μL
-
42
23
0.63
0.155
Cone
0.5BR-S-0.63
033745*
-
000445
10 μL
-
42
26
0.47
0.11
Cone
10R-S-0.47
037745
-
002897
10 μL
-
42
23
0.63
0.11
Cone
10R-S-0.63
037747
-
002898
10 μL
42
23
0.63
0.11
Cone
10R-S-GT-0.63
037747
031798
002902
* Plunger and needle replacement kit.
For syringes to suit the Shimadzu AOC-5000 Autosampler refer to the CTC Autosampler
syringes on page 44.
Syringes | GC Autosampler Syringes
45
Syringes | GC Autosampler Syringes
PerkinElmer Instruments
SPECIFICATIONS
Syringes and
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume) (± 2 % for 0.5 µL)
Borosilicate Glass Barrel Outer Diameter (OD)
6.5 mm
Scale Length
0.5 µL and 5 µL = 27.05 mm, 50 µL = 54.1 mm
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement Replacement
Needle
Plunger
Part No.
Part No.
Syringe
Part No.
AutoSystem and Clarus 500 Fixed Needle
5 µL
-
70
26
0.47
0.15
Cone
5F-PE-0.47
-
-
001953
5 µL
-
70
23
0.63
0.15
Cone
5F-PE-0.63
-
-
001954
5 µL

70
26
0.47
0.15
Cone
5F-PE-GT-0.47
-
031807
001955
5 µL

70
23
0.63
0.15
Cone
5F-PE-GT-0.63
-
031807
001957
50 µL
-
70
23
0.63
0.24
Cone
50F-PE-0.63
-
-
004670
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle Tip
Syringe Code
Replacement
Needle and Plunger Kit
Part No.
Syringe
Part No.
AutoSystem and Clarus 500 Removable Needle
0.5 µL
-
70
26
0.47
0.155
0.5 µL
-
70
23
0.63
0.155
Beveled Cone 0.5BR-PE-0.47
Cone
0.5BR-PE-0.63
033750
000475
033765
000478
Thermo Scientific Instruments
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume) (± 2 % for 0.5 µL)
Borosilicate Glass Barrel Outer Diameter (OD)
6.5 mm
Scale Length
0.5 µL = 27.05 mm, 10 µL = 54.1 mm
International Standards Traceability
Replacement
Plunger Part No.
TriPlus
AS3000
Cone
5F-C/T-5/0.63C
-
-

-
-
-
-
001981
0.11
Cone
10F-C/T-8/0.63C
-
-

-

-
-
002989
10 µL
-
80
26
0.47
0.11
Cone
10F-C/T-8/0.47C
-
-

-

-
-
002992
10 µL
-
50
25
0.50
0.125
Cone
10F-C/T-5/0.50C
-
-




-
002967
Syringe Part No.
Replacement
Needle Part No.
0.11
0.63
6 Pack Syringe
Part No.
Needle Tip
0.63
23
AS200/800
Needle ID (mm)
23
80
AS2000
Needle OD (mm)
50
-
Syringe Code
Needle Gauge
-
PTFE Tipped
Plunger
5 µL
10 µL
Syringe Volume
Needle Length
(mm)
Model
Fixed Needle
10 µL
-
80
22
0.72
0.175
Cone
10F-C/T-8/22C
-
-

-

-
-
002974
10 µL

50
23
0.63
0.11
Cone
10F-C/T-GT-5/0.63C
-
031803

-

-
002972
002987
10 µL
-
50
23
0.63
0.11
Cone
10F-C/T-5/0.63C
-
-




002971
002981
10 µL
-
50
26
0.47
0.11
Cone
10F-C/T-5/0.47C
-
-




002986
002980
TriPlus
AS3000
AS2000
AS200/800
6 Pack Syringe
Part No.
Syringe Part No.
Cone
0.5BNR-C/T-5/0.47C 033770*
-


-
-
-
000490
0.155
Cone
0.5BNR-C/T-5/0.63C 033772*
-


-
-
-
000492
10 µL
-
50
26
0.47
0.11
Cone
10R-C/T-5/0.47C
037010
-



-
-
002982
10 µL
-
50
23
0.63
0.11
Cone
10R-C/T-5/0.63C
037787
-




-
002984
10 µL
-
80
26
0.47
0.15
Cone
10R-C/T-8/0.47C
031535
-

-

-
-
002993
Replacement
Plunger Part No.
0.155
Replacement
Needle Part No.
Needle Tip
0.47
0.63
Syringe Code
Needle ID (mm)
26
23
Needle Gauge
50
50
Needle Length
(mm)
-
PTFE Tipped
Plunger
0.5 µL
0.5 µL
Syringe Volume
Needle OD (mm)
Model
Removable Needle
* Plunger and needle replacement kit.
46
For more syringe tips view our video at sge.com/support/videos
Bruker/Varian Instruments
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume) (± 2 % for 1 µL syringes)
Borosilicate Glass Barrel Outer Diameter (OD)
1 µL = 8 mm, 10 µL = 6.5 mm, 100 µL = 8 mm
Scale Length
1 µL = 54.1 mm, 10 µL = 50.7 mm (except for 002950, 002981 and 002982
which is 54.1 mm), 100 µL = 60 mm
Syringes and
Accessories
International Standards Traceability
Syringe PTFE
VolTipped
ume
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle Syringe Code
Tip
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
-
031218
002923
8035, 8100 and 8200 Series Fixed Needle
10 µL

53
25
0.5
0.125
S/Hole
10F-GT-VA8X-2
8400/8410, CP-9010/9050 Series Fixed Needle
10 µL
-
50
26
0.47
0.11
Bevel
10F-VA8400-5/0.47
-
-
002950
10 µL
-
50
23
0.63
0.11
Cone
10F-C/T-5/0.63C
-
-
002981
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle ID
(mm)
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
0.5
0.125
031218
002926
Syringe PTFE
VolTipped
ume
Plunger
Needle Syringe Code
Tip
8000 Series Removable Needle
10 µL

50
25
Dome
10R-GT-VA80-2
037775
8035, 8100 and 8200 Series Removable Needle
1 µL
-
51
26
0.47
0.155
Cone
1BR-VA8X
034720*
-
000655
10 µL

53
25
0.5
0.125
S/Hole
10R-GT-VA8X-2
037777
031218
002924
100 µL

53
25
0.5
0.125
S/Hole
100R-GT-VA8X
038745
031824
005921
Cone
10R-C/T-5/0.47C
037010
-
002982
8400/8410, CP-9010/9050 Series Removable Needle
10 µL
-
50
26
0.47
0.11
* Plunger and needle replacement kit.
Syringes | GC Autosampler Syringes
47
Syringes | LC Manual Syringes
Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves
SPECIFICATIONS
Syringess and
ries
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
5 µL and 10 µL = 6.5 mm, 25 µL to 500 µL = 8 mm, 1 mL = 8.8 mm, 2.5 mL = 10.8 mm
Scale Length
60 mm (5 µL and 10 µL are 54.1 mm)
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement
Plunger
Part No.
6 Pack
Syringe
Part No.
Syringe
Part No.
Fixed Needle
5 µL
-
51
22
0.028"
0.17
LC
5F-LC
-
-
001301
10 µL
SuperfleX ™
-
51
22
0.028"
0.17
LC
10FX-LC
-
002330
002300
10 µL
-
51
22
0.028"
0.17
LC
10F-LC
002301
51
23
0.028"
0.17
LC
10F-LC-GT
51
22
0.028"
0.37
LC
25F-LC
10 µL
25 µL
-
-
002315
031810
-
002335
-
-
003300
004300
50 µL
-
51
22
0.028"
0.37
LC
50F-LC
-
-
100 µL
-
51
22
0.028"
0.37
LC
100F-LC
-
-
005300
250 µL
-
51
22
0.028"
0.37
LC
250F-LC
-
-
006300
500 µL
-
51
22
0.028"
0.37
LC
500F-LC
-
-
007300
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle Syringe Code
Tip
Replacement Needle
Part No.
Syringe
Part No.
002345
Removable Needle with Repeating Adaptor
10 µL
-
51
22
0.028"
0.17
LC
10R-LC-RAX
037250
25 µL
-
51
22
0.028"
0.37
LC
25R-LC-RAX
038250
003320
50 µL
-
51
22
0.028"
0.37
LC
50R-LC-RAX
038250
004320
100 µL
-
51
22
0.028"
0.37
LC
100R-LC-RAX
038250
005320
250 µL
-
51
22
0.028"
0.37
LC
250R-LC-RAX
038250
006320
500 µL
-
51
22
0.028"
0.37
LC
500R-LC-RAX
038250
007320
The blunt LC needle tip design and 51 mm needle length
are used to avoid damage to the LC valve.
LC manual Syringes
are a good choice
for general liquid
dispensing.
48
For more syringe tips view our video at sge.com/support/videos
Syringes and
Accessories
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle Syringe Code
Tip
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
Removable Needle
5 µL
-
51
22
0.028"
0.17
LC
5R-LC
036250
-
001310
10 µL
-
51
22
0.028"
0.17
LC
10R-LC
037250
-
002310
10 µL
10 µL
-
25 µL
-
51
22
0.028"
0.17
LC
10R-GT-LC
037250
031811
002313
51
22
0.028"
0.17
LC
10RX-LC
037250
-
002350
003310
51
22
0.028"
0.37
LC
25R-LC
038250
-
51
22
0.028"
0.37
LC
25R-GT-LC
038250
031815
003312
-
51
22
0.028"
0.37
LC
50R-LC
038250
-
004310
51
22
0.028"
0.37
LC
50R-GT-LC
038250
031820
004312
-
51
22
0.028"
0.37
LC
100R-LC
038250
-
005310
51
22
0.028"
0.37
LC
100R-GT-LC
038250
031825
005312
-
51
22
0.028"
0.37
LC
250R-LC
038250
-
006310
51
22
0.028"
0.37
LC
250R-GT-LC
038250
031830
006312
-
51
22
0.028"
0.37
LC
500R-LC
038250
-
007310
500 µL
51
22
0.028"
0.37
LC
500R-GT-LC
038250
031835
007312
1 mL
51
22
0.028"
0.37
LC
1MR-LC-GT
039250
031842
008105
2.5 mL
51
22
0.028"
0.37
LC
2.5MDR-LC-GT
039250
031852
008505
25 µL
50 µL
50 µL
100 µL
100 µL
250 µL
250 µL
500 µL
Users of Valco
injectors requiring
3/4” long needles,
must fit a Valco
VISF-2 adaptor.
When using the complete loop fill technique, the
syringe capacity should be greater than twice the loop
volume. The loop capacity sets the injection volume.
When using the partial loop technique, the injection
volume should be no greater than half the loop capacity.
The injection size sets the injection volume.
Syringes | LC Manual Syringes
49
Syringes | LC Autosampler Syringes
Hitachi Instruments
SPECIFICATIONS
Syringes and
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
8 mm
Scale Length
No scale (60 mm stroke)
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Front Thread
Syringe Code
Replacement
Plunger
Part No.
Syringe
Part No.
500 µL

