Koganei 240_4A Air piloted valve Instruction manual
Koganei 240_4A is a single pilot air-piloted valve designed for direct piping applications. It features a 2-position operation, 5 ports, and a closed center valve function (standard) or optional exhaust center. The valve utilizes a lip seal and flapper for smooth operation, and its compact design allows for easy installation.
PDF
Download
Document
Advertisement
Advertisement
BK-UV002 Ver.1.0 Air Valve SOLENOID VALVES 240 SERIES INSTRUCTION MANUAL Ver.1.0 Handling Instructions and Precautions Solenoid Plug connector Manual override Attaching and removing plug connector Internal circuit ●AC100V, AC200V Solenoid (Surge suppression) Order code: -ZR Standard solenoid Solenoid Use fingers to insert the connector into the pin, push it in until the lever claw latches onto the protruded section of the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the protruded section of the connector housing, and pull it out. Protruded section Varistor Pin Lead wire AC100V: Yellow AC200V: White Connector housing Lever Connector assembly Solenoid with LED indicator (Surge suppression) Order code: -PS-L -PL-L Non-locking type To operate the manual override, press it all the way down. For single solenoid, the valve works the same as when in the energized state as long as the manual override is pushed down, and returns to the normal position upon release. For the double solenoid, pressing the manual override on the 12(S1) side switches the 12(S1) to enter the energized position, and the unit remains in that state even after the manual override is released. To return it to the normal position, operate the manual override on the 14(S2) side. This is the same for the solenoids 14(S2). Indication of polarity (DC) LED indicator (Light Emitting Diode) Connector Contact C Diode ※Illustration shows the 110 series. Color of LED indicator AC100V: Yellow AC200V: Green ●DC24V Standard solenoid (Surge suppression) Short circuit protection diode (+) Lead wire: Red Solenoid Flywheel diode (−) Lead wire: Black Solenoid with LED indicator (Surge suppression) Order code: -PS-L -PL-L LED indicator (Light Emitting Diode) (+) Lead wire: Red (−) Lead wire: Black LED indicator: Red PU Crimping of connecting lead wire and contact To crimp lead wires into contacts, strip off 4mm [0.16in.] of the insulation from the tip of the lead wire, insert it into the contact, and crimp it. Be sure to avoid catching the insulation on the exposed wire crimping section. Exposed wire 4mm Contact Lead wire Equivalent to AWG22〜26 Insulation crimp tab Insulation(Maximum Hook Exposed wire crimping section outer diameterφ1.7) Cautions: 1. Do not pull hard on the lead wire. 2. Always use a dedicated tool for crimping of connecting lead wire and contact. Contact: Model 702062-2M Manufactured by Sumiko Tech, Inc. Crimping tool: Model F1-702062 Manufactured by Sumiko Tech, Inc. Attaching and removing contact and connector Insert the contact with lead wire into a plug connector □ hole until the contact hook latches on the connector and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove it, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook, and then pull out the lead wire. Cautions: 1. Do not pull hard on the lead wire. It could result in defective contacts, breaking wires, etc. 2. If the pin is bent, use a small screwdriver, etc. to gently straighten out the pin, and then complete the connection to the plug connector. SH ※Illustration shows the 110 series. Locking type To lock the manual override, use a small screwdriver to push down on the manual override all the way down and turn it 45 degrees. Either turning direction at this time is acceptable. When locked, turning the manual override from the locking position releases a spring on the manual override, returns it to its normal position, and releases the lock. When the manual override is not turned, this type acts just like the non-locking type. TURN PU SH ※Illustration shows the 240 series. Cautions: 1. The 240 series valves are pilot type solenoid valves. As a result, the manual override cannot switch the main valve without air supplied from the 1(P) port. 2. Always release the lock of the locking type manual overrides before commencing normal operation. 3. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. 4. Do not turn the adjusting knob more than needed. It could result in defective operation. Handling Instructions and Precautions Manifold t y u e End plate A 240M□A(W) r 240M□B(W) End plate B Port isolator q w Cautions: 1. For the 1(P) port piping, use a size that matches the manifold’s piping connection port. Insufficient flow rate or pressure could result in defective valve operation or in insufficient actuator output. 2. When installing piping or mufflers to the 3(R2) and 5(R1) ports, ensure there will be minimum exhaust resistance. On rare occasions, exhaust from valves can interference with other valves and actuators. 