Koganei G010 - Solenoid valve G010 series Instruction manual
The Koganei G010 - Solenoid valve G010 series is a versatile device that allows for 2 or 3-port configurations, offering both normally closed (NC) and normally open (NO) functions. It can be used in both positive and negative pressure environments, and it is available in standard, low current, and large flow models to suit various applications. The G010 series features a manual override, LED indicator, and surge suppression for enhanced control and safety.
PDF
Download
Document
Advertisement
Advertisement
BK-UV002 Ver.1.0 Air Valve SOLENOID VALVES G010 SERIES INSTRUCTION MANUAL Ver.1.0 Handling Instructions and Precautions Piping Precautions Use the piping shown below for the manifold, as well. 2-, 3-port valves valve functions and connection port configurations Positive pressure specifications Normally open (NO) 2(A) 2(A) De-energized 1(P) 3(R) (plug) 2-port Normally closed (NC) Vacuum specifications Energized 1(P) (plug) 3(R) Normally closed (NC) 2(A) Normally open (NO) 2(A) 1(P) 3(R) 3-port 3-port 2-port De-energized 1(P) 3(R) Normally closed (NC) 2(A) Normally open (NO) 2(A) Normally closed (NC) 2(A) Normally open (NO) 2(A) Energized 1(P) (vacuum pump, etc.) 3(R) (plug) 1(P) (plug) 3(R) (vacuum pump, etc.) 1(P) (vacuum pump, etc.) (atmospheric air and 3(R) positive pressure) (atmospheric air and positive pressure) 3(R) (vacuum pump, etc.) 1(P) Caution: Normally closed (NC) and normally open (NO) valves cannot be mounted together on the same manifold. About the 2-, 3-port valves The G010 series can be divided, by the types of gaskets used on the valves, into 3-port and 2-port valves. When replacing the valve, pay attention to the gasket shape and mounting direction. G□010□E1 (For 3-port) G□010□E1-2 (For NC, 2-port) G□010□E1-2-11 (For NO, 2-port) 3(R) 2(A) 1(P) No hole in the 3(R) port section. Gasket has holes in three places. No hole in the 1(P) port section. Solenoid Manual override Plug connector Locking type Internal circuit <Standard type, low current type> ●DC5V, DC6V, DC12V, DC24V Solenoid with LED indicator (Surge suppression) ●Positive common LED indicator (Light Emitting Diode) Lead wire: Red(+) (COM) Lead wire: Black(−) LED indicator: Red ●Negative common (Made to order) Attaching and removing plug connector To lock the manual override, use a small screwdriver to push down on the manual override all the way and turn it clockwise. When locked, turning the manual override in the counterclockwise direction releases a spring on the manual override, returns it to the original position, and releases the lock. When the manual override is not turned, this type acts just like the non-locking type, the valve is energized as long as the manual override is pushed down, and it returns to the rest position upon release. Use fingers to insert the connector into the pin, push it in until the lever claw latches onto the protruded section of the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the protruded section of the connector housing, and pull it out. Connector housing Protruded section Pin LED indicator (Light Emitting Diode) Lever Lead wire: Red(+) RN TU (COM) Plug connector Lead wire: Black(−) Indication of polarity(DC) LED indicator: Red Contact ●AC100V, AC200V Solenoid with LED indicator (Surge suppression) H US P − Lead wire(AC) Yellow: AC100V White: AC200V C + Indication of polarity(DC) (COM) Crimping of connecting lead wire and contact Lead wire(AC) Yellow: AC100V White: AC200V <Large flow type> ●DC12V, DC24V Solenoid with LED indicator (Surge suppression) ●Positive common Lead wire: Red(+) Cautions: 1. Always release the lock of the locking type before commencing normal operation. 2. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. To crimp lead wires into contacts, strip off 4mm [0.16in.] of the insulation from the end of the lead wire, insert it into the contact, and crimp it. Be sure to avoid catching the insulation on the exposed wire crimping section. Insulation crimp tab Exposed wire crimping section Exposed wire 4mm Solenoid ia Timer circuit (COM) Contact Hook is Insulation (Maximum outer diameter:φ1.5) Lead wire: Black(−) Lead wire Applied wire AWG#24〜#30 LED indicator: Red ●Negative common (Made to order) Attaching and removing contact and connector Lead wire: Red(+) Solenoid (COM) ia Timer circuit is Lead wire: Black (−) LED indicator: Red ia: Starting current is: Steady-state current Operating principles of large flow type The large flow type uses a timer circuit, as shown above, that achieves power savings by switching to holding operations mode after a certain period of time to operate at about 1/3 of the starting power consumption. ●Power waveform Solenoid valves Power consumption ON OFF 3.2W Reduced power consumption 1.1W Start-up time Start-up time (Standard time) DC12V 48ms DC24V 27ms Cautions: 1. Do not apply megger between the lead wires. 2. The DC solenoid will not short circuit even if the wrong polarity is applied, but the valve will not operate. 3. Leakage current inside the circuit could result in failure of the solenoid valve to return, or in other erratic operation. Always use it within the range of the allowable leakage current. If circuit conditions, etc. cause the current leakage to exceed the maximum allowable leakage current, consult us. 4. The large flow type will not operate if the supply voltage is increased slowly. Always apply the appropriate voltage. Insert the contact with lead wire into a plug connector □ hole until the contact hook latches on the connector and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove it, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook, and then pull out the lead wire. Cautions: 1. Do not pull hard on the lead wire. It could result in defective contacts, shorted lines, etc. 2. If the pin is bent, use a small screwdriver, etc. to gently straighten out the pin, and then complete the connection to the plug connector. 3. For crimping of connecting lead wire and contact, always use a dedicated crimping tool. Contact: Model 706312-2MK Manufactured by Sumiko Tech, Inc. Crimping tool: Model F1 (for 706312-2MK) Manufactured by Sumiko Tech, Inc. Handling Instructions and Precautions Lead wire for common wiring (only lead wire) Common pre-wired lead wire assembly Using the lead wire for common wiring, provided as additional parts, saves wiring work. Using the common pre-wired lead wire assembly, provided as additional parts, saves wiring work. Order code Order code CR1652W − G010-COM Common specifications Blank Positive common M Negative common Lead wire length Blank 300mm [11.8in.] 1 1000mm [39in.] 3 3000mm [118in.] 1. Wiring example of DC positive side and AC common terminal (−) (−) (−) (−) (−) (−) COM(+) Outlet position of common wiring S The type PS is stn.1 side, the type PL is final stn. side. E The type PS is final stn. side, the type PL is stn.1 side. Lead wire for common wiring Number of wiring units 2:2 units 〜 20:20 units Connector Connector housing Common pre-wired lead wire assembly Shows polarity in DC case 2. Wiring example of DC negative side common terminal 1. For CR1652W–6E□ 2. For CR1652W–6E□M (+) (+) (+) (+) (+) (+) (−) (−) (−) (−) (−) (−) COM(+) COM(−) (+) (+) (+) (+) (+) (+) COM(−) Lead wire for common wiring Lead wire assembly for common wiring Lead wire assembly for common wiring Connector Connector Connector Connector housing 3. For CR1652W–6S□ 4. For CR1652W–6S□M (−)(−) (−) (−) (−) (−) Cautions: 1. The diagrams show the straight connector configuration. 2. Since the COM terminal is connected to a crossover terminal inside the connector housing, the connector cannot be switched between a positive common and a negative common wiring by changing the connectors. (+) (+) (+) (+) (+) (+) COM(+) COM(−) Lead wire assembly for common wiring Lead wire assembly for common wiring Connector Connector Caution: Since the COM terminal is connected to a crossover terminal inside the connector housing, the connector cannot be switched between a positive common and a negative common wiring by changing the connectors. Number of valves which can be energized simultaneously with common wiring DC5,6V E1 6 G010 LE1 12 HE1 − DC12V 12 20 4 DC24V 20 20 8 AC100V 20 − − AC200V 20 − − Model Voltage Fittings Recommended fittings G (V) 010□E1‐21 Connection port 2(A) port 1(P), 3(R) port TS4-M3M TS3-M3M TSH4-M3M TSH3-M3M TL4-M3M TL3-M3M ─ For urethane tube BF4BU-M3 BF3BU-M3 BF4BU-M3 BF3BU-M3 For nylon tube BF4-M3 BF4-M3 2(A) port 1(P), 3(R) port TS4-M5M TSH4-M5M TL4-M5M TLL4-M5M TS4-M5M TSH4-M5M TL4-M5M TLL4-M5M For urethane tube BF4BU BF3BU BF4BU BF3BU For nylon tube BF4 BF4 Fitting Quick fitting TAC fitting GA (V) 010□E1‐25 Connection port Fitting Quick fitting TAC fitting SOLENOID VALVES SERIES Specifications Basic Models and Functions G010E1(-11) GV010E1(-11) (standard) Item For A type manifold Note2 For direct piping, F type manifold Note1 Basic model G010LE1(-11) GV010LE1(-11) (low current) GA010E1(-11) GAV010E1(-11) (standard) G010HE1(-11) GV010HE1(-11) (large flow) Number of positions GA010LE1(-11) GAV010LE1(-11) (low current) GA010HE1(-11) GAV010HE1(-11) (large flow) 2 positions Number of ports 2, 3 ports Valve function Normally closed (NC, standard) or normally open (NO, option) Remark: For optional specifications and order code, see p. 45〜46. Notes: 1. When using the G010□E1, GV010□E1 as a single unit, select it with a mounting base. 2. When using the GA010□E1, GAV010□E1 as a single unit, select it with a sub-base. Specifications (Positive Pressure) Direct piping, F type manifold Basic model G010E1 (standard) Item G010LE1 (low current) A type manifold G010HE1 (large flow) GA010E1 (standard) Direct acting type Operation type Note 1 Effective area〔Cv〕 mm2 1 (P) →2 (A) 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 2 (A) →3 (R) 0.3〔0.017〕 0.2〔0.011〕 0.6〔0.033〕 0.3〔0.017〕 0.2〔0.011〕 0.6〔0.033〕 M3×0.5 Port size Note 2 M5×0.8 Not required Lubrication Operating pressure range 0〜0.7 {0〜7.1} [0〜102] MPa {kgf/cm 2} [psi.] 1.05 {10.7} [152] MPa {kgf/cm 2} [psi.] Response time Note3 ON/OFF ms Maximum operating frequency Hz 5/10 4/8 3/6 Shock resistance DC12V,DC24V AC100V, (AC200V) (DC5V,DC6V) (DC12V) DC12V,DC24V DC24V (DC5V,DC6V) DC12V,DC24V AC100V, (AC200V) Direct piping, F type manifold Basic model G010E1-11 (standard) Item G010LE1-11 (low current) DC24V GA010E1-11 (standard) GA010LE1-11 (low current) GA010HE1-11 (large flow) Air Direct acting type Operation type (A) →1 (P) Note 1 2 Effective area〔Cv〕 mm2 3 (R) →2 (A) 0.3〔0.017〕 0.15〔0.008〕 0.55〔0.031〕 0.3〔0.017〕 0.15〔0.008〕 0.55〔0.031〕 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 M3×0.5 Port size Note 2 M5×0.8 Not required Lubrication Operating pressure range MPa {kgf/cm 2} [psi.] 0〜0.7 {0〜7.1} [0〜102] 0〜0.5 {0〜5.1} [0〜73] Response time Note 3 ON/OFF ms Hz 0〜0.7 {0〜7.1} [0〜102] 0〜0.5 {0〜5.1} [0〜73] 1.05 {10.7} [152] MPa {kgf/cm 2} [psi.] Maximum operating frequency 4/8 5/10 3/6 4/8 5/10 3/6 (DC5V,DC6V) (DC12V) DC12V,DC24V DC24V 5 5〜50 [41〜122] Operating temp. range (atmosphere and media) °C [°F] Note4 1373.0 {140.0} (Axial direction 196.2 {20.0}) m/s2 {G} (DC5V,DC6V) DC12V,DC24V AC100V, (AC200V) Air supply port (DC12V) DC12V,DC24V A type manifold G010HE1-11 (large flow) Media Mounting direction (DC5V,DC6V) Any Mounting direction Rated voltage Note 5 3/6 5〜50 [41〜122] (DC5V,DC6V) Shock resistance 5/10 1373.0 {140.0} (Axial direction 196.2 {20.0}) m/s2 {G} Rated voltage Note 5 4/8 5 Operating temp. range (atmosphere and media) °C [°F] Note4 Proof pressure GA010HE1 (large flow) Air Media Proof pressure GA010LE1 (low current) (DC5V,DC6V) (DC12V) DC12V,DC24V DC24V (DC5V,DC6V) DC12V,DC24V AC100V, (AC200V) Any 3(R) port Notes: 1. For details, see the effective area on p.43. 