Instruction Manual
Appearance
Discharge
Needle unit
Over-Head Fan-Type ionizer
【DTY-HA01】
Thank you very much for your purchase of DTY-HA01. Although this product is not classified as a high-voltage device
under any electrical equipment standard, it uses a high voltage. Please read thi s manual diligently to carefully and
correctly handle this unit. Keep this manual on hand for your reference and consult it repeatedly as required.
(4) Prepare a new set of discharge needle unit.
(5) Align the protrusion on the Main Unit in the section to be engaged with the discharge needle unit with the
engaging section on the discharge needle unit. Press the discharge needle unit into the Main Unit, so that
both units will be engaged with each other. Turn the discharge needle unit in the LOCK direction
(counterclockwise) until the discharge needle unit is securely locked with the Main Unit.
1. Safety Precautions
WARNING
This product is not designed to be explosion proof. Do not locate it or use it in any location or
environment where flammable gas or solvents are used. Doing so creates the risk of fire and
explosion.
High voltage is applied to the discharge needle. Keep your fingers and other body parts, as well as
wires, tools, and other conductive objects away from it. Such conditions can cause electric shock and
malfunction.
The tip of the discharge needle is a sharp point. Exercise sufficient care when handling the needle.
Careless handling creates the risk of personal injury.
Never attempt to disassemble, repair, or modify the product in any way.
Doing so can cause accident or malfunction.
Be sure to turn off power before performing wiring, installation, or inspection work. Failure to do s o
can cause accident, electric shock, or malfunction.
For information about other warnings, refer to the “Safety Precautions” section in the Static Electricity
Removing Unit Ionizer catalog (Catalog No. R0003-②).
CAUTION
This product has a high-voltage generating device built in. Keep it away from areas where water or oil
can get on it, and do not locate it in areas that are subjected to high temperatures and humidity. In
particular, do not use this product in areas subjected to high humidity and condensation.
Always be sure to ground the ionizer. Failure to do so can cause poor static electricity removal and
malfunction.
W hen the product is no longer usable or is no longer needed, dispose of it appropr iately as industrial
waste.
Make sure to grasp the plug when removing the power cord. Pulling the power cord by the cord may
cause it to break, or become damaged and have its core be exposed, which may cause a short
circuit, or current leakage and electrocution.
Be sure to perform wiring correctly. Incorrect or improper wiring can cause malfunction.
This product has a high-voltage generating device built in. W hile power is being applied to the
product, keep metal objects away from the discharge needle to avoid abnormal discharge. Such
conditions can cause malfunction of or damage to the product and/or its peripherals.
This product cannot be used if the medium or ambient atmosphere includes any of the substances
below. Organic solvents, phosphate type hydraulic oil, sulfur dioxide gas, chlorine gas, or acids.
The life of the discharge needle depends on operating environment conditions. Periodic maintenanc e
is required because performance will deteriorate if the product is used in a bad operating environme nt
(high humidity, etc.) or if the discharge needle is not cleaned.
For information about other precautions, refer to the “Safety Precautions” section in the Static
Electricity Removing Unit Ionizer catalog (Catalog No. R0003-②).
2. Outline
● This product uses a fan to blow air ionized with the corona discharge of an electrode to eliminate the static
electricity in electrically charged materials that are located at a distance.
● This product is an overhead type requires no desk space, and can neutralize electricity over a large area.
● The high voltage output of the product are m onitored and displayed on a monitor panel.
● The front louver can be easily rem oved/attached for easy electrode maintenance. This product also includes
a safe circuit design that ensures that the high voltage output and fan stop when the louver is removed.
3. Specifications
List of Specifications
Model No.
Input voltage
Power consumption
Fuse
Output voltage
Ion balance (NOTE1)
Static charge removal time (NOTE1)
Display LED
Airflow
Quantity of produced ozone
Ambient temperature
Ambient humidity
Dimensions: (mm)
Weight
Accessories
DTY-HA01
100 V to 240V AC, 50/60Hz
42VA
1A
± 7,500 V o-p approx.
±10 V or less
4.0 sec. or less
Power: Green / High voltage alarm: Red
2.6 to 4.0 m3/min x 3fan
0.005 ppm or less
(at the center of the fan outlet [150 mm], at minimum flow rate)
0 to 40°C
15 to 85% ( No condensation allowed )
1020W×60.5H×150D (Main unit only)
5.0 kg approx.
Instruction manual (this document), Power cord, Cleaning brush
Note1: Typical value at a distance of 450 mm from the center of the fan outlet, at maximum flow rate.
Protrusion in the
engagement section
Note1: Turn the discharge needle unit until securely locked. The correct installation of the discharge needle unit on the Main Unit is
essential for the optimum operation of the Product.
4. Installation
● Make sure to turn the power of the product OFF before rem oving the power cord for installing the product.
● Using the fixing holes on both sides of the main unit, suspend it from the
ceiling with a chain. Alternatively, using bracket s, it is possible to install this
product in a variety of ways, such as on a shelf, vertically, or as a standing
type.
