FBQ-D_FXSQ-A_ECPEN15-102A
Concealed
ceiling unit
with medium
ESP
FBQ-D, FXSQ-A
Home leave
Optimum comfort guaranteed no matter the
length of ductwork or type of grilles
operation
Powerful mode
Multi tenant (FXSQ)
›› Top efficiency in the market
›› Automatic air flow adjustment function measures the
air volume and static pressure and adjusts it towards
the nominal air flow, whatever the length of duct,
making installation easier and guaranteeing comfort.
Moreover, the ESP can be changed via the wired
remote control to optimize the supply air volume
›› Slimmest unit in class, only 245mm
›› Discretely concealed in the ceiling: only the suction
and discharge grilles are visible
›› Low sound level
›› Medium external static pressure up to 150Pa facilitates
using flexible ducts of varying lengths
›› Reduced energy consumption thanks to specially
developed DC fan motor
›› Flexible installation, as the air suction direction can be
altered from rear to bottom suction
›› Standard built-in drain pump increases flexibility and
installation speed
›› No optional adapter needed for DIII-connection, link
your unit into the wider building management system
FBQ-D
Perfect for light commercial and residential applications
BRC1E52A-B, BRC4C65
FXSQ-A
Fully integrated solutions for medium to large
commercial environments
FBQ35-50D, FXSQ40-50A
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Dimensions
Nom.
Nom.
Cooling
Heating
Unit
FXSQ
kW
kW
kW
kW
mm
mm
mm
kg
Nom.
Nom.
Height
Width
Depth
Weight
Casing
Unit
Colour
Material
Fan-Air flow rate Cooling
High/Nom./Low
50Hz
Heating
High/Nom./Low
Fan-External static pressure - 50Hz High/Nom.
Air filter
Type
Sound power level
Cooling
Nom.
Sound pressure level Cooling
High/Nom./Low
Heating
High/Nom./Low
Refrigerant
Type
Piping connections
Liquid
OD
Gas
OD
Drain
Power supply
Phase/Frequency/Voltage
Current - 50Hz
Maximum fuse amps (MFA)
Control systems
Infrared remote control
Simplified wired remote control for hotel applications
Wired remote control
15A
1.7
1.9
20A
2.2
2.5
0.041
0.038
25A
2.8
3.2
550
23.5
m³/min 8.7/7.5/6.5
m³/min 8.7/7.5/6.5
Pa
9/7.5/6.5
9/7.5/6.5
dBA
dBA 29.5/28/25
dBA 31.5/29/26
54
30/28/25
32/29/26
mm
mm
Hz/V
A
32A
3.6
4.0
0.045
0.042
40A
4.5
5.0
0.092
0.089
50A
5.6
6.3
0.095
0.092
245
63A
7.1
8.0
0.095
0.092
80A
9.0
10.0
0.121
0.118
100A
11.2
12.5
0.157
0.154
125A
14.0
16.0
0.214
0.211
700
Control systems
FBQ
Colour
Unit
HeightxWidthxDepth
Cooling
Cooling
High/Nom./Low
Heating
High/Nom./Low
Infrared remote control
Wired remote control
140A
16.0
18.0
0.243
0.240
1,000
1,400
1,550
800
24
28.5
29
35.5
36.5
46
47
51
Not painted (galvanised)
Galvanised steel plate
9.5/8/7.0 15/12.5/11 15.2/12.5/11 21.0/18/15 23/19.5/16 32/27/23 36/31.5/26 39/34/28
9.5/8/7 15/12.5/11 15.2/12.5/11 21/18/15 23/19.5/16.0 32/27/23 36/31.5/26 39/34/28
150/30
150/40
150/50
Resin net with mold resistance
55
60
59
61
64
31/29/26
35/32/29
33/30/27 35/32/29 36/34/31 39/36/33 41.5/38/34
33/30/27
37/34/29
35/32/28 37/34/30 37/34/31 40/37/33 42/38.5/34
R-410A
6.35
9.52
12.7
15.9
VP20 (I.D. 20/O.D. 26)
1~/50/60/220-240/220
16
BRC4C65
BRC2E52C (heat recovery type) / BRC3E52C (heat pump type)
BRC1D52 / BRC1E52A/B
The sound power level is an absolute value indicating the power which a sound source generates.
