Koganei BTAL Single acting non-rotating pull type Instruction manual
Koganei BTAL is a single-acting non-rotating pull type air cylinder. It is designed for use in applications where a compact and reliable solution is required. The cylinder features a robust construction and a variety of mounting options, making it suitable for a wide range of applications.
PDF
Document
Advertisement
Advertisement
BK-UC003 Ver.1.0 Air Cylinder MULTI MOUNT CYLINDER INSTRUCTION MANUAL Ver.1.0 Handling Instructions and Precautions Replacement of mounting brackets Sensor switches ●Rod side mounting bracket Remove the rod end nut, loosen the rod cover (mounting bracket) mounting screws, and remove the rod cover (mounting bracket). Assemble the replacement mounting bracket by reversing the order of procedures for removal. For non-rotating cylinders, loosen the setscrew for plate and remove the plate assembly, and remove the rod cover (mounting bracket). For assembly, align and assemble the guide pin holes of the mounting bracket and the cylinder body, insert the plate assembly, and tighten and secure the setscrew for plate against the piston rod. In this case, retract the piston rod in the fully retracted position at the head side stroke end, maintain a clearance of about 0.5mm [0.020in.] between the plate and rod bushing, and secure the plate assembly in place. Head cover mounting screw Spring Procedure for finding the best sensing position ●Setting the head side stroke end 1. Push piston rod to the fully retracted position. 2. Install a sensor switch in a holder without tightening a mounting screw all the way, move the switch from head side to rod side until it turns ON (for ZC130□, ZC153□ and CS11T□, when the LED lights up), then move the switch 1 notch (= 1mm [0.039in.]) for ZC130□ and ZC153□, or 2 notches (= 2mm [0.079in.]) for CS5T□ and CS11T□ toward the rod side, and tighten the mounting screw. Sensor holder Mounting screw Head cover Rod bushing Setscrew for plate Moving Head cover 1 notch =1mm [0.039in.] Main body Spring holder Rod cover Rod cover mounting screw Plate assembly Rod end nuts The diagram shows a non-rotating single acting push type cylinder. ●Head side mounting bracket Loosen the head cover (mounting bracket) mounting screws and remove the head cover (mounting bracket). Assemble the replacement mounting bracket by reversing the order of procedures for removal. Cautions: 1. To increase the mounting accuracy of the side mounting, assemble so that the rod cover and head cover do not protrude from the cylinder body, and mount so that the cylinder body contacts tightly to the device. 2. Use the supplied mounting screws, or when using commercial screws, use the sizes shown in the table below to secure mounting brackets in place. ●Setting the rod side stroke end Conduct the same procedure as the head side, but on the reversed way. 1. Pull piston rod to the fully extended position. 2. Install a sensor switch in a holder without tightening a mounting screw all the way, move the switch from rod side to head side until it turns ON, then move the switch 1 notch (=1mm [0.039in.]) for ZC130□ and ZC153□, or 2 notches (= 2mm [0.079in.]) for CS5T□ and CS11T□ toward head side, and tighten the mounting screw. ●Caution when installing cylinder with sensor switch Model marking surface Bore size mm [in.] Screw size Length of below head mm [in.] 6 [0.236] M2.6×0.45 6 [0.236] 10 [0.394] M3×0.5 8 [0.315] 16 [0.630] M4×0.7 8 [0.315] Sensing surface 3. Refer to the figures in the table below for the tightening torque of the non-rotating cylinder’s setscrew for plate, and for the size of the Allen wrench used. Bore size mm [in.] Tightening torque N·cm [in·lbf] Hexagonal bar spanner nominal size mm [in.] 6 [0.236] 49 [4.37] 1.27 [0.050] 10 [0.394] 98.1 [8.68] 1.5 [0.059] 16 [0.630] 137.3 [12.2] 2 [0.079] In the ZC type sensor switches, the opposite side from the model marking surface is the sensing surface side. Mount it so that the cylinder magnet comes to the sensing surface side. General precautions Piping Lubrication 1. In applications with high load ratio or high speed, use an externally mounted stopper to prevent direct shock to the cylinder. 2. Use the cylinder body’s 4-M3 × 0.5 female thread only for mounting a sensor switch or shield plate. The product can be used without lubrication, if lubrication is required, use Turbine Oil Class 1 (ISO VG32) or equivalent. Avoid using spindle oil or machine oil. Media Piping Always thoroughly blow off (use compressed air) the tubing before connecting it to the cylinder. Entering chips, sealing tape, rust, etc., generated during piping work could result in air leaks or other defective operation. Atmosphere 1. If using in locations subject to dripping water, dripping oil, etc., or to large amounts of dust, use a cover to protect the unit. 2. The product cannot be used when the media or ambient atmosphere contains any of the substances listed below. Organic solvents, phosphate ester type hydraulic oil, sulphur dioxide, chlorine gas, or acids, etc. 1. Use air for the media. For the use of any other media, consult us. 2. Air used for the cylinder should be clean air that contains no deteriorated compressor oil, etc. Install an air filter (filtration of a minimum 40 µm) near the cylinder or valve to remove collected liquid or dust. In addition, drain the air filter periodically. MULTI MOUNT CYLINDERS Standard Cylinders Symbols ●Double acting type (BDA) ●Single acting push type (BSA) Specifications Bore size mm [in.] 6 [0.236] Item ●Single acting pull type (BTA) ● Double acting double rod type (BDAD) Media pressure range MPa N [lbf.] Pressure Air pressure MPa [psi.] Bore size Piston rod Operation area diameter 2 0.2 0.1 0.3 0.4 0.5 0.6 0.7 mm mm [in.] mm [in.] type [in.2] [15] [29] [44] [58] [73] [87] [102] 28.2 5.6 8.5 11.3 14.1 16.9 19.7 Push side [0.0437] − [1.26] [1.91] [2.54] [3.17] [3.80] [4.43] Double acting type 21.2 4.2 6.4 8.5 10.6 12.7 14.8 Pull side [0.0329] − [0.94] [1.44] [1.91] [2.38] [2.85] [3.33] 6 3 [0.236] [0.118] 28.2 1.7 4.6 7.4 10.2 13 15.8 Single acting push type [0.0437] − [0.38] [1.03] [1.66] [2.29] [2.92] [3.55] 21.2 Single acting pull type [0.0329] Double acting type 10 5 [0.394] [0.197] 16 6 [0.630] [0.236] − − 2.5 4.6 6.7 8.8 10.9 [0.56] [1.03] [1.51] [1.98] [2.45] [psi.] 0.1〜0.7 [15〜102] 0.08〜0.7 [12〜102] Single acting push type 0.2〜0.7 [29〜102] 0.15〜0.7 [22〜102] 0.15〜0.7 [22〜102] Single acting pull type 0.3〜0.7 [44〜102] 0.2〜0.7 [29〜102] 0.2〜0.7 [29〜102] Double acting double rod type 0.2〜0.7 [29〜102] 0.15〜0.7 [22〜102] 0.1〜0.7 [15〜102] Proof pressure 1.03 [149] MPa [psi.] Operating temperature range 0〜60 [32〜140] °C [°F] 50〜500 [2.0〜19.7] Operating