M10 x 1.0
500C-HITACHI
031837
007660
PerkinElmer Instruments
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
50 µL to 500 µL = 8 mm, 1 mL = 9 mm, 2.5 mL = 11 mm
Scale Length
60 mm
International Standards Traceability
50
Syringe
Volume
PTFE
Tipped
Plunger
Front Thread
Syringe Code
Replacement
Plunger
Part No.
Syringe
Part No.
004995
50 µL

1/4-28 UNF
50D-CX-GT
0318221
100 µL

1/4-28 UNF
100D-CX-GT
0318271
005990
250 µL

1/4-28 UNF
250D-CX-GT
031833
006995
007995
500 µL

1/4-28 UNF
500D-CX-GT
0318381
1 mL

1/4-28 UNF
1MD-C-GT
0318441
008185
2.5 mL

1/4-28 UNF
2.5MD-C-GT
031854
008687
This selection guide can be viewed as an electronic book at sge.com/selectionguide
CTC Analytics
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
10 μL to 250 μL = 6.5mm (except P/N 003715 and P/N 006720 = 8 mm)
500 μL = 8 mm, 1 mL = 7.6 mm, 2.5 mL = 9.7 mm, 5 mL = 14 mm
Scale Length
10 μL = 54.1 mm, 25 μL to 5 mL = 60 mm
Syringes and
Accessories
International Standards Traceability
Syringe
Volume
PTFE
Needle Needle Needle Needle Needle Syringe Code
OD
ID
Tip
Tipped Length Gauge
mm)
(mm)
Plunger (mm)
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
002710
Fixed Needle
10 μL
-
51
22
0.72
0.17
LC
10F-CTC-LC
-
-
10 μL
51
22
0.72
0.17
LC
10F-CTC-GT-LC
-
031803
002715
25 μL
51
22
0.72
0.17
LC
25F-CTC-GT-LC
-
0318922
003715*
25 μL
-
51
22
0.72
0.37
LC
25F-C/T-LC
-
-
003984
50 μL
51
22
0.72
0.37
LC
50F-C/T-GT-LC
-
031821
004810
100 μL
51
22
0.72
0.17
LC
100F-CTC-GT-LC
-
0318261
005715
100 μL
51
22
0.72
0.4
LC
100F-CTC-GT-LC (0.4)
-
0318261
005720
250 μL
51
22
0.72
0.4
LC
250F-CTC-GT-LC (0.4)
-
0318926
006720*
500 μL
51
22
0.72
0.4
LC
500F-CTC-GT-LC (0.4)
-
0318928
007720
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
* Please note barrel OD is 8mm.
Syringe
Volume
PTFE
Needle Needle Needle Needle Needle Syringe Code
Tipped Length Gauge
OD
ID
Tip
Plunger (mm)
mm)
(mm)
Removable Needle
25 μL
51
22
0.72
0.37
LC
25R-C/T-GT-LC
038250
031816
003985
50 μL
51
22
0.72
0.37
LC
50R-C/T-GT-LC
038250
0318212
004830
100 μL
51
22
0.72
0.37
LC
100R-C/T-GT-LC
038250
031826
005330
250 μL
51
22
0.72
0.37
LC
250R-C/T-GT-LC
038250
031831
006330
1 mL
51
22
0.72
0.4
LC
1MR-CTC-GT-LC(0.4)
039180
0318444
008120
2.5 mL
51
22
0.72
0.4
LC
2.5MR-CTC-GT-LC(0.4)
039182
0318454
008620
5 mL
51
22
0.72
0.4
LC
5MR-CTC-GT-LC(0.4)
( )
0315235
031856
008820
CTC PAL-XT and XCHANG
GE®
For more information on
XCHANGE® on CTC PALXT contact CTC Analytics.
www.ctc.ch
XCHANGE® CTC PAL-XT LC Autosamplerr Syringes
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
Needle
ID
(mm)
Needle
Tip
Replacement Replacement
Needle
Plunger
Part No.
Part No.
Part No.
Removable Needle
10 μL
-
56
22
0.028"
0.17
LC
037221
-
2926230
25 μL
56
22
0.028"
0.17
LC
038259
2930380
2928330
2928430
50 μL
56
22
0.028"
0.17
LC
038259
2930480
100 μL
56
22
0.028"
0.17
LC
038259
2930580
2928530
250 μL
56
22
0.028"
0.375
LC
038255
2930680
2928630
500 μL
56
22
0.028"
0.375
LC
038255
2930780
2928730
1 mL
56
22
0.028"
0.375
LC
039256
2930880
2928830
2.5 mL
56
22
0.028"
0.375
LC
039556
2930980
2928930
5 mL
56
22
0.028"
0.375
LC
039556
2930985
2928932
Syringes | LC Autosampler Syringes
51
Syringes | LC Autosampler Syringes
Spark Holland Instruments
SPECIFICATIONS
Syringes and
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
250 μL = 8 mm, 1 mL = 9 mm
Scale Length
60 mm
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Front Thread
250 μL
1/4-28 UNF
1 mL
1/4-28 UNF
Syringe Code
Replacement
Plunger
Part No.
Syringe
Part No.
250D-SPARK-GT
0318348
006683
1MD-SPARK-GT
0318448
008183
Thermo Scientific Instruments
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
250 μL and 500 μL = 8 mm, 1 mL = 9 mm, 2.5 mL = 11 mm, 5 mL = 14 mm
Scale Length
No scale (60mm stroke)
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Front Thread
Syringe Code
Replacement
Plunger
Part No.
Syringe
Part No.
SP8780/8875/8880
500 μL
1/4-28 UNF
500C-THERMOSPEC
0318381
007680
2.5 mL
1/4-28 UNF
2.5MC-THERMOSPEC
031853
008660
AS100/300 and AS1000/3000/3500
250 μL
1/4-28 UNF
250C-THERMOSPEC
031833
006660
500 μL
1/4-28 UNF
500C-THERMOSPEC
0318381
007680
1 mL
1/4-28 UNF
1MC-THERMOSPEC
031844
008180
2.5 mL
1/4-28 UNF
2.5MC-THERMOSPEC
031853
008660
5 mL
1/4-28 UNF
5MC-THERMOSPEC
031856
008780
Replacement
Plunger
Part No.
Syringe
Part No.
Waters Instruments
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
8 mm
Scale Length
No scale (60 mm stroke)
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Front Thread
Syringe Code
25 μL
1/4-28 UNF
25D-WISP
031819
003990
250 μL
1/4-28 UNF
250D-WISP
031834
006690
WISP Dipper Needle
52
Needle Length
(mm)
Needle OD
(mm)
Needle ID
(mm)
Needle
Tip
121
1.587
0.5
Side Hole Cone
Description
Part No.
N-121/1.59(0.5)SH
038265
Syringes | LC Autosampler Syringes
Syringes | LC Pump High Capacity Syringes
LC Pump High Capacity Syringes
High capacity Luer Lock syringes are ideal for loop fill injection techniques when used in
conjunction with an LC tipped Luer Lock needle. They are also perfect for flushing sample
loops after injection, and priming the LC pump.
Syringes and
Accessories
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
1 mL = 9 mm, 2.5 mL = 11 mm, 5 mL = 14 mm, 10 mL = 18 mm, 25 mL = 27 mm
Scale Length
60 mm
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Termination
Syringe Code
Replacement
Plunger
Part No.
Syringe
Part No.
1 mL
Fixed Luer Lock
1MDF-LL-GT
0318441
008025
2.5 mL
Fixed Luer Lock
2.5MDF-LL-GT
031852
008425
5 mL
Fixed Luer Lock
5MDF-LL-GT
0318562
008762
10 mL
Fixed Luer Lock
10MDF-LL-GT
031864
008962
25 mL
Fixed Luer Lock
25MDF-LL-GT
031874
009463
Pack
Size
Part No.
2
200010
Description
Luer Lock Valve Adaptor
For complete loop fill, the syringe capacity should be
greater than twice the loop volume. The loop capacity
sets the injection volume. For partial loop fill, the
injection volume should be no greater than half the loop
capacity. The injection size sets the injection volume.
Syringes | LC Pump High Capacity Syringes
53
Syringes | Instrument Syringes
1 - 100 mL PTFE Tipped Plunger
Suitable for Instrument, Dispenser and Manual Use
Syringes and
es
Accessories
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
1 mL = 9 mm, 2.5 mL = 11 mm, 5 mL = 14 mm, 10 mL = 18 mm,
25 mL = 27 mm, 50 mL = 32.8 mm, 100 mL = 40.8 mm
Scale Length
1 – 25 mL = 60 mm, 50 mL = 84.2 mm, 100 mL = 104 mm
Thread in Plunger Button
6-32 UNC
International Standards Traceability
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Syringe Code
Replacement Replacement Syringe
Needle
Plunger
Part No.
Part No.
Part No.
1 mL
50
22
0.72
0.37
Bevel
1MDF-GT
-
0318441
008102
2.5 mL
50
22
0.72
0.37
Bevel
2.5MDF-GT
-
031852
008502
Fixed Needle
Removable Needle
1 mL
50
23
0.63
0.32
Bevel
1MR-GT
039110
031842
008100*
2.5 mL
50
23
0.63
0.32
Bevel
2.5MDR-GT
039110
031852
008500
5 mL
50
23
0.63
0.32
Bevel
5MDR-GT
031516
031856
008700
10 mL
50
23
0.63
0.32
Bevel
10MDR-GT
031516
031862
008900
1 mL
-
-
-
-
Luer Tip
1MF-LT-GT
-
031842
008020*
2.5 mL
-
-
-
-