3. When a multiple number of valves operate simultaneously on a multiunit manifold, or when the manifold with valves is used at high frequency, supply air from the 1(P) ports on both ends, and exhaust air from the 3(R2), 5(R1) ports on both ends. 4. In bottom ported manifolds (B type and BW type), use of the bottom 1(P), 3(R2) and 5(R1) ports can prevent flow rate or pressure shortages, or exhaust interference. o 10 Illustration shows 240M□AW. Stacking unit order Piping The 1(P) port, 3(R2) port, 5(R1) port and PR port are on both ends of the manifold, and piping direction can be selected depending on the mounting location. At shipping, the ports on one side are plugged. Remove the plugs and then use sealing tape or another sealing agent to tighten in place. i If stacking part is required due to the addition or replacement of manifold units, use the following order codes to place orders. No. Parts — Stacking unit for 240M□A CR016 A type stacking unit (1): q joints (2), w joint mounting bolts (2), e valve mounting screws (3), r gasket (1), t gasket (1), y O-rings (3) — Stacking unit for 240M□B CR017 B type stacking unit (1): q joints (2), w joint mounting bolts (2), e valve mounting screws (3), r gasket (1), t gasket (1), y O-rings (3), u O-ring (1), Rc1/8 plugs (5), Rc1/4 plugs (2) — Stacking unit for 240M□AW CR018 AW type stacking unit (1): q joints (2), w joint mounting bolts (2), e valve mounting screws (3), r gasket (1), t gasket (1), y O-rings (3), i terminal block (1), o terminal cover (1), !0 connection cover (1) — Stacking unit for 240M□BW CR019 BW type stacking unit (1): q joints (2), w joint mounting bolts (2), e valve mounting screws (3), r gasket (1), t gasket (1), y O-rings (3), u O-ring (1), i terminal block (1), o terminal cover (1), !0 connection cover (1), Rc1/8 plugs (5), Rc1/4 plugs (2) i Terminal block CR020 Order codes Parts lists (quantities) Plug-in Stacking The A Type, B Type, AW Type and BW Type manifolds are the stacking type, for flexible addition or reduction of units. ●Assembly instructions 240M□A and 240M□B Loosening the joint mounting bolts (hexagon socket head bolts) w on both ends and removing the joint q lets the stations be separated. To add units, position the O-rings y and u and gasket t in the stacking unit stations, install the joint, and tighten the joint mounting bolts. 240M□AW and 240M□BW Loosen the set screw on the terminal cover, remove the terminal cover o and connection cover !0, and pull out the terminal block i. Loosening the joint mounting bolts on both sides and removing the joint lets the stations be separated. To add units, first position Orings and gaskets in the stations to be added, install the joint, and tighten the joint mounting bolts. Then, fit the terminal block, secure the terminal cover in place with mounting screws, and fit the connection cover. DIN connector Mounting and removing valves With the plug-in type, valves can be replaced while leaving the air piping or electrical wiring in place. Loosen the 3 valve mounting screws, and pull the valve straight out. To mount the valve, align the valve plug over the socket of the sub-base or manifold, and fit it straight in. Then tighten the valve mounting screws to secure it in place. Socket ●Piping port location With the 1(P) port on both ends and the bottom surface, the 4(A) and 2(B) ports on the side and bottom surfaces, and the 3(R2) and 5(R1) ports on both ends and the bottom surface, piping is allowed in any location. Use the plugs provided with the manifold, with sealing tape or another sealing agent, to block off the unused ports. Port isolator Port isolators on the 1(P), 3(R2) and 5(R1) ports can be used to separate them from adjacent stations, to allow supply of different pressures, or to prevent exhaust interference. Port isolators can be fitted and assembled between stations in place of the O-rings y to separate the 1(P), 3(R2) and 5(R1) ports from adjacent stations. For stations split by port isolators, plumb the 1(P), 3(R2) and 5(R1) ports on the bottom. Block-off plate To close up the unused stations, use a block-off plate (order code: -BP). ●Solenoid with DIN connector When de-sheathing (outer sheath of the cabtyre only), pay attention to the outlet direction of the lead wire. The cover will be easy to mount when the lead wire on the outer side of the terminal cover interior is set to about 8mm [0.31in.] longer than the inner side. Without stripping off the sheath, insert the lead wire until it contacts the lead wire stopper on the terminal body, and then place the contact from the upper side. Then use pliers to press the lead wire further to ensure that the contacts are firmly holding the core wire. JIS C3306 VCTF Electric conductor 0.75mm2 Finished outside 6.6(2 leads) 7.0(3 leads) Cable Plug 1 2 + 3 _ Cable gland Socket Solenoid terminal location Cable gasket Washer Contact Lead wire stopper Plug No.1 terminal (−) No. 2 terminal (−) No.1 terminal (+) No. 2 terminal (+) Bottom port Since the B Type and BW Type manifolds have piping ports on the bottom of the manifold, both the bottom and side ports can be used as required. Wiring instructions Wiring instructions In the plug-in type, the terminal block and solenoid are connected by a plug and socket. Loosen the terminal cover mounting screws, remove the terminal cover, and then pull out the terminal block and connect it. Fit the connected terminal block into the sub-base or manifold, mount the terminal cover, then secure the mounting screws in place. Connect the single solenoid leads to the No. 2 (+, −) terminal. In the double solenoid, the No.1 (+, −) terminals are connected to the valve’s solenoid 12 (S1), and the No.2 (+, −) terminals to the solenoid 14 (S2). For DC models, pay attention to the polarity. While a wrong in polarity will not cause a short circuit, the valve will not operate. For the