Note1: Install this device such that air flow is not obstructed.
5. Wiring
● Connect the power cord to main unit and insert the plug into an alternating
current (AC 100 to 240V) power outlet.
*This product is available with input voltage of AC100V - 240V. However, an
attached power cord is available with input voltage of AC100V only (less than
AC125V). If you use this product with input voltage of AC125V higher, prepare
another power cord which suited to input voltage.
● W hen connecting to a grounded power outlet, use the 3 -pin plug. W hen
connecting to an ungrounded (2 -pin) power outlet using the adapter
included with the product, be sure to ground the earth terminal. If it is not securely grounded, the product
may not be able to work up to the fullest performance.
6. Operation
(1) Turn the power switch of the product ON, and green POW ER LED becom es light up. The electrode
becomes charged with high voltage, releases corona discharge, and generates neutralizing ions. At the
same time, the fans spin, and blow neutralizing air from the front of the main unit. Charged materials placed
in the neutralizing air will be immediately neutralized .
(2) The flow of the neutralizing air can be adjusted using the air flow adjustment knob.
(3) The operating status is displayed on the front monitor panel. If there is a high voltage output irregularity, the
red H.V ALARM LED lights up.
(4) Turn the power switch OFF to stop the products.
7. Maintenance
● Before care and m aintenance of the product, make sure to turn the power of t he product OFF before
removing the power cord. Otherwise accidents or operating problems may occur.
● The tip of the discharge needle is sharp, be careful not to touch the discharge n eedle.
● W hen the product is used for long periods of time, the discharge needle and the air inlet/ outlet section will
get dirty. Clean the discharge needle and the air inlet / outlet section regularly, otherwise you could not get
the desired effect, and accidents and operating problems may occur.
● The maintenance required depends on the environment of use. As a reference, cleaning both the discharge
needle unit and fan filter should be done once 3,000 hours.
● The discharge needle is a part having a product life time. If the charge removal performance is not restored
after cleaning the discharge needle, it is recommended to replace the entire discharge needle unit with a
new one. The expected life span is seem ed to be 20,000 hours In case of natural wear and use.
● If you use the discharge needle unit or fan filter for replacement mentioned, please purchase below.
・DTY-ZEM-FA : Discharge needle unit
・DTY-ZFR-FA : Fan filter (6 pcs.)
Cleaning the Front Louver
(1) Push in the tabs on both sides of the front louver, and pull it towards
yourself to rem ove it from the main unit. Clean the louver using the
included cleaning brush. If the louver is extremely dirty, wash it with
water (or a neutral detergent).
(2) Re-attach the front louver to the main unit after drying it thoroughly.
Cleaning the Discharge needles
(1) Remove the front louver.
(2) Clean the discharge needles using the included cleaning brush. If the
discharge needles are extrem ely dirty, it is recommended you add IPA
(isopropyl alcohol) to the cleaning brush.
Replacing the Discharge needle unit
(1) Remove the power cord and move the m ain unit to the horizontal place.
(2) Remove the front louver.
(3) W hile securely holding down the Main Unit in place, remove the Discharge Needle Unit by gripping the
Finger Grip at the center of the Discharge Needle Unit and turning it in the direction of FR EE (clockwise),
and releasing the Unit.
Cleaning the Filter
(1) Check that the power is turned OFF.
(2) W hile securely holding down the main unit in position, remove the filter
cover. The filter cover m ay be easily rem oved by gripping the side of the
filter cover and pulling it.
(3) Clean the soiled and clogged the filter. If the filter is extrem ely dirty, wash it
with water (or a neutral detergent), and drying it thoroughly.
(4) Re-attach the filter to the main unit.
8. Troubleshooting
Problem
The power cannot
be supplied to the
product.
H.V. ALARM LED
(red LED)
lights up.
Main case
Power cord not connected
Louver not installed
Abnormal discharge
Internal circuit is broken
Remedy
Check to see if the AC plug is securely inserted into the product and
the wall outlet.
Check the Louver to confirm that it is correctly installed.
Check that the discharge needle is free from conductive materials.
Clean the discharge needle. But H.V. ALARM LED remains light
even after the discharge needle has been cleaned, clean the area
around the needle is dirty.
Check that the discharge needle unit to confirm that it is correctly
installed.
Turn off the power, and then turn the power back on.
※If any other abnormal condition than above has been observed, immediately turn OFF the power from the
Product, and please contact the shop where you p urchased the Product (the agency), or the nearest service
station of our company.
JUST CONSULT US:
KOGANEI CORPORATION OVERSEAS DEPARTMENT
3-11-28, Midoricho, Koganei-shi, Tokyo, 184-8533, Japan
TEL:+81- 042-383-7271 FAX:+81- 042-383-7276
W ebsite: http://www.koganei.co.jp
The specifications or the appearance of this product are subject to change any time without prior notice .
">