Luer Tip
2.5MDF-LT-GT
-
031852
008420
Fixed Luer Tip
Fixed Luer Lock
1 mL
-
-
-
-
Luer Lock
1MDF-LL-GT
-
0318441
008025
2.5 mL
-
-
-
-
Luer Lock
2.5MDF-LL-GT
-
031852
008425
5 mL
-
-
-
-
Luer Lock
5MDF-LL-GT
-
0318562
008762
10 mL
-
-
-
-
Luer Lock
10MDF-LL-GT
-
031864
008962
25 mL
-
-
-
-
Luer Lock
25MDF-LL-GT
-
031874
009463
Removable Luer Lock
5 mL
-
-
-
-
Luer Lock
5MDR-LL-GT
-
031856
008760
10 mL
-
-
-
-
Luer Lock
10MDR-LL-GT
-
031862
008960
25 mL
-
-
-
-
Luer Lock
25MR-LL-GT
-
031870
009462
50 mL
-
-
-
-
Luer Lock
50MR-LL-GT
-
0312170
009660*
100 mL
-
-
-
-
Luer Lock
100MR-LL-GT
-
0312176
009760*
* No thread in plunger stem of syringe part numbers 008100, 008020, 009660 and 009760.
The Luer Lock termination provides
extra security when
using Luer Lock
needles and fittings, syringe filters
and pump priming.
54
For more syringe tips view our video at sge.com/support/videos
General - Replacement for Hamilton Pump Syringes
Syringes and
Accessories
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
25 µL to 500 µL = 8mm, 1 mL = 9 mm, 2.5 mL = 11 mm, 5 mL = 14 mm,
10 mL = 18 mm, 25 mL = 27 mm
Scale Length
60 mm
Thread in Plunger Button
6-32 UNC
International Standards Traceability
C and CX Syringes
Syringe
Volume
PTFE Tipped
Plunger
Termination
Syringe Code
Replacement
Plunger
Part No.
Syringe
Part No.
25 µL
1/4-28 UNF
25D-CX
0318191
003995
50 µL
1/4-28 UNF
50D-CX
0318221
004995
100 µL
1/4-28 UNF
100D-CX
0318271
005990
250 µL
1/4-28 UNF
250D-CX
031833
006995
500 µL
1/4-28 UNF
500D-CX
0318381
007995
1 mL
1/4-28 UNF
1MD-C
0318441
008185
2.5 mL
1/4-28 UNF
2.5MD-C
031854
008687
5 mL
1/4-28 UNF
5MD-C
0318562
008787
10 mL
1/4-28 UNF
10MD-C
031864
008987
Replacement
Plunger
Part No.
Syringe
Part No.
004232
LL and LLX Syringes
Syringe
Volume
PTFE
Tipped
Plunger
Termination
Syringe Code
50 µL
Luer Lock
50F-LLX-GT
0318221
100 µL
Luer Lock
100F-LLX-GT
0318271
005232
250 µL
Luer Lock
250F-LLX-GT
031833
006232
500 µL
Luer Lock
500F-LLX-GT
0318381
007232
1 mL
Luer Lock
1MDF-LL-GT
0318441
008025
2.5 mL
Luer Lock
2.5MDF-LL-GT
031852
008425
5 mL
Luer Lock
5MDF-LL-GT
0318562
008762
10 mL
Luer Lock
10MDF-LL-GT
031864
008962
25 mL
Luer Lock
25MDF-LL-GT
031874
009463
Syringes | Instrument Syringes
55
Syringes | Instrument Syringes
Shimadzu Total Organic Carbon Analyzer – TOC5000
SPECIFICATIONS
Syringes and
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
250 µL = 8 mm
Scale Length
60 mm
International Standards Traceability
Syringe
Volume
PTFE Tipped
Plunger
Termination
250 µL
1/4-28 UNF
Syringe Code
250C-SHIM (TOC)
Replacement
Plunger
Part No.
Syringe
Part No.
031832
006680
Replacement
Plunger
Part No.
Syringe
Part No.
Zymark
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
5 mL = 14 mm, 10 mL = 18 mm
Scale Length
60 mm
International Standards Traceability
Syringe
Volume
56
PTFE Tipped
Plunger
Termination
Syringe Code
5 mL
Slotted Luer Lock
5MD-ZYMARK-GT
0318562
008792
10 mL
Slotted Luer Lock
10MD-ZYMARK-GT
031864
008992
Syringes | Instrument Syringes
Syringes | Special Purpose Syringes
MEPS™ - Micro Extraction by Packed Sorbent
For more information about MEPS™ - Micro SPE, please refer to pages 222-225.
Syringes and
Accessories
Choose your MEPS™ syringe
The current range of syringes may be used manually or in autosamplers. To maximize
flexibility, MEPS™ syringes are supplied without a needle. MEPS™ BIN (barrel insert needle )
options are listed on page 225.
Syringe
Volume
PTFE
Tipped
Plunger
Autosampler
Syringe
Scale
Length
(mm)
Syringe
Barrel OD
(mm)
Replacement
Plunger
Part No.
Syringe
Part No.
100 µL
Agilent Instrument 7693A
54.1
6.5
0318263
005292
100 µL
Shimadzu Instruments AOC20i
54.1
6.7
0318274
005293
100 µL
CTC Analytics, HTA 300APlus, Thermo Scientific and
Varian 8400 systems
60
6.7
031826
005291
250 µL
Agilent Instruments 7693A
54.1
6.5
0318303
006293
250 µL
Shimadzu Instruments AOC20i
54.1
6.7
0318305
006294
250 µL
HTA 300APlus, Thermo Scientific and Varian 8400
systems
60
6.7
031831
006291
250 µL
CTC Analytics systems
60
7.8
0318301
006292
eVol® MEPS™
eVol® is ideal for use with MEPS™. The eVol® custom programming function allows manual
MEPS™ to be automated - the sampling, processing, extraction and injection steps are
performed using the same syringe.
Refer to pages 21-24 for more information about eVol®.
Syringe
Volume
PTFE Tipped Description
Plunger
Replacement Plunger
Part No.
Syringe
Part No.
50 µL
eVol® XCHANGE™ Syringe for MEPS™
2910382
2910027
500 µL
eVol® XCHANGE™ Syringe for MEPS™
2910384
2910026
Syringes | Special Purpose Syringes
57
Syringes | Special Purpose Syringes
GC On-Column
SPECIFICATIONS
Syringes and
Accessories
Accuracy and Reproducibility
0.5 µL = ± 2%, 5 µL and 10 µL = ± 1% (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
0.5 µL = 8 mm, 5 µL and 10 µL = 6.5 mm
Scale Length
0.5 µL = 63.7 mm, 5 µL and 10 µL = 54.1 mm
International Standards Traceability
A range of popular on-column syringes are
available for general purpose applications.
An extended range of instrument specific
syringes is also available for most common
on-column inlets.
When selecting an on-column syringe,
the needle Outside Diameter (OD) must
be smaller than the Inside Diameter (ID) of
the GC capillary column. Care must also be
taken to select the correct needle length
to suit the on-column injector. Wherever
possible, a sheathed needle should be
used for maximum needle strength and
protection.
Types of needles offered:
• All fused silica or all stainless steel.
• Sheathed fused silica or sheathed
stainless steel.
Fused silica needles are coated with
polyimide and should not be operated
above 360 °C.
58
This selection guide can be viewed as an electronic book at sge.com/selectionguide
General GC On-Column Syringes
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Material
Syringe Code
0.5 µL
100
-
0.23
0.1
0.5 µL
70
26
0.47
0.5 µL
75
-
0.23
5 µL
100
-
0.17
5 µL
100
-
0.17
10 µL
100
-
0.17
Replacement
Needle
Part No.
Syringe
Part No.
Sheathed
Stainless Steel
0.5BR-OC-100S
033610*
000372
0.1
0.1
Stainless Steel
0.5BR-OC-7/0.47
033630*
000376
Stainless Steel
0.5BR-OC-CE-7.5
033620*
000380
0.1
Silica
5R-OC-100VS
036610
001552
0.1
Sheathed Silica
5R-OC-100SVS
036635
001554
0.1
Silica
10R-OC-100VS
037610
002520
Syringes and
Accessories
* Plunger and needle replacement kits.
Instrument Specific GC On-Column Syringes
Syringe
Volume
PTFE
Tipped
Plunger
Needle
Length
(mm)
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Material
Syringe Code
Replacement
Needle
Part No.
Replacement
Plunger
Part No.
Syringe
Part No.
Agilent Instruments
5 µL
-
50
0.19
0.11
Stainless Steel
5R-OC-5/0.19
036701
-
001585
5 µL
-
50
0.23
0.11
Stainless Steel
5R-OC-5/0.23
036703
-
001587
0.19
0.11
Sheathed
Stainless Steel
5R-OC-VAS
036651
-
001565
0.1
Silica
5R-OC-100VS
036610
-
001552
000380
Bruker/Varian Instruments
5 µL
-
107
PerkinElmer Instruments
5 µL
-
100
0.17
0.5 µL
-
75
0.23
0.1
Stainless Steel
0.5BR-OC-CE-7.5
033620*
-
5 µL
-
75
0.23
0.11
Stainless Steel
5R-OC-CE
036675
-
001560
10 µL