terminal, use the round terminal JIS2805 R type 1.25-3 or equivalent. To order the terminal block and other parts for adding units, see the manifold parts order item on p.657. A collective common type manifold that uses crossover contacts can also be manufactured. Consult us. Lead wire Gasket Cover mounting screw Terminal cover Lead wire Gasket Terminal body Terminal body Pliers Note: The appropriate tightening torque for the cover mounting screw is 29.4N・cm {3kgf・cm} [2.6in・lbf]. SOLENOID VALVES SERIES Specifications Solenoid Specifications Basic Solenoid specifications model For direct piping Single solenoid For F type manifold For standard type sub-base For A type, B type manifolds For pug-in type sub-base For AW, BW type manifolds Item Media Operation type Number of positions, Number of ports 240-4E1 240-4E2 243-4E2 A240-4E1 A240-4E2 A243-4E2 W240-4E1 W240-4E2 W243-4E2 Air Internal pilot type 2 positions, 5 ports 3 positions, 5 ports ── Closed center (standard) or Exhaust center (optional) 16〔0.88〕(11.3〔0.62〕) Note 1 15〔0.83〕(11〔0.61〕) Note 1 Valve function mm2 Effective area〔Cv〕 Double solenoid 3-position double solenoid P, A, B: Rc1/4 R: Rc1/8 (P, A, B, R: Rc1/4 PR: Rc1/8) Note 2 Port size Not required Lubrication 0.17〜0.7 {1.7〜7.1} [25〜102] Operating pressure range MPa {kgf/cm2} [psi.] 1.05 {10.7} [152] Proof pressure MPa {kgf/cm2} [psi.] Response time DC24V 25/35 20/20 25/55 ms AC100V, AC200V 25/25 20/20 25/45 ON/OFF Operating temperature range (atmosphere and media) °C [°F] 5〜50 [41〜122] 1373.0 {140.0} Lateral direction Shock resistance m/s2 {G} 451.1 {46.0} 264.8 {27.0} 588.4 {60.0} Axial direction Any Mounting direction 5 Maximum operating frequency Hz ── 50 ── Minimum time to energize ms 160 [5.64] Mass 230 [8.11] 260 [9.17] g [oz.] (350 [12.35]Note 3, (420 [14.81]Note 3, (450 [15.87]Note 3, 400 [14.11]Note 4) 470 [16.58]Note 4) 500 [17.64]Note 4) Notes: 1. Effective area for A240-4E□, W240-4E□. 2. Port size of sub-base. 3. Mass of A240-4E□ with sub-base. 4. Mass of W240-4E□ with sub-base. Rated voltage Item Type AC200V Shading type Operating voltage range V Hz mA (r.m.s.) mA (r.m.s.) Allowable leakage current mA Insulation resistance MΩ Standard Current AC100V Frequency Starting (when rated voltage is applied) Energizing DC24V Flywheel diode incorporated for surge suppression 90〜132 180〜264 21.6〜26.4 +32 (100 +32 (24±10%) −10 %) (200 −10 %) 50 60 50 60 ─ 34 32 17 16 ─ 22 20 11 10 65 (1.6W) 〔 75(1.8W) with LED indicator 〕 4 2 4 Over 100 Grommet type: 300mm [11.8in.] Plug connector type Straight connector Wiring type -PS: 300mm [11.8in.]※ -PSN: Without lead wire (connector, contacts included) Standard L connector -PL: 300mm [11.8in.]※ type Optional -PLN: Without lead wire (connector, contacts included) ※1000 [39in.], 3000mm [118in.] also available as options. Specify separately when ordering -1L: 1000, -3L: 3000. Plug-in type Color of lead wire Color of LED indicator (optional) Terminal type (Sub-base comes with conduit cover, and manifold with terminal cover) Yellow Yellow White Green Built-in varistor (optional) Surge suppression Red (+), Black (−) Red Flywheel diode (as standard) Remarks: For optional specifications and order codes, see p.637〜639. Manifold Specifications and Port Size Manifold model Specifications 240M□F 1(P), 3(R2), 5(R1) manifold piping 4(A), 2(B) valve piping 240M□A All port manifold piping 240M□AW All port manifold piping plug-in type 240M□B All port manifold piping bottom ported 240M□BW All port manifold piping bottom ported plug-in type Port size Applicable valve model 240-4E1 1(P) 240-4E2 Rc1/4 4(A), 2(B) 243-4E2 3(R2), 5(R1) 1(P) A240-4E1 Rc1/4 4(A), 2(B) A240-4E2 3(R2), 5(R1) A243-4E2 PR Rc1/8 1(P) W240-4E1 4(A), 2(B) Rc1/4 W240-4E2 3(R2), 5(R1) W243-4E2 PR Rc1/8 1(P) End plate 4(A), 2(B) Rc1/4 and side A240-4E1 3(R2), 5(R1) port A240-4E2 Rc1/8 PR A243-4E2 1(P) Bottom 4(A), 2(B) Rc1/8 port 3(R2), 5(R1) 1(P) End plate 4(A), 2(B) Rc1/4 and side W240-4E1 3(R2), 5(R1) port W240-4E2 PR Rc1/8 W243-4E2 1(P) Bottom 4(A), 2(B) Rc1/8 port 3(R2), 5(R1) Remarks Piping not allowed on the PR port. By using port isolators, the 1(P), 4(A), 2(B), 3(R2) and 5(R1) ports can be selected on either the end plate, side piping or bottom piping (the PR port is available only on the end plate). By using port isolators, the 1(P), 4(A), 2(B), 3(R2) and 5(R1) ports can be selected on either the end plate, side piping or bottom piping (the PR port is available only on the end plate). For order codes, see p.637〜639. Manifold Mass Manifold model Mass calculation of each unit (n=number of units) 240M□F (69×n)+69 [(2.43×n)+2.43] 240M□A (167×n)+217 [(5.89×n)+7.65] 240M□AW (199×n)+270 [(7.02×n)+9.52] 240M□B (167×n)+217 [(5.89×n)+7.65] 240M□BW (199×n)+270 [(7.02×n)+9.52] g [oz.] 240-4E1 240-4E2 243-4E2 160 [5.64] 230 [8.11] 260 [9.17] ── ── ── Mounting valve Block-off plate A240-4E1 A240-4E2 A243-4E2 W240-4E1 W240-4E2 W243-4E2 ── ── ── 160 [5.64] 230 [8.11] 260 [9.17] ── ── ── 160 [5.64] 230 [8.11] 260 [9.17] ── ── ── ── ── ── 160 [5.64] 230 [8.11] 260 [9.17] ── ── ── 160 [5.64] 230 [8.11] 260 [9.17] 30 [1.06] ── ── ── Calculation example: The mass of 240M10F stn. 1〜5-240-4E1 stn. 6〜10-240-4E2, (69×10)+69+(160×5)+(230×5)=2709g [95.56oz.]. 240-4E1 A240-4E1-25 Flow rate Flow rate MPa 0.7 0.6 0.5 Valve outlet pressure Valve outlet pressure 0.6 0.7 0.7 Supply pressure (MPa) 0.6 0.4 0.5 0.3 0.4 0.3 0.2 0.4 1MPa=145psi. 1R/min.