Indoor unit
Casing
Dimensions
Sound power level
Sound pressure level
Combination with Seasonal Smart ensures high quality, optimal comfort, flexible installation
and highest efficiency values
RXS35L3
Efficiency data
Cooling capacity
Heating capacity
Power input
Seasonal efficiency
(according to
EN14825)
mm
dBA
dBA
dBA
50D
Not painted (galvanised)
60D
245x700x800
60
35/32/29
37/34/29
245x1,000x800
56
30/28/25
31/28/25
Nom.
Nom.
Cooling
Heating
Cooling
Heating (Average
climate)
Nominal efficiency
EER
COP
Annual energy consumption
Energy label
Cooling/Heating
Outdoor unit
Dimensions
Sound power level
Sound pressure level
Seasonal efficiency
(according to
EN14825)
Nom.
Nom.
Cooling
Heating
Cooling
Heating (Average
climate)
Nominal efficiency
Operation range
Power supply
FBQ + RXS
kW
kW
kW
kW
35D + 35L3
3.4
4.00
0.85
1.00
50D + 50L
5.0
5.50
1.42
1.44
Contains fluorinated greenhouse gases
kWh
6.00
4.31
1,949
3.60
4.01
944
A/A
140D +
140L9V1
13.4
15.50
4.38
4.56
3.06
3.40
2,190
-
7.60
4.15
2,564
3.35
3.67
1,418
4.01
2,653
3.23
3.63
1,858
A/A
100D +
100L8Y1
9.5
10.80
2.84
2.94
A+
9.50
5.61
593
125D +
125L8Y1
12.0
13.50
3.72
3.72
A
12.00
5.47
768
A/A
140D +
140LY1
13.4
15.50
4.38
4.56
3.06
3.40
2,190
-
100L8Y1
125L8Y1
990x940x320
70
54
57
58
140LY1
1,430x940x320
69
53
54
A+
7.60
4.15
2,564
3.35
3.67
1,418
4.01
2,653
3.23
3.63
1,858
RZQG
mm
dBA
dBA
dBA
dBA
°CDB
°CWB
kg/TCO₂eq
Hz/V
71L9V1
990x940x320
64
48
50
43
-15~50
-20~15.5
100L9V1
125L9V1
990x940x320
70
53
54
57
58
2.9/6.1
2.9/6.1
1~/50/220-240
140L9V1
1,430x940x320
69
53
54
49
-15~46
-15~15.5
R-410A/2,087.5
4.0/8.4
2.9/6.1
3N~/50/380-415
4.0/8.4
Combination with Seasonal Classic ensures good value for money for all types of commercial applications
60D + 60L
5.7
7.00
1.65
1.89
A+
5.70
5.86
340
A++
kW
kWh
kW
kWh
kWh
RXS
Unit
HeightxWidthxDepth
mm
Cooling
dBA
Heating
dBA
High/Nom./Low/Silent operation
dBA
Sound pressure level Cooling
High/Nom./Low/Silent operation
dBA
Heating
Night quiet mode Level 1
dBA
Operation range
Cooling
Ambient
Min.~Max.
°CDB
Heating
Ambient
Min.~Max.
°CWB
Refrigerant
Type/GWP
kg/TCO₂eq
Charge
Power supply
Phase/Frequency/Voltage
Hz/V
2
kW
125D +
125L9V1
12.0
13.50
3.72
3.72
A
12.00
5.47
768
Contains fluorinated greenhouse gases
3.40
6.17
193
2.90
4.07
998
3.99
4.02
426
5.00
6.21
282
A+
4.40
4.06
1,517
3.52
3.83
710
A/A
4.60
4.01
1,606
3.45
3.71
826
Efficiency data
Cooling capacity
Heating capacity
Power input
Seasonal efficiency
(according to
EN14825)
35L3
550x765x285
61
61
48/-/-/44
48/-/-/45
1.2/2.5
1~/50/220-240
50L
60L
735x825x300
62
62
48/-/44/48/-/45/-10~46
-15~18
R-410A/2,087.5
1.7/3.5
49/-/46/49/-/46/-
Nominal efficiency
Nom.
Nom.
Cooling
Heating
Cooling
Nom.
Nom.
