Koganei Solenoid Valve F Series Owner's Manual
Koganei Solenoid Valve F Series is a versatile and reliable pneumatic valve designed for a wide range of industrial applications. This series offers both single and double solenoid configurations, allowing for flexible operation. It features a manual override button, enabling manual control of the valve position. The F Series also supports various piping configurations, including base piping and direct piping types, providing adaptability to different system requirements. The valve is equipped with dual-use fittings, enabling the connection of tubes with different diameters. The F Series is known for its durability, ease of use, and compatibility with various automation systems.
Advertisement
Advertisement
Y142171 Ver.8.0 Solenoid Valves F Series ●Switching from a double solenoid valve to a single solenoid valve ■Usable tubes ■General Precautions As shown in Fig.3, use a small screwdriver, etc. to push lightly against the manual override button, and then turn it by 90 degrees in the clockwise direction, so that the manual override button’s slit is in the vertical direction, and then attach the cover. Either a nylon or urethane tube can be used. Use tubes with an outer diameter tolerance within ± 0.1 mm of the nominal diameter, and ensure the ovalness (difference between the large diameter and small diameter) is 0.2 mm or less. (Using a Koganei tube is recommended.) Mounting 1. While any mounting direction is allowed, be sure to avoid strong Push lightly, then turn the manual overrride button clockwise to set as the single solenoid. Serial Transmission Compatible Manifold Manual override button Instruction Manual Ve r. 8.0 ■Single and double solenoid switching procedure (Except 3-position valves and tandem 3-port valves) By switching the manual override, model F□T1(2-position valve) can be used as either a single solenoid valve or a double solenoid valve (switching not possible with a 3-position valve and a tandem 3-port valve). Note that the F□T1 is set to the single solenoid specification at shipping. Figure 3 Cover (Back face) ●Switching from a single solenoid valve to a double solenoid valve 1.As shown in Fig.1, insert the flatblade edge of a small screwdriver into the gap between the valve and the cover, and then peel it off and remove the cover. ●Procedure for switching between the base piping type 4(A) port Fitting block and the direct piping type Double solenoid state Single solenoid state The manual override button is protruding. Caution: The cover has directionality (F15 and F18 series only). When attaching, always align the detent on the back of the cover with the manual override button’s slit, as shown in Fig.4. Figure 4 Cover End cover Caution: As shown in Fig.1, make sure to insert a small screwdriver from the side of the valve cover. The cover claw may be damaged when the cover is removed from the direction of the valve stem. Never remove the cover for any reason other than valve function switching. 2.As shown in Fig.2, use a small screwdriver, etc. to turn the manual override on the B side by 90 degrees in the counterclockwise direction, so that the manual override button’s slit is horizontal, as shown on the right side of the figure. Then the unit can be used as a double solenoid valve. When using it as a double solenoid valve, the button is used as the manual override button for the B side. Turn the manual override button in the counterclockwise direction to set as the double solenoid. B side manual override button Plate Figure 6 ※ Illustration shows the F10 series. Caution: 1. Always stop the air supply before operation. 2. Firmly tighten the screws after completing a re-combination. Recommended tightening torques are shown below. 3. Perform piping carefully in regards to the locations of each connection port (see Figs. 7, 8). 4. Care should be taken not to lose the gaskets while changing plates. N・cm Series Recommended tightening torque F10 17.6 Manual overrride F15 49.0 F18 49.0 For F10, F15 series When using models F□T1 or F□T2 (2-position valve) as double solenoid valves, caution should be exercised as energizing the A side solenoid or pushing the manual override button on the A side, while pushing the B side manual override button or in a locked state, or energizing the solenoid on the B side, will cause the valve to switch over the valve position. (At that time, the valve will operate in the same state as the single solenoid valve.) ■Dual use fittings (With dual use fitting blocks) The F series dual use fitting blocks employ dual use fittings for different tube sizes, which can connect tubes of 2 different outer diameters. (Excluding ports 1(P) and 3, 5(R) of F18 series.) Caution: 1. When using it as a double solenoid valve, do not attach the cover that was removed in Fig. 1. 