=0.0353ft.3/min. 0.1 0 500 1000 Flow rate 0.2 0.1 1500 2000 R/min(ANR) mm/s 1200 Maximum operating speed Maximum operating speed 1000 800 φ40 [1.575in.] φ50 [1.969in.] 600 φ63 [2.480in.] 400 φ80 [3.150in.] φ100 [3.937in.] 200 30 40 50 60 Load ratio φ40 [1.575in.] φ50 [1.969in.] 600 φ63 [2.480in.] 400 φ80 [3.150in.] φ100 [3.937in.] 200 0 10 20 30 40 50 Load ratio s φ100 [3.937in.] φ80 [3.150in.] φ63 [2.480in.] φ50 [1.969in.] φ40 [1.575in.] 10 20 30 40 50 Load ratio 60 70 % φ80 [3.150in.] φ63 [2.480in.] φ50 [1.969in.] φ40 [1.575in.] 10 20 30 40 50 Load ratio ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Piping inner diameter and length: φ7.5× 1000mm [39in.] ●Fitting: Quick fitting TS10-02 Load ●Load ratio= (%) Cylinder theoretical thrust ●Cylinder stroke: 300mm [11.8in.] Cylinder Measurement conditions Solenoid valve ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] 240-4E1 ●Piping inner diameter and length: φ7.5× 1000mm [39in.] ●Fitting: Quick fitting TS10-02 Load ●Load ratio= (%) 0.5MPa Cylinder theoretical thrust ●Cylinder stroke: 300mm [11.8in.] Fitting TS10-02 Cylinder stroke How to obtain cylinder speed t2 t3 time Cylinder Cushioning Cylinder start impact stop 60 70 % Solenoid valve A240-4E1-25 Measurement conditions t1 70 % φ100 [3.937in.] 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 Load Solenoid valve energized 60 Delay time Delay time Delay time 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 1000 1500 2000 Flow rate R/min(ANR) 800 70 % Delay time s 500 1000 1mm/s=0.0394in./sec. 20 0.1 Maximum operating speed mm/s 1200 10 0.3 0.2 0 Maximum operating speed 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure (MPa) 0.7 0.5 To obtain the time required for the cylinder to complete 1 stroke, add cylinder’s delay time t1 (time between energizing of the solenoid valve and actual starting of the cylinder), to the cylinder’s max. speed operating time t 2. When a cushion is used, add the cushioning time t3, to the above calculations. The standard cushioning time t 3 is approximately 0.2 seconds. Load 0.5MPa Cylinder MPa Fitting TS10-02 240 Series Solenoid Valve, Air-piloted Valve Order Codes 3-position valve Valve function Closed center 4(A) 5(R1) 2(B) 1(P) Mounting base Sub-base Speed controller Manual override Wiring type (standard type) Wiring type (plug-in type) Without mounting base Side piping standard type Without speed controller Non-locking type Grommet type Standard plug-in Varistor 3(R2) Blank -25 Blank Blank Blank Standard Exhaust center 4(A) 5(R1) 2(B) 1(P) With mounting base With speed controller Side piping plug-in type Blank -ZR Blank Standard Locking type With built-in varistor for surge suppression Straight connector with LED indicator With LED indicator Diode 3(R2) -13 -21 -26 -70 -81 -PS-L With lead wire Side and bottom piping standard type -PSN-L -L Without lead wire Connector, contacts included L connector with LED indicator With built-in varistor for surge suppression Varistor -27 -PL-L With lead wire Side and bottom piping plug-in type DIN connector -28 -PLN-L -ZR Without lead wire Connector, contacts included -39 Basic model Direct piping Standard sub-base piping Plug-in sub-base piping Single solenoid 240-4E1 2-position double solenoid 3-position double solenoid 240-4E2 Single solenoid A240-4E1 243-4E2 2-position double solenoid 3-position double solenoid A240-4E2 Single solenoid W240-4E1 2-position double solenoid 3-position double solenoid W240-4E2 A243-4E2 W243-4E2 Note 2 Direct piping air-piloted valves (made to order) Single pilot 240-4A Double pilot 240-4A2 Sub-base piping air-piloted valves (made to order) Single pilot A240-4A Double pilot A240-4A2 Notes: 1. Attached to the sub-base. 2. Because the long valve body interferes with the connector, no sub-base is set in the order codes. ●When ordering the non-ion specification, enter -NCU after the basic model code. -21 Plug-in type sub-base -26 ●Side piping type -21 -81 -70 -13 -81 -81 -25 -27 -70 Note 1 -13 -81 -26 -28 -70 Note 1 -13 -ZR,-39 -PS-L -PSN-L -PL-L -PLN-L DC24V AC100V AC200V -ZR,-39 -PS-L -PSN-L -PL-L -PLN-L DC24V AC100V AC200V -81 -L -ZR -81 -21 DC24V AC100V AC200V -70 -25 -27 -70 Note 1 ●Not available for 240-4E2,A240-4E2,W240-4E2. ●-ZR: Varistor for surge suppression is available for AC100V and AC200V only (flywheel diode for surge suppression is standard equipment for DC24V) and a varistor for surge suppression is built into AC100V and AC200V with LED indicator. ●Color of LED indicator AC100V: yellow, AC200V: green, DC24V: red ●-PS-L,-PL-L: Lead wire length can be selected. When ordering, specify -1L: 1000, -3L: 3000. Lead wire length: mm [in.] 300 [11.8]—Standard 1000 [39], 3000 [118]—Optional Options Mounting base Voltage Speed controller -28 ●Side and bottom piping type -70 ●Attached to the subbase in the case of sub-base type. Manual override -81 ●Locking type Straight connector L connector -PS-L -PL-L ●With lead wire and LED indicator Surge suppression ●With lead wire and LED indicator Surge suppression DIN connector -39 240 Series Manifold Order Codes 3-position valve Valve function Manual override Wiring type (standard type) Wiring type (plug-in type) Closed center Non-locking type Grommet type Standard plug-in 4(A) 5(R1) 2(B) 1(P) Varistor 3(R2) Blank Blank Standard Exhaust center 4(A) 5(R1) 2(B) 1(P) Blank -ZR Blank Standard With built-in varistor for surge suppression Straight connector with LED indicator Locking type With LED indicator Diode 3(R2) -13 -81 -PS-L With lead wire -PSN-L Without lead wire Connector, contacts included L connector with LED indicator -L With built-in varistor for surge suppression Varistor -PL-L With lead wire DIN connector -PLN-L -ZR Without lead wire Connector, contacts included -39 Manifold model Number of units Station stn.