2. For details, see the port size on p.43. 3. Values when air pressure is 0.5MPa {5.1kgf/cm2} [73psi.]. Due to switching phase timing, add a maximum of 5ms to the AC response time. 4. Provide heat radiation measures to ensure that the ambient temperature (or when used in a control box, the internal temperature of the box) always remains within the temperature range specifications. And for long-time continuous energizing, consult us. 5. Values in parentheses ( ) are for made to order items. See the corresponding table of solenoid options/voltage on p.50. Specifications (Vacuum) Basic model Direct piping, F type manifold GV010E1 (standard) Item GV010LE1 (low current) A type manifold GV010HE1 (large flow) GAV010E1 (standard) GAV010LE1 (low current) GAV010HE1 (large flow) Air Media Direct acting type Operation type Note 1 Effective area〔Cv〕 mm2 1 (P) →2 (A) 0.3〔0.017〕 0.15〔0.008〕 0.55〔0.031〕 0.3〔0.017〕 0.15〔0.008〕 0.55〔0.031〕 2 (A) →3 (R) 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 M3×0.5 Port sizeNote 2 M5×0.8 Not required Lubrication Operating pressure range MPa {kgf/cm2} [psi.] Proof pressure −100kPa〜0 {−750.1mmHg〜0} [−29.53in.Hg〜0] 1(P) port 3(R) port 0〜0.5 {0〜5.1} [0〜73] 0〜0.4 {0〜4.1} [0〜58] Response time Note 3 ON/OFF ms Maximum operating frequency Hz 5/10 4/8 3/6 4/8 5/10 3/6 (DC5V,DC6V) (DC12V) DC12V,DC24V DC24V 5〜50 [41〜122] 1373.0 {140.0} (Axial direction 196.2 {20.0}) m/s2 {G} (DC5V,DC6V) DC12V,DC24V Rated voltage Note 5 0〜0.4 {0〜4.1} [0〜58] 5 Operating temp. range (atmosphere and media) °C [°F] Note4 Shock resistance 0〜0.5 {0〜5.1} [0〜73] 1.05 {10.7} [152] MPa {kgf/cm 2} [psi.] AC100V, (AC200V) (DC5V,DC6V) (DC12V) DC12V,DC24V DC24V (DC5V,DC6V) DC12V,DC24V AC100V, (AC200V) Mounting direction Any Air supply port Vacuum 1(P) port Positive pressure 3(R) port Basic model Direct piping, F type manifold GV010E1-11 (standard) Item GV010LE1-11 (low current) A type manifold GV010HE1-11 (large flow) GAV010E1-11 (standard) GAV010LE1-11 (low current) GAV010HE1-11 (large flow) Air Media Direct acting type Operation type Note 1 Effective area〔Cv〕 mm2 2 (A) →1 (P) 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 0.2〔0.011〕 0.1〔0.006〕 0.45〔0.025〕 3 (R) →2 (A) 0.3〔0.017〕 0.2〔0.011〕 0.6〔0.033〕 0.3〔0.017〕 0.2〔0.011〕 0.6〔0.033〕 M3×0.5 Port sizeNote 2 M5×0.8 Not required Lubrication Operating pressure range MPa {kgf/cm2} [psi.] Proof pressure 1(P) port 0〜0.5 {0〜5.1} [0〜73] 0〜0.4 {0〜4.1} [0〜58] ms Maximum operating frequency Hz 5/10 4/8 3/6 5/10 3/6 (DC5V,DC6V) (DC12V) DC12V,DC24V DC24V 5〜50 [41〜122] 1373.0 {140.0} (Axial direction 196.2 {20.0}) m/s2 {G} (DC5V,DC6V) DC12V,DC24V Rated voltage Note 5 4/8 5 Operating temp. range (atmosphere and media) °C [°F] Note4 AC100V, (AC200V) (DC5V,DC6V) (DC12V) DC12V,DC24V DC24V Mounting direction Air supply port 0〜0.4 {0〜4.1} [0〜58] 1.05 {10.7} [152] MPa {kgf/cm 2} [psi.] Response time Note 3 ON/OFF Shock resistance 0〜0.5 {0〜5.1} [0〜73] −100kPa〜0 {−750.1mmHg〜0} [−29.53in.Hg〜0] 3(R) port (DC5V,DC6V) DC12V,DC24V AC100V, (AC200V) Any Vacuum 3(R) port Positive pressure 1(P) port Notes: 1. For details, see the effective area on p.43. 2. For details, see the port size on p.43. 3 Values when air pressure is 0.5MPa {5.1kgf/cm2} [73psi.]. Due to the switching phase timing, add a maximum of 5ms to the AC response time. 4. Provide heat radiation measures to ensure that the ambient temperature (or when used in a control box, the internal temperature of the box) always remains within the temperature range specifications. And for long-time continuous energizing, consult us. 5. Values in parentheses ( ) are for made to order items. See the corresponding table of solenoid options/voltage on p.50. Mass Solenoid Valve Mass g [oz.] Manifold Mass g [oz.] Basic model Mass Manifold model Mass calculation of each unit (n=number of units) Block-off plate G(V)010E1 14.6 [0.515] (16.8 [0.593])Note1 G010M□F (7×n) +9 [(0.247×n) +0.317] 1 [0.035] G(V)010LE1 14.6 [0.515] (16.8 [0.593])Note1 G010M□A (7×n) +9 [(0.247×n) +0.317] 1 [0.035] G(V)010HE1 15.3 [0.540] (17.5 [0.617])Note1 G010MH□F (7.2×n) +33 [(0.254×n) +1.164] 1 [0.035] GA(V)010E1 14.2 [0.501] (26.2 [0.924])Note2 G010MH□A (7.2×n) +33 [(0.254×n) +1.164] 1 [0.035] GA(V)010LE1 14.2 [0.501] (26.2 [0.924])Note2 GA(V)010HE1 14.8 [0.522] (26.8 [0.945])Note2 Notes: 1. Figures in parentheses ( ) are the mass with mounting base: -21. 2. Figures in parentheses ( ) are the mass with sub-base: -25. Solenoid Specifications Rated voltage DC5V DC6V DC12V DC24V 4.5〜5.5 (5±10%) 5.4〜6.6 (6±10%) 10.8〜13.2 (12±10%) 21.6〜26.4 (24±10%) 200 168 84 42 Item V G(A)(V)010LE1 G(A)(V)010E1 Operating voltage range Current (when rated voltage is applied) mA(r.m.s) 1.0W Power consumption 21 Starting mA 267 133 Holding mA 92 100 84 11 8 1.1VA 1.6VA 0.5W Power consumption Current (when rated voltage is applied) 1.0 mA Allowable leakage current G(A)(V)010HE1 180〜220 (200±10%) 1.0 42 Current (when rated voltage is applied) mA(r.m.s) AC200V Note 90〜110 (100±10%) 2.0 mA Allowable leakage current AC100V Note 46 Starting W Power consumption 3.2 Holding W 1.1 Allowable leakage current mA 10 5 Start-up time (standard time) ms 48 27 Over 100 MΩ Insulation resistance Grommet type: 300mm [11.8in.], Plug connector type: 300mm [11.8in.] Wiring type and lead wire length Red (+), Black (−) Color of lead wire Yellow White Red Color of LED indicator Flywheel diode Surge suppression (as standard) Bridge diode Note: Since the AC types have built-in bridge diodes, the starting current value and energizing current value are virtually the same. In addition, the rated frequencies are 50Hz and 60Hz. Specification values are the same for both. Effective Area〔Cv〕 mm 2 Standard (Single valve) Basic model Remarks G010E1(-11) ( 1 P) →2 (A)0.2 〔0.011〕 ( 2 A) →3 (R)0.3 〔0.017〕 ( 2 A) →1 (P)0.3 〔0.017〕 ( 3 R) →2 (A)0.2 〔0.011〕 G010LE1(-11) 2 A) →1 (P)0.15〔0.008〕 ( 1 P) →2 (A)0.1〔0.006〕 ( 3 R) →2 (A)0.1〔0.006〕 ( 2 A) →3 (R)0.2〔0.011〕 ( G010HE1(-11) ( 1 P) →2 (A)0.45〔0.025〕 ( 2 A) →1 (P)0.55〔0.031〕 ( 2 A) →3 (R)0.6〔0.033〕 ( 3 R) →2 (A)0.45〔0.025〕 GV010E1(-11) 2 A) →1 (P)0.2〔0.011〕 ( 1 P) →2 (A)0.3〔0.017〕 ( 3 R) →2 (A)0.3〔0.017〕 ( 2 A) →3 (R)0.2〔0.011〕 ( GV010LE1(-11) 2 A) →1 (P)0.1〔0.006〕 ( 1 P) →2 (A)0.15〔0.008〕 ( 3 R) →2 (A)0.2〔0.011〕 ( 2 A) →3 (R)0.1〔0.006〕 ( GV010HE1(-11) 2 A) →1 (P)0.45〔0.025〕 ( 1 P) →2 (A)0.55〔0.031〕 ( 3 R) →2 (A)0.6〔0.033〕 ( 2 A) →3 (R)0.45〔0.025〕 ( GA010E1(-11) 2 A) →1 (P)0.3〔0.017〕 ( 1 P) →2 (A)0.2〔0.011〕 ( 3 R) →2 (A)0.2〔0.011〕 ( 2 A) →3 (R)0.3〔0.017〕 ( GA010LE1(-11) ( 1 P) →2 (A)0.1〔0.006〕 ( 2 A) →1 (P)0.15〔0.008〕 ( 2 A) →3 (R)0.2〔0.011〕 ( 3 R) →2 (A)0.1〔0.006〕 GA010HE1(-11) ( 1 P) →2 (A)0.45〔0.025〕 ( 2 A) →1 (P)0.55〔0.031〕 ( 2 A) →3 (R)0.6〔0.033〕 ( 3 R) →2 (A)0.45〔0.025〕 GAV010E1(-11) ( 1 P) →2 (A)0.3〔0.017〕 ( 2 A) →1 (P)0.2〔0.011〕 ( 2 A) →3 (R)0.2〔0.011〕 ( 3 R) →2 (A)0.3〔0.017〕 GAV010LE1(-11) ( 1 P) →2 (A)0.15〔0.008〕 ( 2 A) →1 (P)0.1〔0.006〕 ( 2 A) →3 (R)0.1〔0.006〕 ( 3 R) →2 (A)0.2〔0.011〕 GAV010HE1(-11) ( 1 P) →2 (A)0.55〔0.031〕 ( 2 A) →1 (P)0.45〔0.025〕 ( 2 A) →3 (R)0.45〔0.025〕 ( 3 R) →2 (A)0.6〔0.033〕 ● For the case with quick fitting TSH4M3M attached to the 1(P) and 2(A) ports on the mounting base. ● Same values as for the case with quick fitting TSH4-M3M attached to the 2(A) port on F type manifold. ● For the case with quick fitting TSH4M5M attached to the 1(P) and 2(A) ports on the mounting sub-base. Remark: Figures in parentheses ( ) are for the normally open (NO) type. Port Size Solenoid Valve Port Size (With Base) Basic model G(V)010E1- 21 G(V)010LE1- 21 G(V)010HE1- 21 GA(V)010E1- 25 GA(V)010LE1- 25 GA(V)010HE1- 25 Port ( 1 P) ,3 (R) ( 2 A) Location of piping ports Mounting base Valve Port size M3×0.5 Manifold Port Size Manifold model G010M□F M3×0.5 G010M□A 1(P),2(A),3(R) Sub-base M5×0.8 G010MH□F G010MH□A Port Location of piping ports Port size ( 1 P) ,3 (R) Manifold M5×0.8 ( 2 A) Valve M3×0.5 M5×0.8 ( 1 P) ,3 (R) ( 2 A) Manifold M3×0.5 ( 1 P) ,3 (R) Manifold Rc1/8 ( 2 A) Valve M3×0.5 ( 1 P) ,3 (R) ( 2 A) Manifold Rc1/8 M5×0.8 Flow Rate 1(P)→2(A) 〔3(R)→2(A)〕 0.5 0.4 0.3 0.3 0.2 0.1 0 0.2 0.1 G010E1〔-11〕 GA010E1〔-11〕 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 2 4 6 8 10121416182022242628 0.5 0.4 G010LE1〔-11〕 GA010LE1〔-11〕 2 4 Supply pressure 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0 G010E1〔-11〕 GA010E1〔-11〕 Valve outlet pressure Valve outlet pressure 0.7 0.3 0.3 0.2 0.2 0.1 0.1 2 G010LE1-11 GA010LE1-11 4 Supply pressure 0.5 0.6 0.4 0.5 0.4 0.3 0 2 4 6 8 10121416182022242628 0.7 0.2 0.1 0.1 2 4 Flow rate R/min (ANR) G010LE1 GA010LE1 6 0.6 0.4 0.5 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 8 10 12 14 16 18 Flow rate R/min (ANR) 0.5 0.5 0.4 0.4 0.3 0.2 0.1 0.3 0.2 0.1 G010HE1〔-11〕 GA010HE1〔-11〕 MPa 0.6 0.5 0.4 0.5 0.4 0.3 0.3 0.2 0.1 0 5 10 15 20 25 30 35 40 45 50 55 Flow rate R/min (ANR) Supply pressure MPa 0.7 MPa 0.6 0 8 10 12 14 16 18 0.7 0.6 G010HE1 GA010HE1 5 10 15 20 25 30 35 40 45 50 55 2(A)→1(P) Supply pressure MPa 0.7 MPa 0.2 0.7 0.5 Flow rate R/min (ANR) 0.6 0.3 6 MPa 0.6 1(P)→2(A) 〔3(R)→2(A)〕 MPa 0.7 MPa 0.4 0.4 0.3 2(A)→3(R) 0.6 0.5 0.6 0.5 0.4 0 8 10 12 14 16 18 0.7 0.5 Flow rate R/min (ANR) Flow rate R/min (ANR) 2(A)→3(R) 〔2(A)→1(P)〕 MPa 0.7 6 MPa 0.6 Supply pressure MPa 0.7 Valve outlet pressure 0.6 0.4 0.6 Valve outlet pressure 0.5 Valve outlet pressure Valve outlet pressure 0.7 0.6 Supply pressure MPa 0.7 MPa 0.7 MPa 0.6 2(A)→3(R) 2(A)→1(P) Supply pressure MPa 0.7 Valve outlet pressure Supply pressure Valve outlet pressure 1(P)→2(A) 〔3(R)→2(A)〕 MPa 0.7 0.2 0.1 G010HE1-11 GA010HE1-11 5 10 15 20 25 30 35 40 45 50 55 Flow rate R/min (ANR) Flow rate R/min (ANR) Note: 0.6MPa [73psi.] and 0.7MPa [102psi.] are not available for G010HE1-11, GA010HE1-11. 1MPa = 145psi., 1R/min = 0.0353ft.3/min. How to read the graph (for G□010E1, 1(P)→2(A)) When the supply pressure is 0.5MPa [73psi.] and flow rate is 10R/min [0.35ft.3/min.] (ANR), the valve outlet pressure becomes 0.39MPa [57psi.]. Figures in brackets〔 〕indicate the normally open (NO) type. Air Supply Time and Exhaust Time How to read the graph Exhaust time: Time required for chamber interior to convert from atmospheric pressure state to vacuum state. Air supply time: Time required for chamber interior to convert from –100kPa [–29.53in.Hg] to atmospheric pressure state. Measurement conditions Digital memory scope Pressure sensor q Primary tank (13.6R [0.480ft.3]) w q and w are quick fittings. TSH4-M5M Chamber GAV010E1-25 0.25R[0.0088ft.3] GAV010E1-11-25 GAV010LE1-25 0.5R [0.0177ft.3] GAV010LE1-11-25 1.0R [0.0353ft.3] GAV010HE1-25 GAV010HE1-11-25 GAV010E1 Air supply time GAV010E1-11 Exhaust time GAV010E1-11 Air supply time kPa −101.3 kPa −101.3 kPa −101.3 kPa −101.3 −76.0 −76.0 GAV010E1 Exhaust time −50.7 500cc 250cc −50.7 −25.3 −25.3 250cc −50.7 500cc 1 2 3 4 Time 500cc −50.7 250cc −25.3 −25.3 1000cc 1000cc 0 Vacuum 250cc 1000cc −76.0 −76.0 500cc Vacuum Vacuum Vacuum 1000cc 0 5 1 2 3 4 Time s 0 5 0 1 2 s 3 4 Time 5 1 2 3 4 Time s GAV010LE1 Exhaust time GAV010LE1 Air supply time GAV010LE1-11 Exhaust time GAV010LE1-11 Air supply time kPa −101.3 kPa −101.3 kPa −101.3 kPa −101.3 −76.0 −76.0 −76.0 −76.0 250cc −50.7 250cc −25.3 1 2 3 −50.7 250cc −25.3 −25.3 1000cc 1000cc 0 500cc 500cc 500cc −25.3 −50.7 Vacuum 250cc 1000cc 500cc Vacuum −50.7 Vacuum Vacuum 1000cc 4 Time 0 5 1 2 3 4 Time s 0 5 1 2 s 3 4 Time 0 5 1 2 3 4 Time s GAV010HE1 Exhaust time GAV010HE1 Air supply time GAV010HE1-11 Exhaust time GAV010HE1-11 Air supply time kPa −101.3 kPa −101.3 kPa −101.3 −76.0 −76.0 1000cc −50.7 500cc −25.3 −25.3 −76.0 500cc −50.7 Vacuum −50.7 1000cc Vacuum Vacuum Vacuum 250cc 250cc 500cc 1000cc −25.3 1000cc −50.7 500cc −25.3 250cc 250cc 0 1 2 3 Time –100kPa = –29.53in.Hg, 5 s kPa −101.3 −76.0 5 s 4 5 0 1 3 Time s 250cc = 0.0088ft.3, 2 500cc = 0.0177ft.3, 4 5 s 1000cc = 0.0353ft.3 0 1 2 3 Time 4 5 s 0 1 2 3 Time 4 5 s G010 Series Solenoid Valve Order Codes ■ 2-, 3-port valve ■ 2-, 3-port valve Number of ports ■ Mounting base 3-port Blank 2(A) Normally closed (NC) 1(P) 3(R) ■ Wiring type Without mounting base Without sub-base ● Lead wire length: 300mm [11.8in.] is standard. Grommet type with LED indicator Blank Blank -11 Normally open (NO) Blank Note: For the piping, see table on p.37. 2-port 2(A) ■ Sub-base Valve function With mounting base Blank Straight connector with LED indicator With sub-base 1(P) -2 -21 -25 ● Attached to a valve body at shipping. ●Attached to a valve body at shipping. -PS L connector with LED indicator Positive pressure -PL Positive pressure Vacuum Direct piping Vacuum Sub-base piping Basic model Voltage 2-, 3-port standard type G010E1 DC12V, DC24V, AC100V 2-, 3-port low current type G010LE1 DC12V, DC24V 2-, 3-port large flow type G010HE1 2-, 3-port standard type GV010E1 2-, 3-port low current type GV010LE1 DC12V, DC24V 2-, 3-port large flow type GV010HE1 DC24V 2-, 3-port standard type GA010E1 DC12V, DC24V, AC100V 2-, 3-port low current type GA010LE1 DC12V, DC24V 2-, 3-port large flow type GA010HE1 2-, 3-port standard type GAV010E1 2-, 3-port low current type GAV010LE1 DC12V, DC24V 2-, 3-port large flow type GAV010HE1 DC24V -11 Note 2 -2 -11 Note 2 -2 -PS -PL -21 Note 1 -PS -PL -25 Note 1 DC24V DC12V, DC24V, AC100V DC24V DC12V, DC24V, AC100V Notes: 1. If using the solenoid valve as a single unit, always select it either with mounting base or with sub-base. 2. Normally closed (NC) and normally open (NO) valves cannot be mounted togther on the same manifold. Made to Order (After the wiring order code, enter the codes below.) Straight connector with LED indicator Negative common L connector with LED indicator Negative common Lead wire length Voltage specifications ●G□010E1:DC5V, DC6V, AC200V ●G□010LE1:DC5V, DC6V -1L -3L -MS Straight connector with LED indicator Without connector, contact and lead wire Negative common -MSX -ML Straight connector with LED indicator Without connector, contact and lead wire Positive common -PSX ●G□010HE1:DC12V ● For plug connector ● Length -1L: 1000 [39in.] (mm) -3L: 3000 [118in.] ● For AC110V〜120V, AC220V〜240V specifications, consult us. L connector with LED indicator Without connector, contact and lead wire Negative common L connector with LED indicator Without connector, contact and lead wire Positive common Straight connector with LED indicator Connector, contact included. Without lead wire. Negative common -MLX -PLX -MSN Straight connector with LED indicator Connector, contact included. Without lead wire. Positive common -PSN L connector with LED indicator Connector, contact included. Without lead wire. Negative common L connector with LED indicator Connector, contact included. Without lead wire. Positive common -MLN -PLN G010 Series Manifold Order Codes ■ 2-, 3-port valve ■ 2-, 3-port valve ■ Wiring type Number of ports Valve function ● Lead wire length: 300mm [11.8in.] is standard. 3-port Blank Grommet type 2(A) 1(P) Normally closed (NC) 3(R) Blank -11 Normally open (NO) 2-port -PS Blank L connector with LED indicator Note: For the piping, see table on p.37. 2(A) Straight connector with LED indicator 1(P) -2 Manifold model Number of units Station P, R port (M5×0.8) type F G010M stn.□ ⁝ 2 ⁝ 20 stn.□ A P, R port (Rc1/8) type F G010MH stn.□ ⁝ 2 ⁝ 20 stn.□ A ●Valve mounting location from the left-hand side when facing the 2(A) port (□: 1〜20) Additional Parts (To be ordered separately) Mounting base G010-21 ● For direct piping (With gasket) Mounting base G010H-21 ● For direct piping. For G010HE1-11, GV010HE1 only (With gasket). Sub-base G010-25 ● For sub-base piping (With gasket) -PL Basic model Voltage -G010E1 DC12V, DC24V, AC100V -G010LE1 DC12V, DC24V -G010HE1 DC24V -GV010E1 DC12V, DC24V, AC100V -GV010LE1 DC12V, DC24V -GV010HE1 -GA010E1 -2 -11 -PS -PL DC24V DC12V, DC24V, AC100V -GA010LE1 DC12V, DC24V -GA010HE1 DC24V -GAV010E1 DC12V, DC24V, AC100V -GAV010LE1 DC12V, DC24V -GAV010HE1 DC24V -G010E1 DC12V, DC24V, AC100V -G010LE1 DC12V, DC24V -G010HE1 DC24V -GV010E1 DC12V, DC24V, AC100V -GV010LE1 DC12V, DC24V -GV010HE1 -2 -11 -GA010E1 -PS -PL DC24V DC12V, DC24V, AC100V -GA010LE1 DC12V, DC24V -GA010HE1 DC24V -GAV010E1 DC12V, DC24V, AC100V -GAV010LE1 DC12V, DC24V -GAV010HE1 DC24V ●Specify the valve type for each station. ●Enter -BP when closing a station with a block-off plate without mounting a valve. ●Normally closed (NC) and normally open (NO) valves cannot be mounted together on the same manifold. Lead wire for common wiring Common pre-wired lead wire assembly G010-COM CR1652W- □ ● For -PS, -PL, -MS, -ML (Set of 10 pcs.) ● For details, see p.39. Block-off plate G010-BP Operating Principles and Symbols 3-port Normally closed (NC) Spring holder Solenoid Manual override Poppet Flapper spring ( 2 A) Sealed cap ( 1 P) ( 3 R) Column Major Parts and Materials Normally open (NO) Materials Parts Body ( 2 A) ( 3 R) ( 1 P) ( 3 R) Body ( 1 P) Valve Plunger spring Overspring Plunger Base Poppet Manifold Plastic Poppet Synthetic rubber Plunger Column Magnetic stainless steel Base Aluminum alloy(anodized) Body Aluminum alloy(anodized) Block-off plate Plastic Seal Synthetic rubber Corresponding Table of Mounting Valve/Manifold Base piping ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● G010MH□A G010MH□F G010M□A ● ● ● ● ● ● ● ● ● ● ● ● -25 Standard Small flow Large flow Standard Small flow Large flow Standard Small flow Large flow Standard Small flow Large flow Applicable manifolds (Sub-base) 1.0W 0.5W 3.2W(1.1W)Note2 1.0W 0.5W 3.2W(1.1W)Note2 1.0W 0.5W 3.2W(1.1W)Note2 1.0W 0.5W 3.2W(1.1W)Note2 -21 G010E1 G010LE1 G010HE1 GV010E1 GV010LE1 GV010HE1 GA010E1 GA010LE1 GA010HE1 GAV010E1 GAV010LE1 GAV010HE1 (Mounting base) Flow rate -11 Note 1 Power (Normally open, NO) Basic model -2 Direct piping (2-port) Piping configuration Valve options G010M□F Valve specifications ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2(A) port (M3) M3 (M3) M5 1(P), 3(R) port M5 M5 Rc1/8 Rc1/8 ●: Selectable or mountable Notes: 1. Care should be taken when ordering, since the initial settings for the normally closed (NC) and normally open (NO) valves cannot be changed later on. Normally closed (NC) and normally open (NO) valves cannot be mounted together on the same manifold. 2. Values in parentheses ( ) in power column are for holding state. Dimensions of Direct Piping Solenoid Valve (mm) G010E1 7 G010E1(-11)-21 (DC5V, DC6V, DC12V, DC24, AC100V) G010LE1(-11)-21 G010HE1-21 GV010E1(-11)-21 GV010LE1(-11)-21 2-φ2.2 thru hole 4 GV010HE1-11-21 (300) (25.6) 6 LED indicator 19.6 10 32 1 8.5 10.25 7 15 2-M3×0.5 (Connection port) G010HE1-11-21 GV010HE1-21 3.9 (18.7) 6 6 18 ( 1 P) ( 3 R) (33) Manual override Mounting base (-21) M3×0.5 (2(A) port) 17.6 7 (DC24V) 4 2-φ2.2 thru hole (25.6) 6 (300) LED indicator 19.6 10 34 (20.7) 15 7 17.6 M3×0.5 (2(A) port) G010E1̲ 2 7 2-φ2.2 thru hole 4 (25.6) 6 LED indicator (300) 10 19.6 Manual override 2-M3×0.5 (Connection port) 7 M3×0.5 (2(A) port) 1 15 17.6 10.25 8.5 (17) 18 6 ( 3 R) 6 ( 1 P) 3.9 37 Mounting base (-21) (38) G010E1(-11)-21 (AC200V) GV010E1(-11)-21 1 2-M3×0.5 (Connection port) 12.25 10.5 5.9 6 H 8 3(R) 20 1(P) (35) Manual override Mounting base (-21) Dimensions of Sub-base Piping Solenoid Valve (mm) GA010E1 GA010E1(-11)-25 (DC5V, DC6V, DC12V, DC24V, AC100V) GA010LE1(-11)-25 GA010HE1-25 GAV010E1(-11)-25 GAV010LE1(-11)-25 GAV010HE1-11-25 LED indicator 10 2-M5×0.8 (Connection port) 2-φ3.4 thru hole (Mounting hole) 4 5.5 10 8 (3) 17 20 Sub-base (-25) (DC24V) (300) LED indicator 19.6 10 2-M5×0.8 (Connection port) 2-φ3.4 thru hole (Mounting hole) 17 20 GA010E12 (AC200V) (300) LED indicator 10 2-M5×0.8 (Connection port) 2-φ3.4 thru hole (Mounting hole) Manual override 8 (3) 17 20 13 5.5 7 15 Sub-base (-25) 10.25 8.5 4 (17) 9.5 20 ( 2 A) 11.5 12 37 M5×0.8 (Connection port) 4 19.6 ( 3 R) (33.6) 5.5 13 ( 3 R) 10 8 (3) Sub-base (-25) 14 ( 1 P) 34 10.5 5.5 7 15 GA010E1(-11)-25 GAV010E1(-11)-25 12.25 12 H ( 1 P) 2 11.5 5.5 Manual override 4 9.5 20 ( 2 A) (20.7) M5×0.8 (Connection port) 4 (33.6) 14 ( 3 R) 7 15 GA010HE1-11-25 GAV010HE1-25 ( 1 P) 32 8.5 12 (18.7) 9.5 20 ( 2 A) 11.5 5.5 Manual override 10.25 M5×0.8 (Connection port) 13 (300) 19.6 4 (33.6) 14 10 Dimensions of Connector (mm) Options G010E1PL ●Solenoid with straight connector (AC200V): -PS ●Solenoid with L connector (AC200V): -PL ●Solenoid with straight connector: -PS G010E1L2 G010E1PS G010E1P2 19.6 14 19.6 Made to order connectors are the same dimensions in the drawings. R R 14 (30.2) R (30.2) 19.6 Code Model (48.1) (Overall length of valve) (16.5) (To the bottom of the valve) 37 (Overall length of valve) 32 (To the bottom of the valve) (43.1) (Overall length of valve) (16.8) (To the bottom of the valve) 32 (Overall length of valve) 19.6 37 R (To the bottom of the valve) ●Solenoid with L connector: -PL R Blank 300 - 1L 1000 - 3L 3000 Corresponding Table of Solenoid Options/Voltage Connector specifications -PS -PL -MS -ML -PSX -PLX -MSX -MLX -PSN -PLN -MSN -MLN G(A)010LE1〔-11〕 G(A)V010LE1〔-11〕 (low current type) (grommet) G(A)010E1〔-11〕 G(A)V010E1〔-11〕 (standard type) Voltage specifications DC5V △ △ △ △ △ △ △ △ △ △ △ △ △ DC6V △ △ △ △ △ △ △ △ △ △ △ △ △ DC12V ● ● ● △ △ △ △ △ △ △ △ △ △ DC24V ● ● ● △ △ △ △ △ △ △ △ △ △ AC100V ● ● ● △ △ △ △ AC200V △ △ △ △ △ △ △ DC5V △ △ △ △ △ △ △ △ △ △ △ △ △ DC6V △ △ △ △ △ △ △ △ △ △ △ △ △ DC12V ● ● ● △ △ △ △ △ △ △ △ △ △ Blank Basic valve models DC24V ● ● ● △ △ △ △ △ △ △ △ △ △ G(A)010HE1〔-11〕 G(A)V010HE1〔-11〕 (large flow type) DC12V △ △ △ △ △ △ △ △ △ △ △ △ △ DC24V ● ● ● △ △ △ △ △ △ △ △ △ △ Lead wire length options same for all basic models -1L △ △ △ △ △ △ △ △ △ △ △ △ -3L △ △ △ △ △ △ △ △ △ △ △ △ ●: Standard specifications △: Made to order Dimensions of F Type Manifold (for Direct Piping with Positive Pressure Solenoid Valves) (mm) G010MF G010M□F (1(P), 3(R) port: M5×0.8) G010E1 For the piping, see the table on p.37. 