Koganei 030 Solenoid valve Instruction manual
Koganei 030 is a series of solenoid valves designed for use in pneumatic systems. They come in both 2/3-port and 5-port configurations, and offer a range of features including manual override, LED indicators, and surge suppression. The valves are compatible with various wiring types, including plug connectors, DIN connectors, and built-in interface units. Koganei 030 valves are ideal for applications such as industrial automation, robotics, and packaging.
PDF
Download
Document
Advertisement
Advertisement
BK-UV002 Ver.1.0 Air Valve SOLENOID VALVES 030 SERIES INSTRUCTION MANUAL Ver.1.0 Handling Instructions and Precautions Solenoid Plug connector Internal circuit Attaching and removing plug connector ●DC12V, DC24V Standard solenoid (Surge suppression) Short circuit protection diode w(+) Lead wire: DC12V: Brown DC24V: Red Flywheel diode e(−) Lead wire: Black Solenoid Use fingers to insert the connector into the pin, push it in until the lever claw latches onto the protruded section of the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the protruded section of the connector housing, and pull it out. 1. Pre-wired common terminal at DC positive side or AC. Order code With straight connector: -CPSL With L connector: -CPLL (−)(−)(−)(−)(−)(−) Connector Connector housing Color of COM, crossover wire: DC12V :Brown DC24V :Red AC100V:Yellow Polarity is for DC. AC200V:White Pin Connector housing Lever Solenoid with LED indicator (Surge suppression) Order code: -PSL, -PLL Connector assembly LED indicator (Light Emitting Diode) Indication of polarity (DC) (+) Lead wire: DC12V: Brown DC24V: Red Connector Contact 2. Pre-wired common terminal at DC negative side Order code With straight connector: -CMSL With L connector: -CMLL (+)(+)(+)(+)(+)(+) (−) Lead wire: Black COM(+) Crossover wire Protruded section w and e are for with DIN connector (order code: -39). COM(−) C LED indicator: Red ※Illustration shows the 110 series. Crimping of connecting lead wire and contact ●AC100V, AC200V Standard solenoid (Surge suppression) w or e Solenoid Varistor e or w Lead wire: AC100V: Yellow AC200V: White To crimp lead wires into contacts, strip off 4mm [0.16in.] of the insulation from the end of the lead wire, insert it into the contact, and crimp it. Be sure at this time to avoid catching the insulation on the exposed wire crimping section. Exposed wire 4mm Contact Lead wire Equivalent to AWG22〜26 w and e are for with DIN connector (order code: -39). Hook Solenoid with LED indicator (Surge suppression) Order code: -PSL, -PLL LED indicator (Light Emitting Diode) Lead wire: AC100V: Yellow AC200V: White Common terminal pre-wired plug connector Diode LED indicator: AC100V: Yellow AC200V: Green Cautions: 1. Do not apply megger between the lead wires. 2. The DC solenoid will not short circuit even if the wrong polarity is applied, but the valve will not operate. 3. Leakage current inside the circuit could result in failure of the solenoid valve to return, or in other erratic operation. Always use it within the range of the allowable leakage current. If circuit conditions, etc. cause the leakage current to exceed the allowable leakage current, consult us. Insulation crimp tab Insulation(Maximum outer Exposed wire crimping diameterφ1.7) section Cautions: 1. Do not pull hard on the lead wire. 2. Always use a dedicated tool for crimping of connecting lead wire and contact. Contact: Model 702062-2M Manufactured by Sumiko Tech, Inc. Crimping tool: Model F1-702062 Manufactured by Sumiko Tech, Inc. Attaching and removing contact and connector Insert the contact with a lead wire into a plug connector □ hole until the contact hook latches on and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove it, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook, and then pull out the lead wire. Cautions: 1. Do not pull hard on the lead wire. It could result in defective contacts, breaking wires, etc. 2. If the pin is bent, use a small screwdriver, etc. to gently straighten out the pin, and then complete the connection to the plug connector. Crossover wire Connector Connector housing Color of COM, crossover wire: DC12V:Black DC24V:Black Cautions: 1. The diagrams show the straight connector configuration. While the connector’s orientation is different in the case of the L connector, in every case the first COM lead wire comes from the last station’s mounted valve. 2. Since the COM terminal is connected to a crossover terminal inside the connector housing, the connector cannot be switched between a positive common and a negative common by changing the connectors. Manual override Non-locking type Mounting base 030-21 To operate the manual override, press it all the way down. The valve works the same as when in the energized state as long as the manual override is pushed down, and returns to the rest position upon release. When installing a mounting base to the valve, always use the provided screws. The recommended tightening torque for the screws is 49N・cm {5kgf・cm} [4.3in・lbf]. Mounting valves on manifold When mounting valves on manifold, apply the recommended tightening torque of 39.2N・cm {4kgf・cm} [3.5in・lbf] for the valve mounting screws. PU SH ※Illustration shows the 110 series. Locking protruding type Use a small screwdriver to turn the adjusting knob several times in the clockwise direction, and lock the manual override in place. When locked, turning the adjusting knob several times in the counterclockwise direction releases a spring on the manual override, returns it to the original position, and releases the lock. For the locking protruding type, when the adjusting knob is not turned, this type acts just like the non-locking type, the valve is energized as long as the manual override is pushed down, and it returns to the rest position upon release. PU SH ※Illustration shows the 110 series. Cautions: 1. In the pilot type solenoid valve, the manual override cannot switch the main valve without air supplied from the 1(P) port. 2. Always release the lock of the locking protruding type manual overrides before commencing normal operation. 3. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. 4. Do not turn the adjusting knob more than needed. It could result in defective operation. Made to Order The 030 series Solenoid Valves include a variety of made to order solenoids for application in a broader range of control and wiring types. Plug connector Straight connector with LED indicator DIN connector L connector with LED indicator -39 -PSLN ● Without lead wire ● Connector and contacts included -PLLN ● Without lead wire ● Connector and contacts included ●When ordering, enter -PSLN or -PSLL in place of the normal option code for the wiring type. A compact connector that is highly resistant to dust and water splashes. Employs a self-stripping method that eliminates the need for de-sheathing the lead wire. ● When ordering, enter -39 in place of the normal option code for the wiring type. ● A varistor for surge suppression is also equipped. (For the AC100V and AC200V only. For the DC12V and DC24V, a flywheel diode for surge suppression is installed as standard equipment.) ● LED indicator is not available. Lead wire length Wiring instructions -1L -3L ● For plug connector ● Length -1L:1000 [39] mm [in.] -3L:3000 [118] ●For lead wire length, -1L is 1000mm [39in.] and -3L is 3000mm [118in.]. When ordering, enter -1L or -3L following the wiring type option code. ●Solenoid with DIN connector When de-sheathing (only the outer sheath of the cabtyre), pay attention to the lead wire direction. The cover will be easily mounted when the lead wire on the outer side of the terminal cover is set about 8mm longer than the inner side. Without stripping off the sheath, insert the lead wire until it contacts the lead wire stopper on the terminal body, and then place the contact from the upper side. Then use pliers to press the lead wire further to ensure that the contacts are firmly touching the core wire. JIS C3306 VCTF Conductor: 0.75mm2 [1.16×10–3 in.2] Finished: outside 6.6 (2 leads) 7.0 (3 leads) Cable 1 2 + 3 _ Cable gland Solenoid terminal arrangement Cable gasket Washer Contact Lead wire stopper Lead wire Gasket Cover mounting screw Terminal cover Lead wire Gasket Terminal body Terminal body Pliers The appropriate tightening torque for the cover mounting screw is 29.4N・cm {3kgf・cm} [2.6in・lbf]. LED indicator The LED indicator for confirmation of operation is also available without a plug connector. This creates a clean monoblock look with a compact cover. -L ● When ordering, enter -L in place of the normal option code for the wiring type. ● A varistor for surge suppression is also equipped. (For the AC100V and AC200V only. For the DC12V and DC24V, a flywheel diode for surge suppression is installed as standard equipment.) Built-in interface unit -FA Includes an interface unit with photo transistor. Can be directly controlled by a microcomputer and logic chip, and is equipped with full electric noise countermeasures and LED indicators. Electrical Specifications for Solenoid Valve with Built-in Interface Unit Item Input side ● When ordering, enter -FA in place of the normal option code for the wiring type. ● Cannot be ordered in combination with any other solenoid option. ● Rated voltages for the solenoid are AC100V and AC200V only. DC V 5 Voltage range DC V 4〜6 Current (when 5V DC is applied) mA Operating voltage DC V Return voltage DC V Lead wire: Red + Solenoid Zero cross circuit Lead wire: Black ー <Solenoid side> LED Condenser varistor Rated voltage AC V 90〜125 (100 +25 −10 %) 180〜250 (200 +25 −10 %) Hz 50 60 50 60 Starting mA (r.m.s.) 36 32 18 16 24 20 12 10 Frequency Current Solenoid side ( when rated voltage is applied 200 Shading type ) Energizing mA (r.m.s.) Leakage Frequency Hz current Current mA (r.m.s.) 50 60 50 60 0.3 0.4 0.6 0.8 Surge suppression (as standard) Built-in varistor at solenoid side Color of lead wire Yellow White Color of LED indicator (as standard) Yellow Green Dielectric voltage Insulation resistance Zero-cross function Wiring type and lead wire length Min. AC1500V on input side and solenoid side Between input side and Over 100 MΩ solenoid side, and between whole terminals and body Available Grommet type: 300mm [11.8in.] Wiring instructions Example of control circuits 1. Control by transistor 100 Type Lead wire color: AC100V: Yellow AC200V: White The interface unit is a triac with photo coupler. Applying DC5V to the input terminals when AC power is applied on the solenoid side causes the LED inside the unit to light up, turns on the triac, and energizes the solenoid. At this time, a LED indicator turns on. When the input side voltage reaches 0V, the LED inside the unit shuts off, the triac is turned off, and the solenoid is de-energized. At this time, the LED indicator is turned off. With a built-in zero-cross circuit, the zero-cross voltage is used to turn the power on, and the zero-cross current to turn it off. 0.8 or over Red (+), Black (−) Operating voltage range AC V Interface unit 18 4 or below Color of lead wire Block diagram <Input side> Specifications Rated voltage Vcc Red NPN type Lead wire color: Solenoid power AC100V: Yellow Solenoid power AC200V: White AC power supply Black AC100V: Yellow Interface solenoid AC200V: White valve Vcc Lead wire color: Input ― DC0V: Black Lead wire color: Input + DC5V: Red Interface solenoid valve AC100V: Yellow AC200V: White AC power supply Red PNP type Black 2. Control by TTL, IC Interface solenoid valve AC power supply AC100V: Yellow AC200V: White Black TTL Example: 7406 (able to control up to 2 interface 74LS244 solenoid valves.) 