- Home
- Domestic appliances
- Climate control
- Split-system air conditioners
- Mitsubishi Electric
- MFZ-KA 25VA
- Operating instructions
- 11 Pages
Mitsubishi Electric MFZ-KA 25VA, 35VA, 50VA Floor-type Air Conditioner Operating Instructions
Below you will find brief information for Floor-type Air Conditioner MFZ-KA25VA, Floor-type Air Conditioner MFZ-KA35VA, Floor-type Air Conditioner MFZ-KA50VA. This document has operating instructions for various modes, fan speed and airflow direction control, timer settings, and provides information on cleaning and troubleshooting. It also includes a section on installation and safety precautions.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
FLOOR-TYPE AIR CONDITIONERS
INDOOR UNIT
MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA
JG79A126H04_cover.indd 1
OPERATING INSTRUCTIONS
For user
• To use this unit correctly and safely, be sure to read these operating instructions before use.
BEDIENUNGSANLEITUNG
For den Anwender dingt diese Bedienungsanleitung vor der Inbetriebnahme durchlesen.
NOTICE D’UTILISATION
A l’attention des clients
• Pour avoir la certitude d’utiliser cet appareil correctement et en toute sécurité, veuillez lire cette notice d’instructions avant de mettre le climatiseur sous tension.
BEDIENINGSINSTRUCTIES
Voor de klant dieningsinstructies voor gebruik eerst doorlezen.
MANUAL DE INSTRUCCIONES
estas instrucciones de funcionamiento.
Para los clientes
• Para utilizar esta unidad de forma correcta y segura, lea previamente
LIBRETTO D’ISTRUZIONI
Per gli utenti leggere il presente libretto d’istruzioni prima dell’uso.
ΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣ
Για το χρήστη
• Για να χρησιμοποιήσετε αυτή τη μονάδα σωστά και με ασφάλεια, βεβαι-
English
Deutsch
Français
Nederlands
Español
Italiano
Ελληνικά
INSTRUÇÕES DE OPERAÇÃO
Para o utilizador se de que lê estas instruções de operação antes da utilização.
BETJENINGSVEJLEDNING
og sikkert.
Til kunden
• Læs denne betjeningsvejledningen før brug, så enheden bruges korrekt
BRUKSANVISNING
och på rätt sätt.
För användaren
• Läs bruksanvisningen innan enheten tas i bruk så att den används säkert
ÇALIŞTIRMA TALİMATLARI
Kullanıcı için bu işletim talimatlarını okuduğunuzdan emin olun.
ИНСТРУКЦИИ ПО ЭКСПЛУАТАЦИИ
Для пользователя
• В целях правильной и безопасной эксплуатации данного устройс-
Português
Dansk
Svenska
Türkçe
Русский
2010/03/02 13:35:34
● OPERATING INSTRUCTIONS ●
C
ONTENTS
■
SAFETY PRECAUTIONS
■
DISPOSAL
■
NAME OF EACH PART
■
PREPARATION BEFORE OPERATION
■
SELECTING OPERATION MODES
■
FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT
■
AIR OUTLET SELECTION
■ i-save
OPERATION
■
ECONO COOL OPERATION
■
TIMER OPERATION (ON/OFF TIMER)
■
CLEANING
■
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
■
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME
■
INSTALLATION PLACE AND ELECTRICAL WORK
■
SPECIFICATIONS
S
AFETY PRECAUTIONS
• Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these “Safety Precautions” before use.
• Since the cautionary items shown here are important for safety, be sure to observe them.
• After reading this manual, keep it together with the installation manual in a handy place for easy reference.
• Be sure to receive a guarantee card from your dealer and check that the purchased date and shop name, etc. are entered correctly.
Marks and their meanings
WARNING :
CAUTION :
Incorrect handling could cause serious hazard, such as death, serious injury, etc. with a high probability.
Incorrect handling could cause serious hazard depending on the conditions.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your fi nger or stick, etc.
: Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
9
9
9
7
8
6
6
5
6
4
5
3
3
1
2
WARNING
Do not connect the power cord to an intermediate point, use an extension cord, or connect multiple devices to a single AC outlet.
• This may cause overheating, fi re, or electric shock.
Make sure the power plug is free of dirt and insert it securely into the outlet.
• A dirty plug may cause fi re or electric shock.
Do not bundle, pull, damage, or modify the power cord, and do not apply heat or place heavy objects on it.
• This may cause fi re or electric shock.
Do not turn the breaker OFF/ON or disconnect/connect the power plug during operation.
• This may create sparks, which can cause fi re.
• After the indoor unit is switched OFF at the remote controller, make sure to turn the breaker OFF or disconnect the power plug.
Do not expose your body directly to cool air for a prolonged length of time.
• This could be detrimental to your health.
The unit should not be installed, relocated, disassembled, altered, or repaired by the user.
• An improperly handled air conditioner may cause fi re, electric shock, injury, or water leakage.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not insert your fi nger, a stick, or other objects into the air inlet or outlet.
• This may cause injury, since the fan inside rotates at high speeds during operation.
In case of an abnormal condition (such as a burning smell), stop the air conditioner and disconnect the power plug or turn the breaker OFF.
• A continued operation in the abnormal state may cause a malfunction, fi re, or electric shock. In this case, consult your dealer.
When the air conditioner does not cool or heat, there is a possibility of refrigerant leakage. In this case, consult your dealer. If a repair involves recharging the unit with refrigerant, ask the service technician for details.
• The refrigerant used in the air conditioner is safe. Normally, it does not leak. However, if refrigerant leaks and comes in contact with a heat source such as a fan heater, kerosene heater, or cooking stove, it will create a harmful gas.
CAUTION
Do not touch the air inlet or the aluminum fi ns of the indoor/outdoor unit.
• This may cause injury.
Do not use insecticides or fl ammable sprays on the unit.
• This may cause a fi re or deformation of the unit.
Do not expose pets or houseplants to direct airfl ow.
• This may cause injury to the pets or plants.
Do not place other electric appliances or furniture under the indoor/outdoor unit.
• Water may drip down from the unit, which may cause damage or malfunction.
Do not leave the unit on a damaged installation stand.
• The unit may fall and cause injury.
En-1
JG79A126H04_en.indd 1 2010/03/17 8:35:43
S
AFETY PRECAUTIONS
CAUTION
Do not step on an unstable bench to operate or clean the unit.
• This may cause injury if you fall down.
Do not pull on the power cord.
• This may cause a portion of the core wire to break, which may cause overheating or fi re.
Do not charge or disassemble the batteries, and do not throw them into a fi re.
• This may cause the batteries to leak, or cause a fi re or explosion.
Do not operate the unit for a long time at high humidity (80%
RH or more), such as with a door or window left open.
• The water condensation in the air conditioner may drip down, wetting or damaging the furniture.
Do not use the unit for special purposes, such as storing food, raising animals, growing plants, or preserving precision devices or art objects.
• This may cause deterioration of quality, or harm to animals and plants.
Do not expose combustion appliances to direct airfl ow.
• This may cause incomplete combustion.
Before cleaning the unit, switch it OFF and disconnect the power plug or turn the breaker OFF.
• This may cause injury, since the fan inside is rotating at high speeds during operation.
When the unit will be unused for a long time, disconnect the power plug or turn the breaker OFF.
• The unit may accumulate dirt, which may cause overheating or fi re.
Replace all batteries of the remote controller with new ones of the same type.
• Using an old battery together with a new one may cause overheating, leakage, or explosion.
If the battery fl uid comes in contact with your skin or clothes, wash them thoroughly with clean water.
• If the battery fl uid comes in contact with your eyes, wash them thoroughly with clean water and immediately seek medical attention.
Ensure that the area is well-ventilated when the unit is operated together with a combustion appliance.
• Inadequate ventilation may cause oxygen starvation.
Turn the breaker OFF when you hear thunder and there is a possibility of a lightning strike.
• The unit may be damaged if lightning strikes.
After the air conditioner is used for several seasons, perform inspection and maintenance in addition to normal cleaning.
• Dirt or dust in the unit may create an unpleasant odor, contribute to growth of fungi, such as mold, or clog the drain passage, and cause water to leak from the indoor unit. Consult your dealer for inspection and maintenance, which require specialized knowledge and skills.
D
ISPOSAL
To dispose of this product, consult your dealer.
Note:
This symbol mark is for EU countries only.
This symbol mark is according to the directive 2002/96/
EC Article 10 Information for users and Annex IV, and/ or to the directive 2006/66/EC Article 20 Information for end-users and Annex II.
Fig. 1
Do not operate switches with wet hands.
• This may cause electric shock.
Do not clean the air conditioner with water or place an object that contains water, such as a fl ower vase, on it.
• This may cause fi re or electric shock.
Do not step on or place any object on the outdoor unit.
• This may cause injury if you or the object falls down.
For installation
WARNING
Consult your dealer for installing the air conditioner.
• It should not be installed by the user since installation requires specialized knowledge and skills. An improperly installed air conditioner may cause water leakage, fi re, or electric shock.
Provide a dedicated power supply for the air conditioner.
• A non-dedicated power supply may cause overheating or fi re.
Do not install the unit where fl ammable gas could leak.
• If gas leaks and accumulates around the outdoor unit, it may cause an explosion.
Earth the unit correctly.
• Do not connect the earth wire to a gas pipe, water pipe, lightning rod, or a telephone ground wire. Improper earthing may cause electric shock.
CAUTION
Install an earth leakage breaker depending on the installation location of the air conditioner (such as highly humid areas).
• If an earth leakage breaker is not installed, it may cause electric shock.
Ensure that the drain water is properly drained.
• If the drain passage is improper, water may drip down from the indoor/outdoor unit, wetting and damaging the furniture.
In case of an abnormal condition
Immediately stop operating the air conditioner and consult your dealer.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused.
This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.
If a chemical symbol is printed beneath the symbol (Fig. 1), this chemical symbol means that the battery or accumulator contains a heavy metal at a certain concentration. This will be indicated as follows:
Hg: mercury (0,0005%), Cd: cadmium (0,002%), Pb: lead (0,004%)
In the European Union there are separate collection systems for used electrical and electronic products, batteries and accumulators.
Please, dispose of this equipment, batteries and accumulators correctly at your local community waste collection/recycling centre.
Please, help us to conserve the environment we live in!
En-2
JG79A126H04_en.indd 2 2010/03/17 8:35:48
● OPERATING INSTRUCTIONS ●
N
AME OF EACH PART
Indoor unit
Vertical vane
Air outlet
Horizontal vane
Front grille
Fan guard
Remote controller
Signal transmitting section
Distance of signal :
About 6 m
Beep(s) will be heard from the indoor unit when the signal is received.
Operation display section
Catechin air fi lter
Air cleaning fi lter (Anti-
AllergyEnzyme Filter, blue bellows type)
Damper
Air outlet
Vertical vane
Air inlet
Display and operation section
(When the front grille is opened)
Operation indicator lamp
Emergency operation switch
Air outlet selection switch
Remote control receiving section
ON/OFF
(operate/stop) button
Operation select button
Page 4
FAN speed control button
Page 5
ECONO COOL button
Page 6
VANE control button
Page 5
Temperature buttons
Page 4
Off-timer button
Page 6
On-timer button
Page 6 i-save button
Page 6
TIME set buttons
Page 3, 6
Increase time
Decrease time
CLOCK set button
Page 3
RESET button
Page 3
Lid
Slide down to open
Remote controller holder
Outdoor unit
Air inlet
(back and side)
Air outlet
Piping
• Install the remote controller holder in a place where the signal can be received by the indoor unit.
