Rosemount Micro Motion 1600 Owner's Manual
PDF
Документ
Реклама
Реклама
Configuration and Use Manual MS-00809-0200-1600, Rev AA May 2024 Micro Motion™ 1600 Transmitters with Configurable Inputs and Outputs Configuration and Use Manual Safety messages Safety messages are provided throughout this manual to protect personnel and equipment. Read each safety message carefully before proceeding to the next step. Safety and approval information This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EU Declaration of Conformity for directives that apply to this product. The following are available: the EU Declaration of Conformity, with all applicable European directives, and the complete ATEX installation drawings and instructions. In addition, the IECEx installation instructions for installations outside of the European Union and the CSA installation instructions for installations in North America are available at Emerson.com or through your local Micro Motion support center. Information affixed to equipment that complies with the Pressure Equipment Directive, can be found at Emerson.com. For hazardous installations in Europe, refer to standard EN 60079-14 if national standards do not apply. Other information Troubleshooting information can be found in the appropriate Configuration and Use Manual. Product Data Sheets and Manuals are available from the Micro Motion website at Emerson.com. Return policy Follow Emerson procedures when returning equipment. These procedures ensure legal compliance with government transportation agencies and help provide a safe working environment for Emerson employees. If you fail to follow Emerson procedures, then Emerson will not accept your returned equipment. Return procedures and forms are available on our web support site at Emerson.com, or by calling the Micro Motion Customer Service department. 2 Configuration and Use Manual MS-00809-0200-1600 Contents May 2024 Contents Chapter 1 Before you begin....................................................................................................................... 7 1.1 About this manual....................................................................................................................... 7 1.2 Hazard messages........................................................................................................................ 7 1.3 Cybersecurity............................................................................................................................... 7 1.4 Related documentation............................................................................................................ 10 1.5 Communication methods.........................................................................................................10 Chapter 2 Quick start............................................................................................................................... 11 2.1 Power up the transmitter......................................................................................................... 11 2.2 Check meter status................................................................................................................... 11 2.3 Commissioning wizards............................................................................................................12 2.4 Make a startup connection to the transmitter...................................................................... 12 2.5 Set the transmitter clock.......................................................................................................... 12 2.6 View the licensed features (optional)......................................................................................13 2.7 Set informational parameters................................................................................................. 13 2.8 Characterize the meter (if required)....................................................................................... 14 2.9 Verify mass flow measurement............................................................................................... 16 2.10 Verify the zero..........................................................................................................................17 Chapter 3 Introduction to configuration and commissioning............................................................ 19 3.1 Security and write protection.................................................................................................. 19 3.2 Work with configuration files...................................................................................................23 Chapter 4 Configure process measurement..........................................................................................27 4.1 Configure Sensor Flow Direction Arrow ................................................................................ 27 4.2 Configure mass flow measurement........................................................................................28 4.3 Configure volume flow measurement for liquid applications.............................................32 4.4 Configure Gas Standard Volume (GSV) flow measurement.................................................36 4.5 Configure density measurement............................................................................................ 41 4.6 Configure temperature measurement...................................................................................43 4.7 Configure Pressure Measurement Unit .................................................................................45 4.8 Configure Velocity Measurement Unit .................................................................................. 46 Chapter 5 Configure process measurement applications................................................................... 47 5.1 Set up the API Referral application ........................................................................................ 47 5.2 Set up concentration measurement....................................................................................... 59 Chapter 6 Configure advanced options for process measurement....................................................71 6.1 Configure Response Time ....................................................................................................... 71 6.2 Detect and report two-phase flow.......................................................................................... 71 6.3 Configure Flow Rate Switch .....................................................................................................72 6.4 Configure events....................................................................................................................... 73 6.5 Configure totalizers and inventories...................................................................................... 75 6.6 Configure logging for totalizers and inventories.................................................................. 78 6.7 Configure Process Variable Fault Action ............................................................................... 79 Configuration and Use Manual 3 Contents May 2024 Configuration and Use Manual MS-00809-0200-1600 Chapter 7 Configure device options and preferences.......................................................................... 83 7.1 Configure the transmitter display........................................................................................... 83 7.2 Configure the transmitter response to alerts........................................................................88 Chapter 8 Integrate the meter with the control system..................................................................... 97 8.1 Channel configuration.............................................................................................................. 97 8.2 Configure I/O Channel A.......................................................................................................... 97 8.3 Configure I/O Channel B.......................................................................................................... 97 8.4 Configure an mA Output.......................................................................................................... 98 8.5 Configure a Frequency Output..............................................................................................106 8.6 Configure a Discrete Output..................................................................................................110 Chapter 9 Configure digital communications..................................................................................... 113 Chapter 10 Complete the configuration................................................................................................ 121 10.1 Test or tune the system using sensor simulation.............................................................121 10.2 Enable or disable write-protection......................................................................................122 Chapter 11 Transmitter operation..........................................................................................................125 11.1 View process and diagnostic variables...............................................................................125 11.2 View and acknowledge status alerts.................................................................................. 126 11.3 Read totalizer and inventory values................................................................................... 127 11.4 Start, stop, and reset totalizers and inventories............................................................... 127 Chapter 12 Operation using the batcher............................................................................................... 131 12.1 Run a batch............................................................................................................................ 131 12.2 Perform AOC calibration...................................................................................................... 134 Chapter 13 Measurement support..........................................................................................................137 13.1 Use Smart Meter Verification.............................................................................................. 137 13.2 Advanced Phase Measurement software.......................................................................... 145 13.3 Zero the meter.......................................................................................................................146 13.4 Set up pressure compensation........................................................................................... 148 13.5 Validate the meter................................................................................................................ 152 13.6 Perform a (standard) D1 and D2 density calibration........................................................154 13.7 Adjust concentration measurement with Trim Offset .....................................................156 13.8 Adjust concentration measurement with Trim Slope and Trim Offset ......................... 157 Chapter 14 Maintenance.......................................................................................................................... 161 14.1 Install a new transmitter license......................................................................................... 161 14.2 Upgrade the transmitter firmware..................................................................................... 162 14.3 Reboot the transmitter.........................................................................................................163 14.4 Battery replacement............................................................................................................. 163 Chapter 15 Log files, history files, and service files..............................................................................165 15.1 Generate history files........................................................................................................... 165 15.2 Generate service files........................................................................................................... 170 Chapter 16 Troubleshooting.................................................................................................................... 177 16.1 Status LED and device status...............................................................................................177 4 ® 9.1 Configure HART communications....................................................................................... 113 9.2 Configure Modbus communications.................................................................................... 117 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Contents May 2024 16.2 API Referral troubleshooting...............................................................................................177 16.3 Batch troubleshooting..........................................................................................................178 16.4 Concentration measurement troubleshooting................................................................. 179 16.5 Alert when connecting a core processor to a remote 1600 Transmitter....................... 180 16.6 Density measurement troubleshooting............................................................................181 16.7 Discrete Output troubleshooting........................................................................................183 16.8 Flow measurement troubleshooting..................................................................................184 16.9 Frequency Output troubleshooting....................................................................................186 16.10 mA Output troubleshooting.............................................................................................. 188 16.11 Status alerts, causes, and recommendations................................................................. 190 16.12 Check the cutoffs................................................................................................................ 206 16.13 Check the direction parameters........................................................................................206 16.14 Check the drive gain........................................................................................................... 207 16.15 Check for internal electrical problems............................................................................. 207 16.16 Check Frequency Output Fault Action .............................................................................208 16.17 Check the scaling of the Frequency Output.................................................................... 208 16.18 Check grounding.................................................................................................................208 16.19 Perform transmitter output tests..................................................................................... 209 16.20 Check Lower Range Value and Upper Range Value ...................................................... 212 16.21 Check mA Output Fault Action ......................................................................................... 212 16.22 Trim mA Output.................................................................................................................. 212 16.23 Check HART communications............................................................................................213 16.24 Check the pickoff voltage...................................................................................................213 16.25 Check power supply wiring................................................................................................214 16.26 Check for radio frequency interference (RFI).................................................................. 214 16.27 Checking process variables............................................................................................... 215 16.28 Check sensor-to-transmitter wiring..................................................................................218 16.29 Using sensor simulation for troubleshooting................................................................. 218 16.30 Check for two-phase flow (slug flow)............................................................................... 219 16.31 Check the sensor coils........................................................................................................ 219 Appendix A Using the transmitter display............................................................................................. 221 A.1 Components of the transmitter display............................................................................... 221 A.2 Access and use the display menus....................................................................................... 222 Appendix B Using ProLink III with the transmitter.............................................................................. 227 B.1 Basic information about ProLink III .....................................................................................227 B.2 Connect with ProLink III ........................................................................................................228 Appendix C Using a field communicator with the transmitter........................................................... 229 C.1 Basic information about field communicators....................................................................229 C.2 Connect with a field communicator .....................................................................................229 Appendix D Concentration measurement matrices..............................................................................231 D.1 Standard matrices for the Concentration Measurement application..............................231 D.2 Derived variables and calculated process variables.......................................................... 232 Appendix E Environmental compliance.................................................................................................. 233 E.1 RoHS and WEEE....................................................................................................................... 233 Configuration and Use Manual 5 Contents May 2024 6 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Before you begin May 2024 1 Before you begin 1.1 About this manual This manual helps you configure, commission, use, maintain, and troubleshoot a Micro Motion 1600 transmitter with configurable inputs and outputs. Important This manual assumes that: • The transmitter has been installed correctly and completely according to the instructions in the transmitter installation manual. • Users understand basic transmitter and sensor installation, configuration, and maintenance concepts and procedures. 1.2 Hazard messages This document uses the following criteria for hazard messages based on ANSI standards Z535.6-2011 (R2017). DANGER Serious injury or death will occur if a hazardous situation is not avoided. WARNING Serious injury or death could occur if a hazardous situation is not avoided. CAUTION Minor or moderate injury will or could occur if a hazardous situation is not avoided. NOTICE Data loss, property damage, hardware damage, or software damage can occur if a situation is not avoided. There is no credible risk of physical injury. Physical access WARNING Unauthorized personnel can potentially cause significant damage and/or misconfiguration of end users' equipment. Protect against all intentional or unintentional unauthorized use. Physical security is an important part of any security program and fundamental to protecting your system. Restrict physical access to protect users' assets. This is true for all systems used within the facility. 1.3 Cybersecurity 1.3.1 Defense-in-depth strategy Security capabilities The Micro Motion 1600 transmitter has several features that can help to protect it against either intentional or unintentional access and configuration changes. For each input and output, the secure set up is described: • Configuration Audit Trail log stored by the system (refer to Generate history files) Configuration and Use Manual 7 Before you begin May 2024 Configuration and Use Manual MS-00809-0200-1600 • Micro Motion 1600 signed firmware (refer to Upgrade the transmitter firmware) • Write protect physical lock switch (refer to Configure security for the display) Mitigation strategies Any device in the field is prone to a physical attack, which must be mitigated by physical security controls. If a device can access the worldwide internet, then it can be discoverable by malicious actors. As a result, field devices must be in a dedicated and actively-managed network. If an input or an output is described as insecure, it means that it is unencrypted (available in clear text) and does not have access control capabilities (for example there is no way to tell who is communicating with the transmitter). The following are inputs and outputs of the device that can be utilized for the Micro Motion 1600 device. Note If a protocol is licensed, you must call support to have it disabled. If a protocol is not licensed, it is disabled. (Refer to View the licensed features (optional)). • Local Operator Interface (LOI) – four-character passcode (refer to Configure security for the display) • USB service port – disable option (refer to Enable or disable the service port) • For the inputs and outputs available on this transmitter with different channels, refer to Rules for channel combinations. • Both HART and RS-485 Modbus are inherently insecure protocols. As a result, Emerson recommends using these protocols while the transmitter is within a physically secure environment, according to a company's security policy. The physical write protect switch controls all the interfaces. The physical write protect (dip) switch is located behind the display. More information can be found in Security and write protection. Security defense-in-depth measures The device is not intended to be directly connected to an enterprise or to an internet-facing network without a compensating control in place. Do not connect the device without mitigation measures in place. 1.3.2 Security hardening guidelines Product integration The device has optional applications for configuration and data viewing. When such applications are used, they must run on devices that are configured according to the security policy of the company using the device. Defense-in-depth strategy This transmitter device has been developed using secure coding principals and procedures, including threat modeling and security specific testing. It has several interfaces developed using the Secure Development Lifecycle (SDL), according to IEC 62443-4-1, which is the recognized standard for the oil and gas, and manufacturing industries. Configuring the device There are multiple ways to configure the Micro Motion 1600 device securely including: Issue: Local display allows the user a default passcode that is known publicly. Anyone in physical proximity to the device could log into it. Resolution: Change the passcode upon the first use and do not share passcodes. 8 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Before you begin May 2024 Issue: The USB service port is enabled by default. If a malicious actor has a physical access to the device, then they can install unauthorized software. Resolution: Emerson recommends disabling option when not needed and operating the device within a secure physical environment (refer to Enable or disable the service port). Defaults This transmitter is equipped with a Universal Service Port that works with USB type C connections, including compatible flash drives. There are multiple levels of security built into the transmitter service port that you can configure according to your needs and security standards. The service port offers the following features that enhance interface security: • The service port is inaccessible without physical access to the transmitter and requires removal of the terminal cover. • The service port can be disabled from the transmitter through software (refer to Enable or disable the service port). • The transmitter has a non-traditional operating system that is neither designed to execute programs nor to run scripts. • The display can be passcode protected to limit access to the USB file menu. • Overall transmitter security switches such as the write protect (dip) switch disallows configuration changes from all interfaces, including the Universal Service Port. More information can be found in Security and write protection. This transmitter is : • Designed to be implemented in an industrial automation control system (Level 1 of the Purdue Reference Architecture Model), with defense-in-depth security controls. • Not intended to be directly connected to an enterprise or to an internet-facing network without a compensating control in place. 1.3.3 Secure operation guidelines Operation of product Best practices of product operation: • Operate the device within a controlled and secured physical environment. • Operate the device within a controlled and secured network environment. • Manage all the accounts on the device according to the security policy of your company. Reporting security vulnerabilities Use Report a Vulnerability on Emerson.com for reporting vulnerabilities back to Emerson. Best security practices Best practices of product operation: • Do not connect the device to the worldwide net. • Apply security patches and updates as they are released. Maintain power to the device during the entire firmware update. • Change the passcodes and passwords frequently (at least once a month). • When entering the local display passcode, ensure no one else can view the passcode. Configuration and Use Manual 9 Before you begin May 2024 Configuration and Use Manual MS-00809-0200-1600 • Do not share passwords, passcodes, or other protected information. • Do not share the admin passcode. 1.3.4 Secure product disposal guidelines Instructions for product removal When the device needs to be disposed of, consider the following aspects of device removal: • Identify whether the device can be reused in another part of the process for either testing or training purposes. • Identify what data is stored on the device and sanitize this data using your organization's security policy. Consider restoring your factory configuration (see Restore the factory configuration). — Verify that the local display passcode is set to the default “AAAA". • If the device is ready for disposal, then it can be discarded or physically destroyed using your organization’s security policy. 1.4 Related documentation You can find all product documentation on the product documentation DVD shipped with the product or at Emerson.com. See any of the following documents for more information: • Micro Motion 1600 Transmitters Product Data Sheet • Micro Motion 1600 Transmitters with Configurable Inputs and Outputs: Configuration and Use Manual • Replacing the Electronics Assembly Module for the 1600 Transmitter • Sensor installation manual 1.5 Communication methods You can use several different communications methods to interface with the transmitter. You may use different methods in different locations or for different tasks. Interface Tool Display Capacitive touch buttons Universal Service Port ProLink™ III Modbus® over RS485 Port(1) Field Communicator HART®/Bell 202(2) (1) Modbus over RS 485 port only compatible with units sold with hardware board code M. (2) Field communicator only compatible with units sold with hardware board code A. For information about how to use the communication tools, see the appendices in this manual. 10 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Quick start May 2024 2 Quick start 2.1 Power up the transmitter The transmitter must be powered up for all configuration and commissioning tasks, or for process measurement. Procedure 1. Follow appropriate procedures to ensure that a new device in the control system does not interfere with existing measurement and control loops. 2. Verify that the cables are connected to the transmitter as described in the installation manual. 3. Verify that all transmitter and sensor covers and seals are closed. WARNING To prevent ignition of flammable or combustible atmospheres, ensure that all covers and seals are tightly closed. For hazardous area installations, applying power while housing covers are removed or loose can cause an explosion resulting in injury or death. 4. Turn on the electrical power at the power supply. Postrequisites Although the sensor is ready to receive process fluid shortly after power-up, the electronics can take up to 10 minutes to reach thermal equilibrium. Therefore, if this is the initial startup, or if power has been off long enough to allow components to reach ambient temperature, allow the electronics to warm up for approximately 10 minutes before relying on process measurements. During this warm-up period, you may observe minor measurement instability or inaccuracy. 2.2 Check meter status Check the meter for any error conditions that require user action or that affect measurement accuracy. Procedure 1. Wait approximately 10 seconds for the power-up sequence to complete. Immediately after power-up, the transmitter runs through diagnostic routines and checks for error conditions. During the power-up sequence, the Transmitter Initializing alert is active. This alert should clear automatically when the power-up sequence is complete. 2. Check the status LED. Table 2-1: Status LED and device status Status LED condition Device status Solid green No alerts are active. Solid yellow One or more alerts are active with Alert Severity = Out of Specification, Maintenance Required, or Function Check. Solid red One or more alerts are active with Alert Severity = Failure. Flashing yellow (1 Hz) Auto zero or SMV test in progress Flashing green An auto zero is being performed. Configuration and Use Manual 11 Quick start May 2024 Configuration and Use Manual MS-00809-0200-1600 Table 2-1: Status LED and device status (continued) Status LED condition Device status Status LED off Transmitter is not receiving power. Display is not seated or not functioning properly. 2.3 Commissioning wizards The transmitter menu includes a Guided Setup to help you move quickly through the most common configuration parameters. ProLink III™ also provides a commissioning wizard. By default, when the transmitter starts up, the Guided Setup menu is offered. You can choose to use it or not. You can also choose whether or not Guided Setup is displayed automatically. • To enter Guided Setup: — During transmitter setup, choose Yes at the prompt. — After transmitter setup, Menu → Startup Tasks • To control the automatic display of Guided Setup, choose Menu → Configuration → Guided Setup. For information on the ProLink III commissioning wizard, see the Micro Motion ProLink III with ProcessViz Software User Manual. As the commissioning wizards are self guided, they are not documented in detail. 2.4 Make a startup connection to the transmitter For all configuration tools except the display, you must have an active connection to the transmitter to configure the transmitter. Procedure Identify the connection type to use, and follow the instructions for that connection type in the appropriate appendix. Communications tool Connection type to use Instructions ProLink III Service port Using ProLink III with the transmitter Field communicator HART Using a field communicator with the transmitter ™ 2.5 Set the transmitter clock Display Menu → Configuration → Time/Date/Tag ProLink III Device Tools → Configuration → Transmitter Clock Field communicator Device Settings → Setup Overview → Real Time Clock The transmitter clock provides timestamp data for alerts, service logs, history logs, and all other timers and dates in the system. You can set the clock for your local time or for any standard time you want to use. Note You may find it convenient to set all of your transmitter clocks to the same time, even if the transmitters are in different time zones. To aid in record keeping convenience, set transmitter clocks located in different time zones to the same time. 12 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Quick start May 2024 Procedure 1. Select the time zone that you want to use. 2. If you need a custom time zone, select Special Time Zone and enter your time zone as a difference from UTC (Coordinated Universal Time). 3. Set the time appropriately. Note The transmitter does not adjust for Daylight Savings Time. If you observe Daylight Savings Time, you must reset the transmitter clock manually. 4. Set the month, day, and year. The transmitter tracks the year and automatically adds a day for leap years. 2.6 View the licensed features (optional) Display Menu → About → Licenses → Licensed Features ProLink III Device Tools → Device Information → Licensed Features Field communicator Device Settings → Device Information → Licenses You can view the licensed features to ensure that the transmitter was ordered with the required features. The transmitter license controls the features that are enabled on the transmitter, including both software applications and I/O channels. Licensed features are purchased and available for permanent use. The options model code represents the licensed features. A trial license allows you to explore features before purchasing. The trial license enables the specified features for a limited number of days. This number is displayed for reference. At the end of this period, the feature will no longer be available. To purchase additional features or request a trial license, either write down or record the Unique ID Number and current license key from your transmitter and then contact customer service. To enable the additional features or trial license, you will need to install the new license on the transmitter. 2.7 Set informational parameters Display Menu → Configuration → Device Information ProLink III Device Tools → Configuration → Informational Parameters Field communicator Device Settings → Device Information You can set several parameters that identify or describe the transmitter and sensor. These parameters are not used in processing and are not required. Procedure 1. Set informational parameters for the transmitter. a) Set Transmitter Serial Number to the serial number of your transmitter. The transmitter serial number is provided on the metal tag that is attached to the transmitter housing. b) Set Descriptor to any desired description of this transmitter or measurement point. Configuration and Use Manual 13 Quick start May 2024 Configuration and Use Manual MS-00809-0200-1600 c) Set Message to any desired message. d) Verify that Model Code (Base) is set to the base model code of the transmitter. The base model code completely describes your transmitter, except for the features that can be licensed independently. The base model code is set at the factory. e) Set Model Code (Options) to the options model code of the transmitter. The options model code describes the independent features that have been licensed for this transmitter. The original options model code is set at the factory. If you license additional options for this transmitter, Emerson will supply an updated options model code. For a field communicator, configuring model code options is not available for this release. 2. Set informational parameters for the sensor. a) Set Sensor Serial Number to the serial number of the sensor connected to this transmitter. The sensor serial number is provided on the metal tag that is attached to the sensor case. b) Set Sensor Material to the material used for the sensor. c) Set Flange Type to the type of flange that was used to install the sensor. Sensor Type is set or derived during characterization. 2.8 Characterize the meter (if required) Display Menu → Configuration → Sensor Parameters ProLink III Device Tools → Calibration Data Field communicator Device Settings → Setup Overview → Sensor Characterizing the meter adjusts the 1600 transmitter to match the unique traits of the sensor it is paired with. The characterization parameters (also called calibration parameters) describe the sensor’s sensitivity to flow, density, and temperature. Depending on your sensor type, different parameters are required. Values for your sensor are provided on the sensor tag or the calibration certificate. • If your transmitter was ordered with a sensor, it was characterized at the factory. However, you should still verify the characterization parameters. • Perform a characterization whenever you replace a core processor or the transmitter. Note If the transmitter and sensor are purchased together, you do not need to characterize the meter because this step was performed at the factory prior to shipping. Note The Micro Motion 1600 Transmitter derives Sensor Type from the user-specified values for FCF and K1. Procedure 1. Set the flow calibration factor: FCF (also called Flow Cal or Flow Calibration Factor). Be sure to include both decimal points and all zeros. 2. Set the density characterization parameters: D1, D2, TC, K1, K2, and FD. (TC is sometimes shown as DT.) 3. Apply the changes as required by the tool you are using. 14 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Quick start May 2024 The transmitter identifies your sensor type, and characterization parameters are adjusted as required: • If Sensor Type changed from Curved Tube to Straight Tube, five characterization parameters are added to the list. • If Sensor Type changed from Straight Tube to Curved Tube, five characterization parameters are removed from the list. • If Sensor Type did not change, the list of characterization parameters does not change. 4. T-Series sensors only: Set the additional characterization parameters listed below: Characterization parameter type Parameters Flow FTG, FFQ Density DTG, DFQ1, DFQ2 2.8.1 Sample sensor tags Figure 2-1: Tag on newer curved-tube sensors (all sensors except T-Series) 2.8.2 Flow calibration parameters (FCF, FT) Two separate values are used to describe flow calibration: a 6-character FCF value and a 4-character FT value. They are provided on the sensor tag. Both values contain decimal points. During characterization, these are entered as a single 10-character string. The 10-character string is called either Flowcal or FCF. If your sensor tag shows the FCF and the FT values separately and you need to enter a single value, concatenate the two values to form the single parameter value, retaining both decimal points. Concatenating FCF and FT FCF = x.xxxx FT = y.yy Flow calibration parameter: x.xxxxy.yy Configuration and Use Manual 15 Quick start May 2024 Configuration and Use Manual MS-00809-0200-1600 2.8.3 Density calibration parameters (D1, D2, K1, K2, FD, DT, TC) Density calibration parameters are typically on the sensor tag and the calibration certificate. If your sensor tag does not show a D1 or D2 value: • For D1, enter the Dens A or D1 value from the calibration certificate. This value is the line-condition density of the low-density calibration fluid. Micro Motion uses air. If you cannot find a Dens A or D1 value, enter 0.001 g/cm3. • For D2, enter the Dens B or D2 value from the calibration certificate. This value is the line-condition density of the high-density calibration fluid. Micro Motion uses water. If you cannot find a Dens B or D2 value, enter 0.998 g/cm3 . If your sensor tag does not show a K1 or K2 value: • For K1, enter the first five digits of the density calibration factor. In this sample tag, this value is shown as 12500. • For K2, enter the second five digits of the density calibration factor. In this sample tag, this value is shown as 14286. Figure 2-2: K1, K2, and TC values in the density calibration factor If your sensor does not show an FD value, contact customer service. If your sensor tag does not show a DT or TC value, enter the last four characters of the density calibration factor. In the sample tag shown above, the value is shown as 4.44. Do not confuse the Meter Factor line on the pictured sensor tag with any meter factor settings discussed in this manual. 2.9 Verify mass flow measurement Check to see that the mass flow rate reported by the transmitter is accurate. You can use any available method. Procedure • Read the value for Mass Flow Rate on the transmitter display. • Connect to the transmitter with ProLink III and read the value for Mass Flow Rate in the Process Variables panel. • Connect to the transmitter with a field communicator and read the value for Mass Flow Rate. 16 Online → Overview → Mass Flow Rate Emerson.com Configuration and Use Manual MS-00809-0200-1600 Quick start May 2024 Postrequisites If the reported mass flow rate is not accurate: • Check the characterization parameters. • Review the troubleshooting suggestions for flow measurement issues. For information about modifying these values, refer to Configure mass flow measurement. 2.10 Verify the zero Display Menu → Service Tools → Verification & Calibration → Meter Zero → Zero Verification ProLink III Device Tools → Calibration → Smart Zero Verification and Calibration → Verify Zero Field communicator Device Settings → Calibration → Zero Calibration → Perform Zero Verify Verifying the zero helps you determine if the stored zero value is appropriate to your installation, or if a field zero can improve measurement accuracy. Important In most cases, the factory zero is more accurate than the field zero. Do not zero the meter unless one of the following is true: • The zero is required by site procedures. • The stored zero value fails the zero verification procedure. Do not verify the zero or zero the meter if a high-severity alert is active. Correct the problem, then verify the zero or zero the meter. You may verify the zero or zero the meter if a low-severity alert is active. Procedure 1. Prepare the meter: a) Allow the meter to warm up for at least 20 minutes after applying power. b) Run the process fluid through the sensor until the sensor temperature reaches the normal process operating temperature. c) Stop flow through the sensor by shutting the downstream valve, and then the upstream valve if available. d) Verify that the sensor is blocked in, that flow has stopped, and that the sensor is completely full of process fluid. 2. Start the zero verification procedure, and wait until it completes. 3. If the zero verification procedure fails: a) Confirm that the sensor is completely blocked in, that flow has stopped, and that the sensor is completely full of process fluid. b) Verify that the process fluid is not flashing or condensing, and that it does not contain particles that can settle out. c) Repeat the zero verification procedure. d) If it fails again, zero the meter. Postrequisites Restore normal flow through the sensor by opening the valves. Configuration and Use Manual 17 Quick start May 2024 Configuration and Use Manual MS-00809-0200-1600 Related information Zero the meter 18 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Introduction to configuration and commissioning May 2024 3 Introduction to configuration and commissioning 3.1 Security and write protection The transmitter has several features that can help to protect it against intentional or unintentional access and configuration changes. • When locked, the mechanical lock switch on the front of the upper puck prevents any configuration changes to the transmitter from any local or remote configuration tool. • When enabled, the software setting Write Protection prevents any configuration changes. The setting can only be enabled if the transmitter does not have a display. • If the Universal Service Port (USP) is disabled, the port cannot be used by any service tool to communicate with or make changes to the transmitter. • When enabled, Security prevents any configuration changes being made from the display unless the appropriate password is entered. 3.1.1 Enable or disable the service port Display Menu → Configuration → Security → Service Port ProLink III Device Tools → Configuration → Transmitter Display → Display Security Field communicator Device Settings → Security → Enable/Disable Service Port The service port is enabled by default. You can use the service port for connecting to ProLink III and for transferring files. If you want to completely prevent it from being used, you can disable it. Note Enabling or disabling the service port will not take effect until power has been cycled to the transmitter. WARNING Do not use the service port if the transmitter is in a hazardous area because using the service port means that you must open the transmitter wiring compartment. Opening the wiring compartment in a hazardous area while the transmitter is powered up can cause an explosion resulting in injury or death. 3.1.2 Enable or disable write-protection Upper puck Use the mechanical switch on the upper puck. ProLink III Not available Field communicator Device Settings → Security → Security Switch Status → Write Protect When enabled, Write-Protection prevents changes to the transmitter configuration. You can perform all other functions, and you can view the transmitter configuration parameters. Note Write protection is available only by removing the display in order to access the upper puck component and using the lock switch to set the switch ON. Configuration and Use Manual 19 Introduction to configuration and commissioning May 2024 Configuration and Use Manual MS-00809-0200-1600 Figure 3-1: Removing the transmitter housing cover A. Display Component B. Upper Puck Component 20 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Introduction to configuration and commissioning May 2024 Figure 3-2: Setting Switch 1 ON (to the left) to Set Write-Protection A. Switch 1 Write-protecting the transmitter primarily prevents accidental changes to configuration, not intentional changes. Any user who can make changes to the configuration can disable write protection. 3.1.3 Configure security for the display Display Menu → Configuration → Security → Display Security ProLink III Device Tools → Configuration → Transmitter Display → Display Security Field communicator Device Settings → Display → Display Security When using the display, you can require users to enter a password to do any of the following tasks: • Enter the main menu • Change a parameter • Access alert data through the display • Start, stop, or reset totalizers or inventories via the context menu The display password can be the same or different from the totalizer/inventory context menu control password. If different, the display password is used to reset, start, and stop totalizers or inventories using Menu → Operations → Totalizers. Configuration and Use Manual 21 Introduction to configuration and commissioning May 2024 Configuration and Use Manual MS-00809-0200-1600 Procedure 1. Configure Password Required as desired. Option Description At Write When an user chooses an action that leads to a configuration change, they are prompted to enter the display password. Enter Menu When the menu is selected from the process variable screen, the display password will be immediately required if Password Required is set. Never (default) When a user chooses an action that leads to a configuration change, they are prompted to enter a specific button sequence ( ⇦⇧⇩⇨). This is designed to protect against accidental changes to configuration. It is not a security measure. 2. If the At Write or Enter Menu option was selected, enable or disable alert security as desired. Option Description Enabled If an alert is active, the alert symbol ⓘ is shown in the lower right corner of the display but the alert banner is not displayed. If the operator attempts to enter the alert menu, they are prompted to enter the display password. Disabled If an alert is active, the alert symbol ⓘ is shown in the lower right corner of the display and the alert banner is displayed automatically. No password or confirmation is required to enter the alert menu. Restriction You cannot set Password Required to Never and enable alert security. • If you did not enable Password Required, alert security is disabled and cannot be enabled. • Alert security is disabled automatically if you set Password Required to Never after: — Password Required is initially set to either At Write or Enter Menu. — Alert security is enabled. 3. If Password Required has been set to At Write or Enter Menu, you will be prompted to enter the desired password. • Default: AAAA • Range: Any four alphanumeric characters • Password Required must be set to At Write or Enter Menu to enable the totalizer/inventory control context menu password option. Important If you enable Password Required but you do not change the display password, the transmitter will post a configuration alert. 22 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Introduction to configuration and commissioning May 2024 4. Configure Main Menu Available as desired. Option Description Enabled The local display Menu option from the process variable screen will be accessible. Disabled The local display Menu option from the process variable screen will not be accessible. Important Once Main Menu Available is disabled, it cannot be enabled from the local display. Use another configuration tool, such as ProLink III, to re-enable main menu access from the local display. 3.2 Work with configuration files You can save the current transmitter configuration in two forms: a backup file and a replication file. Tip You can use a saved configuration file to change the nature of the transmitter quickly. This might be convenient if the transmitter is used for different applications or different process fluids. Backup files Contain all parameters. They are used to restore the current device if required. The .spare extension is used to identify backup files. Replication files Contain all parameters except the device-specific parameters, e.g., calibration factors or meter factors. They are used to replicate the transmitter configuration to other devices. The .xfer extension is used to identify replication files. 3.2.1 Save a configuration file using the display Procedure • To save the current configuration to the transmitter's internal memory: a) Choose Menu → Configuration → Save/Restore Config → Save Config to Memory. b) When prompted to load 1600 device configuration data from a file, click the on my 1600 device internal memory radio button. c) Enter the name for this configuration file. The configuration file is saved to internal memory as yourname.spare. 3.2.2 Save a configuration file using ProLink III Note When you use ProLink III format for configuration files, you can specify configuration parameters individually or by groups. Therefore, you can use this format for both backup and replication. Prerequisites If you are planning to use the USP (Universal Service Port), the port must be enabled. It is enabled by default. However, if you need to enable or disable it using the display, choose Menu → Configuration → Security and set Service Port to On. Procedure • To save the current configuration to your PC, in 1600 format: a) Choose Device Tools → Configuration Transfer → Save Configuration. Configuration and Use Manual 23 Introduction to configuration and commissioning May 2024 Configuration and Use Manual MS-00809-0200-1600 b) Select On my computer in 1600 device file format and click Next. c) Select Save. d) Browse to the desired location, then enter the name for this configuration file. e) Set the file type. — To save a backup file, set the file type to Backup. — To save a replication file, set the file type to Transfer. f) Select Save. The configuration file is saved to the specified location as yourname.spare or yourname.xfer. • To save the current configuration to your PC, in ProLink III format: a) Choose Device Tools → Configuration Transfer → Save Configuration. b) Select On my computer in ProLink III file format and click Next. c) Select Save. d) Select the configuration parameters to be included in this file. — To save a backup file, select all parameters. — To save a replication file, select all parameters except device-specific parameters. e) Select Save. f) Browse to the desired location, then enter the name for this configuration file. g) Set the file type to ProLink configuration file. h) Select Start Save. The configuration file is saved to the specified location as yourname.pcfg. 3.2.3 Load a configuration file using the display Prerequisites You must have a backup file or a replication file available for use in internal memory. Procedure • To load a configuration file to the transmitter's internal memory: a) Ensure the configuration file is in the Config folder. b) Upload the configuration file through the USP file by specifying Device Tools → Configuration Transfer → Load Configuration. c) When prompted to load 1600 device configuration data from a file, click the on my 1600 device internal memory radio button. d) Choose Backup and click Restore. The configuration file is loaded to internal memory as yourname.spare. 