speed range mm/s [in./sec.] Rubber bumper Not required Cushion (If lubrication is required, use Turbine Oil Class 1 [ISO VG32] or equivalent.) Lubrication Port size M5×0.8 +1 +0.039 ] 0[ 0 78.5 7.9 15.7 23.6 31.4 39.3 47.1 55 [0.1217] [1.78] [3.53] [5.31] [7.06] [8.83] [10.59] [12.36] Pull side 58.9 5.9 11.8 17.7 23.6 29.5 35.3 41.2 [0.0913] [1.33] [2.65] [3.98] [5.31] [6.63] [7.94] [9.26] Operation Type, Bore Size, and Stroke 7.9 15.8 23.6 31.5 39.3 47.2 − [1.78] [3.55] [5.31] [7.08] [8.83] [10.61] 58.9 Single acting pull type [0.0913] 9.9 15.8 21.7 27.5 33.4 4 − [0.90] [2.23] [3.55] [4.88] [6.18] [7.51] 201 20.1 40.2 60.3 80.4 100.5 120.6 140.7 Push side [0.312] [4.52] [9.04] [13.56] [18.07] [22.59] [27.11] [31.63] Double acting type 172 17.2 34.4 51.6 68.8 86 103.2 120.4 Pull side [0.267] [3.87] [7.73] [11.60] [15.47] [19.33] [23.20] [27.07] 201 Single acting push type [0.312] 18.6 38.7 58.8 78.9 99 119.1 − [4.18] [8.70] [13.22] [17.74] [22.26] [26.77] 172 [0.267] 12.8 30 47.2 64.4 81.6 98.8 − [2.88] [6.74] [10.61] [14.48] [18.34] [22.21] Single acting pull type Stroke mm Standard strokes 10 5, 10, 15, 20, 25, 30 16 6 Single acting push type Single acting pull type 10 5, 10, 15 16 6 Double acting double rod type 10 16 N [lbf.] Zero stroke Bore size 6 Double acting type Spring Return Force (Only for Single Acting Type) Item mm [in.] mm Operation type Note: For the double acting double rod type, see the double acting type pull side. End of stroke 5 10 15 5, 10, 15 2.9 [0.65] 2.5 [0.56] 2.0 [0.45] 3.9 [0.88] 10 [0.394] 6.9 [1.55] 4.9 [1.10] 2.9 [0.65] 7.8 [1.75] 16 [0.630] 17.7 [3.98] 13.7 [3.08] 9.8 [2.20] 21.6 [4.86] 6 [0.236] 0.15〜0.7 [22〜102] Push side 78.5 [0.1217] Bore size mm [in.] Double acting type Stroke tolerance Single acting push type 16 [0.630] Air Operating Cylinder Thrust 10 [0.394] 5, 10, 15, 20, 25, 30 Double acting type Single acting push type Single acting pull type Double acting double rod type Page where dimensions are shown 101 Page where dimensions are shown 104 Page where dimensions are shown 107 Page where dimensions are shown 110 BDA BSA BTA BDAD Mass g [oz.] Mass of side mount Operation Bore size type mm [in.] Double acting type 6 [0.236] 10 [0.394] Single acting pull type Single acting push type 16 [0.630] 6 [0.236] 10 [0.394] 16 [0.630] 6 [0.236] 10 [0.394] 16 [0.630] Stroke mm Standard cylinder Cylinder with magnet 5 21 [0.74] 24 [0.85] 10 24 [0.85] 27 [0.95] 15 27 [0.95] 30 [1.06] 20 30 [1.06] 33 [1.16] 25 33 [1.16] 36 [1.27] 30 36 [1.27] 39 [1.38] 5 37 [1.31] 43 [1.52] 10 41 [1.45] 47 [1.66] 15 45 [1.59] 51 [1.80] 20 49 [1.73] 55 [1.94] 25 53 [1.87] 59 [2.08] 30 57 [2.01] 63 [2.22] 5 79 [2.79] 92 [3.25] 10 86 [3.03] 99 [3.49] 15 93 [3.28] 106 [3.74] 20 100 [3.53] 113 [3.99] 25 107 [3.77] 120 [4.23] 30 114 [4.02] 127 [4.48] 5 25 [0.88] 28 [0.99] 10 28 [0.99] 31 [1.09] 15 31 [1.09] 34 [1.20] 5 43 [1.52] 49 [1.73] 10 47 [1.66] 53 [1.87] 15 51 [1.80] 57 [2.01] 5 90 [3.17] 103 [3.63] 10 97 [3.42] 110 [3.88] 15 104 [3.67] 117 [4.13] 5 27 [0.95] 30 [1.06] 10 30 [1.06] 33 [1.16] 15 33 [1.16] 36 [1.27] 5 46 [1.62] 52 [1.83] 10 50 [1.76] 56 [1.98] 15 54 [1.90] 60 [2.12] 5 100 [3.53] 113 [3.99] 10 107 [3.77] 120 [4.23] 15 114 [4.02] 127 [4.48] Additional mass With 1 sensor switch Double (Only for cylinder with magnet type) rod ZC130□ ZC153□ CS5T□ CS11T□ Rod side mounting bracket Head side mounting bracket Foot A mount Flange A mount Flange B mount Foot A mount Flange A mount Flange B mount 4 [0.14] 20 [0.71] 10 [0.35] 1 [0.04] 1 [0.04] 15 [0.53] 5 [0.18] 5 [0.18] 8 [0.28] 20 [0.71] 16 [0.56] 2 [0.07] 2 [0.07] 24 [0.85] 8 [0.28] 8 [0.28] 16 [0.56] 20 [0.71] 33 [1.16] 4 [0.14] 4 [0.14] 53 [1.87] 17 [0.60] 17 [0.60] − 20 [0.71] 10 [0.35] 1 [0.04] 1 [0.04] 15 [0.53] 5 [0.18] 5 [0.18] − 20 [0.71] 16 [0.56] 2 [0.07] 2 [0.07] 24 [0.85] 8 [0.28] 8 [0.28] − 20 [0.71] 33 [1.16] 4 [0.14] 4 [0.14] 53 [1.87] 17 [0.60] 17 [0.60] − 20 [0.71] 10 [0.35] 1 [0.04] 1 [0.04] 15 [0.53] 5 [0.18] 5 [0.18] − 20 [0.71] 16 [0.56] 2 [0.07] 2 [0.07] 24 [0.85] 8 [0.28] 8 [0.28] − 20 [0.71] 33 [1.16] 4 [0.14] 4 [0.14] 53 [1.87] 17 [0.60] 17 [0.60] Calculation example: To add 2 sensor switches to the cylinder with magnet, double acting type BDAS10×20, 55+(20×2)=95g [3.35oz.] Remark: There are 2 types of sensor switch lead wire lengths. A: 1000mm [39in.], B: 3000mm [118in.] Order Codes for Standard Cylinders ■ Cylinder specification ■ System ■ Mounting type ■ Sensor switch (Made to order) (Rod side) Side mount Blank: Standard specifications NCU: Non-ion specification ●With Blank countermeasure for non generating copper ion Foot A mount ●Made to order Blank: Standard cylinderNote1 S : Cylinder with magnet -1A Flange A mount ■ Number of sensor switches ■ Lead wire length No sensor switch A : 1000mm [39in.] B : 3000mm [118in.] No sensor switch Blank Blank With ZC130 With 1 sensor switch With CS5T -ZC130 -CS5T 1 ●Solid state type ●With indicator lamp ●DC10〜28V ●2-lead wire ●Reed switch type ●Without indicator lamp ●DC5〜28V AC85〜115V With ZC153 With CS11T With 2 sensor switches -3A Flange B mount Note2 -3B BDA Single acting push type BSA Single acting pull type BTA Double acting double rod type BDAD -ZC153 -CS11T ●Solid state type ●With indicator lamp ●DC4.5〜28V ●3-lead wire ●Reed switch type ●With indicator lamp ●DC10〜28V Bore size × Stroke Basic type Double acting type 2 × S Notes: 1. The magnet for the sensor switch is not built-in. Always use the cylinder with magnet when using the sensor switch. 2. Two sensor switches cannot be installed on a cylinder with flange B mount. Mount 1 sensor switch on the head side when the flange B mount is used on the rod side, and mount 1 sensor switch on the rod side when the flange B mount is used on the head side. -1A -3A -3B -NCU -ZC130 -ZC153 -CS5T -CS11T A B 1 2 ● For the order codes of sensor switches only, see p.126. ● In the 5mm [0.197in.] cylinder strokes, 1 sensor switch installation is standard for CS5T and CS11T. When mounting 2 units, use the solid state type. ● For details, see p.1544. ● See table for operation type, bore size and stroke. ● Order the head side mounting bracket separately. Cannot be ordered as already assembled the mount on the cylinder. ● For the order codes of mounting brackets only, see p.125. Remark: For the cylinder joint and cylinder rod end mounted on the piston rod end, see p.1568. ● In the 5mm [0.197in.] cylinder strokes, 1 sensor switch installation is standard for the reed switch type (CS5T, CS11T). Additional Parts (To be ordered separately) Mounting brackets Shield plate Operation Type, Bore Size, and Stroke Operation type Bore size Double acting type 10 Standard strokes 6 5, 10, 15, 20, 25, 30 16 ● Side mount ● Foot A mount ● Flange A (Head cover) mount ● Flange B mount ● The photographs above show head side mounting brackets. ● For the order codes, see p.125. ● Comes with 2 mounting screws. ● For cylinder with magnet. ● For the order code, see p.128. ● Comes with 2 mounting screws. Single acting push type Single acting pull type 10 Double acting double rod type 10 6 5, 10, 15 16 6 16 5, 10, 15, 20, 25, 30 mm Inner Construction and Major Parts ●Double acting type BDA w i r !1 !2 q o ●Single acting push type BSA !5 !7 !3 y e t !4 ●Single acting pull type BTA u ●Cylinder with magnet double acting type BDAS !8 !0 !6 !7 !5 Major Parts and Materials No. ●Double acting double rod type BDAD !9 Parts Materials Standard specification Non-ion specification q q Body Aluminum alloy (anodized) w w Rod cover Note PBT Aluminum alloy (black anodized) e e Head cover Note PBT Aluminum alloy (black anodized) r r Rod bushing Oil impregnated bronze t t Piston rod Stainless steel y y Piston Brass u u Piston seal Synthetic rubber (NBR) i i Rod end nut Steel (electric nickel plated) o o Seal case Brass !0 !0 Cap Polyacetal ← !1 !1 Rod seal Synthetic rubber (NBR) ← !2 !2 O-ring Synthetic rubber (NBR) ← !3 !3 Bumper Synthetic rubber (NBR) ← !4 !4 Spring Steel (zinc plated) !5 !5 Spring holder Brass Aluminum !6 !6 Collar Brass Aluminum !7 !7 Filter Foamed metal !8 !8 Support Brass !9 !9 Magnet ← Special steel ← Aluminum ← ← Special steel ← ← Aluminum φ6: Sintered alloy magnet φ10 ·φ16: Plastic magnet ← Note: Only the foot A mount is steel (black zinc plated). Flange A and flange B mounts are aluminum alloy (black anodized). Seals Parts Bore size mm [in.] Rod seal Piston seal O-ring 6 [0.236] NY-6×3×2 COP-6L 8.4×6×1.2 10 [0.394] NY-8×5×2 COP-10L 10×7.6×1.2 16 [0.630] NY-9×6×2 COP-16L 16×13×1.5 Dimensions of Double Acting Type (mm) ● Side mount BDA Bore size × Stroke BDA- Bore size φV Piston rod diameter N N 1.6 D+Stroke 2-M5×0.8 φ10, φ16 φ10, φ16 A+Stroke B T C+Stroke 1 I G 11 U G R H Q Y S O J K 2-P φL W 4-M3×0.5 (Both sides) Z M+Stroke X φ6 T φ6 10 Type Code R Q 10 S I Standard cylinder Cylinder with magnet A C D M B G H I Bore mm [in.] 6 [0.236] 38 28 8 12 43 33 13 17 10 5 7 5.5 1.8 M3×0.5 10 [0.394] 43 30 7 13 48 35 12 18 13 6 10 7 2.4 M4×0.7 16 [0.630] 48 33 8 15 53 38 13 20 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 25 12 33 20 A C D M J K L Q R S 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 15 7 20 12 8 –0 –0.05 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 18 8 24 14 10.5 5 6 –0 –0.05 N O P T U V 3 6 W 6.5 X Y Z 26 12 16 30 16 17 7.5 33 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Double Acting Type (mm) ● Foot A mount BDA Bore size × Stroke -1A BDA- Bore size MULTI-1A φV Piston rod diameter N N 1.6 D+Stroke 2-M5×0.8 φ6 φ10, φ16 A+Stroke T B T 10 I C+Stroke 1 I U G G H φL K G G AH AH AC AC O 10 J 4-M3×0.5 (Both sides) AF 11+W AG AF 2-φAP AD AA+Stroke AB Standard cylinder Cylinder with magnet Bore mm [in.] A C D AA A C D AA 6 [0.236] 38 28 8 32 43 33 13 10 [0.394] 43 30 7 34 48 35 16 [0.630] 48 33 8 38 53 38 Type Code B G H I J K L N O T 37 10 5 7 5.5 1.8 M3×0.5 6 –0 –0.05 12 39 13 6 10 7 2.4 M4×0.7 10 14 12 13 43 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 8 –0 –0.05 11.5 15 U V 3 14 10.5 5 20 6 W AB AC AD AF AG AH AP 6 26 13 6 9 16 9 31 14 8 10 19 7.5 10 41.5 17 12 12 25 4.5 6.5 3.5 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Double Acting Type (mm) ● Flange A mount BDA Bore size × Stroke -3A BDA- Bore size MULTI-3A φV Piston rod diameter N N 1.6 D+Stroke 2-M5×0.8 φ6 φ10, φ16 A+Stroke T B T 10 I C+Stroke 1 I U G G H BH BH BC BC O 10 J K φL BG BG 4-M3×0.5 (Both sides) 2-φAP AF ● Flange B mount BDA BB 2-φAP AF 11+W Bore size × Stroke -3B BDA- Bore size MULTI-3B φV N N D+Stroke 1.6 Piston rod diameter 2-M5×0.8 φ6 φ10, φ16 A+Stroke B T T 2-φAP 2-φAP C+Stroke 1 I I G U G H O S BI S BI J K BF BF BE Type Code φL BE BB 4-M3×0.5 (Both sides) 11+W Standard cylinder Cylinder with magnet B G H I N O S T 13 10 5 7 5.5 1.8 M3×0.5 6 –0 –0.05 10 14 20 12 35 12 13 6 10 7 2.4 M4×0.7 8 –0 –0.05 11.5 15 24 14 10.5 5 38 13 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 33 20 Bore mm [in.] A C D A C D 6 [0.236] 38 28 8 43 33 10 [0.394] 43 30 7 48 16 [0.630] 48 33 8 53 J K L U V 3 6 W 6.5 AF AP BB BC BE BF BG BH 6 8 3.5 15 27.5 24 18 19 31.5 26 20 7.5 12 4.5 22 42 36 3.5 14 16 28 4.5 21 BI 5 6 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Single Acting Push Type (mm) ● Side mount BSA Bore size × Stroke BSA- Bore size φV Piston rod diameter 0.8 N M5×0.8 φ10, φ16 φ10, φ16 A+Stroke B T C+Stroke 1 I G 11 U G R H Q Y S O J K 2-P φL W 4-M3×0.5 (Both sides) Z M+Stroke X φ6 T φ6 10 Type Code R Q 10 S I Standard cylinder Cylinder with magnet A B G H I Bore mm [in.] 6 [0.236] 43 33 17 48 38 22 10 5 7 5.5 1.8 M3×0.5 10 [0.394] 48 35 18 53 40 23 13 6 10 7 2.4 M4×0.7 16 [0.630] 53 38 20 58 43 25 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 25 12 33 20 C M A C M J K L Q R S 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 15 7 20 12 8 –0 –0.05 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 18 8 24 14 10.5 5 6 –0 –0.05 N O P T U V 3 6 W 6.5 X Y Z 26 12 16 30 16 17 7.5 33 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Single Acting Push Type (mm) ● Foot A mount BSA Bore size × Stroke -1A BSA- Bore size MULTI-1A φV N 0.8 Piston rod diameter M5×0.8 φ6 φ10, φ16 A+Stroke T B T 10 C+Stroke 1 I I U G G H φL K G G AH AH AC AC O 10 J 4-M3×0.5 (Both sides) AF 11+W AG AF 2-φAP AD AA+Stroke AB Type Code Standard cylinder Cylinder with magnet B G H I 42 10 5 7 40 44 13 6 10 43 48 15 7 12 Bore mm [in.] A C AA A C AA 6 [0.236] 43 33 37 48 38 10 [0.394] 48 35 39 53 16 [0.630] 53 38 43 58 J K L N O T 5.5 1.8 M3×0.5 7 2.4 8 3.2 U V 6 –0 –0.05 10 14 12 M4×0.7 8 –0 –0.05 11.5 15 14 10.5 5 M5×0.8 10 –0 –0.05 12.5 19 20 3 6 W AB AC AD AF AG AH AP 6 26 13 6 9 16 9 31 14 8 10 19 7.5 10 41.5 17 12 12 25 4.5 6.5 3.5 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Single Acting Push Type (mm) ● Flange A mount BSA Bore size × Stroke -3A BSA- Bore size MULTI-3A φV Piston rod diameter 0.8 N M5×0.8 φ6 φ10, φ16 A+Stroke T B T 10 C+Stroke 1 I I U G G H BH BH BC BC O 10 J K φL BG BG 4-M3×0.5 (Both sides) 2-φAP AF ● Flange B mount BSA BB 2-φAP AF 11+W Bore size × Stroke -3B BSA- Bore size MULTI-3B N φV 0.8 Piston rod diameter M5×0.8 φ6 φ10, φ16 A+Stroke B T T 2-φAP 2-φAP C+Stroke 1 I I U G G H O S BI S BI J K BF BE Type Code φL BF BB BE 4-M3×0.5 (Both sides) 11+W Standard cylinder Cylinder with magnet B G H I 38 10 5 7 53 40 13 6 10 58 43 15 7 12 Bore mm [in.] A C A C 6 [0.236] 43 33 48 10 [0.394] 48 35 16 [0.630] 53 38 J N O S T 6 –0 –0.05 10 14 20 12 M4×0.7 8 –0 –0.05 11.5 15 