Only use the remote controller provided with the unit.
Do not use other remote controllers.
Drainage hose Drain outlet
Outdoor units may be different in appearance.
P
REPARATION BEFORE OPERATION
Before operation:
Insert the power supply plug into the power outlet and/or turn the breaker on.
Installing the remote controller batteries
1.
Remove the front lid
Setting current time
1.
2.
Press RESET
Press CLOCK
2.
Insert AAA alkaline batteries
3.
Install the front lid
• Make sure the polarity of the batteries is correct.
• Do not use manganese batteries. The remote controller could malfunction.
• Do not use rechargeable batteries.
• Replace all batteries with new ones of the same type.
• Batteries can be used for approximately 1 year. However, batteries with expired shelf lives last shorter.
En-3
4.
Press CLOCK again
3.
Press TIME buttons to set time
Each press increases/ decreases time by 1 minute (10 minutes when pressed longer).
• Press RESET and CLOCK gently using a thin stick.
If the RESET button is not pressed, the remote controller may not operate correctly.
JG79A126H04_en.indd 3 2010/03/17 8:35:58
S
ELECTING OPERATION MODES
AUTO mode (Auto changeover)
The unit selects the operation mode according to the difference between the room temperature and the set temperature. During AUTO mode, the unit changes mode (COOL↔HEAT) when the room temperature is 2°C away from the set temperature for more than 15 minutes.
Note:
During multi system operation, the unit may not be able to switch operation mode between COOL and HEAT. In this case, the indoor unit becomes standby mode.
COOL mode
Enjoy cool air at your desired temperature.
Do not operate COOL mode at low outside temperature (less than -10°C)
Water condensed in the unit may drip and wet or damage furniture, etc.
DRY mode
Dehumidify your room. The room may be cooled slightly.
Temperature cannot be set during DRY mode.
HEAT mode
Enjoy warm air at your desired temperature.
1
Press to start the operation.
2
Press to select operation mode.
Each press changes mode in the following order:
(AUTO)
(COOL)
(DRY)
(HEAT)
3
Press or to set the temperature.
Each press raises or lowers the temperature by 1°C.
Press to stop the operation.
• The same setting is selected the next time by simply pressing .
Operation indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
Operation Indicator
(Green) : Lighted
(Orange) : Lighted
(Green) : Blinking
(Orange) : Blinking
: Not lighted
Indication
[Normal operation]
[i-save operation]
Operation state
This shows that the air conditioner is operating to reach the target temperature.
Please wait until the target temperature is obtained.
This shows that the room temperature is approaching the target temperature.
Difference between target temperature and room temperature
About 2°C or more
About 2°C or less
This shows a state of standby for operation. Please refer to Information for multi system air conditioner above.
—
Refer to the description of i-save mode.
—
Emergency operation
When the remote controller cannot be used...
Emergency operation can be activated by pressing the emergency operation switch on the indoor unit.
Each time the emergency operation switch is pressed, the operation will change in the following order:
Operation indicator lamp
Emergency COOL
Emergency HEAT
Set temperature : 24°C
Fan speed : Medium
Horizontal vane : Auto
Stop
Note:
The fi rst 30 minutes of operation is test run. Temperature control does not work, and fan speed is set to High.
Auto restart function
If a power failure occurs or the main power is turned off during operation, “Auto restart function” automatically starts operation in the same mode as the one set
with the remote controller
just before the shutoff of the main power. When timer is set, timer setting is cancelled and the unit starts operation when power is resumed.
If you do not want to use this function, please consult the service representative because the setting of the unit needs to be changed.
Multi system operation
Two or more indoor units can be operated by one outdoor unit. When several indoor units are operated simultaneously, cooling and heating operations cannot be done at the same time. When COOL is selected with one unit and HEAT with another or vice versa, the unit operated later becomes standby mode.