24 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Introduction to configuration and commissioning May 2024 3.2.4 Load a configuration file using ProLink III You can load a configuration file to a transmitter's internal memory, as well as loading a backup file or a replication file. Two PC file formats are supported: the 1600 format and the ProLink III format. Note When you use ProLink III format for configuration files, you can specify configuration parameters individually or by groups. Therefore, you can use this format for both backup and replication. Procedure • To load a backup file or replication file in 1600 format from the PC: a) Choose Device Tools → Configuration Transfer → Load Configuration. b) Select On my computer in 1600 device file format and select Next. c) Select Restore. d) Set the file type. — To load a backup file, set the file type to Backup. — To load a replication file, set the file type to Transfer. e) Navigate to the file you want to load, and select it. The parameters are written to the internal memory, and the new settings become effectively immediately. • To load a file in ProLink III format from the PC: a) Choose Device Tools → Configuration Transfer → Load Configuration. b) Select On my computer in ProLink III file format and select Next. c) Select the parameters that you want to load. d) Select Load. e) Set the file type to Configuration file. f) Navigate to the file you want to load, and select it. g) Select Start Load. The parameters are written to the internal memory, and the new settings become effectively immediately. 3.2.5 Replicate a transmitter configuration Replicating a transmitter configuration is a fast method to set up similar or identical measurement points. Procedure 1. Configure a transmitter and verify its operation and performance. 2. Use any available method to save a replication file from that transmitter. 3. Use any available method to load the replication file to another transmitter. Configuration and Use Manual 25 Introduction to configuration and commissioning May 2024 Configuration and Use Manual MS-00809-0200-1600 4. At the replicated transmitter, set device-specific parameters and perform device-specific procedures: a) Set the clock. b) Set the tag, long tag, IP address, and related parameters. c) Characterize the transmitter. d) Perform zero validation and take any recommended actions. e) Perform loop tests and take any recommended actions, including mA Output trim. f) Use sensor simulation to verify transmitter response. 5. At the replicated transmitter, make any other configuration changes. 6. Follow your standard procedures to ensure that the replicated transmitter is performing as desired. 26 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 4 Configure process measurement 4.1 Configure Sensor Flow Direction Arrow Display Menu → Configuration → Process Measurement → Flow Variables → Flow Direction ProLink III Device Tools → Configuration → Process Measurement → Flow → Sensor Direction Field communicator Device Settings → Process Configuration → Flow → Sensor Direction Sensor Flow Direction Arrow is used to accommodate installations in which the Flow arrow on the sensor does not match the majority of the process flow. This typically happens when the sensor is either accidentally installed backwards or conditions require that it be installed backwards. Sensor Flow Direction Arrow interacts with mA Output Direction, Frequency Output Direction, and Totalizer Direction to control how flow is reported by the outputs and accumulated by the totalizers and inventories. The Sensor Flow Direction Arrow also affects how flow is reported on the transmitter display and via digital communications. Figure 4-1: Flow arrow on sensor A. Flow arrow B. Actual flow direction Procedure Set Sensor Flow Direction Arrow as appropriate. Option Description With Arrow The majority of flow through the sensor matches the Flow arrow on the sensor. Actual forward flow is processed as forward flow. Against Arrow The majority of flow through the sensor is opposite to the Flow arrow on the sensor. Actual forward flow is processed as reverse flow. Tip Micro Motion sensors are bidirectional. Measurement accuracy is not affected by actual flow direction or the setting of Sensor Flow Direction Arrow. Sensor Flow Direction Arrow controls only whether actual flow is processed as forward flow or reverse flow. Configuration and Use Manual 27 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 Related information Configure mA Output Direction Configure Frequency Output Direction Configure Discrete Output Source Configure totalizers and inventories Effect of Sensor Flow Direction Arrow on digital communications 4.2 Configure mass flow measurement The mass flow measurement parameters control how mass flow is measured and reported. The mass total and mass inventory are derived from the mass flow data. 4.2.1 Configure Mass Flow Measurement Unit Display Menu → Configuration → Process Measurement → Flow Variables → Mass Flow Settings → Units ProLink III Device Tools → Configuration → Process Measurement → Flow → Mass Flow Rate Unit Field communicator Device Settings → Process Configuration → Mass Flow Rate → Mass Flow Rate Unit Mass Flow Measurement Unit specifies the unit of measure that will be used for the mass flow rate. The default unit used for mass total and mass inventory is derived from this unit. Procedure Set Mass Flow Measurement Unit to the unit you want to use. Default: g/sec (grams per second) Tip If the measurement unit you want to use is not available, you can define a special measurement unit. Options for Mass Flow Measurement Unit The transmitter provides a standard set of measurement units for Mass Flow Measurement Unit, plus one user-defined special measurement unit. Different communications tools may use different labels for the units. Unit description Label Display ProLink III Field communicator Grams per second gram/s g/sec g/s Grams per minute gram/min g/min g/min Grams per hour gram/h g/hr g/h Kilograms per second kg/s kg/sec kg/s Kilograms per minute kg/min kg/min kg/min Kilograms per hour kg/h kg/hr kg/h Kilograms per day kg/d kg/day kg/d Metric tons per minute MetTon/min mTon/min MetTon/min Metric tons per hour MetTon/h mTon/hr MetTon/h Metric tons per day MetTon/d mTon/day MetTon/d Pounds per second lb/s lbs/sec lb/s Pounds per minute lb/min lbs/min lb/min 28 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 Label Unit description Display ProLink III Field communicator Pounds per hour lb/h lbs/hr lb/h Pounds per day lb/d lbs/day lb/d Short tons (2000 pounds) per minute STon/min sTon/min STon/min Short tons (2000 pounds) per hour STon/h sTon/hr STon/h Short tons (2000 pounds) per day STon/d sTon/day STon/d Long tons (2240 pounds) per hour LTon/h lTon/hr LTon/h Long tons (2240 pounds) per day LTon/d lTon/day LTon/d Special unit SPECIAL Special Special Define a special measurement unit for mass flow Display Menu → Configuration → Process Measurement → Flow Variables → Mass Flow Settings → Units → SPECIAL ProLink III Device Tools → Configuration → Process Measurement → Flow → Mass Flow Rate Unit → Special Field communicator Device Settings → Process Configuration → Optional Setup → Special Units Procedure 1. Specify Base Mass Unit. Base Mass Unit is the existing mass unit that the special unit will be based on. 2. Specify Base Time Unit. Base Time Unit is the existing time unit that the special unit will be based on. 3. Calculate Mass Flow Conversion Factor as follows: a) x base units = y special units b) Mass Flow Conversion Factor = x ÷ y 4. Enter Mass Flow Conversion Factor. The original mass flow rate value is divided by this value. 5. Set Mass Flow Label to the name you want to use for the mass flow unit. Maximum of 8 characters. 6. Set Mass Total Label to the name you want to use for the mass total and mass inventory unit. Maximum of 8 characters. The special measurement unit is stored in the transmitter. You can configure the transmitter to use the special measurement unit at any time. Example: Defining a special measurement unit for mass flow To measure mass flow in ounces per second (oz/sec): 1. Set Base Mass Unit to Pounds (lb). 2. Set Base Time Unit to Seconds (sec). 3. Calculate Mass Flow Conversion Factor: a. 1 lb/sec = 16 oz/sec b. Mass Flow Conversion Factor = 1 ÷ 16 = 0.0625 Configuration and Use Manual 29 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 4. Set Mass Flow Conversion Factor to 0.0625. 5. Set Mass Flow Label to oz/sec. 6. Set Mass Total Label to oz. 4.2.2 Configure Flow Damping Display Menu → Configuration → Process Measurement → Flow Variables → Flow Damping ProLink III Device Tools → Configuration → Process Measurement → Flow → Flow Rate Damping Field communicator Device Settings → Process Configuration → Flow → Flow Damping Flow Damping controls the amount of damping that will be applied to the measured mass flow rate. It affects flow rate process variables that are based on the measured mass flow rate. This includes volume flow rate and gas standard volume flow rate. Flow Damping also affects specialized flow rate variables such as temperature-corrected volume flow rate (API Referral) and net mass flow rate (concentration measurement). Damping is used to smooth out small, rapid fluctuations in process measurement. The damping value specifies the time period, in seconds, over which the transmitter will spread changes in the process variable. At the end of the interval, the internal value of the process variable (the damped value) will reflect 63% of the change in the actual measured value. Procedure Set Flow Damping to the value you want to use. • Default: 0.64 seconds • Range: 0 seconds to 60 seconds Note If a number greater than 60 is entered, it is automatically changed to 60. Tip • A high damping value makes the process variable appear smoother because the reported value changes slowly. • A low damping value makes the process variable appear more erratic because the reported value changes more quickly. • The combination of a high damping value and rapid, large changes in flow rate can result in increased measurement error. • Whenever the damping value is non-zero, the reported measurement will lag the actual measurement because the reported value is being averaged over time. • In general, lower damping values are preferable because there is less chance of data loss, and less lag time between the actual measurement and the reported value. • The transmitter automatically rounds off any entered damping value to the nearest valid value. Therefore, the recommended damping value for gas applications should be 3.2 seconds. If you enter 2.56, the transmitter will round it off to 3.2. • For filling applications, Emerson recommends using the default value of 0.04 seconds. • For gas applications, the damping should be set initially to 3.2 seconds. For most liquid applications, the default setting of 0.64 seconds should suffice. 30 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 Effect of flow damping on volume measurement Flow damping affects volume measurement for liquid volume data. Flow damping also affects volume measurement for gas standard volume data. The transmitter calculates volume data from the damped mass flow data. Interaction between Flow Damping and mA Output Damping In some circumstances, both Flow Damping and mA Output Damping are applied to the reported mass flow value. Flow Damping controls the rate of change in flow process variables. mA Output Damping controls the rate of change reported through mA Output. If mA Output Process Variable is set to Mass Flow Rate, and both Flow Damping and mA Output Damping are set to non-zero values, flow damping is applied first, and the added damping calculation is applied to the result of the first calculation. 4.2.3 Configure Mass Flow Cutoff Display Menu → Configuration → Process Measurement → Flow Variables → Mass Flow Settings → Low Flow Cutoff ProLink III Device Tools → Configuration → Process Measurement → Flow → Mass Flow Cutoff Field communicator Device Settings → Process Configuration → Mass Flow Rate → Mass Flow Cutoff Mass Flow Cutoff specifies the lowest mass flow rate that will be reported as measured. All mass flow rates below this cutoff will be reported as 0. Procedure Set Mass Flow Cutoff to the value you want to use. • Default: A sensor-specific value set at the factory. If your transmitter was ordered without a sensor, the default may be 0.0. • Recommendation: 0.5% of maximum flow rate of the attached sensor. See the sensor specifications. Important Do not use your meter for measurement with Mass Flow Cutoff set to 0.0 g/sec. Ensure that Mass Flow Cutoff is set to a nonzero value that is appropriate for your sensor and process conditions. Effect of Mass Flow Cutoff on volume measurement Mass Flow Cutoff does not affect volume measurement. Volume data is calculated from the actual mass data rather than the reported value. Volume flow has a separate Volume Flow Cutoff that is not affected by the Mass Flow Cutoff value. Interaction between Mass Flow Cutoff and mA Output Cutoff Mass Flow Cutoff defines the lowest mass flow value that the transmitter will report as measured. mA Output Cutoff defines the lowest flow rate that will be reported through mA Output. If mA Output Process Variable is set to Mass Flow Rate, the mass flow rate reported through mA Output is controlled by the higher of the two cutoff values. Mass Flow Cutoff affects all reported values and values used in other transmitter behavior (e.g., events defined on mass flow). mA Output Cutoff affects only mass flow values reported through mA Output. Configuration and Use Manual 31 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 Example: Cutoff interaction with mA Output Cutoff lower than Mass Flow Cutoff Configuration: • mA Output Process Variable: Mass Flow Rate • Frequency Output Process Variable: Mass Flow Rate • mA Output Cutoff: 10 g/sec • Mass Flow Cutoff: 15 g/sec Result: If the mass flow rate drops below 15 g/sec, mass flow will be reported as 0, and 0 will be used in all internal processing. Example: Cutoff interaction with mA Output Cutoff higher than Mass Flow Cutoff Configuration: • mA Output Process Variable: Mass Flow Rate • Frequency Output Process Variable: Mass Flow Rate • mA Output Cutoff: 15 g/sec • Mass Flow Cutoff: 10 g/sec Result: • If the mass flow rate drops below 15 g/sec but not below 10 g/sec: — The mA Output will report zero flow. — The Frequency Output will report the actual flow rate, and the actual flow rate will be used in all internal processing. • If the mass flow rate drops below 10 g/sec, both outputs will report zero flow, and 0 will be used in all internal processing. 4.3 Configure volume flow measurement for liquid applications The volume flow measurement parameters control how liquid volume flow is measured and reported. The volume total and volume inventory are derived from volume flow data. Restriction You cannot implement both liquid volume flow and gas standard volume flow at the same time. Choose one or the other. 4.3.1 Configure Volume Flow Type for liquid applications Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Flow Type → Liquid ProLink III Device Tools → Configuration → Process Measurement → Flow → Volume Flow Type → Liquid Volume Field communicator Device Settings → Process Configuration → Volume Flow Rate Volume Flow Type controls whether liquid or gas standard volume flow measurement will be used. Restriction Gas standard volume measurement is incompatible with the following applications: • 32 API Referral Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 • Concentration measurement • Advanced Phase Measurement — liquid with gas For these applications, set Volume Flow Type to Liquid. Procedure Set Volume Flow Type to Liquid. 4.3.2 Configure Volume Flow Measurement Unit for liquid applications Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Units ProLink III Device Tools → Configuration → Process Measurement → Flow → Volume Flow Rate Unit Field communicator Device Settings → Process Configuration → Volume Flow Rate → Volume Flow Rate Unit Volume Flow Measurement Unit specifies the unit of measurement that will be displayed for the volume flow rate. The unit used for the volume total and volume inventory is based on this unit. Prerequisites Before you configure Volume Flow Measurement Unit, ensure that Volume Flow Type is set to Liquid. Procedure Set Volume Flow Measurement Unit to the unit you want to use. Default: l/sec (liters per second) Tip If the measurement unit you want to use is not available, you can define a special measurement unit. Options for Volume Flow Measurement Unit for liquid applications The transmitter provides a standard set of measurement units for Volume Flow Measurement Unit, plus one user-defined measurement unit. Different communications tools may use different labels for the units. Unit description Label Display ProLink III Field communicator Cubic feet per second ft3/s ft3/sec Cuft/s Cubic feet per minute ft3/min ft3/min Cuft/min Cubic feet per hour ft3/h ft3/hr Cuft/h Cubic feet per day ft3/d ft3/day Cuft/d Cubic meters per second m3/s m3/sec Cum/s Cubic meters per minute m3/min m3/min Cum/min Cubic meters per hour m3/h m3/hr Cum/h Cubic meters per day m3/d m3/day Cum/d U.S. gallons per second gal/s US gal/sec gal/s U.S. gallons per minute gal/m US gal/min gal/min U.S. gallons per hour gal/h US gal/hr gal/h U.S. gallons per day gal/d US gal/day gal/d Configuration and Use Manual 33 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 Label Unit description Display ProLink III Field communicator Million U.S. gallons per day MMgal/d mil US gal/day MMgal/d Liters per second L/s l/sec L/s Liters per minute L/min l/min L/in Liters per hour L/h l/hr L/h Million liters per day MML/d mil l/day ML/d Imperial gallons per second Impgal/s Imp gal/sec Impgal/s Imperial gallons per minute Impgal/m Imp gal/min Impgal/min Imperial gallons per hour Impgal/h Imp gal/hr Impgal/h Imperial gallons per day Impgal/d Imp gal/day Impgal/d Barrels per second(1) bbl/s barrels/sec bbl/s Barrels per minute (1) bbl/min barrels/min bbl/min Barrels per hour(1) bbl/h barrels/hr bbl/h Barrels per day (1) bbl/d barrels/day bbl/d Beer barrels per second(2) Beer bbl/s Beer barrels/sec Beer bbl/s Beer barrels per minute(2) Beer bbl/min Beer barrels/min Beer bbl/min Beer barrels per hour (2) Beer bbl/h Beer barrels/hr Beer bbl/h Beer barrels per day (2) Beer bbl/d Beer barrels/day Beer bbl/d Special unit SPECIAL Special Special (1) Unit based on oil barrels (42 U.S. gallons). (2) Unit based on U.S. beer barrels (31 U.S. gallons). Define a special measurement unit for volume flow Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Units → SPECIAL ProLink III Device Tools → Configuration → Process Measurement → Flow → Volume Flow Rate Unit → Special Field communicator Device Settings → Process Configuration → Optional Setup → Special Units Procedure 1. Specify Base Volume Unit. Base Volume Unit is the existing volume unit that the special unit will be based on. 2. Specify Base Time Unit. Base Time Unit is the existing time unit that the special unit will be based on. 3. Calculate Volume Flow Conversion Factor as follows: a) x base units = y special units b) Volume Flow Conversion Factor = x ÷ y 4. Enter Volume Flow Conversion Factor. 34 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 The original volume flow rate value is divided by this conversion factor. 5. Set Volume Flow Label to the name you want to use for the volume flow unit. Maximum of 8 characters. 6. Set Volume Total Label to the name you want to use for the volume total and volume inventory unit. Maximum of 8 characters. The special measurement unit is stored in the transmitter. You can configure the transmitter to use the special measurement unit at any time. Example: Defining a special measurement unit for volume flow To measure volume flow in pints per second (pints/sec): 1. Set Base Volume Unit to Gallons (gal). 2. Set Base Time Unit to Seconds (sec). 3. Calculate the conversion factor: a. 1 gal/sec = 8 pints/sec b. Volume Flow Conversion Factor = 1 ÷ 8 = 0.1250 4. Set Volume Flow Conversion Factor to 0.1250. 5. Set Volume Flow Label to pints/sec. 6. Set Volume Total Label to pints. 4.3.3 Configure Volume Flow Cutoff Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Low Flow Cutoff ProLink III Device Tools → Configuration → Process Measurement → Flow → Volume Flow Cutoff Field communicator Device Settings → Process Configuration → Volume Flow Rate → Volume Flow Rate Cutoff Volume Flow Cutoff specifies the lowest volume flow rate that will be reported as measured. All volume flow rates below this cutoff are reported as 0. Procedure Set Volume Flow Cutoff to the value you want to use. • Default: 0.01/sec (liters per second) • Range: 0 l/sec to x l/sec, where x is the sensor’s flow calibration factor, multiplied by 0.0002 • Recommendation: 0.5% of the sensor's maximum rated volumetric flow rate based on water. Interaction between Volume Flow Cutoff and mAO Cutoff Volume Flow Cutoff defines the lowest liquid volume flow value that the transmitter will report as measured. mAO Cutoff defines the lowest flow rate that will be reported through mA Output. If mA Output Process Variable is set to Volume Flow Rate, the volume flow rate reported through mA Output is controlled by the higher of the two cutoff values. Volume Flow Cutoff affects both the volume flow values reported via the outputs and the volume flow values used in other transmitter behavior (e.g., events defined on the volume flow). mAO Cutoff affects only flow values reported through mA Output. Configuration and Use Manual 35 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 Example: Cutoff interaction with mAO Cutoff lower than Volume Flow Cutoff Configuration: • mA Output Process Variable: Volume Flow Rate • Frequency Output Process Variable: Volume Flow Rate • AO Cutoff: 10 l/sec • Volume Flow Cutoff: 15 l/sec Result: If the volume flow rate drops below 15 l/sec, volume flow will be reported as 0, and 0 will be used in all internal processing. Example: Cutoff interaction with mAO Cutoff higher than Volume Flow Cutoff Configuration: • mA Output Process Variable: Volume Flow Rate • Frequency Output Process Variable: Volume Flow Rate • AO Cutoff: 15 l/sec • Volume Flow Cutoff: 10 l/sec Result: • If the volume flow rate drops below 15 l/sec but not below 10 l/sec: — The mA Output will report zero flow. — The Frequency Output will report the actual flow rate, and the actual flow rate will be used in all internal processing. • If the volume flow rate drops below 10 l/sec, both outputs will report zero flow, and 0 will be used in all internal processing. 4.4 Configure Gas Standard Volume (GSV) flow measurement The gas standard volume (GSV) flow measurement parameters control how gas standard volume flow is measured and reported. Restriction You cannot implement both liquid volume flow and gas standard volume flow at the same time. Choose one or the other. 4.4.1 Configure Volume Flow Type for gas applications Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Flow Type → Gas ProLink III Device Tools → Configuration → Process Measurement → Flow → Volume Flow Type → Gas Standard Volume Field communicator Device Settings → Process Configuration → Optional Setup → Gas Standard Volume Volume Flow Type controls whether liquid or gas standard volume flow measurement will be used. Restriction Gas standard volume measurement is incompatible with the following applications: 36 Emerson.com Configuration and Use Manual MS-00809-0200-1600 • API Referral • Concentration measurement • Advanced Phase Measurement — liquid with gas Configure process measurement May 2024 For these applications, set Volume Flow Type to Liquid. Procedure Set Volume Flow Type to Gas. 4.4.2 Configure Standard Gas Density Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Standard Gas Density ProLink III Device Tools → Configuration → Process Measurement → Flow → Standard Density of Gas Field communicator Device Settings → Process Configuration → Optional Setup → Gas Standard Volume Standard Gas Density is the density of your gas at reference temperature and reference pressure. This is often called standard density or base density. It is used to calculate the GSV flow rate from the mass flow rate. Procedure Set Standard Gas Density to the density of your gas at reference temperature and reference pressure. You can use any reference temperature and reference pressure that you choose. It is not necessary to configure these values in the transmitter. Tip ProLink III provides a guided method that you can use to calculate the standard density of your gas if you do not know it. 4.4.3 Configure Gas Standard Volume Flow Measurement Unit Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Units ProLink III Device Tools → Configuration → Process Measurement → Flow → Gas Standard Volume Flow Unit Field communicator Device Settings → Process Configuration → Optional Setup → Gas Standard Volume Gas Standard Volume Flow Measurement Unit specifies the unit of measure that will be used for the gas standard volume (GSV) flow rate. The unit used for gas standard volume total and gas standard volume inventory is derived from this unit. Prerequisites Before you configure Gas Standard Volume Flow Measurement Unit, be sure that Volume Flow Type is set to Gas Standard Volume. Procedure Set Gas Standard Volume Flow Measurement Unit to the unit you want to use. Default: SCFM (Standard Cubic Feet per Minute) Tip If the measurement unit you want to use is not available, you can define a special measurement unit. Navigate using the Display Device → Tools → Configuration → Process Measurement → Flow and click the Gas Wizard button. Configuration and Use Manual 37 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 Options for Gas Standard Volume Flow Measurement Unit The transmitter provides a standard set of measurement units for Gas Standard Volume Flow Measurement Unit, plus one user-defined special measurement unit. Different communications tools may use different labels for the units. Label Unit description Display ProLink III Field communicator Normal cubic meters per second NCMS Nm3/sec Nm3/sec Normal cubic meters per minute NCMM Nm3/min Nm3/min Normal cubic meters per hour NCMH Nm3/hr Nm3/hr Normal cubic meters per day NCMD Nm3/day Nm3/day Normal liter per second NLPS NLPS NLPS Normal liter per minute NLPM NLPM NLPM Normal liter per hour NLPH NLPH NLPH Normal liter per day NLPD NLPD NLPD Standard cubic feet per second SCFS SCFS SCFS Standard cubic feet per minute SCFM SCFM SCFM Standard cubic feet per hour SCFH SCFH SCFH Standard cubic feet per day SCFD SCFD SCFD Standard cubic meters per second SCMS Sm3/sec Sm3/sec Standard cubic meters per minute SCMM Sm3/min Sm3/min Standard cubic meters per hour SCMH Sm3/hr Sm3/hr Standard cubic meters per day SCMD Sm3/day Sm3/day Standard liter per second SLPS SLPS SLPS Standard liter per minute SLPM SLPM SLPM Standard liter per hour SLPH SLPH SLPH Standard liter per day SLPD SLPD SLPD Special measurement unit SPECIAL Special Special Define a special measurement unit for gas standard volume flow Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Units → SPECIAL ProLink III Device Tools → Configuration → Process Measurement → Flow → Gas Standard Volume Flow Unit → Special Field communicator Device Settings → Process Configuration → Optional Setup → Gas Standard Volume 38 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 A special measurement unit is a user-defined unit of measure that allows you to report process data, totalizer data, and inventory data in a unit that is not available in the transmitter. A special measurement unit is calculated from an existing measurement unit using a conversion factor. Procedure 1. Specify Base Gas Standard Volume Unit. Base Gas Standard Volume Unit is the existing gas standard volume unit that the special unit will be based on. 2. Specify Base Time Unit. Base Time Unit is the existing time unit that the special unit will be based on. 3. Calculate Gas Standard Volume Flow Conversion Factor as follows: a) x base units = y special units b) Gas Standard Volume Flow Conversion Factor = x ÷ y 4. Enter the Gas Standard Volume Flow Conversion Factor. The original gas standard volume flow value is divided by this conversion factor. 5. Set Gas Standard Volume Flow Label to the name you want to use for the gas standard volume flow unit. 6. Set Gas Standard Volume Total Label to the name you want to use for the gas standard volume total and gas standard volume inventory unit. The special measurement unit is stored in the transmitter. You can configure the transmitter to use the special measurement unit at any time. Example: Defining a special measurement unit for gas standard volume flow You want to measure gas standard volume flow in thousands of standard cubic feet per minute. 1. Set Base Gas Standard Volume Unit to SCFM. 2. Set Base Time Unit to minutes (min). 3. Calculate the conversion factor: a. One thousands of standard cubic feet per minute = 1000 cubic feet per minute b. Gas Standard Volume Flow Conversion Factor = 1 ÷ 1000 = 0.001 4. Set Gas Standard Volume Flow Conversion Factor to 0.001. 5. Set Gas Standard Volume Flow Label to KSCFM. 6. Set Gas Standard Volume Total Label to KSCF. 4.4.4 Configure Gas Standard Volume Flow Cutoff Display Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Low Flow Cutoff ProLink III Device Tools → Configuration → Process Measurement → Flow → Gas Standard Volume Flow Cutoff Field communicator Device Settings → Process Configuration → Optional Setup → Gas Standard Volume Configuration and Use Manual 39 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 Gas Standard Volume Flow Cutoff specifies the lowest gas standard volume flow rate that will reported as measured. All gas standard volume flow rates below this cutoff will be reported as 0. Procedure Set Gas Standard Volume Flow Cutoff to the value you want to use. • Default: 0.0 • Range: 0.0 to any positive value Interaction between Gas Standard Volume Flow Cutoff and mA Output Cutoff Gas Standard Volume Flow Cutoff defines the lowest Gas Standard Volume flow value that the transmitter will report as measured. mA Output Cutoff defines the lowest flow rate that will be reported through mA Output. If mA Output Process Variable is set to Gas Standard Volume Flow Rate, the volume flow rate reported through mA Output is controlled by the higher of the two cutoff values. Gas Standard Volume Flow Cutoff affects both the gas standard volume flow values reported through outputs and the gas standard volume flow values used in other transmitter behavior (for example, events defined on gas standard volume flow). mA Output Cutoff affects only flow values reported through mA Output. Example: Cutoff interaction with mA Output Cutoff lower than Gas Standard Volume Flow Cutoff Configuration: • mA Output Process Variable for the primary mA Output: Gas Standard Volume Flow Rate • Frequency Output Process Variable: Gas Standard Volume Flow Rate • mA Output Cutoff for the primary mA Output: 10 SLPM (standard liters per minute) • Gas Standard Volume Flow Cutoff: 15 SLPM Result: If the Gas Standard Volume Flow Rate drops below 15 SLPM, the volume flow will be reported as 0, and 0 will be used in all internal processing. Example: Cutoff interaction with mA Output Cutoff higher than Gas Standard Volume Flow Cutoff Configuration: • mA Output Process Variable for the primary mA Output: Gas Standard Volume Flow Rate • Frequency Output Process Variable: Gas Standard Volume Flow Rate • mA Output Cutoff for the primary mA Output: 15 SLPM (standard liters per minute) • Gas Standard Volume Flow Cutoff: 10 SLPM Result: • If the Gas Standard Volume Flow Rate drops below 15 SLPM but not below 10 SLPM: — The primary mA Output will report zero flow. — The Frequency Output will report the actual flow rate, and the actual flow rate will be used in all internal processing. • 40 If the Gas Standard Volume Flow Rate drops below 10 SLPM, both outputs will report zero flow, and 0 will be used in all internal processing. Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 4.5 Configure density measurement The density measurement parameters control how density is measured and reported. Density measurement is used with mass flow rate measurement to determine liquid volume flow rate. 4.5.1 Configure Density Measurement Unit Display Menu → Configuration → Process Measurement → Density → Units ProLink III Device Tools → Configuration → Process Measurement → Density → Density Unit Field communicator Device Settings → Process Configuration → Density → Density Unit Density Measurement Unit controls the measurement units that will be used in density calculations and reporting. Restriction If the API Referral application is enabled, you cannot change the density measurement unit here. The density measurement unit is controlled by the API table selection. Procedure Set Density Measurement Unit to the option you want to use. Default: g/cm3 (grams per cubic centimeter) Options for Density Measurement Unit The transmitter provides a standard set of measurement units for Density Measurement Unit. Different communications tools may use different labels. Unit description Label Display ProLink III Field communicator Specific gravity(1) SGU SGU SGU Grams per cubic centimeter g/cm3 g/cm3 g/Cucm Grams per liter g/L g/l g/L Grams per milliliter g/mL g/ml g/mL Kilograms per liter kg/L kg/l kg/L Kilograms per cubic meter kg/m3 kg/m3 kg/Cum Pounds per U.S. gallon lb/gal lbs/USgal lb/gal Pounds per cubic foot lb/ft3 lbs/ft3 lb/Cuft Pounds per cubic inch lb/in3 lbs/in3 lb/CuIn Degrees API(2) API API degAPI Short ton per cubic yard STon/yd3 sT/yd3 STon/Cuyd (1) Non-standard calculation. This value represents line density divided by the density of water at 60 °F (15.6 °C). (2) Non standard calculation, unless the API referral application is enabled. Calculated from line density instead of specific gravity. Configuration and Use Manual 41 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 4.5.2 Configure Density Damping Display Menu → Configuration → Process Measurement → Density → Damping ProLink III Device Tools → Configuration → Process Measurement → Density → Density Damping Field communicator Device Settings → Process Configuration → Density → Density Damping Density Damping controls the amount of damping that will be applied to density data. Damping is used to smooth out small, rapid fluctuations in process measurement. The damping value specifies the time period, in seconds, over which the transmitter will spread changes in the process variable. At the end of the interval, the internal value of the process variable (the damped value) will reflect 63% of the change in the actual measured value. Procedure Set Density Damping to the desired value. • Default: 1.28 seconds • Range: 0.0 to 60 seconds Tip • A high damping value makes the process variable appear smoother because the reported value changes slowly. • A low damping value makes the process variable appear more erratic because the reported value changes more quickly. • The combination of a high damping value and rapid, large changes in density can result in increased measurement error. • Whenever the damping value is non-zero, the damped value will lag the actual measurement because the damped value is being averaged over time. • In general, lower damping values are preferable because there is less chance of data loss, and less lag time between the actual measurement and the damped value. • If a number greater than 60 is entered, it is automatically changed to 60. Effect of Density Damping on volume measurement Density Damping affects liquid volume measurement. Liquid volume values are calculated from the damped density value rather than the measured density value. Density Damping does not affect gas standard volume measurement. Interaction between Density Damping and mA Output Damping When mA Output is configured to report density, both Density Damping and mA Output Damping are applied to the reported density value. Density Damping controls the rate of change in the value of the process variable in transmitter memory. mA Output Damping controls the rate of change reported through mA Output. If mA Output Source is set to Density, and both Density Damping and mA Output Damping are set to non-zero values, density damping is applied first, and the mA Output damping calculation is applied to the result of the first calculation. This value is reported over mA Output. 4.5.3 Configure Density Cutoff Display 42 Menu → Configuration → Process Measurement → Density → Cutoff Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 ProLink III Device Tools → Configuration → Process Measurement → Density → Density Cutoff Field communicator Device Settings → Process Configuration → Density → Density Cutoff Density Cutoff specifies the lowest density value that will be reported as measured. All density values below this cutoff will be reported as 0. Procedure Set Density Cutoff to the value you want to use. • Default: 0.2 g/cm3 • Range: 0.0 g/cm3 to 0.5 g/cm3 Effect of Density Cutoff on volume measurement Density Cutoff affects liquid volume measurement. If the density value goes below Density Cutoff, the volume flow rate is reported as 0. 4.6 Configure temperature measurement The temperature measurement parameters control how temperature data is processed. Temperature data is used in several different ways, including temperature compensation, API Referral, and concentration measurement. 4.6.1 Configure Temperature Measurement Unit Display Menu → Configuration → Process Measurement → Temperature → Units ProLink III Device Tools → Configuration → Process Measurement → Temperature → Temperature Unit Field communicator Device Settings → Process Configuration → Temperature → Temperature Unit Temperature Measurement Unit specifies the unit that will be used for temperature measurement. Procedure Set Temperature Measurement Unit to the option you want to use. Default: °C (Celsius) Options for Temperature Measurement Unit The transmitter provides a standard set of units for Temperature Measurement Unit. Different communications tools may use different labels for the units. Unit description Label Display ProLink III Field communicator Degrees Celsius °C °C degC Degrees Fahrenheit °F °F degF Degrees Rankine °R °R degR Kelvin °K °K Kelvin Configuration and Use Manual 43 Configure process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 4.6.2 Configure Temperature Damping Display Menu → Configuration → Process Measurement → Temperature → Damping ProLink III Device Tools → Configuration → Process Measurement → Temperature → Temperature Damping Field communicator Device Settings → Process Configuration → Temperature → Temperature Unit Temperature Damping controls the amount of damping that will be applied to temperature data from the sensor. Temperature Damping is not applied to external temperature data. Damping is used to smooth out small, rapid fluctuations in process measurement. The damping value specifies the time period, in seconds, over which the transmitter will spread changes in the process variable. At the end of the interval, the internal value of the process variable (the damped value) will reflect 63% of the change in the actual measured value. Procedure Set Temperature Damping to the desired value. • Default: 4.8 seconds • Range: 0.0 to 80 seconds Note If a number greater than 80 is entered, it is automatically changed to 80. Tip • A high damping value makes the process variable appear smoother because the reported value changes slowly. • A low damping value makes the process variable appear more erratic because the reported value changes more quickly. • The combination of a high damping value and rapid, large changes in temperature can result in increased measurement error. • Whenever the damping value is non-zero, the damped value will lag the actual measurement because the damped value is being averaged over time. • In general, lower damping values are preferable because there is less chance of data loss, and less lag time between the actual measurement and the damped value. Effect of Temperature Damping on process measurement Temperature Damping affects all processes and algorithms that use temperature data from the internal sensor RTD. Temperature compensation Temperature compensation adjusts process measurement to compensate for the effect of temperature on the sensor tubes. API Referral Temperature Damping affects API Referral process variables only if the transmitter is configured to use temperature data from the sensor. If an external temperature value is used for API Referral, Temperature Damping does not affect API Referral process variables. Concentration measurement Temperature Damping affects concentration measurement process variables only if the transmitter is configured to use temperature data from the sensor. If an external temperature value is used for 44 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement May 2024 concentration measurement, Temperature Damping does not affect concentration measurement process variables. 4.7 Configure Pressure Measurement Unit Display Menu → Configuration → Process Measurement → Pressure → Units ProLink III Device Tools → Configuration → Process Measurement → Pressure Compensation → Pressure Unit Field communicator Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature Pressure Measurement Unit controls the measurement unit used for pressure. This unit must match the unit used by the external pressure device. Pressure data is used for pressure compensation and for API Referral. The device does not measure pressure directly. You must set up a pressure input. Procedure Set Pressure Measurement Unit to the desired unit. Default: psi 4.7.1 Options for Pressure Measurement Unit The transmitter provides a standard set of measurement units for Pressure Measurement Unit. Different communications tools may use different labels for the units. In most applications, set Pressure Measurement Unit to match the pressure measurement unit used by the remote device. Unit description Label Display ProLink III Field communicator Feet water @ 68 °F ftH2O @68°F Ft Water @ 68°F ftH₂O Inches water @ 4 °C inH2O @4°C In Water @ 4°C inH₂O @4DegC Inches water @ 60 °F inH2O @60°F In Water @ 60°F inH₂O @60DegF Inches water @ 68 °F inH2O @68°F In Water @ 68°F inH₂O Millimeters water @ 4 °C mmH2O @4°C mm Water @ 4°C mmH₂O @4DegC Millimeters water @ 68 °F mmH2O @68°F mm Water @ 68°F mmH₂O Millimeters mercury @ 0 °C mmHg @0°C mm Mercury @ 0°C mmHg Inches mercury @ 0 °C inHg @0°C In Mercury @ 0°C inHg Pounds per square inch psi PSI psi Bar bar bar bar Millibar mbar millibar mbar Grams per square centimeter g/cm2 g/cm2 g/Sqcm Kilograms per square centimeter kg/cm2 kg/cm2 kg/Sqcm Pascals Pa pascals Pa Kilopascals kPA Kilopascals kPa Megapascals mPA Megapascals MPa Torr @ 0 °C torr Torr @ 0°C torr Configuration and Use Manual 45 Configure process measurement May 2024 Unit description Atmospheres Configuration and Use Manual MS-00809-0200-1600 Label Display ProLink III Field communicator atm atms atm 4.8 Configure Velocity Measurement Unit Display Menu → Configuration → Process Measurement → Velocity → Units ProLink III Device Tools → Configuration → Process Measurement → Velocity → Unit Field communicator Device Settings → Process Configuration → Optional Setup → Velocity → Velocity Unit Velocity Measurement Unit controls the measurement unit used to report velocity. Procedure Set Velocity Measurement Unit to the desired unit. Default: m/sec 4.8.1 Options for Velocity Measurement Unit The transmitter provides a standard set of measurement units for Velocity Measurement Unit. Different communications tools may use different labels. Unit description Label Display ProLink III Field communicator Feet per minute ft/min ft/min ft/min Feet per second ft/s ft/sec ft/s Inches per minute in/min in/min in/min Inches per second in/s in/sec in/s Meters per hour m/h m/hr m/h Meters per second m/s m/sec m/s 46 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 5 Configure process measurement applications 5.1 Set up the API Referral application The API Referral application corrects line density to reference temperature and reference pressure according to American Petroleum Institute (API) standards. The resulting process variable is referred density. Restriction The API Referral application is not compatible with the following applications: • Gas Standard Volume Measurement (GSV) • Advanced Phase Measurement • Concentration measurement 5.1.1 Set up the API Referral application using the display Enable the API Referral application using the display The API Referral application must be enabled before you can perform any setup. If the API Referral application was enabled at the factory, you do not need to enable it now. Prerequisites The API Referral application must be licensed on your transmitter. Procedure 1. Choose Menu → Configuration → Process Measurement. 2. Choose Flow Variables → Volume Flow Settings and ensure that Flow Type is set to Liquid. 3. Return to the Process Measurement menu. 4. If the concentration measurement application is displayed in the list, choose Concentration Measurement and ensure that Enabled/Disabled is set to Disabled. The concentration measurement application and the API Referral application cannot be enabled simultaneously. 5. Enable API Referral. a) Choose Menu → Configuration → Process Measurement → API Referral. b) Set Enabled/Disabled to Enabled. Configure API Referral using the display The API Referral parameters specify the API table, measurement units, and reference values to be used in referred density calculations. Prerequisites You will need API documentation for the API table that you select. Depending on your API table, you may need to know the thermal expansion coefficient (TEC) for your process fluid. Configuration and Use Manual 47 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 You must know the reference temperature and reference pressure that you want to use. Procedure 1. Choose Menu → Configure → Process Measurement → API Referral. 2. Set API Table to the API table that you want to use to calculate referred density. Each API table is associated with a specific set of equations. Choose your API table based on your process fluid and the measurement unit that you want to use for referred density. Your choice also determines the API table that will be used to calculate the correction factor for volume (CTPL or CTL). 3. Refer to the API documentation and confirm your table selection. a) Verify that your process fluid falls within range for line density, line temperature, and line pressure. b) Verify that the referred density range of the selected table is adequate for your application. 4. If you chose a C table, enter Thermal Expansion Coefficient (TEC) for your process fluid. Acceptable limits: • 230.0 x 10-6 to 930.0 x 10-6 per °F • 414.0 x 10-6 to 1674.0 x 10-6 per °C 5. If required, set Reference Temperature to the temperature to which density will be corrected in referred density calculations. The default reference temperature is determined by the selected API table. 6. If required, set Reference Pressure to the pressure to which density will be corrected in referred density calculations. The default reference pressure is determined by the selected API table. Set up temperature and pressure data for API Referral using the display The API Referral application uses temperature and, optionally, pressure data in its calculations. You must decide how to provide this data, then perform the required configuration and setup. Note Fixed values for temperature or pressure are not recommended. Using a fixed temperature or pressure value may produce inaccurate process data. Prerequisites If you plan to poll an external device, the primary mA Output (Channel A) must be wired to support HART® communications. The pressure measurement must be gauge pressure, not atmospheric pressure. The pressure device must use the pressure unit that is configured in the transmitter. If you are using an external temperature device, it must use the temperature unit that is configured in the transmitter. Procedure 1. Choose the method to be used to supply temperature data, and perform the required setup. 48 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Method Description Internal temperature Temperature data from the on-board temperature sensor (RTD) will be used for all measurements and calculations. No external temperature data will be available. Polling The meter polls an external device for temperature data. This data will be available in addition to the internal temperature data. Configure process measurement applications May 2024 Setup a. Choose Menu → Configuration → Process Measurement → Temperature. b. Set External Temperature to Off. a. Choose Menu → Configuration → Process Measurement → Temperature. b. Set External Temperature to On. c. Choose Poll External Device. d. Select Polled Variable 1 or Polled Variable 2. e. Set Variable to External Temperature. f. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other HART® masters will be on the network. A field communicator is not a HART master. Poll as Secondary Other HART masters will be on the network. A field communicator is not a HART master. g. Set External Device Tag to the HART tag of the external temperature device. Digital communications A host writes temperature data to the meter at appropriate intervals. This data will be available in addition to the internal temperature data. a. Choose Menu → Configuration → Process Measurement → Temperature. b. Set External Temperature to On. c. Perform the necessary host programming and communications setup to write temperature data to the transmitter at appropriate intervals. 2. Choose the method to be used to supply pressure data, and perform the required setup. Configuration and Use Manual 49 Configure process measurement applications May 2024 Method Description Polling The meter polls an external device for pressure data. Configuration and Use Manual MS-00809-0200-1600 Setup a. Choose Menu → Configuration → Process Measurement → Pressure → External Pressure. b. Set External Pressure to On. c. Choose Poll External Device. d. Select Polled Variable 1 or Polled Variable 2. e. Set Variable to External Pressure. f. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other HART® masters will be on the network. A field communicator is not a HART master. Poll as Secondary Other HART masters will be on the network. A field communicator is not a HART master. g. Set External Device Tag to the HART tag of the external pressure device. Digital communications A host writes pressure data to the meter at appropriate intervals. a. Choose Menu → Configuration → Process Measurement → Pressure → External Pressure. b. Set External Pressure to On. c. Perform the necessary host programming and communications setup to write pressure data to the transmitter at appropriate intervals. Postrequisites Choose Menu → Service Tools → Service Data → View Process Variables and verify the values for External Temperature and External Pressure. Need help? If the value is not correct: • Ensure that the external device and the meter are using the same measurement unit. • For polling: — Verify the wiring between the meter and the external device. — Verify the HART® tag of the external device. 5.1.2 Set up the API Referral application using ProLink III Enable the API Referral application using ProLink III Prerequisites The API Referral application must be licensed and enabled on your transmitter before you can perform any setup. If the API Referral application was enabled at the factory, you do not need to enable it now. Procedure 1. Choose Device Tools → Configuration → Process Measurement → Flow and ensure that Volume Flow Type is set to Liquid Volume. 50 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 2. Choose Device Tools → Configuration → Transmitter Options. 3. If the concentration measurement application is enabled, disable it and select Apply. The concentration measurement application and the API Referral application cannot be enabled simultaneously. 4. Enable API Referral and select Apply. Configure API Referral using ProLink III The API Referral parameters specify the API table, measurement units, and reference values to be used in referred density calculations. Prerequisites You will need API documentation for the API table that you select. Depending on your API table, you may need to know the thermal expansion coefficient (TEC) for your process fluid. You must know the reference temperature and reference pressure that you want to use. Procedure 1. Choose Device Tools → Configuration → Process Measurement → API Referral. 2. Specify the API table to use to calculate referred density. Each API table is associated with a specific set of equations. a) Set Process Fluid to the API table group that your process fluid belongs to. API table group Process fluids A tables Generalized crude and JP4 B tables Generalized products: Gasoline, jet fuel, aviation fuel, kerosene, heating oils, fuel oils, diesel, gas oil C tables Liquids with a constant base density or known thermal expansion coefficient (TEC). You will be required to enter the TEC for your process fluid. D tables Lubricating oils E tables NGL (Natural Gas Liquids) and LPG (Liquid Petroleum Gas) b) Set Referred Density Measurement Unit to the measurement units that you want to use for referred density. c) Select Apply. These parameters uniquely identify the API table to be used to calculate referred density. The selected API table is displayed, and the meter automatically changes the density unit, temperature unit, pressure unit, and reference pressure to match the API table. Your choice also determines the API table that will be used to calculate the correction factor for volume (CTPL or CTL). Restriction Not all combinations are supported by the API Referral application. See the list of API tables in this manual. 3. Refer to the API documentation and confirm your table selection. a) Verify that your process fluid falls within range for line density, line temperature, and line pressure. Configuration and Use Manual 51 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 b) Verify that the referred density range of the selected table is adequate for your application. 4. If you chose a C table, enter Thermal Expansion Coefficient (TEC) for your process fluid. Acceptable limits: • 230.0 x 10-6 to 930.0 x 10-6 per °F • 414.0 x 10-6 to 1674.0 x 10-6 per °C 5. Set Reference Temperature to the temperature to which density will be corrected in referred density calculations. If you choose Other, select the temperature measurement unit and enter the reference temperature. 