3. Control by relay contact Interface solenoid valve AC100V: Yellow Red Black AC200V: White AC power supply Vm<6.0V(Vm: Peak voltage) Vn>4.0V(Vn: Lowest voltage) Vn contact Vm Vcc 1. Separate the input side and solenoid side lead wires by color. Never apply AC power/6VDC or more to the input side. 2. Ensure that voltage ripple on the input side remains within the range shown below: 0V 4. When input is not a DC5V power supply Install resistance to the outside to drop the input voltage to 4〜6V. Vp Red AC power supply Black VcE R1 AC100V: Yellow Interface solenoid AC200V: White valve Example R1= Vp-5-VCE 〔Ω〕 18×10-3 Vp〔V〕 R1 12 390Ω1/4W 24 1.0KΩ1W In the case of VCE=0〔V〕 3. Even when a wrong polarity is applied to the input side, a built-in diode for protection against reverse polarity eliminates any worry about short circuiting. The valve will not operate, however. 4. A varistor and condensor are built-in to the solenoid power supply side, for protection circuit against external surge voltages. As a result, there is a 0.3mA leakage current in AC100V, and a 0.6mA leakage current in AC200V. 5. The operation and return times of the interface unit are 10ms or less with a 50Hz AC power supply, and 8ms or less with a 60Hz AC power supply. SOLENOID VALVES SERIES Cylinder Operating Speed Basic Models and Valve Functions How to obtain cylinder speed 030-4E1 Number of ports 2, 3 ports 5 ports Valve function Normally closed (NC) Single solenoid Remark: For optional specifications and order codes, see p.91〜92. Specifications Item Basic model Direct piping, T, F, F01 type manifolds 030E1 030-4E1 Air Media Operation type mm2 Effective area〔Cv〕 Direct acting type Internal pilot type 1 (P) →2 (A) 0.6〔0.03〕 2 (A) →3 (R) 0.8〔0.04〕 ( 1 P) →4 (A) ,( 2 B) 0.6 〔0.03〕 ( 4 A)→5(R1),( 2 B)→3(R2)0.8〔0.04〕 Port size Note M5×0.8 Lubrication Not required Operating pressure range MPa {kgf/cm2} [psi.] 0〜0.7 {0〜7.1} [0〜102] MPa {kgf/cm2} [psi.] 1.05 {10.7} [152] Response time ON/OFF DC12V, DC24V 10/25 or below AC100V, AC200V Maximum operating frequency 15/40 or below 5 Hz Operating temperature range (atmosphere and media) °C [°F] 5〜50 [41〜122] m/s2{G} Shock resistance 117.7 {12.0} Any Mounting direction t3 Time To obtain the time required for the cylinder to complete 1 stroke, add the cylinder’s delay time t1 (time between energizing of the solenoid valve and actual starting of the cylinder), to the cylinder’s max. speed operating time t2. When a cushion is used, add the cushioning time t 3 , to the above calculations. The standard cushioning time t3 is approximately 0.2 seconds. Measurement conditions 0.15〜0.7 {1.5〜7.1} [22〜102] Proof pressure ms t2 Cylinders start Solenoid valve energized t1 Cushioning impact 2 positions Number of positions Cylinder stop 030E1 Cylinder stroke Item Basic model Direct piping, T, F, F01 type manifolds ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Piping inner diameter and length: φ2.5 [0.1in.]×1000mm [39in.] ●Fitting: Quick fitting Valve side: TS4-M5 Cylinder side: TS4-M5 (φ10, φ16) TS4-01 (φ20) Load ●Load ratio= (%) Cylinder theoretical thrust ●Cylinder stroke: 60mm [2.36in.] (φ10,φ16) 100mm [3.94in.] (φ20) Load Cylinder Note: For details, see the port size on p.90. Solenoid valve 030-4E1 0.5MPa Fitting TS4-M5 or TS4-01 Solenoid Specifications Fitting TS4-M5 Maximum operating speed Rated voltage DC12V Item DC24V AC100V Type Operating voltage range V 10.8〜13.2 (12±10%) 21.6〜26.4 (24±10%) Frequency Hz ─ Starting mA (r.m.s.) Energizing mA (r.m.s.) Insulation resistance 90〜132 (100+32 −10 %) 180〜264 (200 +32 −10 %) ─ 50 60 50 60 ─ ─ 36 32 18 16 130 (1.6W) 65 (1.6W) 140 (1.7W) with LED indicator 75 (1.8W) with LED indicator 24 20 12 10 〔 〕 〔 8 〕 4 MΩ 4 Grommet type: 300mm [11.8in.] and lead wire length Optional Plug connector type: 300mm [11.8in.] Note: See made to order on p.97〜98. Color of LED indicator Surge suppression (as standard) 1000 800 600 φ10 [0.394in.] φ16 [0.630in.] 400 φ20 [0.787in.] 200 10 20 Over 100 Wiring type Standard Color of lead wire 1200 0 2 Red (+) Black (−) Brown (+) Black (−) Red Flywheel diode Yellow s White Yellow Green Varistor 30 40 Load ratio 50 60 70 % 1mm/s = 0.0394in./sec. Delay time Delay time Maximum allowable leakage current mA Shading type Maximum operating speed mm/s Flywheel diode incorporated for surge suppression Current (when rated voltage is applied) AC200V 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 φ20 [0.787in.] φ16 [0.630in.] φ10 [0.394in.] 10 20 30 40 Load ratio 50 60 70 % Note: Delay time changes depending on the valve construction, the volume of the cylinder and piping. Flow Rate Solenoid Valve Port Size MPa Supply pressure (MPa) Valve outlet pressure 0.7 0.6 Port specification Port size Female thread M5×0.8 ─ φ1.8 Female thread M5×0.8 ─ φ1.8 Port Location of piping ports Port size 1(P) Manifold 2(A) Valve 3(R) Manifold 1(P) Manifold 4(A), 2(B) Valve 3, 5(R) Manifold 1(P) Manifold Rc1/8 4(A), 2(B) Valve M5×0.8 3, 5(R) Manifold Rc1/8 1(P) 2(A) 0.7 3(R) 0.6 0.4 1(P) 0.5 0.3 0.3 0.2 0 Port 030E1 0.5 0.1 Basic model 0.4 4(A), 2(B) 030-4E1 3(R2), 5(R1) 0.2 0.1 10 20 30 40 50 Flow rate R/min (ANR) 1MPa = 145psi., 1R/min = 0.0353ft.3/min. How to read the graph When the supply pressure is 0.5MPa [73psi.] and flow rate is 29R/min [1.02ft.3 /min.] (ANR), the valve outlet pressure becomes 0.4 MPa [58psi.]. Manifold Port Size Manifold model YM□T YM□F YM□F01 Solenoid Valve Mass g [oz.] M5×0.8 M6×1 M5×0.8 M6×1 Manifold Mass g [oz.] Basic model Mass 030E1 57 [2.01] Manifold model 030-4E1 71 [2.50] YM□T (11×n)−1 YM□F (20.5×n)−1 [(0.72×n)−0.04] YM□F01 (20×n)+23 Mass calculation of each unit (n=number of units) Block-off plate [(0.39×n)−0.04].5 [(0.71×n)+0.81]. 3 [0.11] Operating Principles and Symbols 3-port Normally closed (NC) 2(A) 1(P) 3(R) 030E1 De-energized Column Solenoid cover Molded solenoid Energized Shading coil (AC solenoid only) Major Parts and Materials Parts Plunger Body Plunger spring O-ring Plunger pin Manual override Body Flapper Valve 1(P) 1(P) 2(A) 3(R) Flapper Manifold Single solenoid 4(A) 2(B) 5(R1) 1(P) 3(R2) 030-4E1 De-energized Energized Shading coil (AC solenoid only) Plunger Plunger spring Plunger pin Manual override Body 1(P) 1(P) 4(A) Flapper 2(B) Synthetic rubber (urethane) Plunger Magnetic stainless steel Spring Stainless steel Mounting base Mild steel (zinc plated) Body Aluminum alloy (anodized) Block-off plate Mild steel (zinc plated) Bracket Mild steel (nickel plated) Seal Synthetic rubber Remark: Materials that generate copper ions are not used for the non-ion specification. 