2. Be aware that even if the valve has been switched to a double solenoid, no power will be supplied to the B side solenoid unless the valve base wiring is set to the double wiring A B A B A B A B A B 1. Use air for the media. For the use of any other media, consult us. 2. Air used for the cylinder should be clean air that contains no deteriorated compressor oil, etc. Install an air filter (filtration of 40 µm or less) near the valve to remove collected liquid or dust. In addition, drain the air filter periodically. 3. When supply pressure is low, use piping for the 1(P) port with sufficient tube size. 3, 5(R)port 1(P)port 4(A)port 2(B)port For F18 series A B A B A B A B Lubrication A B 4(A)port 1(P)port 2(B)port Note 3, 5(R)port ●Attaching and removing tubes When connecting tubes, insert an appropriate size tube until it contacts the tube stopper, and then lightly pull it to check the connection. For tube removal, push the tube against the tube stopper, then for large tube sizes, push on the release ring and at the same time pull the tube out. For small tube sizes, push on the outer ring by pressing the release ring and simultaneously pull the tube out (see Fig. 5). Release ring Note: Caution should be exercised that the positions of the 1(P) and 3, 5(R) ports are reversed from their positions in the F10 and F15 series. Figure 7 Port locations for F10, F15, F18 series are as shown in Fig. 8. 1(P)port 2(B)port 4(A)port 3, 5(R)port Figure 5 Large tube size Small tube size The product cannot be used when the media or ambient atmosphere contains any of the substances listed below. Organic solvents, phosphate ester type hydraulic oil, sulphur dioxide, chlorine gas, or acids, etc. ※ Diagram shows the F10 series. ●Attaching fittings to female thread blocks When attaching fittings to female thread blocks, secure with the tightening torques shown below or less. Screw size Tightening torque N・cm Rc1/8 686 Rc1/4 882 ※ For M5, tighten at the recommended torques for the fittings used. ●Attaching fittings to piping blocks〔 F18Z(G)-PM(P) 〕 Tube stopper Can be used without lubrication due to the factory lubricant (grease). When the pneumatic products require lubrication, use Turbine Oil Class 1 (ISO VG32) or the equivalent. In addition, cutting off oil feed while an operation is in progress could lead to malfunction due to the dissipation of the factory lubricant (grease). As a result, always keep the oil feed running continuously. However, use caution since excessive oil feed can also be a cause of malfunction. Avoid using spindle oil or machine oil. Atmosphere ● Base piping type Outer ring Tube stopper Note ※ Diagram shows the F10 series. Figure 8 Release ring Single solenoid state Double solenoid state The manual override button is protruding. Media ● Direct piping type Caution: When attaching or removing tubes, always stop the air supply. Figure 2 Plate 2(B) port 4(A) port ■Precautions for use of the double solenoid ※ Illustration shows the F10 series. 2(B) port Detent Claw Figure 1 could result in malfunction of the valve. If use in such conditions is unavoidable, always provide a cover or other adequate protective measures. ● Location directly exposed to water drops or oil drops ● Environment where a valve body is subject to dew condensation ● Location directly exposed to machining chips, dust, etc 3. In piping connection with valves, flush the tube completely (by blowing compressed air) before piping. Intrusion of machining chips or sealing tape, rust, etc., generated during plumbing could result in air leaks and other defective operations. 4. Never use the valve with the 4(A) and 2(B) ports vented to the atmosphere. 5. When mounting a valve inside a control panel, or when energizing time is long, make adequate consideration for ventilation and other heat dissipation measures. 6. When adding or subtracting units in the manifold, or replacing a fitting block, be sure to tighten to within the specified tightening torque range. ■Piping Base piping and direct piping can be switched by replacing the plate with a fitting block or a female thread block (see Fig. 6). Thank you for purchasing this Koganei product. Before using it, be sure to read this manual and make sure you use it correctly. shocks or vibrations applied directly to the body. 2. Avoid using in the locations and environment listed below, as it To attach fittings to the female thread type piping block of the F18 series, remove the piping block portion (the triangular-shaped block portion), screw the fittings into the 1(P) and 3, 5(R) ports while holding the piping block by applying a wrench to its metal portion. The tightening torque for the mounting (two M3 screws) of the piping block after the fittings have been attached should be 49.0 N・cm. ■Specifications of Serial Transmission Compatible Manifolds General Specifications Voltage 24VDC ±10% Operating temperature range 5〜50℃ Vibration resistance 49.0m/s2 Shock resistance 98.1m/s2 ●For details about specifications, see each user’s manual. ■ Serial Transmission Block, Terminal Block (LED) Part Names ● For OMRON CompoBus/S Transmission block specification: -31 (standard type), -32 (high-speed type) Transmission block specification: -A1 (16 outputs) ● For CC-Link ●EtherCAT Compliant ■Target Products for CE Marking Transmission block specification: -B1 (16 outputs) Transmission block specifications: -K1 (16 outputs), -K3 (32 outputs) The serial transmission block models which are listed below are complian to CE Marking. ●For CC-Link -B1(F10,F15 Series) ●For CC-Link -B3(F10,F15 Series) Dip switches for various settings Output selecting switch in faulty operation Dip switches for various settings PW L RUN L ERR. O N PWR ERR LOAD OFF HOLD PWR COMM ERR Communication connector (L/A OUT) RJ-45 (NC): Not used H/C: HOLD/CLEAR switch ×100 Power supply connector (4 contacts) Screw in type 45 6 901 78 23 BDL BS− FG 45 6 BS+ BDH 78 901 LED indicator 23 Indicator * For other details about specifications and precautions, see the catalog. * For inquiries about the product, contact the Koganei overseas department at the number below. Communication connector (L/A IN) RJ-45 Address setting switch 78 45 6 O N 0V 1 2 3 4 5 6 SIG (NC) H/C 23 ERR RD Sys.Run Sys.Rdy Run Er r L/A OUT L/A IN 901 24V O N SD 1 2 3 4 5 6 7 8 9 0 ● For OMRON B7A Link Terminal Description ×10 ×1 OVERSEAS DEPARTMENT 3-11-28, Midori-cho, Koganei City, Tokyo 184-8533, Japan Tel: 042-383-7271 Fax: 042-383-7276 24 ECAT ID G Indicator ● Connection method: 1 to 1 (Transmission block spec.) Standard type (-31) Max. 31 ms Transmission delay time Transmission distance Max. 500 m [1640 ft] High-speed type (-32) Max. 5 ms Max. 100 m [328 ft] PWR State Color Lights up Description Green Shuts off • Lights up when normal data is received from master station •Lights up during sending data Transmission block specification: -B3 (32 outputs) Transmission block specification: -D1 (16 outputs), -D3 (32 outputs) ×10 L ERR. •Lights up during receiving data • Lights up during transmission errors, and shuts off when time is over Lights up due to station number setting error or transmission speed setting error 8 Indicator State ※ Conforms to CC-Link. ● Number of outputs per block 16 solenoids (transmission block specification: -B1) ※ Since the block occupies 1 station, if remote I/O stations are entirely composed of the blocks, a maximum of 64 units can be connected to 1 master station. ● Related materials: User’s manual, document No.BK-HV041 ● F10 and F15 series are supported Sys.Run/Sys.Rdy Run Err L/A OUT L/A IN Flashing/flashing Green/yellow • Transmission block initialization Not lit/lit or flashing Green/yellow • Transmission block error Not lit/Not lit Green/yellow • Transmission block power OFF Off Green • INIT Flashing (blinking) Green • PRE-OPERATIONAL Flashing (single flash) Green • SAFE-OPERATIONAL Lighted Green • OPERATIONAL Off Red • No error Flashing (blinking) Red • Invalid setting Flashing (single flash) Red • Unrequested change in status Flashing (double flash) Red • Communication disconnect Lighted Green • Normal communication Flashing Green • EtherCAT frame sending/receiving Off Green • Not connected ●For CompoNet ● For CC-Link Transmission block specification: -B1 (16 outputs) Dip switches for various settings 4 ● 6 4 ● 6 O N 8 8 ● ● 4 6 ● 6 •Lights up during receiving data Shuts off • No power supply • Lights up during transmission errors, and shuts off when time is over Lights up due to station number setting error or transmission speed setting error Lights up • Communication connection completed Remarks ※ Conforms to CC-Link. ● Number of outputs per block 32 solenoids (transmission block specification: -B3) ※ Since the block occupies 1 station, if remote I/O stations are entirely composed of the blocks, a maximum of 64 units can be connected to 1 master station. ● Related materials: User’s manual, document No.BK-HV041 ● F10 and F15 series are supported NS Lights up Flashing Shuts off Green Red • Serious communication fault • Minor communication fault • No power supply Remarks ※Conforms to DeviceNet. ●Number of outputs per block A maximum of 16 solenoids (transmission block specification: -D1) A maximum of 32 solenoids (transmission block specification: -D3) ●Related materials: User’s manual, document No. BK-HV042 ● F10 and F15 series are supported NS 1 2 3 4 5 6 8 ● 8 ● ● BDL BS− 24G FG +24V (FG) SLD DG DB DA HOLD/CLEAR switch BS+ BDH BDL BS− • No communication connection 0 RD FG V+ Drain CAN H V− CAN L 0V 24V (FG) RD MS 8 O N ● •Lights up