6. Set Reference Pressure to the pressure to which density will be corrected in referred density calculations. Set up temperature and pressure data for API Referral using ProLink III The API Referral application uses temperature and, optionally, pressure data in its calculations. You must decide how to provide this data, then perform the required configuration and setup. Note Fixed values for temperature or pressure are not recommended. Using a fixed temperature or pressure value may produce inaccurate process data. Prerequisites If you plan to poll an external device, the primary mA Output (Channel A) must be wired to support HART® communications. The pressure measurement must be gauge pressure, not atmospheric pressure. The pressure device must use the pressure unit that is configured in the transmitter. If you are using an external temperature device, it must use the temperature unit that is configured in the transmitter. Procedure 1. Choose Device Tools → Configuration → Process Measurement → API Referral. 2. Choose the method to be used to supply temperature data, and perform the required setup. Option Description Polling The meter polls an external device for temperature data. This data will be available in addition to the internal RTD temperature data. Setup a. Set Line Temperature Source to Poll for External Value. b. Set Polling Slot to an available slot. c. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other HART® masters will be on the network. A field communicator is not a HART master. Poll as Secondary Other HART masters will be on the network. A field communicator is not a HART master. d. Set External Device Tag to the HART tag of the temperature device. e. Select Apply. 52 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Option Description Digital communications A host writes temperature data to the meter at appropriate intervals. This data will be available in addition to the internal RTD temperature data. Configure process measurement applications May 2024 Setup a. Set Line Temperature Source to Fixed Value or Digital Communications. b. Select Apply. c. Perform the necessary host programming and communications setup to write temperature data to the meter at appropriate intervals. 3. Choose the method you will use to supply pressure data, and perform the required setup. Option Description Polling The meter polls an external device for pressure data. Setup a. Set Pressure Source to Poll for External Value. b. Set Polling Slot to an available slot. c. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other HART masters will be on the network. A field communicator is not a HART master. Poll as Secondary Other HART masters will be on the network. A field communicator is not a HART master. d. Set External Device Tag to the HART tag of the temperature device. Digital communications A host writes pressure data to the meter at appropriate intervals. a. Set Pressure Source to Fixed Value or Digital Communications. b. Perform the necessary host programming and communications setup to write pressure data to the meter at appropriate intervals. Postrequisites If you are using external temperature data, verify the external temperature value displayed in the Inputs group on the ProLink III main window. The current pressure value is displayed in the External Pressure field. Verify that the value is correct. Need help? If the value is not correct: • Ensure that the external device and the meter are using the same measurement unit. • For polling: — Verify the wiring between the meter and the external device. — Verify the HART® tag of the external device. Configuration and Use Manual 53 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 5.1.3 Set up the API Referral application using a field communicator Enable the API Referral application using a field communicator Prerequisites The API Referral application must be licensed and enabled on your transmitter. If the API Referral application was enabled at the factory, you do not need to enable it now. Volume Flow Type must be set to Liquid. Procedure 1. Choose Device Settings → Device Information → Licenses → Enable/Disable Applications → Volume Flow Type and ensure that Volume Flow Type is set to Liquid. This parameter is available only if API Referral or concentration measurement is not enabled. If you do not see this parameter, it is already set correctly. 2. If the concentration measurement application is enabled, disable it. The concentration measurement application and the API Referral application cannot be enabled simultaneously. 3. Enable the API Referral application. 4. If Device Settings → Device Information → Licenses → Enable/Disable Applications → Advanced Phase Measurement → Output Type is other than Disabled, disable it. The Advance Phase Measurement application and the API Referral application cannot be enabled simultaneously. Configure API Referral using a field communicator The API Referral parameters specify the API table, measurement units, and reference values to be used in referred density calculations. Prerequisites You will need API documentation for the API table that you select. Depending on your API table, you may need to know the thermal expansion coefficient (TEC) for your process fluid. You must know the reference temperature and reference pressure that you want to use. Procedure 1. Choose Device Settings → Process Configuration → Optional Setup → API Referral. 2. Choose API Referral Setup. 3. Specify the API table that you want to use to calculate referred density. Each API table is associated with a specific set of equations. a) Set API Table Number to the number that matches the API table units that you want to use for referred density. Your choice also determines the measurement unit to be used for temperature and pressure, and the default values for reference temperature and reference pressure. API table number Measurement unit for referred density Temperature measurement unit Pressure measurement unit Default reference Default reference temperature pressure 5 °API °F psi (g) 60 °F 54 0 psi (g) Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 API table number Measurement unit for referred density Temperature measurement unit Pressure measurement unit Default reference Default reference temperature pressure 6(1) °API °F psi (g) 60 °F 0 psi (g) 23 SGU °F psi (g) 60 °F 0 psi (g) 24(1) SGU °F psi (g) 60 °F 0 psi (g) 53 kg/m³ °C kPa (g) 15 °C 0 kPa (g) 54(1) kg/m³ °C kPa (g) 15 °C 0 kPa (g) 59(2) kg/m³ °C kPa (g) 20 °C 0 kPa (g) 60(2) kg/m³ °C kPa (g) 20 °C 0 kPa (g) (1) Used only with API Table Letter = C. (2) Used only with API Table Letter = E. b) Set API Table Letter to the letter of the API table group that is appropriate for your process fluid. API table letter Process fluids A Generalized crude and JP4 B Generalized products: Gasoline, jet fuel, aviation fuel, kerosene, heating oils, fuel oils, diesel, gas oil C(1) Liquids with a constant base density or known thermal expansion coefficient (TEC). You will be required to enter the TEC for your process fluid. D Lubricating oils E(2) NGL (Natural Gas Liquids) and LPG (Liquid Petroleum Gas) (1) Used only with API Table Number = 6, 24, or 54. (2) Used only with API Table Number = 23, 24, 53, 54, 59, or 60. API Table Number and API Table Letter uniquely identify the API table. The selected API table is displayed, and the meter automatically changes the density unit, temperature unit, pressure unit, reference temperature, and reference pressure to match the API table. Your choice also determines the API table that will be used to calculate the correction factor for volume (CTPL or CTL). Restriction Not all combinations are supported by the API Referral application. See the list of API tables in this manual. 4. If you chose a C table, enter Thermal Expansion Coefficient (TEC) for your process fluid. Acceptable limits: • 230.0 x 10-6 to 930.0 x 10-6 per °F • 414.0 x 10-6 to 1674.0 x 10-6 per °C 5. Refer to the API documentation and confirm your table selection. a) Verify that your process fluid falls within range for line density, line temperature, and line pressure. b) Verify that the referred density range of the selected table is adequate for your application. Configuration and Use Manual 55 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 6. If required, set Reference Temperature to the temperature to which density will be corrected in referred density calculations. The default reference temperature is determined by the selected API table. 7. If required, set Reference Pressure to the pressure to which density will be corrected in referred density calculations. The default reference pressure is determined by the selected API table. API Referral requires gauge pressure. Set up temperature and pressure data for API Referral using a field communicator The API Referral application uses temperature and, optionally, pressure data in its calculations. You must decide how to provide this data, then perform the required configuration and setup. Note Fixed values for temperature or pressure are not recommended. Using a fixed temperature or pressure value may produce inaccurate process data. Procedure 1. Choose the method to be used to supply temperature data, and perform the required setup. Method Description Internal RTD temperature data Temperature data from the on-board temperature sensor (RTD) is used. Polling The meter polls an external device for temperature data. This data will be available in addition to the internal RTD temperature data. Setup a. Choose Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → Temperature. b. Set External Temperature to Disable. a. Choose Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → Temperature. b. Set External Temperature to Enable. c. Choose Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → External Polling. d. Set Poll Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other Primary HART masters will be on the network. A field communicator is not a HART master. Poll as Secondary No other Secondary HART masters will be on the network. A field communicator is not a HART master. e. Choose an unused polling slot. f. Set External Device Tag to the HART tag of the external temperature device. g. Set Polled Variable to Temperature. 56 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Method Description Digital communications A host writes temperature data to the meter at appropriate intervals. This data will be available in addition to the internal RTD temperature data. Configure process measurement applications May 2024 Setup a. Choose Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → Temperature. b. Set Temperature Compensation to Enable. c. Perform the necessary host programming and communications setup to write temperature data to the meter at appropriate intervals. 2. Choose the method to be used to supply pressure data, and perform the required setup. Method Description Polling The meter polls an external device for pressure data. Setup a. Choose Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → Pressure. b. Set Pressure Compensation to Enable. c. Choose Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → External Polling. d. Choose an unused polling slot. e. Set Poll Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other Primary HART masters will be on the network. A field communicator is not a HART master. Poll as Secondary No other Secondary HART masters will be on the network. A field communicator is not a HART master. f. Set External Device Tag to the HART tag of the external pressure device. g. Set Polled Variable to Pressure. Digital communications A host writes pressure data to the meter at appropriate intervals. a. Choose Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → Pressure. b. Set Pressure Compensation to Enable. c. Perform the necessary host programming and communications setup to write pressure data to the transmitter at appropriate intervals. Postrequisites Need help? If the value is not correct: • Ensure that the external device and the meter are using the same measurement unit. • For polling: — Verify the wiring between the meter and the external device. — Verify the HART tag of the external device. Configuration and Use Manual 57 Configure process measurement applications May 2024 • Configuration and Use Manual MS-00809-0200-1600 For digital communications: — Verify that the host has access to the required data. — Verify that the host is writing to the correct register in memory, using the correct data type. 5.1.4 API tables supported by the API Referral application The API tables listed here are supported by the API Referral application. Table 5-1: API tables, process fluids, measurement units, and default reference values Process fluid Generalized crude and JP4 API tables (calculations)(1) Lubricating oils NGL (natural gas liquids) and LPG (liquid petroleum gas) Default reference temp Default reference pressure API standard API MPMS 11.1 Referred density(2) CTL or CTPL(3)(4) 5A 6A Unit: °API Range: 0 to 100 °API 60 °F 0 psi (g) 23A 24A Unit: SGU Range: 0.6110 to 1.0760 SGU 60 °F 0 psi (g) 53A 54A Unit: kg/m3 Range: 610 to 1075 kg/m³ 15 °C 0 kPa (g) 5B 6B Unit: °API Range: 0 to 85 °API 60 °F 0 psi (g) 24B Unit: SGU Range: 0.6535 to 1.0760 SGU 60 °F 0 psi (g) 54B Unit: kg/m3 Range: 653 to 1075 kg/m³ 15 °C 0 kPa (g) N/A 6C Unit: °API 60 °F 0 psi (g) N/A 24C Unit: SGU 60 °F 0 psi (g) N/A 54C Unit: kg/m³ 15 °C 0 kPa (g) 5D 6D Unit: °API Range: −10 to +40 °API 60 °F 0 psi (g) 23D 24D Unit: SGU Range: 0.8520 to 1.1640 SGU 60 °F 0 psi (g) 53D 54D Unit: kg/m³ Range: 825 to 1164 kg/m³ 15 °C 0 kPa (g) 23E 24E Unit: SGU 60 °F 0 psi (g) 53E 54E Unit: kg/m³ 15 °C 0 psi (g) 59E 60E Unit: kg/m³ 20 °C 0 psi (g) Generalized products 23B (gasoline, jet fuel, aviation fuel, kerosene, heating oils, fuel oils, diesel, 53B gas oil) Liquids with a constant density base or known thermal expansion coefficient(5) Referred density (API): unit and range API MPMS 11.1 API MPMS 11.1 API MPMS 11.1 API MPMS 11.2.4 (1) Each API table represents a specialized equation defined by the American Petroleum Institute for a specific combination of process fluid, line conditions, and output. 58 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 (2) Referred density is calculated from line density. You must specify this table, either directly or by selecting the process fluid and base density measurement unit. (3) You do not need to specify this table. It is invoked automatically as a result of the previous table selection. (4) CTL is a correction factor based on online temperature. CTPL is a correction factor based on both line pressure and line temperature. Calculation of CTL and CTPL for A, B, C, and D table products is in accordance with API MPMS Chapter 11.1. Calculation of CTL and CTPL for E table products is in accordance with API MPMS Chapters 11.2.2, 11.2.4, and 11.2.5. (5) The Thermal Expansion Coefficient (TEC) replaces the referred density calculation. Use the CTL/CTPL table instead. 5.1.5 Process variables from the API Referral application The API Referral application calculates several different process variables according to API standards. CTPL Correction factor based on line temperature and line pressure. CTL Correction factor based on line temperature at saturation conditions. Referred density The measured density after CTL or CTPL has been applied. API volume flow The measured volume flow rate after CTL or CTPL has been applied. Also called corrected volume flow. Batch-weighted average density One density value is recorded for each unit of flow (e.g., barrel, liter). The average is calculated from these values. The average is reset when the API totalizer is reset. Not available unless a totalizer has been configured with Source set to Corrected Volume Flow. Batch-weighted average temperature One temperature value is recorded for each unit of flow (e.g., barrel, liter). The average is calculated from these values. The average is reset when the API totalizer is reset. Not available unless a totalizer has been configured with Source set to TemperatureCorrected Volume Flow. API volume total The total API volume measured by the transmitter since the last API totalizer reset. Also called corrected volume total. Not available unless a totalizer has been configured with Source set to Corrected Volume Flow. API volume inventory The total API volume measured by the transmitter since the last API inventory reset. Also called corrected volume inventory. Not available unless an inventory has been configured with Source set to Corrected Volume Flow. 5.2 Set up concentration measurement The concentration measurement application calculates concentration from line density and line temperature. 5.2.1 Preparing to set up concentration measurement The procedure for setting up concentration measurement application depends on how your device was ordered and how you want to use the application. Review this information before you begin. Requirements for concentration measurement To use the concentration measurement application, the following conditions must be met: • The concentration measurement application must be enabled. • The API Referral application must be disabled. • The Advanced Phase Measurement application must be disabled or set for the Liquid with Gas application. • A concentration matrix must be loaded into one of the six slots on the transmitter. Configuration and Use Manual 59 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 Tip In most cases, the concentration matrix that you ordered was loaded at the factory. If it was not, you have several options for loading a matrix. You can also build a matrix. • Temperature Source must be configured and set up. • One matrix must be selected as the active matrix (the matrix used for measurement). Requirements for matrices A matrix is the set of coefficients used to convert process data to concentration, plus related parameters. The matrix can be saved as a file. The transmitter requires all matrices to be in .matrix format. You can use ProLink III to load matrices in other formats: • .xml (used by ProLink III) The transmitter can store matrices in one of the six slots in memory. Any matrix in a slot is available for use. In other words, it can be selected as the active matrix and used for measurement. Matrices must be loaded into a slot before they can be used for measurement. All matrices in slots must use the same derived variable. Requirements for derived variables A derived variable is the process variable that a concentration matrix measures. All other process variables are calculated from the derived variable. There are eight possible derived variables. Each matrix is designed for one specific derived variable. The transmitter can store up to six matrices in six slots. All matrices in the six slots must use the same derived variable. If you change the setting of Derived Variable, all matrices are deleted from the six slots. Tip Always ensure that Derived Variable is set correctly before loading matrices into slots. Derived variables and net flow rate If you want the transmitter to calculate Net Mass Flow Rate, the derived variable must be set to Mass Concentration (Density). If your matrix is not designed for Mass Concentration (Density), contact customer support for assistance. If you want the transmitter to calculate Net Volume Flow Rate, the derived variable must be set to Volume Concentration (Density). If your matrix is not designed for Volume Concentration (Density), contact customer support for assistance. Derived variables based on specific gravity The following derived variables are based on specific gravity: • Specific Gravity • Concentration (Specific Gravity) • Mass Concentration (Specific Gravity) • Volume Concentration (Specific Gravity) If you are using one of these derived variables, two additional parameters can be configured: • Reference Temperature of Water (default setting: 4 °C) • Water Density at Reference Temperature (default setting: 999.99988 kg/m³) These two parameters are used to calculate specific gravity. 60 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 You cannot set these parameters from the display. If the default values are not appropriate, you must use another method to set them. Optional tasks in setting up concentration measurement The following tasks are optional: • Modifying names and labels • Configuring extrapolation alerts 5.2.2 Set up concentration measurement using the display This section guides you through most of the tasks related to setting up and implementing the concentration measurement application. Restriction This section does not cover building a concentration matrix. For detailed information on building a matrix, see the Micro Motion Enhanced Density Application Manual. Enable concentration measurement using the display The concentration measurement application must be enabled before you can perform any setup. If the concentration measurement application was enabled at the factory, you do not need to enable it now. Prerequisites The concentration measurement application must be licensed on your transmitter. Disable the following applications before enabling concentration measurement as concentration measurement cannot be enabled at the same time: • Advanced Phase Measurement — gas with liquid • API Referral • Gas Standard Volume Procedure 1. Choose Menu → Configuration → Process Measurement. 2. Choose Flow Variables → Volume Flow Settings and ensure that Flow Type is set to Liquid. 3. Return to the Process Measurement menu. 4. If the API Referral application is displayed in the menu, choose API Referral and ensure that Enabled/ Disabled is set to Disabled. The concentration measurement application and the API Referral application cannot be enabled simultaneously. 5. If the Advanced Phase Measurement application is displayed in the menu, choose Advanced Phase Measurement → Application Setup and ensure that Enabled/Disabled is set to Disabled. 6. Enable concentration measurement. a) Choose Menu → Configuration → Process Measurement → Concentration Measurement. b) Set Enabled/Disabled to Enabled. Set up temperature data using the display The concentration measurement application uses line temperature data in its calculations. You must decide how to provide this data, then perform the required configuration and setup. Temperature data from the Configuration and Use Manual 61 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 on-board temperature sensor (RTD) is always available. Optionally, you can set up an external temperature device and use external temperature data. The temperature setup that you establish here will be used for all concentration measurement matrices on this meter. Important Line temperature data is used in several different measurements and calculations. It is possible to use the internal RTD temperature in some areas and an external temperature in others. The transmitter stores the internal RTD temperature and the external temperature separately. However, the transmitter stores only one alternate temperature value, which may be either the external temperature or the configured fixed value. Accordingly, if you choose a fixed temperature for some uses, and an external temperature for others, the external temperature will overwrite the fixed value. Procedure Choose the method to be used to supply temperature data, and perform the required setup. Method Description Internal temperature Temperature data from the on-board temperature sensor (RTD) will be used for all measurements and calculations. No external temperature data will be available. Polling The meter polls an external device for temperature data. This data will be available in addition to the internal temperature data. Setup a. Choose Menu → Configuration → Process Measurement → Temperature. b. Set External Temperature to Off. a. Choose Menu → Configuration → Process Measurement → Temperature. b. Set External Temperature to On. c. Choose Poll External Device. d. Select Polled Variable 1 or Polled Variable 2. e. Set Variable to External Temperature. f. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other HART masters will be on the network. A field communicator is not a HART master. Poll as Secondary Other HART masters will be on the network. A field communicator is not a HART master. g. Set External Device Tag to the HART tag of the external temperature device. Digital communications 62 A host writes temperature data to the meter at appropriate intervals. This data will be available in addition to the internal temperature data. a. Choose Menu → Configuration → Process Measurement → Temperature. b. Set External Temperature to On. c. Perform the necessary host programming and communications setup to write temperature data to the transmitter at appropriate intervals. Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 Postrequisites Choose Menu → Service Tools → Service Data → View Process Variables and verify the value for External Temperature. Need help? If the value is not correct: • Ensure that the external device and the meter are using the same measurement unit. • For polling: — Verify the wiring between the meter and the external device. — Verify the HART® tag of the external device. Modify matrix names and labels using the display For convenience, you can change the name of a concentration matrix and the label used for its measurement unit. This does not affect measurement. Procedure 1. Choose Menu → Configuration → Process Measurement → Concentration Measurement → Configure Matrix. 2. Select the matrix that you want to modify. 3. Set Matrix Name to the name that will be used for this matrix. 4. Set Concentration Unit to the label that will be used for the concentration unit. If you want to use a custom label, you can use the display to select Special. However, you cannot use the display to configure the custom label. You must use another tool to change the label from Special to a user-defined string. Modify extrapolation alerts using the display You can enable and disable extrapolation alerts, and set extrapolation alert limits. These parameters control the behavior of the concentration measurement application but do not affect measurement directly. Each concentration matrix is built for a specific density range and a specific temperature range. If line density or line temperature goes outside the range, the transmitter will extrapolate concentration values. However, extrapolation may affect accuracy. Extrapolation alerts are used to notify the operator that extrapolation is occurring. Each concentration matrix has its own extrapolation alert limits. Procedure 1. Choose Menu → Configuration → Process Measurement → Concentration Measurement → Configure Matrix. 2. Select the matrix that you want to modify. 3. Set Extrapolation Limit to the point, in percent, at which an extrapolation alert will be posted. 4. Choose Menu → Configuration → Process Measurement → Concentration Measurement → Configure Application → Extrapolation Alerts. 5. Enable or disable the high and low limit alerts for temperature and density as desired. Example: Extrapolation alerts in action If Extrapolation Limit is set to 5%, High Limit (Temp) is enabled, and the active matrix is built for a temperature range of 40 °F (4.4 °C) to 80 °F (26.7 °C), a high-temperature extrapolation alert will be posted if line temperature goes above 82 °F (27.8 °C). Configuration and Use Manual 63 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 Select the active concentration matrix using the display You must select the concentration matrix to be used for measurement. Although the transmitter can store up to six concentration matrices, only one matrix can be used for measurement at any one time. Procedure 1. Choose Menu → Configuration → Process Measurement → Concentration Measurement → Configure Application. 2. Set Active Matrix to the matrix you want to use. 5.2.3 Set up concentration measurement using ProLink III This section guides you through the tasks required to set up, configure, and implement concentration measurement. Enable concentration measurement using ProLink III The concentration measurement application must be enabled before you can perform any setup. If the concentration measurement application was enabled at the factory, you do not need to enable it now. Prerequisites The concentration measurement application must be licensed on your transmitter. Disable the following applications before enabling concentration measurement as concentration measurement cannot be enabled at the same time: • Advanced Phase Measurement — gas with liquid • API Referral • Gas Standard Volume Procedure 1. Choose Device Tools → Configuration → Process Measurement → Flow and ensure that Volume Flow Type is set to Liquid Volume. 2. Choose Device Tools → Configuration → Process Measurement → Advance Phase Measurement → APM Status and ensure that Application Status is set to Disable or Liquid with Gas. 3. Choose Device Tools → Configuration → Transmitter Options. 4. Disable API Referral and set the Advance Phase Measurement application to Disabled or Single Liquid. 5. Set Concentration Measurement to Enabled and select Apply. Load a concentration matrix using ProLink III At least one concentration matrix must be loaded onto your transmitter. You can load up to six. Prerequisites The concentration measurement application must be enabled on your device. For each concentration matrix that you want to load, you need a file containing the matrix data. The ProLink III installation includes a set of standard concentration matrices. Other matrices are available from Emerson. The file can be on your computer or in the transmitter internal memory. The file must be in one of the formats that ProLink III supports. This includes: • .xml (ProLink III) • .matrix (1600) 64 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 If you are loading an .xml file, you must know the following information for your matrix: • The derived variable that the matrix is designed to calculate • The density unit that the matrix was built with • The temperature unit that the matrix was built with If you are loading a .matrix file, you must know the derived variable that the matrix is designed to calculate. Important • All concentration matrices on your transmitter must use the same derived variable. • If you change the setting of Derived Variable, all existing concentration matrices will be deleted from the six slots on the transmitter. Set Derived Variable before loading concentration matrices. • ProLink III loads matrices directly to one of the six transmitter slots. Tip In many cases, concentration matrices were ordered with the device and loaded at the factory. You may not need to load any matrices. Procedure 1. If you are loading an .xml file, choose Device Tools → Configuration → Process Measurement → Line Density and set Density Unit to the density unit used by your matrix. Important When you load a matrix in one of these formats, if the density unit is not correct, concentration data will be incorrect. The density units must match at the time of loading. You can change the density unit after the matrix is loaded. 2. If you are loading an .xml file, choose Device Tools → Configuration → Process Measurement → Line Temperature and set Temperature Unit to the temperature unit used by your matrix. Important When you load a matrix in one of these formats, if the temperature unit is not correct, concentration data will be incorrect. The temperature units must match at the time of loading. You can change the temperature unit after the matrix is loaded. 3. Choose Device Tools → Configuration → Process Measurement → Concentration Measurement. The Concentration Measurement window is displayed. It is organized into steps that allow you to perform several different setup and configuration tasks. For this task, you will not use all the steps. 4. In Step 1, ensure that the setting of Derived Variable matches the derived variable used by your matrix. If it does not, change it as required and select Apply. Important If you change the setting of Derived Variable, all existing concentration matrices will be deleted from the six slots. Verify the setting of Derived Variable before continuing. 5. Load one or more matrices. a) In Step 2, set Matrix Being Configured to the location (slot) to which the matrix will be loaded. b) To load a .xml file from your computer, select Load Matrix from File, navigate to the file, and load it. c) To load a .matrix file from your computer, select Load Matrix from My Computer, navigate to the file, and load it. d) To load a .matrix file from the transmitter internal memory, select Load Matrix from 1600 Device Memory, navigate to the file on the transmitter, and load it. Configuration and Use Manual 65 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 e) Repeat until all required matrices are loaded. Set reference temperature values for specific gravity using ProLink III When Derived Variable is set to any option based on specific gravity, you must set the reference temperature for water, then verify the density of water at the configured reference temperature. These values affect specific gravity measurement. This requirement applies to the following derived variables: • Specific Gravity • Concentration (Specific Gravity) • Mass Concentration (Specific Gravity) • Volume Concentration (Specific Gravity) Procedure 1. Choose Device Tools → Configuration → Process Measurement → Concentration Measurement. The Concentration Measurement window is displayed. It is organized into steps that allow you to perform several different setup and configuration tasks. For this task, you will not use all the steps. 2. Scroll to Step 2, set Matrix Being Configured to the matrix you want to modify, and select Change Matrix. 3. Scroll to Step 3, then perform the following actions: a) Set Reference Temperature for Referred Density to the temperature to which line density will be corrected for use in the specific gravity calculation. b) Set Reference Temperature for Water to the water temperature that will be used in the specific gravity calculation. c) Set Water Density at Reference Temperature to the density of water at the specified reference temperature. The transmitter automatically calculates the density of water at the specified temperature. The new value will be displayed the next time that transmitter memory is read. You can enter a different value if you prefer. 4. Select Apply at the bottom of Step 3. Set up temperature data using ProLink III The concentration measurement application uses line temperature data in its calculations. You must decide how to provide this data, then perform the required configuration and setup. Temperature data from the on-board temperature sensor (RTD) is always available. Optionally, you can set up an external temperature device and use external temperature data. The temperature setup that you establish here will be used for all concentration measurement matrices on this meter. Important Line temperature data is used in several different measurements and calculations. It is possible to use the internal RTD temperature in some areas and an external temperature in others. The transmitter stores the internal RTD temperature and the external temperature separately. However, the transmitter stores only one alternate temperature value, which may be either the external temperature or the configured fixed value. Accordingly, if you choose a fixed temperature for some uses, and an external temperature for others, the external temperature will overwrite the fixed value. 66 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 Procedure 1. Choose Device Tools → Configuration → Process Measurement → Concentration Measurement. The Concentration Measurement window is displayed. It is organized into steps that allow you to perform several different setup and configuration tasks. For this task, you will not use all the steps. 2. Scroll to Step 4. 3. Choose the method to be used to supply temperature data, and perform the required setup. Option Description Internal temperature Temperature data from the on-board temperature sensor (RTD) will be used for all measurements and calculations. No external temperature data will be available. Polling The meter polls an external device for temperature data. This data will be available in addition to the internal RTD temperature data. Setup a. Set Line Temperature Source to Internal. b. Click Apply. a. Set Line Temperature Source to Poll for External Value. b. Set Polling Slot to an available slot. c. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other HART masters will be on the network. A field communicator is not a HART master. Poll as Secondary Other HART masters will be on the network. A field communicator is not a HART master. d. Set External Device Tag to the HART tag of the temperature device. e. Click Apply. Digital communications A host writes temperature data to the meter at appropriate intervals. This data will be available in addition to the internal RTD temperature data. a. Set Line Temperature Source to Fixed Value or Digital Communications. b. Click Apply. c. Perform the necessary host programming and communications setup to write temperature data to the meter at appropriate intervals. Postrequisites If you are using external temperature data, verify the external temperature value displayed in the Inputs group on the ProLink III main window. Need help? If the value is not correct: • Ensure that the external device and the meter are using the same measurement unit. • For polling: — Verify the wiring between the meter and the external device. — Verify the HART® tag of the external device. Configuration and Use Manual 67 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 Modify matrix names and labels using ProLink III For convenience, you can change the name of a concentration matrix and the label used for its measurement unit. This does not affect measurement. Procedure 1. Choose Device Tools → Configuration → Process Measurement → Concentration Measurement. The Concentration Measurement window is displayed. It is organized into steps that allow you to perform several different setup and configuration tasks. For this task, you will not use all the steps. 2. Scroll to Step 2, set Matrix Being Configured to the matrix you want to modify, and click Change Matrix. 3. Scroll to Step 3, then perform the following actions: a) Set Concentration Units Label to the label that will be used for the concentration unit. b) If you set Concentration Units Label to Special, enter the custom label in User-Defined Label. c) In Matrix Name, enter the name to be used for the matrix. 4. Select Apply at the bottom of Step 3. Modify extrapolation alerts using ProLink III You can enable and disable extrapolation alerts, and set extrapolation alert limits. These parameters control the behavior of the concentration measurement application but do not affect measurement directly. Each concentration matrix is built for a specific density range and a specific temperature range. If line density or line temperature goes outside the range, the transmitter will extrapolate concentration values. However, extrapolation may affect accuracy. Extrapolation alerts are used to notify the operator that extrapolation is occurring. Each concentration matrix has its own extrapolation alert limits. Procedure 1. Choose Device Tools → Configuration → Process Measurement → Concentration Measurement. The Concentration Measurement window is displayed. It is organized into steps that allow you to perform several different setup and configuration tasks. For this task, you will not use all the steps. 2. Scroll to Step 2, set Matrix Being Configured to the matrix you want to modify, and click Change Matrix. 3. Scroll to Step 4. 4. Set Extrapolation Alert Limit to the point, in percent, at which an extrapolation alert will be posted. 5. Enable or disable the high and low limit alerts for temperature and density, as desired, and click Apply. Example: Extrapolation alerts in action If Extrapolation Limit is set to 5%, High Limit (Temp) is enabled, and the active matrix is built for a temperature range of 40 °F (4.4 °C) to 80 °F (26.7 °C), a high-temperature extrapolation alert will be posted if line temperature goes above 82 °F (27.8 °C). Select the active concentration matrix using ProLink III You must select the concentration matrix to be used for measurement. Although the transmitter can store up to six concentration matrices, only one matrix can be used for measurement at any one time. Procedure 1. Choose Device Tools → Configuration → Process Measurement → Concentration Measurement. 2. Scroll to Step 2, set Active Matrix to the matrix you want to use and select Change Matrix. 68 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure process measurement applications May 2024 5.2.4 Set up concentration measurement using a field communicator This section guides you through most of the tasks related to setting up and implementing the concentration measurement application. Enable concentration measurement using a field communicator The concentration measurement application must be enabled before you can perform any setup. If the concentration measurement application was enabled at the factory, you do not need to enable it now. Prerequisites The concentration measurement application must be licensed on your transmitter. Disable the following applications before enabling concentration measurement as concentration measurement cannot be enabled at the same time: • Advanced Phase Measurement — gas with liquid • API Referral • Gas Standard Volume Procedure 1. Choose Device Settings → Device Information → Licenses → Enable/Disable Applications and ensure that Volume Flow Type is set to Liquid. 2. Choose Device Settings → Device Information → Licenses → Enable/Disable Applications. 3. Enable the concentration measurement application. Set reference temperature values for specific gravity using a field communicator Field communicator Device Settings → Process Configuration → Optional Setup → Concentration Measurement → Configure Matrix → Reference Conditions When Derived Variable is set to any option based on specific gravity, you must set the reference temperature for water, then verify the density of water at the configured reference temperature. These values affect specific gravity measurement. To check the setting of Derived Variable, choose Device Settings → Process Configuration → Optional Setup → Concentration Measurement → CM Configuration. Important Do not change the setting of Derived Variable. If you change the setting of Derived Variable, all existing concentration matrices will be deleted from transmitter memory. Procedure 1. Set Matrix Being Configured to the matrix you want to modify. 2. Choose Reference Conditions, then perform the following actions: a) Set Reference Temperature to the temperature to which line density will be corrected for use in the specific gravity calculation. b) Set Water Reference Temperature to the water temperature that will be used in the specific gravity calculation. c) Set Water Reference Density to the density of water at the specified reference temperature. Configuration and Use Manual 69 Configure process measurement applications May 2024 Configuration and Use Manual MS-00809-0200-1600 The transmitter automatically calculates the density of water at the specified temperature. The new value will be displayed the next time that transmitter memory is read. Optionally, you can enter a different value. Modify matrix names and labels using a field communicator Field communicator Device Settings → Process Configuration → Optional Setup → Concentration Measurement → Configure Matrix For convenience, you can change the name of a concentration matrix and the label used for its measurement unit. This does not affect measurement. Procedure 1. Set Matrix Being Configured to the matrix you want to modify. 2. Set Matrix Name to the name to be used for the matrix. 3. Set Concentration Unit to the label that will be used for the concentration unit. 4. If you set Concentration Unit to Special, choose Label and enter the custom label. Modify extrapolation alerts using a field communicator You can enable and disable extrapolation alerts, and set extrapolation alert limits. These parameters control the behavior of the concentration measurement application but do not affect measurement directly. Each concentration matrix is built for a specific density range and a specific temperature range. If line density or line temperature goes outside the range, the transmitter will extrapolate concentration values. However, extrapolation may affect accuracy. Extrapolation alerts are used to notify the operator that extrapolation is occurring. Each concentration matrix has its own extrapolation alert limits. Procedure 1. Choose Device Settings → Process Configuration → Optional Setup → Concentration Measurement → Configure Matrix. 2. Set Matrix Being Configured to the matrix you want to modify. 3. Set Extrapolation Alert Limit to the point, in percent, at which an extrapolation alert will be posted. 4. Choose Device Settings → Alerts → Alert Setup → CM Extrapolation Alerts. 5. Enable or disable the high and low alerts for temperature and density, as desired. Extrapolation alerts in action If Extrapolation Limit is set to 5%, High Limit (Temp) is enabled, and the active matrix is built for a temperature range of 40 °F (4.4 °C) to 80 °F (26.7 °C), a high-temperature extrapolation alert will be posted if line temperature goes above 82 °F (27.8 °C). Select the active concentration matrix using a field communicator Field communicator Device Settings → Process Configuration → Optional Setup → Concentration Measurement → CM Configuration You must select the concentration matrix to be used for measurement. Although the transmitter can store up to six concentration matrices, only one matrix can be used for measurement at any one time. Procedure Set Active Matrix to the matrix you want to use. 70 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure advanced options for process measurement May 2024 6 Configure advanced options for process measurement 6.1 Configure Response Time Display Menu → Configuration → Process Measurement → Response Time ProLink III Device Tools → Configuration → Process Measurement → Response Time Field communicator Not available Response Time controls the speed of various internal processes that are involved in retrieving electronic data from the sensor and converting it to process data. Response Time affects all process and diagnostic variables. Procedure Set Response Time as desired. Option Description Normal Appropriate for typical applications. High Filtering Slower response. Appropriate for applications with significant amount of entrained gas or process noise. Low Filtering Fastest response. Appropriate for proving or filling applications. 6.2 Detect and report two-phase flow Two-phase flow (gas in a liquid process or liquid in a gas process) can cause a variety of process control issues. The transmitter provides two methods to detect and report or respond to two-phase flow. 6.2.1 Detect two-phase flow using density Display Menu → Configuration → Process Measurement → Density ProLink III Device Tools → Configuration → Process Measurement → Density → Expand Two-Phase Flow Field communicator Device Settings → Process Configuration → Two-Phase Flow The transmitter can use line density data to detect two-phase flow (gas in a liquid process or liquid in a gas process). The density limits are user-specified. When two-phase flow is detected, an alert is posted. Procedure 1. Set Two-Phase Flow Low Limit to the lowest density value that is considered normal in your process. Values below this will cause the transmitter to post a Process Aberration alert. If no two-phase flow is expected, leave this value at 0. Tip Gas entrainment can cause your process density to drop temporarily. To reduce the occurrence of two-phase flow alerts that are not significant to your process, set Two-Phase Flow Low Limit slightly below your expected lowest process density. Configuration and Use Manual 71 Configure advanced options for process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 You must enter Two-Phase Flow Low Limit in g/cm³, even if you configured another unit for density measurement. • Default: 0 g/cm³ • Range: 0 g/cm³ to the sensor limit 2. Set Two-Phase Flow High Limit to the highest density value that is considered normal in your process. Values above this will cause the transmitter to post a Process Aberration alert. Tip To reduce the occurrence of two-phase flow alerts that are not significant to your process, set TwoPhase Flow High Limit slightly above your expected highest process density. For most applications, leaving the Two-Phase Flow High Limit at 5.0 g/cc will suffice. You must enter Two-Phase Flow High Limit in g/cm³, even if you configured another unit for density measurement. • Default: 5 g/cm³ • Range: 5 g/cm³ to the sensor limit 3. Set Two-Phase Flow Timeout to the number of seconds that the transmitter will wait for a two-phase flow condition to clear before posting the alert. • Default: 0 seconds, meaning that the alert will be posted immediately • Range: 0 to 60 seconds 6.2.2 Detect two-phase flow using sensor diagnostics Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Source ProLink III Device Tools → Configuration → I/O → Channels → Channel B → mA Output Field communicator Device Settings → Inputs/Outputs → Mapping/Source → Output Source → mAO x Source The transmitter always monitors sensor diagnostics and applies a two-phase flow algorithm. You can assign an mA Output to report the results of this calculation: single-phase flow, moderate two-phase flow, or severe two-phase flow. Severe two-phase flow can cause the meter to stop functioning. Prerequisites Channel B must be configured as mA Output. Procedure Set mA Output Source to Two-Phase Flow Detection. The signal from the mA Output indicates the current state of the process: • 12 mA: Single-phase flow • 16 mA: Moderate two-phase flow • 20 mA: Severe two-phase flow 6.3 Configure Flow Rate Switch Display Menu → Configuration → Alert Setup → Enhanced Events → Flow Rate Switch ProLink III Device Tools → Configuration → I/O → Outputs → Discrete Output → Source → Flow Switch Indication 72 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Field communicator Configure advanced options for process measurement May 2024 Device Settings → Inputs/Outputs → Discrete Output x → Flow Switch Flow Rate Switch is used to indicate that the flow rate has moved past a user-specified setpoint, in either direction. The flow rate switch is implemented with a user-configurable hysteresis. Typically, a Discrete Output is assigned as the flow rate switch indicator. The Discrete Output can be wired to an external device such as a light or a horn. Prerequisites A channel must be configured as a Discrete Output, and the Discrete Output must be available for this use. Procedure 1. Set Discrete Output Source to Flow Switch, if you have not already done so. 2. Set Flow Switch Variable to the flow variable that you want to use to control the flow rate switch. 3. Set Flow Switch Setpoint to the value at which the flow switch will be triggered (after Hysteresis is applied). Depending on the polarity of the Discrete Output: • If the flow rate is below this value, the Discrete Output is ON. • If the flow rate is above this value, the Discrete Output is OFF. 4. Set Hysteresis to the percentage of variation above and below the setpoint that will operate as a deadband. Hysteresis defines a range around the setpoint within which the flow rate switch will not change. • Default: 5% • Range: 0.1% to 10% Example If Flow Switch Setpoint = 100 g/sec and Hysteresis = 5%, and the first measured flow rate is above 100 g/sec, the discrete output is OFF. It will remain OFF unless the flow rate drops below 95 g/sec. If this happens, the discrete output will turn ON, and remain ON until the flow rate rises above 105 g/sec. At this point it turns OFF and will remain OFF until the flow rate drops below 95 g/sec. Related information Configure a Discrete Output 6.4 Configure events An event occurs when the real-time value of a user-specified process variable moves past a user-defined setpoint. Events are used to provide notification of process changes or to perform specific transmitter actions if a process change occurs. 6.4.1 Configure a basic event Display Not available ProLink III Device Tools → Configuration → Events → Basic Events Field communicator Not available Configuration and Use Manual 73 Configure advanced options for process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 A basic event is used to provide notification of process changes. A basic event occurs (is ON) if the real-time value of a user-specified process variable moves above (HI) or below (LO) a user-defined setpoint. Event status can be queried via digital communications, and a Discrete Output can be configured to report event status. You can define up to two basic events. Procedure 1. Select the event that you want to configure. 2. Assign a process variable to the event. 3. Specify Event Type. Option Description HI x>A The event occurs when the value of the assigned process variable (x) is greater than the setpoint (Setpoint A), endpoint not included. LO x<A The event occurs when the value of the assigned process variable (x) is less than the setpoint (Setpoint A), endpoint not included. 4. Set a value for Setpoint A. 5. Optional: Configure a Discrete Output to switch states in response to the event status. 6.4.2 Configure an enhanced event Display Menu → Configuration → Alert Setup → Enhanced Events ProLink III Device Tools → Configuration → Events → Enhanced Events Field communicator Device Settings → Alerts → Alert Setup → Enhanced Events An enhanced event is used to provide notification of process changes and, optionally, to perform specific transmitter actions if the event occurs. An enhanced event occurs (is ON) if the real-time value of a userspecified process variable moves above (HI) or below (LO) a user-defined setpoint, or in range (IN) or out of range (OUT) with respect to two user-defined setpoints. You can define up to five enhanced events. For each enhanced event, you can assign one or more actions that the transmitter will perform if the enhanced event occurs. Procedure 1. Select the event that you want to configure. 2. Assign a process variable to the event. 3. Specify Event Type. 74 Option Description HI x>A The event occurs when the value of the assigned process variable (x) is greater than the setpoint (Setpoint A), endpoint not included. LO x<A The event occurs when the value of the assigned process variable (x) is less than the setpoint (Setpoint A), endpoint not included. IN A≤x≤B Emerson.com Configuration and Use Manual MS-00809-0200-1600 Option Configure advanced options for process measurement May 2024 Description The event occurs when the value of the assigned process variable (x) is in range, that is, between Setpoint A and Setpoint B, endpoints included. OUT x ≤ A or x ≥ B The event occurs when the value of the assigned process variable (x) is out of range, that is, less than Setpoint A or greater than Setpoint B, endpoints included. 4. Set values for the required setpoints. • For HI and LO events, set Setpoint A. • For IN and OUT events, set Setpoint A and Setpoint B. 5. Optional: Configure a Discrete Output to switch states in response to the event status. 6. Optional: Specify the action or actions that the transmitter will perform when the event occurs. Option Description Display Menu → Configuration → Alert Setup → Enhanced Events, select any enhanced event, and choose Assign Actions ProLink III Device Tools → Configuration → I/O → Inputs → Action Assignment Field communicator Device Settings → Alerts → Alert Setup → Enhanced Events Options for Enhanced Event Action Action Label Display ProLink III Field communicator Start Zero Calibration Start Sensor Zero Start Sensor Zero Start/stop all totalizers and inventories Start/stop all totalizers Start or Stop All Totalizers Start/Stop All Totals Reset totalizer X Reset Total X Totalizer X Reset Total X Reset all totalizers and inventories Reset All Totals Reset All Totals Reset All Totals Increment Matrix Increment ED Curve Increment Curve Standard Start sensor zero Totalizers Concentration measurement Increment CM matrix Smart Meter Verification Start Meter Verification test Start Smart Meter Verification 6.5 Configure totalizers and inventories Display Menu → Configuration → Process Measurement → Totalizers & Inventories ProLink III Device Tools → Totalizer Control → Totalizers Configuration and Use Manual 75 Configure advanced options for process measurement May 2024 Field communicator Configuration and Use Manual MS-00809-0200-1600 Device Settings → Process Configuration → Optional Setup → Configure Totalizers/Inventories The transmitter provides seven configurable totalizers and seven configurable inventories. Each totalizer and each inventory can be configured independently. Totalizers track the process since the last totalizer reset. Inventories track the process since the last inventory reset. Inventories are typically used to track the process across totalizer resets. Tip The default configurations cover the most typical uses of totalizers and inventories. You may not need to change any configurations. Prerequisites Before configuring the totalizers and inventories, ensure that the process variables you plan to track are available on the transmitter. Procedure 1. Select the totalizer or inventory that you want to configure. 2. Set Totalizer Source or Inventory Source to the process variable that the totalizer or inventory will track. Option Description Mass flow The totalizer or inventory will track Mass Flow Rate and calculate total mass since the last reset. Volume flow The totalizer or inventory will track Volume Flow Rate and calculate total volume since the last reset. Gas standard volume flow The totalizer or inventory will track Gas Standard Volume Flow Rate and calculate total volume since the last reset. Temperature-corrected volume flow The totalizer or inventory will track Temperature-Corrected Volume Flow Rate and calculate total volume since the last reset. Standard volume flow The totalizer or inventory will track Standard Volume Flow Rate and calculate total volume since the last reset. Net mass flow The totalizer or inventory will track Net Mass Flow Rate and calculate total mass since the last reset. Net volume flow The totalizer or inventory will track Net Volume Flow Rate and calculate total volume since the last reset. Note The totalizer/inventory value will not automatically be reset when the source is changed. The user must manually reset the totalizer/inventory. Tip If you are using the API Referral application and you want to measure batch-weighted average density or batch-weighted average temperature, you must have a totalizer configured to measure temperaturecorrected volume flow. 3. Set Totalizer Direction to specify how the totalizer or inventory will respond to forward or reverse flow. 76 Option Flow direction Totalizer and inventory behavior Forward Only Forward Totals increment Reverse Totals do not change Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure advanced options for process measurement May 2024 Option Flow direction Totalizer and inventory behavior Reverse Only Forward Totals do not change Reverse Totals increment Forward Totals increment Reverse Totals decrement Forward Totals increment Reverse Totals increment Bidirectional Absolute Value Important Actual flow direction interacts with Sensor Flow Direction Arrow to determine the flow direction that the transmitter uses in processing. See the following table. Table 6-1: Interaction between actual flow direction and Sensor Flow Direction Arrow Setting of Sensor Flow Direction Arrow Flow direction sent to outputs and totalizers Forward (same direction as Flow arrow on sensor) With Arrow Forward Against Arrow Reverse Reverse (opposite from Flow arrow on sensor) With Arrow Reverse Against Arrow Forward Actual flow direction 4. Optional: Set User Name to the name you want to use for the inventory or totalizer. User-Defined Label can have a maximum of 16 characters. The transmitter automatically generates a name for each totalizer and inventory, based on its source, direction, and type. Example • Source = Mass Flow • Direction = Forward Only • User-Defined Label = Mass Fwd Total Example • Source = Gas Standard Volume Flow • Direction = Bidirectional • User-Defined Label = GSV Bidir Inv The specified name is used on the transmitter display and on all interfaces that support it. If User Name contains only spaces, the transmitter-generated name is used. Not all interfaces support totalizer and inventory names. Example: Checking for backflow You suspect that there is a significant amount of backflow through the sensor. To collect data, configure two totalizers as follows: • Source = Mass Flow, Direction = Forward Only • Source = Mass Flow, Direction = Reverse Only Configuration and Use Manual 77 Configure advanced options for process measurement May 2024 Configuration and Use Manual MS-00809-0200-1600 Reset both totalizers, allow them to run for an appropriate period, then look at the amount of reverse flow as a percentage of forward flow. Example: Tracking three different process fluids Three tanks are connected to a loading dock through a single meter. Each tank contains a different process fluid. You want to track each process fluid separately. 1. Set up three totalizers, one for each tank. 2. Name the totalizers Tank 1, Tank 2, and Tank 3. 3. Configure each totalizer as required for the corresponding process fluid. 4. Stop and reset all three totalizers to ensure that the beginning values are 0. 5. When loading from a tank, start the corresponding totalizer, and stop it when the load is finished. 6.5.1 Default settings for totalizers and inventories Totalizer or inventory Source (process variable assignment Direction Name of totalizer Name of inventory 1 Mass flow Forward Only Mass Fwd Total Mass Fwd Inv 2 Volume flow Forward Only Volume Fwd Total Volume Fwd Inv 3 Temperature-corrected volume flow Forward Only API Volume Fwd Total API Volume Fwd Inv 4 Gas standard volume flow Forward Only GSV Fwd Total GSV Fwd Inv 5 Standard volume flow Forward Only Standard Vol Fwd Total Standard Vol Fwd Inv 6 Net mass flow Forward Only Net Mass Fwd Total Net Mass Fwd Inv 7 Net volume flow Forward Only Net Vol Fwd Total Net Vol Fwd Inv 6.6 Configure logging for totalizers and inventories Display Menu → Configuration → Totalizer Log ProLink III Device Tools → Configuration → Totalizer Log Field communicator Not available The transmitter can write the current value of four totalizers or inventories to a log, at user-specified intervals. You can generate a log file from this data for viewing and analysis. Procedure 1. Specify the date on which totalizer logging will begin. You must specify a future date. If you try to specify the current date, the transmitter will reject the setting. 2. Specify the time at which totalizer logging will begin. 78 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure advanced options for process measurement May 2024 3. Specify the number of hours between records. 4. Select up to four totalizers or inventories to be logged. 6.7 Configure Process Variable Fault Action Display Menu → Configuration → Alert Setup → Output Fault Actions ProLink III Device Tools → Configuration → Fault Processing Field communicator Device Settings → Alerts → Alert Setup → Output Fault Action Process Variable Fault Action specifies the values that will be reported via the display and digital communications if the device encounters a fault condition. The values are also sent to the outputs for processing against their configured fault actions. Procedure Set Process Variable Fault Action as desired. Default: None Restriction If you set Process Variable Fault Action to NAN, you cannot set mA Output Fault Action or Frequency Output Fault Action to None. If you try to do this, the transmitter will not accept the configuration. Important • If you want the mA Output to continue reporting process data during fault conditions, you must set both Process Variable Fault Action and mA Output Fault Action to None. If mA Output Fault Action is set to None and Process Variable Fault Action is set to any other option, the mA Output will produce the signal associated with the selection. • If you want the Frequency Output to continue reporting process data during fault conditions, you must set both Process Variable Fault Action and Frequency Output Fault Action to None. If Frequency Output Fault Action is set to None and Process Variable Fault Action is set to any other option, the Frequency Output will produce the signal associated with the selection. 6.7.1 Options for Process Variable Fault Action Label Display ProLink III Upscale Upscale Downscale Downscale Configuration and Use Manual Description • Process variable values indicate that the value is greater than the upper sensor limit. • Totalizers stop incrementing. • Process variable values indicate that the value is lower than the lower sensor limit. • Totalizers stop incrementing. 79 Configure advanced options for process measurement May 2024 Label Display ProLink III Zero Zero Not-a-Number (NAN) Flow to Zero None (default) Not a Number Flow to Zero None Configuration and Use Manual MS-00809-0200-1600 Description • Flow rate variables go to the value that represents a flow rate of 0 (zero). • Density is reported as 0. • Temperature is reported as 0 °C , or the equivalent if other units are used (e.g., 32 °F . • Drive gain is reported as measured. • Totalizers stop incrementing. • Process variables are reported as IEEE NAN. • Drive gain is reported as measured. • Modbus scaled integers are reported as Max Int. • Totalizers stop incrementing. • Flow rates are reported as 0. • Other process variables are reported as measured. • Totalizers stop incrementing. • All process variables are reported as measured. • Totalizers increment if they are running. 6.7.2 Interaction between Process Variable Fault Action and other fault actions The setting of Process Variable Fault Action affects the operation of the mA Outputs, Frequency Outputs, and Discrete Outputs if the corresponding output fault actions are set to None. Interaction between Process Variable Fault Action and mA Output Fault Action If mA Output Fault Action is set to None, the mA Output signal depends on the setting of Process Variable Fault Action. If the device detects a fault condition: 1. Process Variable Fault Action is evaluated and applied. 2. mA Output Fault Action is evaluated. • If it is set to None, the output reports the value associated with the setting of Process Variable Fault Action. • If it is set to any other option, the output performs the specified fault action. If you want the mA Output to continue to report process data during fault conditions, you must set both mA Output Fault Action and Process Variable Fault Action to None. Interaction between Process Variable Fault Action and Frequency Output Fault Action If Frequency Output Fault Action is set to None, the Frequency Output signal depends on the setting of Process Variable Fault Action. If the device detects a fault condition: 1. Process Variable Fault Action is evaluated and applied. 80 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure advanced options for process measurement May 2024 2. Frequency Output Fault Action is evaluated. • If it is set to None, the output reports the value associated with the setting of Process Variable Fault Action. • If it is set to any other option, the output performs the specified fault action. If you want the Frequency Output to continue to report process data during fault conditions, you must set both Frequency Output Fault Action and Process Variable Fault Action to None. Interaction between Process Variable Fault Action and Discrete Output Fault Action If Discrete Output Fault Action is set to None and Discrete Output Source is set to Flow Rate Switch, the Discrete Output state during a fault depends on the setting of Process Variable Fault Action. If the device detects a fault condition: 1. Process Variable Fault Action is evaluated and applied. 2. Discrete Output Fault Action is evaluated. • If it is set to None, and Discrete Output Source is set to Flow Rate Switch, the Discrete Output will use the value determined by the current setting of Process Variable Fault Action to determine if a flow rate switch has occurred. • If Discrete Output Source is set to any other option, the setting of Process Variable Fault Action is irrelevant to the behavior of the Discrete Output during fault conditions. The Discrete Output is set to the specified fault action. If you want the Discrete Output to report a flow rate switch appropriately during fault conditions, you must set both Discrete Output Fault Action and Process Variable Fault Action to None. Related information Configure mA Output Fault Action Configure Frequency Output Fault Action Configure Discrete Output Fault Action Configuration and Use Manual 81 Configure advanced options for process measurement May 2024 82 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure device options and preferences May 2024 7 Configure device options and preferences 7.1 Configure the transmitter display You can control the language used on the display, the process variables shown on the display, and a variety of display behaviors. 7.1.1 Configure the language used on the display Display Menu → Configuration → Display Settings → Language ProLink III Device Tools → Configuration → Transmitter Display → General → Language Field communicator Device Settings → Display → Display Language → Language Language controls the language that the display uses for process data, menus, and information. The languages available depend on your transmitter model and version. Procedure Set Language to the desired language. 7.1.2 Configure the process variables shown on the display Display Menu → Configuration → Display Settings → Display Variables ProLink III Device Tools → Configuration → Transmitter Display → Display Variables Field communicator Device Settings → Display → Display Variables You can control the process variables shown on the display and the order in which they appear. The display can scroll through up to 15 process variables in any order you choose. This configuration applies to both auto-scroll and manual scrolling. By default, one process variable is shown at a time. You can configure a custom display screen that shows two process variables at a time. Restriction You cannot remove all display variables. At least one display variable must be configured. Notes • If you have a display variable configured to show a volume process variable, and you change Volume Flow Type to Gas Standard Volume, the display variable is automatically changed to the equivalent GSV variable, and vice versa. • For all other display variables, if the process variable becomes unavailable due to changes in configuration, the transmitter will not display that variable. Procedure For each display variable, select the process variable to be shown in that position in the rotation. You can skip positions and you can repeat process variables. Configuration and Use Manual 83 Configure device options and preferences May 2024 Configuration and Use Manual MS-00809-0200-1600 Table 7-1: Default configuration for display variables Display variable Process variable assignment Display Variable 1 Mass flow rate Display Variable 2 Mass total Display Variable 3 Volume flow rate Display Variable 4 Volume total Display Variable 5 Density Display Variable 6 Temperature Display Variable 7 Drive gain Display Variable 8 None Display Variable 9 None Display Variable 10 None Display Variable 11 None Display Variable 12 None Display Variable 13 None Display Variable 14 None Display Variable 15 None 7.1.3 Configure a two-line display screen Display Menu → Configuration → Display Settings → Display Variables → 2-Value View ProLink III Device Tools → Configuration → Transmitter Display → Display Variables → 2 PV Screen Slot #X Field communicator Device Settings → Display → General Settings → Language You can configure one display screen to show two process variables at a time. For each of these process variables, the current value and the measurement is shown. The two-line display screen operates like one of the basic 15 screens. You can use ˅ and ˄ to scroll to it. If Auto Scroll is enabled, the two-line screen will be the last screen in the cycle. 7.1.4 Configure the number of decimal places (precision) shown on the display Display Menu → Configuration → Display Settings → Decimals on Display ProLink III Device Tools → Configuration → Transmitter Display → Display Variables → Decimal Places for x Field communicator Device Settings → Display → Decimal Places You can specify the precision (the number of decimal places) that the display uses for each display variable. You can set the precision independently for each display variable. The display precision does not affect the actual value of the variable, the value used in calculations, or the value reported via outputs or digital communications. Procedure 1. Select a process variable or a diagnostic variable. 84 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure device options and preferences May 2024 You can configure the precision for all variables, whether or not they are assigned as display variables. The configured precision will be stored and used when applicable. 2. Set Number of Decimal Places to the number of decimal places to be used when this variable is shown on the display. • Default: — Temperature variables: 2 — All other variables: 4 • Range: 0 to 5 Tip The lower the precision, the greater the change must be for it to be reflected on the display. Do not set Number of Decimal Places too low to be useful. 7.1.5 Turn on and turn off automatic scrolling through the display variables Display Menu → Configuration → Display Settings → Auto Scroll ProLink III Device Tools → Configuration → Transmitter Display → General → Auto Scroll Field communicator Device Settings → Display → Display Behavior → Auto Scroll You can configure the display to automatically scroll through the list of display variables or to show a single display variable until the operator activates Scroll. If Auto Scroll is turned on, you can configure the number of seconds that each display variable will be shown. Procedure 1. Turn on or turn off Auto Scroll as desired. Option Description On The display automatically shows each display variable for the number of seconds specified by Scroll Rate, then shows the next display variable. The operator can move to the next display variable at any time by activating Scroll. Off The display shows Display Variable 1 and does not scroll automatically. The operator can move to the next display variable at any time by activating Scroll. Default: Off 2. If you turned on Auto Scroll, set Scroll Rate as desired. • Default: 10 • Range: 1 to 30 seconds Tip Scroll Rate may not be available until you apply Auto Scroll. 7.1.6 Configure the display backlight Display Menu → Configuration → Display Settings ProLink III Device Tools → Configuration → Transmitter Display → General → Backlight Configuration and Use Manual 85 Configure device options and preferences May 2024 Field communicator Configuration and Use Manual MS-00809-0200-1600 Device Settings → Display → Backlight You can control the intensity and contrast of the backlight on the display's LCD panel. Procedure You can set the backlight and Auto Contrast on the display's LCD panel to either ON or OFF. When Auto Contrast is OFF, you can also set Contrast as desired (Default: 50). 7.1.7 Configure security for the display Display Menu → Configuration → Security → Display Security ProLink III Device Tools → Configuration → Transmitter Display → Display Security Field communicator Device Settings → Display → Display Behavior When using the display, you can require users to enter a password to do any of the following tasks: • Enter the main menu • Change a parameter • Access alert data through the display • Start, stop, or reset totalizers or inventories via the context menu The display password can be the same or different from the totalizer/inventory context menu control password. If different, the display password is used to reset, start, and stop totalizers or inventories using Menu → Operations → Totalizers. Procedure 1. Configure Password Required as desired. Option Description At Write When an user chooses an action that leads to a configuration change, they are prompted to enter the display password. Enter Menu When the menu is selected from the process variable screen, the display password will be immediately required if Password Required is set. Never (default) When a user chooses an action that leads to a configuration change, they are prompted to enter a specific button sequence ( ⇦⇧⇩⇨). This is designed to protect against accidental changes to configuration. It is not a security measure. 2. If the At Write or Enter Menu option was selected, enable or disable alert security as desired. Option Description Enabled If an alert is active, the alert symbol ⓘ is shown in the lower right corner of the display but the alert banner is not displayed. If the operator attempts to enter the alert menu, they are prompted to enter the display password. Disabled If an alert is active, the alert symbol ⓘ is shown in the lower right corner of the display and the alert banner is displayed automatically. No password or confirmation is required to enter the alert menu. 86 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure device options and preferences May 2024 Restriction You cannot set Password Required to Never and enable alert security. • If you did not enable Password Required, alert security is disabled and cannot be enabled. • Alert security is disabled automatically if you set Password Required to Never after: — Password Required is initially set to either At Write or Enter Menu. — Alert security is enabled. 3. If Password Required has been set to At Write or Enter Menu, you will be prompted to enter the desired password. • Default: AAAA • Range: Any four alphanumeric characters • Password Required must be set to At Write or Enter Menu to enable the totalizer/inventory control context menu password option. Important If you enable Password Required but you do not change the display password, the transmitter will post a configuration alert. 4. Configure Main Menu Available as desired. Option Description Enabled The local display Menu option from the process variable screen will be accessible. Disabled The local display Menu option from the process variable screen will not be accessible. Important Once Main Menu Available is disabled, it cannot be enabled from the local display. Use another configuration tool, such as ProLink III, to re-enable main menu access from the local display. 7.1.8 Configure totalizer and inventory control Display Menu → Configuration → Security → Display Security → Totalizers & Inventories ProLink III Device Tools → Configuration → Totalizer Control Methods Field communicator Device Settings → Display → Display Behavior You can enable or disable the operator's ability to start, stop, or reset totalizers or inventories. The totalizer/ inventory control context menus password can also be configured. The context menu is accessed by selecting the options menu from the process variable screen when a total or inventory is displayed. These parameters do not affect the operator's ability to start, stop, or reset totalizers or inventories using another tool. Procedure 1. Enable or disable Reset Totalizers, as desired. Default = Enable 2. Enable or disable Start/Stop Totalizers, as desired. Default = Enable 3. Enable or disable Reset Inventory, as desired. Configuration and Use Manual 87 Configure device options and preferences May 2024 Configuration and Use Manual MS-00809-0200-1600 Default = Disable 4. Enable or disable Start/Stop Inventory, as desired. Default = Disable 5. If required, configure the totalizer/inventory control context menu password. Option Description No password (default) Start, stop or reset totalizer/inventory actions via the context menu do not require a password. Password Required When a user selects Start/Stop or Reset from the context menu and the password is enabled for totalizer/inventory control, the user is required to enter a password before the action occurs. If the context menu password option has been set to Password Required, you will be prompted to enter the password. • Default: AAAA • Range: Any four alphanumeric characters • The display Password Required must be set to At Write or Enter Menu to enable the totalizer/ inventory control context menu password option. Important If you enable Password Required for totalizers and inventories, but you do not change the password from the default, the transmitter will post a configuration alert. 7.2 Configure the transmitter response to alerts 7.2.1 Configure the transmitter response to alerts using the display For some alerts, you can change the transmitter response to an alert by setting the alert severity. You can also configure the transmitter to ignore some alerts and conditions. The transmitter implements the NAMUR NE 107 specification for alerts. NAMUR NE 107 categorizes alerts by the suggested operator action, not by cause or symptom. Each alert has one or more associated conditions. Important The transmitter reports all the process and device conditions that were reported by previous transmitters. However, the transmitter does not report them as individual alerts. Instead, the transmitter reports them as conditions associated with alerts. Procedure • To change the severity of an alert: a) Choose Menu → Configuration → Alert Setup → Response to Alerts. b) Select the alert. c) Set Alert Severity as desired. 88 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure device options and preferences May 2024 Option Description Failure The event is serious enough to require fault actions by the transmitter. The event may be either device-related or process-related. Operator action is strongly recommended. Function Check Configuration change or device testing. No fault actions are performed. The operator may need to complete a procedure. • Out of Specification The process is outside user-specified limits or device limits. No fault actions are performed. The operator should check the process. Maintenance Required Device maintenance is recommended, either near-term or mid-term. To ignore an alert: a) Choose Menu → Configuration → Alert Setup → Response to Alerts. b) Select the alert. c) Set Alert Detection to Ignore. If an alert is ignored, any occurrence of this alert is not posted to the alert list and the status LED on the transmitter does not change color. The occurrence is posted to alert history. • To ignore a condition: a) Choose Menu → Configuration → Alert Setup → Response to Alerts. b) Select the alert associated with the condition. c) Select Condition Detection. d) Select the condition and set it to Ignore. If a condition is ignored, any occurrence of this condition is not posted to the alert list and the status LED on the transmitter does not change color. The occurrence is posted to alert history. 7.2.2 Configure the transmitter response to alerts using ProLink III For some alerts, you can change the transmitter response to an alert by setting the alert severity. You can also configure the transmitter to ignore some alerts and conditions. The transmitter implements the NAMUR NE 107 specification for alerts. NAMUR NE 107 categorizes alerts by the suggested operator action, not by cause or symptom. Each alert has one or more associated conditions. Important The transmitter reports all the process and device conditions that were reported by previous transmitters. However, the transmitter does not report them as individual alerts. Instead, the transmitter reports them as conditions associated with alerts. Procedure • To change the severity of an alert: a) Choose Device Tools → Configuration → Alert Severity. b) Select the alert. c) Set the severity as desired. Configuration and Use Manual 89 Configure device options and preferences May 2024 Configuration and Use Manual MS-00809-0200-1600 Option Description Failure The event is serious enough to require fault actions by the transmitter. The event may be either device-related or process-related. Operator action is strongly recommended. Function Check Configuration change or device testing. No fault actions are performed. The operator may need to complete a procedure. • Out of Specification The process is outside user-specified limits or device limits. No fault actions are performed. The operator should check the process. Maintenance Required Device maintenance is recommended, either near-term or mid-term. To ignore an alert: a) Choose Device Tools → Configuration → Alert Severity. b) Select the alert. c) Set the severity to Ignore. If an alert is ignored, any occurrence of this alert is not posted to the alert list and the status LED on the transmitter does not change color. The occurrence is posted to alert history. • To ignore a condition: a) Choose Menu → Configuration → Alert Setup → Response to Alerts. b) Select the alert associated with the condition and expand it. c) Select the condition and set it to Ignore. If a condition is ignored, any occurrence of this condition is not posted to the alert list and the status LED on the transmitter does not change color. The occurrence is posted to alert history. 7.2.3 Configure the transmitter response to alerts using a field communicator For some alerts, you can change the transmitter response to an alert by setting the alert severity. You can also configure the transmitter to ignore some alerts and conditions. The transmitter implements the NAMUR NE 107 specification for alerts. NAMUR NE 107 categorizes alerts by the suggested operator action, not by cause or symptom. Each alert has one or more associated conditions. Important The transmitter reports all the process and device conditions that were reported by previous transmitters. However, the transmitter does not report them as individual alerts. Instead, the transmitter reports them as conditions associated with alerts. Procedure • To change the severity of an alert: a) Choose Device Settings → Alerts → Alert Setup. b) Choose the category of the alert: Sensor, Configuration, Process, or Output. c) Select the alert. d) Set the severity as desired. 90 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure device options and preferences May 2024 Option Description Failure The event is serious enough to require fault actions by the transmitter. The event may be either device-related or process-related. Operator action is strongly recommended. Function Check Configuration change or device testing. No fault actions are performed. The operator may need to complete a procedure. • Out of Specification The process is outside user-specified limits or device limits. No fault actions are performed. The operator should check the process. Maintenance Required Device maintenance is recommended, either near-term or mid-term. To ignore an alert: a) Choose Device Settings → Alerts → Alert Setup. b) Choose the category of the alert: Sensor, Configuration, Process, or Output. c) Select the alert. d) Set the severity to No Effect. If an alert is ignored, any occurrence of this alert is not posted to the alert list and the status LED on the transmitter does not change color. The occurrence is posted to alert history. • To ignore a condition: a) Choose Device Settings → Alerts → Alert Setup. b) Choose the category of the alert: Sensor, Configuration, Process, or Output. c) Select the alert. d) Choose Set Conditions. e) Select the condition and set it to OFF. If a condition is ignored, any occurrence of this condition is not posted to the alert list and the status LED on the transmitter does not change color. The occurrence is posted to alert history. 7.2.4 Configure Fault Timeout Display Menu → Configuration → Alert Setup → Output Fault Actions → Fault Timeout (sec) ProLink III Device Tools → Configuration → Fault Processing → Fault Timeout Field communicator Device Settings → Alerts → Alert Setup → Output Fault Action → General → Fault Timeout Fault Timeout controls the delay before fault actions are performed. The fault timeout period begins when the transmitter detects an alert condition. • During the fault timeout period, the transmitter continues to report its last valid measurements. • If the fault timeout period expires while the alert is still active, the fault actions are performed. • If the alert condition clears before the fault timeout expires, no fault actions are performed. Restriction • Fault Timeout is not applied to all alerts. For some alerts, fault actions are performed as soon as the alert condition is detected. See the list of alerts and conditions for details. • Fault Timeout is applicable only when Alert Severity = Failure. For all other settings of Alert Severity, Fault Timeout is irrelevant. Configuration and Use Manual 91 Configure device options and preferences May 2024 Configuration and Use Manual MS-00809-0200-1600 Procedure Set Fault Timeout as desired. • Default: 0 seconds • Range: 0 to 60 seconds If you set Fault Timeout to 0, fault actions are performed as soon as the alert condition is detected. 7.2.5 Alerts, conditions, and configuration options For more information on these alerts, see Status alerts, causes, and recommendations. Configuration Error Default severity: Failure Severity configurable: No Fault Timeout applicable: No Table 7-2: Configuration Error conditions Name Ignorable [020] Calibration Factors Missing No [021] Incorrect Sensor Type Yes [030] Incorrect Board Type No Core Processor Update Failed Yes Password Not Set No Time Not Entered Yes Batcher Not Configured Yes [120] Curve Fit Failure (Concentration) No Core Low Power Default severity: Failure Severity configurable: No Fault Timeout applicable: No Table 7-3: Core Low Power conditions Name Ignorable [031] Low Power No Configuration Warning Default severity: Maintenance Required Severity configurable: Yes Fault Timeout applicable: No Table 7-4: Configuration Warning conditions Name Ignorable No Permanent License No Clock Failure No 92 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure device options and preferences May 2024 Table 7-4: Configuration Warning conditions (continued) Name Ignorable Transmitter Software Update Failed Yes Drive Over Range Default severity: Maintenance Severity configurable: Yes Fault Timeout applicable: Yes Table 7-5: Drive Over-Range conditions Name Ignorable [102] Drive Overrange Yes Electronics Failed Default severity: Failure Severity configurable: No Fault Timeout applicable: No Table 7-6: Electronics Failed conditions Name Ignorable [018] EEPROM Error (Transmitter) No [019] RAM Error (Transmitter) No Watchdog Error No Event Active Default severity: Out of Speculation Severity configurable: Yes Fault Timeout applicable: Yes Table 7-7: Event Active conditions Name Ignorable Enhanced Event [1 - 5] Active Yes Event [1 - 2] Active Yes Extreme Primary Purpose Variable Default severity: Failure Severity configurable: Yes Fault Timeout applicable: Yes Table 7-8: Extreme Primary Purpose Variable conditions Name Ignorable [005] Mass Flow Rate Overrange No [008] Density Overrange No Configuration and Use Manual 93 Configure device options and preferences May 2024 Configuration and Use Manual MS-00809-0200-1600 Function Check Failed or Smart Meter Verification Aborted Default severity: Maintenance Required Severity configurable: Yes Fault Timeout applicable: No Table 7-9: Function Check Failed or Smart Meter Verification Aborted conditions Name Ignorable [010] Calibration Failed No [034] Smart Meter Verification Failed Yes [035] Smart Meter Verification Aborted Yes Function Check in Progress Default severity: Function Check Severity configurable: No Fault Timeout applicable: No Table 7-10: Function Check in Progress conditions Name Ignorable [104] Calibration in Progress No [131] Smart Meter Verification in Progress Yes Output Fixed Default severity: Function Check Severity configurable: Yes Fault Timeout applicable: No Table 7-11: Output Fixed conditions Name Ignorable [111] Frequency Output Fixed No [118] Discrete Output Fixed No [101] mA Output Fixed No Output Saturated Default severity: Out of Speculation Severity configurable: Yes Fault Timeout applicable: No Table 7-12: Output Saturated conditions Name Ignorable [100] mA Output Saturated Yes [110] Frequency Output Saturated Yes Process Aberration Default severity: Out of Speculation 94 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure device options and preferences May 2024 Severity configurable: Yes Fault Timeout applicable: Yes Table 7-13: Process Aberration conditions Name Ignorable [105] Two-Phase Flow Yes [115] External Input Error Yes [116] Temperature Overrange (API Referral) Yes [117] Density Overrange (API Referral) Yes [121] Extrapolation Alert (Concentration) Yes [123] Pressure Overrange (API Referral) Yes Batch Time Out Yes Moderate Two-Phase Flow Yes Severe Two-Phase Flow Yes Security Breach Default severity: Failure Severity configurable: No Fault Timeout applicable: No Sensor Being Simulated Default severity: Function Check Severity configurable: No Fault Timeout applicable: No Table 7-14: Sensor Being Simulated conditions Name Ignorable [132] Sensor Simulation Active No Sensor Failed Default severity: Failure Severity configurable: No Fault Timeout applicable: Yes Table 7-15: Sensor Failed conditions Name Ignorable [003] Sensor Failed No [016] Sensor Temperature (RTD) Failure No [017] Sensor Case Temperature (RTD) Failure No Sensor-Transmitter Communication Error Default severity: Failure Severity configurable: No Fault Timeout applicable: Yes Configuration and Use Manual 95 Configure device options and preferences May 2024 Configuration and Use Manual MS-00809-0200-1600 Table 7-16: Sensor-Transmitter Communication Error conditions Name Ignorable [026] Sensor/Transmitter Communications Failure No [028] Core Process Write Failure No Transmitter Initializing Default severity: Failure Severity configurable: No Fault Timeout applicable: No Table 7-17: Transmitter Initializing conditions Name Ignorable [009] Transmitter Initializing/Warming Up No Tube Not Full Default severity: Failure Severity configurable: Yes Fault Timeout applicable: Yes Table 7-18: Tube Not Full conditions Name Ignorable [033] Insufficient Pickoff Signal Yes 96 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Integrate the meter with the control system May 2024 8 Integrate the meter with the control system 8.1 Channel configuration Display Menu → Configuration → Inputs/Outputs → Channel x ProLink III Device Tools → Configuration → I/O → Channels → Channel x Field communicator Device Settings → Inputs/Outputs → Channels 8.2 Configure I/O Channel A Channel A is ordered as mA/HART® or Modbus® RTU. Channel A cannot be changed after initial order. Signal Channel A Channel options mA/ HART(1) Modbus RTU(2) (1) If ordered with Hardware board code A. (2) If ordered with Hardware board code M. 8.3 Configure I/O Channel B Channel B is a configurable I/O channel. Channel B can be used for any of the following outputs: • Frequency Output • Discrete Output Prerequisites Important To avoid causing process errors: • The channel configuration must match the I/O wiring. • Before changing the channel configuration, ensure that all control loops affected by the channel are under manual control. Procedure 1. Set Channel Type as desired. 2. Power Source is Passive only. Option Description External (Passive) The channel is powered by an external power source. Configuration and Use Manual 97 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 Postrequisites Perform or verify the corresponding output or input configuration. When the configuration of a channel is changed, the channel's behavior will be controlled by the configuration that is stored for the selected input or output type, and the stored configuration may not be appropriate for your process. After verifying channel and output configuration, return the control loop to automatic control. 8.4 Configure an mA Output Use an mA Output to report current values of process variables. The mA signal varies between 4 mA and 20 mA in proportion to the current value of the assigned process variable. mA Output is only available if transmitter is ordered with Hardware Board code A. 8.4.1 Configure mA Output Source Display Menu → Configuration → Inputs/Outputs → I/O Settings → Source ProLink III Device Tools → Configuration → I/O → Channels → mA Output Field communicator Device Settings → Inputs/Outputs → mA Output x mA Output Source specifies the process variable that is reported by the mA Output. Prerequisites • If you plan to configure the output to report volume flow, ensure that you have set Volume Flow Type as desired: Liquid or Gas Standard Volume. • If you plan to configure an output to report a concentration measurement process variable, API Referral, or Advance Phase Measurement process variable, ensure that the concentration measurement application, API Referral, or Advance Phase Measurement application respectively, is configured so that the desired variable is available. Procedure Set mA Output Process Variable as desired. Default: Mass Flow Rate Postrequisites If you change the configuration of mA Output Source, verify the settings of Lower Range Value and Upper Range Value. The transmitter automatically loads a set of values, and these values may not be appropriate for your application. Options for mA Output Source The transmitter provides a basic set of options for mA Output Source, plus several application-specific options. Different communications tools may use different labels for the options. Process variable Label Display ProLink III Mass flow rate Mass Flow Rate Mass Flow Rate Volume flow rate Volume Flow Rate Volume Flow Rate Gas standard volume flow rate GSV Flow Rate Gas Standard Volume Flow Rate Temperature Temperature Temperature Standard 98 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Integrate the meter with the control system May 2024 Label Process variable Display ProLink III Density Density Density External pressure External Pressure External Pressure External temperature External Temperature External Temperature Velocity Velocity Velocity Two-phase flow detection Phase Phase Flow Severity Drive gain Drive Gain Drive Gain Temperature-corrected density Referred Density Density at Reference Temperature Temperature-corrected (standard) volume flow rate Referred Volume Flow Volume Flow Rate at Reference Temperature Diagnostics API Referral Average temperature-corrected density Average Line Density Average Density Average temperature Average Temperature Average Temperature Density at reference Referred Density Density at Reference Temperature Specific gravity Specific Gravity Density (Fixed SG Units) Standard volume flow rate Standard Vol Flow Volume Flow Rate at Reference Temperature Net mass flow rate Net Mass Flow Net Mass Flow Rate Net volume flow rate Net Volume Flow Rate Net Volume Flow Rate Concentration Concentration Concentration Baume Baume Baume Concentration measurement 8.4.2 Configure Lower Range Value (LRV) and Upper Range Value (URV) for an mA Output Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Lower Range Value Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Upper Range Value ProLink III Device Tools → Configuration → I/O → Outputs → mA Output → Lower Range Value Device Tools → Configuration → I/O → Outputs → mA Output → Upper Range Value Field communicator Device Settings → Inputs/Outputs → mA Output x → mAO x Settings → Lower Range Value Device Settings → Inputs/Outputs → mA Output x → mAO x Settings → Upper Range Value The Lower Range Value (LRV) and Upper Range Value (URV) are used to scale an mA Output, that is, to define the relationship between mA Output Process Variable and the mA Output signal. LRV is the value of mA Output Source represented by an output of 4 mA. URV is the value of mA Output Source represented by an output of 20 mA. Between LRV and URV, an mA Output is linear with the process variable. If the process variable drops below LRV or rises above URV, the transmitter posts an output saturation alert. Configuration and Use Manual 99 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 Procedure Set LRV and URV as desired. Enter LRV and URV in the measurement units used for mA Output Source. • Defaults: Specific to each process variable • Range: Unlimited Note You can set URV below LRV. For example, you can set URV to 50 and LRV to 100. If you do this, an mA Output will be inversely proportional to the value of mA Output Source. 8.4.3 Configure mA Output Direction Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Direction ProLink III Device Tools → Configuration → I/O → Outputs → mA Output → Direction Field communicator Device Settings → Inputs/Outputs → mA Output x → mAO x Direction mA Output Direction controls how conditions of forward flow and reverse flow affect the flow rates reported by an mA Output. Actual flow direction interacts with Sensor Flow Direction Arrow to determine the flow direction that the transmitter uses in processing. See the following table. Table 8-1: Interaction between actual flow direction and Sensor Flow Direction Arrow Setting of Sensor Flow Direction Arrow Flow direction sent to outputs and totalizers Forward (same direction as Flow arrow on sensor) With Arrow Forward Against Arrow Reverse Reverse (opposite from Flow arrow on sensor) With Arrow Reverse Against Arrow Forward Actual flow direction Procedure Set mA Output Direction as desired. Option Description Normal (default) Appropriate when your application needs to distinguish between forward flow and reverse flow. Absolute Value Appropriate when your application does not need to distinguish between forward flow and reverse flow. Important mA Output Direction interacts with Lower Range Value (LRV). The effect of mA Output Direction on an mA Output varies, depending on whether LRV < 0 or LRV ≥ 0. Related information Configure Sensor Flow Direction Arrow 100 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Integrate the meter with the control system May 2024 Effect of mA Output Direction on an mA Output mA Output Direction affects how the transmitter reports flow values via an mA Output. An mA Output is affected by mA Output Direction only if mA Output Source is set to a flow variable. The effect of mA Output Direction depends on the setting of Lower Range Value (LRV). • If Lower Range Value = 0, see Figure 8-1. • If Lower Range Value > 0, see Figure 8-1 and adapt the chart. • If Lower Range Value < 0, see Figure 8-2. Figure 8-1: Effect of mA Output Direction on an mA Output: Lower Range Value = 0 • Lower Range Value = 0 • Upper Range Value = x Configuration and Use Manual 101 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 Figure 8-2: Effect of mA Output Direction on an mA Output: Lower Range Value < 0 mA Output Direction = Absolute Value 20 20 12 12 mA output mA output mA Output Direction = Normal 4 -x 0 Reverse flow • Lower Range Value = −x • Upper Range Value = x 4 x Forward flow -x Reverse flow 0 x Forward flow Example: mA Output Direction = Normal and Lower Range Value = 0 Configuration: • mA Output Direction = Normal (default) • Lower Range Value = 0 g/sec • Upper Range Value = 100 g/sec Result: • Under conditions of reverse flow or zero flow, an mA Output is 4 mA. • Under conditions of forward flow, up to a flow rate of 100 g/sec, an mA Output varies between 4 mA and 20 mA in proportion to the flow rate. • Under conditions of forward flow, if the flow rate equals or exceeds 100 g/sec, an mA Output will be proportional to the flow rate up to 20.5 mA, and will be level at 20.5 mA at higher flow rates. 102 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Integrate the meter with the control system May 2024 Example: mA Output Direction = Normal and Lower Range Value < 0 Configuration: • mA Output Direction = Normal • Lower Range Value = −100 g/sec • Upper Range Value = +100 g/sec Result: • Under conditions of zero flow, an mA Output is 12 mA. • Under conditions of forward flow, for flow rates between 0 and +100 g/sec, an mA Output varies between 12 mA and 20 mA in proportion to (the absolute value of) the flow rate. • Under conditions of forward flow, if (the absolute value of) the flow rate equals or exceeds 100 g/sec, an mA Output is proportional to the flow rate up to 20.5 mA, and will be level at 20.5 mA at higher flow rates. • Under conditions of reverse flow, for flow rates between 0 and −100 g/sec, an mA Output varies between 4 mA and 12 mA in inverse proportion to the absolute value of the flow rate. • Under conditions of reverse flow, if the absolute value of the flow rate equals or exceeds 100 g/sec, an mA Output is inversely proportional to the flow rate down to 3.8 mA, and will be level at 3.8 mA at higher absolute values. 8.4.4 Configure mA Output Cutoff Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → MAO Cutoff ProLink III Device Tools → Configuration → I/O → Outputs → mA Output x → Flow Rate Cutoff Field communicator Device Settings → Inputs/Outputs → mA Output x → mAO x Settings → mA Output Flow Rate Cutoff mA Output Cutoff specifies the lowest flow rate that will be reported through an mA Output. All flow rates below the specified value are reported as 0. mA Output Cutoff is applicable only when mA Output Source is set to a flow rate variable. It is applied to whatever flow variable is assigned to an mA Output. Procedure Set mA Output Cutoff as desired. Set mA Output Cutoff in the measurement units used for the process variable. If you change the measurement unit, mA Output Cutoff is adjusted automatically. • Default: 0 • Range: 0 or any positive value Tip For most applications, the default value of mA Output Cutoff should be used. Contact customer service before changing mA Output Cutoff. Configuration and Use Manual 103 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 Interaction between mA Output Cutoff and process variable cutoffs When mA Output Process Variable is set to a flow variable (for example, mass flow rate or volume flow rate), mA Output Cutoff interacts with Mass Flow Cutoff or Volume Flow Cutoff. The transmitter puts the cutoff into effect at the highest flow rate at which a cutoff is applicable. 