75
0.23
0.11
Stainless Steel
10R-GT-OC-CE
037675
031811
002500
-
95
0.27
0.11
Sheathed
Stainless Steel
5R-OCI5-0.27
036685
-
001570
Carlo Erba
Please note the
GC
On-Column
Syringes are manual syringes with
needle specifications to suit specific instruments.
They are not for
use with autosamplers.
SGE (OCI-5)
5 µL
Shimadzu Instruments
5 µL
-
50
0.19
0.11
Stainless Steel
5R-OC-5/0.19
036701
-
001585
5 µL
-
50
0.23
0.11
Stainless Steel
5R-OC-5/0.23
036703
-
001587
* Plunger and needle replacement kits.
Syringes | Special Purpose Syringes
59
Syringes | Special Purpose Syringes
0.5 L to 2 L Jumbo
Syringes and
Accessories
SPECIFICATIONS
Accuracy and Reproducibility
± 2 % (dispensed volume)
Acrylic Barrel Outer Diameter (OD)
0.5 L = 70 mm, 1 L = 100 mm and 2 L = 130 mm
Scale Length
0.5 L = 179.2 mm, 1 L = 159.1 mm and 2 L = 179 mm
International Standards Traceability
• Compatible with a range of fittings; has
a 7/16" UNEF thread and designed to be
used with Luer Lock fittings and needles.
For the range of SGE Luer Lock needles
refer to page 67.
• Refer to pages 40 to 42 for the range of
valves suitable for use with these syringes.
• Designed for holding and dispensing large
volumes of gas.
• Heavy duty acrylic barrels.
• Easy access to sample for the addition of
standards or removal of subsample via
secondary port.
• Plunger stem is removable for ease of
transportation and storage.
• Ideal for calibration of medical equipment
such as respirators and spirometers, and for
stack and air sampling.
Syringe
Volume
Barrel
Length
(mm)
Barrel
OD
(mm)
Major Scale
Divisions
(mL)
Minor Scale Syringe Code
Divisions
(mL)
Replacement
Plunger O-ring
Part No.
Syringe
Part No.
0.5 L
245
70
50
25
500MAR-LL-GT
032527
009910
1L
245
100
100
50
1000MAR-LL-GT
032532
009920
2L
245
130
200
100
2000MAR-LL-GT
032537
009930
Jumbo Syringe Accessories
Description
Part No.
Luer Lock Adaptor
031902
Cover Nut (packet of 5)
032044
Sealing CS Septa (packet of 50)
041822
MSV Syringe Valve Connector
030930
I flow Two Port Standard Valve*
030200
*Other valve configurations available, see pages 40 to 42.
60
For more syringe tips view our video at sge.com/support/videos
Gas Sealing Gland
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
8 mm
Scale Length
60 mm
Sy
Syringes
and
A
Accessories
International Standards Traceability
• A gas sealing gland (a gas tight, high
pressure PTFE seal) is used at the plunger
end of the syringe barrel.
• Ideal for applications requiring high or low
temperature function.
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
• These syringes are designed to avoid cold
flow deformation and leakage sometimes
associated with PTFE tipped plungers in low
temperature applications.
• Plungers are not interchangeable.
Needle Syringe Code
Tip
Replacement
Needle
Part No.
Syringe
Part No.
Fixed Needle
25 µL
50
25
0.5
0.2
Bevel
25F-GSG
-
003600
50 µL
50
25
0.5
0.2
Bevel
50F-GSG
-
004600
100 µL
50
25
0.5
0.2
Bevel
100F-GSG
-
005600
250 µL
50
25
0.5
0.2
Bevel
250F-GSG
-
006600
500 µL
50
25
0.5
0.2
Bevel
500F-GSG
-
007600
Removable Needle
25 µL
50
25
0.5
0.2
Bevel
25R-GSG
038110
003610
50 µL
50
25
0.5
0.2
Bevel
50R-GSG
038110
004610
100 µL
50
25
0.5
0.2
Bevel
100R-GSG
038110
005610
250 µL
50
25
0.5
0.2
Bevel
250R-GSG
038110
006610
500 µL
50
25
0.5
0.2
Bevel
500R-GSG
038110
007610
Syringes | Special Purpose Syringes
61
Syringes | Special Purpose Syringes
Headspace/Soil Gas
SPECIFICATIONS
Syringes and
Accessories
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
5 mL = 14 mm and 10 mL = 18mm
Scale Length
60 mm
International Standards Traceability
Syringe
Volume
Probe
Length
(mm)
Needle
Gauge
5 mL
60
-
10 mL
60
23
Probe
OD
(mm)
Probe
ID
(mm)
Needle
Tip
Syringe Code
Spare
Probes
Pkt 1
Spare
Needles
Pkt 5
1.587
0.75
1.587
0.75
1.587
0.75
Side Hole
0.63
0.32
Bevel
Replacement
Plunger
Part No.
Syringe
Part No.
-
5MDR-HSV
031571
-
10MDR-HSV
031571
039802
031856
008775*
039802
031862
008975*
-
-
-
-
031571
-
-
-
-
039802
Replacement
Needle
Part No.
Syringe
Part No.
1M-BP
0315720
008170
1M-BP (0.36)H
0315722
008171
Replacement Probes
-
60
Replacement Needles
-
50
* Syringe supplied with probe and needle.
High Pressure
SPECIFICATIONS
Accuracy and Reproducibility
± 1 % (dispensed volume)
Borosilicate Glass Barrel Outer Diameter (OD)
9 mm
Scale Length
60 mm
International Standards Traceability
• Fitted with a gas tight ON/OFF valve.
• Designed for high pressure gas sampling – rated to 500 psi/1700 kPa.
62
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
1 mL
70
23
0.63
0.37
Bevel
1 mL
70
23
0.63
0.36
Side Hole
Syringe Code
Syringes | Special Purpose Syringes
Syringes | Syringe Accessories
Repeating Adaptor (RAX)
The SGE Repeating Adaptor (RAX) ensures
reproducibility of sample volumes with
repeatedly accurate and precise injections.
The RAX is suitable for use on syringes with
capacities from 0.5 µL through to 500 µL. It
has easy to use finger grips and can be set
to any desired volume. The RAX can be used
as added protection against both plunger
blowout at elevated pressures and plunger
bending. The flat sides allow it to sit securely
on the bench with the needle in a raised
position helping to prevent damage. The RAX
is supplied with an innovative double-ended
tool to facilitate assembly. It is easily and quickly
installed, and if required, removed, replaced
and even swapped between syringes.
Description
Syringes and
Accessories
Part No.
Repeating Adaptor RAX
031930
Syringe Racks
Syringe racks organize your syringes and
ensure that they do not roll off the bench
or top of the instrument and break. A must
for every laboratory.
Description
Part No.
Syringe rack holds 6 syringes
031776
Syringe rack holds 6 XCHANGE® syringes
031786
Syringes | Syringe Accessories
63
Syringes | Syringe Accessories
Heated Syr
Syringe Cleaner
Ensure organic sample
residues are vaporized
out of the needle,
preventing ghost peaks
and cross contamination,
by using the SGE heated
syringe cleaner.
Syringes and
Accessories
The heated syringe cleaner is especially
useful for NanoVolume syringes where the
entire sample is confined to the needle.
Ghost peaks or crosscontamination can be
caused by a ‘dirty’
needle. Using the
SGE heated syringe
cleaner can eliminate
this.
Operation is simple. Insert the needle
through the septum into the heated zone,