during sending data ● 1 2 3 4 5 6 7 8 9 0 4 SD Flashing • Minor breakdown 6 SD LED indicator Indicator PWR State Color Description Lights up Green • Normal state • Serious breakdown ● Red Flashing 4 Lights up • No setting state ● NS LED indicator Indicator 6 MS • Normal state ● Flashing Green Description 4 L RUN • Lights up when normal data is received from master station Lights up Color ● 6 •Lights up when power is turned on State 0 ● PW Indicator 0V ● ● Description 24V CLEAR 2 Indicator LED indicator HOLD ● MS ● 2 FG 0 ● 2 ● 0 ● ● STATION NO. ×1 ×10 ● 2 0 ● 0V B RATE PW L RUN L ERR. ● PWR COMM ERR HOLD/CLEAR switch SLD Transmission speed setting switch Station number setting switches ×1 BS+ BDH DB Number of solenoids for -K1 is 16 and for -K3 is 32. ● Related materials: User’s manual, document No. BK-HV044 ●F10 and F15 series are supported Transmission block specification: -A1 (16 outputs) NS 2 24V DG *EtherCAT compliant. ●Number of outputs for this block ● For OMRON CompoBus/S STATION NO. ● DA Remarks R ×10 L ERR. Description Green/yellow • Transmission block operation normal EtherCAT is a registered trademark and patented technology,licensed by Beckhoff Automation GmbH,Germany. Node address setting switches From left ×10, ×1 MS LED indicator Color Lit/Not lit Remarks Transmission block specification: -H1 (16 outputs) CLEAR RD RD ● ● 0 ● ● 8 ● ● 8 ● ● 0 2 ● ● 6 ● ● 0 SD 4 ● B RATE SD Dip switches for various settings ×1 2 L RUN L ERR. 2 PW 0V •Lights up when power is turned on ● For DeviceNet HOLD 24V PW L RUN ● For CC-Link Station number setting switches Description •Power not supplied •During normal communication Lights up Indicator 143129 LED indicator •During power supply COMM Yellow ※ For details of B7A Link Terminal, see the OMRON •Communication fault, or standby Shuts off catalog, user’s manual, etc. •Communication fault occurred Lights up ● Number of outputs per block ERR Red Maximum of 16 solenoids •During normal communication, or standby Shuts off ● Error output specifications Remarks Output type: NPN open collector ※ For details of CompoBus/S, see the OMRON catalog, Rated load voltage: 24VDC user’s manual, etc. Output current: Sink current MAX. 40 mA ● Related materials: User’s manual, document No. BK-HV038 ● Number of outputs per block 16 solenoids (transmission block specification: -A1) ● F10 , F15 and F18 series are supported ● Related materials: User’s manual, document No.BK-HV040 ● F10 and F15 series are supported Transmission speed setting switch SLD LED indicator YS7K1 (FG) LED indicator Remarks DB DA •Lights up when power is turned on •Lights up during faulty transmission 4 PWR ERR DG FG Lights up Red COMM • Serious breakdown Flashing Red • Minor breakdown Shuts off − • Power OFF/In preparation ERR State Lights up Shuts off Lights up Shuts off Lights up Shuts off LED indicator Color Green Yellow Red Description •During power supply •Power not supplied •During normal communication • Minor communication fault Shuts off − • Power OFF/In preparation Remarks ※Conforms to CompoNet. ●Number of outputs per block 16 solenoids (transmission block specification: -H1) ●Related materials: User’s manual, document No.BK-HV043 ※The communication connector is sold by Omron Corporation. Direct your inquiries to Omron. ● F10 , F15 and F18 series are supported L RUN • Lights up when normal data is received from master station •Communication fault occurred RD •Lights up during receiving data •During normal communication, or standby ※For details of CompoBus/S, see the OMRON catalog, user’s manual, etc. • Serious communication fault •Lights up when power is turned on •Lights up during sending data Remarks Red PW SD Flashing Green • Online/No-access state Flashing Description •Communication fault, or standby Lights up Green • Online/Access state Lights up Red Indicator ● Number of outputs per block 16 solenoids (transmission block specification: -A1) ● Related materials: User’s manual, document No.BK-HV040 ● F18 series are supported ● F10 and F15 series ( previous model) are supported L ERR. • Lights up during transmission errors, and shuts off when time is over Lights up due to station number setting error or transmission speed setting error Remarks ※Conforms to CC-Link. ● Number of outputs per block 16 solenoids (transmission block specification: -B1) ※Since the block occupies 1 station, if remote I/O stations are entirely composed of the blocks, a maximum of 64 units can be connected to 1 master station. ● Related materials: User’s manual, document No.BK-HV041 ● F18 series are supported ● F10 and F15 series (previous model) are supported ">
Advertisement
Key Features
- Single/Double Solenoid
- Manual Override
- Dual-Use Fittings
- Base/Direct Piping
- Various Tube Sizes
- Robust Construction
- Easy Installation