Energy label
Pdesign
SEER
Annual energy consumption
Energy label
Pdesign
SCOP
Annual energy consumption
EER
COP
Annual energy consumption
Energy label
Cooling/Heating
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
71D +
71L3V1
6.8
7.50
1.89
1.87
A++
6.80
6.16
386
A+
6.00
4.31
1,949
3.60
4.01
944
100D +
100L9V1
9.5
10.80
2.49
2.45
A+
9.50
5.87
566
A++
11.30
4.78
3,310
3.81
4.41
1,247
A/A
125D +
125L9V1
12.0
13.50
3.63
3.46
A++
12.00
6.11
687
A+
12.70
4.28
4,154
3.31
3.90
1,813
140D +
140L9V1
13.4
15.50
4.00
4.31
3.35
3.60
2,000
-
100D +
100L8Y1
9.5
10.80
2.49
2.45
A+
9.50
5.87
566
A++
11.30
4.78
3,310
3.81
4.41
1,247
140L9V1
100L8Y1
69
52
66
50
52
125D +
125L8Y1
12.0
13.50
3.63
3.46
A++
12.00
6.11
687
A+
12.70
4.28
4,154
3.31
3.90
1,813
A/A
140D +
140LY1
13.4
15.50
4.00
4.31
3.35
3.60
2,000
-
EER/COP according to Eurovent 2012, for use outside EU only | Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Outdoor unit
Dimensions
Sound power level
Sound pressure level
Operation range
Refrigerant
1.5/3.1
1~/50/220-230-240
FBQ + RZQSG
Heating (Average
climate)
EER/COP according to Eurovent 2012, for use outside EU only | Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Outdoor unit
Dimensions
Sound power level
kWh
100D +
100L9V1
9.5
10.80
2.84
2.94
A+
9.50
5.61
593
A+
BRC4C65
BRC1E52A/B / BRC1D528
Nom.
Nom.
Energy label
Pdesign
SEER
Annual energy consumption
Energy label
Pdesign
SCOP
Annual energy consumption
EER
COP
Annual energy consumption
Energy label
Cooling/Heating
kW
kWh
Unit
HeightxWidthxDepth
Cooling
Cooling
Nom.
Heating
Nom.
Night quiet mode Level 1
Cooling
Ambient
Min.~Max.
Heating
Ambient
Min.~Max.
Type/GWP
Charge
Phase/Frequency/Voltage
Combination with split outdoor units is ideal for smaller applications such as retail or residential applications
Efficiency data
Cooling capacity
Heating capacity
Power input
Nom.
Nom.
Energy label
Pdesign
SEER
Annual energy consumption
Energy label
Pdesign
SCOP
Annual energy consumption
kW
kW
kW
kW
71D +
71L9V1
6.8
7.50
1.89
1.87
A++
6.80
6.16
386
EER/COP according to Eurovent 2012, for use outside EU only | Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Refrigerant
35D
FBQ + RZQG
Power supply
Unit
HeightxWidthxDepth
Cooling
Cooling
Nom.
Heating
Nom.
Night quiet mode Level 1
Cooling
Ambient
Min.~Max.
Heating
Ambient
Min.~Max.
Type/GWP
Charge/
Phase/Frequency/Voltage
RZQSG
mm
dBA
dBA
dBA
dBA
°CDB
°CWB
kg/TCO₂eq
Hz/V
71L3V1
770x900x320
65
49
51
-15~46
-15~15.5
2.75/5.7
100L9V1
66
50
52
125L9V1
1,430x940x320
67
51
53
45
125L8Y1
1,430x940x320
67
51
53
45
140LY1
69
52
-15~50
-20~15.5
R-410A/2,087.5
4.0/8.4
1~/50/220-240
4.0/8.4
3N~/50/380-415
Contains fluorinated greenhouse gases
3
Daikin Europe N.V. participates in the Eurovent Certification
programme for Liquid Chilling Packages (LCP), Air handling
units (AHU), Fan coil units (FCU) and variable refrigerant flow
systems (VRF) Check ongoing validity of certificate online:
www.eurovent-certification.com or using: www.certiflash.com
FSC
ECPEN15 - 102A
xxx · 04/15
The present publication is drawn up by way of information only and does not constitute an offer binding upon
Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its
content and the products and services presented therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from
or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.
The present publication supersedes ECPEN15-102. Printed on non-chlorinated paper.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement