Instruction Manual
● Insert the 24VDC output connector of the AC adapter into the power supply signal
Appearance
connector on the backside of the main unit.
● The internal relay contacts will generate output signals as follows. The output signals
are rated for a maximum current of 50 mA and 24 V DC.
Wide Area Fan Type Ionizer
【DTY-FA01】
Output signal
OPEN
CLOSE
OPEN
relay contact
Note1: The relay contacts will generate output signals when ‘P.D.’ or ‘O.C.’ indicator (red LED) light up.
● Insert the 24VDC output connector of the AC adapter into the power and signal
Thank you very much for your purchase of DTY-FA01. Although this product is not classified
as a high-voltage device under any electrical equipment standard, it uses a high voltage.
Please read this manual diligently to carefully and correctly handle this unit. Keep this manual
on hand for your reference and consult it repeatedly as required.
<Wiring for AC adapter>
CAUTION
This product has a high-voltage generating device built in. Keep it away from
areas where water or oil can get on it, and do not locate it in areas that are
subjected to high temperatures and humidity. In particular, do not use this
product in areas subjected to high humidity and condensation.
Always be sure to ground the ionizer. Failure to do so can cause poor static
electricity removal and malfunction.
W hen the product is no longer usable or is no longer needed, dispose of it
appropriately as industrial waste.
Make sure to grasp the plug when removing the power cord. Pulling the
power cord by the cord may cause it to break, or become damaged and have
its core be exposed, which may cause a short circuit, or current leakage and
electrocution.
Be sure to perform wiring correctly. Incorrect or improper wiring can cause
malfunction.
For information about other precautions, refer to the “Safety Precautions”
section in the Static Electricity Removing Unit Io nizer catalog (Catalog No.
R0003-②).
Output signals connection wire
3. Specifications
Consumption current
Output voltage
Ion balance (NOTE1)
Static charge removal time (NOTE1)
DTY-FA01
Accessory AC adapter input: 100 V to 240V AC, 50/60Hz
(Output: 24V DC 2.1A)
24 V DC ± 5%
1A
±7,500 V o-papprox.
±5 V or less
Ambient temperature
1.0 sec. or less
OFF if abnormal high voltage output or fan locked
(red LED is lights up)
normally ON
MOS FET relay output
maximum allowed current: 50 mA
Applied voltage: 24 V DC or less
1.4 to 3.2 m 3/min × 2 fan
Vertically 360° variable (per 10 degree)
0.006 ppm or less
(at the center of the fan outlet [150 mm], at minimum flow rate)
0 to 40°C
Ambient humidity
Dimensions: (mm)
15 to 85% ( No condensation allowed )
370W×159H×78.5D (Main unit only)
Output signals
Airflow
Air flow out angle
Quantity of produced ozone
Weight
1.7 kg approx. (including bracket)
Instruction manual (this document), AC adapter (NOTE2),
Alarm output connection wire, Cleaning brush
Note1: Typical value at a distance of 300 mm from the center of the fan outlet, at maximum flow rate.
Note2: The power cable supplied with AC adapter is 125V rated power voltage.
Accessories
3
4
1
ALARM
ALARM
to User's circuits
Note1: The +24VDC wire, 0V DC wire and
GND wire are connected to the
connector before shipment.
(Viewed from AC adapter)
① ② ③
④
Connection the AC adapter
● Insert the power plug of the AC adapter to an AC (100 to 240V) power outlet (Connect
ON
OFF
POWER
RUN
FAN ADJ.
P.D.
O.C.
FAN LOCK
FAN SPEED
⑤ ⑥ ⑦
● Indication/ Function part description
Indication
No.
Name
Power supply
①
POWER
indicator
type
description
Lights up when the power supply is
green LED
turned ON.
Lights up when the product is
②
green LED
Run indicator
RUN
operated.
Fan speed
To enable change of airflow at
③
FAN ADJ.
screw
adjustment screw
step-less adjustment possible
The airflow can be indicated with
④
FAN SPEED
green LED
Fan speed indicator
the LED. [1 (weak) to 5 (strong)]
Lights up when an electrical
Pulse discharge
⑤
P.D.
red LED
discharge or a spark has occurred,
detection indicator
and High-voltage output is halted.
Lights up when an over-current has
Over Current
⑥
O.C.
red LED
occurred, and High-voltage output is halted.
detection indicator
Lights up when the fan is not in the
⑦
FAN LOCK
Fan lock indicator
red LED
normal operating status.