24 14 10.5 5 M5×0.8 10 –0 –0.05 12.5 19 33 20 K L 5.5 1.8 M3×0.5 7 2.4 8 3.2 U V 3 6 W 6.5 AF AP BB BC BE BF BG BH 6 8 3.5 15 27.5 24 18 19 31.5 26 20 7.5 12 4.5 22 42 36 3.5 14 16 28 4.5 21 BI 5 6 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Single Acting Pull Type (mm) ● Side mount BTA Bore size × Stroke BTA- Bore size N 0.8 φV Piston rod diameter M5×0.8 φ10, φ16 φ10, φ16 A+ (Stroke×2) C+Stroke B+Stroke T I 1 H G U 11 G R Q Y S O J K φL 2-P W Z 4-M3×0.5 (Both sides) M+Stroke X+Stroke φ6 T φ6 10 R Type Code Q 10 S I Standard cylinder Cylinder with magnet A B G H I Bore mm [in.] 6 [0.236] 43 33 17 48 38 22 10 5 7 5.5 1.8 M3×0.5 10 [0.394] 48 35 18 53 40 23 13 6 10 7 2.4 M4×0.7 16 [0.630] 53 38 20 58 43 25 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 25 12 33 20 C M A C M J K L Q R S 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 15 7 20 12 8 –0 –0.05 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 18 8 24 14 10.5 5 6 –0 –0.05 N O P T U V 3 6 W 6.5 X Y Z 26 12 16 30 16 17 7.5 33 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Single Acting Pull Type (mm) ● Foot A mount BTA Bore size × Stroke -1A BTA- Bore size MULTI-1A N 0.8 φV Piston rod diameter M5×0.8 φ6 φ10, φ16 (Stroke×2) A+ T H I I C+Stroke B+Stroke T 10 1 U G G AC AC O 10 J AH AH φL G K G 4-M3×0.5 (Both sides) AF 11+W AG AF 2-φAP AD AB+Stroke Standard cylinder Cylinder with magnet Bore mm [in.] A C AA A C AA 6 [0.236] 43 33 37 48 38 10 [0.394] 48 35 39 53 16 [0.630] 53 38 43 58 Type Code B G H I 42 10 5 7 40 44 13 6 10 43 48 15 7 12 J K L 5.5 1.8 M3×0.5 7 2.4 8 3.2 AA+Stroke N O T U V 6 –0 –0.05 10 14 12 M4×0.7 8 –0 –0.05 11.5 15 14 10.5 5 M5×0.8 10 –0 –0.05 12.5 19 20 3 6 W AB AC AD AF AG AH AP 6 26 13 6 9 16 9 31 14 8 10 19 7.5 10 41.5 17 12 12 25 4.5 6.5 3.5 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Single Acting Pull Type (mm) ● Flange A mount BTA Bore size × Stroke -3A BTA- Bore size MULTI-3A φV N 0.8 Piston rod diameter M5×0.8 φ6 φ10, φ16 A+ (Stroke× 2 ) T B+Stroke T 10 I C+Stroke H I 1 G U G φL BH BH BC BC O 10 J K 2-φAP AF BG BG 4-M3×0.5 (Both sides) ● Flange B mount BTA BB+Stroke 2-φAP AF 11+W Bore size × Stroke -3B BTA- Bore size MULTI-3B φV N 0.8 Piston rod diameter M5×0.8 φ6 φ10, φ16 A+ (Stroke× 2 ) T 2-φAP 2-φAP C+Stroke B+Stroke T H I 1 G U G I O S BI S BI J φL BF BF BE Type Code K 4-M3×0.5 (Both sides) 11+W BB+Stroke BE Standard cylinder Cylinder with magnet B G H I 38 10 5 7 40 13 6 10 7 Bore mm [in.] A C A C 6 [0.236] 43 33 48 10 [0.394] 48 35 53 16 [0.630] 53 38 58 43 15 7 12 N O S T 6 –0 –0.05 10 14 20 12 M4×0.7 8 –0 –0.05 11.5 15 24 14 10.5 5 M5×0.8 10 –0 –0.05 12.5 19 33 20 K L 5.5 1.8 M3×0.5 2.4 8 J 3.2 U V 3 6 W 6.5 AF AP BB BC BE BF BG BH 6 8 3.5 15 27.5 24 18 19 31.5 26 20 7.5 12 4.5 22 42 36 3.5 14 16 28 4.5 21 BI 5 6 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Double Acting Double Rod Type (mm) ● Side mount BDAD Bore size × Stroke BDAD- Bore size N φV N D+Stroke 1.6 Piston rod diameter 2-M5×0.8 φ6 φ10, φ16 A+ (Stroke× 2 ) T B T 10 1 I I B+Stroke C+Stroke G 11 U G 1 H O Y S S 10 J Y Z K 2-P 4-M3×0.5 (Both sides) φL W M+Stroke Z X Type Code Standard cylinder Cylinder with magnet A C D M B G H I Bore mm [in.] 6 [0.236] 48 28 8 12 53 33 13 17 10 5 7 5.5 1.8 M3×0.5 10 [0.394] 56 30 7 13 61 35 12 18 13 6 10 7 2.4 M4×0.7 16 [0.630] 63 33 8 15 68 38 13 20 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 33 20 A C D M J K L 6 –0 –0.05 N O P S T 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 20 12 U V 3 8 –0 –0.05 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 24 14 10.5 5 6 W 6.5 X 26 12 16 30 16 17 7.5 33 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Double Acting Double Rod Type (mm) ● Foot A mount BDAD Bore size × Stroke -1A BDAD- Bore size MULTI-1A D+Stroke N φV N 1.6 Piston rod diameter 2-M5×0.8 φ6 φ10, φ16 A+ (Stroke× 2 ) T 10 1 I I B+Stroke C+Stroke B T G U G 1 H AH AH AC AC O 10 J G K G 4-M3×0.5 (Both sides) φL AF 11+W AG AF 2-φAP AD (Stroke× 2 ) AA+ AB Standard cylinder Cylinder with magnet Bore mm [in.] A C D AA A C D AA 6 [0.236] 48 28 8 42 53 33 13 10 [0.394] 56 30 7 47 61 35 16 [0.630] 63 33 8 53 68 38 Type Code B G H I J K L N O T 47 10 5 7 5.5 1.8 M3×0.5 6 –0 –0.05 12 52 13 6 10 7 2.4 M4×0.7 10 14 12 13 58 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 8 –0 –0.05 11.5 15 U V 3 14 10.5 5 20 6 W AB AC AD AF AG AH AP 6 26 13 6 9 16 9 31 14 8 10 19 7.5 10 41.5 17 12 12 25 4.5 6.5 3.5 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Double Acting Double Rod Type (mm) ● Flange A mount BDAD Bore size × Stroke -3A BDAD- Bore size MULTI-3A N φV N D+Stroke 1.6 Piston rod diameter 2-M5×0.8 φ6 φ10, φ16 A+ (Stroke× 2 ) T B T 10 1 I I C+Stroke B+Stroke G U G 1 H BH BH BC BC O 10 J K 2-φAP AF BG BG 4-M3×0.5 (Both sides) φL ● Flange B mount BDAD BB 2-φAP AF 11+W Bore size × Stroke -3B BDAD- Bore size MULTI-3B N φV N D+Stroke 1.6 Piston rod diameter 2-M5×0.8 φ6 φ10, φ16 A+ (Stroke× 2 ) B T T 2-φAP 2-φAP C+Stroke 1 I I G B+Stroke U G 1 H O BI S S BI J K BF Type Code BB BF BE 4-M3×0.5 (Both sides) φL 11+W BE Standard cylinder Cylinder with magnet B G H I N O S T 13 10 5 7 5.5 1.8 M3×0.5 6 –0 –0.05 10 14 20 12 35 12 13 6 10 7 2.4 M4×0.7 8 –0 –0.05 11.5 15 24 14 10.5 5 38 13 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 33 20 Bore mm [in.] A C D A C D 6 [0.236] 48 28 8 53 33 10 [0.394] 56 30 7 61 16 [0.630] 63 33 8 68 J K L U V 3 6 W 6.5 AF AP BB BC BE BF BG BH 6 8 3.5 15 27.5 24 18 19 31.5 26 20 7.5 12 4.5 22 42 36 3.5 14 16 28 4.5 21 BI 5 6 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. MULTI MOUNT CYLINDERS Non-rotating Cylinders Symbols ● Double acting type (BDAL) ● Single acting push type (BSAL) Specifications Bore size mm [in.] 6 [0.236] Item ● Single acting pull type (BTAL) ● Double acting double rod type (BDADL) Media 16 [0.630] Air Operating pressure range Cylinder Thrust 10 [0.394] MPa [psi.] Double acting type 0.2〜0.7 [29〜102] 0.15〜0.7 [22〜102] 0.1〜0.7 [15〜102] Single acting push type 0.25〜0.7 [36〜102] 0.2〜0.7 [29〜102] 0.15〜0.7 [22〜102] Single acting pull type 0.35〜0.7 [51〜102] 0.25〜0.7 [36〜102] 0.2〜0.7 [29〜102] Double acting double rod type 0.2〜0.7 [29〜102] 0.15〜0.7 [22〜102] 0.1〜0.7 [15〜102] N [lbf.] Pressure Air pressure MPa [psi.] Operation area mm2 0.1 0.2 0.3 0.4 0.5 0.6 0.7 type [in.2] [15] [29] [44] [58] [73] [87] [102] 28.2 5.6 8.5 11.3 14.1 16.9 19.7 Push side [0.0437] − [1.26] [1.91] [2.54] [3.17] [3.80] [4.43] Double Bore size Piston rod diameter mm [in.] mm [in.] acting type 6 3 [0.236] [0.118] 21.2 [0.0329] 4.2 6.4 8.5 10.6 12.7 14.8 − [0.94] [1.44] [1.91] [2.38] [2.85] [3.33] 28.2 Single acting push type [0.0437] 5.6 8.5 11.3 14.1 16.9 19.7 − [1.26] [1.91] [2.54] [3.17] [3.80] [4.43] Pull