En-4
JG79A126H04_en.indd 4 2010/03/17 8:36:05
● OPERATING INSTRUCTIONS ●
F
AN SPEED AND
AIRFLOW DIRECTION ADJUSTMENT
A
IR OUTLET SELECTION
Press to select fan speed. Each press will change fan speed in the following order:
(AUTO) (Low) (Med.) (High) (Super High)
• Two short beeps will be heard from the indoor unit when set to AUTO.
Press to select vertical airfl ow direction. Each press will change airfl ow direction in the following order:
(AUTO) (1) (2) (3) (4) (5) (SWING)
• Two short beeps will be heard from the indoor unit when set to AUTO.
• Moving the horizontal vane manually can cause trouble.
• The horizontal vane automatically moves in certain intervals to determine its position, and then it returns to the set position.
Airflow direction
(AUTO) .......The vane will be set to the most effi cient airfl ow direction.
COOL/DRY : position (1)
HEAT (upper and lower air outlets) : position (3)
HEAT (upper air outlet only) : position (5)
(Manual) .....For efficient air conditioning, select upper position for COOL/
DRY, and lower position for HEAT. During COOL/DRY, when the vane is set to position (3), (4), or (5), the vane automatically moves to position (1) after 0.5 to 1 hour to prevent water dripping.
(Swing) .......The vane will move up and down intermittently.
■
To change the horizontal airfl ow direction.
Move the vertical vane manually before starting operation.
Select to blow air from the upper and lower air outlets.
Air will blow only from the upper outlet in the following conditions:
• During COOL: When the room temperature is close to set temperature. When the air conditioner has operated for 1 hour.
• During DRY operation.
• During HEAT: When the air flow temperature is low.
(During defrosting operation, start of operation, etc.)
Select to blow air from the upper air outlet only.
Note:
Be sure to keep the area around the damper of the lower air outlet free of any objects. If any objects block the normal operation of the damper, the left operation indicator lamp may blink.
Set the air outlet selection switch to the end. Otherwise, air outlet cannot be selected as intended.
Always adjust the vane when the damper is open. Opening the damper forcibly with hands can cause damage or malfunction.
En-5
JG79A126H04_en.indd 5 2010/03/17 8:36:10
i
-save OPERATION
E
CONO COOL OPERATION
1
Press to select i-save mode. Select i-save during
COOL, ECONO COOL, or HEAT operation.
• The operation indicator lamp on the right side of the indoor unit lights in orange.
2
Set the temperature, fan speed, and air fl ow direction.
• The same setting will be selected from the next time by simply pressing
.
• Two groups of setting can be saved. (one for COOL/ECONO COOL, one for HEAT)
Press again to cancel i-save operation.
• Pressing will also cancel i-save operation.
• The operation indicator lamp on the right side of the indoor unit turns off or changes from orange to green.
i-save operation
A simplifi ed set back function enables to recall the preferred (preset) setting with a single push of the button. Press the button again and you can go back to the previous setting in an instance.
Example of use:
1. Low energy mode
Set the temperature 2 to 3ºC warmer in COOL and cooler in HEAT mode.
This setting is suitable for unoccupied room, and while you are sleeping.
2. Saving frequently used settings
Save your preferred setting for COOL/ECONO COOL and HEAT. This enables you to select your preferred setting with a single push of the button.
Press during COOL mode
page 4 to start
ECONO COOL operation.
The unit performs swing operation vertically in various cycle according to the temperature of the unit. Set temperature is set 2°C higher automatically.
Press again to cancel ECONO COOL operation.
• Pressing also cancels ECONO COOL operation.
What is “ECONO COOL”?
Swing air fl ow (change of air fl ow) makes you feel cooler than constant air fl ow. So, even though the set temperature is automatically set 2°C higher, it is possible to perform cooling operation with keeping comfort. As a result, energy can be saved.
1
T
IMER OPERATION (ON/OFF TIMER)
Press
or
during operation to set the timer.
(ON timer) : The unit turns ON at the set time.
(OFF timer) : The unit turns OFF at the set time.