5-port, 2-position Column Solenoid cover Molded solenoid Synthetic rubber Diaphragm Column 3(R) 2(A) Materials Aluminum alloy (anodized) 5(R1) 4(A) Diaphragm 5(R1) 3(R2) 3(R2) 2(B) Dimensions of Solenoid Valve (mm) 030E1 030-4E1 030E1 Approximately 300 24 15 15 24 Manual override Non-locking type:Standard Locking protruding type:-83 2(A) 2-M5×0.8 60.7 1(P) 12 2(B) 2(B) 2-φ2.8 Counterbore φ5.4 Depth 3 Mounting hole 1(P) 4(A) 4(A) 23.5 8 11 M5×0.8 11 Approximately 300 8.5 48.2 Manual override Non-locking type:Standard Locking protruding type:-83 2(A) 030-4E1 11 2-φ2.8 Counterbore φ5.4 Depth 3 Mounting hole 2-M3×0.5 Depth 2.5〜6.5 Mounting thread 2-M3×0.5 Depth 2.5〜6.5 Mounting thread M5×0.8 1(P) 1(P) 8.5 26.5 3 (R) 9 5(R1) 3(R2) 13 8 14 M5×0.8 2-φ1.8 18 18 φ1.8 9 ※The lead wire direction is to the opposite side from the manual override and A, B port. Additional Parts (To be ordered separately) Options Made to Order ●Mounting base:030-21 ●Locking protruding type manual override:-83 ●Solenoid with DIN connector:-39 030SOL φ14.8 (2.4) C (44.1) 6.5 1.6 54 M12×1.25 (34.5) φ6 13 (27) 7.5 E (To the top surface 5 of the valve) 030ROCK ●Solenoid with straight connector:-PSL 030SOL 34 ●Solenoid with LED indicator:-L 10 R 030SOL LED indicator 28 10 Approximately 24.5 300 28.2 A 34 36 24 2-φ4.5 Mounting hole 40 LED indicator ●Built-in interface unit:-FA ●Solenoid with L connector:-PLL 030SOL 030SOL 44 44.5 20 約300 D 29 B 20.5 30.5 R LED indicator LED indicator ※The lead wire direction is to the side with the manual override and 4(A), 2(B) port. Code A B C D E R (Lead wire length) Remarks 030E1 56 49 64.1 50.5 53.2 030-4E1 68.5 61.5 76.6 63 65.7 -PSL, -PLL: 300 Made to order: -1L: 1000, -3L: 3000 Overall length to the end of the valve Model Dimensions of Manifold for 2-, 3-port valves (mm) YMT YM□T L 8 16 16 8 15 15 Manual override Non-locking type:Standard Locking protruding type:-83 24 Approximately 300 2-M5×0.8 (With 1 plug) 2 15.5 22 7.5 M5×0.8 17.5 (R) 3 1(P) 20 Unit dimensions 20.5 030E1 Block-off plate 19 15 12 5 25 50 2-M3 Depth 4.5 Mounting thread Note 10 2-φ4.5 (Mounting hole) 8 P1 8 4-M3 Depth 4.5 Bracket mounting thread 16 P2 16 Note: Not available with YM2T stn. 1 stn. 2 Additional Parts (To be ordered separately) ●Muffler:KM-06 For manifold only 030MUFF Model L P1 YM2T 32 16 ─ YM3T 48 32 16 YM4T 64 48 32 YM5T 80 64 48 YM6T 96 80 64 YM7T 112 96 80 YM8T 128 112 96 YM9T 144 128 112 YM10T 160 144 128 Options Made to Order ●Locking protruding type manual override:-83 ●Solenoid with DIN connector:-39 030ROCK 030SOL φ6 φ14.8 16 6 13 (2.4) (34.5) (44.1) C ●Solenoid with straight connector:-PSL 54 M12×1.25 6.5 4 (11.5) P2 (27) 7.5 10 15 50.2 2-M6×1 (With 1 plug) 030SOL 10 Width across flats M6×1 34 10 ●Solenoid with LED indicator:-L R 030SOL 34 Approximately 24.5 300 28.2 36 A 10 LED indicator LED indicator ●Solenoid with L connector:-PLL ●Built-in interface unit:-FA 030SOL 030SOL 44 44.5 30.5 D 29 20.5 B 20 Approximately 300 R LED indicator LED indicator ※The lead wire direction is to the side with the manual override and 4(A), 2(B) port. Code A B C D R(lead wire length) Remarks 030E1 56 49 64.1 50.5 030-4E1 68.5 61.5 76.6 63 -PSL, -PLL: 300 Made to order: -1L: 1000, -3L: 3000 Overall length to the end of the valve Model Manifold for combination mounting of 2-, 3-, 5-port valves (mm) YMF YM□F L Manual override Non-locking type:Standard Locking protruding type:-83 8 16 16 8 15 15 24 Approximately 300 2-M5×0.8 (With 1 plug) 18.5 37 2 19 2-M5×0.8 31.5 1(P) 3・5(R) 15 10.5 22.5 35 62.7 2-M6×1 (With 1 plug) 030-4E1 Block-off plate 50 4-M3 Depth 4.5 Mounting thread Note 4 15 8 2-φ4.5 Mounting hole P1 8 8 4-M3×0.5 Depth 4.5 Bracket mounting thread stn. 1 stn. 2 4 5 26 25 Unit dimensions 16 P2 16 Note: 2 places for YM2F. Model L P1 YM2F 32 16 P2 ─ YM3F 48 32 16 YM4F 64 48 32 YM5F 80 64 48 YM6F 96 80 64 YM7F 112 96 80 YM8F 128 112 96 YM9F 144 128 112 YM10F 160 144 128 YMF01 YM□F01 L 18 16 6 16 15 18 15 10.5 24 Approximately 300 2-M5×0.8 4 15 5 25 50 Block-off plate 2-φ4.5 Mounting hole 33 1(P) 16 18 030-4E1 8 8 stn. 1 stn. 2 P2 8 4-M3×0.5 Depth 4.5 Bracket mounting thread 4-Rc1/8 (With 2 plugs) 3・5(R) 40 22.5 10.5 22.5 15 62.7 2-φ4.5 Mounting hole 