hold for approximately 30 seconds and then
pump the plunger a few times to vaporize
contaminants away. The device will accept
needles up to 1 mm OD and 100 mm long.
The cleaner has a very short warm-up
period; it takes approximately 20 minutes to
reach the operating temperature (250 °C).
The unit is thermostatically controlled for
continuous use if required.
A vacuum source of approximately 10 Torr
from a water pump or mechanical pump
should be connected to the unit.
Description
Part No.
110-120 V Syringe Cleaner
031780
220-240 V Syringe Cleaner
031781
Needle Cleaning Kit
Everything needed for thorough needle
cleaning. A range of stylet wires, tweezers
for holding the wires and a non-ionic
surfactant material are provided in a
convenient package.
Description
Part No.
Needle Cleaning Kit
Kit contains:
Tube of Stylet Wires 150 mm x 0.10 mm OD
Tube of Stylet Wires 150 mm x 0.15 mm OD
Tube of Stylet Wires 150 mm x 0.20 mm OD
20 mL Cleaning Solution Concentrate
Tweezers
031782
Stylet Wires
Stylet wires are used for cleaning the inside
of needles and are available in 3 sizes – check
the needle internal diameter of the syringe
Description
64
to select the suitable wires (the needle ID is
listed for syringes throughout this selection
guide).
Pack Size
Part No.
Stylet Wires 150 mm x 0.10 mm OD
5
031745
Stylet Wires 150 mm x 0.15 mm OD
5
031746
Stylet Wires 150 mm x 0.20 mm OD
5
031747
Syringes | Syringe Accessories
Syringes | Replacement Guide
NanoVolume Syringe Plunger and Needle Kits
Kits are available for 500 – 5000 nL (0.5 µL – 5.0 µL) NanoVolume syringes. The kits are
supplied with a matched plunger and needle, both must be replaced together. A list of
replacement kits is below. Find the SGE syringe part number to determine the appropriate
replacement plunger and needle kit.
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID (mm)
0.5 µL Syringes, 6.5 mm OD Barrel
50
23
0.63
0.155
50
23
0.63
0.155
50
26
0.47
0.155
0.5 µL Syringes, 8mm OD Barrel
70
23
0.63
0.1
70
23
0.63
0.1
100
0.23
0.1
100
0.23
0.1
75
26
0.23
0.1
70
26
0.47
0.1
1 µL Syringes, 8 mm OD Barrel
50
23
0.63
0.155
50
23
0.63
0.155
70
23
0.63
0.155
115
23
0.63
0.155
70
23
0.63
0.155
70
26
0.47
0.155
5 µL Syringes, 8 mm OD Barrel
50
23
0.63
0.365
50
23
0.63
0.365
70
23
0.63
0.365
70
23
0.63
0.365
115
23
0.63
0.365
Needle Description
Tip
Syringe
Part No.
Replacement
Plunger/
Needle Kit
Part No.
Cone
Bevel
Cone
NP0.5BN-5/0.63C
NP0.5BN-5/0.63BV
NP0.5BN-5/0.47C
000300
000301
000303
033010
033011
033012
Cone
Bevel
Cone
Cone
Cone
Cone
NP0.5B-7C
NP0.5B-7BV
NP0.5B-OC-10/0.23
NP0.5B-OC-10/0.23T (Sheathed)
NP0.5B-OC-7.5/0.23
NP0.5B-OC-7/0.47
000310
000311
000372
000380
000376
033057
033060
033605
033610
033620
033630
Cone
Bevel
Cone
Cone
Bevel
Cone
NP1B-5C
NP1B-5BV
NP1B-7C
NP1B-11.5C
NP1B-7BV
NP1B-OC-7/0.47
000500
000501
000505
000510
000506
000570
034055
034056
034057
034059
034060
034610
Cone
Bevel
Cone
Bevel
Cone
NP5B-5C
NP5B-5BV
NP5B-7C
NP5B-7BV
NP5B-11.5C
000800
000801
000802
000803
000804
035055
035056
035057
035058
035059
Syringes and
Accessories
When
replacing
the plunger and
needle follow the
instructions
included in the kit –
the front cover nut
must be loosened
before removing
the plunger.
Autosampler NanoVolume Syringe Plunger and Needle Kits
Syringe
Volume
Needle
Length
(mm)
Needle
Gauge
Needle
OD
(mm)
Needle
ID
(mm)
Needle
Tip
Description
Syringe
Part No.
Replacement
Plunger/
Needle Kit
Part No.
50
23
0.63
0.155
Bevel
NP1B-F5
000585
034705
56
23
0.63
0.155
Bevel
NP1B-FV-56
000587
034710
033708
Agilent 7670
1 µL
Agilent 7672
1 µL
Agilent 7673, 7683 and 6850 ALS Syringes
0.5 µL
42
26
0.47
0.155
Cone
NP0.5B-AG-0.47
000400
0.5 µL
42
23
0.63
0.155
Cone
NP0.5B-AG-0.63
000410
033715
0.5 µL
42
23/26
0.63/0.47
0.155
Cone
NP0.5B-AG-0.63/0.47
000415
033730
1 µL
42
23
0.63
0.22
Cone
NP1B-AG-0.63
000610
034715
CTC/Leap and Thermo Scientific
0.5 µL
50
26
0.47
0.155
Cone
NP0.5BN-C/T-0.47C
000490
033770
0.5 µL
50
23
0.63
0.155
Cone
NP0.5BN-C/T-0.63C
000492
033772
PerkinElmer - AutoSystem and Clarus 500
0.5 µL
70
26
0.47
0.155
000475
033750
0.5 µL
70
23
0.63
0.155
Cone/Bevel NP0.5B-PE-0.47
Cone
NP0.5B-PE-0.63
000478
033765
26
0.47
0.155
Cone
NP0.5B-S(9)-0.47
000435
033732
Shimadzu - AOC 9
0.5 µL
50
Shimadzu - AOC 14, 17, 20 and 20i
0.5 µL
42
26
0.47
0.155
Cone
NP0.5B-S-0.47
000440
033738
0.5 µL
42
23
0.63
0.155
Cone
NP0.5B-S-0.63
000445
033745
0.47
0.155
Cone
NP1B-VA8X
000655
034720
Varian 8035, 8100 and 8200
1 µL
51
26
Syringes | Replacement Guide
65
Syringes | Replacement Guide
Needles
Syringes and
Accessories
For needles for
5 µL eVol® syringes
refer to page 24.
66
A variety of replacement needles are available for each syringe capacity. The needle length,
gauge and tip style can be changed to optimize the syringe for a wide range of applications.
For tips on needle selection refer to pages 27-28.
Needle
Length (mm)
5 µL Syringe
42
42
42
50
50
50
50
50
50
50
50
50
51 (2")
70
70
70
70
75
75
95
100
100
107
110
115
115
10 µL Syringe
42
42
42
42
42
50
50
50
50
50
50
50
50
50
50
50
50
51 (2")
53
53
56
56
70
70
70
70
70
75
75
75
100
105
115
115
Gauge
Needle
OD (mm)
Needle ID
(mm)
Tip
Style
26
23/26
23
26
26
26
26
26
23
22
26
26
26
23
26
26
0.47
0.63/0.47
0.63
0.17
0.19
0.23
0.47
0.47
0.47
0.47
0.47
0.63
0.028"
0.47
0.47
0.47
0.63
0.17
0.23
0.27
0.17
0.17
0.19
0.17
0.47
0.47
0.11
0.11
0.11
0.1
0.1
0.11
0.11
0.11
0.11
0.11
0.11
0.11
0.17
0.11
0.11
0.11
0.11
0.1
0.1
0.11
0.1
0.1
0.1
0.1
0.11
0.11
Cone
Cone
Cone
On-Column
On-Column
On-Column
Bevel
Cone
Dome
Sheathed/Bevel
Side Hole/Dome
Cone
LC
Bevel
Cone
Dome
Cone
On-Column
On-Column
On-Column
On-Column
On-Column
On-Column
On-Column
Bevel
Cone
26
26
23/26
23
23
26
26
26
26
26
25
25
25
25
23
23
23
22
25
23
23
22
26
26
26
23
22
26
26
26
0.47
0.47
0.63/0.47
0.63
0.63
0.47
0.47
0.47
0.47
0.47
0.5
0.5
0.5
0.5
0.63
0.63
0.63
0.028"
0.5
0.63
0.63
0.028"
0.47
0.47
0.47
0.63
0.028"
0.17
0.23
0.47
0.17
0.17
0.47
0.47
0.11
0.11
0.11
0.11
0.11
0.11
0.11
0.11
0.11
0.11
0.11
0.11
0.12
0.2
0.11
0.11
0.11
0.17
0.11
0.11
0.11
0.17
0.11
0.11
0.11
0.11
0.17
0.1
0.1
0.11
0.1
0.11
0.11
0.11
Cone
Cone
Cone
Cone
Cone
Bevel
Cone
Dome
Sheathed/Bevel
Side Hole/Dome
Bevel
Dome
LC
Side Hole/Dome
Bevel
Cone
Cone
LC
Side Hole/Dome
Side Hole/Cone
Cone
LC
Bevel
Cone
Sheathed/Bevel
Cone
LC
On-Column