8.4.5 Configure mA Output Damping Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → MAO Damping ProLink III Device Tools → Configuration → I/O → Outputs → mA Output → Added Damping Field communicator Device Settings → Inputs/Outputs → mA Output x → mAO x Settings → Added Damping mA Output Damping controls the amount of damping that will be applied to the mA Output. Damping is used to smooth out small, rapid fluctuations in process measurement. The damping value specifies the time period, in seconds, over which the transmitter will spread changes in the process variable. At the end of the interval, the value reported by an mA Output will reflect 63% of the change in the actual measured value. mA Output Damping affects a process variable only when it is reported via the mA Output. If the process variable is read from the display or digitally, mA Output Damping is not applied. For most applications, leaving the mA Output Damping at 0.0 seconds should suffice. Change the Process Variable Damping first. Procedure Set mA Output Damping to the desired value. • Default: 0.0 seconds • Range: 0.0 to 440 seconds Tip • A high damping value makes the process variable appear smoother because the reported value changes slowly. • A low damping value makes the process variable appear more erratic because the reported value changes more quickly. • The combination of a high damping value and rapid, large changes in the process variable assigned to an mA Output can result in increased measurement error. • Whenever the damping value is non-zero, the damped value will lag the actual measurement because the damped value is being averaged over time. • In general, lower damping values are preferable because there is less chance of data loss, and less lag time between the actual measurement and the damped value. Interaction between mA Output Damping and process variable damping When mA Output Source is set to a flow rate variable, density, or temperature, mA Output Damping interacts with Flow Damping, Density Damping, or Temperature Damping. If multiple damping parameters are applicable, the effect of damping the process variable is calculated first, and the mA Output damping calculation is applied to the result of that calculation. Example: Damping interaction Configuration: • Flow Damping = 1 second • mA Output Source = Mass Flow Rate 104 Emerson.com Configuration and Use Manual MS-00809-0200-1600 • Integrate the meter with the control system May 2024 mA Output Damping = 2 seconds Result: A change in the mass flow rate will be reflected in the mA Output over a time period that is greater than 3 seconds. The exact time period is calculated by the transmitter according to internal algorithms which are not configurable. 8.4.6 Configure mA Output Fault Action Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Fault Action ProLink III Device Tools → Configuration → I/O → Outputs → mA Output x → Fault Action Field communicator Device Settings → Inputs/Outputs → mA Output x → mAO x Fault Settings mA Output Fault Action controls the behavior of the mA Output if the transmitter detects a fault condition. Important • The fault action is implemented only if Alert Severity is set to Failure. If Alert Severity is set to any other option, the fault action is not implemented. • For some faults only: If Fault Timeout is set to a non-zero value, the transmitter will not implement the fault action until the timeout has elapsed. Procedure 1. Set mA Output Fault Action as desired. Default: Downscale Important If you set mA Output Fault Action to None, the mA Output will be controlled by the setting of Process Variable Fault Action. In most cases, if you set mA Output Fault Action to None, you should also set Process Variable Fault Action to None. 2. If you set mA Output Fault Action to Upscale or Downscale, set mA Output Fault Level to the signal that the mA Output will produce during a fault. Options for mAO Fault Action and mAO Fault Level Option mA Output behavior mA Output Fault Level Upscale Goes to the configured fault level Default: 22.0 mA Range: 21.0 to 23.0 mA Downscale (default) Goes to the configured fault level Default: 2.0 mA Range: 1.0 to 3.6 mA Internal Zero Goes to the mA Output level associated with a process variable value of 0 (zero), as determined by Lower Range Value and Upper Range Value settings Not applicable None Determined by the setting of Process Variable Fault Action Not applicable Configuration and Use Manual 105 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 8.5 Configure a Frequency Output Use a Frequency Output to report current values of process variables. The frequency varies between 0 Hz and 12500 Hz in proportion to the current value of the assigned process variable. Maximum fault level is 14500 Hz. 8.5.1 Configure Frequency Output Source Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Type → Frequency Output ProLink III Device Tools → Configuration → I/O → Channels → Channel B → Frequency Output Field communicator Device Settings → Inputs/Outputs → Channels → Channel B Frequency Output Source specifies the process variable that is reported by the Frequency Output. Prerequisites • If you plan to configure the output to report volume flow, ensure that you have set Volume Flow Type as desired: Liquid or Gas Standard Volume. • If you plan to configure an output to report a concentration measurement process variable, ensure that the concentration measurement application is configured so that the desired variable is available. Procedure Set Frequency Output Source as desired. Postrequisites If you change the configuration of Frequency Output Source, verify the Frequency Output scaling. The transmitter automatically loads the most recent values for the scaling parameters, and they may not be appropriate for your application. Related information Configure Frequency Output Scaling Options for Frequency Output Source The transmitter provides a basic set of options for Frequency Output Source, plus several application-specific options. Different communications tools may use different labels for the options. Process variable Label Display PLIII Mass flow rate Mass Flow Rate Mass Flow Rate Volume flow rate Volume Flow Rate Volume Flow Rate Gas standard volume flow rate GSV Flow Rate Gas Standard Volume Flow Rate Referred Volume Flow Volume Flow Rate at Reference Temperature Standard volume flow rate Standard Vol Flow Volume Flow Rate at Reference Temperature Net mass flow rate Net Mass Flow Net Mass Flow Rate Standard API Referral Temperature-corrected (standard) volume flow rate Concentration measurement 106 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Integrate the meter with the control system May 2024 Label Process variable Net volume flow rate Display PLIII Net Volume Flow Rate Net Volume Flow Rate 8.5.2 Configure Frequency Output Scaling Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Scaling Method ProLink III Device Tools → Configuration → I/O → Outputs → Frequency Output → Scaling Method Field communicator Device Settings → Inputs/Outputs → Frequency Output x → FO x Scaling Frequency output scaling defines the relationship between Frequency Output Source and the pulse of the Frequency Output. Scale the Frequency Output to provide the data in the form required by your frequency receiving device. Procedure 1. Set Frequency Output Scaling Method. Option Description Frequency=Flow (default) Frequency calculated from flow rate Pulses/Unit A user-specified number of pulses represents one flow unit Units/Pulse A pulse represents a user-specified number of flow units 2. Set additional required parameters. • If you set Frequency Output Scaling Method to Frequency=Flow, set Rate Factor and Frequency Factor. • If you set Frequency Output Scaling Method to Pulses/Unit, define the number of pulses that will represent one flow unit. • If you set Frequency Output Scaling Method to Units/Pulse, define the number of units that each pulse will indicate. Calculate frequency from flow rate The Frequency=Flow option is used to customize the Frequency Output for your application when you do not know appropriate values for Units/Pulse or Pulses/Unit. If you specify Frequency=Flow, you must provide values for Rate Factor and Frequency Factor: Rate Factor The maximum flow rate that you want the Frequency Output to report. Frequency Factor A value calculated as follows: where: FrequencyFactor RateFactor × N T T Factor to convert selected time base to seconds N Number of pulses per flow unit, as configured in the receiving device The resulting Frequency Factor must be within the range of the Frequency Output : • If Frequency Factor is less than 1 Hz, reconfigure the receiving device for a higher pulses/unit setting. Configuration and Use Manual 107 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 Example: Configure Frequency=Flow You want the Frequency Output to report all flow rates up to 2000 kg/min. The frequency receiving device is configured for 10 pulses/kg. Solution: FrequencyFactor RateFactor × N T Set parameters as follows: • Rate Factor: 2000 • Frequency Factor: 333.33 FrequencyFactor 2000 × 10 60 FrequencyFactor = 333.33 8.5.3 Configure Frequency Output Direction Display Menu → Configuration → Inputs/Outputs → Channel x → I/O Settings → Direction ProLink III Device Tools → Configuration → I/O → Outputs → Frequency Output → Direction Field communicator Device Settings → Inputs/Outputs → Frequency Output x → FO x Direction Frequency Output Direction controls how conditions of forward flow and reverse flow affect the flow rates reported by the Frequency Output. Actual flow direction interacts with Sensor Flow Direction Arrow to determine the flow direction that the transmitter uses in processing. See the following table. Table 8-2: Interaction between actual flow direction and Sensor Flow Direction Arrow Setting of Sensor Flow Direction Arrow Flow direction sent to outputs and totalizers Forward (same direction as Flow arrow on sensor) With Arrow Forward Against Arrow Reverse Reverse (opposite from Flow arrow on sensor) With Arrow Reverse Against Arrow Forward Actual flow direction Procedure Set Frequency Output Direction as desired. Option Description Positive Flow Only • Forward flow: The Frequency Output reports the flow rate according to the configured scaling method. • Reverse flow: The Frequency Output is 0 Hz. • Forward flow: The Frequency Output is 0 Hz. • Reverse flow: The Frequency Output reports the absolute value of the flow rate according to the configured scaling method. Negative Flow Only 108 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Integrate the meter with the control system May 2024 Option Description Both Positive and Negative Flow The Frequency Output reports the absolute value of the flow rate according to the configured scaling method. It is not possible to distinguish between forward flow and reverse flow from the Frequency Output alone. This setting is typically used in combination with a discrete output configured to report flow direction. Related information Configure Sensor Flow Direction Arrow Configure Discrete Output Source 8.5.4 Configure Frequency Output Fault Action Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Fault Action ProLink III Device Tools → Configuration → I/O → Outputs → Frequency Output x → Fault Action Field communicator Device Settings → Inputs/Outputs → Frequency Output x → FO Mode Frequency Output Fault Action controls the behavior of the Frequency Output if the transmitter detects a fault condition. Important • The fault action is implemented only if Alert Severity is set to Failure. If Alert Severity is set to any other option, the fault action is not implemented. • For some faults only: If Fault Timeout is set to a non-zero value, the transmitter will not implement the fault action until the timeout has elapsed. Procedure 1. Set Frequency Output Fault Action as desired. Default: Downscale Important If you set Frequency Output Fault Action to None, the Frequency Output will be controlled by the setting of Process Variable Fault Action. In most cases, if you set Frequency Output Fault Action to None, you should also set Process Variable Fault Action to None. 2. If you set Frequency Output Fault Action to Upscale, set Frequency Fault Level to the desired value. • Default: 14500 Hz • Range: 10 Hz to 14500 Hz Related information Configure Process Variable Fault Action Options for Frequency Output Fault Action Label Frequency Output behavior Upscale Goes to configured Upscale value: • Default: 14500 Hz • Downscale Configuration and Use Manual Range: 10 Hz to 14500 Hz 0 Hz 109 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 Label Frequency Output behavior Internal Zero 0 Hz None (default) Determined by the setting of Process Variable Fault Action 8.6 Configure a Discrete Output Use a Discrete Output to report specific meter or process conditions. 8.6.1 Configure Discrete Output Source Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Source ProLink III Device Tools → Configuration → I/O → Channels → Channel B → Discrete Output Field communicator Device Settings → Inputs/Outputs → Mapping Source → Output Source → DO x Source Discrete Output Source specifies the process condition or device condition that is reported by a Discrete Output. Procedure Set Discrete Output Source to the desired option. Default: Forward/Reverse Postrequisites If you set Discrete Output Source to Flow Switch, additional configuration is required. Related information Configure Flow Rate Switch Options for Discrete Output Source Option Label State Discrete Output voltage ON Externally powered: Site-specific OFF 0 V ON Externally powered: Site-specific OFF 0 V ON Externally powered: Site-specific OFF 0 V Forward Reverse Indicator Forward flow 0 V Reverse flow Externally powered: Site-specific Calibration in Progress ON Externally powered: Site-specific OFF 0 V Fault Indication ON Externally powered: Site-specific OFF 0 V Display Prolink III Enhanced Event 1– 5 (1) Basic Event x Enhanced Event x Event 1–2 (2) Enhanced Event x Flow Rate Switch Flow Rate Switch Forward/Reverse Indicator Flow Direction Calibration in Progress Zero in Progress Fault Fault 110 Event x Flow Switch Indicator Emerson.com Configuration and Use Manual MS-00809-0200-1600 Option Integrate the meter with the control system May 2024 Label State Discrete Output voltage Meter Verification Failure(3) ON Externally powered: Site-specific OFF 0 V Batch Primary Valve ON Externally powered: Site-specific OFF 0 V Display Prolink III Smart Meter Verification Smart Meter Verification Batch Primary Valve Batch Primary Valve (1) Events configured using the enhanced event model. (2) Events configured using the basic event model. (3) The ProLink III v5.0 option is “Meter Verification Failure” for the Discrete Output Source field. This does match the table entry. Important This table assumes that Discrete Output Polarity is set to Active High. If Discrete Output Polarity is set to Active Low, reverse the voltage values. Important Actual flow direction interacts with Sensor Flow Direction Arrow to determine the flow direction that the transmitter uses in processing. See the following table. Table 8-3: Interaction between actual flow direction and Sensor Flow Direction Arrow Setting of Sensor Flow Direction Arrow Flow direction sent to outputs and totalizers Forward (same direction as Flow arrow on sensor) With Arrow Forward Against Arrow Reverse Reverse (opposite from Flow arrow on sensor) With Arrow Reverse Against Arrow Forward Actual flow direction 8.6.2 Configure Discrete Output Polarity Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Polarity ProLink III Device Tools → Configuration → I/O → Outputs → Discrete Output → Polarity Field communicator Device Settings → Inputs/Outputs → Discrete Output x → Discrete Output x → Polarity A Discrete Output has two states: ON (active, asserted) and OFF (inactive). Two different voltages are used to represent these states. Discrete Output Polarity controls which voltage represents which state. Procedure Set Discrete Output Polarity as desired. Default: Active High 8.6.3 Configure Discrete Output Fault Action Display Menu → Configuration → Inputs/Outputs → Channel B → I/O Settings → Fault Action ProLink III Device Tools → Configuration → I/O → Outputs → Discrete Output → Fault Action Field communicator Process Variables → Inputs/Outputs → Discrete Output x → Discrete Output x → Fault Action Configuration and Use Manual 111 Integrate the meter with the control system May 2024 Configuration and Use Manual MS-00809-0200-1600 Discrete Output Fault Action controls the behavior of a Discrete Output if the transmitter detects a fault condition. Important • The fault action is implemented only if Alert Severity is set to Failure. If Alert Severity is set to any other option, the fault action is not implemented. • For some faults only: If Fault Timeout is set to a non-zero value, the transmitter will not implement the fault action until the timeout has elapsed. NOTICE Do not use Discrete Output Source as a fault indicator. If you do, you may not be able to distinguish a fault condition from a normal operating condition. If you want to use the Discrete Output as a fault indicator, see Fault indication with a Discrete Output. Procedure Set Discrete Output Fault Action as desired. Default: None Related information Interaction between Process Variable Fault Action and other fault actions Options for Discrete Output Fault Action Label Upscale Downscale None (default) Discrete Output behavior Polarity=Active High Polarity=Active Low • Fault: Discrete Output is ON (site-specific voltage) • Fault: Discrete Output is OFF (0 V) • No fault: Discrete Output is controlled by its assignment • No fault: Discrete Output is controlled by its assignment • Fault: Discrete Output is OFF (0 V) • • No fault: Discrete Output is controlled by its assignment • Fault: Discrete Output is ON (site-specific voltage) No fault: Discrete Output is controlled by its assignment Discrete Output is controlled by its assignment Fault indication with a Discrete Output To indicate faults via a Discrete Output, set Discrete Output Source to Fault. Then, if a fault occurs, the Discrete Output is always ON and the setting of Discrete Output Fault Action is ignored. 112 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure digital communications May 2024 9 Configure digital communications 9.1 Configure HART® communications 9.1.1 Configure basic HART parameters Display Menu → Configuration → Time/Date/Tag ProLink III Device Tools → Configuration → Communications → Communications (HART) Field communicator Device Settings → Communications → HART → Communication Settings → Configure Communication → Device Basic HART parameters include the HART address, HART tags, and the operation of the primary mA output. This applies to transmitters ordered with Hardware Board code A. Procedure 1. Set HART Address to a value that is unique on your network. • Default: 0 • Range: 0 to 63 Tip • The default address is typically used unless you are a multidrop environment. • Devices using HART protocol to communicate with the transmitter may use either HART Address, HART Tag, or HART Long Tag to identify the transmitter. Configure any or all, as required by your other HART devices. 2. Set HART Tag to a value that is unique on your network. 3. Set HART Long Tag to a value that is unique on your network. HART Long Tag is supported only by HART 7. If you are using HART 5, you cannot use HART Long Tag to communicate with the transmitter. 4. Ensure that mA Output Action is configured appropriately. Option Description Enabled (Live) The primary mA output reports process data as configured. This is the appropriate setting for most applications. Disabled (Fixed) The primary mA output is fixed at 4 mA and does not report process data. Important If you use ProLink III to set HART Address to 0, the program automatically enables mA Output Action. If you use ProLink III to set HART Address to any other value, the program automatically disables mA Output Action. This is designed to make it easier to configure the transmitter for legacy behavior. Always verify mA Output Action after setting HART Address. Configuration and Use Manual 113 Configure digital communications May 2024 Configuration and Use Manual MS-00809-0200-1600 Configure HART® variables (PV, SV, TV, QV) Display Menu → Configuration → Inputs/Outputs → Channel A → HART Settings → HART Variables ProLink III Device Tools → Configuration → Communications → Communications (HART) → Variable Assignment Field communicator Device Settings → Inputs/Outputs → Mapping/Source → Variable Mapping The HART variables are a set of four variables predefined for HART use. The HART variables include the Primary Variable (PV), Secondary Variable (SV), Tertiary Variable (TV), and Quaternary Variable (QV). You can assign specific process variables to the HART variables, and then use standard HART methods to read or broadcast the assigned process data. The default HART variables are as follows: PV Mass Flow SV Density TV Volume Flow QV Temperature Note The Tertiary Variable and Quaternary Variable are also called the Third Variable (TV) and Fourth Variable (FV). Restriction The Primary Variable is always the process variable assigned to mA Output 1. If you change either of these assignments, the other is changed automatically. The Secondary Variable and Tertiary Variable are not tied to any outputs. This is different from previous Micro Motion Coriolis transmitters. Procedure Assign variables to the PV, SV, TV, and QV as desired. Options for HART variables Process variable PV SV TV QV Mass flow rate ✓ ✓ ✓ ✓ Volume flow rate ✓ ✓ ✓ ✓ Gas standard volume flow rate ✓ ✓ ✓ ✓ Temperature ✓ ✓ ✓ ✓ Density ✓ ✓ ✓ ✓ External pressure ✓ ✓ ✓ ✓ External temperature ✓ ✓ ✓ ✓ Current value of any totalizer ✓ ✓ ✓ Current value of any inventory ✓ ✓ ✓ ✓ ✓ ✓ Standard Totalizers and inventories Diagnostics Velocity 114 ✓ Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure digital communications May 2024 Process variable PV SV TV QV Drive gain ✓ ✓ ✓ ✓ Tube frequency ✓ ✓ ✓ Meter temperature ✓ ✓ ✓ Board temperature ✓ ✓ ✓ Inlet (LPO) amplitude ✓ ✓ ✓ Outlet (RPO) amplitude ✓ ✓ ✓ Live zero ✓ ✓ ✓ PV loop current ✓ ✓ ✓ % of range ✓ ✓ ✓ ✓ ✓ ✓ ✓ Temperature-corrected density ✓ ✓ ✓ ✓ Temperature-corrected (standard) volume flow rate ✓ ✓ ✓ ✓ Average temperature-corrected density ✓ ✓ ✓ ✓ Average temperature ✓ ✓ ✓ ✓ ✓ ✓ ✓ Two-phase flow severity API referral CTPL Concentration measurement Density at reference ✓ ✓ ✓ ✓ Specific gravity ✓ ✓ ✓ ✓ Standard volume flow rate ✓ ✓ ✓ ✓ Net mass flow rate ✓ ✓ ✓ ✓ Net volume flow rate ✓ ✓ ✓ ✓ Concentration ✓ ✓ ✓ ✓ Configure burst communications Burst mode is a mode of communication during which the transmitter regularly broadcasts HART® digital information to the network via the primary mA output. As a general rule, Burst mode should only be enabled if a triloop is being used. Configure HART burst messages Display Menu → Configuration → Inputs/Outputs → Channel A → HART Settings → Burst Message x ProLink III Device Tools → Configuration → Communications → Communications (HART) → Burst Mode Field communicator Device Settings → Communication → HART → Burst Configuration → Configure Burst Message Burst messages contain information on process variables or transmitter status. You can configure up to three burst messages. Each message can contain different information. Burst messages also provide the mechanism for trigger mode and event notification. Procedure 1. Navigate to the burst message you want to configure. Configuration and Use Manual 115 Configure digital communications May 2024 Configuration and Use Manual MS-00809-0200-1600 2. Enable the burst message. 3. Set Burst Option to the desired content. Table 9-1: Options for burst message contents HART command Label Description ProLink III Field communicator 1 Source (Primary Variable) Primary Variable The transmitter sends the primary variable (PV) in the configured measurement units in each burst message (e.g., 14.0 g/sec, 13.5 g/sec, 12.0 g/sec). 2 Primary Variable (Percent Range/Current) Pct Range/Current The transmitter sends the PV’s actual mA level and the PV’s percent of range in each burst message (e.g., 11.0 mA 25%). 3 Process Variables/Current Process Vars/Current The transmitter sends the PV’s actual milliamp reading and the PV, SV, TV, and QV values in measurement units in each burst message (e.g., 11.8 mA, 50 g/sec, 23 °C, 50 g/sec, 0.0023 g/cm3). 9 Read Device Variables with Status Device Variables with Status The transmitter sends up to eight user-specified process variables in each burst message. 33 Transmitter Variables Field Device Vars The transmitter sends four user-specified process variables in each burst message. 48 Read Additional Transmitter Status Read Additional Device Status The transmitter sends expanded device status information in each burst message. 4. Depending on your choice, select the four or eight user-specified variables for the burst message, or set the HART variables as desired. Configure HART trigger mode Display Menu → Configuration → Inputs/Outputs → Channel A → HART Settings → Burst Message x → Trigger Mode ProLink III Device Tools → Configuration → Communications → Communications (HART) → Trigger Mode Field communicator Device Settings → Communication → HART → Burst Configuration → View Message x → Configure Update Rate Trigger mode uses the burst message mechanism to indicate that a process variable has changed. When trigger mode is implemented, the bursting interval (HART update rate) changes if Primary Variable or Burst Variable 0 moves above or below the user-specified trigger level. You can set up a different trigger on each burst message. Prerequisites Before you can configure trigger mode, the corresponding HART burst message must be enabled. Procedure 1. Select the burst message for which you will set up trigger mode. 2. Set Trigger Mode to the type of trigger you want to use. Option Description Continuous The burst message is sent at Default Update Rate. The burst interval is not affected by changes in process variables. 116 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure digital communications May 2024 Option Description Falling • When the specified process variable is above Trigger Level, the burst message is sent at Default Update Rate. • When the specified process variable is below Trigger Level, the burst message is sent at Update Rate. • When the specified process variable is below Trigger Level, the burst message is sent at Default Update Rate. • When the specified process variable is above Trigger Level, the burst message is sent at Update Rate. Rising Windowed This option is used to communicate that the process variable is changing rapidly. Trigger Level defines a deadband around the most recently broadcast value. • If the process variable stays within this deadband, the burst message is sent at Default Update Rate. • On Change • • If the process variable moves outside this deadband in either direction, the burst message is sent at Update Rate. If any value in the burst message changes, the burst message is sent at Update Rate. If no values change, the burst message is sent at Default Update Rate. 3. Set Trigger Level to the value of the process variable at which the trigger will be activated. 4. Set Default Update Rate (or Base Burst Rate) to the burst interval to be used when the trigger is not active. 5. Set Update Rate (or Triggered Burst Rate) to the burst interval to be used when the trigger is active. 9.2 Configure Modbus communications Display Menu → Configuration → Inputs/Outputs → Channel A ProLink III Device Tools → Configuration → Communications → Communications (Modbus) Field Communicator Device Settings → Inputs/Outputs → Channels → Channel A Modbus communications parameters control Modbus communications with the transmitter. This applies to transmitters ordered with hardware board code M. Restriction If you need to configure all Modbus parameters, you must use ProLink III. The display does not provide access to Modbus ASCII Support or Additional Communications Response Delay. The Field Communicator provides access only to Modbus Address. Modbus support is implemented on the RS-485 physical layer via Channel A. Important Your device automatically accepts all connection requests within the following ranges: • Protocol: Modbus RTU (8-bit) or Modbus ASCII (7-bit) unless Modbus ASCII Support is disabled • Parity: none, odd, or even • Stop bits: 1 or 2 • Baud: 1200, 2400, 4800, 9600, 19200, 38400 Configuration and Use Manual 117 Configure digital communications May 2024 Configuration and Use Manual MS-00809-0200-1600 You do not need to configure these communications parameters on the device. Procedure 1. Enable or disable Modbus ASCII Support as desired. The setting of this parameter controls the range of valid Modbus addresses for your device. Modbus ASCII support Available Modbus addresses Disabled 1–127 Enabled 1–15, 32–47, 64–79, and 96–110 2. Set Modbus Address to a unique value on the network. Default Modbus address is 1. 3. Set Floating-Point Byte Order to match the byte order used by your Modbus host. Code Byte order 0 1–2 3–4 1 3–4 1–2 2 2–1 4–3 3 4–3 2–1 Note The default byte order is 1. See the following table for the bit structure of bytes 1, 2, 3, and 4. Table 9-2: Bit structure of floating-point bytes Byte Bits Definition 1 SEEEEEEE S=Sign E=Exponent 2 EMMMMMMM E=Exponent M=Mantissa 3–4 MMMMMMMM M=Mantissa 4. Set Double-Precision Byte Order to match the byte order used by your Modbus host. 118 Code Byte order 0 1–2–3–4 5–6–7–8 1 3–4–1–2 7–8–5–6 2 2–1–4–3 6–5–8–7 3 4–3–2–1 8–7–6–5 4 5–6–7–8 1–2–3–4 5 7–8–5–6 3–4–1–2 6 6–5–8–7 2–1–4–3 7 8–7–6–5 4–3–2–1 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Configure digital communications May 2024 Note The default byte order is 1. See the following table for the bit structure of bytes 1–8. Table 9-3: Bit structure of double-precision bytes Byte Bits Definition 1 SEEEEEEE S=Sign E=Exponent 2 EEEEMMMM E=Exponent M=Mantissa 3–8 MMMMMMMM M=Mantissa 5. Optional: Set Additional Communications Response Delay in delay units. A delay unit is ⅔ of the time required to transmit one character, as calculated for the port currently in use and the character transmission parameters. Additional Communications Response Delay is used to synchronize Modbus communications with hosts that operate at a slower speed than the device. The value specified here will be added to each response the device sends to the host. • Default: 0 • Range: 0 to 255 Tip Do not set Additional Communications Response Delay unless required by your Modbus host. Configuration and Use Manual 119 Configure digital communications May 2024 120 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Complete the configuration May 2024 10 Complete the configuration 10.1 Test or tune the system using sensor simulation Display Menu → Service Tools → Sensor Simulation → Simulate Sensor ProLink III Device Tools → Diagnostics → Testing → Sensor Simulation Field communicator Diagnostics → Simulation → Simulate Sensor Use sensor simulation to test the system's response to a variety of process conditions, including boundary conditions, problem conditions, or alert conditions, or to tune the loop. Restriction Sensor simulation is available only on flow meters with the enhanced core processor. Prerequisites Before enabling sensor simulation, ensure that your process can tolerate the effects of the simulated process values. Procedure 1. Enable sensor simulation. 2. For mass flow, set Wave Form as desired and enter the required values. Option Required values Fixed Fixed Value Sawtooth Period Minimum Maximum Sine Period Minimum Maximum 3. For density, set Wave Form as desired and enter the required values. Option Required values Fixed Fixed Value Sawtooth Period Minimum Maximum Sine Period Minimum Maximum Configuration and Use Manual 121 Complete the configuration May 2024 Configuration and Use Manual MS-00809-0200-1600 4. For temperature, set Wave Form as desired and enter the required values. Option Required values Fixed Fixed Value Sawtooth Period Minimum Maximum Sine Period Minimum Maximum 5. Observe the system response to the simulated values and make any appropriate changes to the transmitter configuration or to the system. 6. Modify the simulated values and repeat. 7. When you have finished testing or tuning, disable sensor simulation. 10.1.1 Sensor simulation Sensor simulation allows you to test the system or tune the loop without having to create the test conditions in your process. When sensor simulation is enabled, the transmitter reports the simulated values for mass flow, density, and temperature, and takes all appropriate actions. For example, the transmitter might apply a cutoff, activate an event, or post an alert. When sensor simulation is enabled, the simulated values are stored in the same memory locations used for process data from the sensor. The simulated values are then used throughout transmitter functioning. For example, sensor simulation will affect: • All mass flow rate, temperature, and density values displayed or reported via outputs or digital communications • The mass total and mass inventory values • All volume calculations and data, including reported values, volume totals, and volume inventories • All mass, temperature, density, or volume values logged to Data Logger Sensor simulation does not affect any diagnostic values. Unlike actual mass flow rate and density values, the simulated values are not temperature-compensated (adjusted for the effect of temperature on the sensor’s flow tubes). 10.2 Enable or disable write-protection Upper puck Use the mechanical switch on the upper puck. ProLink III Device Tools → Configuration → Write-Protection When enabled, Write-Protection prevents changes to the transmitter configuration. You can perform all other functions, and you can view the transmitter configuration parameters. Note Write protection is available only by removing the display in order to access the upper puck component and using the lock switch to set the switch ON. 122 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Complete the configuration May 2024 Figure 10-1: Removing the transmitter housing cover A. Display Component B. Upper Puck Component Configuration and Use Manual 123 Complete the configuration May 2024 Configuration and Use Manual MS-00809-0200-1600 Figure 10-2: Setting Switch 1 ON (to the left) to Set Write-Protection A. Switch 1 Write-protecting the transmitter primarily prevents accidental changes to configuration, not intentional changes. Any user who can make changes to the configuration can disable write protection. 124 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Transmitter operation May 2024 11 Transmitter operation 11.1 View process and diagnostic variables Process variables provide information about the state of the process fluid. Diagnostic variables provide data about device operation. You can use this data to monitor and troubleshoot your process. 11.1.1 View process and diagnostic variables using the display The display reports the name of the variable (for example, Density), the current value of the variable, and the associated unit of measure (for example, kg/m3). Prerequisites For a process or diagnostic variable to be viewed using the display, it must be configured as a display variable. Procedure • If Auto Scroll is not enabled, activate ⇩ or ⇧ to move through the list of display variables. • If Auto Scroll is enabled, wait until the variable is displayed automatically. If you do not want to wait, you can activate ⇩ or ⇧ to force the display to scroll. 11.1.2 View process variables and other data using ProLink III Monitor process variables, diagnostic variables, and other data to maintain process quality. ProLink III automatically displays process variables, diagnostic variables, and other data on the main screen. Tip ProLink III allows you to choose the process variables that appear on the main screen. You can also choose whether to view data in Analog Gauge view or digital view, and you can customize the gauge settings. For more information, see the ProLink III with ProcessViz Software User Manual. 11.1.3 View process variables and other data using a field communicator Monitor process variables, diagnostic variables, and other data to maintain process quality. Procedure • To view current values of basic process variables, choose Overview. • To view a more complete set of process variables, plus the current state of the outputs, choose Service Tools → Variables. • To view diagnostic variables, choose Service Tools → Maintenance → Diagnostic Variables. 11.1.4 Effect of Sensor Flow Direction Arrow on digital communications Flow rates on the transmitter display or reported via digital communications are shown as positive or negative. The sign depends on the interaction between Sensor Flow Direction Arrow and the actual flow direction. This interaction affects flow rates shown on the transmitter display, ProLink III, and all other user interfaces. Configuration and Use Manual 125 Transmitter operation May 2024 Configuration and Use Manual MS-00809-0200-1600 Flow rate value Setting of Sensor Flow Direction Arrow Transmitter display Digital communications Forward (same direction as Flow arrow on sensor) With Arrow Positive (no sign) Positive Against Arrow Negative Negative Reverse (opposite from Flow arrow on sensor) With Arrow Negative Negative Against Arrow Positive (no sign) Positive Actual flow direction 11.2 View and acknowledge status alerts The transmitter posts a status alert whenever one of the specified conditions occurs. You can view active alerts and you can acknowledge alerts. You do not have to acknowledge alerts. The transmitter will perform normal measurement and reporting functions with unacknowledged alerts. 11.2.1 View and acknowledge alerts using the display You can view information about all active or unacknowledged alerts, and you can acknowledge alerts. The display uses the alert banner and the alert symbol ⓘ to provide information about alerts. Table 11-1: Alert information on display Display status Cause User action Alert banner One or more alerts are active. Resolve the conditions to clear the alert. When the alert is cleared or acknowledged, the banner will be removed. Alert symbol ⓘ One or more alerts are unacknowledged. Acknowledge the alert. When all alerts are acknowledged, the alert icon will be removed. If alert security is enabled, the alert banner is never displayed. To view detailed information, you must use the alert menu: Menu → (i) Alert List. Note Certain alerts do not clear until the transmitter is rebooted. Procedure • If the alert banner appears: a) Activate Info to view information about the alert. b) Take appropriate steps to clear the alert. c) Activate Ack to acknowledge the alert. • If ⓘ appears: a) Choose Menu → (i) Alert List. b) Select an alert to view more information about the specific alert or to acknowledge it individually. c) Choose Acknowledge All Alerts to acknowledge all alerts on the list. 126 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Transmitter operation May 2024 11.2.2 View and acknowledge alerts using ProLink III You can view a list containing all alerts that are active, or inactive but unacknowledged. From this list, you can acknowledge individual alerts or choose to acknowledge all alerts at once. Note Certain alerts do not clear until the transmitter is rebooted. Procedure 1. View alerts on the ProLink III main screen under Alerts. All active or unacknowledged alerts are listed. Take appropriate steps to clear all active alerts. 2. To acknowledge a single alert, check the Ack check box for that alert. To acknowledge all alerts at once, select Ack All. 11.2.3 View alerts using a field communicator You can view a list containing all alerts that are active, or inactive but unacknowledged. Restriction You cannot use a field communicator to acknowledge alerts. You can only view alerts. To acknowledge alerts, use the display or make a connection to the transmitter using a different tool. Procedure • To view active or unacknowledged alerts, choose Service Tools → Alerts. All active alerts and unacknowledged alerts are listed. Select an alert to view detailed information. • To refresh the list, choose Service Tools → Alerts → Refresh Alerts. 11.3 Read totalizer and inventory values Display Menu → Operations → Totalizers → See Totals ProLink III Device Tools → Totalizer Control → Totalizers Device Tools → Totalizer Control → Inventories Field communicator Process Variables → Device Overview → State & Tasks → Totalizer Control Totalizers keep track of the total amount of mass or volume measured by the transmitter since the last totalizer reset. Inventories keep track of the total amount of mass or volume measured by the transmitter since the last inventory reset. 11.4 Start, stop, and reset totalizers and inventories When a totalizer or inventory is started, its value increases or decreases depending on the interaction of the flow direction parameters. It continues tracking flow until it is stopped. When a totalizer or inventory is reset, its value is set to 0. You can reset a totalizer or inventory while it is started or while it is stopped. • You can start, stop, or reset each totalizer or inventory independently. • You can start, stop, or reset all totalizers and inventories as a group. Configuration and Use Manual 127 Transmitter operation May 2024 Configuration and Use Manual MS-00809-0200-1600 11.4.1 Start, stop, and reset totalizers using the display Prerequisites To stop, start, or reset a single totalizer or inventory, the totalizer or inventory must be configured as a display variable. To reset an inventory using the display, this function must be enabled. To enable inventory reset using the display, choose Menu → Configuration → Security → Display Security → Totalizers & Inventories → Inventory Reset and set Totalizer Reset to Allowed and save. Note that this affects only the display functions. Resetting inventories using other tools is not affected. Procedure • To start or stop a single totalizer or inventory: a) Wait or scroll until the totalizer or inventory appears on the display. b) Choose Options. c) Choose Start or Stop. • To start or stop all totalizers and inventories as a group: a) Choose Menu → Operations → Totalizers. b) Choose Start or Stop. • To reset a single totalizer or inventory: a) Wait or scroll until the totalizer or inventory appears on the display. b) Choose Options. c) Choose Reset. • To reset all totalizers and inventories as a group: a) Choose Menu → Operations → Totalizers. b) Choose Reset All. 11.4.2 Start, stop, and reset totalizers using ProLink III Prerequisites To reset an inventory using ProLink III, this function must be enabled. To enable inventory reset using ProLink III, choose Tools → Options and enable Reset Inventories from ProLink III. Note that this affects only ProLink III. Resetting inventories using other tools is not affected. Procedure • To start or stop a single totalizer: a) Choose Device Tools → Totalizer Control → Totalizers. b) Scroll to the totalizer that you want to start or stop, and click Start or Stop. • To start or stop a single inventory: a) Choose Device Tools → Totalizer Control → Inventories. b) Scroll to the inventory that you want to start or stop, and click Start or Stop. • To start or stop all totalizers as a group: a) Choose Device Tools → Totalizer Control → Totalizers or Device Tools → Totalizer Control → Inventories. b) Select Start All Totals or Stop All Totals. 128 Emerson.com Configuration and Use Manual MS-00809-0200-1600 • Transmitter operation May 2024 To reset a single totalizer: a) Choose Device Tools → Totalizer Control → Totalizers. b) Scroll to the totalizer that you want to reset, and click Reset. • To reset a single inventory: a) Choose Device Tools → Totalizer Control → Inventories. b) Scroll to the inventory that you want to reset, and click Reset. • To reset all totalizers as a group: a) Choose Device Tools → Totalizer Control → Totalizers. b) Select Reset All Totals. • To reset all inventories as a group: a) Choose Device Tools → Totalizer Control → Inventories. b) Select Reset All Inventories. Configuration and Use Manual 129 Transmitter operation May 2024 130 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Operation using the batcher May 2024 12 Operation using the batcher 12.1 Run a batch You can run a batch using any of the presets that are enabled. You can change the target for the current batch. You can pause and resume a batch in process. You can allow the batch to complete normally or you can end it manually. Restriction You cannot use a field communicator to run a batch. Prerequisites The preset that you want to use must be enabled. Procedure 1. Select the preset you want to use. Option Description Display Choose Menu → Batcher → Run Batch and set Active Preset to the preset you want to use. ProLink III Choose Device Tools → Configuration → Batcher and set Current Preset Number to the preset you want to use. Field communicator Not available The preset contains parameters that control batch processing. 2. If desired, change the configured target to the target to be used for this batch only. Option Description Display Choose Current Preset Number to the preset you want to use, and set Batch Target to the desired value. ProLink III Choose Device Tools → Application Control → Run Batcher and set Current Target to the desired value. Field communicator Not available You cannot set the target to a value that is greater than the Maximum Target value configured for the batching application. Changing the target here does not change the target configured in the preset. Configuration and Use Manual 131 Operation using the batcher May 2024 Configuration and Use Manual MS-00809-0200-1600 3. Begin the batch. Option Description Display Choose Menu → Batcher → Run Batch → Batch Control and select Begin. ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and select Begin Batch. Field communicator Not available The transmitter automatically resets the batch total to 0 if you have selected Reset on Start. Otherwise, you must manually reset the batch total before the batch will start. 4. Monitor the batch during processing. Option Description Display Choose Menu → Batcher → Run Batch and observe the value displayed in Batch Total. ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and observe the values displayed in Current Total and Batch Time. Field communicator Not available 5. Optional: Pause the batch at any time. Option Description Display Choose Menu → Batcher → Run Batch → Batch Control and select Pause. ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and select Pause Batch. Field communicator Not available Pausing a batch allows you to resume it later. 6. Optional: Resume the batch after it has been paused. Option Description Display Choose Menu → Batcher → Run Batch → Batch Control and select Resume. ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and select Resume Batch. Field communicator Not available 132 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Operation using the batcher May 2024 7. Optional: End the batch manually at any time before it reaches the target. Option Description Display Choose Menu → Batcher → Run Batch → Batch Control and select End. ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and select End Batch. Field communicator Not available If you end a batch manually, you will not be able to resume it. You can end the batch while it is running and while it is paused. 8. If you did not end the batch manually, wait until the batch ends automatically. The batch ends automatically when it reaches the target or when it reaches the configured maximum fill time. 9. Optional: Inhibit batch. Option Description Display Not available ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and set Inhibit Batch Start to On or Off. Field communicator Not available While the Inhibit Batch input is active, a batch will not be allowed to start. Attempting to start a batch while the batch is inhibited will cause the Start Not Okay alarm to be posted. 10. Optional: Inhibit totalizer. Option Description Display Not available ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and set Inhibit Batch Totalizing to On or Off. Field communicator Not available When the Inhibit Totalizer input is active, the Batch Total will not increment. A timeout alarm will occur if the Batch Total is inhibited beyond the max batch time. The batch inventory for the current preset will not increment while Inhibit Totalizer is active. 11. Optional: Inhibit flow. Option Description Display Not available ProLink III Choose Device Tools → Application Control → Batching → Run Batcher and set Allow Batch End with Flow to On or Off. Field communicator Not available When the Inhibit Flow input is active, the batch will ignore the flow rate of the assigned flow source, allowing a batch to end. The batch total will not increment when flow is inhibited. Configuration and Use Manual 133 Operation using the batcher May 2024 Configuration and Use Manual MS-00809-0200-1600 12.2 Perform AOC calibration AOC calibration “trains” the AOC algorithm to adjust for your network speed and valve closure speed. AOC calibration is required only if AOC Compensation Mode is set to AOC Algorithm. There are two options for AOC calibration: • Calculate and save: When you are satisfied with the results of AOC calibration, you can save the current AOC coefficient. It will be used for all batches. • Rolling calibration: The AOC coefficient is recalculated for each batch, based on the results of the most recent batches. Prerequisites Compensation Mode must be set to AOC. AOC only functions when the discrete output is assigned to Primary Valve and is opening and closing an actual valve. 12.2.1 Perform AOC calibration using the display Procedure • To calculate and save an AOC coefficient: a) Choose Menu → Batcher → AOC Calibration. b) Set AOC Cal Status to On. c) Run several batches, allowing each batch to run to completion, and observe the totals. d) When batch repeatability meets requirements, set AOC Cal Status to Off. AOC calibration is stopped, and the current coefficient is saved. Important If you are using a saved value, repeat AOC calibration: — Whenever the fluid characteristics change, especially viscosity — Whenever you change any configuration parameter that can affect flow measurement (e.g., damping) • To set up rolling calibration: a) Choose Menu → Operations → Batcher → AOC Calibration. b) Set AOC Window to the number of batches that the rolling AOC coefficient will be based on. c) Set AOC Cal Status to On. Important If you are using rolling calibration, and fluid characteristics change or the transmitter configuration changes, the transmitter will automatically adjust to the new conditions after a few batches. 12.2.2 Perform AOC calibration using ProLink III Procedure • To calculate and save an AOC coefficient: a) Choose Device Tools → Application Control → Batcher → Run Batcher. b) Click Start AOC Calibration. c) Run several batches, allowing each batch to run to completion, and observe the totals. To set up rolling calibration, choose Device Tools → Application Control → Batching → Run Batcher. 134 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Operation using the batcher May 2024 d) When batch repeatability meets requirements, click Save AOC Calibration. AOC calibration is stopped, and the current coefficient is saved. Important If you are using a saved value, repeat AOC calibration: — Whenever the fluid characteristics change, especially viscosity — Whenever you change any configuration parameter that can affect flow measurement (e.g., damping) • To set up rolling calibration: a) Choose Device Tools → Configuration → Batcher. b) Set AOC Window Length to the number of batches that the rolling AOC coefficient will be based on. c) Choose Device Tools → Application Control → Run Batcher. d) Click Start AOC Calibration. Important If you are using rolling calibration, and fluid characteristics change or the transmitter configuration changes, the transmitter will automatically adjust to the new conditions after a few batches. Configuration and Use Manual 135 Operation using the batcher May 2024 136 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 13 Measurement support 13.1 Use Smart Meter Verification Smart Meter Verification (SMV) provides in-process flow meter health verification by analyzing the meter components related to measurement performance. You can run Smart Meter Verification without stopping the process. Use this section to run a Smart Meter Verification test, view and interpret the results, set up automatic execution, and check if a field reference point has been established. 13.1.1 Smart Meter Verification capabilities Basic Professional Included 90-day trial, licensed Calibration coefficients audit ● ● Zero audit ● ● Electronics verification ● ● Automatic test scheduler ● ● History of previous 20 results ● ● Capability Verification report ●(1) (1) Create and export with ProLink III, or AMS SNAP-ON. 13.1.2 Setting the field reference point using the display Prerequisites Read the Smart Meter Verification prerequisites in Use Smart Meter Verification. Procedure Choose Menu → Operations → Smart Meter Verification → Set Field Reference Point. 13.1.3 Setting the field reference point using the ProLink III Prerequisites Read the Smart Meter Verification prerequisites in Use Smart Meter Verification. Procedure Choose Device Tools → Diagnostics → Meter Verification → Set Field Reference Point. Important Ensure the meter is full of single-phase fluid at normal operating conditions before establishing the Reference Point. If the Field Reference Point was not run at operating conditions, it may not be appropriate for the process. NOTICE Do not overwrite an existing Field Reference Point if the meter has been installed for a long period of time, or if there is a chance of corrosion, erosion, or other tube damage. Configuration and Use Manual 137 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 13.1.4 Run a Smart Meter Verification test Run a Smart Meter Verification Basic or Professional test to diagnose the flow meter (and flow meter system) and verify if the flow meter is functioning properly and performing within factory specifications. Important Run the first Smart Meter Verification Basic or Professional test when the flow meter is installed in the pipeline and the flow meter is at its normal operating conditions. Run a Smart Meter Verification test using the display Prerequisites Read the Smart Meter Verification prerequisites in Use Smart Meter Verification. Procedure 1. Choose Menu → Operations → Smart Meter Verification → Run Verification. 