INSTALLATION I OWNER'S MANUAL
for
Alaska Direct Vent System (ADy)
For Alaska Stoker Models:
Channing III RY, KC III RV, Liberty RV
Rear Vented Models
Note: Read all instructions thoroughly before attempting to install this vent system.
CAUTIONII
"C
The :Alaska·Direct Vent System is designed for use only with the Alaska Stoker Stove
to exhaust byproducts ofcombustion through a combustible wall ro the exterior of a
building. Do not use this. vent system with any ~ appliances ~jt may cause
injury or a, house fire.
.
i
~·~~roisi~e fOr lI,I1extended period of time with either the view door
[' 'or aSh doOropetb .~ wiIl~VIIte !he safety switch and shut the st~ down, other
~~W~}'~~~ 'co
•
• • ~.''''''._-''
c
>.,>,
. .•. .'. .
Tested 4/01 TO UL 1482
Conam Inspection Inc.
2 Millbury Street
Auburn, M....chusetts 01501 STL-002
Alaska Company, Inc.
3162 Columbia Blvd.,
Bloomsburg PA 17815
4106
\
PLANNING THE VENT SYSTEM
A. The exit termination of a mechanical draft system
must not be less than 7' above grade when located
D. The bottom of the vent terminal must be located at
least 12" above finished grade.
adjacent to a public walkway.
E. A venting system must terminate at least 3' above any
forced. air inlet located within 10'.
B. The vent termination of a Direct Vent or sealed
combustion appliance with an input of 50,000
BTU's per hour or less must be located at least 9"
from any opening through which vented gases could
enter the building. With an input ovec 50,000 BTU's
per hour, aI' termination clearance is required.
Another term for direct vent is sealed combustion.
F. The vent termination point must nor be installed
closer than 3' from an inside corner of an L-shaped
structure.
G. The venter termination should not be mounted
directly above or within 3' horizontally from an oil
tank vent or gas meter.
C. The venting system of a Direct Vent must exhaust at
least 4' below any door or window or gravity air inlet
into the building.
~
=:::::::::::-J D
=--------
-"'F
§
-
--
-~
2
C
E
- I b
--
~-
INSTALLING THE ALASKA DIRECT VENT SYSTEM
Caution: Before installing your stove and vent system,
ADVPARTS
check all clearances and local codes. Take time to
I - ADV Vent Housing With Motor
I - Side Wall Vent Hood
familiarize yourself with the stove and components. See
stove manual for stove specifications.
1 - ADV Manual
I - 4" x 24" piece pipe
1 - Fume Switch
1 - Cleaning Brush
Step 2: Place the 4"x24" pipe into the 4" hole of ADV
Vent Housing. Position stove in desired location with
Step 4: Cord Connection
A) Plug 5t male cord from feed system into female cord
ftom fume switch.
B) Plug male cord ftom fume switch into wall outlet.
C) Plug male cord from ADV into triple plug on feed
system of stove.
D) Plug male cord from blower rheostat into remaining
female end of triple plug (see stove manual for information
pipe against wall where hole is
on rheostats).
Step 1: Assemble stove according to stove manual.
Mount ADV Vent Housing on stove body as follows:
Locate ADV Vent Housing, slide 6" pipe of vent housing
over 6" pipe on bottom back of stove, then tighten the 2
bolts firmly.
to
be cut for exhaust. Pur
a mark on wall around pipe, move stove. Find center of
mark on wall cut an 8"x8" hole through wall centered
with mark. (Note: hole can be round)
Note: If feed system does not operate, first check reset on
fume switch, (wcated on back center ofswitch), using
eraser on pencil, insert into hole and reset switch, (switch
must be cool to reset).
Step 3: Locate side wall vent hood and components.
Insert vent hood through wall from outside, centering 6"
tube in hole. Attach with four screws and then seal vent
hood against house with caulking. Note: 6" outer tube of
vent hood must extend through finished wall. To extend
tube, cut a 6" piece of stove pipe to length, insert and
attach with screws. Slide a trim ring over 6" tube of vent
hood, attach to finished wall with screws. Position stove
and cut 4" tube to length, attach to vent hood and stove
with screws. Seal all seams with high-temperature silicone
(Be sure to alww at least 2" ofspace between back ofhopper
and flammable surfocef). Silicone around outside edge of
crimp on 4" tube and attach with three screws to vent
hood.
CAUTION: Always make sure vent system is plugged
in and operates before starting fire!
Important! Draft Adjustment
Make sure vent system is operating. Light stove according
to stove manual. Remove Allen screw located at top side
of stove. Insert draft meter into hole. Draft reading
should read .03 to .04 in/w.e. (See your dealer for
infonnation on draft meters).
CAUTION! Always check draft <ea<\ing. The length
and configuration of vent pipe will vary draft
reading.
CAUTION: Make sure all joints are sealed
with high-temperature silicone, and attached
with screws!!
3
MONTHLY MAlNTENAi"lCE
hood on outside of house, remove rout sercllis
holditlg vent hood cover and remove. Clean pipe,
replace cover.
Vent system should be cleaned on a monthly basis. To
dean system:
1) Unplug feed system and allow stove to cool. Use a
well filtered vacuum cleaner (Shop Vac), alId clean
inside of stove body, also insert Vaalurn hose through
hole in bottom back of stove and dean ADV box,
Thoroughly clean fume switch tube with brush or
vacuum. Replace ash pan and dose ash door.
3) Test your fume switchl This should be done twO
times during the burning season. Using a butane
torch. hold me flame in the tube of the fume switch,
(imide back ofstove). "'lith feed system running. Hold
until the fume switch trips shurting down the fi:ed
system. If feed system does not shut off, DO NOT
OPERATE STOVE! Comact your local dealer for
replacement switco.
2} Unplug vent system and remove the 6-114" screws
that hold motor in place, and remove motor from
ADV Housing. Clean fan, housing and vent pipe
with vacuum. Replace motor and screws. Locate vent
END OF YEAR MAINTENANCE
2) Remove motor" dean fun and ADY box. aean stove
1) Remove stove pipe from vern housing and dean
thoroughly. (Make S1.lte when pipe- is assembled
that ALL seams are ,.aled with high temperature
silicone before operating stove again.)
according to manual
ADV Warranty; Sec storf' mal/If(d W(l1't""~l' / e/c{ trica/ pdJ'/S
.
TROUBLESHOOTING
Before you callyour deakr, check the following
Feed system docs not run.
Vent system does not run,
Fume ,>witch unplugged or fume
switch needs to be reser.
Oean vent system moroughJy.
Make sure doors are shut and sealed.
Vent system not plugged into power
Fume switch tripped.
Plug ADV cord into 110V outlet.
Unplug unit remove junction box cover check
for loose wires.
Replace Motor.
Reset Switch
Blocked exhausr wheel.
Doors not shut on stove body.
Vent system improperly sealed.
Un.pl,.g Unlt and clean entire vent system.
Make sure vent hood is sealed to house,
Seal all exhaust system seams with high
source. Loose wires in junction box.
Sulfur odor or CO alarm
sounds.
temperature silicone,
CI"", doors.
Replace gasketing,
--_