On-Column
Dome
On-Column
On-Column
Bevel
Cone
Needle Code
Pack
Size
Part No.
N5-AG-0.47
N5-AG-0.63/0.47
N5-AG-0.63
N5-OC-5/0.17VS
N5-AG-OC-0.19
N5-AG-OC-0.23
N5-5
N5-5C
N5-5D
N5-5T
N5-5H
N5-5/0.63C
N5-LC
N5-7
N5-7C
N5-7D
N5-7-0.63C
N5-OC-7.5/0.17VS
N5-OC-7.5/0.23
N5-OC-9.5/0.27 SSS
N5-OC-10/0.17VS
N5-OC-10/0.17SVS
N5-OC-10.7/0.19S
N5-OC-11/0.17VS
N5-11.5
N5-11.5C
2
2
2
2
2
2
5
2
2
2
2
2
5
5
2
2
2
2
2
2
2
2
2
2
5
2
036710
036730
036720
036603
036701
036703
036110
036010
036510
036310
036410
036011
036250
036130
036030
036530
036031
036605
036675
036685
036610
036635
036651
036625
036160
036060
N10-AG-0.47
N10-S-0.47
N10-AG-0.63/0.47
N10-AG-0.63
N10-S-0.63
N10-5
N10-5C
N10-5D
N10-5T
N10-5H
N10-VA8035-II
N10-VA8000-II
N10-WLC
N10-VA800H-II
N10-5/0.63
N 10-5/0.63C
N10-C/T-5/0.63C
N10-LC
N10-VA8X00H-II
N10-VA8X00H-0.63-II
N10-5.6/0.63C
N10-5.6/22LC
N10-7
N10-7C
N10-7T
N10-7/0.63C
N10-LC-7
N10-OC-7.5/0.17VS
N10-OC-7.5/0.23
N10-7.5D
N10-OC-10/0.17VS
N10-VA8035-0.17-II
N10-11.5
N10-11.5C
2
2
2
2
2
5
2
2
2
2
2
2
5
1
5
2
2
5
1
2
2
5
5
2
2
2
5
2
2
2
2
2
5
2
037715
037745
037730
037717
037747
037110
037010
037510
037310
037410
037776
037775
037260
037780
037111
037011
037787
037250
037777
037779
037021
037221
037130
037030
037330
037031
037270
037605
037675
037540
037610
037778
037160
037060
This selection guide can be viewed as an electronic book at sge.com/selectionguide
Needle
Gauge
Needle
Needle ID
Length (mm)
OD (mm)
(mm)
25 - 500 µL Syringe and 50 µL eVol® Syringe
42
23
0.63
0.24
50
26
0.47
0.2
50
25
0.5
0.2
50
25
0.5
0.2
50
25
0.5
0.2
50
25
0.5
0.2
50
25
0.5
0.2
50
23
0.63
0.15
50
23
0.63
0.15
50
23
0.63
0.24
50W
25
0.5
0.2
51 (2")
22
0.028"
0.37
53
25
0.5
0.15
56
23
0.63
0.15
56
22
0.028"
0.17
56
22
0.028"
0.37
70
25
0.5
0.2
70
25
0.5
0.2
70
25
0.5
0.2
70
25
0.5
0.2
70
23
0.63
0.24
70
22
0.028"
0.37
80
25
0.5
0.2
115
25
0.5
0.2
115
25
0.5
0.2
115
25
0.5
0.2
115
23
0.63
0.24
180
23
0.63
0.24
1 - 2.5 mL Syringe and 500 µL eVol® Syringe
50
25
0.5
0.2
50
23
0.63
0.32
50
23
0.63
0.32
50
23
0.63
0.32
50
22
0.028"
0.37
51 (2")
22
0.028"
0.37
56
23
0.63
0.32
56
22
0.028"
0.375
70
23
0.63
0.32
115
23
0.63
0.32
180
23
0.63
0.32
5-10 mL Syringe
50
24
0.5
0.2
50
23
0.63
0.32
51 (2")
22
0.028"
0.37
70
23
0.63
0.32
Luer Lock Needles
50
25
0.5
0.2
50
23
0.63
0.32
50
23
0.63
0.32
50
19
1.07
0.65
50
19
1.07
0.65
50
18
1.27
0.8
50
16
1.57
1.1
50
14
2.1
1.6
51 (2")
22
0.028"
0.37
70
23
0.63
0.32
70
23
0.63
0.32
70
19
1.07
0.65
70
18
1.27
0.8
70
16
1.57
1.1
115
23
0.63
0.32
115
19
1.07
0.65
115
18
1.27
0.8
115
16
1.57
1.1
115
14
2.1
1.6
Tip
Style
Needle Code
Pack
Size
Part No.
Cone
Cone
Bevel
Dome
LC
Side Hole/Dome
PTFE Coated
Bevel
Cone
Bevel
Sheathed/Bevel
LC
Side Hole/Dome
Cone
LC
LC
Bevel
Cone
Dome
Side Hole/Dome
Bevel
LC
Cone
Bevel
Cone
Side Hole/Dome
Bevel
Bevel
N25/500-AG-0.63
N25/500-C/T-5/0.47C
N25/500-5
N25/500-5D
N25/500-WLC
N25/500-5H
N25/500-5P
N25/500-C/T-5/0.63
N25/500-C/T-5/0.63C
N25/500-5/0.63
N25/500-5T
N25/500-LC
N25/500-VAR-5.3/0.5H
N25/500-5.6/0.63C
N25/500-5.6/22(0.17)LC
N25/500-5.6/22(0.375)LC
N25/500-7
N25/500-7C
N25/500-7D
N25/500-7H
N25/500-7/0.63
N25/500-LC-7
N25/500-C/T-8/0.5C
N25/500-11.5
N25/500-11.5C
N25/500-11.5H
N25/500-11.5/0.63
N25/500-NMR-18/0.63BV
2
2
5
2
5
2
2
5
2
5
2
5
1
2
5
5
5
2
2
2
5
5
3
5
2
2
5
2
038717
038732
038110
038510
038260
038410
038910
038730
038735
038111
038310
038250
038745
038737
038259
038255
038130
038030
038530
038430
038131
038270
031536
038160
038060
038460
038161
038138
LC
Bevel
Dome
Side Hole/Dome
Bevel
LC
Bevel
LC
Bevel
Bevel
Bevel
NM1/2.5-WLC
NM1/2.5-5
NM1/2.5-5/0.63D
NM1/2.5-5/0.63H
NM1/2.5-5/22BV
NM1/2.5-LC
NM1/2.5-5.6/0.63BV
NM1/2.5-5.6/22LC
NM1/2.5-7
NM1/2.5-11.5
NM1/2.5-NMR-18/0.63BV
5
5
2
2
5
5
5
5
5
5
2
039260
039110
039116
039120
039115
039250
039125
039256
039130
039160
039138
NM5/10-WLC
NM5/10-5
NM5/10-LC
NM5/10-7
5
2
5
5
0315234
031516
0315233
031521
NLL-WLC
NLL-5/23
NLL-5/23H
NLL-5/19
NLL-5/19H
NLL-5/18
NLL-5/16
NLL-5/14
NLL-LC
NLL-7/23
NLL-7/23H
NLL-7/19
NLL-7/18
NLL-7/16
NLL-11.5/23
NLL-11.5/19
NLL-11.5/18
NLL-11.5/16
NLL-11.5/14
2
5
2
5
2
5
5
5
2
5
2
5
5
5
5
5
5
5
5
039897
039802
039803
039822
039823
039842
039862
039880
039895
039807
039808
039827
039847
039867
039811
039831
039851
039871
039891
LC
Bevel
LC
Bevel
LC
Bevel
Side Hole/Dome
Bevel
Side Hole/Dome
Bevel
Bevel
Bevel
LC
Bevel
Side Hole/Dome
Bevel
Bevel
Bevel
Bevel
Bevel
Bevel
Bevel
Bevel
Syringes | Replacement Guide
Syringes and
Accessories
67
Syringes | Replacement Guide
Syringe Components
Description
Syringes and
Accessories
Pack Size
Part No.
Replacement Luer Lock Fitting (includes Kel-F ® Luer Cone and threaded Metal Adaptor)
1
031902
Replacement Kel-F ® Luer Cones
2
031903
Replacement PTFE Plunger Seal (supplied with tool) for 0.5 µL NanoVolume syringes with 8 mm OD
Barrels
1
032002
Replacement PTFE Plunger Seal (supplied with tool) for 0.5 µL NanoVolume syringes with 6.5 mm OD
Barrels and 1 µL NanoVolume syringes
1
032004
Replacement PTFE Plunger Seal (supplied with tool) for 5 µL NanoVolume syringes
1
032006
Replacement Needle Seals 5 µL Syringes
2
032012
Replacement Needle Seals 10 µL Syringes
2
032014
Replacement Needle Seals 15 to 500 µL Syringes
2
032016
Replacement Needle Seals 1 to 2.5 mL Syringes
2
032018
Replacement Needle Springs
10
032030
Front Cover Nut for Removable Needle Syringes with 6.5 mm OD Barrel
2
032040
Front Cover Nut for Removable Needle Syringes with 8 mm OD Barrel
2
032042
Plungers Listed by Syringe Part Number
Replacement
Plunger
Part No.
68
Plunger Code
Pack
Size
Syringe
Part No.
Replacement
Plunger
Part No.
031807
P5F-PE-GT 5 µL
031807
P5F-PE-GT 5 µL
2
001955
031835
2
001957
031835
031810
P10F-GT 10 µL
2
002200
031835
031810
P10F-GT 10 µL
2
002208
031811
P10R-GT 10 µL
2
002250
Plunger Code
Pack
Size
Syringe
Part No.
P500-GT 500 µL
1
007200
P500-GT 500 µL
1
007229
P500-GT 500 µL
1
007230
0318381
P500D-CX 500 µL
1
007232
031835
P500-GT 500 µL
1
007250
007279
031811
P10R-GT 10 µL
2
002313
031835
P500-GT 500 µL
1
031810
P10F-GT 10 µL
2
002335
031835
P500-GT 500 µL
1
007312
031805
P10-GP-GT 10 µL
2
002455
031835
P500-GT 500 µL
1
007630
031811
P10R-GT 10 µL
2
002500
031837
P500-HITACHI 500 µL
1
007660
031803
P10F-C/T-GT
1
002715
0318381
P500D-CX 500 µL
1
007680
031808
P10F-AG-GT 10 µL
2
002812
0318389
P500D-KONTRON-GT
1
007684
031809