□ ⁝ stn.□ -240-4E1 stn.□ ⁝ stn.□ -A240-4E1 stn.□ ⁝ stn.□ -W240-4E1 AW BW F stn.□ ⁝ stn.□ -240-4A A B stn.□ ⁝ stn.□ F Manifold for mounting 5-port valves Manifold for mounting 5-port valves (made to order) 240M 240M 2 ⁝ 10 2 ⁝ 10 A B ●Valve mounting location from the left-hand side when facing the 4(A), 2(B) ports. Made to order Air-piloted valves 240 series ●5-port, 2-position ●Single pilot ●Double pilot Basic model Voltage -81 -240-4E2 -243-4E2 -13 -81 -81 -A240-4E2 -A243-4E2 -13 -81 DC24V AC100V AC200V -ZR,-39 -PS-L -PSN-L -PL-L -PLN-L DC24V AC100V AC200V -81 -L -ZR -W240-4E2 -W243-4E2 -ZR,-39 -PS-L -PSN-L -PL-L -PLN-L -13 -81 DC24V AC100V AC200V -240-4A2 -A240-4A -A240-4A2 ●Specify the valve model for each station. ●Enter -BP when closing a station with a block-off plate without mounting a valve. ●When ordering the non-ion specification, enter -NCU after the basic model code. Manifold for Serial Transmission System Order Codes Wiring type Side piping AW type manifold For right side For left side mounting mounting ASR ASL Serial transmission module 3-position valve Valve function Manual override Wiring type -OR: OMRON -MB: Mitsubishi Electric -FJ: Fuji Electric FA Components & Systems -SP: SHARP -MS: Matsushita Electric Works -HT: Hitachi Blank: Closed center -13: Exhaust center Blank: Nonlocking type manual override -81: Locking type manual override -L: Plug-in type Bottom piping BW type manifold For right side For left side mounting mounting BSR BSL Basic model Station 2 ⁝ 10 240M Note: Serial transmission systems are only available for solenoid specification DC24V with LED indicator. ASR ASL BSR BSL -OR -MB -FJ -SP -MS -HT stn.□ ⁝ stn.□ Basic model -W240-4E1 -81 -W240-4E2 -W243-4E2 ●Valve mounting location from the lefthand side when facing the 4(A), 2(B) ports. (□: 1〜10) ●The serial transmission module is not counted as a station. ●Depending on the number of control outputs in the product’s unit, up to 16 solenoid coils can be installed. W24□-4E2 can be operated with a maximum of 8 units, while W240-4E1 can be operated with a maximum of 16 units. 1. The address number is sticked on the solenoid at shipping. 2. The 11〜16 units are special specifications. Voltage -L -13 DC24VNote -81 ●Specify the valve model for each station. ●Enter -BP when closing a station with a block-off plate without mounting a valve. ●To increase units in the manifold, order the manifold stacking units. Symbols Single solenoid 2-position double solenoid 3-position double solenoid Closed center 14(S2) 14(S2) 4 (A) 2(B) 4 (A) 2(B) 5(R1) 1(P) 3 (R2) Exhaust center 4(A) 2(B) 5(R1) 1(P) 3(R2) 14(S2) 5(R1) 1(P) 3(R2) 4(A) 2(B) 5(R1) 1(P) 3(R2) 12(S1) 12(S1) Operating Principles and Major Parts 12(S1) Major Parts and Materials Parts ●240-4E1 Solenoid cover Column De-energized Energized Shading coil (AC solenoid only) Body Stem Aluminum alloy (anodized) Lip seal Flapper Molded solenoid Materials Aluminum alloy (treated with chromic acid) Synthetic rubber Mounting base Mild steel (zinc plated) Plunger spring Sub-base Aluminum alloy (anodized) Manual override Plunger Plunger pin Column Magnetic stainless steel Plunger PR Remark: Materials that generate copper ions are not used for the nonion specification. Piston Pilot valve body Flapper 5(R1) 5(R1) Stem 4(A) 4(A) 1(P) Body 1(P) 2(B) 2(B) 3(R2) 3(R2) Lip seal End cover ●240-4E2 ●243-4E2 ●243-4E2-13 (De-energized condition after energizing solenoid 12(S1)) (Both solenoid 12(S1)and 14(S2)are de-energized.) (Both solenoid 12(S1)and 14(S2)are de-energized.) 14(S2) 14(S2) 14(S2) 5 (R1) 4(A) 1(P) 4(A) 2(B) 4(A) 1(P) 1(P) 3(R2) 2(B) 2(B) 12(S1) 12(S1) 12(S1) Dimensions of Solenoid Valve (mm) 240-4E1 ●240-4E1 Approximately 35 300 23 Manual override Non-locking type: Standard Locking type: -81 PR1 2-Rc1/8 2-φ3.3 5(R1)Port Mounting hole 2-φ3.3 Counterbore R3 Depth 3 Mounting hole 4(A)Port 1(P)Port R1 36 19.6 22 40 103.2 A 2 9 3-Rc1/4 35.5 R2 3(R2)Port 8 17.5 24.5 15.5 2 9 PR2 3 3 2-M3×0.5 Depth 4 Mounting thread 11.5 11.5 2(B)Port 25.7 P B 7 7 240-4E2 ●240-4E2 Approximately 300 35 23 2-PR 2-Manual overrides Non-locking type 2-φ3.3 Counterbore R3 Depth 3 Mounting hole 4(A)Port 1(P)Port 2(B)Port 40 36 19.6 R1 22 A P B 67.7 3(R2)Port 12 (S1) 3-Rc1/4 2 2 9 9 8 3 3 49.7 56.7 57.9 R2 47.7 135.4 2-Rc1/8 2-φ3.3 Mounting hole 5(R1)Port 14 (S2) 243-4E2 ●243-4E2 Approximately 35 300 23 2-Manual override Non-locking type: Standard Locking type: -81 2-PR 14 (S2) 2-φ3.3 Counterbore R3 Depth 3 Mounting hole 4(A)Port 1(P)Port R1 36 22 40 19.6 2(B)Port A 165.4 2-Rc1/8 2-φ3.3 Mounting hole 5(R1)Port P B 82.7 3(R2)Port 64.7 72.9 62.7 71.7 R2 12 (S1) 3-Rc1/4 8 2 2 9 9 3 3 Options ●Straight connector with LED indicator: -PS(N)-L 240SOL 108.8 (To the top surface of the valve) 5.6 ●Mounting base: -21 240SC 23 22 2 11 0.5 41 10 35 31 2-φ4.5 Mounting hole 240-4E1:110.5 240-4E2:150 243-4E2:180 R (Overall length of the valve) 1.6 B 0.5 ●With built-in varistor for surge suppression: -ZR Dimensions are the same as the standard product. 