Koganei DTY-HA - HA Series Over head type is an overhead fan-type ionizer designed to eliminate static electricity in materials located at a distance. It uses a fan to blow ionized air, neutralizing static charge over a large area. The unit includes a high voltage output monitor, easily removable front louver for maintenance, and a safety circuit that stops high voltage output and fan operation when the louver is removed.

PDF Download
Document
Koganei DTY-HA - HA Series Over head type Instruction Manual | Manualzz

Advertisement

Advertisement

Advertisement

Key features

  • Overhead fan-type ionizer
  • Large area neutralization
  • High voltage output monitor
  • Removable louver for maintenance
  • Safety circuit

Frequently asked questions

The main unit can be suspended from the ceiling using a chain or installed on a shelf, vertically, or as a standing type using brackets. Ensure airflow is not obstructed.

The discharge needle and air inlet/outlet section should be cleaned regularly. As a reference, cleaning both the discharge needle unit and fan filter should be done once every 3,000 hours. If charge removal performance is not restored after cleaning the discharge needle, it is recommended to replace the entire discharge needle unit.

The red H.V. ALARM LED indicates a high voltage output irregularity. Check the discharge needle for conductive materials, clean the discharge needle, or ensure the discharge needle unit is correctly installed. If the problem persists, turn off the power and contact the shop where you purchased the product or the nearest service station.