P10R-AG-GT 10 µL
2
002817
0318928
P500F-CTC-GT
1
007700
031809
P10R-AG-GT 10 µL
2
002818
0318928
P500F-CTC-GT
1
007720
031808
P10F-AG-GT 10 µL
2
002826
0318381
P500D-CX 500 µL
1
007995
031809
P10R-AG-GT 10 µL
2
002829
031842
P1M-GT 1 mL
1
008020
031798
P10R-S-GT
2
002902
0318441
P1MD-C-GT 1 mL
1
008025
031218
10A-VP 10 µL
1
002923
031842
P1M-GT 1 mL
1
008100
031218
10A-VP 10 µL
1
002924
0318441
P1MD-C-GT 1 mL
1
008102
031218
10A-VP 10 µL
1
002926
031842
P1M-GT 1 mL
1
008110
0318121
P10R-C/T-GT
1
002965
0318444
P1MD-CTC-GT 1 mL
1
008120
0318120
P10F-C/T-GT
1
002977
0318441
P1MD-C-GT
1
008130
0318121
P10R-C/T-GT 10 µL
2
002985
0318441
P1MD-C-GT
1
008135
0318120
P10F-C/T-GT 10 µL
2
002987
031842
P1M-GT 1 mL
1
008160
0318120
P10F-C/T-GT 10 µL
2
002991
031844
P1M-THERMOSEP
1
008180
031815
P25-GT 25 µL
1
003200
0318448
P1MD-SPARK-GT 1 mL
1
008183
031815
P25-GT 25 µL
1
003250
0318449
P1MD-KONTRON-GT
1
008184
031815
P25-GT 25 µL
1
003312
0318441
P1MD-C-GT 1 mL
1
008185
031818
P25-AG-GT 25 µL
1
003668
031842
P1M-GT 1 mL
1
008195
0318922
P25F-CTC-GT
1
003700
031842
P1M-GT 1 mL
1
008199
0318922
P25F-CTC-GT
1
003715
031852
P2.5MD-GT 2.5 mL
1
008420
031816
P25R-C/T-GT 25 µL
1
003985
031852
P2.5MD-GT 2.5 mL
1
008425
031817
P25F-C/T-GT 25 µL
1
003987
031852
P2.5MD-GT 2.5 mL
1
008500
031816
P25R-C/T-GT
1
003989
031852
P2.5MD-GT 2.5 mL
1
008502
For more syringe tips view our video at sge.com/support/videos
Plunger Code
Plunger
Part No.
Pack
Size
Syringe
Part No.
Replacement
Plunger
Part No.
Plunger Code
Pack
Size
Syringe
Part No.
008505
031816
P25R-C/T-GT 25 μL
1
003988
031852
P2.5MD-GT 2.5 mL
1
031819
P25-WISP-GT 25 μL
1
003990
031852
P2.5MD-GT 2.5 mL
1
008510
0318191
P25D-CX 25 μL
1
003995
031852
P2.5MD-GT 2.5 mL
1
008560
031820
P50-GT 50 μL
1
004200
0318549
P2.5MD-KONTRON-GT
1
008584
031820
P50-GT 50 μL
1
004229
0318454
P2.5MD-CTC-GT
1
008620
008630
031820
P50-GT 50 μL
1
004230
0318451
P2.5MDF-GT
1
0318221
P50D-CX 50 μL
1
004232
0318451
P2.5MDF-GT
1
008635
031820
P50-GT 50 μL
1
004250
031853
P2.5M-THERMO 2.5 mL
1
008660
031820
P50-GT 50 μL
1
004279
031854
P2.5MD-C/SHIM(TOC)
1
008687
031820
P50-GT 50 μL
1
004312
031856
P5MD-GT 5 mL
1
008700
031142
P50F-AG-GT
1
004668
031856
P5MD-GT 5 mL
1
008760
031820
P50-GT 50 μL
1
004250
0318562
P5MDF-GT 5 mL
1
008762
031820
P50-GT 50 μL
1
004279
031856
P5MD-GT 5 mL
1
008770
031820
P50-GT 50 μL
1
004312
031856
P5MD-GT 5 mL
1
008775
031142
P50F-AG-GT
1
004668
031856
P5MD-GT 5 mL
1
008780
008787
031821
P50F-C/T-GT 50 μL
1
004810
0318562
P5MDF-GT 5 mL
1
0318221
P50D-CX 50 μL
1
004995
0318562
P5MDF-GT 5 mL
1
008792
031825
P100-GT 100 μL
1
005200
031856
P5MD-GT 5 mL
1
008820
031825
P100-GT 100 μL
1
005229
031862
P10MD-GT 10 mL
1
008900
031825
P100-GT 100 μL
1
005230
031862
P10MD-GT 10 mL
1
008960
0318271
P100D-CX 100 μL
1
005232
031864
P10MDF-LL 10 mL
1
008962
031825
P100-GT 100 μL
1
005236
031862
P10MD-GT 10 mL
1
008970
031825
P100-GT 100 μL
1
005250
031862
P10MD-GT 10 mL
1
008975
031825
P100-GT 100 μL
1
005279
031864
P10MDF-LL 10 mL
1
008987
031826
P100R-C/T-GT
1
005291
031864
P10MDF-LL 10 mL
1
008992
0318263
P100R-AGILENT MEPS™
GT
1
005292
031870
P25MD-GT 25 mL
1
009462
009463
0318274
P100R-SHIM-MEPS-GT
1
005293
031874
P25MDF-GT 25 mL
1
031825
P100-GT 100 μL
1
005312
031870
P25MD-GT 25 mL
1
009472
031826
P100R-C/T-GT 100 μL
1
005330
0312170
50MAX-P 50 mL
1
009660
0318261
P100F-C/T-GT 100 μL
1
005331
0312170
50MAX-P 50 mL
1
009670
031826
P100R-C/T-GT 100 μL
1
005333
0312176
100MAX-P 100 mL
1
009760
0318261
P100F-C/T-GT 100 μL
1
005335
0312176
100MAX-P 100 mL
1
009770
031826
P100R-C/T-GT
1
005337
0312170
50MAX-P 50 mL
1
009660
031823
P100-AG-GT 100 μL
1
005668
0312170
50MAX-P 50 mL
1
009670
0318261
P100F-C/T-GT 100 μL
1
005700
0312176
100MAX-P 100 mL
1
009760
0318261
P100F-C/T-GT
1
005715
0312176
100MAX-P 100 mL
1
009770
0318261
P100F-C/T-GT 100 μL
1
005720
2910380
P5-EVOL
1
2910020
031824
P100-VA8X 100 μL
1
005921
2910380
P5-EVOL
1
2910021
0318271
P100D-CX 100 μL
1
005990
2910382
P-50-EVol ®
1
2910022
031830
P250-GT 250 μL
1
006200
2910382
P-50-EVol®
1
2910023
031830
P250-GT 250 μL
1
006229
2910384
P-500-EVOL
1
2910024
031830
P250-GT 250 μL
1
006230
2910384
P-500-EVOL
1
2910025
031833
P250-THERMO 250 μL
1
006232
2910384
P-500-EVOL
1
2910026
031830
P250-GT 250 μL
1
006250
2910382
P-50-EVOL
1
2910027
031831
P250R-C/T-GT
1
006291
2930380
P25-XCHANGE®
1
2928310
0318301
P250R-CTC-GT
1
006292
2930380
P25-XCHANGE®
1
2928330
0318303
P250R-AGILENT-MEPS-GT
1
006293
2930480
P50-XCHANGE®
1
2928410
0318305
P250R-SHIM-MEPS-GT
1
006294
2930480
P50-XCHANGE
1
2928430
031830
P250-GT 250 μL
1
006279
2930580
P100-XCHANGE
1
2928510
031830
P250-GT 250 μL
1
006312
2930580
P100-XCHANGE
1
2928530
031831
P250R-C/T-GT 250 μL
1
006330
2930680
P250-XCHANGE
1
2928610
031833
P250-THERMO 250 μL
1
006660
2930680
P250-XCHANGE
1
2928630
031832
P250-SHIM (TOC)
1
006680
2930780
P500-XCHANGE
1
2928710
031828
P250-S-GT 250 μL
1
006682
2930780
P500-XCHANGE
1
2928730
0318348
P250D-SPARK 250 μL
1
006683
2930880
P1M-XCHANGE
1
2928820
0318349
P250D-KONTRON-GT
1
006684
2930880
P1M-XCHANGE
1
2928830
031834
P250-WISP-GT 250 μL
1
006690
2930980
P2.5M-XCHANGE®
1
2928920
0318926
P250F-CTC-GT
1
006700
2930985
P5M-XCHANGE
1
2928922
0318926
P250F-CTC-GT
1
006720
2930980
P2.5M-XCHANGE
1
2928930
031833
P250-THERMO 250 μL
1
006995
2930985
P5M-XCHANGE®
1
2928932
Syringes | Replacement Guide
Syringes and
Accessories
69
Syringes | Cross Reference Guide
Hamilton
SGE Replacements for Hamilton Syringes.
Syringes and
Accessories
70
Hamilton
Product Code
1701 N
1702WISP
1725WISP
1701RN(26s/51/2)
1701RNR - Rheodyne
175ASN(23s/1.71"/HP)
175ASN(23s-26s/1.71"/HP)
1701ASN(23s-26s/1.71"/HP)
1701ASN(23s/1.71"/HP)
175ASRN(23s-26s/1.71"/HP)
1701ASRN(23s/1.71 "/HP)
1701ASRN(26s/1.71"/HP)
1701ASRN(23S-26S/1.71"/HP)
175ASN(23s/1.71"/HP)pk/6
175ASN(23s-26s/1.71"/HP)pk/6
1701ASN(23s/1.71"/HP)pk/6
1701ASN(23s-26s/1.71 "/HP)pk/6
1701ASRN(23s/1.71"/HP)
1702N(22s/51/2)
1702RN(22s/51/2
1702CX
1702RNR - Rheodyne
701N(26s/51/2)
701RN(26s/51/2)
701RN-HP(26s/2"/2)
701SN(26s/2.75"/2)
701ASRN(23s/1.71"/HP)
701ASRN(26s/1.71"/HP)
701ASRN(23s-26s/1.71"/HP)
901N
701NR - Rheodyne
701N 6p/k
901RN
701ASN(23s/1.71"/HP)
701ASN(26s/1.71"/HP)
701ASN(26s/1.7l"/HP) Pkt6
701ASN(23s/1.71"/HP) Pkt6
701ASN(23s-26s/1.71"/HP)
701ASN(23s-26s/1.71"/HP)
