Koganei DTY-ELG41 Ionizer gun type Instruction manual
The Koganei DTY-ELG41 is a high-voltage air blower designed for static charge elimination. It utilizes a high-frequency corona discharge method to neutralize static charges effectively. The device can be used in various applications, such as manufacturing processes, where static electricity can cause production issues or hazards. The DTY-ELG41 features adjustable pulse frequency and comes with a range of accessories, including a nozzle, a discharge needle, and an AC adapter.
PDF
Download
Document
Advertisement
Advertisement
Owner's Manual Air Gun Type Ionizer [DTY-ELG41] Thank you for purchasing the DTY-ELG41. This product is not specified to electric equipment standards as a high-voltage device, but it does handle high AC voltages of approximately 2,500 V or more. Please be sure to read this instruction manual before using the product, so that you can fully understand its functions. In addition, keep this manual in a safe place. 1. Safety precautions High voltages are used inside this product, such that incorrect usage could lead to personal injury or damage to the product. Koganei bears no responsibility if the product is used outside its specifications or if the safety precautions are not observed. Expresses situations that can be clearly predicted as dangerous. If the noted danger is not avoided, it could result in death or serious injury. DANGER It could also result in damage or destruction of assets. Expresses situations that, while not immediately dangerous, could become dangerous. If the noted danger is not avoided, it could result in WARNING death or serious injury. It could also result in damage or destruction of assets. Expresses situations that, while not immediately dangerous, could become dangerous. If the noted danger is not avoided, it could result in CAUTION light or semi-serious injury. It could also result in damage or destruction of assets. While there is little chance of injury, this content refers to points that ATTENTION should be observed for appropriate use of the product. 1.1 3. Static charge elimination characteristics Air pressure [MPa] 0.1 0.2 0.3 0.4 0.5 0.6 +Static charge elimination time [seconds] -Static charge elimination time [seconds] Flow rate [L/m (A.N.R.)] (DTY-ELG41-PAU) 0.3 0.3 99 0.2 0.2 159 0.3 0.3 215 0.2 0.2 266 0.2 0.2 320 0.1 0.1 370 Air pressure [MPa] 0.2 0.3 0.4 0.5 0.6 +Static charge elimination time [seconds] 0.6 0.4 0.4 0.3 0.3 -Static charge elimination time [seconds] 0.6 0.4 0.4 0.3 0.3 Flow rate [L/m (A.N.R.)] 56 79 102 113 118 (*Under Koganei measurement conditions) * Measurement distance : 50 mm * Measuring device : Charged plate monitor (plate size 150 mm x 150 mm, electrostatic capacitance 20 pF) * Static charge elimination time : Attenuation time from ±1000 V to 100 V * Φ6 air fitting, Φ6 air tube Names of parts Warning 1.3 Suspension bracket Weight Pulse blow Amount of ozone generated Material *Under Koganei measurement conditions. WARNING Switch for LED lighting Nozzle LED lighting Indicator LED CAUTION ● Do not install the product where it could be splashed by water or oil; locations where condensation forms easily; or locations exposed to severe changes in temperature or humidity. Doing so could damage the product. ● Be sure to use the dedicated AC adaptor. Otherwise, the product could break down, its functions could stop, or it could be damaged. ● Use clean air, from which oil and moisture have been removed, as the medium. Using air that contains water or oil could result in the nozzle and interior of the main unit becoming dirty, the static discharge performance falling, or the main unit deteriorating. ● Do not attach conductive or static dissipative stickers or labels to the tip of the main unit, as the label may become charged due to induction. If you do so, please use an insulating material. Label prohibited area Lever Trimmer to adjust frequency of pulse blow*2 Cover Power cable (2 m) Φ6 air fitting*1 [When gun shaped DTY-ELG41-PAU] Lever Cover Installation Hold the product in your hand and use it the same way as a regular air gun. Also, the main unit can be hung by its suspension bracket. The suspension bracket can be moved for hanging while either straight or gun-shaped. Change the position of the suspension bracket according to your application. Lock button Nozzle Φ6 air fitting*1 To remove the suspension bracket, pull it open from both sides as shown in figure 1. Attention Suspension bracket LED lighting Trimmer to adjust frequency of pulse blow*2 Suspension bracket Suspension bracket [When straight] Switch for LED lighting 2. Contents of the product set Indicator LED [When straight DTY-ELG41-PAU] When you receive this product, before you use it, check whether there are any missing items, and whether there were any abnormalities or damages that occurred during shipping. If there are damages, or if the product does not operate normally, contact your retailer (agent) or our nearest sales office. · Main unit…1, · Nozzle*…1, · Discharge needle*…1, · AC adaptor…1, · Owner’s Manual (this manual)…1 *The main unit is installed when shipped. Air flow rate Dimensions of