* or blinks.
* Make sure that the current time is set correctly.
Page 3
2
Press (Increase) and time of timer.
(Decrease) to set the
Each press increases or decreases the set time by 10 minutes.
3
Press
Note:
or again to cancel timer.
• ON and OFF timers can be used in combination. mark indicates the order of timer operations.
• If power failure occurs while ON/OFF timer is set, see
page 4
“Auto restart function”.
En-6
JG79A126H04_en.indd 6 2010/03/17 8:36:17
● OPERATING INSTRUCTIONS ●
C
LEANING
Instructions:
• Switch off the power supply or turn off the breaker before cleaning.
• Be careful not to touch the metal parts with your hands.
• Do not use benzine, thinner, polishing powder, or insecticide.
Front grille
1. Push the 2 positions indicated by the arrows until a click is heard, and open the front grille.
2. Unhook the string which holds the grille.
3. Open the grille completely and then remove it.
• Wipe with a soft dry cloth or wash it with water.
• Do not soak it in water for more than two hours.
• Dry it well in shade before installing it.
4. Install the grille by following the removal procedure in reverse. Be sure to hook the string before closing the grille.
• Use only diluted mild detergents.
• Do not expose parts to direct sunlight, heat, or fl ames to dry.
• Do not water hotter than 50°C.
Heat exchanger
• Wear gloves to protect your hands.
• Use the QUICK CLEAN KIT
(optional).
Parts Number MAC-093SS-E
• Refer to the instructions described in the QUICK CLEAN
KIT for details.
Note:
• Clean the fi lters regularly for best performance and to reduce power consumption.
• Please consult your dealer for seasonal inspection.
Air cleaning fi lter
•
Clean every 3 months.
• Soak the fi lter together with its frame in lukewarm water and wash it.
• After cleaning, dry it well in shade and put it back to its original position.
Install all tabs of the air fi lter.
• Replace it with a new air cleaning fi lter every year for best performance.
• Parts Number MAC-415FT-E
Air fi lter (Catechin air fi lter)
•
Clean every 2 weeks
• Remove dirt by a vacuum cleaner, or wash with water.
• Dry it well in shade before installing it.
What is “Catechin air fi lter” ?
The air fi lter is dyed with a natural material, catechin, that is contained in tea. The catechin air fi lter deodorizes odor and noxious gases such as formaldehyde, ammonia, and acetaldehyde. Moreover, it restraints the activity of the viruses adhering to the fi lter.
En-7
JG79A126H04_en.indd 7 2010/03/17 8:36:22
W
HEN YOU THINK THAT TROUBLE HAS OCCURRED
Even if these items are checked, when the unit does not recover from the trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated.
• Is the breaker turned on?
• Is the power supply plug connected?
• Is the ON timer set?
• Is there anything that block the normal operation of the damper? Page 5
The unit cannot be operated for about 3 minutes when restarted.
• This protects the unit according to instructions from the microprocessor. Please wait.
Mist is discharged from the air outlet of the indoor unit.
• The cool air from the unit rapidly cools moisture in the air inside the room, and it turns into mist.
The swing operation of the
HORIZONTAL VANE is suspended for a while, then restarted.
The air fl ow direction changes during operation.
The direction of the horizontal vane cannot be adjusted with the remote controller.
The operation is stopped for about 10 minutes in the heating operation.
The unit starts operation by itself when the main power is turned on, though it isn’t operated with the remote controller.
The damper opens and closes automatically.
• This is for the swing operation of the HORI-
ZONTAL VANE to be performed normally.
• In the heating operation, if the air fl ow temperature is too low or when defrosting is being done, the horizontal vane is automatically set to vertical position.
• When the air conditioner is operated in
COOL or DRY mode, if the operation continues with air blowing down for 1 hour, the direction of the air fl ow is automatically set to position (1) to prevent condensed water from dropping.
• The horizontal vane automatically moves in certain intervals to determine its position, and then it returns to the set position.