2‐φ3.2 (Mounting hole) G010LE1-PS G010HE1-PL LED indicator 3 − 3.5 4.5 9 C + L ( 3 R) ( 1 P) 43.6 32.5 15.3 8.2 Block-off plate (-BP) ( 1 P) ( 3 R) 20 Manual override H P 4‐M5×0.8 (Both sides) With 2 plugs (3.5) L M3×0.5 (2(A) port) Stn.1 Unit dimensions L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― Stn.3 Stn.4 10.2 (Pitch) 14 Number of units 12 13 14 15 16 17 18 19 20 ― 44.2 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 Stn.2 12 33.6 Number of units 2 3 4 5 6 7 8 9 10 11 mm G010M□F (1(P), 3(R) port: M5×0.8) G010LE1-11 2‐φ3.2 (Mounting hole) G010E1-11-PS G010HE1-11-PL 4‐M5×0.8 (Both sides) 3 − L C + ( 3 R) ( 1 P) 32.5 45.1 (For HE1) 43.6 (For E1, LE1) Block-off plate (-BP) (1.5) 15.3 8.2 4.5 9 Manual override ( 1 P) ( 3 R) 20 LED indicator H 3.5 P (3.5) L M3×0.5 (A port) Stn.1 Unit dimensions L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― 14 Number of units 12 13 14 15 16 17 18 19 20 ― 33.6 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 12 44.2 Number of units 2 3 4 5 6 7 8 9 10 11 mm For optional wiring, see p.50. Stn.2 With 2 plugs Stn.3 Stn.4 10.2 (Pitch) Dimensions of F Type Manifold (for Direct Piping with Vacuum Solenoid Valves) (mm) G010M□F (1(P), 3(R) port: M5×0.8) GV010LE1 For the piping, see the table on p.37. 2‐φ3.2 (Mounting hole) GV010E1-PS GV010HE1-PL 3 − 4‐M5×0.8 (Both sides) L C + ( 3 R) ( 1 P) 32.5 45.1 (For HE1) 43.6 (For E1, LE1) Block-off plate (-BP) (1.5) 15.3 8.2 4.5 9 Manual override ( 1 P) ( 3 R) 20 LED indicator H 3.5 P With 2 plugs (3.5) L M3×0.5 (2(A) port) Stn.1 Unit dimensions L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― Stn.4 33.6 Number of units 12 13 14 15 16 17 18 19 20 ― Stn.3 10.2 (Pitch) 14 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 Stn.2 12 44.2 Number of units 2 3 4 5 6 7 8 9 10 11 mm G010MF G010M□F (1(P), 3(R) port: M5×0.8) GV010E1-11 GV010E1-11-PS 2‐φ3.2 (Mounting hole) GV010E1-11-PL LED indicator 3 − 3.5 4.5 9 C + ( 3 R) ( 1 P) 32.5 15.3 8.2 Block-off plate (-BP) ( 1 P) ( 3 R) 20 43.6 Manual override P 4‐M5×0.8 (Both sides) (3.5) L M3×0.5 (2(A) port) Stn.1 Unit dimensions L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― 33.6 Number of units 12 13 14 15 16 17 18 19 20 ― 14 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 12 44.2 Number of units 2 3 4 5 6 7 8 9 10 11 mm For optional wiring, see p.50. Stn.2 With 2 plugs Stn.3 Stn.4 10.2 (Pitch) Dimensions of F Type Manifold (for Direct Piping with Positive Pressure Solenoid Valves) (mm) G010MHF G010MH□F (1(P), 3(R) port: Rc1/8) G010E1 For the piping, see the table on p.37. G010LE1-PS 2‐φ3.2 (Mounting hole) G010HE1-PL LED indicator ( 3 R) 15.8 With 2 plugs (8.5) M3×0.5 (2(A) port) Stn.3 Stn.2 Stn.1 Stn.4 10.2 (Pitch) 17 15.2 34.8 P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― 45.4 L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― H P mm Number of units 12 13 14 15 16 17 18 19 20 ― ( 1 P) 36.8 8.5 29 23 P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 + L 4‐Rc1/8 (Both sides) Unit dimensions C ( 3 R) 9.2 − L 8.5 7.2 Number of units 2 3 4 5 6 7 8 9 10 11 ( 1 P) 47.9 Manual override Block-off plate (-BP) G010MH□F (1(P), 3(R) port: Rc1/8) G010HE1-11 G010HE1-11-PS 2‐φ3.2 (Mounting hole) G010HE1-11-PL LED indicator ( 3 R) 15.8 ( 1 P) 36.8 8.5 45.4 34.8 15.2 29 23 For optional wiring, see p.50. P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― 17 Stn.2 With 2 plugs (8.5) P Stn.1 L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― + M3×0.5 (2(A) port) mm Number of units 12 13 14 15 16 17 18 19 20 ― C H L 4‐Rc1/8 (Both sides) Unit dimensions P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 H ( 3 R) 9.2 − H 8.5 7.2 Number of units 2 3 4 5 6 7 8 9 10 11 ( 1 P) 47.9 Manual override Block-off plate (-BP) Stn.3 Stn.4 10.2 (Pitch) Dimensions of F type Manifold (for Direct Piping with Vacuum Solenoid Valves) (mm) G010MHF G010MH□F (1(P), 3(R) port: Rc1/8) GV010HE1 For the piping, see the table on p.37. GV010HE1-PS 2‐φ3.2 (Mounting hole) GV010HE1-PL LED indicator ( 3 R) 15.8 ( 1 P) 36.8 8.5 29 23 With 2 plugs (8.5) M3×0.5 (2(A) port) Stn.4 10.2 (Pitch) 15.2 34.8 P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― Stn.3 Stn.2 Stn.1 17 45.4 L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― + P mm Number of units 12 13 14 15 16 17 18 19 20 ― C H L 4‐Rc1/8 (Both sides) Unit dimensions P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 H ( 3 R) 9.2 − H 8.5 7.2 Number of units 2 3 4 5 6 7 8 9 10 11 ( 1 P) 47.9 Manual override Block-off plate (-BP) G010MH□F (1(P), 3(R) port: Rc1/8) GV010HE1-11 GV010HE1-11-PS 2‐φ3.2 (Mounting hole) GV010HE1-11-PL LED indicator ( 3 R) 15.8 15.2 34.8 45.4 P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― 17 For optional wiring, see p.50. Stn.2 With 2 plugs (8.5) P Stn.1 L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― H M3×0.5 (2(A) port) mm Number of units 12 13 14 15 16 17 18 19 20 ― ( 1 P) 36.8 8.5 29 23 P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 + L 4‐Rc1/8 (Both sides) Unit dimensions C H ( 3 R) 9.2 − H 8.5 7.2 Number of units 2 3 4 5 6 7 8 9 10 11 ( 1 P) 47.9 Manual override Block-off plate (-BP) Stn.3 Stn.4 10.2 (Pitch) Dimensions of A Type Manifold (for Manifold Piping with Positive Pressure Solenoid Valves) (mm) G010MA G010M□A (1(P), 3(R) port: M5×0.8) GA010E1 For the piping, see the table on p.37. 