advertisement
▼
Scroll to page 2
of 4
INSTALLATION I OWNER'S MANUAL for Alaska Direct Vent System (ADy) For Alaska Stoker Models: Channing III RY, KC III RV, Liberty RV Rear Vented Models Note: Read all instructions thoroughly before attempting to install this vent system. CAUTIONII "C The :Alaska·Direct Vent System is designed for use only with the Alaska Stoker Stove to exhaust byproducts ofcombustion through a combustible wall ro the exterior of a building. Do not use this. vent system with any ~ appliances ~jt may cause injury or a, house fire. . i ~·~~roisi~e fOr lI,I1extended period of time with either the view door [' 'or aSh doOropetb .~ wiIl~VIIte !he safety switch and shut the st~ down, other ~~W~}'~~~ 'co • • • ~.''''''._-'' c >.,>, . .•. .'. . Tested 4/01 TO UL 1482 Conam Inspection Inc. 2 Millbury Street Auburn, M....chusetts 01501 STL-002 Alaska Company, Inc. 3162 Columbia Blvd., Bloomsburg PA 17815 4106 \ PLANNING THE VENT SYSTEM A. The exit termination of a mechanical draft system must not be less than 7' above grade when located D. The bottom of the vent terminal must be located at least 12" above finished grade. adjacent to a public walkway. E. A venting system must terminate at least 3' above any forced. air inlet located within 10'. B. The vent termination of a Direct Vent or sealed combustion appliance with an input of 50,000 BTU's per hour or less must be located at least 9" from any opening through which vented gases could enter the building. With an input ovec 50,000 BTU's per hour, aI' termination clearance is required. Another term for direct vent is sealed combustion. F. The vent termination point must nor be installed closer than 3' from an inside corner of an L-shaped structure. G. The venter termination should not be mounted directly above or within 3' horizontally from an oil tank vent or gas meter. C. The venting system of a Direct Vent must exhaust at least 4' below any door or window or gravity air inlet into the building. ~ =:::::::::::-J D =-------- -"'F § - -- -~ 2 C E - I b -- ~- INSTALLING THE ALASKA DIRECT VENT SYSTEM Caution: Before installing your stove and vent system, ADVPARTS check all clearances and local codes. Take time to I - ADV Vent Housing With Motor I - Side Wall Vent Hood familiarize yourself with the stove and components. See stove manual for stove specifications. 1 - ADV Manual I - 4" x 24" piece pipe 1 - Fume Switch 1 - Cleaning Brush Step 2: Place the 4"x24" pipe into the 4" hole of ADV Vent Housing. Position stove in desired location with Step 4: Cord Connection A) Plug 5t male cord from feed system into female cord ftom fume switch. B) Plug male cord ftom fume switch into wall outlet. C) Plug male cord from ADV into triple plug on feed system of stove. D) Plug male cord from blower rheostat into remaining female end of triple plug (see stove manual for information pipe against wall where hole is on rheostats). Step 1: Assemble stove according to stove manual. Mount ADV Vent Housing on stove body as follows: Locate ADV Vent Housing, slide 6" pipe of vent housing over 6" pipe on bottom back of stove, then tighten the 2 bolts firmly. to be cut for exhaust. Pur a mark on wall around pipe, move stove. Find center of mark on wall cut an 8"x8" hole through wall centered with mark. (Note: hole can be round) Note: If feed system does not operate, first check reset on fume switch, (wcated on back center ofswitch), using eraser on pencil, insert into hole and reset switch, (switch must be cool to reset). Step 3: Locate side wall vent hood and components. Insert vent hood through wall from outside, centering 6" tube in hole. Attach with four screws and then seal vent hood against house with caulking. Note: 6" outer tube of vent hood must extend through finished wall. To extend tube, cut a 6" piece of stove pipe to length, insert and attach with screws. Slide a trim ring over 6" tube of vent hood, attach to finished wall with screws. Position stove and cut 4" tube to length, attach to vent hood and stove with screws. Seal all seams with high-temperature silicone (Be sure to alww at least 2" ofspace between back ofhopper and flammable surfocef). Silicone around outside edge of crimp on 4" tube and attach with three screws to vent hood. CAUTION: Always make sure vent system is plugged in and operates before starting fire! Important! Draft Adjustment Make sure vent system is operating. Light stove according to stove manual. Remove Allen screw located at top side of stove. Insert draft meter into hole. Draft reading should read .03 to .04 in/w.e. (See your dealer for infonnation on draft meters). CAUTION! Always check draft <ea<\ing. The length and configuration of vent pipe will vary draft reading. CAUTION: Make sure all joints are sealed with high-temperature silicone, and attached with screws!! 3 MONTHLY MAlNTENAi"lCE hood on outside of house, remove rout sercllis holditlg vent hood cover and remove. Clean pipe, replace cover. Vent system should be cleaned on a monthly basis. To dean system: 1) Unplug feed system and allow stove to cool. Use a well filtered vacuum cleaner (Shop Vac), alId clean inside of stove body, also insert Vaalurn hose through hole in bottom back of stove and dean ADV box, Thoroughly clean fume switch tube with brush or vacuum. Replace ash pan and dose ash door. 3) Test your fume switchl This should be done twO times during the burning season. Using a butane torch. hold me flame in the tube of the fume switch, (imide back ofstove). "'lith feed system running. Hold until the fume switch trips shurting down the fi:ed system. If feed system does not shut off, DO NOT OPERATE STOVE! Comact your local dealer for replacement switco. 2} Unplug vent system and remove the 6-114" screws that hold motor in place, and remove motor from ADV Housing. Clean fan, housing and vent pipe with vacuum. Replace motor and screws. Locate vent END OF YEAR MAINTENANCE 2) Remove motor" dean fun and ADY box. aean stove 1) Remove stove pipe from vern housing and dean thoroughly. (Make S1.lte when pipe- is assembled that ALL seams are ,.aled with high temperature silicone before operating stove again.) according to manual ADV Warranty; Sec storf' mal/If(d W(l1't""~l' / e/c{ trica/ pdJ'/S . TROUBLESHOOTING Before you callyour deakr, check the following Feed system docs not run. Vent system does not run, Fume ,>witch unplugged or fume switch needs to be reser. Oean vent system moroughJy. Make sure doors are shut and sealed. Vent system not plugged into power Fume switch tripped. Plug ADV cord into 110V outlet. Unplug unit remove junction box cover check for loose wires. Replace Motor. Reset Switch Blocked exhausr wheel. Doors not shut on stove body. Vent system improperly sealed. Un.pl,.g Unlt and clean entire vent system. Make sure vent hood is sealed to house, Seal all exhaust system seams with high source. Loose wires in junction box. Sulfur odor or CO alarm sounds. temperature silicone, CI"", doors. Replace gasketing, --_ 4 ......
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project