• Defrosting of the outdoor unit is being done.
Since this is completed in max.10 minutes, please wait. (When the outside temperature is too low and humidity is too high, frost is formed.)
• These models are equipped with an auto restart function. When the main power is turned off without stopping the unit with the remote controller and is turned on again, the unit starts operation automatically in the same mode as the one set with the remote controller just before the shutoff of the main power.
Refer to “Auto restart function”
page 4
.
• The damper is automatically controlled by a microcomputer according to the air fl ow temperature and operation time of the air conditioner.
Multi system
The indoor unit which is not operating becomes warm and a sound, similar to water fl owing, is heard from the unit.
When heating operation is selected, operation does not start right away.
• A small amount of refrigerant continues to fl ow into the indoor unit even though it is not operating.
• When operation is started during defrosting of outdoor unit is done, it takes a few minutes
(max. 10 minutes) to blow out warm air.
Outdoor Unit
The fan of the outdoor unit does not rotate even though the compressor is running.
Even if the fan starts to rotate, it stops soon.
Water leaks from the outdoor unit.
• When the outside temperature is low during cooling operation, the fan operates intermittently to maintain suffi cient cooling capacity.
• During COOL and DRY operations, pipe or pipe connecting sections are cooled and this causes water to condense.
• In the heating operation, water condensed on the heat exchanger drips down.
• In the heating operation, the defrosting operation makes water frozen on the outdoor unit melt and drip down.
Symptom
White smoke is discharged from the outdoor unit.
Explanation & Check points
• In the heating operation, vapor generated by the defrosting operation looks like white smoke.
Remote controller
The display on the remote controller does not appear or it is dim. The indoor unit does not respond to the remote control signal.
• Are the batteries exhausted? Page 3
• Is the polarity (+, -) of the batteries correct?
Page 3
• Are any buttons on the remote controller of other electric appliances being pressed?
Does not cool or heat
The room cannot be cooled or heated suffi ciently.
The room cannot be cooled suffi ciently.
The room cannot be heated suffi ciently.
Air does not blow out soon in the heating operation.
Airfl ow
The air from the indoor unit smells strange.
• Is the temperature setting appropriate?
Page 4
•
Is the fan setting appropriate? Please change fan speed to higher setting. Page 5
•
Is the air outlet selection switch set to upper air outlet only? Change to upper and lower air outlets. Page 5
•
Is the fi lter clean? Page 7
•
Is the fan or heat exchanger of the indoor unit clean? Page 7
•
Are there any obstacles blocking the air inlet or outlet of the indoor or outdoor unit?
•
Is a window or door open?
•
When a ventilation fan or a gas cooker is used in a room, the cooling load increases, resulting in an insuffi cient cooling effect.
• When the outside temperature is high, the cooling effect may not be suffi cient.
•
When the outside temperature is low, the heating effect may not be suffi cient.
•
Please wait as the unit is preparing to blow out warm air.
•
•
Is the fi lter clean? Page 7
Is the fan or heat exchanger of the indoor unit clean? Page 7
•
The unit may suck in an odor adhering to the wall, carpet, furniture, cloth, etc. and blow it out with the air.
Sound
Cracking sound is heard.
The sound as burbling is heard.
Mechanical sound is heard from the indoor unit.
The sound of water fl owing is heard.
Hissing sound is sometimes heard.
• This sound is generated by the expansion/ contraction of the intake grille, etc. due to change in temperature.
• This sound is heard when the outside air is absorbed from the drain hose by turning on the range hood or the ventilation fan, making water fl owing in the drain hose to spout out.
This sound is also heard when the outside air blows into the drain hose in case the outside wind is strong.
• This is the switching sound in turning on/off the fan or the compressor.
• This is the sound of refrigerant or condensed water fl owing in the unit.
• This is the sound when the fl ow of refrigerant inside the unit is switched.
In the following cases, stop using the air conditioner and consult your dealer.
• When water leaks or drips from the indoor unit.