Note1: When P.D. or O.C. detection indicator is lights up, press the Power switch to cancel abnormal
status. But if the abnormal condition has not been removed, the abnormal status will occur
again.
to a grounded power outlet possibility).
● Make sure to use the AC adapter included with the product.
(INPUT: 100 V to 240 V 50/60 Hz, OUTPUT: 24 V DC)
● It takes approximately 5 seconds after the power is turned on before the fan
(1)
(2)
(3)
(4)
rotation stabilizes. To ensure proper static charge removal performance, do not
use the product until sufficient time has elapsed.
Turn the power switch of the product ON, and green POWER LED becomes light
up. The electrode becomes charged with high voltage, releases corona discharge,
and generates neutralizing ions. At the same time, the fans spin, and blow
neutralizing air from the front of the main unit. Charged materials placed in the
neutralizing air will be immediately neutralized.
The operating status is displayed on the front monitor panel. In a normal operating
state, only the green RUN LED lights up. If the fan stops, the red FAN LOCK LED
lights up, and if there is a high voltage output irregularity, the red P.D. LED or O.C.
LED lights up.
In accordance with the distance to the charged object, adjust the Fan speed
adjustment screw to provide the appropriate amount of airflow. Turn the Fan speed
adjustment screw gradually with phillips screwdriver.
Press the Power switch OFF to stop the product.
8. Indicator and Alarm output
4. I/O Circuit Diagram
RUN
[green]
○
LED state
P.D
O.C
[red]
[red]
Alarm output
ALARM
[1pin-4pin]
ON
OFF
OFF
OFF
OFF
FAN LOCK
[red]
○
○
○
Protrusion in the
engagement section
Note1: Turn the discharge needle unit until securely locked. The correct installation of the discharge
needle unit on the product is essential for the optimum operation of the product.
7. Operation
POWER
[green]
○
Normally
○
Pulse discharge
○
Over current
○
Fan lock
Power OFF
○
Cleaning the Filter
(1) Check that the power is turned off.
(2) While securely holding down the product in position, remove the filter cover. The
filter cover may be easily removed by gripping the side of the filter cover and pulling
it toward you.
(3) Clean the soiled and clogged the filter. If the filter is extremely dirty, wash it with
water (or a neutral detergent), and drying it thoroughly.
(4) Re-attach the filter to the product.
10. Troubleshooting
Problem
The power cannot
be supplied to
the product.
Main case
AC adapter not connected
Louver not installed
P.D. LED (red LED)
lights up.
Abnormal discharge
O.C. LED (red LED)
lights up.
Internal circuit is broken
FAN LOCK LED
(red LED) lights up
Fan in broken
Foreign objects
Remedy
Check to see if the AC plug is securely
inserted into the wall outlet.
Check the Louver to confirm that it is
correctly installed.
Check that the discharge needle is free
from conductive materials.
P.D. LED remains light even after the
discharge needle has been cleaned,
clean the area around the needle is dirty.
Check that the discharge needle unit to
confirm that it is correctly installed.
Turn off the power, and then turn the
power back on.
Check the filter is not dirty or blocked.
Check no foreign objects inside the
product.
※ If any other abnormal condition than above has been observed, immediately
turn OFF the power from the Product, and please contact the shop where you
purchased the Product (the agency), or the nearest service station of our
company.
9. Maintenance
Warning
● Before care and maintenance of the product, make sure to turn OFF the power.
Otherwise damage or operating problems may occur.
Note1: GND(#2) is connected internally to 0V(#3).
Note2: The 24VDC, 0V and GND wire are connected to the connector of the AC adapter before
shipment.
5. Installation
List of Specifications
6
0V
GND
● Indication/ Function part name
● This product uses two fans to blow air ionized with the corona discharge of an
electrode to eliminate the static electricity in electrically charged materials that are
located at a distance. The horizontal configuration of the product enables the
elimination of static over a wide range area.
● Includes output signals for abnormal high voltage or fan locked output (red indicator).
When abnormal high voltage occurs in this product, it stops the high voltage output.
● The front louver can be easily removed/attached for easy electrode maintenance. this
product also includes a safe circuit design that ensures that the high voltage output
and fans stop when the louver is removed.
● The amount and angle of the air blowing from the fan is adjustable.
24V DC
GND
2. Outline
Input voltage
(3) Prepare a new set of discharge needle unit.
(4) Align the protrusion on the product in the section to be engaged with the discharge
needle unit with the engaging section on the discharge needle unit. Press the
discharge needle unit into the product, so that both units will be engaged with each
other. Turn the discharge needle unit in the LOCK direction (counterclockwise) until
the discharge needle unit is securely locked with the product.