2‐φ3.2 (Mounting hole) GA010LE1-PS GA010HE1-PL LED indicator 3 − 3.5 4.5 9 Stn. 1 Stn. 2 With 2 plugs (3.5) Stn. 3 Stn. 4 ( 2 A) 5 P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― 14 L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― 33.6 mm Number of units 12 13 14 15 16 17 18 19 20 ― 44.2 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 H 10.2 (Pitch) 12 Number of units 2 3 4 5 6 7 8 9 10 11 + P L 4‐M5×0.8 (Both sides) Unit dimensions C L ( 3 R) ( 1 P) 32.5 8.2 15.3 Block-off plate (-BP) ( 1 P) ( 3 R) 20 43.6 Manual override M3×0.5 (Connection port) G010M□A (1(P), 3(R) port: M5×0.8) GA010LE1-11 2‐φ3.2 (Mounting hole) GA010E1-11-PS GA010HE1-11-PL 43.6 (For E1, LE1) (1.5) 4‐M5×0.8 (Both sides) 3 Block-off plate (-BP) − L P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― ( 2 A) 5 L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― 33.6 mm Number of units 12 13 14 15 16 17 18 19 20 ― 14 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 M3×0.5 (Connection port) For optional wiring, see p.50. Stn. 2 With 2 plugs (3.5) P L Stn. 1 44.2 Number of units 2 3 4 5 6 7 8 9 10 11 + H 3.5 12 Unit dimensions C ( 3 R) ( 1 P) 32.5 45.1 (For HE1) 8.2 15.3 4.5 9 Manual override ( 1 P) ( 3 R) 20 LED indicator Stn. 3 Stn. 4 10.2 (Pitch) Dimensions of A Type Manifold (for Manifold Piping with Vacuum Solenoid Valves) (mm) G010MA G010M□A (1(P), 3(R) port: M5×0.8) GAV010LE1 For the piping, see the table on p.37. 2‐φ3.2 (Mounting hole) GAV010E1-PS GAV010HE1-PL 43.6 (For E1, LE1) (1.5) 4‐M5×0.8 (Both sides) 3 Block-off plate (-BP) − L 3.5 Stn. 2 Stn. 3 Stn. 4 10.2 (Pitch) mm P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― ( 2 A) 5 L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― 14 Number of units 12 13 14 15 16 17 18 19 20 ― 33.6 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 With 2 plugs (3.5) P L Stn. 1 44.2 Number of units 2 3 4 5 6 7 8 9 10 11 + H 12 Unit dimensions C ( 3 R) ( 1 P) 32.5 45.1 (For HE1) 8.2 15.3 4.5 9 Manual override ( 1 P) ( 3 R) 20 LED indicator M3×0.5 (Connection port) G010M□A (1(P), 3(R) port: M5×0.8) GAV010E1-11 2‐φ3.2 (Mounting hole) GAV010E1-11-PS GAV010E1-11-PL LED indicator 3 − 3.5 4.5 9 Stn. 1 12 mm P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― ( 2 A) 5 L 136.2 146.4 156.6 166.8 177 187.2 197.4 207.6 217.8 ― 14 Number of units 12 13 14 15 16 17 18 19 20 ― 33.6 P L 34.2 27.2 44.4 37.4 54.6 47.6 64.8 57.8 68 75 85.2 78.2 95.4 88.4 105.6 98.6 115.8 108.8 119 126 44.2 Number of units 2 3 4 5 6 7 8 9 10 11 M3×0.5 (Connection port) For optional wiring, see p.50. + Stn. 2 With 2 plugs (3.5) P L 4‐M5×0.8 (Both sides) Unit dimensions C ( 3 R) ( 1 P) 32.5 8.2 15.3 Block-off plate (-BP) ( 1 P) ( 3 R) 20 43.6 Manual override Stn. 3 Stn. 4 10.2 (Pitch) Dimensions of A Type Manifold (for Manifold Piping with Positive Pressure Solenoid Valves) (mm) G010MHA G010MH□A (1(P), 3(R) port: Rc1/8) GA010E1 For the piping, see the table on p.37. 2‐φ3.2 (Mounting hole) GA010LE1-PS GA010HE1-PL ( 3 R) Stn. 1 mm L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― (8.5) Stn. 2 Stn. 3 Stn. 4 10.2 (Pitch) 17 ( 2 A) 5 15.2 Number of units 12 13 14 15 16 17 18 19 20 ― With 2 plugs L 45.4 P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 H 34.8 Number of units 2 3 4 5 6 7 8 9 10 11 + P 4‐Rc1/8 (Both sides) Unit dimensions C ( 1 P) 36.8 15.8 23 8.5 7.2 9.2 − L ( 3 R) 8.5 29 Manual override Block-off plate (-BP) ( 1 P) 47.9 LED indicator M5×0.8 (Connection port) G010MH□A (1(P), 3(R) port: Rc1/8) GA010HE1-11 2‐φ3.2 (Mounting hole) GA010HE1-11-PS GA010HE1-11-PL 15.8 ( 3 R) P Stn. 1 mm P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― ( 2 A) 5 L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― 15.2 Number of units 12 13 14 15 16 17 18 19 20 ― 34.8 P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 17 45.4 Number of units 2 3 4 5 6 7 8 9 10 11 For optional wiring, see p.50. + H M5×0.8 (Connection port) Stn. 2 With 2 plugs (8.5) L 4‐Rc1/8 (Both sides) Unit dimensions C ( 1 P) 36.8 8.5 H 8.5 7.2 9.2 − H ( 3 R) 23 29 Manual override Block-off plate (-BP) ( 1 P) 47.9 LED indicator Stn. 3 Stn. 4 10.2 (Pitch) Dimensions of A Type Manifold (for Manifold Piping with Vacuum Solenoid Valves) (mm) G010MHA G010MH□A (1(P), 3(R) port: Rc1/8) GAV010HE1 For the piping, see the table on p.37. 2‐φ3.2 (Mounting hole) GAV010HE1-PS GAV010HE1-PL 15.8 ( 3 R) P Stn. 1 P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― Stn. 2 Stn. 3 Stn. 4 ( 2 A) 5 L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― (8.5) 34.8 Number of units 12 13 14 15 16 17 18 19 20 ― With 2 plugs 10.2 (Pitch) 17 15.2 P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 mm 45.4 Number of units 2 3 4 5 6 7 8 9 10 11 + H L 4‐Rc1/8 (Both sides) Unit dimensions C ( 1 P) 36.8 8.5 H 8.5 7.2 9.2 − H ( 3 R) 23 29 Manual override Block-off plate (-BP) ( 1 P) 47.9 LED indicator M5×0.8 (Connection port) G010MH□A (1(P), 3(R) port: Rc1/8) GAV010HE1-11 2‐φ3.2 (Mounting hole) GAV010HE1-11-PS GAV010HE1-11-PL ( 2 A) 5 P 129.2 139.4 149.6 159.8 170 180.2 190.4 200.6 210.8 ― 15.2 L 146.2 156.4 166.6 176.8 187 197.2 207.4 217.6 227.8 ― 34.8 mm Number of units 12 13 14 15 16 17 18 19 20 ― For optional wiring, see p.50. H ( 3 R) 15.8 17 45.4 P L 44.2 27.2 54.4 37.4 64.6 47.6 74.8 57.8 68 85 95.2 78.2 105.4 88.4 115.6 98.6 125.8 108.8 119 136 + P Stn. 1 Number of units 2 3 4 5 6 7 8 9 10 11 C M5×0.8 (Connection port) Stn. 2 Plug (8.5) L 4‐Rc1/8 (Both sides) Unit dimensions H ( 1 P) 36.8 8.5 8.5 7.2 9.2 − H ( 3 R) 23 29 Manual override Block-off plate (-BP) ( 1 P) 47.9 LED indicator Stn. 3 Stn. 4 10.2 (Pitch) ">
Advertisement
Key features
- 2-port, 3-port
- NC, NO
- Positive, Negative
- Standard, Low Current, Large Flow
- Manual override
- LED indicator
- Surge suppression
Frequently asked questions
The G010E1 is the standard model, while the G010LE1 is the low current model. The low current model operates with lower power consumption and is suitable for applications where power conservation is important.
No, normally closed and normally open valves cannot be mounted together on the same manifold. See the manual for more information.
The G010 series can be connected using quick fittings, TAC fittings, and standard fittings. For a complete list of the compatible fittings, consult the table on page 37 of the manual.