• When the upper operation indicator lamp blinks.
• When the breaker trips frequently.
• The remote control signal is not received in a room where an electronic ON/OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
• Operation of the air conditioner interferes with radio or TV reception. An amplifi er may be required for the affected device.
• When an abnormal sound is heard.
En-8
JG79A126H04_en.indd 8 2010/03/17 8:36:24
● OPERATING INSTRUCTIONS ●
W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Set to the highest temperature in manual COOL mode, and operate for 3 to 4 hours. Page 4
This dries the inside of the unit.
2
Press to stop the operation.
3
Turn off the breaker and/or disconnect the power supply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter. Page 7
2
Check that the air inlet and outlet of the indoor and outdoor units are not blocked.
3
Check that the earth is connected correctly.
I
NSTALLATION PLACE AND
ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as a hot spring.
• Where oil is splashed or where the area is fi lled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the house next door.
To prevent the effects of a fl uorescent lamp, keep as far apart as possible.
Cordless phone or Portable phone
Inverter-type fl uorescent lamp
The installation location of the outdoor unit should be at least 3 m away from the antennas for TV sets, radios, etc. In areas where the reception is weak, provide greater space between the outdoor unit and the antenna of the affected device if operation of the air conditioner interferes with radio or TV reception.
wall, etc.
Keep a space to prevent the picture distortion or the noise.
Well- ventilated dry place
1 m or more 1 m or more
TV
Radio 3 m or more
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
S
PECIFICATIONS
Model
Set name
Indoor
Outdoor
Function
Power supply
Capacity
Input
Weight
Indoor
Outdoor
Refrigerant fi lling capacity (R410A)
IP code
Permissible excessive operating pressure
Noise level
Indoor
Outdoor
LP ps
HP ps
Indoor (Super High/
High/Med./Low)
Outdoor
Guaranteed operating range
kW kW kg kg kg
MPa
MPa dB(A) dB(A)
MFZ-KA25VA(H)
MFZ-KA25VA
SUZ-KA25VA2/VAH
Cooling Heating
2.5
0.58
37/32/27/22
30
0.80
46
3.4
0.835
37/32/27/22 38/33/28/23
Model
Cooling
Heating
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
32°C DB
23°C WB
21°C DB
15°C WB
27°C DB
—
20°C DB
—
SUZ-KA25/35VA2
46°C DB
—
-10°C DB
—
24°C DB
18°C WB
-10°C DB
-11°C WB
Outdoor
SUZ-KA50VA2 SUZ-KA25/35VAH
43°C DB 46°C DB
—
-10°C DB
—
24°C DB
18°C WB
-10°C DB
-11°C WB
—
-10°C DB
—
24°C DB
18°C WB
-20°C DB
-21°C WB
Note:
Rating condition
Cooling —
Heating —
Indoor: 27°C DB, 19°C WB
Indoor: 20°C DB
Outdoor: 35°C DB
Outdoor: 7°C DB, 6°C WB
As for the specifi cations of multi system, please confi rm your dealer and/or refer to the catalogue.
MFZ-KA35VA(H)
MFZ-KA35VA
SUZ-KA35VA2/VAH
Cooling Heating
~ /N, 230 V, 50 Hz
3.5
1.09
4.0
1.10
14
33
1.05
IP 20
IP 24
1.64
4.15
47
38/33/28/25
48
En-9
MFZ-KA50VA
MFZ-KA50VA
SUZ-KA50VA2
Cooling Heating
4.8
1.55
6.0
1.86
53
1.60
43/39/35/32
53
44/39/35/32
55
JG79A126H04_en.indd 9 2010/03/17 8:36:26
JG79A126H04_cover.indd 4
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
JG79A126H04
2010/03/02 13:35:34
advertisement
Key Features
- AUTO mode
- COOL mode
- DRY mode
- HEAT mode
- i-save operation
- ECONO COOL operation
- Timer operation
- Airflow direction adjustment
- Air outlet selection