main unit (excluding protrusions) ● Always supply air to the product whenever it is turned on. Furthermore, when using the product adjust the air flow rate to be 60 ℓ/min (ANR) or more. ● Do not remove and replace the air fitting on the main unit. Doing so could result in damage to the main unit. Caution Equipment and parts used near the ionizer (especially ones with low ozone resistance such as NBR) should be checked periodically for ozone degradation. When the product can no longer be used or is no longer necessary, dispose of the consumables appropriately as industrial waste. Do not wire parallel to power lines or high-voltage lines. Inductive noise could cause erratic operation. *Regarding dangers, warnings, and cautions not noted above, refer to the “Safety Precautions (Common to All Ionizers) and Handling Instructions and Precautions (Common Precautions)” in the Static Electricity Removal Unit Ionizers catalog. (Be sure to refer to the most recent catalog.) Product input voltage Consumption current Output voltage Ion balance Medium used Operating air pressure range DTY-ELG41 DTY-ELG41-PAU High-frequency corona discharge Provided AC adaptor INPUT: AC100 - 240 V, 50/60 Hz, 0.3 A (OUTPUT: DC 24 V, 0.5 A) DC24 V ± 5% Less than 100 mA 2,500V ±15V * Air (clean air that contains no moisture or oil) 0.05 - 0.6MPa 0.2 - 0.6MPa Maximum pulse flow rate 120 Maximum 370 ℓ/min (ANR) ℓ/min (ANR) Gun-shaped: 177.3 (L)×32 (W)×127.9 (H) Straight: 222.2 (L)×32 (W)×50 (H) Approximately 185g Approximately 235 g (cable not included) (cable not included) Frequency of pulse blow 5 Hz to 15 Hz * Indoors, altitude of 2000 m or less, pollution degree 2 (according to IEC61010-1) 0 - 40ºC 65% or less (Non-condensation) Green: indicates power/discharging; red: indicates abnormal display LED for lighting (white) Switch for LED lighting (3 positions) Always off/always on/synced to lever 0.04 ppm or less (when 200 mm from tip of nozzle, 0.2 MPa air pressure)* Main unit: PBT, nozzle: PPS 5. Wiring and Piping The ionizer generates ozone while exposed to the atmosphere. If you are using only one ionizer, the density will not saturate and rise above a set point. However, if multiple units are being used and you smell ozone, ventilate the area. Also, do not place your face near the nozzle of the ion air blower to confirm the smell of ozone. Your nose and throat could become sore. 1.4 Power supply voltage Temperature in usage environment Humidity in usage environment Indicators Lighting Switch for LED lighting Lock button Danger Do not use the product in excess of its specification range. Doing so creates the risk of product breakdown, loss of function, or damage. It could also drastically reduce the operating life. The tip of the discharge needle is sharp, so be careful when handling it. This could result in personal injury. Always supply compressed air before supplying electric power. Supplying electric power while no compressed air is supplied may result in a discharge that increases internal ozone density that produces a bad effect on the devices and environment. When using the product, do not point the nozzle at people, especially their face or eyes, etc. This could result in personal injury. Cables that are damaged by being bent excessively, pulled, rolled up, placed under heavy objects, or squeezed between two objects create the risk of current leaks or defective continuity that could result in fire, electric shock, or abnormal operation. Model number Ion production method Usage environment 4. Specifications Do not use in locations where explosives, flammables, or other dangerous substances are present. This product is not an explosion-proof type unit. Explosion or ignition may occur. When any wiring, installation, or inspection work is to be carried out, make sure that the unit is disconnected from the power supply, otherwise, an accident, an electrical shock or a malfunction may be caused. Never attempt to remodel the product. It could result in abnormal operation leading to injury, electric shock, fire, etc. Do not splash water on the product. Spraying it with water, washing it, or using it underwater could result in malfunction of the product leading to injury, electric shock, fire, etc. High voltages are applied to the discharge needle, so do not put it near electrically conductive materials, such as your fingers, body, wires, or tools. Doing so could result in electric shock or malfunction. 1.2 Specifications The product’s static charge elimination characteristics are shown below. (DTY-ELG41) *1 For DTY-ELG41 *2 Covered by label on DTY-ELG41. Power cable (2m) [When gun-shaped] [When straight] Figure1 Φ6 air fitting X904647 Ver.1.1 Electric Wiring/Air Piping Connect the main unit and the AC adaptor according to the wiring diagram below. Main circuit 24V Relay cable (3m/5m) Connectors AC adapter ②Check the electric wiring and air piping. ③Supply air that is being regulated by a regulator to the main unit. Be sure to set the pressure being applied to within the operating pressure range. ④Supply power (AC 100 V - 240 V, 50/60 Hz) to the AC adapter. ⑤Hold the main unit firmly, point the nozzle at the workpiece, and then squeeze the lever. Note) Do not grip the tip part of the main body, since it may effect on the ion balance. 