702N(22s/51/2)
702SN(22/51/3)
702NR - Rheodyne
705N(22s/51/2)
705LT
705RN(22s/51/2)
705CA (50 µL, 2.5")
705NR(22s/51/3)
710N
710LT
710RN
710NR(22s/51/3)
725N(22s/51/2)
725LT
725RN(22s/51/2)
725SNR - Rheodyne
750N
750LT
750RN(22s/51/2)
7001KH(25s/2.75"/3)
Hamilton
Part No.
80000
80020
80024
80030
80065
80074
80076
80079
80080
80086
80087
80088
80089
80090
80092
80094
80096
80176
80200
80230
80262
80265
80300
80330
80338
80350
80357
80358
80359
80360
80365
80366
80370
80387
80388
80389
80390
80391
80393
80400
80419
80465
80500
80501
80530
80551
80565
80600
80601
80630
80665
80700
80701
80730
80765
80800
80801
80830
80100
SGE
Product Code
10F-GT
25D-WISP
250D-WISP
10R-GT
10R-GT-LC
10F-AG-GT-0.63
5F-AG-0.63/0.47
10F-AG-GT-0.63/0.47
10F-AG-GT-0.63
5R-AG-0.63/0.47
10R-AG-GT-0.63
10R-AG-GT-0.47
10R-AG-GT-0.63/0.47
SK-5F-AG-0.63
SK-5F-AG-0.63/0.47
SK-10F-AG-GT-0.63
SK-10F-AG-GT-0.63/0.47
1BR-AG-0.63
25F-GT
25R-GT
25D-CX-GT
25R-GT-LC
10F
10R
10R
10F-7
10R-AG-0.63
10R-AG-0.47
10R-AG-0.63/0.47
10F-GP
10F-LC
SK-10F
10R-GP
10F-AG-0.63
10F-AG-0.47
SK-10F-AG-0.47
SK-10F-AG-0.63
SK-10F-AG-0.63/0.47
10F-AG-0.63/0.47
25F
25F-LC
25F-LC
50F
50F-LT-GT
50R
100F-LT-GT-6.5CA
50F-LC
100F
100F-LT-GT
100R
100F-LC
250F
250F-LT-GT
250R
250F-LC
500F
500F-LT-GT
500R
1BR-7/0.47
SGE
Part No.
002200
003990
006690
002250
002313
002812
001821
002826
002812
001825
002818
002817
002829
001814
001822
002813
002827
000610
003200
003250
003995
003312
002000
002050
002050
002003
002815
002805
002825
002400
002301
002030
002450
002810
002800
002804
002814
002822
002821
003000
003300
003300
004000
004229
004050
005236
004300
005000
005229
005050
005300
006000
006229
006050
006300
007000
007229
007050
000570
This selection guide can be viewed as an electronic book at sge.com/selectionguide
Hamilton
Product Code
750SNR - Rheodyne
1705N(22s/51/2)
1705LT
1705TLL
1705RN
1705SL
1705CX
1705RNR - Rheodyne
1710N
1710LT
1710TLL
1710RN(22s/51/2)
1710SL
1710CX
1710RNR - Rheodyne
1725N(22s/51/2)
1725LT
1725TLL
1725RN
1725SL
1725CX
1725RNR - Rheodyne
1750LT
1750RN
1750SL
1750CX
1750RNR - Rheodyne
1001LT
1001TLL
1001RN(22/51/2)
1001SL
1001C
1002LT
1002TLL
1002RN(22/51/2)
1002SL
1002C
1005TLL
1005RN(22/51/2)
1010W
1010TLL
1010RN(22/51/2)
1010C
1025TLL
801N(26s/51/2)
801RN(26s/51/2)
1801RN(26s/51/2)
1050TLL
1100TLL
7000.5ASRN
7000.5ASRN
S0500 (TLL)
S1000 (TLL)
S2000 (TLL)
1025SL
1050SL
1100SL
701RNFS(0.17/10cm/3)
75N(26s/51/2)
Hamilton
Part No.
80865
80900
80901
80920
80930
80956
80962
80965
81000
81001
81020
81030
81056
81062
81065
81100
81101
81120
81130
81156
81162
81165
81201
81230
81256
81262
81265
81301
81320
81330
81356
81360
81401
81420
81430
81456
81460
81520
81530
81610
81620
81630
81660
82520
84852
84853
84877
85020
86020
86274
86276
86311
86312
86314
86326
86336
86346
87402
87900
SGE
Product Code
500F-LC
50F-GT
50F-LT-GT
50F-LL-GT
50R-GT
50R-V-GT
50D-CX-GT
50R-GT-LC
100F-GT
100F-LT-GT
100F-LL-GT
100R-GT
100R-V-GT
100D-CX-GT
100R-GT-LC
250F-GT
250F-LT-GT
250F-LL-GT
250R-GT
250R-V-GT
250D-CX-GT
250R-GT-LC
500F-LT-GT
500R-GT
500R-V-GT
500D-CX-GT
500R-GT-LC
1 MDF-LT-GT
1 MDF-LL-GT
1 MDR-GT
1MDR-V-GT
1MD-C-GT
2.5MDF-LT-GT
2.5MDF-LL-GT
2.5MDR-GT
2.5MDR-V-GT
2.5MD-C-GT
5MDR-LL-GT
5MDR-GT
10MDF-LL-GT
10MDR-LL-GT
10MDR-GT
10MD-C-GT
25MDF-LL-GT
10F-GP
10R-GP
10R-GP-GT
50MR-LL-GT
100MR-LL-GT
0.5BR-AG-0.47
0.5BR-AG-0.63
500MAR-LL-GT
1000MAR-LL-GT
2000MAR-LL-GT
25MDR-VLLMA-GT
50MR-VLLMA-GT
100MR-VLLMA-GT
10R-0C-100VS
5F
SGE
Part No.
007300
004200
004229
004230
004250
004279
004995
004312
005200
005229
005230
005250
005279
005990
005312
006200
006229
006230
006250
006279
006995
006312
007229
007250
007279
007995
007312
008020
008025
008100
008110
008185
008420
008425
008500
008510
008687
008760
008700
008962
008960
008900
008987
009463
002400
002450
002455
009660
009760
000400
000410
009910
009920
009930
009472*
009670*
009770*
002520
001000
Syringes and
Accessories
If you can not
find an equivalent
syringe listed, contact SGE for a suitable alternative.
* Please note no needle fitted to the syringe.
Syringes | Cross Reference Guide
71
Syringes | Cross Reference Guide
SGE Replacements for Hamilton Syringes continued
Syringes and
Accessories
72
Hamilton
Product Code
95N 5.0ul SYR (26s/2"/2)
95RN
75RN(26s/51/2)
75ASRN(23s/1.71"/HP)
75ASRN(26S/1.71"/HP)
75ASRN(23s-26s/1.71"/HP)
75ASN(23s/1.7"/HP)
75ASN(26s/1.71"/HP)
75ASN(26s/1.71"/HP) Pk/6
75ASN(23s/1.7l"/HP) Pk/6
75ASN(23s-26s/1 .71"/HP)
75ASN(23s-26s/1.71"/HP) Pk6
1750-HITACHI
7105KH (24/2.75"/3)
7105KH (24/2.75"/2)
75ASN/PE-0.63
75ASN/PE-0.47
701N Fisons(0.47/80/AS)
701RSN-AOC14
701 Varian
1702 CTC(26S/51/AS)
701N CTC (26s/2)
701N CTC (22s/3)
1702 CTC(26/AS) slim line
1702NCTC(22S/51/3)
1710 CTC(26S/51/AS)
1710 CTC(22S/51/3)
1725 CTC(26/51/AS)
1725NCTC(22/51/3)
1750CTC (26s/AS)
1001CTC (23/5)
1001CTC (26/5)
1002LTN CTC (22/51/3)
1002CTC (23/5)
1002CTC (26/5)
1005LTN CTC (22/51/3)
75N CTC (26s/AS)
1701 CTC(22S/51/3)
701 N CTC (26s/AS)
1710N CTC (22s/3)
1750N CTC (22/3)
701N CTC (23s/AS)
Hamilton
Part No.
87920
87925
87930
87957
87958
87959
87987
87988
87989
87990
87993
87994
0160310
88000
88011
88035
88040
202066
202640
202880
203043
203072
203073
203074
203075
203076
203077
203078
203079
203080
203082
203141
203083
203084
203181
203085
203189
203194
203205
203235
203349
203361
SGE
Product Code
5F-GP
5R-GP
5R
5R-AG-0.63
5R-AG-0.47
5R-AG-0.63/0.47
5F-AG-0.63
5F-AG-0.47
SK-5F-AG-0.47
SK-5F-AG-0.63
5F-AG-0.63/0.47
SK-5F-AG-0.63/0.47
500C-HITACHI
5BR-7
5BR-7BV
5F-PE-0.63
5F-PE-0.47
10F-C/T-8/0.47C
10R-S-0.63
10R-VA8X-2
25F-CTC-GT-5/0.47C
10F-CTC-5/0.47BV
10F-CTC-LC
25F-CTC-GT-5/0.47C
25F-CTC-GT-LC
100F-CTC-GT-5/0.47C
100F-CTC-GT-LC
250F-CTC-GT-5/0.47C
250F-CTC-GT-LC (0.4)
500F-CTC-GT-5/0.47C
1MF-CTC-GT-HS-5/0.63H
1MF-CTC-GT-HS-5/0.47H
2.5MR-CTC-GT-LC(0.41)
2.5MF-CTC-GT-HS-5/0.63H
2.5MF-CTC-GT-HS-5/0.47H
5MR-CTC-GT-LC(0.41)
5F-C/T-5/0.47C
10F-CTC-GT-LC
10F-CTC-5/0.47C
100F-CTC-GT-LC (0.4)
500F-CTC-GT-LC (0.4)
10F-C/T-5/0.63C
Syringes | Cross Reference Guide
SGE
Part No.
001400
001450
001050
001815
001805
001825
001810
001800
001804
001814
001821
001822
007660
000802
000803
001954
001953
002992
002898
002924
003700
002705
002710
003700
003715
005700
005715
006700
006720
007700
008130
008135
008620
008630
008635
008820
001982
002715
002700
005720
007720
002981
Was this manual useful for you? yes no