2. Select the desired output behavior. Option Description Continue Measuring During the test, all outputs will continue to report their assigned process variables. The test will run for approximately 90 seconds. Fix at Last Measured Value During the test, all outputs will report the last measured value of their assigned process variable. The test will run for approximately 140 seconds. Fix at Fault During the test, all outputs will go to their configured fault action. The test will run for approximately 140 seconds. The test starts immediately. 3. Wait for the test to complete. Note At any time during the process, you can abort the test. If the outputs were fixed, they will return to normal behavior. Run a Smart Meter Verification test using ProLink III Basic or Professional Procedure 1. Read the Smart Meter Verification prerequisites in Use Smart Meter Verification if you have not done so already. 2. Run Smart Meter Verification Basic or Professional using ProLink III Basic or Professional: • Smart Meter Verification Basic: Device Tools → Diagnostics → Meter Verification → Basic Meter Verification • Smart Meter Verification Professional: Smart Meter Verification Overview → Meter Verification → Run Verification • Smart Meter Verification Professional: Device Tools → Diagnostics → Meter Verification → Run Test 3. In the SMV Test Definition window, enter any desired information and click Next. None of this information is required. It does not affect Smart Meter Verification processing. ProLink III stores this information in the Smart Meter Verification database on the PC. It is not saved to the transmitter. 138 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 4. Select the desired output behavior. Option Description Continue Measuring During the test, all outputs will continue to report their assigned process variables. The test will run for approximately 90 seconds. Fix at Last Measured Value During the test, all outputs will report the last measured value of their assigned process variable. The test will run for approximately 140 seconds. Fix at Fault During the test, all outputs will go to their configured fault action. The test will run for approximately 140 seconds. 5. Select Start and wait for the test to complete. Note At any time during the process, you can abort the test. If the outputs were fixed, they will return to normal behavior. Run a Smart Meter Verification test using a field communicator Field communicator Device Settings → Calibration → Smart Meter Verification → Manual Verification → Start Procedure 1. Read the Smart Meter Verification prerequisites in Use Smart Meter Verification if you have not done so already. 2. Select the desired output behavior. Option Description Continue Measuring During the test, all outputs will continue to report their assigned process variables. The test will run for approximately 90 seconds. Fix at Last Measured Value During the test, all outputs will report the last measured value of their assigned process variable. The test will run for approximately 140 seconds. Fix at Fault During the test, all outputs will go to their configured fault action. The test will run for approximately 140 seconds. The test starts immediately. 3. Wait for the test to complete. Note At any time during the process, you can abort the test. If the outputs were fixed, they will return to normal behavior. Run a Smart Meter Verification test from a Modbus host Prerequisites The Modbus host must be connected to the transmitter. Procedure 1. Read the Smart Meter Verification prerequisites in Use Smart Meter Verification if you have not done so already. 2. If you are fixing outputs during the test, set the output state from Register 3093. Configuration and Use Manual 139 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 Option Description 0 Last Measured Value 1 Fault Action 3. From Register 3000, write a 6 to start DMV or a 5 to abort it. 4. Read Register 3020. Is the test running? Option Description > 0 = Yes Read the percent complete from Register 3020. Range: 0 to 100 0 = No Continue to the next step. 5. Read Register 3000. Did the test run to completion? Option Description 0 = Yes Continue to the next step. > 0 = No Read the abort code on Register 3002. 2 = SMV timeout — check status of pickoff and drive coils 3 = Pickoff voltage low — check status of pickoff and drive coils 4 = Temperature unstable — verify that the temperature is stable and start again 7 = Drive loop AGC reported an amplitude error — check status of pickoff and drive coils 8 = High flow (dt) standard deviation — reduce flow rate and start again 9 = High flow (dt) mean value — reduce flow rate and start again 12 = Transmitter in fault — clear alarms before proceeding 13 = No factory air verification — perform factory calibration on air 14 = No factory water verification — perform factory calibration on water 15 = Drive frequency drift from carrier frequency — ensure temperature, flow, and density are stable and start again 6. Read Register 3004. Has the test passed? 0 = Yes The test has passed. > 0 = No The test has not passed. Continue to the next step. 7. Read Register 6348. 140 256 Possible extreme temperature or corrosion 512 Possible extreme temperature or damage 2048 Possible corrosion/erosion Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 13.1.5 View Smart Meter Verification test results When the Smart Meter Verification Basic test is complete, a pass/fail result is displayed. With Smart Meter Verification Professional, detailed results and reports are available. Note With Smart Meter Verification Professional, the twenty most recent results are available. If viewed using ProLink III Basic or Professional, results for all tests that are in the PC database are available. View Smart Meter Verification test results using the display Results of the current Smart Meter Verification Basic or Professional test display automatically after the test is complete. With Smart Meter Verification Professional, use the following procedure to view previous test results. Procedure 1. Choose Menu → Operations → Smart Meter Verification → Read Verification History. 2. To view Pass/Fail status time and date for an individual test, select it from the list. View Smart Meter Verification test results using ProLink III Basic or Professional Results of the current Smart Meter Verification Basic or Professional test display automatically after the test is complete. With Smart Meter Verification Professional, use the following procedure to view previous test results. All Smart Meter Verification test results are stored on the same PC that Smart Meter Verification was initiated from. To view a previous test report, the Smart Meter Verification Professional test must have been run on that same PC. Procedure 1. Choose one of the following options: • Device Tools → Diagnostics → Meter Verification → Run Test → View Previous Test Results • Smart Meter Verification Overview → Meter Verification → History 2. To view details, choose the results of interest: Show Report (or Next to show the report). ProLink III displays a report containing details of the most recent tests. The report is automatically saved to the Smart Meter Verification database. You can print or export the report. View Smart Meter Verification test results using a field communicator In addition to test results, some field communicator brands provide a trend chart. Results of the current Smart Meter Verification Basic or Professional test display automatically after the test is complete. With Smart Meter Verification Professional, use the following procedure to view previous test results. Procedure 1. Choose Device Settings → Calibration → Smart Meter Verification → Manual Verification. 2. Choose Upload Results Data from Device. The field communicator stores only the most recent test result. To view earlier results, you must upload them from the device. They will be available only for the current session. 3. Choose Show Results Table. The field communicator displays detailed results for the first test. Configuration and Use Manual 141 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 4. Press OK to move through all test records in the local database. View Smart Meter Verification test results from a Modbus host Prerequisites To read test results, the Modbus host must be connected to the transmitter. Procedure 1. Specify the test record you want to read by writing a value between 0 and 19 to the appropriate register. Register Description 5779 Register 5825 = the most recent test 2. Read the Modbus register values using the descriptions in the following table. Registers Description 5697 Test number 5820 and 5821 Test result 5819 State 5818 Abort code (compressed) 5780 Time initiated 5782 and 5783 Inlet normalized data 5784 and 5785 Outlet normalized data 0 = Pass 1 = Caution 3. Disconnect as desired. Interpreting Smart Meter Verification results When the Smart Meter Verification Basic or Professional test is completed, the result is reported as Pass, Fail, or Abort. (Some tools report the Fail result as Advisory instead.) Pass The meter is performing within factory specifications. Abort When you execute a Smart Meter Verification Basic or Professional test, the test performs a self- diagnostic check to ensure that the flow meter is stable prior to running the test. In the rare case that this check reveals an issue, Smart Meter Verification will report an abort code. If you manually cancel an in-process Smart Meter Verification Basic or Professional test, the test result displays Abort Code 1: User-Initiated Abort. In this case, you can restart Smart Meter Verification without any further action. In the rare case any other abort occurs, contact factory support. In all cases where a Smart Meter Verification Professional test aborts, no report will be generated. Fail 142 If a Smart Meter Verification Basic or Professional test ran at normal operations and failed, see Resolve a failed Smart Meter Verification test to determine the appropriate actions. Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 13.1.6 Resolve a failed Smart Meter Verification test Use this procedure if a Smart Meter Verification Basic or Professional test ran at normal operating conditions while conditions were stable and failed. Procedure 1. Verify the sensor by performing a visual inspection, density verification, or field proving. 2. If possible, run Smart Meter Verification Professional with ProLink III Basic or Professional and save the results as follows: • In a .csv file • In a report • If the transmitter has a historian, retrieve the Smart Meter Verification results from the service or historian files. 3. Contact the factory for further evaluation and instructions. 13.1.7 Set up Smart Meter Verification automatic execution You can execute a Smart Meter Verification Basic or Professional test on demand or automatically schedule future runs. You can schedule future runs via two different options: as a single test at a user-defined future time, or automatically on a regular schedule. Tip The time between test runs must be between 1 and 1000 hours. The time for the first test run can be any positive floating number. Set up Smart Meter Verification automatic execution using the display Procedure 1. Choose Menu → Operations → Smart Meter Verification → Schedule Verification. 2. To schedule a single test: a) Set Hours to 1st Run to the number of hours to elapse before the test is run. b) Set Hours Between to 0. 3. To schedule a recurring execution: a) Set Hours Between to the number of hours between recurring runs. 4. To disable scheduled execution: a) Set Hours to 1st Run to 0. b) Set Hours Between to 0. Configuration and Use Manual 143 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 Set up Smart Meter Verification automatic execution using ProLink III Basic or Professional Procedure 1. Select one of the following paths to access the Smart Meter Verification scheduler: • ProLink III Basic or Professional: Choose Device Tools → Diagnostics → Meter Verification → Schedule Meter Verification. • ProLink III Professional: Choose Smart Meter Verification Overview → Tools → Schedule Smart Meter Verification. 2. To schedule a single test: a) Set Specify Time Until Next Run to the number of days, hours, and minutes to elapse before the test is run. b) Set Specify Time Between Recurring Runs to 0 days, 0 hours, and 0 minutes. 3. To schedule a recurring execution: a) Set Specify Time Until Next Run to the number of days, hours, and minutes to elapse before the first test is run. b) Set Specify Time Between Recurring Runs to the number of days, hours, and minutes to elapse between runs. 4. To disable scheduled execution, choose Disable Scheduled Execution. Set up Smart Meter Verification automatic execution using a field communicator Field communicator Device Settings → Calibration → Smart Meter Verification → Manual Verification → Start Procedure 1. To schedule a single test: a) Set Hrs Until Next Run to the number of hours to elapse before the test is run. b) Set Recurring Hours to 0. 2. To schedule a recurring execution: a) Set Hrs Until Next Run to the number of hours to elapse before the first test is run. b) Set Recurring Hours to the number of hours to elapse between runs. 3. To disable scheduled execution, select Turn Off Schedule. Set up Smart Meter Verification automatic execution from a Modbus host Use the Modbus host to set up the schedule. Prerequisites To configure a test execution and view a scheduled test execution, the Modbus host must be connected to the transmitter. Once the schedule is loaded into the transmitter, the Modbus host no longer has to be connected to the transmitter. Procedure 1. Choose any of the following options: 144 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 Option Description Specify the hours until test execution for a single execution Write a floating-point value to Register 2993. Specify the hours for a recurring execution • To specify the number of hours until the first test is executed, write a floating-point value to Register 2993. • To specify the number of hours between test executions, write a floating-point value to Register 2995. View the number of hours until the next execution Read Register 2997. Cancel a scheduled execution • Write 0 to Register 2993. • Write 0 to Register 2995. 2. Disconnect as desired. Check for a field reference point Use this procedure to check if a field reference point was created. Prerequisites • Smart Meter Verification Professional • ProLink III Basic or Professional Procedure 1. From ProLink III Basic or Professional, choose one of the following options: • Device Tools → Diagnostics → Meter Verification → Run Test → View Previous Test Results • Smart Meter Verification Overview → Meter Verification → History 2. Select Export Data to CSV File. 3. Save the CSV file to your computer. 4. Locate and open the CSV file. 5. Locate and examine the two columns labeled, Inlet Stiffness and Outlet Stiffness. • If the field reference point has not been established, the numbers in both columns will be exactly 1. • If the field reference point has been established, the numbers located in both columns will be close to 1. The Inlet Stiffness and Outlet Stiffness numbers do not have to match. 13.2 Advanced Phase Measurement software Micro Motion Advanced Phase Measurement software improves long-term flow reporting and measurement performance in processes with intermittent periods of two-phase flow, including liquids with entrained gas or gas with entrained liquid. If Advanced Phase Measurement is combined with the Net Oil or concentration measurement software options, the software can also report liquid concentration, Net Oil, and/or Gas Void Fraction (GVF) during the same two-phase conditions. The following measurement options are available with Advanced Phase Measurement software: • Net Oil • Liquid with Gas Configuration and Use Manual 145 Measurement support May 2024 • Configuration and Use Manual MS-00809-0200-1600 Gas with Liquid Note Each option is licensed separately in the transmitter. Field upgrades are permitted. Table 13-1: Net oil option (MA only) License option Description Availability MA — Manual Advanced Phase Measurement configuration Suitable for a mixture of oil and water under predictable flow conditions. Includes manual drive gain threshold only. This option is the 1600 upgrade for Production Volume Reconciliation (PVR). Do not combine with APM liquid with gas (option PL) — basic remediation for gas is included. License option (ordering code) Description Availability PL — Advanced Phase Measurement Liquid with Gas Suitable for any liquid with entrained gas. Can be combined with license code concentration measurement (CM). License option (ordering code) Description Availability PG — Advanced Phase Measurement Gas with Liquid Suitable for any gas that may contain entrained liquids (mist). Cannot be activated with any other license code. Table 13-2: Liquid with gas Table 13-3: Gas with liquid 13.3 Zero the meter Display Menu → Service Tools → Verification & Calibration → Meter Zero → Zero Calibration ProLink III Device Tools → Calibration → Smart Zero Verification and Calibration → Calibrate Zero Field communicator Device Settings → Calibration → Zero Calibration → Perform Zero Calibration Zeroing the meter establishes a baseline for process measurement by analyzing the sensor's output when there is no flow through the sensor tubes. Important In most cases, the factory zero is more accurate than the field zero. Do not zero the meter unless one of the following is true: • The zero is required by site procedures. • The stored zero value fails the zero verification procedure. Do not verify the zero or zero the meter if a high-severity alert is active. Correct the problem, then verify the zero or zero the meter. You may verify the zero or zero the meter if a low-severity alert is active. Prerequisites Before performing a field zero, execute the zero verification procedure to see whether or not a field zero can improve measurement accuracy. Important Do not verify the zero or zero the meter if a high-severity alert is active. Correct the problem, then verify the zero or zero the meter. You may verify the zero or zero the meter if a low-severity alert is active. 146 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 Procedure 1. Prepare the meter: a) After applying power, allow the meter to warm up for at least 20 minutes. b) Run the process fluid through the sensor until the sensor temperature reaches the normal process operating temperature. c) Stop flow through the sensor by shutting the downstream valve, and then the upstream valve if available. d) Verify that the sensor is blocked in, that flow has stopped, and that the sensor is completely full of process fluid. e) Observe the drive gain, temperature, and density readings. If they are stable, check the Live Zero or Field Verification Zero value. If the average value is close to 0, you should not need to zero the meter. 2. Modify Zero Time, if desired. Zero Time controls the amount of time the transmitter takes to determine its zero-flow reference point. The default Zero Time is 20 seconds. For most applications, the default Zero Time is appropriate. For gas applications, lowering the Zero Time to five seconds is recommended. 3. Start the zero procedure and wait until it completes. When the calibration is complete: • If the zero procedure was successful, a Calibration Success message and a new zero value are displayed. • If the zero procedure failed, a Calibration Failed message is displayed. Postrequisites Restore normal flow through the sensor by opening the valves. Need help? If the zero fails: • Ensure that there is no flow through the sensor, then retry. • Remove or reduce sources of electromechanical noise, then retry. • Set Zero Time to a lower value (especially when measuring gas flow), then retry. • If the zero continues to fail, contact customer service. • If you want to restore the most recent valid value from transmitter memory: — Using the display: Menu → Service Tools → Verification and Calibration → Meter Zero → Restore Zero → Restore Previous Zero — Using ProLink III: Device Tools → Calibration → Smart Zero Verification and Calibration → Calibrate Zero → Restore Prior Zero — Using a field communicator: Not available • If you want to restore the factory zero: — Using the display: Menu → Service Tools → Verification and Calibration → Meter Zero → Restore Zero → Restore Factory Zero — Using ProLink III: Device Tools → Calibration → Smart Zero Verification and Calibration → Calibrate Zero → Restore Factory Zero — Using a field communicator: Device Settings → Calibration → Zero Calibration → Restore Factory Zero Configuration and Use Manual 147 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 Restriction Restore the factory zero only if your meter was purchased as a unit, it was zeroed at the factory, and you are using the original components. Related information Verify the zero 13.3.1 Terminology used with zero verification and zero calibration Term Definition Zero In general, the offset required to synchronize the left pickoff and the right pickoff under conditions of zero flow. Unit = microseconds. Factory zero The zero value obtained at the factory, under laboratory conditions. Field zero The zero value obtained by performing a zero calibration outside the factory. Prior zero The zero value stored in the transmitter at the time a field zero calibration is begun. May be the factory zero or a previous field zero. Manual zero The zero value stored in the transmitter, typically obtained from a zero calibration procedure. It may also be configured manually. Also called “mechanical zero” or “stored zero”. Live zero The real-time bidirectional mass flow rate with no flow damping or mass flow cutoff applied. An adaptive damping value is applied only when the mass flow rate changes dramatically over a very short interval. Unit = configured mass flow measurement unit. Zero stability A laboratory-derived value used to calculate the expected accuracy for a sensor. Under laboratory conditions at zero flow, the average flow rate is expected to fall within the range defined by the zero stability value (0 ± zero stability). Each sensor size and model has a unique zero stability value. Zero calibration The procedure used to determine the zero value. Zero time The time period over which the zero calibration procedure is performed. Unit = seconds. Field verification zero A 3-minute running average of the Live Zero value, calculated by the transmitter. Unit = configured mass flow measurement unit. Zero verification A procedure used to evaluate the stored zero and determine whether or not a field zero can improve measurement accuracy. 13.4 Set up pressure compensation Pressure compensation adjusts process measurement to compensate for the pressure effect on the sensor. The pressure effect is the change in the sensor’s sensitivity to flow and density caused by the difference between the calibration pressure and the process pressure. Tip Not all sensors or applications require pressure compensation. The pressure effect for a specific sensor model can be found in the product data sheet located at Emerson.com. If you are uncertain about implementing pressure compensation, contact customer service. Prerequisites You will need the flow factor, density factor, and calibration pressure values for your sensor. • For the flow factor and density factor, see the product data sheet for your sensor. • For the calibration pressure, see the calibration sheet for your sensor. If the data is unavailable, use 20 psi (1.38 bar). 148 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 You must be able to supply pressure data to the transmitter. 13.4.1 Set up pressure compensation using the display Procedure 1. Choose Menu → Configuration → Process Measurement → Pressure. 2. Set Units to the pressure unit used by the external pressure device. 3. Enter Flow Factor for your sensor. The flow factor is the percent change in the flow rate per psi. When entering the value, reverse the sign. Example If the flow factor is −0.0002 % per psi, enter +0.0002 % per PSI. 4. Enter Density Factor for your sensor. The density factor is the change in fluid density, in g/cm3/psi. When entering the value, reverse the sign. Example If the density factor is −0.000006 g/cm3/psi, enter +0.000006 g/cm3/PSI. 5. Set Calibration Pressure to the pressure at which your sensor was calibrated. The calibration pressure is the pressure at which your sensor was calibrated, and defines the pressure at which there is no pressure effect. If the data is unavailable, enter 20 PSI. Option Description Polling The meter polls an external device for pressure data. Setup a. Set Pressure Source to Poll for External Value. b. Set Polling Slot to an available slot. c. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other Primary HART masters will be on the network. A field communicator is not a HART master. Poll as Secondary No other Secondary HART masters will be on the network. A field communicator is not a HART master. d. Set External Device Tag to the HART tag of the temperature device. Digital communications A host writes pressure data to the meter at appropriate intervals. a. Set Pressure Source to Fixed Value or Digital Communications. b. Perform the necessary host programming and communications setup to write pressure data to the meter at appropriate intervals. Postrequisites The current pressure value is displayed in the External Pressure field. Verify that the value is correct. Configuration and Use Manual 149 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 If you are using external temperature data, verify the external temperature value displayed in the Inputs group on the ProLink III main window. Choose Service Tools → Variables → External Variables and verify the value for External Pressure. Choose Service Tools → Variables → Process → External Pressure and verify the value. Choose Service Tools → Variables → External Variables and verify the value for External Temperature. Choose Service Tools → Variables → Process → External Temperature and verify the value for External Temperature. Choose Menu → Service Tools → Service Data → View Process Variables and verify the value for External Temperature. Choose Menu → Service Tools → Service Data → View Process Variables and verify the values for External Temperature and External Pressure. Choose Service Tools → Variables → External Variables and verify the values for External Temperature and External Pressure. Choose Service Tools → Variables → Process and verify the values for External Temperature and External Pressure. Need help? If the value is not correct: • Ensure that the external device and the meter are using the same measurement unit. • For polling: — Verify the wiring between the meter and the external device. — Verify the HART tag of the external device. 13.4.2 Set up pressure compensation using ProLink III Procedure 1. Choose Device Tools → Configuration → Process Measurement → Pressure Compensation. 2. Set Pressure Compensation Status to Enabled. 3. Set Pressure Unit to the unit used by the external pressure device. 4. Enter the Density Factor and Flow Factor for your sensor. a) Set Process Fluid to Liquid Volume or Gas Standard Volume, as appropriate. b) Compare the values shown in Recommended Density Factor and Recommended Flow Factor to the values from the product data sheet. c) To use the recommended values, click Accept Recommended Values. d) To use different factors, enter your values in the Density Factor and Flow Factor fields. The density factor is the change in fluid density, in g/cm3/psi. When entering the value, reverse the sign. Example If the density factor is −0.000006 g/cm3/psi, enter +0.000006 g/cm3/PSI. The flow factor is the percent change in the flow rate per psi. When entering the value, reverse the sign. 150 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 Example If the flow factor is −0.0002 % per psi, enter +0.0002 % per PSI. 5. Set Flow Calibration Pressure to the pressure at which your sensor was calibrated. The calibration pressure is the pressure at which your sensor was calibrated, and defines the pressure at which there is no pressure effect. If the data is unavailable, enter 20 PSI. Option Description Polling The meter polls an external device for pressure data. Setup a. Set Pressure Source to Poll for External Value. b. Set Polling Slot to an available slot. c. Set Polling Control to Poll as Primary or Poll as Secondary. Option Description Poll as Primary No other Primary HART masters will be on the network. A field communicator is not a HART master. Poll as Secondary No other Secondary HART masters will be on the network. A field communicator is not a HART master. d. Set External Device Tag to the HART tag of the temperature device. Digital communications A host writes pressure data to the meter at appropriate intervals. a. Set Pressure Source to Fixed Value or Digital Communications. b. Perform the necessary host programming and communications setup to write pressure data to the meter at appropriate intervals. Postrequisites The current pressure value is displayed in the External Pressure field. Verify that the value is correct. Need help? If the value is not correct: • Ensure that the external device and the meter are using the same measurement unit. • For polling: — Verify the wiring between the meter and the external device. — Verify the HART tag of the external device. 13.4.3 Configure pressure compensation using a field communicator Field communicator Device Settings → Process Configuration → Optional Setup → External Pressure/Temperature → Pressure Procedure 1. Set Pressure Unit to the unit used by the external pressure device. 2. Enable Pressure Compensation. Configuration and Use Manual 151 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 3. Set Flow Calibration Pressure to the pressure at which your sensor was calibrated. The calibration pressure is the pressure at which your sensor was calibrated, and defines the pressure at which there is no pressure effect. If the data is unavailable, enter 20 PSI. 4. Enter Flow Press Factor for your sensor. The flow factor is the percent change in the flow rate per psi. When entering the value, reverse the sign. Example If the flow factor is −0.0002 % per PSI, enter +0.0002 % per PSI. 5. Enter Density Pressure Factor for your sensor. The density factor is the change in fluid density, in g/cm3/PSI. When entering the value, reverse the sign. Example If the density factor is −0.000006 g/cm3/PSI, enter +0.000006 g/cm3/PSI. 6. Choose the method to be used to supply pressure data, and perform the required setup. Method Description Digital communications A host writes pressure data to the meter at appropriate intervals. Setup a. Using a field communicator, choose Configure → Manual Setup → Measurements → Optional Setup → External Pressure/Temperature → Pressure. b. Set Pressure Compensation to Enable. c. Perform the necessary host programming and communications setup to write pressure data to the transmitter at appropriate intervals. 13.5 Validate the meter Display Menu → Configuration → Process Measurement → Flow Variables → Mass Flow Settings → Meter Factor Menu → Configuration → Process Measurement → Flow Variables → Volume Flow Settings → Meter Factor Menu → Configuration → Process Measurement → Density → Meter Factor ProLink III Device Tools → Configuration → Process Measurement → Flow → Mass Flow Rate Meter Factor Device Tools → Configuration → Process Measurement → Flow → Volume Flow Rate Meter Factor Device Tools → Configuration → Process Measurement → Density → Density Meter Factor Field communicator Device Settings → Process Configuration → Mass Flow → Mass Factor Device Settings → Process Configuration → Volume Flow → Volume Factor Device Settings → Process Configuration → Density → Density Factor Meter validation compares flow meter measurements reported by the transmitter to an external measurement standard. If the transmitter value for mass flow, volume flow, or density measurement is significantly different from the external measurement standard, you may want to adjust the corresponding meter factor. The flow meter’s actual measurement is multiplied by the meter factor, and the resulting value is reported and used in further processing. Changing a meter factor is very uncommon. Usually, it's done by official, legal proving companies. And the meter factor is typically changed in the PLC, not at the meter. 152 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 Prerequisites Identify the meter factor(s) that you will calculate and set. You may set any combination of the three meter factors: mass flow, volume flow, and density. Note that all three meter factors are independent: • The meter factor for mass flow affects only the value reported for mass flow. • The meter factor for density affects only the value reported for density. • The meter factor for volume flow affects only the value reported for volume flow or gas standard volume flow. Important To adjust volume flow, you must set the meter factor for volume flow. Setting a meter factor for mass flow and a meter factor for density will not produce the desired result. The volume flow calculations are based on original mass flow and density values, before the corresponding meter factors have been applied. If you plan to calculate the meter factor for volume flow, be aware that validating volume in the field may be expensive, and the procedure may be hazardous for some process fluids. Obtain a reference device (external measurement device) for the appropriate process variable. Important For good results, the reference device must be highly accurate. Procedure 1. Determine the meter factor as follows: a) Use the flow meter to take a sample measurement. b) Measure the same sample using the reference device. c) Calculate the meter factor using the following formula: NewMeterFactor = ConfiguredMeterFactor × ReferenceMeasurement FlowmeterMeasurement 2. Ensure that the calculated meter factor does not fall outside 0.98 and 1.02. If the meter factor is outside these limits, contact customer service. 3. Configure the meter factor in the transmitter. Calculating the meter factor for mass flow The flow meter is installed and validated for the first time. The mass flow measurement from the transmitter is 250.27 lb. The mass flow measurement from the reference device is 250 lb. The mass flow meter factor is calculated as follows: MeterFlowMassFlow = 1 x The first meter factor for mass flow is 0.9989. 250 = 0.9989 250.27 One year later, the flow meter is validated again. The mass flow measurement from the transmitter is 250.07 lb. The mass flow measurement from the reference device is 250.25 lb. The new mass flow meter factor is calculated as follows: MeterFlowMassFlow = 0.9989 x 250.25 = 0.9996 250.07 The new meter factor for mass flow is 0.9996. Configuration and Use Manual 153 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 13.6 Perform a (standard) D1 and D2 density calibration Density calibration establishes the relationship between the density of the calibration fluids and the signal produced at the sensor. Density calibration includes the calibration of the D1 (low density, usually air) and D2 (high density, usually water) calibration points. Important Micro Motion flow meters are calibrated at the factory, and normally do not need to be calibrated in the field. Calibrate the flow meter only if you must do so to meet regulatory requirements. Contact customer support before calibrating the flow meter. Tip Use meter validation and meter factors, rather than calibration, to prove the meter against a regulatory standard or to correct measurement error. Prerequisites • During density calibration, the sensor must be completely filled with the calibration fluid, and flow through the sensor must be at the lowest rate allowed by your application. This is usually accomplished by closing the shutoff valve downstream from the sensor, then filling the sensor with the appropriate fluid. • D1 and D2 density calibration require a D1 (low-density) fluid and a D2 (high-density) fluid. You may use air and water. • If LD Optimization is enabled on your meter, disable it. To do this using a field communicator, choose Device Tools → Configuration → Informational Parameters → Sensor → LD Optimization and select Disable. LD Optimization is used only with large sensors in hydrocarbon applications. If you are not using a field communicator, contact Emerson before continuing. • The calibrations must be performed without interruption, in the order shown. Ensure that you are prepared to complete the process without interruption. • Before performing the calibration, record your current calibration parameters. You can do this by saving the current configuration to a file on the PC. If the calibration fails, restore the known values. 13.6.1 Perform a D1 and D2 density calibration using the display Procedure 1. Read the Prerequisites in Perform a (standard) D1 and D2 density calibration if you have not already done so. 2. Close the shutoff valve downstream from the sensor. 3. Fill the sensor with the D1 fluid and allow the sensor to achieve thermal equilibrium. 4. Choose Menu → Service Tools → Verification and Calibration → Density Calibration. 5. Perform the D1 calibration. a) Choose D1 (Air). b) Enter the density of your D1 fluid. c) Choose Start Calibration. d) Wait for the calibration to complete. This should take approximately 10 seconds. e) Choose Finished. 6. Fill the sensor with the D2 fluid and allow the sensor to achieve thermal equilibrium. 154 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 7. Perform the D2 calibration. a) Choose D2 (Water). b) Enter the density of your D2 fluid. c) Choose Start Calibration. d) Wait for the calibration to complete. This will take approximately 10 seconds. e) Choose Finished. 8. Open the shutoff valve. 13.6.2 Perform a D1 and D2 density calibration using ProLink III Procedure 1. Read the Prerequisites in Perform a (standard) D1 and D2 density calibration if you have not already done so. 2. See the Figure 13-1. Figure 13-1: D1 and D2 Calibration Work Flow Using ProLink III D1 Calibration Close shutoff valve downstream from sensor Fill sensor with D1 fluid D2 Calibration Fill sensor with D2 fluid ProLink Menu > ProLink Menu > Calibration > Calibration > Density Cal - Point 1 Density Cal - Point 2 Enter density of D1 fluid Enter density of D2 fluid Do Cal Do Cal Calibration in Progress light turns red Calibration in Progress light turns red Calibration in Progress light turns green Calibration in Progress light turns green Close Close Done 13.6.3 Perform a D1 and D2 density calibration using a field communicator Procedure 1. Read the Prerequisites in Perform a (standard) D1 and D2 density calibration if you have not already done so. Configuration and Use Manual 155 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 2. See Figure 13-2. Figure 13-2: D1 and D2 Calibration Work Flow with a Field Communicator Postrequisites If you disabled LD Optimization before the calibration procedure, re-enable it. 13.7 Adjust concentration measurement with Trim Offset Trim Offset adjusts the meter's concentration measurement to match a reference value. Tip You can adjust concentration measurement by applying the trim offset only, or by applying both the trim offset and the trim slope. For most applications, the trim offset is sufficient. 156 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Measurement support May 2024 Prerequisites Ensure that the active matrix is the one that you want to trim. You can set the offset separately for each matrix on your transmitter. You must be able to take a sample of your process fluid and obtain a laboratory concentration value at line density and line temperature. Procedure 1. Take a concentration reading from the meter, and record line density and line temperature. 2. Take a sample of the process fluid and obtain a laboratory value for concentration at line density and line temperature, in the units used by the meter. 3. Subtract the meter value from the laboratory value. 4. Enter the result as the trim offset. • Using ProLink III: Choose Device Tools → Configuration → Process Measurement → Concentration Measurement, set Matrix Being Configured to your matrix, and enter Trim Offset. • Using a field communicator: Choose Configure → Manual Setup → Measurements → Optional Setup → Conc Measurement → Configure Matrix and set Matrix Being Configured to your matrix. Then choose Service Tools → Maintenance → Calibration → Trim CM Process Variables and enter Concentration Offset. 5. Take another concentration reading from the meter, and compare it to the laboratory value. • If the two values are acceptably close, the trim is complete. • If the two values are not acceptably close; i.e. not within the density specification of the sensor, repeat this procedure. Calculating the trim offset Laboratory value 64.21 °Brix Meter value 64.93 °Brix Concentration offset: −0.72 64.21 − 64.93 = −0.72 13.8 Adjust concentration measurement with Trim Slope and Trim Offset Trim Slope and Trim Offset adjust the meter's concentration measurement to match a reference value. Tip You can adjust concentration measurement by applying the trim offset only, or by applying both the trim offset and the trim slope. For most applications, the trim offset is sufficient. Prerequisites Ensure that the active matrix is the one that you want to trim. You can set the offset and slope separately for each matrix on your transmitter. You must be able to take measurements of your process fluid at two different concentrations. You must be able to take a sample of your process fluid at each of these concentrations. For each sample, you must be able to obtain a laboratory concentration value at line density and line temperature. Configuration and Use Manual 157 Measurement support May 2024 Configuration and Use Manual MS-00809-0200-1600 Procedure 1. Collect data for Comparison 1. a) Take a concentration reading from the meter and record line density and line temperature. b) Take a sample of the process fluid at the current concentration. c) Obtain a laboratory value for concentration at line density and line temperature, in the units used by the meter. 2. Collect data for Comparison 2. a) Change the concentration of your process fluid. b) Take a concentration reading from the meter and record line density and line temperature. c) Take a sample of the process fluid at the current concentration. d) Obtain a laboratory value for concentration at line density and line temperature, in the units used by the meter. 3. Populate the following equation with values from each comparison. 4. Solve for A (slope). ConcentrationLab = A × ConcentrationMeter + B 5. Solve for B (offset), using the calculated slope and one set of values. 6. Enter the results as the trim slope and the trim offset. • Using ProLink III: Choose Device Tools → Configuration → Process Measurement → Concentration Measurement, set Matrix Being Configured to your matrix, and enter Trim Slope and Trim Offset. • Using a field communicator: Choose Device Settings → Process Configuration → Optional Setup → Concentration Measurement → Configure Matrix and set Matrix Being Configured to your matrix. Then choose Device Settings → Process Configuration → Optional Setup → Concentration Measurement → Trim CM Process Variables and enter Concentration Slope and Concentration Offset. 7. Take another concentration reading from the meter, and compare it to the laboratory value. • If the two values are acceptably close, the trim is complete. • If the two values are not acceptably close, repeat this procedure. Calculating the trim slope and the trim offset Comparison 1 Comparison 2 Laboratory value 50.00% Meter value 49.98% Laboratory value 16.00% Meter value 15.99% Populate the equations: Solve for A: 50 = A × 49.98 + B 16 = A × 15.99 + B 50.00 − 16.00 = 34.00 49.98 − 15.99 = 39.99 34 = A × 33.99 158 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Solve for B: Concentration slope (A): 1.00029 Concentration offset (B): 0.00551 Configuration and Use Manual Measurement support May 2024 A = 1.00029 50.00 = 1.00029 × 49.98 + B 50.00 = 49.99449 + B B = 0.00551 159 Measurement support May 2024 160 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Maintenance May 2024 14 Maintenance 14.1 Install a new transmitter license Display Menu → Service Tools → License Manager ProLink III Device Tools → Configuration → Feature License Field communicator Not available Whenever you purchase additional features or request a trial license, you must install a new transmitter license. The new license makes the new features available on your transmitter. For concentration measurement and API Referral, you may still need to enable the application. Prerequisites • You must have a license file provided by Micro Motion: — perm.lic: Permanent license file — temp.lic: Temporary license file • A USB-C drive Procedure • To install a license using the display: a) Choose Menu → Service Tools → License Manager. Choose either Enter Permanent License or Enter Trial License. b) Use the arrow keys to enter the license key. • To install a license using ProLink III: a) Open the license file. b) Choose Device Tools → Configuration → Feature License. c) Copy the license from the file to the appropriate License Key field. The features supported by the new license are displayed. If you installed a temporary license, the transmitter will revert to its original feature set when the license period has expired. To purchase a feature for permanent use, contact customer support. Postrequisites If you installed a permanent license, update the options model code to match the new license. The options model code represents the installed features. No power cycling or disconnecting and reconnecting to the transmitter is necessary. Configuration and Use Manual 161 Maintenance May 2024 Configuration and Use Manual MS-00809-0200-1600 14.2 Upgrade the transmitter firmware You can upgrade the transmitter firmware to stay current with development and to take advantage of any new features. 14.2.1 Using a USB drive with the display You must have the firmware upgrade files provided by Micro Motion. Prerequisites The service port must be enabled. It is enabled by default. However, if you need to enable it, choose Menu → Configuration → Security and set Service Port to On. Any USB-C device used will need to be formatted using the FAT/FAT 32 file system. Procedure 1. Copy the folder containing the firmware upgrade files to a USB drive. 2. Open the wiring compartment and insert the USB drive into the service port. WARNING If the transmitter is in a hazardous area, do not remove the housing cover while the transmitter is powered up. Failure to follow these instructions can cause an explosion, resulting in serious injury or death. 3. Follow the prompts once the transmitter recognizes the USB drive. 4. Select USB Drive → Transmitter. 5. Select Update Device Software. 6. Select the firmware upgrade folder and follow the prompts. Note If required, the transmitter upgrade procedure automatically includes an upgrade to the core processor software. If you chose to reboot the transmitter at a later date, you can reboot it from the menu, or you can power-cycle it. 7. Verify the transmitter configuration and all safety parameters. 8. Enable write-protection. 14.2.2 Using the USB-C service port and ProLink III You can upgrade the transmitter firmware to stay current with development and to take advantage of any new features. WARNING If the transmitter is in a hazardous area, do not remove the housing cover while the transmitter is powered up. Failure to follow these instructions can cause an explosion, resulting in serious injury or death. Prerequisites You must have the firmware upgrade files provided by Emerson. Procedure 1. In ProLink III, choose Device Tools → Transmitter Software Update. 2. Navigate to the folder containing the firmware upgrade files. 162 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Maintenance May 2024 3. Select Update. Files will be copied to the transmitter. However, the transmitter will not be updated until it is rebooted. ProLink will give you the option to reboot once the files are copied. If you chose to reboot the transmitter at a later date, you can reboot it from the display, or you can power-cycle it. 4. Verify the transmitter configuration and all safety parameters. 14.3 Reboot the transmitter Display Menu → Service Tools → Reboot Transmitter ProLink III Not available Field communicator Device Settings → Restore/Restart → Device Reset For certain configuration changes to take effect, the transmitter must be rebooted. You must also reboot the transmitter in order to clear certain status alerts. Rebooting the transmitter has the same effect as power-cycling the transmitter. Prerequisites Follow appropriate procedures to select the appropriate time for rebooting the transmitter. The reboot typically takes about 10 seconds. Postrequisites Check the transmitter clock. During the reboot, the transmitter clock is powered by the battery, therefore the transmitter clock and all timestamps should be accurate. If the transmitter clock is not correct, the battery may need replacement. 14.4 Battery replacement The transmitter contains a battery that is used to power the clock when the transmitter is not powered up. Users cannot service or replace the battery. If the battery requires replacement, contact customer support. If the battery is non-functional and the transmitter is powered down, then powered up, the clock will restart from the time of the power-down. All timestamps will be affected. You can correct the issue by resetting the transmitter clock. For a permanent resolution, the 1600 module must be replaced. Configuration and Use Manual 163 Maintenance May 2024 164 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Log files, history files, and service files May 2024 15 Log files, history files, and service files 15.1 Generate history files Display(1) Menu → USB Options → Transmitter → USB Drive → Download Historical Files Menu → USB Options → Transmitter → USB Drive → Download Service Files ProLink III Device Tools → Configuration Transfer → Download Historical Files Field communicator Not available (1) Requires a USB connection. The transmitter automatically saves historical data of several types, including process and diagnostic variables, Smart Meter Verification test results, and totalizer values. To access the historical data, you can generate a log file, then view it on your PC. WARNING If the transmitter is in a hazardous area, do not remove the housing cover while the transmitter is powered up. Failure to follow these instructions can cause an explosion resulting in injury or death. Prerequisites If you want to generate a totalizer log, you must have previously configured the transmitter to record totalizer data. However, there is a totalizer history that is logged automatically. Procedure 1. Select the type of log file that you want to generate. 2. If you selected historian data (process and diagnostic variables): a) Set the date and time for the first entry in the historian log file. b) Set the number of days that the log file will include. c) Select the record type. Option Description 1 Second Raw Data The current values of process and diagnostic variables, recorded at 1-second intervals. 5 Min Average Data The minimum and maximum values of the 1-second raw data over the last 5 minutes, plus the average and the standard deviation, recorded at 5-minute intervals. The system provides an estimated file size or transfer time. The log file is written to the specified location. File names are assigned as follows: • Historian files: The file name is based on the transmitter tag, the starting date of the log contents, and the record type. The record type is shown as F or S: — F = Fast, for 1-second raw data — S = Slow, for 5-minute average data • SMV files: — SmvLast20Data.csv Configuration and Use Manual 165 Log files, history files, and service files May 2024 Configuration and Use Manual MS-00809-0200-1600 — SmvLongTermData.csv • Totalizer history files: TotLog.txt 15.1.1 Historian data and log The 1600 transmitter offers a licensable Data Historian option. If enabled, the transmitter automatically saves information about specific process and diagnostic variables. You can generate a log from this data that tracks totalizers and inventories with 21 days worth of data. The historian log is an ASCII file in .csv format. Contents of the historian log There are two types of historian records: 1-second raw data The current values of process and diagnostic variables, recorded at 1-second intervals. 