side Single acting pull type Double acting type 10 5 [0.394] [0.197] − − 6.4 8.5 10.6 12.7 14.8 [1.44] [1.91] [2.38] [2.85] [3.33] Push side 78.5 7.9 15.7 23.6 31.4 39.3 47.1 55 [0.1217] [1.78] [3.53] [5.31] [7.06] [8.83] [10.59] [12.36] Pull side 58.9 5.9 11.8 17.7 23.6 29.5 35.3 41.2 [0.0913] [1.33] [2.65] [3.98] [5.31] [6.63] [7.94] [9.26] Non-rotating accuracy Stroke tolerance Stroke mm Standard strokes 10 5, 10, 15, 20, 25, 30 16 6 Single acting push type Single acting pull type 10 5, 10, 15 16 6 Double acting double rod type 10 16 End of stroke 5 10 15 5, 10, 15 3.9 [0.88] 2.9 [0.65] 2.0 [0.45] 4.9 [1.10] 10 [0.394] 6.9 [1.55] 4.9 [1.10] 2.9 [0.65] 9.8 [2.20] 16 [0.630] 17.7 [3.98] 13.7 [3.08] 9.8 [2.20] 21.6 [4.86] 6 [0.236] Bore size 6 N [lbf.] Zero stroke +1 +0.039 ] 0 [+ 0 mm [in.] mm Spring Return Force (Only for Single Acting Type) Item ±1° Operation Type, Bore Size, and Stroke 172 17.2 34.4 51.6 68.8 86 103.2 120.4 Pull side [0.267] [3.87] [7.73] [11.60] [15.47] [19.33] [23.20] [27.07] Note: For the double acting double rod type, see the double acting type pull side. ±1.5° M5×0.8 Double acting type Single acting pull type ±2° Port size 201 20.1 40.2 60.3 80.4 100.5 120.6 140.7 Push side [0.312] [4.52] [9.04] [13.56] [18.07] [22.59] [27.11] [31.63] 34.4 51.6 68.8 86 103.2 120.4 − [7.73] [11.60] [15.47] [19.33] [23.20] [27.07] (If lubrication is required, use Turbine Oil Class 1 [ISO VG32] or equivalent.) Lubrication Operation type 172 [0.267] 50〜500 [2.0〜19.7] Rubber bumper Not required 11.8 17.7 23.6 29.5 35.3 41.2 − [2.65] [3.98] [5.31] [6.63] [7.94] [9.26] 40.2 60.3 80.4 100.5 120.6 140.7 − [9.04] [13.56] [18.07] [22.59] [27.11] [31.63] 0〜60 [32〜140] Cushion 58.9 Single acting pull type [0.0913] 201 Single acting push type [0.312] 1.03 [149] °C [°F] Operating speed range mm/s [in./sec.] 15.7 23.6 31.4 39.3 47.1 55 − [3.53] [5.31] [7.06] [8.83] [10.59] [12.36] Bore size mm [in.] MPa [psi.] Operating temperature range 78.5 [0.1217] Single acting push type Double acting type 16 6 [0.630] [0.236] 21.2 [0.0329] Proof pressure 5, 10, 15, 20, 25, 30 Double acting type Single acting push type Single acting pull type Double acting double rod type Page where dimensions are shown 117 Page where dimensions are shown 119 Page where dimensions are shown 121 Page where dimensions are shown 123 BDAL BSAL BTAL BDADL Mass g [oz.] Mass of side mount Operation Bore size type mm [in.] Double acting type 6 [0.236] 10 [0.394] Single acting pull type Single acting push type 16 [0.630] 6 [0.236] 10 [0.394] 16 [0.630] 6 [0.236] 10 [0.394] 16 [0.630] Stroke mm Standard cylinder Cylinder with magnet 5 31 [1.09] 34 [1.20] 10 34 [1.20] 37 [1.31] 15 37 [1.31] 40 [1.41] 20 40 [1.41] 43 [1.52] 25 43 [1.52] 46 [1.62] 30 46 [1.62] 49 [1.73] 5 51 [1.80] 57 [2.01] 10 55 [1.94] 61 [2.15] 15 59 [2.08] 65 [2.29] 20 63 [2.22] 69 [2.43] 25 67 [2.36] 73 [2.57] 30 71 [2.50] 77 [2.72] 5 104 [3.67] 117 [4.13] 10 111 [3.92] 124 [4.37] 15 118 [4.16] 131 [4.62] 20 125 [4.41] 138 [4.87] 25 132 [4.66] 145 [5.11] 30 139 [4.90] 152 [5.36] 5 35 [1.23] 38 [1.34] 10 38 [1.34] 41 [1.45] 15 41 [1.45] 44 [1.55] 5 57 [2.01] 63 [2.22] 10 61 [2.15] 67 [2.36] 15 65 [2.29] 71 [2.50] 5 115 [4.06] 128 [4.51] 10 122 [4.30] 135 [4.76] 15 129 [4.55] 142 [5.01] 5 37 [1.31] 40 [1.41] 10 40 [1.41] 43 [1.52] 15 43 [1.52] 46 [1.62] 5 60 [2.12] 66 [2.33] 10 64 [2.26] 70 [2.47] 15 68 [2.40] 74 [2.61] 5 125 [4.41] 138 [4.87] 10 132 [4.66] 145 [5.11] 15 139 [4.90] 152 [5.36] Additional mass Double rod With 1 sensor switch (including mounting bracket) Rod side mounting bracket Head side mounting bracket Foot A Note Flange A mount ZC130□ ZC153□ CS5T□ CS11T□ mount Flange B mount Foot A mount Flange A mount Flange B mount 4 [0.14] 20 [0.71] 10 [0.35] 1 [0.04] 1 [0.04] 15 [0.53] 5 [0.18] 5 [0.18] 8 [0.28] 20 [0.71] 16 [0.56] 2 [0.07] 2 [0.07] 24 [0.85] 8 [0.28] 8 [0.28] 16 [0.56] 20 [0.71] 33 [1.16] 4 [0.14] 4 [0.14] 53 [1.87] 17 [0.60] 17 [0.60] − 20 [0.71] − 1 [0.04] 1 [0.04] 15 [0.53] 5 [0.18] 5 [0.18] − 20 [0.71] − 2 [0.07] 2 [0.07] 24 [0.85] 8 [0.28] 8 [0.28] − 20 [0.71] − 4 [0.14] 4 [0.14] 53 [1.87] 17 [0.60] 17 [0.60] − 20 [0.71] − 1 [0.04] 1 [0.04] 15 [0.53] 5 [0.18] 5 [0.18] − 20 [0.71] − 2 [0.07] 2 [0.07] 24 [0.85] 8 [0.28] 8 [0.28] − 20 [0.71] − 4 [0.14] 4 [0.14] 53 [1.87] 17 [0.60] 17 [0.60] Note: Can be installed only on the opposite the rod side with the non-rotation plate of a double rod cylinder. Calculation example: To add 2 sensor switches to the cylinder with magnet, double acting type BDALS10×20, 69+(20×2)=109g [3.84oz.] Remark: There are 2 types of sensor switch lead wire lengths. A: 1000mm [39in.], B: 3000mm [118in.] Order Codes for Non-rotating Cylinders ■ Cylinder specification ■ System ■ Mounting type ■ Sensor switch (Made to order) (Rod side) Side mount Blank: Standard specifications NCU: Non-ion specification ●With Blank countermeasure for non generating copper ion Flange A mount ●Made to order Blank: Standard cylinder Note1 S : Cylinder with magnet -3A Flange B mountNote2 ■ Number of Sensor switches ■ Lead wire length No sensor switch A : 1000mm [39in.] B : 3000mm [118in.] No sensor switch Blank Blank With ZC130 With 1 sensor switch With CS5T -ZC130 -CS5T 1 ●Solid state type ●With indicator lamp ●DC10〜28V ●2-lead wire ●Reed switch type ●Without indicator lamp ●DC5〜28V AC85〜115V With ZC153 With CS11T With 2 sensor switches -3B 2 -ZC153 -CS11T ●Solid state type ●With indicator lamp ●DC4.5〜28V ●3-lead wire Bore size × Stroke Basic type Double acting type BDAL Single acting push type BSAL Single acting pull type BTAL Double acting double rod type BDADL ●Reed switch type ●With indicator lamp ●DC10〜28V × S Notes: 1. The magnet for the sensor switch is not built in. Always use the cylinder with magnet when using the sensor switch. 