6 LED indicator 18 18 46 ●L connector with LED indicator: -PL(N)-L 240SOL R 23 0.5 (21) 17 11 23.5 23.7 10 Width across flats R1/8 52 DIN connector (-39) 21 22 11.4 2 ●DIN connector: -39 240SOL LED indicator Manual override 240-4E1:117.2 240-4E2:163.4 243-4E2:193.4 (Overall length of the valve) (32.5) (25.1) ●Speed controller: -70 240SC 2.4 13 63 10 31 M12×1.25 φ14.8 S2 14.8 Dimensions of Solenoid Valve (mm) A240-4E1 ●A240-4E1-25 ●A240-4E1-27 82.5 43 9 23 21 10 11 Approximately 300 Manual override Non-locking type: Standard Locking type: -81 38.5 43 35 27.5 21 Rc1/8 PR 5(R1) 5-Rc1/4 34 2-φ4.5 Mounting hole 10 5.5 4.5 3(R2) 30 40 1(P) 58.5 68.5 21 19.5 2(B) 55 4(A) 103.2 PR A 4.5 〈Viewed from A〉 -27: Bottom port M5×0.8 PR 5-Rc1/4 5(R1)Port 4(A)Port PR R A 1(P)Port 23 40 30 R 18.5 55 P B 2 (B)Port 10 3(R2)Port 10.5 25 34.5 A240-4E2 ●A240-4E2-25 ●A240-4E2-27 43 9 23 21 10 82.5 11 Approximately 300 2-Manual overrides Non-locking type 43 35 27.5 21 14 (S2) Rc1/8 PR 38.5 34 4.5 40 30 10 3(R2) 4.5 37.7 12 (S1) 2-φ4.5 Mounting hole 1(P) 68.5 135.4 21 19.5 2(B) 55 4(A) 58.5 5(R1) PR 5-Rc1/4 A A243-4E2 ●A243-4E2-25 ●A243-4E2-27 82.5 43 23 9 21 10 11 38.5 Approximately 300 2-Manual overrides Non-locking type: Standard Locking type: -81 43 35 27.5 21 14 (S2) Rc1/8 PR 3(R2) 30 40 1(P) 58.5 52.7 10 4.5 165.4 21 19.5 2(B) 55 4(A) 68.5 5(R1) PR 5-Rc1/4 A 12(S1) 〈Viewed from A〉 34 2-φ4.5 Mounting hole -27: Bottom port 4.5 M5×0.8 PR 5-Rc1/4 5(R1)Port 4 (A)Port PR R A 1(P)Port 23 55 40 P 10 30 18.5 R B 2 (B)Port 3(R2)Port 10.5 25 34.5 Options ●Straight connector with LED indicator: -PS(N)-L 240SOL (21) ●Dimensions for the built-in varistor for surge suppression are the same as for the standard product. ●DIN connector: -39 240SOL DIN connector (-39) 240-4E1:117.2 240-4E2:163.4 243-4E2:193.4 (Overall length of the valve) (32.5) (25.1) Manual override 2.4 13 2 11 63 10 96 (To the bottom of the sub-base) 10 R 23 2.5 52 0.5 22 21 2 11 13.5 LED indicator LED indicator 31 M12×1.25 φ14.8 S2 14.8 85 (To the bottom of the sub-base) 0.5 41 23.7 14 Width across flats R1/4 22 A240-4E1: 110.5 A240-4E2: 150 R A243-4E2: 180 (Overall length of the valve) 31 16.2 23 0.5 ●L connector with LED indicator: -PL(N)-L 240SOL 23.5 ●Speed controller:-70 240SC Dimensions of Solenoid Valve (mm) 43 82.5 20.6 ●W240-4E1-26 ●W240-4E1-28 φ10 9 28 8.5 23 11 (9) W240-4E1 60 52.5 Manual override Non-locking type: Standard Locking type: -81 34 40 30 21 4.5 2-φ4.5 Mounting hole 21 -28: Bottom port M5×0.8 PR 5-Rc1/8 10 3(R2) 10 〈Viewed from A〉 1(P) 58.5 5.5 4.5 19.5 2(B) 5-Rc1/4 A 5(R1) 139 68.5 21 4(A) 103.2 PR 55 133.5 Rc1/8 PR 27.5 38.5 5(R1)Port 43 4 (A)Port PR R A 1(P)Port 43 11 (9) 23 60 2-Manual overrides Non-locking type 30 8.5 23 18.5 9 W240-4E2 28 10 φ10 40 P 82.5 20.6 55 ●W240-4E2-26 ●W240-4E2-28 R B 3(R2)Port 10.5 25 52.5 34.5 14(S2) 30 40 4.5 37.7 5-Rc1/4 10 3(R 2) 2(B) 19.5 A 1(P) 58.5 21 68.5 4(A) 135.4 5(R 1) 171.2 PR 55 133.5 Rc1/8 PR 12(S1) 10 21 21 27.5 2-φ4.5 Mounting hole 34 4.5 38.5 43 Options ●With LED indicator: -L ●Speed controller: -70 240SC 85 (To the bottom of the sub-base) 41 0.5 (21) 16.2 23 22 10 2.5 23.7 14 Width across flats R1/4 0.5 LED indicator ● Plug-in type with built-in varistor for surge suppression: -ZR Dimensions are the same as the standard product. 2(B)Port Dimensions of Manifold (mm) 240MF ●240M□F Approximately 300 L 5 P 24 5 24 12.5 24 23 28 24 23 Manual override Non-locking type: Standard Locking type: -81 64 35 19 12.5 4-φ4.5 Mounting hole 11 10 6-Rc1/4 (with 3 plugs) 14 (S2) A A A 2 2 (B)Port 16 51.7 2 12 (S1) Rc1/4 40 23 11 B 31 3(R2) 62 165.4 20 B 4(A)Port 4.5 36.7 B 21 22 35.5 24.5 B 52 1(P) 98.7 A 5(R1) 67.7 14 (S2) 12 (S1) 240-4E1 240-4E2 243-4E2 Block-off plate (-BP) Unit dimensions stn.1 stn.2 stn.3 stn.4 Model L P 240M2F 72 62 240M3F 96 86 240M4F 120 110 240M5F 144 134 240M6F 168 158 240M7F 192 182 240M8F 216 206 240M9F 240 230 240M10F 264 254 stn.5 Options ●Straight connector with LED indicator: -PS(N)-L 70 240SOL (To the bottom of the manifold) 11 23 0.5 22 21 2 11 17 ●DIN connector:-39 240SOL DIN connector (-39) Manual override 6 LED indicator LED indicator 240-4E1:117.2 240-4E2:163.4 243-4E2:193.4 (Overall length of the valve) (32.5) (25.1) 2 81 (To the bottom of the manifold) R 52 41 10 23.5 22 240-4E1:110.5 240-4E2:150 243-4E2:180 R (Overall length of the valve) 31 0.5 0.5 23.7 23 ● Built-in varistor for surge suppression: -ZR Dimensions are the same as the standard product. ●L connector with LED indicator: -PL(N)-L 240SOL 2.4 13 63 10 31 M12×1.25 φ14.8 S2 14.8 Dimensions of Manifold (mm) 240MA ●240M□A ●240M□B L 5 P 44.5 33 87 5 28 28 44.5 23 23 Approximately 4-R2.5 300 Mounting hole 33 Manual override Non-locking type: Standard Locking type: -81 12.5 38.5 47.5 35 37 32 6-Rc1/4 17 A R1 R1 A R1 A A R1 A A P B P R2 R2 B P P B P B R2 3(R2)Port R2 41 B 1(P)Port 22 47 B 30 B 41.5 5(R1)Port 16 B 26.5 〈Viewed from A〉240M□B: Bottom port 4(A)Port 2-Rc1/4 per each station B 15.5 42.2 Block-off plate (-BP) B A243-4E2 R2 A240-4E2 2-Rc1/8 PR R1 A240-4E1 3 7.5 5 27.2 PR 3(R2) 31 1(P) 165.4 79 64 79 53 103.2 5(R1) 15 5 3 29.2 44.2 12.5 37.5 2(B)Port A stn.1 1 5 11.5 A A stn.2 stn.3 2(B)Port A A stn.4 stn.5 6.5 14 30.5 28 4(A)Port 5-Rc1/8 per each station 14 7.5 28 30.5 Unit dimensions 4 Model L P 240M2A, 240M2B 117 107 240M3A, 240M3B 145 135 240M4A, 240M4B 173 163 240M5A, 240M5B 201 191 240M6A, 240M6B 229 219 240M7A, 240M7B 257 247 240M8A, 240M8B 285 275 240M9A, 240M9B 313 303 240M10A, 240M10B 