5-minute average data The minimum and maximum values of the 1-second raw data, plus the average and the standard deviation, calculated and recorded at 5-minute intervals. When you generate the log, you can specify which type of record you want to see. The historian in the transmitter internal memory contains a minimum of 7 days of 1-second raw data and 30 days of 5-minute average data. Each record contains data for the following process and diagnostic variables: • Timestamp — Format: Military time — Time and time zone: Transmitter clock • Mass flow rate (kg/sec) • Volume flow rate (l/sec) or GSV flow rate • Density (g/cm³) • Line temperature (°C) • External temperature (if available) • Pressure (if available) • If concentration measurement is enabled: — Standard volume flow rate — Net mass flow rate — Net volume flow rate — Referred density — Concentration • If API Referral is enabled: — CTPL or CTL — Corrected density — Corrected volume flow rate • Alert status registers (hexadecimal format) • Live zero (kg/sec) • Tube frequency (Hz) • Drive gain (%) 166 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Log files, history files, and service files May 2024 • Left pickoff (filtered) (V) • Right pickoff (filtered (V) • Left pickoff (raw) (V) • Delta T • Case temperature (°C) • Voltage applied to the core processor (V) • Temperature of the core processor board (°C) • Temperature of the transmitter electronics (°C) Historian data and power-cycles Historian data is maintained across transmitter reboots and power-cycles. Historian data and configuration files If you restore the factory configuration or upload a configuration file, existing historian data is not affected. Example: Historian log, 5-minute average data S TAG:SUPPLY UID:22729F1F SW:000000045 800:000000402 MassFlow MassFlow MassFlow MassFlow … DST ON:Mountain GMT-7.0 SM:T075 SN:000000000 kg/s Max kg/s Min kg/s Avg kg/s Std … 8/25/2020 9:58 0.0082359 0 0.00091223 9.76E-05 … 8/25/2020 10:03 0.001018 0.00084441 0.00091756 1.61E-05 … 8/25/2020 10:08 0.00099489 0.00086279 0.00092519 1.44E-05 … 8/25/2020 10:13 0.0010835 0.00080879 0.00093774 2.01E-05 … 8/25/2020 10:18 0.0011767 0.00084206 0.00094224 2.11E-05 … 8/25/2020 10:23 0.0010243 0.00086888 0.00094534 1.85E-05 … 8/25/2020 10:28 0.0010903 0.00084823 0.00094747 1.81E-05 … 8/25/2020 10:33 0.0010319 0.00085327 0.00095123 1.67E-05 … 8/25/2020 10:38 0.0011232 0.00088614 0.00095222 1.59E-05 … 8/25/2020 10:43 0.0010841 0.00081306 0.00095126 1.99E-05 … 8/25/2020 10:48 0.0010999 0.00086106 0.00095333 1.93E-05 … 8/25/2020 10:53 0.0011523 0.00085537 0.00095528 2.01E-05 … … Note The historian log displays only in English and the .csv file saves everything in base engineering units of kg/sec, l/s, deg C, g/cc, bar and m/s. Time is saved in UTC time. Configuration and Use Manual 167 Log files, history files, and service files May 2024 Configuration and Use Manual MS-00809-0200-1600 15.1.2 Smart Meter Verification history and log The transmitter automatically saves test data for all Smart Meter Verification tests. You can generate a log containing data for the 20 most recent tests or for all Smart Meter Verification tests. The log is an ASCII file in .csv format. Contents of Smart Meter Verification log Each record in the Smart Meter Verification log represents a Smart Meter Verification test. Each record contains the following information: • Date and time of test • Data collected during the test • The abort code (15 = test completed normally) • A pass/fail result for the left pickoff (0 = Pass, 1 = Fail) • A pass/fail result for the right pickoff (0 = Pass, 1 = Fail) • The sensor type code • The sensor serial number Smart Meter Verification history and power-cycles If the transmitter is rebooted or power-cycled, Smart Meter Verification history is not affected. Smart Meter Verification history and configuration files If you restore the factory configuration or upload a configuration file, Smart Meter Verification history is not affected. 15.1.3 Totalizer log The totalizer log can track four configurable totals. The period is configurable; you can configure the transmitter to save totalizer and inventory values at a user-specified interval and then generate a totalizer log. The totalizer log is an ASCII file. Contents of totalizer log The totalizer log contains one record for each logged totalizer or inventory value. Each record contains the following information: • Default totalizer or inventory name (user-specified names are not used) • Value and measurement unit • Timestamp — Format: Military time — Time and time zone: Transmitter clock The totalizer log also contains a line item for each totalizer or inventory reset. Note • The historian totalizer log is configurable, but defaults to mass and volume totalizers logged at one hour intervals. • The entire log saves 240 lines before rolling the last lines out, so 5 days of totalizer data are saved by default. Totalizer logs and power cycles If the transmitter is rebooted or power-cycled, the totalizer log is not affected. 168 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Log files, history files, and service files May 2024 Totalizer logs and configuration files If you restore the factory configuration or upload a configuration file, the totalizer log is not affected. Example: Totalizer log ================================================================================ Device UID: 22729F1F Name Device Tag: SUPPLY Value Units Time Zone: GMT-7.00 ================================================================================ Mass Fwd Total 61.74707 grams 9/12/2020 20:00 Mass Fwd Inv 61.74705 grams 9/12/2020 20:00 Mass Fwd Total 61.74707 grams 9/12/2020 21:00 Mass Fwd Inv 61.74705 grams 9/12/2020 21:00 Mass Fwd Total 61.74707 grams 9/12/2020 22:00 Mass Fwd Inv 61.74705 grams 9/12/2020 22:00 Mass Fwd Total 61.74707 grams 9/12/2020 23:00 Mass Fwd Inv 61.74705 grams 9/12/2020 23:00 Mass Fwd Total 61.74707 grams 9/13/2020 0:00 Mass Fwd Inv 61.74705 grams 9/13/2020 0:00 … Note The totalizer history displays only in English. Read contract totals You can read contract totals for the current 24-hour contract period and for the previous 24-hour contract period. Depending on the configuration of the totalizer log, you may be able to read contract totals for earlier periods. The contract totals are derived from existing inventories. However, they are reset automatically at the beginning of each contract period. Therefore, the values shown will probably not match the values shown for the inventories. Important You can reset inventories manually, and you can stop and start inventories manually. However, if you do this, data for the current contract period will not reflect the entire 24-hour period. Data for earlier contract periods is not affected. • The contract totals for the current contract period are stored in the Today's Total [1-4] parameters. • The contract totals for the previous contract period are stored in the Yesterday's Total [1-4] parameters. • The contract totals from earlier contract periods can be read in the totalizer log if configured. Configuration and Use Manual 169 Log files, history files, and service files May 2024 Configuration and Use Manual MS-00809-0200-1600 Configure contract totals into the totalizer log The transmitter can be configured to store contract totals to the totalizer log. This allows you to access totals from earlier contract periods. Otherwise, the transmitter maintains data for only the current contract period (today) and the immediately preceding contract period (yesterday). Procedure 1. Navigate to the Totalizer Log. Option Description Display Menu → Configuration → Totalizer Log ProLink III Device Tools → Configuration → Totalizer Log Field communicator Not available 2. Set Log Total 1, Log Total 2, Log Total 3, and/or Log Total 4 to the desired contract total. You can configure the totalizer history log to include both Advanced Phase Measurement and standard totals. 15.2 Generate service files The transmitter automatically saves several types of service data that is useful in troubleshooting, device maintenance, and administration. You can view the data by using ProLink III to generate a service file and then clicking on the ProcessViz button to view the data, or by using your PC to open the file. Prerequisites If you use the first option from step 1, the service port must be enabled. It is enabled by default. However, if you need to enable it, choose Menu → Configuration → Security and set Service Port to On. Note It may take as long as 10 minutes to generate a service file. Procedure 1. WARNING If the transmitter is in a hazardous area, do not remove the housing cover while the transmitter is powered up. Failure to follow these instructions can cause an explosion, resulting in serious injury or death. Perform one of the following tasks: Option Description Service port Use the USB-C cable to connect to the service port. 2. From ProLink III , select Device Tools → File Transfer → Download Service Files. 3. Click on Download all files. This could take 10 to 15 minutes. 4. If you know which files you would like to download, click Show Additional Options and select the service files that you want to generate. 170 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Log files, history files, and service files May 2024 Service file Description File name Configuration Audit Log All changes to configuration, including changes made by procedures such as zero calibration or density calibration. Stores the last 1000 configuration changes. ConfgAuditLog.txt Alert History All occurrences of alerts and conditions, independent of alert severity. Stores the last 1000 configuration changes. AlertLog.txt Historian: 30 Days 5-minute average values for selected process and diagnostic variables for the last 30 days. Concatenated from transmitter tag and date Historian: 1 Day Values of selected process and diagnostic variables for the last 24 hours, recorded at 1-second intervals. Concatenated from transmitter tag and date SMV: 20 Runs Test data from the 20 most recent SMV tests. SmvLast20Data.csv Service Snapshot An ASCII file containing a snapshot of the transmitter internal database. This file is used by customer service. service.dump Factory Config File The configuration file created for this transmitter at the factory. FactoryConfig.cfg Assert Log A troubleshooting file used by customer service. AssertLog.txt Security Log A record of events that might indicate tampering. SecurityLog.txt 5. Save and specify the folder on the computer where the log file will be saved. 15.2.1 Alert history and log The transmitter automatically saves information about all alert occurrences to its internal memory. The alert history log is an ASCII file. Contents of alert history The alert history in the transmitter internal memory contains the 1000 most recent alert records. Each alert record contains the following information: • Name of alert or condition • Category: — F = Failure — FC = Function Check — M = Maintenance Required — OOS = Out of Specification — I = Ignore • Action: — Active = Transition from inactive to active — Inactive = Transition from active to inactive — Toggling = More than 2 transitions in the last 60 seconds • Timestamp — Format: Military time — Time and time zone: Transmitter clock Configuration and Use Manual 171 Log files, history files, and service files May 2024 Configuration and Use Manual MS-00809-0200-1600 — Not displayed if Action = Toggling Alert history and power-cycles If the transmitter is rebooted or power-cycled, the 20 most recent records in alert history are retained in the transmitter internal memory. All earlier records are cleared from internal memory. Alert history and configuration files If you restore the factory configuration or upload a configuration file, alert history is not affected. 15.2.2 Configuration audit history and log The transmitter automatically saves information about all configuration events to its internal memory. The configuration audit log is an ASCII file. Contents of configuration audit log The configuration audit log contains a record for every change to transmitter configuration, including changes resulting from zero calibration, density calibration, etc. Each record contains: • Modbus location in transmitter memory — Cnnn = Coil — Rnnn = Register — Rnnn xxx = Array, indexed by register xxx • Name of Modbus location • Original value • New value • Measurement unit, if applicable • Timestamp — Format: Military time — Time and time zone: Transmitter clock • Host or protocol from which the change was made Configuration audit history and power-cycles If the transmitter is power-cycled or rebooted, the event is logged in the configuration audit history. Earlier records are not affected. Configuration audit history and configuration files If you restore the factory configuration or upload a configuration file, the event is logged in the configuration audit history. Earlier records are not affected. Example: Configuration audit log ==================================================================================== Device UID: 22729F1F Device Tag: SUPPLY Addr Name Old Value New Value Unit Time Zone: GMT-7:00 Host ==================================================================================== C167 SYS_CfgFile_Re 0 1 09/SEP/2019 11:35:11 Display C167 SYS_CfgFile_Re 0 0 09/SEP/2019 11:35:12 Other 172 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Log files, history files, and service files May 2024 1167 IO_ChannelB_As 1 4 09/SEP/2019 11:35:12 Other 351 SNS_API2540Tab 81 100 09/SEP/2019 11:35:12 Other 40 SNS_DensityUni 91 92 09/SEP/2019 11:35:12 Other 44 SNS_PressureUn 6 12 09/SEP/2019 11:35:12 Other 14 FO_1_Source 0 5 09/SEP/2019 11:35:12 Other 1180 MAI_Source 251 55 09/SEP/2019 11:35:12 Other 275 MAI_mA20Var 0 250.0 09/SEP/2019 11:35:12 Other 68 SYS_Tag FT-0000 SUPPLY 09/SEP/2019 11:35:12 Other 159 SNS_K1 1606.9 1606.4 09/SEP/2019 11:35:12 Other 161 SNS_K2 1606.9 7354 09/SEP/2019 11:35:12 Other 163 SNS_DensityTem 5.66 4.44 09/SEP/2019 11:35:12 Other °C … Note The configuration audit log displays only in English. 15.2.3 Assert history and log The transmitter automatically saves information about all asserts. You can generate an assert log for use by customer service. The assert log is an ASCII file. Contents of assert log The assert history contains the 1000 most recent asserts. An assert is an unusual event in the transmitter firmware that may indicate an error or malfunction. A list of asserts can be useful for troubleshooting by customer service. The assert log is not designed for customer use. Assert history and power-cycles Assert history is not affected by reboots or power-cycles. Assert history and configuration files If you restore the factory configuration or upload a configuration file, assert history is not affected. 15.2.4 Security log Counters are maintained to track the number of illegal configuration change requests, firmware upgrade failures, and failures to enter the display password. The security log is an ASCII file. Contents of security log The security log contains a summary of security events that have occurred since the last transmitter reboot. The following items are included: • Device information • Timestamp — Format: Military time — Time and time zone: Transmitter clock • Number of password entry failures • Number of transmitter firmware upgrade failures Configuration and Use Manual 173 Log files, history files, and service files May 2024 • Configuration and Use Manual MS-00809-0200-1600 Number of database write failures Security log and power-cycles If the transmitter is rebooted or power-cycled, the security log is not affected. 174 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Log files, history files, and service files May 2024 Security log and configuration files If you attempt to restore the factory configuration or upload a configuration file when write-protection is enabled, the Database Write Failures counter is increased. Example: Security log file TAG:SUPPLY UID:22729F1F SW:0045 Device:Config I/O GMT-7.0 DST:DST Zone:(UTC-7:00) Denver Addr Name DATE:23/SEP/2019 14:42:58 Value --------------------------------------------------------------------------------------------------------------------------------------------------5851 Password Failures 0 5852 SW Upgrade Failures 0 5853 Database Write Failures 25636 Note The security log displays only in English. Configuration and Use Manual 175 Log files, history files, and service files May 2024 176 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16 Troubleshooting 16.1 Status LED and device status The status LED (MOD STATUS) on the transmitter display provides a quick indication of device status by changing color and flashing. If the transmitter was ordered without a display, the LEDs on the outputs board inside the transmitter provide the same information. Table 16-1: Status LED and device status Status LED condition Device status Solid green No alerts are active. Solid yellow One or more alerts are active with Alert Severity = Out of Specification, Maintenance Required, or Function Check. Solid red One or more alerts are active with Alert Severity = Failure. Flashing yellow (1 Hz) Auto zero or SMV test in progress Flashing green An auto zero is being performed. Status LED off Transmitter is not receiving power. Display is not seated or not functioning properly. 16.2 API Referral troubleshooting 16.2.1 Extrapolation alert is active Cause Line pressure, line temperature, or line density is outside the range of the configured API table. Recommended actions 1. Check your process conditions against the values reported by the device. 2. Verify the configuration of the API Referral application and related parameters. 16.2.2 Inaccurate referred density reading Cause • Inaccurate density measurement • Inaccurate temperature measurement • Incorrect reference conditions • Incorrect API table selection Recommended actions 1. Verify the line density value. 2. Verify the line temperature value. 3. Ensure that the application is configured to use the appropriate temperature source. 4. Ensure that the pressure source is configured correctly, that the external pressure device is operating correctly, and that both devices are using the same measurement units. Configuration and Use Manual 177 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 5. Ensure that reference temperature and reference pressure, if applicable, are configured correctly. 6. Ensure that the selected API table is appropriate for the process fluid. 16.3 Batch troubleshooting 16.3.1 Batch will not start Cause • Previous batch not ended • Valve is closed but the transmitter is detecting flow • No discrete output configured for batch control • Active alarm(s) present • Totals were not reset Recommended actions 1. End the batch. 2. Check for two-phase flow. 3. Verify the zero. 4. Verify the cutoffs. 5. Set up a channel to operate as a discrete output, and configure it for batch control. 16.3.2 Valve operation is backwards Cause • Discrete Output wiring is incorrect • Discrete Output polarity is reversed Recommended actions 1. Verify the wiring between the Discrete Output and the valve. The ON signal must open the valve. Perform a loop test. 2. Change the setting of Discrete Output Polarity. 16.3.3 Valve does not operate Cause • Discrete Output wiring is incorrect. • Discrete Output channel is set up for internal power. The discrete output is capable of sourcing only 7 mA. It may be necessary to switch to external power with an external power source and current limiting resistor. Recommended actions 1. Verify the wiring between the Discrete Output and the valve. The ON signal must open the valve. Perform a loop test. 2. Ensure that the channel is wired and configured for external power. 3. Ensure that the valve and channel are powered. 178 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.3.4 Batch totals are inaccurate Cause • Batch target is incorrect • AOC is inaccurate • Flow measurement needs adjustment Recommended actions 1. Verify that the correct batch preset is active. 2. Verify that the batch target is set correctly. 3. If you have recently changed the batch target, run a few batches and wait for the AOC value to adjust. 4. Repeat AOC calibration. 5. Adjust the fixed AOC value. 6. Compare the batch total to a scale reading. 16.3.5 Batch repeat not satisfactory Cause • AOC is inaccurate • Inconsistent or leaking valve • Process is unstable Recommended actions 1. Inspect the valve and replace if necessary. 2. Repeat AOC calibration. 3. Ensure that line pressure is stable. 4. Ensure that tank level is approximately constant. 5. Ensure that the pump is not causing unstable flow. 6. If the batch duration is <10 seconds, call Customer Support. 16.4 Concentration measurement troubleshooting 16.4.1 Significantly incorrect CM after loading matrix Cause The wrong temperature or density unit was configured when the matrix was loaded. Recommended actions Set the temperature and density units to the units used when the matrix was built, then reload the matrix. For custom matrices, contact customer support. 16.4.2 Inaccurate CM reading Cause • Inaccurate density measurement Configuration and Use Manual 179 Troubleshooting May 2024 • Inaccurate temperature measurement • Incorrect reference conditions • Incorrect matrix data • Inappropriate trim values Configuration and Use Manual MS-00809-0200-1600 Recommended actions 1. Verify the line density value. 2. Verify the line temperature value. 3. Ensure that the application is configured to use the appropriate temperature source. 4. Ensure that reference temperature is configured correctly. 5. Ensure that the appropriate matrix is active. 6. Ensure that the matrix is configured correctly. 7. Adjust the extrapolation limits for the active matrix. 8. Adjust measurement with a concentration offset trim. 16.5 Alert when connecting a core processor to a remote 1600 Transmitter When connecting a core processor to a 1600 transmitter, you will see the following alert from the transmitter display: Alert New Core Detected Cause A new core processor was detected. Recommended actions 1. Select one of the following options when prompted by the screen. 180 Option Description Action Core Only Replacement The new core processor is replacing an old core processor and the sensor is not getting replaced. The core processor is brand new without a baseline and has default factory values, such as K1 = 1000 and K2 = 5000. Restore configuration and verify sensor parameters. Pre-Calibrated Core Replacement The new core processor is precalibrated and matched with the sensor. You are replacing a core processor that has already been paired with a sensor that has already been characterized. Verify the sensor parameters and save the configuration. Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 Option Description Action Not Pre-Calibrated Core Replacement The core processor and sensor are being replaced, but the core processor has not been precalibrated or matched with the sensor. The sensor and core processor are being replaced but the new core processor has not been paired (characterized) with the new sensor. Enter the sensor parameters and save the configuration. I Don't Know You do not know if the new core processor has been pre-calibrated and matched with the sensor. Verify the sensor parameters and save the configuration if there was a change. 2. Select Continue. 3. Per the screen message, contact Emerson if you have any questions before you select the Finished button. These screens will not display again until another new core processor has been detected. 16.6 Density measurement troubleshooting 16.6.1 Erratic density reading Cause • Normal process noise • Two-phase flow • Line pressure too low • The flow rate is too high for the installation • Pipe diameter too small • Contaminants or suspended solids in the process gas • Contaminants or suspended solids in the process fluid • Vibration in the pipeline • Erosion or corrosion Recommended actions 1. Check for alerts. 2. Check your process conditions against the values reported by the device. 3. Decrease the flow rate. 4. Check for two-phase flow. 5. Ensure that line pressure or sample pressure meets installation requirements. 6. Increase back pressure to minimize bubble formation. 7. Minimize vibration in the pipeline. 8. Increase the pipe diameter. 9. Install a flow control method (bypass, flow chamber, expander, etc.). Configuration and Use Manual 181 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 10. Perform Smart Meter Verification. 16.6.2 Inaccurate density reading Cause • Problem with process fluid • Incorrect density calibration factors • Wiring problem • Two-phase flow • Plugged or coated sensor tube • Incorrect sensor orientation • RTD failure • Physical characteristics of sensor have changed Recommended actions 1. Check the wiring between the sensor and the transmitter. 2. Check the grounding of all components. 3. Check your process conditions against the values reported by the device. 4. Ensure that all of the calibration parameters have been entered correctly. See the sensor tag or the calibration sheet for your meter. 5. Check for two-phase flow. 6. If two sensors with similar frequency are too near each other, separate them. 7. Purge the sensor tubes. 8. Perform Smart Meter Verification. 16.6.3 Unusually high density reading Cause • Plugged or coated sensor tube • Incorrect density calibration factors • Inaccurate temperature measurement • RTD failure • In high-frequency meters, erosion, or corrosion • In low-frequency meters, tube fouling Recommended actions 1. Ensure that all of the calibration parameters have been entered correctly. See the sensor tag or the calibration sheet for your meter. 2. Purge the sensor tubes. 3. Check for coating in the flow tubes. 4. Perform Smart Meter Verification. 182 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.6.4 Unusually low density reading Cause • Two-phase flow • Incorrect calibration factors • In low-frequency meters, erosion or corrosion Recommended actions 1. Check for alerts, especially Drive Overrange. 2. Check your process conditions against the values reported by the device. 3. Verify all of the characterization or calibration parameters. See the sensor tag or the calibration sheet for your meter. 4. Purge sensor tubes. 5. Check for tube erosion, especially if the process fluid is abrasive. 6. Perform Smart Meter Verification. 16.7 Discrete Output troubleshooting 16.7.1 No Discrete Output Cause • Output not powered • Wiring problem • Circuit failure Recommended actions 1. Check the power supply and power supply wiring if power source is set to external. 2. Verify the output wiring. 3. Verify that the channel is wired and configured as a Discrete Output. 4. Contact customer service. 16.7.2 Loop test failed Cause • Output not powered • Power supply problem • Wiring problem • Circuit failure Recommended actions 1. Check the power supply and power supply wiring. 2. Verify the output wiring. 3. Contact customer service. Configuration and Use Manual 183 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 16.7.3 Discrete Output readings reversed Cause • Wiring problem • Configuration does not match wiring Recommended actions 1. Verify the output wiring. 2. Ensure that Discrete Output Polarity is set correctly. 16.8 Flow measurement troubleshooting 16.8.1 Flow rate reported as zero when flow is present Cause • The process condition is below cutoff. • Two-phase flow Recommended action 1. Verify the cutoffs. 2. Check live density against the two-phase flow low and high limits. 16.8.2 Flow indication at no flow conditions or zero offset Cause • Misaligned piping (especially in new installations) • Open or leaking valve • Incorrect sensor zero Recommended actions 1. Verify all of the characterization or calibration parameters. See the sensor tag or the calibration sheet for your meter. 2. If the reading is not excessively high, review the live zero. You may need to restore the factory zero. 3. Check for open or leaking valves or seals. 4. Check for mounting stress on the sensor (e.g., sensor being used to support piping, misaligned piping). 5. Contact customer service. 16.8.3 Erratic non-zero flow rate at no-flow conditions Cause • Leaking valve or seal • Two-phase flow • Cutoff set to zero • Incorrect sensor orientation 184 Emerson.com Configuration and Use Manual MS-00809-0200-1600 • Wiring problem • Vibration in pipeline at rate close to sensor tube frequency • Damping value too low Troubleshooting May 2024 Recommended actions 1. Verify that the sensor orientation is appropriate for your application. See the installation manual for your sensor. 2. Check the drive gain and the pickoff voltage. 3. If the wiring between the sensor and the transmitter includes either a 4-wire or a 9-wire segment, verify that all the cable shields are correctly grounded. 4. Check the wiring between the sensor and the transmitter. 5. Verify zero after reviewing all of the above. If an auto is recommended, do so ONCE as close to normal operating conditions as possible. 6. Check cutoffs and enter an appropriate nonzero value. 7. For sensors with a junction box, check for moisture in the junction box. 8. Purge the sensor tubes. 9. Check for open or leaking valves or seals. 10. Check for sources of vibration. 11. Verify damping configuration. 12. Check for two-phase flow. 13. Check for radio frequency interference. 14. Contact customer service. 16.8.4 Erratic non-zero flow rate when flow is steady Cause • Two-phase flow • Damping value too low • Moisture in sensor or transmitter junction box • Wiring problem • Problem with receiving device Recommended actions 1. Verify that the sensor orientation is appropriate for your application. See the installation manual for your sensor. 2. Check the drive gain and the pickoff voltage. 3. If the wiring between the sensor and the transmitter includes either a 4-wire or a 9-wire segment, verify that all the cable shields are correctly grounded. 4. Check for air entrainment, tube fouling, flashing, or tube damage. 5. Perform a zero verification. 6. Verify measurement unit selection. 7. Check the wiring between the sensor and the transmitter. 8. For sensors with a junction box, check for moisture in the junction box. 9. Purge the sensor tubes. Configuration and Use Manual 185 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 10. Check for open or leaking valves or seals. 11. Check for sources of vibration. 12. Verify damping configuration. 13. Verify that the measurement units are configured correctly for your application. 14. Check for two-phase flow. 15. Check for radio frequency interference. 16. Contact customer service. 16.8.5 Inaccurate flow rate Cause • Wiring problem • Inappropriate measurement unit • Incorrect process variable selection • Incorrect measurement units • Incorrect flow calibration factor • Incorrect meter factor • Incorrect density calibration factors • Incorrect grounding • Two-phase flow • Problem with receiving device • Incorrect sensor zero Recommended actions 1. Check the wiring between the sensor and the transmitter. 2. Verify that the measurement units are configured correctly for your application. 3. Verify all of the characterization or calibration parameters. See the sensor tag or the calibration sheet for your meter. 4. Zero the meter. 5. Check the grounding of all components. 6. Check for two-phase flow. 7. Verify the receiving device, and the wiring between the transmitter and the receiving device. 8. Check the sensor coils for electrical shorts. If you find problems, replace the sensor. 9. Replace the core processor or transmitter. 16.9 Frequency Output troubleshooting 16.9.1 No Frequency Output Cause • Stopped totalizer • Process condition below cutoff 186 Emerson.com Configuration and Use Manual MS-00809-0200-1600 • Fault condition if Fault Action is set to Internal Zero or Downscale • Two-phase flow • Flow in reverse direction from configured flow direction parameter • Frequency Output Direction not set correctly • Bad frequency receiving device • Output level not compatible with receiving device • Bad output circuit • Output not powered • Wiring problem • Channel not configured for desired output Troubleshooting May 2024 Recommended actions 1. Verify that the process conditions are below the low-flow cutoff. Reconfigure the low-flow cutoff if necessary. 2. Check the Fault Action settings. 3. Verify that the totalizers are not stopped. A stopped totalizer will cause the Frequency Output to be locked. 4. Check for two-phase flow. 5. Check flow direction. 6. Check the direction parameters. 7. Verify expected frequency output signal using ProLink or by navigating to Service Tools → Service Data → View I/O levels. 8. Verify the receiving device, and the wiring between the transmitter and the receiving device. 9. Verify that the channel is wired and configured as a Frequency Output. 10. Perform a loop test with a multimeter or frequency counter. 16.9.2 Consistently incorrect Frequency Output measurement Cause • Output not scaled correctly • Incorrect measurement unit configured for process variable Recommended actions 1. Check the scaling of the Frequency Output. 2. Verify that the measurement units are configured correctly for your application. 16.9.3 Erratic Frequency Output Cause There is Radio Frequency Interference (RFI) from the environment. Recommended action Check for radio frequency interference. Configuration and Use Manual 187 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 16.9.4 Frequency Output goes in and out of fault conditions Cause There is a problem with the interaction between the Output Saturated alert and the fault action configured for the output. Recommended actions 1. Change the severity of the Output Saturated alert from Fault to another option. 2. Configure the transmitter to ignore the Output Saturated alert or the relevant conditions. 3. Change the configuration of Fault Action from Downscale to another option. 16.10 mA Output troubleshooting 16.10.1 No mA Output Cause • Output not powered • Power supply problem • Wiring problem • Circuit failure Recommended actions 1. If applicable, check the output wiring to verify that the output is powered. 2. Check the power supply and power supply wiring. 3. Verify the output wiring. 4. Check the Fault Action settings. 5. Verify channel configuration for the affected mA Output. 6. Measure DC voltage across output terminals to verify that the output is active. 7. Contact customer service. 16.10.2 Loop test failed Cause • Output not powered • Power supply problem • Wiring problem • Circuit failure Recommended actions 1. Check the power supply and power supply wiring. 2. Verify the output wiring. 3. Check the Fault Action settings. 4. Verify channel configuration for the affected mA Output. 5. Contact customer service. 188 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.10.3 mAO below 4 mA Cause • Output not powered • Open in wiring • Bad output circuit • Process condition below LRV • LRV and URV are not set correctly • Fault condition if Fault Action is set to Internal Zero or Downscale • Bad mA receiving device Recommended actions 1. Check your process conditions against the values reported by the device. 2. Verify the receiving device, and the wiring between the transmitter and the receiving device. 3. Check the settings of Upper Range Value and Lower Range Value. 4. Check the Fault Action settings. 5. Verify channel configuration for the affected mA Output. 16.10.4 Constant mAO Cause • Incorrect process variable assigned to the output • Fault condition exists • A loop test is in progress • Zero calibration failure • mA Output Direction not set correctly Recommended actions 1. Verify the output variable assignments. 2. View and resolve any existing alert conditions. 3. Check the direction parameters. 4. Check to see if a loop test is in process (the output is fixed). 5. If related to a zero calibration failure, reboot or power-cycle the transmitter and retry the zeroing procedure. 16.10.5 mAO consistently out of range Cause • Incorrect process variable or units assigned to output • Fault condition if Fault Action is set to Upscale or Downscale • LRV and URV are not set correctly Recommended actions 1. Verify the output variable assignments. Configuration and Use Manual 189 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 2. Verify the measurement units configured for the output. 3. Check the Fault Action settings. 4. Check the settings of Upper Range Value and Lower Range Value. 5. Check the mA Output trim. 16.10.6 Consistently incorrect mA measurement Cause • Loop problem • Incorrect measurement unit configured for process variable • Incorrect process variable configured • LRV and URV are not set correctly • mA Output Direction not set correctly Recommended actions 1. Check the mA Output trim. 2. Verify the measurement units configured for the output. 3. Verify the process variable assigned to the mA Output. 4. Check the direction parameters. 16.10.7 mAO correct at lower current, but incorrect at higher current Cause The mA loop resistance may be set too high. Recommended actions Verify that the mA Output load resistance is below the maximum supported load. See the installation manual for your transmitter. 16.10.8 mAO goes in and out of fault conditions Cause There is a problem with the interaction between the Output Saturated alert and the fault action configured for the output. Recommended actions 1. Identify and resolve the fault. 2. Verify that the mA Output load resistance is below the maximum supported load (600 ohms). 3. Configure the transmitter to ignore the Output Saturated alert or the relevant conditions. 4. Change the configuration of Fault Action from Downscale to another option. 16.11 Status alerts, causes, and recommendations Not all of these alerts may apply to your type of transmitter. 190 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.11.1 [002] RAM Error (Core Processor) Alert Fault - Electronics failed - Core ROM/RAM failure [002] Cause There is an internal memory problem with the core processor. This alert will not clear until you reboot or power cycle the transmitter. Recommended actions 1. Ensure that all wiring compartment covers are installed correctly. 2. Ensure that all transmitter wiring meets specifications and that all cable shields are properly terminated. 3. Ensure that all meter components are grounded properly. 4. Evaluate the environment for sources of high electromagnetic interference (EMI) and relocate the transmitter or wiring as necessary. 5. Reboot or power-cycle the transmitter to see if the alert clears. 6. Replace the core processor. 16.11.2 [003] Sensor Failed Alert Sensor Failed Cause Recommended actions 1. Check the drive gain and the pickoff voltage. 2. Check the wiring between the sensor and the transmitter. 3. Check the sensor coils to ensure the resistance readings are within specific sensor specifications. Contact Customer Support for specific sensor resistance values. If you find problems, replace the sensor. 4. Check the integrity of the sensor tubes. 5. Ensure that the sensor is completely full or completely empty. 6. Replace the sensor. 7. Contact customer service. 16.11.3 [005] Mass Flow Rate Overrange Alert Extreme Primary Purpose Variable Cause The measured flow is outside the sensor's flow limits. Recommended actions 1. Check your process conditions against the values reported by the device. 2. Verify that the transmitter is configured correctly for the connected sensor. 3. Check for two-phase flow. Configuration and Use Manual 191 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 Refer to Check for two-phase flow (slug flow). 4. Ensure the lower puck is seated to sensor feedthrough or junction box. 5. Contact customer service. 16.11.4 [008] Density Overrange Alert Density Overrange Cause • Tubes plugged • Incorrect density calibration parameters • Two-phase flow Recommended actions 1. If other alerts are present, resolve those alert conditions first. 2. Check your process conditions against the values reported by the device. 3. Check for two-phase flow by checking for two-phase alerts. If two-phase flow is the problem, alerts will be posted. 4. Contact customer service. 16.11.5 [009] Transmitter Initializing Alert Transmitter Initializing Cause • The transmitter is in power-up mode. • Insufficient DC startup current. Recommended actions 1. Allow the meter to complete its power-up sequence. The alert should clear automatically. 2. Verify that the DC power supply current is sufficiently rated for the device. 16.11.6 [010] Calibration Failed Alert Calibration Failure Cause The calibration failed. Recommended actions 1. Ensure that your calibration procedure meets the documented requirements. 2. Reboot or power-cycle the transmitter. 3. Retry the procedure. If it still fails, contact Customer Support. 192 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.11.7 [016] Sensor Temperature (RTD) Failure Alert Sensor Failed Cause • The value computed for the resistance of the line RTD is outside limits. • Open RTD or LLC Recommended actions 1. Check the wiring between the sensor and the transmitter. a) Refer to the installation manual and ensure that the wiring has been performed according to instructions. Obey all applicable safety messages. b) Verify that the wires are making good contact with the terminals. c) Perform RTD resistance checks and check for shorts to case. If you find problems, replace the sensor. d) Check the continuity of all wires from the transmitter to the sensor. 2. Check your process conditions against the values reported by the device. 3. Check the feedthrough pins. Contact customer service for assistance. If you find problems, replace the sensor. 4. Check the junction box for moisture, corrosion or oxidation. 5. Contact customer service. 16.11.8 [017] Sensor Case Temperature (RTD) Failure Alert Sensor Failed Cause • The values computed for the resistance of the meter and case RTDs are outside limits. • Open RTD Recommended actions 1. Check the wiring between the sensor and the transmitter. a) Refer to the installation manual and ensure that the wiring has been performed according to instructions. Obey all applicable safety messages. b) Verify that the wires are making good contact with the terminals. c) Perform RTD resistance checks and check for shorts to case. If you find problems, replace the sensor. d) Check the continuity of all wires from the transmitter to the sensor. 2. Check your process conditions against the values reported by the device. 3. Contact customer service. Configuration and Use Manual 193 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 16.11.9 [018] EEPROM Error (Transmitter) Alert Electronics Failed Cause There is an internal memory problem with the transmitter. Recommended actions 1. Power-cycle the transmitter to see if the alert clears. Important This alert will not clear until you cycle power to the meter. 2. Ensure that all wiring compartment covers are installed correctly. 3. Ensure that all wire connections are tight. 4. Ensure that all transmitter wiring meets specifications and that all cable shields are properly terminated. 5. Ensure that all meter components are grounded properly. 6. Evaluate the environment for sources of high electromagnetic interference (EMI) and relocate the transmitter or wiring as necessary. 7. If the alert persists, replace the transmitter. 8. Contact Customer Service. 16.11.10 [019] RAM Error (Transmitter) Alert Electronics Failed Cause There is a ROM checksum mismatch in the transmitter or the RAM address location cannot be written in the transmitter. This alert will not clear until you reboot or power cycle the transmitter. Recommended actions 1. Reboot or power-cycle the transmitter to see if the alert clears. 2. Ensure that all wiring compartment covers are installed correctly. 3. Ensure that all wire connections are tight. 4. Ensure that all transmitter wiring meets specifications and that all cable shields are properly terminated. 5. Ensure that all meter components are grounded properly. 6. Evaluate the environment for sources of high electromagnetic interference (EMI) and relocate the transmitter or wiring as necessary. 7. If the alert persists, contact Customer Service. 16.11.11 [020] Calibration Factors Missing Alert Configuration Error 194 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 Cause Some calibration factors have not been entered or are incorrect. Recommended actions 1. Verify characterization parameters (specifically Flow Cal Factor and K1 values). Refer to Characterize the meter (if required) . 2. Verify the setting of the Sensor Type parameter. 3. If Sensor Type = Curved Tube, ensure that no parameters specific to Straight Tube have been set. 4. Check the feedthrough pins. If you find problems, replace the sensor. Contact customer service for assistance. 5. Check the core processor housing for moisture, corrosion, or verdigris. 6. Check the junction box for moisture, corrosion, or verdigris. 7. Check the sensor coils for electrical shorts. If you find problems, replace the sensor. 16.11.12 [021] Incorrect Sensor Type Alert Configuration Error Cause Transmitter verification of sensor circuits and characterization has produced a discrepancy. The transmitter cannot operate the sensor. Recommended actions 1. Verify the setting of the Sensor Type parameter. 2. Verify characterization parameters (specifically Flow Cal Factor and K1 values). Refer to Characterize the meter (if required) . 3. Contact customer service. 16.11.13 [022] Configuration Database Corrupt Alert Electronics Failed Cause There is a NVM checksum mismatch in the core processor's configuration memory. Recommended actions 1. Reboot or power-cycle the transmitter to see if the alert clears. 2. Evaluate the environment for sources of high electromagnetic interference (EMI) and relocate the transmitter or wiring as necessary. 3. Ensure that all wiring compartment covers are installed correctly. 4. Ensure that all transmitter wiring meets specifications and that all cable shields are properly terminated. 5. Check the drain wires. a) Verify that the drain wires from either 4-wire or the 9-wire cable are all properly landed. 6. Ensure that all meter components are grounded properly. Configuration and Use Manual 195 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 7. If the alert persists, replace the lower puck. 16.11.14 [024] Program Corrupt (Core Processor) Alert Electronics Failed Cause There is a checksum mismatch in the core processor's program section. Recommended actions 1. Reboot or power-cycle the transmitter to see if the alert clears. 2. Evaluate the environment for sources of high electromagnetic interference (EMI) and relocate the transmitter or wiring as necessary. 3. Ensure that all wiring compartment covers are installed correctly. 4. Ensure that all transmitter wiring meets specifications and that all cable shields are properly terminated. 5. Check the drain wires. a) Verify that the drain wires from either 4-wire or the 9-wire cable are all properly landed. 6. Ensure that all meter components are grounded properly. 7. If the alert persists, replace the lower puck. 16.11.15 [026] Sensor/Transmitter Communications Failure Alert Configuration Error Cause The transmitter has lost communication with the core processor, or there have been too many communications errors. Recommended actions 1. Check the wiring between the sensor and the transmitter. 2. Verify the power to both the transmitter and core processor. 3. Cycle power to the transmitter. 4. If the problem persists, contact customer support. 16.11.16 [028] Core Process Write Failure Alert Core Process Write Failure Cause A write to the core processor failed. Recommended actions 1. Reboot or power-cycle the transmitter to see if the alert clears. 2. Contact customer service about servicing or replacing the core processor or transmitter. 196 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.11.17 [030] Incorrect Board Type Alert Configuration Error Cause The firmware or configuration loaded in the transmitter is incompatible with the board type. Recommended actions 1. If this alarm occurred in conjunction with an effort to load a configuration into the transmitter, confirm that the transmitter is of the same model as the one the configuration came from. 2. Reboot or power-cycle the transmitter to see if the alert clears. 3. If the problem persists, contact customer service. 16.11.18 [031] Low Power Alert Core Low Power Cause The enhanced core processor is not receiving sufficient power. This alert will not clear until you reboot or power cycle the transmitter. Recommended actions 1. Check the wiring between the sensor and the transmitter. 2. Measure the voltage at the core processor terminals and ensure that it is receiving a minimum of 11.5 volts at all times. If it is not, verify the power wiring to the transmitter. 3. Verify that the transmitter is receiving sufficient power. a) If it is not, correct the problem and reboot or power-cycle the transmitter. b) If it is, this suggests that the transmitter has an internal power issue. Replace the transmitter. 16.11.19 [033] Insufficient Pickoff Signal Alert Tube Not Full Cause The signal from the sensor pickoffs is insufficient for operation (enhanced core processor only). Recommended actions 1. Check for two-phase flow. 2. Check the sensor tubes for plugging or coating. 3. Check for shorts to the sensor case. See Check the sensor coils, Step 4. 4. Check for fluid separation by monitoring the density value and comparing the results against expected density values. 5. Ensure that the sensor orientation is appropriate for your application. Settling from a two-phase or three-phase fluid can cause this alert even if the flow tubes are full. Configuration and Use Manual 197 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 16.11.20 [034] Smart Meter Verification Failed Alert Function Check Failed and Smart Meter Verification Failed Cause The current Smart Meter Verification value is statistically different than the factory baseline value. Recommended actions 1. Minimize process instability and repeat the test. 2. Contact Customer Service. 16.11.21 [035] Smart Meter Verification Aborted Alert Function Check Failed and Smart Meter Verification Aborted Cause The Smart Meter Verification test did not complete, possibly because it was manually aborted or because process conditions were too unstable. Recommended actions 1. Minimize process instability and repeat the test. 2. Check the Smart Meter Verification abort code and take appropriate steps. 3. Contact customer service. Table 16-2: SMV aborts code 198 Abort code Abort reason Abort recommendation 1 Manual abort by end user Not available 2 SMV timeout Check status of pickoff and drive coils. 3 Pickoff Voltage low Check status of pickoff and drive coils. 4 Temperature unstable Ensure temperature is stable. Start again. 5 Cal state in progress Not available 6 Unused Not available 7 Drive loop AGC reported an amplitude error Check status of pickoff and drive coils. 8 High flow (dt) standard deviation Reduce flow rate and start again. 9 High flow (dt) mean value Reduce flow rate and start again. 10 State in progress Not available 11 Verification complete Not available 12 Transmitter in fault Clear alarms before proceeding. 13 No factory air verification Perform factory calibration on air. 14 No factory water verification Perform factory calibration on water. 15 Drive frequency drift from carrier frequency Ensure temperature, flow, and density are stable. Start again. Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.11.22 [102] Drive Overrange Alert Drive Over-Range Cause The drive power (current/ voltage) is at its maximum. Recommended actions 1. Verify that the tubes are full of process fluid. 2. Check flow, density and temperature against the values reported by the device. 3. For liquid applications, check for partially filled tubes. For gas applications, check for condensate, compressor oil, etc. 4. Check for foreign material in the tubes, coating on tube walls, or other process problems. 5. Check the drive gain and the pickoff voltage. Refer to Check the pickoff voltage. 6. Check sensor coil resistance readings. If you find problems, replace the sensor. Refer to Check for internal electrical problems. 7. Ensure that the sensor orientation is appropriate for your application. Check your sensor installation manual for proper orientation. Settling from a two-phase or three-phase fluid can cause this alert even if the flow tubes are full. 16.11.23 [104] Calibration in Progress Alert Function Check in Progress Cause A calibration is running. Recommended actions Allow the test to complete. 16.11.24 [105] Two-Phase Flow Alert Process Aberration Cause Recommended actions Check for two-phase flow. Refer to Configure Lower Range Value (LRV) and Upper Range Value (URV) for an mA Output. 16.11.25 [110] Frequency Output 1 Saturated Alert Output Saturated Configuration and Use Manual 199 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 Cause The calculated output value is outside the range of the output. Recommended actions 1. Check the scaling of the Frequency Output. 2. Check your process conditions against the values reported by the device. 3. Ensure that both devices are using the same measurement unit. 4. Purge the sensor tubes. 16.11.26 [111] Frequency Output 1 Fixed Alert Output Fixed Cause The output is configured to send a constant value. A frequency output test is in progress. Recommended actions Check to see if a frequency output test is in progress. If so, unfix the output. 16.11.27 [116] Temperature Overrange (API Referral) Alert Process Aberration Cause The line temperature is outside the range of the API table. Recommended actions 1. Ensure that process temperature is within the range of the API table. 2. Verify the configuration of the API Referral application and related parameters. 16.11.28 [117] Density Overrange (API Referral) Alert Process Aberration Cause The line density is outside the range of the API table. Recommended actions 1. Ensure that process density is within the range of the API table. 2. Verify the configuration of the API Referral application and related parameters. 16.11.29 [118] Discrete Output 1 Fixed Alert Output Fixed 200 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 Cause The output is set to a constant state. An output test is in progress. Recommended actions Check to see if an output test is in progress. If so, unfix it. 16.11.30 [120] Curve Fit Failure (Concentration) Alert Configuration Error Cause One or more errors in the concentration curve input Recommended actions 1. Verify the configuration of the concentration measurement application. 2. Ensure the density and temperature units match those that the curve was written in. 3. Contact customer service. 16.11.31 [121] Extrapolation Alert (Concentration) Alert Process Aberration Cause The line density or line temperature is outside the range of the concentration matrix plus the configured extrapolation limit. Recommended actions 1. Verify the configuration of the concentration measurement application. 2. Ensure the live density and temperature readings fall within limits of the matrix being used. 16.11.32 [123] Pressure Overrange (API Referral) Alert Process Aberration Cause The external line pressure is outside the range of the API table. Recommended actions 1. Ensure that process pressure is within the range of the API table. 