2. Two sensor switches cannot be mounted on a cylinder with flange B mount. Mount 1 sensor switch on the head side when the flange B mount is used on the rod side, and mount 1 sensor switch on the rod side when the flange B mount is used on the head side. -ZC130 -ZC153 -CS5T -CS11T -3A -3B -NCU A B 1 2 ● For the order codes of sensor switches only, see p.126. ● Order the head side mounting bracket ● In the 5mm [0.197in.] separately. cylinder strokes, 1 sensor Cannot be ordered as already assembled switch installation is the mount on the cylinder. standard for CS5T and ● For the order codes of mounting brackets CS11T. When mounting 2 only, see p.125. units, use the solid state Remark: For the cylinder joint and cylinder rod end type. mounted on the piston rod end, see p.1568. ● For details, see p.1544. ● In the 5mm [0.197in.] cylinder strokes, 1 sensor switch is standard for the reed switch type (CS5T, CS11T). ● See table for operation type, bore size and stroke. Additional Parts (To be ordered separately) Mounting brackets Shield plate Operation Type, Bore Size, and Stroke Operation type Bore size Double acting type 10 Standard strokes 6 5, 10, 15, 20, 25, 30 16 ● Side mount ● Foot A mount ● Flange A (Head cover) mount ● Flange B mount ● The photographs above show head side mounting brackets. ● For the order codes, see p.125. ● Comes with 2 mounting screws. ● For cylinder with magnet. ● For the order code, see p.128. ● Comes with 2 mounting screws. Single acting push type Single acting pull type 10 Double acting double rod type 10 6 5, 10, 15 16 6 16 5, 10, 15, 20, 25, 30 mm Inner Construction and Major Parts ●Double acting type BDAL r w i @0 !1 !2 q @1 o ●Single acting push type BSAL !5 !7 !3 y e t !4 ●Single acting pull type BTAL u ●Cylinder with magnet double acting type BDALS !8 !0 !6 Major Parts and Materials !7 !5 No. ●Double acting double rod type BDADL !9 Parts Materials Standard specification Non-ion specification q q Body Aluminum alloy (anodized) ← w w Rod cover Note Aluminum alloy (black anodized) e e Head cover Note PBT ← Aluminum alloy (black anodized) r r Rod bushing Oil impregnated bronze t t Piston rod Stainless steel y y Piston Brass u u Piston seal Synthetic rubber(NBR) i i Rod end nut Steel (electric nickel plated) o o Seal case Brass !0 !0 Cap Polyacetal ← !1 !1 Rod seal Synthetic rubber (NBR) ← !2 !2 O-ring Synthetic rubber (NBR) ← !3 !3 Bumper Urethane rubber ← !4 !4 Spring Steel (zinc plated) !5 !5 Spring holder Brass Aluminum !6 !6 Collar Brass Aluminum !7 !7 Filter Foamed metal !8 !8 Support Brass !9 !9 Magnet @0 @0 Plate Brass (electric nickel plated) @1 @1 Guide pin Stainless steel Special steel ← Aluminum ← ← Special steel ← ← Aluminum φ6: Sintered alloy magnet φ10, φ16: Plastic magnet ← Steel (nickel plated) ← Note: Only the foot A mount is steel (black zinc plated). Seals Parts Bore size mm [in.] Rod seal Piston seal O-ring 6 [0.236] NY-6×3×2 COP-6L 8.4×6×1.2 10 [0.394] NY-8×5×2 COP-10L 10×7.6×1.2 16 [0.630] NY-9×6×2 COP-16L 16×13×1.5 Dimensions of Non-rotating Double Acting Type (mm) ● Side mount BDAL Bore size × Stroke φV BDAL- Bore size N N D+Stroke 1.6 Piston rod diameter 2-M5×0.8 φ10, φ16 φ10, φ16 A+Stroke B T C+Stroke 1 G 6 4-M3×0.5 (Both sides) E I U 11 G R H Q Y XZ CD S O CE J CF CG K 2-P W Z M+Stroke YZ φCP X+Stroke φ6 T φ6 10 I Q XZ CD S 10 CE R φCP CF CG YZ Type Code Bore mm [in.] Standard cylinder Cylinder with magnet A C D M X A C D M B X E G 6 [0.236] 43 28 8 12 27 48 33 13 17 32 15 7.5 5 H I J K L N O P Q R S T 7 5.5 1.8 M3×0.5 6 –0 –0.05 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 15 7 20 12 U V W Y 3 10 [0.394] 48 30 7 13 31 53 35 12 18 36 18 10.5 6 10 7 2.4 M4×0.7 8 –0 –0.05 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 18 8 24 14 10.5 5 16 [0.630] 53 33 8 15 35 58 38 13 20 40 20 12.5 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 25 12 33 20 Code Bore mm [in.] CD CE CF CG CP XZ YZ 6 [0.236] 7.5 7.5 3.5 5.5 2.5 9.5 11 10 [0.394] 9 8.5 4 6.5 3 11.5 13 16 [0.630] 12.5 9 6 9.5 4 16 19 6.5 Z 12 16 16 17 6 7.5 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Non-rotating Double Acting Type (mm) ● Flange A mount BDAL Bore size × Stroke -3A BDAL- Bore size MULTI-3A φV Piston rod diameter N D+Stroke 1.6 N 2-M5×0.8 φ6 φ10, φ16 A+Stroke T B T 10 I C+Stroke E I 1 G G U H XZ BC BH BH XZ BC O 10 J K BG BG 11+W 2-φAP AF YZ BB YZ ● Flange B mount BDAL 4-M3×0.5 (Both sides) 6 2-φAP AF Bore size × Stroke -3B BDAL- Bore size MULTI-3B φV N N D+Stroke 1.6 Piston rod diameter 2-M5×0.8 φ6 φ10, φ16 A+Stroke B T T 2-φAP 2-φAP C+Stroke 1 E I I G U G H O S BI XZ XZ S BI J YZ YZ BF BE Type Code K BF 6 BE BB 4-M3×0.5 (Both sides) 11+W Standard cylinder Cylinder with magnet N O S T D A G H I 6 [0.236] 43 28 8 48 33 13 15 7.5 5 7 5.5 1.8 M3×0.5 10 [0.394] 48 30 7 53 35 12 18 10.5 6 10 7 2.4 M4×0.7 16 [0.630] 53 33 8 58 38 13 20 12.5 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 33 20 D J L C C B K A E Bore mm [in.] 6 –0 –0.05 10 14 20 12 U V 3 8 –0 –0.05 11.5 15 24 14 10.5 5 6 W AF AP BB BC BE BF BG BH BI XZ YZ 6.5 6 8 3.5 20 27.5 24 18 24 31.5 26 20 3.5 14 16 7.5 12 4.5 27 42 36 28 4.5 21 5 6 9.5 11 11.5 13 16 19 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Non-rotating Single Acting Push Type (mm) ● Side mount BSAL Bore size × Stroke BSAL- Bore size φV N 0.8 Piston rod diameter M5×0.8 φ10, φ16 φ10, φ16 A+Stroke B T C+Stroke 1 G 6 4-M3×0.5 (Both sides) E I U 11 G R H Q Y XZ CD S O CE J φCP CF CG K W 2-P Z M+Stroke YZ X+Stroke φ6 T φ6 10 I Q XZ CD S 10 CE R φCP CF CG YZ Type Code Standard cylinder Cylinder with magnet A E G Bore mm [in.] 6 [0.236] 48 33 17 32 53 38 22 37 15 7.5 C X M A C M X B H I J K N O P Q R S T U V 5 7 5.5 1.8 M3×0.5 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 15 7 20 12 10 [0.394] 53 35 18 36 58 40 23 41 18 10.5 6 10 7 2.4 M4×0.7 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 18 8 24 14 10.5 5 16 [0.630] 58 38 20 40 63 43 25 45 20 12.5 7 12 8 3.2 M5×0.8 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 25 12 33 20 Code Bore mm [in.] CD CE CF CG CP XZ YZ 6 [0.236] 7.5 7.5 3.5 5.5 2.5 9.5 11 10 [0.394] 9 8.5 4 6.5 3 11.5 13 16 [0.630] 12.5 9 6 9.5 4 16 19 3 6 W 6.5 Y Z 12 16 16 17 7.5 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Non-rotating Single Acting Push Type (mm) ● Flange A mount BSAL Bore size × Stroke -3A BSAL- Bore size MULTI-3A φV Piston rod diameter 0.8 N M5×0.8 φ6 φ10, φ16 A+Stroke T B T 10 I C+Stroke E I 1 G G U H XZ BC BH BH XZ BC O 10 J K BG BG 11+W 2-φAP AF YZ AF BB YZ ● Flange B mount BSAL 4-M3×0.5 (Both sides) 6 2-φAP Bore size × Stroke -3B BSAL- Bore size MULTI-3B φV N 0.8 Piston rod diameter M5×0.8 φ6 φ10, φ16 A+Stroke B T T 2-φAP 2-φAP C+Stroke 1 E I I U G G H O S BI XZ XZ S BI J YZ YZ BF BE Type Code K BF 6 BE BB 11+W 4-M3×0.5 (Both sides) Standard cylinder Cylinder with magnet Bore mm [in.] A C A C 6 [0.236] B E G H I J K N O S T U V 48 33 53 38 15 7.5 5 7 5.5 1.8 M3×0.5 10 14 20 12 10 [0.394] 53 35 58 40 18 10.5 6 10 7 2.4 M4×0.7 11.5 15 24 14 10.5 5 3 16 [0.630] 58 38 63 43 20 12.5 7 12 8 3.2 M5×0.8 12.5 19 33 20 6 W 6.5 AF AP BB BC BE BF BG BH 6 8 3.5 20 27.5 24 18 24 31.5 26 20 7.5 12 4.5 27 42 36 3.5 14 16 28 4.5 21 BI 5 6 XZ YZ 9.5 11 11.5 13 16 19 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Non-rotating Single Acting Pull Type (mm) ● Side mount BTAL Bore size × Stroke BTAL- Bore size φV Piston rod diameter 0.8 N M5×0.8 φ10, φ16 φ10, φ16 (Stroke×2) A+ C+Stroke B+Stroke T 1 E I G U 11 G R H Q Y XZ CD S O CE J CF CG 6 K 4-M3×0.5 (Both sides) φL W 2-P M+Stroke YZ φCP Z X+ (Stroke×2) φ6 T φ6 10 I φCP Q XZ CD S 10 CE R CF CG YZ Type Code Standard cylinder Cylinder with magnet A E G Bore mm [in.] 6 [0.236] 48 33 17 32 53 38 22 37 15 7.5 C X M A C M X B H I J K L N O P Q R S T U V 5 7 5.5 1.8 M3×0.5 6 –0 –0.05 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 15 7 20 12 10 [0.394] 53 35 18 36 58 40 23 41 18 10.5 6 10 7 2.4 M4×0.7 8 –0 –0.05 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 18 8 24 14 10.5 5 16 [0.630] 58 38 20 40 63 43 25 45 20 12.5 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 25 12 33 20 Code Bore mm [in.] CD CE CF CG CP XZ YZ 6 [0.236] 7.5 7.5 3.5 5.5 2.5 9.5 11 10 [0.394] 9 8.5 4 6.5 3 11.5 13 16 [0.630] 12.5 9 6 9.5 4 16 19 3 6 W 6.5 Y Z 12 16 16 17 7.5 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Non-rotating Single Acting Pull Type (mm) ● Flange A mount BTAL Bore size × Stroke -3A BTAL- Bore size MULTI-3A φV Piston rod diameter 0.8 N M5×0.8 φ6 φ10, φ16 A+ (Stroke×2) T B+Stroke T 10 I C+Stroke E I 1 G G U H XZ BC BH BH XZ BC O 10 J 2-φAP AF BG BG K YZ 2-φAP AF φL 6 ● Flange B mount BTAL 11+W BB+Stroke YZ 4-M3×0.5 (Both sides) Bore size × Stroke -3B BTAL- Bore size MULTI-3B φV N 0.8 Piston rod diameter M5×0.8 φ6 φ10, φ16 (Stroke×2) A+ T 2-φAP 2-φAP C+Stroke B+Stroke T E I I 1 G U G H O S BI XZ XZ S BI J YZ YZ BF BE Type Code K 11+W φL 6 BF BB+Stroke BE 4-M3×0.5 (Both sides) Standard cylinder Cylinder with magnet A E G H I Bore mm [in.] 6 [0.236] 48 33 53 38 15 7.5 5 7 5.5 1.8 M3×0.5 10 [0.394] 53 35 58 40 18 10.5 6 10 7 2.4 M4×0.7 16 [0.630] 58 38 63 43 20 12.5 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 33 20 C A C B J K L N O S T 6 –0 –0.05 10 14 20 12 U V 3 8 –0 –0.05 11.5 15 24 14 10.5 5 6 W AF AP BB BC BE BF BG BH BI XZ YZ 6.5 6 8 3.5 20 27.5 24 18 24 31.5 26 20 3.5 14 16 7.5 12 4.5 27 42 36 28 4.5 21 5 6 9.5 11 11.5 13 16 19 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Non-rotating Double Acting Double Rod Type (mm) ● Side mount BDADL Bore size × Stroke BDAL- Bore size N φV Piston rod diameter N 1.6 D+Stroke 2-M5×0.8 φ10, φ16 φ10, φ16 (Stroke× 2) A+ B T F+Stroke C+Stroke 1 E I U G 11 G 1 R H Q Y XZ CD S O CE J φCP CF CG 4-M3×0.5 (Both sides) 6 K W φL 2-P Z M+Stroke YZ X+Stroke φ6 T φ6 10 I Q XZ CD S 10 CE R φCP CF CG YZ Type Code Bore mm [in.] Standard cylinder Cylinder with magnet A A C D M X C D M B X E F G 6 [0.236] 53 28 8 12 27 58 33 13 17 32 15 7.5 10 5 H I J K L N O P Q R S T 7 5.5 1.8 M3×0.5 6 –0 –0.05 10 14 φ3.5 Counterboreφ6 Depth4.2 (Both sides) 15 7 20 12 U V W Y 3 10 [0.394] 61 30 7 13 31 66 35 12 18 36 18 10.5 13 6 10 7 2.4 M4×0.7 8 –0 –0.05 11.5 15 φ3.5 Counterboreφ6 Depth3.2 (Both sides) 18 8 24 14 10.5 5 16 [0.630] 68 33 8 15 35 73 38 13 20 40 20 12.5 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 φ4.5 Counterboreφ7.6 Depth4.2 (Both sides) 25 12 33 20 Code Bore mm [in.] CD CE CF CG CP XZ YZ 6 [0.236] 7.5 7.5 3.5 5.5 2.5 9.5 11 10 [0.394] 9 8.5 4 6.5 3 11.5 13 16 [0.630] 12.5 9 6 9.5 4 16 19 6.5 Z 12 16 16 17 6 7.5 24 18 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. Dimensions of Non-rotating Double Acting Double Rod Type (mm) ● Flange A mount BDADL Bore size × Stroke -3A BDADL- Bore size MULTI-3A N D+Stroke φV Piston rod diameter 1.6 N 2-M5×0.8 φ6 φ10, φ16 A+(Stroke×2) T B T 10 I F+Stroke C+Stroke E I 1 G U G 1 H XZ BC BH BH XZ BC O 10 J φL 2-φAP AF BG BG K YZ ● Flange B mount BDADL 11+W 4-M3×0.5 (Both sides) 6 2-φAP AF BB YZ Bore size × Stroke -3B BDADL- Bore size MULTI-3B N N D+Stroke 1.6 φV Piston rod diameter 2-M5×0.8 φ6 φ10, φ16 A+(Stroke×2) B T T 2-φAP 2-φAP I F+Stroke C+Stroke E I 1 G G U 1 H O S BI XZ XZ S BI J YZ YZ BF BE Type K φL BB BE Standard cylinder Cylinder with magnet E I J K A C D A F G H Bore mm [in.] 6 [0.236] 53 28 8 58 33 13 15 7.5 10 5 7 5.5 1.8 M3×0.5 10 [0.394] 61 30 7 66 35 12 18 10.5 13 6 10 7 2.4 M4×0.7 16 [0.630] 68 33 8 73 38 13 20 12.5 15 7 12 8 3.2 M5×0.8 10 –0 –0.05 12.5 19 33 20 Code 11+W 4-M3×0.5 (Both sides) 6 BF C D B L N O S T 6 –0 –0.05 10 14 20 12 U V 3 8 –0 –0.05 11.5 15 24 14 10.5 5 W AF AP BB BC BE BF BG BH BI XY YZ 6.5 6 8 3.5 20 27.5 24 18 24 31.5 26 20 3.5 14 16 6 7.5 12 4.5 27 42 36 28 4.5 21 5 6 9.5 11 11.5 13 16 19 Note: The 4-M3 × 0.5 female thread (for sensor switch mounting) in the drawing should not be used for mounting the cylinder. Moreover, it is not available in the cylinder body of a standard 5mm [0.197in.] stroke cylinder. MOUNTING BRACKETS Rod Side Mounting Bracket, Head Side Mounting Bracket Mounting Bracket Model (Order Codes) Head side Rod side Mounting location ●How to read the codes Bor Mounting es ize brackets mm [in. ] Cylinder model Side mount Foot A mount 6 [0.236] DB60A DB61A DB63A DB63B 10 [0.394] D100A D101A D103A D103B 16 [0.630] D160A D161A D163A D163B 6 [0.236] LB60A − LB63A LB63B 10 [0.394] L100A − L103A L103B 16 [0.630] L160A − L163A L163B 6 [0.236] BB60A BB61A BB63A BB63B All types except 10 [0.394] double rod type 16 [0.630] B100A B101A B103A B103B B160A B161A B163A B163B BDA□ BSA□ BTA□ BDAD□ BDAL□ BSAL□ BTAL□ BDADL□ Flange A mount Flange B mount Mount type 0A Side mount 1A Foot A mount 3A Flange A mount 3B Flange B mount Bore size B6 φ6 [0.236in.] 10 φ10 [0.394in.] 16 φ16 [0.630in.] Applicable cylinder D — BDA □, BSA □, BTA □, and BDAD □ (for rod side) L — BDAL □, BSAL □, BTAL □, and BDADL □ (for rod side) B — All types except double rod type (for head side) Remarks: 1. All mounting brackets come with 2 mounting screws. 2. Order separately for all head side mounting brackets. 3. For the order codes of rod side mounting brackets assembled with cylinders, see p.99 and 115. 4. No rod side foot A mount for the non-rotating cylinder is available. For non-rotating double rod cylinders, however, a separately ordered foot A mount can be installed on the rod side opposite the non-rotation plate. 5. A rod bushing is assembled into the rod side mounting bracket. Dimensions of Head Side Mounting Bracket (mm) Flange A mount: -3A MULTI-1A ●φ6 T ●φ6 T 10 G R BH BC 10 R BG G AG T G φBJ AC 10 Q BH φBJ BE 10 Q R BH AF AI AF ●φ10,16 2-φAP ●φ10,16 ●φ10,16 BE T T G R BH 2-φAP BF 2-φAP AD G MULTI-3B φBJ G Q ●φ6 Flange B mount: -3B MULTI-3A S Foot A mount: -1A R R BH AG AF AI AF Code G Q S Q BF 2-φAP 2-φAP AD Bore size mm [in.] φBJ BC Q G BG AC φBJ Q φBJ BH T G R S T AC AD AF 2-φAP AG AI AP BC BE BF BG BH BJ 2 +0.05 0 2 +0.05 0 2 +0.05 0 8 +0.1 0 6 [0.236] 5 15 7 20 12 26 13 6 9 4 3.5 27.5 24 18 3.5 10 [0.394] 6 18 8 24 14 31 14 8 10 4 3.5 31.5 26 20 3.5 16 [0.630] 7 25 12 33 20 41.5 17 12 12 5 4.5 42 36 28 4.5 Remark: For the side mount (head cover), see the cylinder dimensions. 