42 Manual override Non-locking type:Standard 10.5 Locking protruding type:-83 P1 2 6 Unit dimensions Model L P1 P2 YM2F01 52 40 16 YM3F01 68 56 32 YM4F01 84 72 48 YM5F01 100 88 64 YM6F01 116 104 80 YM7F01 132 120 96 YM8F01 148 136 112 YM9F01 164 152 128 YM10F01 180 168 144 YM11F01 196 184 160 YM12F01 212 200 176 YM13F01 228 216 192 YM14F01 244 232 208 YM15F01 260 248 224 YM16F01 276 264 240 YM17F01 292 280 256 YM18F01 308 296 272 YM19F01 324 312 288 YM20F01 340 328 304 030 Series Solenoid Valve Order Codes ■ 2-, 3-port valve ■ Manual override Non-locking type manual override 3-port 2(A) ■ Wiring type ● Lead wire length: 300 mm [11.8in.] is standard. Number of ports Grommet type 1(P) 3(R) Blank Blank Locking protruding type manual override 2-port 2(A) Blank Straight connector with LED indicator 1(P) -2 -83 -PSL L connector with LED indicator -PLL Basic model 030E1 2-, 3-port Voltage -2 -83 Direct piping 030-4E1 5-port ●When ordering the non-ion specification, enter -NCU after the basic model code. Additional Parts Muffler Mounting base KM-06 ●For manifold only Block-off plate 030-21 ● YM F -BP YM─For YM T—For T type manifold F—For F type manifold (For F01 type manifold) -PSL -PLL DC12V DC24V AC100V AC200V 030 Series Manifold Order Codes ■ 2-, 3-port valve ■ Manual override Non-locking type manual override 3-port 2(A) ■ Wiring type ● Lead wire length: 300 mm [11.8in.] is standard. Number of ports Grommet type 1(P) 3(R) Blank Blank Locking protruding type manual override 2-port 2(A) Blank Straight connector with LED indicator L connector with LED indicator 1(P) -2 -83 -PSL -PLL Pre-wired common terminal Straight connector with LED indicator Pre-wired common terminal L connector with LED indicator -CPSL -CMSL -CPLL -CPLL -CMLL -CMLL ●-CP□L:Positive common of DC12V, DC24V, and AC100V, AC200V. ●-CM□L:Negative common of DC12V and DC24V. Manifold model Number of units Manifold for 2-, 3port valves Manifold for combination mounting of 2-, 3-, 5-port valves Station T 2 ⁝ 20 YM stn.1 ⁝ stn.n F F01 Basic model Voltage 030E1 -2 030E1 -2 -83 -CPSL -PSL -CMSL -PLL -CPLL -CMLL -83 030-4E1 ●For 11 or more stations, use F01 only. ●Specify the valve type for each station. ●Enter -BP when closing a station with a block-off plate without mounting a valve. ●When ordering the non-ion specification, enter -NCU after the basic model code. ●Valve mounting location from the lefthand side when facing the 4(A), 2(B) ports. Made to Order For details, see p.97〜98. Straight connector with LED indicator -PSLN ●Without lead wire ●Connector and contacts included L connector with LED indicator Lead wire length DIN connector -PLLN -1L -3L -39 ●Without lead wire ●Connector and contacts included ●For plug connector ●Cannot be used Length -1L:1000 with -L. (mm) [39in.] -3L:3000 [118in.] LED indicator with built-in varistor -L ●Cannot be used with -39. Built-in interface unit -FA ●Can be directly controlled by output from micro computer or other logic devices. ●With LED indicator DC12V DC24V AC100V AC200V ●Pre-wired common terminal for AC100V and AC200V is either -CPSL or -CPLL. ">
Advertisement
Key features
- 2/3-port and 5-port configurations
- Manual override
- LED indicators
- Surge suppression
- Plug connectors
- DIN connectors
- Built-in interface units
- Various wiring types
Frequently asked questions
The operating pressure range is 0 to 0.7 MPa {0 to 7.1 kgf/cm2} [0 to 102 psi.] for direct acting and 0.15 to 0.7 MPa {1.5 to 7.1 kgf/cm2} [22 to 102 psi.] for internal pilot.
Yes, the -FA option includes a built-in interface unit with photo transistor, allowing direct control by a microcomputer and logic chip.
The LED indicator provides visual confirmation of operation. It lights up when the solenoid is energized.