2. Verify the configuration of the API Referral application and related parameters. 3. Ensure the transmitter's external pressure engineering unit matches that of the actual external pressure device. Configuration and Use Manual 201 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 16.11.33 [131] Smart Meter Verification in Progress Alert Function Check in Progress Cause A Smart Meter Verification test is running. This can take up to 2 minutes. Recommended actions Allow the test to complete. 16.11.34 [132] Sensor Simulation Active Alert Sensor Being Simulated Cause Sensor simulation mode is enabled. Recommended actions Disable sensor simulation. 16.11.35 [138] Transient Bubble Remediation (TBR) Active Alert Process Aberration Cause Drive gain is above the configured threshold and transient bubble remediation is active. Recommended actions Check for air entrainment, tube fouling, flashing, or tube damage. 16.11.36 Batcher Not Configured Alert Configuration Error Cause One or more of the following has occurred: • No flow source has been configured for the batcher application • The batch target is 0 • No Discrete Output is assigned to batch control Recommended actions Verify the configuration of the batcher application and related parameters. 202 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.11.37 Batch Time Out Alert Process Aberration Cause The batch exceeded Maximum Batch Time, and ended before the target was reached. Recommended actions Verify the configuration of the batcher application and related parameters. 16.11.38 Clock Failure Alert Maintenance required - Configuration warning - Clock constant Cause The transmitter real-time clock is not incrementing. Recommended actions 1. Contact customer service. 2. Replace hardware board. 16.11.39 Core Processor Update Failed Alert Configuration Error Cause The core processor software update failed. Recommended actions 1. Resolve any active alerts. 2. Check connection between the upper and lower pucks. 3. Reboot or power-cycle the transmitter, then retry the procedure. If it still fails, replace the transmitter. 4. Contact customer service. 16.11.40 mA Output Fixed Alert Function check - output fixed - [114] mA output fixed Cause The output is configured to send a constant value. A loop test may be in progress. Non-zero HART multidrop address Recommended actions 1. Check to see if a loop test is in process (the output is fixed). Configuration and Use Manual 203 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 2. Exit mA Output trim, if applicable. 3. Reset HART multidrop address to zero. 4. Cycle power. 16.11.41 mA Output Saturated Alert Out of specification - output saturated - mA output saturated [100 or 113] Cause The calculated output value is outside the range of the output. Recommended actions 1. Check the settings of Upper Range Value and Lower Range Value. Refer to Configure Lower Range Value (LRV) and Upper Range Value (URV) for an mA Output. 2. Check your process conditions against the values reported by the device. 3. Ensure that both devices are using the same measurement unit. 4. Purge the sensor tubes. 16.11.42 Enhanced Event X Active Alert Out of specification - Event active - Discrete event X active Cause The conditions assigned to any enhanced event (Enhanced Event 1 through Enhanced Event 5) are present. Recommended actions 1. If this is an accurate indication of process conditions, no action is required. The alert will clear when the process returns to normal. 2. Review event configuration if you believe the event was triggered erroneously. 16.11.43 Event X Active Alert Out of specification - Event active - Event X active [108, 109] Cause The conditions assigned to either Basic Event 1 or Basic Event 2 are present. Recommended actions 1. If this is an accurate indication of process conditions, no action is required. The alert will clear when the process returns to normal. 2. Review event configuration if you believe the event was triggered erroneously. 16.11.44 Moderate Two Phase Flow Alert Process Aberration 204 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 Cause The transmitter has detected moderate two-phase flow. Recommended actions Check your process conditions against the values reported by the device. 16.11.45 No Permanent License Alert Configuration warning Cause A permanent license has not been installed in the transmitter firmware. Recommended actions 1. If you have a permanent license, install it. 2. If you do not have a permanent license, contact customer service. 16.11.46 Password Not Set Alert Configuration Error Cause Display security has been enabled but the display password has not been changed from the default value. Recommended actions Configure a password or disable display security. 16.11.47 Severe Two Phase Flow Alert Process Aberration Cause The transmitter has detected severe two-phase flow. Recommended actions Check your process conditions against the values reported by the device. 16.11.48 Time Not Entered Alert Configuration Error Cause The system time has not been entered. The system time is required for diagnostic logs. Recommended actions Set the system time. Configuration and Use Manual 205 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 16.11.49 Transmitter Software Update Failed Alert Configuration Error Cause The transmitter software update failed. Recommended actions 1. Reboot or power-cycle the transmitter. 2. Retry the procedure. 3. Contact customer service. 16.11.50 Watchdog Error Alert Electronics Failed Cause The watchdog timer has expired. Recommended actions The transmitter will power cycle when a watchdog error is detected and will increment the watchdog error count. If this happens multiple times, contact customer support. 16.12 Check the cutoffs If the transmitter cutoffs are configured incorrectly, the transmitter may report zero flow when flow is present, or very small amounts of flow under no-flow conditions. The cutoff is considered an absolute value for reporting positive or negative flow. Procedure Verify the configuration of all cutoffs. 16.13 Check the direction parameters If the direction parameters are set incorrectly, flow rate may be reported as reverse when it is actually forward, or vice versa. Totalizers and inventories may increment when they should decrement, or vice versa. The reported flow rate and flow totals depend on the interaction of four factors: the flow direction arrow on the sensor, actual flow direction, the Sensor Flow Direction Arrow parameter, the Direction parameter for the mA output or the frequency output, and the Totalizer Direction parameter. Procedure 1. Ensure that Sensor Flow Direction Arrow is set correctly for your sensor installation and your process. 2. Verify the configuration of mA Output Direction, Frequency Output Direction, and Totalizer Direction. 206 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.14 Check the drive gain Excessive or erratic drive gain may indicate any of a variety of process conditions or sensor problems. To know whether your drive gain is excessive or erratic, you must collect drive gain data during the problem condition and compare it to drive gain data from a period of normal operation. Excessive (saturated) drive gain Table 16-3: Possible causes and recommended actions for excessive (saturated) drive gain Possible cause Recommended actions Bent sensor tube Check the pickoff voltages (see Check the pickoff voltage). If either of them are close to zero (but neither is zero), the sensor tubes may be bent. The sensor will need to be replaced. Cracked sensor tube Replace the sensor. Flow rate out of range Verify calibration factors are correct. Open drive or pickoff sensor coil Contact customer support. Over-pressurized tubes Replace the sensor. Plugged sensor tube A dull, audible hum, and unusually high sensor vibration is usually accompanied by high, even saturated, drive gain. Check the pickoff voltages (see Check the pickoff voltage). If either of them are close to zero (but neither is zero), plugged tubes may be the source of your problem. Purge the tubes. In extreme cases, you may need to replace the sensor. Sensor case full of process fluid Replace the sensor. Sensor imbalance Contact customer support. Sensor tubes not completely full Correct process conditions so that the sensor tubes are full. Two-phase flow Check for two-phase flow. See Check for two-phase flow (slug flow). Vibrating element not free to vibrate Ensure that the vibrating element is free to vibrate. Erratic drive gain Table 16-4: Possible causes and recommended actions for erratic drive gain Possible cause Recommended actions Foreign material caught in sensor tubes • Purge the sensor tubes. • Replace the sensor. Internal sensor damage Replace the sensor. 16.15 Check for internal electrical problems Shorts between sensor terminals or between the sensor terminals and the sensor case can cause the sensor to report false or erroneous readings. Possible cause Recommended action Moisture inside the sensor junction box Ensure that the junction box is dry and no corrosion is present. Liquid or moisture inside the sensor case Contact customer support. Configuration and Use Manual 207 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 Possible cause Recommended action Internally shorted feedthrough Contact customer support. Faulty cable Replace the cable. Improper wire termination Verify wire terminations inside the sensor junction box. See Micro Motion 9-Wire Flowmeter Cable Preparation and Installation Manual. Shorts to the housing created by trapped or damaged wires Contact customer support. Loose wires or connectors Contact customer support. Liquid or moisture inside the housing Contact customer support. 16.16 Check Frequency Output Fault Action The Frequency Output Fault Action controls the behavior of the Frequency Output if the transmitter encounters an internal fault condition. If the Frequency Output is reporting a constant value, the transmitter may be in a fault condition. Procedure 1. Check the status alerts for active fault conditions. 2. If there are active fault conditions, the transmitter is performing correctly. If you want to change its behavior, change the setting of Frequency Output Fault Action. 3. If there are no active fault conditions, continue troubleshooting. 16.17 Check the scaling of the Frequency Output If the process variable assigned to the Frequency Output goes to a value that would set the Frequency Output to a signal below 0 Hz or above 12500 Hz, the meter will post an Output Saturated alert for the affected output, then perform the configured fault action. Procedure 1. Record your current process conditions. 2. Adjust the scaling of the Frequency Output. 16.18 Check grounding A 9-wire remote mount transmitter and sensor must be grounded. Prerequisites You will need an: • Installation manual for your sensor • Installation manual for your transmitter (remote-mount installations only) Procedure Refer to the sensor and transmitter installation manuals for grounding requirements and instructions. 208 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 16.19 Perform transmitter output tests A loop test is a way to verify that the transmitter and the remote device are communicating properly. A loop test also helps you know whether you need to trim mA Outputs. Prerequisites Follow appropriate procedures to ensure that testing will not interfere with existing measurement and control loops. 16.19.1 Perform a mA loop test using the display Prerequisites Before performing an mA loop test, configure Channel B as an mA Output. Follow appropriate procedures to ensure that testing will not interfere with existing measurement and control loops. Procedure 1. Choose Menu → Service Tools → Output Simulation and select the mA Output. 2. Set Simulation Value to 4. 3. Start the simulation. 4. Read the mA current at the receiving device and compare it to the transmitter output. The readings do not need to match exactly. If the values are slightly different, you can correct the discrepancy by trimming the output. 5. Choose New Value. 6. Set Simulation Value to 20. 7. Start the simulation. 8. Read the mA current at the receiving device and compare it to the transmitter output. The readings do not need to match exactly. If the values are slightly different, you can correct the discrepancy by trimming the output. 9. Choose Exit. Postrequisites • If the mA Output readings are within 200 microamps of each other, you can correct this discrepancy by trimming the output. • If the discrepancy between the mA Output readings is greater than 200 microamps, or if at any step the reading was faulty, verify the wiring between the transmitter and the remote device, and try again. • You must end the test. It will not time out by itself. A power cycle will also end the test. 16.19.2 Perform a Frequency Output test using the display Prerequisites Before performing a Frequency Output test, configure Channel B as a Frequency Output. Follow appropriate procedures to ensure that testing will not interfere with existing measurement and control loops. Procedure 1. Choose Menu → Service Tools → Output Simulation and select the Frequency Output. 2. Set Simulation Value to 1. Configuration and Use Manual 209 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 3. Start the simulation. 4. Read the frequency signal at the receiving device and compare it to the transmitter output. 5. Choose New Value. 6. Set Simulation Value to 14500. 7. Start the simulation. 8. Read the frequency signal at the receiving device and compare it to the transmitter output. 9. Choose Exit. 16.19.3 Perform a Discrete Output test using the display Prerequisites Before performing a Discrete Output test, configure Channel B as a Discrete Output. Follow appropriate procedures to ensure that testing will not interfere with existing measurement and control loops. Procedure 1. Choose Menu → Service Tools → Output Simulator and select the Discrete Output. 2. Set Simulation Value to ON. 3. Start the simulation. 4. Verify the signal at the receiving device. 5. Choose New Value. 6. Set Simulation Value to OFF. 7. Start the simulation. 8. Verify the signal at the receiving device. 9. Choose Exit. Postrequisites • If the Discrete Output readings are reversed, check the setting of Discrete Output Polarity. • You must end the test. It will not time out by itself. A power cycle will also end the test. 16.19.4 Perform an mA loop test using ProLink III Prerequisites Before performing an mA loop test, configure Channel B as an mA Output. Follow appropriate procedures to ensure that testing will not interfere with existing measurement and control loops. Procedure 1. Choose Device Tools → Diagnostics → Testing and select the mA Output test. 2. Enter 4 in Fix to:. 3. Select Fix mA. 4. Read the mA current at the receiving device and compare it to the transmitter output. The readings do not need to match exactly. If the values are slightly different, you can correct the discrepancy by trimming the output. 5. Enter 20 in Fix to:. 6. Select Fix mA. 210 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 7. Read the mA current at the receiving device and compare it to the transmitter output. The readings do not need to match exactly. If the values are slightly different, you can correct the discrepancy by trimming the output. 8. Select UnFix mA. Postrequisites • If the mA Output readings are within 20 microamps of each other, you can correct this discrepancy by trimming the output. • If the discrepancy between the mA Output readings is greater than 20 microamps, or if at any step the reading was faulty, verify the wiring between the transmitter and the remote device, and try again. • You must end the test. It will not time out by itself. A power cycle will also end the test. 16.19.5 Perform a Frequency Output test using ProLink III Prerequisites Before performing a Frequency Output test, configure Channel B as a Frequency Output. Follow appropriate procedures to ensure that testing will not interfere with existing measurement and control loops. Procedure 1. Choose Device Tools → Diagnostics → Testing and select the Frequency Output test. 2. Enter the Frequency Output value in Fix to. 3. Select Fix FO. 4. Read the frequency signal at the receiving device and compare it to the transmitter output. 5. Select UnFix FO. Postrequisites You must end the test. It will not time out by itself. A power cycle will also end the test. 16.19.6 Perform a Discrete Output tests using ProLink III Prerequisites Before performing a Discrete Output test, configure Channel B as a Discrete Output. Follow appropriate procedures to ensure that testing will not interfere with existing measurement and control loops. Procedure 1. Choose Device Tools → Diagnostics → Testing → Discrete Output Test. 2. If your transmitter is configured for two or more Discrete Outputs, determine which Discrete Output you want to test. 3. Set Fix To: to ON. 4. Verify the signal at the receiving device. 5. Set Fix To: to OFF. 6. Verify the signal at the receiving device. 7. Select UnFix. Postrequisites • If the Discrete Output readings are reversed, check the setting of Discrete Output Polarity. Configuration and Use Manual 211 Troubleshooting May 2024 • Configuration and Use Manual MS-00809-0200-1600 You must end the test. It will not time out by itself. A power cycle will also end the test. 16.20 Check Lower Range Value and Upper Range Value If the process variable assigned to the mA Output falls below the configured Lower Range Value (LRV) or rises above the configured Upper Range Value (URV), the meter will post an Output Saturated alert for the affected output, then perform the configured fault action. Procedure 1. Record your current process conditions. 2. Check the configuration of the LRV and URV. 16.21 Check mA Output Fault Action The mA Output Fault Action controls the behavior of the mA Output if the transmitter encounters an internal fault condition. If the mA Output is reporting a constant value below 4 mA or above 20 mA, the transmitter may be in a fault condition. Procedure 1. Check the status alerts for active fault conditions. 2. If there are active fault conditions, the transmitter is performing correctly. If you want to change its behavior, change the setting of mA Output Fault Action. 3. If there are no active fault conditions, continue troubleshooting. 16.22 Trim mA Output Trimming an mA Output calibrates the transmitter mA Output to the receiving device. If the current trim value is inaccurate, the transmitter will under-compensate or over-compensate the output. 16.22.1 Trim an mA Output using the display Trimming the mA Output establishes a common measurement range between the transmitter and the device that receives the mA Output. Prerequisites Ensure that the mA Output is wired to the receiving device that will be used in production. Procedure 1. Choose Menu → Service Tools → mA Output Trim → mA Output 1. 2. Follow the instructions in the guided method. 3. Check the trim results. If any trim result is less than −20 microamps or greater than +20 microamps, contact customer service. 16.22.2 Trim mA Output using ProLink III Trimming the mA Output establishes a common measurement range between the transmitter and the device that receives the mA Output. Prerequisites Ensure that the mA Output is wired to the receiving device that will be used in production. 212 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 Procedure 1. Follow the instructions in the guided method. 2. Check the trim results. If any trim result is less than −20 microamps or greater than +20 microamps, contact customer service. 16.23 Check HART communications If you cannot establish or maintain HART communications, or if the primary mA Output is producing a fixed value, you may have a wiring problem or a HART configuration problem. Prerequisites You may need one or more of the following: • The installation manual for your transmitter • A field communicator • A voltmeter • Optional: The HART Application Guide. Procedure 1. Verify the HART address. Tip The default HART address is 0. This is the recommended value unless the device is in a multidrop network. 2. If the primary mA Output is producing a fixed value of 4 mA, ensure that mA Output Action (Loop Current Mode) is enabled. For all HART addresses except 0, mA Output Action must be enabled to allow the primary mA Output to report process data. 3. Refer to the wiring diagrams in the installation manual and verify that the primary mA Output is correctly wired for HART support. 16.24 Check the pickoff voltage If the pickoff voltage readings are unusually low, you may have any of a variety of process or equipment problems. To know whether your pickoff voltage is unusually low, you must collect pickoff voltage data during the problem condition and compare it to pickoff voltage data from a period of normal operation. Drive gain and pickoff voltage are inversely proportional. As drive gain increases, pickoff voltages decrease and vice versa. Table 16-5: Possible causes and recommended actions for low pickoff voltage Possible cause Recommended actions Faulty wiring runs between the sensor and transmitter Verify wiring between sensor and transmitter. Process flow rate beyond the limits of the sensor Verify that the process flow rate is not out of range of the sensor. Configuration and Use Manual 213 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 Table 16-5: Possible causes and recommended actions for low pickoff voltage (continued) Possible cause Recommended actions Sensor tubes are not vibrating • Check for plugging or deposition. • Ensure that the vibrating element is free to vibrate (no mechanical binding). • Verify wiring. Moisture in the sensor electronics Eliminate the moisture in the sensor electronics. The sensor is damaged Replace the sensor. Two-phase flow Ensure the sensor tubes are full. 16.25 Check power supply wiring If the power supply wiring is damaged or improperly connected, the transmitter may not receive enough power to operate properly. Prerequisites • You will need the installation manual for your transmitter. Procedure 1. Use a voltmeter to test the voltage at the transmitter power supply terminals. • If the voltage is within the specified range, you do not have a power supply problem. 2. • If the voltage is low, ensure that the power supply is adequate at the source, the power cable is sized correctly, there is no damage to the power cable, and an appropriate fuse is installed. • If there is no power, continue with this procedure. WARNING If the transmitter is in a hazardous area, wait five minutes after disconnecting the power. Failure to do so could result in an explosion causing death or injury. Before inspecting the power supply wiring, disconnect the power source. 3. Ensure that the terminals, wires, and wiring compartment are clean and dry. 4. Ensure that the power supply wires are connected to the correct terminals. 5. Ensure that the power supply wires are making good contact, and are not clamped to the wire insulation. 6. WARNING If the transmitter is in a hazardous area, do not reapply power to the transmitter with the housing cover removed. Reapplying power to the transmitter while the housing cover is removed could cause an explosion. Reapply power to the transmitter. 7. Test the voltage at the terminals. If there is no power, contact customer service. 16.26 Check for radio frequency interference (RFI) The transmitter Frequency Output or Discrete Output can be affected by radio frequency interference (RFI). Possible sources of RFI include a source of radio emissions, or a large transformer, pump, or motor that can 214 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 generate a strong electromagnetic field. Several methods to reduce RFI are available. Use one or more of the following suggestions, as appropriate to your installation. Procedure • Use shielded cable between the output and the receiving device. — Terminate the shielding at the receiving device. If this is impossible, terminate the shielding at the cable gland or conduit fitting. — Do not terminate the shielding inside the wiring compartment. — 360-degree termination of shielding is unnecessary. • Eliminate the RFI source. • Move the transmitter. 16.27 Checking process variables Micro Motion suggests that you make a record of the process variables listed below, under normal operating conditions. This list will help you recognize when the process variables are usually high or low. • Flow rate • Density • Temperature • Tube frequency • Pickoff voltage • Drive gain For troubleshooting, check the process variables under both normal flow and tubes-full no-flow conditions. Except for flow rate, you should see little or no change between flow and no-flow conditions. If you see a significant difference, record the values and contact customer service for assistance. Unusual values for process variables may indicate a variety of different problems. The following table lists several possible problems and suggested remedies. Table 16-6: Process variables problems and remedies Symptom Cause Suggested remedy Steady non-zero flow rate under no-flow conditions Misaligned piping (especially in new installations) Correct the piping. Open or leaking valve Check or correct the valve mechanism. Bad sensor zero Rezero the flow meter. See Zero the meter. Configuration and Use Manual 215 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 Table 16-6: Process variables problems and remedies (continued) Symptom Cause Suggested remedy Erratic non-zero flow rate under no-flow conditions Leaking valve or seal Check pipeline Slug flow See Check for two-phase flow (slug flow). Plugged flow tube Check drive gain and tube frequency. Purge the flow tubes. Incorrect sensor orientation Sensor orientation must be appropriate to the process fluid. See the installation manual for your sensor. Wiring problem Check the sensor circuitry. See Check for internal electrical problems. Vibration in pipeline at rate close to sensor tube frequency Check the environment and remove the source of the vibration. Damping value too low Check the configuration. See the appropriate section: • Configure Flow Damping Mounting stress on sensor Erratic non-zero flow rate when flow is steady 216 • Configure Density Damping • Configure Temperature Damping Check the sensor mounting to ensure: • Sensor is not being used to support the pipe • Sensor is not being used to correct pipe misalignment • Sensor is not too heavy for pipe Sensor cross-talk Check the environment for sensor with a similiar (±0.5 Hz) tube frequency. Slug flow See Check for two-phase flow (slug flow). Damping value too low Check the configuration. See Characterize the meter (if required). Plugged flow tube • Check drive gain and tube frequency. • Purge the flow tubes. Excessive or erratic drive gain See Check the drive gain. Output wiring problem Verify wiring between transmitter and receiving device. See the installation manual for your transmitter. Problem with receiving device Test with another receiving device. Wiring problem Check the sensor circuitry. See Check for internal electrical problems. Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 Table 16-6: Process variables problems and remedies (continued) Symptom Cause Suggested remedy Inaccurate flow rate or batch rate Bad flow calibration factor Verify characterization. See Characterize the meter (if required). Inappropriate measurement unit Check calibration. Bad sensor zero Resize the flow meter. See Zero the meter. Bad density calibration factors Verify characterization. See Characterize the meter (if required). Bad flow meter grounding See Check grounding. Slug flow See Check for two-phase flow (slug flow). Problem with receiving device Test with another receiving device. Wiring problem Check the sensor circuitry. See Check for internal electrical problems. Problem with process fluid Use standard procedures to check the quality of the process fluid. Bad density calibration factors Verify characterization. See Characterize the meter (if required). Wiring problem Check the sensor circuitry. See Check for internal electrical problems. Bad flow meter grounding Check the sensor circuitry. See Check grounding. Slug flow Check the environment for sensor with a similar (±0.5 Hz) tube frequency. Sensor cross-talk Check the sensor circuitry. See Check for internal electrical problems. Plugged flow tube Check drive gain and tube frequency. Purge the flow tubes. Incorrect sensor orientation Sensor orientation must be appropriate to process fluid. See the installation manual for your sensor. RTD failure Check for alarm conditions and follow the troubleshooting procedure for the indicated alarm. Physical characteristics of the sensor have changed Check for corrosion, erosion, or tube damage. Temperature reading significantly different from process temperature RTD failure Check for alarm conditions and follow troubleshooting procedure for indicated alarm. Temperature reading slightly different from process temperature Sensor leaking heat Insulate the sensor. Unusually high density reading Plugged flow tube Check drive gain and tube frequency. Purge the flow tubes. Incorrect K2 value Verify characterization. See Characterize the meter (if required). Inaccurate density reading Configuration and Use Manual 217 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 Table 16-6: Process variables problems and remedies (continued) Symptom Cause Suggested remedy Unusually low density reading Slug flow Use standard procedures to check the quality of the process fluid. Incorrect K2 value Verify characterization. See Characterize the meter (if required). Unusually high tube frequency Sensor erosion Contact customer service. Unusually low pickoff voltages Plugged fow tube, corrosion, or erosion Purge the flow tubes. Unusually low pickoff voltages Several possible causes See Check the pickoff voltage. Unusually high drive gain Several possible causes See Check the drive gain. 16.28 Check sensor-to-transmitter wiring A number of power-supply and output problems may occur if the wiring between the sensor and the transmitter is improperly connected, or if the wiring becomes damaged. Be sure to check all wiring segments: • If you have a 9-wire transmitter, check the wiring between the transmitter and the sensor junction box. Prerequisites You will need the installation manual for your transmitter. Procedure 1. Before opening the wiring compartments, disconnect the power source. WARNING If the transmitter is in a hazardous area, wait five minutes after disconnecting the power. Failure to do so could result in an explosion causing death or injury. 2. Verify that the transmitter is connected to the sensor according to the information provided in the installation manual. 3. Ensure the lower puck is fully seated on the feed-through pins. 4. Verify that the wires are making good contact with the terminals. 5. Check the continuity of all wires from the transmitter to the sensor. 16.29 Using sensor simulation for troubleshooting Display Menu → Service Tools → Sensor Simulation ProLink III Device Tools → Diagnostics → Testing → Sensor Simulation When sensor simulation is enabled, the transmitter reports user-specified values for basic process variables. This allows you to reproduce various process conditions or to test the system. You can use sensor simulation to help distinguish between legitimate process noise and externally caused variation. For example, consider a receiving device that reports an unexpectedly erratic density value. If sensor simulation is enabled and the observed density value does not match the simulated value, the source of the problem is likely to be somewhere between the transmitter and the receiving device. You can enable sensor simulation using either the display or ProLink III software. 218 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Troubleshooting May 2024 Important When sensor simulation is active, the simulated value is used in all transmitter outputs and calculations, including totals and inventories, volume flow calculations, and concentration calculations. Disable all automatic functions related to the transmitter outputs and place the loop in manual operation. Do not enable simulation mode unless your application can tolerate these effects, and be sure to disable simulation mode when you have finished testing. A power cycle will end sensor simulation. 16.30 Check for two-phase flow (slug flow) Two-phase flow can cause rapid changes in the drive gain. This can cause a variety of measurement issues. Procedure 1. Check for two-phase flow alerts (e.g., A105). If the transmitter is not generating two-phase flow alerts, verify that two-phase flow limits have been set. If limits are set, two-phase flow is not the source of your problem. 2. Check the process for cavitation, flashing, or leaks. 3. Monitor the density of your process fluid output under normal process conditions. 4. Check the settings of Two-Phase Flow Low Limit, Two-Phase Flow High Limit, and Two-Phase Flow Timeout. Tip You can reduce the occurrence of two-phase flow alerts by setting Two-Phase Flow Low Limit to a lower value, Two-Phase Flow High Limit to a higher value, or Two-Phase Flow Timeout to a higher value. For most liquid applications, leaving the Two-Phase Flow High Limit at 5.0 g/cc will suffice. 16.31 Check the sensor coils Checking the sensor coils can identify a cause for a no sensor response alert. Restriction This procedure applies only to 9-wire remote-mount transmitters. For integral mount transmitters, consult the factory. Procedure 1. Disconnect power to the transmitter. WARNING If the transmitter is in a hazardous area, wait five minutes after disconnecting the power. Failure to do so could result in an explosion causing death or injury. 2. Remove the wires from the sensor junction box. 3. Using a digital multimeter (DMM), check the pickoff coils by placing the DMM leads on the unplugged terminal blocks for each terminal pair. See Table 16-7 for a list of the coils. Record the values. Table 16-7: Coils and test terminal pairs Coil Sensor model Terminal colors Drive coil All Brown to red Left pickoff coil (LPO) All Green to white Right pickoff coil (RPO) All Blue to gray Resistance temperature detector (RTD) All Yellow to violet Configuration and Use Manual 219 Troubleshooting May 2024 Configuration and Use Manual MS-00809-0200-1600 Table 16-7: Coils and test terminal pairs (continued) Coil Sensor model Terminal colors Lead length compensator (LLC) All except T-Series, F025, F050, F100 A or B, F300 and CMF400 (see note) Yellow to orange Composite RTD CMFS025-150 and T-Series Yellow to orange Fixed resistor (see note) CMFS007, CMFS010, CMFS015, CMF400, and F300 Yellow to orange Note The F300 and CMF400 fixed resistor applies only to certain specific F300 and CMF400 releases. Contact customer support for more information. There should be no open circuits, that is, no infinite resistance readings. The left pickoff and right pickoff readings should be the same or very close (±5 Ω). If there are any unusual readings, repeat the coil resistance tests at the sensor junction box to eliminate the possibility of faulty cable. The readings for each coil pair should match at both ends. 4. Test the terminals in the sensor junction box for shorts to case. a) Leave the terminal blocks disconnected. b) Remove the lid of the junction box. c) Testing one terminal at a time, place a DMM lead on the terminal and the other lead on the sensor case. With the DMM set to its highest range, there should be infinite resistance on each lead. If there is any resistance at all, there is a short to case. 5. Test the resistance of junction box terminal pairs. a) Test the brown terminal against all other terminals except the red one. b) Test the red terminal against all other terminals except the brown one. c) Test the green terminal against all other terminals except the white one. d) Test the white terminal against all other terminals except the green one. e) Test the blue terminal against all other terminals except the gray one. f) Test the gray terminal against all other terminals except the blue one. g) Test the orange terminal against all other terminals except the yellow and violet ones. h) Test the yellow terminal against all other terminals except the orange and violet ones. i) Test the violet terminal against all other terminals except the yellow and orange ones. There should be infinite resistance for each pair. If there is any resistance at all, there is a short between terminals. Postrequisites To return to normal operation: 1. Replace the lid on the sensor junction box. Important When reassembling the meter components, be sure to grease all O-rings. 220 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Using the transmitter display May 2024 A Using the transmitter display This section explains how to use the display. Using the display, you can move through the menus, configure the application, monitor and control the application, and perform maintenance and diagnostic tasks. A.1 Components of the transmitter display The transmitter display includes two status LEDs, a multi-line LCD panel, and four capacitive buttons — left, up, down, and right — used to access the display menus and navigate the display screens. Figure A-1: 1600 transmitter display A. Status LED B. LCD Display Status LEDs The status LEDs indicate the current state of the transmitter (STATUS). From the display, the symbol “√” on the right side is the transmitter status LED. The symbol “NET” on the left side is the network status LED. The 1600 status LED supports NE107 mode. For configuration information, see the Micro Motion 1600 Transmitters with Configurable Inputs and Outputs: Configuration and Use Manual. Configuration and Use Manual 221 Using the transmitter display May 2024 Configuration and Use Manual MS-00809-0200-1600 Table A-1: Status LED and device status Status LED condition Device status Solid green No alerts are active. Solid yellow One or more alerts are active with Alert Severity = Out of Specification, Maintenance Required, or Function Check. Solid red One or more alerts are active with Alert Severity = Failure. Flashing yellow (1 Hz) Auto zero or SMV test in progress Flashing green An auto zero is being performed. Status LED off Transmitter is not receiving power. Display is not seated or not functioning properly. LCD panel In normal operation, the LCD panel shows the current value of the display variables, and their measurement units. The LCD panel also provides access to the display menus and alert information. From the display menus, you can: • View the current configuration and make configuration changes. • Perform procedures such as loop testing and zero verification. • Run batches. The alert information allows you to see which alerts are active, acknowledge the alerts individually or as a group, and to see more detailed information for individual alerts. A.2 Access and use the display menus The display menus allow you to perform most configuration, administration, and maintenance tasks. The four switches, ⇦⇧⇩⇨, are used to navigate the menus, make selections, and enter data. Procedure 1. Observe the action bar at the bottom of the LCD panel. The action bar displays Menu⇨. 2. Hold your thumb or finger over the ⇨ membrane switch to activate it. The top-level menu is displayed. 3. Navigate the menus using the four membrane switches: • Activate ⇧ or ⇩ to scroll to the previous or next item in the menu. • Activate and hold ⇧ or ⇩ (approximately 1 second) to scroll rapidly through numbers or menu options. • Activate ⇨ to drill down to a lower menu or to select an option. • Activate and hold ⇨ to save and apply your action. • Activate ⇦ to return to the previous menu. • Activate and hold ⇦ to cancel your action. The action bar is updated with context-sensitive information. The ⇨ and ⇦ symbols indicate the associated membrane switch. 222 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Using the transmitter display May 2024 If the menu or the topic is too large for a single display screen, the ⇩ and ⇧ symbols at the bottom and top of the LCD panel are used to indicate that you must scroll down or up to see more information. Figure A-2: Navigation arrows Configuration and Use Manual 223 Using the transmitter display May 2024 Configuration and Use Manual MS-00809-0200-1600 4. If you make a menu choice that leads back to the main menu, or changes to certain procedures such as zero calibration: • If display security is not enabled, the display prompts you to activate ⇦⇩⇨, in that order. This feature protects against accidental changes to configuration, but does not provide any security. Figure A-3: Security prompts • 224 If display security is enabled, the display prompts you to enter the display password. Emerson.com Configuration and Use Manual MS-00809-0200-1600 Using the transmitter display May 2024 5. If you make a menu choice that requires entering a numeric value or character string, the display provides a screen similar to the following: Figure A-4: Numeric values and character strings • Activate ⇦ or ⇨ to position the cursor. • Activate ⇧ and ⇩ to scroll through the values that are valid for that position. • Repeat until all characters are set. • Activate and hold ⇨ to save the value. 6. To exit the display menu system, use either of the following methods: • Wait until the menu times out and returns to the display variables. • Exit each menu separately, working your way back to the top of the menu system. Configuration and Use Manual 225 Using the transmitter display May 2024 226 Configuration and Use Manual MS-00809-0200-1600 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Using ProLink III with the transmitter May 2024 B Using ProLink III with the transmitter B.1 Basic information about ProLink III ProLink III is a configuration and service tool available from Micro Motion. ProLink III runs on a Windows platform and provides complete access to transmitter functions and data. Version requirements Use the latest version of ProLink III and the device firmware to support all features. ProLink version 5.0 or later is needed to recognize 1600 transmitters. For details about ProLink III device support, refer to the ProLink III ChangeLog.txt file. ProLink III requirements To install ProLink III, you must have: • The ProLink III installation media • The ProLink III installation kit for your connection type: — Cables and connectors: USB-C to USB-A cable or USB-C to USB-A adapter To obtain ProLink III and the appropriate installation kit, contact customer support. ProLink III documentation Most of the instructions in this manual assume that you are already familiar with ProLink III or that you have a general familiarity with Windows programs. If you need more information than this manual provides, see the ProLink III with ProcessViz Software User Manual. In most ProLink III installations, the manual is installed with the ProLink III program. Additionally, the ProLink III manual is available on the documentation CD or at Emerson.com. ProLink III features and functions ProLink III offers complete transmitter configuration and operation functions. ProLink III also offers a number of additional features and functions, including: • A Professional version with expanded features not available on the Basic version • The ability to save the transmitter configuration set to a file on the PC, and reload it or propagate it to other transmitters • The ability to log specific types of data to a file on the PC • The ability to view performance trends for various types of data on the PC • The ability to connect to and view information for more than one device • A guided connection wizard These features are documented in the ProLink III with ProcessViz Software User Manual. ProLink III features are not documented in this manual. ProLink III messages As you use ProLink III with a Micro Motion transmitter, you will see a number of messages and notes. This manual does not document all of these messages and notes. Important The user is responsible for responding to messages and notes and complying with all safety messages. Configuration and Use Manual 227 Using ProLink III with the transmitter May 2024 Configuration and Use Manual MS-00809-0200-1600 B.2 Connect with ProLink III A connection from ProLink III to your transmitter allows you to read process data, configure the transmitter, and perform maintenance and troubleshooting tasks. B.2.1 ProLink III connection types There are two ways to connect a Prolink III PC to the transmitter depending on how it has been ordered: the service port or the communications protocol which is licensed for Channel A. This will be HART® over Bell 202 for Output hardware board code A or Modbus over RS-485 for output hardware board code M. B.2.2 Connect ProLink III to the transmitter WARNING If the transmitter is in a hazardous area, do not remove the housing cover while the transmitter is powered up. Failure to follow these instructions can cause an explosion, resulting in serious injury or death. Prerequisites For a service port connection, a USB-C to USB-A cable is supplied with the transmitter. For a Modbus® connection, use an RS-485 converter connected to Channel A. No other Modbus host can be used for communicating. For a HART® connection, use a Bell 202 converter connected to Channel A with a load resistor (250-600 ohms). You will need to know which comm port your converter is using. If you don't know the correct comm port, click on the Connect via guided connection wizard button. Procedure 1. Start ProLink III. 2. Choose Connect to Physical Device. 3. Select a Protocol and related settings: • For Ethernet connection: — Select Modbus TCP — Type in the IP Address of the transmitter — Leave the remaining settings at their default values 4. Select Connect. 228 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Using a field communicator with the transmitter May 2024 C Using a field communicator with the transmitter C.1 Basic information about field communicators A field communicator is a handheld configuration and management tool that can be used with a variety of devices, including Micro Motion transmitters. It provides complete access to transmitter functions and data. Field communicator documentation Most of the instructions in this manual assume that you are already familiar with field communicators and can perform the following tasks: • Turn on the field communicator • Navigate the field communicator menus • Send configuration data to the device • Use the alpha keys to enter information Field communicator menus and messages As you use a field communicator with a Micro Motion transmitter, you will see a number of messages and notes. This manual does not document all of these messages and notes. Important The user is responsible for responding to messages and notes and complying with all safety messages. C.2 Connect with a field communicator A connection from a field communicator to your transmitter allows you to read process data, configure the transmitter, and perform maintenance and troubleshooting tasks. Prerequisites The following HART® device description (DD) must be installed on the field communicator : 1600 Dev v1 DD V1 or later. WARNING If the transmitter is in a hazardous area, do not remove the housing cover while the transmitter is powered up. Failure to follow these instructions can cause an explosion, resulting in serious injury or death. Important If the HART security switch is set to ON, HART protocol cannot be used to perform any action that requires writing to the transmitter. For example, you cannot change the configuration, reset totalizers, or perform calibration using a field communicator with a HART connection. When the HART security switch is set to OFF, no functions are disabled. Procedure 1. To connect to a point in the local HART loop, attach the leads from the field communicator to any point in the loop and add resistance as necessary. The field communicator must be connected across a resistance of 250–600 Ω. Configuration and Use Manual 229 Using a field communicator with the transmitter May 2024 Configuration and Use Manual MS-00809-0200-1600 2. To connect to a point in the HART multidrop network, attach the leads from the field communicator to any point on the network. 3. Turn on the field communicator and wait until the main menu is displayed. 4. If you are connecting across a multidrop network: • Set the field communicator to poll. The device returns all valid addresses. • Enter the HART address of the transmitter. The default HART address is 0. However, in a multidrop network, the HART address has probably been set to a different, unique value. Postrequisites To navigate to the Online menu, choose HART Application → Online. Most configuration, maintenance, and troubleshooting tasks are performed from the Online menu. Tip You may see messages related to the DD or active alerts. Press the appropriate buttons to ignore the message and continue. Need help? A field communicator requires a minimum of 1 Vdc across the connection leads to communicate. If necessary, increase the resistance at the connection point until 1 Vdc is achieved. 230 Emerson.com Configuration and Use Manual MS-00809-0200-1600 Concentration measurement matrices May 2024 D Concentration measurement matrices D.1 Standard matrices for the Concentration Measurement application The standard concentration matrices available from Micro Motion are applicable for a variety of process fluids. These matrices are included in the ProLink III installation folder. Tip If the standard matrices are not appropriate for your application, you can build a custom matrix or purchase a custom matrix from Micro Motion. Matrix name Description Deg Balling Matrix represents percent extract, by g/cm3 mass, in solution, based on °Balling. For example, if a wort is 10 °Balling and the extract in solution is 100% sucrose, the extract is 10% of the total mass. °F Mass Concentration (Density) Deg Brix Matrix represents a hydrometer scale for sucrose solutions that indicates the percent by mass of sucrose in solution at a given temperature. For example, 40 kg of sucrose mixed with 60 kg of water results in a 40 °Brix solution. g/cm3 °C Mass Concentration (Density) Deg Plato Matrix represents percent extract, by mass, in solution, based on °Plato. For example, if a wort is 10 °Plato and the extract in solution is 100% sucrose, the extract is 10% of the total mass. g/cm3 °F Mass Concentration (Density) HFCS 42 Matrix represents a hydrometer scale for HFCS 42 (high-fructose corn syrup) solutions that indicates the percent by mass of HFCS in solution. g/cm3 °C Mass Concentration (Density) HFCS 55 Matrix represents a hydrometer scale for HFCS 55 (high-fructose corn syrup) solutions that indicates the percent by mass of HFCS in solution. g/cm3 °C Mass Concentration (Density) HFCS 90 Matrix represents a hydrometer scale for HFCS 90 (high-fructose corn syrup) solutions that indicates the percent by mass of HFCS in solution. g/cm3 °C Mass Concentration (Density) Configuration and Use Manual Density unit Temperature unit Derived variable 231 Concentration measurement matrices May 2024 Configuration and Use Manual MS-00809-0200-1600 D.2 Derived variables and calculated process variables The Concentration Measurement application calculates a different set of process variables from each derived variable. The process variables are then available for viewing or reporting. Calculated process variables Derived variable Description Density at Reference Mass/unit volume, corrected to a given reference temperature ✓ ✓ Specific Gravity The ratio of the density of a process fluid at a given temperature to the density of water at a given temperature The two given temperature conditions do not need to be the same. ✓ ✓ Mass Concentration (Density) The percent mass of solute or of material in suspension in the total solution, derived from reference density ✓ ✓ Mass Concentration (Specific Gravity) The percent mass of solute or of material in suspension in the total solution, derived from specific gravity ✓ ✓ Volume Concentration (Density) The percent volume of solute or of material in suspension in the total solution, derived from reference density ✓ ✓ Volume Concentration (Specific Gravity) The percent volume of solute or of material in suspension in the total solution, derived from specific gravity ✓ ✓ Concentration (Density) The mass, volume, weight, or number of moles of solute or of material in suspension in proportion to the total solution, derived from reference density ✓ ✓ Concentration (Specific Gravity) The mass, volume, weight, or number of moles of solute or of material in suspension in proportion to the total solution, derived from specific gravity ✓ ✓ 232 Density at Standard reference volume temp flow rate Specific gravity Concentration Net mass flow rate ✓ ✓ ✓ ✓ Net volume flow rate ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Emerson.com Configuration and Use Manual MS-00809-0200-1600 Environmental compliance May 2024 E Environmental compliance E.1 RoHS and WEEE In compliance with the RoHS directive (Restriction of Hazardous Substances) and the WEEE directive (Waste Electrical and Electronic Equipment), the battery in the Micro Motion 1600 Transmitter cannot be serviced or replaced by users. If the transmitter requires disposal, follow all applicable local laws. Configuration and Use Manual 233 * MS-00809-0200-1600* MS-00809-0200-1600 Rev. AA 2024 For more information: Emerson.com/global ©2024 Micro Motion, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Micro Motion, ELITE, ProLink, MVD and MVD Direct Connect marks are marks of one of the Emerson Automation Solutions family of companies. All other marks are property of their respective owners. ">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща на прост език, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или най-сложните документи.
Реклама