341 331 Options ●Straight connector with LED indicator: -PS(N)-L 240SOL 89.5 ●With built-in varistor for surge suppression: -ZR Dimensions are the same as the standard product. ●L connector with LED indicator: -PL(N)-L 240SOL (To the bottom of the manifold) 2 11 41 100.5 10 22 (To the bottom of the manifold) 0.5 2 52 ●DIN connector: -39 21 22 DIN connector (-39) 13.5 11 Manual override 23.7 A240-4E1:110.5 A240-4E2:150 R A243-4E2:180 (Overall length of the valve) 31 R 23 2.5 LED indicator LED indicator 240-4E1:117.2 240-4E2:163.4 243-4E2:193.4 (Overall length of the valve) (32.5) (25.1) 0.5 0.5 23.5 23 240SOL 2.4 13 63 10 31 M12×1.25 φ14.8 S2 14.8 Dimensions of Manifold (mm) 240MAW ●240M□AW 87 ●240M□BW 38.5 L 5 5 28 28 23 33 Manual override Non-locking type: Standard Locking type: -81 37 P 44.5 47.5 32 44.5 21.5 33 23 12.5 2-G1/2 17 12.5 4-R2.5 Mounting hole 6 6-Rc1/4 44.2 14(S2) W240-4E2 W243-4E2 31 41.5 15.5 26.5 3(R 2) PR 42.2 12(S1) W240-4E1 A 3 7.5 5 27.2 12(S1) 110.5 5(R1) 1(P) 167.7 79 53 64 79 152.7 103.2 125.5 15 5 29.2 14(S2) 2-Rc1/8 Block-off plate (-BP ) 2-Rc1/4 per each station B B B B 37.5 B A stn.1 1 5 11.5 A A stn.2 A stn.3 A stn.4 stn.5 〈Viewed from A〉240M□BW: Bottom port 4(A)Port 2(B)Port 4 5(R1)Port Unit dimensions 341 331 Options 23 22 2.5 23.7 0.5 10 LED indicator R2 B R2 P 22 41 47 30 16 6.5 (R2)Port 3 89.5 (To the bottom of the manifold) 0.5 41 ●With LED indicator: -L R1 303 240M10AW, 240M10BW P 313 (B)Port 2 B 275 240M 9 AW, 240M 9 BW A 247 285 (P)Port 1 R2 257 240M 8 AW, 240M 8 BW R1 240M 7 AW, 240M 7 BW P 219 B 229 R1 191 240M 6 AW, 240M 6 BW A 163 201 P 173 240M 5 AW, 240M 5 BW B R2 240M 4 AW, 240M 4 BW R1 135 A 107 145 P 117 240M 3 AW, 240M 3 BW B R2 240M 2 AW, 240M 2 BW A P A L R1 4(A)Port Model 30.5 14 28 5-Rc1/8 per each station 14 7.5 28 30.5 ●Plug-in type with built-in varistor for surge suppression: -ZR Dimensions are the same as the standard product. Dimensions of Serial Transmission System (mm) 240MASL ●240M□ASL, 240M□BSL 37 32 L (5) P Manual override 44.5 12.5 28 17 12.5 4-R2.5 (Mounting hole) Applicable cable outer diameterφ8.5〜φ12.5 stn.2 stn.3 stn.4 stn.5 stn.6 2-Rc1/4 per each station 161.8 4(A) 4(A) 2(B) 4(A) 4(A) 2(B) 2(B) 4(A) 4(A) 2(B) 2(B) 4(A) 1 4 A Bottom port〈Viewed from A〉 Unit dimensions 313 8 331 341 9 359 369 10 387 397 47 22 41 303 16 285 7 30 275 5(R1) 257 6 4(A) 3(R2) 3(R2) 4(A) 247 1(P) 229 5 2(B) 5(R1) 201 219 3(R2) 4(A) 191 4 1(P) 3 2(B) 5(R1) 6.5 3(R2) 4(A) 30.5 14 1(P) 28 14 2(B) 5(R1) 28 7.5 3(R2) 1(P) 4(A) 30.5 173 1(P) L 163 2(B) P 2 2(B) 5(R1) Number of units 47.5 2(B) 11.5 4(A) 2(B) 5 69.3 2(B) 37.5 stn.1 167.7 108.2 27.2 3 79 15 125.5 44(MAX.) 2-Rc1/8 36.5(MAX.) 41.5 15.5 64 31 26.5 125.5 5 6-Rc1/4 42.2 6 29.2 5 21.5 Dimensions of Serial Transmission System (mm) ●240M□ASR, 240M□BSR 37 L 32 (5) 21.5 5 P Manual override 17 28 44.5 12.5 12.5 6 4-R2.5 (Mounting hole) 125.5 36.5(MAX.) 3 27.2 2-Rc1/8 44(MAX.) 64 108.2 79 167.7 42.2 41.5 15.5 31 26.5 125.5 15 5 29.2 6-Rc1/4 Applicable cable outer diameterφ8.5〜φ12.5 stn.1 161.8 stn.2 stn.3 stn.4 stn.5 stn.6 11.5 4(A) 2(B) 4(A) 5 37.5 47.5 2(B) 4(A) 2(B) 2(B) 4(A) 2(B) 4(A) 2(B) 4(A) 2(B) 4(A) 2(B) 69.3 2-Rc1/4 per each station 4(A) 1 4 A Bottom port〈Viewed from A〉 Unit dimensions 341 9 359 369 10 387 397 47 22 41 331 16 313 8 30 303 5(R1) 285 7 4(A) 3(R2) 4(A) 275 1(P) 257 6 2(B) 5(R1) 247 3(R2) 4(A) 229 5 1(P) 201 219 2(B) 5(R1) 191 4 3(R2) 4(A) 3 1(P) 6.5 2(B) 5(R1) 30.5 14 3(R2) 4(A) 28 14 1(P) 28 7.5 3(R2) 30.5 173 1(P) L 163 2(B) P 2 2(B) 5(R1) Number of units Made to Order Air-piloted valves 240 series ●The optimum air valve for master valves or pilot valves for all-pneumatic control. Specifications For direct piping F type manifold For sub-base For A type and B type manifolds Single pilot Double pilot A240-4A A240-4A2 Single pilot Double pilot 240-4A 240-4A2 Item Basic model Air Media Air piloted type Operation type 2 positions, 5 ports Number of positions, Number of ports 16〔0.88〕 11.3〔0.627〕 Effective area〔Cv〕 mm2 Main 1(P) , 4(A) , 2(B) :Rc1/4 3(R2) , 5(R1) :Rc1/8 1(P) , 4(A) , 2(B) , 3(R2) , 5(R1) :Rc1/4 Piston R: Rc1/8 Note 1 Port size Pilot Rc1/8 Lubrication Not required 0.17〜0.7 {1.7〜7.1} [25〜102] Operating pressure range Main See the table “Minimum Pilot Pressure” MPa {kgf/cm2} [psi.] Pilot 1.05 {10.7} [152] Proof pressure MPa {kgf/cm2} [psi.] 5〜60 [41〜140] Operating temperature range (atmosphere and media) °C[°F] 1373.0 {140.0} Lateral direction Shock 2 m/s {G} resistance Axial direction 912.0{93.0} 264.8{27.0} 912.0{93.0} 264.8{27.0} Mounting direction Any Maximum operating frequency Hz 5 110 [3.88] 135 [4.76] g [oz.] 110 [3.88](300 [10.58])Note 2 135 [4.76](325 [11.46])Note 2 Mass Notes: 1. Port size of sub-base and manifold. 2. Figures in parentheses ( ) are the mass with sub-base. Remarks: For optional specifications and order codes, see p.637〜638. Minimum Pilot Pressure Measurement Conditions MPa {kgf/cm2} [psi.] Main pressure 0.15 {1.5}[22]※ Model 240-4A 240-4A2 ※: Reference value. 