12 +0.1 0 18 +0.1 0 SENSOR SWITCHES Solid State Type, Reed Switch Type Order Codes (for Sensor Switches Only) Sensor switches Solid state type DC10〜28V with indicator lamp Solid state type DC4.5〜28V with indicator lamp Option Lead wire length With sensor holder ZC130 ZC153 Reed switch type DC5〜28V without indicator lamp AC85〜115V CS5T Reed switch type DC10〜28V with indicator lamp CS11T A B -BDAS6 -BDAS10 -BDAS16 Moving Sensor Switch ● Loosening mounting screw allows the sensor switch to be moved freely in the cylinder’s axial direction. ● Tighten the mounting screw with a tightening torque of 19.6N·cm [1.73in·lbf] or less. ●φ6 Mounting screw Sensor switch Sensor holder ●A :1000mm [39in.] ●B :3000mm [118in.] ★ Order codes of sensor holders only Forφ6 cylinder — C1-BDAS6 ●-BDAS6 : For φ 6 cylinder Forφ10 cylinder — C1-BDAS10 ●-BDAS10 : For φ 10 cylinder Forφ16 cylinder — C1-BDAS16 ●-BDAS16 : For φ 16 cylinder ● For sensor switch details, see p.1544. ●φ10,16 Mounting screw Sensor switch Sensor holder Minimum Cylinder Strokes When Using Sensor Switches mm [in.] Bore size Solid state type sensor switch Reed switch type sensor switch Mounting 2 pcs. Mounting 1 pc. Mounting 2 pcs. Mounting 1 pc. 6 [0.236] 10 [0.394] 5 5 10 5 16 [0.630] Remark: Two sensor switches cannot be mounted on a cylinder with flange B mount. Mount 1 sensor switch on the head side when the flange B mount is used on the rod side, and mount 1 sensor switch on the rod side when the flange B mount is used on the head side. Sensor Switch Operating Range, Response Differential, and Maximum Sensing Location ● Operating range: R The distance the piston travels in one direction, while the switch is in the ON position. ● Response differential: C The distance between the point where the piston turns the switch ON, and the point where the switch is turned OFF as the piston travels in the opposite direction. mm [in.] Bore size Sensor switch Magnet R CS5T□,CS11T□ ZC130□,ZC153□ Operating range Response differential Operating range Response differential 6 [0.236] 2.0〜3.0 [0.079〜0.118] 0.3 [0.012] or less 4.8〜7.2 [0.189〜0.283] 1.3 [0.051] or less 10 [0.394] 2.0〜3.0 [0.079〜0.118] 0.3 [0.012] or less 5.8〜8.3 [0.228〜0.327] 2.0 [0.079] or less 16 [0.630] 2.5〜4.0 [0.098〜0.157] 0.3 [0.012] or less 7.5〜9.4 [0.295〜0.370] 2.5 [0.098] or less C (Response differential) ON OFF R ON OFF C (Response differential) Maximum sensing location Remark: The above table shows reference values. Mounting Location of End of Stroke Detection Sensor Switch ●Cylinder with magnet ●Double rod cylinder with magnet Connection port Y ●Non-rotating cylinder with magnet ●Non-rotating double rod cylinder X Sensor switch model marking 7.5 Y X ■Double acting type (Including double rod cylinders) Bore size 7.5 mm [in.] Sensor switch model Mounting location ZC130□, ZC153□ CS11T□ Bore size Mounting location mm [in.] Sensor switch model ZC130□,ZC153□ CS5T□ CS11T□ 6 [0.236] X 13.0 [0.512] 11.5 [0.453] 15 [0.591] 6 [0.236] X 6.0 [0.236] 4.5 [0.177] 8 [0.315] 10 [0.394] Y 8.0 [0.315] 6.5 [0.256] 10 [0.394] 10 [0.394] Y 1.0 [0.039] −0.5 [−0.020] 3 [0.118] X 14.0 [0.551] 12.5 [0.492] 16 [0.630] X 7.0 [0.276] 5.5 [0.217] 9 [0.354] Y 9.0 [0.354] 7.5 [0.295] 11 [0.433] Y 2.0 [0.079] 0.5 [0.020] 4 [0.157] 16 [0.630] CS5T□ ■Double acting type (Including double rod cylinders) ■Single acting push type mm [in.] 16 [0.630] ■Single acting push type mm [in.] Sensor switch model Mounting Bore size location ZC130□, ZC153□ CS5T□ CS11T□ Sensor switch model Mounting Bore size location ZC130□, ZC153□ CS5T□ 6 [0.236] X 8.0 [0.315] 6.5 [0.256] 10 [0.394] 6 [0.236] X 1.0 [0.039] −0.5 [−0.020] 3 [0.118] 10 [0.394] Y 8.0 [0.315] 6.5 [0.256] 10 [0.394] 10 [0.394] Y 1.0 [0.039] −0.5 [−0.020] 3 [0.118] X 9.0 [0.354] 7.5 [0.295] 11 [0.433] X 2.0 [0.079] 0.5 [0.020] 4 [0.157] Y 9.0 [0.354] 7.5 [0.295] 11 [0.433] Y 2.0 [0.079] 0.5 [0.020] 4 [0.157] 16 [0.630] ■Single acting pull type mm [in.] Sensor switch model Mounting Bore size location ZC130□, ZC153□ CS5T□ 6 [0.236] X 13.0 [0.512] 11.5 [0.453] 10 [0.394] Y 13.0 [0.512] X Y 16 [0.630] 16 [0.630] ■Single acting pull type CS11T□ mm [in.] CS11T□ Sensor switch model Mounting Bore size location ZC130□, ZC153□ CS5T□ CS11T□ 15 [0.591] 6 [0.236] X 6.0 [0.236] 11.5 [0.453] 8 [0.315] 11.5 [0.453] 15 [0.591] 10 [0.394] Y 6.0 [0.236] 11.5 [0.453] 8 [0.315] 14.0 [0.551] 12.5 [0.492] 16 [0.630] X 7.0 [0.276] 12.5 [0.492] 9 [0.354] 14.0 [0.551] 12.5 [0.492] 16 [0.630] Y 7.0 [0.276] 12.5 [0.492] 9 [0.354] 16 [0.630] Remarks: 1. The above tables give reference values for the standard strokes. For the procedure to find-out the best position, see p.129. 2. The above figures show the piping connection port when it has been turned to face upward. 3. Use the distance between the cylinder mounting hole and the rod cover to confirm the mounting location of the double rod cylinder’s end of stroke detection sensor switch. 4. Mount the sensor switch so that the surface showing the sensor switch model marking faces up. Dimensions of Sensor Switch Mounting (mm) ●φ6 MULTI-SW ●φ10 20 7.5 7.5 5.5 4.5 1 5.5 33 35 1 10.5 24 26 10 12.5 12.5 14.5 1 20 1 22 1 10 14 6.5 1 12 ●φ16 15.5 17.5 Precautions for Mounting Cylinders with Magnet When mounting 2 or more Multi Mount Cylinders with sensor switches in close proximity, use the conditions shown to the right. With shield plate Without shield plate R R R Bore size mm [in.] Shield plate Shield plate 6 [0.236] 25mm [0.984] or longer 23mm [0.906] or longer 22mm [0.866] or longer 10 [0.394] 29mm [1.142] or longer 31mm [1.220] or longer 25mm [0.984] or longer 16 [0.630] 35mm [1.378] or longer 39mm [1.535] or longer 31mm [1.220] or longer Remark: Aside from the above, there are no particular restrictions on mounting. Shield Plate Type (Order Codes) R Ope Applicable shield plate type ratio Str oke n type Double acting type, Double acting double rod type Single acting push/pull type m Bore m 5, 10, 15 20, 25, 30 5, 10 15 size mm [in.] 6 [0.236] BS061 BS062 BS061 BS062 10 [0.394] BS101 BS102 BS101 BS102 16 [0.630] BS161 BS162 BS161 BS162 Remarks: 1. All shield plates come with 2 mounting screws. 2. Order all shield plates separately. MULTI-SE ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- Single-acting pull type
- Non-rotating
- Compact design
- Various mounting options
- Robust construction
- Air pressure operation
- Maximum operating pressure 0.7 MPa (102 psi)
- Operating temperature range 0°C to 60°C (32°F to 140°F)
Frequently asked questions
The maximum operating pressure for the Koganei BTAL air cylinder is 0.7 MPa (102 psi).
The operating temperature range for the Koganei BTAL air cylinder is 0°C to 60°C (32°F to 140°F).
The Koganei BTAL air cylinder can be used without lubrication. If lubrication is required, Turbine Oil Class 1 (ISO VG32) or equivalent should be used. Avoid using spindle oil or machine oil.