Viewed from AC adapter
This product is not designed to be explosion proof. Do not locate it or use it in
any location or environment where flammable gas or solvents are used.
Doing so creates the risk of fire and explosion.
High voltage is applied to the discharge needle. Keep your fingers and other
body parts, as well as wires, tools, and other conductive objects away from it.
Such conditions can cause electric shock and malfunction.
The tip of the discharge needle is a sharp point. Exercise sufficient care when
handling the needle.
Careless handling creates the risk of personal injury.
Never attempt to disassemble, repair, or modify the product in any way.
Doing so can cause accident or malfunction.
Be sure to turn off power before performing wiring, installation, or inspection
work. Failure to do so can cause accident, electric shock, or malfun ction.
For information about other warnings, refer to the “Safety Precautions”
section in the Static Electricity Removing Unit Io nizer catalog (Catalog No.
R0003-②).
Power-supply voltage
Discharge
Needle unit
connector on the backside of the Main Unit.
1. Safety Precautions
WARNING
Model No.
ALARM ON * Note1
(red LED light)
ALARM OFF
(no red LED lighting)
POWER OFF
Replacing the Discharge needle unit
(1) Remove the front louver.
(2) While securely holding down the product in place, remove the Discharge Needle
Unit by gripping the Finger Grip at the center of the Discharge Needle Unit and
turning it in the direction of FREE (clockwise), and releasing the Unit.
● Be sure to turn OFF the power before installing the product.
● Place the product on a level surface. If you want to fix the product to the surface, use
the screws already inside the holes, and make sure the product is secured firmly
before using it.
● The angle of the main unit may be adjusted per 10 degrees by loosening the Knob
Bolt. After the adjustment is completed, be sure to tighten the Knob Bolt again to
ensure that the angle of the main unit will stay unchanged.
6. Wiring
Caution
● When connecting to a grounded power outlet, use the 3-pin plug. When
connecting to an ungrounded (2-pin) power outlet using the adapter, be sure to
ground the lead “green” wire attached from the output connector of the AC
adapter. Otherwise, an electric shock accident or a malfunction of the unit may
occur. In addition, this product may not be able to work up to the full
performance.
Connection the Power Supply and the Output Signals
● Connect the Grounding Lead “green” wire attached from the output connector of the
AC adapter to the Grounding Point. If it is not securely grounded, the Product may not
be able to work up to the fullest performance.
● If the Alarm Output Signals are to be used, connect the “white” and “yellow” wires
(Accessories) to the output connector of the AC adapter. No polarity is involved with
the connections in this case. If no Alarm Output Signals are to be used, these wires
do not have to be connected to the connector of the AC adapter.
● The tip of the discharge needle is sharp, be careful not to touch the Discharge
Needle.
● When the product is used for long periods of time, the discharge needle and the air
inlet/ outlet section will get dirty. Clean the discharge needle and the air inlet/ outlet
section regularly, otherwise you could not get the desired effect, and operating errors
and accidents may occur.
● The maintenance required depends on the environment of use. As a reference,
cleaning both the discharge needle unit and fan filter should be done once 3,000
hours.
● The discharge needle is a part having a product life time. If the charge removal
performance is not restored after cleaning the discharge needle, it is recommended to
replace the entire discharge needle unit with a new one. The expected life span is
seemed to be 20,000 hours In case of natural wear and use.
● If you use the discharge needle unit or fan filter for replacement mentioned, please
purchase below.
・DTY-ZEM-FA : Discharge needle unit
・DTY-ZFR-FA : Fan filter (6 pcs.)
Cleaning the Front Louver
(1) Push in the tabs on both sides of the front
louver, and pull it towards yourself to remove it
from the product. Clean the louver using the
included cleaning brush. If the louver is
extremely dirty, wash it with water (or a neutral
detergent).
(2) Re-attach the front louver to the main unit after
drying it thoroughly.
Cleaning the Discharge needles
(1) Remove the front louver.
(2) Clean the discharge needles using the included
cleaning brush. If the discharge needles are
extremely dirty, it is recommended you add IPA
(isopropyl alcohol) to the cleaning brush.
1
2
1
JUST CONSULT US:
KOGANEI CORPORATION OVERSEAS DEPARTMENT
3-11-28, Midoricho, Koganei-shi, Tokyo, 184-8533, Japan
TEL:+81- 042-383-7271 FAX:+81- 042-383-7276
W ebsite: http://www.koganei.co.jp
The specifications or the appearance of this product are subject to change any
time without prior notice.
">