0V F.G. Ground [Internal circuit] The power/discharge indicator LED (green) lights and ionized air sprays from the tip of the nozzle. To stop the ionized air, release your grip on the lever. The lever returns to its original position, the power/discharge indicator LED goes out, and the ionized air stops. Indicator Green Red State AC adapter AC100V-240V Air input (Φ6) Power cable (2m) To ground To air source Air tube (Φ6) (Power supply) · Connect the AC adapter connector to the power cable of the main unit. Insert the connector covers into each other so no dust gets inside. Energized state (power on) ◎⇒〇 〇 Lever on ● 〇 Discharge abnormality 〇 ● ●: ON 〇: Off Description When the power is turned on, the green LED flashes for 2 seconds, and then turns off. The lever is on, discharging is normal, green LED is lit. Discharge abnormality occurred while discharging. Red LED lights during abnormality. ◎: Flashing ⑦There is an LED for lighting on the end of the main unit. The LED for lighting is turned on/off according to the position of the lighting switch. Note) The AC adapter cable is not a flex resistant cable. If there is a risk of the cable moving, then secure the AC adapter cable or the connectors. The main unit cables and relay cable are flex resistant. The cable bending radius must be 32 mm or above. (Air) · Use clean air, from which oil and moisture have been removed, as the medium. · Attach the air tube (φ6-mm outer diameter) to the air fitting on the main unit. (Urethane tube recommended: Urethane tube/nylon tube) Note) The air tube length must be 3m or shorter. · Install a regulator between the air tube and the air source. · Do not excessively bend or twist the Φ6mm air tube near the fitting. Doing so may result in air leakage. When using nylon tubes, the minimum bending radius is 30mm. 6. Operations WARNING ● When using the product, do not point the nozzle at people, especially their face or eyes, etc. This could result in personal injury. ● Use protective glasses and ear plugs because there is a risk of noise causing hearing impairment or debris being blown into your eyes. Label ON LED for lighting (white) Always on OFF SYNC Always off Synced to lever On/off ⑧You can adjust the pulse frequency by turning the adjustment trimmer on the side of the main unit. Use a precision flathead screwdriver to adjust it. When using supported models: DTY-ELG41-PAU/DTY-ZPA-G31 Note) Squeeze the lever in a single motion. A pulse blow may not occur if you squeeze it slowly. Note) The trimmer increases frequency when turned counterclockwise and decreases when turned clockwise. The component parts of the trimmer may be damaged if you fully open or fully close it and then turn it further. Note) Piping conditions may cause variations in frequency characteristics and flow rate characteristics. Use a Φ6 air tube that is less than 3 m long. Replacing the in port/pulse blow unit Example) Replacing an in port (DTY-ZNP-G31) with a pulse blow unit (DTY-ZPA-G31) *Use the same procedure to replace the pulse blow unit with an in port. ①Remove the screws on the side of the main unit. To remove the cover, lift it in the direction of the arrow. Lock button Lock button WARNING ● Always turn off the air and the power before doing maintenance work. This can lead to malfunction or accident. ● The tip of the discharge needle is sharp, so be careful when removing and cleaning it. CAUTION Dirt sticking to the discharge needle reduces the static charge removal performance. Clean it periodically, or when the static charge removal performance is low. Cleaning method Rotate the nozzle to remove it from the main unit, then use a cloth or cotton swab dampened with alcohol (IPA) to clean the discharge needle (tip) and surrounding area inside the main unit. Allow it to dry completely, and then securely install the nozzle. How to replace the discharge needle The discharge needle is a consumable part that needs to be replaced. When replacing the discharge needle (5 piece set: DTRY-ZEM-G31), always use a combination of the specialized tool (DTRYELB21) and a torque screwdriver, and set the tightening torque to 15 to 20 N•cm for the replacement. If the torque is not appropriate, the screw in the main unit may be damaged. 8. Troubleshooting * Do not remove any other screws ②Lift the in port in the direction of arrow 1 to remove it in the direction of arrow 2 from the semi-circle area. Peel off the label that is on the pulse blow frequency adjustment trimmer. Arrow 1 Lock button 7. Maintenance Cover Screw Operations ①Press the lock button on the main unit to change to gun shape or straight. When gun-shaped, while pressing on the lock button, rotate the grip side 180 degrees in the direction of arrow 1 to switch to the straight shape, as shown in figure 2. When straight, while pressing on the lock button, rotate the grip side 180 degrees in the direction of arrow 2 to switch to the gun shape. After rotating, the lock button clicks so you can confirm it is locked. Always press the lock button all the way in when rotating. Rotating