0.3{3.1}[44] 0.5{5.1}[73] 0.7{7.1}[102] {4.1}[58] 0.15{1.5}[22] 0.22{2.2}[32] 0.31{3.2}[45] 0.4 {1.0}[15] {0.9}[13] 0.1 {0.7}[10] 0.09 0.06{0.6}[9] 0.07 ●Pilot valve=050-4E1 L (effective area 1.2mm2 ) 〔Cv: 0.07〕 Pilot valve (B port plugged) ●Tube inner diameter 240-4A Time Required for Switching Model Operation 240-4A 240-4A2 ON OFF ON OFF s 2 [6.6] Pilot line length L m [ft.] 6 [19.7] 10 [32.8] 20 [65.6] 50 [164] 100 [328] 0.07 0.15 0.18 0.42 0.32 0.72 0.65 1.50 2.10 4.32 5.80 12.20 0.09 0.23 0.40 0.83 2.73 7.0 =4mm [0.16in.] ●Air pressure (both main and pilot) L =0.5MPa [73psi.] Pilot valve 240-4A2 Manifold Specifications and Port Size Manifold model Specifications 240M□F 1(P), 3(R2), 5(R1) ports manifold piping 4(A), 2(B) ports valve piping 240M□A All port manifold piping 240M□B All port manifold piping Bottom ported Applicable valve model Port size 1(P) 4(A), 2(B) 3(R2), 5(R1) 1(P) 4(A), 2(B) 3(R2), 5(R1) Piston R 1(P) End plate 4(A), 2(B) and 3(R2), 5(R1) side port Piston R 1(P) 4(A), 2(B) Bottom port 3(R2), 5(R1) Rc1/4 Rc1/4 Remarks 240-4A 240-4A2 A240-4A A240-4A2 Piston R becomes pilot R when mounting the solenoid valve. A240-4A A240-4A2 By using port isolators, the 1(P), 4(A), 2(B), 3(R2) and 5(R1) ports can be selected on either the end plate, side piping or bottom piping. Piston R becomes pilot R when mounting the solenoid valve. Rc1/8 Rc1/4 Rc1/8 Rc1/8 For order codes, see p.638. Manifold Mass Manifold model g [oz.] Mass of calculation for each unit (n=number of units) Mounting valve 240-4A2 A240-4A − 135 [4.76] 110 [3.88] − 110 [3.88] − 240-4A A240-4A2 − (68×n)+69 (2.40×n) [ +2.43] 110 [3.88] 240M□F 135 [4.76] − (167×n)+217 (5.89×n) [ +7.65] 240M□A 135 [4.76] − (167×n)+217 (5.89×n) [ +7.65] 240M□B Calculation example: The mass of 240M10F stn.1〜51 240-4A The mass of 240M10F stn.6〜10 240-4A2, (68×10)+69+(110×5)+(135×5)=1974g [69.63oz.]. Block-off plate 30 [1.06] 30 [1.06] Cylinder Operating Speed and Flow Rate 240-4A A240-4A-25 Measurement conditions Measurement conditions ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Piping inner diameter and length: φ7.5×1000mm [39in.] ●Fitting: Quick fitting TS10-02 Load ●Load ratio= (%) Cylinder theoretical thrust ●Air pressure: 0.5MPa {5.1kgf/cm2} [73psi.] ●Piping inner diameter and length: φ7.5×1000mm [39in.] ●Fitting: Quick fitting TS10-02 Load ●Load ratio= (%) Cylinder theoretical thrust ●Cylinder stroke: 300mm [11.8in.] ●Cylinder stroke: 300mm [11.8in.] Load Load Air-piloted valve A240-4A-25 0.5MPa Cylinder Cylinder Air-piloted valve 240-4A 0.5MPa Fitting TS10-02 Fitting TS10-02 Maximum operating speed Maximum operating speed Maximum operating speed 1000 800 φ40 [1.575in.] φ50 [1.969in.] 600 φ63 [2.480in.] 400 φ80 [3.150in.] φ100 [3.937in.] 200 0 10 20 30 40 50 Load ratio 60 Maximum operating speed mm/s 1200 mm/s 1200 1000 800 600 φ40 [1.575in.] φ50 [1.969in.] 400 φ63 [2.480in.] 200 φ80 [3.150in.] φ100 [3.937in.] 0 70 % 10 20 30 40 50 Load ratio 60 70 % 1mm/s=0.0394in./sec. Flow rate MPa Flow rate MPa 0.7 0.6 0.5 0.6 0.4 Valve outlet pressure 0.6 Valve outlet pressure 0.7 0.7 Inlet pressure 0.5 0.3 0.4 0.3 0.2 0.5 0.3 0.2 0.2 0.1 0 0.1 0.1 0 500 1000 Flow rate 1500 2000 R/min(ANR) 1MPa=145psi. 1R/min.=0.0353ft3/min. Inlet 0.7 pressure 0.4 0.6 0.5 0.4 0.3 0.2 0.1 500 1000 Flow rate 1500 2000 R/min(ANR) Operating Principles and Symbols 5-port, 2-position Single pilot Double pilot 240-4A 240-4A2 14(PA) 4(A) 2(B) 14(PA) 4(A) 2(B) 5(R1) 1 (P) 3(R2) 5(R1) 1(P) 3(R2) 12(PB) 240-4A 240-4A2 Pilot connection port Normal condition (Condition with pilot air applied to 12(PB), and then released) Actuated condition Piston 14(PA) Body Piston R 5(R1) 5 (R1) 5(R1) 4(A) 4(A) 4(A) 1(P) 1(P) 1(P) 2(B) 2 (B) 2(B) 3(R2) 3(R2) 3(R2) Lip seal Stem End cover 12(PB) Major Parts and Materials Valve Manifold Parts Materials Body Stem Aluminum alloy (anodized) Lip seal Synthetic rubber Mounting base Mild steel (zinc plated) Sub-base Aluminum alloy (anodized) Body Aluminum alloy (anodized) Block-off plate Mild steel (zinc plated) Seal Synthetic rubber Dimensions of Air-piloted Valves (mm) ●240-4A 23 Rc1/8 Pilot connection port 35 2-Piston R 2-Rc1/8 2-φ3.3 Counterbore R3 Depth 3 Mounting hole 2-φ3.3 Mounting hole 5(R1) 2 36 19.6 3-Rc1/4 2 9 17.5 35.5 1(P) 25.7 22 24.5 40 2(B) 15.5 79.5 4(A) 3(R2) 8 3 9 3 11.5 11.5 2-M3×0.5 Depth 4 Mounting thread 7 7 ●240-4A2 23 35 2-Rc1/8 Pilot connection port 2-Piston R 2-φ3.3 Mounting hole 2-φ3.3 Counterbore R3 Depth 3 Mounting hole 14(PA) 2-Rc1/8 5(R1) 44 3(R2) 26 12(PB) 1(P) 34.2 33 24 2(B) 36 19.6 22 40 88 4(A) 3-Rc1/4 8 2 2 9 9 3 3 Options 108.8 (To the top surface of the valve) 5.6 ●Mounting base: -21 ●Speed controller: -70 35 2-φ4.5 Mounting hole 18 18 46 11.4 B 1.6 (21) 10 Width across flats R1/8 Dimensions of Air-piloted Valves (mm) ●A240-4A-25 ●A240-4A-27 82.5 43 9 23 21 11 38.5 Rc1/8 Pilot connection port 10 43 35 27.5 17.5 21 40 1(P) 10 4.5 5-Rc1/4 34 2-φ4.5 Mounting hole A 30 3(R2) 58.5 79.5 5.5 19.5 2(B) 68.5 21 4(A) 55 PR 5(R1) Rc1/8 Piston R 4.5 ●A240-4A2-25 ●A240-4A2-27 43 9 23 21 82.5 11 38.5 2-Rc1/8 Pilot connection port 10 43 35 27.5 17.5 21 Rc1/8 Piston R 40 1(P) 58.5 88 A 30 3(R2) 19.5 2(B) 68.5 21 4(A) 55 PR 5(R1) 14(PA) 10 14 4.5 12(PB) 5-Rc1/4 2-φ4.5 Mounting hole 34 4.5 〈Viewed from A〉 Options -27: Bottom port ●Speed controller: -70 M5×0.8 Piston R (21) 5(R1) 14 Width across flats 4(A) 23 30 40 18.5 55 1(P) 3(R2) 2(B) 10 R1/4 PR 16.2 5-Rc1/4 10.5 25 34.5 ">
Advertisement
Key features
- Single pilot
- Direct piping
- 2-position
- 5 ports
- Closed center
- Exhaust center (optional)
Frequently asked questions
The operating pressure range for the Koganei 240_4A is 0.17〜0.7 MPa {1.7〜7.1} [25〜102] psi. as viewed in the instructions manual.
The Koganei 240_4A is designed for use with air.
The port sizes are P, A, B: Rc1/4 and R: Rc1/8 as per the document.