while the lock button is not pressed or in the opposite direction causes damage. If you changed from the in port to the pulse blow unit, then remove the label that is covering the frequency adjustment hole to use it. Toward + (counterclockwise): Frequency increases. Toward - (clockwise): Frequency decreases. CAUTION ● Do not drop or hit the air gun because there are piezoelectric ceramics inside it. ● The nozzle on the tip of the main unit is connected to internal circuits, so do not let it touch live wires or conductors. ● Use only the specified nozzle. Do not modify the nozzle. Otherwise, the product could break down, its functions could stop, or it could be damaged. ● If the power/discharge indicator LED (green) does not light or if the error indicator LED (red) lights, immediately turn off the power and refer to “5. Wiring and piping for installation” in this document. If the issue cannot be resolved, refer to “7. Maintenance” and “8. Troubleshooting” in this document. Note) If you changed from the pulse blow unit to the in port, then put the label provided on the pulse blow adjustment trimmer, which is on the side of the main unit. ● Fully ventilate the area when using alcohol, etc. Also, after cleaning with alcohol, allow the main unit to fully dry, and check that it is not wet. ● Never use a wire brush to clean the main unit, doing so could damage it. ● When installing a nozzle, tighten it by hand until there is no looseness. Do not overtighten it. Also, do not use any tools to tighten it. Switch position · Connect the ground cable (green wire). Note) 0V (AC adapter output) and F.G. (frame ground wire) are connected inside the main unit. Static charge removal performance is reduced when not fully grounded. · Connect the AC adapter to the power supply (AC 100 V - 240 V, 50/60 Hz). · When using the relay cable, connect it between the AC adapter connector and the power cable of the main unit. ④Confirm that it is fully in the semi-circle, and then close the cover. If you cannot close the cover at this point, the pulse blow unit may not be inside the semi-circle, so put it in again. Fasten the cover with the screw. (The main unit may be damaged if the correct tightening torque of 15 to 20 N・cm is not used.) In port Symptom Major cause Power does not turn on Power supply is not connected Air does not come out Air supply is not connected Discharge needle is dirty Discharge needle short circuit Nozzle is grounded Nozzle is loose Discharge needle is dirty or damaged Error indicator (red) is on Static charge is not eliminated Countermeasure Check whether the AC adapter is connected to a power supply. Check whether the main unit and AC adapter connectors are disconnected. Check whether compressed air is being supplied. Clean the discharge needle (tip) and the area around the discharge needle. Check whether there is a conductive object near the discharge needle. Do not allow the nozzle to be grounded. Tighten the nozzle securely to the main unit. Refer to “7. Maintenance” in this document to replace or do maintenance on the discharge needle. Semicircle ③Align the protruding tip of the pulse blow unit with the insertion hole on the main unit, and press it in, in the direction of arrow 3. While pressing in, press down in the direction of arrow 4, and put it into the semi-circle area. Insertion hole * Before using the product, refer to the “Safety Precautions (Common to All Ionizers) and Handling Instructions and Precautions (Common Precautions)” in the Static Electricity Removal Unit Ionizers catalog and on our website, regarding precautions for and how to use the product. * For inquiries about the product, contact our Overseas Department noted below. Arrow 4 Arrow 2 Arrow 1 Figure 2 Semicircle X904647 Ver.1.1 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- High-voltage air blower
- Static charge elimination
- Adjustable pulse frequency
- Gun-shaped or straight design
- LED lighting
- Ozone generation
- Clean air usage
- AC adapter included
- Discharge needle replacement
- Safety features
Frequently asked questions
The operating air pressure range for the DTY-ELG41 is 0.05 - 0.6MPa.
You can adjust the pulse frequency by turning the adjustment trimmer on the side of the main unit. Use a precision flathead screwdriver to adjust it. Turning the trimmer counterclockwise increases frequency, while turning it clockwise decreases frequency.
You should use clean air, from which oil and moisture have been removed. Using air that contains water or oil could result in the nozzle and interior of the main unit becoming dirty, the static discharge performance falling, or the main unit deteriorating.
When replacing the discharge needle, always use a combination of the specialized tool (DTRY-ELB21) and a torque screwdriver, and set the tightening torque to 15 to 20 N•cm. If the torque is not appropriate, the screw in the main unit may be damaged.
If the error indicator LED (red) lights up, immediately turn off the power and refer to the “5. Wiring and piping for installation” section in the manual. If the issue cannot be resolved, refer to “7. Maintenance” and “8. Troubleshooting” in the manual.